9 a

LSEC A Global Energy Company I

July 1,1999 GDP 99-1021

)

Director, Division of Facilities and Security Office of Administration United States Nuclear Regulatory Commission Two White Flint North 11545 Rockville Pike Rockville, MD 20852-2738 Paducah Gaseous Diffusion Plant (PGDP)

Docket No. 70-7001 Summary of 10CFR95.57(b) Reports Pursuant to the reporting requirements of 10CFR95.57(b), enclosed is a copy of the Security incident log and associated information for the month of June 1999.

Any questions regarding this matter should be directed to Larry Jackson at (502) 441-6796.

Sincerely, Howard Pulley General Manager Paducah Gaseous Diffusion Plant

/'

Enclosures:

As Stated cc: NRC Document Control Desk

.y V NRC Region III f(\\

NRC Resident Inspector, PGDP

'k

\\

9907090153 990701 I

PDR ADOCK 07007001 I

PDR i

P.O. Box 1410, Paducah, KY 42001 f

Telephone 502-441-5803 Fax 502-441-5801 http://www.usec.com Omces in Livermore, CA Paducah, KY Portsmouth, OH Washington, DC

4 SECURITY INCIDENT LOG PAD EVENT ATR#

DESCRIPTION DATE REPORT #

PAD-1999-002 99-0191 SPO failed to turn in security key ring at end ofshift 1-15 99 PAD-1999-003 99-0240 Classified information placed on BPS by PORTS 1-18-99 PAD-1999-006 99-0521 Security event-classified matter presented to 2/1/99 uncleared personnel (1985/86 timeframe) via video (I hour report) and sent video to PORTS (end of Jan

99) and then ADC'd and determined that classified info was contained on video (24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> logable)

PAD-1999-007 99-0571 Unmarked document found in CAA that contained 2-3-99 CRD.

PAD-1939-008 99-0676 Unclassified computer with classE information 2-9-99 PAD-1999-010 99-0676 Retraction of PAD-1999-008 2-15-99 PAD 1999-015 99-1223 Classified information created and distributed on an 3-4-99 unclassifed computer system.

PAD-1999-018 99-1483 Uncleared Alberici employees not properly escorted 3-15-99 PAD 1999-019 99-1541 Uncleared Alberici employee not properly escorted 3-17-99 PAD-1999-021 99-1672 Classified information created on an unclassified 3-24-99

&l674 computer system and information was reproduced PAD-1999-025 99-2002 Uncleared Alberici employees not properly escorted 4-8-99 PAD-1999-033 99-2519 Uncleared Alberici employee not properly escorted 5-3-99 i

PAD-1999-035 99-2661 C-720 Seal Cage had exposed mechanical parts 5-7-99 PAD-1999-038 99-2848 Classified repository not checked at end of workday 5-18-99 PAD-1999-039 99-2993 Documents found that were not in the accountability 5-25-99 system.

PAD-1999-041 99-3314 Classified repository not checked at end of w'orkday 6-3-99 PAD-1999-042 Classified document (4 copies) stored outside CAA 6-7-99 99-3410

~

from 1993-8/4/97 PAD-1999-044 99.-3641 Obsolete Markings on Document 6-17-99 PAD-1999-046 99-3744 Classified storage container not properly marked 6-22-99 PAD-1999-047 99-3769 Classified storage container not properly marked 6-23-99 SECURITY INCIDENT LOG filename: APss Computer CAC300\\ security. doc

PAD EVENT ATR#

DESCRIPTION DATE REPORT #

PAD-1999-050

< 99-3887 Classified material not correctly marked as CRD 6-29-99 S

0 J

l 3

Filename: APSS Computer C:\\C300\\ security. doc l

)

UE.675 (Pg 1 OF 2)

(5 20'97)

PAGE 10F 2 NRC FORM 361C U. S. NUCLEAR REGULATORY CCMMISSION

^

(2 97)

GASEOUS DIFFUSION PLANT OPERATICNS CENTER EVENT NOTIFICATION WORKSHEET NRC OPERATIONS TELEPHONE NUMBER: PRIMARY - 301-816-5100/ BACKUP 1 - 301-951-0550/ BACKUP 2 - 301-415-0550 NRC OPERATIONS FAX NUMBER: 301-816-5151 HEPOHT TIME FACluiY NAME OF CALLER CALLBAC6 IELEPHONE NUMtlER Paducah Gaseous Diffusion Plant (502) 441-6211 EVENT TIME EVEN T OATE LOCATION CF EVENT (INCLUDE COUNTY ANO STATE)

PORTION OF PLANT AFFECTED 1545 CDT 6/3/99 PGCP - McCracken County, Kentucky C-331 EVENT CLA55 FICAfloNS EVENT TYPES INCiOENT REPORT 5 (SPECIFIC TO 76.120)

SITE AREA EMERGENCY X

GASEOUS OlFFUSiON 20 2201 LOSS /THEF T (a)(1)

CRITICAUTY/ SUM LOST AttRT PUEL CYCLE 20 2202 ACTUAUTHHEA TENEO tan 2)

ACTUARA ITEMP TED OVEREXPOSURE THEFT X

'*C' eNr sEeORr TaANSPORrATiCN 20 2202 ACTUAi/ THREATENED (b)

PROTECTIVE ACTION RELEASE PREVENTED TRANSPOR TA TlON EV EN T O THER (Specify) 21.21 OEFECT1 (cit 1)

UNPLANNED NONCoMPLtANCE CONTAMINATION INFORMAliON ONLY 1331 SAFEGUAROS EVENTS (c)(2)

SAFETY EQUIPMENT FAILURE

)(

O THER (Speedy)

CRITICAUTY CON TROL 4-HOUR (c)(J)

MEDICAL TREATMENT (RULLETIN 9101)

WITH CONTAMINATION Loggable Secunty Event CRITICALI rY CONTROL 24-NOUR tc)(4)

FIRE /EXPOUSiON (BULLENTIN 9101)

OTHER NON CFR REQUIREMENT NOTIFICATION Yes No WILL BE ANYTHING UNUSUAL OR NOT Yes (Explain oerow)

UNDERsTOo07 NRC RESiOEN T A

X No STATE (S)

X 010 ALL SYSTEMS FUNCTION AS NA Yes LOCAL x

REQUIRE 07 NA No (Emplain beew)

OTHER GOVERNMENT AGENCIES X

ADDITIONAL INFORMA riON ON BACK7 Yes ME0lA/ PRESS RELEASE X

X No l

EVENT DESCRIPTION (Conunued on separate sneet if necessary)

At 1545 CDT on 6/3/99, the Plant Shift Superintendent was notified that a security infraction had occurred at the C-331 building area

' ontrol room office area on 6/2/99. The security infraction occurred when the end of the workday check of 2 classified repositories in C-

' 331 was not performed and logged The classified repository was locked but the check was not performed This infraction was recognized by a C 331 employee who was checking the safe on 6/3/99. No compromise of classified information occurTed.

This event is reportable as 'any infractions, losses, compromises, or possible compromise of classified information or classified documents not falling within 10CFR95.57(af, it is being logged per 10CFR95.57(b) (Exemption).

The NRC site resident has been notrfied of this event.

l PGDP Problern Report No. ATR-99-3314; PGDP Event Report Nc. PAD-1999-041 Responsible Division: Operations l

NRC FORM 361C (2 Sr) 9

UE-675 (Pg 1 OF 2)

(3-20-97).

PAGE 10F 2 NRC FOHM 361C U. S. NUCLEAR REGULATORY COMM(SSION

^

(2-97)

GASEOUS DIFFUSION PLANT OPERATIONS CENTER g

EVENT NOTIFICATION WORKSHEET NRC OPERATIONS TELEPHONE NUMBER: PRIMARY - 301816-5100/8ACKUP 1 - 301951-0550/ BACKUP 2 - 301-415 0550 NRC OPERATIONS FAX NUMBER: 301816 5151 HEPOHT TIME F ACILITY NAMti OF CALLER CALLBACK TELEPHONE NUMBER Paducah Gaseous Diffusion Plant N/A (502) 441-6211 EVENT TIME EVENT oATE LOCATION OF EVENT pNCLUDE COUN TY ANO STATE)

PORTlON OF PLAN T AFFECTED 1110 CDT 6/7/99 PGDP - McCracken County, Kentucky C 710 EVEN T CLASSIFICA TION s EVENT TYPES INCIDENT REPORTS (SPECIFIC 70 16.1201 StTE AHEA EMEHGENCY x

GASEOUS CIFFusiON 20 2201 LOSS / THEFT ta)(1)

CRITICALITY / SUM LOS T ALERT FUEL CYCLE 20.2232 ACTUALTHREATENEO WX2)

AC TUALATTEMP TED OVEREXPOSURE THEFT X

INCIDENT REPOR T TRANSPORTA rlON 20.2202 ACTUAUTHREATENEO (D)

PROTECTIVE ACTION RELEASE PREVENTED TRANSPORTATION EVENT OTHER (Specify) 21.21 OEFECTl teg1)

UNPLANNEO NoNCCMPLIANCE CONTAMINATION INFORMATION ONLY 1311 SAFEGUARDS EVENTS (c)(2)

SAFETY EQUIPMENT FAILURE

)(

OTHER (Specity)

CRITICAU TY CON TROL 4-HOUR (c)(3)

MEDICAL TREATMENT (BULLETIN 91-01)

WITH CONTAMINATION Loggable Secunty Event cRITICAUTY CONTROL 24 NOUR (c)t4)

FIRE /EXPOLISION (BULLENTIN 91-01)

OTHER NON-CFR REOuiREMENT NOTIFICATION Yse i No WILT. BE ANYTHING UNUSUAL OR NOT Yes (Esplain Delow)

UNoERSTooo?

NRC RESloEN T X

X No STATE (S)

X Otra ALL SYSTEMS FUNCTION AS NA Yes LOCAL A

REQUIREo?

NA No (Exclain below)

OTHER GOVERNMENT AGENC1ES X

A006TIONAL INFORMATION ON BACK7 Yes I

MEQlA/ PRESS RELEASE X

X No EVENT DESCRIPTION (Conunued on separate sheetif necessary) w At 1211 CDT on 6/7/99, the Plant Shift Superintendent was notified that a security infraction had occurred involving unmarked 1 Confidential Restricted Data stored outside the Controlled Access Area. During a classification review on 6/7/99 it was discovered that 4 copies of an unmarked 1993 document contained confidential restricted data that had been prepared and stored outside Controlled Access Area from 1993 until 8/4/97. Document was transmitted to Records Management on 8/4/97 and stored in the C-710 vault which is inside the CAA. Document was immediately protected as classified upon discovery of containing CRD. No known compromise of classified information occurred.

This event is reportable as 'any infractions. losses, compromises, or possible compromise of classified information or classified documents not falling within 10CFR95.57(a)". It is being logged per 10CFR35.57(b).

Tha NRC site senior resident has been notified of this event.

PGDP Problem Report No. ATR-99-3410; PGDP Event Report No. PAD-1999-042 Responsible Division: Production Support NRC FORM 381C (2 9r)

)

r i

. - - ~ ~ ~

]

UE-675 (Pg i OF 2)

(5 20'.97)

PAGE1CF2 NHC FORM.NIC U S NUCLt:AR HEGULATORY COMMISSION (2 97)

GASEOUS OlFFUSION PLANT OPERATIONS CENTER EVENT NOTIFICATION WORKSHEET NRC OPERATIONS TELEPHONE NUMBER: PRIMARY - 301-816-5100/8ACKUP 1 - 301-951-0550/ BACKUP 2 - 301-415 0550 NRC OPERATIONS FAX NUMBER: 301816-5151 HtPORT TIMt; F AGiu lY NAME.0F CALLER CALLilACK TELEPHONE NUMtsER 617-9961899 Paducah Gaseous Diffusion Plant Thomas White (502)441-6211 EVEHT TIME EVEN T DATE LOCA TION OF EVEN T (INCLUDE COUN TY ANO STA TE)

PORTION OF PLANT AFFECTED 1420 6 17-99 PGDP - McCracken County Kentucky C-743 i

EVEN T CLASSIFICAT!ONS EVENT TYPE 5 INCIDENT REPORTS ISPECIFIC TO 16.120)

S6TE AREA EMERGENCY X

GASEOUS OlFFUSION 20.2201 LOSS /THEF T taitt)

CRITICAu roSUM LOS T ALERT FUEL CYCLE 20 2202 ACTUAU1HREATENED tan 2)

AC TUAVA TTEMP TED OVEREXPOSURE THEFT X

INCL ENT REPORT TRANSPORTATICN 20.2202 ACTUAL /THREA TENED (c)

PROTECTIVE ACTION RELEASE PREVENTED TRANSPORTAT60N EVENT O THER (Specty) 21.21 DEFECT /

(CHI)

UNPLANNEO NONCOMPLIANCE CONTAMINATION INFORMATION ONLY 13 11 SAFEGUARDS EVENIS (c42)

SAFETY EOulPMENT FAILURE y

O THER (Speaty)

CRITICAUTY CONTROL 4-HOUR (ch3)

ME0iCAL TREATMENT (BULLETIN 91.ol)

WITH CONTAMINATION Loggable Secunty Event CRITICAUTY CONTROL 24. HOUR (c)(4)

FIRE /EXPOuSION' (BULLENTIN 9101)

OTHER NON-CFR REOUIREMENT NO TIFICA TlON Yes No WILL BE ANYTHING UNUSUAL OR NOT Yes tExplain Deiow)

UNDERSTOOD 7 NRC RES10ENT X

No STATE (S)

A Ol0 ALL SYSTEMS FUNCTION AS NA Yes LOCAL X

REOUIRED7 NA No (Exotain teicw)

OTHER GOVERNMENT AGENCIES X

ACOlTIONAL INFORMATION ON BACK7 Yes MED14 PRESS RELEASE

^

X No EVENT DESCRIPTION (Conunued on separate sneet if necessary)

At 1430 on 617-99, the Plant Shift Supenntendent was notified that a secunty infraction had been identified in C-743. A document was manted restncted secunty information, dated 3/12/53. This marking was a classified marking at that time. The document had never been oeclassifieo or rsmarked Tha NRC residant inspector has been notified of this event.

PGDP Problem Report No. ATR 99-3641; PGDP Event Report No. PAD-1999-044 R:sponsible Division: Training NRC FORM 361C (2 97) 4

~

UE-675 (Pg 1 OF 2) i52097)

PAGE 10F 2 NRC FORM 361G U S. NUCLEAR REGULATORY COMMISSIOf 4 (2 97)

GASEOUS DIFFUSION PLANT OPERATIONS CENTER EVENT NOTIFICATION WORKSHEET 1

NRC OPERATIONS TELEPHONE NUMBER: PRIMARY - 301-816 5100/ BACKUP 1 - 301951-0550/ BACKUP 2 - 301-415-0550

{

NRC OPERATIONS FAX NUMBER: 301-816-5151 j

REPORT TIME FACIUIY NAME OF CALLER CALLBACK TELEPHONE NUMtaER 6 22 99/1745 CDT Paducah Gaseous Diffusion Plant N/A (502) 441-6211 I

EVENT TIME EVEN T DATE LOCATION OF EVEN T (INCLUDE COUNTY ANO STATE)

PORTION OF PLANT AFFECTED 1740 CDT 6 22-99 PGDP - McCracken County. Kentucky C 333 EVEN T CLASSIFICATIONS EVENf TYPES INCIDENT REPORTS (SPECIFIC TO 76.120)

Si1E AREA EMERGENCY K

GASEOUS Off FUSION 20 2201 LOSSrTHEFT (a)(1)

CRITICAUTY/ SUM LOST ALERT FUEL CYCLE 20 2202 ACTUAUTHREATENEO (a)t2)

ACTUAVATTEMPTED OVEREXPOSURE THEFT X

'NC' eNr REeORT TRANSPORTATION 20.2202 ACTUAUTHREA TENED (D)

PROTECTIVE ACTION RELEASE PREVENTED TRANSPORTATION EVENT OTHER (Specify) 21.21 DEFECTt (c)(1)

UNPLANNED NONCOMPUANCE CONTAMINATION INFORMATION ONLY 13.71 SAFEGUAROS EVENTS (c)(2)

SAFETY EQUIPMENT FAILURE K

OTHER (Spec 4fy)

CRITICAUTY CONTROL 4. HOUR (c)(3)

MEJ' CAL TREATMENT (BULLETIN 91-01)

WITH CONTAMINATION LoggaDie Secunty Event CRITICAUTY CONTROL 24-HOUR (c)(4)

FIREsEXPOUSION (BULLENTIN 91 ot)

OTHER NON-CFR REQUIREMEN!

NO TIFICA TION Yes No WILL BE ANYTHING UNUSUAL OR NO T Yes (Explain ceiow)

UNDERSTOOO7 NRC RESiOENT X

X No STATE (S)

X Ol0 ALL SYSTEMS FUNCTION AS NA Yes LOCAL X

REQUIRED 7 NA No (Exetain below)

OTHER GOVERNMENT AGENCIES X

ADDITIONAL INFORMATlON ON SACK?

Yes MEDIA / PRESS RELEASE X

X No EVENT DESCRIPTlON (Conunued on separate sneet if necessary)

At 1740 COT, on 6-22-99, the Plant Shift Superintendent's office was notrfied of an infraction of the Classified Matter Plart A storage container for classified parts was found in the C-333 classified storage area without markingt, required by the Classified Matter Protection Plan. The container was immediately marked as required by the plan and by procedure.

This event is reportable as "any infractions, losses, compromises, or possible compromise of classified information or classified documents not falling within 10CFR95.57(af, it is being logged per 10CFR95.57(b).

Ths NRC resident inspedor has been notified of this event.

PGDP Problem Report No. ATR 99-3744; PGDP Event Report No. PAD-1999 046 RIsponsible Division: Safety, Safeguards, & Quality (SS&Q)

NRC FORM 361C (2 97)

UE475 (Pg 1 CF 2) j (5-20 97)

PAGE 10F 2 l

NRC FORM 361C U S NUCLEAR REGULATORY COMMISSION (2-97)

GASEOUS DIFFUSION PLANT CPERATIONS CENTER EVENT NOTIFICATION WORKSHEET NRC OPERATIONS TELEPHONE NUMBER: PRIMARY - 301816 5100/ BACKUP 1 - 301951-0550/8ACKUP 2 - 301-415-0550 NRC OPERATIONS FAX NUMBER: 301-816,5151 REPORT TIME F ACiul'f NAME OF CALLER CALLBACK IELEPHONE NUMBER 6-23-99/2130 CDT Paducah Gaseous Diffusion Plant N/A (502) 441-6211 l

EVENT TIME EVEN T DATE LOCA flON OF EVEN T (INCLUCE COUNTY AND $ TATE)

PORTION OF Pt. ANT AFFECTED 1550 CDT 6-23-99 PGDP - MCCracken County. Kentucky C-333 tiVENT CLAssiFICA TIONS EVENT MPEs INCMEN T REPORTS (SPECIFIC TO 76.120)

G^66 "S

U8' N 2 220 LOSS <TnaT i )(i)

CairiCAu rYiSuu LOST SITE AREA EMERGENCY X

ALERT FUEL CYCLE 20 2202 ACTUAL /THNCATENED (a)(2)

ACTUAUATTEMPTED OVEREXPOSUM THEFT X

INCACEN T REPOR T TRANSPOR TA TION 20 2202 ACTUAUTHREA TENED (t)

PROTECTIVE ACTION RELEASE PREVENTED TRANSPORTAT60N EVENT OTHER (Speary) 21.21 DEFECT /

(c)(1)

UNPLANNED NONCOMPLIANCE CONTAMINATION INFORMAIlON ONLY 1311 SAF EGUARDS EVEN TS (c)(2)

SAFETY EQU4PMENT l

FAILURE i

X THER (SP' 'v)

C8)C^urY CONTROL 4 NOUR (c)(3)

MEO! CAL TREATMENT (BULLETIN 91 o1)

WITH CONTAMINATION Loggable Secunty Event CRITICAUTY CONTROL 24-NOUR (c)(4)

FIRE /EXPOUS40N j

(BULLENTIN 91 o1)

OTHER NON CFR REQUIREMENT I

NOTIFICATION Yes No WILL BE ANYTHING UNUSUAL OR NOI Yes (Explain Denv)

UNDERSTOOO?

NRC RES10EN T X

X No STA TE(S)

X 010 ALL SYSTEMS FUNCTION AS NA Yes LOCAL X

REQUIRED 7 NA No IExplain teov)

OTHER GOVERNMENT AGENCIES X

ADDITIONAL INFORMATlON ON BACH?

Yes MEDIA / PRESS RELEASE

^

X No EVENT DESCRIPTION (Conunued on separate sneet of necessary)

At 1550 CDT on 6-23-99, the Plant Shift Supenntendent's office was notified of an infraction of the Classified Matter Plan. A storage container for classified parts was found in the C-333 classified storage area without markings required by the Classified Matter Protection Pfan. The container had bGon moved into the storage area eartier in the day. The container was immediately marked as required by the plan and by procedure.

This event is reportable as 'any infractions, losses, compromises, or possible compromise of classified information or classified documents not falling within 10CFR95.57(a)*. It is being logged per 10CFR95.57(b).

The NRC resident inspector has been notified of this event.

PGDP Problem Report No. ATR-99-3769; PGDP Event Report No. PAD-1999 047 Responsible Division: Safety, Safeguards, & Quality (SS&Q)

NRC FORM 361C (2 97) l l

i j

UE-6Z5 (Pg 1 OF 2)

-(5-20 97)

PAGE1CF2 NRC FORM 361C U. S. NUCLEAR REGULATORY CCMMISSION (2 97)

GASEOUS DIFFUSION PLANT OPERATIONS CENTER EVENT NOTIFICATION WORKSHEET NRC OPERATIONS TELEPHONE NUMBER: PRIMARY - 301816-5100/ BACKUP 1 - 301-951-0550/8ACKUP 2 - 301-415-0550 NRC OPERATIONS FAX NUMBER: 301816-5151 HEPORJ TIME P ACILITY NAME OF CALLER CALLDACK TELEPHONE NUMBER 6 29-99/1211 CDT Paducah Gaseous Diffusion Plant N/A (502) 441-6211

&ENT T;ME EWN T OA TE LOCAIlCN OF EVEN T tlNCLUDE COUNTr ANO STATE)

PCRTICN OF PLANT AFFECTED 1000 CDT 6-29-99 PGDP - McCracken County, Kentucky C 743 EVENT CL.A55lFICATIONS EVENT TYPES INCIDENT REPORTS (SPECIFIC TO r6.12a)

SITE AREA EMERCENCY X

G^SeOus OiFFUSiON

o22ai LOSS < THEFT

(.>(i)

CRiTiCAuTY,Suu LOST ALERT FUEL CYCLE 20.2202 ACTUAUTHREATENED (a)(2)

ACTUAUATTEMPTED OVEREXPOSURE THEFT X

'NCi eNr rep Rr rRANSPORTAT10N 20.2202 ACTUAUTHREATENED (D)

PROTECTIVE ACTION RELEASE PREVENTED Y NSPORTATION EVENT O THER (Spoofy) 21 21 OEFECTl (c)(1)

UNPLANNED i

NONCOMPLIANCE CONTAMINATION INFORMATION ONLY 1331 SAFEGUAROS EVEN TS (c)(2)

SAFETY EQUIPMENT FAILURE t

K OTHER (Speofy)

CRITICAuTY CON TROL 4-HOUR (c)(3)

MEDICAL TREATMENT (BULLETIN 91 o11 WITH CONTAMINATION j

Loggable Secunty Event CRITICAuTY CON TROL 24-HOUR (c)(4)

FIRE 4XPOUSION (BULLENTIN 91 ol)

OTHER NON-CFR REOU REMENT I

NOTIFICATION Yes No WILL BE ANYTHING UNUSUAL OR NOT Yes (Explain Delow)

UNDERSTOOO?

i j

NRC RESIDENT

^

X No S TATE ($)

X OID ALL SYSTEMS FUNCTION AS NA Yes LOCAL X

REQUIREO7 NA No (Exotain below)

OTHER GOVERNMt:NT AGENCIES X

ACOITIONAL INFORMATlON ON BACK7 Yes MEO PRESS RELEASE X

X No EVEN T DESCRIPTION (Conunued on separate sneet if necessary)

Dunng ADC review of litigation documentation, a CRD document was found containing CRD but not marked as CRD Document was subsequently protected as CRD and retained by Secunty.

This event is reportable as "any infractions, losses, compromises, or possible compromise of classified information or classified documents not falling within 10CFR95.57(a)*. It is being logged per 10CFR95.57(b).

Tha NRC resident inspector has been notified of this event.

PGDP Problem Report No. ATR 99-3887; PGDP Event Report No. PAD-1999 050 Responsible Division: Safety, Safeguards, & Quality (SS&O)

NRC FORM 361C (2 91) 9