__

Georgia Po Post Off:ce

/

Naynesbon 830

'elephone 40, s.in1, Ext 3300 404 724-8114. Ext. 3360 GeorgiaPower D. o. Foster

, l,

, i b,

  • Q d i

Vtce Pres, dent l

Vogt'e Project g

g gg United States Nuclear Regulatory Commission Region II File:

X7BG03-M86 Suite 2900 Log:

GN-1015 101 Marietta Street, Northwest Atlanta, Gavvgia 30323

Reference:

Vogtle Electric Generating Plant-Units 1 and 2; 50-424, 50-425; f5 Accumulator Nitrogen Vent Lines; Letter GN-727 dated 10/25/85 Attention: Mr. J. Nelson Grace Our previous correspondence on this subject notified the USNRC of a reportable concern pursuant to the requirements of 10 CFR 50.55(e) and 10 CFR 21.

Threaded caps were erroneously installed on Unit 1 i

l accumulator nitroger, vent lines and were erroneously shown on the orthographic drawing for the Unit 2 accumulator.

Item 4 in the

" corrective action" section of the evaluation summary attached to this correspondence indicates that the orthographic drawing was revised and the Unit 2 vent line would be shown correctly on isometric drawing 2K4-2402-029-01 when it is issued.

Georgia Power Company has now decided to show the Unit 2 accumulator nitrogen vent line on an existing isometric drawing ( 2J4-2402-008-01).

Drawing 2K4-2402-029-01 will not be issued.

All corrective actions relative to CDR 85-86 are now complete.

This correspondence contains no proprietary information and may be placed in the NRC Public Document Room.

Yours[truly,.

/

A

,[' [',,' [s / - y' L 'l t

/

8609090291 860806 PDH ADDCK 03000424 CW S

PDR D. O. Foster REF/D0F/tdm Attachment xc:

U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C.

20555 J. H. iiiller R. A. Thomas L. T. Gucwa l

J. P. O'Reilly D. R. Altman C. W. Hayes G. F. Head P. R. Bemis G. A. McCarley R. E. Conway J. A. Bailey D. S. Read J. T. Beckham O. Batum Sr. Resident (NRC)

R. H. Pinson G. Bockhold C. S. McCall (OPC)

P. D. Rice C. E. Belflower J. E. Joiner (TSLA)

B. ft. Guthrie J. F. D'Amico D. C. Teper (GANE) -

D. E. Dutton E. D. Groover NORf15 U.S. NRC REGION D 0FFICgCg y