Report Nos.:
50-327/87-16 and 50-328/87-16
Licensee: Tennessee Valley Authority
6N 38A Lookout Place
1101 Market Street
Chattanooga, TN 37402-2801
Docket Nos.: 50-327 and 50-328
License Nos.:
Facility Name: Sequoyah 1 and 2
InspectionConducted:,fiach 4-6, 1987
Inspector:
T
97c! 7
-r
8'7
7
M. F. Runyan
[
Date Signed
' '
Accompanying Personnel.: G.p.Belisle
Approved by:
(
7e
( -:i
7 Th 7
!
G. A. Telisle, Chiof "
Date Signed
Quality Assurance Programs Section
Division of Reactor Safety
SUMMARY
,
Scope:
This special, announced inspection was conducted in the areas of
corrective action and licensee action on previously identified inspection
findings.
Results: No violations or deviations were identified.
8704290285 870413
ADOCK 05000327
G
- - - - _ - . _ . - - .
.
_
. _ _ ..-.._-_.
- - - _
. .-
_-
.-
.
.
.
1
i
l
i
.
REPORT DETAILS
i
t
i
l
1.
Persons Contacted
!
Licensee Employees
V. Bianco. Nuclear Engineer
T. Burdette. Special Assistant to Deputy Manager
i
D.Cowart, Supervisor,QualityAssurance(QA)
i
D. Craven, Site QA Manager
M. Frye, Plant Assessment Section Supervisor
M.Gorman,QualityEngineering(QE)
'
i
- C. Hansen, Licensing Support Section Supervisor
i
B. Hurst, Department of Nuclear Engineering (DNE), Civil Staff
j
- J. Huston, Consultant, Stone and Webster Engineering
R. Jenkins, DNE
i
J. Kearney, Performance Assessment Engineer
J. Killian, Branch Chief, Quality Audit Branch
l
.
- G. Kirk, Compliance Licensing Supervisor
T. Lee, Licensing Engineer
i
A. Morris, Maintenance Planning
'
- R. Parker, Director Division of Nuclear Quality Assurance (DNQA)
}
A. Ritter, Engineering Assessment (EA)
!
J. Robinson,DepartmentofNuclearConstruction(DNC)
M. Stitt, Conditions Adverse to Quality (CAQ) Coordinator
l
D. Widner, DNC
'
i
)
Other licensee employees contacted included office personnel.
NRC Resident Inspectors
-
K. Jenison, Senior Resident Inspector
P. Harmon
j
D. Loveless
!
W. Poertner
1
- Attended exit interview
'
2.
Exit Interview
The inspection scope and findings were sunnarized on March 6,1987, with
those persons indicated in paragraph 1 above. The inspector described the
3
{
areas inspected and discussed the details of the inspection.
No
!
dissenting comments were received from the licensee. The licensee did not
j
identify as proprietary any of the materials provided to or reviewed by
the inspector during this inspection.
4
i
)
.
.
.
.
.
.
. .
.
.
.
2
3.
Licensee Action on Previous Enforcement Matters
This subject was not addressed in the inspection.
1
4.
Unresolved Items
1
Unresolved items were not identified during this inspection.
5.
Corrective Action
,
The licensee introduced a revised corrective action program in procedure
Al-12 (Part I), Corrective Action, Revision 0, dated February 20, 1987.
'
This procedure established a consolidated corrective action reporting
system, replacing most of the previous problem-identifying reports with
Conditions Adverse to Quality Reports (CAQR).
The issuance of this
procedure implemented Nuclear Quality Assurance Manual (NQAM), Part I,
Section 2.16
Revision 2.
AI-12 (Part II), Adverse Conditions and
,
Corrective Actions, Revision 0, was issued simultaneously to provide
measures to process existing conditions adverse to quality (CAQ), which
were previuusly reported on various (now obsolete) reports.
AI-12 (Parts 1 and 2) replaced the previous AI-12, Adverse Conditions and
Corrective Actions, Revision 25, which also provided process controls for
CAQs (which were then more narrowly defined and just one of many reporting
systems).
CAQs were first reported under the new program on February 23, 1987;
therefore, this inspection was primarily focused on the first-stage
i
process of reporting CAQs and an early perception of the potential success
of the program. The inspectors reviewed 70 of the approximately 118 CAQRs
that had been received by the site CAQ Coordinator. These CAQRs had been
initiated by numerous plant groups and documented a wide variety of
'
problems from apparently insignificant issues to broad generic concerns.
Based on the review of CAQRs and discussions with site personnel, it
appeared that the new CAQR program had been initiated in a favorable
l
manner.
Only three CAQRs had been closed at the time of the inspection-CAQR Nos.
SQP870028, SQP870044, and SQP870053.
In each case, the CAQR was closed
without material corrective action.
CAQR No. SQP870028 redundantly
repeated a currently open previous finding, and CAQR Nos. SQP870044 and
SQP870053 were determined to be invalid CAQRs per the AI-12 (Part I)
definition.
In the absence of a sample of closed CAQRs requiring
substantial corrective action, an assessment of the effectiveness of the
corrective action process was not possible during this inspection.
j
In a similar manner, it was too premature to assess the revised CAQR
escalation process described by AI-12 (Part I).
Three CAQRs had been
escalated:
SQP870027 and SQP870065 to determine the responsible group and
SQP870107, sent to Corporate QA, to resolve an assertion that the CAQR
system outdates the Sequoyah Nuclear Performance Plan (SNPP).
-
-
-
-
.
. -
.
-
-
._
._ -
-
.
._ - . _-.-
.
_ . -
-
=_
,
.
,
3
i
Two CAQRs had been written against the CAQR program itself.
CAQR No.
SQP870051 stated that CAQRs have been issued without utilizing the
!
continuation sheet when additional space was needed to describe the CAQ.
j
CAQR No. SQQ870107, as described above, described differences between the
revised CAQR program and statements contained in the SNPP.
This inspection was primarily an information gathering effort to establish
j
a baseline for future inspections during which the overall effectiveness
of the CAQR program will be assessed.
Included in this assessment will be
a review of the disposition of problem reports written under the old
.
i
system (in particular approximately 40 Corrective Action Reports (CAR) and
110 Deficiency Reports (DR)) as delineated by AI-12 (Part II).
Within this area, no violations or deviations were identified.
6.
Q-List
i
A meeting with representatives of various plant groups was conducted to
!
discuss the methods whereby distinctions are made between quality and
[
!
non-quality components for plant maintenance, design, and modification
I
work in the absense of an all-encompassing Quality (Q)-List.
Licensee
personnel explained that currently existing documents are sufficient
'
to positively control the identification of quality items and that the
!
current effort to construct a plant-wide Q-List is an efficiency enhance-
!
ment only.
A schedule for Q-List completion is due three months after
4
startup of Unit 2.
Current sources of information for determining
"
l
equipment classifications include procedure SQA 134, Critical Systems,
r
}
Structures, and Components (CSSC) Listing of Mechancial, Electrical,
.
Instrumentation, and Controls Equipment, the 10 CFR 50.49 List for Units 1
1
l
and 2, plant drawings, and several other specialized lists.
l
f
Within this area, no violations or deviations were identified.
7.LicenseeActiononPreviouslyIdentifiedInspectionFindings(92701)
(0 pen)
Inspector Followup Item 327,328/87-04-01:
Division of Nuclear
,
Engineering (DNE) and Division of Nuclear Construction (DNC) Procedural
i
Adherence to the Nuclear Quality Assurance Manual (NQAM).
i
4
At the time of the inspection, DNE and DNC procedures were not ready for
review to verify compliance with the NQAM requirements.
.
l
!
i
l