Forwards Power Ascension Test Program Startup Rept. Attachment 1 Includes Description of Measured Values of Operating Conditions.Alert Level for Loose Parts Monitoring Sys During Power Operation Is 0.5 ft-lb
ML20207S425
Person / Time
Site: Hope Creek 
Issue date: 03/16/1987
From: Corbin McNeil
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20207S426 List:
References
NLR-N87045, NUDOCS 8703190427
Download: ML20207S425 (2)


Text

,_.

Pubhc Service Electnc and Gas Company CorCin A. McNeill, Jr.

Pubhc Service E:ectoc and Gas Company P.O. Box 236, Hancocks Bndge NJ 08038 609 339-4300 Vece Prew1ent -

N uclear MAR 161987 NLR-N87045 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 FACILITY OPERATING LICENSE NPF-57 STARTUP REPORT TECHNICAL SPECIFICATIONS 6.9.1.2 AND 6.9.1.3 HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric and Gas Company (PSE&G) hereby transmits the Startup Report for llope Creek Generating Station (HCGS) as required by Facility Operating License NPF-57, Technical Specifications 6.9.1.2 and 6.9.1.3.

This report addresses each of the Startup Tests identified in Sections 14.2.12.2 and 14.2.12.3 of the HCGS Final Safety Analysis Report (FSAR).

The Startup Report, contained in Attachment I, includes a description of the measured values of the operating conditions or characteristics obtained during the test program and a comparison of those values with design predictions and specifications.

In accordance with Technical Specification 6.9.1.3, this report is boing provided within 90 days following completion of the Power Ascension Test Program (December 16, 1986).

In accordance with PSE&G commitments in FSAR Sections 7.5.1.3.7.6 and 1.8.1.133, and the guidanco provided in Roqulatory Guido 1.133, Position C.I.b, C.I.0, C.2 and C.3.a(2)(a), the alert level for the Looso Parts Monitoring System (LPMS) during power operation is 0.5 ft-lbs.

Should you have any questions or comments reqardino this transmittal, do not hesitato to contact us.

Sincoroly, Attachmont 0703190427 070316 s' b ADOCK05000g4 fr i

DR

M I 619r7 Document Control Desk 2

C Mr.

D. II. Wagner USNRC Licensing Project Manager Mr. R. W. Borchardt USNRC Senior Resident Inspector