Requests Approval to Utilize ASME III Code Case 1481-2, Elevated Temp Design of Section Iii,Div 1,Class 2 & 3 Components for Thermal Hydrogen Recombiners
ML20207R574
Person / Time
Site: Beaver Valley
Issue date: 03/12/1987
From: Carey J
DUQUESNE LIGHT CO.
To: Tam P
NRC
References
2NRC-7-047, 2NRC-7-47, TAC-64898, NUDOCS 8703170386
Download: ML20207R574 (3)


Text

r

}Vg

'Af M

2NRC-7-047 5 00 Bemr Vall No. 2 Unit Project Organization P.O. Box 328 March 12, 1987 Shippingport, PA 15077 United States Nuclear Regulatory Commission ATTN: Mr. Peter Tam, Project Manager Mail Stop 340 Washington, DC 20555

SUBJECT:

Beaver Valley Power Station Unit No. 2 Docket No. 50-412 ASME 111 Code Case 1481-2

REFERENCE:

1)

Letter from L. S. Rubenstein (NRC) to J. J. Carey (DLC) dated February 2, 1987.

2)

Letter 2NRC-6-122 from J. J. Carey (DLC) to H. R. Denton (NRC) dated December 12, 1986.

Gentlemen:

Duquesne Light Company (DLC) hereby requests approval to utilize ASME III Code Case 1481-2, " Elevated Temperature Design of Section 111, Division 1, Class 2 and 3 Components" for the thermal hydrogen recombiners installed at Beaver Valley Unit 2.

As noted in your letter of February 2,1987 (reference 1), DLC withdraws its request (reference 2) to utilize Code Case N-253 for the thermal hydrogen recombiner application.

Code Case 1481-2 was implemented by the vendor, Rockwell International, to construct the thermal hydrogen recombiners which have design operating tem-peratures exceeding those of the ASME 111 Code.

This code case was approved by the ASME III council July 11, 1977 and expired July 11, 1980.

The BVPS-2 ther-mal hydrogen recombiners are constructed to ASME 111 Class 2, 1977 Edition through Winter 1978 Addendt and this code case was " active" during the period of procurement and construccion.

The stress allowables employed are show in attachment 1 to this letter.

The appropriate FSAR revisions will be included in a future amendment.

Your expeditious review of this request would be greatly appreciated.

DUQUESNE LIGHT COMPANY By

, f.(J/ Larey

/

SenYor Vice Pr esident cc:

Mr. J. Beall, NRC Sr. Resident Inspector Ms. A. Asars, NRC Resident inspector INP0 Records Center

/

NRC Document Control Desk BooI B703170386 870312 PDR ADOCK 05000412 A

PDR

United States Nuclear Regulatory Commission

  • e Mr. Peter Tam, Project Manager ASME 111 Code Case 1481-2 Page 2

+

COMMONWEALTH OF PENNSYLVANIA )

)

SS:

COUNTY OF BEAVER

)

On this //O day of

/)'z/I[/

,/f

, before me, a Notary Public in and for said Commonwealth; and County, personally appeared J. J. Carey, who being duly sworn, deposed and said that (1) he is Senior Vice President of Duquesne Light, (2) he is duly authorized to execute and file the foregoing Submittal on behalf of said Company, and (3) the statements set forth in the Submittal are true and correct to the best of his knowledge.

1 l lG.] h '

W Notary Public

$ltEMA G. FA!'CRI. Monaf rusuc suimanecat sono, erAvta coum av commissar ExviaEs ocT.23. tset teeneer. Pawayfenis Assoasties of lietsies l

I

f5:_

J7

. 3U ATTACHMENT 1 Stress Allowables:

Materi als*

C/C 1481-2 (ASME-Vill. Table UHA-23)

SA312,T304/T304H 2,300 PSI @ 1400*F

.SA313,T304/T304H 2,300 PSI @ 1400*F SA182,F304/F304H 2,300 PSI @ 1400*F SA240,T304 2,300 PSI @ 1400*F SA479,T304 2,300 PSI @ 1400*F Notes:

a.

The total service time at temperat'ure above 300*F does not exceed 10,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />.

b.

The carbon content for the stainless steel materials used is 0.04 percent or higher.

  • This information supersedes the data presented in Reference 2.