Discusses Steam Generator Tube Plugging Following Inservice Insp,Per Tech Spec 4.4.5.5.a.Encl Summarizes Status of Unit 1 Tubes Plugged as of 870227.All Tubes Previously Identified as Plugged,Deplugged
ML20207R307
Person / Time
Site: Sequoyah 
Issue date: 03/13/1987
From: Domer J
TENNESSEE VALLEY AUTHORITY
To: Ebneter S
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
References
TAC-R00139, TAC-R139, NUDOCS 8703170089
Download: ML20207R307 (3)


Text

.

.. e TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 37401 SN 1578 Lookout Place MAR 13 27 U.S.-Nucleer Regulatory Cosunission At.tn: Document Control Desk Office of Nuclear Reactor Regulation Washington, D.C. 20555 Attention:

Mr. Stewart Ebneter In the Nat[ter of

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 SEQUOYAH NUCLEAR PLANT (SQN) UNIT 1 - ETEAN GENERATOR (S/C) TUBE PLUGGING FOLLOWING INSERVICE INSPECTION In accordance with the requirements of the SQN technical specification 4.4.5.5.a. enclosed is the status of tubes plugged in each unit 1 steam generator resulting from inservice inspection of S/G tubes performed February 1987. Please note that all tubes previously identified as being plugged in the Sequoyah unit 1 S/Gs have been deplugged, and the list provided in this report (enclosure) identifies the only tubes plugged in the unit 1 S/G at this time. All row 1 tubes previously identified as having nonquantifiable defects, having indications of U-bend defects, or having been preventively plugged have been returned to service by U-bends being heat treated and postheat treatment eddy current inspected. The 12 tubes identified in the enclosure represent the only tubes identified to have remaining U-bend defects and were removed from service by plugging.

If you have any questions concerning this matter, please call M. R. Harding at 615/870-6422.

Very truly yours, TENNESSEE VALLEY AUTHORITY

)J.A.Domer,AssistantDirector

. a.

Nuclear Safety and Licensing Sworn tg d subscr d bef a me thi 23 ay,of _ ///

98[

llotary Public My Conunission Expires _

Enclosure cc: See page 2 h

n703170069 870303 PDR ADOCK 05000327 PDR An Equal Opportunity Employer 0

. U.S. Nuclear Regulatory Commission g

cc (Enclosure):

Mr. J. J. Holonich Sequoyah Project Manager U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20814 Mr. G. G. Zech, Director TVA Projects U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Sequoyah Resident Inspector Sequoyah Nuclear Plant 2600 Igou Ferry Road Soddy Daisy, Tennessee 37379 i

,,m.,

,, ~.,,, _ _ -.

b

^

ENCLOSURE SEQUOYAH NUCLEAR PLANT UNIT 1 INSERVICE INSPECTION OF STEAM GENERATOR TUBES REPORT OF TUBES PLUGGED IN ACCORDANCE WITH TECHNICAL SPECIFICATION 4.4.5.5.a The following provides a sununary status of unit 1 S/G tubes which are plugged i

effective February 27, 1987. All tubes previously identified to NRC as being plugged have been deplugged, and the following identifies the only tubes plugged in each S/G.

SG #1 Row Col Indication (%)

Location Reason For Plummina 4

1 17 Nonquantifiable U-bend Eddy Current Indication 1

20 Nonquantifiable U-bend Eddy Current Indication 1

69 Nonquantifiable U-bend Eddy Current Indication 4

1 61 Nonquantifiable U-bend Eddy Current Indication 1

81 Nonquantifiable U-bend Eddy Current Indication SG #2 1

Row Col Indication (%)

Location Reason For PluRRinz i

1 43 Nonquantifiable U-bend Eddy Current Indication 1

45 Nonquantifiable U-bend Eddy Current Indication 1

63 Nonquantifiable U-bend Eddy Current Indication SG #3 Row Col Indication (%)

Location Reason For Plu1Rint 1

45 Nonquantifiable U-bend.

Eddy Current Indication 4

1 84 Nonquantifiable U-bend Eddy Current Indication 1

86 Nonquantifiable U-bend Lcaker i

SG #4 Row Col Indication (%)

Location Reason For PluRKing 1

88 Nonquantifiable U-bend Eddy Current Indication i