ML20207N289

From kanterella
Jump to navigation Jump to search
Forwards Revised Response to 861028 Notice of Violation from Insp Rept 50-312/86-14.Response to Violation C.3 Should Read Eight Radiation Protection Personnel Will Be Trained in Std multi-media by 861231
ML20207N289
Person / Time
Site: Rancho Seco
Issue date: 12/31/1986
From: Julie Ward
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
JEW-86-982, NUDOCS 8701140101
Download: ML20207N289 (3)


Text

=

g# SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT O P. O. Box 15830, Sacramento CA 95852-1830,(916) 452-3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA JEW 86-982 d-f December 31, 1986 g

D j

"f-t.

fo (P

J.

B. Martin, Regional Administrator Region V Office of Inspection and Enforcement U S Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596 Docket No. 50-312 Rancho Seco Nuclear Generating Station Unit #1 License No. DPR-54 NRC INSPECTION REPORT 86-14

Dear Mr. Martin:

By letter dated December 1, 1986, the Sacramento Municipal Utility District responded to your Notice of Violation transmitted on October 28, 1986.

Due to a miscount, we incorrectly stated that nine Radiation Protection personnel will be trained in Standard Multi-media by December 31, 1986, in our response to Violation C.3.

The correct number l

of Radiation Protection personnel to be trained in Standard Multi-media by December 31, 1986 is eight (8).

l In accordance with 10 CFR 2.201, the Sacramento Municipal Utility District submits our revised response to Violation C.3.

Sincere PA & d #

John -E. Ward Deputy General Manager, Nuclear

Attachment:

cc:

Region V (2)

INPO

\\\\

8701140101 861231

_-c/

PDR ADOCK 0500 2

O

" ~ '

HANCHO SECO NUCLEAR GENERATING STATION O 14440 Twin Cities Road, Herald, CA 95638-9799;(209) 333-2935

]

NRC Violation C.3 Section IV.F of appendix E requires initial training and retraining of emergency personnel.

Section 6.2.7 of the emergency plan required that health physics personnel and the emergency team will be provided Advanced First Aid and Multi-Media every three years.

Contrary.to the above, at the time of the inspection, retraining in the Standard Multi-Media had been discontinued more than three years ago and retraining in Advanced First i

Aid was discontinued more than five years ago.

This is a Severity Level V Violation (Supplement VIII).

District Revised Response to Violation C.3 1)

Admission or denial of alleged violation.

The District admits that this violation occurred as stated.

2)

Reasons for violation:

The violation was due to the Emergency Plan not being revised to reflect that First Aid Training for emergency team membec, could be provided at an instructional level equivalent to Advanced First Aid.

An additional contributor was the utilization of emergency medical technicians as First Aid instructors who were not able to issue Red Cross Certification Cards.

l 3)

Corrective actions taken and results achieved.

Review of 1985 and 1986 First Aid training documentation indicated that Emergency First Aid training was provided to licensed operators as a requalification training i

l program topic.

This review also indicated that the j

training was provided to a level equivalent to Advanced First Aid including Multi-Media.

Two instructors, who are qualified to issue Red Cross Certification, have been hired to provide Advanced First Aid training.

l t

l 15

b 4)

Corrective Actions which will be taken; Section 6.2.7.d. of the Emergency Plan will be revised to reflect the acceptance of both Advanced First Aid or the equivalent.

Emergency Team members will be enrolled in appropriate training and retraining programs.

At least one member of the Emergency Team will have Advanced First Aid Training or the equivalent.

Eight Radiation Protection personnel will be trained on Standard Multimedia by December 31, 1986.

5)

Date when full compliance will be achieved.

The District considers that full compliance will be achieved with the revision of the Emergency Plan prior to restart May 1, 1987.

1 1

16

--