m
-
-
.
1
.
>
'*
JAN 081987
Docket No. :
030-12378
License No.: 50-17150-01
Chemical & Geological Laboratories
.of Alaska, Inc.
5633 B Street
Anchorage, Alaska 99518
Gentlemen:
"
This refers to a telephone inquiry conducted by Frances.Roselinsky,_of this
office, on January 6, 1987.
The inquiry was an examination of activities conducted under your license as
they relate to radiation safety and to compliance of the Commission's rules
and regulations and with the conditions of your license. The inquiry
consisted of discussions with Stephen C. Ede, Vice President.
As a result of this examination of activities, regulatory concerns were noted
and are specified below. These may be evaluated at an onsite inspection at
your facility in the near future.
As_you described on the telephone, the following apparent regulatory concerns
were identified:
-
1.
Failure to leak test sealed sources at the required intervals.
2.
Failure to perform physical inventories at the required intervals.
It is our understanding that these items will be corrected. A license
amendment will bel required to change leak test intervals from 6 months to 36
months. Physical ~ inventories will be conducted every 6 months, and records-
of these invento' ries will be maintained.
If you have any questions regarding this inquiry, you may contact R. D.
Thomss at (415).943-3763.
Sincerely,
,
.
,
,
c
-James
. Montgome y, Chief
Nuclear Materials Safety and
Safeguards Branch
i
bec w/ copy of telephone interview:
G. Cook
B. Faulkenberry
-J. Martin
Str.te of Alaska.
RSB/ Document Control Desk (RIDS)
REGION V/ norma
g
FRoselinsky
RThomas
ontgomery
EV
W
1/1/87
1/7/87
1/g,,/
/87
'
01 870108
3g
!E
30
,,01
30-17
ye7
l
g
EVALUTION OF POSSESSIONS AND USE OF BYPRODUCT MATERIAL
,
LICENSEE: Chemical & Geological Laboratories
LICENSE NUMBER: 50-17150-01
of Alaska, Inc.
DOCKET NUMBER: 030-12378
5633 B Street
PHONE NUMBER:
907-562-2343
Anchorage, Alaska 99518
NAME AND TITLE OF PERSON INTERVIEWED:
St; phen C. Ede
Vica President
DOES YOUR LICENSE PROPERLY REFLECT YOUR PROGRAM?
y;3
NAME AND TITLE OF PERSON RESPONSIBLE FOR RADIATION SAFETY PROGRAM:
St: phen C. Ede
Vics President
DESCRIBE HOW THIS MATERIAL IS USED:
cample analysis using a gas chromatograph
DESCRIBE HOW YOU SAFEGUARD THE BYPRODUCT MATERIAL FROM USE BY UNAUTHORIZED PERSONNEL:
it is in a mounted device near authorized users
DESCRIBE IiOW YOU SAFEGUARD THE MATERIAL FROM LOSS OR THEFT:
it is mounted near authorized users in a secured building
DESCRIBE CONTROLS Wi!ICil PREVENT INDIVIDUALS WHO WORK IN THE AREA AROUND THE MATERIAL
FROM BECOMING EXPOSED TO RADIATION:
th; cells are always sealed
e
DO YOU HAVE A PERSONNEL MONITORING PROGRAM FOR YOUR EMPLOYEES SUCH AS FILM BADGES,
DOSIMETERS, ETC.?
N/A
IF YES, WERE THERE ANY EXPOSURES TO INDIVIDUALS IN EXCESS OF 1.25 REMS FOR ANY
CALENDAR QUARTER 7
N/A
IF YES, DOSE
, QUARTER
, YEAR
,
N/A
DO YOU PERFORM SURVEYS TO DETECT EXTERNAL RADIATION IN THE AREA AROUND THE BYPRODUCT
MATERIAL?
N/A
IF YES, HOW 0FTEN ARE THE SURVEYS PERFORMED?
N/A
l
l
I
..
-_
-
.
'hesi,c Q & Gerirgichl Laboratirica
-2-
C
WHAT INSTRtMENT IS USED TO PERFORM.THE SURVEYS?
.
N/A.
WHEN WAS THIS INSTRUMENT LAST CALIBRATED?
,
N/A
!
.WHEN WAS THE LAST PHYSICAL INVENTORY OF ALL BYPRODUCT MATERIAL IN YOUR POSSESSION
PERFORMED?
N:vember 1986, done yearly
DO YOU PERFORM LEAK TESTS ON THE SEALED SOURCE?.
'
. y23 ;
IF YES, HOW 0FTEN~ARE THESE LEAK' TESTS PERFORMED?
cvary 2 years, last done in 1985
.
- WHO EVALUATES THE LEAK TEST RESULTS?
Vcrian Instruments
IF NO,' DESCRIBE THE PROVISIO S YOU HAVE MADE TO HAVE THE LEAK TESTS DONE:
N/A
DESCRIBE YOUR PROVISIONS FOR REPAIR AND-MAINTENANCE OF YOUR DEVICE OR SOURCE HOLDER:
~
'
rsturned to Varian Instruments'
DESCRIBE ANY UNUSUAL EVENTS INVOLVING THE BYPRODUCT MATERIAL OR DEVICE IN WHICH IT IS
USED:
,
-
N/A
,
i
hVk}
id
,
Frances Roselinsky
/
,
Name of person filling in
-
i
questionnaire
Licensing Assistant
,
Title
,
January 6, 1987
Date
,
1
,
l-