UNITED STATES

[ *'

o,i NUCLEAR REGULATORY COMMISSION 7,

a WASHINGTON, D. C. 20555 o\\.....

NORTHEAST NUCLEAR ENERGY COMPANY DOCKET NO. 50-245 MILLSTONE NU, CLEAR,,P,0WER, STA,TIOL,0 NIT, N0.,1 AMENOMENT TO FACILITY OPERATING LICENSE Amencment No. 24 License No. OPR-21 1.

The Nuclear Fegulatory Constission (the Comission) has found that:

A.

The application for amendnent by Northeast Nuclear Energy Company (the licensee), dated June 3, 1988, complies with th?. standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Conmissien; C.

There is reasonable assurance (i) that the activities authorized by this anendaent can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commis',1on's regulations; D.

The issuance of this amendrent will not be inimical to the conron defense and security or to the health and safety of the public; and E.

The issuance of this amendrent is in accordance with 10 CFR Part 51

)

of the Comission's regulations and all applicable requirements have been satisfied.

]

1 8010170406 081011 4

PDR ADOCK 05000245 i

P PNV t

' 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendnent, and paragraph 2.C.(2) of Facility Operating License No. DPR-21 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendix A, as reviseu through Amendment No. 24, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of issuance, to be implemente.

'hin 30 days of issuance.

FORTHENUCLEARREGULpTORYCOMMISSION Au ],4%

ohrI7% Stolz, Director (Pr@isionofReactorProjectsI/II ect Directorate I-4 Div Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: October 11, 1988 4

i 1

i

4

)

t I

ATTACHMENT TO LICENSE AMENDF'NT NO. 24 i

FACILITY OPERATING LICE;tSE NO. DPR-21 DOCKET NO. 50-245 l

i Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages.

The revised pages are identified by amendment number and contain vertical lines indicating the areas of change.

Remove Insert 3/4 11-3 3/4 11-3 l

t 1

a 3/4 11-4 3/4 11-4 i

i l

4 t

i i

l I

I 4

1 j

+

l 4

i i

1 j

N g

3 l

W a

E e

\\

a g

4 I

g o

=-

m

[ is I

I 1

/

IIu.I

/

(I5a3j e

e d

I

- 3.

g.,i y

..E i1 glI-8 e

a m

j,!

._z-5 m

m e

e P

i wI a

&o g

e, l

b.: '

I m

g s

l' I

Is

-I i

a:

s uu s'.I o.

  • g-se 5

S

~

b

.!?

i

=

a

.j O 6/"M C

lava mo Avv3 mis tv3w vv3m:1 vvwvis 1sys Av w wiryw E

12 i

4 1

a Q.2

- I.

10~3 10.

ID i

10.6 10.

10.

l o.10.2 0*

30 i

I d

.8 9,7 e.55 nulaletIer Applied uhem as speratlag At <30% of assed Core Wien 9.05 y'

i N

t r

9 5

8.6 u

\\

h

\\

\\

.3 6.$'

6-1

'6.

O 3coe 10.090 15,000 20,0am 25,000 30,n00 J

3',000 40,000 43,030 50,000 PLANAR AVERACE EXPOSURE, MlJd/t Figure 3.ll.I.b.-Maximum Average Planar Linear IIcat Ceneration Rate (MAPLIICR) Versus Planar Average i

Exposure for Most Limiting Lattice Type *, Fuel Type 20338A (CE-8x8EB)

  • Lattice specific MAPLIICR values are given in NEDE-240835-1-P, LOCA Report for MNPS-1, Su[pl.1 (NOTE; Lattice Speci,{1c values must be multiplied by G.98 for rumpinder.jf Cycle 12 operation) i Millstone Unit i.

3/4 11-4 Amendment No. 24

-