I

~

o e

7.'

GPU Nuclear Corporation g

gf Post Office Box 480 Route 441 South Middletown, Pennsylvania 17057-0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number:

Novmber 26, 1986 5211-86-2202 Dr. Thomas E. Murley Region I, Regional Administrator US Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406

Dear Dr. Murley:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Emergency Action Levels

/is required by 10CFR50, Appendix E, Section IVB, we are forwarding a revision of Emergency Action Level (EAL) 8.1.D for your approval. EAL 8.1.D, High Winds has been revised to include more specific measurable parameters and to more closely conform to the guidance contained in NUREG 0654/ FEMA-Rep-1. contains the existing 8.1.D and Enclosure 2 contains the revision of 8.1.D.

This revision has been reviewed by the Pennsylvania Bureau of Radiation Protection and they agree with the proposed changes, iWe request your review and approval within 30 days so that this EAL revision can become effective.

Sincerely, i

kill

\\

Vice President & Director, TMI-l HDH/DVH/spb cc:

F. Young 0718A G701070331 861229 PDR ADOCK 05000289 F

PDR GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation

FOms. loco-ADes.121818 2 8tlf.29 e

=4 4ob O

> e="

E t's fantr lea:

TMt.1 Derar.rMCY AC110M LIVELS

g UNUSUAL Stif AREA C(n(RAL 4O M

E yLgI AL[RI

[M BCK IIr T Det SCf er y hg S.S flATURAL and s4AN-MADE PntistpWNA Og vi 7

O --e 3.3 Natural phencimena being Severe natural phenaniena Severe natural phenomena N/A

'I M (Natural Phenomena) empertenced Og projected being empertenced as being esper tenced Og Q@

beyond usual levels as indstated by one of the projected as indicated by endscated by one of the following condit tons, one of the following E F's f ollowing condit tons.

durtng operation at power:

conditions 8f50 the plant 5%

durlog operatton at power:

ts MI in cold shutdown:

Is vi o 7

>m 3

eIa VALip alarm PRF-l.2 WAllp alarm PRF-1 3 YALig

II/A O

V oz a

liarthquake)

"Ihreshold Setsatt Con-

,

  • Operating Basts farth-quake Condetton* ()S.12g 44 7

setton (ae.6to but so.o6s quane* fie 06, but ee.12e esor tiontal Acceleration

$m j

a Mactroetal Accentratton Morisontal accelevat ion eng/Ds as.ees vertical rei

~ '

dt d tg it.ete but so.e's AMD/0g 30.o4, but to see Acceles e t t oa p r*

w m

3

  • ' set cal Acceleration ver t ical aueteistion f,.

)#

y' s

n -v1 xn N

O

  • i c -
o uz s.l.a.

ft 1"SJLCl[D rever stor ft. but <3a7 ft.

^311f3 ft. K IWAL river stase n/A

-.4

. "e * *e+ r i v e r =a t er MO tusoh alver tevell AClyat river stage et the at t.he rever mater intakt Z

z ins... stra ture 450 rear river mater intate steuctuse.

M

]

flood levell st ruc t ur e.

m u

6.1 C.

s272 ft. EgGJ[CILD rtver e271 ft. PPQJLCILC rf.er

<279 ft. 8CIM8L river stage N/A ret r=

z (tow Sever tevel) stage at the river mater stase at are ther mater at the river water intake intat e st ruc tur e E so year intate struc tu'e structuie.

lam level) f 8 1.0 noen winds sustone to 275 Any tornado strthtne the Su-dain.-J tornado conditions N/A tutoh Wtnes) siph as indicated on Wind factlety Speed Recorder imDS-50I) 3 7

g c

prg 3,

3 =

OR aluol og (IWol Og Itwu) a far 1o efICIO5ure 2) g g

y n

,,,,,,,,,,,,,,,,y5,,

f

(,'

P c3 Ser vice has suued a of 3 5 mph but 4585 mph 195 mph as indicated on O

7 cC.g,

o Toe nata or Hur r tc ane Force as Indicated on Wind Wind Speed Secorde"

)

t y

g Q

Winds 'WAICH*

Speed Recorder (h05 5 ell quDS-Sell U~

P, d

DI 3

~~

3 c>

~

pe

^

j...

r-u n

f

/

ENCLO[URE2;

- ~;

,~

, l ';"

~

UNUSUAL EVENT

' ALERT SITE AREA GENERAL AREA EMERGENCY EMERGENCY 8.1.D The average wind The average wind The average wind-N/A g

(High Winds) speed is greater speed is greater than speed is greater than 60 mph for 74 mph for a period than 80 mph for a more than 1 of more than 45 period of more than minute as in-seconds as indicated 45 seconds.

dicated on Wind on Wind Speed Recorder Speed Recorder (NDS-501).

(NDS-501).

QR_ (TWO)

OR (TWO)

OR (TWO)

Three Mile The National Weather The National Weather Island is in-Service (NWS) is fore-Service (NWS) is fore-cluded in a casting sustained winds casting sustained winds National Weather in excess of 74 mph for in excess of 80 mph for Service (NWS) the Harrisburg area the Harrisburg area within tornado or high-within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, wind " WARNING" area.

OR (THREE)

QR_ (THREE)

The NWS expects a THe NWS expects a tornado a tornado to track of F5 intensity to track directly over the directly over the facility.

facility.

l OR (POUR)

OR (FOUR) y Any tornado striking Any tornado of F5 intensity the facility.

striking the facility.

j

-