Advises That Util 861114 & Westinghouse 861029 Requests That Proprietary CAW-86-100, Alternative Pipe Break Criteria - Accumulator Line,South Texas Project,Units 1 & 2, Be Withheld (Ref 10CFR2.790),approved
ML20207F468
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 12/22/1986
From: Noonan V
Office of Nuclear Reactor Regulation
To: Wiesemann R
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
References
NUDOCS 8701060029
Download: ML20207F468 (5)


Text

- - _ . . .n . , .

.. ,. ~ . >

s. '

/ 'o "g UNITED STATES

!" o NUCLEAR REGULATORY COMMISSION

$  ;$ WASHINGTON. D. C. 20555 4, * * * * * ,o 2 2 DEC M Docket Nos.: 50-498 and 50-499 Mr. R. A. Wiesemann, Manager Regulatory and I.egislature Affairs R. Westinghouse Electric Corporation P.O. Box 355 Pittsburgh, Pennsylvania 15230

Dear Mr. Wiesemann:

u

SUBJECT:

WITHH01. DING FROM PURI.IC DISCl.0SURE "Al.TERNATIVE PIPE AREAK CRITERIA - ACCUMUI.ATOR I.INF" - SOUTP TEXAS PROJECT, l' NITS 1 & 2 - CAW-86-100 13y Houston I.ighting and Power Company letter, dated November 14, 1986, and Westinghouse letters, dated October 29, 1986 and affidavit, dated November 21, 1984, you submitted a Meetino Presentation, dated October 15, 1986 on the Alternative Pipe Break Criteria - Accumulator 1.ine and reauested that it be withbeid from public disclosure pursuant to 10 CFR 2.790. A non-proprietary version of this presentation was also subnitted and has been placed in the NRC's Public Document Rooms.

You stated that the submitted information should be considered exempt from mandatory public disclosure for the following reasons:

1. The information sought to be withheld from public disclosure is owned and has been held in confidence by Westinohouse.

The information is not available in public sources and was submitted to the NRC in confidence and received in confidence.

2. The information is marketable in many ways and the extent to which the information is available to competitors diminishes the Westinghouse ability to sell products and services involving the use of this information. Release of this information to the public would diminish the competitive status of Westinchouse.

We have determined that the infortration submitted on " Alternative Pipe Break Criteria - Accumulator I.ine" on the South Texas Proiect dockets, marked as proprietarv, should be withheld from public disclosure pursuant to 10 CFR 2.740(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as arrended.

We therefore approve your request for withholdino pursuant to 10 CFR 2.790 and are withholding the above stated docueent from public inspection as proprietary.

Nhhf9g PDR

--; o, .

r: _ , .f .. e .

n .

3 i,o Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents. If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, insure that the consultants have sianed the appropriate agreements for handling proprietary information.

If the basis for withholding this information from public inspection should chance in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You should also understand that the NRC may have cause to review this determination in the future, such as if the scope of a Freedom of Information Act reouest includes your information. In all review situations, if the NRC needs additional information from you or nakes a determination adverse to the above, you will be notified in advance of any public disclosure.

Sincerely,

' /

Jt , a, ~6r P R Project Direc orate No. 5 Division of PWR I.icensina-A ,

. cc: Houston I.iahtino A Power Company See next page L

4 i

, z. ,. -

c h

Mr. J. F. Goldberg Houston 1.ighting and Power Company South Texas Profect CC* i Brian Berwick, Esq. Resident Inspector / South Texas Assistant Attorney General Project Environmental Protection Division c/o U.S. Nuclear Regulatory Commission P. O. Box 12548 P. O. Box 910 Capitol Station Bay City, Texas 77414 Austin, Texas 78711 Mr. Jonathan Davis Mr. J. T. Westerceir Assistant City Attorney Manager, South Texas Pro.fect City of Austin Houston I.ighting and Power Company P. O. Box 1088 P. O. Box 1700 Austin, Texas 78767 Pouston, Texas 77001 Ms. Pat Coy Mr. H. L. Peterson Citizens Concerned About Nuclear Mr. G. Pokorny Power City of Austin 5106 Casa Oro P. O. Box 1088 San Antonio, Texas 78233 Austin, Texas 78767 Mr. Mark R. Wisenberg Mr. J. B. Poston Manager, Nuclear I.icensing Mr. A. Von Rosenberg Houston 1.ighting and Power Company City Public Service Boad P. O. Box 1700 P. O. Box 1771 Pouston, Texas 77001 San Antonio, Texas 78296 Mr. Charles Halligan Jack R. Newman, Eso. Mr. Burton I. I.ex Newman & Poltzinger, P.C. Bechtel Corporation 1615 1. Street, NW P. O. Box 2166 Washington, D.C. 20036 Houston, Texas 77001 Melbert Schwartz, Jr., Esq. Mr. E. R. Brooks Baker & Rotts Mr. R. l.. Range One Shell Plaza Central Power and I.ight Company Houston, Texas 77002 P. O. Box 2122 Corpus Christi, Texas 78403 Mrs. Peggy Buchorn Executive Director Citizens for Equitable Utilities, Inc.

Route 1, Box 1684 Brazoria, Texas 77422 i

t c, ,  :,, z c;. - .

-u . . -

, , ,, __.  ; , .3

, 1 w, -q. .

Houston lighting & Power Company South Texas Pro.iect i

cc:

Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Office of Executive Director for Operations g 611 Ryan Plaza Drive, Suite 1000 t Arlington, Texas 76011 .

Mr. lanny_Sinkin, Counsel for Intervenor i Citizens Concerned about Nuclear Power, Inc.

Christic Institute 1324 North Capitol Street Washington, D.C. 20002 l.icensing Representative Houston lighting and Power Compary Suite 1309 7910 Woodmont Avenue Bethesda, Maryland 20814 l

l L

L

2 2 DEC 1986 Withholding from public inspection shall not affect the richt, if any, of persons properly and directly concerned to inspect the documents. If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, insure that the consultants have signed the appropriate agreements for handling proprietary information.

If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC. You should also understand that the NRC may have cause to review this determination in the future, such as if the scope of a Freedom of Information Act request includes your information. In all review situations, if the NRC needs additional information from you or makes a determination adverse to the above, you will be notified in advance of any public disclosure.

Sincerely, Vincent S. Noonan, Director PWR Pro. ject Directorate No. 5 Division of PWR l.icensing-A cc: Pouston 1.ighting & Power Company See next page Distribution

Docket File 4 NRC PDR I.ocal PDR PD#5 R/F V. Noonan P. Kadambi M. Rushbrook E. Shomaker, OEl.D E. Jordar.

B. Grimes J. Partlow Py5 MRu rook:ss k8hd P7adambi E homak r DIR:P #f.

VNoong/) ,

12/ e,/86 12/h/86 1P/p86 12/g86 pus-4pr i ser - n We