ML20207D409

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-498/99-03 & 50-499/99-03 on 990222- 25.No Violations Noted.Inspectors Determined That Radiological Environ & Meteorological Monitoring Programs Effectively Implemented
ML20207D409
Person / Time
Site: South Texas  
Issue date: 03/04/1999
From: Good G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Cottle W
HOUSTON LIGHTING & POWER CO.
Shared Package
ML20207D414 List:
References
50-498-99-03, 50-498-99-3, 50-499-99-03, 50-499-99-3, NUDOCS 9903090328
Download: ML20207D409 (5)


See also: IR 05000498/1999003

Text

-

.

--

- - .

_

.

  1. "'8%g

UNITED STATES

3

&

NUCLEAR REGULATORY COMMISSION

a

.

3

-

T.

j

REGloN iv

[

611 RYAN PLAZA DRIVE, sulTE 400

ARLINGTON, TEXAS 76011-8064

,,,,,

March 4, 1999

William T. Cottle, President and

Chief Executive Officer

STP Nuclear Operating Company

P.O. Box 289

'

Wadsworth, Texas 77483

SUBJECT: NRC INSPECTION REPORT NO. 50-498/99-03; 50-499/99-03

Dear Mr. Cottle:

This refers to the inspection conducted on February 22-25,1999 at the South Texas Project

clectric Generating Station, Units 1 and 2 facilities. The enclosed report p.esents the results

31 this inspection.

The inspectors determined that the radiological environmental and meteorological monitoring

programs were effectively implemented.

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and its

enclosure will be placed in the NRC Public Document Room (PDR).

Should you have any questions concerning this inspection, we will be pleased to discuss them

i'

with you.

Sincerely,

e

. g

.

Gail M. Good, Chief

Plant Support Branch

Division of Reactor Safety

Docket Nos.: 50-498

50-499

License Nos.: NPF-76

NPF-80

Enclosure:

NRC Inspection Report No.

50-498/99 03;50-499/99-03

.

9903090320 990304

,

PDR

ADOCK 05000498

1

G

PDR

i

- - - -

_ _ . _ , _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

'

.

,

,

,

STP Nuclear Operating Company

-2-

cc w/ enclosure:

. T. H. Cloninger, Vice President

Engineering & Technical Services

STP Nuclear Operating Company

P.O. Box 289

Wadsworth, Texas 77483

,,

A. Ramirez/C. M. Canady

City of Austin

Electric Utility Department

721 Barton Springs Road

Austin, Texas 78704

'

Mr. M. T. Hardt/Mr. W. C. Gunst

City Public Service Board

P.O. Box 1771

San Antonio, Texas 78296

D. G. Tees /R. L. Balcom

Houston Lighting & Power Company

P.O. Box 1700

Houston, Texas 77251

Jon C. Wood

Matthews & Branscomb

One Alamo Center

106 S. St. Mary's Street, Suite 700

San Antonio, Texas 78205-3692

Jack R. Newman, Esq.

Morgan, Lewis & Bockius

1800 M. Street, N.W.

. Washington, D.C. 20036-5869

4

Mr. G. E. Vaughn/Mr. C. A. Johnson

Central Power & Light Company

,[

P.O. Box 289

Mail Code: N5012

Wadsworth, Texas 77483

INPO

Records Center

.

700 Galleria Parkway

Atlanta, Georgia 30339-5957

,

i

l

I

\\

'

'

.i

-

_

_

-

_

,

_

..

-

. .~

. . . . . . . .

.

. . - . . . . . . - - - .

..

. - , .

. ..

- -

.-

.

s

%

.

!

'

i,

>.

3

I

. STP Nuclear Operating Company

-3-

Bureau of Radiation Control ~

State of Texas

.

. 1100 West 49th Street '

-

Austin, Texas 78756

,

,

i

>

t

Mr. Jim Calloway

j

Texas Public Utility Commission

1Niiliam B. Travis Building

i

1701 North Congress Avenue

P.O. Box 13326

.

!

- Austin, Texas 78701 3326

e

i

John Howard, Director

!

Environmental and Natural Resources Policy

l

Office of the Governor

!

P.O. Box 12428

l

Austin, Texas 78711

-

Judge, Matagorda County

.

Matagorda County Courthouse

1700 Seventh Street

.

Bay City, Texas 77414

.

1

i

i

,

4

.

J-

i

i

t

i

$'

.

.

.

.

STP Nuclear Operating Company

-4-

9

E-Mail report to T. Frye (TJF)

1

E-Mail report to D. Lange (DJL)

'

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Dc !i (LOCDESK)

)

bec to DCD (IE06)

bcc distrib. by RIV:

Regional Administrator

STP Resident inspector

i

DRP Director

DRS-PSB

-

DRS Director

MIS System

Branch Chief (DRP/A)

RIV File

Project Engineer (DRP/A)

R. Bachmann, OGC (MS: 15-B-18)

Branch Chief (DRP/TSS)

,

'

.

DOCUMENT NAME: R:\\_STPWT903RP.MPS

To receive copy of dgument, Indicate in box: 'C' = Copy without enclosures "E" = Copy with enclosures "N" = No copy

RIV:PSB AA -E PSB d

E

PSB(pgl

C:DRS\\PSB

C:DRP\\A f T,

-

GGood (Ar{ RCTapia (D([M

MShannon:5h

JDo-ion

BNichokL/1 ,,

03fil99

03% A

03///99 _/F 03/ 499 ~

03 4'99 7 l}

~

'

OFFICIAL RECORD COPY

V

I

i

. .

. .

.

. _ . _

. _ _

_.

_

. _ . .

.

_..

,

.

o-

'

.

STP Nuclear Operating Company

-4-

!

E Mail report to T. Frye (TJF)

E Mail report to D. Lange (DJL)

E Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

'

,

'

bec to DCD (IE06)

bec distrib. by RIV:

l

Regional Administrator

STP Resident inspector

DRP Director

DRS-PSB

}

DRS Director

MIS System

RIV File

j

Branch Chief (DRP/A)

.

R. Bachmann, OGC (MS: 15-B-18)

-

Project Engineer (DRP/A)

Branch Chief (DRP/TSS)

i

,

'

!

i

'

'

i

i

!

,

,

4

.

!

i

!

l

4

.,

5

,

DOCUMENT NAME: R:\\_STP\\ST903RP.MPS

To receive copy of degument, Indicate in box: "C" = Copy without enclosures *E" = Copy with enclosures "N" = No copy

RIV:PSB hh

E

PSB d

E- PSB(pegl

C:DRS\\PS B

C:DRP\\A - ;

-

f

,

MShannon:hh

JDods'on

BNichoht)7 ' sGGood Jh{ L.ATapia MX [M

037,J99

03/#99

03/f/99 /V 03/499

034/99 1 7 i)

~

OFFICIAL REC 6RD COPY

\\/

'

,

.

,

090095

i

..

.

~

.

--