ML20207B518

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Rept 50-267/86-14 on 860512-16 (Ref 10CFR73.21).Violations Noted:Inadequate Personnel Access Control,Failure to Escort Visitors & Unbadged Person in Protected Area
ML20207B518
Person / Time
Site: Fort Saint Vrain 
Issue date: 06/19/1986
From: Caldwell R, Yandell L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20207B513 List:
References
50-267-86-14, NUDOCS 8607180089
Download: ML20207B518 (1)


See also: IR 05000267/1986014

Text

..

,

APPENDIX B

U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

NRC Inspection Report:

50-267/86-14

License:

DPR-34

Docket:

50-267

Licensee: Public Service Company of Colorado (PSC)

P. O. Box 840

Denver, Colorado, 80201

Facility Name:

Fort St. Vrain Nuclear Generating Station (FSV)

Inspection At:

Platteville, Colorado

Inspection Conducted: May 12-16, 1986

Inspector:

O

EA#

b9/f6

R.A.Caldwell,PpysicalSecuritySpecialist

Da te'

EmergencyPrepaddnessandSafeguards

Programs Sectior

Approved:

db

[p /3

L. 7. Yandell, Chief, Emergency Preparedness

D' ate

and Safeguards Programs Section

Inspection Summary

Inspection Conducted May 12-16, 1986 (Report 50-267/86-14)

Areas Inspected: Routine, unannounced inspection of physical barriers - vital

area (VA), access control

personnel, detection aids - VA, alarm stations,

security systems power supply, and communications.

Results: Within the six areas inspected, three violations were identified

(inadequate access control

personnel, failure to escort visitors, and

unbadged person in the protected area (PA), paragraph 3).

MCLOSURE 00NTAINS

SAFEGUARDS INFORMATION.

UPON SEPARATION THIS

PAGE IS DECONTROLLED.

8607180089 860710

l

PDR

ADOCK 05000267

G

PDR