ML20207A329

From kanterella
Jump to navigation Jump to search
Requests Review Meeting to Present Technical Results Demonstrating That Difficulty in Measuring Water Phase Pressure Resolved.No Fuel Coolant Interaction Tests Should Be Performed Until Problem Resolved
ML20207A329
Person / Time
Issue date: 07/23/1985
From: Telford J
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Berman M
SANDIA NATIONAL LABORATORIES
Shared Package
ML20207A169 List: ... further results
References
FOIA-86-678 NUDOCS 8611100212
Download: ML20207A329 (1)


Text

.

M2 3 1985 Dr. Marshall Bennan Sandia National Laboratories Division 6427 Albuquerque, NM 87185

Dear Dr. Beman:

According to the Technical Highlights / Administrative Report for April-May 1985, the difficulty of measuring water phase pressure continues.

I am concerned about this problem.

I make the following two-part official request.

1.

When this problem is resolved to your satisfaction, schedule a review meeting at SNL to present the technical results which demonstrate that the problem is solved. An appropriate audience will attend the review meeting.

2.

Do not perform any fuel coolant interaction tests or experiments until the water phase pressure measurement problems are solved, the review meeting has been held, and restart of testing has been approved by the NRC.

Please refer to Item 3 of the FY 1985 Program Brief for Fin No. A1030.

Sincerely, John L. Telford NRC Project Manager Containment Systems Research Branch distribution: circ; chron; Telford; Curtis; Morrison; Bassett; Ross; Minogue; Kelber; Wright; R.P. Anderson, ANL CSRB CSRB TELFOR$1m CURTIS 0741/86 07/ 385 7

8611100212 861030 4

hRA4

-678 PDR d@

- _.