Northern States Power Company 414 Nicollet Mall Minneapohs. Minnesota 55401 Telephone (612) 330-5500 July 1, 1986 Director Office of Nuclear Reactor Regulation U S Nuclear Regulatory Commission k'ashington,

DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Unit 1 Inservice Inspection Summary Report Attached for your review are four copies of the report, " Prairie Island Nuclear Generating Plant - Unit 1, Inservice Inspection - Examination Summary, March 8, 1986 to April 7, 1986".

This is the second inservice inspection conducted for inspection period one of the second ten year interval.

This report identifies the components examined, the examination methods used, the examination number and summarizes the examination results of each of the following areas:

1.

Pressure retaining components and supports of the reactor coolant and associated systems classified as ASME Class 1 and ASME Class 2.

2.

Eddy current examination of Steam Generator tubing.

Five tubes in No. 11 steam generator and ten tubes in No. 12 steam generator were mechanically plugged.

The evaluation of the results from the inservice examinations indicated that integrity of the systems has been maintained.

86071i0227 860701 DR ADOCK 05000282 0

PDR

\\

\\

Dir of NRR Northem States Power Company July 1.,

1986 Page 2 This report is being submitted in accordance with the Prairie Island ASME Code Section XI Inservice Inspection and Testing Program. As noted in that program, submittal of the attached summary is intended to satisfy the inspection reporting requirements contained in IWA-6220 of Section XI of the ASME Code.

)

b A as Davi Musolf Manager - Nuclear Suppor Services DMM/EFE/efe c: Regional Administrator-III, NRC (2 copies of attachment)

NRR Project Manager, NRC (1 copy of attachment)

Resident Inspector, NRC (w/o attachment)

G Charnoff (w/o attachment)

H Baron, Chief Boiler Insp., State of MN (1 copy of attachment)

S Tact, Hartford Ins. (1 copy of attachment)

Attc.chment

.