ML20206S601

From kanterella
Jump to navigation Jump to search
Application for Amend to License NPF-37,substituting Requirement to Measure source-range Neutron Flux Instrumentation High Voltage Plateau W/Discriminator Bias Curves.Fee Paid
ML20206S601
Person / Time
Site: Byron, Braidwood, 05000000
Issue date: 09/15/1986
From: Johnson I
COMMONWEALTH EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20206S605 List:
References
2100K, NUDOCS 8609220280
Download: ML20206S601 (2)


Text

a/

+.

c,ossissiostweelui Edloosi

.4 One Frat National Plaza, CNeago, Illinois

  • / Address Reply to: Post Omco Box 767 Nd CNcago, Illinois 60600 0767 l

September 15, 1986 Mr. Harold R.'Denton U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, DC.

20555

Subject:

Byron Station Units 1 and 2 Application for Amendment to Facility Operating License, NPF-37, Appendix A, Technical Specifications NRC Docket Nos. 50-454/455 and 50-456/457

Dear Mr. Denton:

Pursuant to 10 CFR 50.90, Commonwealth Edison proposes to amend Appendix A, Technical Specifications to Facility Operating License NPF-37, to make several changes. Tnis change substitutes the requirement to measure source range neutron flux instrumentation high voltage plateau with discrimi-nator bias curves. These proposed changes are listed in Attachment 1, and further described in Attachment 2.

The proposed changes have been reviewed and approved by both On-site and Off-site review in accordance with Commonwealth Edison Company procedures. We have reviewed these proposed amendments in accordance with 10CFR 50.92(c) and determined that no significant hazards considerations exist. Our evaluation is documented in Attachment 3.

These changes are applicable to Byron Unit 2 and Braidwood Units 1 and 2 and should be incorporated into the initial Braidwood Technical Specifications, if they are found to be acceptable.

Commonwealth Edison is notifying the State of Illinois of our application for this amendment by transmitting a copy of this letter and its attachment to the designated state official.

In accordance with 10 CFR 170, a fee remittence in the amount of

$150.00 is also enclosed.

8609220200 860915 PDR ADOCK 05000454 k

P pyg 90

\\

\\

gi / w aco' W/*00 c

Mr. H. R. Denton September 15, 1986 Please direct any questions you may have regarding this matter to this office.

Three (3) signed originals and thirty-seven (37) copies of this letter and its attachments are provided for your use.

Very truly yours, I. M. John Nuclear Licensing Administrator la cc: Resident Inspector-Byron L. Olshan - NRR J. A. Stevens - NRR M. C. Parker - IDNS i

Attachments 1: Proposed Changes to Appendix A Technical Specifications for Eyron Station Units 1 and 2 Facility Operating License NPF-37 2: Summary of Changes 3: Evaluation of Significant Hazards Consideration l

l SUBSCR ED and to before this day l

of YfntfuA, 1986 04A13 1

Notary Public'

[

2100K

-... -