Forwards Safety Insp Repts 50-151/87-01 & 50-356/87-01 on 870331-0402.No Violation Noted
ML20206S189
Person / Time
Site: 05000356, University of Illinois
Issue date: 04/16/1987
From: Shafer W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Bradley Jones
ILLINOIS, UNIV. OF, URBANA, IL
Shared Package
ML20206S194 List:
References
NUDOCS 8704220352
Download: ML20206S189 (2)


See also: IR 05000151/1987001

Text

_

.

.

-

APR 16 G87

Docket No. 50-151

Docket No. 50-356

University of Illinois

ATTN:

Barclay G. Jones, Ph.D.

Acting Head, Department of

Nuclear Engineering

l,

214 Nuclear Engineering Laboratory

'

103 S. Goodwin Avenue

Urbana, IL 61801

l

Gentlemen:

This refers to the routine safety ins)ection conducted by Mr. W. J. Slawinski

of this office during the period Marc 1 31 through April 2, 1987, of activities

at the University of Illinois Nuclear Reactor Laboratory authorized by NRC

Operating Licenses No. R-115 and No. R-117 and to the discussion of our findings

l

with you,- Drs. J. G. Williams and B. J. Micklich and others at the conclusion

l

oftheinspectionandtothetelephoneconversatIonwithMr.CraigPohlodon

l

April 14, 1987.

l

The enclosed copy of our inspection re) ort identifies areas examined during

the inspection. Within these areas, tie inspection consisted of a selective

'

examination of procedures and representative records, observations,

independent measurements and interviews with personnel.

No violations of NRC requirements were identified during the course of this

inspection.

In accordance with 10 CFR 2.790 of the Commission's regulations, a co)y of

this letter and the enclosed inspection report will be placed in the

iRC

Public Document Room.

,

l

l

u

!

4[g

I

ammump

G

m

o

.

AFR 16 G87

Docket No. 50-151

Docket No. 50-356

University of Illinois

ATTN:

Barclay G. Jones, Ph.D.

Acting Head, Department of

1

Nuclear Engineering

214 Nuclear Engineering Laboratory

103 S. Goodwin Avenue

Urbana, IL 61801

Gentlemen:

This refers to the routine safety inspection conducted by Mr. W. J. Slawinski

of this office during the period March 31 through April 2, 1987, of activities

at the University of Illinois Nuclear Reactor Laboratory authorized by NRC

Operating Licenses No. R-115 and No. R-117 and to the discussion of our findings

with you, Drs. J. G. Williams and B. J. Micklich, and others at the conclusion

of the inspection and to the telephone conversation with Mr. Craig Pohlod on

April 14, 1987.

.

The enclosed copy of our inspection report identifies areas examined during

the inspection.

Within these areas, the inspection consisted of a selective

,

examination of procedures and representative records, observations,

independent measurements and interviews with personnel.

No violations of NRC requirements were identified during the course of this

inspection.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and the enclosed inspection report will be placed in the NRC

Public Document Room.

@

J

\\

emome

O

m

_

_

_

.

.

,

University of Illinois

2

AFR 1 6 507.

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

M s h ed by y,3, g ,

W. D. Shafer, Chief

Emergency Preparedness and

Radiological Protection Branch

Enclosure:

Inspection Reports

No. 50-151/87-001 DRSS ;

No. 50-356/87-001 DRSS

cc w/ enclosure:

DMB/ Document Control Desk (RIDS)

Licensing Fee Management Branch

l

l

RIII

R

al:(I

Slawiysli)iTnma

W.6

\\

r

r

~

-

-

--- -

-

-

-

.

-

-

- -

-

-