ML20206S061
| ML20206S061 | |
| Person / Time | |
|---|---|
| Site: | Farley |
| Issue date: | 04/15/1987 |
| From: | Mcdonald R ALABAMA POWER CO. |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| Shared Package | |
| ML20206S065 | List: |
| References | |
| NUDOCS 8704220325 | |
| Download: ML20206S061 (1) | |
Text
r-.
4k4 Abb ma Power Company 600 F erth 18th Strat Post Offsce Box 2641 Birmingham, Alabama 35291-0400 Telephone 205 250-1835 l/dfle"g,,,em,
. AlabaillaPower
" S*" " 8*'"
Docket No. 50-364 10CFR50 Appendix H April 15, 1987 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C.
20555 Gentlemen:
Joseph M. Farley Nuclear Plant - Unit 2 Reactor Vessel Surveillance Capsule Report Pursuant to the requirements of 10CFR50 Appendix H and Technical Specification 3/4.4.10, Alabama Power Company herewith submits the Westinghouse WCAP-11438 report entitled " Analysis of Capsule W from the Alabama Power Company Joseph M. Farley Unit 2 Reactor Vessel Radiation Surveillance Program." This report presents the surveillance capsule test results from Capsule W, which were used to evaluate the reactor vessel
. material properties following 3.97 EFPY.
Based on the attached surveillance capsule test results, no technical change to' the existing Technical Specification is required and no changes to the operating procedures are required.
b Respectfully s mitted, 8704220325 870415 ALABAMA POW R COM ANY yDR ADOCK 05000364 PDR f
y R. P. Mcdonald j
RPM / MWD:csi-D400 l
Enclosure i
cc: Mr. L. B. Long Dr. J. N. Grace, w/1 enclosure Mr. E. A. Reeves Mr. W. H. Bradford
\\
lI L.