ML20206P909

From kanterella
Jump to navigation Jump to search
Forwards Form NRC-591,Safety Insp for Insp Conducted of Woodlawn Canners,Inc General License on 850904 & 05.Items of Noncompliance Noted
ML20206P909
Person / Time
Issue date: 10/30/1985
From: Wiedeman D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
WOODLAWN CANNERS, INC.
Shared Package
ML20206P912 List:
References
SSD, NUDOCS 9901130342
Download: ML20206P909 (4)


Text

_ __ ___

l I

AM 00T 3 01985 l

Woodlawn Canners, Incorporated 1292 Glendale /Milford Road Cincinnati, OH 45215 s

l, \\/

Gentlemen:

As a result of the inspection conducted on September 4 and 5,1985, a Form NRC-591, SAFETY INSPECTION, is issued for your NRC general license.

i The enclosed form sets forth the item of noncompliance noted.

Please acknowledge receipt of this form by signing and dating in the appropriate l

space on all copies.

You are requested to retain the original and return l

four signed and dated copies to this office within ten days.

l l

The enclosed ccpy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and telephone interviews with your personnel.

l If you have any questions or require clarification on any of the information stated above, you may contact us at (312) 790-5616.

l Thank you for your cooperation.

l l

Sincerely, I

t2 D. G. Wiedeman, Chief s

Nuclear Materials Safety

\\

l Section 1

\\

Enclosure:

As stated l

h j'

bec w/ enc 1:

N l

L. Cobb, OIE S. Baggett, NMSS

\\

i 9901130342 851030 RIII PDR RC SSD PDR Wiedeman/jp I

l 10/28/85

'e GENERAL LICENSE GAUGE DATA COLLECTION FORM 1.

Name and Address of General Licensee:

Woodlawn Canners,LIncorporated 1292 Glendale /Milford Road

. Cincinnati, OH 45215 (513) 771-9192

2..

Principal Business of Licensee:

< Canned Carbonated Beverages 3..

Purpose for which gauge (s) are used (e.g., measurement of level, density, flow, thickness, etc.):

Fill Control "4.

' Gauge' Specifics:

One gauge 1

a.

Manufacturer: Accuray Corporation

/.

b.

Model Number:

FLIR-201 Source Serial Number CS4826-772-f Y.

c.

Isotope / Activity:

cesium-137/14 millicuries I/

I d.

Date Received:

e.

Date Replaced: '1975 Gauge Specifics: 1Two gauges a.

Manufacturer:. Industrial Dynamics, Limited b.

Model Number:

Fil-Tec S/N 102795, Source S/N 633 Fil-Tec S/N 103364, Source S/N 1314 c.

Isotope / Activity:

Both~Fil-Tec units have americium-241/100 mil 11 curies d.

Date Received:

S/N 102795 - Unknown S/N 103364 - 1975 i

e.

Date Replaced:

5.

Name of specific licensee that installed gauge:

Accuray Corporation Gauge - Unknown Fil-Tec Gauges - Industrial Dynamics, Limited-6.

Does the gauge.have a durable, legible and visible label:

1 Yes, Fil-Tec Gauges 7.

Was an Initial Radiation Survey performed at time of installation and do they have a record (list results) NOTE:

records only required for 2

. year period:

Two years since insta11ation'

.--r

~,,,

)

1.

8.

Leak Tests:

a.

Have the tests been performed (list results):

Yes Less than 0.005 microcuries b.

Name of firm / person conducting test:

Indusi.'.al Dynamics, Limited / Mike Lee c.

Are records available of tests (list date of last test):

Yes NOTE:

records only maintained for 2 years Licensee has records only for October 30, 1984 and May 1, 1985.

Industrial Dynamics, Limited had records for May 26, 1981; August 23, 1982; October 11, 1983; October 30, 19894; and May 1, 1985.

1 9.

Operational Test of Gauge:

a.

Have any tests been performed of the on/off mechanism:

Yes, mechanism worked properly.

b.

Name of firm / person who performed test:

Industrial Dynamics, Limited / Mike Lee c.

Are records maintained of tests (list dates):

Yes, licensee had records only for October 30, 1984 and May 1, 1985.

10. Has the gauge been moved from it's original location? If so, by whom:

Accuray Corporation gauge was shipped to a new owner in Pennsylvania or New Jersey - Chroma 11y (sic) Beverage Company - in 1975.

Fil-Tec gauge S/N 102795 was moved by Industrial Dynamics, Limited from one production line to another in 1975 when Fil-Tec S/N 103364 was installed.

11.

Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c)

(1 through 10):

Rollin Brown 12.

Has the licensee made any transfers of gauges:

Accuray Corporation gauge was transferred to chroma 11y (sic) 8everage Company of either Pennsylvania or New Jersey Company.

4

i i,

l 13.

Name and Address of Gauge Manufacturer:

Accuray Corporation Industrial Dynamics, Limited 650 Ackerman Road 2927 Lomita Boulevard P.O. Box 02248 Torrance, CA 90509 Columbus, OH 43202 1

14. Onsite inspection of gauge (s) (list observations / measurements):

i l

l 15.

Name of ORAU Reviewer i

W $**H so.r*-17 Ki' chard C. Rookard Date 1

16.

Signature and Date of qviewer i

l 1

,,. 1 --

p-fo~ff l

DI G.-Wiedeman Date l

l l

l 5

I

.