Discusses GL 96-05 Issued on 960918 & NPPD Responses Submitted on 961118,970317,980504 & 990222 for Cooper Nuclear Station.Forwards Safety Evaluation Concluding That NPPD Adequately Addressed Actions Requested in GL 96-05
ML20206P017
Person / Time
Site: Cooper 
Issue date: 05/12/1999
From: Lawrence Burkhart
NRC (Affiliation Not Assigned)
To: Horn G
NEBRASKA PUBLIC POWER DISTRICT
Shared Package
ML20206P022 List:
References
GL-96-05, GL-96-5, TAC-M97035, NUDOCS 9905180124
Download: ML20206P017 (3)


Text

MM hit g

k UNITED STATES

.p g

j NUCLEAR REGULATORY COMMISSION

\\.....[&

WASHINGTON, D.C. 2006 Hoot May 12, 1999 Mr. G. R. Horn Sr. Vice President of Energy Supply Nebraska Public Power District 141415th Street Columbus, NE 68601 l

SUBJECT:

SAFETY EVALUATION OF LICENSEE RESPONSE TO GENERIC LETTER 96-05," PERIODIC VERIFICATION OF DESIGN-BASIS CAPABILITY OF SAFETY-RELATED MOTOR-OPERATED VALVES," COOPER NUCLEAR STATION (TAC NO. M97035)

Dear Mr. Horn:

On September 18,1996, the Nuclear Regulatory Commission (NRC) issued Generic Letter

' (GL) 96-05, " Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated

)

Valves," requesting each nuclear power plant licensee to establish a program, or to ensure the effectiveness of its current program, to verify on a periodic basis that safety-related motor-operated valves (MOVs) continue to be capable of performing their safety functions within the current licensing bases of the facility.

On November 18,1996, Nebraska Public Power District (NPPD) submitted a 60-day response to GL 96 05 notifying the NRC that it would implement the requested MOV periodic verification l/

1 program at the Cooper Nuclear Station (CNS). On March 17,1997, NPPETsubmitted a 180-day (l

response to GL 96-05 providing a summary description of the MOV periodic verification j

program planned to be implemented at CNS. In a letter dated May 4,1998, NPPD updated its

]

commitment to GL 96-05. On February 22,1999, NPPD provided a response to a request for additional information, dated October 28,1998, regarding GL 96-05, d

The staff has reviewed your submittals and applicable Inspection reports. The staff considers your commitment to implement the Joint Owners Group program to include all three phases of that program. NPPD is requested to notify the staff if its commitment differs from that understanding, Based on the understanding of NPPD's commitments with respect to GL 96-05, the staff finds that NPPD has established an acceptable program to verify periodically the design-basis

. capability of the safety-related MOVs at CNS. As discussed in the e

7001o gggB? 8MW 4

PDR y

_z

G. R Horn

-2 GL 96-05. The staff may conduct inspections t CN May 12, 1999 MOV periodic verification program is in accordan e y addressing the actions requested in a

S to verify that the implementation of the ce with NPPD's commitments.

Sincerely, ORIGINAL SIGNED BY Project Directorate IV & Decomm n1 Division of Licensing Project Management 5

Office of Nuclear Reactor Regulation 5

Docket No. 50-298

Enclosure:

Safety Evaluation cc w/ encl: See next page DISTRIBUTION:

Docket File (50-298)

PUBLIC PDIV-1 r/f S. Richards T. Scarbrough R. Norsworth K. Brockman,y (RCN)(SE only)

RIV ACRS OGC t

DOCUMENTNAME 1 f OFF CEto r c.w..emamem n:e p=:\\ COOPER \\LTR97035 WPD

  • No major changes to SE PDIV-1/PM iE PDIV-D/LA penclosure N No cop E *EMEB/SC f oDIV-1/S C NAME 1

LBurkhart:dbM CJamerson d/ DTerao k DATE RGramn\\b

/g S

/ 7 /g OFFICIAL RECORD COPY(g

G. R. Horn May 12, 1999 evaluation, the staff concludes that NPPD is adequately addressing the actions requested in

. GL 96-05. The staff may conduct inspections at CNS to verify that the implementation of the MOV periodic verification program is in accordance with NPPD's commitments.

Sincerely, ORIGINAL SIGNED BY Lawrence J. Burkhart, Project Manager, Section 1 Project Directorate IV & Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation l

Docket No. 50-298

{

Enclosure:

Safety Evaluation cc w/ encl: See next page DISTRIBUTION:

Docket File (50-298) j PUBLIC PDIV-1 r/f S. Richards T. Scarbrough R. Norsworthy (RCN)(SE only)

K, Brockman, RIV -

i ACRS OGC DOCUMENT NAME: 1:\\ COOPER \\LTR97035.WPD

  • No major changes to SE to r.c.w.. c= r or em oocum.nt m n c. do, c.c., e.ucw.nv.ncaw. e.c=y e.=c%nv.ncm-. y. No cov OFFICE PDIV 1/PM E

PDIV-D/LA E *EMEB/SC 6

PDIV-1/SC NAME LBurkhart:dbM CJamerson d' RGramnh DTerao

[ / // /99 5 / 7 /99b 4/16/99

(/W/99 DATE

~

OFFICIAL RECORD COPY

Cooper Nuclear Station cc:

Mr. John R McPhail, Genecal Counsel Lincoln Electric System Nebraska Public Power District ATTN: Mr. Ron Stoddard P. O. Box 499 1040 O Street

. Columbus, NE ^ 68602-0499 Box 80869 Lincoln, NE 68501 Nebraska Public Power District ATTN: Mr.J. H. Swalles MidAmerican Energy Vice President of Nuclear Energy ATTN: Dr. William D. Leech, Manager-Nuclear P. O. Box 98 907 Walnut Street Brownville, NE 68321 P. O. Box 657 Des Moines, IA 50303-0657 Randolph Wood, Director Nebraska Department of Environmental Nebraska Public Power District i

Control ATTN: Mr. B. L. Houston, Nuclear P. O. Box 98922 Licensing & Safety Manager j

Lincoln, NE 68509-8922 P. O. Box 98 I

Brownville, NE 68321 Mr. Larry Bohlken, Chairman Nemaha County Board of Commissioners Nemaha County Courthouse 1824 N Street Aubum, NE 68305 Senior Resident inspector U.S. Nuclear Regulatory Commission P. O. Box 218 Brownville, NE 68321 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 4

Arlington,TX 76011 Ms. Cheryl Rogers, LLRW Program Manager Division of Radiological Health Nebraska Departmsnt of Health 301 Centennial Mall, South P. O. Box 95007 Lincoln, NE 68509-5007 Mr. Ronald A. Kucera, Department Director of Intergovemmental Cooperation Department of Natural Resources

- P.O. Box 176 Jefferson City, MO 65102

..