.May 6, 1999-Mr. Jack Matlock, President Basic-PSA, Inc.
.124 Donald Lane -
Johnstown, Pennsylvania 15904
SUBJECT:
NRC INSPECTION REPORT 99901339/1999201 1
Dear Mr. Matlock:
. This letter addresses the inspection of your facility at'Johnstown, Pennsylvania, conducted by .
h Bill Rogers of this office on April 5 through 6,1999, and the discussions of his findings with you and other persons on your staff at the conclusion of the inspection.
Areas examined during the inspection are discussed in the enclosed report. This inspection consisted of an examination of procedures and representative records, interviews with ~
personnel, and observations by the inspector. During the review of your quality assurance program, within the scope of this inspect 6n, we found no instance in which Basic-PSA, Inc.,
failed to meet NRC requirements, however, a weakness was identified conceming the Basic-PSA, Inc.,10 CFR Part 21 procedure and its implementation.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and its enclosure will be placed in the NRC Public Document Room (PDR).
Sincerely,
/s/ !
Theodore R. Quay, Chief Quality Assurance, Vendor inspection, Maintenance and Allegations Branch Division of Inspection Program Management l Office of Nuclear Reactor Regulation _l 1
l Docket No. 99901339
Enclosure:
Inspection Report 99901339/1999201
.]
Distribution: I IQMB R/F / [
PUBLIC D- 1 I
Central Files / Docket File No. 99901339 DOCDESK (elec. file) ,9 g DOCUMENT NAME: G:\ DRAFT \ ROGERS \BASilNRE.WPD gg yh[
To receive a copy of this document. Indicate in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy b j OFFICE IQMB C ASC:lQMB C BC:lOMB NAME BRogers Z/4R GCwalinaf/64v TQuay 17W -
DATE- 5/5/99 5/6 /99 5/ (, /99 ,
OFFICIAL RECORD COPY 9905170067 990506 PDR GA999 EMV***** ,
99901339 PDR , ;
h w gesh