7 l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-1047-D-101-E DATE: Fby 10,1999 PAGE 1 OF 3 DEVICE TYPE: Ion.ization Smoke Detector MODELS: SMD1, 0805, 0905, 0906, 0908, 1225, 1255, and 200 Series l
DISTRIBUTOR: Walter Kidde Portable Equipment, Inc. I 1394 South Third Street l Mebane, NC 27302 l
MANUFACTURER: Fyrnetics (Hong Kong) LTD.
(Formerly Management Investment &
Technology Co. LTD) 7th Floor, Tin Fung Industrial Mansion 63 Wong Chuck Hang Road Aberdeen Hong Kong SEALED SOURCE MODEL DESIGNATION: Amersham Model A-1001 NRD Model A-001 ISOTOPE: MAXIMUM ACTIVITY:
Americium-241 1.0 microcurie (37 kBq)
LEAK TEST FREOUENCY: Not Required PRINCIPAL USE: (P) Ion Generators, Smoke Detectors CUSTOM DEVICE: YES X NO l
l
+
9905140234 990510 PDR RC
- SSD PDR
i REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
HQ&1 NR-1047-D-101-E DATE: Fby 10,1999 PAGE 2 OF 3 DEVICE TYPE: Ionization Smoke Detector DESCRIPTION:
Seven models of smoke detectors contain either a type 100A or 100B ionization chamber. All seven of these models share common tooling for plastic parts. Models utilizing either a 100A or 100B ionization chambers are models: SMD1, 0805, 0905, 0906, 0908, 1225, and 1255.
The 200 Series will be essentially identical in design and will use a type 200 chamber only and will not exceed stated dose rates at 5 cm (1.97") and 25 cm (9.84"). The ionization chamber is covered by a stainless steel shell that has 24 2 slotted louvers equally spaced with either a square edge or an edge with a radlus. The effective opening of each louver is no greater than 1 2 . 00 net by 10 . 2 mm ( 0 . 079 " by 0 . 402 " ) .
l All alarm / detectors will have plastic housings. The housing consists of plastic base and cover. The plastic housing will f size from 10.16 cm (4.00") to 17.78 cm (7.00"). The Series 200 {
includes models 0914, 0915, 0916, 0918, 1235, 1275, and 1285 and the applicant may distribute other models, meeting the requirements stated herein, as a part of the 200 Series classification. All models will have a thickness 1.587 mm (0.062") or greater and satisfy UL requirements. These tests include 5 drops from 2.13 m (7.00 ft), jarring test, and vibration tests. All future models will also be required to pass these tests. The plastic material used for the housing must also l comply with the UL requirements for flammability, temperature l
stability, and impact resistance.
Walter Kidde Portable Equiptent, Inc., Fyrnetics, Inc. and Fyrnetics (Hong Kong), LTD. are all within the Kidde International (UK), Fire Safety Products Group.
l
[
h :.
i i
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES j SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-1047-D-101-E DATE: Fby 10, 1999 PAGE 3 OF 3 DEVICE TYPE: Ionization Smoke Detector HEFERENCES:
The following supporting documents are hereby incorporated by reference and are made a part of this registry document.
- Fyrnetics' letters dated December 4, 1991, April 3, 1992, April 6, 1992, November 30, 1992, December 8, i 1992, September 26, 1995, April 2, 1996, and April 11, 1996, with enclosures thereto.
1
- Fyrnetics' letter received at the U.S. NRC on March 14, {
1992, with enclosures thereto. l
- Walter Kidde's application dated August 1, 1997, and !
letters dated January 20, 1998 (2 letters), January 23, !
1998, February 18, 1998, June 9, 1998, and February 8, i 1999, with enclosures thereto.
ISSUING AGENCY:
U.S. Nuclear Regulatory Commission Date: May 10, 1999 Reviewer: MM hw Michele LI' Burg"es bu ON Date: Fby 10, 1999 Concurrence: /
- ohn P. V Jankovich l
Q ]
1 i Lctry Ritzt:ff May 10, 1999 9 1 Product Engine .
Kidde Safety -- .
4980 Centennial Blvd.
Colorado Springs, CO 80919
Dear Mr. Ratzlaff:
)
l
~ Based on the information submitted in your amendment request dated February 8,1999, we l continue to conclude the Model 200 Series smoke detectos is acceptable for licensing purposes j
'in accordance with the conditions of the enclosed registration certificate (NR-1047-D-101-E); i
- Please be advised that you must manufacture and distribute the product in accordance with the statements and representations contained in your application, with enclosures thereto, and the information set out in your registration certificate.- As a general rule, you must request and obtain an amendment to the certificate before you make changes or modifications to the -
. information submitted to obtain the certificate.
PIAase read over the registration certificate in its entirety and notify us immediately of any errors or omissions. .)
l You are obligated to notify us promptly in writing Liould you decide to no longer manufacture or offer service support for the product.
- Please be aware that, as a holder of an NRC registration, you may be subject to the NRC's licensing fees in accordance with 10 CFR Part 170, and annual fees in accordance with 10 CFR ~
~
Part 171, if you have any questions concerning the fee requirements, please contact the l License Fee and Debt Collection Branch at (301) 415-6096.
If you have any questions, please contact me at (301) 415-5799 or Ms. Michele Burgess at l
.(301) 415-5868.
Sincerely,
/s/
Eric B. Compton, Engineering Aide ;
Materials Safety Branch Division of Industrial and Medical Nuclear Safety i
Office of Nuclear Material Safety And Safeguards
~
Enclosure:
As stated cc w/ encl: SKimberley, LFDCB AKirkwood, IMNS/MSB -
Distribution:
- IMNS r/f SSD-99120 NE0
. SSD File # NR-1047-D-101-E DOCUMENT NAME: H:\SSDFILES\ LETTERS \N1047101. CMP TS eseelwe o esp ' of this document. Indicate in the boa: "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" == No copy OFFICE : MSB [C MSB. l- l- l l NAME ECompton - FC. MBurgess 7#/A DATE- 03//C/99 OF//P/99 OFFICIAL RECORD COPY l?$ h ? !0 5 0 lf*
I REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES ,
SAFETY EVALUATION OF DEVICE i (AMENDED IN ITS ENTIRETY)
NO.: NR-1047-D-101-E DATE: May 10, 1999 PAGE 1 OF 3 1
DEVICE TYPE: Ionization Smoke Detector MODELS: SMD1, 0805, 0905, 0906, 0908, 1225, 1255, and 200 Series i
DISTRIBUTOR: Walter Kidde Portable Equipment, Inc. I 1394 South Third Street Mebane, NC 27302 MANUFACTURER: Fyrnetics (Hong Kong) LTD.
(Formerly Management Investment & !
Technology Co. LTD) l 7th Floor, Tin Fung Industrial Mansion 63 Wong Chuck Hang Road Aberdeen Hong Kong SEALED SOURCE MODEL DESIGNATION: Amersham Model A-1001 NRD Model A-001 l
ISOTOPE: MAXIMUM ACTIVITY: j l
Americium-241 1.0 microcurie (37 kBq) i l
LEAK TEST FREOUENCY: Not Required ;
PRINCIPAL USE: (P) Ion Generators, Smoke Detectors i
l CUSTOM DEVICE: YES X NO i
Bl#1t#T4o'134 '24 p
F R
>*. j i*- l
- l. 1
. REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE I
(AMENDED IN ITS ENTIRETY) 1 i
NO.: NR-1047-D-101-E DATE: May 10, 1999 PAGE 2 OF 3 i
. DEVICE TYPE: Ionization Smoke Detector.
DESCRIPTION:
Seven models of smoke detectors contain either a type 100A or 100B ionization chamber. All seven of these models share common tooling.for plastic parts. Models utilizing either a 100A or 100B ionization chambers are models: SMD1, 0805, 0905, 0906, 0908, 1225, and 1255.
The 200 Series will be essentially identical in design and will use a type 200 chamber only and will not exceed stated dose rates at 5 cm (1.97") and 25 cm (9.84"). The ionization chamber is covered by a stainless steel shell that has 2422 slotted louvers equally spaced with either a square edge or an edge with a radius. The effective opening of each louver is no greater than 2.00 mm by 10.2 mm (0.079" by 0.402").
All alarm / detectors will have-plastic housings. The housing !
consists of plastic base and cover. The plastic housing will '
size from.10.16 cm (4,00") to 17.78 cm (7.00"). The deries 200 includes models 0914, 0915, 0916, 0918, 1235, 1275, and 1285 and the applicant may distribute other'models, meeting the requirements stated herein, as a part of the 200 Series classification. All models will have a thickness 1.587 mm (0.062") or greater and satisfy UL requirements. These tests include 5 drops from 2.13 m (7.00 ft), jarring test, and vibration tests. All future models will also be required to pass these tests. The plastic material used for the housing must also comply with the UL requirements for flammability, temperature stability, and impact resistance.
Walter Kidde Portable Equipment, Inc., Fyrnetics, Inc. and Fyrnetics-(Hong Kong), LTD. are all within the Kidde International (UK), Fire Safety Products Group.
l l
^
1 i
L_
5 r
i
.'A-
~
' REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO21 NR-1047-D-101~-E DATE: May 10, 1999 PAGE 3 OF 3 DEVICE TYPE: Ionization: Smoke Detector.
1
REFERENCES:
The'following supporting documents are hereby incorporated by reference and are'made a part of this registry document
- Fyrnetics' letters dated December 4, 1991, April 3, 1992, April 6, 1992, November 30, 1992,-December 8,.
1992, September 26, 1995, April 2, 1996,'and April 11, 1996, with enclosures thereto.
- Fyrnetics' letter received at the U.S.'NRC on March 14, 1992, with enclosures thereto.
- Walter Kidde's. application dated August 1, 1997, and letters' dated January 20, 1998 (2 letters), January 23, 1998, February 18, 1998, June 9, 1998, and . February 8,
-1999, with enclosures thereto.
-ISSUING AGENCY:
U.S. Nuclear Regulatory Commission Date: May 10, 1999 Reviewer: Y/*M ha Michele Lf~ Burg'es Date: May .10,- 1999 Concurrence:
gohn P.Jankovich
May 10, 1999:
( + ;Ltrry'Ritzlaff, 4
Product Engine
, Kidde Safety
?4980 Centennial Blvd.; * '
Colorado Springs, CO 80919
Dear Mr. Ratzlaff:
Based on the information submitted in your amendment request dated ' ebruary 8,1999, we
. continue to conclude the Model 200 Series smoke detector is acceptabie for licensing purposes
- in accordance with the conditions of the enclosed registration certificate (NR-1047-D-101-E).
Please be advised that you must manufacture and distribute the product in accordance with the statements and representations contained in your application, with enclosures thereto, and the information set out in your registration certificate.- As a general rule, you must request and -
obtain an amendment to the certificate before you make changes or modifications to the information submitted to obtain the certificate.
Please read over the registration certificate in its entirety and notify us immediately of any errors Lor omissions.
You are obligated to notify us promptly in writing should you decide to no longer manufacture or offer service support for the product.
Please be aware that, as a holder of an NRC registration, you may be subject to the NRC's -
. licensing fees in accordance with 10 CFR Part 170, and annual fees in accordance with 10 CFR Part 171. If you have any questions concerning the fee requirements, please contact the License Fee and Debt Collection Branch at (301) 415-6096.
If you have any questions, please contact me at (301) 415-5799 or Ms. Michele Burgess at (301) 415-5868.
- Sincerely,
/s/
Eric B. Compton, Engineering Aide
' Materials Safety Branch Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety And Safeguards
Enclosure:
As stated cc w/ encl: SKimberley, LFDCB
' AKirkwood,IMNS/MSB' i . Distributiont
( . IMNS r/f SSD-99-20 NE0 L SSD File # NR-1047-D-101-E DOCUMENT NAMEi H:\SSDFILES\ LETTERS \N1047101. CMP
' T3 receive e cow of this document. Indcate in the bos: "C" = Copy without attachment / enclosure *E' = Copy with attachment / enclosure *N' = No copy OFFICE MSB lC. MSB l l l -l NAME. ECompton1 FC- MBurgess 7Ml/s DATE 03//C/99 - OY//P/99
. OFFICIAL RECORD COPY
,- $W0(db O
O REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY) l NO : NR-1047-D-101-E DATE: May 10, 1999 PAGE 1 OF 3 i DEVICE TYPE: Ionization Smoke Detector MODELS: SMD1, 0805, 0905, 0906, 0908, 1225, 1255, and 200 Series j I
l 1
DISTRIBUTOR: Walter Kidde Portable Equipment, Inc. ;
1394 South Third Street l Mebane, NC 27302 MANUFACTURER: Fyrnetics (Hong Kong) LTD. I (Formerly Management Investment &
Technology Co. LTD) 7th Floor, Tin Fung Industrial Mansion 63 Wong Chuck Hang Road Aberdeen Hong Kong SEALED SOURCE MODEL DESIGNATION: Amersham Model A-1001 NRD Model A-001 ISOTOPE: MAXIMUM ACTIVITY:
Americium-241 1.0 microcurie (37 kBq)
LEAK TEST FREOUENCY: Not Required PRINCIPAL USE: (P) Ion Generators, Smoke Detectorc CUSTOM DEVICE: YES X NO a d\ l t n W i r - QN1 vin sv< -
'M u
e l
REGISTRY OF. RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY) 1 NQ,: NR-1047-D-101-E DATE: May 10, 1999 I PAGE 2 OF 3 4 DEVICE TYPE: Ionization Smoke Detector DESCRIPTION: ,
I Seven models'of smoke detectors contain either a type 100A or l 100B ionization chamber. All seven of these models share common l tooling for plastic parts. Models utilizing either a 100A or ;
100B ionization chambers are models: SMD1, 0805, 0905, 0906, 0908, 1225, and 1255.
The 200 Series will be essentially identical in design and will use a type 200 chamber only and will not exceed stated dose rates at 5 cm (1.97") and 25 cm (9.84"). The ionization chamber is covered by a stainless steel shell that has 24*2 slotted louvers equally spaced with either a square edge or an edge with a radius. The effective opening of each louver is no greater than 2.00 mm by 10.2 mm (0.079" by 0.402").
All alarm / detectors will have plastic housings. The housing consists of plastic base and cover. The plastic housing will size from 10.16 cm (4.00") to 17.78 cm (7.00"). The Series 200 includes models 0914, 0915, 0916, 0918, 1235, 1275, and 1285 and the applicant may distribute other models, meeting the requirements stated herein, as a part of the 200 Series classification. All models will have a thickness 1.587 mm (0.062") or greater and satisfy UL requirements. These tests include 5 drops from 2.13 m (7.00 f t) , jarring test, and vibration tests. All future models will also be required to pass these tests. The plastic material used for the housing must also comply with the UL requirements for flammability, temperature stability, and impact resistance.
Walter Kidde Portable Equipment, Inc., Fyrnetics, Inc. and Fyrnetics (Hong Kong), LTD. are all within the Kidde International (UK), Fire Safety Products Group.
I 1
I
I o,.
E e-
-REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO,: NR-1047-D-101-E DATE: Phy 10,1999 PAGE 3 OF 3 DEVICE TYPE: ' Ionization Smoke Detector
REFERENCES:
The following supporting doc'iments. are hereby incorporated by reference and are made'a part oflthis registry document.
- Fyrnetics' letters dated December 4, 1991, April'3,
'1992, April 6, 1992,' November 30,1992, December 8, 1992, September 26, 1995,- April 2, 1996, and April 11, 1996, with enclosures thereto.
Fyrnetics'. letter received at the U'S. NRC on March 14, 1992, with enclosures'thereto.
- Walter'Kidde's' application dated August 1, 1997, and letters dated January 20,.1998 (2. letters), January 23,
-1998, February 18, 1998, June 9, 1998, and February 8, 1999, with enclosures'thereto.
ISSUING AGENCY:
'U.S.: Nuclear Regulatory Commission May 10, 1999 I/ M Date: Reviewer: >m*
Michele LI' Burg'es Date: Fby 10, 1999 Concurrence:
dfohn P.V Jankovich
/
I s r
>r.- . . ., ..
'. NRC FORM 567 U.S. NUCLEAR REGULATORY COMMISSION (1 1999)
REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send this rerquest AND a copy of all related letters / applications and drawings to the Chief Sealed Source Safety Section, OWFN Mail Stop 04 H3. Change the License Tracidng System rnilestone to 19 and assign th'risiesirer[Cobj'1-5','j Q: l!O NOTE: Retain a Copy of this request with the application and background files.
REQUESTER RF.UlUN/LOGATION.
Kidde Safety TELEPHONE NUMsER DATE l
] ll lil
] IV HQ ] LFARB TYPE OF ACTION REQUESTED (Check as appropriate)
Larry Ratzlaff SOURCE REVIEW Q AMENDMENT OFSHEET imL c6inROL NuusER(s) REGISTRATION DEVICE REVIEW NUMBER (S)
LDERMPPLidlTi N DATE ' .lCENSE NUMBER (S)
CUSTOM REVIEW NR-1047-D-101-E 02/08/1999 32-23858-01E COMMENTS.
4980 CENTENNIAL BLVD.
COLORADO SPRINGS, CO 80919 FOR SSSS USE ONLY REVEWER MODEL NUM8ERs NUMBER ASSKiNED Eric Compton Various 99-20 DATE RECENED DATE AS$KINED DATE To FEES 03/15/1999 03/15/1999 03/15/1999 TYPE OF ACTION (Indicate the number of each type)
Q COMMERCIAL DISTRIBUTION (FORMAL) [-] USE BY A SINGLE APPLICANT (CUSTOM)
SOURCE (9C) SOURCE (9A) SOURCE (90) SOURCE (98)
] NEW NEW NEW NEW D AMENDMENT Q AMENDMENT ] AMENDMENT C AMENDMENT NO SAFETY EVALUATION REQUIRED LICENSING ACTION
] NO FEES REQUIRED REQUIRED
] YES NO (IF KNOWN)
Q OTHER (Specify)
Received check #087064 in the amount of $610.00.
TOTAL NUMBER OF NOMS REVIEW HOURS Registration Certificate noted above being amended.
NUMBER OF DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS
' _ FOR FEE USE ONLY
- th .
FEE CATEGORT t'T Et 9A AMOUNT REC NED CHECK NUMBER 9B 9C
] 9D DATE Of CFECK LOG j }.d blo I D 0OObf" M -Ni OL4 b e&4 m
- g. -, RE-
'Sh ARC FORM 667 (11999) PMJNILD ON McLYLLED PAPLM The lurm was dea.gr ed wasng r* orma
-