ML20206L863

From kanterella
Jump to navigation Jump to search
Notification of Contract Execution,Mod 5,to Radiation Monitoring Program Requirements. Contractor:State of AR
ML20206L863
Person / Time
Issue date: 06/24/1986
From: Dorsey M
NRC OFFICE OF ADMINISTRATION (ADM)
To: Meyers D, Nicholas J
NRC, NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
CON-FIN-B-8500, CON-NRC-31-83-667 NUDOCS 8606300452
Download: ML20206L863 (1)


Text

Mb /

PbR NRC FOI.M 255 CONTRACT NUdeEO (10 761 NRC-31-83-667 Of vtSION OF CONTR ACTS MOOtF #C ATsON NUMBE R U.S. NUCLE AR REGUL ATOHY CCMMISSION Five (5)

WASHINGTON. O.C. 20555 ONEW G MODIF IC ATION l

OTHE R tSoctofvl NOTIFICATION OF CONTRACT EXECUTION CONTRACT BASED ON:

TO:

Dolores M. Meyers AUTHOR:2 ATPON NUMBE R Atinistrative Support Branch RFPA RG4-83-667 Office of Inspection & Enforcement Branch, RG-4 OATE to<oan soren) 3j3/es

/q-n) 6/24/86 CONTR ACT CH ANGES PE R THIS ACTION 5

FROM:

tcontract sorce sts f

to* '*'

Attachment No. 2, Statement of l Work is revised.

Small Purchases & Regional Operations Branch l

DIVISION OF CONTRACTS, ADM CONTRACTOR (Neme A Locerscal EXECUTION OATE Arkansas Department of Health 6/24/86 I

4815 W. Markham Street Little Rock, AR 72201 TYPE OF CONTRACT Cooperative Agreement PROJECT TITLE PE RIOO OF PE RFOnM ANCE l

Radiation Monitoring Program Fequirements 1/1/83 - 12/31/88 PRINCIPAL INVESTIGATOR Martin Tull NRC AUTHOR 12EO REPRESENTATIVE l

J. B. Nicholas 8&R NUMBER FIN NUMBER AMOUNT 94-19-30-20-1 B8500 NEW NRC FUNDS

_o_

FUNDING

8. hUNDING 13,700.00 TOTAL FY TOTAL NRC OBLIGATIONS s

49,950.00 GOVE RNME NT PROPE RTY ATT ACH ME N TISI:

N/A j

CONTR ACT OOCUMENT t I

NRC FORM 255

~

(10761 8606300452 E%O624 PDR CONTR NRC-31-83-667 PDR

h(J P!X60 I L--

DMTN RL c

~

.. CONI A Ac t 60 000t FA4L os pAu(5 AMENDMENT OF SOLICITATION /MODIFIC.ATION OF CONTRACT 3

l3

2. AML NDMEN TjenODiF aCAT TON NO.
3. LF F LCT evt OAT L
4. RE QU15t f GON/PVH CHA5E R EQ. NO.

S. PROJEC T NO. (J/ esipsace6ar a t////(

RG4-83 607 dtd 2/28/86 Five (S)

/

6. tSSULD ev

/ /

h ADMsNIST E REO ev gif other asian f rem di l

U.S. Nuclear Regulatory Coninission Division of Contracts 234Se %

t 3

Washington, DC 20555 4

P n..

3 LOD 4 eA. AMENOMENT OF SouCIT ATION NO.

R' EC"EIVE0

s. N AME AND' ADDRESS OF CONTRAC TOs4 (No.. erreet county. Asese end ZIP CdRe)

~

P.

as

~

@'.'. c,ad*O**L $

Arkansas Department of Health

,'l Division of Environmental Health Protection +.

Sy'

'* ^

'8" ira s sa 4815 W. Markham Street

%a. + 'O Little Rock, AR 72201 2 ^10. " ' '^ ' '

" " ' " ^ * ' ' " '"

X NRC-31-83-667 3oe. DATED (SEE ITKht iJ)

CODE l FACILITY CODE 2/9/83

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICIT ATiONS O.s not e..

The peow numbered solicatstson es amended as set forth en Iwm 14. Ttw hour and d.te specif ed for receipt of offers is entended.

Dndhd.

3 4

Oft:rs must ocknowledge rece.pt of this evendrrmot prior to the hour and date spectfed in the solicitation or es amended. try one of the foinowing methods:

(e) By corroiet.nr, f tems 8 and 15.and retuming -

copies of the amendment (b) By ackrowledging receipt of this emendment on each copy of the offer submitted; or (c) Er separem letter or telegram erhich inctuoos a rederence to the solicitation and e nendment numbers. FAILURE OF YOUR ACKNOWLEDG-MENT TO BE RECElVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN hEJECTION OF YOUR OFFER. If by virtue of this ammdment you desire to charge an offer already asbmitted.such change rney be rnede by miegram or letter.provided each toisgrem or notier makes reference to the solicitetson md this amendment. ersiis rocsind prior to the opening hour and dets specified.

32. ACCOUNT 4NG AND APPROPRsATeON DATA #f seee**d)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS / ORDERS.

IT MODIFIES THE CONTRACT / ORDER NO. AS DESCRIBED IN ITEM 14.

W ** TE*c'TTR OE'A n"o "s0 ES*YcE. *"*"*"' ' ' #'#'## ** **"* *

  • i D.THE ADOVE NUMSERED CONT A ACT/ ORDER R$ MODIFIED TO REFLECT THE ADMINfSTRATIVE CHANGES (seen as cheapee in paying ofth X

eparopreoison dear est.) SET FORTH IN ITEM 34. PURSUANT TO THE AUTHORITY OF F AR 43.lo3(D).

C. THIS SUPPLEMENTAL AGREEMENT #S ENTERE.D INTO PUR$UANT TO AUTHORITY OF:

D. OT HER (Speetfy type of nied4/leesson and en shority)

E. IMPORTANT: Contractor is not. b is required 10 sign this docurnent and return 3

Copies to the issuing office.

&w. DESCR6PTsON OF AMENOMENT/heOQiF 6 CAT 60N (Orsoneaed by UCF eeeenen headanse. incia.deng solacitation/ con creet estpect metter sehere f.esible.)

Delete ATTACHMENT 2 entitled " DETECTION CAPABILITIES FOR ENVIRONMENTAL SAMPLE ANALYSES" of ATTACHMENT A, STATEMENT OF WORK, and replace it with the attached ravised ATIACfNENT 2.

This modification does not change the ceiling amount of this cooperative agreement which remains unchanged at $79,250.00.

I g.,oroei.e.

r,.,.. ;

i.,m. no. c <ii o, ir,...c t.. r.ac ia nem.A - n o A... a.r.io or. ca.n......m.ie.

ca..

in f,n, orc.

1SA. NAME AND TITLE OF SIGNER (rype orprint) 16A. NAME AND TlT LE OF CONT RAC14NG OF FICER (Type orprint)

Ben N. Saltzman, M.D.

Director Paul J. Edgeworth w A n

ISS. CO K TO F

15c.DATE NED 168. UN 05 T

A 8 A 16C.DATE 51GNED ll//f BY f

-- N W "d-A.

/.

MM e

tssanoffe et CoKrpuf tsnr Ott> cert

/ //

'tstnertire'otterson e.,typtsid to esens

~

v v

v

.~..............

pap e -rvo'it o c3Y7 __-.

i REVISE 0 l

ATTACHMENT 2 OETECTION CAPABILITIES FOR ENVIRONMENTAL SAMPLE ANALYSES LOWER LIMIT OF DETECTION (LLD) a,g h i

Airborne Fish, Meat Water Particulate or Gas or Poultry Milk Food Products Sediment Analysis (pCi/1)

(pCi/m )

(pCi/kg, wet) (pCi/l) (pCi/kg, wet) (pCi/kg. dry)

D gross beta 4

1.0E-02 h

2000 D

1000 f

54 d

60' 100 Mn 15 1.0E-02 130 f

59 d

80' 200 Fe 30 2.0E-02 260 I

58 d

50' 100 Co 15 1.0E-02 130 f

60 d

50' 200

{

Co 15 1.0E-02 130 f

j 65 d

60' 200 2n 30 2.0E-02 260 f

95 d

80' 200

)

2r 30 2.0E-02 95 d

80' 200 Nb 15 2.0E-02 131 c

3 3

7.0E-02 1

60 200 134Cs 15 5.0E-02 130 15 60 150 p

137Cs 18 6.0E-02 150 18 80 180 140 d

f l

Ba 60 2.0E-02 60 60' 200 i

I j

140 d

La 15 2.0E-02 15 60' 200 i

r

)

i i

t f

1. ' -

ATTACHMENT 2 (con't) a.

The LLD is defined, for purposes of these specifications, as the smallest concentration of radioactive material in a sample that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.

It should be recognized that the LLD is defined as an a priori (before the fact) limit representing the capability of a measurement system and not as a posteriori (after the fact) limit for a particular measurement. Analysis should be performed in such a manner that the stated LLD's will be achieved under routine conditions.

These detection levels should be used as minimum criteria for objectives for instrumentation and analytical procedure selection.

For a particular measurement analysis (which may include radiothemical separation):

4.66 sb LLD=

E'V 2.22 Y

exp(-AAT) where:

LLD is the "a priori" lower limit of detection as defined above (as picocuries per unit mass or volume),

s is the standard deviation of the background counting rate or of the b

counting rate of a blank sample as appropriate (as counts per minute),

E is the counting efficiency (as counts per disintegration),

V is the sample si2E (in units of mass or volume),

2.22 is the number of disintegrations per minute per picocurie, Y is the fractional radiochemical yield (when applicable),

/( is the radioactive decay constant for the particular radionuclide, and 4T for environmental samples is the elapsed time between sample collection (or end of the sample collection period) and time of counting.

Typical values for E, V, Y, and T should be used in the calculations.

b.

LLD for drinking water.

c.

LLD for drinking water samples.

If no drinking water pathway exists, the LLD of gamma isotopic analysis may be used.

i

I: v.1 i

l ATTACHMENT ? (con't) sample counted for a minimum of 1000 3

Detection limit based on a 300 m (This detection limit is not a d.

minutes using a Ge(Li) detector.

requirement of the cooperative agreement, but should be considered as a goal.)

Detection limit based on a 1000 gram sample counted for a minimum (This detection limit is not a e.

minutes using Ge(Li) detector.

requirement of the cooperative agreement, but should be considered a goal.)

Detection limit based on a 1 kilogram sample counted for a minimum (This detection limit is not a f.

minutes using a Ge(Li) detector.

d as a requirement of the cooperative agreement, but should be considere

\\

goal.)

This does not mean that only the radionuclides listed in Attachment 2 a Other peaks which are measurable and g.

to be detected and reported. identifiable, together with the above liste identified and reported.

This table reflects the values given in the NRC D 1

h.

i i

i c

J h

l 4

y I

i i

L

..