Babcock & Wilcox

"**%*o"o'n.*.'.*.' c'n'"c'."Of*' "

yn a McDermott company P. O. Box 11165 Lynchburg, Virg;nia 24506-1165 June 24, 1986 (804) 522-6000 Standardization and Special Projects Branch Division of Licensing NRR U. S. Nuclear Regulatory Commission Washington, DC 20555 Attention: Mr. Harold Bernard

Subject:

Replacement Table 2-1 Gentlemen:

My letter to you dated June 3,1986, forwarded additional information for the Final Survey Report for the CX-10 License. The Table 2-1 information does apply to the CX-10 areas specifically. The attached replacement Table 2-1 provides the applicable information.

Very truly yours, BABC0CK & WILC0X Lynchburg Research Center Arne F. Olsen Senior License Administrator jhc Attachment pc: Director Region II, U S Nuclear Regulatory Commission Suite 2900 101 Marietta Street, NW Atlanta, GA 30323 0

8606300362 860624 PDR ADOCK O O3 l6 l l

o y

SUPPLEMENT NO. 1 TO LICENSE TERMINATION SURVEY REPORT FOR THE CX-10 CRITICAL EXPERIMENT FACILITY TABLE 2-1

SUMMARY

OF FINAL GAMMA SURVEY RESULTS Location Instrument Readings Number <----PRM-7--->

<---RSS-111--->

of Grids AVE MAX AVE MAX (nR/hr) t Bay 2 Walls & Floor 7.0 9.0 9.3 10.7 201 CX-10 Control Room 8.8 9.0 10.9 11.8 15 Utility Room 10.0 11.0 12.3 12.5 27 -

Labyrinths 9.0 9.0 9.8 10.2 36 Laboratories 9.1 10.6 10.9 12.8 75 offices 10.6 15.0 11.9 14.2 31 Hallways 9.0 9.0 11.4 12.8 17 Waste Tank (RLWHT) 9.9 18.0 11.0 11.5 126 Miscellaneous 9.5 9.5 10.7 11.5 4

Outside (Walls)

'17.2 24.0 12.0 13.7 21 Outside (Roof) 26.3 30.0 11.9 13.9 61 Outside (Ground) 20.6 40.0 12.5 17.6 381 Average 14.6 11.5 Maximum 40.0 17.6 Total 945 PRM-7 does not measure true dose equivalence over all energy ranges. These data are provided for information only.

2-3 l