{{#Wiki_filter:, SEABROOK STATION ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT For the Period January - December 1998 poril 1999 Prepared By: North Atlantic Energy Service Corporation Environmental Sciences Seabrook Station and Duke Engineering & Services Environmental Engineering Department Bolton, Massachusetts 01740 i
)
j 9905110255 990430 PDR ADOCK 05000443 i R PDR . l
t-TABLE OF CONTENTS i l l l Section Page j l l EXECUTIVE
SUMMARY
ii l LIST OF TABLES 111 LIST OF FIGURES iv
1.0 INTRODUCTION
............................................ 1 2.0 ENVIRONMENTAL MONITORING PROGRAM. . . . . . . . . . . . . . . . . . . . . . . 2 I l i 3.O 1
SUMMARY
OF RADIOLOGICAL ENVIRONMENTAL DATA.............. 13 A. Air Particulate..................... ................ 14 j B. Charcoal Filter...................................... 22 j L C. Milk................................................. 24 l l D. Surface Water........................................ 31 . [ E. Ground Water............. ............;.............. 34 ! h F. Sediment............................................. 39 l G. Fish............................. ................... 42 H. Lobsters............................................. 45 ; I. She11 fish............................,............... 48 j J. Irish Moss........................................... 51 ! K. Fo o d c r o p s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 K. Direct Radiation..................................... 57 4.0 QUALITY ASSURANCE PROGRAM............................... 78 5.0 LAND USE CENSUS......................................... 89
6.0 REFERENCES
.............................................. 91 ) 4 l 1 1
- )
I Exscutiva Summary The Radiological Environmental Monitoring Program for Seabrook Station operated with several unplanned interruptions for the period of January through December 1998. Samples collected as part of the radiological environmental program , included air particulates, charcoal filters, milk, ground water, surface ! (sea) water, sediment, fish, lobsters, shellfish, vegetation and direct radiation. Radiological analysis on all samples included that'for gamma and/or beta radiation. Any variability observed in the data is based primarily on a number of natural variables that can influence background radiation. The radionuclides identified as naturally occurring are K-40, Be-7, Th-232 and its daughter products. Cesium-137 was detected in milk as the result of fallout from atmospheric nuclear weapons testing. The levels detected are consistent with those measured during the , preoperational phase of the monitoring program. I During 1998, Seabrook Station had a unit capacity factor of 82.74. This capacity factor takes into account four forced outages during the year. The first forced outage was a continuation from 1997 and accounted for 16.39 days in 1998. The remaining forced outages encompassed 30, 12.14 and 2.46 days respectively. In 1998, the maximum whole body dose to the hypothetically exposed individual was .0197 millirem. This whole body i dose is the sum of all the exposure pathways for liquid and gaseous effluents, plus the direct whole body dose from station operations. This i total dose represents approximately 0.08% of the whole body dose limit for l a member of the public as set forth in 40CFR190. The complete calculational methodology is submitted to the NRC as part of the Annual Radioactive Effluent Release Report. l 11 4
LIST OF TABLES Number Title Page 2.1 ' Radiological Environmental Monitoring Program 3 2.2 Radiological Environmental Monitoring Locations 4 3.1 Environmental TLD Measurements................ 58 4.1 Sumnary of Process Control Analysis Results... 81 4.2 Sumnary of EPA Intercomparison Analysis Results 82 4.3 Sunnary of DESEL/Analytics crosscheck Results. . 84 4.4 Sunnary of Blind Duplicate Samples Submitted . . 87 4.5 Sunnary of Blind Duplicate Results . . . . . . . . . . . . 88 5.1 Land Use Census Results....................... 90
.)
t l iii i l i 4 (. i L. J
l F LIST OF FIGURES Number Title Page 2.1 Radiological Environmental Monitoring Locations Within 4 Kilometers of Seabrook Station............... 7 2.2 Radiological Environmental Monitoring Locations Between 4 Kilometers and 12 Kilometers from Seabrook Station...................................... 8 2.3 Radiological Environmental Monitoring Locations Outside 12 Kilometers of Seabrook Station............. 9 2.4 Direct Radiation Monitoring Locations Within 4 Kilometers of Seabrook Station........................ 10 2.5 Direct Radiation Monitoring Locations between 4 Kilometers and 12 Kilometers from Seabrook Station.. 11 2.6 Direct Radiation Monitoring Locations Outside 12 Kilometers of Seabrook Station ..................... 12 3.1 Gross Beta Measurements of Air Particulate Filters..... 15 3.1.1 Gross Beta Quarterly Averages 1985-97 (AP 01,02,03,06) 16 3.1.2 Gross Beta Quarterly Averages 1985-97 (AP 04,05,06).... 17 3.1.3 Gross Beta Quarterly Averages 1985-97 (AP 07,08,06).... 18 3.2 Gross Beta Quarterly Average Air Particulate Filters... 19 1992-1997 Indicators vs. Control 3.3 Cesium-137 in Milk (Stations TM-04, 09, 15)............ 22 l 3.3.1 Cesium-137 Annual Average Concentrations 1985-1997 (TM-04, 09, 15)....................................... 26 3.4 Cesium-137.in Milk (Stations TM-16, 20, 21)............ 27 i 1 1 3.4.1 Cesium-137 Annual Average Concentrations 1985-1997 l l (TM-16, 20, 21)........................................ 28 3.5 Gross Beta Measurements of Ground Water................ 35 i 3.5.1 Gross Beta Measurements of Ground Water Semi-Annual Averages 1985-1997..................................... 36 3.6 Environmental Radiation Measurements, TL 01-05........ 60 3.6.1 Environmental Radiation Measurements, 1985-1997 TL-01, 02, 03, 04, 05 ............................... 61 l f l 3.7 Environmental Radiation Measurements, TL 06-10......... 62 3.7.1 Environmental Radiation Measurements, 1985-1997 TL-06, 07, 08, 09, 10 ................................ 63 3.8 Environmental Radiation Measurements, TL 11-15......... 64 3.8.1 Environmental Radiation Measurements, 1985-1997 TL-11, 12, 13, 14, 15 ................................. 65 iv 1 J
I l i l l l i 3.9 Environmental Radiation Measurements, TL 16-20......... 66 ? 3.9.1 Environmental Radiation Measurements, 1985-1997 T1-16, 17, 18, 19, 20 ................................. 67
'3.10 Environmental Radiation Measurements, TL 21-25......... 68 3.10.1 ' Environmental Radiation Measurements, 1985-1997 TL-21, 22, 23, 24, 25 ................................. 69 3.11 Environmental Radiation Measurements, TL 26-30......... 70 3.11.1 Environmental Radiation Measurements, 1985-1997 !
TL-26, 27, 28,-29, 30.................................. 71 3.12 Environmental Radiation Measurements, TL 31-35......... 72 3.12.1 Environmental Radiation Measurements, 1985-1997 4 TL-31, 32, 33, 34, 35 ................................. 73 l l 3-13
. Environmental Radiation Measurements, TL 36-40......... 74 3.13.1 Environmental Radiation Measurements, 1985-1997 TL-36, 37, 38, 39, .................................... 75 3.14 Environmental Radiation Measurements, TL 41-47......... 76 3.14.1- Environmental Radiation Measurements, 1985-1997 TL-41, 42, 43, 44, 45, 46, 47 ......................... 77 l
i l l l l
\
\ l 1 I v J
g ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 1.0 Introduction The North Atlantic Energy Service Corporation's (NAESCO) Radiological Environmental Monitoring Program at Seabrook Station has been designed and carried out to achieve the following specific objectives: To provide an indication of the appearance or accumulation of any radioactive material in the environment caused by the operation of the nuclear power station. To provide assurance to regulatory agencies and the public that the station's environmental impact is known and within anticipated limits. To verify the adequacy and proper functioning of station effluent controls and monitoring systems. To provide standby monitoring capability for rapid assessment of risk to the general public in the event of unanticipated or accidental releases of radioactive material. North Atlantic Energy Service Corporation collected the terrestrial samples. Normandeau Associates, Inc. collected the marine and sediment samples. After initial processing,.the samples were sent to the Duke Engineering & Services Laboratory (DESL) in Westboro, Massachusetts for further processing and radionuclide analysis. The DESL also processed the environmental thermoluminescent dosimeters- (TLD's) . This report is a summary of the findings of the Radiological Environmental Monitoring Program for 1998. It is being provided in compliance with plant Technical Specification 6.8.1.3. 1 1 1
)
2.0 Envirenmental Monitoring Progrrm In this section, Table 2.1 outlines the monitoring program as required by Plant Technical Specification 3/4.12.1. Table 2.2 lists the operational sampling stations and their specific locations (distances are measured from the center of the Unit 1 Containment Building). The sampling locations are shown on maps in Figures 2.1 through 2.6 Below are listed the two-letter media codes and what they represent: AP Air Particulate CF Charcoal Filter TM Milk WG Ground Water WS Surface (Sea) Water SE Sediment TH Fin fish HA Lobsters MU Mussels (Shellfish) TL Direct Radiation (TLD) AL Irish Moss TF Food Crop 2
i I l Tabla 2.1 l Radiological Environmental Monitoring Program Media Sampling Frequency Required Analyses Air Particulate (AP) -Weekly Gross Beta I
-Quarterly Composite Gama spectroscopy Charcoal Filter (CF) -Weekly I-131 Milk (TM) -Monthly; semimonthly Gama spectroscopy When animals I-131 Are on pasture l
Surface (Sea) Water (WS) -Monthly Gama spectroscopy <
-Quarterly Composite H-3(composite) 1 Sediment (SE) -Semiannually Gamma spectroscopy Fish & Invertebrates -Seasonal or Gama spectroscopy (FH, HA, MU) -Semiannually Direct Radiation (TL) -Quarterly Integrated gamma j exposure 1
Irish Moss (AL) -Semiannually Gamma Spectroscopy Ground Water (WG) -Quarterly Gama Spectroscopy Gross Beta H-3 Food Crops (TF) -Monthly / Growing Season Gamma Spectroscopy l l l l l l l 1 ( 3
.J
Table 2.2 Radiological Environmental Monitoring Locations 1998 Distance From Direction Station Code . Station Plant From (Media - Sta. No.) Description Zone * (km) Plant AP/CF-Ol+ PSNH Barge Landing Area 1 2.7 ESE AP/CF-02+ Hampton Marina 1 2.7 E AP/CF-03+ Southwest Boundary 1 0.8 SW AP/CF-04+ West Boundary 1 1.0 W AP/CF-05 Winnacunnet High School 1 4.0 NNE AP/CF-06+ Georgetown Substation 2 24.0 SSW AP/CF-07 PSNH Substation 1 5.7 NNW AP/CF-08 EEH Substation 1 3.4 SSE TM-04+ Salisbury, MA 1 5.2 SW TM-08+ Hampton Falls, NH 1 4.3 WNW TM-09+ Hampton, NH 1 5.5 NNW TM-15 Hampton Falls, NH 1 7.0 NW TM-16 Kensington, NH 1 7.7 WNW TM-20+ Rowley, MA 2 16.3 S TM-21 North Andover, MA 2 29.0 SW WG-01 Seabrook Town Wells 1 5.6 W WG-04 Seabrook Station Well No.4 1 1.0 N WG-13 Seabrook Station Well No.13 1 1.0 N WS-01+ Hampton-Discharge Area 1 5.3 E WS-51+ Ipswich Bay 2 16.9 SSE SE-02 Hampton-Discharge Area 1 5.3 E SE-07+ Hampton Beach 1 3.1 E SE-08 Seabrook Beach 1 3.2 ESE SE-52 Ipswich Bay 1 16.9 SSE SE-57 Plum Island Beach 2 15.9 SSE FH-03+ Hampton-Discharge Area 1 4.5 ESE FH-53+ Ipswich Bay 2 16.4 SSE HA-04+ Hampton-Discharge Area 1 5.5 E HA-54+ Ipswich 2 17.2 SSE MU-06+ Hampton-Discharge Area 1 5.2 E MU-09 Hampton Harbor 1 2.6 E MU-56+ Ipswich Bay 2 17.4 SSE MU-59 Plum Island 2 15.8 SSE AL-05 Hampton-Discharge Area 1 5.2 E AL-55 Ipswich Bay 2 17.4 SSE 4 L
i Table 2.2 (Cont'd) Radiological Environmental Monitoring Locations , 1998 ' Distance From Direction Station Code Station Plant From (Media - Sta. No.) Description Zone * ( km) Plant TL-1+ Brimmer's Lane, I 1.1 N Hampton Falls TL-2+ Landing Road, Hampton I 3.2 NNE TL-3+ Glade Path, Hampton Beach I 3.1 NE TL-4+ Island Path, Hampton Beach I 2.4 ENE TL-5+ Harbor Road, Hampton Beach I 2.7 E TL-6+ PSNH Barge Landing Area I 2.7 ESE TL-7+ Cross Road, Seabrook Beach I 2.6 SE TL-8+ Farm Lane, Seabrook I 1.1 SSE TL-9+ Farm Lane, Seabrook I 1.1 S TL-10+ ' Site Boundary Fence I 1.0 SSW TL-11+ Site Boundary Fence I 1.0 SW TL-12+ Site Boundary Fence I 1.0 WSW TL-13+ Inside Site Boundary I 0.8 W TL-14+ Trailer Park, Seabrook I 1.1 WNW TL-15+ Brimmer's Lane, I 1.4 NW Hampton Falls TL-16+ Brimmer 's Lane I 1.1 NRW Hampton Falls TL-17+ South Road, North Hampton 0 7.9 N TL-18+ Mill Road, North Hampton 0 7.6 NNE TL-19+ Appledore Avenue, 0 7.9 NE North Hampton TL-20+ Ashworth Avenue, 0 4.1 ENE Hampton Beach TL-21+ Route 1A, Seabrook Beach 0 3.7 SE TL-22+ Cable Avenue, Salisbury 0 7.6 SSE Beach TL-23+ Ferry Road, Salisbury 0 8.1 S TL-24+ Ferry Lots Lane, 0 7.2 SSW Salisbury TL-25+ Elm Street, Amesbury 0 7.6 SW TL-26+ Route 107A, Amesbury 0 8.1 WSW .TL-27+ Highland St. S. Hampton 0 7.6 W TL-28+ Rte. 150, Kensington 0 7.9 WNW TL-29+ Frying Pan Ln., Hampton Falls 0 7.4 NW TL-30+ Route 150, Hampton 0 7.9 NNW i 5
l' l o l Table 2.2 (Cont'd) Radiological Environmental Monitoring Locations 1998 I l l Distance From Direction Station Code Station Plant From (Media - Sta. No.) Description Zone * (km) Plant TL-31+ Alumni Drive, Hampton S 4.0 NNE TL-32+ Seabrook Elementary School S 1.9 S TL-33+ Dock Area, Newburyport S 9.7 S TL-34+ Bow Street, Exeter S 12.1 NW TL-35+ Lincoln Ackerman School S 2.4 NNW TL-36+ Route 97, Georgetown 2 22.0 SSW TL-37+ Plaistow, NH 2 26.0 WSW TL-38+ Hampstead, NH 2 29.0 W TL-39+ Fremont, NH 2 27.0 NW TL-40+ Newmarket, NH 2 24.0 NNW TL-41 Portsmouth, NH 2 21.0 NNE TL-42 Ipswich, MA 2 27.0 SSE TL-43 Education Center S 0.3 ENE TL-44 Rocks Road Landing S 0.5 SW TL-45 Hampten Fire Station S 4.5 NE TL-46 Seabrook Beach S 2.9 ESE TL-47 Hampton Falls, NH S 4.2 WNW '
*1 = Indicator Stations; 2 = Control Stations; O = Outer Ring TLD; I = Inner Ring TLD; 3 = Special Interest TLD + = Sample Locations Required by the Off-Site Dose Calculation Manual (ODCM) 6
7nmrawwr s r, s
, y. ,
f', \ ] -
/N[ ; ~'
Jg/c7 A!
.g,- % ,/ -
X, ,,/ 3 L
,r j 4 . . , ,'9 w_ / ,, \' 'q #,w .r =vr Q , %, H 5 ' i d %.l ,'wW r ~ M )n #,, (l!
u a, N_i- -
.~_ 7 v s w
g-j r ( m
+- plA r,, c_?'y, s \sr s, i
( s .w
- ~1g g pf' QF [ / l< , 'Q ;; y J 74/ ~'
WG-13,04 T
- ~%; 3 ,- -
x A _s %
/ , ~ / ;_;m ., Seabro tC i % ~ sf., /- N(
AP/ f'- _/
-04 h hij ~
s v q_ b ~. t.. _. s
-s 1
g i
'AP/CFfm03 4 - ~-. C. - ; r- / ,
v
? ./ ,,.
v " %.-_-. . .f . x ,s . . s m L~/ x/sC
. s > - \
Ry )
\
s ; -.4%=} s 1 N (r-' x
-W < \
y! - \" , a- ,- eabr/OOk-(/ \ (N /s /[ '~
~
x .
~~~<
d - 86 1A
~ '~
i:e _y % ./
,/ *J'~ ,
w
/
h' ~qN.g' - - ~ /, [ j
./ ,~' t /CF-p8'j i - ~ , , =
i
'(" '
l ,'
'Y "]/ / \ ~ ,i ,, \
s' ,c;j f S alisbury
'N x ~x, s -,v
(' / -
; -4 L
m ,1mPjg_C,v b i i ~ c--
.p i -- . m l
Preasen Mepprg cosyteht 1996,96. Just Sofhuorks Inc., Portene Copyright 19821996 mUS.Inc. ! I l I l FIGURE 2.1 RADIOLOGICAL ENVIRONNENTAL MONITORING LOCATIONS WITHIN 4 KILOMETERS OF SEABROOK STATION 7 , 1 J
- 70 Sir 59". 4300 57" I
( ^ l
' Exeter l
l Radiological Envi j Monitoring AP/CFM Between 4 & A AP/CF-05 i A A TM-09 J M-08 I TM-15 A ' A A O (.) TM-16 WG-01 cea O , l%, A TM-04
's '
y '" l
,, ,/ \ Salisbury
,Mw . FIGURE 2.2 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS BETWEEN 4 KILOMETERS AND 12 KILOMETERS FROM SEABROOK STATION 8
N
? N l ' < \
( _ . ,
's, ) ,b g ~~ ,,/ 'a. ,/
f01c
\_ m N m i , "'*%:n Q I %% s1 (Oosn y Q.'S ,I ;w / \
, /
, ,~' #_V v - }/ * ,,
1 i i
/
y
' J , - -
lj'
./
l
> ' ,/
y I {
- ~~ 9e s <
s j l
- _./ ~/
M as ,~~ N. 4 l un l
~' 'm \ / ,j ,.-
i 7.-
/ '
r' %. i i
,s '
ml 18es. . w., FIGURE 2.3 Radiological Environmental Monitoring Locations Outside 12 Kilometers ofSeabrook Station
- m u 11. c se w i a 3 /,,, 3D / /p/ i / ? ,7 d%
v y^ N , ,fs,N
/ 'y q ',
4, l J\ ' s s y L._7 t eF y'd;g
~.L .1 \' l
__/ , L Q'/ ,'N, p _'G u
' I' y n. / >, 4 p \ > 'g T '
Klj%p ,
\ '/ ,- ' f~ >02 >~
L
. ) , ,L~~'d 9v / e p
c;3 L-g~3 > ' 3 x h_ / Jn vs ,- ,l'[TTL v _ _ . _
' ~
j '-r _.
/
f T A q 7d ,y 7 .2;L-15 TL,-01 Eb vL_cf TL-14A~'
'ehb ~
S g' -t TL:1-A' g
@b V W Cc z 'TL-12 ~
w
- v^T' L A
jTL-44
- 7 ...- n h. 1 . TL ., A 4 V ;
- iTL 10NL-'
b
? ..
yL } A/ k' { -l 7J% ,\Y~9TL-32 TL-0K y ;; 1
'-( ~ - w ~m 4 - / \. ; \l> \ x,/ d' %lt 1
4 ~-< y' 1 x
==
21
% ,f \< -~, ~%., f \,f _j,q ,, .
7x_,,yr - l h, /, ~/ 5 / -
\* ' ,.a j f/
v' - Salisbury s A !
'm -'-Q v 4x9 k / , 7' f
1 ml {'Z - y' j->
' ' - - ~ ~ ~
pr.e.an usoping cw issue w son. ors m, parim copynont 1se2.tsee mus.ine. FIGURE 2.4 Direct Radiation Monitoring Locations Within 4 Kilometers of Seabrook Station
~
71 or as . 43 0r w I CX s r ,
, l } \ l #~ _v / /
1 01 f Portsmouth r A
'
- L-1 TL-30
\ ime , A 'K~ 7x N ~~ _, . TL-18 i I
TL-1 A TL i , 8 TL-28 TL-29 TL-31 _-._ / Kings {on TL 7
'- / TL-27 ,,- ,
sf
/ 6 \ sali / **T Ni TL-2 -*' N ; / TL.23 ^ TL-23 Haverhill /
L-33
- / , ~/ / y
(- , i - 1 5 ml / FIGURE 2.5 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS BETWEEN 4 KILOMETERS AND 12 KILOMETERS FROM SEABROOK STATION
7121r 1S*. 4317' 39' l ' ( 1 2e ! Direct Radiation % ( Monitoring Locatio9s \
' )
Outside 12 Kilometers F{-i s
, A \ 1oic l
Manchester Fremont
'f l
( si
}~ ~ '
- s
/ , /- + '
c :
/ h,_,7%.3 u / < ! \
l / \ I(l CD
\ ,5F
( .. .) . /,f~_s / _ (
/ /
u [ j l, -lf
/R\ ' '1 mie '
l useens cappve 1ses.se, Just ScRaerke he, Pornww CoprWW 1s02-1s08 MUS,len FIGURE 2.6 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS OUTSIDE 12 KILOMETERS OF SEABROOK STATION J
3.0 Summary of Radiological Environmental Data The following pages summarize the analytical results of the environmental samples, which were collected in 1998. Each environmental media category is presented as a separate subsection. A table that summarizes the data follows a discussion of the mampling requirements and results for each program. Listed at the top of each table are the units of measurement for each medium. The left-hand column contains the radionuclide, which is being reported, total number of analyses of that radionuclide, and the number of measurements that exceed ten times the yearly average of control measurements. The latter are classified as "non- routine" measurements. The next column lists the Lower Limit of Detection (LLD) for those radionuclides which have detection capability requirements specified in the Off-Site Dose calculation Manual. Those sangling stations which are adjacent to the plant and which could conceivably be affected by the operation of Seabrook Station are called
" Indicator" or " Zone 1" stations. Distant stations, which are beyond plant influences, are called " Control" or " Zone 2" stations. Direct radiation (TLD) monitoring locations are subdivided into site boundary, inner ring, and outer ring (emergency response) stations.
A set of statistical parameters is calculated for each radionuclide. This set of statistical parameters includes separate analyses for (1) the indicator stations, (2) the station having the highest annual mean concentration for that radionuclide, (3) and control stations. For each of these three groups of data, these parameters are as follows: The mean value of all concentrations.
- The range of values.
The number of positive measurements (a concentration which is greater than the a posteriori LLD for that analysis) divided by the total number of measurements. Each single radioactivity measurement datum in this report is based on a single measurement and is reported as a concentration plus or minus a one standard deviation uncertainty. The quoted uncertainty term represents only the random uncertainty associated with the radioactive decay process (counting statistics), and not the propagation of all possible uncertainties in the analytical procedure. Attachment I contains the data for the samples collected in 1998. The results are organized by sample type, within each sample type listing the data is alphabetical by nuclide, within each nuclide listing the data is chronologically arranged by end date (date of sample collection). The radionuclide value concentrations (charcoal media) have been corrected for radioactive decay to the end of the collection. The airborne radiolodine (charcoal) concentrations have been calculated assuming a constant flow rate and concentration throughout the collection period and correcting for decay while sampling as well as between sample collection termination and analysis. Pursuant to ODCM requirements, any concentration below the LLD for its analysis is reported as "not detected". These values are set to zero for averaging purposes. Where a range of values is reported in the tables of this section, values less than the a posteriori LLD for the analysis are reported as zero. 13 J
l A) Air Particulate Air monitoring stations were established at a total of eight locations (five are required by the Offsite Dose Calculation manual). Seven of I the locations are indicators, while the remaining one is a control station. Airborne particulates are collected by passing the air through a glass-fiber filter. These filters are collected weekly and held for at least 100 hours before being analyzed for gross-beta activity j (indicated as GR-B in tables) to allow for the decay of radon daughter 4 products. For the year, 415 particulate filters were collected for gross beta activity. A particulate filter from station #5 during week #10 was not sampled due to very low sample volume. This was due to an unintentional cut off of pcwer to the sampler. Quarterly composite air filters from each location were analyzed for gamma emitting radionuclides. In 1998, naturally occurring Be-7 was the j only nuclide detected. All gross beta samples were collected as 4 required. 1 I i i { i i 14
r i i l l FIGURE 3.1 l GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS i SEABROOK STATION I l I 0.08 -- 7 0.08 7 1 ! 0.07-i -0.07 ! J s u 0.06- -0.06 , 0 [ l y 0.05- r0.05 I E F y 0.04- -0.04 { o j 3 6 3
) 0.03J 6 -0.03 I ,
0- 1 - r -0 January April July October January I 1998 ll
-O- AP-01 Barge Landing Area l l i -o - AP-02 Hampton Marina ; ;
AP-03 SW Boundary
-o- AP-04 W Boundary , l l l ! -y- AP-05 Winnacunnet High School i -X-- AP-06 Georgetown Substation (Control! -+- AP-07 PSNH Substation, Hampton l ; -w- AP-08 Exeter & Hampton Electric Co.
15. i
c: I l FIGURE 3.1.1 GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS QUARTERLY AVERAGES SEABROOK STATION 0 .16 --- -- - -- - - - - - - - -
; 0.16 a Chernobyl h' O.14 j May, 1986 '[ 0.14 ,l 'r.
l 0.12 1 5% Criticality [0.12 j ! June, 1989 f y 0.1 --j , F 0.1 y ; 1 n O i i h a 4 l t h _l ! Full Power [0.OS
) j ! lMay, 1990 [
Q _ 0 . 0 6 -j l j 0.06 J i i ;
.) : I 4 i
0.04 4 F0.04 4 y O.02- 5gkb $ g $$ 9 g g8 g g@g@8 0.02 l ! h 0--' .
, '- r .
r- -- r -- - , - L 0 i j 1985 1987 1989 1991 1993 1995 1997 1999 1 I
- AP-01 Barge Landing Area j l !
f -o- AP-02 Hampton Marina l 1
--n-- AP-03 SW Boundary !
i ! !
} ,
j l " X-- AP-06 Georgetown Substation (Control) j [- L._ _ _ . _ _ . __._J l-I 16.
F T FIGURE 3.1.2. GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS
-QUARTERLY AVERAGES 3 SEABROOK STATION 0.16 r--- - . 0.16 t
O.14- 0*14 Chernobyl p iMay, 1986 r 0.12 j 4 l b0.12
) s 5% Criticality. I y 0.1,] June, 1989 .a ,
0.1 f *
; Full Power * ) ] lMay, 1990 [
Q -0.06-l [-0.06 i y [ 0.04- ' O.04 l-t 0.02-b g g g m QQ g/g gg ggg gn -0.02
'l I t-0 --f-- -r I -- 0 3---- ,
i -i - - , , 1985 1987 1989 1991. 1993- 1995 1997 1999 l l-I -O- . AP-04. W Boundary - t { --o- AP-05 Winnacunnet High School
- - x- AP-06 Georgetown Substation (Control) l I
i
- 17. I
i e FIGURE 3.1.3 . GROSS-BETA MEASUREMENTS OF AIR PARTICULATE FILTERS
-QUARTERLY AVERAGES SEABROOK STATION 0.16' r.a .-0.16 p
I t-
?0.14- Chernobyl io,14 j May, 1986 _
j 0.12- 1 0.12 I 5% Criticality f i 0.1 i . June, 1989 .g. a i h-0.1 (
!! I i g 0.08- j U
Full Power. h 'l N 1- f May, 1990 r 1 D 0.06] l':- I-0.06 a p 1, $ -
~
0.04 h0.04 l X . XX 0.02 A EX%j* \ X N g 66 -0.02 l 0l~t- c d- i e
? ' ,
a 7 i -+- 0 1985 1987 1989- 1991 1993 1995 1997 1999 l -O- 'AP-07 PSNH Substation, Hampton j
'I .! ,= - o- AP-08 Exeter & Hampton Electric Co. -x- AP-06 Georgetown Substation (Control) j 18.
t 1 i FIGURE 3.2 GROSS-BETA ON AIR PARTICULATE FILTERS i QUARTERLY AVERAGES SEABROOK STATION 0.08 , ----- - - --- - - - - - -
; 0.08 i 1 i
J L
'O.06- s0.06 u i D i " t E i d 0. 04 -i L- 0. 04 0 !
N I U i a i ( 0.02 ,gv \ d SV R g " % g/ ~ ~ o7 r ,-- - j-0 r- ; --7 1/1/94 1/1/95 1/1/96 1/1/97 1/1/98 1/1/99
~O- Indicators l l !
j Control
-X- j ! -_. _ _o :
1 r 1 i l 19. i
)
i
r j I l { 1 Radiological Environmental Program Summary j i Seabrook Nuclear Power Station, Seabrook, NH (January December 1998) i MEDIUM: Air Particulates (AP) UNITS: pCl/ cubic meter Indicator Stations Station Wdh Hghest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected **) (No. Detected **) (No. Detected") l GR-B (415) 0.01 1.8E -2 03 2.0E -2 1.9E -2 (0) ( 5.3 - 40.5)E -3 ( 6.0 - 38.1) E - 4 ( 6.1 - 36.0)E -3 (363/ 363) (52/ 52) (52/ 52) Be.7 (32) 8.9E -2 03 1.0E -1 8.7E -2 (0) ( 4.6 - 15.1)E -2 ( 6.6 - 15.11E -2 < 7.7 - 9.7)E -2 (28/ 28) (4/ 4) (4/ 4) K40 (32) -2.7E -4 08 3.8E -3 -6.1E -4 (0) ( -7. 9 - 7. 5) E -3 ( 1.1 - 6.0)E -3 ( -5.1 - 1.7)E -3 (0/ 28) (0/ 4) (0/ 4) Cr.51 (32) -9.4E -4 06 5.6E -3 5.6E -3 (0) ( -2.3 - 2.0)E -2 ( -2.8 - 10.1)E -3 ( -2.8 - 10.i>E -3 (0/ 28) (0/ 4) (0/ 4) Mn-54 (32) 4.2E -5 04 2.0E -4 -1.3E -4 (0) ( -3.2 - 8.2)E -4 ( -1.6 - 8.2)E -4 ( -5.8 - 1.5)E -4 .j (0/ 28) (0/ 4) (0/ 4) l i Co-57 (32) 4.4E -5 08 1.4E -4 -5.3E -5 (0) ( -1.7 - 3.5)E -4 ( 3.5 - 26.7)E -5 ( -1.1 - 0.1)E -4 (0/ 28) (0/ 4) (0/ 4) ; 1 Co-88 (32) 5.5E -5 04 4.4E -4 -1.5E -4 l (0) ( -6.1 - 9.1)E -4 ( -2.2 - 8.0)E -4 ( -6.2 - 3.6)E -4 (0/ 28) (0/ 4) (0/ 4) Fe-59 (32) -1.5E -4 08 1.0E -3 -4.0E -4 (0) ( -2.7 - 4.0) E -3 ( -1.0 - 4.0)E -3 ( -1.4 - 1.2)E -3 (0/ 28) (0/ 4) (0/ 4) Co-60 (32) 3.2E -5 08 3.0E -4 -9.6E -5 s (0) ( -7.8 - 7.9)E -4 ( 1.7 - 5.6)E -4 ( -3.5 - 1.3)E -4 (0/ 28) (0/ 4) (0/ 4) Zn45 (32) -2.1E -4 .?4 5.4E -4 -3.3E -5 (0) ( -2.1 - 2.2)E -3 ( -4. 2 - 21. 9) E -4 ( -6.8 - 4.9)E -4 (0/ 28) (0/ 4) (0/ 4) Se 75 (32) 1.2E -4 03 3.8E -4 -9.4E -5 (0) ( -1.1 - 0.7)E -3 ( 0.0 - 6.0)E -4 ( -3. 4 - 1.7) E -4 (0/ 28) (0/ 4) (0/ 4) Zr-95 (32) 1.0E -4 06 5.0E -4 5.0E -4 (0) ( -1. 4 - 1. 4) E -3 ( 1.3 - 7.1)E -4 ( 1.3 - 7.1)E -4 (0/ 28) (0/ 4) (0/ 4)
r Radiological Environmental Program Summary [ Seabrook Nuclear Power Station, Seabrook, NH (January December 1998) MEDIUM: Air Particulates (AP) UNITS: DCl/ cubic mg
$.d,i,c,a,t,g[,S,t,aygns,,, Station ,,, ,,, ,g,g, ,y,H gest y,ean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analysea) Required Range Range Range f
(Non-Routine *) LLD (No. Detected") (No. Detected **) (No. Detected **) Ru-103 (32) -7.4E -5 05 3.6E -4 -2.6E -4 (0) ( -1.6 - 1.6)E -3 ( -4.1 - 16.1)E -4 ( -1.0 - 0.1)E ~3 (0/ 28) (0/ 4) (0/ 4) Ru 106 (32) 1.5E 4 07 2.1E -3 -2.0E -4 (0) ( -6.3 - 6.2)E -3 ( 0.0 - 40880.0)E -7 ( -3.0 - 4.5)E -3 (0/ 28) (0/ 4) (0/ 4)
]
Ag 110M (32) -4.5E -5 03 1.3E -4 -4.1E -5 (0) ( -6.7 - 5.4)E -4 ( -5.3 - 5.3)E -4 ( -6.5 - 3.3)E -4 l (3/ 28) (0/ 4) (0/ 4) l Sb-124 (32) 2.0E -4 01 1.9E -3 -2.5E -4 (0) ( -2.7 - 4.0)E -3 ( 0.0 - 3.5)E -3 ( -7.7 - 2.5)E -4 (0/ 28) (0/ 4) (0/ 4) 1131 (32) 7.4E -3 07 8.2E -2 -2.0E -3 (0) ( -1. 8 - 3. 2) E ~1 ( -5.8 - 315.3)E -3 ( -1.3 - 0.3)E -2 (0/ 28) (0/ 4) (0/ 4) Cs-134 (32) 0.05 -6.9E -5 07 6.9E -5 -2.2E -4 (0) ( -6.2 - 6. 9) E -4 ( -3.1 - 4.1)E -4 ( -5. 4 - 0.3)E -4 (0/ 28) (0/ 4) (0/ 4) Cs.137 . (32) 0.06 -8.4E -5 04 4.0E -5 0.0E O (0) ( -6.8 - 4.9)E -4 ( -3.6 - 4.9)E -4 ( -9.7 - 9.6)E -5 (0/ 28) (0/ 4) (0/ 4) 8a 140 (32) -1.1E -3 05 4.8E -3 -1.5E -3 (0) ( -3.4 - 1.4)E -2 ( -5.2 - 13.9)E -3 ( -9.8 - 15.9)E -3 (0/ 28) (0/ 4) (0/ 4) Co 141 (32) -1.9E -4 01 6.5E -4 -2.0E -4 (0) ( -2.7 - 2.4)E -3 ( -1.8 - 2.4)E -3 ( -1.3 - 1.9)E -3 (0/ 28) (0/ 4) (0/ 4) Co-144 (32) 2.2E -4 08 9.7E -4 -3.2E -4 (0) ( -1.5 - 3.0)E -3 ( 7.1 - 299.0)E -5 ( -2.2 - 1.0)E -3 (0/ 28) (0/ 4) (0/ 4) Th-232 (32) -3.1E -4 06 1.1E -3 1.1E -3 (0) ( -1. 9 - 2.1) E -3 ( -7. 0 - 27. 6) E -4 ( -7.0 - 27.6)E -4 l (0/ 28) (0/ 4) (0/ 4) {
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
l
** The fraction of sample analyses yielding detectable measurements (i e. >3 standard deviations) is shown in parentheses.
l 1 1 4
B) Charcoal Filters charcoal filter cartridges are in series with the air particulate glass-fiber filters. Monitoring stations were established at a total of eight locations (five are required by the ODCM). Seven of these are l indicators and one is a control. Charcoal filters from the air sampling l stations were collected and analyzed weekly for I-131 activity. During 1998, A total of 414 charcoal cartridges from all eight locations were analyzed. For the year, 415 particulate filters were collected for gross beta activity. A particuli.te filter from station #5 during week
#10 was not sampled due to very low sample volume. This was due to an unintentional cut off of power to the sampler. A charcoal filter cartridge for sampler #8 was inadvertently not replaced for sample week #35. No I-131 activity was detected.
22
p l l l [ Radiological Environmental Program Summary I' Seabrook Nuclear Power Station, Seabrook, NH (January December 1998) MEDIUM: Charcoal Cartridos (CF) UNITS: DCl/ cubic motor
'".d,g,g{,S,t,agon,s,,,
Station
,,,,,,, ,gtg,y,iggg,st y,ean,, Control Statior,9,,,,
Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range. Range (Non-Routine *) LLD (No Detected") (No. Detected") (No. Detected") 1 1-131 (414) 'O.07 4.0E -4 04 2.5E -3 -1.4E -3 (0) ( -3.1 - 2.5)E -2 ( -2.5 - 2.5)E -2 ( -3.0 - 2.2)E -2 j (0/ 362) (0/ 52) (0/ 52) j 1
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3. l l
** The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations)is shown in parentheses.
l I I
e 1 l l . l j C) Milk Milk samples were collected every two weeks during the pasture season i and monthly at other times. Samples are analyzed for I-131 and l gamma-emitting radionuclides. , 1 Detectable concentrations of Cs-137 were measured in several samples collected in 1998. Five positive results for Cs-137 were detected at required locations TM-04 (3), TM-09 (1), and TM-15 (1). Additional locations TM-16 (8) and TM-21 (1) also had positive Cs-137 results. It has been shown in the preoperational program that this nuclide is the result of atmospheric nuclear weapons testing that persists in the environment. The levels of Cs-137 detected in 1998 are consistent with that detected in the. pre-operational phase. l l Potassium-40 is a naturally occurring nuclide detected in the milk samples. 24
7 - .- l 1 l l s l l i FIGURE 3.3 CESIUM-137 IN MILK 3 SEABROOK STATION 30 -- - - - - - - - - - - - - - - - - - - - - - - - --
-- - 30 i , L- i e
25 ! 4 f-25 i l 20-1 -20 p 15 , [- 15 s .-
.a ,
a O a 10 ' ; 10 l A , z 5 --i A As oN N x ja / 8s - e ns ,M - L5
- . As a <3 - ,- >o _. v. o ,.
0;M '" sq < s So. O ,- k f> / 5 "u A a.'o92=-8b 0
^0k s ~
0 o ' I- 0 0 ,
, - -- : - . -- 7--i-5 I Dec Feb Apr Jun Aug Oct Dec Feb ;
1 1998 I r --- - - - - - - - - - - - ----- - -- - - - -- - -
-l ; -O- TM-04 Dairy Farm, Salisbury MA '
i l -- o - TM-08 Dairy Farm, Hampton Falls NH 1 l
-o- TM-09 Dairy Farm, Hampton NH i -a- TM-15 Goat Herd, Hampton Falls NH ,
I f
-E- TM-04 Positive Concentration l fi - ,-- TM-09 Positive Concentration g-- TM-15 Positive Concentration i L ,
i l 25. \ l
FIGURE 3.3.1 CESIUM-137 IN MILK ANNUAL AVERAGE CONCENTRATIONS 50 , -- --
, 50 . t t
4 e 40-. Chernobyl b40
- May, 1986 [
1 - 1 ! r 30 1 i 5% Criticality : g i June, 1989 r 30 l L N, l S 20 Ii I I i Full Power 20 1 ! ' lMay, 1990 F 4 4 J ' i i L 10- O'~O s' '- 10 l , . 6- A@ 9 f= 0 ~~,-Qa s e 49Qo phin:==h%g::5p;p-gyg F 0 7--- r - - , - - > -~ r = ,-- m -
-0 1985 1987 1989 1991 1993 1995 1997 1999 l -- O - TM-04 Dairy Farm, Salisbury MA ;
i l I o- TM-08 (prior to 1995 TM-10) Diary Farm, Hampton Falls NH l -o-- TM-09 Dairy Farm, Hampton NH i -A- TM-15 Goat Herd, Hampton Fall.s NH L.._..._._-_.._..__..._ _ . . . _ . . . _ _ _ . _ _ _ . _ _ _ _ ._ . . . _ _ . . . . _ . _ . . _ . _ _ . . _ _ . 26.
l FIGURE 3.4 CESIUM 137 IN MILK , SEABROOK STATION 3 0 -- ----- -- -- - - - - ~ - - - - - - - - _ . . - _ 30 25{ -7 25 20-f-- 20 3 s 15 -{ u
-15 dc. -
m 8'8 m s' : 10 - -10
- m :
O A 's - 5- O -5 o / o - 8-c'a O Da 6 og8$ 3_ o-Opg<a-$' 0 o-og- o-o ~'O Ag a-a { 0- a o ~~.. go g' 70 a o 1
-5 ~ --- - - - - - -5 !
Dec Feb Apr Jun Aug Oct Dec Feb 1998
--O -- TM-16 Goat Herd, Kensington UH ! -o - TM-20 Dairy Farm, Rowley IG (Centrol) i -n- TM-21 Dairy Farm, N Andover IG (Control) I l -u- TM-16 Positive Concentrations A- TM-21 Positvie Concentrations a
l l
- 27. !
1 J
F i I l I l l I FIGURE 3.4.1 I CESIUM-137 IN MILK ANNUAL AVERAGE CONCENTRATIONS 50 ; - --- - ---- 7r 50 4 1 L l Chernobyl l-40j May, 1986 L j 5% Criticality ll40 June, 1989 , l e 1 30 , F 30
, j l x i ) ] ; jFull Power [
Q l } 'May, 1990 ! 20H l L20 1 ! l 1 ! , l D ! 10-))
,/ { I7 10 04 ri~f'_ :
g =_=]EQ- j-i r T- - -r0 1985 1987 1989 1991 1993 1995 1997 1999 l l
-O- TM-16 Goat Herd, Kensington NH i - O - -- TM-20 Dairy Farm, Rowley MA (Control) i i -a- TM-21 Dairy Farm, N. Andover MA (Control) l L _ _ _
28.
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January . December 1996) l MEDIUM: Milk (TM) UNITS: OCl/kg indicator Stations Station With Hghest Mean Control Stations I Radionuchdes Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected **) (No. Detacted") Be-7 (126) -6.1E -1 09 3.1E O 2.4E 0 (0) ( -2.7 - 3.1)E 1 ( -1.7 - 3.1)E 1 ( -2.1 - 2. 6) E 1 (0/ 90) (0/ 18) (0/ 36) K-40 (126) 1.6E 3 16 1.8E 3 1.4E 3 (0) ( 1.1 - 2.0)E 3 ( 1.7 - 2.0)E 3 ( 1.1 - 1.5)E 3 (90/ 90) (18/ 18) (36/ 36) Cr-51 (126) 7.8E -1 04 3.3E 0 -8.9E -1 (0) ( -3. 9 - 4. 9)E 1 ( -3.9 - 4.9)E 1 ( -3.2 - 2.5)E 1 l (0/ 90) (0/ 18) (0/ 36) Mn-54 (126) -2.3E -2 09 3.5E -1 7.1E -2 (0) ( -4.2 - 4.1)E O ( -2.1 - 2.9)E O ( -2.4 - 2.9)E 0 (0/ 90) (0/ 18) (0/ 36) , I Co-57 (126) -1.0E -1 16 2.2E -1 -6.8E -2 i (0) ( -3.2 - 2.5)E O ( -2.1 - 2.5)E 0 ( -1.9 - 1.4)E O ( l (0/ 90) (0/ 18) (0/ 36) ' Co-56 (126) 1.6E -2 16 3.6E -1 -2.1E -1 l (0) ( -4.2 - 4.3)E O ( -2.5 - 4.3)E O ( -4.6 - 2.6)E O j (0/ 90) (0/ 18) (0/ 36) Fe-59 (126) 1.7E -1 21 1.3E O 9.6E -1 (0) ( -1.2 - 1.5)E 1 ( -5.7 - 8. 9)E O ( -7.0 - 8,9)E O (0/ 90) (0/ 18) (0/ 36) Co-60 (126) 2.2E -1 08 6.2E -1 -3.1E -2 ; (0) ( -3.6 - 5.5)E O ( -2.1 - 2.5)E O ( -2.7 - 2.4)E O j (0/ 90) (0/ 18) (0/ 36) Zn-65 (126) -4.2E -1 04 2.6E -1 -6.6E -1 j (0) ( -1.2 - 1.8)E 1 ( -1.2 - 1.1)E 1 ( -1.2 - 0.8)E 1 (0/ 90) (0/ 18) (0/ 36) Se-75 (126) -1.1E -1 15 7.4E -1 1.6E -1 (0) ( -6.0 - 3.7)F 0 ( -1.6 - 3.7)E 0 ( ~4.1 - 3.7)E D (0/ 90) (0/ 18) (0/ 36) Zr.95 (126) 2.1E -1 04 1.1E O -1.5E -1 (0) ( -5.6 - 7.9)E C ( -1.5 - 3.0)E 0 ( -6.2 - 7.3)E O (0/ 90) (0/ 18) (0/ 36) Ru-103 (126) -9.9E -1 15 -7,5E -1 -9.0E -1 (0) ( -3.8 - 2.3)E 0 ( -3.2 - 1.7)E O ( -5.9 - 2.6)E O (0/ 90) (0/ 18) (0/ 36)
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook NH (Januery December 1996) MEDIUM: Milk (TM) UNITS: pCilka
'ad.'c*t3 . . sja,t!ons,, s on,yy, ,,g,, hHjhest yp,an ,,, , go,n,ty,o,1,S, tag,ons,,,,
Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) ~LLD (No. Detected") (No. Detected **) (No. Detected") l Ru 106 (126) 8.7E -1 06 3.0E 0 -1.3E o (0) ( -3.2 - 3.1)E 1 ( -1.9 - 3.1)E 1 ( -1.9 - 3.2)E 1 (0/ 90) (0/ 18) (0/ 36) Ag.110M (126) 4.0E -2 16 5.4E -1 2.1E -1 (0) ( -4.1 - 4.7)E o ( -2,4 - 4.7) E O ( -2.1 - 8.0)E O (0/ 90) (0/ 18) (0/ 36) Sb-124 (126) 1.7E -1 16 9.3E -1 -4.6E -1 (0) ( -7. 5 - 10. 0) E 0 ( -5.3 - 9.4)E 0 ( -5.4 - 5.4)t 0 (0/ 90) (0/ 18) (0/ 36) 1-131 (126) 1 2.5E -2 09 3.3E -2 1.8E -2 (0) ( -1.0 - 3.5)E -1 ( -1.0 - 3.5)E -1 ( -5.8 - 17.0)E -2 (0/ 90) (0/ 18) (0/ 36) l l Cs.134 (126) 15 3.2E -2 16 3.3E -1 -2.7E -1 i (0) ( -4.7 - 3.2;E o ( -1.9 - 2.8)E O ( -3.4 - 2.7)E O I (0/ 90) (0/ 18) (0/ 36) Cs 137 (126) 18 3.4E O 16 7.2E O 1.6E O (0) ( -1.6 - 13.6)E O ( 1.6 - 13.6)E O ( -2. 9 - 6.5)E O (13/ 90) (8/ 18) (1/ 36) Ba 140 - (126) 15 2.4E -1 16 1.1E 0 -2.2E -1 (0) ( -4.0 - 5.6)E O ( -2.2 - 4.5)E O ( -6.8 - 4.3)E O (0/ 90) (0/ 18) (0/ 36) Co-141 (126) -1.6E -1 16 6.6E -1 -1.2E 0 (0) ( -6.6 - 5.9)E o ( -4.3 - 5.9)E 0 ( -5.1 - 1.5)E O (0/ 90) (0/ 18) (0/ 36) Co-144 (126) 3.5E -1 06 3.1E O -8.8E -1 (0) ( -2.8 - 2.1)E 1 ( -1.6 - 2.1)E 1 ( -2. 6 - 1.4)E 1 (0/ 90) (0/ 18) (0/ 36) Th-232 (126) 9.6E -1 09 2.0E O -6.9E -1 (0) ( -1.4 - 1.5)E 1 ( -1.4 - 1.3)E 1 ( -1. 2 - 1. 2 ) E 1 (0/ 90) (0/ 18) (0/ 36)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
" The fraction of sample analyses yielding detectable measurements (i e. >3 standard deviations) is shown in parentheses.
D) Surface Water Surface water (seawater) grab samples are required at two locations monthly. A gamma analysis is performed on each sample. A tritium analysis ~is performed on the quarterly composite of these samples. The only radionuclide detected in 1998 was naturally occurring K-40. l l s 31
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January December 1998) MEDIUM: Sea Water (WS) UNITS: pCl/ka Injgtgg,t,gs,,
. ,,Statp,n,With Hghest Mean, Control Stations ,
Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine") LLD (No. Detected") (No. Detected") (No. Detected **) H-3 (8) 3000 1.0E 2 01 1.0E 2 -6.0E i (0) ( -2.0 - 4.6)E 2 ( -2.0 - 4.6)E 2 ( -4.4 - 0.8)E 2 (0/ 4) (0/ 4) (0/ 4) Be-7 (24) 1.4E 0' 01 1.4E O -3.1E o (0) ( -1.1 - 1.5)E 1 ( -1.1 - 1.5)E 1 ( -1.9 - 0.7)E 1 ) (0/ 12) (0/ 12) (0; 12) K-40 (24) 2.9E 2 01 2.9E 2 2.7E 2 (0) ( 2.4 - 3.4)E 2 ( 2.4 - 3.4)E 2 ( 1.6 - 3.4)E 2 l (12/ 12) (12/ 12) (12/ 12) ' Cr-51 (24) -6.2E O 51 3.1E O 3.1E 0 (0) ( -2.3 - 1.3)E 1 ( -4.4 - 13.2)E 0 ( -4.4 - 13.2)E O (0/ 12) (0/ 12) (0/ 12) ) Mn-54 (24) 15 -4,7E -1 51 -9.1E -2 -9.1E -2 I (0) ( -2.8 - 1.0)E 0 ( -1.3 - 1.4)E O ( -1.3 - 1.4)E O l (0/ 12) (0/ 12) (0/ 12) Co-57 (24) 3.5E -2 51 9.6E -2 9.6E -2 (0) ( -1.0 - 1.1)E O ( -1. 2 - 1. 7 ) E 0 ( -1.2 - 1.7)E O (0/ 12) (0/ 12) (0/ 12) Co-56 (24) 15 -2.OE -2 51 2.6E -1 2.6E -1 (0) ( -1. 0 - 2. 6) E O ( -1.7 - 1.7)E 0 ( -1.7 - 1.7)E 0 (0/ 12) (0/ 12) (0/ 12) Fe-59 (24) 30 -5.BE -1 51 5.6E -1 5.6E -1 (0) ( -6.7 - 3.8)E O ( -5.6 - 5.2)E 0 ( -5.6 - 5.2)E 0 (0/ 12) (0/ 12) (0/ 12) Co-60 (24) 15 5.2E -2 01 5.2E -2 4.4E -2 (0) ( -2.6 - 3.1)E O ( -2.6 - 3.1)E 0 ( -2.4 - 1.9)E 0 (0/ 12) (0/ 12) (0/ 12) l l l Zn-65 (24) 30 5.8E -1 01 5.8E -1 4.4E -1 l l (0) ( -8.9 - 6.0)E O ( -8.9 - 6.0)E D ( -3.2 - 6.9)E 0 (0/ 12) (0/ 12) (0/ 12) I So-75 (24) 2.3E -1 01 2.3E -1 2.1E -1 (0) ( -3.0 - 3.9)E O ( -3.0 - 3.9)E O ( -2.0 - 3.1)E 0 (0/ 12) (0/ 12) (0/ 12) Zr-95 (24) 15 2.3E -1 01 2.3E -1 8.8E -2 (0) ( -2.4 - 2.8)E o ( -2.4 - 2.8)E 0 ( -1.9 - 2.2)E O (0/ 12) (0/ 12) (0/ 12) i
p l I l I Radiological Environmental Program Summary i ! Se6 brook Nuclear Power Station, Seabrook, NH t l (January . December 1998) i MEDIUM: See Water (WS) UNITS: pCl/ka I , l Station....h..Hghest Wit l Ind.i.c.a.t.or.Sta.t.io..n.s
... . ......... . Mea n . . - . . . . . . . . . . C. ontrol Stations l l
Radionuctedes Mean Sta. Mean Mean I (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected **) (No. Detected **) (No. Detected") l Ru 103 (24) -5.9E -1 01 -5.9E -1 -1,2E O (0) ( -2,3 - 2.4)E O ( -2.3 - 2.4)E o ( -2.8 - 2.2)E o (0/ 12) (0/ 12) (0/ 12) Ru-106 (24) 1.3E o 01 1.3E O 1.3E -2 (0) ( -2.3 - 1.5)E 1 ( -2.3 - 1.5)E 1 ( -6.8 - 16.2)E o (0/ 12) (c/ 12) (0/ 12) l Ag-110M (24) -8.3E -2 51 5.5E -1 5.5E -1 (0) ( -2.4 - 4.3)E o ( -1.8 - 3.6)E o ( -1.8 - 3.6)E o I (0/ 12) (0/ 12) (0/ 12) Sb-124 (24) 9.2E -1 01 9.2E -1 -1.5E -1 (0) ( -3.9 - 5.6)E 0 ( -3.9 - 5.6)E o ( -6.9 - 6.4)E O (0/ 12) (0/ 12) (0/ 12) , I l-131 (24) 15 4.8E -1 01 4.8E -1 -2.4E -1 ; (0) ( -3.0 - 3.6)E o ( -3.0 - 3.6)E o ( -4.3 - 3. 6)E o j (0/ 12) (0/ 12) (0/ 12) Cs-134 (24) 15 -6.4E -2 01 -6.4E -2 -2.9E -1 (0) ( -1.7 - 2.0)E O ( -1.7 - 2.0)E O ( -5.2 - 1.3)E o (0/ 12) (0/ 12) (0/ 12) Cs 137 (24) 18 -2.7E -1 61 -1.3E -1 -1.3E -1 (0) ( -1.8 - 1.5)E O ( -2.5 - 0.7)E o ( -2.5 - 0.7)E O (0/ 12) (0/ 12) (0/ 12) Ba-140 (24) 15 9.4E -2 01 9.4E -2 -1.0E 0 (0) ( -3.0 - 5.6)E o ( -3.0 - 5.6)E O ( -4.1 - 1.0)E 0 (0/ 12) (0/ 12) (0/ 12) Co-141 (24) -1,6E O $1 -1.1E O -1.1E 0 (0) ( -3.9 - 2.7)E O ( -4.8 - 0.7)E 0 ( -4.8 - 0.7)E 0 (0/ 12) (0/ 12) (0/ 12) Co-144 (24) 9.9E -2 51 2.5E O 2.5E O (0) ( -1.0 - 0.7)E 1 ( -7.6 - 12,0)E 0 ( -7.6 - 12.0)E 0 (0/ 12) (0/ 12) (0/ 12) Th-232 (24) 1.2E o 01 1.2E O 8.3E -1 (0) ( -5. 8 - 11. 6) E O ( -5.8 - 11.6)E O ( -3.9 - 11.2)E O , (0/ 12) (0/ 12) (0/ 12)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
** The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
E) Ground Wstar There is no requirement to collect ground water samples. Ground Water samples are obtained from two locations on a quarterly basis, and are ; analyzed for gross-beta activity, gansna-emitters and tritium. Gross i beta activity was detected in all samples taken and is due to naturally occurring radium and its daughter products. l l l l 1
- j l
I i 34
FIGURE 3.5 GROSS-BETA MEASUREMENTS OF GROUND WATER SEABROOK STATION 1 2 0 , -- - - - - - - - - -
,20 11
[ ; 182 L 18 I 4 i ; 16d L 16
?
14- h 14 L
, 12- [ 12 x -
3 3 10 ' I 10
- o
" i 8;
q [8 6 J. o' l-i 0
- 0 ~._._.,
[U~ [6 j 4b / %.:'~~ a ?-4 o- --O' '~o [ 2 -- ;7 2 r l 0--, r- - > T r- r-- 10 ! Feb Apr Jun Aug Oct Dec Feb 1998 l l i i I~
-O- WG-01 Seabrook Town Wells -o- WG-13 Seabrook Station Well No. 13
FIGURE 3.5.1 l GROSS-BETA MEASUREMENTS OF GROUND WATER SEMI-ANNUAL AVERAGES i SEABROOK STATION : l l 40 r- - --- -- --- - - - - -
-40 4 :
I L j L
! i F
30 --]l 1 i F
-30 j Chernobyl _ - May 1986 tn .
x 1
; 5% Criticality r 20- June, 1989 -20 ha ]
l 1 ,i [ a - l ? Full Power 1 J l May, 1990 [ 10 f I a o L 10 1 ! / '( .
! I a z O , , a O ~O'O'O'O'O'O'O W D l 1 l O 04 r L r --, l -- ,-- ,- - i-- O ; 4 , i 7 1985 1987 1989 1991 1993 1995 1997 1999 WG-01 Seabrook Town Wells i --o- WG-13 Seabrook Station Well No. 13 ;
36.
{ Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January December 1998) MEDIUM: Ground Water (WG) UNITS: DCi/ka IY.'.ca,to,[,S,ta,gons,,
. , Stgtion gtg,y,93,st y,ean,, , , , , , , , ,,, pgntrol Stabony,, ,
Radionuclides Mean Ea. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected") (No. Detected") GR-8 (8) 4 4.2E O 01 4.7E o NO DATA (0) ( 2.8 - 5.9)E o ( 3.8 - 5.4)E O (8/ 8) (4/ 4) H-3 (8) 3000 -3.8E o 13 3.8E 1 NO DATA (0) ( -3.1 - 2. 6) E 2 ( -3:1 - 2.6)E 2 (0/ 8) (0/ 4) Be.7 (8) -6.7E O 13 -2.0E 0 NO DATA (0) ( -1.9 - 0.2)E 1 ( -4.0 - 1.7)E O (0/ 8) (0/ 4) K-40 (8) -4.2E 0 01 3.1E 0 NO DATA (0) ( -4.6 - 2.1)E 1 ( -2.2 - 2.1)E 1 (0/ 8) (0/ 4) Cr51 (8) -3.7E O 13 -3.2E -1 NO DATA (0) ( -1.7 - 0.7)E 1 ( -3.2 - 4,3)E O (0/ 8) (0/ 4) Mn-54 (8) 15 -4.9E -2 13 4.9E -1 NO DATA (0) ( -1.5 - 1.8)E o ( -1.7 - 17.5)E -1 (0/ 8) (0/ 4) Co-57 (8) 3.4E -1 01 3.5E -1 NO DATA (0) ( -5.0 - 9.2)E -1 ( -2.2 - 7.4)E -1 (0/ 8) (0/ 4) Co-58 (8) 15 1.5E -1 13 3.7E -1 NO DATA (0) ( -1.3 - 1.8)E 0 ( -7.4 - 17.6)E -1 (0/ 8) (0/ 4) Fe-59 (8) 30 -6.6E -1 01 -4.9E -2 NO DA'tA (0) ( -5.9 - 2.9)E O ( -5. 9 - 2. 9) E O l (0/ 8) (0/ 4) f Co-60 (8) 15 4.2E -1 13 9.6E -1 NO DATA (0) ( -1.4 - 1.8)E o ( 8.2 - 184.4)E -2 (0/ 8) (0/ 4) Zn-SS (8) 30 -3.3E -1 01 7.1E ~1 NO DATA (0) ( -4.5 - 2.4)E O ( -8.3 - 24.2)E -1 (0/ 8) (0/ 4) So-75 (8) -2.9E -1 01 8.8E -3 NO DATA (0) ( -1.7 - 0.7)E O ( -6.7 - 6.6)E -1 (0/ 8) (0/ 4) l
. __ i
i Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January . December 1998) MEDIUM: Ground Water (WG) UNITS: DCi/kg Station With Hghest Mean In.d.ic.a.t.or.S..ta.t.
... . ion.s . . . . . . . . . . . . . ----- ..... C..o..n. - trol Stations Radionuchdes Mean Sta. Mean Mean ,,T (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected **) (No. Detected") ' Zr.98 (8) 15 1.2E o 13 1.3E O NO DATA j (0) ( 4.0 - 24 9.1) E -2 ( 2.9 - 24.9)E -1 (0/ 8) (0/ 4) l Ru.103 (8) -1.2E o 13 -8.8E -1 NO DATA (0) ( -3.0 - 0.1)E O ( -9. 9 - -6. 9) E -1 (0/ 8) (0/ 4)
Ru.108 (8) 1.6E o 01 3.6E O NO DATA l (0) ( -9.7 - 10.2)E o ( -5.7 - 10.2)E O (0/ 8) (0/ 4) Ag-110M (8) -1.7E -1 13 -1.4E -1 NO DATA (0) ( -1.9 - 1.3)E 0 ( -6.7 - 3.8)E -1 (0/ 8) (0/ 4) Sb-124 (8) 6.9E -1 13 1.1E o NO DATA (0) ( -1.7 - 3.4)E o ( -1.1 - 3.4)E 0 (0/ 8) (0/ 4) 1131 (8) 15 -6.3E -2 01 1.1E O NO DATA (0) ( -3.8 - 3.0)E o ( -2.3 - 3.0)E o (0/ 8) (0/ 4) Cs.134 (8) 15 7.1E -2 13 3.3E -1 NO DATA (0) ( -1.4 - 1.2)E O ( -1.0 - 1.2)E O (0/ 8) (0/ 4) Cs 137 (8) 18 -4.3E -2 of 5.6E -1 NO DATA (0) ( -8. 9 - 11. 4) E -1 ( -4.2 - 11.4)E -1 (0/ 8) (0/ 4) 5 Ba 140 (8) 15 -7.4E -1 13 -1.5E -1 NO DATA (0) ( -2.0 - 2.5)E o ( -2.0 - 2.5)E O (0/ 8) (0/ 4) Co 141 (8) -6.6E -1 13 -4.1E -1 NO DATA (0) ( -3.6 - 3.1)E O ( -3.6 - 2.6)E O (0/ 8) (0/ 4) Co.144 (8) -2.4E -1 13 1.1E o NO DATA (0). ( -5.7 - 3.7)E o ( -1.6 - 2.6)E o (0/ 8) (0/ 4) Th 232 (8) -1.2E 0 01 -9.6E -1 NO DAT1. (0) ( -3.2 - 0.5)E O ( -3.2 - 0.5)E O (0/ 8) (0/ 4)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5 3.
** The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
F) Sediment Semiannual sediment sampling is required at one location, although a total of five locations, three indicator and two control are collected. Each sediment core was sectioned into 5-centimeter segments. A gansna analysis was performed on each section. The only radionuclides detected in 1998 were naturally occurring K-40, Th-232 and its natural daughters. i i i l 39
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 1998) MEDIUM: Sediment (SE) UNITS: pCilka Station With Highest M Ind.ic.a.t.or.S..
. . . . - . tat.e..ns . ...........................ean.... C.o..n.t.r.ol Stations .
l Radionuclides Mean Sta. Mean Mean (No. Analysen) Required Range Range Range (Non-Routine *) LLD (No. Detected **) (No. Detected") (No. Detected **) Be.7 (30) -1.4E 1 57 1.4E 2 1.8E 1 (0) ( -3.5-- 4.0)E 2- ( -1.2 - 33.9)E 1 ( -2.6 - 3.4)E 2 (0/ 18) (0/ 6) (0/ 12) K.40 (30) 1.5E 4 08 1.7E 4 1.3E 4 (0) ( 1.1 - 2.1)E 4 ( 1.1 - 2.1)E 4 ( 1.0 - 1. 6) E 4 (18/ 18) (6/ 6) (12/ 12) Cr.51 (30) -3.2E 1 57 7.1E 1 -6.6E 1 (0) ( -1.5 - 0.7)E 3 ( -2.4 - 4.5)E 2 ( -3.4 - 4.5)E 2 (0/ 18) (0/ 6) (0/ 12) Mn-54 (30) 7 0E 0 08 1.9E 1 -2.7E O (0) ( -2.7 - 4.1)E 1 ( -7.7 - 40.9)E O ( -2.3 - 2.2)E 1 (0/ 18) (0/ 6) (0/ 12) Co-57 (30) -2.3E O 07 1.9E 0 -3.1E o (0) ( -2.4 - 1.7)E 1 ( -2.1 - 1.4)E 1 ( -2.6 - 1.6)E 1 - (0/ 18) (0/ 6) (0/ 12) Co.58 (30) -3.0E O 02 3.8E -1 -7.2E O (0) ( -3.3 - 2.3)E 1 ( -1.8 - 1.8)E 1 ( -2.9 - 2.5)E 1 (0/ 18) (0/ 6) (0/ 12) Fe.59 (30) 4.2E 0 52 4.9E 1 2.1E 1 (0) ( -1.0 - 0.8)E 2 ( -4.8 - 12.9)E 1 ( -5. 5 - 12. 9) E 1 (0/ 18) (0/ 6) (0/ 12) Co.60 (30) 3.9E 0 02 1.2E 1 -3.2E o (0) ( -2.1 - 2.3)E 1 ( -4.3 - 23.5)E O ( -4.3 - 1.6)E 1 (0/ 18) (0/ 6) (0/ 12) Zn.65 (30) -1.1E 1 02 1.9E 1 -5.6E 0 (0) ( -7.6 - 6.7)E 1 ( -6.4 - 6.7)E 1 ( -1.1 - 1.1)E 2 (0/ 18) (0/ 6) (0/ 12) Se.75 (30) -9.9E O 57 1.8E -1 -4,1E O (0) ( -4.9 - 2.1)E 1 ( -1.8 - 1.3)E 1 ( -5.4 - 1.7)E 1 (0/ 18) (0/ 6) (0/ 12) Zr.95 (30) 3.5E 1 02 6.6E 1 2.1E 1 l (0) ( -5.0 - 15.0)E 1 ( -3.3 - 15.0)E 1 ( -6.7 - 9.1)E 1 (0/ 18) (0/ 6) (0/ 12) Ru.103 (30) -5.2E O 07 3.0E O -2.4E 0 (0) ( -6.5 - 3.9)E 1 ( -2.5 - 3.9)E 1 ( -1.9 - 4.8)E 1 (0/ 18) (0/ 6) (0/ 12)
Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January - December 1998) MEDIUM: Sediment (SE) UNITS: oCl/kn Ind,g,S,ta,tjo,,ns,,
. , Stabon q,Hp,p,st yean , ,,, , , , C,g,n, trol Stations ,
Radionucitdes Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected") (No. Detected") Ru-106 (30) -1.6E o 02 4.9E 1 -1.9E 1 (0) ( -3.2 - 3.8)E 2 ( -3.2 - 3.8)E 2 ( -3.1 - 3.2)E 2 (0/ 18) (0/ 6) (0/ 12) Ag.110M (30) 1.5E 0 08 5.7E 0 -8.4E -2 (0) ( -3.0 - 3.6)E 1 ( -1.9 - 3.6)E 1 ( -2.7 - 5.4)E 1 (0/ 18) (0/ 6) (0/ 12) Sb-124 (30) 1.0E 1 07 2.1E 1 -1.2E 1 (0) ( -4.0 - 5.6)E 1 .( -1.8 - 5.6)E 1 ( -3.4 - 3.0)E 1 (0/ 18) (0/ 6) (0/ 12) 1-131 (30) 3.9E 1 07 1.1E 2 -2.2E 1 (0) ( -2.2 - 2.0)E 2 ( 1.5 - 28.3)E 1 ( -1.4 - 2.1)E 2 (0/ 18) (0/ 6) (0/ 12) Cs 134 (30) 150 6.3E o 07 9.3E 0 -5.4E O (0) ( -2.1 - 3.2)E 1 ( -6.3 - 32.5) E O ( -5.2 - 3.1)E 1 (0/ 18) (0/ 6) (0/ 12) Cs-137 (30) 100 4.4E O 07 8.9E O -4.8E O (0) ( -3.2 - 5.1)E 1 ( 0.0 - 1.6)E 1 ( -3.2 - 2.2)E 1 (0/ 18) (0/ 6) (0/ 12) Ba-140 (30) -4.3E 1 07 9.6E 1 -5.2E 0 (0) ( -4.6 - 3.0)E 2 ( -3.5 - 29.9) E 1 ( -1. 9 - 2. 6) E 2 (0/ 18) (0/ 6) (0/ 12) Co.141 (30) 1.2E 0 C2 2.8E 1 1.3E 1 (0) ( -5.1 - 5.5)E 1 ( -4.6 - 55.4)E O ( -7.4 - 7.1)E 1 (0/ 18) (0/ 6) (0/ 12) Co-144 (30) -3.2E 1 02 1.2E 1 -4.1E 1 (0) ( ~1.8 - 1.3)E 2 ( -1.8 - 1.3)E 2 ( -1.9 - 1.6)E 2 (0/ 18) (0/ 6) (0/ 12) Th-232 (30) 5.4E 2 52 1.2E 3 7.6E 2 (0) ( 1.1 - 15.7)E 2 ( 4.5 - 22.0)E 2 ( 2.9 - 22.0)E 2 (12/ 18) (6/ 6) (10/ 12) i l'
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
" The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations)is shown in parentheses, j I
J J l I
)
J
I: 1: 1 I-G) Fish Semiannual fish and invertebrate samples are required from two I locations. .This section presents the results for fish sampling only. l Invertebrate results may be found in sections entitled Lobsters and ! Shellfish. Samples were collected from two locations quarterly. A I gamma analysis was performed on each sample. l i During the year the fish species collected from station no.03 were
. Winter Flounder and skate. Species collected from station no.53 were also Winter Flounder and skate.
In 1998 the only radionuclide detected in fish samples was natural occurring K-40.- l 1 l l e l l l 1-I 42 s
Radiological Environmental Program Summary Seabrook Nuclear Power Station. Seabrook, NH (January December 1996) MEDIUM: Fish (FH) UNITS: pCL/ka
!afc.*t.oLS!* loa *.. 8tauon yg,Hig9es( uesn ... , , , , ,, 9,9,n,igi,Si,a, tan.,,,,
. Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. De'ected") (No. Detected **) (No. Detected **) Be-7 (9) -8.0E 1 53 2.0E O 2.0E O (0) ( -2.0 - 0.3)E 2 ( -0.8 - 9. 5)E 1 ( -8.8 - 9.5)E 1 (0/ 4) (0/ 5) (0/ 5) K-40 (9) 2.*E 3 53 3.3E 3 3.3E 3 (0) ( 1.b - 3.7)E 3 ( 2.2 - 3.7)E 3 ( 2.2 - 3.7)E 3 (4/ 4) (5/ 5) (5/ 5) Cr-51 (9) -3.7E o 03 -3.75 0 -2.8E 1 (0) ( -8.2 - 8.8)E 1 ( -0.2 - 8.8)E 1 ( -1.4 - 1.1)E 2 (0/ 4) (0/ 4) (0/ 5) ! Mn-54 (9) 130 1.3E o 03 1.3E O -6.0E O (0) ( -3. 8 - 3 8. 6) E -1 ( -3.8 - 38.6) E -1 ( -1.5 - 0.7)E 1 (0/ 4) (0/ 4) (0/ 5) l
)
Co-57 (9) 1.9E -1 53 2.1E 0 2.1E O (0) ( -1.5 - 1.0)E 1 ( -2. 8 - 11.7) E O ( -2.8 - 11.7)E o (0/ 4) (0/ 5) (0/ 5) Co-58 (9) 130 4.5E o 03 4.5E O -2.0E O (0) ( -2.6 - 20.4)E O ( -2.6 - 20.4)E O ( -1.1 - 0.3)E 1 (0/ 4) (0/ 4) (0/ 5) Fe-59 (9) 260 2.0E 1 03 2.0E 1 -3.7E 0 (0) ( -1.3 - 5.7)E 1 ( -1.3 - 5.7)E 1 ( -4.6 - 2.5)E 1 (0/ 4) (0/ 4) (0/ 5) Co40 (9) 130 1.9E 0 03 1.9E O -2.6E O (0) ( -4.9 - 8.7)E 0 ( -4.9 - 8.7)E O ( -2.1 - 0.5)E 1 (0/ 4) (0/ 4) (0/ 5) Zn45 (9) 260 7.7E o 03 7.7E 0 -1.5E 1 (0) ( -2.3 - 2.3)E 1 ( -2.3 - 2.3)E 1 ( -5.3 - 1.7)E 1 (0/ 4) (0/ 4) (0/ 5) So-75 (9) 6.7E o 03 6.7E 0 5.3E 0 (0) ( 2.0 - 11.0)E O ( 2.0 - 11.8)E 0 ( -1.7 - 15.0)E O (0/ 4) (0/ 4) (0/ 5) Zr-95 (9) 5.35 0 53 6.6E O 6.6E 0 (0) ( -1.8 - 2.2)E 1 ( -1. 6 - 2. 9) E 1 ( -1.6 - 2.9)E 1 (0/ 4) (0/ 5) (0/ 5) Ru-103 (9) 4.3E o 03 4.3E 0 -5.7E O (0) ( -5.6 - 12.1)E O ( -5.6 - 12.1)E O ( -2. 9 - 0. 9)E 1 (0/ 4) (0/ 4) (0/ 5)
Radiological Environmental Prograrn Summary Seabrook Nuclear Power Station, Seabrook, NH (January December 1998) MEDIUM: Fish (FH4 UNITS: DCl/kn b.?dbN"* . ation
...,,,, ,{,,Q,y,p,g,st d y,ean ,,, , , gont,ro,1,St,a,t,so,ns,,,,
Radionuclides Mean Sta. Men't Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected **) (No. Detected") (No. Detected") Ru-106 (9) 4.0E 1 03 4.0E 1 1.3E 1 (0) ( -6.0 - 9.9)E 1 ( -6.0 - 9.9)E 1 ( -4.7 - 6.1)E 1 (0/ 4) (0/ 4) (0/ 5) Ag 110M (9) -3.5E O 53 -7.9E -1 -7.9E -1 (0) ( -1.4 - 1.0)E 1 ( -2.3 - 1.2)E 1 ( -2,3 - 1.2)E 1 (0/ 4) (0/ 5) (0/ 5) Sb-124 (9) 5.0E o 53 7.0E o 7.0E o (0) ( -1.4 - 4.1)E 1 ( -1.4 - 2.2)E 1 ( -1.4 - 2.2)E 1 (0/ 4) (0/ 5) (0/ 5) e-131 (9) 1.3E 1 03 1.3E 1 9.4E 0 (0) ( -2.7 - 38.9)E 0 ( -2.7 - 38.9)E O ( -1.5 - 8.3)E 1 (0/ 4) (0/ 4) (0/ 5) Cs.134 (9) 130 -2.0E 0 03 -2.0E o -8.0E o (0) ( -8.1 - 3.3) E O ( -0.1 - 3.3)E O ( -1.7 - 0.6)E 1 (0/ 4) (0/ 4) (0/ 5) Cs-137 (9) 150 4.1E o 03 4.1E o -8.4E -1 (0) ( 0.0 - 7.3)E O ( 0.0 - 7.3)E O ( -1.0 - 0.9)E 1 (0/ 4) (0/ 4) (0/ 5) Ba140 (9) -4.7E o 53 5.1E O 5.1E O (0) ( -1.9 - 0.7)E 1 ( -2.8 - 5.6)E 1 ( -2.8 - 5.6)E 1 (0/ 4) (0/ 5) (0/ 5) Co-141 (9) -1,2E 1 53 9.6E 0 9.6E O (0) ( -2.2 - 0.4)E 1 ( -7.8 - 37.3)E O ( -7.8 - 37.3)E 0 (0/ 4) (0/ 5) (0/ 5) Co-144 (9) -2.8E 1 53 9.7E O 9.7E O (0) ( -6.1 - 1.8)E 1 ( -5.4 - 10.0)E 1 ( -5.4 - 10.0)E 1 (0/ 4) (0/ 5) (0/ 5) Th-232 - (9) 4.7E 1 53 5.6E 1 5.6E 1 (0) ( -1. 8 - 12. 5) E 1 ( 3.3 - 10.4)E 1 ( 3.3 - 10.4)E 1 (0/ 4) (0/ 5) (0/ 5)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in OOCM Table A.5-3.
** The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations)is shown in parentheses.
H) Lobeters Semiannual fish and invertebrate samples were required from two locations.. This section provides the results for one type of invertebrate - American lobsters. Fish and other invertebrate results may be found in the sections entitled Fish and Shellfish, respectively. A gamma analysis was performed on each sample. A Lobster sample from the area of the discharge was not available for collection during the-fourth quarter of the year. The only radionuelide detected in lobster samples in 1990 was natural occurring K-40. l l I l 45 i
~
I l i Radiological Environmental Program Summary Seabrook Nuclear Power Station, Seabrook, NH (January . December 1998) MEDIUM: American Lobster (HA) UNITS: DCl/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected") (No. Detected **) Be-7 (3) -2.0E 1 04 -2.0E 1 -4.4E 1 (0) ( -1,3 - 0.5)E 2 (0/ 1) (0/ 1) (0/ 2) K 40 (3) 2.0E 3 54 2.2E 3 2.2E 3 (0) ( 1.8 '2.5)E 3 ( 1.8 - 2.5)E 3 (1/ 1) (2/ 2) (2/ 2) Cr 51 (3) 5.7E 1 04 5.7E 1 -2.6E 1 (0) ( -2.8 - -2. 4) E 1 (0/ 1) (0/ 1) (0/ 2) Mn-54 (3) 130 5.7E o 04 5.7E O -3.8E O (0) ( -5.0 - -2.6)E O (0/ 1) (0/ 1) (0/ 2) Co-57 (3) -4.2E o 54 4.1E O 4.1E O (0) ( 1.4 - 6.9)E O ( 1. 4 - 6. 9) E O (0/ 1) (0/ 2) (0/ 2) Co-58 (3) 130 -1.4E 1 54 -3.3E o -3.3E o (0) ( -1.3 - 0.6)E 1 ( -1.3 - 0.6)E 1 i (0/ 1; (0/ 2) (0/ 2) l Fe-59 (3) 260 -6.6E O 04 -6.6E O -1.5E 1 l (0) ( -5.7 - 2. 6)E 1 (0/ 1) (0/ 1) (0/ 2) ) i' Co-60 (3) 130 -2.6E 1 54 -7.1E O -7.1E O (0) ( -1.2 - -0.2)E 1 ( -1.2 - -0.2)E 1 (0/ 1) (0/ 2) (0/ 2) Zn-65 (3) 260 2.8E 1 04 2.8E 1 2.0E 1 (0) ( -3.1 - 43.1)E O ] (0/ 1) (0/ 1) '(0/ 2) l So 75 (3) -5.5E O 54 1.2E o 1.2E O (0). ( -4.1 - 6.4)E o ( -4.1 - 6.4)E O (0/ 1) (0/ 2) (0/ 2) Zr-95 (3) 1.1E 1 04 1.1E 1 -3.9E -1 , ( -7.7 - 0.0)E -1 l (0) (0/ 1) (0/ 1) (0/ 2) Ru-103 (3) ,
-4.7E -1 04 -4.7E -1 -2.8E O (0) ( -0.0 - 2.5)E O (0/ 1) (0/ 1) (0/ 2)
\; ,
Radiological Environmental Program Summary Seabrook Nuclear Power Station. Seabrook, NH (January December 1998) MEDIUM: American Lobster (MA) UNITS: oCi/ka ["dpagg,a,tgns,,, , , ,Station,g(g,F1g,gy,st y,ean
,, , , , C,ontrol S,g,g,o,ns,,,,
Radionuclides Mean Sta Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected **) (No. Detected") Ru 106 (3) -6.3E 1 54 8.3E 1 8.3E 1 (0) ( 6.8 - 9.7)E 1 ( 6.8 - 9.7)E 1 (0/ 1)' (0/ 2) (0/ 2) Ag 110M (3) -1.6E 1 54 -5.1E O -5.1E 0 (0) ( -5.5 - -4.7)E 0 ( -5.5 - -4.7)E 0 (0/ 1) (0/ 2) (0/ 2) 3 Sb-124 (3) 1.1E 1 04 1.1E 1 8.4E o (0) ( 1.1 - 15.8)E o (0/ 1) (0/ 1) (0/ 2) 1-131 (3) -4.6E 1 54 -1.5E 1 -1.5E 1 (0) ( -1. 6 - -1. 3) E 1 ( -1.6 - -1.3)E 1 (0/ 1) (0/ 2) (0/ 2) Cs-134 (3) 130 -1.5E O 04 -1.5E 0 -1.6E O (0) .( -1.8 - -1.4)E O (0/ 1) (0/ 1) (0/ 2) Cs.137 (3) 150- -3.0E o 54 -3.0E o -3.0E o (0) ( -1.1 - 0.5)E 1 ( -1.1 - 0.5)E 1 (0/ 1) (0/ 2) (0/ 2) Ba-140 (3) 4.2E o 04 4.2E O -4.9E 0 (0) ( -7.8 - -2.0)E O (0/ 1) (0/ 1) (0/ 2) Co-141 (3) 7.3E -1 04 7.3E -1 -2.0E 1 (0) ( -3.4 - -0.6)E 1 (0/ 1) (0/-1) (0/ 2) Co 144 (3) -8.7E O 04 -8.7E o -8.8E o (0) ( -1.9 - 0.1)E 1 (0/ 1) (0/ 1) (0/ 2) Th-232 (3) 1.8E 1 04 1.8E 1 1.2E O (0) ( -6.5 - B.8)E 0 (0/ 1) (0/ 1)- (0/ 2)
- Non-Routine refers to those radionuclides that exceeded the Reporting Leve!s in ODCM Table A.5-3.
" The fraction of sample analyses yielding detectable measurements (i e. >3 standard deviations) is shown in parentheses.
I) Shellfish semiannual fish and invertebrate samples are required from two locations. This section provides the results for shellfish samples only. Fish and other invertebrate results may be found in the sections entitled Fish and Lobsters, respectively. A gamma analysis was performed on each sample. The only radionuclide detected in shellfish samples in 1998 was natural occurring K-40. l i l 1 l 4 dS
Radiological Environmental Program Summary Seabrook Nuclear Power Station. Seabrook. NH (January . December 1998) MEDIUM: Mussel (MU) UNITS: DCi/ka indicator Stations Station With Hghest Mean Control Stations Radionuclides -Mean Sta. Mean Mean (No. Analyses) Required Range Range - Range (Non-Routine *) LLD (No. Detected **) (No. Detected **) (No. Detected") Be-7 - (8) 4.8E 1 58 1.1E 2 6.5E 1 (0) ( -2.1 - 10. 9) E 1 ( 2.0 - 19.0)E 1 ( -6.1 - 19.0) E 1 i (0/ 4) (0/ 2) (0/ 4) K.40 (8) 9.6E 2 09 1.2E 3 8.7E 2 (0) ( 6.3 - 13.0)E 2 ( 1.1 - 1.3)E 3 ( 4.4 - 12.3)E 2 (3/ 4) (2/ 2) (3/ 4) Cr51 (8) -9.25 1 59 -3.4E 1 -3.6E 1 (0) ( -1.6 - -0.2)E 2 ( -1.4 - 0.7)E 2 ( -1.4 - 0.7)E 2 (0/ 4) (0/ 2) (0/ 4) Mn-54 (8) 130 -6.3E o 09 -4.4E o -7.2E O (0) ( -1. s - 0.1)E 1 ( -5.0 - -3.s)E O ( -1.9 - 0.2)E 1 (0/ 4) (0/ 2) (0/ 4) Co (8) -4.1E -1 56 7.2E 0 1.5E 0 _(0) ( -5.9 - 5.9)E 0 ( 5.0 - 8.6)E O ( -1.2 - 0.9)E 1 (0/ 4) (0/ 2) (0/ 4) Co-68 (8) 130 2.5E O 09 3.9E 0 6.2E -1 (0) ( -1.2 - 1.5)E 1 ( 3.5 - 4,2)E O ( -4. 9 - 7.4) E O i (0/ 4) (0/ 2) (0/ 4) l Fe-59 (8) 260 -9.3E -1 09 1.3E 1 -1.4E 1 (0) ( -2.8 - 2.4)E 1 ( 7.1 - 244.1)E -1 ( -5.1 - 3.1)E 1 (0/ 4) (0/ 2) (0/ 4) Co-60 (8) 130 4.5E o 06 1.1E 1 -2.2E O (0) ( -1.1 - 2.2)E l'- ( 0.0 - 2.2)E 1 ( -2.5 - 0.9)E 1 (0/ 4) (0/ 2) (0/ 4) Zn-65 (8). 260- 6.2E O 56 1.0E 1 -1.6E 1 (0) ( -3.4 - 4.0)E 1 ( -2.0 - 205.6)E -1 ( -7.4 - 2.1)E 1 (0/ 4) (0/ 2) (0/ 4) So-75 (8) 4.5E o 06 1.1E 1 1.9E 0 (0) ( -7.7 - 12.6)E O ( 9.4 - 12.6)E 0 ( -8,5 - 12.4)E O (0/ 4) (0/ 2) (0/ 4) Zr-95 (8) 8.8E 0 06 2.1E 1 4.6E o j (0) '( -2.1 - 2.1)E 1 ( 2.1 - 2.1)E 1 ( -1. 9 - 2.2) E 1 (0/ 4) (0/-2) (0/ 4) Ru-103 (8) 3.22 0 06 1.1E 1 -1.0E 1
~
(0) -( -6.4 - 14.9)E o ( 6.5 - 14.9)E 0 ( -2.9 - 0.2)E 1 (0/ 4) (0/ 2) (0/ 4)
f-L l , Radiological Environmental Program Summary Seabrook Nuclear Power Station. Seabrook, NH (January . December 1998) MEDIUM: Mussel (MU) UNITS: pC1/ka
$d3.' '8 ".'.. .. tat ,,p,n,gtg,H,, igg,2t y,ean , ,, ,,, , , , C,o,n,tt,o,1,p,a,t,io,ns,,,,
Radionuclides Mean- Sta. Mean l Mean l (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected **) (No. Detected") (No. Detected") l Ru-106 - (8) _ ~
-2.0E -1 59 6.4E 1 1.4E 1 l'
(0) ( -8. 8 - 11. 9) E 1 ( -4.6 - 17.5)E 1 ( -4.6 - 17.5)E 1
., (0/ 4) (0/ 2) (0/ 4) -
Ag-110M (8) -4.1E o 09 3.8E o -8.6E o (0) ( -2.0 - 0.6)E 1 (. 1.5 - 6.0)E O ( -1,7 - 0.5)E 1 (0/ 4) (0/ 2) (0/ 4) Sb-124 (8) -1.4E 1 09 2.8E 0 -9.5E 0 (0) ( -4.0 - 1.5)E 1 ( -9.3 - 14.8) E 0 ( -4.0 - 1.4)E 1 (0/ 4) '(0/ 2) (0/ 4) 1-131 (8) -9.8E o 56 3.4E 1 2.3E 1 (0) ( -6.6 - 2.5)E 1 ( i.8 - 5.0)E 1 ( -5.8 - 5's.0)E O (0/ 4) (0/ 2) (0/ 4) Cs-134 (8) 130 2.3E O 09 _1.1E 1 4.1E o
- (0) ( -1.2 - 1. 6) E 1 - ( 5.8 - 15.6)E 0 ( -3.3 - 16.9)E O l (0/ 4) (0/ 2) (0/ 4)
~
Cs 137 (8); 150- 8.7E -1 06 2.7E o -4.0E O (0) ( -7.1 - 6.9)E O ( -1.5 - 6.9)E O ( -1.8 - 0.7)E 1 (0/ 4) (0/ 2) (0/ 4) Ba-140 (8) -1.5E 1 56 0.5E o 4.8E o (0) ( -5.7 - 0.8)E 1 ( -7.0 - 24.0)E.0 ( -2.1 - 2.4)E 1 (0/ 4) (0/ 2) (0/ 4) Co-141 (8) -1.4E 1 59 1.2E 1 6.4E O (0) ( -4.2 - 0.8)E 1 (' 2.0 - 22.2)E 0 ( -7.0 - 22.2)E 0 (0/ 4) (0/ 2) (0/ 4) Co-144 (8) 3.2E 1 09 3.3E 1 -1.5E 1 (0) ( -4.3 - 70.4)E O ( -4.3 - 70.4)E O ( -4.5 - 3.1)E 1 (0/ 4) (0/ 2) (0/ 4) Th-232 (8) 4.3E o 06 1.1E 1 -1.2E 1 (0) ( -3.3 - 5.4)E 1 ( -3.3 - 5.4)E 1 ( -5.4 - 1.7)E 1 (0/ 4) (0/ 2) (0/ 4)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
" The fraction of sample analyses yieldeg .ute measurements (i.e. >3 standard deviations) is shown in parentheses.
J) Irish Hoss There is no requirement to collect Irish Moss samples. Semiannual samples were collected from two locations. A gamma analysis was performed on each sample. The only radionuclides detected in 1998 were naturally occurring Be-7 and K-40.
'51
Radiological Environmental Program Summary Seabrook Nuclear Power Station. Seabrook, NH (January December 1998) MEDIUM: Irish Moss (AL) UNITS: rgkg indsator Stations Station With Hig.*.ast Mean Control Stations Radionuclides Mean Sta Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected **) (No. Detected") Be 7 (4) 2.5E 2 05 2.5E 2 1.6E 2 (0) ( 1.5 - 3.5)E 2 ( 1.5 - 3.5)E 2 ( 5. 3 - 314. 4) E o (1/ 2) (1/ 2) (0/ 2) K-40 (4) 6.9E 3 05 6.9E 3 6.4E 3 (0) ( 6.6 - 7.3)E 3 ( 6.6 - 7.3)E 3 ( 5.7 - 7.1)E 3 (2/ 2) (2/ 2) (2/ 2) Cr-51 (4) -8.4E 1 05 -8.4E 1 -1.1E 2 (0) ( -1.5 - -0.2)E 2 ( -1.5 - -0.2)E 2 ( -1. 3 - -0. 9) E 2 (0/ 2) (0/ 2) (0/ 2) Mn-54 (4) 3.5E o 05 3.5E O -7.1E O (0) ( -3.2 - 10.2)E O ( -3.2 - 10.2)E 0 ( -1,6 - 0.1) E 1 (0/ 2) (0/ 2) (0/ 2) Co-57 (4) -1.7E 0 55 1.5E O 1.5E O (0) ( -6.2 - 2.8)E O ( -5.1 - 8.0)E O ( -5.1 - 8.0)E O (0/ 2) (0/ 2) (0/ 2) Co-58 (4) 3.5E 0 05 3.5E O -8.7E D (0) ( -9.6 - 78.8)E -1 ( -9.6 - 18.8)E -1 ( -1.4 - -0.4)E 1 (0/ 2) (0/ 2) (0/ 2) ! Fe-59 (4) -2.3E 1 55 3.6E 1 3.6E 1 (0) ( -4.9 - 0.3)E 1 ( 1.6 - 70.2)E 0 ( 1.6 - 70.2)E 0 j (0/ 2) (0/ 2) (0/ 2) Co-60 (4) 1.2E O 55 2.0E o 2.0E o (0) ( -2.3 - 4.8)E o ( -6.5 - 10,5)E o ( -6.5 - 10,5)E O (0/ 2) (0/ 2) (0/ 2) ! Zn-55 (4) 2.4E 1 55 2.9E 1 2.9E 1
< 2.2 - 2.7)E 1 l (0) ( -6.1 - 63.4)E o ( -6.1 - 63.4)E o (0/ 2) (0/ 2) (0/ 2)
Se 75 (4) -2.0E O 55 7.4E O 7.4E 0 (0) ( -8.3 - 4.3)E O ( 2 . 9 - 11. 9) E O ( 2.9 - 11.9)E O (0/ 2) (0/ 2) (0/ 2) Zr-95 (4) 7.3E o 05 7.3E O -1.4E 1 (0) ( 1.4 - 13.2)E O ( 1.4 - 13.2)E O ( -2.5 - -0.2)E 1 (0/ 2) (0/ 2) (0/ 2) Ru 103 (4) -2.6E -1 05 -2.6E -1 -4.8E O (0) ( -7.6 - 7.1)E o ( -7. 6 - 7.1) E O ( -2. 6 - 1. 6) E 1 (0/ 2) (0/ 2) (0/ 2)
'\
Radiological Environmental Program Summary
)
Seabrook Nuclear Power Station, Seabrook, NH (January . December 1998) MEDIUM: Irish Moss (AL) UNITS: pCi/ka i.nd.ic.a.t.or Statens . Station With Highest Mean ) C..o..n.t.r.o.l.S.ta.t.io.n.s....
)
- Radionucides Mean Sta. Mean Mean
. (No. Analyses) Required Range Range Range q (Non-Routine *) LLD (No. Detected **) (No. Detected **) (No. Detected")
Ru.106 (4) -3.8E 1. 05 -3.8E 1 -1.1E 2 3 (0) ( -1. 2 - 0. 5) E 2 ( -1.2 - 0.5)E 2 ( -1.9 - -0.2)E 2 4 (0/ 2) (0/ 2) (0/ 2) Ag.110M (4) -1.2E 1 05 ~1.2E 1 -1.3E 1 (0) ( -1.4 - -0.9)E 1 ( -1. 4 - -0. 9) E 1 ( -1.8 - -0.8)E 1 I (0/ 2) (0/ 2) (0/ 2) Sb.124 (4) 5.1E 0 55 9.3E O 9.3E O l (0)' ( -6.3 - 16.5)E o ( -1.6 - 3.5)E 1 ( -1.6 - 3.5)E 1 (0/ 2) (0/ 2) (0/ 2) 1131 (4) -3.1E 1 55 5.0E 1 5.0E 1 (0) ( - 9.1 - 2.8)E 1 ( 2.3 - 7.7)E 1 ( 2.3 - 7.7)E 1 (0/ 2) (0/ 2) (0/ 2) Cs.134 (4) -3.7E O 55 1.0E 1 1.0E 1 (0) ( -5.2 - -2.3) E 0 ( 5.4 - 14.7)E O ( 5.4 - 14.7)E O (0/ 2) (0/ 2) (0/ 2) Ca.137 (4) 1.1E 1 05 1.1E 1 9.6E O (0) ( 2.6 - 19.0)E O ( 2.6 - 19.0)E O ( -1.8 - 21.1)E 0 l (0/ 2) (0/ 2) (0/ 2) i Ba.140 (4) -8.8E o 05 -B.8E D -4.1E 1 (0) ( -3.4 - 1.6)E 1 ( -3.4 - 1.6)E 1 ( -1.1 - 0. 3) E 2 (0/ 2) (0/ 2) (0/ 2) Co.141 (4) 4.6E O 55 1.8E 1 1.8E 1 (0) ( 3.9 - 5.3)E 0 ( -1.7 - 5.2)E 1 ( -1.7 - 5.2)E 1 (0/ 2) (0/ 2) (0/ 2) Oe.144 (4) 2.6E 1 05 2.6E 1 -3.4E 1 _(0) ( 1.4 - 3.8)E 1 ( 1.4 - 3.8)E 1 ( -8. 3 - 1. 6) E 1 (0/ 2) (0/ 2) (0/ 2) Th.232 (4) 7.3E 1 06 7.3E 1 6.4E 0 (0) ( 7.1 - 7.5)E 1 ( 7.1 - 7.5)E 1 ( 0.0 - 1.3)E 1 (0/ 2) (0/ 2) (0/ 2)
- Non. Routine refers to those radionuclides that exceeded the Reporting Levels in OOCM Table A.5-3.
" The fraction of sample analyses yielding detadable measurements (i.e. >3 standard deviations) is shown in parentheses. l l
s. l
K) Food Crop There is no requirement for food crop samples.as long as the required milk locations are available. Samples are collected from three locations in the growing season months of June, July and August. Strawberries, peas, wax beans, tomatoes and corn were collected The only radionuclide detected in 1998 was natural occurring K-40. l l l l l l
)
I l l i l l 54
Radiological Environmental Program Sunimary Seabrook Nuclear Power Station. Seabrook, NH (January . December 1998) MEDIUM: Food Crop (TF) UNITS: oCilka 5 '".dj,c,a,t,gr
. Stahons,, S tio,g,{,,g,y,p,}est ,,g,, 4 y,ean , , , , , , , C,o,n,y,o,1,S,t,a,tj,o,ns,,,,
Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range (Non-Routine *) LLD (No. Detected") (No. Detected") (No. Detected") l Be.7 (10.' 5.5E 1 01 1.2E 2 8.8E 1
'(0) ( -2.6 - 14.5)E 1 ( 3.5 - 132.6)E 0 (0/ 7) (0/ 1) (0/ 3)
K-40 (10) 2.1E 3 03 2.6E 3 1.7E 3 (0) ( .4 - 4.1)E 3 ( 1.7 - 4.1)E 3 ( 1. 6 - 1. 9) E 3 (7/ 7) (3/ 3) (3/ 3) Cr.51 (10) -5.3E 1 06 1.6E 1 1.6E 1 (0) ( -2.2 - 0.1)E 2 ( -8.6 - 12.3)E 1 ( -8.6 - 12.3)E 1 (0/ 7) (0/ 3) (0/ 3) Mn-54 (10) 2.0E O 01 1.1E 1 -5.1E O (0) ( -5.1 - 10.8)E 0 ( -8,9 - -1. 9) E o (0/ 7) (0/ 1) (0/ 3) Co-57 (10) -1.1E O 01 3.9E o 2.9E O (0) ( -1.1 - 0.4)E 1 ( -1.2 - 5. 8) E O (0/ 7) (0/ 1) (0/ 3) Co-58 (10) 2.5E -1 01 1.5E 1 -3.6E O (0) ( -1.3 - 1.5)E 1 ( -2,1 - 0.5)E 1 I (0/ 7) (0/ 1) (0/ 3) Fe-59 (10) 1.0E 0 01 -4.2E 1 2.1E 0 (0) ( -2,2 - 4.2)E 1 ( -1.7 - 3.0)E 1 (0/ 7) (0/ 1) (0/ 3) Co-60 (10) -6.7E -1 03 4.4E O -4.3E -1 (0) ( -2.1 - 2.2)E 1 ( -2.1 - 2.2)E 1 ( -1.0 - 0.5)E 1 (0/ 7) (0/ '2) (0/ 3) b 4'd (10) 8.0E 0 01 1.7E 1 -1.5E -1 (0) ( -4.0 - 5.0)E 1 ( -1.6 - 2.8)E 1 (0/ 7) (0/ 1) (0/ 3)' Se 75 (10) 2.1E O 01 2.2E 1 -3.2E o (0) ( -2.8 - 2.2)E 1 ( -1.1 - 3.1) E 1 (0/ 7) (0/ 1) (0/ 3)
~
Zr-96 (10) 4.1E O 01 1.2E 1 -1.9E o (0) ( -7.0 - 21.4)E O ( -1.1 - 1.0)E 1 (0/ 7) (0/ 1) (0/ 3) Ru 103 (10) -6.0E o , 06 -3.2E o -3.2E o (0) ( -2.0 - 0.8)E 1 ( -8.6 - 3.4)E O ( -8.6 - 3.4)E O (0/ 7) (0/ 3) (0/ 3)
I Radiological Environmental Prograrr R6* n.r. Seabr', .,k Nuclear Power Station, Sv ,tw (January . December 199s MEDIUM: Food Crop iTF) UNITS: c@e Indicator Stations Station With Highe ..~Aean Control Stations,_, Radionuclides Mean Sta. Mean Mean (No. Analyses) Required Range Range Range l (Non-Routine *) LLD (No. Detected") (No. Detected") (No. Detected **) Ru-106 (10) -1.6E 1 03 3.5E 1 -2.0E 1 , (0) ( -1,3 - 0.8)E 2 ( 0.0 - 7. 9)E 1 ( -8.8 - 4.8)E 1 (0/ 7) (0/ 3) (0/ 3) Ag-110M (10) 2.8E o 02 9.5E o -9.6E O (0) ( -2.7 - 4.5)E 1 ( -2.7 - e .5) E 1 ( -1.8 - 0.6)E 1 (0/ 7) (0/ 3) (0/ 3) d Sb-124 (10) 3.0E O 03 1.3E 1 1.1E 1 (b) ( -4.4 - 2.2)E 1 ( 0.0 - 2.2)E 1 ( -3.5 - 4.5)E 1 j (0/ 7) (0/ 3) (0/ 3) 1-131 (11) 60 -1.1E O 06 9.7E O 9.7E 0 , (0) ( -4.0 - 2.7)E 1 ( -5.2 - 29.3)E O ( -5.2 - 29.3)E O (L/ 8) (0/ 3) (0/ 3) Cs-134 (10) 60 6.3E 0 03 1.1E 1 -7.2E 0
)
(0) ( -6.1 - 13.8)E O ( 9.0 - 13.8)E 0 ( -2,3 - 0.5)E 1 1 (0/ 7) (0/ 3) (0/ 3) Cs 137 (10) 80 -4.7E -1 03 7.2E 0 -9.3E O (0) ( -8. 8 - 15. 9) E O ( -2. 4 - 15. 9) E 0 ( -2.0 - 0.3)E 1 (0/ 7) (0/ 3) (0/ 3) Ba 140 (10) -3.4E O 02 1.3E O 2.7E (0) ( -1.4 - 1.5)E 1 ( -8.2 - 14.7) E 0 ( -1.0 - 1.1)E 1 (0/ 7) (0/ 3) (0/ 3) Co-141 (10) 1.7E O 01 2.3E 1 4.3E O (0) ( -3.4 - 2.3)E 1 ( 3,1 - 5.6)E 0 (0/ 7) (0/ 1) (0/ 3) Co-144 (10) 1.5E 1 03 4.2E 1 -2.5E 1 (0) ( -9.1 - 11.3)E 1 ( -1.7 - 11.3)E 1 ( -5.5 - 0. 9) E 1 (0/ 7) (0/ 3) (0/ 3) Th-232 (10) 1.1E 1 02 2.2E 1 -6. "1E O (0) ( -3.3 - 12.2)E 1 ( -3.3 - 12.2)E 1 ( -2.0 - 1.2)E 1 (0/ 7) (0/ 3) (0/ 3)
- Non-Routine refers to those radionuclides that exceeded the Reporting Levels in ODCM Table A.5-3.
" The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations)is shown in parentheses.
L) Direct Radiation Direct gamma radiation exposure was measured with thermoluminescent dosimeters (TLDs). Two TLD badges are placed at each of the monitoring stations (Each TLD badge has 3 CaSO 4 :Tm elements) . A total of forty-seven stations are located offsite, forty of which are required. All badges were collected and readout on a quarterly schedule. All exposure rates were normalized to a 91-day quarter. A swmmary of the data is l- shown in Table 3.1. Indicator location results are statistically ~ identical to control locations. In the second quarter, TLD badge #34 located in Exeter, NH was J inadvertently destroyed when the local Phone company removed the utility 1 pole for replacement. All other results are consistent with previous preoperational and operational data. j l 1 i 1 i 1 l 57 i
i TABLE 3.1 l l Environmental TLD Measurements Net Exposure in mR/ Standard Quarter (91 days) 1998 l Annual ! -Sta. 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Ave, i- Hg Descrietion Exo . g.JL. Exo. g.JL. h S.A . Exo. S.D, h TL-01 Brimmer's ',ane 15.2 10.8 17.1 1 0.8 17.0 1 0.6 16.4 10.8 16.4 TL-02 Landing Rcad 13.7 10.6 14.9 1 0.6- 15.0 1 0.7 14.8 1 1.0 14.6 TL-03 Glade Path 15.3 10.7 16.0 1 0.7 17.0 1 0.6 16.5 10.8 16.2
- TL-04 Island Path 15.2 10.7 16.0 1 1.4 16.5 1 0.5 16.2 1 0.8 16.0 l TL-05 Harbor Road 14.7 10.7 15.5 1 0.7 16.6 1 0.9 16.5 1 0.8 15.8 TL-06 Barge Landing 14.4 10.6 14.4 1 0.5 15.0 1 0.5 14.3 0.8 14.5 l TL-07 Cross Road 13.6 10.6 12.9 1 0.4 13.8 1 1.0 13.6 1 0.7 13.5 TL-08 Farm Lane 16.1 -1 0.9 15.5 1 1.3 16.0 1 0.9 16.0 0.9 15.9 TL-09 Farm Lane 16.2 10.7 16.3 0.8 16.6 1 0.9 16.9 2 1.0 16.5 TL-10 Site Boundary 16.5 10.8 16.9 1 0.6 17.9 1 0.6 17.7 1 0.9 17.3 TL-11 Site Boundary 14.6 10.9 14.3 1 0.6 15.1 1 0.6 15.4 2 0.9 14.9 TL-12 Site Boundary 17.2 10.7 19.2 2 1.7 19.7 1 0.9 18.9 2 1.0 18.8 TL-13 Inside Site Boundary 18.8 10.9 19.2 2 1.0 20.2 1 0.7 20.2 1 1.2 19.6 TL-14 Trailer Park 15.2 10.8 15.6 2 0.5 15.9 1 0.9 15.9 1 1.0 15.7 j TL-15 Brimmer's Lane 14.4 10.6 15.4 1 0.5 16.0 2 0.7 16.4 1 1.0 15.6 TL-16 Brimmer's Lane 13.7 10.7 14.0 1 0.5 14.0 1 0.6 14.7 20.9 14.1 TL-17 South Road 14.8 11.0 15.8 2 0.6 15.6 1 0.5 17.1 10.9 15.8 TL-18 Mill Road 13.9 10.8 14.4 1 0.6 14.4 1 0.6 15.6 1 0.9 14.6 TL-19 Appledore Avenue 16.0 10.6 15.4 1 0.7 15.2 1 0.6 16.8 1 0.9 15.9 TL-20 Ashworth Avenue 17.4 10.8 17.4 1 0.6 17.0 2 0.7 18.5 1 1.1 17.6 TL-21 Route 1A 15.8 10.7 15.9 1 0.8 15.0 1 0.5 16.4 1 1.1 15.8 TL-22 Cable Avenue 15.9 20.7 15.7 1 0.5 15.2 1 0.5 16.2 1 0.9 15.8 i TL-23 Ferry Road 15.1 10.7 15.0 1 0.8 15.6 1 0.6 15.6 10.9 15.3 l
TL-24 Ferry Lots Lane 15.2 10.6 14.7 2 0.6 16.0 2 0.5 16.0 1 1.1 15.5 TL-25 Elm Street 16.9 10.8 16.5 1 0.6 16.0 1 0.7 16.8 1 1.1 16.6 TL-26 Route 107A 16.2 10.8 16.2 1 0.9 16.5 1 0.6 17.6 1 1.0 16.6 TL-27 Highland Street 15.7 10.6 15.9 1 0.8 15.8 1 0.6 16.8 1 1.0 16.1 TL-28 Route 150 15.5 10.9 16.5 1 0.7 17.6 1 0.6 16.9 10.9 16.6 l TL-29 Frying Pan Lane 16.2 10.7 16.5 0.5 16.3 0.9 17.5 1 1.0 16.6 s TL-30 Route 27 15.0 10.6 15.8 0.6 15.8 1 0.6 16.6 1 0.9 15.8 TL-31 Alumni Drive 14.'2 0.6 14.8 2 0.7 14.6 1 0.6 15.3 1 0.9 14.7 TL-32 SB Elementary School 17.3 20.7 17.6 1 0.9 17.1 1 0.6 18.0 :1.1 17.5 TL-33 Dock Area 18.6 10.7 18.6 1.4 17.8 1 0.5 18.7 2 0.9 18.4 3 TL-34 Bow Street 18.6 0.8 (1) 18.6 2 0.6 19.2 1.0 18.8 ! TL-35 Lincoln Ack. School 17.4 10.7 18.1 1 0.8 18.3 2 0.7 18.9 1.1 18.2 TL-36 Route 97(Control) 16.6 10.7 16.6 2 1.0 16.5 2 0.5 17.3 2 1.1 16.8 i i TL-37 Plaistow, NH (Control) 15.8 1.6 16.6 1 0.8 16.6 1 0.7 16.8 1 0.9 16.5 j TL-38 Hampstead, NH (Control) 15.2 10.8 17.0 1 0.9 16.9 2 1.0 17.9 1 1.4 16.8 TL-39 Fremont, NH (Control) 17.3 11.0 19.5 1 0.7 20.2 0.8 19.3 1 1.2 19.1 TL-40 Newmarket, NH (Control) 14.6 0.6 15.5 1 1.3 16.0 2 0.5 15.8 10.8 15,5 i 1 I l 58
i I l I TABLE 3.1 l l Environmental TLD Measurements l
!!et Exposure in mR/ Standard Quarter (91 days) 1998 :
I Annual ' Sta. 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Ave. h Descrirtien h EJL. En . . LL. En. S.D. En. JUL. En, TL-41 Portsmouth. NH (Control) 15.2 10.9 15.4 1 0.5 15.3 1 0.4 15.5 1 0.9 15.4 TL-42 Ipswich, MA (Control) 14.1 10.6 14.2 1 0.5 13.6 1 0.9 14.3 1 0.8 14.1 ' TL-43 Pocks Road Landing 14.4 10.6 14.6 1 0.6 14.3 1 0.9 14.7 1 0.8 14.5 TL-44 SB Education center 15.1 10.9 15.2 1 0.6 15.1 1 0.4 15.3 1 0.9 15.2 TL-45 Hampton Fire Station 15.4 10.6 16.9 1 0.6 16.7 1 0.8 17.0 1 0.9 16.5 TL-46 SB Police Station 17.6 10.8 17.0 1 0.5 16.6 1 0.6 17.3 1 1.0 17.1 TL-47 Route 84 15.2 10.8 16.0 1 0.7 15.8 1 0.7 15.9 1 0.9 15.7 Mean of Indicators 15.7 16.0 16.2 16.6 16.2 Mean of controls 15.5 16.4 16.4 16.7 16.3 (1) TLD Missing l l l l l l 59
Q FIGURE 3.6 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 - 30 u - 3 y . D _
" 20~ -20 ~
a .
.-L -g --- _ .
0 1 j - 10 -- 10 e 0 , -- 0 Jan Apr Jul Oct Jan Retrieval Date (1998)
-O- TL-01 Brimmer's Lane -o- TL-02 Landing Road -A- TL-03 Glade Path c TL-04 Island Path -v *L-05 Harbor Road 60.
I i I-FIGURE 3.6.1 l I ENVIRONMENTAL RADIATION MEASUREMENTS (USING-TLDs) SEABROOK STATION j , 40 , 40 ;
- L l w
~ ~
30 - - 30
~
7 - L t - E ,
# 20- L 20 10 - --10 F
iy N ! 0- 3 0
'1985 1987 1989 1991 1993 1995 1997 1999 -O- TL-01 Brimmer's Lane -O- TL-02 Landing Road 3- TL-03 Glade Path - o- TL-04 Island Path -y- TL-05 Harbor Road 61.
l I FIGURE 3.7 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) d l 1 SEABROOK STATION l l 40 -- 40
- j 30 - -30 c - _
( - 7 2 0 -- -20 a q - y _ Cl. - 3-== _ -Q __~Z-~_ j g g~ 5 _.__ g
-ka E O 10 - -10 1
0- 0 Jan Apr Jul Oct Jan Retrieval Date (1998)
'O- TL-06 Barge Landing -o- TL-07 Cross Road e- TL-08 Farm Lane m- TL-09 Farm Lane -v- TL-10 Site Ecundary 62.
l
l 1 FIGURE 3.7.1 ENVIRONMENTAL RADIATION MEASUREMENT (USING TLDs) f SEABROOK STATION l l 40 ; 40 l E I r
~ ~
i I 30 - L 30 L
'r t -
F g .
- I 7 #
20- -20 0 0
- r-10
~
b i 0 , 0 1985 1987 1989 1991 1993 1995 1997 1999
-ty- TL-06 Barge Landing -o- TL-07 Cross Road . -a- TL-08 Farm Lane -o- TL-09 Farm Lane TL-10 Site Boundary 63.
i I i i l l j FIGURE 3.8 1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30- - 30 y - . ( - j - 20- _ __ __ re- g --20 e
~
o' ' ~ g ~3 b b E 10- - 10 J 0 ---
. 0 ,
Jan Apr Jul Oct Jan l Retrieval Date (1998) !
-o- TL-ll Site Boundary l -o- TL-12 Site Boundary j l -a- TL-13 Inside Site Boundary i -o- TL-14 Trailer Park ~ -v- TL-15 Brimmer's Lane l
l l 64 i ,
i FIGURE 3.8.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40- 40
~
i l 1 30- - 30 t -
- '$ ^
R { 20 7 ,,,, 3% 6,g4 4 P ggs 6 h20
; : w j a , e i 4 8 e rs o s ? 8 p a $ 8gg @g ,o g i s :
g O O O O - 10 - -10 i
~
l
- 'O o 1985 1987 1989 1991 1993 1995 1997 1999
-g .TL-11 Site Boundary -- o- TL-12 Site Boundary a- 'TL-13 Inside Site Boundary o- TL-14 Trailer Park -v-- TL-15' Brimmer's Lane l '65.
c l l l 1 FIGURE 3.9 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION l 40 40 ! 1 30- -30 o - ( _
" 20- -20 ^
Y
$ v v- . X -
c: f *C 0 10- - 10 ! 0 , 0 Jan Apr Jul Oct Jan Retrieval Date (1990)
-O- TL-16 Brimmer's Lane -o- TL-17 South Road --g - TL-18 Mill Road -o- TL-19 Appledore Avenue -y -- TL-20 Ashworth Avenue 66.
p .- l l 1 l
. FIGURE 3.9.1 ENVIRONMENTAL RADIATION-MEASUREMENTS (USING TLDs)
SEABROOK STATION 40 40
- 30 i u . }
0 u i
- l. g -
7 20-
-20 l u . V g y Vv v v 9 6 l
lfl88 h 9 A l 10 - 9 .- 10 l - 0 , ; -0 1985_ 1987 1989 1991- 1993 1995 ~ 1997 1999 t
--D- TL-16 Brimmer's Lane -o-- TL South Road f . --n- TL-18 Mill Road 4 -o-- TL-19 Appledore Avenue t . -y- TL-20 Ashworth Avenue f p i 67.
I l l 1 I l FIGURE 3.10 l l ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) l SEABROOK STATION l 40 40
'. 1 . l 30- -30 I ~
u l c . U - ca o -
" 20- -20 u
O E! f fi- -ep' - - I 10- -10 0 , ,
, i ; , , , , , 7 0 Jan Apr Jul Oct Jan Retrieval Date (1998) --g- TL-21 Route 1A -e- TL-22 Cable Avenue s TL-23 Ferry Road
- c. TL-24 Ferry Lots Lane
-v- TL-25 Elm Street -
68.
FIGURE 3.10.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30- -30 4 - .
?y -
7 20- -20 W _ o vv E O 10- - 10 0 , 0 1985 1987 1989 1991 1993 1995 1997 1999
-c- TL-21 Route 1A -o- TL-22 Cable Avenue g-- TL-23 Ferry Road -o- TL-24 Ferry Lots Lane 1 s -y- TL-25 Elm Street i
69.
FIGURE 3.11 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 - -30 u -
# 20-- -20 W .
D &-
-.._-m 5?lh e=.=,- tp B q -
10- -10 0 0. Jan Apr Jul Oct Jan Retrieval Date (1998) TL-26 Route 107A
-o- TL-27 Highland Street -a- TL-29 Route 150
[
-o- TL-29 Frying Pan Lane l --v- TL-30 Route 27 70.
f: l i
- FIGURE 3.11.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs)
SEABROOK STATION i
- 40 40
- L 30~ -30 N -
7 20- ,- 2 0 h!8,Gs gh #*P l N@8NEIIi 8f I
~
v 10 - - 10
- \ -0 . -_ o -
1985 1987 1989 1991- 1993 '1995 1997 1999 ,
-o- TL-26 Route 107A
! -o- TL-27 Highland Street
-a- TL-28 Route 150 -o-- TL-29 Frying Pan Lane ~ -v- TL-30 Route 27 71.
s FIGURE 3.12 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 - -30 t .
" 20- -20 p __. - p - =- - - - -
3==532D2$ - E ~~ ~~'O D' --O O- _ E 10 --10 0 0 Jan Apr Jul Oct Jan Retrieval Date (1998)
-O- TL-31 Alumni Drive -o-- TL-32 SB Elementary School -g-- TL-33 Dock Area o- TL-34 Bow Street -v- TL-35 Lincoln Ackerman Schoc.1 72.
FIGURE 3.12.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40- 40 30 -30 y - t - o - 8
'20-E
[ hg $A kN 'S Iho i 7 g sj.il4 ggfg g3 e gje.geso,08= sos 88e"{*eajsoe"=s;yo s ooo ; . 10 - ' 10 0 , Lo 1985 1987 1989 1991 1993 1995 1997 1999
-o- TL-31 Alumni Drive --o- TL-32 SB Elementary School a- TL-33 Dock Area
- o- TL-34 Bow Street t -
-y- TL-35 Lincoln Ackerman School 73.
I l l l t l l l l FIGURE 3.13 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 t J _ 30 H -30 0 - i 4J I u m - 3 _
# 20H % _.-
_7
-20 i u ~ ~
l O _A G -: - . _ . . _ _--y--__ _ _____h 9 cd - Y E 10 - - 10 1 l i - 0 0 l Jan Apr Jul Oct Jan Retrieval Date (1998)
--c-- TL-36 Route 97 (Control) -o- TL-37 Plaistow NH (Control) -n- TL-38 Hampstead NH (Control) %- TL-39 Fremont NH (Control) ~ - v-- TL-40 Newmarket NH (Control) 74.
a FIGURE 3.13.1 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 2 - 30- -30 g. O
~
Y _
- g. .
7 O #o -20
, 00b C#0 ho, 0 'O OC'o l BNt*ffY 'hg lYb 7
10 - - 10 1
~
0 0 1985~ 1987 1989 1991 1993 1995 1997 1999
-O- TL-36_ Route 97 (Control)
TL-37 Plaistow, NM (Control)
-A- TL-38 Hampstead NH (Control) . -o- TL-39 Fremont, NR (Centrol) -v- TL- 4 0 Newr_a r k e t , NH (Control) 75.
1 i l l 4 I FIGURE 3.14 ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 1 1 30 i -30 J _ e , _ u i u 1 - e ! a , 7 20- -20
] 2* - ~~4 _
g ; 5 L 19 j 10 ' ' 10 l i - d - 1 I O, O Jan Apr Jul Oct Jan Retrieval Date (1998)
-D- TL-41 Portsmouth NH (Control) l -o- TL-42 Ipswich MA (Control) m- TL-43 Rocks Road Landing q- TL-44 SB Education Center -v- TL-45 Hampton Fire Station -X- TL-46 SB Beacn Police Station TL-47 Hampton Falls, Route 84 76.
J
FIGURE 3.14.1 i ENVIRONMENTAL RADIATION MEASUREMENTS (USING TLDs) SEABROOK STATION 40 40 30 - -30 y - t - " 20- -20 h$ @b$h@ 10- -10
~
T 0 0 1985 1987 1989 1991 1993 1995 1997 1999 m- TL-41 Portsmouth, NH (Control)
-o- TL-42 Ipswich, MA (Centrol) --n-- TL-43 Rocks Road Landing o- TL-44 SB Education Center TL-45 Hampton Fire Station ~ -x- TL-46 SB Beach Police Station , TL-47 Hampton Falls, Route 84 77.
4.0 Quality Assurance Program The quality assurance program at the Duke Engineering & Services Environmental Laboratory is designed to serve two overall purposes:
- 1) Establish a level of confidence in the measurement process to assure the licensee, regulatory agencies and the public that analytical results are accurate and precise; and 2) Identify deficiencies in the sampling or the measurement process to those responsible for these operations so that corrective actions can be taken. Quality assurance is applied to all steps of the measurement process, including the collection, reduction, evaluation and the reporting of data, as well as the record keeping of the final results. Quality control, as part of the quality assurance program, provides a means to control and measure the characteristics of measurement equipment and processes, relative to established requirements.
The DESEL employs a comprehensive program to monitor the quality of analytical processing to ensure reliable environmental monitoring data. The program includes the use of approved and controlled procedures for all work activities, a nonconformance and corrective action tracking program, systematic internal audits, audits by external groups, a laboratory quality control program, and a staff training and retraining program. Monitoring programs include the Intralaboratory Quality control Program administered by the Laboratory QA of ficer (used in conjunction with National Institute Standards and Technology's Measurement Assurance Program, NIST MAP) and the third party interlaboratory programs administered by the US EPA and Analytics, Inc. These prograns are targeted to supply QC\QA sources at 5% of the routine sample analysis load. In addition, the Laboratory Quality Control Audit Committee conducts a blind duplicate quality assurance program. Environmental TLD Program The Panasonic environmental dosimeters are processed by the DESEL, which is a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory. The NVLAP is conducted through the Battelle Pacific Northwest Laboratories. The DESEL environmental TLD program has its own quality assurance program, through the Laboratory Quality Assurance Officer, as well as the NVLAP program. Under these programs, dosimeters are irradiated to ANSI specified testing criteria and submitted for processing to the Dosimetry Services Group as " unknowns". The bias and precision of TLD processing is measured against this standard and is used to indicate trends and changes in performance. Instrument checks, although routinely performed by the Dosimetry Services Group and representing between 5-10% of the TLD's processed, are not part of this report because they do not represent a true process check sample since the doses are known. The DESEL processed 3576 environmental TLD's in 1998. Ninety-six independent performance tests were conducted (2.7% QC). of these, 72 TLD's were submitted to the Dosimetry Services Group and 24 were submitted to the Battelle Pacific Northwest Laboratories testing program. All (100%), met the acceptance criteria for accuracy and precision with an average bias during the first half of 1998 of -0.1 +/- 2.5% and -1.9 +/- 3.3% for the second half of 1998. During 1998, a study was conducted to evaluate dosimeter mean bias response as a function of depth and dose level. The process was standardized by 'binning' dose levels into 100 mR increments starting with 0 mR out to 400 mR for high-energy irradiation (NVLAB Cat.IV). The percent bias was 0.81, 0.83 and -2.8 at dose levels of 0 - 100mR, >100-200mR & >300-400mR,respectively. 78
Intralaboratory Quality Control Program The DESEL conducts an extensive intralaboratory quality control program to assure the validity and reliability of the data. This program includes quality control of laboratory equipment, use of reference standards for calibration, and analysis of blank and iked samples. Process check samples are either samples submitted .uplicate to evaluate the precision of the measurement or spikou with a known quantity of radioactive material to assess the bias in the measurement. The records of the quality control program are reviewed by the c Laboratory QA Officer. Corrective measures are taken whenever applicable. A summary of the program process check results are found in Table 4.1. Two low-level iodine-131 results fell outside the laboratories acceptance criteria for bias and precision and one gamma result fell outside the laboratories criteria for bias, however since the mean bias for this set was within +/- 15% no further action was required. Two low-level iodine-131 in milk results fell outside the acceptance criteria for bias and precision. DESL confirmed the iodine activity by gamma analysis to be within 5% of the mean. A Condition Report (CR) CR98-009 was issued in December 1998, following the second failure (10/98). Third Party Intercomparison Program The DESEL also participates in two independent third party Intercomparison programs. At the end of 1995, the US EPA ended its Environmental Intercomparison Studies Program. To replace this mix of radionuclides and matrices, the DESEL now participates in two third party progranm; the US EPA Performance Evaluation (PE) Study for radionuclides in water and the Analytics Inc.'s Environmental Cross check Program for radionuclides in milk, water and on air filters. 1998 is the last year the EPA will provide PE samples for analysis. The overall scope of the Analytics program was designed to be comparable to the pre-1996 EPA program and reflects the mix of client REMP media processed by DESEL. Each sample supplied by the EPA or Analytics is analyzed in triplicate and the results are returned to the EPA or Analytics within a specified time frame. When the known values are returned to the Laboratory, the results are evaluated against specific Laboratory acceptance criteria and the EPA results are evaluated against EPA control limits. When results of the cross check analysis fall outside of the acceptance criteria or control limit, an investigation is initiated to determine the cause and, if appropriate, corrective measures are taken. EPA PE Program: During 1998,the DESEL analyzed 13 sample sets, representing 34 nuclides. The analysis included gamma emitters, gross alpha, gross beta, strontium-89&90, low-level iodine-131, tritium, radium-226 and 228 and natural uranium. Table 4.2 provides a summary of results for 1998. One set of EPA gross alpha analysis (ref date 1/30/98) fell outside the EPA control limits. The DESEL performed an investigation (Inquiry 3-98) to address the failure of the gross alpha samples. DESEL mean value: 9.8 pCi/L EPA known value: 30.50 +/- 7.60 pCi/L EPA control limits: 17.3-43.70 pCi/L The DESEL had previously determined the root cause of the low bias in gross alpha analysis to be sample evaporation and the amount of solids present in the sample. Follow up analysis of the EPA samples (EL 189-98) produced results within +6.6% and +5.9% of the known value with and 79
without celta rsep;ctivaly. In addition, DESEL procasosd a b:ckup sample from the 1/30/98 EPA PE sample. The results are DESEL mean values 17.95 pCi/L EPA known value 30.50 +/- 7.60 pC1/L EPA control limits: 17.30 - 43.70 pCi/L i 1 The Laboratory Quality Control Audit Committee (LQCAC) determined that no further action was necessary. ANALYTICS Program: 14 sets in water, milk, and air filter matrices were analyzed for as part of Analytics Cross Check Program. This analyses included gamma emitting nuclides, gross alpha, gross beta, strontium 89 and 90, low level iodine -131, tritium, radium-226 and 228, Plutonium 238 and 239, and uranium 234 and 238. Table 4.3 provides a summary of the results for 1998. All DESEL mean value results met the acceptance criteria for bias, however, two low level lodine 131 results with the following precision- 14.4% for milk and 16.8% for water contributed to the change of Inquiry 6-98 (investigation) to CR 98-009. l l During the preparation of this report, known values for the last three months of 1998 have not been returned to the Laboratory from either Analytics or the EPA. These data, when available, will be submitted as part of the 1999 submittal. Blind Duplicate Quality Assurance Progrant The Laboratory Quality Assurance Audit committee (LQCAC) is comprised of one member from each sponsor company that are serviced by the Duke Engineering and Services Environmental Laboratory. Two of the primary functions of the LQCAC are to conduct an annual audit of laboratory operations and to coordinate the Blind Duplicate Quality Assurance Program. Under the Blind Duplicate Quality Assurance Program, paired samples are submitted from the five plants, including the Seabrook Nuclear Power Station. They are prepared from homogeneous environmental media from each respective plant, and are sent to the Laboratory for analysis. The samples are ' blind' in that the identification of the matching sample is not identified to the Laboratory. The LOCAC analyzes the results of the paired analyses to evaluate precision in laboratory measurements. A total of 57 paired samples (Table 4.4) were submitted by the five DESEL sponsor company plants for analysis during 1998. The database used for the duplicate analysis consisted of paired measurements of 25 gamma-emitting nuclides, H-3, Sr-89, Sr-90, I-131 and gross beta. All measurements were evaluated, whether the results were considered statistically positive or not, and whether the net concentration was positive or negative. Of the 1492 paired duplicate measurements evaluated in 1998, 1486 (99.6%) fell within the established acceptance criteria. The total number of sample measurements completed as part of this program are listed in Table 4.5 80
TABLE 4.1
SUMMARY
OF PROCESS CONTROL ANALYSES RESULTS JANUARY-DECEMBER 1998 ACCURACY PRECISION I NUMBER OF NUMBER OF NUMBER OF ANALYSES NUMBER OF MIALYSES OUTSIDE SAMPLE MEDIA ANALYSIS OUTSIDE OF ANALYSES ACCEPTANCE ACCEPTMICE CRITERIA CRITERIA AIR CHARCOAL GAMMA 53 0 0 0 AIR FILTER BETA 108 0 0 0 GAMr% 3 0 3 0 MILK GAMMA 33 0 33 0 IODINE 7 2 7 2 0 0 0 0 _., STRONTIUM WATER GROSS ALPHA 0 0 0 0 GAMMA 17 1 64 0 GROSS BETA 0 0 0 0 0 0 0 0 STRONTIUM TRITIUM 3 0 3 0 SOIL / SEDIMENT l GAMMA 0 0 46 0 j VEGITATION I GAMMA 2 TOTAL 224 3 158 2 l 81 a
TABLE 4.2
SUMMARY
OF EPA INTERCOMPARISON RESULTS JANUARY - DECEMBER 1998 li EPA DESL CONTROL EPA REF. SAMPLE TYPE NUCLIDE MEAN LIMIT RANGE DATE (pCi/1) (pC1/1) 01/16/98 WATER Sr-90 28.4 23.3-40.7 01/30/98 Alpha 9.8 9 17.3-43.7 Beta 7.3 0-1J.7 02/06/98 I-131LL 108.9 86.7-123.1 02/13/98 Ra-226 16.8 11.8-20.2 Ra-228 33.7 18.9-47.7 Nat.U 28.9 26.8-37.2 H-3 2095 1551-2759 04/21/98 Sr-90 15.5 9.3-26.7 Co-60 48.2 41.3-58.7 CS-134 21.2 13.3-30.7 Cs-137 9.1 1.3-18.7 Ra-226 17.4 11-19 Ra-228 9.0 5.3-13.3 Nat. U 4.1 0-10.2 06/05/98 Cs-134 27.9 22.3-39.7 Cs-137 35.1 26.3-43.7 Zn-65 103.9 86.7-121.3 Co-60 11.8 3.3-20.7 Ba-133 37.6 31.3-48.7 06/12/98 Nat. U 3.4 0-8.2 Ra-226 4.7 3.7-6.1 Ra-228 2.4 1,2-3.0 07/17/98 Sr-89 20.8 12.3-29.7 Sr-90 8.1 0-15.7 82
l l TABLE 4.2 (Cont.)
SUMMARY
OF EPA INTERCOMPARISON RESULTS j JANUARY - DECEifBER 1998 l 1 UESEL EPA i EPA Ref. SAMPLE NUCLTDE MEAN Control Date TYPE (pci/1) Limits (pci/1) 07/24/98 Water Beta 13.5 4.5-23.4
)
Alpha 5.4 0-15.9 08/07/98 H-3 17551 14873-21119 09/11/96 I-131 LL 5.6 2.6-9.6 09/18/98 Ra-226 1.7 1.2-2.2 Ra-228 6.2 3.3-8.1 Nat. U 8.5 3.9-14.3
# Non-Agreement d
l > l l l
)
83 ) I
TABLE 4.3 DESEL 1998 ANALYTICS CROSS-CHECK RESULTS FIRST QUARTER 1998 - MILK NUCLIDE REPORTED VALUE KNOWN VALUE DESEL/ANALYTICS l EVALUATION Cr-51 204 201 1.01 AGREEMENT Mn-54 139 133 1.05 AGREEMENT , Fe-59 100 95 1.05 AGREEMENT l Co-60 86 85 1.01 AGREEMENT Zn-65 147 142- 1.04 AGREEMENT Sr-89 55 53 1.04 AGREEMENT S1-90 45 44 1.02 AGREEMENT I-131 84 82 1.02 AGREEMENT 7-131LL 83 82 1.01 AGREEMENT Cs-134 83 84 0.99 AGREEMENT Cs-137 171 161 1.04 AGREEMENT Ce-141 73 70 1.04 AGREEMENT FIRST QUARTER 1998 -WATER NUCLIDE REPORTED VALUE KNOWN VALUE DESEL/ANALYTICS EVALUATION ALPHA 42 38 1.11 AGREEMENT BETA 308 269 1.14 AGREEMENT Cr-51 171 167 1.02 AGREEMENT Mn-54 111 111 1.00 AGREEMENT Cr-51 171 167 1.02 AGREEMENT Fe-59 82 79 1.04 AGREEMENT Co-60 70 71 0.99 AGREEMENT Zn-65 120 13 8 1.02 AGREEMENT I-131 90 90 1.00 AGREEMENT Cs-134 68 70 0.97 AGREEMENT Cs-137 136 134 1.01 AGREEMENT Ce-141 59 58 1.02 AGREEMENT Ra-226 56 53 1.06 AGREEMENT Ra-228 47 46 1.02 AGREEMENT U-234 .l') 29 1.03 AGREEMENT I-131 LL 02 90 1.02 AGREEMENT Pu-238 72 75 0.96 AGREEENT Pu-240 43 42 1.02 AGREEMENT U-238 31 30 1.03 AGREEMENT 84
l I TABLE 4.3 (CONT.) SECOND QUARTER 1998 - AIR FILTER NUCLIDE REPORTED VALUE KNOWN VALUE DESEL/ANALYTICS EVALUATION ALPHA 36 36 1.00 AGREEMENT BETA 220 212 1.O4 AGREEMENT Cr-51 111 113 0.98 AGREEMENT Mn-54 96 91 1.05 AGREEMENT l Fe-59 43 39 1.10 AGREEMENT l Co-60 116 124 0.94 AGREEMENT Zn-65 114 105 1.09 AGREEMENT Sr-89 140 142 0.99 AGREEMENT Sr-90 49 51 0.96 AGREEMENT Cs-134 84 82 1.02 AGREEMENT Cs-137 62 61 1.02 AGREEMENT Ce-141 80 85 0.94 AGREEMENT l l SECOND QUARTER 1998 - MILK & WATER NUCLIDE REPORTED VALUE KNOWN VALUE DESEL/ANALYTICS EVALUATION H-3 5697 6007 0.95 AGREEMENT I I-131LL 67 67 1.O AGREEMENT Cr-51 128 132 0.97 AGREEMENT Mn-54 111 106 1.05 AGREEMENT Fe-59 46 45 1.02 AGREEMENT Co-60 144 143 1.01 AGREEMENT Zn-65 124 122 1.02 AGREEMENT I-131 71 67 1.06 AGREEMENT Cs-134 97 95 1.02 AGREEMENT Cs-137 74 70 1.06 AGREEMENT Ce-141 102 99 1.03 AGREEMENT 85
l l l TABLE 4.3 (CONT.) THIRD QUARTER 1998 - MILK NUCLIDE REPORTED VALUE KNOWN VALUE I DESEL/ANALYTICS EVALUATION l l Cr-51 180 186 0.97 AGREEMENT Mn-54 77 74 1.04 AGREEMENT Fe-59 66 63 1.05 AGREEMENT Co-60 146 148 l 0.99 AGREEMENT Zn-65 201 195 1.03 AGREEMENT Sr-89 62 51 1.22 AGREEMENT Sr-90 72 81 0.89 AGREEMENT I-131 96 90 1.07 AGREEMENT Cs-134 80 82 0.98 AGREEMENT Cs-137 134 134 1.0 AGREEMENT I-131LL 87 90 0.97 AGREEMENT
- Ce-141 145 146 0.99 AGREEMENT THIRD QUARTER 1998 - WATER NUCLIDE REPORTED VALUE KNOWN VALUE DESEL/ANALYTICS EVALUATION l
ALPHA 61 66 0.92 AGREEMENT BETA 190 198 0.96 AGREEMENT Cr-51 172 165 1.04 AGREEMENT Mn-54 66 66 1.0 AGREEMENT i Fe-59 59 55 1.07 AGREEMENT Co-60 129 131 0.98 AGREEMENT Zn-65 175 173 1.01 AGREEMENT Sr-89 83 84 0.99 AGREEMENT Sr-90 47 51 0.92 AGREEMENT I-131 82 79 1.04 AGREEMENT Cs-134 71 73 0.97 AGREEMENT Cs-137 117 119 0.98 AGREEMENT I-131LL 78 79 0.99 AGREEMENT
- Ce-141 129 129 1.0 AGREEMENT
- Accuracy within agreement criteria, but precision result contributed to CR98-009 86
TABLE 4.4
SUMMARY
OF BLIND DUPLICATE SAMPLES SUBMITTED JANUARY - DECEMBER 1998 l TYPE OF SAMPLE NUMBER OF PAIRED SAMPLES SUBMITTED MILK 26 GROUND WATER 8 SURFACE WATER 16 ALGAE 2 MUSSELS 4 FOOD CROP 1 1 TOTAL 57 l 87
TABLE 4.5
SUMMARY
OF BLIND DUPLICATE RESULTS January - December 1988 , TOTAL ANALYSIS ! ANALYSIS TYPE MILK WATER FOOD PROD HARINE MUSSEL TOTAL ALGAE GAMMA 650(4) 600(2) 25 50 100 1425(6) Sr-P.9,90 16 - - - - 16 h' 3 - 13 - - - 13 Gross Beta - 12 - - - 12 Ra-226/228 - - - - - - I-131 22 4 - - - 26
- The number of paired measurements that did not meet the acceptance criteria is given in parentheses, i
J l
+
i i i
~
88
r i-5.0 Land Use census l f Technical Specification 4.12.2 requires that a Land Use census be conducted annually. The 1998 census was completed in accordance with the requirements of the ODCM. The census is used to identify the location of the nearest milk animal, the nearest residence, and the nearest garden of 50 square meters within five miles of plant. In 1998, A global positioning system was used. The distance from the plant for : each of the above locations is shown in Table 5.1. f l l l l 89 L
l Table 5.1 Land Use Census Results Nearast Nearest Nearest Residence Garden Wilk Animal Sector (km) (km) (km) N 1.0 4.2 NNE 3.2 3.2 NE 2.4 3.2 ENE 2.4 E 2.6 ESE 2.4 SE 2.4 SSE 1.0 1.0 3 1.0 1.1 SSW 0.8 0.8 SW 1.0 5.2 WSW 1.0 1.0 W 1.0 1.0 WNW 1.0 1.1 4.8 NW 1.0 1.1 7.1 NNW 1.1 1.1 5.5 90
ATTACHMENT I Sample Analysis Data A
I Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program Summary of 1998 Data l l SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) l Irish Moss AL 05 42290 05/18/98 Ag-110M -1.41E+01 9.43E+00 4.01E+01 AL 05 42290 05/18/98 Ba-140 1.63E+01 1.76E+01 6.39E+01 AL 05 42290 05/18/98 Be-7 3.50E+02 9.02E+01 2.56E+02
- AL 05 42290 05/18/98 Ce-141 5.32E+00 1.02E+01 3.31E+01 l
AL 05 42290 05/18/98 Ce-144 1.36Es01 2.33E+01 7.52E+01 AL 05 42290 05/18/98 Co-57 2.80E+00 3.50E+00 1.10E+01 AL 05 42290 05/18/98 Co-58 7.88E+00 7.27E+00 2.37E+01 AL 05 42290 05/18/98 Co-60 -2.33E+00 6.67E+00 2.70E+01 ! AL 05 42290 05/18/98 Cr-51 -1.76E+01 7.39E+01 2.68E+02 AL 05 42290 05/18/98 Cs-134 -5.16E+00 5.18E+00 2.03E+01 AL 05 41290 05/18/98 Cs-137 2.62E+00 6.14E+00 2.28E+01 AL 05 42290 05/18/98 Fe-59 2.53E+00 2.66E+01 9.85E+01 AL 05 42290 05/18/98 I-131 2.83E+01 3.91E+01 1.33E+02 I AL 05 42290 05/18/98 K-40 6.58E+03 3.69E+02 3.59E+02
- I AL 05 42290 05/18/98 Mn-54 1.02E+01 6.15E+00 1.86E+01 AL 05 42290 05/18/98 Ru-103 -7.61E+00 5.56E+00 2.46E+01 l AL 05 42290 05/18/98 Ru-106 -1.24E+02 5.42E+01 2.48E+02 l AL 05 42290 05/18/98 Sb-124 -6.25E+00 5.93E+00 4.45E+01 AL 05 42290 05/18/98 Se-75 -8.26E+00 5.81E+00 2.33E+01 AL 05 42290 05/18/98 Th-232 7.48E+01 3.19E+01 9.43E+01 AL 05 42290 05/18/98 Zn-65 2.15E+01 1.82E+01 6.04E+01 AL 05 42290 05/18/98 Zr-95 1.45E+00 1.26E+01 4.56E+01 AL 05 45730 11/16/98 Ag-110M -9.48E+00 1.38E+01 5.96E+01 AL 05 45730 11/16/98 Ba-140 -3.39E+01 2.39E+01 1.69E+02 AL 05 45730 11/16/98 Be-7 1.54E+02 8.58E+01 2.55E+02 AL 05 45730 11/16/98 Ce-141 3.89E+00 1.25E+01 4.21E+01 AL 05 45730 11/16/98 Ce-144 3.79E+01 3.96E+01 1.24E+02 AL 05 45730 11/16/98 Co-57 -6.24E+00 4.85E+00 1.78E+01 AL 05 45730 11/16/98 Co-58 -0.96E+00 1.14E+01 4.56E+01 AL 05 45730 11/16/98 Co-60 4.80E+00 1.27E+01 5.16E+01 AL 05 45730 11/16/98 Cr-51 -1.51E+02 1.01E+02 4.33E+02 AL 05 45730 11/16/98 Cs-134 -2.33E+00 7.09E+00 3.06E+01 AL 05 45730 11/16/98 Cs-137 1.90E+01 8.70E+00 2.30E+01 AL 05 45730 11/16/98 Fe-59 -4.93E+01 5.98E+01 2 53E+02 AL 05 45730 11/16/98 I-131 -9.08E+01 6.35E+01 2.76E+02 AL 05 45730 11/16/98 K-40 7.30E+03 6.16E+02 6.59E+02
- AL 05 45730 11/16/98 Mn-54 -3.21E+00 6.62E+00 3.11E+01 AL 05 45730 11/16/98 Ru-103 7.10E+00 1.17E+01 4.25E+01 AL 05 45730 11/16/98 Ru-106 4.89E+01 9.15E+01 3.45E+02 AL 05 45730 11/16/98 Sb-124 1.65E+01 2.81E+01 1.17E+02 AL 05 45730 11/16/98 Se-75 4.33E400 1.12E+01 3.91E+01 AL 05 45730 11/16/98 Th-232 7.13E+01 4.64E+01 1.46E+02 AL 05 45730 11/16/98 Zn-65 2.68E+01 2.97E+01 1.04E+02 AL 05 45730 11/16/98 Zr-95 1.32E+01 2.34E+01 8.31E+01 l
l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) AL 55 42292 05/18/98 Ag-110M -1.84E+01 1.70E+01 7.02E+01 AL 55 42292 05/18/98 Ba-140 2.63E+01 2.37E+01 8.11E+01 AL 55 42292 05/18/98 Be-7 3.14E+02 1.68E+02 5.60E+02 AL 55 42292 05/18/98 Ce-141 5.22E+01 1.87E+01 5.12E+01 AL 55 42292 05/18/98 Ce-144 1.59E+01 5.83E+01 1.87E+02 AL 55 42292 05/18/98 Co-57 8.02E+00 7.54E+00 2.31E+01 AL 55 42292 05/18/98 Co-58 -3.65E+00 1.42E+01 5.36E+01 AL 55 42292 05/18/98 Co-60 -6.51E+00 9.77E+00 4.71E+01 AL 55 42292 05/18/98 Cr-51 -8.78E+01 1.32E+02 4.87E+02 AL 55 42292 05/18/98 Cs-134 1.47E+01 1.04E+01 3.10E+01 AL 55 42292 05/18/98 Cs-137 2.11E+01 1.16E+01 3.62E+01 AL 55 42292 05/18/98 Fe-59 1.61E+00 4.96E+01 1.92E+02 AL 55 42292 05/18/98 I-131 2.27E+01 4.93E+01 1.71E+02 AL 55 42292 05/18/98 K-40 5.66E+03 5.37E+02 8.26E+02
- AL 55 42292 05/18/98 Mn-54 -1.55E+01 1.12E+01 4.79E+01 AL 55 42292 05/18/98 Ru-103 1.61E+01 1.32E+01 4.31E+01 AL 55 42292 05/18/98 Ru-106 -2.00E+01 7.60E+01 3.22E+02 AL 55 42292 05/18/98 Sb-124 -1.61E+01 2.87E+01 1.36E+02 AL 55 42292 05/18/98 Se-75 2.90E+00 1.26E+01 4.41E+01
- AL 55 42292 05/18/98 Th-232 0.00E+00 4.92E+01 1.83E+02 AL 55 42292 05/18/98 Zn-65 -6.10E+00 3.04E+01 1.14E+02 AL 55 42292 05/18/98 Zr-95 -2.48E+01 2.17E+01 9.68E+01 AL 55 45732 11/16/98 Ag-110M -8.40E+00 1.03E+01 4.73E+01 AL 55 45732 11/16/98 Ba-140 -1.08E+02 4.36E+01 2.31E+02 AL 35 45732 11/16/98 Be-7 5.34E+00 1.17E+02 4.21E+02 AL 55 45732 11/16/98 Ce-141 -1.68E+01 1.75E+01 6.36E+01 AL 55 45732 11/16/98 Ce-144 -8.31E+01 4.07E+01 1.57E+02 AL 55 45732 11/16/98 Co-57 -5.09E+00 5.41E+00 1.93E+01 1 AL 55 45732 11/16/98 Co-58 -1.38E+01 1.34E+01 5.36E+01 AL 55 45732 11/16/98 Co-60 1.05E+01 1.12E+01 3.87E+01 AL 55 45732 11/16/98 Cr-51 -1.31E+02 1.27E+02 4.95E+02 AL 55 45732 11/16/98 Cs-134 5.40E+00 9.29E+00 3.18E+01 AL 55 45732 11/16/98 Cs-137 -1.79E+00 1.13E+01 4.40E+01 ! AL 55 45732 11/16/98 Fe-59 7.02E+01 4.58E+01 1.42E+02 ) AL 55 45732 11/16/98 I-131 7.71E+01 7.47E+01 2.49E+02 ] AL 55 45732 11/16/98 K-40 7.15E+03 5.25E+02 6.31E+02
- j AL 55 45732 11/16/98 Mn-54 1.28E+00 9.42E+00 3.51E+01 AL 55 45732 11/16/98 Ru-103 -2.58E+01 1.23E+01 5.48E+01 AL 55 45732 11/16/98 Ru-106 -1.95E+03 9.50E+01 4.31E+02 ,
AL 55 45732 11/16/98 Sb-124 3.47E+01 2.56E+01 8.25E+01 l AL 55 45732 11/16/98 Se-75 1.19E+01 1.28E+01 4.26E+01 ; AL 55 45732 11/16/98 Th-232 1.28E+01 4.31E+01 1.58E+02 i AL 55 45732 11/16/98 Zn-65 6.34E+01 5.74E+01 2.13E+02 l AL 55 45732 11/16/98 Zr-95 -2.38E+00 2.15E+01 8.08E+01 l l l
- Radiosctivity detected in sample (i.e., CONC > 3 STD. DEV.)
I I i J
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data
. SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) . (pCi/cu.m)
Air Particulates AP 01 40292 01/07/98 GR-B 1.63E-02 1.51E-03 3.91E-03
- AP 01 40367 01/14/98 GR-B 1.37E-02 1.52E-03 4.05E-03
- AP 01 40532 01/21/98 GR-B 1.11E-02 1.50E-03 4.18E-03
- AP 01 40621 01/28/98 GR-B 1.91E-02 1.42E-03 3.27E-03'*
AP 01 40692 02/04/98 GR-B 2.12E-02 1.65E-03 4.05E-03
- AP- 01 40858 02/11/98 GR-B 2.48E-02 1.69E-03 3.93E-03
- AP 01 40926 02/18/98 GR-B 1.81E-02 1.60E-03 4.18E-03
- l AP 01 41038 02/25/98 GR-B 5.25E-03 1.38E-03 4.05E-03
- AP 01 41215 03/04/98 GR-B 1.01E-02 1.53E-03 4.22E-03
- AP 01 41297 03/11/98 GR-B 9.55E-03 1.50E-03 4.03E-03
- AP 01 41410 03/18/98 GR-B 2.49E-02 1.73E-03 4.12E-03
- AP 01 41508 03/25/98 GR-B 1.42E-02 1.56E-03 4.19E-03
- AP 01 41577 04/01/98 GR-B 2.07E-02 1.68E-03 4.26E-03
- AP 01 41617 04/08/98 GR-B 1.31E-02 1.55E-03 4.04E-03
- AP 01 41819 04/15/98 GR-B 2.11E-02 1.52E-03 3.43E-03
- AP 01 41961 04/22/98 GR-B 1.84E-02 1.43E-03 3.36E-03
- AP 01 41988 04/29/98 GR-B 1.16E-02 1.35E-03 3.58E-03
- AP 01 42127 05/06/98 GR-B 1.69E-02 1.51E-03 3.59E-03
- AP Ol' 42219 05/12/98 GR-B 1.09E-02 1.79E-03 4.90E-03
- AP 01 42336 05/20/98 'GR-B 1.73E-02 1.31E-03 2.99E-03
- AP 01 42429 05/27/98 GR-B 2.01E-02 1.75E-03 4.34E-03
- AP 01 42539 06/03/98 GR-B 1.71E-02 1.58E-03 3.99E-03
- AP 10 1 42617 06/10/98 GR-B 1.07E-02 1.47E-03 4.07E-03
- AP 01 42716 06/17/98 GR-B 1.66E-02 1.54E-03 3.94E-03
- AP 01 42788 06/24/98 GR-B 1.04E-02 1.35E-03 3.75E-03
- AP 01 42906 07/01/98 GR-B 1.31E-02 1.60E-03 4.26E-03
- AP 01 42996 07/08/98 GR-B 1.07E-02 1.41E-03 3.84E-03
- AP 01 43074 07/15/98 GR-B 1.45E-02 1.66E-03 4.33E-03
- AP 01 43165 07/22/98 GR-B 2.52E-02 1.74E-03 4.18E-03
- AP 01 43308 07/29/98 GR-B 1.60E-02 1.58E-03 4.16E-03
- AP 01 43381 08/05/98 GR-B 1.69E-02 1.69E-03 4.33E-03
- AP 01 43513 08/12/98 GR-B 2.12E-02 1.66E-03 4.11E-03
- AP 01 43647 08/19/98 GR-B 9.24E-03 1.58E-03 4.38E-03
- AP 01 43874 08/26/98 GR-B 2.39E-02 1.61E-03 3.53E-03
- AP 01 44069 09/02/98 GR-B 2.18E-02 1.70E-03 4.07E-03
- AP 01 44165 09/09/98 GR-B 1.83E-02 1.67E-03 4.21E-03
- AP 01 44268 09/16/98 GR-B 1.47E-02 1.45E-03 3.74E-03
- AP 01 44354 09/23/98 GR-B 1.82E-02 1.73E-03 4.42E-03
- AP 01 44659 09/30/98 GR-B 2.29E-02 1.57E-03 3.54E-03 *
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
(- l { l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m (pCi/cu.m ),(pCi/cu.m)
.....__________________________________________________) _________________________
AP 01 45075 10/07/98 GR-B AP 1.34E-02 1.37E-03 3.53E-03
- 01 45099 10/14/98 GR-B 7.03E-03 AP 01 1.57E-03 4. 55E-03
- 45279 10/21/98 GR-B 1.97E-02 1.73E-03 4.45E-03
- AP 01 45413 10/28/98 GR-B 1.80E-02 1.49E-03 3.62E-03
- AP 01 45507 11/04/98 GR-B AP 7.58E-03 1.58E-03 4.44E-03
- 01 45689 11/10/98 GR-B 1.00E-02 AP 01 1.49E-03 4.00E-0J*
- 45719 11/18/98 GR-B 2.43E-02 1.48E-03 3.32E-03
- AP 01 45869 11/25/98 GR-B 2.06E-02 1.71E-03 4.25E-03
- AP 01 46111 12/02/98 AP GR-B 2.08E-02 1.60E-03 3.71E-03
- 01 46180 12/09/98 GR-B 2.17E-02 AP 01 1.61E-93 3.82E-03
- 46127 12/16/98 GR-B 2.54E-02 1.83E-03 4.34E-03
- AP 01 46525 12/23/98 GR-B AP 1.87E-02 1.63E-03 4.06E-03
- 01 46590 12/29/98 GR-B 3.97E-02 2.27E-03 5.38E-03
- l I
l I i I I i 4 i-
. l \
l l l l l i I l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
J
I 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN ZND DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) (pCi/cu.m) AP 02 40293 01/07/98 GR-B 2.21E-02 1.82E-03 4.57E-03
- AP 02 40368 01/14/98 GR-B 1.51E-02 1.80E-03 4.75E-03
- AP 02 40533 01/21/98 GR-B 1.32E-02 1.80E-03 4.97E-03
- l AP 02 40622 01/28/98 GR-B 2.35E-02 1.66E-03 3.81E-03
- i AP 02 40693 02/04/98 GR-B 2.39E-02 1.97E-03 4.80E-03
- AP 02 40859 02/11/98 GR-B 2.80E-02 1.96E-03 4.66E-03
- AP. 02 40927 02/18/98 GR-B 1.67E-02 1.83E-03 4.93E-03
- j AP 02 41039 02/25/98 GR-B 8.34E-03 1.67E-03 4.85E-03
- l 1
AP 02 41216 03/04/98 GR-B 1.04E-02 1.87E-03 5.45E-03
- i AP 02 41298 03/11/98 GR-B 1.21E-02 1.80E-03 4.88E-03
- AP 02 41411 C3/18/98 GR-B 2.69E-02 1.99E-03 4.87E-03 * !
AP 02 41509 03/25/98 GR-B 1.53E-02 1.84E-03 5.06E-03
- AP 02 41578 04/01/98 GR-B 2.59E-02 1.79E-03 4.42E-03 * !
AP 02 41618 04/08/98 GR-B 1.23E-02 1.61E-03 4.19E-03
- 41820 04/15/98 AP 02 GR-B 2.50E-02 1.62E-03 3.60E-03 * {
AP 02 41962 04/22/98 GR-B 1.71E-02 1.46E-03 3.54E-03
- i AP 02 41989 04/29/98 GR-B 1.66E-02 1.52E-03 3.76E-03 * !
l AP 02 42128 05/06/98 GR-B 1.45E-02 1.45E-03 3.58E-03
- l AP 02 42220 05/13/98 GR-B 8.62E-03 1.57E-03 4.42E-03 *' j AP 02 42337 05/20/98 GR-B 1.53E-02 1.39E-03 3.40E-03
- i AP 02 42430 05/27/98 GR-B 1.94E-02 1.81E-03 4.59E-03
- I AP 02 42540 06/03/98 GR-B 2.11E-02 1.69E-03 4.17E-03 * ,
AP 02 42618 06/10/98' GR-B 9.03E-03 1.49E-03 4.18E-03 * ! AP 02 42717 06/17/98 GR-B 1.65E-02 1.61E-03 4.18E-03 * - AP 02 42789 06/24/98 GR-B 1.15E-02 1.d4E-03 3.97E-03
- AP 02 42907 07/01/98 GR-B 1.55E-02 1.73E-03 4.56E-03
- AP 02 42997 07/08/98 GR-B 1.00E-02 1.52E-03 4.16E-03
- AP 02' 43075 07/15/98 GR-B 1.60E-02 1.83E-03 4.66E-03
- AP 02 43166 07/22/98 GR-B 2.75E-02 1.90E-03 '4.52E-03 * !
AP 02 43309 07/29/98 GR-B 1.54E-02 1.65E-03 4.45E-03
- l AP 02 43382 08/05/98 GR-B 1.83E-02 1.81E-03 4.61E-03
- i AP 02 43514 08/12/98 GR-B 2.18E-02 1.71E-03 4.28E-03
- i AP 02 43648 08/19/98 GR-B 1.18E-02 1.71E-03 4.67E-03
- l AP 02 43875 08/26/98 GR-B 2.50E-02 1.69E-03 3.77E-03
- AP 02 44070 09/03/98 GR-B 2.20E-02 1.65E-03 3.99E-03
- AP 02' 44166 09/09/98 GR-B 2.90E-02 2.17E-03 5.30E-03 * !
AP 02 44269 09/16/98 GR-B 1.73E-02 1.58E-03 3.96E-03
- AP 02 44355 09/23/98 GR-B 2.04E-02 1.80E-03 4.68E-03
- AP 02 44660 09/30/98 GR-B 2.46E-02 1.62E-03 3.68E-03 *
- Radioactivity detected in sample (i . e . , CONC > 3 STD. DEV. )
l
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) l (pCi/cu.m ) , (pCi/cu.m) l AP: '02 45076 10/07/98 GR-B 1.54E-02 AP 1.42E-03 3.65E-03
- 02 45100 10/14/98 GR-B 8.61E-03 1.61E-03 AP 4.70E-03
- l 02 45280 10/21/98 GR-B 2.15E-02 1.79E-03 4.61E-03
- l AP 02 45414 10/28/98 GR-B 1.97E-02 1.53E-03 3.70E-03
- AP 02 45608 11/04/98 GR-B 1.05E-02 AP 1.71E-03 4.60E-03
- 02 45690 11/10/98 GR-B 9.33E-03 1.47E-03 4.03E-03
- AP 10 2 45720 11/1c/98 GR-B 2.645-02 1.53E-03 3.40E-03
- AP 02 45870 11/25/98 GR-B 2 . 3 t:E-02 .1.79E-03 4.32E-03
- AP- 02 46112 12/02/98 GR-B 1.81E-02 AP 1.57E-03 3.80E-03
- 02 46191 12/09/98 GR-B 2.80E-02 1.79E-03 3.94E-03
- AP 02 46128 12/16/98 GR-B 2.44E-02 1.81E-03 4.35E AT
- AP 02 46526 12/23/98 C3-B 1.87E-02 AP 02
- 1. 67 E'- 0.3 4.14E-c3
- 46591 12/29/98 GR-B 4.00E-02 2.27E-03 5.29E-03
- 1 1
i l I l l I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i l i Seabrook Nuclear Power Station ( Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC ! TYPE STA. LSN END DATE 'NUCLIDE (pCi/cu.m) (pCi/cu.m ) , (pCi/cu.m) AP 03 40294 01/07/98 GR-B 1.91E-02 1.66E-03 4.26E-03
- l AP 03 40369 01/14/98 GR-B 1.53E-02 1.60E-03 4.30E-03 * !
AP 03- 40534 01/21/98 GR-B 1.34E-02 1.66E-03 4.58E-03
- l AP 03 40623 01/28/98 GR-B 2.08E-02 1.54E-03 3.52E-03 * :
AP 03 40694 02/04/98 GR-B 2.02E-02 1.75E-03 4.43E-03 * ' AP 03 40860 02/11/98 GR-B 2.81E-02 1.86E-03 4.34E-03 * ( AP 03 40928 02/18/98 GR-B 1.74E-02 1.77E-03 4.60E-03
- l AP 0
'3 41040 02/25/98 GR-B 6.82E-03 1.50E-03 4.41E-03 * ,
AP 03 I 41217 03/04/98 GR-B 6.03E-03 1.62E-03 4.93E-03
- l AP 03 41299 03/11/98 GR-B 1.20E-02 1.67E-03 4.45E-03
- AP 03 41412 03/18/98 )
GR-B 2.60E-02 1.88E-03 4.55E-03
- j AP 03 41510 03/25/98 GR-B 1.80E-02 1.79E-03 4.83E-03
- j AP 03 41579 04/01/98 GR-B 3.11E-02 2.07E-03 5.08E-03
- l AP 03 41619 04/08/98 GR-B 8.46E-03 1.49E-03 3.86E-03 * )
AP 03 41821 04/15/98 GR-B 2.56E-02 1.63E-03 3.46E-03 * ! AP 03 41963 04/22/98 GR-B 2.06E-02 1.42E-03 3.30E-03 * { AP 03 41990 04/29/98 GR-B 1.19E-02 1.37E-03 3.67E-03
- AP 03 42129 05/06/98 GR-B 1.44E-02 1.40E-03 3.32E-03
- AP' 03 42221 05/12/98 GR-B 8.12E-03 1.64E-03 4.55E-03 *'
AP 03 42338 05/20/98 GR-B 1.70E-02 1.54E-03 3.73E-03
- 4 AP 03 42431 05/27/98 GR-B 2.30E-02 2.05E-03 5.12E-03
- I AP 03 42541 06/03/98 GR-B 2.61E-02 1.99E-03 4.78E-03
- AP 03 42619 06/10/98 GR-E 1.05E-02 1.68E-03 4.59E-03
- AP 03 42718 '06/17/98 GR-B 1.94E-02 1.79E-03 4.58E-03
- AP <
03 42790 06/24/98 GR-B 1.33E-02 1.62E-03 4.40E-03
- AP 03 42908 07/01/98 GR-B 1.62E-02 1.83E-03 4.86E-03
- AP 03 42998 07/08/98 Gh-B 1.06E-02 1.67E-03 4.68E-03
- AP 03 43076 07/15/96 GR-B 1.63E-02 2.13E-03 5.38E-03
- AP 03 43167 07/22/98 GR-B 3.46E-02 2.12E-03 '4 93E-03
- AP 03 43510 07/29/98 GR-B 1.68E-02 1.90E-03 5.16E-03
- AP 03 43383 08/05/98 GR-B 2.00E-02 1.96E-03 5.12E-03
- AP. 03 43515 08/12/98 GR-B 2.94E-02 2.09E-03 5.07E-03
- AP 03 43649 08/19/98 GR-B 1.36E-02 1.89E-03 5.21E-03
- AP 03 43876 08/26/98 GR-B 2.58E-02 1.94E-03 4.43E-03 *
' AP 00 44071 09/02/98 GR-B 2.84E-02 2.11E-03 5.11E-03
- AP 03 44167 09/09/S8 GR-B 2.79E-02 2.11E-03 5.24E-03
- AP 03 44270 09/16/98 GR-B 1.94E-02 1.77E-03 4.45E-03 * ,
AP 03 ~ 44356 09/23/98 GR-B 2.22E-02 2.08E-03 5.45E-03
- l AP 03 44661 09/30/98 GR-B 2.93E-02 1.77E-03 3.80E-03
- l 1
P
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE- STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) (pC1/cu.m) AP 03 45077 10/07/98 GR-B 1.92E-02 1.58E-03 3.89E-03
- AP 03 45101 10/14/98 GR-B 8.00E-03 1.69E-03 4.93E-03
- AP 03 45281 10/21/98 GR-B 1.82E-02 1.93E-03 5.02E-03
- AP .03 45415 10/28/98 GR-B 2.07E-02 1.71E-03 4.18E-03
- AP 03 45509 11/04/98 GR-B 1.06E-02 1.82E-03 4.94E-03
- AP 03 45691 11/10/98 GR-B 1.23E-02 1.67E-03 4.37E-03
- AP 03 45721 11/18/98 GR-B 2.75E-02 1.66E-03 3.72E-03
- AP 03 45871 11/25/98 GR-B 2.82E-02 2.08E-03 4.99E-03
- AP 03 46113 12/02/98 GR-B 2.78E-02 1.93E-03 4.30E-03
- AP 03 46182 12/09/98 GR-B 3.64E-02 2.02E-03 4.26E-03
- AP 03 46129 12/16/98 GR-B 3.44E-02 2.04E-03 4.61E-03 * >
AP 03 46527 12/23/98 GR-B 2.34E-02 1.86E-03 4.46E-03
- AP 03 46592 12/30/98 GR-B 3.81E-02 2.09E-03 4.92E-03
- l I
l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Swmmary of 1998 Data " SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) __.__________________________________________________________________,(pCi/cu.m) ___________ AP 04 40295 01/07/98 GR-B 1.68E-02 AP 1.46E-03 3.76E-03
- 04 40370 01/14/98 GR-B 1.28E-02 1.42E-03 3.83E-03
- AP 04 40535 01/21/98 GR-B 1.18E-02 1.51E-03 4.08E-03
- AP 04 40624 01/28/98 GR-B 2.14E-02 1.44E-03 3.17E-03
- A.' 04 40695 02/04/98 GR-B 2.07E-02 AP 1.62E-03 3.91E-03
- 04 40861 02/11/98 GR-B 2.46E-02 1.63E-03 3.85E-03
- AP 04 40929 02/18/98 GR-B 1.63E-02 AP 1.58E-03 4.04E-03
- 04 41041 02/25/98 GR-B 8.85E-03 1.42E-03 4.04E-03
- AP 04 41218 03/04/98 GR-B 7.85E-03 AP 1.51E-03 4.51E-0 04 41300 03/11/98 GR-B 1.10E-02 AP 1.49E-03 4.02E 04 41413 03/18/98 GR-B 2.49E-02 1.77E-03 4.15E-03
- AP 04 41511 03/25/98 GR-B 1.74E-02 1.58E-03 4.17E-03
- AP 04 41580 04/01/98 GR-B 2.53E-02 AP 1.78E-03 4.40E-03
- 04 41620 04/08/98 GR-B 1.13E-02 1.43E-03 3.76E-03
- AP 04 41822 04/15/98 GR-B 2.48E-02 AP 1.57E-03 3.32E-03
- 04 41964 04/22/98 GR-B 1.76E-02 1.37E-03 3.17E-03
- AP 04 41991 04/29/98 GR-B 1.44E-02 1.40E-03 3.52E-03
- AP 04 42130' 05/06/98 GR-B 1.70E-02 AP 1.38E-03 3.18E-03
- 04 42222 05/13/98 GR-B 9.73E-03 1.48E-03 4.12E-03
- AP 04 42339 05/20/98 GR-B 1.82E-02 AP 1.39E-03 3.21E-03
- 04 42432 05/27/98 GR-B 1.80E-02 1.74E-03 4.33E-03 *
- l AP 04 42542 06/03/98 GR-B 2.46E-02 AP 1.76E-03 4.07E-03
- 04 42620 06/10/98 GR-B 1.03E-02 1.41E-03 3.92E-03
- AP 04 42719 06/17/98 GR-B 1.76E-02 AP 1.57E-03 3.91E-03
- 04 42791 06/24/98 GR-B 1.26E-02 1.42E-03 3.81E-03
- AP 04 42909 07/01/98 GR-B 1.55E-02 AP 1.59E-03 4.15E-03
- 04 42999 07/08/98 GR-B 9.26E-03 1.46E-03 3.95E-03
- AP 04 43077 07/15/98 GR-B 1.45E-02 AP 1.72E-03 4.52E-03
- 04 43168 07/22/98 GR-B 2.82E-02 1.89E-03 '4.58E-03
- AP 04 43311 07/29/98 GR-B 1.58E-02 1.64E-03 4.38E-03
- AP 04 43384 08/05/98 GR-B 1.97E-02 AP 1.73E-03 4.35E-03
- 04 43516 08/12/98 GR-B 2.43E-02 1.75E-03 4.30E-03
- AP 04 43650 08/19/98 GR-B 1.32E-02 AP 1.65E-03 4.45E-03
- 04 43877 08/26/98 GR-B 2.35E-02 1.64E-03 3.73E-03
- AP 04 44072 09/02/98 GR-B 2.18E-02 1.75E-03 4.19E-03
- AP 04 44168 09/09/98 GR-B 2.30E-02 AP 1.86E-03 4.63E-03
- 04 44271 09/16/98 GR-B 1.73E-02 AP 1.55E-03 3.88E-03
- 04 44357 09/23/98 GR-B 2.13E-02 1.83E-03 4.73E-03
- AP 04 44662 09/30/98 GR-B 2.51E-02 1.61E-03 3.61E-03 *
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
l
. Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data
. SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) (pCi/cu.m) AP 04 45078 10/07/98 GR-B 1.64E-02 1.46E_03 3.65E-03
- AP 04 45102 10/14/98 GR-B 8.35E-03 1.57E_03 4.59E-03
- AP 04 45282 10/21/98 GR-B 1.47E-02 2.00E-03 5.36E-03
- AP 04 45416 10/28/98 GR-B 1.91E-02 1.54E-03 3.77E-03 *
'AP 04 45510 11/04/98 GR-B 7.77E-03 1.64E-03 4.61E-03
- AP 04 45692 11/10/98 GR-B 1.27E-02 1.52E-03 3.96E-03
- AP 04 45722 11/18/98 GR-B 2.65E-02 1.55E-03 3.41E-03
- AP 04 45872 11/25/98 GR-B 2.45E-02 1.86E-03 4.46E-03
- AP 04 46114 12/02/98 GR-B 2.12E-02 1.66E-03 3.89E-03
- AP 04 46183 12/09/98 GR-B 2.85E-02 1.82E-03 4.02E-03
- AP 04 46130 12/16/98 GR-B 2.61E-02 1.85E-03 4.44E-03
- AP 04 46528 12/23/98 GR-B 2.14E-02 1.72E-03 4.21E-03
- AP 04 46593 12/30/98 GR-B 3.14E-02 1.98E-03 4.76E-03
- 9
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END'DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) (pCi/cu.m) AP 05 40296 01/07/98 GR-B 1.75E-02 1.47E-03 3.67E-03
- AP 05 40371 01/14/98 GR-B 1.67E-02 1.46E-03 3.71E-03 *
-AP 05 40536 01/21/98 GR-B 9.64E-03 1.41E-03 3.87E-03
- AP 05 40625 '01/28/98 GR-B 2.07E-02 1.39E-03 3.06E-03
- AP 05 40696 02/04/98 GR-B 1.97E-02 1.55E-03 3.81E-03
- AP 05 40862 02/11/98 GR-B 2.60E-02 1.62E-03 3.73E-03
- AP 05 40930 02/18/98 GR-B 1.91E-02 1.57E-03 4.01E-03
- AP 05 41042 02/25/98 GR-B 9.63E-03 1.39E-03 3.93E-03
- AP 05 41219 03/04/98 GR-B 6.32E-03 1.46E-03 4.41E-03 *
.AP 05 41414 03/18/98 GR-B 2.31E-02 1.63E-03 3.95E-03
- AP 05 41512 03/25/98 GR-B 1.71E-02 1.58E-03 4.08E-03
- AP 05 41581 04/01/98 GR-B 2.62E-02 1.64E-03 3.95E-03
- AP 05 41621 04/08/98 GR-B 8.05E-03 1.34E-03 3.55E-03
- AP 05 41823 04/15/98 GR-B 2.69E-02 1.49E-03 3.01E-03
- AP .05 41965 04/22/98 GR-B 1.74E-02 1.27E-03 2.99E-03
- AP 05 41992 04/29/9 GR-B 1.28E-02 1.23E-03 3.17E-03
- AP 05 42131 05/06/o'- GR-B 1.80E-02 1.33E-03 2.99E-03
- AP 05 42223 05/13/>. GR-B 9.56E-03 1.40E-03 3.83E-03
- AP 05 42340 05/20/9S GR-D 1.80E-02 1.35E-03 3.09E-03
- AP 05 42433 05/27/98 GR-B 2.19E-02 1.68E-03 4.05E-03
- AP 05 42543 06/03/98 GR-B 2.30E-02 1.59E-03 3.72E-03
- AP 05 42621 06/10/98 GR-B 9.82E-03 1.37E-03 3.75E-03
- AP 05 42720 06/17/98 GR-B 1.56E-02 1.41E-03 3.63E-03
- AP 05 42792 06/24/98 GR-B 1.03E-02 1.29E-03 3.53E-03
- AP 05 42910 07/01/98 GR-B 1.33E-02 1.51E-03 3.97E-03
- AP 05 43000 07/08/98 GR-B 8.95E-03 1.33E-03 3.66E-03
- AP 05 43078 07/15/98 GR-B 1.70E-02 1.69E-03 4.14E-03
- AP 05 43169 07/22/98 GR-B 2.70E-02 1.71E-03 4.00E-03
- AP 05 43312 07/29/98 GR-B 1.84E-02 1.54E-03 3.89E-03
- AP 05 43385 08/05/98 GR-B 1.82E-02 1.61E-03 4.09E-03
- AP 05 43517 08/12/98 GR-B 2.84E-02 1.70E-03 3.86E-03
- AP 05 43651 08/19/98 GR-B 1.13E-02 1.49E-03 4.10E-03
- AP 05 43878 08/26/98 GR-B 2.70E-02 1.56E-03 3.31E-03
- AP 05 44073 09/02/98 GR-B 2.68E-02 1.80E-03 4.20E-03
- AP 05 44169 09/09/98 GR-B 2.42E-02 1.61E-03 3.78E-03
- AP 05 44272 09/16/98 GR-B 1.67E-02 1.41E-03 3.52E-03
- AP 05 44358 09/23/98 GR-B 2.20E-02 1.65E-03 4.12E-03
- AP 05 44663 09/30/98 GR-B 2.57E-02 1.53E-03 3.31E-03
- l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC-TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) ,(pCi/cu.m) j AP 05' 45079 10/07/98 GR-B 1.77E-02 1.35E-03 3.22E-03 * ) AP 05 45103 10/14/98 GR-B 9.53E-03 1.48E-03 4.21E-03
- j AP 05 45283 10/21/98 GR-B 1.68E-02 1.59E-03 4.17E-03
- i AP 05 45417 10/28/98 GR-B 1.74E-02 1.38E-03 3.33E-03
- AP 05 45511 11/04/98 GR-B 9.03E-03 1.51E-03 4.16E-03
- i AP 05 45693 11/10/98 GR-B 1.26E-02 1.44E-03 3.66E-03
- AP 05 45723 11/18/98 GR-B 2.57E-02 1.41E-03 3.06E-03
- AP 05 45873 11/25/98 GR-B 1.95E-02 1.61E-03 3.95E-03
- AP 05 46115 12/02/98 GR-B 1.96E-02 1.47E-03 3.45E-03
- AP 05 46184 12/09/98 GR-B 2.59E-02 1.64E-03 3.59E-03
- AP 05 46131 12/16/98 GR-B 2.37E-02 1.71E-03 4.01E-03
- AP 05- 46529 12/23/98 GR-B 2.16E-02 1.61E-03 3.81E-03
- AP 05 46594 12/29/98 GR-B 4.05E-02 2.10E-03 4.81E-03 *
- Radioactivity detected-in sample (i . e . , CONC > 3 STD. DEV. )
r Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) ,(pCi/cu.m) AP 06 40297. 01/06/98 GR-B 2.34E-02 1.83E-03 4.55E-03
- AP 06 40372 01/14/98 GR-B 1.63E-02 1.42E-03 3.66E-03
- AP 06 40537 01/21/98 GR-B 1.27E-02 1.57E-03 4.26E-03
- i AP 06 40626 01/28/98 GR-B 2.34E-02 1.50E-03 3.36E-03
- AP 06 40697 02/04/98 GR-B 2.16E-02 1.69E-03 4.09E-03
- AP 06 40863 02/11/98 GR-B 2.67E-02 1.74E-03 4.08E-03
- AP 06 40931 02/18/98 GR-B 2.18E-02 1.64E-03 4.13E-03
- AP 06 41043 02/25/98 GR-B 7.57E-03 1.45E-03 4.14E-03 * ,
AP 06 41220 03/04/98 GR-B 6.06E-03 1.53E-03 4.56E-03
- AP 06 41302 03/11/98 GR-B 1.22E-02 1.59E-03 4.13E-03
- AP 06 41415 03/18/98 GR-B 2.63E-02 1.75E-03 4.17E-03
- AP 06 41513 03/25/98 GR-B 1.91E-02 1.69E-03 4.30E-03
- AP 06 41582 04/01/98 GR-B 2.77E-02 1.80E-03 4.33E-03
- AP 06 41622 04/08/98 GR-B 7.89E-03 1.53E-03 4.13E-03
- j AP 06 41824 04/15/98 GR-B 2.54E-02 1.61E-03 3.46E-03
- AP 06 41966 04/22/98 GR-B 1.72E-02 1.43E-03 3.41E-03
- AP 06 41993 04/29/98 GR-B 1.55E-02 1.42E-03 3.57E-03
- AP 06 42132 05/06/98 GR-B 1.70E-02 1.43E-03 3.39E-03 * .
AP 06 42224 05/13/98 GR-B 9.66E-03 1.52E-03 4.16E-03
- l l AP 06 42341 05/20/98 GR-B 1.68E-02 1.45E-03 3.48E-03
- I l AP 06 42434 05/27/98 GR-B 2.01E-02 1.81E-03 4.37E-03
- l l AP 06 42544 06/03/98 GR-B 2.01E-02 1.67E-03 4.13E-03
- l AP 06 42622 06/10/98 GR-B 1.06E-02 1.50E-03 4.08E-03
- AP 06 42721 06/17/98 GR-B 1.56E-02 1.58E-03 4.09E-03
- AP 06 42793 06/24/98 GR-B 1.23E-02 1.41E-03 3.75E-03
- AP 06 42911 07/01/98 GR-B 1.93E-02 2.49E-03 6.75E-03
- i AP 06 43001 07/08/98 GR-B 8.47E-03 1.38E-03 3.88E-03
- l AP 06 43079 07/15/98 GR-B 1.50E-02 1.69E-03 ,4.41E-03
- AP 06 43170 07/22/98 GR-B 2.65E-02 1.79E-03 4.29E-03
- AP 06 43313 07/29/98 GR-B 1.83E-02 1.63E-03 4.20E-03
- AP 06 43386 08/05/98 GR-B 1.80E-02 1.74E-03 4.43E-03
- AP 06 43518 08/12/98 GR-B 2.53E-02 1.69E-03 4.09E-03
- AF 06 43652 08/19/98 GR-B 1.55E-02 1.70E-03 4.54E-03
- AP 06 43879 08/26/98 GR-B 2.99E-02 1.68E-03 3.57E-03
- AP 06 44074 09/02/98 GR-B 1.98E-02 1.72E-03 4.33E-03 *.
AP 06 44170 09/09/98 GR-B 2.53E-02 1.77E-03 4.17E-03
- AP 06 44273 09/16/98 GR-B 1.96E-02 1.53E-03 3.81E-03
- AP 06 44359 09/23/98 GR-B 2.08E-02 1.79E-03 4.62E-03
- AP 06 44664 09/30/98 GR-B 2.79E-02 1.64E-03 3.55E-03 *
- Radioactivity detected in sample (i.e. , CONC > 3 STD. DEV. )
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC
. TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) , (pCi/cu.m)
AP 06 45080 10/07/98 GR-B 1.60E-02 1.45E-03 3.61E-03
- AP 06 45104 10/14/98 GR-B 8.79E-03 1.61E-03 4.60E-03
- AP 06 45284 10/21/98 GR-B 1.75E-02 1.74E-03 4.50E-03
- AP 06 45418 10/28/98 GR-B 1.67E-02 1.50E-03 3.71E-03
- AP 06 45512 11/04/98 GR-B. 9.05E-03 1.65E-03 4.55E-03
- AP 06 45694 11/10/98 GR-B 1.12E-02 1.57E-03 4.06E-03
- AP 06 45724 11/18/98 GR-B 2.59E-02 1.52E-03 3.39E-03
- AP 06 45874 11/25/98 GR-B 2.30E-02 1.79E-03 4.33E-03
- AP 06 46116 12/02/98 GR-B '2.39E-02 1.71E-03 3.82E-03
- AP 06 46185 12/09/98 GR-B 2.96E-02 1.76E-03 3.88E-03
- AP 06 46132 12/16/98 GR-B 3.06E-02 2.00E-03 4.50E-03
- AP 06 46530 12/23/98 GR-B 2.33E-02 1.73E-03 4.03E-03
- AP 06 46595 12/29/98 GR-B 3.60E-02 2.30E-03 5.54E-03
- l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l . , .
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ).(pCi/cu.m) AP 07 40298 01/07/98 GR-B 1.80E-02 1.55E-03 3.93E-03
- AP 07 40373 01/14/98 GR-B 1.49E-02 1.54E-03 4.06E-03
- AP 07 40538 01/21/98 GR-B 1.40E-02 1.63E-03 4.28E-03
- AP 07 40627 01/28/98 GR-B 2.00E-02 1.45E-03 3.33E-03
- AP 07 40698 02/04/98 GR-B 2.17E-02 1.67E-03 4.06E-03
- AP 07 40864 02/11/98 GR-B 2.46E-02 1.72E-03 4.10E-03
- AP 07 40932 02/18/98 GR-B 2.12E-02 1.63E-03 4.11E-03
- AP 07 41044 02/25/98 GR-B 9.86E-03 1.43E-03 4.02E-03
- AP 07 41221 03/04/98 GR-B 9.51E-03 1.55E-03 4.52E-03
- AP 07 41303 03/11/98 GR-B 1.16E-02 1.56E-03 4.06E-03
- AP 07 41416 03/18/98 GR-B 2.23E-02 1.70E-03 4.15E-03
- AP 07 41514 03/25/98 GR-B 1.81E-02 1.61E-03 4.22E-03
- AP 07 41583 04/01/98 GR-B 2.29E-02 1.72E-03 4.30E-03
- AP 07 41623 04/08/98 GR-B 9.27E-03 1.52E-03 4.07E-03
- AP 07 41825 04/15/98 GR-B 2.57E-02 1.60E-03 3.45E-03
- AP 07 41967 04/22/98 GR-B 1.90E-02 1.44E-03 3.39E-03
- AP 07 41994 04/29/98 GR-B 1.39E-02 1.40E-03 3.60E-03
- AP 07 42133 05/06/98 GR-B 1.47E-02 1.37E-03 3.35E-03
- AP 07 42225 05/13/98 GR-B 1.01E-02 1.57E-03 4.21E-03
- AP 07 42342 05/20/98 GR-B 1.45E-02 1.37E-03 3.37E-03
- AP 07 42435 05/27/98 GR-B 1.96E-02 1.76E-03 4.33E-03
- AP 07 42545 06/03/98 GR-B 2.27E-02 1.66E-03 4.03E-03
- AP 07 42623 06/10/98 GR-B 1.12E-02 1.52E-03 4.11E-03
- AP 07 42722 06/17/98 GR-B 1.55E-02 1.58E-03 4.12E-03
- AP 07 42794 06/24/98 GR-B 1.16E-02 1.35E-03 3.64E-03
- AP 07 42912 07/01/98 GR-B 1.52E-02 1.61E-03 4.22E-03
- AP 07 43002 07/08/98 GR-B 8.44E-03 1.39E-03 3.89E-03
- AP 07 43080 07/15/98 GR-B 1.34E-02 1.68E-03 4.37E-03
- AP 07 43171 07/22/98 GR-B 2.61E-02 1.78E-03 '4.25E-03
- AP 07 43314 07/29/98 GR-B 1.65E-02 1.57E-03 4.11E-03
- AP 07 43387 08/05/98 GR-B 1.66E-02 1.74E-03 4.47E-03
- AP 07 43519 08/12/98 GR-B 2.37E-02 1.'E 8 E- 03 4.07E-03
- AP 07 43653 08/19/98 GR-B 1.29E-02 1.70E-03 4.50E-03
- AP 07 43880 08/26/98 GR-B 2.49E-02 1.63E-03 3.53E-03
- AP 07 44075 09/02/98 GR-B 1.96E-02 1.74E-03 4.24E-03
- AP 07 44171 09/09/98 GR-B 2.52E-02 1.79E-03 4.30E-03
- AP 07 44274 09/16/98 GR-B 1.71E-02 1.50E-03 3.76E-03
- AP 07 44360 09/23/98 GR-B 1.98E-02 1.75E-03 4.40E-03
- AP 07 44665 09/30/98 GR-B 2.43E-02 1.58E-03 3.58E-03 *
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
r
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program , Summary of 1998 Data SAMPLE CONC. TYPE STD DEV. MDC STA. LSN END DATE NUCLIDE (pCi/cu.m) ( _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ pC i / cu . m ) , ( pCi / c u . m AP 07 45081 10/07/98 GR-B 1.75E-02 1.46E-03 3.55E-03
- AP 07 45105 10/14/98 GR-B 8.20E-03 1.56E-03 4.59E-03
- AP 07 45285 10/21/98 GR-B 1.86E-02 AP 1.74E-03 4.53E-03
- 07 45419 10/28/98 GR-B 1.78E-02 1.47E-03 3.62E-03
- AP 07 45513 11/04/98 GR-B 9.67E-03 1.63E-03 4.51E-03
- AP 07 45695 11/10/98 GR-B 8.85E-03 1.48E-03 3.99E-03
- AP 07 45725 '11/18/98 GR-B 2.54E-02 1.54E-03 3.41E-03
- AP 07 45875 11/25/98 GR-B 2.03E-02 1.69E-03 4.22E-03
- AP 07 46117 12/02/98 GR-B 1.77E-02 1.52E-03 3.71E-03
- AP 07 46186 12/09/98 GR-B 2.70E-02 1.75E-03 3.84E-03
- AP 07 46133 12/16/98 GR-B 2.69E-02 1.93E-03 4.53E-03
- AP 07 46531 12/23/98 GR-B 2.14E-02 1.68E-03 4.00E-03
- AP 07 46596 12/29/98 GR-B 3.19E-02 2.18E-03 5.42E-03 *
- Radioactivity detected in sample (i.e. , CONC > 3 STD. DEV. )
[
n l 1 Seabrook Nuclear Power Station
, Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCUcu .m) (pCi/cu.m ) , (pCi/cu.m)
AP 08 40299 01/07/98 GR-B 1.78E-02 1.58E-03 3.99E-03
- AP 08 40374 01/14/98 GR-B 1.60E-02 1.57E-03 4.11E-03
- AP 08 40539 01/21/98 GR-B 1.31E-02 1.59E-03 4.25E-03
- AP 08 40628 01/28/98 GR-B 2.23E-02 1.48E-03 3.31E-03
- AP 08 40699 02/04/98 GR-B 2.11E-02 1.67E-03 4.12E-03
- AP 08 40865 02/11/98 GR-B 2.88E-02 1.75E-03 3.99E-03
- AP 08 40933 02/18/98 GR-B 1.96E-02 1.67E-03 4.23E-03
- AP 03 41045 02/25/98 GR-B 9.13E-03 1.46E-03 4.10E-03
- AP 08 41222 03/04/98 GR-B 5.35E-03 1.52E-03 4.56E-03
- AP 08 41304 03/11/98 GR-B 1.15E-02 1.61E-03 4.10E-03
- AP 08 41417 03/18/98 GR-B 2.35E-02 1.72E-03 4.19E-03
- l AP 08 41515 03/25/98 GR-B 1.57E-02 1.59E-03 4.27E-03
- i AP OR 41584 04/01/98 GR-B 2.35E-02 1.73E-03 4.33E-03
- AP 08 41624 04/08/98 GR-B 7.27E-03 1.54E-03 4.11E-03
- AP 08 41826 04/15/98 GR-B 2.44E-02 1.59E-03 3.49E-03
- AP 08 41968 04/22/98 GR-B 1.83E-02 1.42E-03 3.42E-03
- AP 08 41995 04/29/98 GR-B 1.49E-02 1.85E-03 5.00E-03
- AP- 08 42134 05/06/98 'GR-B 1.27E-02 1.61E-03 4.07E-03
- AP 08 42226 05/12/98 GR-B 1.04E-02 1.76E-03 4.78E-03
- AP 08 42343 05/20/98 GR-B 1.43E-02 1.26E-03 3.06E-03
- AP 08 42436 05/27/98 GR-B 1.61E-02 1.76E 4.43E-03 *
'AP 08 42546 06/03/98 GR-B 1.92E-02 1.66E-03 4.05E-03
- AP 08 42624 06/10/98 GR-B 9.86E-03 1.51E-03 4.15E-03
- AP 08 42723 06/17/98 GR-B 1.57E-02 1.55E-03 4.00E-03
- AP 08 42795 06/24/98 GR-B 1.06E-02 1.40E-03 3.81E-03
- AP 08 42913 07/01/98 GR-B 1.45E 02 1.62E-03 4.27E-03
- AP 08 43003 07/08/98 GR-B 7.57E-OJ 1.39E-03 3.91E-03
- AP 08 43001 07/15/98 GR-B 1.16E-02 1.72E-03 4.40E-03
- AP 08 43172 07/22/98 GR-B 2.38E-02 1.77E-03 4.23E-03
- AP 08 43315 07/29/98 GR-B 1.43E-02 1.62E-03 4.24E-03
- AP 08 43388 08/05/98 GR-B 1.94E-02 1.72E-03 4.3RE-03
- AP 08 43520 08/12/98 GR-B 2.24E-02 1.70E-03 4.17E-03
- AP 08 43654 08/19/98 GR-B 9.82E-03 1.65E-03 4.45E-03
- AP 08 43881 08/26/98 GR-B 2.18E-02 1.57E-03 3.59E-03
- l AP 08 44076 09/02/98 GR-B 2.04E-02 1.75E-03 4.27E-03
- l AP 08 44172 09/09/98 GR-B 2.39E-02 1.73E-03 4.26E-03
- AP 08 44275 09/16/98 GR-B 1.53E-02 1.49E-03 3.79E-03
- AP 08 44361 09/23/98 GR-B 2.39E-02 1.91E-03 4.75E-03
- l AP 08 44666 09/30/98 GR-B 2.33E-02 1.59E-03 3.60E-03
- j
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
m Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m ) _____________________________________.______________________________,(pCi/cu.m) AP 08 45082 10/07/98 GR-B 1.33E-02 1.41E-03 3.61E-03
- AP 08 45106 10/14/98 GR-B 8.29E-03 1.59E-03 4.59E-03
- l AP 08 45286 10/21/98 GR-B 1.74E-02 1.73E-03 4.52E-03
- AP 08 45420 10/28/98 GR-B 1.64E-02 1.47E-03 3.70E-03
- AP 08 45514 11/04/98 GR-B 8.64E-03 1.60E-03 4.50E-03
- AP 08 45696 11/10/98 GR-B 1.23E-02 1.56E-03 4.08E-03
- AP 08 45726 11/18/98 GR-B 2.53E-02 1.51E-03 3.38E-03
- AP 08 45876 11/25/98 GR-B 2.01E-02 1
1.71E-03 l 4.31E-03
- I l
AP 08 46118 12/02/98 GR-B 2.05E-02 1.61E-03 3.79E-03
- AP 08 46187 12/09/98 GR-B 2.76E-02 1.74E-03 3.88E-03
- AP 08 46134 12/16/98 GR-B 2.53E-02 1.84E-03 4.42E-03
- AP 08 46532 12/23/98 GR-B 1.95E-02 1.66E-03 4.12E-03
- AP' 08 46597 12/30/98 GR-B 3.39E-02 1.99E-03 4.71E-03 *
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i l
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) 1 AP 01 41854 04/01/98 Ag-110M -1.40E-04 5.05E-04 2.19E-03 AP 01 41854 04/01/98 Ba-140 4.13E-03 1.87E-02 8.23E-02 AP 01 41854 04/01/98 Be-7 5.80E-02 1.27E-02 3.39E-02
- AP 01 41854 04/01/98 Ce-141 2.38E-03 1.32E-03 3.81E-03 AP 01 41854 04/01/98 Ce-144 -3,83E-04 1.10E-03 3.97E-03 AP 01 41854 04/01/98 Co-57 2.93E-04 1.37E-04 3.77E-04 AP 01 41854 04/01/98 Co-58 -2.54E-04 2.20E-04 1.71E-03 >
AP 01 41854 04/01/98 Co-60 6.30E-05 4.36E-04 1.85E-03 l AP 01 41854 04/01/98 Cr-51 4.98E-03 1.25E-02 4.57E-02 AP 01 41854 04/01/98 Cs-134 -8.99E-05 1.91E-04 9.04E-04 , AP 01 41854 04/01/98 Cs-137 -6.99E-05 2.26E-04 1.08E-03 ! AP 01 41854 04/01/98 Fe-59 1.50E-03 2.54E-03 1.06E-02 AP 01 41854 04/01/98 I-131 -6.38E-03 6.93E-02 0.27E+00 AP 01- 41854 04/01/98 K-40 7.54E-03 4.57E-03 1.33E-02 AP 01 41854 04/01/98 Mn-54 -1,37E-04 1.19E-04 9.24E-04 AP 01 41854 04/01/98 Ru-103 5.84E-04 7.68E-04 2.85E-03 AP 01 41854 04/01/98 Ru-106 -5.01E-03 3.32E-03 1.59E-02 AP 01 41854 04/01/98 Sb-124 3.55E-03 2.25E-03 5.79E-03 AP G1 41854 04/01/98 Se-75 ' -6.12E-05 4.38E-04 1.65E-03 AP 01 41854 04/01/98 Th-232 0.00E+00 1.36E-03 5.48E-03 AP 01 41854 04/01/98 Zn-65 -6.25E-04 6.98E-04 3.75E-03 AP 01 41854 04/01/98 Zr-95 1.39E-03 1.03E-03 3.40E-03 AP 01 43090 07/01/98 Ag-110M -6.72E-04 1.13E-04 1.88E-03 AP 01 43090 07/01/98 Ba-140 1.10E-02 8.03E-03 2.52E-02 AP 01 43090 07/01/98 Be-7 0.10E+00 1.16E-02 1.64E-02
- AP 01 43090 07/01/98 Ce-141 -1.82E-03 6.45E-04 2.86E-03 AP 01 43090 07/01/98 Ce-144 6.52E-04 9.67E-04 3.17E-03 AP 01 43090 07/01/98 Co-57 1.06E-04 1.13E-04 3.61E-04 AP 01 43090 07/01/98 Co-58 -9.57E-05 2.79E-04 1.46E-03 AP 01 43090 07/01/98 Co-60 -2.95E-04 4.04E-04 1.97E-03 1 AP 01 43090 07/01/98 Cr-51 -8.63E-03 7.56E-03 3.18E-02 )
AP 01 43090 07/01/98 Cs-134 0.00E+00 2.36E-04 9.45E-04 AP 01 43090 07/01/98 Cs-137 -2.80E-04 2.47E-04 1.22E-03 AP 01 43090 07/01/98 Fe-59 -1.03E-03 9.62E-04 7.26E-03 - I AP 01 43090 07/01/98 I-131 -1.94E-03 1.41E-02 5.56E-02 AP 01 43090 07/01/98 K-40 3.44E-03 5.29E-03 1.99E-02 ) AP 01 43090 07/01/98 Mn-54 -2.36E-04 2.12E-04 1.14E-03 AP 01 43090 07/01/98 Ru-103 -1.40E-05 6.35E-04 2.57E-03 AP 01 43090 07/01/98 Ru-106 4.32E-03 2.86E-03 9.30E-03 'AP 01 43090 07/01/98 Sb-124 0.00E+00 1.29E-03 6.65E-03 I AP 01 43090 07/01/98 Se-75 1.42E-04 3.34E-04 1.20E-03 AP 01 43090 07/01/98 Th-232 -7.96E-04 1.07E-03 4.90E-03 i AP 01 43090 07/01/98 Zn-65 3.28E-04 5.56E-04 2.31E-03 AP 01 '43090 07/01/98 Zr-95 -4.28E-04 5.61E-04 3.00E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I
Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program l Summary of 1998 Data SAMPLE CONC. STD DEV. MDC ; TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) l AP 01 45190 09/30/98 Ag-110M -6.02E-04 4.56E-04 2.12E-03 AP 01 45190 09/30/98 Ba-140 -1.26E-02 5.62E-03 3.47E-02 AP 01 45190 09/30/98 Be-7 8.38E-02 1.21E-02 2.74E-02
- AP 01 45190 09/30/98 Ce-141 3.58E-04 8.87E-04 2.93E-03 AP 01 45190 09/30/98 Ce-144 -4.63E-04 1.14E-03 4.02E-03 i AP 01 45190 09/30/98 Co-57 -2.44E-05 1.32E-04 4.60E-04 l AP 01 45190 09/30/98 Co-58 -8.63E-05 4.69E-04 1.94E-03 AP 01 45190 09/30/98 Co-60 0.00E+0C 2.01E-04 1.03E-03 1 AP 01 45190 09/30/98 Cr-51 -2.28E-02 8.96E-03 3.93E-02 !
AP 01 45190 09/30/98 Cs-134 -3.63E-04 2.81E-04 1.26E-03 AP 01 45190 09/30/98 Cs-137 -3.27E-04 2.94E-04 1.34E-03 l AP 01 45190 09/30/98 Fe-59 -1.46E-03 1.63E-03 8.74E-03 i AP 01 45190 09/30/98 I-131 -6.15E-04 1.74E-02 6.47E-02 l AP 01 45190 09/30/98 K-40 0.00E+00 5.07E-03 2.06E-02 l AP 01 45190 09/30/98 Mn-54 3.71E-04 2.62E-04 8.10E-04 l AP 01 45190 09/30/98 Ru-103 -2.60E-04 7.29E-04 2.92E-03 AP 01 45190 09/30/98 Ru-106 0.00E+00 2.25E-03 9.54E-03 AP 01 45190 09/30/98 Sb-124 4.80E-04 1.77E-03 7.32E-03 , AP 01 45190 09/30/98 Se-75 7.23E-04 3.77E-04 1.13E-03 ' AP 01 45190 09/30/98 Th-232 7.12E-04 1.20E-03 4.38E-03 AP 01 45190 09/30/98 Zn-65 2.17E-04 9.41E-04 3.66E-03 AP 01 45190 09/30/98 Zr-95 -5.43E-04 6.81E-04 3.26E-03 AP 01 47049 12/29/98 Ag-110M 1.83E-04 3.04E-04 1.24E-03 ed 01 47049 12/29/98 Ba-140 -5.63E-03 5.04E-03 3.87E-02 AP 01 47049 12/29/98 Be-7 6.00E-02 1. lee-02 2.67E-02
- AP 01 47049 12/29/98 Ce-141 1.68E-03 8.76E-04 2.50E-03 l AP 01 47049 12/29/98 Ce-144 -2.66E-01 8.373-04 3.09E-03 AP 01 47049 12/29/98 Co-57 -8.16E-05 9.66E-05 3.80E-04 AP 01 47049 12/29/98 Co-58 -5.69E-04 4.04E-04 2.17E-03 l AP 01 47049 12/29/98 Co-60 -3 38E-04 2.39E-04 ,
1.57E-03 AP 01 47049 12/29/98 Cr-51 4.87E-03 8.07E-03 2.92E-02 AP 01 47049 12/29/98 Cs-134 -3.44E-04 2.55E-04 1.22E-03 AP 01 47049 12/29/98 Cs-137 9.35E-05 3.10E-04 1.23E-03 AP 01 47049 12/29/98 Fe-59 5.80E-04 1.39E-03 6.71E-03 l AP 01 47049 12/29/98 I-131 1.51E-02 2.79E-02 0.10E+00 ' AP 01 47049 12/29/98 K-40 5.65E-04 5.66E-03 2.25E-02 AP 01 47049 12/29/98 Mn-54 1.20E-04 1.99E-04 8.09E-04 AP 01 47049 12/29/98 Ru-103 8.01E-05 4.42E-04 1.97E-03 AP 01 47049 12/29/98 Ru-106 -7.32E-04 1.93E-03 9.25E-03 AP 01 47049 12/29/98 Sb-124 3.43E-03 2.19E-03 6.41E-03 AP 01 47049 12/29/98 Se-75 -1.76E-04 3.29E-04 1.32E-03 AP 01 47049 12/29/98 Th-232 -2.99E-04 1.25E-03 5.15E-03 AP 01 47049 12/29/98 Zn-65 -1.09E-03 8.62E-04 4.26E-03 AP 01 47049 12/29/98 Zr-95 2.80E-04 8.07E-04 3.26E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i
l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pC3/cu.m) l AP 02 41655 04/01/98 Ag-110M -2.73E-04 3.58E-04 1.91E-03 { AP 02 41855 04/01/98 Ba-140 1.08E-02 1.81E-02 7.41E-02 AP 02 41855 04/01/98 Be-7 7.31E-02 1.69E-02 5.01E-02
- l AP 02 41855 04/01/98 Ce-141 -2.30E-03 1.26E-03 5.02E-03 l AP 02 41855 04/01/98 Ce-144 7.91E-05 1.10E-03 3.05E-03
[ AP 02 41855 04/01/98 Co-57 3.30E-04 1.38E-04 3.65E-04 l AP 02 41855 04/01/98 Co-58 -4.61E-04 5.78E-04 2.77E-03 l AP 02 41855 04/01/98 Co-60 1.97E-04 3.41E-04 1.45E-03 l~ AP 02 41855 04/01/98 Cr-51 1.2SE-02 1.21E-02 4.10E-02 AP 02 41855 04/01/98 Cs-134 -1.86E-04 3.48E-04 1.48E-03
- AP 02 41855 04/01/98 Cs-137 2.17E-04 2.17E-04 7.99E-04 AP 02 41855 04/01/98 Fe-59 -2.73E-03 1.93E-03 1.32E-02 AP 02 41855 04/01/98 I-131 -6.58E-03 7.63E-02 0.30E+00 AP 02 41855 04/01/98 K-40 -1.18E-03 6.31E-03 2.64E-02 AP 02 41855 04/01/98 Mn-54 -7.12E-05 3.87E-04 1.60E-03 l AP 02 41855 04/01/98 Ru-10
- 8.05E-04 6.13E-04 1.93E-03 AP 02 41855 04/01/98 Ru-106 -2.08E-03 3.28E-03 1.46E-02 AP 02 41855 04/01/98 Sb-124 -1.33E-03 1.26E-03 9.43E-03 AP 02 41855 04/01/98 Se-75 -3.48E-04 3.18E-04 1.43E-03 l AP 02 41855 04/01/98 Th-232 2.10E-03 1.42E-03 4.56E-03
-AP 02 41855 04/01/98 Zn-65 2.J0E-04 1.07E-03 4.35E-03 l A7 02 41855 04/01/98 Zr-95 -2.40E-04 6.99E-04 3.67E-03 l .1P 02 43091 07/01/98 Ag-110M -4.20E-04 2.42G-04 1.63E-03 l
AP 02 43091 07/01/98 Ba-140 4.15E-03 6.22E-03 2.51E-02 j AP 02 43091 07/01/98 Be-7 0.12E+00 1.50E-02 3.36E-02
- AP 02 43091 07/01/98 Ce-141 -4.29E-04 8.58E-04 3.07E-03 AP 02 43091 07/01/98 Ce-144 4.82E-04 9.26E-04 3.12E-03 AP 02 43091 ^7/01/98 Co-57 -1.15E-04 1.07E-04 4.22E-04 AP 02 43091 ^'/01/98 Co-58 5.99E-04 5.74E-04 1.93E-03 AP 02 43091 Os/01/98 Co-60 -3.48E-04 3.48E-04 1.87E-03 AP 02. 43091 07/01/98 Cr-51 -3.27E-04 8.00E-03 3.05E-02 AP 02 43091 07/01/98 Cs-134 -2.48E-04 3.20E-04 1.38E-03
'AP 02 43091 -07/01/98 Cs-137 -1.19E-04 2.63E-04 1.20E-03 l AP 02 43091 07/01/98 Fe-59 0.00E+00 1.46E-03 7.50E-03 AP 02 43091 07/01/98 I-131 1.37E-03 1.45E-02 5.61E-02
- AP 02 43091 07/01/98 K-40 5.63E-03 5.68E-03 2.02E-02 AP 02 43091 07/01/98 Mn-54 -3.07E-05 2.36E-04 1.08E-03 l AP 02 43091 07/01/98 Ru-103 2.20E-04 6.36E-04 2.47E-03 i AP 02 43091 07/01/98 Ru-106 0.00E+00 3.14E-03 1.28E-02 AP 02 43091 07/01/98 Sb-124 -9.61E-04 9.11E-04 6.84E-03 AP 02 43091 07/01/98 Se-75 -5.4CE-05 4.49E-04 1.65E-03 AP 02 43091 07/01/98 Th-232 -5.18E-04 8.97E-04 4.28E-03 AP 02 43091 07/01/98 Zn-65 8.50E-05 6.39E-04 2.88E-03 AP 02 43091 07/01/98 Zr-95 1.34E-03 9.92E-04 3.13E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
u
I? l Seabrook Nuclear Power Station ( Radiological Environmental Monitoring Program Summary of 1998 Data SAMPL2 CONC. STD DEV. MDC TYPE STA. LSN END DATE LUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 02 45191 09/30/98 Ag-110M 2.60E-04 2.97E-04 1.12E-03 AP 02 45191 09/30/98 Ba-140 5.03E-03 6.20E-03 2.40E-02 AP 02 45191 09/30/98 Be-7 0.12E+00 1.36E-02 2.55E-02
- I AP 02 45191 09/30/98 Ce-141 -5.35E-04 7.57E-04 AP 02 2.82E-03_ )
45191 09/30/08 Ce-144 1.14E-03 8.76E-04 2.70E-03 I
-AP 02 45191 09/30/96 Co-57 -1.69E-04 9.62E-05 4.11E-04 AP 02 45191 09/30/98 Co-58 2.02E-04 5.06E-04 1.96E-03 AP 02 45191 09/30/98 Co-60 8.89E-05 3.33E-04 1.49E-03 AP- 02 45191 09/30/98 Cr-51 9.77E-04 7.37E-03 2.80E-02 AP 02 45191 09/30/98 Cs-134 2.22E-04 2.54E-04 9.31E-04 AP 02 45191 09/30/98 Cs-137 -1.64E-04 1.89E-04 1.02E-03 AP 02 45191 09/30/98 Fe-59 -1.09E-03 1.02E-03 7.66E-03 AP 02 45191 09/30/98 I-131 3.14E-02 1.62E-02 4.73E-02 l AP 02 45291 09/30/98 K-40 2.43E-03 5.22E-03 2.04E-02 !
AP 02 45191 09/30/98 Mn-54 6.22E-05 2.20E-04 9.51E 04 j AP 02 45191 09/30/98 Ru-103 -4.42E-04 5.92E-04 2.70E-03 '
'AP C2 45191 09/30/98 Ru-106 -4.56E-03 2.04E-03 1.20E-02 i AP 02 45191 09/30/98 Sb-124 0.00E+00 1.36E-03 7.03E-03 i AP 02 45191 09/30/98 Se-75 -1.23E-04 3.86E-04 1.17E-03 AP 02 45191 09/30/98 Th-232 -6.31E-04 9.52E-04 4.60E-03 AP 02 45191 09/30/98 Zn-65 4.33E-C4 7.37E-04 2.93E-03 AP 02 45191 09/30/98 Zr-95 9.04E-05 9.44E-04 3.30E-03 AP 02 47050 12/29/98 Ag-110M 4.68E-05 4.89E-04 1.97E-03 AP 02 47050 12/29/98 Ba-140 -7.95E-03 9.70E-03 5.20E-02 AP 02 47050 12/29/98 Be-7 6.19E-02 1.18E-02 3.05E-02
- AP 02 -47050 12/29/98 Ce-141 1.24E-03 0.09E-04 2.42E-03 AP 02 47050 12/29/98 Ce-144 -2.07E-04 9.01E-04 3.28E-03 AP 02 47050 12/29/98 Co-57 -1.13E-04 1.17E-04 4.47E-04 AP 02 47050 12/29/98 Co-58 5.29E-04 4.79E-04 1.62E-03 AP 02 47050 12/29/98 Co-60 2.35E-04 2.77E-04 1.09E-03 AP 02 47050 12/29/98 Cr-51 -3.90E-04 1.19E-02 4.37E-02 AP 02 47050 12/29/98 Cs-134 1.80E-04 2.28E-04 8.57E-04 AP 02 47050 12/29/98 Cs-137 -1.60E-04 2.66E-04 1.22E-03 AP 02 47050 12/29/98 Fe-59 1.18E-03 1.99E-03 8.30E 03 AP 02 47050 12/29/98 I-131 1.87E-02 3.05E-02 0.11E+00 AP 02 47050 12/29/98 K-40 -6.85E-04 5.40E-03 2.23E-02 AP 02 47050 12/29/98 Mn-54 -3.07E-04 2.34E-04 1.26E-03 AP 02 47050 12/29/98 Ru-103 0.00E+00 3.36E-04 1.72E-03 AP 02 47050 12/29/98 Ru-106 -6.32E-03 3.25E-03 1.57E-02 AP 02 47050 12/29/98 Sb-124 0.00E+00 1.42E-03 7.34E-03 AP 02 47050 12/29/98 Se-75 -4.50E-04 3.69E-04 1.54E-03 AP 02 47050 12/29/98 Th-232 1.27E-03 1.30E-03 4.47E-03
-AP 02 47050 12/29/98 Zn-65 8.53E-05 6.41E-04 2.89E-03 AP 02 47050 12/29/98 Zr-95 -1.05E-03 7.45E-04 4.01E-03 l
l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l
p 1 l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 03 41856 04/01/98 Ag-110M 4.13E-04 5.62E-04 2.06E-03 AP 03 41856 04/01/98 Ba-140 0.00E+00 2.03E-02 0.10E+00 AP 03 41856 04/01/98 Be-7 6.65E-02 1.72E-02 4.44E-02
- AP 03 41856 04/01/98 Ce-141 -2.74E-03 1.28E-03 5.44E-03 AP 03 41856 04/01/98 Ce-144 -2.57E-04 1.02E-03 3.78E-03 AP 03 41856 04/01/98 Co-57 -2.12E-05 1.32E-04 4.81E-04 AP 03 41856 04/01/98 Co-58 -5.90E-04 5.32E-04 2.86E-03 AP 03 41856 04/01/98 Co-60 7.94E-0A 5.14E-04 1.56E-03 AP 03 41856 04/01/98 Cr-51 6.04E-03 1.57E-02 5.78E-02 AP 03 41856 04/01/98 Cs-134 3.32E-04 2.52E-04 8.17E-04 AP 03 41856 04/01/98 Cs-137 1.93E-05 3.24E-04 1.37E-03 AP 03 41856 04/01/98 Fe-59 -1.79E-03 1.68E-03 1.27E-02 I AP 03 41856 04/01/98 I-131 4.43E-02 0.12E+00 0.45E+00 l AP 03 41856 04/01/98 K-40 -5.47E-03 6.0GE-03 2.79E-02 )
AP 03 41856 04/01/98 Mn-54 2.68E-04 3.65E-04 1.34E-03 ! AP 03 41856 04/01/98 Ru-103 1.34E-03 1.22E-03 4.12E-03 AP 03 41856 04/01/98 Ru-10s 1.12E-03 2.96E-03 1.20E-02 AP 03 41856 04/01/98 Sb-124 -1.49E-03 1.33E-03 1.02E-32 AP 03 41856 04/01/38 Se-75 3.65E-04 4.32E-04 1.50E-03 I AP 03 41856 04/01/98 Th-232 -1.72E-03 1.09E-03 5.84E-03 AP 03 41856 04/01/98 Zn-65 -1.02E-03 1.04E-03 5.09E-03 AP 03 41856 04/01/98 Zr-95 -9.01E-05 1.54E-03 6.59E-03 AP 03 43092 07/01/98 Ag-110M 1.09E-04 4.81E-04 1.98E-03 AP 03 43092 07/01/98 Ba-140 -4.40E-03 3.93E-03 3.02E-02 AP 03 43092 07/01/98 Be-7 9.76E-02 1.57E-02 3.58E-02
- AP 03 43092 07/01/98 Ce-141 4.93E-04 8.59E-04 2.87E-03 AP 03 43092 07/01/98 Ce-144 9.07E-04 1.18E-03 3.82E-03 AP 03 43092 07/01/98 Co-57 -1.08E-04 1.11E-04 4.46E-04 AP 03 43092 07/01/98 Co-58 -4.07E-04 5.11E-04 2.45E-03 AP 03 43092 07/01/98 Co-60 3.05E-04 3.18E-04 1.18E-03 AP 03 43092 07/01/98 Cr-51 4.51E-03 7.54E-03 2.75E-02 i AP 03 43092 07/01/98 Cs-134 2.72E-04 3.11E-04 1.09E-03 l AP 03 43092 07/01/98 Cs-137 -6.82E-04 3.59E-04 1.80E-03 i AP 03 43092 07/01/98 Fe-59 3.11E-04 2.34E-03 1.05E-02 AP 03 43092 07/01/98 I-131 1.05E-02 1.10E-02 3.90E-02 AP 03 43092 07/01/98 K-40 -4.35E-03 5.00E-03 2.45E-02 AP 03 43092 07/01/98 Mn-54 3.94E-04 3.70E-04 1.25E-03 AP 03 43092 07/01/98 Ru-103 6.81E-04 7.56E-04 2.67E-03 AP 03 43092 07/01/98 Ru-106 4.21E-03 2.58E-03 7.75E-03 '
AP 03 43092 07/01/98 Sb-124 -2.03E-03 2.03E-03 1.09E-02 AP 03 43092 07/01/98 Se-75 5.67E-04 3.90E-04 1.24E-03 AP 03 43092 07/01/98 Th-232 -1.94E-03 1.11E-03 5.95E-03 ! AP 03 43092 07/01/98 Zn-65 2.48E-04 7.11E-04 3.10E-03 l AP 03 43092 07/01/98 Zr-95 1.21E-03 9.39E-04 3.14E-03 ! l l 1 1
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I 1 l r !
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD Dl;V. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 03 45192 09/30/98 Ag-110M ~5.35E-04 4.07E-04 2.19E-03 AP 03 45192 09/30/98 Ba-140 -1.73E-03 6.31E-03 3.31E-02 AP 03 45192 09/30/98 Be-7 0.15E+00 1.71E-02 3.54E-02
- AP 03 45192 09/30/98 Ce-141 0.00E+00 8.90E-04 3.12E-03 AP 03 45192 09/30/98 Ce-144 1.03E-03 1.11E-03 3.58E-03 AP 03 45192 09/30/98 Co-57 2.22E-05 1.66E-34 5.61E-04 AP 03 45192 09/30/98 Co-58 5.72E-05 5.97E-14 2.40E-03 AP 03 45192 09/30/98 Co-60 9.96E-05 3.73E-04 1.67E-03 AP 03 45192 09/30/98 Cr-51 -3.00E-03 8.39E-03 3.36E-02 AP 03 45192 09/30/98 Cs-134 -4.51E-05 3.60E-04 1.46E-03 AP 03 45192 09/30/98 Cs-137 3.11E-04 3 40E-04 1.24E-03 AP 03 45192 09/30/98 Fe-59 1.22E-03 2. SS-C3 8.59E-03 AP 03 45192 09/30/98 I-131 -3.15E-03 1. :-02 6.47E-02 AP 03 45192 09/30/98 K-40 -3.2fE-03 5 Ssd-03 2.47E-02 AP 03 45192 09/30/98 Mn-54 -2.82E-04 +.20s-01 1.77E-03 AP 03 45192 09/30/98 Ru-103 -1.60E-03 7.55E-04 3.78E-03 AP 03 45192 09/30/98 Ru-106 3.46E-03 3.06E-O's 1.07E-02 AP 03 45192 09/30/98 Sb-124 1.43E-03 2.79E-03 1.10E-02 AP 03 45192 09/30/98 Se-75 0.00E+00 3.82E-04 1.45E-03 AP 03 45192 09/30/98 Th-232 0.00E+00 9.20E-04 4.21E-03 AP 03 45192 09/30/98 Zn-65 -6.33E-04 7.07E-04 3.80E-03 AP 03 45192 09/30/98 Zr-95 1.02E-03 1. 3 2 E- 03 4.61E-03 AP 03 47051 12/30/98 Ag-110M 5.27E-04 5.23E-04 1.81E-03 AP 03 47051 12/30/98 Ba-140 -1,60E-02 9.25E-03 6.11E-02 AP 03 47051 12/30/98 Be-7 8.69E-02 1.42E-02 2.96E-02
- AP 03 47051 12/30/98 Ce-141 -2.95E-04 8.34E-04 3.17E-03 AP 03 47051 12/30/98 Ce-144 -9.35E-04 1.23E-03 4.56E-03 AP 03 47051 12/30/98 Co-57 3.50E-04 1.57E-04 4.29E-04 AP 03 47051 12/30/98 Co-58 -3.52E-04 5.45E-04 2.59E-03 AP 03 47051 12/30/98 Co-60 -2.10E-04 1.96E-04 1.48E-03 AP 03 47051 12/30/98 Cr-51 -1.25E-02 8.43E-03 3.97E-02 AP 03 47051 12/30/98 Cs-134 -3.63E-04 2.90E-04 1.36E-03 AP 03 47051 12/30/98 Cs-137 -2.20E-04 3.28E-04 1.52E-03 AP 03 47051 12/30/98 Fe-59 7.13E-04 1.71E-03 8.25E-03 AP 03 47051 12/30/98 I-131 -1.20E-03 2.73E-02 0.11E+00 AP 03 47051 12/30/98 K-40 -4.46E-03 5.14E-03 2.52E-02 AP 03 47051 12/30/98 Mn-54 -3.73E-05 2.87E-04 1.31E-03 AP 03 47051 12/30/98 Ru-103 -6.93E-04 9.05E-04 3.98E-03 Ar 03 47051 12/30/98 Ru-106 -2.19E-03 3.46E-03 1.54E-02 AP 03 47051 12/30/98 Sb-124 -1.26E-03 1.12E-03 8.63E-03 AP 03 47051 12/30/98 Se-75 5.97E-04 4.60E-04 1.50E-03 AP 03 47051 12/30/98 Th-232 6.62E-04 1.57E-03 5.96E-03 AP 03 47051 12/30/98 Zn-65 -1.09E-03 6.31E-04 4.06E-03 AP 03 47051 12/30/98 Zr-95 -4.62E-04 1.03E-03 4.97E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 04 41857 04/01/98 Ag-110M -4.22E-05 5.04E-04 2.01E-03 AP 04 41857 04/01/98 Ba-140 -1.25E-02 1.74E-02 9.28E-02 AP 04 41857 04/01/98 Be-7 7.17E-02 1.44E-02 3.62E-02
- AP 04 41857 04/01/98 Ce-141 -4.07E-04 1.25E-03 4.45E-03 AP 04 41857 04/01/98 Ce-144 -1.31E-03 1.05E-03 4.01E-03 AP 04 41857 04/01/98 Co-57 -1.53E-04 1.41E-04 5.24E-04 AP 04 41857 04/01/98 Co-58 7.96E-04 5.88E-04 1.86E-03 AP 04 41857 04/01/98 Co-60 -5.46E-04 3.31E-04 1.78E-03 AP 04 41857 04/01/98 Cr-51 3.08E-03 1.35E-02 4.96E-02 AP 04 41857 04/01/98 Cs-134 -4.38E-04 2.92E-04 1.32E-03 AP 04 41857 04/01/98 Cs-137 1.73E-04 2.92E-04 1.10E-03 AP 04 41857 04/01/98 Fe-59 -1.25E-03 1.17E-03 8.84E-03 AP 04 41857 04/01/98 I-131 -0.18E+00 8.47E-02 0.41E+00 AP 04 41857 04/01/98 K-40 -2.89E-03 4.05E-03 1.87E-02 AP 04 41857 04/01/98 Mn-54 2.75E-04 2.49E-04 8.40E-04 AP 04 41857 04/01/98 Ru-103 -9.54E-04 9.89E-04 4.28E-03 AP 04 41857 04/01/98 Ru-106 -1.63E-03 3.06E-03 1.30E-02 AP 04 41857 04/01/98 Sb-124 2.98E-03 2.64E-03 8.89E-03 AP 04 41857 04/01/98 Se-75 2.26E-04 4.41E-04 1.54E-03 AP 04 41857 04/01/98 Th-232 -1.14E-03 7.61E-04 4.09E-03 AP 04 41857 04/01/98 Zn-65 1.52E-04 8.08E-04 3.30E-03 AP 04 41857 04/01/98 Zr-95 3.90E-04 9.76E-04 3.78E-03 AP 04 43093 07/01/98 Ag-110M -1.18E-04 3.79E-04 1.65E-03 AP 04 43093 07/01/98 Ba-140 1.85E-03 6.82E-03 2.82E-02 AP 04 43093 07/01/98 :-7 0.10E+00 1.18E-02 2.22E-02
- AP 04 43093 07/01/98 Co-141 4.01E-04 8.88E-04 2.92E-03 AP 04 43093 07/01/98 Ce -14 4 1.04E-03 1.12E-03 3.54E-03 AP 04 43093 07/01/98 Co-57 3.03E-04 1.27E-04 3.43E-04 i AP 04 43093 07/01/98 Co-58 5.50E-04 5.30E-04 1.78E-03 '
AP 04 43093 07/01/98 Co-60 2.87E-04 2.83E-04 1.01E-03 AP 04 43093 07/01/98 Cr-51 -2.32E-03 8.38E-03 3.18E-02 l AP 04 43093 07/01/98 Cs-134 -3.55E-04 2.75E-04 1.24E-03 AP 04 43093 07/01/98 Cs-137 4.91E-04 2.66E-04 7.93E-04 AP 04 43093 07/01/98 Fe-59 -4.39E-04 1.80E-03 8.42E-03 AP 04 43093 07/01/98 I-131 -1.62E-02 1.55E-02 6.38E-02 AP 04 43053 07/01/98 K-40 5.73E-03 5.60E-03 2.06E-02 AP 04 43093 07/01/98 Mn-54 -1.56E-04 2.23E-04 1.06E-03 AP 04 43093 07/01/98 Ru-103 -7.02E-04 5.60E-04 2.62E-03 AP 04 43093 07/01/98 Ru-106 2.63E-03 2.54E-03 8.99E-03 AP 04 43093 07/01/98 Sb-124 4.70E-04 9.00E-04 4.18E-03 AP 04 43093 07/01/98 Se-75 1.36E-04 3.90E-04 1.38E-03 AP 04 43093 07/01/98 Th-232 -5.23E-04 1.12E-03 4.71E-03 AP 04 43093 07/01/98 Zn-65 -4.25E-04 6.37E-04 3.07E-03 AP 04 43093 07/01/98 Zr-95 -5.32E-04 6.67E-04 3.20E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 04 45193 09/30/98 Ag-110M 6.97E-05 2.47E-04 1.07E-03 l AP 04 45193 09/30/98 Ba-140 1.71E-03 6.31E-03 2.60E-02 AP 04 45193 09/30/98 Be-7 0.12E+00 1.31E-02 2.49E-02
- AP 04 45193 09/30/98 Ce-141 2.77E-04 7.52E-04 2.47E-03 1 AP 04 45193 09/30/98 Ce-144 1.38E-03 8.25E-04 2.43E-03 AP 04 45193 09/30/98 Co-57 8.47E-05 1.01E-04 3.25E-04 AP 04 45193 09/30/98 Co-58 -2.24E-04 3.77E-04 1.68E-03 AP 04 45193 09/30/98 Co-60 -3.26E-05 2.60E-04 1.21E-03 AP 04 '45193 09/30/98 Cr-51 -4.35E-03 7.17E-03 2.78E-02 AP 04 45193 09/30/98 Cs-134 -4.15"-04 1.68E-04 8.35E-04 AP 04 45193 09/30/98 Cs-137 -1.46E-04 2.52E-04 1.09E-03 AP 04 45193 09/30/98 Fe-59 5.98E-04 8.80E-04 3.89E-03 AP 04 45193 09/30/98 I-131 9.17E-03 1.07E-02 3.73E-02 AP 04 45193 09/30/98 K-40 -1.80E-03 4.72E-03 1.96E-02 AP 04 45193 09/30/98 Mn-54 -1.61E-04 2.01E-04 9.64E-04 AP 04 45193 09/30/98 Ru-103 -4.37E-04 4.55E-04 2.10E-03 AP 04 45193 09/30/98 Ru-106 4.50E-04 1.56E-03 6.62E-03 AP 04 45193 09/30/98 Sb-124 -4.34E-04 1.09E-03 5.76E-03 l AP 04 45193 09/30/98 Se-75 -2.73E-04 3.18E-04 1.24E-03 !
AP 04 45193 09/30/98 Th-232 -8.52E-04 8.66E-04 4.00E-03 AP 04 45193 09/30/98 Zn-65 2.55E-04 4.32E-04 1.80E-03 AP 04 45193 09/30/98 Zr-95 -2.67E-04 2.67E-04 1.96E-03 AP 04 47052 12/30/98 Ag-110M 3.00E-04 4.09E-04 1.50E-03 ] AP 04 47052 12/30/98 Ba-140 4.21E-03 1.06E-02 4.27E-02 ' AP 04 47052 12/30/98 Be-7 6.39E-02 1.53E-02 4.54E-02
- AP 04 47052 12/30/98 Ce-141 -1.87E-04 1.27E-03 4.27E-03 AP 04 47052 12/30/98 Ce-144 -4.93E-04 1.34E-03 4.61E-03 AP 04 47052 12/30/98 Co-57 6.95E-05 1.93E-04 6.25E-04 AP 04 47052 12/30/98 Co-58 6.30E-04 7.53E-04 2.56E-03 AP 04 47052 12/30/98 Co-60 0.00E+00 2.11E-04 1.09E-03 AP 04 47052 12/30/98 Cr-51 -8.18E-03 1.34E-02 5.01E-02 AP 04 47052 12/30/98 Cs-134 -5.35E-04 2.86E-04 1.27E-03 AP 04 47052 12/30/98 Cs-137 -3.58E-04 4.00E-04 1.68E-03 AP 04 47052 12/30/98 Fe-59 -5.25E-04 1.60E-03 8.43E-03 AP 04 47052 12/30/98 I-131 2.04E-02 3.86E-02 0.13E+00 AP 04 47052 12/30/98 K-40 -7.91E-03 5.12E-03 2.45E-02 AP 04 47052 12/30/98 Mn-54 8.24E-04 4.69E-04 '1.39E-03 AP 04 47052 12/30/98 Ru-103 -7.35E-04 8.58E-04 3.61E-03 AP 04 47052 12/30/98 Ru-106 -5.90E-03 3.86E-03 1.70E-02 AP 04 47052 12/30/98 Sb-124 4.00E-03 2.13E-03 5.39E-03 AP 04 47052 12/30/98 Se-75 1.78E-04 4.60E-04 1.61E-03 AP 04 47052 12/30/98 Th-232 2.80E-04 1.39E-03 5.24E-03 AP 04 47052 12/30/98 Zn-65 2.19E-03 1.21E-03 3.50E-03 AP 04 47052 12/30/98 Zr-95 4.39E-04 1.27E-03 4.63E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I l
)
Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 05 41858 04/01/98 Ag-110M -1.76E-04 4.91E-04 2.07E-03 AP 05 41858 04/01/98 Ba-140 1.13E-02 3.24E-02 0.12E+00 AP 05 41858 04/01/98 Be-7 6.88E-02 1.68E-02 4.82E-02
- AP 05 41858 04/01/98 Ce-141 -1.98E-03 1.16E-03 4.71E-03 AP 05 41858 04/01/98 Ce-144 -9.37E-04 1.14E-03 4.20E-03 AP 05 41858 04/01/98 Co-57 -1.74E-04 1.27E-04 4.97E-04 AP 05 41858 04/01/98 Co-58 0.00E+00 5.11E-04 2.16E-03 AP 05 41858 04/01/98 Co-60 3.80E-05 2.86E-04 1.29E-03 AP 05 41858 04/01/98 Cr-51 4.35E-03 1.56E-02 5.62E-02 AP 05 41858 04/01/98 Cs-134 6.87E-04 3.80E-04 8.21E-04 AP 05 41858 04/01/98 Cs-137 -1.76E-04 3.30E-04 1.40E-03 AP 05 41858 04/01/98 Fe-59 -1.65E-03 2.23E-03 1.22E-02 AP 05 41858 04/01/98 I-131 4.63E-03 0.12E+00 0.46E+00 AP 05 41858 04/01/98 K-40 -2.45E-03 4.63E-03 2.04E-02 AP 05 41858 04/01/98 Mn-54 -3.16E-04 3.46E-04 1.52E-03 AP 05 41858 04/01/98 Ru-103 1.61E-03 8.75E-04 2.48E-03 l AP 05 41858 04/01/98 Ru-106 -1.71E-03 2.96E-03 1.28E-02 AP 05 41858 04/01/98 Sb-124 0.00E+00 1.44E-03 7.38E-03 AP 05 41858 04/01/98 Se-75 5.26E-04 4.55E-04 1.50E-03 AP 05 41858 04/01/98 Th-232 2.29E-04 9.73E-04 3.97E-03 AP 05 41858 04/01/98 Zn-65 7.95E-04 9.57E-04 3.45E-03 AP 05 41858 04/01/98 Zr-95 4.10E-04 1.03E-03 3.98E-03 AP 05 43094 07/01/98 Ag-110M -3.24E-04 2.92E-04 1.57E-03 AP 05 4336 07/01/98 Ba-140 -6.63E-04 4.64E-03 2.41E-02 AP 05 43091 07/01/98 Be-7 0.11E+00 1.28E-02 2.42E-02
- AP 05 43094 07/01/98 Ce-141 4.59E-04 6.80E-04 2.23E-03 AP 05 43094 07/01/98 Co-144 0.00E+00 8.54E-04 2.99E-03 AP 05 43094 07/01/98 Co-57 1.45E-04 1.02E-04 3.10E-04 AP 05 43094 07/01/98 Co-58 -1.30E-04 4.17E-04 1.82E-03 AP 05 43094 07/01/98 Co-60 0.00E+00 3.73E-04 1.64E-03 AP 05 43094 07/01/53 Cr-51 -3.07E-03 7.10E-03 2.79E-02 '
AP 05 43094 07/01/98 Cs-134 -6.17E-04 2.91E-04 1.37E-03 AP 05 43094 07/01/98 Cs-137 5.62E-05 9.73E-05 4.55E-04 i AP 05 43094 07/01/98 Fe-59 -9.30E-04 8.70E-04 6.56E-03 l AP 05 43094 07/01/98 I-131 -1.17E-03 1.36E-02 5.25E-02 AP 05 43094 07/01/98 K-40 -4.59E-03 3.93E-03 1.94E-02 AP 05 43094 07/01/98 Mn-54 -5.33E-05 2.89E-04 1.20E-03 AP 05 43094 07/01/98 Ru-103 1.26E-04 4.93E-04 1.98E-03 AP 05 43094 07/01/98 Ru-106 -6.07E-04 2.03E-03 9.18E-03 AP 05 43094 07/01/98 Sb-124 -8.45E-04 8.02E-04 6.02E-03 AP 05 43094 07/01/98 Se-75 -4.43E-04 2.98E-04 1.27E-03 AP 05 43094 07/01/98 Th-232 -1.24E-03 1.14E-03 5.10E-03 AP 05 43094 07/01/98 Zn-65 -1.78E-03 8.90E-04 4.45E-03 AP 05 43094 07/01/98 Zr-95 5.42E-04 7.38E-04 2.71E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) ( ___.- ______ _________________________________________________________pCi/cu.m) AP 05 45194 09/30/98 Ag-110M 3.22E-04 5.18E-04 1.90E-03 AP 05 45194 09/30/98 Ba-140 1.39E-02 1.09E-02 3.54E-02 AP 05 45194 09/30/98 0.11E+00 Be-7 1.51E-02 3.94E-02
- AP 05 45194 09/30/98 Ce-141 -5.38E-04 7.61E-04 2.84E-03 AP 05 45194 09/30/98 Ce-144 1.52E-03 1.14E-03 3.49E-03 AP 05 45194 09/30/98 Co-57 1.03E-04 1.42E-04 4.60E-04 AP 05 45194 09/30/98 Co-58 -6.08E-04 7.24E-04 3.00E-03 AP 05 45194 09/30/98 Co-60 -7.75E-04 3.47E-04 2.09E-03 AP 05 45194 09/30/98 Cr-51 9.85E-04 7.43E-03 2.82E-02 AP 05 45194 09/30/98 Cs-134 -1.04E-04 2.49E-04 9.94E-04 AP 05 45194 09/30/98 Cs-137 -4.94E-04 3.57E-04 1.65E-03 i
AP 05 45194 09/30/98 Fe-59 1.90E-03 2.19E-03 8.20E-03 AP 05 45194 09/30/98 I-131 1.11E-02 1.76E-02 6.21E-02 AP 05 45194 09/30/98 K-40 -3.56E-03 4.32E-03 2.11E-02 AP 05 45194 09/30/98 Mn-54 2.87E-04 3.30E-04 1.16E-03 AP 05 45194 09/30/98 Ru-103 -4.08E-04 6.62E-04 2.89E-03 AP 05 45194 09/30/98 Ru-106 -9.16E-04 2.42E-03 1.10E-02 AP 05 45194 09/30/98 Sb-124 -9.82E-04 8.79E-04 6.75E-03 AP 05 45194 09/30/98 Se-75 6.99E-04 3.88E-04 1.18E-03 AP 05 45194 09/30/98 Th-232 -1.47E-03 1.22E-03 5.68E-03 AP 05 45194 09/30/98 Zn-65 -2.15E-03 1.33E-03 5.98E-03 AP 05 45194 09/30/98 Zr-95 -2.02E-04 9.29E-04 4.16E-03 AP 05 47053 12/29/98 Ag-110M -2.83E-04 4.33E-04 1.94E-03 AP 05 47053 12/29/98 Ba-140 -5.23E-03 4.68E-03 3.59E-02 AP 05 47053 12/29/98 *Be-7 0.12E+00 1.32E-02 2.74E-02
- AP 05 47053 12/29/98 Ce-141 3.33E-04 7.81E-04 2.64E-03 AP 05 47053 12/29/98 Ce-144 -1.46E-03 8.32E-04 3.39E-03 AP 05 47053 12/29/98 Co-57 -7.56E-06 8.85E-05 3.25E-04 AP 05 47053 12/29/98 Co-58 -4.79E-04 4.44E-04 2.16E-03 AP- 05 47053 12/29/98 Co-60 0.00E+00 2.21E-04 1.15E-03 AP 05 47053 12/29/98 Cr-51 -5.21E-03 9.42E-03 3.70E-02 AP 05 47053 12/29/98 Cs-134 2.45E-05 1.41E-04 6.41E-04 AP 05 47053 12/29/98 Cs-137 -2.31E-04 2.23E-04 ,1.10E-03 AP 05 47053 12/29/98 Fe-59 2.69E-04 2.02E-03 9.10E-03 AP 05 47053 12/29/98 I-131 -1.44E-02 1.92E-02 8.76E-02 AP 05 47053 12/29/98 K-40 -1.41E-03 4.58E-03 1.98E-02 AP 05 47053 12/29/98 Mn-54 1.39E-04 3.11E-04 1.17E-03 AP 05 47053 12/29/98 Ru-103 1.11E-04 5.85E-04 2.37E-03 AP 05 47053 12/29/98 Ru-106 3.25E-03 2.30E-03 7.55E-03 AP 05 47053 12/29/98 Sb-124 -9.47E-04 8.99E-04 6.75E-03 AP 05 47053 12/29/98 Se-75 1.14E-04 3.71E-04 1.33E-03 AP 05 47053 12/29/98 Th-232 -7.39E-04 7.15E-04 3.85E-03 AP 05 47053 12/29/98 Zn-65 3.63E-04 6.67E-04 2.67E-03 AP 05 47053 12/29/98 Zr-95 9.49E-04 8.93E-04 3.02E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of.1998 Data SAMPLE CONC. STD DEV. MDC TYPE- STA. LSN END DATE NUCLIDE .(pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 06 41859 04/01/98 Ag-110M 3.21E-04 3.85E-04 1.42E-03 l AP 06 41859 04/01/98 Ba-140 1.55E-02 .2.10E-02 8.31E-02 1 AP 06 41859 04/01/98 Be-7 9.66E-02 1.41E-02 2.93E-02
- AP 06 41859 04/01/98 Ce-141 -1.26E-03 9.72E-04 3.98E-03 AP 06 41859 04/01/98 Ce-144 -3.48E-04 8.38E-04 3.16E-03 AP 06 41859 04/01/98 Co-57 -1.11E-04 1.18E-04 4.51E-04 AP 06 41859 04/01/98 Co-58 3.63E-04 4.92E-04 1.85E-03 AP 06 41859 04/01/98 Co-60 0.00E+00 4.19E-04 1.84E-03 AP 06 41859 04/01/98 Cr-51 -2.77E-03 1.45E-02 5.55E-02 AP 06 41859 04/01/98 Cs-134 -2.43E-04 2.43E-04 1.14E-03 AP -06 41859 04/01/98 Cs-137 -9.42E-05 2.11E-04 1.01E-03 AP 06 41859 04/01/98 Fe-59 -7.42E-04 2.26E-03 1.19E-02 AP 06 41859 04/01/98 I-131 0.00E+00 8.68E-02 0.35E+00 AP 06 41859 04/01/98 K-40 -5.12E-03 4.45E-03 2.20E-02 AP 06 41859 04/01/98 Mn-54 -3.13E-05 2.40E-04 1.10E-03 AP 06 41859 04/01/98 Ru-103 1.27E-04 9.43E-04 3.75E-03 AP 06 41859 04/01/98 Ru-106 4.55E-03 3.02E-03 9.80E-03 AP 06 41859 04/01/98 Sb-124 2.46E-04 1.61E-03 8.19E-03 AP 06 41859 04/01/98 Se-75 0.00E+00 3.82E-04 1.44E-03 AP 06 41859 04/01/98 Th-232 -7.03C-04 9.26E-04 4.49E-03 AP 06 41859 04/01/98 Zn-65 4.86E-04 8.86E-04 3.45E-03 AP 06 41859 04/01/98 Zr-95 6.10E-04 6.97E-04 2.61E-03 AP 06 43095 07/01/98 Ag-110M -6.49E-04 3.88E-04 2.09E-03 AP 06 43095 07/01/98 Ba-140 -9.82E-03 7.44E-03 4.01E-02 AP 06 43095 ~07/01/98 Be-7 8.12E-02 1.35E-02 3.07E-02
- AP 06 43095 07/01/98 Ce-141 -1.07E-03 6.76E-04 2.77E-03 AP 06 43095 07/01/98 Ce-144 2.74E-04 1.11E-03 3.74E-03 AP '06 43095 07/01/98 Co-57 8.38E-06 1.16E-04 4.08E-04 AP 06 43095 07/01/98 Co-58 -9.94E-05 3.91E-04 1.81E-03 AP Oi 43095 07/01/98 Co-60 -3.46E-04 2.44E-04 1.51E-03 AP 06 43095 07/01/98 Cr-51 1.01E-02 9.78E-03 3.26E-02 AP 06 43095 07/01/98 Cs-134 2.74E-05 2.27E-04 9.54E-04 AP 06 43095 07/01/98 Cs-137 -9.71E-05 2.17E-04 1.05E-03 AP 06 43095 07/01/98 Fe-59 -6.62E-04 2.19E-03 1.03E-02 AP 06 43095 07/01/98 I-131 1.38E-03 1.46E-02 5.65E-02 AP 06 43095 07/01/98 K-40 1.73E-03 5.41E-03 2.22E-02 AP 06 43095 07/01/98 Mn-54 1.53E-04 1.96E-04 7.57E-04 AP 06 43095 07/01/98 Ru-103 -1.05E-03 6.76E-04 3.20E-03 AP 06 43095 07/01/98 Ru-106 -1.80E-03 2.21E-03 1.08E-02 AP 06 43095 07/01/98 Sb-124 -7.65E-04 1.55E-03 8.25E-03 AP ~06 43095 07/01/98 Se-75 -2.04E-04 3.69E-04 1.45E-03 AP 06 43095 07/01/98 Th-232 2.06E-03 1.22E-03 3.65E-03 l- AP 06 43095 07/01/98 Zn-65 -6.76E-04 6.44E-04 3.46E-03 l
AP 06 43095 07/01/98 Zr-95 7.12E-04 9.59E-04 3.45E-13
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
t
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Sunnary of 1998 Data SAMPLE CONC. STD DEV. MDC
, TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m)
AP 06 45195 09/30/98 Ag-110M -1.64E-04 3.38E-04 1.59E-03 AP 06 45195 09/30/98 Ba-140 -5.81E-03 5.81E-03 3.12E-02 AP 06 45195 09/30/98 Be-7 9.37E-02 1.36E-02 3.79E-02
- AP 06 45195 09/30/98 Ce-141 -4.18E-04 7.86E-04 2.86E-03 AP 06 45195 09/30/98 Ce-144 1.01E-03 1.14E-03 3.62E-03 AP 06 45195 09/30/98 Co-57 -8.31E-05 1.18E-04 4.38E-04 AP 06 45195 09/30/98 Co-58 -6.17E-04 4.94E-04 2.29E-03 AP 06 45195 09/30/98 Co-60 1.31E-04 2.58E-04 1.09E-03 AP 06 45195 09/30/98 Cr-51 5.32E-03 8.42E-03 2.95E-02 AP 06 45195 09/30/98 Cs-134 -5.36E-04 1.98E-04 1.06E-03 AP 06 45195 09/30/98 Cs-137 8.70E-05 3.37E-04 1.31E-03 AP 06 45195 09/30/98 Fe-59 -1.37E-03 2.06E-03 9.93E-03 AP 06 45195 -09/30/98 I-131 3.17E-03 1.60E-02 5.92E-02 AP 06 45195 09/30/98 K-40 0.00E+00 4.72E-03 1.96E-02 AP 06 45195 09/30/98 Mn-54 -5.81E-04 2.97E-04 1.48E-03 AP 06 45195 09/30/98 Ru-103 -9.98E-05 6.74E-04 2.70E-03 AP 06 45195 09/30/98 Ru-106 -5.40E-04 2.09E-03 9.40E-03 AP 06 45195 09/30/98 Sb-124 -4.90E-04 1.23E-03 6.50E-03 AP 06 45195 09/30/98 Se-75 1.67E-04 4.30E-04 1.51E-03 AP 06 45195 09/30/98 Th-232 2.76E-03 1.36E-03 3.94E-03 AP 06 45195 09/30/98 Zn-65 -1.11E-04 8.25E-04 3.48E-03 AP 06 45195 09/30/98 Zr-95 5.54E-04 7.55E-04 2.77E-03 AP 06 47054 12/29/98 Ag-110M 3.27E-04 4.46E-04 1.64E-03 AP 06 47054 12/29/98 Ba-140 -5.71E-03 5.10E-03 3.92E-02 AP 06 47054 12/29/98 Be-7 7.67E-02 1.33E-02 3.05E-02
- AP 06 47054 12/29/98 Ce-141 1.93E-03 1.05E-03 3.02E-03 AP 06 47054 12/29/98 Ce-144 -2.20E-03 9.33E-04 3.95E-03 AP 06 47054 12/29/98 Co-57 -2.53E-05 9.46E-05 3.57E-04 AP 06 47054 12/29/98 Co-58 -2.64E-04 3.46E-04 1.85E-03 AP 06 47054 12/29/98 Co-60 -1.71E-04 2.96E-04 1.59E-03 AP 06 47054 12/29/98 Cr-51 9.75E-03 9.02E-03 3.03E-02 AP 06 47054 12/29/98 Cs-134 -1.09E-04 1.88E-04 9.14E-04 AP 06 47054 -12/29/98 Cs-137 9.58E-05 3.18E-04 1.26E-03 AP 06 47054 12/29/98 Fe-59 1.18E-03 1.99E-03 8.30E-03 AP 06 47054 12/29/98 I-131 -1.26E-02 2.83E-02 0.12E+00 AP 06 47054 12/29/98 K-40 9.58E-04 5.18E-03 2.09E-02 AP 06 47054 12/29/98 Mn-54 -6.13E-05 1.79E-04 9.36E-04 AP 06 47054 12/29/98 Ru-103 -3.31E-05 7.55E-04 3.06E-03 AP 06 47054 12/29/98 Ru-106 -3.00E-03 2.44E-03 1.21E-02 AP 06 47054 12/29/98 Sb-124 0.00E+00 1.42E-03 7.33E-03 AP 06 47054 12/29/98 Se-75 -3.37E-04 4.08E-04 1.61E-03 AP 06 47054 12/29/98 Th-232 4.57E-04 1.03E-03 4.03E-03 AP 06 47054 12/29/98 Zn-65 1.70E-04 4.08E-04 1.97E-03 AP 06 47054 12/29/98 Zr-95 1.34E-04 1.11E-03 4.35E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
}
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) ] AP 07 41860 04/01/98 Ag-110M 2.37E-04 6.07E-04 2.30E-03 AP 07 41860 04/01/98 Ba-140 -3.44E-02 1.99E-02 0.13E+00 AP 07- 41860 04/01/98 Be-7 9.28E-02 1.58E-02 3.69E-02
- AP 07 41860 04/01/98 Ce-141 -7.51E-04 1.41E-03 5.13E-03 AP 07 41860 04/01/98 Ce-144 3.14E-04 1.34E-03 4.50E-03 AP 07 41860 04/01/98 Co-57 -2.91E-05 1.15E-04 4.29E-04 AP 07 41860 04/01/98 Co-58 1.36E-04 4.79E-04 2.07E-03 AP 07 41860 04/01/98 Co-60 -1.91E-04 1.79E-04 1.35E-03 AP 07 41860 04/01/98 Cr-51 -4.36E-03 1.48E-02 5.82E-02 AP 07 41860 04/01/98 Cs-134 4.10E-04 2.75E-04 8.59E-04 AP 07 41860 04/01/98 Cs-137 -2.29E-04 3.37E-04 1.51E-03 AP 07 41860 04/01/98 Fe-59 -1.65E-03 1.17E-03 1.22E-02 )
AP 07 41860 04/01/98 I-131 0.32E+00 0.13E+00 0.36E+00 l AP 07 41860 04/01/98 K-40 -1.19E-03 6.10E-03 2.55E-02 AP 07 41860 04/01/98 Mn-54 9.34E-05 3.05E-04 1.24E-03 AP 07 41860 04/01/98 Ru-103 -1.66E-04 1.10E-03 4.50E-03 AP 07 41860 04/01/98 Ru-106 4.09E-03 2.89E-03 9.49E-03 AP 07 41860 04/01/98 Sb-124 -2.73E-03 2.52E-03 1.36E-02 AP 07 41860 04/01/98 Se-75 -1.12E-03 4.92E-04 2.14E-03 AP 07 41860 04/01/98 Th-232 -1.24E-03 1.26E-03 5.81E-03 AP 07 41860 04/01/98 Zn-65 -5.92E-04 8.88E-04 4.28E-03 AP 07 41860 04/01/98 Zr-95 -8.28E-04 9.52E-04 5.12E-03 AP 07 43096 07/01/98 Ag-110M 5.39E-04 5.90E-04 2.04E-03 AP 07 43096 07/01/98 Ba-140 -4.11E-03 3.68E-03 2.82E-02 AP 07 43096 07/01/98 Be-7 8.64E-02 1.32E-02 2.74E-02
- AP 07 43096 07/01/98 Ce-141 -1.15E-04 7.78E-04 2.79E-03 AP 07 43096 07/01/98 Ce-144 -6.67E-04 1.00E-03 3.76E-03 AP 07 43096 07/01/98 Co-57 -6.40E-05 1.32E-04 4.82E-04 AP 07 43096 07/01/98 Co-58 1.08E-04 2.54E-04 1.20E-03 AP 07 43096 07/01/98 Co-60 3.31E-04 3.83E-04 1.43E-03 AP 07 43096 07/01/98 Cr-51 1.27E-02 7.66E-03 2.35E-02 AP 07 43096 07/01/98 Cs-134 1.49E-04 2.49E-04 9.32E-04 AP 07 43096 07/01/98 Cs-137 0.00E+00 2.58E-04 1.14E-03 AP 07 43096 07/01/98 Fe-59 2.89E-04 2.17E-03 9.78E-03 AP 07 43096 07/01/98 I-131 8.07E-03 1.36E-02 5.01E-02
'AP 07 43096 07/01/98 K-40 -1.90E-03 4.98E-03 2.25E-02 AP 07 43096 07/01/98 Mn-54 0.00E+00 3.05E-04 1.29E-03 AP 07 43096 07/01/J8 Ru-103 -9.02E-04 8.34E-04 3.63E-03 AP 07 43096 07/01/98 Ru-106 2.36E-03 2.31E-03 8.37E-03 AP 07 43096 07/01/98 Sb-124 -1.05E-03 9.37E-04 7.20E-03 ;
AP 07 43096 07/01/98 Se-75 5.85E-05 3.51E-04 1.31E-03 AP 07 43096 07/01/98 Th-232 -8.24E-04 1.20E-03 5.46E-03 AP 07 43096 07/01/98 Zn-65 -3.69E-04 3.45E-04 2.61E-03 AP 07 43096 07/01/98 Zr-95 -1.35E-03 1.31E-03 5.98E-03
*' Radioactivity detected in sample (i .e. , CONC > 3 STD. DEV.)
I Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) AP 07 45196 09/30/98 Ag-110M -1.34E 04 4.32E-04 1.88E-03 AP 07 45196 09/30/98 Da-140 -1.47E-03 5.34E-03 2.80E-02 AP 07 45196 09/30/98 Be-7 5.96E-02 1.16E-02 2.67E-02
- AP 07 45196 09/30/98 Ce-141 -6.08E-04 7.23E-04 2.72E-03 AP 07 45196 09/30/98 Ce-144 -6.52E-05 7.63E-04 2.80E-03 AP 07 45196 09/30/98 Co-57 2.40E-05 1.01E-04 3.53E-04 AP 07 45196 09/30/98 Co-58 3.5EE-04 2.77E-04 7.90E-04 AP 07 45196 09/30/98 Co-60 1.26E-04 1.88E-04 8.46E-04 AP 07 45196 09/30/98 Cr-51 2.26E-03 7.27E-03 2.69E-02 AP 07 45196 09/30/98 Cs-134 -3.15E-04 2.94E-04 1.31E-03 AP 07 45196 09/30/98 Cs-137 -9.32E-OS 2.47E-04 1.12E-03 AP 07 45196 09/30/98 Fe-59 -1.03E-03 9.61E-04 7.25E-03 AP 07 45196 09/30/98 I-131 -5.82E-03 1.36E-02 5.57E-02 AP 07 45196 09/30/98 K-40 2.61E-03 5.85E-03 2.21E-02 AP 07 45196 09/30/98 Mn-54 -2.94E-05 2.26E-04 1.03E-03 AP 07 45196 09/30/98 Ru-103 -5.58E-04 6.46E-04 2.86E-03 AP 07 45196 09/30/98 Ru-106 2.06E-10 2.44E-03 1.04E-02 AP 07 45196 09/30/90 Sb-124 1.21E-03 2.37E-03 9.30E-03 AP 07 45196 09/50/98 Se-75 5.58E-04 3.58E-04 1.13E-03 AP 07 45196 09/30/98 Th-232 4.48E-04 1.03E-03 4.09E-03 AP 07 45196 09/30/98 Zn-65 2.18E-04 7.36E-04 3.07E-03 AP 07 45196 09/30/98 Zr-95 5.13E-04 5.27E-04 1.90E-03 AP 07 47055 12/29/98 Ag-110M -2.09E-04 1.81E-04 1.41E-03 AP 07 47055 12/29/98 Ba-140 -3.868-03 9.70E-03 5.12E-02 AP 07 47055 12/29/98 Be-7 7.055-02 1.15E-02 2.08E-02
- AP 07 47055 12/29/98 Ce-141 4.128-04 9.66E-04 3.27E-03 AP 07 47055 12/29/98 Ce-144 1.07E-03 1.19E-03 3.80E-03 AP 07 47055 12/29/98 Co-57 -6.61E-05 1.37E-04 4.98E-04 AP 07 47055 12/29/98 Co-58 6.30E-04 4.26E-04 1.19E-03 AP 07 47055 '12/29/98 Co-60 -1.44E-04 3.06E-04 1.63E-03 AP 07 47055 12/29/98 Cr-51 -7.33E-03 1.07E-02 4.32E-02 AP 07 47055 12/29/98 Cs-134 3.03E-05 2.42E-04 9.85E-04 AP 07 47055 12/29/98 'Cs-137 2.21E-04 3.01E-04 1.14E-03 AP 07 47055 12/29/98 Fe-59 -1.32E-03 1.24E-03 9.32E-03 AP 07 47055 12/29/98 I-131 1.05E-02 3.08E-02 0.12E+00 AP 07 47055 12/29/98 K-40 -3.61E-03 4.62E-03 2.26E-02 AP 07 47055 12/29/98 Mn-54 -1.71E-04 2.25E-04 1.20E-03 AP 07 47055 12/29/98 Ru-103 -1.01E-03 7.15E-04 3.54E-03 AP 07 47055 12/29/98 Ru-106 2.01E-03 2.46E-03 9.33E-03 AP 07 47055 12/29/98 Sb-124 1.16E-03 1.94E-03 7.97E-03 AP 07 47055 12/29/98 Se-75 5.14E-04 3.44E-04 1.09E-03 AP 07 47055 12/29/98 Th-232 -9.10E-04 1.23E-03 5.60E-03 AP 07- 47055 12/29/98 Zn-65 -7.64E-04 1.04E-03 4.75E-03 AP 07 47055 12/29/98 Zr-95 0.00E+00 1.21E-03 5.12E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i Seabrook Nuclear Power Station Radiological' Environmental Monitoring Program I Summary of 1998 Data l SAMPLE CONC. STD DEhT. MDC i TYPE. STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) .AP 08 41861 04/01/98 Ag-110M 4.36E-04 3.95E-04 1.33E-03 AP , 08 41861 04/01/98 Ba-140 9.00E-03 1.94E-02 8.17E-02 AP 08 41861 04/01/98 Be-7 8.81E-02 1.66E-02 4.44E-02 * ; AP 08 '41861 04/01/98 Ce-141 -7.49E-04 1.41E-03 5.04E-03 AP 08 41861 04/01/98- Ce-144 7.13E-05 9.10E-04 3.23E-03 AP 08 41861 04/01/98 Co-57 3.52E-05 1.43E-04 4.81E-04. -AP 08 41861 04/01/98 Co-58 1.10E-04 6.39E-04 2.48E-03 AP 08 41861 04/01/98 Co-60 5.64E-04 3.09E-04 7.3SE-04 AP .08 41861 04/01/98 Cr-51 2.02E-02 1.46E-02 4.71E-02 AP 08 41861 04/01/98 Cs-134 -7.55E-05 3.11E-04 1.26E-03 AP 08 41861 04/01/98 Cs-137 -2.61E-04 2.61E-04 1.23E-03 AP 08 41861 04/01/98 Fe-59 1.64E-03 2.13E-03 8.48E-03 AP 08 41861 04/01/98 _I-131 -5.54E-02 0.14E+00 0.53E+00 AP 08 41861 04/01/98 K-40 5.96E-03 5.68E-03 2.03E-02 AP 08 41861 04/01/98 Mn-54 2.84E-05 2.97E-04 1.20E-03 AP 08 41861 04/01/98 Ru-103 0.00E+00 9.07E-04 3.65E-03 AP 08 41861 04/01/98 Ru-106 0.00E+00 2.93E-03 1.19E-02 AP 08 41861 04/01/98 Sb-124 -1.06E-03 9.51E-04 7.30E-03 AP 08 41861 04/01/98 Se-75 3.81E-04 4.46E-04 1.51E-03 AP 08 41861 04/01/98 Th-232 1.21E-03 1.06E-03 3.65E-03 AP 08 41861 04/01/98 Zn-65 -1.57E-04 7.74E-04 3.41E-03 AP 08 41861 04/01/98 Zr 3.05E-04 8.80E-04 3.56E-03 AP 08 43097 07/01/98 Ag-110M -1.70E-04 3.50E-04 1.64E-03 AP . 08 43097 07/01/98 Ba-140 1.35E-03 6.11E-03 2.69E-02 AP 08 43037 07/01/98 Be-7 9.22E-02 1.28E-02 2.91E-02
- AP 08 43097 07/01/98 Ce-141 -4.35E-04 7.61E-04 2.81E-03 AP 08 43097 07/01/98 Ce-144 2.99E-03 1.13E-03 2.92E-03 AP 08 43097 07/01/98 Co-57 2.67E-04 1.37E-04 3.90E-04 AP 08 43097 07/01/98 Co-58 5.26E-04 4.03E-04 1.28E-03 AP 08 43097 07/01/98 Co-60 1.93E-04 2.52E-04 1.00E-03 AP 08 43097 07/01/98 Cr-51 -6.63E-03 8.34E-03 3.36E-02 AP 08 43097 07/01/98 Cs-134 7.66E-05 2.30E-04 9.20E-04 AP 08 43097 07/01/98 Cs-137 -3.01E-05 2.60E-04 1.12E-03 AP 08 43097 07/01/98 Fe-59 4.04E-03 2.26E-03 6.16E-03 AP 08 43097 07/01/98 I-131 -10.0E-03 1.81E-02 7.09E-02 AP 08 43097 07/01/98 K-40 5.02E-03 5.89E-03 2.11E-02 AP 08 43097 07/01/98 Mn-54 2.66E-04 3.31E-04 1.16E-03 AP- 08 43097 07/01/98 Ru-103 4.49E-04 7.44E-04 2.69E-03 AP 08 43097 07/01/98 Ru-106 -1.68E-04 2.68E-03 1.12E-02 AP 08 43097 07/01/98 Sb-124 9.32E-04 1.40E-03 5.64E-03 AP 08' 43097 07/01/98 Se-75 -1.25E-05 4.46E-04 1.62E-03
.AP 08 43097 07/01/98 Th-232 -1.03E-03 9.26E-04 4.55E-03 AP 08 43097 07/01/98 Zn-65 4.20E-04 7.67E-04 2.98E-03 AP 08 43097 07/01/98- Zr-95 -1.64E-04 8.93E-04 3.70E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN EMD DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pC1/cu.m) AP 08 45197 09/30/98 Ag-110M -6.33E-04 3.78E-04 2.04E-03 AP 08 45197 09/30/98 Ba-140 0.00E+00 4.91E-03 2.51E-02 AP 08 45197 09/30/98 Be-7 9.88E-02 1.32E-02 2.73E-02
- AP 08 45197 09/30/98 Ce-141 1.09E-03 9.04E-04 2.79E-03 AP 08 45197 09/30/98 Ce-144 2.00E-04 9.87E-04 3.39E-03 AP 08 45197 09/30/98 Co-57 1.96E-04 1.30E-04 3.89E-04 AP 08 45197 09/30/98 Co-58 -3.39E-04 4.25E-04 2.03E-03 AP 08 45197 09/30/98 Co-60 1.68E-04 4.46E-04 1.81E-03 AP 08 45197 09/30/98 Cr-51 -1.17E-02 8.46E-03 3.55E-02 AP 08 45197 09/30/98 Cs-134 4.00E-04 3.28E-04 8.61E-04 AP 08 45197 09/30/98 Cs-137 2.84E-04 2.84E-04 1.02E-03 AP 08 45197 09/30/98 Fe-59 -1.03E-03 9.63E-04 7.27E-03 AP 08 45197 09/30/98 I-131 3.39E-02 1.88E-02 5.71E-02 AP 08 45197 09/30/98 K-40 1.13E-03 5.57E-03 2.19E-02 AP 08 45197 09/30/98 Mn-54 -2.38E-04 2.66E-04 1.28E-03 AP 08 45197 09/30/98 Ru-103 6.05E-04 6.91E-04 2.43E-03
) AP 08 45197 09/30/98 Ru-106 1.85E-03 1.73E-03 6.22E-03 AP 08 45197 09/30/98 Sb-124 0.00E+00 1.28E-03 6.63E-03 AP 08 45197 09/30/98 Se-75 1.80E-04 3.73E-04 1.32E-03 AP 08 45197 09/30/98 Th-232 6.02E-04 9.94E-04 3.81E-03 AP 08 45197 09/30/98 Zn-65 -1.40E-03 7.79E-04 4.18E-03 AP 08 45197 09/30/98 Zr-95 3.47E-04 8.67E-04 3.36E-03 AP 08 47056 12/30/98 Ag-110M 4.18E-05 4.37E-04 1.76E-03 AP 08 47056 12/30/98 Ba-140 1.90E-03 8.60E-03 3.79E-02 AP 08 47056 12/30/98 Be-7 4.60E-02 1.22E-02 3.89E-02
- AP 08 47056 12/30/98 Ce-141 -6.09E-04 9.82E-04 3.55E-03 AP 08 47056 12/30/98 Ce-144 6.18E-04 1.12E-03 3.69E-03 AP 08 47056 12/30/98 Co-57 4.24E-05 1.24E-04 4.21E-04 AP 08 47056 12/30/98 Co-58 9.14E-04 4.96E-04 1.34E-03 AP 08 47056 12/30/98 Co-60 2.81E-04 3.63E-04 1.36E-03 AP 08 47056 12/30/98 Cr-51 -2.90E-03 1.05E-02 3.96E-02 AP 08 47056 12/30/98 Cs-134 -2.24E-04 2.81E-04 1.24E-03 AP 08 47056 12/30/98 Cs-137 -1.74E-04 2.47E-04 1.14E-03 AP 08 47056 12/30/98 Fe-59 -5.12E-04 2.52E-03 1.11E-02 AP 08 47056 12/30/98 I-131 -2.70E-02 2.82E-02 0.12E+00 AP 08 47056 12/30/98 K-40 2.99E-03 5.17E-03 1.96E-02 AP 08 47056 12/30/98 Mn-54 2.86E-04 2.87E-04 9.84E-04 AP 08 47056 12/30/98 Ru-103 1.89E-04 6.59E-04 2.58E-03 AP 08 47056 12/30/98 Ru-106 6.20E-03 3.12E-03 9.33E-03 AP 08 47056 12/30/98 Sb-124 1.06E-03 1.44E-03 5.70E-03 AP 08 47056 12/30/98 Se-75 4.42E-04 4.28E-04 1.42E-03 AP 08 47056 12/30/98 Th-232 -2.73E-04 1.14E-03 4.70E-03 AP 08 47056 12/30/98 Zn-65 1.88E-04 8.95E-04 3.56E-03 AP 08 47056 12/30/98 Zr-95 -1.71E-04 9.30E-04 3.85E-03
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
F. ) i Seabrook Nuclear Power Station Radiological Environmental Monitoring System Surnmary of 1998 Data SAMPLE CONC. STD DEV. MDC l TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) l 1 Radiciodine (Charcoal Filters) I CF 01- 40284 01/07/98 I-131 1.12E-02 9.38E-03 3.17E-02 CF 01 40359 01/14/98 I-131 7.15E-03 1.08E-02 3.84E-02 CF 01 40524 01/21/98 I-131 -1.94E-02 8.26E-03 3.53E-02 CF 01 40613 01/28/98 I-131 -1.47E-09 7.84E-03 3.00E-02 CF 01 40684 02/04/98 I-131 -2.29E-02 9.29E-03 4.52E-02 I CF 01 40850. 02/11/98 I-131 1.87E-02 9.68E-03 3.06E-02 CF 01 40918 02/18/98 I-131 3.07E-03 3.11E-02 4.33E-02 CF 01 41030 02/25/98 I-131 5.15E-03 7.48E-03 2.'72E-02 CF 01 41207 03/04/98 I-131 -6.47E-03 8.28E-03 3.24E-02 CF 01 41289 '03/11/98 I-131 5.79E-03 9.92E-03 3.51E-02 CF 01 41402 03/18/98 I-131 3.68E-03 9.01E-03 3.33E-02 CF 01 41500 03/25/98 I-131 6.44E-03 9.20E-03 3.22E-02 CF 01 41569 04/01/98 I-131 2.12E-03 1.08E-02 3.91E-02 CF 01 41609 04/08/98 I-131 1.20E-02 9.74E-03 3.29E-02 CF' 01 41811 04/15/98 I-131 7.27E-03 1.04E-02 3.65E-02 CF 01 41953 04/22/98 I-131 -1.09E-02 1.04E-02 4.11F-02 CF 01 41980 04/29/98 I-131 4.73E-03 8.48E-03 3.07E-02 i CF 01 42119 05/06/98 I-131 -4.23E-03 1.05E-02 3.91E-02 CF 01 42211 05/12/98 I-131 5.59E-03 1.00E-02 3.63E-02 CF 01 42323 05/20/98 I-131 -5.71E-03 8.57E-03 3.36E-02 CF 01 42421 05/27/98 I-131 1.05E-02 8.29E-03 2.79E-02 CF 01 42531 06/03/98 I-131 -7.61E-03 8.59E-03 3.40E-02 CF 01 42609 06/10/98 I-131 0.00E+00 1.06E-02 4.10E-02 CF 01 42708 06/17/98 I-131 -7.06E-03 8.64E-03 3.55E-02 CF 01 42780 06/24/98 I-131 0.00E+00 1.02E-02 3.88E-02 CF 01 42898 07/01/98 I-131 -8.24E-03 1.01E-02 3.87E-02 CF .01 42988 07/08/98 I-131 -1.24E-03 7.96E-03 2.99E-02 CF 01 (3066 07/15/98 I-131~ -7.53E-03 8.65E-03 3.46E-02
'CF 01 43157 07/22/98 I-131. -2.91E-03 8.48E-03 3.27E-02 CF 01 43300 07/29/98 I-131 -4.45E-03 8.33E-03 3.53E-02 CF 01 43373 08/05/98 I-131 2.41E-03 1.10E-02 4.19E-02 Cr 01 43505 08/12/98 I-131 7.45E-03 1.04E-02 3.65E-02 CF 01 43639 08/19/98 I-131 0.00E+00 8.15E-03 3.04E-02 CF 01 43866 08/26/98 I-131 3.82E-04 9.64E-03 3.58E-02 CF- 03 44061 09/02/98 I-131 -1.27E-02 9.47E-03 3.68E-02 CF 01 44157 09/09/98 I-131 0.00E+00 1.08E-02 3.96E-02 CF 01 44260 09/16/98 I-131 -1.06E-02 9.12E-03 3.70E-02 CF 01 44346 09/23/98 I-131 -6.18E-03 9.35E-03 3.61E-02 CF 01 44651 09/30/98 I-131 -6.03E-03 9.63E-03 3.91E-02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE- STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m)
,CF 01 45067- 10/07/98 I-131 ~1.72E-03 1.13E-02 4.23E-02 CF 01 45091 10/14/98 I-131 0.00E+00 8.04E-03 3.03E-02 CF 01 45271 10/21/98 I-131 3.73E-03 9.14E-03 3.38E-02 CF 01 45405- 10/28/98 I-131 -9.74E-03 8.89E-03 3.64E-02 CF 01 45499 11/04/98' I-131- 6.00E-03 9.30E-03 3.29E-02 CF 01 45681 11/10/98 I-131 -4.39E-03 1.31E-02 4.77E-02 CF 01 45711 11/18/98- I-131 4.83E-03 6.96E-03 2.49E-02 CF 01 45841 11/25/98 I-131 0.00E+00 8.42E-03 3.09E-02 CF 01 46103 12/02/98 I-131 -1.03E-02 1.45E-02 5.48E-02 CF 01 46172 12/09/98 I-131 -1.'10E-02 1.44E-02 5.60E-02 CF '01 46119 12/16/98 I-131 -1.41E-03 7.85E-03 3.01E-02 CF- ' 01 - 46517 12/23/98 'I-131 -2.33E-03 9.31E-03 3.47E-02 CF 01 46582 12/29/98 I-131 1.47E-03 1.13E-02 4.07E-02 l
I i i l l 1
*
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
s:
d Seabrook Nuclear Power Station Radiological Environmental Monitoring System , Summary of 1998 Data i SAMPLE CONC. STD DEV. MDC 3 TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m)
l l
CF 02 40285 01/07/98 I-131 -7.80E-03 1.03E-02 3.91E-02 CF 02 40360 01/14/98 I-131 1.86E-02 8.70E-03 2.62E-02 i CF 02 40525 01/21/98 I-131 -3.80E-03 8.52E-03 3.30E-02 I CF 02 40614 01/28/98 I-131 1.70E-02 8.01E-03 2.44E-02 l CF 02 40685 02/04/98 I-131 -9.13E-03 1.04E-02 4.34E-02 CF 02 40851 02/11/98 I-131 3.82E-03 1.08E-02 3.96E-02 CF 02 40919 02/18/98 I-131 -2.82E-03 9.45E-03 4 C7E-02 CF 02 41031 02/25/98 I-131 1.98E-02 1.28E-02 4.20E-02 CF 02 41208 03/04/98 I-131 1.82E-02 1.06E-02 3.45E-02 CF 02 41290 03/11/98 I-131 1.78E-03 1.16E-02 4.26E-02 CF 02 41403 03/18/98 I-131 1.82E-03 1.07E-02 3.97E-02 ) CF 02 41501 03/25/98 I-131 4.37E-03 1.12E-02 4.00E-02 CF 02 41570 04/01/98 I-131 -1.06E-02 1.02E-02 4.02E-02 CF 02 41610 04/08/98 I-131 -1.60E-03 1.20E-02 4.43E-02 CF 02 41812 04/15/98 I-131 5.52E-03 1.11E-02 3.95E-02 CF 02 41954 04/22/98 I-133 9.88E-03 9.31E-03 3.21E-02 CF 02 41981 04/29/98 I-131 -2.63E-05 1.08E-02 3.99E-02 CF 02 42120 05/06/98 I-131 -4.23E-03 8.81E-03 3.39E-02 CF 02 42212 05/13/98 I-131 3.25E-03 8.27E-03 3.06E-02 CF 02 42329 05/20/98 I-131 1.58E-03 9.36E-03 3.46E-02 CF 02 42422 05/27/98 I-131 3.82E-03 9.15E-03 3.27E-02 CF 02 42532 06/03/98 I-131 6.93E-04 1.01E-02 3.71E-02 CF 02 42610 06/10/98 I-131 -1.36E-02 1.09E-02 4.65E-02 CF 02 42709 06/17/98 I-131 7.50E-03 8.79E-03 3.12E-02 CF. 02 42781- 06/24/98 I-131 3.69E-03 1.02E-02 3.76E-02 CF. 02 42899 07/01/98 I-131 -6.71E-03 1.03E-02 3.89E-02 l CF 02 42989 07/08/98 I-131 -1.52E-03 9.46E-03 3.52E-02 CF 02 43067 07/15/98 I-131 7.22E-03 1.03E-02 3.61E-02 , CF 02 43158 07/22/98 I-131 -2.81E-03 9.32E-03 3.52E-02 CF. 02 43301 07/29/98 1-131 1.08E-02 1.05E-02 3.68E-02 CF 02 43374 08/05/98 I-131 1.02E-02 1.09E-02 3.86E-02 CF 02 43506 08/12/98 I-131 0.00E+00 9.60E-03 3.58E-02 CF 02 43640 08/19/98 I-131 1.98E-03 8.62E-03 3.30E-02 CF 02 43867 08/26/98 I-131 1.31E-02 7.68E-03 2.46E-02 CF 02 44062 09/03/98 I-131 -3.29E-03 1.01E-02 3.68E-02 CF 02 44158 09/09/98 I-131 7.34E-03 1.13E-02 4.02E-02 CF 02 44261 09/16/98 I-131 1.19E-03 9.76E-03 3.62E-02 CF 02 44347 09/23/98 I-131 1.33E-03 8.71E-03 3.19E-02 CF 02 44652 09/30/98 I-131 1.88E-02 1.20E-02 3.94E-02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l Seabrook Nuclear Power Station i Radiological Environmental Monitoring System ' ! Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC i (_ ~ TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) I l CF 02 45068 10/07/98 I-131 -2.86E-02 1.13E-02 4.88E-02 l CF 02 45092 10/14/98 I-131 -4.93E-03 8.79E-03 3.43E-02 I CF 02 45272 10/21/98 I-131 7.73E-03 9.47E-03 3.37E-02 I i CF 02 .45406 10/28/98 1-131 6.83E-03 9.11E-03 3.24E-02 CF 02 '45500 11/04/98 I-131 8.98E-03 7.33E-03 2.49E-02 4' CF 02 45682 11/10/98 I-131 -4.32E-03 1.31E-02 4.78E-02 CF 02 45712 11/18/98 I-131 1.35E-03 7.96E-03 2.95E-02 CF 02 45862 11/25/98 I-131 -6.00E-03 7.60E-03 2.98E-02 , I CF 02 46104 12/02/98 I-131 -3.02E-03 1.55E-02 5.56E-02 i i CF 02 46173 .12/09/98 I-131 -1.52E-02 1.38E-02 5.55E-02 I CF 02 46120 12/16/98 I-131 -1.04E-02 9.76E-03 3.83E-02 CF .02 46518 12/23/98 I-131 3.99E-03 1.06E-02 3.75E-02 l CF 02 46583 12/29/98 I-131 5.80E-03 1.03E-02 3.63E-02 l l l i o 1 i l l l l i l l
*- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l'
i i Seabrook Nuclear Power Station ) Radiological Environmental Monitoring System l Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN. END DATE NUCLIDE (pCi/cu.m) (pCi/ cu .m) (pCi/cu.m) CF. 03 4028G 01/07/98 I-131 -5.10E-03 1.08E-02 4.00E-02 CF 03 '40361 01/14/98 I-131 1.69E-02 8.58E-03 2.67E-02 CF 03' 40526 '01/21/98 I-131 9.40E-03 9.20E-03 3.16E-02 CF 03 40615 01/28/98 I-131 0.00E+00 9.52E-03 3.59E-02 CF 03 40686 02/04/98' I-131 -5.18E-03 1.21E-02 4.87E-02 CF 03 40852 02/11/98 I-131 -1.64E-02 9.80E-03 4.18E-02 l CF 03 40920 02/18/98 I-131 -2.73E-02 1.28E-02 6.20E-02 l CF 03 41032 02/25/98 I-131 -5.68E-03 1.24E-02 4.74E-02 CF 03 41209 03/04/98 I-131 1.70E-02 9.69E-03 3.14E-02 CF 03 41291 03/11/98 I-131 -8.05E-03 8.71E-03 3.54E-02 CF 03 41404 03/18/98 I-131 3.41E-03 1.02E-02 3.74E-02 CF 03 41502 03/25/98 I-131 -7.55E-03 9.18E-03 3.63E-02 CF 03 41571 04/01/98 I-131 -1.59E-02 1.03E-02 4.14E-02 CF 03 41611 04/08/98 I-131 -5.90E-03 9.57E-03 3.69E-02 CF 03 41813 04/15/98 I-131 -7.84E-03 1.08E-02 4.15E-02 CF 03 41955 04/22/98 I-131 -4.68E-04 1.05E-02 3.87E CF 03 41982 04/29/98 .I-131 -9.77E-03 9.21E-03 3.74E-02 l 1 CF 03 42121 05/06/98 I-131 3.94E-03 8.81E-03 3.16E-02 I CF 03 42213 05/13/98 I-131 -6.70E-03 9.47E-03 3.76E-02 CF 03 42330 05/20/98 I-131 5.22E-03 9.99E-03 3.61E-02 CF 03 42423 05/27/98 I-131 -1.61E-02 1.03E-02 4.13E-02 CF 03 42533 06/03/98 I-131 -1.22E-04 1.00E-02 3.80E-02 CF 03 42611 06/10/98 I-131 8.28E-03 1.06E-02 3.76E-02 CF 03 42710 06/17/98 I-131 1.19E-02 9.30E-03 3.15E-02 CF 03 42782 06/24/98. I-131 8.01E-03 1.05E-02 3.76E-02 CF 03 42900 07/01/98 I-131 -1.00E-02 1.02E-02 3.97E-02 CF 03 42990 07/08/98 I-131 7.62E-03 1.05E-02 3.66E-02 CF 03 43068 07/15/98 I-131 -3.36E-03 1.19E-02 4.44E-02 CF 03 43159 07/22/98 I-131 -1.08E-02 1.14E-02 4.40E-02 CF 03 43302 07/29/98 I-131 4.14E-03 1.26E-02 4.62E-02 CF 03 43375 08/05/98 I-131 2.86E-03 9.47E-03 3.74E-02 CF 03 43507 08/12/98 I-131 6.43E-03 1.04E-02 3.70E-02 CF 03 43641 08/19/98 I-131 2.21E-02 1.04E-02 3.21E-02 CF 03 43868 08/26/98 I-131 -5.80E-03 9.67E-03 3.89E-02 CF 03 44063 09/02/98 I-131 -3.84E-03 1.21E-02 4.39E-02 CF 03 44159 09/09/98 I-131 1.89E-03 1.12E-02 4.14E-02 CF 03 44262 09/16/98 I-131 -6.82E-03 1.09E-02 4.13E-02 CF 03 44348 09/23/98 I-131 -1.14E-02 9.41E-03 3.75E-02 CF 03 44653 09/30/98 I-131 -7.54E-03 1.22E-02 4.72E-02 i
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
E
D l I i 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data j SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) _(pCi/cu.m) .
--------------------------------------------------- .....---------------------- 1 l
CF 03 45069 10/07/98 I-131 -1.16E-02 1.19E-02 4.74E-02
~'CF 03 45093 10/14/98 I-131 -8.33E-03 8.33E-03 3.34E-02 l CF 03 45273 10/21/98 I-131 8.41E-03 1.07E-02 3.81E-02 I l CF 03 45407 10/28/98 I-131 -9.54E-03 9.71E-03 3.89E-02 l 1
CF 03 45501 11/04/98 I-131 -6.47E-03 9.97E-03 3.89E-02 l CF 03 45683 11/10/98 I-131 2,50E-02 1.33E-02 4.27E-02 CF 03 45713 11/18/98 I-131 -1.79E-02 9.42E-03 3.82E-02' CF 03 45863 11/25/98 I-131 1.30E-03 1.10E-02 3.94E-02 -i CF 03 46105 12/02/98 I-131 4.33E-03 1.49E-02 5.24E-02 CF 03 46174 12/09/98 I-131 -9.96E-03 1.61E-02 6.23E-02 CF 03 46121 12/1C/98 I-131 -3.64E-03 8.91E-03 3.54E-02 l CF 03 46519 12/23/98 I-131 -2.01E-02 1.13E-02 4.50E-02
- l. CF 03 46584 12/30/98 I-131 5.67E-03 9.51E-03 3.37E-02 l 1 l
l l I 1 l 1 l
*' Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
, Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) j CF 04 40287 01/07/98 I-131 -1.25E-02 8.08E-Oo 3.24E-02 8.68E-03 ~
CF 04 40362 01/14/98 I-131 5.01E-03 3.14E-02 CF 04 40517 01/21/98 I-131 -2,44E-09 1.01E-02 3.66E-02 CF 04 40616 01/28/98 I-131 1.52E-02 8.33E-03 2.65E-02 CF 04 40687 02/04/98 I-131 -5.79E-03 1.09E-02 4.39E-02 CF 04 40853 02/11/98 I-131 -4.86E-03 9.86E-03 3.81E-02 CF 04 40921 02/18/98 I-131 1.84E-02 1.04E-02 3.19E-02 CF 04 41033 02/25/98 I-131 2.09E-02 1.10E-02 3.50E-02 CF 04 41210 03/04/98 I-131 6.01E-03 9.38E-03 3.28E-02 CF 04 41292 03/11/98 I-131 -1.60E-02 9.60E-03 3.94E-02 CF 04 41405 03/18/98 I-131 5.53E-03 1.01E-02 3.65E-02 CF 04 41503 03/25/98 I-131 5.19E-03 8.31E-03 2.95E-02 CF 04 41572 04/01/98 I-131 -3.33E-04 9.08E-03 3.38E-02 CF 04 41612 04/08/98 I-131 1.40E-03 1.11E-02 4.01E-02 : CF 04 41814 04/15/98 I-131 -1.49E-03 1.04E-02 3.85E-02 CF 04 41956 04/22/98 I-131 1.51E-03 9.72E-03 3.56E-02 CF 04 41983 04/29/98 I-131 9.41E-03 1.09E-02 3.77E-02 CF 04 42122 05/06/98 I-131 -1.26E-03 9.02E-03 3.34E-02 CF 04 42214 05/13/98 I-131 1.06E-02 7.89E-03 2.65E-02 CF 04 42331 05/20/98 I-131 -3.00E-03 1.04E-02 3.90E-02 CF 04 42424 05/27/98 I-131 -8.31E-03 1.02E-02 3.90E-02 CF 04 42534 06/03/98 I-131 -1.49E-03 8.64E-03 3.28E-02 CF 04 42612 06/10/98 I-131 2.22E-02 9.40E-03 2.66E-02 CF 04 42711 06/17/98 I-131 -1.77E-03 8.49E-03 3.33E-02 CF 04 42783 06/24/98 I-131 1.03E-02 9.94E-03 3.44E-02 CF 04 42901 07/01/98 I-131 -1.51E-02 8.47E-03 3.52E-02 CF 04 42991 C7/08/98 I-131 1.04E-02 9.69E-03 3.30E-02 CF 04 43069 07/15/98 I-131 -1.42E-03 9.72E-03 3.62E-02 CF 04 43160 07/22/98 I-131 1.99E-03 1.01E-02 3.69E-02 CF 04 43303 07/29/98 I-131 -2.45E-02 9.44E-03 4.34E-02 CF 04 43376 08/05/98 I-131 -2.43E-03 1.06E-02 4.24E-02 CF 04 43508 08/12/98 I-131 1.26E-02 1.16E-02 3.94E-02 CF 04 43642 08/19/98 I-131 1.07E-02 9.36E-03 3.19E-02 CF 04 43869 08/26/98 I-131 -1,31E-02 1.03E-02 4.17E-02 CF 04 44064 09/02/98 I-131 -4.28E-03 1.00E-02 3.69E-02 CF 04 44160 09/09/98 I-131 -7.62E-03 9.28E-03 3.73E-02 CF 04 44263 09/16/98 I-131 6.54E-03 8.96E-03 3.19E-02 CF 04 44349 09/23/98 I-131 5.50E-03 8.91E-03 3.16E-02 CF 04 44654 09/30/98 I-131 -8.38E-03 1.22E-02 4.82E-02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
m I Seabrook Nuclear Power Station l-Radiological Environmental Monitoring System Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE ~(pCi/cu.m) (pCi/cu.m) (pCi/cu.m) I l CF 04 45070 10/07/98 I-131 -9.09E-03 1.27E-02 4.89E-02 CF' 04 45094. 10/14/98 I-131 -5.27E-04 1.02E-02 3.75E-02 l CF 04 45274 10/21/98 I-131 8.31E-03 9.99E-03 3.47E-02 l CF 04 45408 10/28/98 I-131 1.32E-02 8.91E-03 2.95E-02 CF 04 45502 11/04/98 I-131 -1.01E-04 1.08E-02 3.96E-02 CF 04 45684 11/10/98 I-131 1.72E-02 1.23E-02 4.10E-02 CF 04 45714 11/18/98 I-131 -7.08E-03 6.02E-03 2.52E-02 CF 04 45864 11/25/98 I-131 5.87E-03 9.89E-03 3.46E-02 CF 04 46106 12/02/98 I-131 2.54E-02 1.62E-02 5.33E-02 CF 04 46175 12/09/98 I-131 2.06E-02 1.75E-02 5.93E-02 CF 04 46122 12/16/98 I-131 -1.02E-02 7.87E-03 3.28E-02 CF 04 46520 12/23/98 I-131 1.36E-02 9.99E-03 3.34E-02 CF 04 46585 12/30/98' I-131 6.98E-03 9.15E-03 3.21E-02 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data -SAMPLE CONC. STD DEV. MDC TYPE STA. LSN DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) _______________________'END CF 05- 40288 '01/07/98 I-131 2.02E-03 8.68E-03 3.11E-02 CF 05 40363 01/14/98 I-131 -1.13E-02 8.69E-03 3.62E-02 CF. .05- 40528 01/21/98 I-131- -4.85E-03 7.07E-03 2.79E-02 CF 05 40617 01/28/98 I-131 -1.02E-02 7.01E-03 3.03E-02 CF- 05 40688 02/04/98 I-131 5.18E-03 1.03E-02 3.91E-02 CF 05 40854 ~02/11/98- I-131 9.62E-03 9.38E-03 3.23E-02 CF 05 40922 '02/18/98 I-131 5.94E-03 1.19E-02 4.46E-02 CF 05 41034 02/25/98 I-131 -1.32E-02 1.22E-02 4.75E-02 CF 05 41211 -03/04/98 I-131 -1.30E-03 7.90E-03 2.98E-02 CF 05 41406 03/18/98 I-131 1.11E-02 7.17E-03 2 29E-02 CF 05 41504 03/25/98 I-131 1.33E-03 8.75E-03 3.19E-02 CF 05 41573 04/01/98 I-131 1.13E-02 9.33E-03 3.16E-02 CF 05 41613 04/08/98 I-131 1.20E-02 9.39E-03 3.16E-02 CF 05 41815 04/15/98 I-131 8.25E-03 9.52E-03 3.30E-02 CF 05 41957 04/22/98 I-131' 5.63E-03 9.94E-03 3.52E-02 CF 05 41984 04/29/98 I-131 -4.25E-03 1.01E-02 3.80E-02 CF 05 42123' 05/06/98 I-131' -1.31E-02 8.01E-03 3.26E-02 CF 05 42215 05/13/98 I-131 1.26E-02 7.38E-03 2.37E-02 CF 05 42332 05/20/98 I-131 5.78E-03 9.66E-03 3.43E-02 CF 05 42425 05/27/98 I-131 2.59E-03 8.60E-03 3.12E-02 CF 05 42535 06/03/98 I-131- 5.28E-03 7.22E-03 2.57E-02 l CF- 05 42613 06/10/98 I-131 1.68E-03 7.31E-03 2.80E-02 CF 05 42712 06/17/98 I-131 3.27E-03 7.68E-03 2.85E-02 CF- 05 42784 06/24/98 I-131 -2.76E-03 8.27E-03 3.17E-02 CF .05 42902 07/01/98 I-131 1.30E-03. 9.31E-03 3.38E-02 CF- 05 42992 07/08/98 I-131 1.46E-02 9.24E-03 3.04E-02 CF 05 43070 07/15/98 .I-131 0.00E+00 9.01E-03 3.32E-02
.CF 05 43161 07/22/98 I-131 4.34E-03 9.49E-03 3.40E-02 CF- 05 43304 07/29/98 I-131' -9.09E-03 1.12E-02 4.51E-02 - CF - 05 -43377 08/05/98 I-131 6.86E-03 1.05E-02 3.81E-02 CF 05 43509 08/12/98 I-131 0.00E+00 8.90E-03 3.32E-02 CF 05 43643 '08/19/98 I-131 -5.81E-03 8.43E-03 3.22E-02 CF 05 43870 08/26/98 I-131 4.35E-03 7.25E-03 2.63E-02 CF 05 44065 09/02/98- I-131 1.05E-03 1.00E-02 3.58E-02 CF 05 44161 09/09/98 I-131 -2.73E-03 9.67E-03 3.61E-02 CF 05 44264 09/16/98 I-131 1.34E-02 9.03E-03 2.99E-02 CF 05 44350 09/23/98 I-131. 1.60E-02 9.23E-03 2.99E-02 CF. 05 44655 09/30/98 I-131 1.90E-03 1.09E-02 4.05E-02 * ; Radioactivity detected in sample (i.e., CONC > 3'STD. DEV.) !
i j
7. l Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data l l SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CF 05 45071 10/07/98 I-131 6.38E-03 9.57E-03 3.40E-02 CF 05 45095 10/14/98 I-131 5.35E-03 8.03E-03 2.85E-02 CF 05 45275 10/21/98 I-131. 4.81E-03 7.00E-03 2.51E-02 4 CF 05 '45409 10/28/98 I-131 -6.06E-03 8.83E-03 3.48E-02 CF 05 45503 11/04/98 I-131 1.24E-02 8.57E-03 2.84E-02 CF 05 45685 11/10/98 I-131 -9.35E-03 1.17E-02 4.39E-02 CF 05- 45715 11/18/98 I-131 0.00E+00 6.58E-03 2.49E-02 CF 05 45865 11/25/98 I-131 -1.25E-02 9.02E-03 3.52E-02 CF 05 46107 12/02/98 I-131 1.55E-02 1.35E-02 4.53E-02 CF 05 46176 12/09/98 I-131 -2.10E 1.31E-02 4.93E-02 CF 05 46123 12/16/98 I-131 7.91E-03 8.12E-03 2.81E-02 CF 05 46521- 12/23/98 I-131 3.73E-03 9.04E-03 3.22E-02 CF- 05 46586 12/29/98, I-131 1.19E-02 1.17E-02 4.00E-02 I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CF' 06 45072 10/07/98 I-131 9.04E-03 1.21E-02 4.2SE-02 CF 06 45096 10/14/98 I-131 -2.96E-03 9.59E-03 3.63E-02 CF. 06 45276' 10/21/98 I-131 -1.31E-03 8.39E-03 3.15E-02 CF 06 45410 10/28/98 I-131 -2.90E-03 8.46E-03 3.26E-02 CF 06- '45504 11/04/98 I-131 4.54E-03 9.44E-03 3.39E-02 CF 06 45686 11/10/98 I-131 -8.98E-03 1.20E-02 4.52E-02 CF 06 '45716 11/18/98 I-131 2.69E-03 9.51E-03 3.43E-02 CF 06 45866 11/25/98 I-131 1.28E-02 9.03E-03 3.00E-02 CF 06- 46108 12/02/98 I-131 -2.22E-02 1.49E-02 5.70E-02 CF 06 46177 12/09/98 I-131 0.00E+00 1.45E-02 5.38E-02 CF 06 46124 12/16/98 I-131 2.19E-02 9.67E-03 2.97E-02 CF 06 46522 12/23/98 I-131 -7.94E-03 1.06E-02 4.00E-02 CF 06 46587 12/29/98 I-131 0.00E+00 1.14E-02 4.17E-02 Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
g Seabrook Nuclear Power Station Radiological Environmental Monitoring System i Summary of 1998 Data j SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE - NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CF 06 40289 01/06/98 I-131 -1.37E-02 1.01E-02 3.93E-02 CF- 06 40364 01/14/98 I-131 4.61E-03 1.08E-02 4.01E-02 CF 06 40529 01/21/98 I-131 6.35E-03 8.89E-03 3.12E-02 ] i CF 06 40618 01/28/98 I-131 1.13E-02 8.07E-03 2.69E-02 ] CF 06 40689 02/04/98 I-131 -1.44E-02 1.13E-02 4.83E-02 CF 06 40855 02/11/98 I-131 -1.74E-03 1.03E-02 3.90E-02 CF 06 40923 02/18/98 I-131 1.10E-02 8.95E-03 3.07E-02 CF 06 41035 02/25/98 I-131 1.07E-02 1.13E-02 3.92E-02 CF 06 41212 03/04/98 I-131 2.46E-03 8.17E-03 2.96E-02 CF 06 41294 03/11/98 I-131 -1.07E-02 1.11E-02 4.31E-02 CF 06 41407 03/18/98 'I-131 -5.00E-03 1.06E-02 4.36E-02 CF 06 41505 03/25/98 I-131 -1.50E-03 8.74E-03 3.28E-02 CF 06 41574 04/01/98 I-131 2.46E-03 9.41E-03 3.41E-02 CF 06 41614 04/08/98 I-131 -2.91E-02 1.12E-02 4.75E-02 CF 06 41816 04/15/98 I-131 -4.00E-03 1.04E-02 3.96E-02 CF 06 41958 04/22/98 I-131 -3.04E-02 1.04E-02 4.55E-02 CF 06 41985 04/29/98 I-131 1.61E-03 1.13E-02 4.11E-02 CF 06 42124 05/06/98 I-131 2.47E-03 8.36E-03 3.02E-02 l CF 06 42216 05/13/98 I-131 -1.24E-02 8.77E-03 3.65E-02 CF 06 42333 05/20/98 I-131 -1.16E-02 1.08E-02 4.29E-02 l CF 06 42426 05/27/98 I-131 -1.11E-02 1.06E-02 4.03E-02 l CF 06 42536 06/03/98 I-131 -7.42E-03 9.96E-03 3.86E-02 CF 06 42614 06/10/98 I-131 1.43E-02 8.70E-03 2.81E-02 CF 06 42713 06/17/98 I-131 5.61E-03 8.97E-03 3.26E-02 CF 06 42785 06/24/98 I-131 -7.42E-03 8.78E-03 3.49E-02 l CF 06 42903 07/01/98 I-131 -1.90E-02 1.44E-02 5.56E-02 l CF 06 42993 07/08/98 I-131 9.12E-03 9.66E-03 3.32E-02 l CF 06 43071 07/15/98 I-131 0.00E+00 9.71E-03 3.57E-02 l CF 06 43162 07/22/98 I-131 -1.37E-03 8.95E-03 3.35E-02 l CF 06 43305 07/29/98 I-131 1.83E-03 1.08E-02 4.01E-02 CF 06 43378 08/05/98 I-131 1.51E-02 1.12E-02 3.77E-02 CF 06 43510 08/12/98 I-131 -6.84E-03 8.76E-03 3.42E-02 CF 06 43644 08/19/98 I-131 6.60E-03 8.65E-03 3.03E-02 CF 06 43871 08/26/98 I-131 0.00E+00 8.06E-03 3.08E-02 CF 06 44066 09/02/98 I-131 3.59E-03 1.06E-02 3.75E-02 CF 06 44162 09/09/98 I-131 -1.82E-02 1.03E-02 4.22E-02 CF 06 44265 09/16/98 I-131 2.18E-02 9.93E-03 3.06E-02 CF 06 44351 09/23/98 I-131 1.34E-03 9.58E-03 3.48E-02 , 44656 09/30/98 4.71E-02
,CF 06 I-131 -1.88E-03 1.26E-02 ~* Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) CF 07 40290 01/07/98 I-131 -1.07E-02 8.62E-03 3.39E-02 CF- 07 40365 01/14/98 I-131 -1.22E-02 1.00E-02 4.42E-02 CF 07 40530 01/21/98 I-131 -1.27E-03 9.26E-03 3.42E-02 CF 07 40619 01/28/98 I-131 7.78E-03 9.21E-03 3.23E-02 CF 07 -40690 02/04/98 I-131 7.13E-03 1.04E-02 3.77E-02 CF 07 40856 02/11/98 I-131 1.76E-02 1.22E-02 4.04E-02 CF 07 40924 02/18/08 I-131 -3.09E-03 1.28E-02 5.15E-02 CF 07 41036 02/25/98 I-131 5.80E-04 8.82E-03 3.35E-02 CF 07 41213 03/04/S6 I-131 -6.10E-03 9.05E-03 3.44E-02 CF 07 41295 03/11/98 I-131 -4.49L-03 9.59E-03 3.67E-02 CF 07 41408 03/18/98 I-131 0.00E+00 9.91E-03 3.93E-02 CF 07 41506 03/25/98 I-131 9.92E-03 8.65E-03 2.93E-02 CF 07 41575 04/01/98 I-131 -2.76E-03 1.03E-02 3.83E-02 CF 07 41615 04/08/98 I-131 -1.90E-02 1.05E-02 4.32E-02 CF 07 41817 04/15/98 I-131 9.56E-03 1.08E-02 3.75E-02 CF 07 41959 04/22/98 I-131 -9.62E-03 1.09E-02 4.24E-02 CF 07 41986 04/29/98 I-131 2.09E-03 1.08E-02 3.95E-02 CF 07= 42125 05/06/98 I-131 1.6PE-02 9.08E-03 2.92E-02 CF 07 42217 05/13/98 I-131 1.20E-02 7.42E-03 2.40E-02
.CF 07 42334 05/20/98 I-131 1.60E-03 9.19E-03 3.41E-02 CF 07 42427 05/27/98 I-131 -8.83E-03 1.03E-02 3.91E-02 CF 07 42537 06/03/98 I-131 -1.01E-02 9.00E-03 3.60E-02 CF 07 42615 06/10/98 I-131 -9.22E-03 8.04E-03 3.47E-02 CF 07 42714 06/17/98 I-131 8.25E-03 8.94E-03 3.11E-02 CF 07 42786 06/24/98 I-131 -1.30E-02 9.26E-03 3.76E-02 CF 07 42904 07/01/98 I-131 -5.70E-03 1.00E-02 3.70E-02 CF 07 42994 07/08/98 I-131 -1.30E-03 8.53E-03 3.19E-02 CF 07 43072 07/15/98 I-131 -5.54E-03 9.19E-03 3.53E-02 CF 07 43163 07/22/98 I-131 1.62E-02 9.54E-03 3.10E-02 CF 07 43306 07/29/98 I-131 -1.24E-02 9.21E-03 3.88E-02 CF 07 43379 08/05/98 I-131 5.84E-03 1.22E-02 4.48E-02 CF 07 43511 08/12/98 I-131 2.72E-03 9.62E-03 3.47E-02 CF 07 43645 08/19/98 I-131 -1.96E-02 8.56E-03 3.62E-02 CF 07 43872 08/26/98 I-131 1.49E-02 9.83E-03 3.24E-02 CF 07 '44067 09/02/98 I-131 3.49E-03 9.24E-03 3.28E-02 CF 07 44163 09/09/98 I-131 0.00E+00 1.09E-02 4.00E-02 CF 07 44266 09/16/98 I-131 -3.42E-03 1.04E-02 3.94E-02 CF 07 44352 09/23/98 I-131 -8.94E-03 9.12E-03 3.55E-02 CF 07 44657 09/30/98 I-131 -1.70E-02 1.08E-02 4.54E-02 Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.) )
l
Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE .NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) l ------------------------------------------------------------------------- ..--- CF 07 45073 10/07/98 I-131 -7.07E-03 1.03E-02 4.06E-02 CF 07 45097 10/14/98 I-131 0.00E+00 8.97E-03 3.27E-02 CF 07. .5277 10/21/98 I-131 1.06E-02 7.50E-03 2.50E-02 CF 07 45411 10/28/98 I-131 -1.84E-02 8.39E-03 3.62E-02 l CF 07 45505 11/04/98 I-131 1.20E-02 1.02E-02 3 '. 4 4 E-02 CF 07 45687 11/10/98 I-131 1.18E-02 1.27E-02 4.35E-02 ! CF 07 45717 11/18/98 I-131 -8.39E-03 9.06E-03 3.55E-02 l CF 07 45867 11/25/98 I-131 -2.32E-03 9.14E-03 3.37E-02 CF 07 46109 12/02/98 I-131 1.55E-03 1.48E-02 5.26E-02 l CF 07 46178 12/09/98 I-131 6.78E-03 1.22E-02 4.41E-02 l- CF 07 46125 12/16/98 I-131 -1.08E-02 9.74E-03 3.88E-02 ! CF 07 46523 12/23/98 I-131 1.33E-03 9.50E-03 3.45E-02 CF 07 46588 12/29/98 I-131 3.06E-03 1.21E-02 4.31E-02 l l l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l' l O 4 Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1990 Data l' -SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/cu.m) (pCi/cu.m) (pCi/cu.m) l, .. ..____.........____________.._____________________________________._________ j
'CF 08 40291 01/07/98. I-131, -7.31E-03 1.01E-02 3.78E-02 CF 08~ 40366. 01/14/98 I-131 2.36E-02 1.18E-02 3.62E-02 'CF- 08 40531 01/21/98 I-131 -5.13E-03 8.28E-03 3.20E-02 CF' 08 40620 01/28/98 .I-131 1.28E-02 8.43E-03 2.78E-02 CF 08 .40691' 02/04/98 I-131 1.42E-02 1.08E-02 3.65E-02 CF 08 40857 02/11/98' I-131- 1.78E-02 9.27E-03 2.91E T CF 08 40925 02/18/98 I-131 '1.82E-02 1.27E-02 4.20E-02 CF 08 '
41037 02/25/98 I-131 4.48E-03 8.65E-03 3.17E-02 CF 08 41214. 03/04/98 I-131 -1.12E-02 9s54E-03 3.71E-02 3 CF 08 41296 03/11/98 I-131 4.57E-03 1.09E-02 3.88E-02 l l CF 08 41409 03/18/98- I-131 2.52E-03 9.74E-03 3.78E-02 L CF 08 41507 03/25/98. I-131 1.25E-03 8.93E-03 3.25E-02 I CF 08 <41576 04/01/98 I-131 2.81E-03 1.01E-02 3.64E-02 l ' CF 08 41616 04/08/98 I-131 1.81E-02 1.13E-02 3.69E-07 j CF 08- 41818 04/15/98 I-131 '2.53E-03 1.02E-02 3.85E-02 1 CF 08 -41960 04/22/98 I-231 1.31E-02 1.08E-02 3.66E-02 CF '08 41987 04/29/98 I-131 -1.13E-02 1.26E-02 5.07E-02 CF. 08 42126 05/06/98 I-131 -1.08E-02 8.79E-03 3.52E-02 CF 08- 42218 05/12/98 I-131 -9.64E-03 9.27E-03 3.74E-02 l CF 08 42335 05/20/98 I-131 -1. 8'4E- 02 9.52E-03 3.98E-02 I CF 08 42428 05/27/98 I-131 5.92E-03 9.84E-03 3.44E-02
'CF 08 42538 06/03/98 I-131 -2.19E-02 9.78E-03 4.11E-02 CF- 08 42616 06/10/98 I-131 7.49E-03 7.95E-03 2.81E-02 i CF 08 42715 06/17/98 I-131 -3.31E-03 7.63E-03 3.00E-02 .CF .08 42787 06/24/98- I-113 -4.53E-03 1.04E-02 3.92E-02
- .
- CF. 08 42905 07/01/98 I-131 9.06E-03 8.87E-03 3.04E-02 l CF 08 42995 07/08/99 I-131 -1. 06 E-0: 9.52E-03 3.72E-02 CF 08 430'!3 07/15/98 I-131 1.13E-02 9.05E-03 13.05E-02 CF 08 43164 07/22/98 I-131 -6.74E-03 8.84E-03 3.44E-02 CF 08 43307 07/29/98 I-131 1.85E-03 9.94E-03 3.71E-02 CF 08 43380 08/0$/98 I-131 -7.40E-03 1.13E-02 4.64E-02 CF 08 43512 08/12/98 I-131 -7.81E-03 8.12E-03 3.27E-02 CF -08 43646 08/19/98 I-131 -2.60E-03 8.44E-03 3.19E-02 CF 08 43873 08/26/98 I-131 1.26E-02 1.06E-02 3.58E-02 CF 08 44164 09/09/98 I-131 -4.68E-03 1.050 02 3.98E-02 CF 08 44267 09/16/98 I-131 0.00E+00 1.16E-02 4.26E-02 CF 08 44353 09/23/98 I-131 5.71E-03 8.66E-03 3.05E-02 ,
CF 08 44658 09/30/98 I-131 -3.05E-02 1.21E-02 5.21E-02 l
* -Radioactivity detected in ssmple (i.e., CONC > 3 STD. DEV.)
o
l 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring System Summary of 1998 Data SAMPLE CONC. STD DEV. MDC l TYPE STA. LSN END DATE NUCLIDE (pC1/cu.m) (pCi/cu.m) (pCi/cu.m) j CF 08 45074 10/07/98 I-131 0.00E+00 1.26E-02 4. 64E- 02 CF 08 45098 10/14/98 I-131 -2.97E-03 9.40E-03 3.57E-02 l CF 08 45278 10/21/98 I-131 -5.31E-03 9.58E-03 3.63E-02 I CF 08 45412 10/28/98 I-131 1.60E-02 8.36E-03 2.64E-02 l l CF 08 45506 11/04/98 I-131 -9.00E-03 9.49E-03 3.75E-02 I CF 08 45688 11/10/93 I-131 -1.83E-02 1.34E-02 5.16E-02 ; CF 08 45718 11/18/98 I-131 1.16E-02 8.62E-03 2.88E-0^ ! CF 08 45868 11/25/98 I-131 2.37E-03 1.07E-02 3.81E-02 l l CF 08 46110 12/02/98 I-131 1.12E-02 1.54E-02 5.32E-02 l CF 08 46179 12/09/98 I-131 2.30E-03 1.44E-02 5.28E-02 l CF 08 46126 12/16/98 I-131 4.42E-03 9.66E-03 3.46E-02 l CF 08 46524 12/23/98 I-?ti 0.00E+00- 1.00E-02 3.66E-02 l CF 08 46589 12/30/98 L 1 -7.23E-03 8.35E-03 3.32E-02 I l l l l l l l l f I l
- Radioactivity detected in sw1ple (i.e., CONC > 3 Si?0. DEV.)
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) Fish FH 03 40972 02/17/98 Ag-110M -1.06E+01 1.04E+01 4.24E+01 FH 03 40972 02/17/98 Ba-140 2.52E+00 1.31E+01 5.07E+01 FH 03 40972 02/37/98 Be-7 -1.96E+02 7.12E+01 2.94E+02 FH 03 40972 02/17/98 Ce-141 -1.62E+01 1.27E+01 4.37E+01 FH 03 40972 02/17/90 Ce-144 -4.34E+01 3.97E+01 1.36E+02 FH 03 40972 02/17/'/8 Co-57 .t . 9 0 E+ 0 0 5.03E+00 1.60E+01 FH 03 40972 02/17/98 Co-58 -1.60E+00 6.13E+00 2.36E+01 FH 03 40972 02/17/98 Co-60 8.67E+00 7.99E+00 2.66E+01 FH 03 40972 02/17/98 Cr-51 -3.98E+01 6.70E+01 2.45E+02 FH 03 40972 02/17/98 Cs-134 3.31E+00 7.92E+00 2.66E+01 FH 03 40972 02/17/98 Cs-137 7.30E+00 8.88E+00 3.11E+01 FH 03 40972 02/17/98 Fe-59 5.47E+00 2.15E+01 7.92E+01 FH 03 40972 02/17/98 I-131 -2.69E+00 1.52E+01 5.44E+01 FH 03 40972 02/17/98 K-40 1.50E+03 2.21E+02 5.00E+02
- FH 03 40972 02/17/98 Mn-54 -0.38E+00 8.24E+00 2.93E+01 FH 03 40972 02/17/98 Ru-103 -5.60E+00 7.49E+00 2.87E+01 FH 03 40972 02/17/98 Ru-106 9.87E+01 7.60E+01 2.56E+02 ,
FH 03 40972 02/17/98 Sb-124 4.07E+01 1.84E+01 4.88E+01 FH 03 40972 02/17/98 Se-75 1.18E+01 1.01E+01 3.25E+01 FH 03 40972 02/17/98 Th-232 -8.51E+00 3.22E+G1 1.22E+02 FH 03 40972 02/17/98 Zn-65 2.29E+01 3.18E+01 1.25E+02 FH 03 40972 02/17/98 Zr-95 -1.79E+01 1.45E+01 5.65E+01 FH 03 42293 05/18/98 Ag-110M 0.76E+00 8.22E+00 2.89E+01 FH 03 42293 05/18/98 Ba-140 -8.93E+00 1.60E+01 6.23E+01 FH 03 42293 05/18/98 Be-7 -1.09E+02 6.16E+01 2.35E+02 FH 03 42293 05/18/98 Ce-141 4.10E+00 .1.07E+01 3.36E+01 FH 03 42293 05/18/98 Ce-144 -6.08E+01 3.16E+01 1.10E+02 FH 03 42293 05/18/98 Co-57 4.71E+00 4.62E+00 1.41E+01 i FH 03 42293 05/18/98 Co-58 -2.62E+00 7.69E+00 2.72E+01 I FH 03 42293 05/18/98 Co-60 0.00E+00 7.88E+00 2.89E+01 , FH 03 42293 05/18/98 Cr-51 -8.24E+01 7.27E+01 2.62E+02 l FH 03 42293 05/18/98 Cs-134 3.10E+00 7.67E+00 2.51E+01 FH 03 42293 05/18/98 Cs-137 0.00E+00 8.58E+00 3.09E+01 FH 03 42293 05/18/98 Fe-59 -1.30E+01 1.93E+01 7.68E+01 FH 03 42293 05/16/98 I-131 3.89E+01 2.31E+01 7.22E+01 FH 03 42293 05/18/98 K-40 3.67E+03 2.53E+02 4.02E+02
- FH 03 42293 05/18/98 Mn-54 1.05E+00 7.27E+00 2.47E+01
- FH 03 42293 05/18/98 Ru-103 0.85E+00 7.56E+00 2.63E+01
}' FH 03 42293 05/18/98 Ru-106 8.52E+01 6.49E+01 2.17E+02 / FH 03 42293 05/18/98 Sb-124 -1.43E+01 1.64E+01 6.77E+01 FH 03 42293 05/18/98 Se-75 9.24E+00 9.35E+00 3.02E+01 FH 03 42293 05/18/98 Th-232 -1.85E+01 2.82E+01 1.02E+02 FH 03 42293 05/18/98 Zn-65 -2.29E+01 4.04E+01 1.53E+02 FH 03 42293 05/18/98 Zr-95 0.00E+00 1.34E+01 4.95E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station
' Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE- CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi,kg) (pCi/kg) (pCi/kg)
FH 03 43547 08/17/98 Ag-110M 1.01E+01 1.19E+01 3.92E+01 FH 03 43547 08/17/98 Ba-140 -1.94E+01 1.19E+01 5.60E+01 FH 03 43547 08/17/98 Be-7 3.14E+01 7.32E+01 2.51E+02 FH 03 43547 08/17/98 Ce-141 -2.23E+01 1.15E+01 3.98E+01 FH 03 43547 08/17/98 Ce-144 1.85E+01 4.27E+01 1. 3 4 E+ 0'. FH 03 43547 08/17/98 Co-57 9.53E+00 5.77E+00 1.71E+01 FH 03 43547 08/17/98 Co-58 2.04E+01 8.24E+00 2.24E+01 FH 03 43547 08/17/98 Co-60 3.87E+00 1.10E+01 3.97E+01 FH 03' 43547 08/17/98 Cr-51 1.97E+01 8.43E+01 2.86E+02 a; 03 43547 08/17/98 Cs-134 -6.33E+00 7.69E+00 2.81E+01 ea 03 43547 08/17/98 Cs-137 3.04E+00 9.07E+00 3.30E+01 FH 03 43547 08/17/98 Fe-59 5.69E+01 2.66E+01 7.76E+01 FH 03 43547 08/17/98 I-131 1.48E+01 1.68E+01 5.55E+01 4 FH 03 43547 08/17/98 K-40 2.96E+03 2.91E+02 5.22E+02 * ) FH 03 43547 08/17/98 Mn-54 3.86E+00 8.65E+00 2.94E+01, 1 FH 03 43547 08/17/98 Ru-103 1.21E+01 8.17E+00 2.59E+01 ! FH 03 43547 08/17/98 Ru-106 -5.99E+01 8.65E+01 3.32E+02 FH 03 43547 08/17/98 Sb-124 7.29E+00 1.91E+01 7.19E+01 FH 03 43547 08/17/98 Se-75 1.98E+00 1.13E+01 3.82E+01 FH (3 43547 08/17/98 Th-232 8.98E+01 3.50E+01 9.64E+01 FH 03 43547 08/17/98 Zn-65 1.16E+01 2.00E+01 6.67E+01 FH 03 43547 08/17/98 Zr-95 2.24E+01 1.36E+01 4.14E+01 FH 03 45785 11/23/98 Ag-110M -1.43E+01 1.70E+01 7.05E+01 FH 03 45785 11/23/98 Ba-140 7.04E+00 1.92E+01 7.81E+01 FH 03 45785 11/23/98 Be-7 -4.64E+01 1.04E+02 4.00E+02 FH 03 45785 11/23/98 Ce-141 -1.18E+01 1.60E+01 5.49E+01 FH 03 45785 11/23/98 Ce-144 -2.77E+01 6.21E+01 2.08E+02 FH 03 45785 31/23/98 Co-57 -1.54E+01 7.24E+00 2.66E+01 FH 03 45785 11/23/98 Co-58 1.73E+00 1.28E+01 4.75E+01 l FH- 03 45785 11/23/98 Co-60 -4.85E+00 1.88E+01 7.70E+01 FH 03 45785 11/23/98 Cr-51 8.77E+01 1.01E+02 3.39E+02 FH 03 45785 11/23/98 Cs-134 -8.10E+00 1.29E+01 4.85E+01 FH 03 45785 11/23/98 Cs-137 6.13E+00 1.37E+01 5.11E+01 FH 03 45785 11/23/98 Fe-59 3.17E+01 3.82E+01 1.38E+02 I
, FH 03 45785 11/23/98 I-131 2.24E+00 2.17E+01 7.94E+01 I FH 03 45785 11/23/98 K-40 3.19E+03 4.52E+02 8.48E+02
- FH 03 45785 11/23/98 Mn-54 0.82E+00 1.22E+01 4.56E+01 FH Ce3 45785 11/23/98 Ru-103 9.96E+00 1. 44E+ 03 4.95E+01 FH 03 45785 11/23/98 Ru-106 3.58E+01 1.17E+02 4.40E+02 FH 03 45785 11/23/98 Sb-124 -1.36E+01 2.96E+01 1.41E+02 FH 03 45785 11/23/98 Se-75 3.88E+00 1.44E+01 4.99E+01 FH 03 45785 1.1/23/98 Th-232 1.25E+02 5.65E+01 1.57E+02 FH 03- 45785 .1/23/98 Zn-65 1.93E+01 3.29E+01 1.13E+02 FH 03 45785 11/23/98 Zr-95 1.67E+01 2.18E+01 7.51E+01
- Radioactivity detected in samplo (i . e . , CONC > 3 STD. DEV. )
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program . Summary of 1998 Data { SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) !
l FH 53 40884 02/17/98 Ag-110M -2.74E+00 1.51E+01 5.42E+01 FH 53 40884 02/17/98 Ba-140 -8.95E+00 1.32E+01 5.37E+01 i FH 53 40884 02/17/98 Be-7 1.59E+01 9.85E+01 3.38E+02 )
FH 53 40884 02/17/98 Ce-141 1.72E+01 1.43E+01 4.30E+01 ( FH 53 40884 02/17/98 Ce-144 4.58E+01 5.51E+01 1.69E+02 l FH 53 40884 02/17/98 Co-57 -2.77E+00 6.76E+00 2.19E+01 i FH 53 40884 02/17/98 Co-58 -1.14E+01 1.37E+01 4.92E+01 j FH 53 40884 02/17/98 Co-60 -2 06E+01 1.44E+01 5.91E+01 j FH 53 40884 02/17/98 Cr-51 3.16E+00 9.69E+01 3.29E+02 < FH 53 40884 02/17/98 Cs-134 -1.11E+01 1.36E+01 4.73E+01 FH 53 40884 02/17/98 Cs-137 -1.83E+00 1.50E+01 5.45E+01 FH 53 40884 02/17/98 Fe-59 -4.57E+01 3.72S+01 1.48E+02 , FH 53 40884 02/17/98 I-131 -1.38E+01 1.47E+01 5.26E+01 1 FH 53 40884 02/17/98 K-40 3.71E+03 4.20E+02 9.91E+02
- FH 53 40884 02/17/98 Mn-54 -1.67E+00 1.36E+01 4.68E+01 FH 53 40884 02/17/98 Ru-103 -5.59E+00 1.15E+01 4.11E+01 FH 53 40884 02/17/98 Ru-106 6.06E+01 1.37E+02 4.82E+02 FH 53 40884 02/17/98 Sb-124 1.14E+01 2.57E+01 9.39E+01 FH 53 40884 02/17/98 Se-75 1.50E+01 1.54E+01 4.98E+01 FH 53 40884 02/17/98 Th-232 3.28E+01 5.33E+01 1.80E+02 FH 53 40884 02/17/98 Zn-65 -5.31E+01 3.32E+01 1.30E+02 FH 53 40884 02/17/98 Zr-95 2.92E+01 2.19E+01 6.87E+01 FH 53 40885 02/17/98 Ag-110M -2,27E+01 1.10E+01 5.08E+01 FH 53 40885 02/17/98 Ba-140 5.84E+00 9.54E+00 3.62E+01 FH 53 40885 02/17/98 Be-7 -8.31E+]O 6.23E+01 2.35E+02 FH 53 40885 02/17/98 Ce-141 6.71E+00 1.16E+01 3.67E+01 -
FH 53 40885 02/17/98 Ce-144 9.97E+01 4.68E+01 1.34E+02 l FH 53 40885 02/17/98 Co-57 -1.15E+00 6.02E+00 1.98E+01 FH 33 40885 02/17/98 Co-58 -5.44E+00 8.67E+00 3.43E+01 , FH 53 40885 02/17/98 Co-60 -0.39E+00 1.06E+01 4.23E+01 FH 53 40885 02/17/98 Cr-51 -4.04E+01 8.78E+01 3.13E+02 l FH 53 40885 02/17/98 Cs-134 -1.49E+01 1.00E+01 3.88E+01 FH 53 40885 02/17/98 Cs-137 -1.05E+01 1.13E+01 4.59E+01 FH 53 40885 02/17/98 Fe-59 -6.26E+00 2.94E+01 1.16E+02 FH 53 40885 02/17/98 I-131 4.15E+00 1.15E+01 3.99E+01 FH 53 40585 02/17/98 K-40 2.18E+03 3.03E+02 5.90E+02
- FH 53 40885 02/17/98 Mn-54 -7.04E+00 8.78E+00 3.51E+01 FH 53 40885 02/17/98 Ru-103 8.96E+00 1.01E+01 3.37E+01 FH 53 40885 02/17/98 Ru-106 -1.74E+01 1.09E+02 4.09E+02 FH 53 40885 02/17/98 Sb-124 -1.45E+01 2.10E+01 9.50E+01 FH 53 40885 02/17/98 Se-75 1.16E+01 1.24E+01 4.07E+01 FH 53 40885 02/17/98 Th-232 4.16E+01 4.21E+01 1.42E+02 FH 53 40885 02/17/98 Zn-65 -4.86E+01 2.36E+01 1.06E+02 FH 53 40885 02/17/98 Zr-95 -1.02E+01 1.64E+01 6.35E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seab.aok Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) FH 53 42294 05/18/98 Ag-110M 1.24E+01 1.35E+01 4.48E+01 FH 53 42294 05/18/98 Ba-140 -2.84E+01 2.38E+01 1.10E+02 FH 53 42294 05/18/98 Be-7 9.45E+01 7.91E+01 2.58E+02 q FH 53 42294 05/18/98 Ce-141 3.73E+01 1.45E+01 4.05E+01 q FH 53 42294 05/18/98 Ce-144 -5.21E+01 4.05E+01 1.40E+02 FH 53 42294 05/18/98 Co-57 2.52E+00 5.37E+00 1.70E+01 FH 53 42294 05/18/98 Co-58 1.69E+00 1.02E+01 3.64E+01 , FH 53 42294 05/18/98 Co-60 0.24E+00 1.20E+01 4.61E+01 ]' FH 53 42294 05/18/98 Cr-51 -1.43E+02 1.06E+02 3.94E+02 FH 53 42294 05/18/98 Cs-134 -3.00E+00 9.32E+00 3.1GE+01 FH 53 42294 05/18/98 Cs-137 -3.67E+00 9.71E+00 3.80E+01 J FH 53 42294 05/18/98 Fe-59 1.31E+01 2.47E+01 9.44E+01 FH 53 42294 05/18/98 I-131 -1.09E+01 3.19E+01 1.18E+02 FH 53 42294 05/18/98- K-40 3.53E+03 3.74E+02 7.12E+02
- FH 53 42294 05/18/98 Mn-54 7.00E+00 9.35E+00 3.15E+01 1 FH 53 42294 05/18/98 Ru-103 -1.03E+01 1.12E+01 4.28E+01 l FH 53 42294 05/18/98 Ru-106 -4.67E+01 8.95E+01 3.50E+02 FH 53 42294 05/18/98 Sb-124 1.34E+01 2.54E+01 9.54E+01 FH 53 42294 05/18/98 Se-75 -1.74E+00 1.08E+01 3.79E+01 FH 53 42294 05/18/98 Th-232 4.49E+01 3.86E+01 1.28E+02 FH 53 42294 05/18/98 Zn-65 1.66E+01 2.29E+01 8.05E+01 FH 53 42294 05/18/98 Zr-95 1.16E+01 2.15E+01 7.78E+01 FH 53 43548 08/17/98 Ag-110M 4.33E+00 8.28E+00 2.82E+01 <
FH 53 43548 08/17/98 Ba-140 1.16E+00 7.58E+00 3.06E+01 l FH 53 43548 08/17/98 Be-7 -4.64E+00 4.35E+01 1.56E+02 ) FH 53 43548 08/17/98 Ce-141 -7.80E+00 6.96E+00 2.33E+01 l FH 53 43548 08/1'i/98 Co-144 9.43E+00 2.73E+01 3.552+01 FH 53 43548 08/17/98 Co-57 0.29E+00 3.12E+00 9.93E+00 FH 53 43548 08/17/98 Co-58 2.27E+00 6.04E+00 2.08E+01 FH 53 43548 08/17/98 Co-60 3.23E+00 6.46E+00 2.42E+01 FH 53 43548 08/17/98 Cr-51 -7.18E+01 4.77E+01 1.79E+02 FH 53 43548 08/17/98 Cs-134 5.72E+00 6.09E+00 1.79E+01 FH 53 43548 08/17/98 Cs-137 3.02E+00 6.61E+00 2.37E+01 FH 53 43548 08/17/98 Fe-59 -4.72E+00 2.04E+01 7.76E+01 FH 53 43548 08/17/98 I-131 -1.53E+01 1.21E+01 4.45E+01 FH 53 43548 08/17/98 K-40 3.60E+03 2.69E+02 4.27E+02
- FH 53 43548 08/17/98 Mn-54 -1.46E+01 6.02E+00 2.49E+01 FH 53 43548 08/17/98 Ru-103 7.35E+00 6.11E+00 1.98E+01 FH 53 43548 08/17/98 Ru-106 1.68E+01 6.07E+01 2.19E+02 FH 53 43548 08/17/98 Sb-124 2.18E+01 1.95E+01 6.61E+01 FH 53 43548 08/17/98 Se-75 1.81E+00 6.81E+00 2.29E+01 FH 53 43548 08/17/98 Th-232 5.46E+01 2.27E+01 6.31E+01 FH 53 43548 08/17/98 Zn-65 -7.29E+00 1.79E+01 6.62E+01 FH $3 43548 08/17/98 Zr-95 -1.55E+01 ' 1.13 F.+ 01 4.35E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD DEV.)
Seabrook Nuclear Power Station
-Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN- END DATE NUCLIDE (pCi/kg) (pCi/kg) .(pCi/kg)
FH 53- 45736 11/16/98 Ag-110M 4.69E+00 1.92E+01 6.94E+01 FH . 53 '45736 11/16/98 Ba-140 5.58E+01 4.11E+01 1.31E+02 FH 53- 45736 11/16/98 Be-7 -8.76E+01 1.24E+02 4.79E+02 FH 53 45736 11/16/98 Ce-141 -5.17E+00 2.03E+01 6.75E+01 -FH 53 45736 11/16/98 Ce-144 -5.43E+01 4.58E+01 1.67E+02 FH 53 45736 11/16/98 Co-57 1.1 '?,+ 01 6.63E+00 1.95E+01 FH 53 45736 11/16/98 Co-58 2.78E+00 1.45E+01 5.30E+01 FH 53- 45736 11/16/98 Co-60 4.63E+00 1.04E+01 4.30E+01 FH 53 45736 11/16/98 Cr-51 ;1.14E+02 1.42E+02 4.78E+02 ; FH 53 .45736 11/16/98 Cs-134 -1.68E+01 1.19E+01 4.75E+01 i FH 53 45736 11/16/98 Cs-137' 8.75E+00 1.27E+01 4.63E+01 ! FH 53 45736 11/16/98 Fe-59 2.51E+01 4.99E+01 1.86E+02 FH 53 45736 11/16/98 I-131 8.28E+01 6.93E+01 2.26E+02 q FH 53 45736 11/16/98 K-40 2.46E+03 4.44E+02 7.57E+02
- FH 53 45736 11/16/98 Mn-54 -1.36E+01 1.26E+01 5.19E+01 FH 53 45736 11/16/98 Ru-103 -2.89E+01 1.69E+01 6.97E+01 i
~ FH 53 45736 11/16/98 Ru-106 5.00E+01 1.06E+02 3.97E+02 j FH 53 45736 11/16/98 Sb-124 2.99E+00 2.85E+01 1.29E+02 l FH '53 45736 11/16/98 Se-75 -0.36E+00 1.28E+01 4.60E+01 I FH 53 45736 11/16/98 Th-232 1.04E+02 5.80E+01 1.78E+02 FH 53 45736 11/16/98 Zn-65 1.55E+01 3.01E+01 1.11E+02 FH 53 45736 11/16/98 Zr-95 1.78E+01 2.37E+01 8.19E+01 l i l 5 i
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
4
i i I Seabrook Nuclear Power Station ! Radiological Environmental Monitoring Program j Summary of 1998 Data j SAMPLE CONC. STD DEV. MDC ' TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) American Lobster (Homarus americanus) I HA 04 42325 05/21/98 Ag-110M -1.60E+01 9.32E+00 4.04E+01 HA 04 42325 05/21/98 Ba-140 4.16E+00 1.33E+01 5.28E+01 RA 04 42325 05/21/98 Be-7 -2.01E+01 7.41E+01 2.67E+02 HA 04 42325 05/21/98 Ce-141 0.73E+00 1.02E+01 3.30E+01 HA 04 42325 05/21/98 Ce-144 -8.73E+00 3.48E+01 1.14E+02 HA 04 42325 05/21/98 Co-57 -4.20E+00 4.45E+00 1.50E+01 WL 04 42325 05/21/98 Co-58 -1.40E+01 8.51E+00 3.47E+01 HA 04 42325 05/21/98 Co-60 -2.62E+01 9.24E+00 4.65E+01 HA 04 42325 05/21/98 Cr-51 5.67E+01 8.04E+01 2.67E+02 HA 04 42325 05/21/98 Cs-134 -1.54E+00 8.21E+00 2.87E+01 HA 04 42325 05/21/98 Cs-137 -3.01E+00 9.53E+00 3.62E+01 HA 04 42325 05/21/98 Fe-59 -6.57E+00 2.29E+01 9.34E+01 , HA 04 42325 05/21/98 I-131 -4.63E+01 2.12E+01 8.40E+01 ! HA 04 42325 05/21/98 K-40 1.98E+03 2.58E+02 5.23E+02
- HA 04 42325 05/21/98 Mn-54 5.67E+00 ' 57E+00
. 2.55E+01 HA 04 42325 05/21/98 Ru-103 -0.47E+00 6.95E+00 2.58E+01 HA 04 42325 05/21/98 Pu-106 -6.35E+01 7.07E+01 2.85E+02 1 HA. 04 42325 05/21/98 55-124 1.06E+01 2.41E+01 9.09E+01 j RA 04 42325 05/21/98 Se-75 -5.48E+00 8.65E+00 3.10E+01 j HA 04 42325 05/21/98 Th-232 1.84E+01 3.29E+01 1.14E+02 HA 04 42325 05/21/98 Zn-65 2.80E+01 1.69E+01 5.26E+01 RA 04 42325 05/21/98 Zr-95 1.13E+01 1.28E+01 4.30E+01 1
I s
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) HA 54 42289 05/20/98 Ag-110M -4.70E+00 8.84E+00 3.20E+01 HA 54 42289 05/20/98 Ba-140 -7.76E+00 1.57E+01 5.98E+01 HA 54 42289 05/20/98 Be-7 -1. 3 4 E+ 02 5.53E+01 2.20E+02 HA 54 42289 05/20/98 Ce-141 -5.89E+00 9.18E+00 3.02E+01 HA 54 42289 05/20/98 Ce-144 0.98E+00 3.37E+01 1.07E+02 HA 54 42289 05/20/98 Co-57 1.37E+00 3.78E+00 1.19E+01 HA 54 42289 05/20/98 Co-58 -1.27E+01 6.33E+00 2.54E+01 HA 54 42289 05/20/98 Co-60 -1.89E+00 6.13E+00 2.39E+01 HA 54 42289 05/20/98 Cr-51 -2.36E+01 6.88E+01 2.39E+02 HA 54 42289 05/20/98 Cs-134 -1.77E+00 6.83E+00 2.32E+01 HA 54 42289 05/20/98 Cs-137 -1.09E+01 7.22E+00 2.86E+01 HA 54 42289 05/20/98 Fe-59 -5.71E+01 2.13E+01 9.32E+01 HA 54 42289 05/20/98 I-131 -1.27E+01 1.92E+01 6.89E+01 HA 54 42289 05/20/98 K-40 2.52E+03 2.12E+02 3.85E+02 *- i HA 54 42289 05/20/98 Mn-54 -4.98E+00 5.61E+00 2.11E+01 Ru-103 { HA 54 42289 05/20/98 -8.01E+00 6.35E+00 2.43E+01 HA 54 42289 05/20/98 Ru-106 9.75E+01 7.26E+01 2.42E+02 HA 54 42289 05/20/98 Sb-124 1.09E+00 1.49E+01 5.66E+01 1 HA 54 42289 05/20/98 Se-75 -4.07E+00 7.69E+00 2.6dE+01 J HA 54 42289 05/20/98 Th-232 -6.49E+00 2.49E+01 8.93E+01 HA 54 42289 05/20/98 Zn-65 4.32E+01 3.48E+01 1.24E+02 HA 54 42289 05/20/98 Zr-95 0.00E+00 1.11E+01 4.18E+01 HA 54 45786 11/24/98 Ag-110M -5.54E+00 1.12E+01 4.41E+01 HA 54 45786 11/24/98 Ba-140 -2.00E+00 1.14E+01 4.84E+01 HA 54 45786 11/24/98 Be-7 4.52E+01 7.12E+01 2.44E+02 HA 54 45786 11/24/98 Ce-141 -3.40E+01 1.19E+01 4.53E+01 HA 54 45786 11/24/98 Ce-144 -1.86E+01 3.73E+01 1.27E+C2 HA 54 45786 11/24/98 Co-57 6.88E+00 5.25E+00 1.59E+01 HA 54 45786 11/24/98 Co-58 6.11E+00 6.95E+00 2.35E+01 HA 54 45786 '11/24/98 Co-60 -1.23E+01 9.14E+00 3.93E+01 HA 54 45786 11/24/98 Cr-51 -2.84E+01 7.91E+01 2.83E+02 , HA 54 45786 11/24/98 Cs-134 -1.36E+00 8.69E+00 3.13E+01 l HA 54 45786 11/24/98 Cs-137 4.96E+00 9.79E+00 3.53E+01 ' HA 54 45786 11/24/98 Fe-59 2.63E+01 2.19E+01 7.20E+01 HA 54 45786 11/24/98 I-131 -1.64E+01 1.42E+01 5.53E+01 HA 54 45786 11/24/98 K-40 1.79E+03 2.56E+02 5.71E+02
- HA 54 45786 11/24/98 Mn-54 -2.56E+00 7.00E+00 2.69E+01 HA 54 45786 11/24/98 Ru-103 2.51E+00 7.69E+00 2.74E+01 HA 54 45786 11/24/98 Ru-106 6.84E+01 6.41E+01 2.23E+02 HA 54 45786 11/24/98 Sb-124 1.58E+01 1.71E+01 6.18E+01 MA 54 45786 11/24/98 Se-75 6.44E+00 1.07E+01 3.59E+01 MA 54 45786 11/24/98 Th-232 8.84E+00 2.72E+01 1.02E+02 HA 54 45786 11/24/98 Zn-65 -3.13E+00 1.65E+01 6.51E+01 HA 54 45786 11/24/98 Zr-95 -0.77E+00 1.17E+01 4.43E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
e Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) Mussel Body MU 06 42286 05/18/98 Ag-110M -1.99E+01 1.14E+01 4.79E+01 MU 06 42286 05/18/98 Ba-140 7.73E+00 1.45E+01 5.73E+01 MU 06 42286 05/18/98 Be-7 9.27E+01 7.78E+01 2.53E+02 MU 06 42286 05/18/98 Ce-141 -6.82E+00 1.24E+01 4.09E+01 MU 06 42286 05/18/98 Ce-144 4.59E+01 4.03E+01 1.23E+02 MU 06 42286 .05/18/98 Co-57 -5.89E+00 4.50E+00 1.55E+01 MU 06- 42286 05/18/98 Co-58 -1.23E+01 8.04E+00 3.39E+01 MU 06 42286 05/18/98 Co-60 0.00E+00 1.20E+01 4.65E+01' MU 06 42286 05/18/98 Cr-51 -1.91E+01 9.25E+01 3.25E+02 MU 06 42286 05/18/98 Cs-134 -1.19E+01 8.17E+00 3.12E+01 MU 06 42286 05/18/98 Cs-137 -1.45E+00 8.38E+00 3.24E+01 MU 06 42286 05/18/98 Fe-59 -0.93E+00 2.52E+01 1.01E+02 MU 06 42286 05/18/98 I-131 2.47E+01 3.31E+01 1.10E+02 MU 06 42286 05/18/98 K-40 8.54E+02 2.31E+02 6.65E+02
- MU 06 42286 05/18/98 Mn-54 -1.79E+01 7.82E+00 3.40E+01 MU 06 42286 05/18/98 Ru-103 6.49E+00 1.C3E+01 3.52E+01 MU 06 42286 05/18/98 Ru-106 3.96E+01 7.14E+01 2.59E+02 MU 06 42286 05/18/98 Sb-124 -2.18E+01 1.96E+01 9.65E+01 MU 06 42286 05/19/98 Se-75 1.26E+01 1.0dE+01 3.40E+01 l MU 06 42286 05/18/98 Th-232 5.42E+01 3.60E+01 1.15E+02 MU 06 42286 05/18/98 Zn-65 4.03E+01 4.08E+01 1.56E+02 MU 06 42286 05/18/98 Zr-95 2.10E+01 1.62E+01 5.14E+01 MU 06 45733 11/16/98 Ag-110M -3.91E+00 1.33E+01 5.43E+01 MU 06 45733 11/16/98 Ba-140 -1.44E+00 2.76E+01 1.26E+02 MU 06 45733 11/16/98 Be-7 1.09E+02 9.31E+01 3.09E+02 MU 06 45733 11/16/98 Ce-141 -4.15E+01 2.03E+01 7.45E+01 MU 06 45733 11/16/98 Ce-144 1.78E+01 5.92E+01 1.92E+02 MU 06 45733 11/16/98 Co-57 -3.50E+00 7.23E+00 2.45E+01 MU 06 45733 11/16/98 Co-58 1.47E+01 1.14E+01 3.63E+01 MU 06 45733 11/16/98 Co-60 2.24E+01 1.21E+01 3.42E+01 MU 06 45733 11/16/98 Cr-51 -7.39E+01 1.50E+02 5.50E+02 MU 06 45733 11/16/98 Cs-134 -0.57E+00 1.14E+01 4.09E+01 MU 06 45733 11/16/98 C3-137 6.91E+00 1.16E+01 4.27E+01 MU 06 45733 11/16/98 Fe-59 -2.79E+01 4.02E+01 1.77E+02 MU 06 45733 11/16/98 I-131 -6.63E+01 7.20E+01 2.75E+02 MU 06 45733 11/16/98 K-40 6.25E+02 2.99E+02 9.91E+02 MU 06 45733 11/16/98 Mn-54 1.49E+00 8.61E+00 3.35E+01 MU 06 45733 11/16/98 Ru-103 1.50E+01 1.44E+01 4.82E+01 MU 06 45733 11/16/98 Ru-106 -7.13E+01 7.88E+01 3.57E+02 MU 06 45733 11/16/98 Sb-124 -3.95E+01 2.70E+01 1.45E+02 MU 06 45733 11/16/98 Se-75 9.42E+00 1.44E+01 4.89E+01 MU 06 45733 11/16/98 Th-232 -3.29E+01 5.00E+01 1.97E+02 MU- 06 45733 11/16/98 Zn-65 -3.38E+01 2.92E+01 1.26E+02 MU 06 45733 11/16/98 Zr-95 2.10E+01 2.03E+01 6.76E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MU 09 42284 05/18/98 Ag-110M 6.00E+00 1.17E+01 3.96E+01 MU. 09 42284 05/18/98 Ba-140 -5.65E+01 2.17E+01 9.94E+01 MU 09 42284 05/18/98 Be-7 1.35E+01
- i.17E+01 2.49E+02 MU 09 42284 05/18/98 Ce-141 -1.75E+01 1.21E+01 4.10E+01 MU 09 42284 05/18/98 Ce-144 7.04E+01 3.91E+01 1.15E+02 MU 09 42284 05/18/98 Co-57 5.86E+00 4.77E+00 1.44E+01 MU 09 42284 05/18/98 Co-58 4.24E+00 8.08E+00 2.75E+01 MU 09 42284 05/18/98 Co-60 6.30E+00 6.21E+00 2.16E+01 MU 09 42284 05/18/98 Cr-51 -1.12E+02 8.77E+01 3.20E+02 MU 09 42284 05/18/98 Cs-134 5.83E+00 8.26E+00 2.69E+01 MU 09 42284 05/18/98 Cs-137 5.15E+00 9.11E+00 3.22E+01 MU 09 42284 05/18/98 Fe-59 0.71E+00 2.19E+01 8.47E+01 KU 09 42284 05/18/98 I-131 1.23E+00 2.81E+01 9.79E+01 MU 09 42284 05/18/98 K-40 1.30E+03 2.14E+02 5.41E+02
- MU 09 42284 05/18/98 Mn-54 -3.77E+00 7.52E+00 2 . ~2 7 E+ 01 MU 09 42284 05/18/98 Ru-103 -2.21E+00 9.10E+00 3.26E+01 MU 09 42284 05/18/98 Ru-106 -8.79E+01 8.22E+01 3.19E+02 MU 09 42284 05/18/98 Sb-124 -9.29E+00 2.30E+01 9.06E+01 MU 09 42284 05/18/98 Se-75 -7.72E+00 9.11E+00 3.25E+01 MU 09 42284 05/18/98 Th-232 -9.01E+00 3.38E+01 1.22E+02 MU 09 42284 05/18/98 Zn-65 1.17E+01 1.72E+01 5.70E+01 MU 09 42284 05/18/98 Zr-95 -2.13E+01 1.55E+01 5.96E+01 MU 09 45783 11/17/98 Ag-110M 1.53E 00 1.44E+01 5.33E+01 MU 09 45783 11/17/98 Ba-140 -8.89E 00 7.95E+00 6.11E+01 MU 09 45783 11/17/98 Be-7 -2.14E+01 9.15E+01 3.43E+02 j MU 09 45783 11/17/98 Ce-141 8.01E+00 1.52E+01 4.85E+01 MU 09 45783 11/17/98 Ce-144 -4.32E+00 4.75E+01 1.58E+02 MU 09 45783 11/17/98 Co-57 1.89E+00 6.09E+00 1.97E+01 MU 09 45783 11/17/98 Co-58 3.50E+00 1.20E+01 4.28E+01 MU 09 45783 11/17/98 Co-60 -1.07E+01 1.14E+01 5.08E+01 MU 09 45783 11/17/98 Cr-51 -1.64E+02 1.10E+02 4.31E+02 MU 09 45783 11/17/98 Cs-134 1,56E+01 1.20E+01 4.05E+01 MU 09 45783 11/17/98 Cs-137 -7.13E+00 1.04E+01 4.31E+01 I MU 09 45783 11/17/98 Fe-59 2.44E+01 2.78E+01 1.00E+02 MU 09 45783 11/17/98 I-131 1.02E+00 3.31E+01 1.20E+02 MU 09 45783 11/17/98 K-40 1.08E+03 2.57E+02 6.55E+02
- l MU 09 45783 11/17/98 Mn-54 -5.05E+00 9.36E+00 3.74E+01 i MU 09 45783 11/17/98 Ru-103 -6.38E+00 1.04E+01 4.12E+01 MU 09 45783 11/17/98 Ru-106 1.19E+02 1.03E+02 3.54E+02 MU 09 45783 11/17/98 Sb-124 1.48E+01 2.19E+01 8.42E+01 !
MU 09 45783 11/17/98 Se-75 3.70E+00 1.22E401 4.24E+01 j MU 09 45783 11/17/98 Th-232 4.72E+00 4.39E+01 1.62E+02 ! MU 09 45783 *1/17/98 Zn-65 6.35E+00 2.39E+01, 9.02E+01 l MU 09 45783 11/17/98 Zr-95 1.45E+01 2.10E+01f 7.16E+01 ] J
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE , CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MU 56 42288 05/18/98 Ag-110M -1.14E+01 1.34E+01 5.21E+01 MU 56 42288 05/18/98 Ba-140 2.40E+01 3.03E+01 1.05E+02 MU 56 42288 05/18/98 Be-7 -6.13E+01 9.24E+01 3.41E+02 MU 56 42288 05/18/98 Ce-141 8.42E+00 1.47E+01 4.58E+01 MU 56 42288 05/18/98 Ce-144 3.13E+01 4.40E+01 1.37E+02 MU 56 42288 05/18/98 Co-57 5.83E+00 5.96E+00 1.82E+01 MU 56 42288 05/18/98 Co-58 -4.88E+00 1.03E+01 3.88E+01 { MU 56 42288 05/18/98 Co-60 8.58E+00 1.15E+01 4.07E+01 MU '56 42288 05/18/98 Cr-51 -1.04E+01 1.08E+02 3.74E+02 MU 56 42288 05/18/98 Cs-134 3.83E+00 8.53E+00 2.76E+01 MU 56 42288 05/18/98 Cs-137 -1.79E+01 1.07E+01 4.48E+01 MU 56 42288 05/18/98 Fe-59 -1.57E+01 3.00E+01 1.25E+02 MU 56 42288 05/18/98 I-131 1.77E+01 3.60E+01 1.22E+02 MU 56 42288 05/18/98 K-40 7.81E+02 2.47E+02 7.53E+02
- MU 56 42288 05/18/98 Mn-54 -8.37E+00 9.91E+00 3.78E+01 MU 56 42288 05/18/98 Ru-103 -2.86E+01 1.24E+01 4.98E+01 1 MU 56 42288 05/18/98 Ru-106 -4.55E+01 9.22E+01 3.56E+02 (
MU 56 42288 05/18/98 Sb-124 1.36E+01 2.43E+01 9.11E+01 MU 56 42288 05/18/98 Se-75 -7.80E+00 1.16E+01 4.11E+01 MU 56 42288 05/18/98 Th-232 1.83E+00 4.17E+01 1.49E+02 MU 56 42288 05/18/98 Zn-65 2.06E+01 2.47E+01 8.09t+01 MU 56 42288 05/18/98 Zr-95 -1.87E+01 2.21E+01 8.77E+01 MU 56 45735 11/16/98 Ag-110M -1.66E+01 1.04E+01 4.33E+01 MU 56 45735 11/16/98 Ba-140 -7.03E+00 1.25E+01 5.94E+01 MU 56 45735 11/16/98 Be-7 1.12E+02 4.97E+01 1.33E+02 MU 56 45735 11/16/98 Ce-141 -7.01E+00 1.15E+01 4.00E+01 MU 56 45735 11/16/98 Ce-144 -8.03E+00 3.39E+01 1.14E+02 i MU 56 45735 11/16/98 Co-57 8.56E+00 5.02E+00 1.48E+01 MU 56 45735 11/16/98 Co-58 3.20E+00 7.35E+00 2.G1E+01 MU 56 45735 11/16/98 Co-60 7.55E+00 7.77E+00 2.70E+01 MU 56 45735 11/16/98 Cr-51 -6.46E+01 8.27E+01 3.07E+02 MU 56 45735 11/16/98 Cs-134 -0.96E+00 6.65E+00 2.40E+01 MU 56 45735 11/16/98 Cs-137 0.00E+00 7.28E+00 2.82E+01 MU 56 45735 11/16/98 Fe-59 -1.91E+01 2.44E+01 1.03E+02 MU 56 45735 11/16/98 I-131 5.00E+01 2.71E+01 8.28E+01 MU 56 45735 11/16/98 K-40 1.23E+03 2.19E+02 5 50E+02
- MU 56 45735 11/16/98 Mn-54 -3.67E+00 7.77E+00 2.92E+01 MU 56 45735 11/16/98 Ru-103 -3.78E+00 9.07E+00 3.39E+01 MU 56 45735 11/16/98 Ru-106 -2.66E+01 6.77E+01 2.67E+02 MU 56 45735 11/16/08 Sb-124 -1.59E+01 1.99E+01 8.74E+01 ,
MU 56 45735 11/16/98 Se-75 1.17E+01 9.59E+00 3.10E+01 ) MU 56 45735 11/16/98 Th-232 -5.44E+01 2.47E+01 1.13E+02 1 MU 56 45735 11/16/98 Zn-65' -0.20E+00 1.75E+01 6.65E+01 MU 56 45735 11/16/98 Zr-95 2.22E+01 1.31E+01 4.16E+01 l l l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
1
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) MU 59 42285 05/20/98 Ag-110M 4.84E+00 1.17E+01 4.02E+01 MU 59 42285 05/20/98 Ba-140 -2.09E+01 1.69E+01 7.56E+01 MU 59 42285 05/20/98 Be-7 2.01E+01 7.58E+01 2.61E+02 MU 59 42285 05/20/98 Ce-141 1.97E+00 1.20E+01 3.77E+01 MU 59 42285 05/20/98 ce-144 -3.75E+01 3.41E+01 1.14E+02 MU 59 42285 05/20/98 Co-57 3.98E+00 3.85E+00 1.18E+01 MU 59 42285 05/20/98 Co-58 -3.23E+00 8.76E+00 3.19E+01 MU 59 42285 05/20/98 Co-60 0.00E+00 9.24E+00 3.63E+01 ! MU 59 42285 05/20/98 Cr-51 7.34E+01 8.18E+01 2.68E+02 l MU 59 42285 05/20/98 Cs-134 -3.32E+00 7.35E+00 2.61E+01 MU 59 42285 05/20/98 Cs-137 -5.33E+00 0.99E+00 3.45E+01 MU 59 42285 05/20/98 Fe-59 3.08E+01 2.62E+01 8.75E+01 MU 59 42285 05/20/98 I-131 2.94E+01 2.56E+01 8.29E+01' MU 59 42285 05/2C/98 K-40 4.41E+02 1.99E+02 6.37E+02 3 MU 59 42285 05/20/98 Mn-54 -1.87E+01 6.58E+00 2.P5E+01
~
MU 59 42285 05/20/98 Ru-103 2.40E+00 7.94E+00 2. *s d E+01 MU 59 42285 05/20/98 Ru ,106 -4.58E+01 7.24E+01 2.81E+02 MU 59 42285 05/20/98 Sb-124 -4.04E+01 1.78E+01 9.47E+01 MU 59 42285 05/20/98 Se-75 -8.49E+00 9.48E+00 3.36E+01 MU 59 42285 05/20/98 Th-232 1.67E+01 3.33E+01 1.15E+02 MU 59 42285 05/20/98 Zn-65 -1.24E+01 5.64E+01 2.06E+02 i MU 59 43285 05/20/98 Zr-95 1.25E+01 1.47E+01 4.84E+01 j MU 59 45784 11/23/98 Ag-110M -1.12E+01 1.55E+01 6.24E+01 MU 59 45784 11/23/98 Ba-140 2.33E+01 1.70E+01 5.32E+01 MU 59 45784 11/23/98 Be-7 1.90E+02 7.87E+01 2.13E+02 MU 59 45784 11/23/98 Ce-141 2.22E+01 1.20E+01 3.50E+01 1RJ 59 45784 11/23/98 Ce-144 -4.48E+01 4.25E+01 1.51E+02 MU 59 45784 11/23/98 Co-57 -1.24;..A 4.94E+00 1.91E+01 MU 59 45784 11/23/98 Co-58 7.40E+00 1.17E+01 4.07E+01 MU 59 45784 11/23/98 Co-60, -2.51E+01 1.32E+01 6.64E+01 MU 59 45784 11/23/98 Cr-51 -1.41E+02 9.09E+01 3.62E+02 MU 59 45784 11/23/98 Cs-134 1.69E+01 1.24E+01 3.36E+01 MU 59 45784 11/23/98 Cs-137 7.252s00 7.92E+00 2.89E+01 MU 59 45784 11/23/98 Fe-59 -5.05E+01 2.44E+01 1.31E+02 MU 59 45784 11/23/98 I-131 -5.81M+00 2.44E+01 8.85E+01 MU 59 45784 11/23/98 K-40 1. 0 '., E + 0 3 3.02E+02 8.40E+02
- MU 59 45784 11/23/98 Mn-54 2.10E+00 1.09E+01 4.00E+01 MU 59 45784 11/23/98 Ru-103 -1.12E+01 S.96E+00 3.86E+01 i MU 59 45784 11/23/98 Ru-106 1.75E+02 1.02E+02 3.28E+02 MU 59 45784 11/23/98 Sb-124 4.74E+00 3.19E+01 1.31E+02 MU 59 45784 11/23/98 Se-75 1.24E+01 1.04E+01 3.38E+01 MU 59 45784 11/23/98 Th-232 -1.07E+01 4.87E+01 1.84E+02 MU 59 45784 11/23/98 Zn-65 -7.38E+01 1.82E+01 1.37E+02 MU 59 45784 11/23/95 Zr-95 2.53E+00 1.46E+01 5.69E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l- i l-- Seabrook Nuclear Power Station ' l Radiological Environmental Monitoring Program ! Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) l Sediment (SE1 5 cm, SE2 10 cm, SE3 15 cm) ! SE1 02 42310 05/18/98 Ag-110M -1.06E+01 2.18E+01 8.09E+01 l SE1 02 42310 05/18/98 Ba-140 -2.47E+01 4.94E+01 2.07E+02 l SE1 02 42310 05/18/98 Be-7 -2.39E+02 1.59E+02 6.06E+02 SE1 02 42310 05/18/98 Ce-141 1.19E+01 3.71E+01 1.14E+02 SE1 02 42310 05/18/98 Ce-144 3.13E+01 1.05S+02 3.25E+02 SE1 02 42310 05/18/98 Co-57 -1.95E+01 1.32E+01 4.28E+01 l SE1 02 42310 05/18/98 Co-58 1.77E+01 1.77E+01 5.76E+01 I SE1 02 42310 05/18/98 Co-60 -0.39E+00 1.68E+01 6.67E+01 SE1 02 42310 05/18/98 Cr-51 2.89E+01 2.22E+02 7.50E+02 l SE1 02 42310 05/18/98 Cs-134 -4.15E+00 1.41E+01 5.5 M+01 ) l SE1 02 42310 05/18/98 Cs-137 -1.32E+01 1.92E+01 7.31E+01 SE1 02 42310 05/18/98 Fe-59 6.51E+01 7.25E+01 2.47E+02 i SEl- 02 42310 05/18/98 I-131 -5.37E+01 1.02E+02 3.63E+02 SE1 02 42310 05/18/98 K-40 1. 2 3 E+ 04 7.55E+02 8.76E+02
- l SE1 02 42310 05/18/98 Mn-54 7.95E+00 1.79E+01 6.02E+01 l
SE1 02 42310 05/18/98 Ru-103 1.96E+00 1.94E+01 6.82E+01 4 SE1 02 42310 05/18/98 Ru-106 -2.26E+01 1.41E+02 5.31E+02 ! SE1 02 42310 OE/18/98 Sb-124 -6.81E+00 3.86E+01 1.64E+02 SE1 02 42310 05/18/98 Se-75 -1.44E+01 2.21E+01 7.65E+01 l SE1 02 42310 05/18/98 Th-232 1.30E+03 8.97E+01 2.88E+02
- l SE1 02 42310 05/18/98 Zn-65 1.60E+01 1.11E+02 4.16E+02 l SE1 02 42310 '05/18/98 Zr-95 3.21E+01 3.91E+01 1.27E+02 SE2 02 42311 05/18/98 Ag-110M 1.65E+01 2.37E+01 8.11E+01 SE2 02 42311 05/18/98 Ba-140 -7.62E+00 3.77E+01 1.74E+02 SE2 02 42311 05/18/98 Be-7 -5.40E+01 1.64E+02 6.08E+02 1
, SE2 02 42311 05/18/98 Ce-141 4.88E+01 3.86E+01 1.16E+02 l SE2 02 42311 05/18/98 Ce-144 -1.03E+02 9.82E+01 3.29E+02 SE2 02 42311 05/18/98 Co-57 3.61E+00 1.32E+01 4.15E+01 SE2 02 42311 05/18/98 Co-58 1.32E+01 2.15E+01 7.31E+01 SE2 02 42311 05/18/98 Co-60 1.44E+01 1.86E+01 6.64E+01 l SE2 02 42311 05/18/98 Cr-51 2.46E+02 2.24E+02 7.30E+02 } SE2 02 42311 05/18/98 Cs-134 6.47E+00 1.57E+01 5.38E+01 t SE2 02 42311 05/18/98 Cs-137 -3.32E-06 1.84E+01 6.99E+01 SE2 02 42311 05/18/98 Fe-59 5.45E+01 7.43L+01 7 61E+02 SE2 02 42311 05/18/98 I-131 -1.51E+02 1.20E+02 ' 33E+02
.SE2 02 42311 05/18/98 K-40 1.21E+04 8.19E+02 7.78E+02
- SE2 02 42311 05/18/98 Mn-54 -2.72E+01 1.58E+01 6.72E+01 l SE2 02 42311 05/18/98 Ru-103 2.05E+01 2.32E+01 7.76E+01 i SE2 02 42311 05/18/98 Ru-106 1.20E+02 1.75E+02 6.21E+02 SE2 02 42311 05/18/98 Sb-124 2.35E+01 2.64E+01 9.93E+01 SE2 02 42311 05/18/98 Se-75 -4.91E+01 2.53E+01 9.48E+01 p SE2 02 42311 05/18/98 Th-232 8.34E+02 1.11E+02 3.40E+02 * !
SE2 02 42311 05/18/98 Zn-65 3.12E+01 1.08E+02 4.08E+02 ) SE2 02 42311 05/18/98 Zr-95 5.73E+01 3.88E+01 1.20E+02 l l i
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
F. I
^
l l f l 4 l I Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC l TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE3 02 42312 05/18/98 Ag '10M 2.81E+01 2.11E+01 6.62E+01 SE3 02 42312 05/18/98 Ba 140 -3.12E+01 3.92E+01 1.72E+02 SE3 02 42312 05/18/98 Be-7 -1.87E+02 1.20E+02 4.85E+02 SE3 02 42312 05/18/98 Ce-141 -4.57E+00 3.04E+01 9.75E+01 SE3 02 42312 05/18/98 Ce-144 1.16E+02 8.75E+01- 2.63E+02 SE3 02 42312 05/18/90 Co-57 -2.40E+01 1.17E+01 3.99E+01 SE3 02 42312 05/18/98 Co-58 -4.68E+00 1.47E+01 5.46E+01 SE3- 02 42312 05/18/98 Co-60 2.35E+01 1.31E+01 3.92E+01 SE3 02 42312 05/18/98 Cr-51 1.21E+02 1.93E+02 6.43E+02 SE3 02 42312 05/18/98 Cs-134 -8.84E+00 1.26E+01 4.61E+01 SE3 02 42312 05/18/98 Cs-137 1.00E+01 1.12E+01 3.97E+01 SE3 02 42312 05/18/98 Fe-59 8.49E+01 4.64E+01 1.40E+02 l SE3 02 42312 05/18/98 I-131 6.10E+01 8.26E+01 2.78E+02 i SE3 02 42312 05/18/98 K-40 1.51E+04 7.48E+02 5.55E+02
- i SE3 02 42312 05/18/98 Mn-54 0.00E+00 1.49E+01 5.27E+01 SE3. 02 42312 05/18/98 Ru-103 5.80E+00 1.57E+01 5.55E+01 L SE3 02 42312 05/18/98 Ru-106 4.33E+01 1.33E+02 4.86E+02
- SE3 02 42312 05/18/98 Sb-124 -2.28E+00 2.680+01 1.16E+02 i
SE3 02 42312- 05/18/98 Se-75 1.33E+01 2.01E+01 6.65E+01 SE3 02 42312 05/18/98 Th-232 6.80E+02 7.40E+01 2.88E+02
- SE3 02 42312 05/18/98 Zn-65 6.65E+01 7.86E+01 2.86E+02 SE3 02 42312 05/18/98 Zr-95 -3.27E+01 3.62E+01 1.42E+02 i
l i l l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
r 1 e i Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program { l- Summary of 1998 Data ) { SAMPLE CONC. STD DEV. MDC l TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) j ___.___________________.________________________________________________________ 1 L SE1 02 45743 11/16/98 Ag-110M -3.04E+01 3.59E+01 1.41E+02 i SE1 02 45743 11/16/98 Ba-140 -2.84E+02 4.26E+02 1.67E+03 [ SE1 02 45743 11/16/98 Be-7 2.29E+02 2.84E+02 9.50E+02 ' SE1 02 45743 11/16/98 Ce-141 3.24E+01 7.61E+01 2.37E+02 SE1 .02 45743_ 11/16/98 Ce-144 -1.80E+02 1.77E+02 5.78E+02 SE1 02 45743 11/16/98 Co-57 -1.53E+01 2.17E+01 7.05E+01 . SE1 02 45743 11/16/98 Co-58 -1.80E+01 2.21E+01 8.99E+01 ( SE1 02 45743 11/16/98 Co-60 1.92E+01 2.27E+01 7.84E+01 ! SE1 02 45743 11/16/98 Cr-51 -1.48E+03 4.51E+02 1.78E+03 i SE1 02 45743 11/16/98 Cs-134 9.85E+00 2.36E+01 7.93E+01 ,
.SE1 02 (5743 11/16/98 Cs-137 5.12E+01 2.70E+01 8.58E+01 !
SE1 02 .5743 11/16/98 Fe-59 5.91F+01 1.04E+02 3.64E+02 SE1 02 45743 11/16/98 I-131 2.77E+02 3.60E+02 1.20E+03 SE1 02 45743 11/16/98 K-40 1.24E+04 9.04E+02 1.02E+03
- 9 SE1 02 45743 11/16/98 Mn-54 3.46E+00 1.80E+01 6.59E+01 !
SE1 02 45743 11/16/98 Ru-103 -6.49E+01 3.35E+01 1.37E+02 l SE1 02 45743 11/16/98 Ru-106 3.83E+02 2.54E+02 8.39E+02 i SE1 02 45743 11/16/98 Sb-124 3.56E+01 4.37E+01 1.67E+02 j SE1 02 45743 11/16/98 Se-75 -6.32E+00 3.47E+01 1.20E+02 l l SE1 02 45743 11/16/98 Th-232 1.57E+03 1.30E+02 3.55E+02 * ! SE1 02 '45743 11/16/98 Zn-65 -6.42E+01 1.58E+02 5.79E+02 S1 02 45743 11/16/98 Zr-95 8.45E+01 5.66E+01 1.75E+02 l . SE2 02 45744 11/16/98 Ag-110M -1.46E+01 2.79E+01 1.07E+02 j SE2 02 45744 11/16/98 Ba-140 8.85E+01 3.75C+02 1.33E+03 SE2 02 45744 11/16/98 Be-7 3.43E+02 2.29E+02 7.26E+02 SE2 02 45744 11/16/98 Ce-141 2.31E+01 6.13E+01 1.93E+02 j SE2 02 45744 11/16/98 Ce-144 1.33E+02 1.48E+02 4.51E+02 1 SE2 02 45744 11/16/98 Co-57 2.18E+00 1.81E+01 5.74E+01 ; SE2 02 45744 11/16/98 Co-58 -8.17E+00 2.24E+01 8.58E+01 ! SE2 02 45744 11/16/98 Co-60 1.83E+01 1.69E+01 5.81E+01 ' SE2 02 45744 11/16/93 Cr-51 1.59E+02 3.60E+02 1.22E+03 SE2 02 45744 11/16/98 Cs-134 2.41E+01 1.72E+01 7.32E+01 SE2 02 45744 11/16/98 Cs-137 -3.20E+01 2.33E+01 9.61E+01 l' SE2 02 45744 11/16/98 Fe-59 2.67E+00 8.23E+01 3.18E+02 SE2 02 45744 11/16/98 I-131 -6.45E+01 3.28E+02 1.16E+03 SE2 02 45744 11/16/98 K-40 1.07E+04 8.26E+02 1.06E+03
- SE2 02 45744 11/16/98 Mn-54 1.09E+00 2.06E+01 7.42E+01 i SE2 02 45744 11/16/98 Ru-103 1.54E+01 2.92E+01 1.02E+02 SE2 02 45744 11/16/98 Ru-106 -3.17E+02 2.14E+02 8.80E+02 SE2 02 45744 11/16/98 Sb-124 4.04E+01 6.13E+01 2.23E+02 SE2 02 45744 11/16/98 Se-75 1.12E+01 2.93E+01 9.93E+01
'SE2 02 45744 11/16/98 Th-232 1.29E+03 1.09E+02 3.64E+02 * )
SE2 02 45744 11/16/98 Zn-65 -0.80E+00 1.49E+02 5.75E+02 i SE2 02 45744 11/16/98 Zr-95 1.06E+02 5.35E+01 1.67E+02 I l i
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
I La I
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pC1/kg) SE3 02- 45745 11/16/98 Ag-110M 1.61E+01 2.90E+01 9.81E+01 SE3 02 45745 11/16/98 Ba-140 -1.77E+02 3.59E+02 1.32E+03 SE3 02 45745 11/16/98 Be-7 -2.13E+02 2.17E+02 8.18E+02 SE3 02 45745 11/16/98 Ce-141 5.54E+01 5.33E+01 1.63E+02 SE3 02 45745 11/16/98 Ce-144 7.23E+01 1.32E+02 4.10E+02 SE3 02 45745 11/16/98 Co-57 1.15E+01 1.63E+01 5.02E+01 SE3 02 45745 11/16/98 Co-58 2.30E+00 2.26E+01 8.04E+01 SE3 02 45745 11/16/98 Co-60 -4.27E+00 1.82E+01 7.29E+01 SE3 02 45745 11/16/98 Cr-51 -6.38E+01 3.31E+02 1.15E+03 SE3 02 45745 11/16/98 Cs-134 -4.41E+00 1.46E+01 6.08E+01 SE3 02 45745 11/16/98 Cs-137 1.01E+01 1.94E+01 6.99E+01 SE3 02 45745 11/16/98 Fe-59 -6.52E+01 6.83E+01 2.91E+02 SE3 02 45745 11/16/98 I-131 -1.76E+02 2.61E+02 9.54E+02 SE3 02 45745 11/16/98 K-40 1.26E+04 8.09E+02 8.64E+02
- SE3 02 45745 11/16/98 Mn-54 2.47E+01 2.06E+01 6.55E+01 SE3 02 45745 11/16/98 Ru-103 3.62E+01 3.19E+01 1.04E+02 SE3 02 45745 11/16/98 Ru-106 8.90E+01 1.90E+02 6.82E+02 SE3 02 45745 11/16/98 Sb-124 1.70E+01 4.88E+01 1.88E+02 SE3 02 45745 11/16/98 Se-75 -3.32E+01 2.79E+01 1.01E+02 SE3 02 45745 11/16/98 Th-232 1.07E+03 1.03E+02 3.43E+02 * ,
SE3 02 45745 11/16/98 Zn-65 6.30E+01 5.34E+01 1.67E+02 ' SE3 02 45745 11/16/98 Zr-95 1.50E+02 7.64E+01 3.04E+02 ; t
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
L ._ .
1 Seabrook Nuclear Power Station i Radiological Environmental Monitoring Program l Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUOLIDE (pCi/kg) (pCi/kg) (pCi/kg) i SE1 07 42J16 05/18/98 Ag-110M 1.26E+01 2.10E+01 7.38E+01 ) SE1 07 42316 05/18/98 Ba-140 -1.64E+01 3.20E+01 1.70E+02 j SE1 07 42316 05/18/98 Be-7 -1.15E+02 1.40E+02 5.51E+02 ; SE1 07 42316 05/18/98 Ce-141 .-4.60E+01 2.43E+01 8.81E+01 l SE1 07 42316 05/18/98 Ce-144 -6.19E+01 7.20E+01 2.47E+02
'SE1 07 42316 05/18/98 Co-57 -5.51E+00 9.75E+00 3.26E+01 SE1 07 42316 05/18/98 Co-58 2.34E+01 1.84E+01 5.87E+01 l SE1 07 42316 05/18/98 Co-60 -1.66E+01 1.66E+01 7.78E+01 )
SE1 07 42316 05/18/98 Cr-51 4.78E+00 1.78E+02 6.33E+02 SE1. 07 Cs-134 9.28E+00 1.59E+01 ] 42316 05/18/98 5.34E+01 j SE1 07 42316 05/18/98 Cs-137 1.04E+01 1.51E+01 5.51E+01 ! SE1 07 42316 05/18/98 Fe-59 -3.75E+01 5.40E+01 2.38E+02 SE1 07 42316 05/18/98 I-131 2.92E+01 8.40E+01 2.98E+02 l SE1 07 42316 05/18/98 K-40 1.67E+04 9.80E+02 7.53E+02
- l SE1 07 42316 05/18/98 Mn-54 -9.54E+00 1.24E+01 5.24E+01 SE1 07 42316 05/18/98 Ru-103 -2.27E+01 1.87E+01 7.62E+01 SE1 07 42316 05/18/98 Ru-106 -5.96E+01 1.33E+02 5.41E+02 SE1 07 42316 05/18/98 Sb-124 3.60E+00 '4.23E+01 1.82E+02 SE1 07 42316 05/18/98 Se-75 -3.02E+01 1.76E+01 6.88E+01 l SE1 07 42316 05/18/98 Th-232 3.25E+02 1.06E+02 3.19E+02
- l SE1 07 42316 05/18/98 Zn-65 -6.52E+01 4.88E+01 2.01E+02 '
SE1 07 42316 05/18/98 Zr-95 -5.02E+01 2.66E+01 1.22E+02 SE2 07 42317 05/18/98 Ag-110M -2.66E+01 2.45E+01 1.01E+02 l SE2 07 4?317 05/18/98 Ba-140 -1.27E+01 3.18E+01 1.68E+02 SE2 07 42317 05/18/98 Be-7 -1.16E+01 1.35E+02 5.22E+02 SE2 07 42317 05/18/98 Ce-141 -1.18E+01 2.87E+01 9.90E+01 i SE2 07 42317 05/18/98 Ce-144 -2.12E+01 8.92E+01 3.01E+02 l SE2 07 '42317 05/18/98 Co-57 1.40E+01 1.15E+01 3.52E+01 l SE2 07 42317 05/18/98 Co-58 -1.76E+01 1.56E+01 6.91E+01 Co-60 -1.24E+01 SE2 07 42317 05/18/98 1.78E+01 7.85E+01 SE2 07 42317 05/18/98 Cr-51 2.13E+02 1.74E+02 5.69E+02 SE2 07 42317 05/18/98 Cs-134 -3.35E+00 1.60E+01 6.08E+01 SE2 07 42317 05/18/98 Cs-137 8.06E+00 1.71E+01 6.40E+01 SE2 07 42317 05/18/98 Fe-59 -3.74E+01 6.24E+01 2.66E+02 SE2 07 42317 05/18/98 I-131 1.47E+02 9.63E+01 3.04E+02 SE2 07 42317 05/18/98 K-40 1.66E+04 9.89E+02 5.38E+02
- SE2 07 42317 05/18/98 Mn-54 1.93E+01 1.80E+01 5.89E+01 SE2 07 42317 05/18/98 Ru-103 -3.90E+00 1.47E+01 6 07E+01 l SE2 07 42317 05/18/98 Ru-106 3.72E+01 1.52E+02 5.79E+02 .
SE2 07 42317 05/18/98 Sb-124 -1.84E+01 1.64E+01 1.26E+02 i SE2 07 42317 05/18/98 Se 2.82E+00 2.03E+01 7.20E+01 l SE2 07 42317 05/18/98 Th-232 3.10E+02 7.85E401 3.25E+02
- SE2 07 42317 05/18/98 In-65 -4.52E+01 2.91E+01 1.45E+02 SE2 07 42317 05/18/98 Zr-95 -1.76E+01 2.78E+01 1.24E+02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
1 l 0 i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l l SAMPLE CONC. STD DEV. MDC ) TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE3 07 42318 05/18/98 Ag-110M 2.98E+00 2.59E+01 9.40E+01 SE3 07 42318 05/18/98 Ba-140 8.98E+01 5.67E+01 1.70E+02 SE3 07 42318 05/18/98 Be-7 -1.93E+02 1.49E+02 6.15E+02 l' SE3 07 42318 05/18/98 Ce-141 -4.58E+01 2.88E+01 1.03E+02 SE3 07 42318 05/18/98 Ce-144 -4.19E+01 7.85E+01 2.67E+02 SE3 07 42318 05/18/98 Co-57 -2.10E+01 9.92E+00 3.65E+01 J SE3 07 42318 05/18/98 Co-58 -7.17E+00 2.25E+01 8.37E+01 SE3 07 42318 05/18/98 Co-60 1.43E+01 1.72E+01 6.18E+01 SE3 07 42318 05/18/98 Cr-51 8.20E+01 1.93E+02 6.72E+02 i SE3 07 42318 05/18/98 Cs-134 -6.26E+00 1.16E+01 4.63E+01 j SE3 07 42318 05/18/98 Cs-137 1.41E+01 1.53E+01 5.43E+01 1 SE3 07 42318 05/18/98 Fe-59 9.14E+00 4.86E+01 1.98E+02 SE3 07 42318 05/18/98 I-131 4.98E+01 9.42E+01 3.29E+02 ]
)
SE3 07 42318 05/18/98 K-40 1.65E+04 1.01E+03 1.09E+03 * ; SE3 07 42318 05/18/98 Mn-54 -1.02E+00 1.54E+01 5.83E+01 ! SE3 07 42318 05/18/98 Ru-103 2.30E+01 1.81E+01 5.90E+01 1 SE3 07 42318 05/18/98 Ru-106 6.52E+01 1.38E+02 5.17E+02 l SE3 07 42318 05/18/98 Sb-124 3.90E+01 3.51E+01 1.20E+02 ! SE3 07 42318 05/18/98 Se-75 9.49E+00 1.93E+01 6.62E+01 l SE3 07 42318 05/18/98 Th-232 2.27E+02 6.66E+01 2.03E+02
- SE3 07 42318 05/18/98 Zn-65 -3.86E+00 4.72E+01 1.79E+02 SE3 07 42318 05/18/98 Zr-95 0.00E+00 3.30E+01 1.23E+02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental' Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pC1/kg) (pCi/kg) (pCi/kg) SE1 07 45737' 11/17/98 Ag-110M -4.87E+00 1.87E+01 7.20E+01 SE1 07 45737 11/17/98 Ba-140 2.51E+02 1.95E+02 6.34E+02 SEl~ 07 45737 11/17/98 Be-7 1.83E+02 1.53E+02 5.01E+02 SE1 07 45737 11/17/98 Ce-141 -5.09E+01 2.89E+01 1.01E+02 SE1 07 45737 11/17/98 Ce-144 -1.06E+02 6.47E+01 2.27E+02 SE1 07 45737 11/17/98 Co-57 -1.80E+00 8.74E+00 2.84E+01 SE1 07 45737 11/17/98 Co-58 1.02E+01 1.62E+01 5.61E+01 SE1 07 45737 11/17/98 Co-60 -1.42E+01 2.27E+01 9.24E+01 SE1 07 45737 11/17/98 Cr-51 -1.99E+02 2.05E+02 7.64E+02 SE1 07 45737 11/17/98 Cs-134 1.15E+01 1.44E+01 4.72E+01 l SE1 07 45737 11/17/98 Cs-137 0.00E+00 1.50E+01 5.73E+01 l SE1 07 45737 11/17/98 Fe-59 3.42E+01 6.65E+01 2.43E+02 { SE1 07 45737 11/17/98 I-131 1.66E+02 1.60E+02 5.27E+02 . j SE1 07 45737 11/17/98 K-40 ~1.73E+04 9.38E+02 9.08E+02 * ; SE1 07 45737 11/17/98 Mn-54 -2.47E+01 1.32E+01 5.77E+01 j SE1 07 45737 11/17/98 Ru-103 3.88E+01 2.11E+01 6.46E+01 ! l SE1 07 45737 11/17/98 Ru-106 -2.30E+02 1.38E+02 5.87E+02 l SE1 07 45737 11/17/98 Sb-124 2.04E+01 3.64E+01 1.46E+02 l SE1 07 45737 11/17/98 Se-75 -2.47E+01 1.90E+01 7.00E+01 ] SE1 07 45737 11/17/98 Th-232 3.05E+02 7.23E+01 2.72E+02
- SE1 07 45737 11/17/98 Zn-65 -1.93E+01 9.11E+01 3.61E+02 SE1 07 45737 11/17/98 Zr-95 -1.54E+01 2.82E+01 1.11E+02 l SE2 07 45738 11/17/98 Ag-110M 1.48E+01 1.86E+01 6.43E+01
! SE2 07 45738 11/17/98 Ba-140' 2.99E+02 2.05E+02 6.53E+02 SE2 07 45738 11/17/98 Be-7 -10.0E+01 1.38E+02 5.46E+02 SE2 07 45738 11/17/98 Ce-141 1.51E+01 3.29E+01 1.04E+02 SE2 07 45738 11/17/98 Ce-144 -7.35E+01 7.22E+01 2.48E+02 l SE2 07 45738 11/17/98 Co-57 1.41E+01 1.01E+01 3.03E+01 SE2 07 45738 11/17/98 Co-58 -3.28E+01 1.60E+01 7.35E+01 SE2 07 45738 11/17/98 Co-60 -2.08E+01 1.65E+01 7.82E+01 SE2 07 45738 11/17/98 Cr-51 -1.10E+02 2.29E+02 8.32E+02 SE2 07 45738 11/17/98 Cs-134 3.25E+01 1.56E+01 4.51E+01 SE2 07 45738 11/17/98 Cs-137 1.64E+01 1.50E+01 5.19E+01 SE2 07 45738 11/17/98 Fe-59 -3.29E+01 7.19E+01 2.93E+02 SE2 07 45738 11/17/98 I-131 1.48E+01 1.69E+02 6.06E+02 r SE2 07 45738 11/17/98 K-40 1.64E+04 9.41E+02 6.82E+02
- SE2 07 45738 11/17/98 Mn-54 0.00E+00 1.67E+01 6.09E+01 SE2 07 45738 11/17/98 Ru-103 -2.45E+01 2.02E+01 8.23E+01 SE2 07 45738 11/17/98 Ru-106 -1.71E+02 1.34E+02 5.73E+02 SE2 07 45738 11/17/98 Sb-124 5.56E+01 4.10E+01 1.32E+02 SE2 07 15738 11/17/98 Se-75 -3.82E+01 1.79E+01 7.09E+01 SE2 07 45738 11/17/98 Th-232 4.65E+02 8.77E+01 2.76E+02
- SE2 07 45738 11/17/98 Zn-65 -6.39E+01 5.68E+01 2.22E+02 SE2 07 45738 11/17/98 Zr-95 -1.98E+00 3.49E+01 1.28E+02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I
~Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE. STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
SE3 07 45739 .11/17/98. Ag-110M -1.16E+01 2.06E+01 7.64E+01 SE3 07 '45739 11/17/98 Ba-140 -3.54E+01 2.60E+02 9.20E+02 SE3 07 45739 11/17/98 Be-7 -1.21E+02 1.54E+02 5.67E+02 SE3 07 45739 11/17/98 Ce-141 8.21E+00 3.22E+01 1.01E+02 SE3 07 45739 11/17/98 Ce-144 -8.04E+00 8.11E+01 2.56E+02 SE3 07 45739 11/17/98 Co-57 1.14E+01 1.06E+01 3.19E+01 SE3 07 45739 11/17/98 Co-58 9.72E+00 2.17E+01 7.27E+01 SE3 07 45739 11/17/98 Co-60 1.03E+01 1.90E+01 6.72E+01 SE3 07 45739 11/17/98 Cr-51 1.00E+02 2.08E+02 6.97E+02 SE3 07 45739 11/17/98 Cs-134 1.18E+01 1.25E+01 3.84E+01 SE3 07 45739 11/17/98 Cs-137 4.67E+00 1.51E+01 5.49E+01 SE3 07 45739 11/17/98 Fe-59 5.07E+00 l; 7.59E+01 2.76E+02 SE3 07 45739 11/17/98 I-131 2.83E+02 1.90E+02 6.01E+02 SE3 07 45739 11/17/98 K-40 1.53E+04 8.03E+02 1.01E+03
- SE3 07 45739 11/17/98 Mn-54 -1.63E+01 1.74E+01 5.62E+01 l SE3 07 45739 11/17/98 Ru-103 6.96E+00 1.94E+01 6.71E+01 SE3 07 45739 11/17/98 Ru-106 8.12E+01 1.28E+02 4.55E+02 SE3 07 45739 11/17/98 Sb-124 2.41E+01 3.21E+01 1.19E+02 SE3 07 45739 11/17/98 Se-75 5.96E+00 2.15E+01 7.13E+01 SE3 07 45739 11/17/98 Th-232 1.33E+02 8.08E+01 2.65E+02 SE3 07 45739 11/17/98 Zn-65 -7.62E+01 3.83E+01 1.51E+02 SE3 07 45739 11/17/98 Zr-95 3.96E+01 3.25E+01 1.10E+02
- Radioactivity detected in sample (i .e. , CONC > 3 STD. DEV. )
i
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Sununary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE1 08 42319 05/18/98 Ag-110M 6.40E+00 2.62E+01 9.46E+01 SE1 08 42319 05/18/98 Ba-140 -7.08E+01 4.83E+01 2.60E+02 SE1 08 42319 05/18/98 Be-7 -1.58E+02 1.26E+02 5.44E+02 SE1 08 42319 05/18/98 Ce-141 2.47E+01 3.16E+01 9.85E+01 l SE1 08 42319 05/18/98 Ce-144 -6.69E+00 9.36E+01 3.04E+02 1 SE1 08 42319 95/18/98 Co-57 1.73E+01 1.17E+01 3.51E+01 1 SE1 08 42319 15/18/98 Co-58 -1.91E+01 2.19E+01 8.69E+01 ; SE1 08 42319 tS/18/98 Co-60 -0.79E+00 2.14E+01 8.54E+01 ' SE1 08 42319 05/18/98 Cr-51 -1.72E+02 1.97E+02 7.48E+02 i SE1 08 42319 05/18/98 Cs-134 2.06E+01 1.32E+01 2.83E+01 SE1 08 42319 05/18/98 Cs-137 0.00E+00 1.85E+01 7.17E+01 SE1 08 42319 05/18/98 Fe-59 -2.53E+00 6.83E+01 2.73E+02 SE1 08 42319 05/18/98 I-131 8.99E+00 8.70E+01 3.19E+02 SE1 08 42319 05/18/98 K-40 2.03E+04 1.15E+03 5.94E+02
- l SE1 08 42319 05/18/98 Mn-54 1.09E+01 1.72E+01 5.98E+01 !
SE1 08 42319 05/18/98 Ru-103 -9.98E+00 1.98E+01 7.74E+01 SE1 08 42319 05/38/98 Ru-106 -6.78E+01 1.66E+02 6.60E+02 SE1 08 42319 05/18/98 Sb-124 2.90E+01 3.26E+01 1.23E+02 SE1 08 42319 05/18/98 Se-75 -1.59E+01 1.94E+01 7.23E+01 SE1 08 42319 05/18/98 Th-232 3.55E+02 1.11E+02 3.19E+02
- SE1 08 42319 05/18/98 Zn-65 -2.26E+01 5.55E+01 2.14E+02 SE1 08 42319 05/18/98 Zr-95 0.00E+00 4.98E+01 1.88E+02 SE2 08 42320 05/18/98 Ag-110M 4.29E+00 2.23E+01 8.17E+01 SE2 08 42320 05/18/98 Ba-140 4.25E+01 3.69E+01 1.24E+02 '
SE2 08 42320 05/18/98 Be-7 4.03E+02 1.39E+02 3.36E+02 SE2 08 42320 05/18/98 Ce-141 -3.79E+01 2.86E+01 1.03E+02 SE2 08 42320 05/18/98 Ce-144 -1.20E+02 8.10E+01 2.94E+02 SE2 08 42320 05/18/98 Co-57 -1.48E+00 1.14E+01 3.77E+01 SE2 08 42320 05/18/98 Co-58 -3.46E+00 1.86E+01 7.04E+01 SE2 08 42320 05/18/98 Co-60 -0.80E+00 1.64E+01 6.71E+01 SE2 08 42320 05/18/98 Cr-51 -5.74E+01 1.74E+02 6.55E+02 SE2 08 42320 05/18/98 Cs-134 -0.77E+00 1.36E+01 4.98E+01 SE2 08 42320 05/18/98 Cs-137 0.00E+00 1.57E+01 6.15E+01 SE2 08 42320 05/18/98 Fe-59 -3.86E+01 3.36E+01 1.81E+02 SE2 08 42320 05/18/98 I-131 3.34E+01 9.35E+01 3.32E+02 SE2 08 42320 05/18/98 K-40 1.99E+04 1.03E+03 4.93E+02
- SE2 08 42320 05/18/98 Mn-54 4.09E+01 1.69E+01 4.46E+01 SE2 08 42320 05/18/98 Ru-103 -2.79E+01 2.17E+01 8.78E+01 SE2 08 42320 05/18/98 Ru-106 9.58E+01 1.39E+02 5.07E+02 SE2 08 42320 05/18/98 Sb-124 -1.68E+01 1.51E+01 1.16E+02 SE2 08 42320 05/18/98 Se-75 -2.99E+01 1.94E+01 7.63E+01 SE2 08 42320 05/18/98 Th-232 1.73E+02 9.33E+01 2.99E+02 SE2 08 42320 05/18/98 Zn-65 3.17E+01 4.90E+01 1.72E+02 SE2 08 42320 05/18/98 Zr-95 8.58E+01 3.55E+01 1.00E+02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE3 08 42321 .05/18/98 Ag-110M 3.64E+01 2.86E+01 9.12E+01 SE3 08 42321 05/18/98 Ba-140 -2.54E+01 6.32E+01 2.80E+02 SE3 08 '42321 05/18/98 Be-7 2.49E+02 1.79E+02 5.74E+02 SE3 08 42321 05/18/98 Ce-141 3.10E+01 3.57E+01 1.11E+02 SE3 08 42321 05/18/98 Ce-144 -3.64E+01 8.39E+01 2.83E+02 SE3 08 42321 05/18/98 Co-57 -1.32E+01 1.10E+01 3.83E+01 SE3 08 42321 05/18/98 Co-58 1.72E+01 1.88E+01 6.39E+01 SE3 08 42321 05/18/98 Co-60 2.10E+01 2.26E+01 8.14E+01 SS3 08 42321 05/18/98 Cr-51 -1.30E+02 1.84E+02 7.11E+02 SE3 08 42321 05/18/98 Cs-134 -5.30E+00 1.45E+01 5.57E+01 SE3 08 42321 05/18/98 Cs-137- 8.59E+00 1.82E+01 6.82E+01 SE3 08 42321 05/18/98 Fe-59 -1.04E+02 8.03E+01 3.56E+02 SE3 08 42321 05/18/98 I-131 -2.17E+02 1.00E+02 4.29E+02 SE3 08 42321 05/18/98 K-40 2.08E+04 1.24E+03 1.22E+03
- SE3 08 42321 05/18/98 Mn-54 5.19E+00 1.33E+01 5.03E+01 SE3 08 42321 05/18/98 Ru-103 1.68E+01 2.47E+01 8.52E+01
, SE3 08 42321 05/18/98 Ru-106 -1.11E+02 1.43E+02 6.14E+02 l SE3 08 42321 05/18/98 Sb-124 -4.01E+01 2.63E+01 1.92E+02 SC3 08 42321 05/18/98 Se-75 -6.40E+00 2.12E+01 7.66E,01 SE3 08 42321 05/18/98 Th-232 2.23E+02 9.72E+01 2.76E+02 , SE3 08 42321 05/18/98 Zn-65 6.09E+00 5.47E+01 2.05E+02 ! SE3 08 42321 05/18/98 Zr-95 1.34E402 4.73E+01 1.20E+02 I I l l
- Radioactivit, detected in sample (i.e., CONC > 3 STD. DEV.)
p 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE1 08 45740 11/17/98 Ag-110M -1.19E+01 2.78E+01 1.10E+02 SE1 08 45740 11/17/98 Ba-140 -1.82E+02 2.44E+02 1.04E+03 SE1 08 45740 11/17/98 Be-7 2.21E+01 1.67E+02 6.33E+02 SE1 08 45740 11/17/98 Ce-141 2.91E+01 3.85E+01 1.22E+02 SE1 08 45740 11/17/98 Ce-144 -8.41E+01 8.99E+01 3.18E+02 SE1 08 45740 11/17/98 Co-57 9.96E+00 1.31E+01 4.13E+01 SE1 08 45740 11/17/98 Co-58 1.20E+01 1.93E+01 6.98E+01 SE1 08 45740 11/17/98 Co-60 2.31E+01 2.06E+01 7.05E+01 SE1 08 45740 11/17/98 Cr-51 2.32E+02 2.68E+02 9.05E+02 SE1 08 45740 11/17/98 Cs-134 1.86E+01 1.72E+01 5.59E+01 SE1 08 45740 11/17/98 Cs-137 -4.70E+00 1.24E+01 5.64E+01 SE1 08 45740 11/17/98 Fe-59 -9.63E+00 7.18E+01 3.03E+02 SE1 08 45740 11/17/98 I-131 -1.63E+02 2.31E+02 8.93E+02 SE1 08 45740 11/17/98 K-40 1.06E+04 8.87E+02 8.16E+02
- SE1 08 45740 11/17/98 Mn-54 3.20E+01 1.85E+01 5.45E+01 SE1 08 45740 11/17/98 Ru-103 -4.62E+01 2.42E+01 1.09E+02 SE1 08 45740 11/17/98 Ru-106 4.11E+01 1.23E+02 4.94E+02 SE1 08 45740 11/17/98 Sb-124 -2.48E+01 2.22E+01 1.71E+02 SE1 08 45740 11/17/98 Se-75 2.14E+01 2.08E+01 6.90E+01 SE1 08 45740 11/17/98 Th-232 2.32E+02 7.76E+01 3.09E+02 SE1 08 45740 11/17/98 Zn-65 -6.22E+01 4.47E+01 2.04E+02 SE1 08 45740 11/17/98 Zr-95 -2.82E+00 3.37E+01 1.34E+02 SE2 08 45741 11/17/98 Ag-110M -1.92E+01 2.98E+01 1.22E+02 SE2 08 45741 11/17/98 Ba-140 -4.56E+02 2.93E+02 1.31E+03 SE2 08 45741 11/17/98 Be-7 5.48E+01 1.62E+02 6.08E+02 SE2 08 45741 11/17/98 Ce-141 -2.45E+01 3.45E+01 1.21E+02 SE2 08 45741 11/17/98 Ce-144 -4.23E+00 8.83E+01 2.95E+02 SE2 08 45741 11/17/98 Co-57 -1.89E+01 9.70E+00 3.70Er01 SE2 08 45741 11/17/98 Co-58 -1.67E+01 2.51E+01 1.03E+02 SE2 08 45741 11/17/98 Co-60 4.98E+00 2.55E+01 1.04E+02 SE2 08 45741 11/17/98 Cr-51 -2.21E+02 2.29E+02 9.28E+02 SE2 08 45741 11/17/98 Cs-134 -2.13E+01 1.40E+01 6.29E+01 SE2 08 45741 11/17/78 Cs-137 -1.54E+01 1.99E+01 8.58E+01 -
SE2 08 45741 11/17/98 Fe-59 4.12E+01 7.51E+01 2.92E+02 SE2 08 45741 11/17/98 I-131 2.53E+02 2.12E+02 6.98E+02 SE2 08 45741 11/17/98 K-40 1.65E+04 1.23E+03 1.41E+03
- SE2 08 45741 11/17/98 Mn-54 3.43E+01 1.94E+01 5.63E+01 SE2 08 45741 11/17/98 Ru-103 -4.28E+01 2.67E+01 1.17E+02 SE2 08 45741 11/17/98 Ru-106 8.95E+01 1.55E+02 5.87E+02 SE2 08 45741 11/17/98 Sb-124 3.86E+01 4.82E+01 1.90E+02 SE2 08 45741 11/17/98 Se-75 3.93E+00 2.41E+01 8.52E+01 SE2 08 45741 11/17/98 Th-232 1.11E+02 9.19E+01 2.98E+02 SE2 08 45741 11/17/98 Zn 4.14E+01 5.34E+01 1.91E+02 SE2 08 45741 11/17/98 Zr-95 6.16E+01 4.93E+01 1.58E+02
- Radioactivity detected in sample (i.e. , CONC > 3 STD. DEV. ) j J
o ) l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE3 08 45742 11/17/98 Ag-110M 1.82E+01 3.22E+01 1.15E+02 SE3 08 45742 11/17/98 Ba-140 -2.25E+02 2.61E+02 1.15E+03
'SE3- 08 45742 11/17/98 Be-7 -3.47E+02 1.83E+02 8.47E+02 SE3 08 45742 11/17/98 Ce-141 -3.74E+01 4.15E+01 1.46E+02 l SE3 08 Ce-144 1.05E+02 3.66E+02 45742 11/17/98 -8.61E+01 SE3 08 45742 11/17/98 Co-57 -5.37E+00 1.27E+01 4.33E+01 SE3 08 45742 11/17/98 Co-58 -3.26E+01 2.45E+01 1.09E+02 SE3 08 45742 11/17/98 Co-60 -8.81E+00 1.97E+01 9.48E+01 SE3 08 45742 11/17/98 Cr-51 6.58E+02 2.98E+02 8.66E+02 i SE3 08 45742 11/17/98 Cs-134 2.29E+01 2.09E+01 6.78E+01 I SE3 08 45742 11/17/98 Cs-137 1.11E+01 2.07E+01 7.80E+01 l SE3 08 45742 11/17/98 Fe-59 4.77E+01 9.02E+01 3.45E+02 l SE3 08 .45742 11/17/98 I-131 2.01E+02 2.82E+02 9.63E+02 l SE3 08 45742 11/17/98 K-40 1.23E+04 1.08E+03 1.16E+03
- SE3 08 45742 11/17/98 Mn-54 -7.72E+00 1.92E+01 7.90E+01 SE3 08 45742 11/17/98 Ru-103 -1.66E+01 2.17E+01 9.52E+01 SE3 08 45742 11/17/98 Ru-106 -9.63E+01 1.80E+02 7.64E+02 SE3 08 45742 11/17/98 Sb-124 -3.14E+01 5.25E+01 2.81E+02 SE3 08 45742 11/17/98 Se-75 2.87E+00 2.52E+01 9.00E+01 SE3 08 45742 11/17/98 Th-232 2.17E+02 8.86E+01 2.27E+02 SE3 08 45742 11/17/98 Zn-65 -2.28E+01 1.41E+02 5.60E+02 SE3 08 45742 11/17/98 Zr-95 6.69E+00 3.87E+01 1.51E+02 l
i'
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN l END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) ' SE1 52 42313 05/18/98 Ag-110M -2.65E+01 3.12E+01 1.21E+02 SE1 52 42313 05/18/98 Ba-140 -1,87E+02 1.06E+02 4.55E+02 SEl' 52 42313 05/18/98 Be-7 -4.50E+01 2.80E+02 9.78E+02 SE1 52 42313 05/18/98 Ce-141 -7.43E+01 5.99E+01 1.93E+02 SE1 52 42313 05/18/98 Ce-144 -1.83E+02 1.54E+02 4.99E+02 I SE1 52 42313 05/18/98 Co-57 -2.58E+01 2.05E+01 6.63E+01 SE1 52 42313 05/18/98 Co-58 2.50E+01 2.60E+01 8.54E+01 SE1 52 42313 05/18/98 Co-60 -4.35E+01 2.22E+01 1.06E+02 i SE1 52 42313 05/18/98 Cr-51 -3.44E+02 3.28E+02 1.17E+03 l SE1 52 42313 05/18/98 Cs-134 8.23E+00 1.91E+01 7.17E+0] ! SE1 52 42313 05/18/98 Cs-137 -2.61E+01 3 . '. 8 E + 01 1.21E+02 SE1 52 42313 05/18/98 Fe-59 7.86E+01 8.73E+01 3.02E+02 SE1 52 42313 05/18/98 I-131 -1.24E+02 1.74E+02 6.17E+02 ; SE1 52 42313 05/18/98 K-40 1.01E+04 9.31E+02 1.77E+03
- SE1 52 42313 05/18/98 Mn-54 1.13E+00 3.15E+01 1.08E+02 )
i SE1 52 42313 05/18/98 Ru-103 -1.90E+01 2.89E+01 1.07E+02 SE1 52 42313 05/18/98 Ru-106 3.16E+02 2.41E+02 8.06E+02 SE1 52 42313 05/18/98 Sb-124 -2.43E+01 5.38E+01 2.39E+02 SE1 52 42313 05/18/98 Se-75 -5.40E+01 3.52E+01 1.26E+02 SE1 52 42313 05/18/98 Th-232 2.20E+03 1.36E+02 4.73E+02
- SE1 52 42313 05/18/98 Zn-65 1.12E+02 5.70E+01 1.63E+02 SE1 52 42313 05/18/98 Zr-95 9.11E+01 6.18E+01 2.04E+02 SE2 52 42314 05/18/98 Ag-110M 4.77E+00 2.48E+01 9.09E+01 SE2 52 42314 05/18/98 Ba-140 -5.80E+01 6.10E+01 2.80E+02 SE2 52 42314 05/18/98 Be-7 -7.98E+01 1.61E+02 6.23E+02 SE2 52 42314 05/18/98 Ce-141 -2.64E+01 3.34E+01 1.14E+02 SE2 52 42314 05/18/98 Ce-144 7.08E+01 9.84E+01 3.08E+02 SE2 52 42314 05/18/98 Co-57 -1.12E+01 1.10E+01 3.82E+01 SE2 52 42314 05/18/98 Co-58 -2.55E+01 1.37E+01 6.81E+01 SE2 52 42314 05/18/98 Co-60 -4.56E+00 1.52E+01 6.77E+01 SE2 52 42314 05/18/98 Cr-51 -1.11E+02 2.25E+02 8.26E+02 SE2 52 42314 05/18/98 Cs-134 2.50E+00 1.30E+01 4.77E+01 SE2 52 42314 05/18/98 Cs-137 -1.61E+01 1.71E+01 7.32E+01 SE2 52 42314 05/18/98 Fe-59 6.76E+01 6.20E+01 2.12E+02 SE2 52 42314 05/18/98 I-131 8.38E+01 1.14E+02 3.88E+02 SE2 52 42314 05/18/98 K-40 1.11E+04 8.72E+02 1.16E+03
- SE2 52 42314 05/18/98 Mn-54 3.27E+00 1.70E+01 6.22E+01 SE2 52 42314 05/18/98 Ru-103 -3.84E+00 2.01E+01 7.69E+01 SE2 52 42314 05/18/98 Ru-106 -3.13E+02 1.43E+02 6.77E+02 SE2 52 42314 05/18/98 Sb-124 -1.95E+01 1.74E+01 1.34E+02 SE2 52 42314 05/18/98 Se-75 -1.44E+01 1.94E+01 7.30E+01 SE2 52 42314 05/18/98 Th-232 4.49E+02 8.54E+01 3.34E+02
- i SE2 52 42314 05/18/98 Zn-65 -7.69E+01 4.51E+01 1.90E+02 l SE2 52 42314 05/18/98 Zr-95 -6.70E+01 3.37E+01 1.51E+02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i L ~
1 i; f Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE- CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pC1/kg) (pCi/kg) l SE3 52 42315 05/18/98 Ag-110M 5.41E+01 2.57E+01 6.91E+01 SE3- 52 42315 05/18/98 Ba-140 -1.37E+02 7.53E+01 3.75E+02 SE3 52 42315 05/18/98 Be-7 -2.52E+01 1.72E+02 6.50E+02 [ SE3 52 42315 05/18/98 Ce-141 4.63E+01 3.86E+01 1.27E+02 SE3 52 42315 05/18/98 Ce-144 -1.20E+02 1.15E+02 3.88E+02 SE3 52 42315 05/18/98 Co-57 -0.49E+00 1.48E+01- 4.76E+01 ! SE3 52 42315 05/18/98 Co-58 -2.06E+01. 1.83E*01 8.09E+01 SE3 52 42315 05/18/98 Co-60 -1.83E+00 2.27E+01 9.30E+01 l SE3 52 42315- 05/18/98 Cr-51 -3.30E+02 2.58E+02 9.81E+02 i SE3 52 42315 05/18/98 Cs-134 -1.88E+01 1.65E+01 6.37E+01 l SE3 52 42315 05/18/98 Cs-137 -3.20E+01 1.89E+01- 8.62E+01 SE3 52 42315 05/18/98 Fe-59 1.29E+02 8.15E+01 2.55E+02 SE3 52 42315 05/18/98 I-131 -6.60E+01 9.96E+01 3.90E+02 SE3 52 42315 05/18/98 K-40 1.28E+04 1.02E+03 1.31E+03
- SE3 52 42315 05/18/98 Mn-54 -2.27E+01 2.49E+01 9.62E+01
, SE3 52 42315 05/18/98 Ru-103 4.76E+01 2.83E+01 8.77E+01 l SE3 52 42315 05/18/98 Ru-106 1.18E+02 2.04E+02 7.39E+02 SE3 52 42315 05/18/98 Sb-124 9.60E+00 4.92E+01 1.91E+02 SE3 52 42315 05/18/98 Se-75 5.03E+00 2.42E+01 8.38E+01 SE3 52 42315 05/18/98 Th-232 1.01E+03 1.23E+02 3.31E+02
- SE3 52 42315 05/18/98 Zn-65 -2.22E+01 4.41E+01 1.76E+02 SE3 52 42315 05/18/98 Zr-95 0.00E+00 4.78E+01 1.85E+02 l l l
l l l l \
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i ( i I i' l
I' _ Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l ' SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pci/kg) (pci/kg) SE1 52 45746' 11/16/98 Ag-110M -1.35E+01 2.03E+01 7.05E+01 SE1 52 45746. 11/16/98 Ba-140 2.59E+02 2.46E+02 7.93E+02 SE1 52 45746 11/16/98 Be-7 -2.58E+02 1.62E+02 5.76E+02 SE1 52 .45746 11/16/98 Ce-141 7.14E+01 3.82E+01 1.12E+02 SE1 52 45746 11/16/98 Ce-144 -1.16E+02 8.77E+01 2.75E+02 I SEl' 52 '45746 11/16/98 Co-57 -1.85E+01 1.12E+01 3.52E+01 SE1 52 45746 11/16/98 Co-58 -2.89E+01 1.56E+01 5.83E+01 l SE1 52' 45746' 11/16/98 Co-60 1.59E+01 1.45E+01 4.97E+01 SE1 52 45746 11/16/98 Cr-51 -3.23E+02 2.33E+02 8.02E+02 l SE1 52 45746 11/16/98 Cs-134 8.85E+00 1.27E+01 4.05E+01 SE1 52 45746 11/16/98 Cs-137 -4.27E+00 1.62E+01 5.77E+01 SE1 52 45746 11/16/98 Fe-59 4.46E+01 5.85E+01 1.98E+02 SE1 52 45746 11/16/98 I-131 9.12E+01 '2.00E+02 6.56E+02 SE1 52 45746 11/16/98 K-40 1.19E+04 5.55E+02 7.21E+02
- SE1 52 45746 11/16/98 Mn-54 1.75E+01 1.55E+01 4.88E+01 l SE1 52 45746 11/16/98 Ru-103 -1.83E+01 1.96E+01 6.92E+01' 45746 11/16/98 Ru-106 SE1 52 3.73E+01 1.32E+02 4.62E+02 SE1 52 45746 11/16/98 Sb-124 -3.36E+01 4.20E+01 1.67E+02 i SE1 52 45746 11/16/98 Se-75 -5.39E+00 1.90E+01 6.31E+01 SE1 52 45746 11/16/98 Th-232 1.78E+03 7.47E+01- 2.47E+02
- SE1 52 45746 11/16/98 Zn-65 5.70E+01 9.38E+01 3.41E+02
.SE1 52 45746 11/16/98 Zr-95 7.31E+01 3.19E+01 9.36E+01 SE2 52 45747 11/16/98 Ag-110M 4.79E+00 1.36E+01 4.64E+01 SE2 52 45747 11/16/98 Ba-140 7.70E+01 1.72E+02 5.97E+02 SE2 52 45747 11/16/98 Be-7 -8.00E+01 9.97E+01 3.48E+02 SE2 52 45747 11/16/98 Ce-141 2.74E+01 2.67E+01 8.07E+01 SE2 52 45747 11/16/98 Ce-144 -3.72E+01 6.35E+01 1.98E+02 SE2 52 45747. 11/16/98 Co-57 7.43E+00 8.24E+00 2.48E+01 SE2; 52 45747 11/16/98 Co-58 -0.32E+00 1.22E+01 4.06E+01 L SE2 52 45747 11/16/98 Co-60 1.29E+01 9.46E+00 3.00E+01 45747 11/16/98 .SE2 52 Cr-51 6.36E+01 1.46E+02 4.79E+02 SE2 52 45747 11/16/98 Cs-134 -1.78E+01 8.38E+00 3.01E+01 SE2 52 45747 11/16/98 Cs-137 -2.79E+00 9.63E+00 3.47E+01 SE2 52 45747 11/16/98 Fe-59 -4.32E+01 3.93E+01 1.44E+02 SE2 52 45747 11/16/98 I-131 -1.40E+02 1.40E+02 4.82E+02 SE2 52 45747 11/16/98 K-40 1.23E+04 4.17E+02 3.79E+02
- SE2- 52 45747 11/16/98 Mn-54 2.17E+01 9.68E+00 '2.86E+01 SE2 52 45747 11/16/98 Ru-103 -1.82E+01 1.28E+01 4.63E+01 SE2 52 45747. 11/16/98 Ru-106 2.46E+01 8.86E+01 3.10E+02 SE2 52 45747 11/16/98 Sb-124 -2,14E+01 2.05E+01 8.55E+01 l SE2 52 45747 11/16/98 Se-75 0.55E+00 1.41E+01 4.64E+01 L SE2 52- 45747 11/16/98 .Th-232 8.78E+02 4.47E+01 1.52E+02
- l' SE2 .52 45747 11/16/98 Zn-65 1.28E+01 5.86E+01 2.19E+02 SE2 52 45747 11/16/98 Zr-95 -1.51E+01 2.11E+01 7.26E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
r-I i t-Seabrook Nuclear Power Station Radiological Environmental Monitoring Program
' Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
SE3 52 45748 11/16/98 Ag-110M -2.66E+01 1.10E+01 4.26E+01 l SE3 52 45748 11/16/98 Ba-140 -1.38E+02 1.47E+02 5.25E+02 SE3 52 45748 11/16/98 Be-7 -1.26E+02 8.84E+01 3.21E+02 SE3 52 45748 11/16/98 Ce-141 1.61E+01 2.40E+01 7.31E+01 ! SE3 52 45748 11/16/98 Ce-144 4.39E+01 5.83E+01 1.76E+02 45748 ~ 11/16/98 I SE3 52 Co-57 3.81E+00 7.42E+00 2.26E+01 SE3 52 45748 11/16/98 Co-58 -1.42E+01 9.88E+00 3.62E+01 SE3 52 45748 11/16/98 Co-60 -1.36E+01 8.60E+00 3.42E+01 SE3 52 45748 11/16/98 Cr-51 -1.77E+02 1.40E+02 4.89E+02 SE3 52 45748 11/16/98 Cs-134 5.78E+00 6.89E+00 2.52E+01 R SE3- 52 45748 11/16/98 Cs-137 -1.12E+01 9.39E+00 3.52E+01 SE3 52 45748 11/16/98 Fe-59 1.98E+01 3.26E+01 1.12E+02 SE3 52 45748 11/16/98 I-131 -5.95E+01 1.21E+02 4.15E+02 SE3 52 45748 11/16/98 K-40 1.19E+04 4.12E+02 4.01E+02
- SE3 52 45748 11/16/98 Mn-54 -5.80E+00 8.70E+00 3.02E+01 SE3 52 45748 11/16/98 Ru-103 -1.16E+01 1.26E+01 4.47E+01 SE3 52 45748 11/16/98 Ru-106 -1.31E+02 8.26E+01 3.14E+02 l SE3 52 45748 11/16/98 Sb-124 0.00E+00 1.78E+01 6.80E+01 l SE3 52 45748 11/16/98 Se-75 1.74E+01 1.25E+01 3.97E+01 SE3 52 45748 11/16/98 Th-232 7.54E+02 4.28E+01 1.41E+02
- SE3 52 45748 11/16/98 Zn-65 6.04E+00 1.94E+01 6.36E+01 SE3 52 45748 11/16/98 Zr-95 1.12E+01 2.22E+01 7.73E+01 l
i l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Sunmary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE1 57 42322 05/20/98 Ag-110M 1.34E+01 2.54E+01 9.15E+01 SE1 57 42322 05/20/98 Ba-140 -1.30E+02 5.97E+01 3.19E+02 SE1 57 42322 05/20/93 Be-7 7.80E+01 1.65E+02 5.96E+02 SE1 57 42322 05/20/98 Ce-141 2.14E+01 3.36E+01 1.07E+02 SE1 57 42322 05/20/98 Ce-144 -1.89E+02 1.01E+02 3.69E+02 . SE1 57 42322 05/20/98 Co-57 -1.18E+01 1.34E+01 4.60E+01 ! SE1 57 42322 05/20/98 Co-58 -1.21E+01 1.57E+01 7.09E+01 , l SE1 57 42322 05/20/98 Co-60 1.10E+01 2.09E+01 7.99E+01 l SE1 57 42322 03/20/98 Cr -2.42E+02 2.23E+02 8.74E+02 j I SE1 57 42322 05/20/98 Cs-134 -1.92E+01 1.69E+01 6.90E+01 i SE1 57 42322 05/20/98 Cs-137 0.54E+00 1.19E+01 5.19E+01 ! SE1 57- 42322 05/20/98 Fe-59 1.14E+01. 8.15E+01 3.16E+02 SE1 57 42322 05/20/98 I-131 -1.08E+02 1.01E+02 4.01E+02 SE1 57 42322 05/20/98 K-40 1.25E+04 9.70E+02 6.85E+02
- SE1 57 42322 05/20/98 Mn-54 -1.05E+01 1.95E+01 7.77E+01 l SE1 57 42327. 05/20/98 Ru-103 -8.07E+00 2.49E+01 9.54E+01 ;
321 57 42322 05/20/98 Ru-106 -8.39E+01 1.78E+02 7.31E+02 { i SE1 57 42322 05/20/98 Sb-124 3.00E+01 3.69E+01 1.43E+02 ! !- SE1 57 42322 05/20/98 Se-75 1.28E+01 2.23E+01 7.67E+01 f
- SE1 57 42322 05/20/98 Th-232 3.98E+02 1.03E+02 ".36E+02 *
(~ SE1 57 42322 05/20/98 Zn-65 -1.06E+02 3.94E+01 1.09E+02 l SE1 57 42322 05/20/98 Zr-95_ 8.64E+01 4.50E+01 3.30E+02 i SE2 57 42323 05/20/98 Ag-110M -1.93E+00 2.31E+01 9.22E+01 ( SE2 57 42323 05/20/98 Ba-140 -3,02E+01 4.01E+01 2.15E+02 I SE2 57 42323 .05/20/98 Be-7 1.50E+02 1.45E+02 4.93E+02 ! SE2 57 42323 05/20/98 Ce-141 3.34E+01 3.08E+01 9.61E+01 l SE2 57 42323 05/20/98 Ce-144 1.57E+02 1.18E+02 3.58E+02 l SE2 57 42323 05/20/98 Co-57 4.66E+00 1.26E+01 4.15E+01 SE2 57 42323 05/20/98- Co-58 4.60E+00 1.93E+01 7.32E+01 ! SE2 57 42323 05/20/98 Co-60 -2.71E+00 2.02E+01 8.54E+01 SE2 57 42323 05/20/98 Cr-51 2.09E+02 2.01E+02 6.72E+02 i SE2 57 42323 05/20/98 Cs-134 1.39E+01 1.58E+01 4.29E+01 ! SE2 57 42323 05/20/98 Cs-137 0.00E+00 2.01E+01 7.95E+01 SE2 57 42323 05/20/98 Fe-59 -1.13E+01 5.65E+01 2.44E+02 SE2 57 42323 05/20/98 I-131 -1.11E+02 9.11E+01 3.80E+02 SE2 57 42323 05/20/98 K-40 1.55E+04 1.07E+03 8.00E+02
- SE2 57 42323 05/20/98 Mn-54 -9.29E+00 1.68E+01 7.00E+01 SE2 57 42323 05/20/98 Ru-103 1.68E+01 1.45E+01 4.89E+01 l SE2 57 42323 05/20/98' Ru-106 -2.16E+02 1.56E+02 7.20E+02
( SE2 57 42323 05/20/98 Sb-124 -1.34E+01 3.37E+01 1.78E+02 i SE2 57 42323 05/20/98 Se-75 6.92E+00 2.12E+01 7.56E+01 i l SE2 57 42323 05/20/98 Th-232 3.12E+02' 1.25E+02 3.79E+02 l SE2 57 42323 05/20/98 Zn-65 -6.25E+01 4.49E+01 2.05E+02 l 05/20/98
~
SE2 57 42323 Zr-95 1.07E+01 3.21E+01 1.29E+02
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
E l. L-
t-l- I t b I' i- Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) ! SE3 57 42324 05/20/98 Ag-110M -2.37E+00 1.82E+01 8.28E+01 l SE3 57 42324 05/20/98 Ba-140 -1.89E+01 4.75E+01 2.51E+02 SE3 57 42324 05/20/98 Be-7 2.12E+02 1.92E+02 6.40E+02 l SE3 57 42324 05/20/98 Ce-141 4.19E+01 -3.77E+01 1.16E+02 l SE3 57 42324 05/20/98 Ce-144 1.49E+01 1.06E+02 3.49E+02 SE3' 57 42324 05/20/98 Co-57 1.56E+01 1.41E+01 4.33E+01 SE3 -57 42324 05/20/98- Co-58 -3.71E+00 2.01E+01 8.Y3E+01 i SE3 57 42324 05/20/98 Co-60 5.89E+00 1.69E+01 7 i4E+01 SE3 57 42324 05/20/98 Cr-51 -1.67E+02 1.92E+02 7.84E+02 SE3 57 42324 05/20/98 Cs-134 3.13E+01 1.57E+01 4.11E+01 SE3 57 42324 05/20/98 Cs-137 -1.18E+00 1.88E+01 7.83E+01 SE3 57 42324 05/20/98 Fe-59 -7.30E+00 9.05E+01 3.70E+02 SE3 57 42324 05/20/98 I-131 2.10E+02 1.04E+02 3.07E+02 SE3 57 42324 05/20/98 K-40 1.56E+04 1.23E+03 8.84E+02
- SE3 57 42324 05/20/98 Mn-54 -9.68E+00 2.20E+01 8.87E+01 l SE3 57 42324 05/20/98 Ru-103 4.21E+00 2.52E+01 9.46E+01 1 SE3 57 42324 05/20/98 Ru-106 -5.03E+01 1.81E+02 7.55E+02 J SE3 57- 42324 05/20/98 Sb-124 -3.01E+01 2.69E+01 -2.07E+02 i SE3 57 42324 05/20/98 Se-75 6.39E+00 2.47E+01 8.72E+01 SE3 57 42324 05/20/98 Th-232 3.60E+02 1.26E+02 3.48E+02 SE3 57 42324 05/20/98 Zn-65 -4.38E+01 6.55E+01 2.71E+02 I SE3 57 42324 05/20/98 Zr-95 -5.13E+01 4.44E+01 2.03E+02 )
l l 1 1 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.) !
l l
)
a l, Seabrook Nuclear Power Station Radiological Environmental Monitoring Program i Summary of 1998 Data SAMPLE CONC. STL DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SEl- 57 45787 11/23/98 Ag-110M -0.85E+00 1.85E+01 6.59E+01 SE1 57 45787 11/23/98 Ba-140 9.21E+01 1.09E+02 3.72E+02 SE1 57 45787 11/23/98 Be-7 -1.17E+01 1.10E+02 3.95E+02 SE1 57 45787 11/23/98 .Ce-141 1.06E+01 2.17E+01 6.77E+01 SE1 57 45787 11/23/98 Ce-144 -8.08E+01 5.77E+01 1.94E+02 SE1 57 45787 11/23/98 Co-57 6.68E+00 7.31E+00 2.23E+01 SE1 57 45787 11/23/98 Co-58 -1.02E+01 1.33E+01 5.11E+01 i SE1 57 45787 11/23/98 Co-60 3.35E+00 1.53E+01 5.83E+01 I SE1 57 45787 11/23/98 Cr-51 -8.89E+01 1.37E+02 4.95E+02 l SE1 57 45787 11/23/98 Cs-134 -1.20E+01 1.08E+01 4.04E+01 SE1 57 45787 11/23/98 Cs-137 1.44E+01 1.27E+01 4.32E+01 SE1 57 45787 -11/23/98 Fe-59 -2.07E+01 5.64E+01 2.15E+02 SE1 57 45787 11/23/98 I-131 -7.52E+00 7.83E+01 2.78E+02 SE1 15 7 45787 11/23/98 K-40 1.37E+04 6.96E+02 6.06E+02
- SE1 57 45787 11/23/98 Mn-54 -1.21E+01 1.15E+01 4.48E+01 SE1 57 45787 11/23/98 Ru-103 -9.19E+00 1.41E+01 5.30E+01 SE1 57' 45787 11/23/98 Ru-106 -7.15E+01 1.04E+02 4.11E+02 SE1 57 45787 11/23/98 Sb-124 -2.81E+01 2.76E+01 1.36E+02 SE1 57 45787 11/23/98 Se-75 -2.56E+00 1.33E+01 4.62E+01 SE1 57 45787 11/23/98 Th-232 2.93E+02 6,07E+01 2.86E+02
- l SE1 57 45787 11/23/98 Zn-65 5.16E+01 7.81E+01 3.01E+02 l SE1 57 45787 11/23/98 Zr-95 3.20E+01 2.18E+01 6.76E+01 SE2 57 45788 11/23/98 Ag-110M -7.35E+00 2.13E+01 7.85E+01 SE2 57 45788 11/23/98 Ba-140 1.00E+02 1.47E+02 5.07E+02 SE2 57 45788 11/23/98 Be-7 3.39E+02 1.42E+02' 4.12E+02 SE2 57 45788 11/23/98 Ce-141 7.22E+00 2.48E+01 7.85E+01 SE2 57 45788 11/23/98 Ce-144 -5.92E+01 6.83E+01 2.27E+02 SE2 57 45788 11/23/98 Co-57 -1.50E+01 9.18E+00 3.12E+01 SE2 57 45788 11/23/98 Co-58 -2.54E+00 1.75E+01 6.33E+01 SE2 57 45788 11/23/98 Co-60 -4.14E+00 1.44E+01 5.88E+01 SE2- 57 45788 11/23/98 Cr-51 4.47E+02 1.69E+02 4.89E+02 SE2 57 45788 11/23/98 Cs-134 -1.54E+01 1.11E+01 4.17E+01 SE2 57 45788 11/23/98 Cs-137 2.21E+01 1.54E+01 5.10E+01 SE2 57 45788 11/23/98 Fe-59 -5.46E+01 4.13E+01 1.94E+02 SE2 57 45788 11/23/98 I-131 -4.68E+01 9.79E+01 3.55E+02 SE2 57 45788 11/23/98 K-40 1.49E+04 8.15E+02 8.25E+02
- SE2 57 45788 11/23/98 Mn-54 -7.14E+00 1.31E+01 5.00E+01 SE2 57 45788 11/23/98 Ru-103 -1.19E+01 1.70E+01 6.47E+01 SE2 57 45788 11/23/98 Ru-106 1.55E+02 1.28E+02 4.33E+02 SE2 57 45788 11/23/98 Sb-124 -1.94E+01 2.37E+01 1.27E+02 SE2 57 45788 11/23/98 Se-75 -1.85E+01 1.56E+01 5.76E+01 SE2 57 45788 11/23/98 Th-232 3.78E+02 7.28E+01 2.34E+02
- SE2 57 45788 11/23/98 Zn-65 2.29E+01 4.39E+01 1.45E+02 SE2 57 45788 11/23/98 Zr-95 7.05E+01 3.22E+01 9.79E+01 l
l I' a
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary.of 1998 Data SAMPLE- CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) SE3 57 45789 ~ 11/23/98 Ag-110M 1.03E+00 1.01E+01 3.61E+01 SE3 57 45789 11/23/98 Ba-140 1.09E+02 1.12E+02 3.68E+02 SE3 57 45789 11/23/98 Be-7 6.47E+01 9.49E+01 3.17E+02 SE3 57 45789 11/23/98 Ce-141 -1.93E+01 1.94E+01 6.37E+01 SE3 57 45789 11/23/98 Ce-144 2.79E+00 5.18E+01 1.63E+02 SE3 57 45789 11/23/98 Co-57 7.63E+00 6.71E+00 2.03E+01 SE3 57 45789 11/23/98 Co-58 2.11E+00 1.06E+01 3.62E+01 SE3 57 45789 11/23/98 Co-60 -1.72E+01 '1.05E+01 4.33E+01 SE3 57 45789 11/23/98 Cr-51 2.66E+02 1.23E+02 3.74E+02 SE3 57 45789 11/23/98 Cs-134 -5.24E+01 2.42E+01 8.,75E+01 SE3 57 45789 11/23/98 Cs-137 -1.32E+00 9.82E+00 3.62E+01 SE3 57 45789 11/23/98 Fe-59 4.05E+01 3.14E+01 1.03E+02 SE3 57 45789 11/23/98 I-131 1.18E+01 6.60E+01 2.26E+02 SE3 57 45789 11/23/98 K-40 1.48E+04 5.45E+02 4.87E+02
- SE3 57 45789 11/23/98 Mn-54 1.06E+00 9.11E+00 3.13E+01 l
SE3 57 45789 11/23/98 Ru-103 2.39E+00 1.15E+01 3.98E+01 SE3 57 45789 11/23/98 Ru-106 -1.15E+01 8.53E+01 3.14E+02
-SE3 57 45789- 11/23/98 Sb-124 3.71E+00 1.09E+01 4.72E+01 SE3 57 45789 11/23/98 Se-75 -3.93E+00 1.13E+01 3.92E+01 SE3 57 45789 11/23/98 Th-232 2.91E+02 3.87E+01 9.64E+01
- j SE3 57 45789 11/23/98- Zn-65 -1.80E+01 2.70E+01 9.89E+01 i SE3' 57 45789 11/23/98 Zr-95 8.86E+00 1.8CE+01 6.79E+01 l l
l l l I l t
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l-L
l l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data j l SAMPLE CONC. STD DEV. MDC l TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) Food Crop TF 01 42684 06/18/98 Ag-110M -6.29E+00 1.30E+01 6.09E+01 TF 01 42684 06/18/98 Ba-140 -1.45E+01 1.30E+01 9.95E+01 TF 01 42684 06/18/98 Be-7 1.21E+02 1.12E+02 3.77E+02 TF 01 42684 06/18/98 Ce-141 2.26E+01 1.74E+01 5.31E+01 TF 01 42684 06/18/98 Ce-144 -9.09E+01 5.81E+01 2.17E+02 TF 01 42684 06/18/98 Co-57 3.88E+00 6.83E+00 2.23E+01 TF 01 42684 06/18/98 Co-58 1.52E+01 1.47E+01 4.92E+01 TF' 01 42684 06/18/98 Co-60 -1.28E+01 1.28E+01 6.87E+01 TF 01 42684 06/18/98 Cr-51 -2,23E+02 1.20E+02 5.15E+02 TF 01 42684 06/18/98 Cs-134 9.71E+00 1.35E+01 4.25E+01 1 TF 01 42684 06/18/98 Cs-137 0.00E+00 9.74E+00 4.28E+01 ) TF 01 42684 06/18/98 Fe-59 4.22E+01 4.80E+01 1.73E+02 l TF 01 42684 06/18/98 I-131 -4.09E+00 2.97E+01 1.17E+02 t TF 01 42684 06/18/98 K-40 1.49E+03 3.96E+02 1.00E+03
- TF 01 42684 06/18/98 Mn-54 1.08E+01 1.39E+01 4.84E+01 ;
TF 01 42684 06/18/98 Ru-103 -5.64E+00 1.32E+01 5.40E+01 i TF 01 42684 06/18/98 Ru-106 -6.70E+01 1.16E+02 5.03E+02 TF 01 42684 06/18/98 Sb-124 5.66E+00 4.40E+01 1.88E+02 ; TF 01 42684 06/18/98 Se-75 2.25E+01 1.20E+01 3.57E+01 i TF 01 42684 06/18/98 Th-232 -2.85E+01 4.83E+01 2.10E+02 TF 01 42684 06/18/98 Zn-65 1.72E+01 3.14E+01 1.20E+02 ) TF 01 42684 06/18/98 Zr-95 1.20E+01 2.22E+01 8.22E+01 l I l f I s r l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
- i. I
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TF 02 42685 06/18/98 Ag-110M -2.65E+01 1.34E+01 7.17E+01 TF 02 42685 06/18/98 Ba-140 -8.18E+00 2.06E+01 1.09E+02 TF 02- 42685 06/18/98 Be-7 4.55E+00 1.22E+02 4.55E+02 TF 02 42685 06/18/98 Ce-141 -3.44E+01 1.38E+01 5.64E+01 TF 02 42685 06/18/98 Ce-144 4.70E+01 4.53E+01 1.43E+02
.TF 02 42685 06/18/98 Co-57 -1.09E+01 6.30E+00 2.41E+01 TF 02 42685 06/18/98 Co-58 1.10E+01 1.15E+01 3.99E+01 TF 02 42685 06/18/98 Co-60 4.19E+00 1.83E+01 7.39E+01 TF 02 42685 06/18/98 Cr-51 -8.04E+00 1.04E+02 3.94E+02 TF 02 42685 -06/18/98 Cs-134 -6.07E+00 1.31E+01 5.29E+01 TF- 02 42685 06/18/98 Cs-137 -7.46E+00 1.18E+01 5.26E+01 TF 02 -42685- 06/18/98 Fe-59 1.2SE+01 3.71E+01 1.54E+02 TF 02 42685 06/18/98 I-131 -3.98E+01 3.51E+01 1.44E+02 TF 02 42685 06/18/98 K-40 1.39E+03- 3.79E+02 9.67E402
- TF 02 42685 06/18/98 MA-54 -1.01E+00 1.21E+01 4.81E+01 TF 02 42685 06/18/98 Ru-103 -1.24E+01 1.13E+01 5.06E+01 TF 02 42685 06/18/98 Ru-106 -1.26E+02 1.26E+0? 5.47E+02 TF 02 42685 06/18/98 Sb-124 -4.43E+01 4.35E+01 2.14E+02 TF 02 42685' 06/18/98 Se-75 -1.08E+01 1.44E+01 5.50E+01 TF 02 42685 06/18/98 Th-232 1.22E+02 6.48E+01 2.00E+02 TF 02 42685 06/18/98 Zn-65 3.51E+01 3.00E+01 1.02E+02 TF 02 42685 06/13/98 Zr-95 -5.65E+00 2.50E+01 9.92E+01 TF 02 43147 07/23/98 Ag-110M 6.99E+00 1.15E+01 3.94E+01 TF 02 43147 07/23/98 Ba-140 1.47E+01 1.23E+01 4.06E+01 TF 02 43147 07/23/98 Be-7 -1.24E+01 6.21E+01 2.27E+02 TF 02 43147 07/23/98 Ce-141 -5.44E+00 8.87E+00 2.95E+01 TF 02 43147 07/23/98 Ce-144 6.94E+01 3.58E+01 1.04E+02 TF 02 43147 07/23/98 Co-57 0.00E+00 4.10E+00 1.33E+01 TF 02 43147 07/23/98 Co-58 -1.02E+01 7.19E+00 3.02E+01 TF 02 43147 07/23/98 Co-60 -4.95E+00 1.172+01 4.73E+01 TF 02 43147 07/23/98 Cr-51 -6.62E+01 5.90E+01 2.22E+02 TF 02 43147 07/23/98 Cs-134 -5.29E+00 7.53E+00 2.97E+01 TF 02 43147 07/23/98 Cs-137 -8.83E+00 8.24E+00 3.43E+01 TF 02 43147 07/23/98 Fe-59 -7.95E+00 1.86E+01 8.06E+01 TF 02 43147 07/23/98 I-131 4.94E+00 1.00E+01 3.44E+01 TF 02 43147 07/23/98 K-40 1.49E+03 2.52E+02 5.82E+02
- TF 02 43147 07/23/98 Mn-54 -4.99E+00 6.97E+00 2.77E+01 TF 02 43147 07/23/98 Ru-103 -1.19E+01 8.03E+00 3.17E+01 TF 02 43147 07/23/98 Ru-106 -5.42E+01 6.91E+01 2.81E+02 TF 02 43147 07/23/98 Sb-124 9.81E+00 2.01E+01 7.76E+01 TF 02 43147 07/23/98 Se-75 -5.55E+00 8.15E+00 2.96E+01 TF 02 43147 07/23/98 Th-232 -2.18E+01 3.89E+01 1.45E+02 TF 02 43147 07/23/98 Zn-65 -4.01E+01 1.16E+01 8.07E+01 TF 02 43147 07/23/98 Zr-95 2.25E+00 1.36E+01 4.86E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
m --
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data i SAMPLE. CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pC1/kg) TF 02 '43683 08/20/98 Ag-110M 4.50E+01 1.84E+01 4.82E+01 TF 02 43683 08/20/98 Ba-140 -2.78E+00 1 37E+01 6.35E+01 TF 02 43683 08/20/98 Be-7 1.45E+02 7.26E+01 2.10E+02 TF 02 43683 08/20/98 Ce-141 1.13E+00 1.41E+01 4.59E+01 TF 02 43683 08/20/98 Ce-144 -4.50E+01 5.49E+01 1.86E+02 TF 02' 4'683 -08/20/98 Co-57 -0.26E+00 6.74E+00 2.20E+01 TF '02 43683 08/20/98 Co-58 1.01E+01 1.03E+01 3.48E+01 TF 02 43683- 08/20/98 Co-60 -4.42E+00 9.89E+00 4.76E+01 TF 02 43683 08/20/98 Cr-51 -7.51E+00 9.59E+01 3.43E+02 TF 02 43683 08/20/98 Cs-134 1.17E+01 1.34E+01 4.01E+01 TF 02 43683 08/20/98 Cs-137 -8.49E+00 1.27E+01 5.21E+01 TF- 02 43683 08/20/98 Fe-59 -1.52E+01 2.90E+01 1.31E+02 TF. 02 43683 08/20/98 I-131 -3.14E+00 1.88E+01 6.81E+01 TF 02 43683 08/20/98 K-40 2.43E+03 3.76E+02 7.13E+02
- TF 02 43683- 08/20/98 Mn 3.68E+00 1.06E+01 3.88E+01 TF 02 43683 08/20/98 Ru-103 8.10E+00 1.19E+01 4.10E+01 TF 02 43683 08/20/98 Ru-106 3.06E+01 8.80E+01 3.38E+02-TF 02 43683 08/20/98 Sb-124 9.69E+00 2.13E+01 9.13E+01 TF 02 43683 08/20/98 Se-75 2.56E+01 1.41E+01 4.59E+01 TF 02 43683 08/20/98 Th-232 -3.32E+01 3 57E+01 1.59E+02 TF 02 43683 08/20/98 Zn 1.59E+01- 2.44E+01 8.55E+01 TF 02 43683 08/20/98 Zr-95 6.47E+00 1.87E+01 6.82E+01 l
l
- Psdioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE MUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TF 03 42686 06/18/98 Ag-110M -1.45E+01 1.29E+01 5.66E+01 TF 03 42686 06/18/98 Ba-140 5.77E+00 2.74E+01 1.05E+02 TF 03 42686 06/18/98 be-7 1.06E+02 1.03E+02 3.40E+02 TF 03 42686 06/18/98 Ce-141 1.92E+01 1.91E+01 5.99E+01 TF 03 42686 06/18/98 Ce-144 2.95E+01 5.75E+01 1.84E+02 TF 03 42686 06/18/98 Co-57 0.63E+00 6.62E+00 2.25E+01 TF 03 42686 06/18/98 Co-58 -4.71E+00 1.22E+01 4.61E+01 TF 03 42686 06/18/98 Co-60 2.2SE+01 1.45E+01 4.51E+01 TF 03 42686 06/18/98 Cr-51 -4.24E+01 1.18E+02 4.24E+02 TF 03 42686 06/18/98 Cs-134 1.38E+01 1.41E+01 4.83E+01 TF 03 42686 06/18/98 Cs-137 -2.38E+00 1.19E+01 4.64E+01 TF 03 42686 06/18/98 Fe-59 1.70E+01 3.62E+01 1.31E+02 TF 03 42686 06/19/98 I-131 -0.75E+00 2.91E+01 1.05E+02 TF 03 42686 06/18/98 I-131 3.73E+00 6.11E+00 2.91E+01 TF 03 42686 06/18/98 K-40 4.15E+03 4.15E+02 6.81E+02
- TF 03 42686 06/18/98 Mn-54 4.33E+00 9.96E+00 3.54E+01 TF 03 42686 06/18/98 Ru-103 -9.11E+00 1.13E+01 1.46E+01 TF 03 42686 06/18/98 Ru-106 0.00E+00 9.06E+01 3.53E+02 TF 03 42686 06/18/98 Sb-124 2.21E+01 2.62E+01 9.56E+01 TF 03 42686 06/18/98 Se-75 -2.79E+01 1.49E+01 5.72E+01 TF 03 42686 06/18/98 Th-232 4.98E+01 5.35E+01 1.83E+02 TF 03 42686 06/18/98 Zn-65 -6.85E+00 2.95E+01 1.12E+02 TF 03 42686 06/18/98 Zr-95 -7.00E+00 1.92E+01 7.36E+01 TF 03 43148 07/23/98 Ag-110M 3.67E+00 1.09E+01 3.86E+01 TF 03 43148 07/23/98 Ba-140 -1.20E+01 1.01E+01 4.67E+^
TF 03 43148 07/23/98 Be-7 -2.62E+01 6.51E+01 2.39E+02 TF 03 43148 07/23/98 Ce-141 6.53E+00 9.91E+00 3.08E+01 TF 03 43148 07/23/98 Ce-144 -1.69E+01 4.04E+01 1.32E+02 TF 03 43148 07/23/98 Co-57 -2.58E+00 4.76E+00 1.57E+01 TF 03 43148 07/23/98 Co-58 -1.27E+01 6.87E+00 2.99E+01 TF 03 43148 07/23/98 Co-60 -2.11E+01 1.02E+01 4.81E+01 TF 03 43148 07/23/98 Cr-51 1.40E+01 6.64E+01 2.28E+02 TF 03 43148 07/23/98 Cs-134 9.04E+00 9.73E+00 2.97E+01 TF 03 43148 07/23/98 Cs-137 7.98E+00 8.59E+00 3.00E+01 TF 03 43148 07/23/98 Fe-59 -2.22E+01 2.33E+01 9.93E+01 TF 03 43148 07/23/98 I-131 3.59E+00 1.20E+01 4.09E+01 TF 03 43148 07/23/98 K-40 1.66E+03 2.77E+02 6.76L+02
- TF 03 43148 07/23/98 Mn-54 -5.06E+00 8.13E+00 3.09E+01 TF 03 43148 07/23/98 Ru-103 8.47E+00 7.46E+00 2.45E+01 TF 03 43148 07/23/98 Ru-106 7.95E+01 6.76E+01 2.31E+02 TF 03 43148 07/23/98 Sb-124 1.79E+01 2.02E+01 7.23E+01 TF 03 43148 07/23/98 Se-75 7.32E+00 8.93E+00 2.95E+01 TF 03 43148 07/23/98 Th-232 4.87E+00 3.26E+01 1.19E+02 TF 03 43148 07/23/98 Zn-65 -1.48E+01 1.92E+01 7.77E+01 TF 03 43148 07/23/98 Zr-95 -0.58E+00 1.23E+01 4.54E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
p L i - ! Seabrook Nuclear. Power Station Radiological Environmental Monitoring Program l Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) l TF 03 43684 -08/20/98 Ag-110M 1.14E+01 1.40E+01 4.86E+01 TF 03 43684 08/20/98 Ba-140 -6.64E+00 1.65E+01 7.32E+01 TF 03 43684 08/20/98 Be-7 4.97E+01 1.00E+02 3.52E+02 TF 03 43684 08/20/98 Ce-141 2.01E+00 1.44E+01 4.73E+01 TF 03 43684 08/20/98 Ce-144 1.13E+02 6.76E+01 2.00E+02 TF 03 43684 08/20/98 Co-57 1.28E+00 6.73E+00 2.21E+01 TF 03 43684 08/20/98 Co-58 -7.01E+00 1.09E+01 4.45E+01 TF 03 43684 08/20/98 Co-60 1.19E+01 1.54E+01 5.49E+01 1 TF 03 43684 08/20/98 Cr-51 -4.08E+01 9.37E+01 3.51E+02 / TF 03 43684 08/20/98 Cs-134 1.12E+01 1.17E+01 3.82E+01-TF 03 43684 08/20/98 Cs-137 1.59E+01 1.24E+01 4.21E+01 TF 03 43684 08/20/98 Fe-59 -1.90E+01 2.50E+01 1.21E+02 TF 03 43684 08/20/98 I-131 2.69E+01 1.77E+01 5.58E+01 TF 03 43684 08/20/98 K-40 1.92E+03 3.52E+02 8.00E+02
- TF 03 43684 08/20/98 Mn-54 6.02E+00 1.06E+01 3.79E+01 TF 03 43684 08/20/98 Ru-103 -1.99E+01 1.10E+01 4.75E+01 l TF 03 43684 08/20/98 Ru-106 2.42E+01 9.96E+01 3.83E+02 TF 03 43684 08/20/98 Sb-124 0.00E+00 1.55E+01 7.96E+01 TF 03 43684 08/20/98 Se-75 1.36E+01 1.30E+01 4.27E+01 TF 03 43684 08/20/98 Th-232 -1.72E+01 5.08E+01 1.97E+02 TF 03 43684 08/20/98 Zn-65 4.97E+01 3.48E+01 8.49E+01 TF 03 43684 08/20/98 Zr-95 2.14E+01 2.03E+01 6.71E+01 I
I I-l
- Radioactivity detected in sample (i . e . , CONC > 3 STD. DEV.)
l
l l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TF 06 42687 06/18/98 Ag-110M -1.80E+01 1.54E+01 6.64E+01 TF 06 42687 06/18/98 Ba-140 -1.04E+01 2.58E+01 1.14E+02 TF 06 42687 06/18/98 Be-7 3.48E+00 9.33E+01 3.48E+02 TF 06 42687 06/18/98 Ce-141 4.19E+00 1.60E+01 5.20E+01 TF 06 42687 06/18/98 Ce-144 9.42E+00 4.95E+01 1.63E+02 TF 06 42687 06/18/98 Co-57 4.16E+00 7.29E+00 2.31E+01 TF 06 42687 06/18/98 Co-58 5.02E+00 1.28E+01 4.60E+01 TF 06 42687 06/18/98 Co-60 -1.02E+01 1.25E+01 5.76E+01 TF 06 42687 06/18/98 Cr-51 1.23E+02 1.23E+02 4.04E+02 TF 06 42687 06/18/98 Cs-134 -2.32E+01 9.69E+00 4.44E+01 TF 06 42687 06/18/98 Cs-137 -1.99E+01 1.10E+01 5.16E+01 TF 06 42687 06/18/98 Fe-59 -1.74E+01 3.31E+01 1.50E+02 TF 06 42687 06/18/98 I-131 4.93E+00 3.17E+01 1.14E+02 TF 06 42687 06/18/98 K-40 1.66E+03 3.47E+02 8.35E+02
- TF 06 42687 06/18/98 Mn-54 -4.61E+00 7.76E+00 3.46E+01 TF 06 42687 06/18/98 Ru-103 -8.55E+00 1.29E+01 5.05E+01 TF 06 42687 06/18/98 Ru-106 4.80E+01 1.07E+02 4.00E+02 TF 06 42687 06/18/98 Sb-124 -3.49E+01 2.65E+01 1.42E+02 TF 06 42687 06/18/98 Se-75 -1.06E+01 1.21E+01 4.59E+01 TF 06 42687 06/18/98 Th-232 -1.20E+01 4.31E+01 1.72E+02 TF 06 42687 06/18/98 Zn-65 -1.58E+01 2.64E+01 1.13E+02 TF 06 42687 06/18/98 Zr-95 -1.15E+01 1.99E+01 8.62E+01 TF 06 43149 07/23/98 Ag-110M 6.12E+00 9.52E+00 3.22E+01 TF 06 43149 07/23/98 Ba-140 0.26E+00 6.91E+00 2.83E+01 TF 06 43149 07/23/98 'e-7 1.28E+02 6.15E+01 1.86E+02 TF 06 43149 07/23/98 Cc-141 5.58E+00 8.87E+00 2.76E+01 TF 06 43149 07/23/98 Ce 144 -5.55E+01 3.35E+01 1.15E+02 TF 06 43149 07/23/98 Co 57 -1.24E+00 3.79E+00 1.25E+01 TF 06 43149 07/23/98 Co- 5 8 4.65E+00 6.21E+00 2.09E+01 TF 06 43149 07/23/98 Co 60 3.52E+00 6.87E+00 2.53E+01 TF 06 43149 07/23/98 Cr-51 1.04E+01 5.80E+01 1.99E+02 TF 06 43149 07/23/98 Cs-134 -3.32E+00 7.07E+00 2.50E+01 TF 06 43149 07/23/98 Cs-137 2.51E+00 7.31E+00 2.67E+01 TF 06 43149 07/23/98 Fe-59 -5.95E+00 1.40E+01 5.71E+01 TF 06 43149 07/23/98 I-131 -5.24E+00 7.97E+00 2.97E+01 TF 06 43149 07/23/98 K-40 1.55E+03 2.29E+02 5.71E+02
- TF 06 43149 07/23/98 Mn-54 -1.88E+00 5.34E+00 2.05E+01 TF 06 43149 07/23/98 Ru-103 -4.34E+00 5.79E+00 2.22E+01 TF 06 43149 07/23/98 Ru-106 -2.09E+01 6.93E+01 2.62E+02 TF 06 43149 07/23/98 Sb-124 2.40E+01 1.96E+01 6.39E+01 TF 06 43149 07/23/98 Se-75 1.15E+01 7.77E+00 2.46E+01 TF 06 43149 07/23/98 Th-232 -1.99E+01 2.86E+01 1.09E+02 TF 06 43149 07/23/98 Zn-65 2.76E+01 1.72E+01 5.46E+01 TF 06 43149 07/23/98 Zr-95 -3.97E+00 1.15E+01 4.24E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i 1
p.
-Seaorook Nuclear Power Station Raciological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC ,
TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TF 06 43685 08/20/98 Ag-110M -1.68E+01 1.27E+01 5.66E+01 TF 06 43685 08/20/98 Ba-140 1.09E+01 1.21E+01 4.40E+01 TF 06 43685 08/20/98 Be-7 1.33E+02 8.00E+01 2.47E+02 TF 06 43685- 08/20/98 Ce-141 3.05E+00 1.50E+01 4.86E+01 TF 06 43685 08/20/98 Ce-144 -3.03E+01 5.33E+01 1.82E+02 TF 06 43685 08/20/98 Co-57 5.82E+00 6.70E+00 2.09E+01-TF 06 43685 08/20/98 Co-58 -2.06E+01 10.0E+00 4.60E+01 TF 06 43685 08/20/98 Co-60 5.41E+00 9.88E+00 3.84E+01 TF 06 43685 08/20/98 Cr-51 -8.63E+01 8.89E+01 J.43E+02 . TF 06 43685 08/20/98 Cs-134 4.82E+00 1.06E+01 3.66E+01 TF 06 43685 08/20/98 Cs-137 -1.05E+01 1.17E+01 4.94E+01 TF 06 43685 08/20/98 Fe-59 2.97E+01 2.18E+01 6.98E+01 TF 06 43685 08/20/98 I-131 2.93E+01 1.74E+01- 5.41E+01 TF 06 43685 08/20/98 'K-40 1.90E+03 3.52E+02 8.60E+02
- TF 06 43685 08/20/98 Mn-54 -8.89E+00 1.11E+01 4.44E+01 TF 06 43685 08/20/98 Ru-103 3.39E+00 1.12E+01 4.00E+01-TF 06 43685 08/20/98 Ru-106 -8.78E+01 9.82E+01 4.13E+02 TF 06 43685 08/20/98 Sb-124 4.47E+01 2.50E+01 6.67E+01 TF 06 43685 08/20/98 Se-75 -1.04E+01 1.39E+01 5.10E+01 TF 06 43685 08/20/98 Th-232 1~.17E+01 4.3SE+01 1.63E+02 TF 06 43685 08/20/98 Zn-65 -1.22E+01 3.48E+01 1.33E+02 TF 06 43685 08/20/98 Zr-95 9.71E+00 2.05E+01 7.18E+01' l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l
r~ l l I l Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) Milk TM 04 40352 01/14/98 Ag-110M 1.02E+00 1.75E+00 5.99E+00 TM 04 40352 01/14/98 Ba-140 0.59E+00 2.55E+00 9.64E+00 TM 04 40352 01/14/98 Be-7 2.35E+00 1.25E+01 4.34E+01 TM 04 40352 01/14/98 Ce-141 0.00E+00 2.17E+00 6.89E+00 TM 04 40352 01/14/98 Ce-144 -2,34E+00 8.01E+00 2.56E+01 TM 04 40352 01/14/98 Co-57 -0.45E+00 0.97E+00 3.13E+00 TM 04 40352 01/14/98 Co-58 -0.68E+00 1.40E+00 5.21E+00 TM 04 40352 01/14/98 Co-60 2.55E+00 1.82E+00 6.07E+00 TM 04 40352 01/14/98 Cr-51 1.96E+01 1.33E+01 4.23E+01 TM 04 40352 01/14/98 Cs-134 -1.03E+00 1.17E+00 4.36E+00 TM 04 40352 01/14/98 Cs-137 1.92E+00 1.80E+00 6.13E+00 ) TM 04 40352 01/14/98 Fe-59 2.96E+00 4.40E+00 1.56E+01 j TM 04 40352 01/14/98 I-131 -2.37E-02 4.30E-02 0.27E+00 ; TM 04 40352 01/14/98 K-40 1.39E+03 7.40E+01 7.52E+01
- TM 04 40352 01/14/98 Mn-54 1.65E+00 1.39E+00 4.45E+00 TM 04 40352 01/14/98 Ru-103 -1.65E+00 1.65E+00 6.13E+00 TM 04 40352 01/14/98 Ru-106 1.42E+01 1.36E+01 4.66E+01 TM 04 40352 01/14/98 Sb-124 -4.34E+00 3.18E+00 1.50E+01 TM 04 40352 01/14/98 Se-75 3.00E+00 1.84E+00 5.79E+00 TM 04 40352 01/14/98 Th-232 0.96E+00 6.62E+00 2.29E+01 TM 04 40352 01/14/98 Zn-65 -7.43E+00 3.65E+00 1.53E+01 i TM 04 40352 01/14/98 Zr-95 1.06E+00 2.79E+00 9.48E+00 TM 04 40872 02/11/98 Ag-110M 0.21E+00 1.67E+00 5.77E+00 TM 04 40872 02/11/98 Ba-140 2.69E+00 2.01E+00 6.43E+00 TM 04 40872 02/11/98 Be-7 -5.69E+00 1.07E+01 3.81E+01 TM 04 40872 02/11/98 Ce-141 3.85E+00 2.13E+00 6.34E+00 TM 04 ^40872 02/11/98 Ce-144 2.18E+00 7.58E+00 2.35E+01 TM 04 40872 02/11/98 Co-57 1.03E+00 0.99E+00 3.00E+00 TM 04 40872 02/11/98 Co-58 0.30E+00 1.44E+00 4.88E+00 TM 04 40872 02/11/98 Co-60 -0.10E+00 1.24E+00 4.71E+00 TM 04 40872 02/11/98 Cr-51 -0.38E+00 1.19E+01 4.05E+01 TM 04 40872 02/11/98 Cs-134 -0.45E+00 1.21E+00 4.49E+00 TM 04 40872 02/11/98 Cs-137 2.02E+00 1.46E+00 4.86E+00 TM 04 40872 02/11/98 Fe-59 4.77E+00 4.28E+00 1.42E+01 TM 04 40872 02/11/98 I-131 0.18E+00 0.11E+00 0.46E+00 TM 04 40872 02/11/98 K-40 1.49E+03 6.70E+01 7.79E+01
- TM 04 40872 02/1'./98 Mn-54 -1.53E+00 1.20E+00 4.52E+00 TM 04 40872 02/11/98 Ru-103 -2.23E+00 1.42E+00 5.29E+00 TM 04 40872 02/11/98 Ru-106 0.00E+00 1.22E+01 4.43E+01 TM 04 40872 02/11/98 Sb-124 -2.24E+00 2.49E+00 1.07E+01 TM 04 40872 02/11/98 Se-75 1.07E+00 1.60E+00 5.25E+00 TM 04 40872 02/11/98 Th-232 6.09E+00 5.26E+00 1.69E+01 l TM 04 40872 02/11/98 Zn-65 6.59E+00 2.95E+00 8.77E+00 l TM 04 40872 02/11/98 Zr-95 0.00E+00 2.10E+00 7.33E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
L l I
l l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE S?A. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 04 41330 03/11/98 Ag-110M 1.54E+00 1.93E+00 6.31E+00 TM 04 41330 03/11/98 Ba-140 -1.07E+00 1.80E+00 7.19E+00 TM 04 41330 03/11/98 Be-7 1.94E+00 1.03E+01 3.59E+01 TM 04 41330 03/11/98 Ce-141 0.82E+00 2.30E+00 7.16E+00 TM 04 41330 03/11/98 Ce-144 -7.90E+00 8.90E+00 2.89E+01 TM 04 41330 03/11/98 Co-57 0.23E+00 1.20E+00 3.74E+00 TM 04 41330 03/11/98 Co-58 -1.98E+00 1.20E+00 4.74E+00 TM 04 41330 03/11/98 Co-60 3.46E-02 1.47E+00 5.40E+00 TM 04 41330 03/11/98 Cr-51 2.83E+00 1.21E+01 4.11E+01 TM 04 41330 03/11/98 Cs-134 0.62E+00 1.23E+00 4.05E+00 TM 04 41330 03/11/98 Cs-137 3.41E+00 1.69E+00 5.39E+00 TM 04 41330 03/11/98 Fe-59 -3.47E+00 3.41E+00 1.39E+01 TM 04 41330 03/11/98 I-131 -3.31E-02 2.41E-02 0.22E+00 TM 04 41330 03/11/98 K-40 1.33E+03 6.36E+01 7.40E+01
- TM 04 41330 03/11/98 Mn-54 -1.07E+00 1.21E+00 4.51E+00 TM 04 41330 03/11/98 Ru-103 -1.85E+00 1.32E+00 5.02E+00 TM 04 41330 03/11/98 Ru-106 2.03E+01 1.12E+01 3.61E+01 TM 04 41330 03/11/98 Sb-124 0.15E+00 2.93E+00 1.10E+01 TM 04 41330 03/11/98 Se-75 -0.11E+00 1.79E+00 6.06E+00 TM 04 41330 03/11/98 Th-232 4.03E+00 4.70E+00 1.57E+01 TM 04 41330 03/11/98 Zn-65 -1.24E+00 7.09E+00 2.73E+01 TM 04 41330 03/11/98 Zr-95 1.66E+00 2.30E+00 7.58E+00 TM 04 41602 04/08/98 Ag-110M 2.98E+00 1.80E+00 5.49E+00 TM 04 41602 04/08/98 Ba-140 2.05E+00 1.71E+00 5.65E+00 i TM 04 41602 04/08/98 Be-7 7.19E+00 1.03E+01 3.44E+01 TM 04 41602 04/08/98 Ce-141 -0.59E+00 2.05E+00 6.57E+00 l TM 04 41602 04/08/98 Ce-144 5.86E+00 7.36E+00 2.25E+01 TM 04 41602 04/08/98 Co-57 0.46E+00 0.93E+00 2.88E+00 TM 04 41602 04/08/98 Co-58 -0.45E+00 1.33E+00 4.78E+00 TM 04 41602 04/08/98 Co-60 -1.25E+00 1.59E+00 6.46E+00 TM 04 41602 04/08/98 Cr-51 3.27E+00 1.28E+01 4.31E+01 TM 04 41602 04/08/98 Cs-134 -1.05E+00 1.19E+00 4.31E+00 TM 04 41602 04/08/98 Cs-137 -1.65E+00 1.49E+00 5.81E+00 TM 04 41602 04/08/98 Fe-59 -3.61E+00 3.29E+00 1.39E+01 TM 04 41602 04/08/90 I-131 -6.08E-02 4.58E-02 0.43E+00 TM 04 41602 04/08/98 K-40 1.41E+03 7.02E+01 8.43E+01
- TM 04 41602 04/08/98 Mn-54 -0.27E+00 1.16E+00 4.20E+00 TM 04 41602 04/08/98 Ru-103 -0.39E+00 1.17E+00 4.26E+00 TM 04 41602 04/08/98 Ru-106 -5.19E+00 1.33E+01 4.95E+01 TM 04 41602 04/08/98 Sb-124 3.58E+00 3.09E+00 1.05E+01 TM 04 41602 04/08/98 Se-75 -0.50E+00 1.58E+00 5.43E+00 TM 04 41602 04/08/98 Th-232 -8.63E+00 4.91E+00 1.96E+01 TM 04 41602 04/08/98 Zn-65 1.22E+00 3.63E+00 1.27E+01 TM 04 41602 04/08/98 Zr-95 0.29E+00 2.49E+00 8.56E+00 l
l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC ! TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) {
)
TM 04 41901 04/22/98 Ag-110M 1.60E+00 1.46E+00 4.69E+00 TM 04 41901 04/22/98 Ba-140- 2.55E+00 1.88E+00 6.02E+00 TM 04 41901 04/22/98 Be-7 6.35E+00 9.83E+00 3.30E+01 TM 04 41901 04/22/98 Ce-141 0.42E+00 1.93E+00 6.06E+00 TM 04 41901 04/22/98 Ce-144 -1.51E+00 7.13E+00 2.27E+01 TM 04 41901 04/22/98 Co-57 -9.76E-02 0.95E+00 3.00E+00 TM 04 41901 04/22/98 Co-58 -2.12E+00 1.14E+00 4.46E+00 TM 04 41901 04/22/98 Co-60 0.60E+00 1.12E+00 3.99E+00 TM 04 41901 04/22/98 Cr-51 4.56E+00 1.15E+01 3.87E+01 TM 04 41901 04/22/98 Cs-134 -0.14E+00 1.10E+00 3.82E+00 TM 04 41901 04/22/98 Cs-137 0.83E+00 1.28E+00 4.47E+00 TM 04 41901 04/22/98 Fe-59 -0.86E+00 3.60E+00 1.34E+01 TM 04 41901 04/22/98 I-131 -4.15E-02 2.61E-02 0.19E+00 TM 04 41901 04/22/98 K-40 1.30E+03 5.72E+01 6.38E+01
- TM 04 41901 04/22/98 Mn-54 -0.34E+00 1.00E+00 3.61E+00 TM 04 41901 04/22/98 Ru-103 0.78E+00 1.13E+00 3.81E+00 TM 04 41901 04/22/98 Ru-106 -7.07E+00 1.10E+01 4.16E+01 TM 04 41901 04/22/98 Sb-124 0.63E+00 2.48E+00 9.16E+00 TM 04 41901 04/22/98 Se-75 1.17E+00 1.58E+00 5.16E+00 TM 04 41901 04/22/98 Th-232 2.70E+00 4.45E+00 1.50E+01 TM 04 41901 04/22/98 Zn-65 2.89E+00 2.81E+00 9.35E+00 TM 04 41901 04/22/98 Zr-95 0.32E+00 2.10E+00 7.17E+00 TM 04 42152 05/06/98 Ag-110M 0.81E+00 1.45E+00 4.78E+00 TM 04 42152 05/06/98 Ba-140 2.95E+00 1.90E+00 5.91E+00 TM 04 42152 05/06/98 Be-7 1.57E+01 9.80E+00 3.08E+01 TM 04 42152 05/06/98 Ce-141 -4.41E+00 1.87E+00 6.29E+00 TM 04 42152 05/06/98 Ce-144 3.84E+00 6.42E+00 1.96E+01 TM 04 42152 05/06/98 Co-57 1.04E+00 0.85E+00 2.56E+00 TM 04 42152 05/06/98 Co-58 2.98E+00 1.22E+00 3.52E+00 TM 04 42152 05/06/98 Co-60 -0.56E+00 1.21E+00 4.50E+00 TM 04 42152 05/06/98 Cr-51 -5.53E+00 1.06E+01 3.65E+01 TM 04 42152 05/06/98 Cs-134 -2.73E-02 0.92E+00 3.12E+00 TM 04 42152 05/06/98 Cs-137 3.57E+00 1.29E+00 3.95E+00 TM 04 42152 05/06/98 Fe-59 0.76E+00 3.72E+00 1.31E+01 TM 04 42152 05/06/98 I-131 -1.29E-02 5.55E-02 0.42E+00 TM 04 42152 05/06/98 K-40 1.38E+03 5.58E+01 7.60E+01
- TM 04 42152 05/06/98 Mn-54 0.49E+00 0.91E+00 3.04E+00 TM 04 42152 05/06/98 Ru-103 -2.18E-02 1.18E+00 4.05E+00 TM 04 42152 05/06/98 Ru-106 -9.00E+00 9.41E+00 3.57E+01 TM 04 42152 05/06/98 Sb-124 -0.45E+00 2.19E+00 8.50E+00 TM 04 42152 05/06/98 Se-75 0.60E+00 1.38E+00 4.53E+00 TM 04 42152 05/06/98 Th-232 -1.17E+00 3.96E+00 1.39E+01 TM 04 42152 05/06/98 Zn-65 1.39E+00 3.02E+00 9.79E+00 l TM 04 42152 05/06/98 Zr-95 2.11E+00 2.31E+00 7.37E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I k
c: 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE. STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 04 42277 05/20/98 Ag-110M -1.50E+00 2.78E+00 1.08E+01 TM 04 42277 05/20/98 Ba-140 -3.90E+00 2.76E+00 1.36E+01 TM 04 42277 05/20/98 Be-7 -1,37E+01 1.60E+01 6.25E+01 TM 04 42277 05/20/98 Ce-141 0.73E+00 3.26E+00 1.05E+01 TM 04 42277 05/20/98 Ce-144 1.17E+00 1.13E+01 3.63E+01 TM 04 42277 05/20/98 Co-57 1.60E+00 1.41E+00 4.30E+00 TM 04 42277 05/20/98 Co-58 0.60E+00 2.33E+00- 8.19E+00 TM '04 42277 05/20/98 Co-60 5.52E+00 2.62E+00 7.69E+00 TM 04 42277 05/20/98 Cr-51 6.81E+00 1.85E+01 6.37E+01 TM 04 42277 05/20/98 Cs-134 2.68E+00 2.00E+00 6.26E+00 TM 04 42277 05/20/98 .Cs-137 1.31E+00 2.59E+00 9.34E+00 TM 04 42277 05/20/98 Fe-59 -1.06E+01 5.63E+00 2.70E+01 24 04 42277 05/20/98 I-131 5.21E-02 5.47E-02 0.25E+00 TM - 04 42277 05/20/98 K-40 1.29E+03 9.86E+01 1.27E+02'* TM 04 42277 05/20/98 Mn-54 2.07E+00 1.61E+00 5.16E+00 TM 04 42277 05/20/98 Ru-103 0.51E+00 2.16E+00 7.68E+00 TM 04 42277 05/20/98 Ru-106 2.23E+01 1.37E+01 4.38E+01 TM 04 42277 05/20/98 Sb-124 5.76E+00 5.25E+00 1.82E+01 TM 04 42277 05/20/98 Se-75 -1.84E+00 2.45E+00 8.89E+00 TM 04 42277 05/20/98 Th-232 -5.68E+00 7.24E+00 2.94E+01 1M 04 42277 05/20/98 Zn-65 -1.17E+01 6.05E+00 2.56E+01 TM- 04 42277 05/20/98 Zr-95 -0.25E+00 3.28E+00 1.23E+01 TM .04- 42584 06/03/98 Ag-110M 0.13E+00 2.22E+00 8.15E+00 TM - 04 42584 06/03/98 Ba-140 1.13E+00 3.22E+00 1.24E+01 TM 04 42584 06/03/98- Be-7 1.71E+01 1.63E+01 5.37E+01 TM. 04 42584 06/03/98- Ce-141 0.81E+00 3.20E+00 1.00E+01 TM 04 42584 06/03/98 Ce-144 -1.17E+01 1.02E+01 3.39E+01 TM 04 .42584 06/03/98 Co-57 0.42E+00 1.37E+00 4.30E+00 TM 04 42584 06/03/98 Co-58 3.68E+00 2.04E+00 6.08E+00 m 2Pf - 04 42584 -06/03/98 -Co-60 -1.57E+00 2.29E+00 9.51E+00 TM 04 42584 06/03/98 Cr-51 4.92E+01 2.05E+01 6.10E+01 TM 04 42584 06/03/98 Cs-134 -0.78E+00 1.56E+00 5.72E+00
._ TM~ 04 42584 06/03/98 Cs-137 4.85E+00 2.19E+00 6.74E+00 TM 04 42584 06/03/98 -Fe-59 3.80E+00 7.08E+00 2.51E+01 TM 04 42584 06/03/98 I-131 9.95E-03 7.70E-02 0.45E&OO TM 04 42584 06/03/98 K-40 1.31E+03 8.74E+01 1.04E+02
- TM 04 42584 06/03/98 Mn-54 1.10E+00 1.35E+00 4.61E+00 TM 04 42584 06/03/98 Ru-103 -3.25E+00 2.03E+00 8.03E+00-TM 04 42584 06/03/98 Ru-106 -3.22E+01 1.46E+01 6.57E+01 TM 04 42584 06/03/98 Sb-124 -0.90E+00 3.77E+00 1.67E+01 TM 04 42584 06/03/98 Se-75 -1.07E+00 2.37E+00 8.32E+00 TM 04 42584 06/03/98. .Th-232 -3.11E+00 8.27E+00 3.02E+01 TM - 04 - 42584 06/03/98 Zn-65 1.12E+01 1.16E+01 4.38E+01 TM 04 42584 06/03/98 Zr-95 3.77E+00 2.96E+00 9.42E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
f
r Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 04 42688 06/17/98 Ag-110M -3.42E+00 3.16E+00 1.31E+01 TM 04 42688 06/17/98 Ba-140 1.84E+00 2.72E+00 1.05E+01 TM 04 42688 06/17/98 Be-7 2.46E+00 1.85E+01 6.72E+01 TM 04 42688 06/17/98 Ce-141 -1.74E+00 3.10E+00 1.05E+01 TM 04 42688 06/17/98 Ce-144 5.16E+00 1.30E+01 4.13E+01 TM 04 42688 06/17/98 Co-57 -3.20E+00 1.54E+00 5.54E+00 TM 04 42688 06/17/98 Co-58 2.17E+00 2.47E+00 8.28E+00 TM 04 42688 06/17/98 Co-60 -0.80E+00 2.79E+00 1.14E+01 TH 04 42688 06/17/98 Cr-51 -3.86E+01 1.97E+01 7.92E+01 TM 04 42688 06/17/98 Cs-134 0.27E+00 1.72E+00 6.04E+00 TM 04 42688 06/17/98 Cs-137 1.59E+00 2.75E+00 9.97E+00 TM 04 42688 06/17/98 Fe-59 -3.58E+00 7.84E+00 3.19E+01 TM 04 42688 06/17/98 I-131 -4.48E-02 6.16E-02 0.53E+00 TM 04 42688 06/17/98 K-40 1.52E+03 1.15E+02 1.33E+02
- TM 04 42688 06/17/98 Mn-54 -3.75E+00 2.19E+00 9.48E+00 TM 04 42688 06/17/98 Ru-103 2.16E+00 2.07E+00 6.94E+00 TM 04 42688 06/17/98 Ru-106 0.00E+00 2.26E+01 8.65E+01 TM 04 42688 06/17/98 Sb-124 0.00E+00 5.84E+00 2.40E+01 TM 04 42688 06/17/98 Se-75 -4.99E+00 2.67E+00 1.04E+01 TM 04 42688 06/17/98 Th-232 1.06E+00 7.43E+00 2.85E+01 TM 04 42688 06/17/98 Zn-65 2.44E+00 6.92E+00 2.50E+01 TM 04 42688 06/17/98 Zr-95 2.98E+00 3.85E+00 1.40E+01 TM 04 42914 07/01/98 Ag-110M -1. 3 4 E+ 0 0 1.71E+00 6.69E+00 TM 04 42914 07/01/98 Ba-140 3.93E+00 1.95E+00 4.86E+00 TM 04 42914 07/01/98 Be-7 4.98E+00 1.17E+01 4.08E+01 TM 04 42914 07/01/98 Ce-141 -0.51E+00 2.65E+00 R.64E+00 TM 04 42914 07/01/98 Ce-144 1.00E+01 9.22E+00 2.81E+01 TM 04 42914 07/01/98 Co-57 -0.64E+00 1.16E+00 3.82E+00 TM 04 42914 07/01/98 Co-58 -1.08E+00 1.56E+00 5.81E+00 TM 04 42914 07/01/98 Co-60 2.90E+00 1.71E+00 5.33E+00 TM 04 42914 07/01/98 Cr-51 2.31E+01 1.46E+01 4.61E+01 :
TM 04 42914 07/01/98 Cs-134 -0.75E+00 1.18E+00 4.37E+00 l TM 04 42914 07/01/98 Cs-137 2.31E+00 1.76E+00 5.91E+00 TM 04 42914 07/01/98 Fe-59 8.25E-02 4.06E+00 1.56E+01 TM 04 42914 07/01/98 I-131 -4.90E-02 2.59E-02 0.24E+00 TM 04 42914 07/01/98 K-40 1.26E+03 7.03E+01 8.33E+01
- TM 04 42914 07/01/98 Mn-54 4.10E+00 1.54E+00 4.17E+00 TM 04 42914 07/01/98 Ru-103 1.36E+00 1.60E+00 5.37E+00 TM 04 42914 07/01/98 Ru-106 -2.19E+00 1.14E+01 4.41E+01 TM 04 42914 07/01/98 Sb-124 -0.20E+00 2.35E+00 1.01E+01 TM 04 42914 07/01/98 Se-75 0.18E+00 1.83E+00 6.27E+00 TM 04 42914 07/01/98 Th-232 5.42E+00 4.71E+00 1.55E+01 TM 04 42914 07/01/98 Zn-65 -0.51E+00 3.39E+00 1.20E+01 TM 04 42914 07/01/98 Zr-95 1.00E+00 2.84E+00 1.04E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 04 43150 07/22/98 Ag-110M 0.60E+00 1.69E+00 5.73E+00 TM 04 43150 07/22/98 Ba-140 2.21E+00 1.95E+00 6.41E+00 TM 04 43150 07/22/98 Be-7 4.97E+00' 1.01E+01 3.41E+01 L TM 04 43150 07/22/98 Ce-141 -0.17E+00 1.78E+00 5.59E+00 TM 04 43150 07/22/98 Ce-144 -9.65E+00 6.67E+00 2.19E+01 TM 04 43150 07/22/98 Co-57 0.16E+00 0.83E+00 2.60E+00 TM 04 43150 07/22/98 Co-58 -0.96E+00 1.17E+00 4.32E+00 TM 04 43150 07/22/98 Co-60 -1.85E+00 1.85E+00 7.24E+00 TM 04 43150 07/22/98 Cr-51 -2.80E+00 1.10E+01 3.78E+01 TM 04 43150 07/22/98 Cs-134 1.00E+00 1.22E+00 4.21E+00 TM 04 43150 07/22/98 Cs-137 5.26E+00 1.40E+00 3.98E+00 *
.TM 04 43150 07/22/98 Fe-59 2.21E+00 3.78E+00 1.32E+01 4.60E-02 5.27E-02 TM 04 43150 07/22/98 I-131 0.24E+00 TM 04 43150 07/22/98 K-40 1.34E+03 6.26E+01 6.97E+01
- TM 04 43150 07/22/98 Mn-54 -0.64E+00 1.18E+00 4.24E+00 TM 04 43150 07/22/98 Ru-103 -2.24E+00 1.23E+00 4.69E+00
.TM 04 43150 07/22/98 Ru-106 -8.82E+00 9.97E+00 3.89E+01 TM 04 43150 07/22/98 Sb-124 -6.94E+00- 2.74E+00 1.33E+01 TM 04 43150 07/22/98 Se-75 2.11E-02 1.54E+00 5.18E+00 TM 04 43150 07/22/98 Th-232 3.14E+00 5.07E+00 1.70E+01 TM 04 43150 07/22/98 Zn-65 1.21E+00 3.27E+00 1.14E+01 TM 04 43150 07/22/98 Zr-95 -0.33E+00 2.37E+00 8.17E+00 TM 04- 43389 08/05/98 Ag-110M 2.59E+00 3.34E+00 1.12E+01 ]
TM - 04 43389 08/05/98 Ba-140 -1.57E+00 2.44E+00 1.17E+01 '
~ TM 04 43389 08/05/98 Be-7 3.16E+00 1.69E+01 6.05E+01 TM 04 43389 08/05/98 Ce-141 2.87E+00 2.95E+00 9.08E+00 TM 04 43389 08/05/98 Ce-144 -1.57E+01 1.10E+01 3.81E+01 TM 04 43389 08/05/98 Co-57 1.47E+00 1.51E+00 4.64E+00 TM 04 43389 08/05/98 Co-58 2.36E+00 2.18E+00 7.09E+00 TM 04 43380 08/05/98 Co-60 3.60E+00 2.00E+00 5.81E+00 1.38E+01 )
- l. TM 04 43389 08/05/98 Cr-51 1.76E+01 5.92E+01 Cs-134 -1.53E+00 1.54E+00 TM 04 43389 08/05/98 5.94E+00 TM 04 43389 08/05/98 Cs-137 3.18E+00 2.44E+00 8.23E+00 TM 04 43389 08/05/98 Fe-59 -3.94E+00 7.98E+00 3.15E+01 TM 04 43389 08/05/98 I-131 3.75E-02 6.68E-02 0.34E+00 t- TM 04 43389 08/05/98 K-40 1.36E403 1.04E+02 1.49E+02
- l TM 04 43389 08/05/98 Mn-54 0.00E+00 1.54E+00 5.98E+00
- l. TM 04 43389 08/05/98 Ru-103 -0.93E+00 2.09E+00 7.89E+00 1 TM 04 43389 08/05/98 Ru-106 8.03E+00 1.78E+01 6.59E+01 l TM 04 43389 08/05/98 Sb-124 1.86E+00 4.00E+00 1.60E+01 TM 04 43389 08/05/98 Se-75 -2.22E+00 2.29E+00 8.54E+00 TM ~ 04 43389 08/05/98 Th-232 -3.17E+00 8.36E+00 3.19E+01 TM 04 43389 08/05/98 Zn-65 1.79E+00 5.49E+00 2.01E+01 TM 04 43389 08/05/98 Zr-95 0.00E+00 2.69E+00 1.12E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)'
l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 04 43686 08/19/98 Ag-110M 0.78E+00 1.77E+00 6.20E+00 1 TM 04 43686 08/19/98 Ba-140 1.76E+00 2.02E+00 7.00E+00 i TM 04 43686 08/19/98 Be-7 -1.31E+01 1.13E+01 4.17E+01 l TM 04 43686 08/19/98 Ce-141 0.98E+00 2.25E+00 6.97E+00 TM 04 43686 08/19/98 Ce-144 5.27E+00 8.61E+00 2.65E+01 TM 04 43686 08/19/98 Co-57 -0.70E+00 1.13E+00 3.64E+00 TM 04 43686 08/19/98 Co-58 -0.57E+00 1.24E+00 4.47E+00 TM 04 43686 08/19/98 Co-60 0.48E+00 1.25E+00 4.44E+00 TM 04 43686 08/19/98 Cr-51 1.03E+01 1.22E+01 4.01E+01 TM 04 43686 08/19/98 Cs-134 -0.36E+00 1.06E+00 3.75E+00 TM 04 43686 08/19/98 Cs-137 5.44E+00 1.55E+00 4.02E+00
- TM 04 43686 08/19/98 Fe-59 -3.04E+00 4.54E+00 1.66E+01 TM 04 43686 08/19/98 I-131 8.59E-03 3.57E-02 0.21E+00 TM 04 43686 08/19/98 K-40 1.25E+03 6.11E+01 8.16E+01
- TM 04 43686 08/19/98 Mn-54 0.39E+00 1.14E+00 3.91E+00 TM 04 43686 08/19/98 Ru-103 -5.94E-02 1.28E+00 4.51E+00 TM 04 43686 08/19/98 Ru-106 8.02E+00 1.10E+01 3.87E+01 TM 04 43686 08/19/98 Sb-124 1.34E+00 2.94E+00 1.08E+01 TM 04 43686 08/19/98 Se-75 -1.67E+00 1.62E+00 5.76E+00 TM 04 43686 08/19/98 Th-232 8.25E+00 5.36E+00 1.71E+01 TM 04 43686 08/19/98 Zn-65 0.30E+00 3.31E+00 1.17E+01 TM 04 43686 08/19/98 Zr-95 -1.53E+00 1.83E+00 6.99E+00 TM 04 43974 09/02/98 Ag-110M 0.15E+00 1.61E+00 5.66E+00 TM 04 43974 09/02/98 Ba-140 -3.44E+00 1.44E+00 7.69E+00 TM 04 43974 09/02/98 Be-7 5.12E+00 1.01E+01 3.45E+01 TM 04 43974 09/02/98 Ce-141 -1,35E+00 2.16E+00 7.05E+00 TM 04 43974 09/02/98 Ce-144 5.01E+00 8.33E+00 2.58E+01 TM 04 43974 09/02/98 Co-57 0.56E+00 1.09E+00 3.36E+00 TM 04 43974 09/02/98 Co-58 -0.72E+00 1.45E+00 5.20E+00 TM 04 43974 09/02/98 Co-60 0.31E+00 1.11E+00 4.14E+00 TM 04 43974 09/02/98 Cr-51 -3.42E+01 1.37E+01 5.21E+01 TM 04 43974 09/02/98 Cs-134 0.33E+00 1.31E+00 4.68E+00 TM 04 43974 09/02/98 Cs-137 8.02E+00 2.21E+00 6.56E+00
- TM 04 43974 09/02/98 Fe-59 4.83E+00 3.74E+00 1.23E+01 TM 04 43974 09/02/98 I-131 3.472-02 5.16E-02 0.26E+00 TM 04 43974 09/02/98 K-40 1.34E+03 6.37E+01 7.25E+01
- TM 04 43974 09/02/98 Mn-54 -0.46E+00 1.19E+00 4.29E+00 TM 04 43974 09/02/98 Ru-103 -2.48E+00 1.32E+00 5.21E+00 TM 04 43974 09/02/98 Ru-106 -3.41E+00 1.13E+01 4.27E+01 TM 04 43974 09/02/98 Sb-124 -1.38E+00 2.87E+00 1.15E+01 TM 04 43974 09/02/98 Se-75 -2.77E-02 1.65E+00 5.63E+00 TM 04 43974 09/02/98 Th-232 6.14E+00 4.68E+00 1.51E+01 TM 04 43974 09/02/98 Zn-65 -0.81E+00 2.53E+00 9.65E+00 l TM 04 43974 09/02/98 Zr-95 9.66E-02 2.22E+00 7.79E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i
l 1 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 04 44362 09/23/98 Ag-110M -0.59E+00 1.74E+00 6.23E+00 TM 04 44362 09/23/98 Ba-140 1.04E+00 2.01E+00 7.11E+00 TM 04 44362 09/23/98 Be-7 -2.54E+01 8.90E+00 3.79E+01 TM 04 44362 09/23/98 Ce-141 1.86E+00 2.09E+00 6.41E+00 TM 04 44362 09/23/98 Ce-144 2.94E+00 7.80E+00 2.44E+01 l TM 04 44362 09/23/98 Co-57 0.12E+00 1.02E+00 3.23E+00 TM 04 44362 09/23/98 Co-58 -2.59E+00 1.18E+00 4.85E+00 TM 04 44362 09/23/98 Co-60 -0.93E+00 1.17E+00 4.82E+00 { TM 04 44362 09/23/98 Cr-51 7.37E+00 1.22E+01 4.07E+01 l TM 04 44362 09/23/98 Cs-134 0.50E+00 1.21E+00 3.98E+00 4 TM 04 44362 09/23/98 Cs-137 1.80E+00 1.40E+00 4.71E+00 l TM 04 44362 09/23/98 Fe-59 5.69E+00 4.12E+00 1.34E+01 l TM 04 44362 09/23/98 I-131 0.17E+00 0.12E+00 0.50E+00 TM 04 44362 09/23/98 K-40 1.29E+03 6.18E+01 6.26E+01
- TM 04 44362 09/23/98 Mn-54 -0.36E+00 1.04E+00 3.82E+00 TM 04 44362 09/23/98 Ru-103 -3.71E+00 1.23E+00 5.17E+00 TM 04 44362 09/23/98 Ru-106 -1.70E+00 9.45E+00 3.62E+01 TM 04 44362 09/23/98 Sb-124 2.17E+00 2.75E+00 9.58E+00 TM 04 44362 09/23/98 Se-75 -1.74E+00 1.72E+00 6.10E+00 TM 04 44362 09/23/98 Th-232 1.53E+00 4.41E+00 1.54E+01 TM 04 44362 09/23/98 Zn-65 2.74E+00 2.82E+00 9.51E+00 TM 04 44362 09/23/98 Zr-95 2.11E+00 2.40E+00 7.82E+00 TM 04 45107 10/14/98 Ag-110M -1.17E+00 1.80E+00 6.56E+00 TM 04 45107 10/14/98 Ba-140 -2.48E+00 1.85E+00 7.94E+00 TM 04 45107 10/14/98 Be-7 1.58E+01 9.18E+00 2.85E+01 TM 04 45107 10/14/98 Ce-141 0.99E+00 1.95E+00 6.00E+00 TM 04 45107 10/14/98 Ce-144 2.02E+00 7.40E+00 2.29E+01 TM 04 45107 10/14/98 Co-57 -0.27E+00 0.87E+00 2.77E+00 TM 04 45107 10/14/98 Co-58 -0.42E+00 1.33E+00 4.72E+00 TM 04 45107 10/14/98 Co-60 -2.04E+00 1.72E+00 6.99E+00 TM 04 45107 10/14/98 Cr-51 7.02E+00 1.19E+01 3.92E+01 TM 04 45107 10/14/98 Cs-134 1.73E+00 1.20E+00 3.71E+00 i TM 04 45107 10/14/98 Cs-137 1.15E+00 1.56E+00 5.42E+00 j TM 04 45107 10/14/98 Fe-59 -8.45E+00 4.47E+00 1.83E+01 )
TM 04 45107 10/14/98 I-131 0.28E+00 0.12E+00 0.38E+00 ! TM 04 45107 10/14/98 K-40 1.40E+03 6.74E+01 7.79E+01
- TM 04 45107 10/14/98 Mn-54 -1.26E+00 1.27E+00 4.70E+00 TM 04 45107 10/14/98 Ru-103 -0.97E+00 1.28E+00 4.67E+00 i TM 04 45107 10/14/98 Ru-106 3.22E+00 1.21E+01 4.33E+01 i TM 04 45107 10/14/98 Sb-124 -1.58E+00 2.87E+00 1.20E+01 i TM 04 45107 10/14/98 Se-75 -2.51E+00 1.61E+00 5.76E+00 l' TM 04 45107 10/14/98 Th-232 1.92E+00 4.86E+00 1.68E+01 TM 04 45107 10/14/98 Zn-65 -1.83E+00 3.23E+00 1.21E+01 TM 04 45107 10/14/98 Zr-95 -0.36E+00 2.16E+00 7.63E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
t I 1
E' Seabrook Wuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE' CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 04 45704 11/18/98 Ag-110M 1.31E+00 2.04E+00 6.90E+00
'TM 04 45704 11/18/98 Ba-140 -3.11E+00 1.89E+00 9.35E+00 TM 04 45704 11/18/98 Be-7 5.32E+00 1.29E+01 4.43E+01 TM 04 45704 11/18/98 Ce-141 -1.47E+00 2.34E+00 7.64E+00 'fM 04 45704 11/18/98 Ce-144 -4.70E+00 8.95E+00 2.88E+01 TM 04 45704 11/18/98 Co-57 0.54E+00 1.21E+00 3.73E+00 TM 04 45704 11/18/98 Co-58 1.10E+00 1.57E+00 5.26E+00 TM 04 45704 11/18/98 Co-60 2.90E+00 1.95E+00 6.24E+00 TM 04 45704 11/18/98 Cr-511 0.00E+00 1.39E+01 4.78E+01 TM 04 45704 11/18/98 Cs-134 -0.30E+00 1.19E+00 4.09E+00 TM 04 45704 11/18/98 Cs-137 0.26E+00 1.82E+00 6.62E+00 TM 04 45704 11/18/98 Fe-59 9.40E+00 6.20E+00 1.98E+01 TM 04 45704 11/18/98 I-131 -3.71E-02' 4.93E-02 0.42E+00 TM 04 45704 11/18/98 K-40 1.52E+03 8.18E+01 9.15E+01
- TM 04 45704 11/18/98 Mn-54 -1.46E+00 1.39E+00 5.41E+00 TM 04 45704 11/18/98 Ru-103 -1.15E+00 1.55E+00 5.76E+00 TM 04 45704 11/18/98 Ru-106 1.34E+01 1.?7E+01 4.74E+01 TM 04 45704 11/18/98 Sb-124 -3.98E+00 4.09E+00 1.72E+01 TM 04 45704 11/18/98 Se-75 -2.83E+00 1.96E+00 7.10E+00 TM 04 45704 11/18/98 Th-232 1.32E+00 6.41E+00 2.24E+01 TM 04 45704 11/18/98 Zn-65 -4.11E+00 4.14E+00 1.61E+01 TM 04 45704 11/18/98 Zr-95 2.94E+00 2.95E+00 1.02E+01 n
?
TM 04 46231 12/16/98 Ag-110M -3.51E+00 1.42E+00 5.67E+00 TM 04 46231 12/16/98 Ba-140 -3.70E+00 1.79E+00 7.59E+00 TM 04 46231 12/16/98 Be-7 9.90E+00 8.57E+00 2.77E+01 TM 04 46231 12/16/98 Ce-141 1.39E+00 1.62E+00 4.91E+00 Ti', 04 46231 12/16/98 Ce-144 3.80E+00 6.20E+00 1.89E+01 TM 04 46231 12/16/98 Co-57 -0.44E+00 0.78E+00 2.45E+00 TM 04 46231 12/16/98 Co-58 1.07E+00 1.09E+00 3.50E+00 ) TM 04 46231 12/16/98 Co-60 -1.53E+00 1.53E+00 5.96E+00 TM 04 46231 12/16/98 Cr-51 -6.15E+00 9.75E+00 3.37E+01 TM 04 46231 12/16/98 Cs-134 -0.44E+00 0.99E+00 3.42E+00 TM 04 46231 12/16/98 Cs-137 2.45E+00 1.25E+00 4.00E+00 TM 04 46231 12/16/98 Fe-59 -1.12E+00 3.42E+00 1.27E+01 g TM 04 46231 12/16/98 I-131 -9.45E-02 4.24E-02 0.43E+00 TM 04 46231 12/16/98 K-40 1.39E+03 5.71E+01 5.26E+01
- TM 04 46231 12/16/98 Mn-54 1.78E+00 1.10E+00 3.35E+00 TM 04 46231 12/16/98 Ru-103 -0.51E+00 1.06E+00 3.75E+00 TM 04 46231 12/16/98 Ru-106 -1.21E+01 1.01E+01 3.88E+01 TM 04 46231 12/16/98 Sb-124 1.25E+00 2.72E+00 9.87E+00 TM 04 46231 12/16/98 Se-75 -0.97E+00 1.36E+00 4.65E+00 TM 04 46231 12/16/98 Th-232 -3.45E+00 4.43E+00 1.60E+01 TM 04 46231 12/16/98 Zn-65 0.52E+00 2.91E+00 1.02E+01 TM 04 46231 12/16/98 Zr-95 3.53E+00 1.91E+00 5.74E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
1 [ d
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program
. Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
________________________________________________________________________________ i TM 08 40353 01/14/98 Ag-110M 0.44E+00 1.49E+00 5.19E+00 13( 08 40353 01/14/98 Ba-140 2.08E+00 2.24E+00 7.59E+00 TM 08 40353 01/14/98 Be-7 -9.69E+00 1.03E+01 3.88E+01 TM 08 40353 01/14/98 Ce-141 1.21E+00 2.07E+00 6.45E+00 , TM 08 40353 01/14/98 Ce-144 9.80E+00 7.65E+00 2.31E+01 i TM 08 40353 01/14/98 Co-57 -0.71E+00 0.93E+00 3.09E+00 TM 08 40353 01/14/98 Co-SS 0.17E+00 1.13E+00 3.98E+00 TM 08 40353 01/14/98 Co-60 -0.35E+00 1.29E+00 4.97E+00 TM 08 40353 01/14/98 Cr-51 1.67E+00 1.25E+01 4.28E+01 TM 08 40353 01/14/98 Cs-134 -1.49E+00 1.28E+00 4.95E+00 j TM .08 40353 01/14/98 Cs-137 4.21E+00 1.80E+00 6.56E+00 ! TM 08 40353 01/14/98 Fe-59 3.21E+00 3.43E+00 1.18E+01 TM 08 40353 01/14/98 I-131 -5.41E-02 3.06E-02 0.29E+00 TM 08 40353 01/14/98 K-40 1.12E+03 5.86E+01 6.94E+01
- TM 08 40353 01/14/98 Mn-54 -1.95E+00 1.02E+00 4.21E+00 TM 08 40353 01/14/98 Ru-103 -3.51E+00 1.19E+00 5.06E+00 TM 08 40353 01/14/98 Ru-106 -1.88E+01 1.12E+01 4.59E+01 TM 08 40353 01/14/98 Sb-124 -2.59E+00 2.17E+00 1.01E+01 TM 08 40353 01/14/98 Se-75 0.97E+00 1.54E+00 5.12E+00 TM 08 40353 01/14/98 Th-232 6.71E+00 4.42E+00 1.40E+01 l TM 08 40353 01/14/98 Zn-65 -2.05E+00 2.89E+00 1.11E+01 TM 08 40353 01/14/98 Zr-95 -0.77E+00 2.09E+00 7.63E+00 TM 08 40873 02/11/98 Ag-110M -2.11E+00 1.90E+00 7.38E+00 TM 08 40873 02/11/98 Ba-140 1.25E+00 1.89E+00 6.87E+00 TM 08 40873 02/11/98 Be-7 -1.69E+00 1.13E+01 4.05E+01 TM 08 40873 02/11/98 Ce-141 1.89E+00 2.18E+00 6.66E+00 TM 08 40873 02/11/98 Ce-144 0.21E+00 8.30E+00 2.61E+01 TM 08 40873 02/11/98 Co-57 1.24E+00 1.05E+00 3.18E+00 TM 08 40873 02/11/98 Co-58 2.45E+00 1.61E+00 4.96E+00 !
TM 08 40873 02/11/98 Co-60 1.46E+00 1.92E+00 6.85E+00 k TM 08 40873 02/11/98 Cr 51 7.02E+00 1.27E+01 4.25E+01 i TM 08 40873 02/11/98 Cs-134 2.36E+00 1.39E+00 4.51E+00 TM 08 40873 02/11/98 Cs-137 5.53E+00 2.88E+00 9.78E+00 TM 08 40873 02/11/98 Fe-59 4.47E+00 4.95E+00 1.69E+01 TM 08 40873 02/11/98 I-131 3.87E-02 6.92E-02 0.36E+00 TM 08 40873 02/11/98 K-40 1.71E+03 8.14E+01 7.25E+01
- TM 08 40873 02/11/98 Mn-54 -0.38E+00 1.44E+00 5.17E+00 TM 08 40873 02/11/98 Ru-103 -1.85E+00 1.50E+00 5.67E+00 TM 08 40873 02/11/98 Ru-106 -2.02E+00 1.44E+01 5.33E+01 TM 08 40873 02/11/98 -Sb-124 5.49E+00 3.74E+00 1.20E+01 TM 08 40873 02/11/98 Se-75 -1.22E+00 1.76E+00 6.18E+00 TM 08 40873 02/11/98 Th-232 0.31E+00 6.16E+00 2.17E+01 TM 08 40873 02/11/98 Zn-65 -6.81E+00 4.25E+00 1.68E+01 TM 08 40873 02/11/98 Zr-95 1.82E+00 2.71E+00 9.00E+00 l
]
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.) 4 1
4 4
Seabrook Nuclear Power Station Radiological-Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE 'STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 08 41331 03/11/98 Ag-110M -1.14E+00 1.98E+00 7.31E+00 TM 08 41331 03/11/98 Ba-140 3.35E+00 1.99E+00 6.25E+00 TM 08 -41331 03/11/98 Be-7 -1.96E+01 1.11E+01 4.23E+01 TM 08 41331 03/11/98 Ce-141 -4.99E+00 2.41E+00 8.20E+00 TH 08 41331 03/11/98 Ce-144 1.10E+00 9.62E+00 3.00E+01 TM 08 41331 03/11/98 Co-57 -8.42E-02 1.21E+00 3.79E+00 TM 08 41331 03/11/98' Co-58 1.76E+00 1.35E+00 4.24E+00 TM - 08 41331 03/11/98 Co-60 0.91E+00 1.41E+00 4.82E+00 TM 08 41331 03/11/98 Cr-51 7.85E+00 1.43E+01 4.73E+01 TM 08 41331 03/11/98 Cs-134 -3.69E+00 3.68E+00 1.36E+01 TM 08 41331 03/11/98 Cs-137 3.41E+00 1.58E+00 4.99E+00 TM 08 41331 03/11/98 Fe-59 -5.35E+00 4.17E+00 1.61E+01 TM 08. 41331 03/11/98 I-131 3.99E-02 4.71E-02 0.22E+00 i TM. 08 41331 03/11/98 K-40 1.31E+03 6.25E+01 7.55E+01
- TM 08 41331 03/11/98 Mn-54 1.53E+00 1.22E+00 3.84E+00 TM 08 41331 03/11/98 Ru-103 -3.10E+00 1.39E+00 5.44E+00 TM 08 41331 03/11/98 Ru-106 1.48E+01 1.26E+01 4.27E+01 TM 08 41331 03/11/98 Sb-124 0.14E+00 3.20E+00 1.21E+01 .
TM 08 41331 03/11/98 Se-75 0.95E+00 1.90E+00 6.26E+00 ' TM 08 41331 03/11/98 Th-232 -2.69E+00 5.18E+00 1.92E+01 TM 08 41331 03/11/98 .Zn-65 -1.67E+00 6.88E+00 2.61E+01 TM 08 41331 03/11/98 Zr-95 1.07E+00 2.16E+00 7.26E+00 TM ~ 08 41603 04/08/98 Ag-110M -0.78E+00 1.87E+00 6.90E+00 TM 08 41603 04/08/98 Ba-140 1.56E+00 2.38E+00 8.36E+00 TM 08 41603 04/08/98 Be-7 1.84E+01 1.16E+01 3.63E+01 TM 08 41603 04/08/98 Ce-141 2.31E+00 2.18E+00 6.59E+00 TM 08 41603 04/08/98 Ce-144 2.09E+01 7.99E+00 2.27E+01 TM 08 41603 04/08/98 Co-57 -1.37E+00 1.05E+00 3.46E+00 TM 08 41603 04/08/98 Co-58 0.66E+00 1.35E+00 4.61E+00 TM 08 41603 04/08/98 Co-60 0.00E+00 1.78E+00 6.84E+00 TM 08 41603 04/08/98 Cr-51 -2.06E+01 1.21E+01 4.55E+01 TM 08 41603 04/08/98 Cs-134 1.18E+00 1.36E+00 4.18E+00 TM 08 41603 04/08/98 Cs-137 4.57E+00 2.05E+00 6.46E+00 TM 08 41603 04/08/98 Fe-59 -1.15E+01 4.37E+00 1.98E+01 TM 08 41603 04/08/98 I-131 5.06E-02 6.87E-02 0.35E+00 TM 08 41603 04/08/98 K-40 1.56E+03 7.90E+01 8.75E+01
- TM 08 41603 04/08/98 Mn-54 -1.83E+00 1.57E+00 5.88E+00 TM 08 41603 04/08/98 Ru-103 -0.35E+00 1.45E+00 5.18E+00 TM 08 41603 04/08/98 Ru-106 1.21E+01 1.45E+01 5.04E+01 TM 08 41603 04/08/98 Sb-124 0.40E+00 3.81E+00 1.47E+01 TM 08 41603 04/08/98 Se-75 1.64E+00 1.70E+00 5.52E+00 TM 08 41603 04/08/98 Th-232 -4.31E+00 6.03E+00 2.24E+01 TM 08 41603 04/08/98 Zn-65 -5.29E+00 3.96E+00 1.56E+01 TM 08 41603 04/08/98 Zr-95 -5.63E+00 2.34E+00 9.84E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC / TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) 4 ____________________________________________..__________________________________ TM 08 41902 04/22/98 Ag-110M -0.92E+00 1.67E+00 6.16E+00 TM 08 41902 04/22/98 Ba-140 -0.56E+00 1.86E+00 7.33E+00 TM 08 41902 04/22/98 Be-7 -9.80E+00 9.90E+00 3.62E+01 TM 08 41902 04/22/98 Ce-141 -2.36E+00 2.30E+00 7.56E+00 TM 08 41902 04/22/98 Ce-144 1.53E+01 7.62E+00 2.22E+01 TM 08 41902 04/22/98 Co-57 0.30E+C0 1.00E+00 3.11E+00 TM 08 41902 04/22/98 Co-58 0.13E+00 1.14E+00 3.92E+00 TM 08 41902 04/22/98 Co-60 -0.44E+00 1.41E+00 5.09E+00 TM 08 41902 04/22/98 Cr-51 -1.67E+01 1.20E+01 4.33E+01 TM 08 41902 04/22/98 Cs-134 -0.60E+00 0.99E+00 3.50E+00 TM 08 41902 04/22/98 Cs-137 0.32E+00 1.15E+00 4.15E+00 TM 08 41902 04/22/98 Fe-59 -0.60E+00 4.21E+00 1.48E+01 TM 08 41902 04/22/98 I-131 -2.27E-02 1.89E-02 0.16E+00 TM 08 41902 04/22/98 K-40 1.76E+03 6.38E+01 5.40E+01
- TM 08 41902 04/22/98 Mn-54 0.65E+00 1.17E+00 3.87E+00 TM 08 41902 04/22/98 Ru-103 -1.48E+00 1.32E+00 4.85E+00 TM 08 41902 04/22/98 Ru-106 0.00E+00 1.17E+01 4.22E+01 TM 08 41902 04/22/98 Sb-124 1.12E+00 2.06E+00 7.69E+00 TM 08 41902 04/22/98 Se-75 0.24E+00 1.57E+00 5.24E+00 TM 08 41902 04/22/98 Th-232 3.97E+00 4.83E+00 1.63E+01 TM 08 (1902 04/22/98 Zn-65 0.84E+00 2.97E+00 1.03E+01 TM 08 41907 04/22/98 Zr-95 -1.08E+00 2.09E+00 7.44E+00 TM 08 42153 05/06/98 Ag-110M 1.92E+00 1.88E+00 6.04E+00 TM 08 42153 05/06/98 Ba-140 1.46E+00 2.82E+00 1.00E+01 TM 08 42153 05/06/98 Be-7 -7.92E+00 1.23E+01 4.38E+01 TM 08 42153 05/06/98 Ce-141 0.51E+00 2.24E+00 7.02E+00 TM 08 42153 05/06/98 Ce-144 -1.58E+01 7.51E+00 2.50E+01 TM 08 42153 05/06/98 Co-57 -0.72E+00 0.98E+00 3.14E+00 TM 08 42153 05/06/98 Co-58 -1.11E+00 1.35E+00 4.98E+00 TM 08 42153 05/06/98 Co-60 -0.83E+00 1.78E+00 6.66E+00 TM 08 42153 05/06/98 Cr-51 -0.22E+00 1.43E+01 4.84E+01 TM 08 42153 05/06/98 Cs-134 -1.04E+00 1.12E+00 4.16E+00 TM 08 42153 05/06/98 Cs-137 0.38E+00 1.66E+00 5.91E+00 TM 08 42153 05/06/98 Fe-59 1.42E+00 5.00E+00 1.77E+01 TM 08 42153 05/06/98 I-131 1.22E-02 6.74E-02 0.41E+00 TM 08 42153 05/06/98 K-40 1.70E+03 7.35E+01 8.30E+01
- TM 08 42153 05/06/98 Mn-54 1.52E+00 1.53E+00 4.91E+00 TM 08 42153 05/06/98 Ru-103 0.16E+00 1.48E+00 5.13E+00 TM 08 42153 05/06/98 Ru-106 -1.28E+01 1.14E+01 4.48E+01 TM 08 42153 05/06/98 Sh-124 4.11E+00 3.16E+00 1.02E+01 TM 08 42153 05/06/98 Se-75 2.17E+00 1.77E+00 5.64E+00 TM 08 42153 05/06/98 Th-232- -0.19E+00 5.77E+00 2.00E+01 TM 08 42153 05/06/98 in-65 0.26E+00 3.94E+00 1.38E+01 TM 08 42153 05/06/98 Zr-95 -0.77E+00 2.92E+00 1.08E+01 l
I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i _ _ _ _ _ _ _ _ _ _ _ _ _ -
p Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 08 42278 05/20/98. Ag-110M O.85E+00 3.13E+00 1.12E+01 TM 08 42278 05/20/98 Ba-140 0.24E+00 3.52E+00 1.40E+01 TM 08 42278 05/20/98 9e-7 1.39E+01 1.64E+01 5.58E+01 TM 08 42278 05/20/98 Ce-141 0.22E+00 3.07E+00 9.90E+00 TM 08 42278 05/20/98 Ce-144 1.26E+00 1.16E+01 3.74E+01 TM 08 42278 05/20/38 Co-57 -0.26E+00 1.55E+00 5.01E+00 TM 08 42278 05/20/98 Co-58 0.53E+00 2.46E+00 - 8.76E+00 TM 08 42278 05/20/98 Co-60 1.09E+00 2.77E+00 1.06E+01 TM 08 42278 05/20/98 Cr-51 -1.32E+01 1.68E+01 6.37E+01 TM 08 42278 05/20/98 Cs-134 -0.69E+00 1.99E+00 7.33E+00 TM 08 42278 05/20/98 Cs-137 1.07E+00 2.53E+00 9.29E+00 TM 08 42278 05/20/98 'e-59 -0.70E+00 8.49E+00 3.22E+01 TM 08 42278 05/20/98 *
-131 -2.17E-02 2.37E-02 0.20E+00 TM 08 42278 05/20/98 K-40 1.86E+03 1.20E+02 1.06E+02
- TM 08 42278 05/20/98 Mn-54 -4.15E+00 2.06E+00 9.02E+00 TM 08 42278 05/20/98 Ru-103 -0.28E+00 1.91E+00 7.22E+00 TM 08 42278 05/20/98 Ru-106 1.21E+01 1.93E+01 7.01E+01 TM 08 42278 05/20/98 Sb-124 -0.99E+00 5.60E+00 2.38E+01 TM 08 42278 05/20/98 Se-75 -5.98E+00 2.51E+00 1.00E+01 TM 08 42278 05/20/98 Th-232 -4.79E+00 7.82E+00 3.14E+01 TM 08 42278 05/20/98 Zn-65 -9.63E+00 6.13E+00 2.58E+01 TM 08 42278 05/20/98 Zr-95 7.88E+00 4.33E+00 1.29E+01 TM 08 42585 06/03/98 Ag-110M -3.47E+00 2.07E+00 8.37E+00 TM 08 42585 06/03/98 Ba-140 -0.69E+00 3.21E+00 1.20E+01 TM 08 42595 06/03/98 Be-7 -2.63E+00 1.27E+01 4.57E+01 TM 08 42585 06/03/98 Ce-141 0.28E+00 2.72E+00 8.59E+00 TM 08 42585 06/03/98 Ce-144 -7.36E+00 1.00E+01 3.22E+01 TM 08 42585 06/03/98 Co-57 -2.58E+00 1.16E+00 3.94E+00 TM 08 42585 06/03/98 Co-58 -1.83E+00 1.69E+00 6.45E+00 TM 08 42585 06/03/98 Co-60 2.41E+00 1.75E+00 5.70E+00 TM 08 42585 06/03/98 Cr-51 -1.36E+01 1.66E+01 5.91E+01 TM 08 42585 06/03/98 Cs-134 -1.27E+00 1.40E+00 5.27E+00 TM 08 42585 06/03/98 Cs-137 5.56E+00 2.91E+00 1.08E+01 TM 08 42585 06/03/98 Fe-59 -6.51E+00 5.20E+00 2.16E+01 TM <0 8 42585 06/03/98 I-131 0.18E+00 0.12E+00 0.47E+00 TM 08 42585 06/03/98 K-40 1.87E+03 9.03E+01 9.26E+01
- TM 08 42585 06/03/98 Mn-54 -0.77E+00 1.67E+00 6.03E+00 TM 08 42585 06/03/98 Ru-103 -1.65E+00 1.85E+00 6.82E+00 TM 08 42585 06/03/98 Ru-106 -4.48E+00 1.52E+01 5.71E+01 TM 08 42585 06/03/98 Sb-124 3.46E+00 3.69E+00 1.27E+01 TM 08 42585 06/03/98 Se-75 -3.68E+00 2.14E+00 7.75E+00 TM 08 42585 06/03/98 Th-232 8.18E+00 6.29E+00 2.02E+01 TM 08 42585 06/03/98 Zn-65 9.53E+00 4.81E+00 1.48E+01 TM 08 42585 06/03/98 Zr-95 -4.20E+00 2.97E+00 1.23E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
r. Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 08 42689 06/18/98 Ag-110M -1.38E+00 2.13E+00 8.24E+00 TM 08 42689 06/18/98 Ba-140 -1.54E+00 2.19E+00 9.26E+00 TM 08 42689 06/18/98 Be-7 -1.41E+01 1.04E+01 4.18E+01 TM 08 42689 06/18/98 Ce-141 -1.51E+00 2.80E+00 9.22E+00 TM 08 42689 06/18/98 Ce-144 1.92E+01 1.06E+01 3.11E+01 TM 08 42689 06/18/98 Co-57 -3.90E-02 1.31E+00 4.17E+00 TM 08 42689 06/18/98 Co-58 -4.16E+00 1.43E+00 6.27E+00 TM 08 42689 06/18/98 Co-60 1.86E+00 1.91E+00 6.35E+00 TM 08 42689 06/18/98 Cr-51 -2.38E+01 1.51E+01 5.63E+01 1 TM 08 42689 06/18/98 Cs-134 -1.56E+00 1.37E+00 5.58E+00 l TM 08 42689 06/18/98 Cs-137 4.05E+00 1.96E+00 6.20E+00 TM 08 42689 06/18/98 Fe-59 1.14E+00 4.68E+00 1.67E+01 TM 08 42689 06/18/98 I-131 -5.58E-03 5.09E-02 0.31E+00 TM 08 42689 06/18/98 K-40 1.74E+03 8.24E+01 7.34E+01
- TM 08 42689 06/18/98 Mn-54 -0.21E+00 1.42E+00 5.12E+00 I TM 08 42689 06/18/98 Ru-103 -1.02E+00 1.67E+00 6.15E+00 TM 08 42689 06/18/98 Ru-106 0.00E+00 1.29E+01 4.86E+01 TM 08 42689 06/18/98 Sb-124 -7.02E+00 2.48E+00 1.42E+01 TM 08 42689 06/18/98 Se-75 0.51E+00 1.95E+00 6.62E+00 TM 08 42689 06/18/98 Th-232 1.53E+01 6.95E+00 2.10E+01 TM 08 42689 06/18/98 Zn-65 -2.07E+00 3.89E+00 1.47E+01 J TM 08 42689 06/18/98 Zr-95 0.37E+00 2.25E+00 8.06E+00 j TM 08 42915 07/01/98 Ag-110M 1.62E+00 2.22E+00 7.40E+00 TM 08 42915 07/01/98 Ba-140 0.80E+00 3.45E+00 1.28E+01 TM 08 42915 07/01/98 Be-7 2.36E+00 1.41C+01 4.90E+01 TM 08 42915 07/01/98 Ce-141 0.47E+00 2.88E+00 9.18E+00 TM 08 42915 07/01/98 Ce-144 2.38E+00 9.49E+00 2.98E+01 TM 08 42915 07/01/98 Co-57 -0.37E+00 1.1.E+00 3.69E+00 TM 08 42915 07/01/98 Co-58 0.00E+00 1.71E+00 6.03E+00 TM 08 42915 07/01/98 Co-60 -1.32E+00 1.66E+00 6.79E+00 TM 08 42915 07/01/98 Cr-51 1.41E+01 1.64E+01 5.40E+01 TM 08 42915 07/01/98 Cs-134 -0.22E+00 1.67E+00 5.86E+00 TM 08 42915 07/01/98 Cs-137 3.97E+00 1.65E+00 4.98E+00 TM 08 42915 07/01/98 Fe-59 1.91E+00 5.44E+00 1.96E+01 TM 08 42915 07/01/98 I-131 5.72E-03 6.79E-02 0.40E+00 TM 08 42915 07/01/98 K-40 1.81E+03 8.99E+01 1.19E+02
- TM 08 42915 07/01/98 Mn-54 -0.14E+00 1.61E+00 5.71E+00 TM 08 42915 07/01/98 Ru-103 0.22E+00 1.75E+00 6.14E+00 TM- 08 42915 07/01/98 Ru-106 3.12E+01 1.46E+01 4.54E+01 TM 08 42915 07/01/98 Sb-124 -0.22E+00 2.65E+00 1.14E+01 TM 08 42915 07/01/98 Se-75 ' -1.17E+00 2.04E+00 7.14E+00 TM 08 42915 07/01/98 Th-232 2.35E+00 5.45E+00 1.91E+01 TM 08 42915 07/01/98 Zn-65 2.08E+00 3.59E+00 1 20E+01 TM 08 42915 07/01/98 Zr-95 2.63E+00 2.69E+00 8.78E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Fower Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 08 43151 07/22/98 Ag-110M -0.59E+00 1.94E+00 6.73E+00 TM 08 43151 07/22/98 Ba-140 2.36E+00 1.99E+00 6.49E+00 TM 08 43151 07/22/98 Be-7 -1.01E+00 9.74E+00 3.40E+01 TM 08 43151 07/22/98 Ce-141 -2.65E+00 1.85E+00 6.03E+00 TM 08 43151 07/22/98 Ce-144 -2.58E+00 7.09E+00 2.23E+01 TM- 08 43151 07/22/98 Co-57 0.36E+00 0.95E+00 2.91E+00 TM 08 43151 07/22/98 Co-58 -2.75E+00 1.36E+00 5.20E+00 TM 08 43151 07/22/98 Co-60 -2.09E+00 1.78E+00 7.04E+00 TM 08 43151 07/22/98 Cr-51 9.28E+00 1.13E+01 3.67E+01 TM 08 43151 07/22/98 Cs-134 0.35E+00 1.17E+00 3.87E+00 TM 08 43151 07/22/98 Cs-137 0.35E+00 1.41E+00 5.02E+00 TM 08 43151 07/22/98 Fe-59 -7.81E+00 4.55E+00 1.80E+01 TM 08 43151 07/22/98 I-131 1.78E-02 3.99E-02 0.21E+00 TM 08 43151 07/22/98 K-40 1.83E+03 7.18E+01 6.69E+01
- TM 08 43151 07/22/98 Mn-54 -1.27E+00 1.29E+00 4.69E+00 TM 08 43151 07/22/98 Ru-103 -2.84E+00 1.24E+00 4.82E400 TM 08 43151 07/22/98 Ru-106 -2.90E+00 1.18E+01 4.33E+01 TM 08 43151 07/22/98 Sb-124 4.00E+00 2.84E+00 9.25E+00 TM 08 43151 07/22/98 Se-75 -0.33E+00 1.56E+00 5.26E+00 TM 08 43151 07/22/98 Th-232 -8.11E+00 5.26E+00 1.98E+01 TM 08 43151 07/22/98 Zn-65 3.87E+00 3.74E+00 1.24E+01 TM 08 43151 07/22/98 Zr-95 -2.12E+00 2.39E+00 8.58E+00 TM 08 43390 08/05/98 Ag-110M -1.04E+00 1.74E+00 6.29E+00 TM 08 43390 08/05/98 Ba-140 -0.S4E+00 1.54E+00 6.22E+00 TM 08 43390 08/05/98 Be-7 -2.82E+00 9.33E+00 3.34E+01 TM 08 43390 08/05/98 Ce-141 1.44E+00 1.92E+00 5.87E+00 TM 08 43390 08/05/98 Ce-144 4.35E+00 7.64E+00 2.35E+01 TM -08 43390 08/05/98 Co-57 -0.18E+00 0.97E+00 3.07E+00 TM 08 43390 08/05/98 Co-58 -1.95E+00 1.33E+00 5.01E+00 TM 08 43390 08/05/98 Co-60 0.37E+00 1.54E+00 5.54E+00 TM 08 43390 08/05/98 Cr-51 1.68E+01 1.26E+01 4.01E+01 TM 08 43390 08/05/98 Cs-134 0.90E+00 1.10E+00 3.56E+00 TM 08 43390 08/05/98 Cs-137 0.56E+00 1.44E+00 5.10E+00 TM 08 43390 08/05/98 Fe-59 3.48E+00 4.63E+00 1.58E+01 TM 08 43390 08/05/98 I-131 -6.17E-03 6.33E-02 0.47E+00 TM 08 43390 08/05/98 K-40 1.91E+03 7.58E+01 8.79E+01
- i TM 08 43390 08/05/98 Mn-54 0.38E+00 1.19E+00 4.04E+00 TM 08 43390 08/05/98 Ru-103 0.71E+00 1.29E+00 4.35E+00 TM 08 43390 08/05/98 Ru-106 1.85E+01 1.14E+01 3.71E+01 TM 08 43390 08/05/98 Sb-124 0.73E+00 2.10E+00 8.07E+00 TM 08 43390 08/05/98 Se-75 2.12E+00 1.62E+00 5.18E+00 TM 08 43390 08/05/98 Th-232 3.80E+00 5.02E+00 1.67E+01 TM 08 43390 08/05/98 Zn-65 0.77E+00 3.74E+00 1.30E+01 TM 08 43390 08/05/98 Zr-95 1.38E+00 2.13E+00 6.12E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
)
TM 08 43687 08/19/98 Ag-110M 0.71E+00 2.28E+00 7.83E+00 TM 08 43687 08/19/98 Ba-140 0.22E+00 1.52E+00 6.39E+00 TM 08 43687 08/19/98 Be-7 5.87E+00 1.19E+01 4.10E+01 TM 08 43687 08/19/98 Ce-141 1.94E+00 2.48E+00 7.60E+00 TM 08 43687 08/19/98 Ce-144 -3.99E+00 9.41E+00 3.00E+01 TM 08 43687 08/19/98 Co-57 0.59E+00 1.18E+00 3.65E+00 I TM 08 43687 08/19/98 Co-58 -0.73E+00 1.64E+00 5.97E+00 TM 08 43687 08/19/98 Co-60 -0.15E+00 1.83E+00 6.96E+00 l TM 08 43687 08/19/98 Cr-51 1.84E+00 1.38E+01 4.72E+01 TM 08 43687 08/19/98 Cs-134 1.68E+00 1.26E+00 3.79E+00 TM 08 43687 08/19/98 Cs-137 0.00E+00 1.98E+00 7.23E+00 TM 08 43687 08/19/98 Fe-59 -5.92E+00 5.02E+00 2.06E+01 TM 08 43687 08/19/98 I-131 -9.28E-03 3.21E-02 0.18E+00 TM 08 43687 08/19/98 K-40 1.86E+03 9.25E+01 1.23E+02
- l TM 08 43687 08/19/98 Mn-54 1.04E+00 1.49E+00 4.98E+00 i TM 08 43687 08/19/98 Ru-103 -0.27E+00 1.69E+00 5.98E+00 1 TM 08 43687 08/19/98 Ru-106 -4.44E+00 1.57E+01 5.87E+01 I TM 08 43687 08/19/98 Sb-124 1.31E+00 3.43E+00 1.29E+01 TM 08 43687 08/19/98 Se-75 -2.72E+00 1.83E+00 6.67E+00 TM 08 43687 08/19/98 Th-232 -1.29E+01 5.38E+00 2.31E+01 TM 08 43687 08/19/98 Zn-65 2.09E+00 4.39E+00 1.44E+01 TM 08 43687 08/19/98 Zr-95 -3.49E+00 3.63E+00 1.41E+01 TM 08 43975 09/02/98 Ag-110M 2.15E+00 2.10E+00 6.96E+00 TM 08 43975 09/02/98 Ba-140 -3.15E+00 1.92E+00 8.85E+00 TM 08 43975 09/02/98 Be-7 -1.34E+01 1.11E+01 4.15E+01 TM 08 43975 09/02/98 Ce-141 5.06E+00 2.49E+00 7.26E+00 TM 08 43975 09/02/98 Ce-144 6.86E+00 8.52E+00 2.61E+01 TM 08 43975 09/02/98 Co-57 -2.21E+00 1.13E+00 3.80E+00 TM 08 43975 09/02/98 Co-58 -2.21E+00 1.29E+00 5.03E+00 TM 08 43975 09/02/98 Co-60 1.35E+00 1.67E+00 5.57E+00 TM 08 43975 09/02/98 Cr-51 1.52E+01 1.28E+01 4.12E+01 TM 08 43975 09/02/98 Cs-134 0.32E+00 1.09E+00 3.95E+00 TM 08 43975 09/02/98 Cs-137 1.36E+00 1.47E+00 5.05E+00 TM 08 13975 09/02/98 Fe-59 8.18E+00 5.09E+00 1.58E+01 TM 08 43975 09/02/98 I-131 -7.65E-02 3.22E-02 0.32E+00 TM 08 43975 09/02/98 K-40 1.86E'03 7.31E+01 7.41E+01
- TM 08 43975 09/02/98 Mn-54 0.40E+00 1.32E+00 4.47E+00 TM 08 43975 09/02/98 Ru-103 -1.55E+00 1.28E+00 4.87E+00 TM 08 43975 09/02/98 Ru-106 -3.31E+00 1.17E+01 4.37E+01 TM 08 43975 09/02/98 Sb-124 1.92E+00 2.64E+00 9.55E+00 TM 08 43975 09/02/98 Se-75 -1.03E+00 1.70E+00 5.92E+00 TM 08 43975 09/02/98 Th-232 3.01E+00 5.78E+00 1.98E+01 TM 08 43975 09/02/98 Zn-65 1.20E+00 3.35E+00 1.17E+01 TM 08 43975 09/02/98 Zr-95 -2.15E+00 2.13E+00 8.04E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 08 44363 09/23/98 Ag-110M 2.74E+00 2.15E+00 7.01E+00 l TM 08 44363 09/23/98 Ba-140 -1.18E+00 2.09E+00 8.31E+00 TM 08 44363 09/23/98 Be-7 -1.19E+01 9.47E+00 3.63E+01 TM 08 44363 09/23/98 Ce-141 -5.38E+00 2.33E+00 8.04E+00 TM 08 44363 09/23/98 Ce-144 -2.64E+00 8.32E+00 2.66E+01 TM 08 44363 09/23/98 Co-57 -1.24E+00 1.11E+00 3.63E+00 TM 08 44363 09/23/98 Co-58 -1.41E+00 1.35E+00 5.00E+00 TM 08 44363 09/23/98 Co-60 2.51E+00 1.71E+00 5.39E+00 TM 08 44363 09/23/98 Cr-51 9.34E+00 1.36E+01 4.49E+01 TM 08 44363 09/23/98 Cs-134 3.21E+00 1.56E+00 4.10E+00 TM 08 44363 09/23/98 Cs-137 0.19E+00 1.47E+00 5.31E+00 TM 08 44363 09/23/98 Fe-59 8.08E+00 4.66E+00 1.43E+01 TM 08 44363 09/23/98 I-131 6.72E-02 8.73E-02 0.43E+00 TM 08 44363 09/23/98 K-40 1.80E+03 7.22E+01 7.58E+01
- TM 08 44363 09/23/98 Mn-54 4.94E-02 1.31E+00 4.50E+00 TM 08 44363 09/23/98 Ru-103 0.78E+00 1.32E+00 4.51E+00 TM 08 44363 09/23/98 Ru-106 1.15E+01 1.29E+01 4.42E+01 TM 08 44363 09/23/98 Sb-124 -3.84E+00 3.33E+00 1.38E+01 TM 08 44363 09/23/98 Se-75 0.35E+00 1.77E+00 5.92E+00 4 TM 08 44363 09/23/98 Th-232 9.70E+00 5.07E+00 1.57E+01 I TM 08 44363 09/23/?8 Zn-65 -1.92E+00 3.51E+00 1.29E+01 TM 08 44363 09/23/98 Zr-95 3.24E+00 2.25E+00 7.00E+00 l
TM 08 45108 10/14/98 Ag-110M -8.05E-02 2.05E+00 7.12E+00 l TM 08 45108 10/14/98 Ba-140 0.62E+00 2.38E+00 8.60E+00 3 TM 08 45108 10/14/98 Be-7 -1.67E+01 1.04E+01 4.01E+01 l TM 08 45108 10/14/98 Ce-141 0.69E+00 2.14E+00 6.70E+00 TM 08 45108 10/14/98 Ce-144 1.39E+Cl 7.89E+00 2.32E+01 TM 08 45108 10/14/98 Co-57 0.38E+0u 1.02E+00 3.16E+00 TM 08 45108 10/14/98 Co-58 0.99E+0D 1.51E+00 4.98E+00 TM 08 45108 10/14/98 Co-60 1.80E+00 1.66E+00 5.57E+00 l I TM 08 45108 10/14/98 Cr-51 1.21E+01 1.24E+01 4.03E+01 TM 08 45108 10/14/98 Cs-134 0.46E+00 1.17E+00 4.01E+00 TM 08 45108 10/14/98 Cs-137 4.45E+00 1.54E+00 4.52E+00 j TM 08 45108 10/14/98 Fe-59 2.76E+00 4.81E+00 1.67E+01 , TM 08 45108 10/14/98 I-131 0.11E+00 8.41E-02 0.34E+00 ' TM 08 45108 10/14/98 K-40 1.88E+03 8.19E+01 9.57E+01
- TM 08 45108 10/14/98 Mn-54 0.55E+00 1.34E+00 4.55E+00 .
TM 08 45108 10/14/98 Ru-103 -1.45E+00 1.41E+00 5.21S+00 } TM 08 45108 10/14/98 Ru-106 8.87E+00 1.32E+01 4 . 61'E+ 01 TM 08 45108 10/14/98 Sb-124 1.91E+00 2.86E+00 1.03E+01 TM 08 45108 10/14/98 Se-75 -1.89E+00 1.73E+00 6.08E+00 TM 08 45108 10/14/98 Th-232 -3.38E+00 6.28E+00 2.24E+01 TM 08 45108 10/14/98 Zn-65 0.39E+00 4.15E+00 1.46E+01 TM 08 45108 10/14/98 Zr-95 -3.58E+00 2.72E+00 1.09E+01 i
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program ) Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 08 45705 11/18/98 Ag-110M 0.23E+00 1.58E+00 5.36E+00 TM 08 45705 11/18/98 Ba-140 -2.34E+00 1.28E+00 5.89E+00 TM 08 45705 11/18/98 Be-7 -7.75E+00 8.70E+00 3.19E+01 TM 08 45705 11/18/98 Ce-141 3.26E+00 1.90E+00 5.66E+00 TM 08 45705 11/18/98 Ce-144 -7.69E+00 6.90E+00 2.26E+01 TM 08 45705 11/18/98 Co-57 -0.67E+00 0.95E+00 3.05E+00 TM 08 45705 11/18/98 Co-58 -0.62E+00 1.18E+00 4.17E+00 TN 08 45705 11/1E/98 Co-60 1.20E+00 1.35E+00 4.57E+00 TM- 08 45705 11/1P/98 Cr-51 -2.92E+00 1.12E+01 3.83E+01 TM 08 45705 11/18/98 Cs-134 -4.66E+00 2.35E+00 8.64E+00 TM 08 45705 11/18/98 Cs-137 1.23E+00 1.23E+00 4.21E+00 TM 08 45705 11/18/98 Fe-59 -2.02E+00 3.56E+00 1.33E+01 TM 08 45705 11/18/98 I-131 7.47E-03 8.39E-02 0.48E+00 1M 08 45705 11/18/98 K-40 1.96E+03 6.68E+01 6.41E+01
- TM 08 45705 11/18/98 Mn-54 -1.65E+00 1.11E+00 4.15E+00 TM 08 45705 11/18/98 Ru-103 -2,16E+00 1.23E+00 4.63E+00 TM 08- 45705 11/18/98 Ru-106 -2.61E+00 1.04E+01 3.84E+01 TM 08 45705 11/18/98 Sb-124 2.86E+00 2.00E+00 6.31E+00 TM 08 45705 11/18/98 Se-75 -0.29E+00 1.44E+00 4.90E+00 TM 08 45705 11/18/98 Th-232 0.74E+00 4.23E+00 1.46E+01 TM 08 45705 11/18/98 Zn-65 -4.08E+00 3.13E+00 1.17E+01 TM 08 45705 11/18/98 Zr-95 0.86E+00 2.32E+00 8.24E+00 TM' 08 4t232 12/16/98 Ag-110M 0.81E+00 1.02E+00 3.29E+00 TM 08 46232 12/16/98 Ba-140 0.64E+00 1.12E+00 3.82E+00 TM 08 46232 12/16/98 Be-7 -4.75E+00 6.89E+00 2.39E+01 TM 08 46232 12/16/98 Ce-141 3.62E+00 1.49E+00 4.32E+00 TM 08 46232 12/16/98 Ce-144 1.25E+00 5.55E+00 1.70E+01 TM 08 46232 12/16/98 Co-57 0.33E+00 0.73E+00 2.21E+00 TM 08 46232 12/16/98 Co-58 1.23E+00 0.83E+00 2.58E+00 TM 08 46232 12/16/98 Co-60 1.388+00 0.92E+00 2.94E+00 TM 08 46232 12/16/98 Cr-51 -1.62E+01 8.34E+00 2.93E+01 TM 08 46232 12/16/98 Cs-134 0.83E+00 2.37E+00 8.65E+00 TM 08 46232 12/16/98 Cs-137 0.26E+00 0.95E+00 3.33E+00 TM 08 46232 12/16/98 Fe-59 0.15E+00 2.58E+00 8.98E+00 l TM 08 46232 12/16/98 I-131 6.54E-02 7.40E-02 0.35E+00 TM 08 46232 12/16/98 K-40 1.28E+03 4.08E+01 4.58E+01
- TM 08 46232 12/16/98 Mn-54 -1.34E+00 0.88E+00 3.10E+00 TM 08 46232 12/16/98 Ru-103 -2.58E-02 0.87E+00 2.93E+00 TM 08 46232 12/16/98 Ru-106 -3.60E+00 6.79E+00 2.49E+01 TM 08 46232 12/16/98 Sb-124 -2.54E+00 1.36E+00 5.87E+00 TM- 08 46232 12/16/98 Se-75 -0.91E+00 1.19E+00 3.99E+00 TM 08 46232 12/16/98 Th-232 0.49E+00 3.25E+00 1.09E+01 TM 08 46232 12/16/98 Zn-65 -1.96E+00 4.66E+00 1.77E+01 TM 08 46232 12/16/98 Zr-95 -2.28E+00 1.38E+00 5.01E+00 I
- Radioactivity detected in nample (i.e., CONC > 3 STD. DEV.)
I l l I i l Seabrook Nuclear Power Station i Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 09 40354 01/14/98 Ag-110M -1.75E+00 1.76E+00 6.90E+00 TM 09 40354 01/14/98 Ba-140 1.48E+00 2.24E+00 8.16E+00 TM 09 40354 01/14/98 Be-7 3.52E+00 1.10E+01 3.82E+01 TM- 09 40354 01/14/98 Ce-141 -0.80E+00 2.21E+00 7.10E+00 TM 09 40354 01/14/98 Ce-144 -2.98E+00 8.48E+00 2.70E+01 TM 09 40354 01/14/98 Co-57 -0.42E+00 1.05E+00 3.35E+00 TM 09 40354 01/14/98 Co-58 -2.19E+00 1.60E+00 6.14E+00 TM 09 40354 01/14/98 Co-60 0.00E+00 2.12E+00 7.97E+00 l TM 09 40354 01/14/98 Cr-51 0.00E+00 1.43E+01 4.90E+01 TM 09 40354 01/14/98 Cs-134 2.07E+00 1.46E+00 4.54E+00 TM 09 40354 01/14/98 Cs-137 0.24E+00 1.34E+00 4.98E+00 TM 09 40354 01/14/98 Fe-59 5.81E+00 5.46E+00 1.83E+01 TM 09 40354 01/14/98 I-131 -1.47E-02 4.41E-02 0.28E+00 TM 09 40354 01/14/98 K-40 1.45E+03 7.62E+01 8.50E+01
- TM 09 40354 01/14/98 Mn-54 1.46E+00 1.52E+00 4.94E+00 TM 09 40354 01/14/98 Ru-103 -2.29E+00 1.48E+00 5.78E+00 TM 09 40354 01/14/98 Ru-106 1.62E+01 1.44E+01 4.88E+01 TM 09 40354 01/14/98 Sb-124 -3.31E+00 3.35E+00 1.51E+01 TM 09 40354 01/14/98 Se-75 1.56E+00 1.84E+00 6.00E+00 TM 09 40354 01/14/98 Th-232 1.52E+00 5.23E+00 1.86E+01 )
! TM 09 40354 01/14/98 Zn-65 -7.94E+00 3.99E+00 1.63E+01 ' TM 09 40354 01/14/98 Zr-95 -2.24E+00 2.49E+00 9.48E+00 TM 09 40874 02/11/98 Ag-110M -1.28E+00 1.29E+00 4.77E+00 , TM 09 40874 02/11/98 Ba-140 -0.45E+00 1.35E+00 5.22E+00 I TM 09 40874 02/11/98 Be-7 1.57E+01 8.76E+00 2.72E+01 TM 09 40874 02/11/98 Ce-141 2.45E+00 1.81E+00 5.42E+00 l
- TM 09 40874 02/11/98 Ce-144 -0.16E+00 6.53E+00 2.05E+01 l TM 09 40874 02/11/98 Co-57 -0.30E+00 0.89E+00 2.80E+00
! TM 09 40874 02/11/98 Co-58 1.72E+00 1.12E+00 3.45E+00 TM 09 40874 02/11/98 Co-60 -0.29E+00 1.08E+00 4.02E+00
' TM 09 40874 02/11/98 Cr-51 7.56E+00 1.05E+01 3.44E+01 TM 09 40874 02/11/98 Cs-134 0.26E+00 0.97E+00 3.23E+00 TM 09 40874~ 02/11/98 Cs-137 2.37E+00 1.25E+00 4.04E+00 TM 09 40874 02/11/98 Fe-59 -1.44E+00 3.09E+00 1.15E+01 '
TM. 09 40874 02/11/98 I-131 -2.73E-02 4.26E-02 0.29E+00 TM 09 40874 02/11/98 K-40 1.35E+03 5.33E+01 5.92E+01
- TM 09 40874- 02/11/98 Mn-54 -0.57E+00 1.04E+00 3.67E+00 TM 09 40874 02/11/98 Ru-103 -0.43E+00 1.12E+00 3.94E+00 TM 09 40874 02/11/98 Ru-106 -1.30E+01 9.50E+00 3.70E+01 TM 09 '40874 02/11/98 Sb-124 -4.10E+00 2.34E+00 9.91E+00 TM 09 40874 02/11/98 Se-75 1.60E+00 10E+00 4.49E+00
. TM 09 40874 02/11/98 Th-232 -5.33E+00 ; LE+00 1.44E+01 TM 09 40874 02/11/98 Zn-65 -1.72E+00 A.-lE+00 9.76E+00 TM 09 40874 02/11/98 Zr-95 2.33E+00 1.75E+00 5.49E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station 1 l Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pci/kg) (pCi/kg)' TM 09 41332 03/11/98 Ag-110M 1.00E+00 2.72E+00 9.31E+JO TM 09 41332 03/11/98 Ba-140 1.27E+00 1.93E+00 7.24Fe00 TM 09 41332 03/11/98 Be-7. 1.18E+01 1.49E+01 4.98E+01 TM 09 41332 03/11/98 Ce-141 0.30E+00 2.79E+00 8.86E+00 TM 09 41332 03/11/98 Ce-144 0.28E+00 9.92E+00 3 14E+01 TM 09 41332 03/11/98 Co-57 -1.14E+00 1.28E+00 4.19E+00 TM 09 41332 03/11/98 Co-58 1.13E+00 1.93E+00 6.51E+00 TM 09 41332 03/11/98 Co-60 0.42E+00 2.04E+00 7.62E+00 TM 09 41332 03/11/98 Cr-51 2.95E+01 1.65E+01 5.12E+01 TM 09 41332 03/11/98 Cs-134 -0.88E+00 1.16E+00 4.32E+00 TM 09 41332 03/11/98 Cs-137 2.22E+00 1.88E+00 6.39E+00 TM 09 41332 03/11/98 Fe-59 6.76E+00 6.17E+00 2.07E+01 TM 09 41332 03/11/98 I-131 6.04E-02 5.24E-02 0.23E+00 TM 09 41332 03/11/98 K-40 1.34E+03 8.45E+01 1.03E+02
- TM 09 41332 03/11/98 Mn-54 2.16E+00 1.83E+00 5.83E+00 TM 09 41332 03/11/98 Ru-103 2.27E+00 1.70E+00 5.46E+00 TM 09 41332 03/11/98 Ru-106 1.04E+01 1.46E+01 5.20E+01 TM 09 4133? 03/11/98 Sb-124 0.20E+00 3.48E+00 1.42E+01 TM 09 41332 03/11/98 Se-75 0.19E+00 2.17E+00 7.39E+00 t TM 09 41332 03/11/98 Th-232 2.22E+00 6.88E+00 2.42E+01 l TM 09 41332 03/11/98 Zn-65 1.56E+00 4.87E+00 1.73E+01 TM 09 41332 03/11/98 Zr-95 -2.98E+00 3.32E+00 1.34E+01 i l
TM 09 41604 04/08/98 Ag-110M 0.54E+00 1.55E+00 5.44E+00 TM 09 41604 04/08/98 Ba-140 0.57E+00 1.23E+00 4.61E+00
)
i TM 09 41604 04/08/98 Be-7 4.32E+00 9.48E+00 3.21E+01 J TM 09 41604 04/08/98 Ce-141 -0.91E+00 2.09E+00 6.77E+00 TM 09 41604 04/08/98 Ce-144 -0.55E+00 7.60E+00 2.39E+01 TM : 41604 04/08/98 Co-57 0.40E+00 0.98E+00 3.03E+00 TM % 41604 04/08/98 Co-58 -0.99E+00 1.20E+00 4.32E+00 TM 09 41604 04/08/98 Co-60 0.00E+00 1.34E+00 4.75E+00 TM 09 41604 04/08/98 Cr-51 -1.41E+00 1.04E+01 3.57E+C TM 09 41604 04/08/98 Cs-134 -0.60E+00 1.00E+00 3.53E+00 TM 09 41604 04/08/98 Cs-137 1.46E+00 1.42E+00 4.83E+00 TM 09 41604 04/08/98 Fe-59 -4.20E+00 4.15E+00 1.53E+01 TM 09 41604 04/08/98 I-131 -5.50E-02 3.46E-02 0.25E+00 TM 09 41604 04/08/98 K-40 1.39E+03 5.75E+01 5.59E+01
- TM 09 41604 04/08/98 Mn-54 -0.12E+00 1.07E+00 3.74E+00 TM 09 41604 04/08/98 Ru-103 -1.15E+00 1.23E+00 4.50E+00 TM 09 41604 04/08/98 Ru-106 1.37E+00 1.03E+01 3.74E+01 TM 09 41604 04/08/98 Sb-124 2.23E+00 2.45E+00 8.52E+00 TM 09 41604 04/08/98 Se-75 -1.25E+00 1.47E+00 5.13E+00 TM 09 41604 04/08/98 Th-232 1.39E+00 4.58E+00 1.60E+01 TM 09 41604 04/08/98 Zn-65 4.11E+00 2.93E+00 9.47E+00 TM 09 41604 04/08/98 Zr-95 3.50E+00 2.05E+00 6.21E+00 l
l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I i Seabrook Nuclear Power Station , Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 09 41903 04/22/98 Ag-110M -0.51E+00 1.75E+00 6.24E+00 TM 09 41903 04/22/98 Ba-140 0.11E+00 1.60E+00 6.37E+00 TM 09 41903 04/22/98 Be-7 -1.25E+00 1.02E+01 3.65E+01 TM 09 41903 04/22/98 Ce-141 -2.75E+00 2.00E+00 6.75E+00 TM 09 41903 04/22/98 Ce-144 2.90E+00 8.34E+00 2.60E+01 TM 09 41903 04/22/98 Co-57 -5.76E-02 1.00E+00 3.18E+00 TM 09 41903 04/22/98 Co-58 -0.22E+00 1.09E+00 3.98E+00 TM 09 41903 04/22/98 Co-60 -1.29E+00 1.35E+00 5.42E+00 TM 09 41903 04/22/98 Cr-51 1.06E+01 1.30E+01 4.28E+01 TM 09 41003 04/22/98 Cs-134 -0.58E+00 1.12E+00 4.26E+00 TM 09 41903 04/22/98 Cs-137 -3.74E-07 1.39E+00 5.10E+00 TM 09 41903 04/22/98. Fe-59 -3.42E+00 3.81E+00 1.51E+01 TM 09 41903 04/22/98 I-131 -2.96E-02 2.47E-02 0.21E+00 TM 09 41903 04/22/98 K-40 1.45E+03 6.58E+01 7.67E+01
- TM 09 41903 04/22/98 Mn-54 -1.71E+00 1.21E+00 4.64E+00 TM 09 41903 04/22/98 Ru-103 -2.10E+00 1.27E+00 4.96E+00 ;
TM 09 41903 04/22/98 Ru-106 -5.01E+00 1.07E+01 4.10E+01 TM 09 41903 04/22/98 Sb-124 1.93E+00 3.15E+00 1.11E+01 TM 09 41903 04/22/98 Se-75 0.70E+00 1.62E+00 5.39E+00 i TM 09 41903 04/22/98 Th-232 -2.07E+00 4.75E+00 1.73E+01 I TM 09 41903 04/22/98 Zn-65 -3.41E+00 2.77E+00 1.10E+01 TM 09 41903 04/22/98 Zr-95 2.17E+00 2.09E+00 6.77E+00 TM 09 42154 05/06/98 Ag-110M 0.20E+00 1.73E+00 5.96E+00 TM 09 42154 05/06/98 Ba-140 -4.05E+00 2.66E+00 1.16E+01 TM 09 42154 05/06/98 Be-7 1.61E+01 1.17E+01 3.74E+01 TM 09 42154 05/06/98 Ce-141 -2.13E+00 2.15E+00 6.94E+00 ) TM 09 42154 05/06/98 Ce-144 7.12E+00 7.34E+00 2.22E+01 l TM 09 42154 05/06/98 Co-57 0.25E+00 0.90E+00 2.79E+00 ! TM 09 42154 05/06/98 Co-58 0.41E+00 1.36E+00 4.61E+00 TM 09 42154 05/06/98 Co-60 -2.63E+00 1.78E+00 7.18E+00 TM 09 42154 05/06/98 Cr-51 7.78E+00 1.42E+01 4.69E+01 TM 09 42154 05/06/98 Cs-134 0.82E+00 0.97E+00 3.15E+00 ! TM 09 42154 05/06/98 Cs-137 1.73E+00 1.32E+00 4.41E+00 TM 09 42154 05/06/98 Fe-59 3.05E+00 4.19E+00 1.45E+01 , TM 09 42154 05/06/98 I-131 8.76E-02 7.08E-02 0.30E+00 TM 09 42154 05/06/98 K-40 1.49E+03 6.51E+01 6.65E+01
- TM 09 42154 05/06/98 Mn-54 -0.92E+00 1.20E+00 4.37E+00 TM 09 42154 05/06/98 Ru-103 2.05E+00 1.50E+00 4.77E+00 TM 09 42154 05/06/98 Ru-106 -1.03E+01 1.22E+01 4.62E+01 TM 09 42154 05/06/98 Sb-124 1.72E+00 3.73E+00 1.35E+01 TM 09 42154 05/06/98 Se-75 1.76E+00 1.63E+00 5.23E+00 TM 09 42154 05/06/98 Th-232 2.93E+00 5.27E+00 1.77E+01 TM 09 42154 05/06/98 Zn-65 2.68E+00 3.45E+00 1.17E+01 TM 09 42154 05/06/98 Zr-95 -0.53E+00 2.33E+00 8.19E+00 l
j
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program i Summary of 1998 Data SAMPLE CONC. STD DEV. MDC !' TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) l TM 09 42279 05/20/98 Ag-110M 0.29E+00 2.52E+00 9.13E+00 l TM 09 ' 4'79 05/20/98 Ba-140 -2.65E+00 2.29E+00 1.12E+01 TM 09 179 05/20/98 Be-7' -1.73E+01 1.34E+01 5.44E+01 , TM 09 ;79 05/20/98 Ce-141 1.16E+00 2.81E+00 8.92E+00 TM 09 .2279 05/20/98 Ce-144 7.76E+00 9.95E+00 3.08E+01 TM 09 42279 05/20/98 Co-57 0.47E+00 1.34E+00 4.22E+00 TM 09 42279 05/20/98 Co-58 -0.21E+00 1.48E+00 5.74E+00 TM 09 42279 05/20/98 Co-60 -0.72E+00 2.03E+00 8.32E+00 TM 09 42279 05/20/98 Cr-51 2.63E+00 1.71E+01 5.92E+01 TM 09 42279 05/20/98 Cs-134 -1.76E+00 1.55E+00 6.24E+00 l TM. 09 42279 05/20/98 Cs-137 1.53E+00 2.16E+00 7.67E+00 TM 09 42279 05/20/98 Fe-59 -1.11E+00 5.83E+00 2.30E+01 TM 90 9 42279 05/20/98 I-131 4.56E-02 4.76E-02 0.22E+00 TM 09 42279 05/20/98 K-40 1.41E+03 9.67E+01 1.34E+02
- TM 09 42279 05/20/98 Mn-54 2.90E+00 1.74E+00 5.26E+00 TM 09 42279 05/20/98 Ru-103 1.22E+00 1.77E+0C 6.08E+00 TM 09 42279 05/20/98 Ru-106 3.20E+00 1.66E+01 6.22E+01 TM 09 42279 05/20/98 Sb-124 1.00E+01 4.77E+00 1.25E+01 TM 09 42279 05/20/98 Se-75 -1.68E+00 2.36E+00 8.44E+00 TM 09 42279 05/20/98 Th-232 5.703+00 7.48E+00 2.56E+01 TM 09 42279 05/20/98 Zn-65 1.00E+00 5.23E+00 1.90E+01 TM 09 42279 05/20/98 Zr-95 -0.24E+00 3.53E+00 1.36E+01 TM 09 42586 06/03/98 Ag-110M -0.41E+00 1.31E+00 4.64E+00 TM 09 42586 06/03/98 Ba-140 -0.74E+00 1.89E+00 7.20E+00 1 TM 09 42586 06/03/98 Be-7 -1.14E+01 9.47E+00 3.46E+01 TM 09 42586 06/03/98 Ce-141 0.46E+00 2.02E+00 6.26E+00 TM 09 42586 06/03/98 Ce-144 -8.41E+00 6.79E+00 2.21E+01 TM 09 42586 06/03/98 Co-57 1.25E+00 0.90E+00 2.69E+00 TM 09 42586 06/03/98 Co-58 1.05E+00 1.02E+00 3.26E+00 TM 09 42586 06/03/98 Co-60 0.51E+00 0.94E+00 3.35E+00 TM 09 42586 06/03/98 Cr-51 -5.15E+00 1.10E+01 3.81E+01 TM 09 42586 06/03/98 Cs-134 -1.50E+00 0.94E+00 3.75E+00 TM 09 42586 06/03/98 Cs-137 1.10E+00 1.17E+00 3.95E+00 TM 09 42586 06/03/98 Fe-59 5.28E+00 3.69E+00 1.19E+01 TM 09 42586 06/03/98 I-131 0.35E+00 0.14E+00 0.40E+00
. TM 09 42586 06/03/98 K-40 1.43E+03 5.45E+01 5.68E+01
- TM 09 42586 06/03/98 Mn-54 -0.14E+00 1.03E+00 3.55E+00
?M 09 42586 06/03/98 Ru-103 -0.83E+00 1.21E+00 4.32E+00 TM 09 42586 06/03/98 Ru-106 -2.14E+01 9.79E+00 3.94E+01 TM 09 42586 06/03/98 Sb-124 -0.65E+00 1.85E+00 7.46E+00 TM 09 42586 06/03/98 Se-75 2.47E+00 1.30E+00 4.02E+00 TM 09 42586 06/03/98 Th-232 9.45E+00 4.19E+00 1.25E+01 TM 09 42586 06/03/98 Zn-65 2.26E+00 2.51E+00 8.42E+00 TM 09 42586 (3/03/98 Zr-95 -0.41E+00 1.67E+00 5.93E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pC1/kg) (pCi/kg) TM 09 42690 06/17/98 Ag-110M 2.42E+00 2.96E+00 1.01E+01 i TM 09 42690 06/17/98 Ba-140 -1.32E+00 1.18E+00 9.05E+00 } TM 09 42690 06/17/98 Be-7 3.08E+00 1.91E+01 6.90E+01 j TM 09 42690 06/17/98 Ce-141 -6.22E+00 3.15E+00 1.13E+01 l TM 09 42690 06/17/98 Ce-144 8.91E+00 1.32E+01 4.11E+01 1 TM 09 42690 06/17/98 Co-57 -0.77E+00 1.70E+00 5.60E+00 TM 09 42690 06/17/98 Co-58 0.15E+00 2.41E+00 8.87E+00 TM 09 42690 06/17/98 Co-60 2.49E+00 2.58E+00 9.04E+00 TM 09 42690 06/17/98 Cr-51 3.45E+01 2.36E+01 7.50E+01 TM 09 42G90 06/17/98 Cs-134 2.97E+00 1.49E+00 3.98E+00 TM 09 42600 06/17/98 Cs-137 3.24E+00 2.59E+00 8.78E+00 TM 09 42690 06/17/98 Fe-59 1.50E+01 7.72E+00 2.26E+01 TM 09 42690 06/17/98 I-131 -6.19E-03 6.2 5E-02 0.38E+00 TM 09 42690 06/17/98 K-40 1.19E+03 1.08E+02 1.78E+02
- TM 09 42690 06/17/98 Mn-54 -0.28E+00 1.97E+00 7.63E+00 TM 09 42690 06/17/98 Ru-103 -2.33E+00 2.46E+00 9.62E+00 TM 09 42690 06/17/98 Ru-106 4.93E+00 1.82E+01 7.00E+01 TM 09 42690 06/17/98 Sb-124 4.09E+00 5.96E+00 2.19E+01 TM 09 42690 06/17/98 Se-75 0.13E+00 2.90E+00 1.01E+01 l TM 09 42690 06/17/98 Th-232 -1.39E+01 7.44E+00 3.42E+01 TM 09 42690 06/17/98 Zn-65 -1.39E+00 4.24E+00 1.83E+01 l TM 09 42690 06/17/98 Zr-95 -1.99E+00 4.66E+00 1.87E+01 TM 09 42916 07/01/98 Ag-110M 3.05E+00 2.32E+00 7.32E+00 TM 09 42916 07/01/98 Ba-140 2.00E+00 2.72E+00 9.90E+00 TM 09 42916 07/01/98 Be-7 3.08E+01 1.42E+01 4.21E+01 TM 09 42916 07/01/98 Ce-141 -4.16E+00 2.59E+00 8.89E+00 TM 09 42916 07/01/98 Ce-144 -3.94E+00 8.46E+00 2.76E+01 TM 09 42916 07/01/98 Co-57 -0.16E+00 1.12E+00 ?.39E+00 TM 09 42916 07/01/98 Co-58 -0.34E+00 1.52E+00 5.65E+00 TM 09 42916 07/01/98 Co-60 -0.44E+00 2.12E+00 8.33E+00 TM 09 42916 07/01/98 Cr-51 -1.37E+01 1.66E+01 6.00E+01 TM 09 42916 07/01/98 Cs-134 -0.72E+00 1.54E+00 5.88E+00 TM 09 42916 07/01/98 Cs-137 2.34E+00 1.94E+00 6.56E+00 TM 09 42916 07/01/98 Fe-59 -4.52E+00 5.79E+00 2.32E+01 TM 03 42916 07/01/98 I-131 -3.03E-02 4.63E-02 0.38E+00 TM 09 42916 07/01/98 K-40 1.34E+03 8.16E+01 9.89E+01
- TM 09 42916 07/01/98 Mn-54 2.17E+00 1.48E+00 4.59E+00 TM 09 42916 07/01/98 Ru-103 -3.12E+C0 1.76E+00 7.03E+00 TM 09 42916 07/01/98 Ru-106 -1.49E+01 1.53E+01 6.07E+01 TM 09 42916 07/01/98 Sb-124 -0.77E+00 3.21E+00 1.42E+01 TM 09 42916 07/01/98 Se-75 0.40E+00 1.99E+00 6.75E+00 TM 09- 42916 07/01/98 Th-232 7.860+00 6.83E+00 2.23E+01 TM 09 42916 07/01/98 Zn-65 -2.66E+00 4.85E+00 1.82E+01 TM 09 42916 07/01/98 Zr-95 -0.53E+00 3.13E+00 1.13E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I ) i l Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kgs (pCi/kg) TM 09 43152 07/22/98 Ag-110M 0.36E+00 1.56E+00 5.42E+00 TM 09 43152 07/22/98 Ba-140 0.53E+00 1.76E+00 6.52E+00 TM 09 43152 07/22/98 Be-7 _ 1.26E+01 1.11E+01 3.58E+01 i TM' 10 9 43152 07/22/98 Ce-141 -0.67E+00 1.94E+00 6.20E+00 l TM 09 43152 07/22/98 Ce-144 7.60E+00 7.37E+00 2.23E+01 1 TM 09 43152 07/22/98 Co-57 -1.69E+00 0.98E+00 3.21E+00 j TM' 09 43152 07/22/98 Co-58 0.31E+00 1.34E+00 4.56E+00 TM 09 43152 07/22/98 Co-60 -0.58E+00 1.53E+00 5.80E+00 TM 09 43152 07/22/98 Cr-51 3.77E+00 1.07E+01 3.59E+01 TM 09 43152 07/22/98 Cs-134 0.45E+00 1.51E+00 4.95E+00 l TM 09 43152 07/22/98 Cs-137 7.05E+00 2.10E+00 7.00E+00
- l TM 09 43152 07/22/98 Fe-59 -1.85E+00 4.07E+00 1.55E+01 TM 09 43152 07/22/98 I-131 9.03E-02 9.90E-02 0.47E+00 1M 09 43152 07/22/98 K-40 1.34E+03 6.72E+01 9.37E+01
- TM 09 43152 07/22/98 Mn-54 0.75E+00 1.16E+00 3.89E+00 TM 09 43152 07/22/98 Ru-103 -2.96E+00 1.28E+00 5.04E+00 TM S9 43152 07/22/98 Ru-106 -1.12E+01 1.25E+01 4.77E+01 TM 09 43152 07/22/98 Sb-124 -7.54E+00 3.03E+00 1.42E+01 TM 09 43152 07/22/98 Se-75 -0.64E+00 1.65E+00 5.61E+00 TM 09 43152 07/22/98 Th-232 1.33E+01 5.46E+00 1.56E+01 TM 09 43152 07/22/98 Zn-65 -3.07E+00 3.35E+00 1.27E+01 TM 09 43152 07/22/98 Zr-95 2.15E+00 2.32E+00 8.05E+00 TM 09 43391 08/05/98 Ag-110M -4.06E+00 1.48E+00 6.22E+00 TM 09 43391 08/05/98 Ba-140 1.15E+00 1.66E+00 5.83E+00 TM. 09 43391 08/05/98 Be-7 1.23E+01 9.88E+00 3.18E+01 TM 09 43391 08/05/98 Ce-141 -0.21E+00 1.78E+00 5.61E+00 TM 09 43391 08/05/98 Ce-144 9.18E+00 6.63E+00 1.98E+01 TM. 09 43391 08/05/98 Co-57 -0.35E+00 0.83E+00 2.62E+00 TM 09 43391 08/05/98 Co-58 9.62E-02 1.21E+00 4.20E+00 TM 09 43391 08/05/98 Co-60 0.79E+00 1.61E+00 5.80E+00 TM 09 43391 08/05/98 Cr-51 4.54E+00 1.04E+01 3.48E+01 TM 09 43391 08/05/98 Cs-134 0.29E+00 1.13E+00 4.03E+00 TM. 09 43391 08/05/98 Cs-137 3.33E+00 1.37E+00 4.21E+00 TM 09 43391 08/05/98 Fe-59 2.46E+00 4.19E+00 1.45E+01 TM 09 43391 08/05/98 I-131 -1.34E-02 6.26E-02 0.48E+00 TM 09 43391 08/05/98 K-40 1.13E+03 5.85E+01 7.44E+01
- TM 09 43391 08/05/98 Mn-54 ' -2.11E+00 1.06E+00 4.23E+00 TM 09 43391 08/05/98 Ru-103 -2.67E+00 1.12E+00 4.47E+00 TM 09 43391 08/05/98 Ru-106 9.38E+00 1.04E+01 3.58E+01 TM 09 43391 08/05/98 Sb-124 -0.66E+00 2.71E+00 1.09E+01 TM 09 43391- 08/05/98 Se-75 2.36E+00 1.42E+00 4.45E+00 TM 09 43391 08/05/98 Th-232 1.10E+01 4.74E+00 1.36E+01 TM 09 43391 08/05/98 Zn-65 0.12E+00 3.27E+00 1.16E+01 TM 09 43391 08/05/98 Zr-95 -1.48E+00 1.95E+00 7.19E+00 l
I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 09 43688 08/19/98 Ag-110M -2.22E+00 1.87E+00 7.32E+00 TM 09 43688 08/19/98 Ba-140 -3.37E+00 1.81E+00 9.00E+00 l TM 09 43688 08/19/98 Be-7 7.24E+00 1.18E+01 4.02E+01 TM 09 43688 08/19/98 Ce-141 1.87E+00 2.51E+00 7.75E+00 TM 09 43688 08/19/98 Ce-144 -2.76E+01 9.20E+00 3.29E+01 TM 09 43688 08/19/98 Co-57 -0.81E+00 1.15E+00 3.78E+00 TM 09 43688 08/19/98 Co-58 0.44E+00 1.56E+00 5.36E+00 TM 09 43688 08/19/98 Co-60 0.22E+00 1.62E+00 6.02E+00 l TM 09 43688 08/19/98 Cr-51 -2.13E+01 1.35E+01 5.13E+01 l TM 09 43688 08/19/98 Cs-134 -0.73E+00 1.33E+00 4.78E+00 TM 09 43683 08/19/98 Cs-137 6.01E+00 2.51E+00 8.70E+00 TM 09 43688 08/19/98 Fe-59 1.50E+00 3.65E+00 1.35E+01 TM 09 43688 08/19/98 I-131 4.88E-02 3.74E-02 0.15E+00 TM 09 43688 08/19/98 K-4C 1.23E+03 6.83E+01 7.67E+01
- TM 09 43688 08/19/98 Mn-54 1.67E+00 1.28E+00 4.04E+00 TM 09 43688 08/19/98 Ru-103 -0.64E+00 1.26E+00 4.80E+00 l
TM 09 43688 08/19/98 Ru-106 1.84E+00 9.31E+00 3.57E+01 TM 09 43688 08/19/98 Sb-124 1.32E+00 1.49E+00 5.59E+00 TM 09 43688 08/19/98 Se-75 -3.43E-02 1.953+00 6.69E+00 TM 09 43688 08/19/98 Th-232 3.12E+00 5.10E+00 1.76E+01 TM 09 43688 08/19/98 Zn-65 -3.63E+00 3.58E+00 1.40E+01 TM 09 43688 08/19/98 Zr-95 0.12E+00 1.98E+00 7.29E+00 , TM 09 43976 09/02/98 Ag-110M -0.69E+00 1.41E+00 5.23E+00 l TM 09 43976 09/02/98 Ba-140 -1.13E+00 1.69E+00 7.13E+00 TM 09 43976 09/02/98 Be-7 -8.49E+00 8.93E+00 3.39E+01 TM 09 43976 09/02/98 Ce-141 0.60E+00 1.91E+00 6.02E+00 TM 09 43976 09/02/98 Ce-144 -0.63E+00 6.82E+00 2.19E+01 ! TM 09 43976 09/02/98 Co-57 0.49E+00 0.90E+00 2.81E+00 l TM 09 43976 09/02/98 Co-58 -0.15E+00 1.06E+00 3.84E+00 l TM 09 43976 09/02/98 Co-60 -0.39E+00 1.10E+00 4.32E+00 TM 09 43976 09/02/98 Cr-51 1.55E+00 1.01E+01 3.50E+01 TM 09 43976 09/02/98 Cs-134 0.92E+00 1.08E+00 3.76E+00 TM 09 43976 09/02/98 Cs-137 1.85E+00 1.31E+00 4.35E+00 TM 09 43976 09/02/98 Fe-59 -2.02E+00 4.33E+00 1.62E+01 TM 09 43976 09/02/98 I-131 3.81E-02 5.66E-02 0.28E+00 , TM 09 43976 09/02/98 K-40 1.35E+03 6.21E+01 7.69E+01
- l TM 09 43976 09/02/98 Mn-54 -0.86E+00 1.12E+00 4.15E+00 TM 09 43976 09/02/98 Ru-103 -0.12E+00 1.23E+00 4.37E+00 l TM 09 43976 09/02/98 Ru-106 1.57E+00 9.31E+00 3.45E+01 l TM 09 43976 09/02/98 Sb-124 1.39E+00 1.94E+00 7.07E+00 TM 09 43976 09/02/98 Se-75 1.25E+00 1.47E+00 4.82E+00 TM 09 43976 09/02/98 Th-232 -0.89E+00 4.42E+00 1.59E+01 TM 09 43976 09/02/98 Zn-65 0.75E+00 2.77E+00 9.85E+00 TM 09 43976 09/02/98 Zr-95 1.78E+00 2.28E+00 8.01E+00 1
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
t
E l l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) l TM 09 44364 09/23/98 Ag-110M 0.00E+00 2.20E+00 7.69E+00 l TM 09 44364 09/23/98 Ba-140 1.89E+00 1.82E+00 6.24E+00 TM 09 44364 09/23/98 Be-7 -1.97E+00 1.22E+01 4.32E+01 l TM 09 44364 09/23/98 Ce-141 -1.15E+00 2.24E+00 7.24E+00 1 TM 09 44364 09/23/98 Ce-144 -4.86E+00 8.03E+00 2.59E+01 TM 09 44364 09/23/98 Co-57 -5.35E-02 1.06E+00 3.34E+00 ! TM 09 44364 09/23/98 Co-58 -0.73E+00 1.68E+00 6.00E+00 TM 09 44364 09/23/98 Co-60 1.13E+00 1.53E+00 5.38E+00 TM 09 44364 09/23/98 Cr-51 7.00E+00 1.19E+01 3.99E+01 l TM 09 44364 09/23/98 Cs-134 -1.22E+00 1.17E+00 4.20E+00 TM 09 44364 09/23/98 Cs-137 4.30E+00 1.78E+00 5.47E+00 TM 09 44364 09/23/98 Fe-59 -5.04E+00 5.06E+00 2.00E+01 TM 09 44364 09/23/98 I-131 8.98E-02 7.63E-02 0.33E+00 TM 09 44364 09/23/98 K-40 1.46E+03 7.58E+01 8.07E+01
- TM 09 44364 09/23/98 Mn-54 -0.81E+00 1.42E+00 5.22E+00 TM 09 44364 09/23/98 Ru-103 -2.20E+00 1.65E+00 6.17E+00 TM 09 44364 09/23/98 Ru-106 -8.01E+00 1.23E+01 4.81E+01 ;
TM 09 44364 09'23/98 Sb-124 -5.76E+00 4.12E+00 1.75E+01 1 TM 09 44364 09/23/98 Se-75 -1.37E+00 1.81E+00 6.34E+00 l TM 09 44364 09/23/98 Th-232 1.43E+C0 6.42E+00 2.22E+01 TM 09 44364 09/23/98 Zn-65 2.28E+00 4.58E+00 1.58E+01 TM 09 44364 09/23/98 Zr-95 -2.26E+00 2.978+00 1.15E+01 TM 09 45109 10/14/98 Ag-110M -0.56E+00 1.20E+00 4.17E+00 TM 09 45109 10/14/98 Ba-140 -2.70E+00 1.45E+00 5.96E+00 TM 09 45109 10/14/98 Be-7 -1.25E+01 8.00E+00 2.90E+01 TM 09 45109 10/14/98 Ce-141 -9.58E-02 1.54E+00 4.80E+00 TM 09 45109 10/14/98 Ce-144 8.77E+00 5.73E+00 1.70E+01 TM 09 45109 10/14/98 Co-57 -0.31E+00 0.72E+00 2.27E+00 TM 09 45109 10/14/98 Co-58 0.31E+00 0.78E+00 2.59E+00 TM 09 45109 10/14/98 Co-60 -0.75E+00 0.90E+00 3.41E+00 TM 09 45109 10/14/98 Cr-51 -1.68E+00 8.82E+00 2.98E+01 TM 09 45109 10/14/98 Cs-134 1.16E+00 1.00E+00 3.01E+00 TM 09 45109 10/14/98 Cs-137 3.91E+00 1.60E+00 5.48E+00 TM 09 45109 10/14/98 Fe-59 1.79E+00 2.78E+00 9.44E+00 TM 09 45109 10/14/98 I-131 0.11E+00 9.69E-02 0.42E+00 TM 09 45109 10/14/98 K-40 1.36E+03 4.50E+01 4.32E+01
- TM 09 45109 10/14/98 Mn-54 1.72E+00 0.81E+00 2.40E+00 TM 09 45109 10/14/98 Ru-103 -1.98E+00 0.95E+00 3.56E+00 TM 09 45109 10/14/98 Ru-106 -3.41E+00 8.18E+00 2.98E+01 TM 09 45109 10/14/98 Sb-124 -0.69E+00 1.43E+00 5.75E+00 TM 09 45109 10/14/98 Se-75 1.02E+00 1.17E+00 3.77E+00 TM 09 45109 10/14/98 Th-232 1.06E+00 2.87E+00 9.81E+00 TM 09 45109 10/14/98 Zn-65 -1.62E+00 2.21E+00 7.99E+00 TM 09 45109 10/14/98 Zr-95 1.21E+00 1.50E+00 4.83E+00 I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
E
)
l l l l l l Seabrook Nuclear Power Station i Radiological Environmental Monitoring Program i Summary of 1998 Data l l SAMPLE CONC. STD DEV. MDC I TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) I TM 09 45706 11/18/98 Ag-110M 3.24E+00 1.81E+00 5.40E+00 TM 09 45706 11/18/98 Ba-140 4.67E+00 2.34E+00 6.73E+00 TM 09 45706 11/18/98 Be-7 -7.40E+00 1.05E+01 3.90E+01 TM 09 45706 11/18/98 Ce-141 -3.54E+00 2.19E+00 7.44E+00 TM 09 45706 11/18/98 Ce-144 -1.35E+01 7.56E+00 2.57E+01 TM 09 45706 11/18/98 Co-57 2.20E+00 1.04E+00 3.02E+00 TM 09 45706 11/18/98 Co-58 -0.24E+00 1.34E+00 4.81E+00 TM 09 45706 11/18/98 Co-60 0.85E+00 1.98E+00 6.94E+00 l TM 09 45706 11/18/98 Cr-51 -0.23E+00 1.33E+01 4.54E+01 TM 09 45706 11/18/98 Cs-134 -0.74E+00 1.42E+00 5.25E+00 TM 09 45706 11/18/98 Cs-137 2.65E+00 1.74E+00 5.73E+00 TM 09 45706 11/18/98 Fe-59 -4.14E+00 5.10E+00 1.96E+01 I TM 09 45706 11/18/98 I-131 -4.38E-02 4.23E-02 0.37E+00 TM 09 45706 11/18/98 K-40 1.40E+03 7.09E+01 8.18E+01
- l TM 09 4s706 11/18/98 Mn-54 0.63E+00 1.32E+00 4.47E+00 TM 09 45706 11/18/98 Ru-103 -2.50E+00 1.62E+00 6.08E+00 TM 09 45706 11/18/98 Ru-106 1.49E+01 1.15E+01 3.85E+01 l TM 09 45706 11/18/98 Sb-124 3.56E+00 2.97E+00 9.80E+00 TM 09 45706 11/18/98 Se-75 0.2SE+00 1.57E+00 5.35E+00 TM 09 45706 11/18/98 Th-232 0.87E+00 5.53E+00 1.93E+01 TM 09 45706 11/18/98 Zn-65 -2.21E+00 3.48E+00 1.32E+01 TM 09 45706 11/18/98 Zr-95 3.65E+00 2.61E+00 8.12E+00 TM 09 46233 12/16/98 Ag-110M -2.45E+00 2.06E+00 8.08E+00 TM 09 46233 12/16/98 Ba-140 -0.87E+00 3.19E+00 1.26E+01 TM 09 46233 12/16/98 Be-7 -2.30E+00 1.43E+01 5.06E+01 TM 09 46233 12/16/98 Ce-141 3.95E+00 2.72E+00 8.19E+00 TM 09 46233 12/16/98 Ce-144 3.80E+00 8.62E+00 2.68E+01 TM 09 46233 12/16/98 Co-57 -1.02E+00 1.10E+00 3.59E+00 TM 09 46233 12/16/98 Co-58 -1.22E+00 1.60E+00 6.04E+00 TM 09 46233 12/16/98 Co-60 -0.55E+00 1.79E+00 6.97E+00 TM 09 46233 12/16/98 Cr-51 -2.41E+01 1.79E+01 6.46E+01 TM 09 46233 12/16/98 Cs-134 -1.60E+00 1.23E+00 4.53E+00 TM 09 46233 12/16/98 Cs-137 3.71E+00 1.87E+00 5.94E+00 TM 09 46233 12/16/98 Fe-59 5.13E+00 5.65E+00 1.93E+01 TM 09 46233 12/16/98 I-131 -0.10E+00 3.84E-02 0. 3 3 E+ 0 0 ,
TM 09 46233 12/16/98 K-40 1.19E+03 7.57E+01 1.14E+02
- TM 09 46233 12/16/98 Mn-54 0.35E+00 1.36E+00 4.80E+00 TM 09 46233 12/16/98 Ru-103 -0.13E+00 1.62E+00 5.80E+00 TM 09 46233 12/16/98 Ru-106 8.96E+00 1.38E+01 4.90E+01 TM 09 46233 12/16/98 Sb-124 2.54E+00 3.80E+00 1.37E+01 TM 09 46233 12/16/98 Se-75 1.30E+00 2.16E+00 7.13E+00 TM 09 46233 12/16/98 Th-232 -3.96E+00 5.96E+00 2.24E+01 TM 09 46233 12/16/98 Zn-65 -1.94E+00 4.46E+00 1.66E+01 TM 09 46233 12/16/98 Zr-95 -1.58E+00 3.37E+00 1.29E+01
(
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 15 40355 01/14/98 Ag-110M 1.19E+00 1.64E+00 5.44E400 TM 15 40355 01/14/98 Ba-140 3.16E+00 2.36E+00 7.55E+00 TM 15 40355 01/14/98 Be-7 -6.38E+00 9.71E+00 3.61E+01 TM 15 40355 01/14/98 Ce-141 1.40E+00 2.46E+00 7.58E+00 TM 15 40355 01/14/98 Ce-144 -4.11E+00 8.32E+00 2.68E+01 TM 15 40355 01/14/98 Co-57 0.38E+00 1.09E+00 3.41E+00 TM 15 40355 01/14/98 Co-58 0.95E+00 1.32E+00 4.37E+00 TM 15 40355 01/14/98 Co-60 1.81E+00 1.42E+00 4.67E+00 TM 15 40355 01/14/98 Cr-51 1.43E+00 1.45E+01 4.90E+01 TM 15 40355 01/14/98 Cs-134 0.58E+00 1.09E+00 3.63E+00 TM 15 40355 01/14/98 Cs-137 5.63E+00 2.21E+00 7.78E+00 TM 15 40355 01/14/98 Fe-59 -1.32E+00 3.98E+00 1.51E+01 TM 15 40355 01/14/98 I-131 -2.90E-03 5.29F-02 0.34E+00 TM 15 40355 01/14/98 K-40 1.29E+03 6.27E+01 7.12E+01
- TM 15 40355 01/14/98 Mn-F4 -0.77E+00 1.21E+00 4.43E+00 TM 15 40355 01/14/98 Ru 103 0.62E+00 1.39E+00 4.73E+00 TM 15 40355 01/14/98 Ru -106 1.37E+01 1.16E+01 3.93E+01 TM 15 40355 01/14/98 Sb-124 -0.92E+00 2.62E+00 1.06E+01 TM 15 40355 01/14/98 Se-75 -2.77E-02 1.73E+00 S.87E+00 TM 15 40355 01/14/98 Th-232 2.69E+00 4.69E+00 1.60E+01 TM 15 40355 01/14/od Zn-65 1.84E+01 7.00E+00 2.53E+01 TM 15 40355 01/14<98 Zr-95 -0.87E+00 2.39E+00 8.54E+00 TM 15 40875 02/11/98 Ag-110M -1.65E+00 1.60E+00 5.93E+00 TM 15 40875 02/11/98 Ba-140 0.96E+00 1.45E+00 5.15E+00 TM 15 40875 02/11/98 Be-7 2.81E+00 8.58E+00 2.91E+01 TM 15 40875 02/11/98 Ce-141 -5.14E+00 1.94E+00 6.61E+00 TM 15 40875 07./11/98 Ce-144 3.51E+00 6.89E+00 2.12E+01 TM 15 40875 02/11/98 Co-57 -0.66E+00 0.88E+00 2.81E+00 TM 13 40875 02/11/98 Co-58 7.24E-02 1.13E+00 3.82E+00 TM 15 40875 02/11/98 Co-60 -0.82E+00 1.22E+00 4.47E+00 TM 15 40875 02/11/98 Cr-51 -4.65E+03 9.93E+00 3.42E+01 TM 15 40875 02/11/98 Cs-134 -1.45E+00 1.02E+00 3.93E+00 TM 15 40875 02/11/98 Cs-137 2.29E+00 1.32E+00 4.29E+00 TM 15 40875 02/11/98 Fe-59 4.05E+00 3.32E+00 1.06E+01 TM 15 40875 02/11/98 I-131 -8.21E-03 6.68E-02 0.36E+00 TM 15 40875 02/11/98 K-40 1.48E+03 5.53E+01 6.55E+01
- TM 15 40875 02/11/98 Mn-54 -0.69E+00 1.05E+00 3.69E.+00 TM 15 40875 02/11/98 Ru-103 -1.62E+00 1.07E+00 4.02E+00 TM 15 40875 02/11/98 Ru 106 -7.99E+00 1.03E+01 3.83E+01 TM 15 40875 02/11/98 Sb-124 -1.13E+00 2.46E+00 9.56E+00 TM 15 40875 02/11/98 Se-75 1.84E+00 1.40E+00 4.45E+00 TM 15 40875 02/11/98 Th-232 -2.71E+00 4.67E+00 1.68E+01 TM 15 40875 02/11/98 Zn-65 -0.87E+00 2.73E+00 9.74E+00 TM 15 40875 02/11/98 Zr-95 2.38E+00 1.75E+00 5.47E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pC1/kg) (pCi/kg) (pci/kg) TM 15 41333 03/11/98 Ag-110M -1.89E+00 2.26E+00 8.63E+00 TM 15 41333~ 03/11/98 Ba-140 2.62E+00 2.27E+00 7.56E+00 TM 15 41333 03/11/98 Be-7 -4.08E+00 1.35E+01 4.88E+01 TM 15 41333 03/11/98 Ce-141 -0.90E+00 2.67E+00 8.61E+00 TM 15 41333 03/11/98 Ce-144 -9.33E+00 9.25E+00 3.04E+01 TM 15 41333 03/11/98 Co-57 1.13E+00 1.29E+00 3.94E+00 TM 15 41333 03/11/98 Co-58 0.40E+00 1.87E+00 6.45E+00 TM 15 41333 03/11/98 Co-60 -1.32E+00 2.46E+00 9.66E+00 TM 15 41333 03/11/98 Cr-51 1.77E+01 1.52E+01 4.89E+01 TM 15 41333 03/11/98 Cs-134 -0.87E+00 4.11E+00 1.46E+01 TM 15 41333 03/11/98 Cs-137 2.61E+00 2.09E+00 7.03E+00 TM 15 41333 03/11/98 Fe-59 7.06E+00 5.38E+00 1.76E+01 TM 15 41333 03/11/98 I-131 -1.16E-02 3.59E-02 0.23E+00 TM 15 41333 03/11/98 K-40 1.56E+03 8.86E+01 1.12E+02
- TM 15 41333 03/11/98 Mn-54 -1.45E+00 1.62E+00 6.17E+00 TM 15 41333 03/11/98 Ru-103 1.71E+00 1.80E+00 5.95E+00 TM 15 41333 03/11/98 Ru-106 2.54E+01 1.69E+01 5.58E+01 TM 15 41333 03/11/98 Sb-124 2.76E+00 3.27E+00 1.20E+01 TM 15 41333 03/11/98 Se-75 3.73E+00 2.17E+00 6.80E+00 TM 15- 41333 03/11/98 Th-232 -1.17E+00 6.16E+00 2.27E+01 TM 15 41333 03/11/98 Zn-65 -2.40E+00 4.52E+00 1.71E+01 TM 15 41333 03/11/98 Zr-95 2.06E+00 2.94E+00 9.83E+00 TM '15 41605 04/08/98 Ag-110M 1.39E+00 2.10E+00 7.06E+00 TM 15 41605 04/08/98 Ba-140 4.55E+00 1.96E+00 4.61E+00
- TM 15 41605 04/08/98 Be-7 -7.07E+00 1.22E+01 4.48E+01 ' TM 15 41605 04/08/98 Ce-141 -3.10E+C0 2.35E+00 7.84E+00 TM 15 41605 04/08/98 Ce-144 -5.16E+00 8.56E+00 2.77E+01 TM 15 41605 04/08/98 Co-57 -2.91E+00 1.15E+00 3.95E+00 TM 15 41605 04/08/98 Co-58 0.58E+00 1.68E+00 5.74E+00 TM 15 41605 04/08/98 Co-60 0.25E+00 1.88E+00 6.96E+00 TM 15 41605 04/08/98 Cr-51 -1.28E+01 1.49E+01 5.31E+01 TM 15 41605 04/08/98 Co-134 2.81E+00 1.49E+00 4.58E+00 TM 15 41605 04/08/98 Cs-137 7.41E+00 2.12E+00 6.01E+00
- TM 15 41605 04/08/98 Fe-59 -6.52E+00 5.42E+00 2.19E+01 TM 15 41605 04/08/98 I-131 1.13E-02 3.45E-02 0.19E+00 TM 15 41605 04/08/98 K-40 1.44E+03 8.18E+01 1.13E+02
- TM 15 41605 04/08/98 Mn-54 2.77E+00 1.79E+00 5.49E+00 TM 15 41605 04/08/98 Ru-103 -3.24E+00 1.48E+00 6.02E+00 TM 15 41605 04/08/98 Ru-106 0.00E+00 1.37E+01 5.10E+01 TM 15 41605 04/08/98 Sb-124 -0.65E+00 3.02E+00 1.27E+01 TM 15 41605 04/08/98 Se-75 0.47E+00 1.79E+00 6.06E+00 l
TM .15 41605 04/08/98 Th-232 -0.79E+00 6.23E+00 2.24E+01 TM 15 41605 04/08/98 Zn-65 -1.39E+00 4.26E+00 1.58E+01 -i TM 15 41605 -04/08/98 Zr-95 -2.98E+00 2.72E+00 1.12E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l
r Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 15 41904 04/22/98 Ag-110M -2.24E+00 1.59E+00 6.21E+00 TM 15 41904 04/22/98 Ba-140 1.18E+00 1.91E+00 6.84E+00 TM 15 41904 04/22/98 Be-7 1.12E+01 1.04E+01 3.41E+01 TM 15 41904 04/22/98 Ce-141 -0.31E+00 2.10E+00 6.72E+00 TM 15 41904 04/22/98 Ce-144 -0.67E+00 7.46E+00 2.38E+01 TM 15 41904 04/22/98 Co-57 1.49E+00 1.02E+00 3.05E+00 TM 15 41904 04/22/98 Co-58 1.08E+00 1.21E+00 3.96E+00 TM 15 41904 04/22/98 Co-60 2.18E+00 1.24E+00 3.82E+00 TM 15 41904 04/22/98 Cr-51 6.54E+00 1.29E+01 4.30E+01 TM 15 41904 04/22/98 Cs-134 -0.48E+00 1.24E+00 4.62E+00 TM 15 41904 04/22/98 Cs-137 3.71E+00 1.76E+00 5.99E+00 TM 15 41904 04/22/98 Fe-59 -1.75E+00 4.17E+00 1.57E+01 TM 15 41904 04/22/98 I-131 -3.96E-02 4.08E-02 0.26E+00 TM 15 41904 04/22/98 K-40 1.51E+03 6.62E+01 6.87E+01
- TM 15 41904 04/22/98 Mn-54 0.00E+00 1.21E+00 4.24E+00 TM 15 41904 04/22/98 Ru-103 -0.76E+00 1.09E+00 4.13E+00 TM J5 41904 04/22/98 Ru-106 -1.62E+01 1.10E+01 4.44E+01 TM 15 41904 04/22/98 Sb-124 1.49E+00 2.26E+00 8.20E+00 TM 15 41904 04/22/98 Se-75 -8.07E-02 1.65E+00 5.63E+00 TM 15 41904 04/22/98 Th-232 -4.29E+00 4.85E+00 1.81E+01 TM 15 41904 04/22/98 Zn-65 2.55E+00 3.36E+00 1.14E+01 TM 15 41904 04/22/98 Zr-95 1.97E+00 2.47E+00 8.07E+00 TM 15 42155 05/06/98 Ag-110M -0.59E+00 1.88E+00 6.66E+00 TM 15 42155 05/06/98 Ba-140 -0.15E+00 2.66E+00 1.03E+01 TM 15 42155 05/06/98 Be-7 -8.38E+00 1.16E+01 4.21E+01 TM 15 42155 05/06/98 Ce-141 -0.85E+00 2.34E+00 7.46E+00 TM 15 42155 05/06/98 Ce-144 -3.44E+00 7.74E+00 2.45E+01 TM 15 42155 05/06/98 Co-57 -0.26E+00 1.01E+00 3.16E+00 TM 15 42155 05/06/98 Co-58 -1.47E+00 1.40E+00 5.22E+00 TM 15 42155 05/06/98 Co-60 -1.88E+00 1.82E+00 7.01E+00 TM 15 42155 05/06/98 Cr-51 1.34E+01 1.31E+01 4.26E+01 TM 15 42155 05/06/98 Cs-134 -0.69E+00 1.03E+00 3.55E+00 TM 15 42155 05/06/98 Cs-137 2.29E+00 1.68E+00 5.61E+00 TM 15 42155 05/06/98 Fe-59 4.72E+00 5.31E+00 1.79E+01 TM 15 42155 05/06/98 I-131 5.28E-02 6.22E-02 0.29E+00 TM 15 42155 05/06/98 K-40 1.55E+03 7.02E+01 8.06E+01
- TM 15 42155 05/06/98 Mn-54 -1.27E+00 1.28E+00 4.75E+00 TM 15 42155 05/06/98 Ru-103 -1.96E+00 1.52E+00 5.66E+00 TM 15 42155 05/06/98 Ru-106 -6.49E+00 1.36E+01 5.03E+01 TM 15 42155 05/06/98 Sb-124 -2.42E+00 3.11E+00 1.30E+01 TM 15 42155 05/06/98 Se-75 -1.38E+00 1.69E+00 5.88E+00 TM 15 42155 05/06/98 Th-232 8.17E+00 5.53E+00 1.75E+01 TM 15 42155 05/06/98 Zn-65 0.71E+00 3.94E+00 1.38E+01 TM 15 42155 05/06/98 Zr-95 -0.68E+00 2.92E+00 1.08E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 15 42280 05/20/98 Ag-110M 0.14E+00 2.62E+00 9.44E+00 TM 15 42280 05/20/98 Ba-140 2.28E+00 1.60E+00 4.69E+00 TM 15 42280 05/20/98 Be-7 5.62E+00 1.45E+01 5.08E+01 TM 15 42280 05/20/98 Ce-141 2.86E+00 2.94E+00 9.13E+00 TM 15 42280 05/20/98 Ce-144 7.60E+00 1.14E+01 3.54E+01 TM 15 42280 05/20/98 Co-57 -2.61E+00 1.42E+00 4.91E+00 TM 15 42280 05/20/98 Co-58 0.41E+00 1.63E+00 5.89E+00 TM 15 42280 05/20/98 Co-60 -1.83E+00 2.29E+00 9.41E+00 TM 15. 42280 05/20/98 Cr-51 -2.62E+00 1.62E+01 5.76E+01 TM 15 42280 05/20/98 Cs-134 -2.33E+00 1.51E+00 6.07E+00 TM 15 42280 05/20/98 Cs-137 -0.37E+00 1.84E+00 7.16E+00 TM 15 42280 05/20/98 Fe-59 5.36E+00 5.42E+00 1.86E+01 TM 15 42280 05/20/98 I-131 3.83E-02 6.36E-02 0.33E+00 TM 15 42280 05/20/98 K-40 1.39E+03 9.03E+01 9.91E+01
- TM 15 42280 05/20/98 Mn-54 -1.05E+00 1.69E+00 6.52E+00 TM 15 42280 05/20/98 Ru-103 -1.41E+00 1.76E+00 6.79E+00 TM 15 42280 05/20/98 Ru-106 -1.24E+01 1.57E+01 6.40E+01 TM 15 42280 05/20/98 Sb-124 -6.70E+00 3.41E+00 1.83E+01 TM 15 42280 05/20/98 Se-75 -1.57E+00 2.32E+00 8.32E+00 TM 15 42280 05/20/98 Th-232 -7.24E+00 6.79E+00 2.73E+01 TM 15 42280 05/20/98 Zn-65 -8.76E+00 4.91E+00 2.07E+01 TM 15 42280 05/20/98 Zr-95 -4.45E+00 2.84E+00 1.20E+01 TM 15 42587 06/03/98 Ag-110M 0.39E+00 1.67E+00 5.80E+00 TM 15 42587 06/03/98 Ba *") -2.21E+00 2.40E+00 9.47E+00 TM 15 42587 06/03/98 Be ' -8.04E+00 9.31E+00 3.36E+01 TM 15 12587 06/03/98 Ce-141 -6.55E+00 2.20E+00 7.57E+00 TM 15 42587 06/03/98 Ce-144 9.70E+00 7.04E+00 2.10E+01 TM 15 42587 06/03/98 Co-57 -1.57E+00 0.92E+00 3.03E+00 TM 15 42587 06/03/98 Co-58 0.55E+00 1.15E+00 3.81E+00 TM 15 42587 06/03/98 Co-60 -0.11E+00 1.07E+00 3.86E+00 TM 15 42587 06/03/98 Cr-51 6.38E+00 1.23E+01 4.06E+01 TM 15 42587 06/03/98 Cs-134 -0.12E+00 1.02E+00 3.43E+00 TM 15 42587 06/03/98 Cs-137 3.05E+00 1.36E+00 4.30E+00 TM 15 42587 06/03/98 Fe-59 5.40E+00 4.20E+00 1.34E+01 TM 15 42587 06/03/98 I-131 -1.14E-02 6.16E-02 0.38E+00 TM 15 /2587 06/03/98 K-40 1.57E+03 5.71E+01 6.03E+01
- TM 15 42587 06/03/98 Mn-54 0.50E+00 0.99E+00 3.29E+00 TM 15 42587 06/03/98 Ru-103 -1.11E+00 1.27E+00 4.59E+00 TM 15 42587 06/03/98 Ru-106 -8.31E+00 1.01E+01 3.81E+01 TM 15 42587 06/03/98 Sb-124 -1.51E+00 2.27E+00 9.30E+00 TM 15 42587 06/03/98 Se-75 2.72E+00 1.54E+00 4.80E+00 TM 15 42587 06/03/98 Th-232 2.78E+00 4.53E+00 1.54E+01 TM 15 42587 06/03/98 Zn-65 0.26E+00 2.75E+00 9.62E+00 TM 15 42587 06/03/98 Zr-95 -1.92E+00 1.74E+00 6.47E+00 1
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
J
4 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 15 42691 06/18/98 Ag-110M 1.69E+00 2.00E+00 6.59E+00 TM 15 42691 06/18/98 Ba-140 -1.14E+00 1.30E+00 6.28E+00 TM 15 42691 06/18/98 Be-7 1.15E+01 1.10E+01 3.65E+01 TM 15 42691 06/18/98 Ce-141 -2.42E+00 2.50E+00 8.35E+00 TH 15 42691 06/18/98 Ce-144 -5.81E+00 8.90E+00 2.94E+01 TM 15 42691 06/18/98 Co-57 -1.23E+00 1.17E+00 3.91E+00 TM 15 42691 06/18/98 Co-58 -1.23E+00 1.35E+00 5.23E+00 TM 15 42691 06/18/98 Co-60 0.94E+00 1.17E+00 4.21E+00 TM 15 42691 06/18/98 Cr-51 -1.44E+01 1.27E+01 4.73E+01 TM 15 42691 06/18/98 Cs-134 2.54E+00 1.40E+00 4.20E+00 TM 15 42691 06/18/98 Cs-137 1.28E+00 1.52E+00 5.32E+00 TM 15 42691 06/18/98 Fe-59 2.87F+00 4.43E+00 1.56E+01 TM 15 42691 06/18/98 *.- 131 2.15E-02 5.25E-02 0.26E+00 l TM 15 42691 06/18/98 K-40 1.65E+03 7.97E+01 8.73E+01
- l TM 15 42691 06/18/98 Mn-54 -2.09E+00 1.40E+00 5.54E+00 l TM 15 42691 06/18/98 Ru-103 0.54E+00 1.51E+00 5.23E+00 1 "M 15 42691 06/18/98 Ru-106 6.51E+00 1.28E+01 4.62E+01 TM 15 42691 06/18/98 Sb-124 -3.01E+00 2.94E+00 1.30E+01 TM 15 42691 06/18/98 Se-75 0.62E+00 1.92E+00 6.48E+00 TM 15 42691 06/18/98 Th-232 0.25E+00 5.73E+00 2.03E+01 TM 15 42691- 06/18/98 In-65 -0.16E+00 3.89E+00 1.41E+01 TM 15 42691 06/18/98 Zr-95 6.12E+00 2.46E+00 7.14E+00 TM 15 42917 07/01/98 Ag-110M 0.11E+00 2.12E+00 7.61E+00 TM 15 42917 07/01/98 Ba-140 4.29E+00 3.71E+00 1.22E+01 TM 15 42917 07/01/98 Be-7 1.15E+01 1.30E+01 4.33E+01 TM 15 42917 07/01/98 Ce-141 -3.13E+00 2.65E+00 8.80E+00 TM 15 42917 07/01/98 Ce-144 -4.62E+00 8.91E+00 2.89E+01 TM 15 42917 07/01/98 Co-57 1.28E+00 1.26E+00 3.81E+00 TM 15~ 42917 07/01/98 Co-58 1.25E+00 1.62E+00 5.41E+00 TM 15 42917 07/01/98 Co-60 -2.62E+00 2.05E+00 8.79E+00 TM 15 42917 07/01/98 Cr-51 4.92E+00 1.55E+01 5.30E+01 TM 15 42917 07/01/98 Cs-134- -1.66E+00 1.40E+00 5.31E+00 TM 15 42917 07/01/98 Cs-137 4.04E+00 1.87E+00 5.80E+00 TM 15 42917 07/01/98 Fe-59 -2.13E+00 6.42E+00 2.43E+01 TM 15 42917 07/01/98 I-131 -2.48E-02 5.05E-02 0.33E+00 TM 15 42917 07/01/98 K-40 1.68E+03 8.87E+01 8.41E+01
- TM 15 42917 07/01/98 Mn-54 -1.61E+00 1.53E+00 5.95E+00 TM 15 42917 07/01/98 Ru-103 -4.65E-02 1.85E+00 6.58E+00 TM 15 42917 07/01/98 Ru-106 2.44E+00 1.53E+01 5.61E+01 TM 15 42917 07/01/98 Sb-124 5.57E+00 4.25E+00 1.40E+01 7M 15 42917 07/01/98 Se-75 1.57E+00 2.07E+00 6.80E+00 TM 15 42917 07/01/98 Th-232 -3.26E+00 6.79E+00 2.51E+01 TM 15 42917 07/01/98 Zn-65 0.29E+00 4.33E+00 1.58E+01 TM 15 42917 07/01/98 Zr-95 -2.78E+00 3.14E+00 1.19E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
r- 1 Seabrook Nuclear Power Station l Radiological Environmental Monitoring Program i Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 15 43153 07/23/98 Ag-110M -2.09E+00 1.80Er00 6.99E+00 TM 15 43153 07/23/98 Ba-140 0.00E+00 1.7Cd+00 6.76E+00 TM 15 43153 07/23/98 Be-7 3.29E+00 1.01E+01 3.48E+01 TM 15 43153 07/23/98 Ce-141 -3.88E+00 2.17E+00 7.43E+00 TM 15 43153 07/23/98 Ce-144 7.67E+00 8.24E+00 2.51E+01 TM 15 43153 07/23/98 Co-57 0.17E+00 1.08E+00 3.39E+00 TM 15 43153 07/23/98 Co-58 1.03E+00 1.25E+00 4.09E+00 TM 15 43153 07/23/98 Co-60 -0.75E+00 1.20E+00 4.70E+00 TM 15 43153 07/23/98 Cr-51 -1.69E+00 1.05E+01 3.67E+01 I TM 15 43153 07/23/98 Cs-134 3.21E+00 1.48E+00 3.77E+00 TM 15 43153 07/23/98 Cs-137 2.72E+00 1.72E+00 5.64E+00 TM 15 43153 07/23/98 Fe-59 -1.09E+00 4.56E+00 1.63E+01 TM 15 43153 07/23/98 I-131 0.12E+00 9.69E-02 0.39E+00 ) TM 15 43153 07/23/98 K-40 1.70E+03 7.06E+01 7.91E+01
- TM 15 43153 07/23/98 Mn-54 -0.44E+00 1.14E+00 4.11E+00 TM 15 43153 07/23/98 Ru-103 -1.85E+00 1.25E+00 4.81E+00 TM 15 43153 07/23/98 Ru-106 1.64E+00 1.32E+01 4.76E+01 TM 15 43153 07/23/98 Sb-124 -0.14E+00 2.58E+00 1.02E+01 TM 15 43153 07/23/98 Se-75 0.42E+00 1.66E+00 5.56E+00 TM 15 43153 07/23/98 Th-232 5.19E+00 4.77E+00 1.59E+01 TM 15 43153 07/23/98 Zn-65 -5.89E+00 3.31E+00 1.31E+01 TM 15 43153 07/23/98 Zr-95 5.81E+00 2.06E+00 5.46E+00 TM 15 43392 08/05/98 Ag-110M 0.82E+00 2.08E+00 7.21E+00 TM 15 43392 08/05/98 Ba-140 2.08E+00 1.87E+00 6.32E+00 TM 15 43392 08/05/98 Be-7 1.87E+01 1.02E+01 3.14E+01 TM 15 43392 08/05/98 Ce-141 1.50E+00 2.19E+00 6.74E+00 TM 15 43392 08/05/98 Ce-144 8.77E+00 8.00E+00 2.42E+01 TM 15 43392 08/05/98 Co-57 -0.39E+00 1.08E+00 3.44E+00 TM 15 43392 08/05/98 Co-58 -1.45E+00 1.32E+00 4.91E+00 TM 15 43392 08/05/98 Co-60 -1.23E+00 1.39E+00 5.39E+00 TM 15 43392 08/05/98 Cr-51 7.25E+00 1.18E+01 3.92E+01 TM 15 43392 08/05/98 Cs-134 -1.32E+00 1.11E+00 4.11E+00 TM 15 43392 08/05/98 Cs-137 2.91E+00 1.44E+00 4.57E+00 TM 15 43392 08/05/98 Fe-59 -5.23E+00 3.85E+00 1.52E+01 TM 15 43392 08/05/98 I-131 -7.07E-02 4.18E-02 0.40E+00 TM 15 43392 08/05/98 K-40 1.83E+03 7.27E+01 7.57E+01
- TM 15 43392 08/05/98 Mn-54 1.43E+00 1.16E+00 3.69E+00 TM 15 43392 08/05/98 Ru-103 -1.89E+00 1.34E+00 5.05E+00 TM 15 43392 08/05/98 Ru-106 1.81E+01 1.08E+01 3.50E+01 TM 15 43392 08/05/98 Sb-124 1.06E+00 2.24E+00 8.51E+00 TM 15 43392 08/05/98 Se-75 0.19E+00 1.82E+00 6.10E+00 i TM 15 43392 08/05/98 Th-232 7.23E+00 5.44E+00 1.78E+01 {
TM 15 43392 08/05/98 Zn-65 -1.31E+00 3.01E+00 1.12E+01 j TM 15 43392 08/05/98 Zr-95 2.24E+00 2.24E+00 7.23E+00 1 i l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. ) }
t i 1 i l t i
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 15 43689 08/19/98 Ag-110M -2.03E+00 1.79E+00 7.05E+00 TM 15 43689 08/19/98 Ba-140 0.49E+00 1.67E+00 6.65E+00 TM 15 43689 08/19/98 Be-7 -5.99E+00 1.07E+01 4.03E+01 TM 15 43689 08/19/98 Ce-141 -0.47E+00 2.51E+00 8.09E+00 TM 15 43689 08/19/98 Ce-144 -8.24E+00 8.73E+00 2.91E+01 TM 15 43689 08/19/98 Co-57 -2.09E+00 1.26E+00 4.27E+00 TM 15 43689 08/19/98 Co-58 2.54E+00 1.55E+00 4.70E+00 TM 15 43689 08/19/98 Co-60 1.85E+00 1.54E+00 5.11E+00 TM 15 43689 08/19/98 Cr-51 6.14E+00 1.49E+01 5.04E+01 TM 15 43689 08/19/98 Cs-134 0.36E+00 1.43E+00 4.84E+00 TM 15 43689 08/19/98 Cs-137 1.39E+00 1.67E+00 5.82E+00 TM 15 43689 08/19/98 Fe-59 0.81E+00 4.69E+00 1.72E+01 TM 15 43689 08/19/98 I-131 3.33E-02 6.44E-02 0.33E+00 TM 15 43689 08/19/98 K-40 1.72E+03 8.07E+01 9.13E+01
- TM 15 43689 08/19/98 Mn-54 1.86E+00 1.51E+00 4.79E+00 TM 15 43689 08/19/98 Ru-103 -0.20E+00 1.47E+00 5.30E+00 TM 15 43689 08/19/98 Ru-106 -8.51E+00 1.20E+01 4.78E+01 TM 15 43689 08/19/98 Sb-124 2.27E+00 3.33E+00 1.19E+01 TM 15 43689 08/19/98 Se-75 1.68E+00 1.98E+00 6.48E+00 TM 15 43689 08/19/98 Th-232 -2.16E+00 5.31E+00 1.97E+01 TM 15 43689 08/19/98 Zn-65 ' 45E+00
. 3.25E+00 1.41E+01 TM 15 43689 08/19/98 Zr-95 -1.07E+00 2.27E+00 8.55E+00 TM 15 43977 09/02/98 Ag-110M -1.43E+00 1.76E+00 6.68E+00 TM 15 43977 09/02/98 Ba-140 -0.79E+00 2.27E+00 9.18E+00 TM 15 43977 09/02/98 Be-7 -6.30E+00 1.08E+01 3.99E+01 TM 15 43977 09/02/98 Ce-141 0.81E+00 2.26E+00 7.07E+00 TM 15 43977 09/02/98 Ce-144 -1.23E+01 8.30E+00 2.76E+01 TM 15 43977 09/02/98 Co-57 0.00E+00 1.07E+00 3.38E+00 TM 15 43977 09/02/98 Co-58 -0.50E+00 1.23E+00 4.57E+00 TM 15 43977 09/02/98 Co-60 -1.99E+00 1.40E+00 6.01E+00 TM 15 43977 09/02/98 Cr-51 1.25E+00 1.35E+01 4.63E+01 TM 15 43977 09/02/98 Cs-134 -1.04E+00 1.11E+00 4.13E+00 TM 15 43977 09/02/98 Cs-137 0.22E+00 1.64E+00 5.93E+00 TM 15 43977 09/02/98 Fe-59 6.90E+00 3.71E+00 1.12E+01 TM 15 43977 09/02/98 I-131 -4.94E-02 4.24E-02 0.32E+00 TM 15 43977 09/02/98 K-40 1.59E+03 7.56E+01 8.73E+01
- TM- 15 43977 09/02/98 Mn-54 -0.81E+00 1.28E+00 4.74E+00 TM 15 43977 09/02/98 Ru-103 1.16E+00 1.44E+00 4.80E+00 TM 15 43977 09/02/98 Ru-106 1.87E+00 1.41E+01 5.10E+01 TM 15 43977 09/02/98 Sb-124 -4.77E+00 2.56E+00 1.27E+01 TM 15 43977 09/02/98 Se-75 2.83E+00 1.82E+00 5.73E+00 TM 15 43977 09/02/98 Th-232 1.74E+00 5.60E+00 1.93E+01 TM 15 43977 09/02/98 Zn-65 -1.80E+00 3.47E+00 1.31E+01 TM 15 43977 09/02/98 Zr-95 -4.73E+00 2.32E+00 1.01E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 15 44365 09/23/98 Ag-110M 2.31E+00 1.66E+00 5.19E+00 TM 15 44365 09/23/98 Ba-140 1.05E+00 1.54E+00 5.473+00 TM 15 44365 09/23/98 Be-7 -1.99E+01 8.96E+00 3.62E+01 TM 15 44365 09/23/98 Ce-141 -0.61E+00 2.02E+00 6.54E+00 TM 15 44365 09/23/98 Ce-144 -2.94E+00 7.78E+00 2.50E+01 TM 15 44365 09/23/98 Co-57 1.00E+00 1.01E+00 3.07E+00 TM 15 44365 09/23/98 Co-58 0.45E+00 1.09E+00 3.73E+00 TM 15 44365 09/23/98 Co-60 -0.19E+00 1.24E+00 4.68E+00 TM 15 44365 09/23/98 Cr-51 0.00E+00 1.12E+01 3.84E+01 TM 15 44365 09/23/98 Cs-134 0.15E+00 1.33E+00 4.50E+00 TM 15 44365 09/23/98 Cs-137 1.11E+00 1.31E+00 4.54E+00 TM 15 44365 09/23/98 Fe-59 -2.24E+00 3.73E+00 1.43E+01 TM 15 44365 09/23/98 I-131 -2.45E-02 3.33E-02 0.27E+00 TM 15 44365 09/23/98 K-40 1.75E+03 6.99E+01 7.66E+01
- TM 15 44365 09/23/98 Mn-54 0.47E+00 1.22E+00 4.12E+00 TM 15 44365 09/23/98 Ru-103 -0.20E+00 1.24E+00 4.38E+00 TM 15 44365 09/23/98 Ru-106 -4.69E+00 1.10E+01 4.14E+01 TM 15 44365 09/23/98 Sb-124 -3.98E+00 2.17E+00 1.03E+01 TM 15 44365 09/23/98 Se-75 1.41E+00 1.67E+00 5.43E+00 TM 15 44365 09/23/98 Th-232 -3.01E+00 4.55E+00 1.67E+01 TM 15 44365 09/23/98 Zn-65 0.46E+00 3.35E+00 1.18E+01 TM 15 44365 09/23/98 Zr-95 0.00E+00 2.24E+00 8.29E+00 TM 15 45110 10/14/98 Ag-110M -3.11E+00 1.15E+00 4.45E+00 TM 15 45110 10/14/98 Ba-140 0.44E+00 1.33E+00 4.74E+00 TM 15 45110 10/14/98 Be-7 -1.24E+00 6.72E+00 2.29E+01 TM 15 45110 10/14/98 Ce-141 -3.53E+00 1.54E+00 5.11E+00 TM 15 45110 10/14/98 Ce-144 3.87E+00 5.11E+00 1.55E+01
, TM 15 45110 10/14/98 Co-57 -0.84E+00 0.68E+00 2.16E+00 TM 15 45110 10/14/98 Co-58 0.20E+00 0.86E+00 2.84E+00 TM 15 45110 10/14/98 Co-60 -1.36E+00 0.80E+00 3.05E+00 TM 15 45110 10/14/98 Cr-51 0.78E+00 8.39E+00 2.78E+01 TM 15 45110 10/14/98 Cs-134 1.95E+00 0.90E+00 2.50E+00 TM 15 45110 10/14/98 Cs-137 0.40E+00 0.97E+00 3.35E+00 TM 15 45110 10/14/98 Fe-59 0.36E+00 2.63E+00 8.90E+00 TM 15 45110 10/14/98 I-131 0.31E+00 0.13E+00 0.37E+00 TM 15 45110 10/14/98 K-40 1.57E+03 4.38E+01 4.77E+01
- TM 15 45110 10/14/98 Mn-54 1.20E+00 0.77E+00 2.35E+00 TM 15 45110 10/14/98 Ru-103 -3.03E+00 0.89E+00 3.42E+00 TM 15 45110 10/14/98 Ru-106 -1.38E+00 7.23E+00 2.59E+01 TM 15 45110 10/14/98 Sb-124 -3.28E+00 1.64E+00 6.99E+00 TM 15 45110 10/14/98 Se-75 -1.07E+00 1.07E+00 3.65E+00 TM 15 45110 10/14/98 Th-232 3.13E+00 3.44E+00 1.14E+01 TM 15 45110 10/14/98 Zn-65 1.20E+00 2.23E+00 7.47E+00 TM 15 45110 10/14/98 Zr-95 1.09E+00 1.44E+00 4.63E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I I l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pci/kg) (pCi/kg) TM 15 45707 11/18/98 Ag-110M. 1.92E+00 2.26E+00 7.38E+00 l TM 15 45707 11/18/98 Ba-140 0.30E+00 1.42E+00 5.92E+00 TM 15 45707 11/18/98 Be-7 6.80E+00 1.08E+01 3.69E+01 l TM 15 45707 11/18/98 Ce-141 -0.23E+00 2.17E+00 6.89E+00
.TM 15 45707 11/18/98 Ce-144 -1.27E+01 8.27E+00 2.74E+01 TM 15 45707 11/18/98 Co-57 1.61E+00 1.07E+00 3.17E+00 TM 15 45707 11/18/98 Co-58 -1.66E+00 1.44E+00 5.54E+00 TM 15 45707 11/18/98 Co-60 0.62E+00 1.79E+00 6.67E+00 TM 15 45707 11/18/98 Cr-51 0.73E+00 1.37E+01 4.68E+01 TM 15 45707 11/18/98 Cs-134 -0.98E+00 1.46E+00 5.53E+00 TM 15 45707 11/18/98 Cs-137 0.48E+00 1.40E+00 5.12E+00 TM 15 45707 11/18/98 Fe-59 -1.06E+00 4.58E+00 1.75E+01 TM 15 45707 11/18/98 I-131 -3.80E-02 7.08E-02 0.47E+00 TM 15 45707 11/18/98 K-40 1.69E+03 8.21E+01 8.75E+01
- TM 15 45707 11/18/98 Mn-54 0.69E+00 1.45E+00 4.91E+00 TM 15 45707 11/18/98 Ru-103 0.43E+00 1.33E+00 4.66E+00 TM 15 45707 11/18/98 Ru-106 2.62E+01 1.41E+01 4.53E+01 TM 15 45707 11/18/98 Sb-124 4.67E+00 2.69E+00 7.82E+00 TM 15 45707 11/18/98 Se-75 -1.51E+00 1.70E+00 6.03E+00 TM 15 45707 11/18/98 Th-232 -2.40E+00 6.18E+00 2.24E+01 TM 15 45707 11/18/98 Zn-65 3.17E+00 4.22E+00 1.44E+01 TM 15 45707 11/18/98 Zr-95 -1.71E+00 2.67E+00 9.81E+00 TM 15 46234 12/16/98 Ag-110M -0.36E+00 1.24E+00 4.19E+00 TM 15 46234 12/16/98 Ba-140 0.14E+00 1.40E+00 4.97E+00 TM 15 46234 12/16/98 Be-7 -7.02E+00 6.88E+00 2.42E+01 TM 15 46234 12/16/98 Ce-141 -0.68E+00 1.30E+00 4.03E+00 TM 15 46234 12/16/98 Ce-144 3.51E+00 4.94E+00 1.49E+01 TM 15 46234 12/16/98 Co-57 -0.18E+00 0.62E+00 1.92E+00 TM 15 46234 12/16/98 Co-58 -1.40E+00 0.91E+00 3.24E+00 TM 15 46234 12/16/98 Co-60 -0.13E+00 1.16E+00 4.21E+00 TM 15 46234 12/16/98 Cr-51 -1.05E+01 7.78E+00 2.70E+01 TM 15 46234 12/16/98 Cs-134 1.20E+00 0.89E+00 2.63E+00 TM 15 46234 12/16/98 Cs-137 -0.17E+00 0.90E+00 3.22E+00 TM 15 46234 12/16/98 Fe-59 -0.61E+00 2.84E+00 1.01E+01 TM 15 46234 12/16/98 I-131 -1.61E-02 3.56E-02 0.24E+00 TM 15 46234 12/16/98 K-40 1.46E+03 4.60E+01 5.04E+01
- TM 15 46234 12/16/98 Mn-54 -1.05E+00 0.76E+00 2.75E+00 TM 15 46234 12/16/98 Ru-103 -0.66E+00 0.95E+00 3.26E+00 TM 15 46234 12/16/98 Ru-106 -3.64E+00 8.53E+00 3.07E+01 TM 15 46234 12/16/98 Sb-124 -1.17E+00 1.92E+00 7.47E+00 TM 15 46234 12/16/98 Se-75 1.48E+00 1.10E+00 3.47E+00 TM 15 46234 12/16/98 Th-232 -1.47E+00 3.76E+00 1.28E+01 TM 15 46234 12/16/98 Zn-65 1.46E+00 2.47E+00 8.25E+00 TM 15 46234 12/16/98 Zr-95 -0.62E+00 1.55E+00 5.27E+00 l
l l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
r- 1 l l 1 1 I Seabrook Nuclear Power Station ) Radiological Environmental Monitoring Program f Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 16 40356 01/14/98 Ag-110M 4.68E+00 2.05E+00 5.72E+00 TM 16 40356 '01/14/98 Ba-140 -1.16E+00 2.63E+00 1.09E+01 TM .6 40356 01/14/98 Be-7 -1.02E+01 1.37E+01 5.05E+01 TM 16 40356 01/14/98 Ce-141 5.28E+00 2.63E+00 7.73E+00 TM 16 40356 01/14/98 Ce-144 -7.20E+00 8.52E+00 2.79E+01 TM 16 40356 01/14/98 Co-57 0.21E+00 1.14E+00 3.58E+00 TM 16 40356 01/14/98 Co-58 0.76E+00 1.71E+00 5.83E+00 Th 16 40356 01/14/98 Co-60 2.44E+00 1.78E+00 5.78E+00 TM 16 40356 01/14/98 Cr-51 4.38E+00 1.48E+01 5.03E+01 TM 16 40356 01/14/98 Cs-134 -1.87E+00 1.42E+00 5.49E+00 TM 16 40356 01/14/98 Cs-137 1.13E+01 2.95E+00 9.86E+00
- TM 16 40356 01/14/98 Fe-59 -4.42E+00 5.21E+00 2.10E+01 TM 16 40356 01/14/98 I-131 -3.10E-02 3.31E-02 0.22E+00 TM 16 40356 01/14/98 K-40 1.82E+03 9.07E+01 1.06E+02
- TM 16 40356 01/14/98 Mn-54 -0.21E+00 1.61E+00 5.72E+00 TM 16 40356 01/14/98 Ru-103 -0.71E+00 1.68E+00 6.12E+00 TM 16 40356 01/14/98 Ru-106 1.15E+01 1.41E+01 4.95E+01 TM 16 40356 01/14/98 Sb-124 -5.31E+00 2.70E+00 1.45E+01 TM 16 40356 01/14/98 Se-75 -1.38E+00 2.08E+00 7.27E+00 TM 16 40356 01/14/98 Th-232 -1.07E+00 6.65E+00 2.37E+01 TM 16 40356 01/14/98 Zn-65 0.36E+00 4.87E+00 1.73E+01 TM 16 40356 01/14/98 Zr-95 -0.39E+00 3.27E+00 1.23E+01 TM 16 40876 02/11/98 Ag-110M -2.42E+00 2.24E+00 8.54E+00 1
TM 16 40876 02/11/98 Ba-140 -0.79E+00 1.96E+00 8.34E+00 TM 16 40876 02/11/98 Be-7 1.83E+01 1.12E+01 3.48E+01 TM 16 40876 02/11/98 Ce-141 -4.29E+00 2.40E+00 8.12E+0C TM 16 40876 02/11/98 Ce-144 -0.23E+00 9.32E+00 2.94E+01 TM 16 40876 02/11/98 Co-57 -1.19E+00 1.05E+00 3.48E+00 TM 16 40876 02/11/98 Co-58 4.33E+00 1.76E+00 4.90E+00 TM 16 40876 02/11/98 Co-60 -1.95E+00 1.92E+00 7.81E+00 TM 16 40876 02/11/98 Cr-51 6.38E+00 1.32E+01 4.44E+01 TM 16 40876 02/11/98 Cs-134 0.86E+00 1.38E+00 4.69E+00 TM 16 40876 02/11/98 Cs-137 1.59E+00 1.67E+00 5.80E+00 TM 16 40876 02/11/98 Fe-59 -6.86E+00 5.13E+00 2.12E+01 TM 16 40876 02/11/98 I-131 -9.02E-02 6.44E-02 0.40E+00 TM 16 40876 02/11/98 K-40 1.70E+03 8.73E+01 1.07E+02
- TM 16 40876 02/11/98 Mn-54 0.42E+00 1.53E+00 5.30E+00 TM 16 40876 02/11/98 Ru-103 -3.29E+00 1.66E+00 6.54E+00 TM 16 40876 02/11/98 Ru-106 -6.67E+00 1.62E+01 6.07E+01 TM 16 40876 02/11/98 Sb-124 5.93E+00 4.32E+00 1.38E+01 TM 16 40876 02/11/98 Se-75 1.14E+00 1.97E+00 6.51E+00 TM 16 40876 02/11/98 Th-232 -3.46E+00 6.09E+00 2.26E+01 TM 16 40876 02/11/98 Zn-65 -0.44E+00 3.86E+00 1.43E+01 TM 16 40876 02/11/98 Zr-95 -2.00E+00 2.83E+00 1.13E+01 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
t
Seabrook Nuclear Power Station Radiolcgical Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 16 41334 03/11/98 Ag-110M 0.27E+00 1.67E+00 5.74E+00 TM 16 41334 03/11/98 Ba-140 -0.17E+00 1.77E+00 6.68E+00 TM 16 41334 03/11/98 Be-7 -0.67E+00 1.03E+01 3.62E+01 TM 16 41334 03/11/98 Ce-141 2.84E+00 2.06E+00 6.21E+00 TM 16 41334 03/11/98 Co-144 -1.19E+01 7.80E+00 2.60E+01 TM 16 41334 03/11/98 Co-57 2.68E-02 1.04E+00 3.29E+00 TM 16 41334 03/11/98 Co-58 0.49E+00 1.20E+00 4.05E+00 TM 16 41334 03/11/98 Co-60 3.59E+00 1.43E+00 4.05E+00 TM 16 41334 03/11/98 Cr-51 0.40E+00 1.06E+01 3.63E+01 TM 16 41334 03/11/98 Cs-134 -0.31E+00 1.24E+00 4.25E+00 TM 16 41334 03/11/98 Cs-137 3.14E+00 1.66E+00 5.68E+00 TM 16 41334 03/11/98 Fe-59 -2.72E+00 3.82E+00 1.47E+01 TM 16 41334 03/11/98 I-131 3.96E-03 3.46E-02 0.18E+00 TM 16 41334 03/11/98 K-40 1.89E+03 7.26E+01 7.87E+01
- TM 16 41334 03/11/98 Mn-54 -4.71E-02 1.20E+00 4.17E+00 TM 16 41334 03/11/98 Ru-103 -3.00E+00 1.31E+00 5.13E+00 TM 16 41334 03/11/98 Ru-106 -9.37E+00 1.17E+01 4.47E+01 TM 16 41334 03/11/98 Sb-124 -0.57E+00 2.11E+00 8.66E+00 TM 16 41334 03/11/98 Se-75 -0.12E+00 1.58E+00 5.37E+00 TM 16 41334 03/11/98 Th-232 -3.37E+00 4.67E+00 1.72E+01 TM 16 41334 03/11/98 Zn-65 1.31E+00 3.34E+00 1.16E+01 TM 16 41334 03/11/98 Zr-95 -1.14E+00 2.25E+00 8.60E+00 TM 16 41606 04/08/98 Ag-110M 0.45E+00 1.41E+00 4.78E+00 TM 16 41606 04/08/98 Ba-140 0.89E+00 0.90E+00 3.14E+00 TM 16 41606 04/08/98 Be-7 0.37E+00 8.54E+00 2.97E+01 TM 16 41606 04/08/98 Ce-141 1.36E+00 1.85E+00 5.72E+00 TM 16 41606 04/08/98 Ce-144 1.39E+00 6.91E+00 2.16E+01 TM 16 41606 04/08/98 Co-57 1.52E+00 0.96E+00 2.85E+00 TM 16 41606 04/08/98 Co-58 -0.45E+00 1.05E+00 3.74E+00 TM 16 41606 04/08/98 Co-60 -0.90E+00 1.09E+00 4.32E+00 TM 16 41606 04/08/98 Cr-51 -1.28E+01 1.08E+01 3.85E+01 TM 16 41606 04/08/98 Cs-134 0.13E+00 1.04E+00 3.74E+00 TM 16 41606 04/08/98 Cs-137 3.54E+00 1.70E+00 5.66E+00 TM 16 41606 04/08/98 Fe-59 -0.34E+00 3.63E+00 1.31E+01 TM 16 41606 04/08/98 I-131 7.03E-02 6.73E-02 0.30E+00 TM 16 41606 04/08/98 K-40 1.66E+03 6.14E+01 5.74E+01
- l TM 16 41606 04/08/98 Mn-54 -0.16E+00 1.07E+00 3.71E+00 TM 16 41606 04/08/98 Ru-103 -1.72E+00 'O.98E+00 3.81E+00 TM 16 41606 04/08/98 Ru-106 -1.69E+01 9.29E+00 3.78E+01 TM 16 41606 04/08/98 Sb-124 1.26E+00 2.27E+00 8.07E+00 TM 16 41606 04/08/98 Se-75 1.54E+00 1.40E+00 4.50E+00 TM 16 41606 04/08/98 Th-232 4.14E+00 4.14E+00 1.33E+01 TM 16 41606 04/08/98 Zn-65 -0.81E+00 2.99E+00 1.07E+01 TM 16 41606 04/08/98 Zr-95 0.00E+00 2.17E+00 7.89E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 16 41905 04/22/98 Ag-110M -0.29E+00 2.64E+00 9.12E+00 TM 16 41905 04/22/98 Ba-140 5.58E+00 3.00E+00 8.90E+00 I TM 16 41905 04/22/98 Be-7 5.09E+00 1.48E+01 5.01E+01 TM 16 41905 04/22/98 Ce-141 0.76E+00 2.45E+00 7.57E+00 TM 16 41905 04/22/98 Ce-144 -3.79E+00 8.64E+00 2.74E+01 l TM 16 41905 04/22/98 Co-57 -0.53E+00 1.11E+00 3.52E+00 l TM 16 41905 04/22/98 Co-58 0.41E+00 1.87E+00 6.35E+00 ! TM 16 41905 04/22/98 Co-60 -0.24E+00 2.15E+00 7.95E+00 ! TM 16 41905 04/22/98 Cr-51 -1.02E+01 1.50E+01 5.23E+01 TM 16 41905 04/22/98 Cs-134 -1.62E+00 1.70E+00 6.15E+00 TM 16 41905 04/22/98 Cs-137 4.90E+00 2.69E+00 8.99E+00 TM 16 41905 04/22/98 Fe-59 -7.71E+00 6.12E+00 2.41E+01 TM 16 41905 04/22/98 I-131 7.70E-02 7.23E-02 0.32E+00 TM 16 41905 04/22/98 K-40 1.79E+03 9.05E+01 1.27E+02
- TM 16 41905 04/22/98 Hn-54 -0.13E+00 1.63E+00 5.71E+00 16 Ru-103 {
TM 41905 04/22/98 1.15E+00 1.71E+00 5.73E+00 l TM 16 41905 04/22/98 Ru-106 2.25E+01 1.55E+01 5.11E+01 TM 16 41905 04/22/98 Sb-124 1.96E+00 4.19E+00 1.51E+01 TM 16 41905 04/22/98 Se-75 -0.53E+00 1.98E+00 6.73E+00 TM 16 41905 04/22/98 Th-232 5.74E+00 7.63E+00 2.52E+01 TM 16 41905 04/22/98 Zn-65 -8.71E+00 4.86E+00 1.91E+01 TM 16 41905 04/22/98 Zr-95 3.76E+00 3.64E+00 1.24E+01 TM 16 42156 05/06/98 Ag-110M -0.60E+00 1.80E+00 6.37E+00 TM 16 42156 05/06/98 Ba-140 0.40E+00 2.94E+00 1.08E+01 TM 16 42156 05/06/98 Be-7 -2.13E+01 1.14E+01 4.41E+01 TM 16 42156 05/06/98 Ce-141 0.53E+00 2.73E+00 8.58E+00 TM 16 42156 05/06/98 Ce-144 4.49E+00 8.45E+00 2.61E+01 TM 16 42156 05/06/98 Co-57 0.25E+00 1.03E+00 3.22E+00 TM 16 42156 05/06/98 Co-58 0.27E+00 1.35E+00 4.63E+00 l TM 16 42156 05/06/98 Co-60 0.19E+00 1.25E+00 4.62E+00 TM 16 42156 05/06/98 Cr-51 1.13E+01 1.46E+01 4.80E+01 TM 16 42156 05/06/98 Cs-134 3.85E-02 1.13E+00 3.85E+00 TM 16 42156 05/06/98 Cs-137 4.07E+00 1.57E+00 4.81E+00 TM 16 42156 05/06/98 Fe-59 -4.07E+00 4.08E+00 1.62E+01 TM 16 42156 05/06/98 I-131 6.69E-02 7.00E-02 0.32E+00 TM 16 42156 05/06/98 K-40 1.86E+03 7.07E+01 6.07E+01
- TM 16 42156 05/06/98 Mn-54 0.43E+00 1.22E+00 4.13E+00 TM 16 42156 05/06/98 Ru-103 0.26E+00 1.51E+00 5.22E+00 TM 16 42156 05/06/98 Ru-106 -3.18E+00 1.12E+01 4.20E+01 TM 16 42156 05/06/98 Sb-124 -0.75E+00 2.75E+00 1.09E+01 TM 16 42156 05/06/98 Se-75 0.34E+00 1.81E+00 6.06E+00 TM 16 42156 05/06/98 Th-232 0.18E+00 4.65E+00 1.63E+01 TM 16 42156 05/06/98 Zn-65 4.07E+00 3.47E+00 1.08E+01 TM 16 42156 05/06/98 Zr-95 0.75E+00 2.49E+00 9.03E+00 1
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pC1/kg) (pCi/kg) TM 16 42281 05/20/98 Ag-110M 1.46E+00 2.67E+00 9.21E+00 TM 16 42281 05/20/98 Ba-140 0.57E+00 2.11E+00 8.70E+00 TM 16 42281 05/20/98 Be-7 -2.68E+01 1.60E+01 6.41E+01 TM 16 42281 05/20/98 Ce-141 8.99E-02 2.97E+00 9.47E+00 TM 16 42281 05/20/98 Ce-144 9.78E+00 1.13E+01 3.47E+01 TM 16 42281 05/20/98 Co-57 -2.10E+00 1.31E+00 4.48E+00 TM 16 42281 05/20/98 Co-58 -1.89E+00 2.08E+00 8.02E+00 TM 16 42281 05/20/98 Co-60 1.75E+00 2.40E+00 8.74E+00 TM 16 42281 05/20/98 Cr-51 2.65E+00 1.73E+01 5.98E+01 TM 16 42281 05/20/98 Cs-134 0.00E+00 1.83E+00 6.87E+00 TM 16 42281 05/20/98 Cs-137 4.61E+00 2.31E+00 7.19E+00 TM 16 42281 05/20/98 Fe-59 6.68E+00 '7.30E+00 2.50E+01 TM 16 42281 05/20/98 I-131 2.78E-02 6.49E-02 0.37E+00 TM 16 42281 05/20/98 K-40 1.89E+03 1.08E+02 9.45E+01
- TM 16 42281 05/20/98 Mn-54 0.60E+00 1.80E+00 6.35E+00 TM 16 42281 05/20/98 Ru-103 -0 '9E+00 1.67E+00 6.28E+00 TM 16 42281 05/20/98 Ru-106 1.29E+01 1.76E+01 6.28E+01 TM 16 42281 05/20/98 Sb-124 -2.69E+00 2.93E+00 1.57E+01 TM 16 42281 05/20/98 Se-75 -4.33E+00 2.31E+00 8.76E+00 TM 16 42281 05/20/98 Th-232 6.13E+00 6.94E+00 2.37E+01 TM 16 42281 05/20/98 Zn-65 5.80E+00 5.59E+00 1.88E+01 TM 16 42281 05/20/98 Zr-95 -4.68E+00 3.27E+00 1.34E+01 TM 16 42588 06/03/98 Ag-110M 2.53E+00 1.54E+00 4.70E+00 TM 16 42588 06/03/98 Ba-140 -1.68E+00 2.05E+00 7.85E+00 TM 16 42588 06/03/98 Be-7 -9.61E+00 8.66E+00 3.0BE+01 TM 16 42588 06/03/98 Ce-141 -0.79E+00 1.77E+00 5.55E+00 TM 16 42588 06/03/98 Ce-144 -5.97E+00 5.84E+00 1.84E+01 TM 16 42588 06/03/98 Co-57 -9.92E-02 0.76E+00 2.36E+00 TM 16 42588 06/03/98 Co-58 1.71E+00 1.27E+00 3.94E+00 TM 16 42588 06/03/98 Co-60 1.20E+00 1.17E+00 3.87E+00 TM 16 42588 06/03/98 Cr-51 2.39E+00 1.04E+01 3.42E+01 TM 16 42588 06/03/98 Cs-134 0.49E+00 0.81E+00 2.51E+00 TM 16 42588 06/03/98 Cs-137 5.88E+00 2.07E+00 7.27E+00 TM 16 42588 06/03/98 Fe-59 -1.16E+00 3.88E+00 1.38E+01 TM 16 42588 06/03/98 I-131 0.21E+00 0.11E+00 0.37E+00 TM 16 42588 06/03/98 K-40 1.84E+03 5.77E+01 6.25E+01
- TM 16 42588 06/03/98 Mn-54 -2.89E-02 1.02E+00 3.42E+00 TM 16 42588 06/03/98 Ru-103 -0.50E+00 1.16E+00 3.99E+00 TM 16 42588 06/03/98 Ru-106 -1.85E+00 9.78E+00 3.50E+01 TM 16 42588 06/03/98 Sb-124 2.79E+00 2.46E+00 8.01E+00 TM 16 42588 06/03/98 Se-75 0.19E+00 1.31E+00 4.31E+00 TM 16 42588 06/03/98 Th-232 5.97E+00 4.51E+00 1.43E+01 TM 16 42588 06/03/98 Zn-65 -2.92E+00 3.01E+00 1.08E+01 TM 16 42588 06/03/98 Zr-95 -1.53E+00 2.00E+00 7.43E+00
- Radioactivity detected in sample (i.e. , CONC > 3 STD. DEV. )
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) ____.___________________________________________________________________________ i TM 16 42692 06/17/98 Ag-110M -0.25E+00 2.18E+00 8.06E+00 TM 16 42692 06/17/98 Ba-140 -2.91E+00 2.21E+00 9.85E*00 TM 16 42692 06/17/98 Be-7 1.02E+01 1.29E+01 4.34E+01 TM 16 42692 06/17/98 Ce-141 1.19E+00 2.79E+00 8.88E+00 , TM 16 42692 06/17/98- Ce-144 -1.52E+00 9.98E+00 3.20E+01 l TM 16 42692 06/17/98 Co-57 2.38E+00 1.32E+00 3.89E+00 TM 16 42692 06/17/98 Co-58 1.08E+00 1.54E+00 5.15E+00 TM 16 42692 06/17/98 Co-60 2.08E+00 1.54E+00 4.91E+00 TM 16 42692 06/17/98 Cr-51 -0.88E+00 1.36E+01 4.75E+01 TM 16 42692 06/17/98 Cs-134 -0.72E+00 1.27E+00 4.65E+00 TM 16 42692 06/17/98 Cs-137 2.97E+00 2.11E+00 7.01E+00 TM 16 42692 06/17/98 Fe-59 -2,29E+00 4.62E+00 1.76E+01 TM 16 42692 06/17/98 I-131 0.14E+00 8.64E-02 0.34E+00 TM 16 42692 06/17/98 K-40 1.77E+03 8.34E+01 7.78E+01
- TM 16 42692 06/17/98 Mn-54 2.33E+00 1.68E+00 5.22E+00 TM 16 42692 06/17/98 Ru-103 0.33E+00 1.55E+00 5.47E+00 TM 16 42692 06/17/J8 Ru-106 -1.61E+00 1.62E+01 6.00E+01 TM 16 42692 06/17/98 Sb-124 1.56E+00 4.09E+00 1.51E+01 TM 16 42692 06/17/98 Se-75 1.28E+00 2.26E+00 7.47E+00 TM 16 42692 06/17/98 Th-232 -3.09E+00 6.71E+00 2.50E+01 TM 16 42692 06/17/98 Zn-65 0.83E+00 3.67E+00 1.32E+01 TM 16 42692 06/17/98 Zr-95 -0.37E+00 2.57E+00 9.29E+00 TM 16 42918 07/01/98 Ag-110M -2.26E+00 2.32E+00 8.94E+00 TM 16 42918 07/01/98 Ba-140 -1.01E+00 2.51E+00 1.11E+01 TM 16 42918 07/01/98 Be-7 -1.10E+00 1.24E+01 4.51E+01 TM 16 42918 07/01/98 Ce-141 -0.87E+00 2.71E+00 8.82E+00 TM 16 42918 07/01/98 Ce-144 -1.58E+01 8.88E+00 3.03E+01 TM 16 42918 07/01/98 Co-57 -0.23E+00 1.05E+00 3.39E+00 TM 16 42918 07/01/98 Co-58 2.29E+00 1.75E+00 5.50E+00 TM 16 42918 07/01/98 Co-60 0.44E+00 2.21E+00 8.33E+00 TM 16 42918 07/01/98 Cr-51 -2.19E+01 1.73E+01 6.35E+01 TM 16 42918 07/01/98 Cs-134 1.44E+00 1.50E+00 4.51E+00 TM 16 42918 07/01/98 Cs-137 5.55E+00 2.63E+00 8.97E+00 TM 16 42918 07/01/98 Fe-59 5.89E+00 6.53E+00 2.22E+01 TM 16 42918 07/01/98 I-131 -4.48E-02 3.25E-02 0.29E+00 TM 16 42918 07/01/98 K-40 1.71E+03 9.08E+01 9.66E+01
- TM 16 42918 07/01/98 Mn-54 -1.01E+00 1.26E+00 5.03E+00 TM 16 42918 07/01/98 Ru-103 -9.49E-02 1.86E+00 6.61E+00 TM 16 42918 07/01/98 Ru-106 1.73E+01 1.47E+01 4.98E+01 TM 16 42918 07/01/98 Sb-124 1.03E+00 3.81E+00 1.51E+01 TM 16 42918 07/01/98 Se-75 -3.31E+00 2.00E+00 7.41E+00 TM 16 42918 07/01/98 Th-232 '3.49E+00 6.59E+00 2.27E+01 TM 16 42918 07/01/98 Zn-65 -0.98E+00 4.61E+00 1.70E+01 TM 16 42918 07/01/98 Zr-95 2.19E+00 3.13E+00 1.05E+01 l
l l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. IOC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 16 43154 07/22/98 Ag-110M 0.50E+00 1.67E+00 5.82E+00 TM 16 43154 07/22/98 Ba-140 -1.56E+00 2.01E+00 8.36E+00 TM 16 43154 07/22/98 Be-7 -0.79E+00 1.30E+01 4.52E+01 TM 16 43154 07/22/98 Ce-141 -0.58E+00 2.28E+00 7.34E+00 TM 16 43154 07/22/98 Ce-144 2.61E+00 8.45E+00 2.63E+01 TM 16 43154 07/22/98 Co-57 1.51E+00 1.09E+00 3.27E+00 TM 16 43154 07/22/98 Co-58 -2.05E+00 1.45E+00 5.57E+00 TM 16 43154 07/22/98 Co-60 -0.46E+00 1.64E+00 6.25E+00 TM 16 43154 07/22/98 Cr-51 -1.36E+01 1.33E+01 4.76E+01 TM 16 43154 07/22/98 Cs-134 -1.49E+00 1.26E+00 4.63E+00 TM 16 43154 07/23/98 Cs-137 1.19E+01 2.43E+00 7.21E+00 * ' TM 16 43154 07/22/98 Fe-59 3.05E+00 5.20E+00 1.80E+01 TM 16 43154 07/22/98 I-131 -2.56E-02 5.48E-02 0.45E+00 TM 16 43154 07/22/98 K-40 1.86E+03 8.10E+01 8.52E+01
- TM 16 43154 07/22/98 Mn-54 -0.86E+00 1.24E+00 4.62E+00 TM 16 43154 07/22/98 Ru-103 -1.98E+00 1.33E+00 5.15E+00 TM 16 43154 07/22/98 Ru-106 6.75E+00 1.15E+01 4.10E+01 TM 16 43154 07/22/98 Sb-124 2.12E+00 3.12E+00 1.11E+01 TM 16 43154 07/22/98 Se-75 -0.89E+00 1.76E+00 6.09E+00 TM 16 43154 07/22/98 Th-232 0.43E+00 6.01E+00 2.08E+01 TM 16 43154 07/22/98 Zn-65 -3.92E+00 3.92E+00 1.49E+01 TM 16 43154 07/22/98 Zr-95 2.39E+00 2.49E+00 8.08E+00 TM 16 43393 08/05/98 Ag-110M 2.03E+00 2.14E+00 6.86E+00 TM 16 43393 08/05/98 Ba-140 0.19E+00 2.03E+00 7.52E+00 TM 16 43193 08/05/98 Be-7 -1.33E+01 1.06E+01 3.94E+01 TM 16 43393 08/05/98 Ce-141 2.75E+00 2.01E+00 6.00E+00 TM 16 43393 08/05/98 Ce-144 3.72E+00 7.60E+00 2.34E+01 TM 16 43393 08/05/98 Co-57 -4.27E-02 0.99E+00 3.08E+00 TM 16 43393 08/05/98 Co-58 -0.21E+00 1.34E+00 4.70E+00 TM 16 43393 08/05/98 Co-60 1.73E+00 1.64E+00 5.48E+00 TM 16 43393 08/05/98 Cr-51 1.82E+01 1.18E+01 3.72E+01 TM 16 43393 08/05/98 Cs-134 1.51E+00 1.18E+00 3.34E+00 TM 16 43393 08/05/98 Cs-137 1.18E+01 2.48E+00 7.38E+00
- TM 16 43393 08/05/98 Fe-59 -1.30E+00 4.74E+00 1.74E+01 TM 16 43393 08/05/98 I-131 1.54E-02 6.41E-02 0.38E+00 TM 16 43393 08/05/98 K-40 1.77E+03 7.61E+01 9.69E+01
- TM 16 43393 08/05/98 Mn-54 0.20E+00 1.31E+00 4.49E+00 TM 16 43393 08/05/98 Ru-103 -2.18E+00 1.40E+00 5.23E+00 TM 16 43393 08/05/98 Ru-106 1.03E+01 1.29E+01 4.48E+01 TM 16 43393 08/05/98 Sb-124 1.49E+00 2.82E+00 1.02E+01 TM 16 43393 08/05/98 Se-75 0.62E+00 1.76E+00 5.80E+00 TM 16 43393 08/05/98 Th-232 0.95E+00 5.45E+00 1.88E+01 TM 16 43393 08/05/98 Zn-65 -3.14E+00 3.76E+00 1.40E+01 TM 16 43393 08/05/98 Zr-95 4.31E+00 2.59E+00 8.44E+00 .
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE. NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 16 43690 08/19/98 Ag-110M 0.91E+00 1.90E+00 6.34E+00 TM 16 43690 08/19/98 Ba-140 0.13E+00 1.55E+00 6.16E+00 TM 16 43690 08/19/98 Be-7 -1.13E+00 1.09E+01 3.80E+01 TM 16 43690 08/19/98 Ce-141 5.11E+00 2.40E+00 6.97E+00 TM 16 43690 08/19/98 Ce-144 1.22E+01 8.18E+00 2.43E+01 TM 16 43690 08/19/98 Co-57 -0.69E+00 1.06E+00 3.36E+00 TM 16 43690 08/19/98 Co-58 0.10E+00 1.54E+00 5.21E+00 TM 16 43690 08/19/98 Co-60 -0.58E+00 1.29E+00 5.01E+00 TM 16 43690 08/19/98 Cr-51 -1.77E+01 1.38E+01 4.88E+01 TM 16 43690 08/19/98 Cs-134 1.77E+00 1.25E+00 3.86E+00 TM 16 43690 08/19/98 Cs-137 7.90E+00 2.21E+00 7.11E+00
- TM 16 43690 08/19/98 Fe-59 2.09E+00 4.63E+00 1.62E+01 TM 16 43690 08/19/98 I-131 9.88E-02 7.02E-02 0.28E+00 TM 16 43690. 08/19/98 K-40 1.93E+03 7.66E+01 9.33E+01
- TM 16 43690 08/19/98 Mn-54 0.24E+00 1.36E+00 4.60E+00 TM 16 43690 08/19/98 Ru-103 -3.76E+00 1.36E+00 5.41E+00 TM 16 43690 08/19/98 Ru-106 0.00E+00 1.28E+01 4.63E+01 i TM 16 43690 08/19/98 Sb-124 -0.91E+00 2.59E+00 1.05E+01 TM 16 43690 08/19/98 Se-75 -1.53E+00 1.86E+00 6.38E+00 TM 16 43690 08/19/98 Th-232 2.90E+00 5.16E+00 1.73E+01 TM 16 43690 08/19/98 Zn-65 -0.46E+00 3.55E+00 1.27E+01 TM 16 43690 08/19/98 Zr-95 3.81E+00 2.55E+00 7.85E+00 TM 16 43978 09/02/98 Ag-110M -1.12E+00 2.31E+00 8.56E+00 TM 16 43978 09/02/98 Ba-140 0.91E+00 2.59E+00 9.98E+00 TM 16 43978 09/02/98 Be-7 -6.44E+00 1.41E+01 5.14E+01 TM 16 43978 09/02/98 Ce-141 5.89E+00 2.58E+00 7.39E+00 TM 16 43978 09/02/98 Ce-144 1.57E+00 8.91E+00 2.81E+01 TM 16 43978 09/02/98 Co-57 1.21E+00 1.28E+00 3.89E+00 TM 16 43978 09/02/98 Co-58 1.66E+00 1.86E+00 6.10E+00 TM 16 43978 09/02/98 Co-60 3.98E+00 2.03E+00 6.24E+00 TM 16 43978 09/02/98 Cr-51 5.77E+00 1.68E+01 5.68E+01 TM 16 43978 09/02/98 Cs-134 0.54E+00 1.42E+00 4.82E+00 TM 16 43978 09/02/98 Cs-137 1.14E+01 3.21E+00 1.07E+01
- TM 16 43978 09/02/98 Fe-59 6.19E+00 6.29E+00 2.13E+01 TM 16 43978 09/02/98 I-131 6.27E-03 5.52E-02 0.30E+00 TM 16 43978 09/02/98 K-40 2.02E+03 9.79E+01 9.62E+01
- TM 16 43978 09/02/98 Mn-54 -0.31E+00 1.55E+00 5.65E+00 TM 16 43978 09/02/98 Ru-103 2.47E-02 1.90E+00 6.69E+00 TM 16 43978 09/02/98 Ru-106 -2.47E+01 1.60E+01 6.52E+01 TM 16 43978 09/02/98 Sb-124 0.91E+00 3.74E+00 1.49E+01 TM 16 43978 09/02/98 Se-75 -2.19E+00 2.04E+00 7.33E+00 TM 16 43978 09/02/98 Th-232 -8.73E+00 6.85E+00 2.65E+01 TM 16 43978 09/02/9C Zn-65 1.94E+00 4.62E+00 1.62E+01 TM 16 43978 09/02/98 Zr-95 1.45E+00 2.72E+00 9.37E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 16 44366 09/23/98 Ag-110M 1.67E+00 1.71E+00 5.58E+00 TM 16 44366 09/23/98 Ba-140 -1.96E+00 2.24E+00 9.39E+00 TM 16 44366 09/23/98 Be-7 8.91E+00 1.19E+01 3.98E+01 TM 16 44366 09/23/98 Ce-141 -1.74E+00 2.23E+00 7.19E+00 TM 16 44366 09/23/98 Ce-144 1.08E+01 8.21E+00 2.46E+01 TM 16 44366 09/23/98 Co-57 -0.59E+00 1.02E+00 3.27E+00 TM 16 44366 09/23/98 Co-58 -2.51E+00 1.35E+00 5.42E+00 TM 16 44366 09/23/98 Co-60 -3.65E+00 1.66E+00 7.44E+00 TM 16 44366 09/23/98 Cr-51 1.40E+01 1.27E+01 4.10E+01 l TM 16 44366 09/23/98 Cs-134 1.34E+00 1.16E+00 3.67E+00 ) TM 16 44366 09/23/98 Cs-137 6.57E+00 2.85E+00 9.79E+00 j TM 16 44366 09/23/98 Fe-59 -0.11E+00 5.37E+00 1.95E+01 TM 16 44366 09/23/98 I-131 3.53E-02 6.83E-02 0.35E+00 TM 16 44366 09/23/98 K-40 2.00E+03 8.45E+01 8.23E+01
- l TM 16 44366 09/23/98 Mn-54 0.52E+00 1.46E+00 4.96E+00 I TM 16 44366 09/23/98 Ru-103 -2.93E+00 1.45E+00 5.67E+00 I TM 16 44366 09/23/98 Ru-106 -2.40E+01 1.37E+01 5.50E+01 TM 16 44366 09/23/98 Sb-124 -0.44E+00 3.65E+00 1.44E+01 TM 16 44366 09/23/98 Se-75 2.51E+00 1.90E+00 6.05E+00 TM 16 44366 09/23/98 Th-232 -4.90E+00 5.79E+00 2.14E+01 '
TM 16 44366 09/23/98 Zn-65 -2.17E+00 4.68E+00 1.69E+01 i TM 16 44366 09/23/98 Zr-95 -0.84E+00 2.48E+00 8.91E+00 l l TM 16 45111 10/14/98 Ag-110M -6.52E-02 1.20E+00 4.18E+00 TM 16 Ba-140 1.48E+00
)
45111 10/14/98 -1.41E+00 5.74E+00 i TM 16 45111 10/14/98 Be-7 -4.74E+00 7.46E+00 2.59E+01 l TM 16 45111 10/14/98 Ce-141 -3.46E+00 1.70E+00 5.57E+00 ! TM 16 45111 10/14/98 Ce-144 0.50E+00 5.43E+00 1.68E+01 l TM 16 45111 10/14/98 Co-57 -0.75E+00 0.6;9E+00 2.20E+00 t TM 16 45111 10/14/98 Co-58 -0.54E+00 0.82E+00 2.86E+00 1 TM 16 45111 .10/14/98 Co-60 1.09E+00 0.99E+00 3.19E+00 TM 16 45111 10/14/98 Cr-51 -2.66E+00 8.72E+00 2.94E+01 TM 16 45111 10/14/98 Cs-134 0.51E+00 0.87E+00 2.99E+00 TM 16 45111 10/14/98 Cs-137 6.01E+00 1.41E+00 4.83E+00
- TM 16 45111 10/14/98 Fe-59 -1.86E+00 2.61E+00 9.36E+00 TM 16 45111 10/14/98 I-131 3.94E-02 8.12E-02 0.43E+00 TM 16 45111 10/14/98 K-40 1.81E+03 4.85E+01 4.66E+01
- TM 16 45111 10/14/98 Mn-54 -1.24E+00 0.77E+00 2.79E+00 TM 16 45111 10/14/98 Ru-103 -0.19E+00 0.95E+00 3.26E+00 j TM 16 45111 10/14/98 Ru-106 0.00E+00 7.81E+00 2.77E+01 TM 16 45111 10/14/98 Sb-124 -0.22E+00 1.80E+00 6.75E+00 TM 16 45111 10/14/98 Se-75 0.91E+00 1.15E+00 3.72E+00 TM 16 45111 10/14/98 Th-232 7.71E+00 3.45E+00 1.07E+01 TM 16 45111 10/14/98 Zn-65 -5.09E+00 2.24E+00 8.46E+00 1 TM 16 45111 10/14/98 Zr-95 -0.38E+00 1.52E+00 5.16E+00 f 1
- Radioactivity detected in sample (i.e., CONC > 3 STD, DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 16 45708 11/18/98 Ag-110M 0.93E+00 2.08E+00 7.08E+00 TM 16 45708 11/18/98 Ba-140 1.64E+00 2.26E+00 8.00E+00 TM 16 45708 11/18/98 Be-7 -1.29E+01 1.13E+01 4.30E+01 TM 16 45708 11/18/98 Ce-141 -4.08E+00 2.29E+00 7.74E+00 TM 16 45708 11/18/98 Ce-144 1.30E+00 8.36E+00 2.62E+01 TM 16 45708 11/18/98 Co-57 2.52E+00 1.20E+00 3.48E+00 TM 16 45708 11/18/98 Co-58 1.69E+00 1.57E+00 5.04E+00 TM 16 45708 11/18/98 Co-60 -1.84E+00 1.77E+00 7.40E+00 TM 16 45708 11/18/98 Cr-51 -2.66E+01 1.29E+01 4.91E+01 TM 16 45708 11/18/98 Cs-134 2.78E+00 1.70E+00 4.68E+00 TM 16 45708 11/18/98 Cs-137 1.36E+01 2.92E+00 8.94E+00
- TM 16 45708 11/18/98 Fe-59 -0.72E+00 5.14E+00 1.91E+01 TM 16 45708 11/18/98 I-131 -6.89E-02 5.62E-02 0.40E+00 TM 16 45708 11/18/98 K-40 1.77E+03 8.43E+01 8.86E+01
- TM 16 45708 11/18/98 Mn-54 6.39E-02 1.35E+00 4.78E+00 TM 16 45708 11/18/98 Ru-103 1.38E+00 1.62E+00 5.36E+00 TM 16 45708 11/18/98 Ru-106 8.68E+00 1.32E+01 4.67E+01 TM 16 45708 11/18/98 Sb-124 9.43E+00 3.85E+00 1.01E+01 TM 16 45708 11/18/98 Se-75 -3.18E+00 1.93E+00 6.98E+00 TM 16 45708 11/18/98 Th-232 -0.49E+00 6.01E+00 2.15E+01 TM 16 45708 11/18/98 Zn-65 5.14E+00 4.42E+00' 1.45E+01 TM 16 45708 11/18/98 Zr-95 -0.69E+00 2.85E+00 1.01E+01 TM 16 46235 12/16/98 Ag-110M 1.28E+00 1.35E+00 4.30E+00 TM 16 46235 12/16/98 Ba-140 -1.60E+00 1.27E+00 5.16E+00 TM 16 46235 12/16/98 Be-7 -2.39E+00 7.77E+00 2.65E+01 TM 16 46235 12/16/98 Ce-141 1.94E+00 1.56E+00 4.69E+00 TM 16 46235 12/16/98 Ce-144 1.00E+01 5.54E+00 1.63E+01 TM 16 46235 12/16/98 Co-57 0.58E+00 0.70E+00 2.10E+00 TM 16 46235 12/16/98 Co-58 -0.69E+00 1.04E+00 3.58E+00 TM 16 46235 12/16/98 Co-60 -0.41E+00 1.03E+00 3.76E+00 TM 16 46235 12/16/98 Cr-51 1.39E+00 8.75E+00 2.89E+01 TM 16 46235 12/16/98 Cs-134 0.60E+00 0.78E+00 2.36E+00 TM 16 46235 12/16/98 Cs-137 1.25E+01 1.81E+00 5.60E+00
- TM 16 46235 12/16/98 Fe-59 0.24E+00 3.57E+00 1.23E+01 TM 16 46235 12/16/98 I-131 -3.32E-02 5.98E-02 0.37E+00 TM 16 46235 12/16/98 K-40 1.76E+03 5.29E+01 5.78E+01
- TM 16 46235 12/16/98 Mn-54 0.30E+00 1.02E+00 3.33E+00 TM 16 46235 12/16/98 Ru-103 -1.68E+00 1.00E+00 3.60E+00 TM 16 46235 12/16/98 Ru-106 2.41E+00 8.97E+00 3.13E+01 TM 16 46235 12/16/98 Sb-124 -0.88E+00 2.02E+00 7.61E+00 TM 16 46235 12/16/98 Se-75 0.13E+00 1.26E+00 4.11E+00 TM 16 46235 12/16/98 Th-232 -0.29E+00 4.06E+00 1.36E+01 TM 16 46235 13/16/98 Zn-65 -2.37E+00 2.52E+00 8.56E+00 TM 16 ,
46235 12/16/98 Zr-95 -2.93E+00 1.97E+00 7.42E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 20 40357 01/14/98 Ag-110M -0.77E+00 1.30E+00 4.69E+00 TM 20 40357 01/14/98 Ba-140 1.15E+00 1.60E+00 5.54E+00 TM 20 40357 01/14/98 Be-7 1.49E+01 8.85E+00 2.77E+01 l TM 20 40357 01/14/98 Ce-141 0.49E+00 1.86E+00 5.79E+00 l TM 20 40357 01/14/98 Ce-144 -7.75E+00 5.99E+00 1.98E+01 l TM 20 40357 01/14/98 Co-57 -1.23E+00 0.87E+00 2.86E+00 TM 20 40357 01/14/98 Co-58 0.39E+00 0.93E+00 3.16E+00 , TM 20 40357 01/14/98 Co-60 0.53E+00 0.98E+00 3.45E+00 i TM 20 40357 01/14/98 Cr-51 2.17E+00 1.07E+01 3.58E+01 I TM 20 40357 01/14/98 Cs-134 -0.23E+00 0.92E+00 3.25E+00 TM 20 40357 01/14/98 Cs-137 1.95E+00 1.11E+00 3.62E+00 TM 20 40357 01/14/98 Fe-59 -0.72E+00 3.02E+00 1.12E+01 l TM 20 40357 01/14/98 I-131 -5.84E-02 2.43E-02 0.23E+00 l TM 20 40357 01/14/98 K-40 1.41E+03 5.39E+01 5.36E+01
- 1 TM 20 40357 01/14/98 Mn-54 -0.18E+00 1.01E+00 3.50E+00 )
TM 20 40357 01/14/98 Ru-103 -1.51E+00 1.06E+00 3.97E+00 TM 20 40357 01/14/98 Ru-106 9.91E+00 {
-4.74E+00 3.67E+01 TM 20 40357 01/14/98 Sb-124 -0.74E+00 2.21E+00 8.56E+00 TM 20 40357- 01/14/98 Se-75 -0.50E+00 1.36E+00 4.64E+00 TM 20 40357 01/14/98 Th-232 -2.93E+00 3.88E+00 1.41E+01 TM. 20 40357 01/14/98 Zn-65 -4.80E+00 2.82E+00 1.08E+01 TM. 20 40357 01/14/98 Zr-95 3.22E+00 1.67E+00 5.67E+00 TM 20 40877 02/12/98 Ag-110M 2.44E+00 1.47E+00 4.48E+00 !
TM 20 40877 02/12/98 Ba-140 1.48E+00 1.58E+00 5.34E+00 l TM 20 40877 02/12/98 Be-7 -4.04E+00 9.22E+00 3.30E+01 TM 20 40877 02/12/98 Ce-141 9.77E-02 1.89E+00 5.95E+00 l TM 20 40877 02/12/98 Ce-144 1.37E+01 7.26E+00 2.12E+01 TM 20 40877 02/12/98 Co-57 0.22E+00 0.91E+00 2.85E+00 TM 20 40877 02/12/98 Co-58 8.90E-02 1.12E+00 3.89E400 TM -20 40877 02/12/98 Co-60 -1.41E+00 1.30E+00 5.13E+00 TM 20 40877 02/12/98 Cr-51 -1.93E+01 9.97E+00 3.74E+01 TM 20 40877 02/12/98 Cs-134 0.76E+00 1.07E+00 3.49E+00 TM 20 40877 02/12/98 Cs-137 0.17E+00 1.24E+00 4.49E+00 TM 20 40877 02/12/98 Fe-59 5.2SE+00 4.04E+00 1.32E+01 TM 20 40877 02/12/98 I-131 0.00E+00 7.09E-02 0.44E+00 TM 20 40877 02/12/98 K-40 1.39E+03 5.91E+01 6.59E+01
- TM 20 40877 02/12/98 Mn-54 -1.49E+00 1.07E+00 4.06E+00 TM 20 40877 02/12/98 Ru-103 -1.16E+00 1.26E+00 4.57E+00 TM 20 40877 02/12/98 Ru-106 8.47E+00 1.06E+01 3.66E+01 TM 20 40877 02/12/98 Sb-124 1.95E+00 2.09E+00 7.19E+00 TM 20 40877 02/12/98 Se-75 1.67E+00 1.51E+00 4.87E+00 TM 20 40877 02/12/98 Th-232 -6.23E+00 4.56E+00 1.71E+01 TM 20 40877 02/12/98 Zn-65 0.***+00 2.77E+00 9.79E+00 TM 20 40877 02/12/98 Zr+95 -0.92E+00 2.17E+00 7.63E+00 f
I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 20 41335 03/11/98 Ag-110M 2.63E+00 1.46E+00 4.39E+00 TM 20 41335 03/11/98 Ba-140 1.24E+00 1.69E+00 5.82E+00 TM 20 41335 03/11/98 Be-7 -0.23E+00 9.97E+00 3.46E+01 TM 20 41335 03/11/98 Ce-141 1.19E+00 1.94E+00 5.96E+00 TM 20 41335 03/11/98 Ce-144 -1.70E+00 7.23E+00 2.30E+01 TM 20 41335 03/11/98 Co-57 1.41E+00 0.96E+00 2.87E+00 TM 20 41335 03/11/98 Co-58 -1.39E+00 1.15E+00 4.30E+00 TM 20 41335 03/11/98 Co-60 -0.66E+00 1.15E+00 4.50E+00 TM 20 41335 03/11/98 Cr-51 2.77E+00 1.10E+01 3.71E+01 TM 20 41335 03/11/98 Cs-134 0.83E+00 1.20E+00 3.77E+00 TM 20 41335 03/11/98 Cs-137 4.01E+00 1.36E+00 4.01E+00 TM 20 41335 03/11/98 Fe-59 3.37E+00 3.11E+00 1.04E+01 TM 20 41335 03/11/98 I-131 -1.14E-02 2.87E-02 0.18E+00 TM 20 41335 03/11/98 K-40 1.34E+03 5.81E+01 6.35E+01
- TM 20 41335 03/11/98 Mn-54 -0.72E+00 1.10E+00 3.97E+00 TM 20 41335 03/11/98 Ru-103 -0.69E+00 1.23E+00 4.42E+00 TM 20 41335 03/11/98 Ru-106 -1.13E+01 1.08E+01 4.16E+01 TM 20 41335 03/11/98 Sb-124 -3.07E+00 2.50E+00 1.05E+01 TM 20 41335 03/11/98 Se-75 1.51E+00 1.66E+00 5.38E+00 TM 20 41335 03/11/98 Th-232 -6.07E+00 4.14E+00 1.60E+01 TM 20 41335 03/11/98 Zn-65 -3.75E+00 2.66E+00 1.04E+01 TM 20 41335 03/11/98 Zr-95 -3.50E+00 1.83E+00 7.25E+00 TM 20 41607 04/08/98 Ag-110M 1.68E+00 1.39E+00 4.38E+00 TM 20 41607 04/08/98 Ba-140 -0.87E+00 1.12E+00 4.67E+00 TM. 20 41607 04/08/98 Be-7 -3.38E+00 7.06E+00 2.56E+01 TM 20 41607 04/08/98 Ce-141 -0.78E+00 1.64E+00 5.25E+00 TM 20 41607 04/08/98 Ce-144 2.98E+00 6.50E+00 2.01E+01 TM 20 41607 04/08/98 Co-57 -0.89E+00 0.81E+00 2.64E+00 TM 20 41607 04/08/98 Co-58 1.64E+00 1.08E+00 3.34E+00 TM 20 41607 04/08/98 Co-60 0.70E+00 0.96E+00 3.34E+00 TM 20 41607 04/08/98 Cr-51 -8.01E+00 9.60E+00 3 . 3 7E+'J1 TM 20 41607 04/08/98 Cs-134 -0.49E+00 0.83E+00 2.94F+00 TM 20 41607 04/08/98 Cs-137 1.95E+00 1.15E+00 3 . 7 /.E + 0 0 TM 20 41607 04/08/98 Fe-59 2.41E+00 2.68E+00 9.'.3E+00 TM 20 41607 04/08/98 I-131 -2.39E-02 2.85E-02 0 24E+00 TM 20 41607 04/08/98 K-40 1.22E+03 5.11E+01 f.09E+01
- TM 20 41607 04/08/98 Mn-54 -0.21E+00 0.93E+00 3.26E+00 TM 20 41607 04/08/98 Ru-103 -0.54E+00 1.12E+00 3.96E+00 TM 20 41607 04/08/98 Ru-106 4.70E+00 9.41E+00 3.32E+01 TM 20 41607 04/08/98 Sb-124 0.10E+00 2.35E+00 8.63E+00 TM 20 41607 04/08/98 Se-75 -0.64E+00 1.39E+00 4.76E+0.0 TM 20 41607 04/08/98 Th-232 4.53E+00 4.53E+00 1.46E+01 TM 20 41607 04/08/98 Zn-65 0.56E+00 2.40E+00 8.43E+00 TM 20 41607 04/08/98 Zr-95 -1.35E+00 1.74E+00 6.30E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l 1
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data v-SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 20 41906 04/22/98 Ag-110M 0.60E+00 1.80E+00 5.93E+00 TM 20 41906 04/22/98 Ba-140 -1.76E+00 2.09E+00 7.94E+00 TM 20 41906 04/22/98 Be-7 1.82E+01 1.04E+01 3.25E+01 TM 20 41906 04/22/98 Ce-141 -4.91E+00 1.85E+00 6.18E+00 TM 20 41906 04/22/98 Ce-144 7.94E+00 6.43E+00 1.92E+01 TM 20 41906 04/22/98 Co-57 0.78E+00 0.80E+00 2.40E+00 TM 20 41906 04/22/98 Co-58 0.62E+00 1.29E+00 4.22E+00 TM 20 41906 04/22/98 Co-60 -0.88E+00 1.48E+00 5 91E+00 TM 20 41906 04/22/98 Cr-51 -1.31E+01 1.15E+01 2.95E+01 TM 20 41906 04/22/98 Cs-134 -2.38E+00 1.19E+00 4.23E+00 TM 20 41906 04/22/98 Cs-137 2.33Es00 1.42E+00 4.66E+00 TM 20 41906 04/22/98 Fe-59 4.47E+00 4.72E+00 1.56E+01 TM 20 41906 04/22/98 Z-131 8.73E-02 6.45E-02 0.26E+00 TM 20 41906 04/22/98 K-40 1.20E+03 5.53E+01 9.03E+01
- TM 20 41906 04/22/98 Mn-54 3.43E-02 1.23E+00 4.11E+00 TM 20 41906 04/22/98 Ru-103 -2.39E+00 1.29E+00 4.68E+00 TM 20 41906 04/22/08 Ru-106 8.71E+00 1.19E+01 4.08E+01 TM 20 41906 04/22/98 Sb-124 -3.58E+00 2.89E+00 1.15E+01 TM 20 41906 04/22/98 Se-75 0.26E+00 1.59E+00 5.22E+00 TM 20 41906 04/22/98 Th-232 -1.04E+00 5.33E+00 1.82E+01 TM 20 41906 04/22/98 Zn-65 0.69E+00 3.37E+00 1.15E+01 TM 20 41906 04/22/98 Zr-95 4.80E+00 2.35E+00 7.00E+00 TM 20 42157 05/06/98 Ag-110M -0.68E+00 1.59E+00 5.85E+00 TM 20 42157 05/06/98 Ba-140 -1.00E+00 2.98E+00 1.15E+01 TM 20 42157 05/06/98 Be-7 7.66E+00 1.03E+01 3.49E+01 TM 20 42157 05/06/98 Ce-141 -1.20E+00 2.35E+00 7.64E+00 TM 20 42157 05/06/98 Ce-144 -4.84E+00 7.98E+00 2.60E+01 TM 20 42157 05/06/98 Co-57 0.51E+00 1.02E+00 3.19E+00 TM 20 42157 05/06/98 Co-58 -1.80E+00 0.99E+00 4.23E+00 TM 20 42157 .05/06/98 Co-60 -1.56E+00 1.40E+00 5.68E+00 TM 20 42157 05/06/98 Cr-51 2.06E+01 1.48E+01 4.71E+01 TM 20 42157 05/06/98 Cs-134 2.17E+00 1.18E+00 3.53E+00 TM 20 42157 05/06/98 Cs-137 2.49E+00 1.23E+00 3.85E+00 TM 20 42157 05/06/98 Fe-59 -0.81E+00 4.09E+00 1.55E+01 TM 20 42157 05/06/98. I-131 -3.38E-02 3.69E-02 0.31E+00 TM 20 42157 05/06/98 K-40 1.30E+03 6.22E+01 6.54E+01
- TM 20 42157 05/06/98 Mn-54 0.88E+00 1.07E+00 3.55E+00 TM 20 42157 05/06/98 Ru-103 -2.83E+00 1.47E+00 5.79E+00 TM -20 42157 05/06/98 Ru-106 3.44E+00 1.27E+01 4.55E+01 TM 20 42157 05/06/98 Sb-124 0.54E+00 3.25E+00 1.16E+01 TM 20 42157 05/06/98 Se~75 1.8DE+00 1.80E+00 5.83E+00 TM 20 42157 05/06/98 Th-232
- 41E+00
. 4.57E+00 1.52E+01 TM 20 42157 05/06/98 Zn-65 -0.32E+00 3.34E+00 1.21E+01 TM 20 42157 05/06/98 Zr-95 1.63E+00 2.60E+00 8.61E+00 e
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
? i i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 20 42282 05/20/98 Ag-110M -0.24E+00 1.74E+00 6.72E+00 TM 20 42282 05/20/98 Ba-140 0.89E+00 2.32E+00 8.73E+00 TM 20 42202 05/20/98 Be-7 6.87E+00 1.08E+01 3.78E+01 TM 20 42282 05/20/98 Ce-141 -1.76E+00 2.41E+00 8.18E+00 TM 20 42282 05/20/98 Ce-144 8.65E+00 1.09E+01 3.38E+01 TM 20 42282 05/20/98 Co-57 -0.73E+00 1.37E+00 4.54E+00 TM 20 42282 05/20/98 Co-58 0.45E+00 1.52E+00 5.45E+00 TM 20 42282 05/20/98 Co-60 -0.87E+00 1.66E+00 6.88E+00 TM 20 42282 05/20/98 Cr-51 -1.74E+01 1.49E+01 5.63E+01 TM 20 42282 05/20/98 Cs-134 1.24E+00 1.46E+00 4.83E+00 TM 20 42282 05/20/98 Cs-137 1.00E+00 2.03E+00 7.31E+00 TM 20 42282 05/20/98 Fe-59 -3.25E+00 4.37E+00 1.84E+01 TM 20 42282 05/20/98 I-111 5.89E-02 7.08E-02 0.34E+00 TM 20 42282 05/20/98 K-40 1.15E+03 7.65E+01 9.30E+01
- TM 20 42282 05/20/98 Mn-54 -1.44E+00 1.55E+00 6.09E+00 TM 20 42282 05/20/98 Ru-103 -0.71E+00 1.70E+00 6.33E+00 TM 20 42282 05/20/98 Ru-106 3.10E+01 1.41E+01 4.24E+01 1 TM 20 42282 05/20/98 Sb-124 -3.16E+00 3.33E+00 1.53E+01 TM 20 42282 05/20/98 Se-75 0.31E+00 2.21E+00 7.59E+00 TM 20 42282 05/20/98 Th-232 4.30E+00 6.32E+00 2.18E+01 TM 20 42282 05/20/98 Zn-65 8.45E+00 4.38E+00 1.34E+01 TM 20 42282 05/20/98 Zr-95 -3.85E+00 2.66E+00 1.10E+01 TM 20 42589 06/03/98 Ag-110M 8.56E-02 1.31E+00 4.53E+00 TM 20 42589 06/03/98 Ba-140 -2.41E+00 1.47E+00 6.70E+00 TM 20 42589 06/03/98 Be-7 1.04E+01 8.47E+00 2.73E+01 TM 20 42589 06/03/98 Ce-141 0.93E+00 1.93E+00 5.96E+00 TM 20 42589 06/03/98 Ce-144 -1.78E+01 6.43E+00 2.21E+01 ,
TM 20 42589 06/03/98 Co-57 0.21E+00 0.90E+00 2.78E+00 l TM 20 42589 06/03/98 Co-58 1.66E+00 0.99E+00 3.01E+00 TM 20 42589 06/03/98 Co-60 2.19E+00 1.26E+00 3.94E+00 TM 20 42589 06/03/98 Cr-51 -1.67E+01 1.13E+01 4.05E+01 TM 20 42589 06/03/98 Cs-134 1.50E+00 1.13E+00 3.31E+00 TM 20 42589 06/01/98 Cs-137 -0.42E+00 1.07E+00 3.98E+00 TM 20 42589 06/03/98 Fe-59 2.78E+00 3.69E+00 1.25E+01 TM 20 42589 06/03/98 I-131 0.17E+00 0.13E+00 0.55E+00 l TM 20 42589 06/03/98 K-40 1.33E+03 5.29E+01 5.74E+01
- TM 20 42589 06/03/98 Mn-54 0.61E+00 0.93E+00 3.08E+00 TM 20 42589 06/03/98 Ru-103 1.74E+00 1.10E+00 3.47E+00 TM 20 42589 06/03/98 Ru-106 -3.57E+00 8.82E+00 3.30E+01 TM 20 42589 06/03/98 Sb-124 -2.94E+00 1.98E+00 8.77E+00 TM 20 42589 06/03/98 Se-75 1.30E+00 1.38E+00 4.48E+00 TM 20 42589 06/03/98 Th-232 -0.13E+00 3.93E+00 1.37E+01 TM 20 42589 06/03/98 Zn-65 -6.74E+00 2.57E+00 1.05E+01 TM 20 42589 06/03/98 Zr-95 3.15E+00 1.85E+00 5.62E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l.
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pC1/kg) TM 20- 42693 06/17/98 Ag-110M 1.11E+00 2.55E+00 9.05E+00 TM 20 42693 06/17/98 Ba-140 -3.53E+00 2.96E+00 1.38E+01 TM 20 42693. 06/17/98 Be-7 1.46E+01 1.66E+01 5.58E+01 TM ' 20 42693 06/17/98 Ce-141 -3.17E+00 2.88E+00 9.84E+00 TM 20 42693 06/17/98 Ce-144 8.52E+00 1.25E+01 3.87E+01 TM 20- -42693 06/17/98 Co-57 -1.76E+00 1.47E+00 4.93E+00 TM 20 42693 06/17/98 Co-58 2.63E+00 2.05E+00 6.53E+00 TM 20 42693 06/17/98 Co-60 -0.87E+00 2.31E+00 9.68E+00 TM 20 42693 06/17/98 Cr-51 -1.03E+01 1.90E+01 6.83E+01 l TM 20 42693 06/17/98 Cs-134 0.60E+00 1.76E+00 6.10E+00 1 TM 20 42693 06/17/98 Cs-137 4.59E+00 2.32E+00 7.27E+00 TM 20 42693 06/17/98 Fe-59 -0.23E+00 5.87E+00 2.31E+01 TM 20 42693 06/17/98 I-131 -4.93E-02 4.17E-02 0.37E+00 TM 20 42693 06/17/98 K-40 1.34E+03 9.84E+01 1.31E+02
- TM 20 42693 06/17/98 Mn-54 -0.66E+00 1.80E+00 6.89E+00 TM- 20 42693 06/17/98 Ru-103 -5.92E+00 2.24E+00 9.39E+00 TM 20 42693 06/17/98 Ru-106 2.10E+01 1.78E+01 6.09E+01 TM 20 42693 06/17/98 Sb-124 -1.03E+00 4.29E+00 1.90E+01 TM 20 42693 06/17/98 Se-75 0.40E+00 2.49E+00 8.56E+00 ,
TM 20 42693 06/17/99 Th-232 -7.49E+00 6.36E+00 2.72E+01 TM 20 42693 06/17/98 Zn-65 -1.15E+01 5.18E+00 2.29E+01 TM 20 42693 06/17/98 Zr-95 -0.39E+00 3.77E+00 1.37E+01 TM 20 42919 07/01/98 Ag-110M -1.47E+09 2.37E+00 8.99E+00
'TM 20 42919 07/01/98 Ba-140 2.26E+t 3.58E+00 1.29E+01 TM 20 42919 07/01/98 Be-7 1.43E+0A 1.56E+01 5.18E+01 TM 20 42919 07/01/98 Ce-141 0.76E+00 2.85E+00 9.04E+00 TM 20 42919 07/01/98 Ce-144 5.70E+00 9.84E+00 3.05E+01 TM 20 42919 07/01/98 Co-57 1.34E+00 1.15E+00 3.50E+00 TM 20 42919 07/01/98 Co-58 0.37E+00 1.92E+00 6.75E+00 l TM 20 42919 07/01/98 Co-60 -1.75E+00 1.83E+00 7.80E+00 l TM 20 42919 07/01/98 Cr-51 7.86E+00 1.70E+01 5.76E+01 TM 20 42919 07/01/98 Cs-134 -1.29E+00 1.42E+00 5.53E+00 TM 20 42919 07/01/98 Cs-137 -2.86E+00 2.13E+00 8.54E+00 TM 20 42919 07/01/98 Fe-59 5.71E+00 6.11E+00 2.10E+01 )
TM 20 42919 07/01/98 I-131 9.10E-03 5.27E-02 0.28E+00 1 TM 20 42919 07/01/98 K-40 1.41E+03 8.82E+01 1.19E+02
- TM 20 42919 07/01/98 Mn-54 0.00E+00 1.34E+00 4.99E+00 TM 20- 42919 07/01/98 Ru-103 0.15E+00 1.76E+00 6.31E+00 TM 20 42919 07/01/98 Ru-106 1.08E+01 1.47E+01 5.24E+01 TM 20 42919 07/01/98 Sb-124 -1.12E+00 2.88E+00 1.35E+01 TM 20 42919- 07/01/98 Se-75 -1.61E+00 2.19E+00 7.76E+00 i ,
TM . 20 42919 07/01/98 Th-232 -5.70E+00 7.21E+00 2.73E+01 j' TM 20 42919 07/01/98 Zn-65 0.64E+00 4.14E+00 1.52E+01 l TM '20 42919 07/01/98 Zr-95 -0.64E+00 4.07E+00 1.~ 53 E+01 t
- Radioactivity detected in sample (i.e., CONC > 3 STD DEV.)
j
l Seabrook Nuclear Power Station c Radiological Environmenta.1. Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 20 43155 07/22/98 Ag-110M -0.53E+00 1.78E+00 6.55E+00 TM 20 43155 07/22/98 Es-140 -1.36E+00 1.53E+00 6.66E+00 TM 20 43155 07/22/98 Be-7 1.18E+00 9.55E+00 3.35E+01 TM 20 43155 07/22/98 Ce-141 -0.23E+00 2.23E+00 7.22E+00 TM 20 43155 07/22/98 Ce-144 1.14E+01 7.93E+00 2.37E+01 TM 20 43155 07/22/98 Co-57 0.87E+00 1.04E+00 3.17E+00 TM 20 43155 07/22/98 Co-58 -0.31E+00 1.28E+00 4.53E+00 TM 20 43155 07/22/98 Co-60 0.14E+00 1.59E+00 5.63E+00 TM 20 43155 07/22/98 Cr-51 9.18E+00 1.22E+01 4.03E+01 TM 20 43155 07/22/98 Cs-134 -1.32E+00 1.05E+00 3.93E+00 TM 20 43155 07/22/98 Cs-137 0.97E+00 1.39E+00 4.86E+00 TM 20 43155 07/22/98 Fe-59 2.48E+00 4.18E+00 1.42E+01 TM 20 43155 07/22/98 I-131 6.83E-02 5.57E-02 0.23E+00 TM 20 43155 07/22/98 K-40 1.28E+03 6.16E+01 7.37E+01
- TM 20 43155 07/22/98 Mn-54 0.39E+00 1.14E+00 3.91E+00 TM 20 43155 07/22/98 Ru-103 -1.60E+00 1.33E+00 5.01E+00 TM 20 43155 07/22/98 Ru-106 4.93E+00 1.15E+01 4.11E+01 TM 20 43155 07/22/98 Sb-124 -0.14E+00 2.59E+00 1.03E+01 TM 20 43155 07/22/98 Se-75 -0.95E+00 1.69E+00 5.86E+00 TM 20 43155 07/22/98 Th-232 1.19E+01 4.82E+00 1.41E+01 TM 20 43155 07/22/98 Zn-65 3.51E+00 2.96E+00 9.74E+00 TM 20 43155 07/22/98 v r -95 0.99E+00 2.22E+00 7.49E+00 TM 20 43394 08/05/98 Ag-110:5 0.52E+00 1.57E+00 5.38E+00 TM 20 43394 08/05/98 Ba-140 -0.25E+00 1.29E+00 5.27E+00 TM 20 43394 08/05/98 Be-7 -2.09E+01 8.95E+00 3.63E+01 TM 20 43394 08/05/98 Ce-141 -1.70E+00 1.80E+00 5.96E+00 TM 20 43394 08/05/98 Ce-144 1.88E+00 7.42E+00 2.33E+01 TM 20 43394 08/05/98 Co-57 -0.16E+00 0.98E+00 3.12E+00 TM 20 43394 08/05/98 Co-58 1.19E+00 1.13E+00 3.63E+00 TM 20 43394 08/05/98 Co-60 0.90E+00 1.24E+00 4.31E+00 TM 20 43394 08/05/98 Cr-51 -1.19E+01 1.04E+01 3.81E+01 TM 20 43394 08/05/98 Cs-134 -1.15E+00 0.99E+00 3.70E+00 TM 20 43394 08/05/98 Cs-137 1.55E+00 1.30E+00 4.41E+00 TM 20 43394 08/05/98 Fe-59 0.33E+00 2.97E+00 1.11E+01 TM 20 43394 08/05/98 I-131 0.14E+00 0.11E+00 0.44E+00 TM 20 43394 08/05/98 K-40 1.38E+03 6.19E+01 6.69E+01
- TM 20 43394 08/05/98 Mn-54 -0.28E+00 0.99E+00 3.59E+00 TM 20 43394 08/05/98 Ru-103 -0.70E+00 1.19E+00 4.33E+00 TM 20 43394 08/05/98 Ru-106 0.00E+00 9.11E+00 3.42E+01 TM 20 43394 08/05/98 Sb-124 -0.93E+00 2.35E+00 9.52E+00 TM 20 43394 08/05/98 Se-75 -0.60E+00 1.48E+00 5.13E+00 TM 20 43394 08/05/98 Th-232 -0.71E+00 4.21E+00 1.52E+01 TM 20 43394 08/05/98 Zn-65 5.71E-02 2.93E+00 1.05E+01 TM 20 43394 08/05/98 Zr-95 -2.06E+00 2.11E+00 8.40E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
r Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 20 43691 08/19/98 Ag-110M -0.65E+00 1.69E+00 6.38E+00 TM 20 43691 08/19/98 Ba-140 -0.57E+00 2.01E+00 8.48E+00 TM 20 43691 08/19/98 Be-7 -1.86E+01 1.12E+01 4.42E+01 TM 20 43691 08/19/98 Ce-141 6.17E-02 2.33E+00 7.34E+00 i TM 20 43691 08/19/98 Ce-144 1.05E+01 8.58E+00 2.58E+01 I TM 20 43691 08/19/98 Co-57 0.24E+00 1.02E+00 ,, 3.19E+00 f TM 20 43691 08/19/98 Co-58 -1.51E+00 1.60E+00 6.00E+00 TM 20 43691 08/19/98 Co-60 0.41E+00 1.60E+00 6.10E+00 TM 10 43691 08/19/98 Cr-Si 1.38E+01 1.48E+01 4.84E+01 TM 20 43691 08/19/98 Cs-134 -1.10E+00 1.16E+00 4.35E+00 TM 20 43691 08/19/98 Cs-137 1.95E+00 1.62E+00 5.46E+00 TM 20 43691 08/19/98 Fe-59 -6.30E+00 5.23E+00 2.11E+01 ! TM 20 43691 08/19/98 I-131 -2.44E-02 5.62E-02 0.36E+00 ) TM 20 43691 08/19/98 K-40 1.29E+03 7.25E+01 8.13E+01
- i TM 20 43691 08/19/98 Mn-54 -1.67E+00 1.26E+00 5.02E+00 TM 20 43691 08/19/98 Ru-103 2.59E+00 1.46E+00 4.503+00 OM 20 43691 08/19/98 Ru-106 -1.90E+01 1.33E+01 5.03E+01 TM 20 43691 08/19/98 Sb-124 2.10E+00 3.51E+00 1.30E+01 TM 20 43691 08/19/98 Se-75 5.96E-02 1.66E+00 5.67E+00 TM 20 43691 08/19/98 Th-232 6.07E+00 6.03E+00 1.99E+01 TM 20 43691 08/19/98 Zn-65 -8.80E+00 4.27E+00 1.73E+01 TM 20 43691 08/19/98 Zr-95 2.13E+00 2.51E+00 8.28E+00 l
TM 20 43979 09/C2/98 Ag-110M -1.11E+00 2.04E+00 7.76E+00 TM 20 43979 09/02/98 Ba-140 -6.77E+00 2.77E+00 1.39E+01 TM 20 43979 09/02/98 Be-7 -3.88E+00 1.28E+01 4.67E+01 TM 20 43979 09/02/98 Ce-141 -1.84E+00 2.59E+00 8.44E+00 TM 20 43979 09/02/98 Ce-144 -3.58E+00 9.06E+00 2.92E+01 TM 20 43979 09/02/98 Co-57 1.21E+00 1.15E+00 3.49E+00 TM 20 43979 09/02/98 Co-58 -0.74E+00 1.37E+00 5.33E+00 TM 20 43979 09/02/98 Co-60 -2.71E+00 2.15E+00 9.11E+00 TM 20 43979 09/02/98 Cr-51 -5.04E+00 1.52E+01 5.37E+01 TM 20 43979 09/02/98 Cs-134 1.18E+00 1.58E+00 5.55E+00 TM 20 43979 09/02/98 Cs-137 2.02E+00 1.94E+00 6.63E+00 TM 20 43979 09/02/98 Fe-59 4.15E+00 5.71E+00 2.00E+01 TM 20 43979 09/02/98 I-131 -6.42E-03 4.02E-02 0.26E+00 TM 20 43979 09/02/98 K-40 1.26E+03 7.80E+01 9.08E+01
- TM 20 43979 09/02/98 Mn-54 2.59E+00 1.58E+00 4.81E+00 TM 20 43979 09/02/98 Ru-103 -0.68E+00 1.69E+00 6.19E+00 TM 20 43979 09/02/98 Ru-106 -1.22E+01 1.48E+01 5.85E+01 TM 20 43979 09/02/98 Sb-124 4.07E+00 4.35E+00 1.53E+01 TM 20 43979 09/02/98 Se-75 1.63E+00 1.87E+00 6.15E+00 TM 20 43979 09/02/98 Th-232 4.59E+00 6.46E+00 2.20E+01 TM 20 43979 09/02/98 Zn-65 3.32E+00 4.58E+00 1.57E+01 TM 20 43979 09/02/98 Zr-95 2.54E+00 3.26E+00 1.08E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l L-_
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE ~ STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM - 20 44367 09/23/98- Ag-110M -8.27E-02 :1.81E+00 6.43E+00 TM 20 44367 09/23/98 Ba-140- 0.12E+00 1.81E+00 7.19E+00 TM 20 44367 09/23/98 Be-7 -2.02E+01 1.11E+01 4.32E+01 ' TM 20 44367 09/23/98 Ce-141 -4.04E+00 2.06E+00 6.94E+00 TM 20 44367 09/23/98- 'Ce-144 -2.59E+01 7.54E+00 2.65E+01 TM 20 44367 09/23/98 Co-57 2.38E-02 0.96E+00 3.02E+00 TM 20- 44367 09/23/98 Co-58 0.23E+00 1.45E+00 5.02E+00 TM 20 44367 09/23/98 Co-60 1.64E+00 1.76E+00 6.16E+00 TML 20 44367 '09/23/98 Cr-51 1.36E+01 1.17E+01' 3.78E+01 TM 44367 09/23/98 Cs-134 0.71E+00 1.35E+00 4.75E+00 TM 20 44367 09/23/98 Cs-137 2.16E+00 1.65E+00 5.52E+00 TM - 20- 44367 09/23/98 Fe-59 -6.99E+00 4.07E+00 1.75E+01 TM 20 44367 09/23/98 I-131 -2.51E-02 3.90E-02 0.32E+00 TM 20~ 44367 09/23/98 K-40 1.41E+03 7.19E+01 8.52E+01
- TM 20 44367 09/23/98 Mn-54 0.68E+00 1.44E+00 4.82E+00 TM 20 44367 09/23/98- Ru-103 0.30E+00 1.54E+00 5.30E+00
- TM 20 44367 09/23/98 Ru-106 7.28E+00 1.43E+01 5.05E+01 TM 20 44367 09/23/98 Sb-124. -0.73E+00 3.18E+00 1.30E+01 TM 20 44367 09/23/98 Se-75 -0.92E+00 1.82E+00 6.25E+00 TM 20 44367 09/23/98 Th-232 -8.41E+00 5.11E+00 2.03E+01 TM 20 44367 09/23/98 Zn-65 -4.37E+00 4.04E+00 1.53E+01 TM 20 44367 09/23/98 Zr -6.20E+00 2.36E+00 9.82E+00 TM 20 45112 10/14/98 Ag-110M 1.09E+00 1.17E+00 3.74E+00 TM 20 45112 10/14/98 Ba-140 0.89E+00 1.22E+00 4.20E+00 TM 20 45112 10/14/98 Be-7 3.87E+00 7.61E+00 2.53E+01 TM 20 45112 10/14/98 Ce-141 0.42E+00 1.51E+00 4.66E+00 TM 20 45112 10/14/98 Ce-144 6.67E+00 5.77E+00 1.73E+01 TM 2'O 45112 10/14/98 Co-57 -0.80E+00 0.72E+00 2.30D+00 TM 20 45112 '10/14/98 Co-58 -0.79E+00 0.88E+00 3.13E+00 TM 20 45112 10/14/98 Co-60 -0.12E+00 0.89E+00 3.22E+00 TM .20 45112 10/14/98 Cr-51 -1.04E+01 9.11E+00 3.18E+01 TM 20 45112 =10/14/98 Cs-134 0.59E+00 0.90E+00 2.84E+00 TM 20 45112 10/14/98 Cs-137 2.33E+00 0.96E+00 3.02E+00 TM 20 45112 10/14/98 Fe-59 -3.48E+00 2.83E+00 1.07E+01 TM 20 45112 10/14/98 I-131 -3.16E-02 4.83E-02 0.40E+00 TM 20 45112 10/14/98 K-40 1.24E+03 4.32E+01 4.48E+01
- TM 20 45112 10/14/98 Mn-54 0.29E+00 0.80E+00 2.65E+00 TM 20 45112 10/14/98 Ru-103 0.30E+00 0.91E+00 3.08E+00 TM 20 45112 10/14/98 Ru-106 -1.72E+00 8.43E+00 3.04E+01 TM 20 45112 10/14/98 Sb-124 1.31E+00 2.04E+00 6.96E+00 TM 20 45112 10/14/98 Se-75 -0.88E+00 1.22E+00 4.16E+00 TM 20 45112 10/14/98 Th-232 ~1.06E+00 3.40E+00 1.14E+01 TM 20 45112 10/14/98 Zn-65 -4.76E+00- 2.20E+00 8.49E+00 TM 20 45112 10/14/98 Zr-95 -0.54E+00 1.53E+00 5.28E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I' I l I Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data j SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 20 45709 11/18/98 Ag-110M -1.03E+00 1.63E+00 6.04E+00 TM 20 45709 11/18/98 Ba-140 -1.15E+00 1.44E+00 6.31E+00 TM 20 45709 11/18/98 Be-7 9.14E+00 9.87E+00. 3.27E+01 l TM 20 45709 11/18/98 Ce-141 -0.97E+00 2.09E+00 6.77E+00 TM 20 45709 11/18/98 Ce-144 7.02E+00 8.08E+00 2.47E+01 TM 20 45709 11/18/98 Co-57 0.50E+00 0.99E+00 3.09E+00 l TM 20 45709 11/18/98 Co-58 -0.49E+00 1.25E+00 4.51E+00 TM 20 45709 11/18/98 Co-60 -6.92E-02 1.32E+00 4.97E+00 TM 20 45709 11/18/98 Cr-51 -1,35E+00 1.07E+01 3.75E+01 TM 20 45709 11/18/98 Cs-134 -0.29E+00 0.92E+00 3.34E+00 TM 20 45709 11/18/98 Cs-137 2.61E+00 1.49E+00 4.82E+00 TM 20 45709 11/18/98 Fe-59 2.45E+00 4.26E+00 1.48E+01 TM 20 45709 11/18/98 I-131 -1.70E-02 5.10E-02 0.34E+00 ' TM 20 45709 11/18/98 K-40 1.38E+03 6.44E+01 7.08E+01
- TM 20 45709 11/18/98 Mn-54 1.79E+00 1.19E+00 3.66E+00 TM 20 45709 11/18/98 Ru-103 -0.90E+00 1.22E+00 4.53E+00 :
TM 20- 45709 11/18/98 Ru-106 -1.04E+01 1.10E+01 4.34E+01 ) TM 20 45709 11/18/98 Sb-124 -3.11E+00 2.19E+00 1.03E+01 1 TM 20' 45709 11/18/98 Se-75 0.65E+00 1.60E+00 5.35E+00 l TM 20 45709 .11/18/98 Th-232 7.25E+00 4.72E+00 1.49E+01 l TM' 20 45709 11/18/98 Zn-65 2.16E+00 2.95E+00 1.01E+01 l TM 20 45709 11/18/98 Zr-95 0.37E+00 1.96E+00 6.87E+00 TM 20 46236 12/16/98 Ag-110M -0.91E+00 1.39E+00 4.84E+00 TM 20 46236 12/16/98 Ba-140 0.26E+00 1.74E+00 6.21E+00 TM 20 46236 12/16/98 Be-7 3.32E+00 9.18E+00 3.06E+01 TM 20 46236 12/16/98 Ce-141 1.50E+00 2.16E+00 6.54E+00 l TM 20 46236 12/16/98 Ce-144 -5.97E+00 7.64E+00 2.39E+01 TM 20 46236 12/16/98 Co-57 -0.79E+00 1.03E+00 3.21E+00
- TM 20 46236 12/16/98 Co-58 3.13E-02 1.08E+00 3.63E+00 l TM 20 46236 12/16/98 Co-60 0.19E+00 1.16E+00 4.08E+00 TM 20 46236 12/16/98 Cr-51 2.20E+00 1.17E+01 3.87E+01 TM 20 46236 12/16/98 Cs-134 6.93E-02 0.99E+00 3.26E+00 TM 20 46236 12/16/98 Cs-137 2.12E+00 1.24E+00 4.04E+00 TM 20 46236 12/16/98 Fe-59 0.59E+00 2.89E+00 1.02E+01 TM 20 46236 12/16/98 I-131 -3.59E-02 3.56E-02 0.30E+00 TM 20 46236 12/16/98 K-40 1.26E+03 4.61E+01 5.04E+01
- TM 20 46236 12/16/98 Mn-54 -0.60E+00 1.01E+00 3.48E+00 TM 20 46236 12/16/98 Ru-103 0.24E+00 1.18E+00 3.97E+00 TM 20 46236 12/16/98 Ru-106 -1.33E+01 9.21E+00 3.51E+01 TM 20 46236 12/16/98 Sb-124 -0.86E+00 1.91E+00 7.37E+00 TM 20 46236 12/16/98 Se-75 -1.55E+00 1.53E+00 5.18E+00 TM 20 46236 12/16/98 Th-232 -0.64E+00 3.81E+00 1.31E+01 TM 20 46236 '12/16/98 Zn-65 1.75E+00 6.35E+00 2.35E+01 TM 20 46236 12/16/98 Zr-95 -1.74E+00 1.89E+00 C.65E+00 I
I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
l
)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 21 40358 01/14/98 Ag-110M 0.79E+03 1.79E+00 6.26E+00 TM 21 40358 01/14/98 Ba-140 -0.53E+00 0.38E+00 3.90E+00 TM 21 40358 01/14/98 Be-7 -0.25E+00 9.90E+00 3.51E+01 TM 21 40358 01/14/98 Ce-141 -3.24E+00 2.42E+00 8.14E+00 TM 21 40358 01/14/98 Ce-144 -1.46E+01 8.08E+00 2.73E+01 TM 21 40358 01/14/98 Co-57 1.33E+00 1.08E+00 3.25E+00 TM 21 40358 01/14/98 Co-58 -0.48E+00 1.14E+00 4.18E+00 TM 21 40358 01/14/98 Co-60 -0.43E+00 1.28E+00 4.83E+00 TM 21 40358 01/14/98 Cr-51 1.08E+01 1.24E+01 4.07E+01 TM 21 40358 01/14/98 Cs-134 -3.38E+00 1.32E+00 5.41E+00 TM 21. 40358 01/14/98 Cs-137 0.00E+00 1.13E+00 4.25E+00 TM 21 40358 01/14/98 Fe-59 -0.88E+00 4.21E+00 1.53E+01 TM 21 40358 01/14/98 I-131 1.02E-02 6.06E-02 0.37E+00 TM 21 40358 01/14/98 K-40 1.35E+03 6.27E+01 6.87E+01
- TM 21 40358 01/14/98 Mn-54 -0.80E+00 1.23E+00 4.47E+00 TM 21 40358 01/14/98 Ru-103 1.39E+00 1.31E+00 4.35E+00 TM 21 40358 01/14/98 Ru-106 6.62E+00 9.65E+00 3.43E+01 TM 21 40358 01/14/98 Sb-124 -5.45E+00 2.38E+00 1.20E+01 TM 21 40358 01/14/98 Se-75 2.13E+00 1.74E+00 5.58E+00 TM 21 40358 01/14/98 Th-232 1.86E+00 4.88E+00 1.72E+01 TM 21 40358 01/14/98 Zn-65 3.61E+00 3.06E+00 1.01E+01 TM 21 40358 01/14/98 Zr-95 -1.77E+00 1.98E+00 7.53E+00 TM 21 40878 02/11/98 Ag-110M 4.72E-02 1.39E+00 4.73E+00 TM 21 40878 02/11/98 Ba-140 0.48E+00 1.35E+00 4.83E+00 TM 21 40878 02/11/98 Be-7 -2.83E+00 7.90E+00 2.79E+01 TM 21 40878 02/11/98 Ce-141 -0.66E+00 1.64E+00 5.25E+00 TM 21 40878 02/11/98 Ce-144 -3.93E+00 6.19E+00 1.98E+01 TM 21 40878 02/11/98 Co-57 -0.35E+00 0.82E+00 2.61E+00 TM 21 40878 02/11/98 Co-58 0.86E+00 0.86E+00 2.79E+00 TM 21 40878 02/11/98 Co-60 1.38E+00 1.16E+00 3.80E+00 TM 21 40878 02/11/98 Cr-51 -4.83E+00 8.44E+00 2.95E+01 TM 21 40878 02/11/98 Cs-134 0.95E+00 0.92E+00 3.12E+00 TM 21 40878 02/11/98 Cs-137 2.70E+00 1.03E+00 2.92E+00 TM 21 40878 02/11/98 Fe-59 0.12E+00 3.03E+00 1.09E+01 TM 21 40878 02/11/98 I-131 3.50E-02 7.37E-02 0.38E+00 TM 21 40878 02/11/98 K-40 1.49E+03 5.31E+01 5.01E+01
- TM 21 40878 02/11/98 Mn-54 1.74E+00 0.94E+00 2.82E+00 TM 21 40878 02/11/98 Ru-103 -1.79E+00 0.96E+00 3.66E+00 TM 21 40878 02/11/98 Ru-106 -1.30E+01 9.34E+00 3.61E+01 TM 21 40878 02/11/98 Sb-124 0.66E+00 2.05E+00 7.41E+00 TM 21 40878 02/11/98 Se-75 0.90E+00 1.36E+00 4.45E+00 TM 21 40878 02/11/98 Th-232 -1.60E+00 3.53E+00 1.27E+01 TM 21 40878 02/11/98 Zn-65 3.73E+00 2.48E+00 7.94E+00 TM 21 40878 02/11/98 Zr-95 -0.12E+00 1.68E+00 5.79E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l
\
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE {pCi/kg) (pCi/kg) (pCi/kg) TM 21 41336 03/11/98 Ag-110M 0.78E+00 2.30E+00 7.98E+00 TM 21 41336 03/11/98 Ba-140 2.68E+00 2.19E+00 7.20E+00 TM 21 41336 03/11/98 Be-7 1.38E+01 1.15E+01 3.77E+01 TM 21 41336 03/11/98 Ce-141 -1.77E+00 2.24E+00 7.52E+00 l TM 21 41336 03/11/98 Ce-144 0.78E+00 8.93E+00 2.83E+01 I TM 21 41336 03/11/98 Co-57 1,14E+00 1.13E+00 3.43E+00 i TM 21 41336 03/11/98 Co-58 -3.23E+00 1.67E+00 6.85E+00 TM 21 41336 03/11/98 Co-60 0.88E+00 1.982+00 7.36E+00 TM 21 41336 03/11/98 Cr-51 -1.31E+01 1.31E+01 4.86E+01 TM 21 41336 03/11/98 Cs-134 2.69E+00 1.32E+00 4.11E+00 TM 21 41336 03/11/98 Cs-137 1.22E+00 1.75E+00 6.20E+00 TM 21 41336 03/11/98 Fe-59 7.18E+00 5.47E+00 1.79E+01 TM 21 41336 03/11/98 I-131 -1.37E-02 3.44E-02 0.21E+00 TM 21 41336 03/11/98 K-40 1.37E+03 8.36E+01 1.11E+02
- TM 21 41336 03/11/96 Mn-54 1.38E+00 1.4'P+00 4.84E+00 i TM 21 41336 03/11/98 Ru-103 1.74E+00 1.6'i+00 5.46E+00 TM 21 41336 03/11/98 Ru-106 4.36E+00 1.30E+01 4.82E+01 TM 21 41336 03/11/98 Sb-124 5.35E+00 4.08E+00 1.35E+01 TM 21 41336 03/11/98 Se-75 3.71E+00 1.86E+00 5.71E+00 l TM 21 41336 03/11/98 Th-232 -0.58E+00 5.92E+00 2.18E+01 l TM 21 41336 03/11/98 Zn-65 -3.27E+00 4.35E+00 1.68E+01 TM 21 41336 03/11/98 Zr-95 -0.97E+00 2.52E+00 9.49E+00 TM 21 41608 04/08/98 Ag-110M 0.55E+00 1.85E+00 6.48E+00 TM 21 41608 04/08/98 Ba-140 -1.22E+00 1.12E+00 6.04E+00 TM 21 41608 04/08/98 Be-7 1.30E+01 1.09E+01 3.55E+01 TM 21 41608 04/08/98 Ce-141 -3.01E+00 2.13E+00 7.17E+00 TM 21 41608 04/08/98 Ce-144 -1.95E+00 8.12E+00 2.59E+01 TM 21 41608 04/08/98 Co-57 0.67E+00 1.04E+00 3.21E+00 TM 21 41608 04/08/98 Co-58 -1.33E+00 1.37E+00 5.28E+00 TM 21 41608 04/08/98 Co-60 -1.10E+00 1.98E+00 7.84E+00 TM 21 41608 04/08/98 Cr-51 2.54E+01 1.35E+01 4.17E+01 TM 21 41608 04/08/98 Cs-134 -2.24E+00 1.41E+00 5.29E+00 TM 21 41608 04/08/98 Cs-137 -0.97E+00 1.76E+00 6.65E+00 TM 21 41608 04/08/98 Fe-59 6.33E+00 4.26E+00 1.36E+01 TM 21 41608 04/08/98 I-131 3.45E-02 4.50E-02 0.21E+00 1 TM 21 41608 04/08/98 K-40 1.38E+03 7.47E+01 8.31E+01
- l TM 21 41608 04/08/98 Mn-54 -0.66E+00 1.13E+00 4.34E+00 TM 21 41608 04/08/98 Ru-103 -1.89E+00 1.33E+00 5.19E+00 TM 21 41608 04/08/98 Ru-106 -8.16E+00 1.47E+01 5.58E+01 TM 21 41608 04/08/98 Sb-124 1.77E+00 3.43E+00 1.28E+01 TM 21 41608 04/08/98 Se-75 1.41E+00 1.91E+00 6.26E+00 TM 21 41608 04/08/98 Th-232 -0.52E+00 5.28E+00 1.933+01 3 TM 21 41608 04/08/98 Zn-65 -3.12E+00 3.85E+00 1.48E+01 l TM 21 41608 04/08/98 Zr-95 -3.32E+00 2.65E+00 1.01E*01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
r- ] h, ' l Seabrook Nuclear Power Station l -Radiological Environmental Monitoring Program ! Summary of 1998 Data SAMPLE CONC. STD DEV. MDC L TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pC1/kg) l- TM 21 41907 04/22/98 Ag-110M -1.48E+00 1.97E+00 7.00E+00
- T!! 21 41907 04/22/98 Ba-140 0.20E+00 2.45E+00. 8.87E+00 TM 21 41907 04/22/98 Be-7 -1.66E+01 1.09E+01 4.00E+01 TM 21 '41907 04/22/98 Ce-141 -5.10E+00 1.98E+00 6.63E+00 l TM 21 41907 04/22/98 Ce-144 -0.93E+00- 6.84E+00 2.13E+01 4 TM 21 41907 04/22/98 Co-57 0.60E+00 0.82E+00 2.50E+00 TM 21 41907 04/22/98 Co-58 2.43E+00 1.57E+00 4.84E+00 TM 21- 41907 04/22/98 Co-60 -1.68E+00 1.60E+00 6.41E+00 TM 21 41907 04/22/98 Cr-51 2.27E+01 1.28E+01 3.99E+01 TM 21 41907 04/22/98 Cs-134 -1.17E+00 1.35E+00 4.66E+00 TM 21 41907 04/22/98 Cs-137 -2.63E+00 1.61E+00 6.18E+00 TM 21 41907 04/22/98 Fe-59 0.17E+00 4.56E+00 1.63E+01 TM 21 41907 04/22/98 I-131 3.57E-02 4.66E-02 0.22E+00 TM 21 41907 04/22/98 K-40 1.31E+03 6.56E+01 9.96E+01
- TM 21 41907 04/22/98 Mn-54 2.87E+00 1.48E+00 4.43E+00 TM 21 41907 04/22/98 Ru-103 -0.83E+00 1.57E+00 5.44E+00 TM 21 41907 04/22/98 Ru-106 -1.79E+01 1.38E+01 5.21E+01 TM 21 41907 04/22/98 Sb-124 -3.31E+00 3.60E+00 1.46E+01 I TM 21 41907 04/22/98 Se-75 -1.10E+00 1.66E+00 5.61E+00 TM 21 41907 04/22/98 Th-232 -0.34E+00 6.45E+00 2.20E+01 TM 21 41907 04/22/98 Zn-65 -2.85E+00 3.79E+00 1.38E+01 TM 21 41907 04/22/98 Zr-95 -2.71E+00 2.52E+00 9.05E+00 TM 21 42158 05/06/98 Ag-110M -2.13E+00 1.47E+00 5.40E+00 TM 21 42158 05/06/98 Ba-140 -2.42E+00 1.51E+00 6.36E+00 TM 21 42158 05/06/98 Be-7 -1.35E+01 7.38E+00 2.80E+01 TM 21 42158 05/06/98 Ce-141 -2.26E+00 1.65E+00 5.33E+00 TM 21- 42158 05/06/98 Ce-144 -2.37E+00 .5.79E+00 1.82E+01 TM 21 42158 05/06/98 Co-57 -0_.43E+00 0.72E+00 2.26E+00 TM. 21 42158 05/06/98 Co-58 0.46E+00 1.11E+00 3.68E+00 TM R21 42158 05/06/98 Co-60 0.17E+00 1.20E+00 4.27E+00 l TM 21 42158 05/06/98 Cr-51 -5.41E+00 10.0E+00 3.41E+01 TM 21 42158 05/06/98 Cs-134 -0.70E+00 0.78E+00 2.66E+00 TM 21 42158 05/06/98 Cs-137 1.27E+00 1.19E+00 4.04E+00 TM 21 42158 05/06/98 Fe-59 8.88E+00 3.67E+00 1.09E+01 ;
TM 21 42158 05/06/98 I-131 6.05E-02 8.85E-02 0.45E+00 l l TM 21 42158 05/06/98 K-40 1.40E+03 5.57E+01 7.44E+01
- l TM 21 42158 05/06/98 Mn-54 1.24E+00 1.02E+00 3.20E+00 TM 21 42158 05/06/98 Ru-103 -0.96E+00 1.06E+00 3.80E+00 -
TM 21 42158 05/06/98 Ru-106 -1.49E+01 9.06E+00 3.55E+01 l l- TM 21 _42158 05/06/98 Sb-124 -2.22E+00 2.12E+00 8.81E+00
. TM 21 42158 05/06/98 Se-75 -1.80E+00 1.25E+00 4.36E+00 TM 21 42158 05/06/98 Th-232 -2.79E+00 4.17E+00 1.48E+01 1 'TM 21 42158 05/06/98 Zn -0.69E+00 2.94E+00 1.04E+01 l TM 21 42158 05/06/98 Zr-95 2.66E+00 2.04E+00 6.81E+00 I l
l.
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l l l J
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM' 21 41907 04/22/98 Ag-110M -1.48E+00 1.97E+00 7.00E+00 i TM 21 41907 04/22/98 Ba-140 0.20E+00 2.45E+00 8.87E+00 TM 21 41907 04/22/98 Be-7 -1.66E+01 1.09E+01 -4.00E+01 TM 21 41907 04/22/98 Ce-141 -5.10E+00 1.98E+00 6.63E+00 TM 21 41907 04/22/98 Ce-144 -0.93E+00 6.84E+00 2.13E+01 TM 21 41907 04/22/98 Co-57 0.60E+00 0.82E+00 2.50E+00
.TM 21 41907 04/22/98 Co-58 2.43E+00 1.57E+00 4.84E+00 TM 21 41907 04/22/98 Co-60 -1.68E+00 1.60E+00 6.41E+00 TM 21 .41907 04/22/98 Cr 2.27E+01 1.28E+01 3.99E+01 TM 21 41907 04/22/98 Cs-134 -1.17E+00 1.35E+00 4.66E+00 TM 21 41907 04/22/98 Cs-137 -2.63E+00 1.61E+00 6.18E+00 TM 21 41907 04/22/98 Fe-59 0.17E+00 4.56E+00 1.63E+01 TM 21 41907 04/22/98 I-131 3.57E-02 4.66E-02 0.22E+00 TM 21 41907 04/22/98 K-40 1.31E+03 6.56E+01 9.96E+01
- TM 21 41907 04/22/98 Mn-54 2.87E+00 1.4eE+00 4.43E+00 TM 21 41907 04/22/98 Ru-103 -0.83E+00 1.57E+00 5.44E+00 TM 21 41907 04/22/98 Ru-106 -1.79E+01 1.38E+01 5.21E+01 TM 21 41907 04/22/98 Sb-124 -3.31E+00 3.60E+00 1.46E+01 TM 21 41907 04/22/98 Se-75 -1.10E+00 1.66E+00 5.61E+00 TM 21 41907 04/22/98 Th-232 -0.34E+00 6.45E+00 2.20E+01 TM- 21 41907 04/22/98 Zn-65 -2.85E+00 3.79E+00 1.38E+01 :
TM 21 41907 04/22/98 Zr-95 -2.71E+00 2.52E+00 9.05E+00
-TM 21 42158 05/06/98 Ag-110M -2.13E+00 1.47E+00 5.40E+00 l TM 21 42158 05/06/98 Ba-140 -2.42E+00 1.51E+00 6.36E+00 1 TM 21 42158 05/06/98 Be-7 -1.35E+01 7.38E+00 2.80E+01 TM 21 42158 05/06/98 Ce-141 -2.26E+00 1.65E+00 5.33E+00 TM 21 42158 05/06/98 Ce-144 -2.37E+00 5.79E+00 1.82E+01 TM 21 42158 05/06/93 Co-57 -0.43E+00 0.72E+00 2.26E+00 TM 21 42158 05/06/98 Co-58 0.46E+00 1.11E+00 3.68E+00 TM 21 42158 05/06/98 Co-60 0.17E+00 1.20E+00 4.27E+00 TM 21 42158 05/06/98 Cr-51 -5.41E+00 10.0E+00 3.41E+01 TM 21 42158 05/06/98 Cs-134 -0.70E+00 0.78E+00 2.66E+00 TM 21 42158 05/06/98 Cs-137 1.27E+00 1.19E+00 4.04E+00 TM 21 42158 05/06/98 Fe-59 8.88E+00 3.67E+00 1.09E+01 TM 21 42158 05/06/98 I-131 6.05E-02 8.85E-02 0.45E+00 TM 21 42158 05/06/98 K-40 1.40E+03 5.57E+01 7.44E+01
- TM 21 42158 05/06/98 Mn-54 1.24E+00 1.02E+00 3.20E+00 TM 21 42158 05/06/98 Ru-103 -0.96E+00 1.06E+00 3.80E+00 TM 21 42158 05/06/98 Ru-106 -1.49E+01 9.06E+00 3.55E+01 TM 21 42158 05/06/98 Sb-124 -2.22E+00 2.12E+00 8.81E+00 TM 21 42158 05/06/98 Se -1.80E+00 1.25E+00 4.36E+00 TM 21 42158 05/06/98 Th-232 -2.79E+00 4.17E+00 1.48E+01 ;
.TM 21 42158 05/06/98 Zn-65 -0.69E+00 2.94E+00 1.04E+01 l TM 21 42158- 05/06/98 Zr-95 2.66E+00 2.04E+00 6.81E+00 1
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
i C
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM - 21 42283 05/20/98 Ag-110M -1.30E+00 2.45E+00 9.45E+00 TM 21 42283 05/20/98 Ba-140 4.30E+00 2.22E+00 6.31E+00 TM 21 42283 05/20/98 Be-7 -4.32E+00 1.42E+01 5.21E+01 TM 21 42283 05/20/98 Ce-141 -1.72E+00 3.12E+00 1.03E+01 TM 21 42283 05/20/98 Ce-144 -2.56E+00 1.08E+01 3.50E+01 TM 21 42283 05/20/98 Co-57 0.61E+00 1.37E+00 4.32E+00 TM 21 42283 05/20/98 Co-58 -2.33E+00 1.57E+00 6.45E+00 TM 21 42283 05/20/98 Co-60 0.98E+00 1.89E+00 6.70E+00 TM 21 42283 05/20/98 Cr-51 4.94E+00 1.64E+01 5.63E+01 TM 21 42283 05/20/98 Cs-134 -1.20E+00 1.46E+00 5.48E+00 : TM 21 42283 05/20/98 Cs-137 -0.32E+00 1.86E+00 7.09E+00 TM 21 42283 05/20/98 Fe-59 -0.69E+00 4.66E+00 1.78E+01 TM 21 42283 05/20/98 I-131 1.60E-02 4.92E-02 0.26E+00 TM 21 42283 05/20/98 K-40 1.37E+03 8.37E+01 1.17E+02 * ) TM 21 42283 05/20/98 Mn-54 -2.38E+00 1.57E+00 6.39E+00 TM 21 42283 05/20/98 Ru-103 -3.43E+00 1.72E+00 7.08E+00 TM 21 42283 05/20/98 Ru-106 -1,68E+00 1.41E+01 5.44E+01 TM 21 42283 05/20/98 Sb-124 2.28E+00 3.982+00 1.48E+01 s TM 21 42283 05/20/98 Se-75 -4.09E+00 1.93E+00 7.58E+00 l TM 21 42283 05/20/98 Th-232 -1.24E+01 6.73E+00 2.82E+01 { TM 21 42283 05/20/98 Zn-65 1.19E+00 4.65E+00 1.66E+01 TM 21 42283 05/20/98 Zr-95 -1.34E+00 2.84E+00 1.07E+01 ] TM 21 42590 06/03/98 Ag-110M 5.75E-02 1.69E+00 5.76E+00 TM 21 42590 06/03/98 Ba-140 0.19E+00 1.54E+00 5.98E+00 TH 21 42590 06/03/98 Be-7 -2.42E+00 1,02E+01 3.58E+01 TM 21 42590 06/03/98 Ce-141 -0.36E+00 1.93E+00 6.19E+00 TM 21 42590 06/03/98 Ce-144 -5.66E+00 6.14E+00 2.02E+01 i TM 21 42590 06/03/98 Co-57 -0.77E+00 0.87E+00 2.84E+00 i TM 21 42590 06/03/98 Co-58 -0.39E+00 liO8E+00 3.87E+00 TM 21 42590' 06/03/98 Co-60 -0.27E+00 1.27E+00 4.67E+00 TM 21 42590 06/03/98 Cr-51 -3.16E+01 1.16E+01 4.43E+01 TM 21 42590 06/03/98 Cs-134 -9.59E-02 0.93E+00 3.20E+00 TM 21 42590 06/03/98 Cs-137 1.85E+00 1.23E+00 4.07E+00 TM 21 42590 06/03/98 Fe-59 5.83E+00 3.45E+00 1.08E+01 ; TM 21 42590 06/03/98 I-131 -1.89E-02 6.91E-02 0.37E+00 TM 21 42590 06/03/98 K-40 1.40E+03 5.72E+01 6.57E+01
- TM 21 42590 06/03/98 Mn-54 0.23E+00 1.08E+00 3.67E+00 TM 21 42590 06/03/98 Ru-103 -1.53E+00 1.25E+00 4.64E+00 TM 21 42590 06/03/98 Ru-106 -5.27E+00 9.31E+00 3.54E+01 TM 21 42590 06/03/98 Sb-124 0.48E+00 2.25E+00 8.40E+00 TM 21 42590 06/03/98 Se-75 -1.85E+00 1.47E+00 5.20E+00 TM 21 42590 06/03/98 Th-232 1.40E+00 3.91E+00 1.37E+01 TM 21 42590 06/03/98 Zn-65 0.97E+00 3.03E+00 1.05E+01 TM 21- 42590 06/03/98 Zr-95 3.34E+00 1.94E+00 6.29E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 21 42694 06/17/98 Ag-110M 8.05E+00 3.64E+00 1.01E+01 TM 21 42694 06/17/98 Ba-140 -1.32E+00 1.18E+00 9.04E+00 i TM 21 42694 06/17/98 Be-7 1.35E+01 1.61E+01 5.52E+01 i l TM 21 42694 06/17/98 Ce-141 0.13E+00 3.14E+00 1.03E+01 I TM 21 42694 06/17/98 Ce-144 -0.94E+00 1.12E+01 3.70E+01 I TM 21 42694 06/17/98 Co-57 -1.13E+00 1.52E+00 5.13E+00 TM 21 42694 06/17/98 Co-58 -4.64E+00 2.48E+00 1.06E+01 , TM 21 42694 06/17/98 Co-60 0.60E+00 2.36E+00 9.35E+00 21 l TM 42694 06/17/98 Cr-51 4.70E+00 2.05E+01 7.15E+01 TM 21 42694 06/17/98 Cs-134 -2.95E+00 2.04E+00 8.47E+00 TM 21 42694 06/17/98 Cs-137 1.59E+00 2.43E+00 8.82E+00 TM 21 42694 06/17/98 Fe-59 -1.28E+00 8.07E+00 3.17E+01 TM 21 42694 06/17/98 I-131 0.10E+00 8.07E-02 0.34E+00 TM 21 42694 06/17/98 K-40 1.40E+03 1.14E+02 1.60E+02
- TM 21 42694 06/17/98 Mn-54 -0.59E+00 2.01E+00 7.85E+00 TM 21 42694 06/17/98 Ru-103 -0.77E+00 2.49E+00 9.29E+00 TM 21 42694 06/17/98 Ru-106 -1.78E+01 2.26E+01 9.20E+01 TM 21 42694 06/17/98 Sb-124 5.08E+00 4.09E+00 1.33E+01 TM 21 42694 06/17/98 Se-75 2.97E+00 2.74E+00 8.94E+00 TM 21 42694 06/17/98 Th-232 -4.22E+00 8.90E+00 3.48E+01 TM 21 42694 06/17/98 Zn-65 -7.14E+00 6.15E+00 2.57E+01 TM 21 42694 06/17/98 Zr-95 0.86E+00 3.00E+00 1.21E+01 TM 21 42920 07/01/98 Ag-110M -1.11E+00 2.01E+00 7.56E+00 l TM 21 -2.46E+00 1.04E+01 42920 07/01/98 Ba-140 2.12E+00 TM 21 42920 07/01/98 Be-7 1.13E+01 1.32E+01 4.42E+01 TM 21 42920 07/01/98 Ce-141 -1.41E+00 2.74E+00 8.99E+00 TM 21 42920 07/01/98 Ce-144 -1.24E+01 9.00E+00 3.02E+01 TM 21 42920 07/01/98 Co-57 -1,30E+00 1.16E+00 3.84E+00 TM 21 42920 07/01/98 Co-58 0.61E+00 1.62E+00 5.58E+00 TM 21 42920 07/01/98 Co-60 2.39E+00 1.79E+00 5.83E+00 TM 21 42920 07/01/98 Cr-51 7.52E+00 1.55E+01 5.24E+01 TM 21 42920 07/01/98 Cs-134 -0.65E+00 1.36E+00 4.89E+00 TM 21 42920 07/01/98 Cs-137 3.18E+00 1.63E+00 5.16E+00 TM 21 42920 07/01/98 Fe-59 8.20E+00 5.70E+00 1.84E+01 TM 21 42920 07/01/98 I-131 3.92E-02 5.40E-02 0.26E+00 TM 21 42920 07/01/98 K-40 1.44E+03 7.97E+01 1.04E+02
- TM 21 42920 07/01/98 Mn-54 0.63E+00 1.52E+00 5.21E+00 TM 21 42920 07/01/98 Ru-103 -4.34E+00 1.48E+00 6.41E+00 TM 21 42920 07/01/98 Ru-106 8.99E+00 1.19E+01 4.23E+01 TM 21 42920 07/01/98 Sb-124 -4.95E+00 2.59E+00 1.39E+01 TM 21 42920 07/01/98 Se-75 0.45E+00 2.01E+00 6.80E+00 TM 21 42920 07/01/98 Th-232 -3.13E+00 5.83E+00 2.18E+01 TM 21 42920 07/01/98 Zn-65 -6.56E+00 3.61E+00 1.52E+01 TM 21 42920 07/01/98 Zr-95 -1.84E+00 2.36E+00 9.22E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
.c Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
TM 21 42156 07/22/98- Ag-110M -0.38E+00 1.34E+00 4.67E+00 TM- 21 43156 07/22/98 Ba-140 0.81E+00 1.39E+00 4.83E+00 TM 21 43156 07/22/98 Be-7 -7.64E+00 8.47E+00 3.04E+01 TM 21 43156 07/22/98 Ce-141 -3.85E+00 1.77E+00 5.88E+00 TM 21 43156 07/22/98 Ce-144 -6.69E+00 6.57E+00 2.12E+01 TM 21 43156 07/22/98 Co-57 -0.45E+00 0.87E+00 2.75E+00-TM 21 43156 07/22/98 Co-58 -0.24E+00 1.04E+00 3.59E+00 TM 21 43156 07/22/98 Co-00 -1.89E+00 1.03E+00 4.25E+00 TM 21 43156 07/22/98 Cr-51 -4.48E+00 1.02E+01 3.48E+01 TM 21 43156 07/22/98 Cs-134 -0.95E+00 0.89E+00 3.37E+00 TM 21 43156 07/22/98 Cs-137 6.55E+00 1.54E+00 5.23E+00
- TM- 21 43156 07/22/98 Fe-59 0.40E+00 2.85E+00 1.02E+01 TM 21 43156 07/22/98 I-131 4.49E-02 5.12E-02 0.24E+00 TM 21 43156 07/22/98 K-40 1.50E+03 5.37E+01 5.68E+01
- TM 21 43156 07/22/98 Mn-54 0.13E+00 1.00E+00 3.38E+00 TM 21 43156 07/22/98 Ru-103 -0.37E+00 1.03E+00 3.62E+00 TM 21 43156 07/22/98 Ru-106 -1.63E+01 9.27E+00 3.64E+01 ,
TM 21 43156 07/22/98 Sb-124 0.66E+00 2.04E+00 7.36E+00 l TM 21 43156 07/22/98 Se-75 0.45E+00 1.37E+00 4.51E+00 TM 21 43156 07/22/98 Th-232 6.40E+00 4.24E+00 1.33E+01 TM 21 43156 07/22/98 Zn-65 4.14E+00 5.82E+00 2.15E+01 l l TM 21 43156 07/22/98 Zr-95 1.43E+00 1.68E+00 5.83E+00 TM 21 43395 08/05/98 Ag-110M 2.05E+00 1.74E+00 5.50E+00 TM 21 43395 08/05/98 Ba-140 -1.02E+00 1.97E+00 7.72E+00 TM 21 43395 08/05/98 Be-7 -3.48E+00 9.73E+00 3.45E+01 TM 21 43395 08/05/98 Ce-141 -0.67E+00 1.79E+00 5.67E+00 TM 21 43395 08/05/98 Ce-144 4.87E+00 6.77E+00 2.07E+01 TM 21 43395 08/05/98 Co-57 0.99E+00 0.87E+00 2.61E+00 TM 21 43395 08/05/98 Co-58 0.62E+00 1.38E+00 4.60E+00 TM 21 43395 08/05/98 Co-60 0.00E+00 1.53E+00 5.73E+00 l TM 21 43395 08/05/98 Cr-51 7.96E+00 1.17E+01 3.85E+01 i TM- 21 43395 08/05/98 Cs-134- -1.27E+00 1.19E+00 4.54E+00 TM 21 43395 08/05/98 Cs-137 0.35E+00 1.38E+00 4.95E+00 TM 21 43395 08/05/98 Fe-59 -0.43E+00 3.78E+00 1.40E+01 TM 21 43395 08/05/98 I-131 -6.89E-03 5.12E-02 0.33E+00 TM 21 43395 08/05/98 K-40 1.42E+03 6.33E+01 6.01E+01
- TM 21 43395 08/05/98 Mn-54 -1.96E+00 1.12E+00 4.35E+00 TM 21 43395 08/05/98 Ru-103 0.72E+00 1.24E+00 4.17E+00 TM 21 43395 08/05/98 Ru-106 -8.72E+00 1.09E+01 4.16E+01 TM- 21 43395 08/05/98 Sb-124 -0.58E+00 3.21E+00 1.25E+01 TM 21- 43395 08/05/98 Se-75 0.27E+00 1.49E+00 4.98E+00 TM 21 43395 08/05/98 Th-232 -7.94E+00 4.84E+00 1.86E+01 TM 21 43395 08/05/98 Zn-65 -0.29E+00 3.44E+00 1.22E+01 j TM 21 43395 08/05/98 Zr-95 -3.71E+00 2.08E+00 8.07E+00
{
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 21 43692 08/19/98 Ag-110M -1.57E+00 2.06E+00 7.68E+00 TM 21 43692 08/19/98 Ba-140 -0.38E+00 2.37E+00 9.45E+00 TM 21 43692 08/19/98 Be-7 9.01E+00 1.37E+01 4.59E+01 TM 21 43692 08/19/98 Ce-141 0.30E+00 2.38E+00 7.47E+00 TM 21 43692 08/19/98 Ce-144 0.21E+00 9.12E+00 2.85E+01 TM 21 43692 08/19/98 Co-57 -0.79E+00 1.01E+00 3.27E+00 TM 21 43692 08/19/98 Co-58 0.16E+00 1.79E+00 6.14E+00 TM 21 43692. 08/19/98 Co-60 1.46E+00 1.78E+00 6.34E+00 TM 21 43692 08/19/98 Cr-51 -2.08E+01 1.48E+01 5.38E+01 TM 21 43692 03/19/98 Cs-134 -0.59E+00 1.51E+00 5.46E+00 TM 21 43692 08/19/98 Cs-137 0.48E+00 1.59E+00 5.77E+00 TM 21 43692 08/19/98 Fe-59 0.24E+00 5.33E+00 1.95E+01 TM 21 43692 08/19/98 I-131 4.05E-02 6.01E-02 0.30E+00 TM 21 43692 08/19/98 K-40 1.36E+03 7.52E+01 9.61E+01
- TM 21 43692 08/19/98 Mn-54 -0.13E+00 1.47E+00 5.20E+00 TM 21 43692 08/19/98 Ru-103 -1.45E+00 1.62E+00 5.99E+00 TM 21 43692 08/19/98 Ru-106 3.24E+01 1.43E+01 4.43E+01 TM 21 43692 08/19/98 Sb-124 -2.26E+00 3.47E+00 1.49E+01 TM 21 43692 08/19/98 Se-75 0.00E+00 1.85E+00 6.26E+00 TM 21 43692 08/19/98 Th-232 -6.23E+00 6.28E+00 2.35E+01 TM 21 43692 08/19/98 Zn-65 4.46E+00 4.34E+00 1.44E+01 TM 21 43692 08/19/98- Zr-95 -0.93E+00 2.30E+00 8.54E+00 TM 21 43980 09/02/98' Ag-110M 1.22E+00 2.23E+00 7.70E+00 TM 21 43980 09/02/98 Ba-140 0.98E+00 2.81E+00 1.08E+01 TM 21 43980 09/02/98 Be-7 2.60E+01 1.48E+01 4.57E+01 TM 21 43980 09/02/98 Ce-141 -1.14E+00 2.85E+00 9.17E+00 TM 21 43980 09/02/98 Ce-144 4.54E+00 9.58E+00 2.99E+01 TM 21 43980 09/02/98 Co-57 3.59E-02 1.33E+00 4.19E+00 TM 21 43980 09/02/98 Co-58 -1.54E+00 1.65E+00 6.48E+00 TM 21 43980 09/02/98 Co-60 -0.72E+00 2.05E+00 8.09E+00 TM 21 43980 09/02/98 Cr-51 4.15E+00 1.69E+01 5.78E+01 TM 21 43980 09/02/98 Cs-134 -1.76E+00 1.27E+00 4.85E+00 TM 21 43980 09/02/98 Cs-137 1.27E+00 2.01E+00 7.13E+00 TM 21 43980 09/02/98 Fe-59 -4.58E+00 5.2GE+00 2.20E+01 TM 21 43980 09/02/98 I-131 6.87E-03 5.07E-02 0.31E+00 i TM 21 43980 09/02/98 K-40 1.50E+03 9.05E+01 1.18E+02
- TM 21 43980 09/02/98 Mn-54 -0.92E+00 1.67E+00 6.28E+00 TM 21 43980 09/02/98 Ru-103 -1.19E+00 1.93E+00 7.15E+00 TM 21 43980 09/02/98 Ru-106 -8.05E+00 1.45E+01 5.72E+01 TM 21 43980 09/02/98 Sb-124 -4.65E+00 3.90E+00 1.81E+01 TM- 21 43980 09/02/98 Se-75 0.66E+00 2.24E+00 7.56E+00 TM 21 43980 09/02/98 Th-232 -4.44E+00 6.72E+00 2.56E+01 TM- 21 43980 09/02/98 Zn-65 4.01E+00 4.45E+00 1.52E+01 TM 21 43980 09/02/98 Zr-95 1.25E+00 3.41E+00 1.25E+01
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 21 44368 09/23/98 Ag-110M -1.87E+00 1.89E+00 7.38E+00 TM 21 44368 09/23/98 Ba-140 -0.33E+00 2.23E+00 8.89E+00
.TM 21 44368 09/23/98 Be-7 1.11E+01 1.29E+01 4.27E+01 TM 21 44368 09/23/98 Ce-141 0.94E+00 2.34E+00 7.24E+00 TM- 21 44368 09/23/98 Ce-144 0.85E+00 7.94E+00 2.50E+01 TM 21 44368 09/23/98 Co-57 -1.85E+00 1.06E+00 3.54E+00 TM 21 44368 09/23/98 Co-58 0.13E+00 1.31E+00 4.67E+00 TM 21 44368 09/23/98 Co-60 -0.32E+00 1.87E+00 7.03E+00 TM 21 44368 09/23/98 Cr-51 2.36E+01 1.46E+01 4.60E+01 TM 21 44368 09/23/98 Cs-134 0.65E+00 1.28E+00 4.38E+00 TM 21 44368 09/23/98 Cs-137 4.05E+00 1.70E+00 5.22E+00 TM 21 44368 09/23/98 Fe-59 -1.91E+00 5.83E+00 2.16E+01 TM 21 44368 09/23/98 I-131 6.54E-02 7.51E-02 0.35E+00 TM 21 44368 09/23/98 K-40 1.34E+03 7.32E+01 8.73E+01
- TM 21 44368 09/23/98 Mn-54 1.32E+00 1.44E+00 4.69E+00 TM 21 44368 09/23/98 Ru-103 -0.18E+00 1.48E+00 5.27E+00 TM 21 44368 -09/23/98 Ru-106 -1.81E+01 1.25E+01 5.11E+01 TM 21 44368 09/23/98 Sb-124 0.90E+00 3.72E+00 1.39E+01 TM 21 44368 09/23/98 Se-75 0.83E+00 1.76E+00 5.87E+00 TM 21 44368 09/23/98 Th-232 0.24E+00 5.84E+00 2.07E+01 TM 21 44368 09/23/98 Zn-65 7.88E-02 4.04E+00 1.45E+01 TM 21 44368 09/23/98 Zr-95 7.33E+00 2.75E+00 7.98E+00 TM 21 45113 10/14/98 Ag-110M 1.03E+00 1.30E+00 4.23E+00 TM 21 45113 10/14/98' Ba-140 1.20E+00 1.60E+00 5.56E+00 TM 21 45113 10/14/98 Be-7 4.83E+00 9.48E+00 3.17E+01 TM 21 45113 10/14/98 Ce-141 -1.59E+00 1.87E+00 6.09E+00 TM 21 45113 10/14/98 Ce-144 -5.91E+00 6.11E+00 1.98E+01 TM 21 45113 10/14/98 Co-57 -0.95E+00 0.77E+00 2.54E+00 TM 21 45113 10/14/98 Co-58 0.52E+00 0.96E+00 3.20E+00 TM 21 45113 10/14/98 Co-60 0.94E+00 1.06E+00 3.58E+00 TM 21 45113 10/14/98 Cr-51 -1.39E+01 1.02E+01 3.67E+01 TM 21 45113 10/14/98 Cs-134 0.96E+00 0.88E+00 2.80E+00 TM 21 45113 10/14/98 Cs-137 -0.40E+00 1.19E+00 4.34E+00 TM 21 45113 10/14/98 Fe-59 -0.45E+00 3.76E+00 1.34E+01 TM 21 45113 10/14/98 I-131 3.10E-03 6.49E-02 0.37E+00 TM 21 45113 10/14/98 K-40 1.42E+03 5.33E+01 5.96E+01
- TM 21 45113 10/14/98 Mn-54 0.75E+00 0.91E+00 2.97E+00 TM 21 45113 10/14/98 Ru-103 -1.02E+00 1.10E+00 4.00E+00 i TM 21 45113 10/14/98 Ru-106 1.13E+01 9.16E+00 3.08E+01 TM 21 45113 10/14/98 Sb-124 -2.07E+00 1.67E+00 7.50E+00 TM 21 45113 10/14/98 Se-75 1.27E+00 1.37E+00 4.43E+00 TM 21' 45113 10/14/98 Th-232 -1.90E+00 3.52E+00 1.28E+01 TM 21 45113 10/14/98 Zn-65 -4.60E+00 2.42E+00 9.53E+00 TM 21 45113 10/14/98 Zr-95 -2.34E+00 2.09E+00 8.05E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
L.
I i i l 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC ' TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) TM 21 45710 11/18/98 Ag-110M 0.11E+00 1.90E+00 6.80E+00 l TM 21 45710 11/18/98 Ba-140 0.87E+00 1.91E+00 7.01E+00 . TM 21 45710 11/18/98 Be-7 3.60E+00 9.52E+00 3.29E+01 l TM 21 45710 11/18/98 Ce-141 -1.18E+00 2.48E+00 8.03E+00 l TM 21 45710 11/18/98 Ce-144 -0.66E+00 8.82E+00 2.78E+01 j TM 21 45710 11/18/98 Co-57 -0.76E+00 1.08E+00 3.50E+00 ! TM 21 45710 11/18/98 Co-58 -0.10E+00 1.31E+00 4.57E+00 { TM 21 45710 11/18/98 Co-60 -1.02E+00 1.37E+00 5.28E+00 i TM 21 45710 11/18/98 Cr-51 -3.50E+00 1.26E+01 4.36E+01 TM 21 45710 11/18/98 Cs-134 1.17E+00 1.31E+00 4.20E+00 TM 21 45710 11/18/98 Cs-137 3.69E+00 1.52E+00 4.67E+00 TM 21 45710 11/18/98 Fe-59 -5.74E+00 4.05E+00 1.59E+01 l TM 21 45710 11/18/98 I-131 -3.66E-02 4.93E-02 0.35E+00 I TM 21 45710 11/18/98 K-40 1.46E+03 6.51E+01 7.09E+01
- TM 21 45710 11/18/98 Mn-54 0.35E+00 1.29E+00 4.38E+00 TM 21 45710 11/18/98 Ru-103 -1.93E+00 1.48E+00 5.51E+00 1 TM 21 45710 11/18/98 Ru-106 -6.58E+00 1.23E+01 4.64E+01 5 TM 21 45710 11/18/98 Sb-124 3.18E+00 2.39E+00 7.87E+00 l TM 21 45710 11/18/98 Se-75 -2.63E+00 1.79E+00 6.40E+00 I TM 21 45710 11/18/98 Th-232 1.67E+00 4.68E+00 1.66E+01 i TM 21 45710 11/18/98 Zn-65 -2.71E+00 3.68E+00 1.35E+01 !
TM 21 45710 11/18/98 Zr-95 0.73E+00 2.26E+00 7.68E+00 l TM 21 46237 12/16/98 Ag-110M 0.00E+00 1.40E+00 4.68E+00 TM 21 46237 12/16/98 Ba-140 1.40E+00 1.68E+00 5.61E+00 TM 21 46237 12/16/98 Be-7 -0.40E+00 9.79E+00 3.29E+01 TM 21 46237 12/16/98 Co-141 -1.86E+00 2.28E+00 7.13E+00 TM 21 46237 12/16/98 Ce-144 -1.77E+00 7.85E+00 2.42E+01 TM 21 46237 12/16/98 Co-57 3.02E-02 1.02E+00 3.12E+00 TM 21 46237 12/16/98 Co-58 -1.21E+00 1.04E+00 3.68E+00 TM 21 46237 12/16/98 Co-60 1.70E+00 1.01E+00 3.18E+00 ! TM 21 46237 12/16/98 Cr-51 -4.56E+00 1.23E+01 4.09E+01 1 TM 21 46237 12/16/98 Cs-134 -0.64E+00 1.02E+00 3.40E+00 TM 21 46237 12/16/98 Cs-137 1.44E+00 1.15E+00 3.86E+00 TM 21 46237 12/16/98 Fe-59 1.09E+00 3.51E+00 1.20E+01 TM 21 46237 12/16/98 I-131 7.36E-03 4.52E-02 0.25E+00 TM 21 46237 12/16/98 K-40 1.46E+03 4.79E+01 5.49E+01 * ; TM 21 46237 12/16/98 Mn-54 -0.63E+00 0.90E+00 3.15E+00 3 TM 21 46237 12/16/98 Ru-103 -0.26E+00 1.21E+00 4.09E+00 ' TM 21 46237 12/16/98 Ru-106 0.88E+00 9.95E+00 3.50E+01 TM 21 46237 12/16/98 Sb-124 0.00E+00 2.14E+00 7.73E+00 , TM 21 46237 12/16/98 Se-75 9.99E-02 1.61E+00 5.26E+00 ! TM 21 46237 12/16/98 Th-232 4.83E+00 3.90E+00 1.23E+01 l TM 21 46237 12/16/98 Zn-65 8.47E+00 6.40E+00 2.29E+01 TM 21 46237 12/16/98 Zr-95 -1.40E+00 1.91E+00 7.07E+00 1 )
- Radioactivity detected in sr.mple (i . e . , CONC > 3 STD. DEV. )
~ >
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) Ground Water WG 01 41337 03/12/98 Ag-110M -1.89E+00 1.38E+00 5.53E+00 WG 01 41337 03/12/98 Ba-140 -1.67E+00 1.59E+00 6.65E+00 WG 01 41337 03/12/98 Be-7 0.20E+00 9.01E+00 3.14E+01 WG 01 41337 03/12/98 Ce-141 -3.44E+00 2.07E+00 6.95E+00 WG 01 41337 03/12/98 Ce-144 -5.74E+00 7.70E+00 2.48E+01 WG 01 41337 03/12/98 Co-57 0.74E+00 1.04E+00 3.19E+00 WG 01 41337 03/12/98 Co-58 -0.25E+00 0.88E+00 3.24E+00 WG 01 41337 03/12/98 Co-60 -1.36E+00 1.08E+00 4.37E+00 WG 01 41337 03/12/98 Cr-51 -1.68E+01 1.06E+01 3.87E+01 WG 01 41337 03/12/98 Cs-134 -1.39E+00 0.92E+00 3.47E+00 WG 01 41337 03/12/98 Cs-137 0.82E+00 1.00E+00 3.50E+00 WG 01 41337 03/12/98 Fe-59 -5.91E+00 2.86E+00 1.21E+01 WG 01 41337 03/12/98 GR-B 5.11E+00 0.50E+00 1.40E+00
- WG 01 41337 03/12/98 H-3 -1.41E+01 2.27E+02 8.02E+02 WG 01 41337 03/12/98 I-131 -2.26E+00 2.04E+00 7.43E+00 WG 01 41337 03/12/98 K-40 0.45E+00 1.75E+01 6.18E+01 WG 01 41337 03/12/98 Mn-54 -0.63E+00 0.98E+00 3.58E+00 WG 01 41337 03/12/98 Ru-103 -3.01E+00 1.10E+00 4.49E+00 WG 01 41337 03/12/98 Ru-106 6.94E+00 1.03E+01 3.60E+01 WG 01 41337 03/12/98 Sb-124 -1.72E+00 2.37E+00 9.86E+00 WG 01 41337 03/12/98 Se-75 -0.67E+00 1.64E+00 5.60E+00 i WG 01 41337 03/12/98 Th-232 -0.94E+00 4.63E+00 1.67E+01 j WG 01 41337 03/12/98 Zn-65 1.05E+00 2.16E+00 7.23E+00 l WG 01 41337 03/12/98 Zr-95 1.21E+00 1.66E+00 5.54E+00 l l
WG 01 42596 06/09/98 Ag-110M 1.27E+00 1.22E+00 3.87E+00 WG 01 42596 06/09/98 Ba-140 -1.82E+00 1.49E+00 5.76E+00 WG 01 42596 06/09/98 Be-7 -1.86E+01 7.36E+00 2.77E+01 WG 01 42596 06/09/98 Ce-141 -3.34E+00 1.51E+00 4.91E+00 WG 01 42596 06/09/98 Ce-144 -5.48E+00 5.69E+00 1.79E+01 WG 01 42596 06/09/98 Co-57 0.51E+00 0.74E+00 2.23E+00 WG 01 42596 06/09/98 Co-58 -1.34E+00 0.83E+00 3.10E+00 WG 01 42596 06/09/98 Co-60 0.13E+00 0.95E+00 3.41E+00 WG 01 42596 06/09/98 Cr-51 -1.01E+01 8.41E+00 2.91E+01 WG 01 42596 06/09/98 Cs-134 -0.21E+00 0.72E+00 2.32E+00 WG 01 42596 06/09/98 Cs-137 0.71E+00 0.88E+00 3.03E+00 WG 01 42596 06/09/98 Fe-59 2.94E+00 2.50E+00 8.22E+00 WG 01 42596 06/09/98 GR-B 5.39E+00 0.49E+00 1.34E+00
- WG 01 42596 06/09/98 H-3 7.51E+01 2.23E+02 7.77E+02 WG 01 42596 06/09/98 I-131 2.42E+00 1.67E+00 5.30E+00 WG 01 42596 06/09/98 K-40 -2.17E+01 1.31E+01 5.05E+01 WG 01 42596 06/09/98 Mn-54 0.24E+00 0.83E+00 2.78E+00 WG 01 42596 06/09/98 Ru-103 -1.02E+00 0.90E+00 3.23E+00 WG 01 42596 06/09/98 Ru-106 1.02E+01 7.71E+00 2.57E+01 WG 01 42596 06/09/98 Sb-124 0.75E+00 1.96E+00 6.95E+00 WG 01 42596 06/09/98 Se-75 0.50E+00 1.22E+00 3.97E+00 WG 01 42596 06/09/98 Th-232 -0.20E+00 3.34E+00 1.16E+01 WG 01 42596 06/09/98 Zn-65 0.21E+00 1.76E+00 5.94E+00 WG 01 42596 06/09/98 Zr-95 0.57E+00 1.65E+00 5.84E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
b l Seabrook Nuclear Power Station j Radiological Environmental Monitoring Program : Summary of 1998 Data 1 SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) .
----------------------------- --------------------------------- ---------------- l WG 01 44173 09/10/98 Ag-110M 0.56E+00 1.47E+00 5.00E+00 WG 01 44173 09/10/98 Ba-140 -0.67E+00 1.39E+00 5.60E+00 1 WG 01 44173 09/10/98 Be-7 -1.47E+01 8.87E+00 3.42E+01 l WG 01 44173 09/10/98 Ce-141 3.07E+00 2.18E+00 6.50E+00 l WG 01 44173 09/10/98 Ce-144 1.33E+00 8.22E+00 2.56E+01 l WG 01 44173 09/10/98 Co-57 -0.22E+00 1.05E+00 3.30E+00 WG 01 44173 09/10/98 Co-58 -9.02E-02 1.20E+00 4.16E+00 WG 01 44173 09/10/98 Co-60 1.23E+00 1.09E+00 3.65E+00 WG 01 44173 09/10/98 Cr-51 -8.41E+00 1.13E+01 3.95E+01 ,
WG 01 44173 09/10/98 Cs-134 0.84E+00 0.97E+00 3.14E+00 l WG 01 44173 09/10/98 Cs-137 1.14E+00 2.06E+00 7.91E+00 l WG 01 44173 09/10/98 Fe-59 1.87E+00 2.53E+00 8.94E+00 l WG 01 44173 09/10/98 GR-B 4.54E+00 0.49E+00 1.39E+00
- WG 01 44173 09/10/98 H-3 -2.43E+02 1.82E+02 6.59E+02 WG 01 44173 09/10/98 I-131 1.26E+00 2.37E+00 7.87E+00 WG 01 44173 09/10/98 K-40 1.26E+01 1.63E+01 5.56E+01 l WG 01 44173 09/10/98 Mn-54 -1.51E+00 1.01E+00 3.92E+00 WG 01 44173 09/10/98 Ru-103 -2.22E+00 1.13E+00 4.40E+00 WG 01 44173 09/10/98 Ru-106 -5.72E+00 8.58E+00 3.36E+01 WG 01 44173 09/10/98 Sb-124 2.22E+00 2.39E+00 8.15E+00 WG 01 44173 09/10/98 Se-75 0.66E+00 1.57E+00 5.20E+00 WG - 01 44173 09/10/98 Th-232 -3.24E+00 4.02E+00 1.51E+01 .
WG 01 44173 09/10/98 Zn-65 -0.83E+00 2.42E+00 8.55E+00 l WG 01 44173 09/10/98 Zr-95 2.18E+00 1.65E+00 5.20E+00 WG 01 46034 12/07/98 Ag-110M -0.75E+00 0.85E+00 3.10E+00 WG 01 46034 12/07/98 Ba-140 -1.16E+00 1.48E+00 5.45E+00 WG 01 46034 12/07/98 Be-7 -1.23E+01 6.37E+00 2.36E+01 ! WG 01 46034 12/07/98 Ce-141 5.31E-02 1.44E+00 4.45E+00 l WG 01 46034 12/07/98 Ce-144 3.75E+00 5.26E+00 1.60E+01 WG 01 46034 12/07/98 Co-57 0.38E+00 0.68E+00 2.08E+00 , WG 01 46034 12/07/98 Co-58 1.38E+00 0.76E+00 2.28E+00 WG 01 46034 12/07/98 Co-60 -0.47E+00 0.82E+00 3.01E+00 ; WG 01 46034 12/07/98 Cr-51 7.36E+00 8.01E+00 2.59E+01 I WG 01 46034 12/07/98 Cs-134 1.75E-02 0.74E+00 2.45E+00 WG 01 46034 12/07/98 Cs-137 -0.42E+00 0.69E+00 2.59E+00 l WG 01 46034 12/07/98 Fe-59 0.91E+00 2.01E+00 7.02E+00 i WG 01 46034 12/07/98 GR-B 3.77E+00 1.07E+00 3.28E+00
- WG 01 46034 12/07/98 H-3 1.11E+00 2.22E+02 7.84E+02 ]
WG 01 46034 12/07/98 I-131 2.98E+00 1.85E+00 5.81E+00 j K-40 1.39E+01 4.70E+01 WG 01 46034 12/07/98 2.10E+01 WG 01 46034 12/07/98 Mn-54 -0.46E+00 0.62E+00 2.22E+00 WG 01 46034 12/07/98 Ru-103 0.11E+00 0.72E+00 2.45E+00 WG 01 46034 12/07/98 Ru-106 2.88E+00 6.44E+00 2.26E+01 WG 01 46034 12/07/98 Sb-124 -0.26E+00 1.74E+00 6.32E+00 WG 01 46034 12/07/98 Se-75 -0.45E+00 1.03E+00 3.47E+00 WG 01 46034 12/07/98 Th-232 0.53E+00 2.53E+00 8.71E+00 1 WG 01 46034 12/07/98 Zn-65 2.42E+00 1.53E+00 4.62E+00 - WG 01 46034 12/07/98 Zr-95 4.04E-02 1.30E+00 4.39E+00 ] 1 1
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I
o I Seabrook Nuclear Power Station Radiological Environmental Monitoring Program l Summary of 1998 Data j l SAMPLE CONC. STD DEV. MDC TYPE STA. LSN l END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WG 13- 41338 03/12/98 Ag-110M -0.67E+00 1.47E+00 5.60E+00 WG 13 41338 03/12/98 Ba-140 -1.72E+00 1.68E+00 7.46E+00 WG 13 41338 03/12/98 Be-7 -3.95E+00 9.84E+00 3.61E+01 WG 13 41338 03/12/98 Ce-141 -0.35E+00 1.95E+00 6.37E+00 WG 13 41338 03/12/98 Ce-144 1.54E+00 7.63E+00 2.41E+01 WG 13 41338 03/12/98 Co-57 -0.50E+00 1.07E+00 3.43E+00 WG 13 41338 03/12/98 Co-58 1.76E+00 1.20E+00 3.72E+00 WG 13 41338 03/12/98 Co-60 8.23E-02 1.34E+00 5.13E+00 WG 13 41338 03/12/98 Cr-51 4.34E+00 1.06E+01 3.60E+01 WG 13 41338 03/12/98 Cs-134 '9.16E-02 1.16E+00 4.00E+00 WG 13 41338 03/12/98 Cs-137 -0.89E+00 1.27E+00 5.02E+00 WG 13 41338 03/12/98 Fe-59 -2.53E+00 2.68E+00 1.20E+01 WG 13 41338 03/12/98 GR-B 3.12E+00 0.42E+00 1.24E+00
- WG 13 41338 03/12/98 H-3 2.61E+02 2.37E+02 7.98E+02 WG 13 41338 03/12/98 I-131 -3.78E+00 2.27E+00 8.68E+00 WG 13 41338 03/12/98 K-40 -4.63E+01 1.75E+01 7.95E+01
. WG 13 41338- 03/12/98 Mn-54 1.76E+00 1.18E+00 3.65E+00 WG 13 41338 03/12/98 Ru-103 -0.69E+00 1.06E+00 4.06E+00 WG 13 41338 03/12/98 Ru-106 5.64E+00 .1.08E+01 3.90E+01 WG 13 41338 03/12/98 Sb-124 -1.07E+00 1.90E+00 9.01E+00 WG . 13 41338 03/12/98 Se-75 -1.65E+00 1.62E+00 5.80E+00 WG 13 41338 03/12/98 Th-232 -2.86E+00 4.36E+00 1.68E+01 WG 13 41338 03/12/98 Zn-65 -1.47E+00 2.87E+00 1.11E+01 WG - 13 41338 03/12/98 Zr-95 0.89E+00 2.15E+00 7.40E+00 WG 13 42597 06/09/98 Ag-110M -0.35E+00 0.96E+00 3.42E+00 WG 13 42597 06/09/98 Ba-140 -1.98E+00 1.38E+00 5.51E+00 WG 13 42597 Of/09/98 Be-7 -2.95E+00 6.91E+00 2.41E+01 WG' 13 42597 06/09/98 Ce-141 2.55E+00 1.30E+00 3.82E+00 WG 13 42597 06/09/98 Ce-144 1.69E+00 4.98E+00 1.53E+01 WG 13 .42597 06/09/98 Co-57 0.74E+00 0.64E+00 1.90E+00 WG 13 42597 06/09/98 Co-58 -0.19E+00 0.88E+00 3.02E+00 WG 13 42597 06/09/98 Co-60 1.84E+00 1.07E+00 3.45E+00 WG 13 42597 06/09/98 Cr-51 -2.72E+00 7.54E+00 2.56E+01 WG 13 42597 06/09/98 Cs-134 1.10E+00 0.78E+00 2.41E+00 WG 13 42597 06/09/98 Cs-137 -0.71E+00 0.91E+00 3.41E+00 WG 13 42597 06/09/98 Fe-59 -1.53E+00 2.40E+00 9.07E+00 WG 13 42597 06/09/98 GR-B 3.22E+00 0.43E+00 1.26E+00
- WG 13 42597 06/09/98 H-3 1.56E+01 2.20E+02 7.74E+02 WG 13 42597 06/09/98 I-131 1.28E+00 1.61E+00 5.24E+00 WG. 13 42597 06/09/98 K-40 1.86E+01 1.48E+01 5.09E+01 WG 13 42597 06/09/98 Mn-54 0.13E+00 0.75E+00 2.55E+00 WG 13 42597 06/09/98 Ru-103 -0.95E+00 0.86E+00 3.09E+00 WG 13 42597 06/09/98 Ru-106 7.66E+00 7.27E+00 2.47E+01 WG 13 42597 06/09/98 Sb-124 3.39E+00 2.17E+00 6.94E+00 WG 13 42597 06/09/98 Se-75 -1.10E+00 1.07E+00 3.67E+00 WG 13 42597 06/09/98 Th-232 -0.20E+00 3.39E+00 1.18E+01 WG 13 42597 06/09/98 Zn-65 1.77E+00 4.13E+00 1.56E+01 WG 13 42597 06/09/98 Zr-95 0.29E+00 1.56E+00 5.22E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
L.
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WG 13 44174 09/10/98 Ag-110M 8.99E-02 1.35E+00 4.90E+00 WG 13 44174 09/10/98 Ba-140 2.55E+00 1.37E+00 4.10E+00 WG 13 44174 09/10/98 Be-7 -2.59E+00 7.75E+00 2.82E+01 WG 13 44174 09/10/98 Ce-141 -3.57E+00 1.88E+00 6.45E+00 WG 13 44174 09/10/98 Ce-144 2.59E+00 6.88E+00 2.14E+01 WG 13 44174 09/10/98 Co-57 0.92E+00 0.91E+00 2.76E+00 WG 13 44174 09/10/98 Cv-58 0.65E+00 0.94E+00 3.13E+00 WG 13 44174 09/10/98 Co-60 1.63E+00 0.95E+00 2.87E+00 WG 13 44174 09/10/98 Cr-51 -3.21E+00 9.54E+00 3.34E+01 WG 13 44174 09/10/98 Cs-134 1.15E+00 0.89E400 2.78E+00 WG 13 44174 09/10/98 Cs-137 -0.82E+00 1.13E+00 4.34E+00 WG 13 44174 09/10/98 Fo-59 0.46E+00 2.87E+00 1.03E+01
'WG 13 44174 09/10/98 GR-B 5.94E+00 0.51E+00 1.40E+00
- WG 13 44174 09/10/98 H-3 -3.05E+02 1.79E+02 6.58E+02 WG 13 44174 09/10/98 I-131 -1.35E+00 2.04E+00 7.26E+00 WG 13 44174 09/10/98 K-40 -2.70E+00 1.68E+01 6.06E+01 WG 13 44174 09/10/98 Mn-54 0.23E+00 0.84E+00 2.93E+00 WG 13 44174 09/10/98 Ru-103 -0.87E+00 1.09E+00 4.04E+00 WG 13 44174 09/10/98 Ru-106 -9.71E+00 8.21E+00 3.33E+01 WG 13 44174 09/10/98 Sb-124 -5.93E-02 2.32E+00 9.06E+00 WG 13 44174 09/10/98 Se-75 0.18E+00 1.25E+00 4.24E+00 WG 13 44174 09/10/98 Th-232 -0.55E+00 3.82E+00 1.41E+01 WG 13 44174 09/10/98 Zn-65 -4.52E+00 2.35E+00 9.70E+00 WG 13 44174 09/10/98 Zr-95 2.49E+00 1.52E+00 4.62E+00 WG 13 46035 12/07/98 Ag-110M 0.38E+00 0.92E+00 3.16E+00 WG 13 46035 12/07/98 Ba-140 0.56E+00 1.02E+00 3.65E+00
, WG 13 46035 12/07/98 Be-7 1.66E+00 5.65E+00 1.91E+01 WG 13 46035 12/07/98 Ce-141 -0.26E+00 1.38E+00 4.41E+00 WG 13 46035 12/07/98 Ce-144 -1.59E+00 4.73E+00 1.48E+01 WG 13 46035 12/07/98 Co-57 0.17E+00 0.59E+00 1.82E+00 WG 13 46035 12/07/98 .Co-58 -0.74E+00 0.66E+00 2.40E+00 WG 13 46035 12/07/98 Co-60 0.29E+00 0.68E+00 2.32E+00 WG 13 46035 12/07/98 Cr-51 0.29E+00 7.38E+00 2.47E+01 WG 13 46035 12/07/98 Cs-134 -1.04E+00 0.66E+00 2.35E+00 WG 13 46035 12/07/98 Cs-137 -0.16E+00 0.71E+00 2.58E+00 WG 13 46035 12/07/98 Fe-59 -1.52E+00 1.70E+00 6.49E+00 WG 13 46035 12/07/98 GR-B 2.80E+00 0.56E+00 1.70E+00
- WG '13 46035 12/07/98 H-3 1.79E+02 2.27E+02 7.75E+02 WG 13 46035 12/07/98 I-131 -1.06E+00 1.65E+00 5.74E+00 WG 13 46035 12/07/98 K-40 -1.57E+01 1.14E+01 4.33E+01 WG. 13 46035 12/07/98 Mn-54 -0.17E+00 0.60E+00 2.08E+00 WG 13 46035 12/07/98 Ru-103 -0.99E+00 0.85E+00 3.04E+00 WG 13 46035 12/07/98 Ru-106 -4.81E+00 5.71E+00 2.16E+01 WG 13 46035 12/07/98 Sb-124 2.25E+00 1.56E+00 5.07E+00 WG 13 46035 12/07/98 Se-75 0.19E+00 0.95E+00 3.14E+00 WG 13 46035 12/07/98 Th-232 -2.43E+00 2.59E+00 9.60E+00 WG 13 46035 12/07/98 Zn-65 -1.24E+00 1.36E+00 5.15E+00 WG 13 46035 12/07/98 Zr-95 1.57E+00 1.24E+00 3.88E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
L . .. ..
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV, MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) Sea Water WS 01 40573 01/22/98 Ag-110M -0.64E+00 1.04E+00 3.84E+00 WS 01 40573 01/22/98 Ba-140 -2.96E+00 2.35E+00 9.34E+00 WS 01 40573 01/22/98 Be-7 1.48E+01 7.84E+00 2.43E+01 WS 01 40573 01/22/98 Ce-141 -3.90E+00 1.9I -10 6.43E+00 WS 01 40573 01/22/98 Ce-144 -3.08E+00 5.46h+00 1.73E+01 WS 01 40573 01/22/98 Co-57 1.10E+00 0.75E+00 2.23E+00 WS 01 40573 01/22/98 Co-58 2.92E-02 0.82E+00 2.80E+00 WS 01 40573 01/22/98 Co-60 -2.72E-02 0.80E+00 2.85E+00 WS 01 40573 01/22/98 Cr-51 1.26E+01 1.04E+01 3.34E+01 WS 01 40573 01/22/98 Cs-134 -0.12E+00 0.68E+00 2.33E+00 WS 01 40573 01/22/98 Cs-137 -0.79E+00 0.79E+00 3.02E+00 WS 01 40573 01/22/98 Fe-59 3.80E+00 2.59E+00 8.16E+00 WS 01 40573 01/22/98 I-131 2.18E+00 4.07E+00 1.34E+01 WS 01 40573 01/22/98 K-40 2.95E+02 2.43E+01 4.98E+01
- WS 01 40573 01/22/98 Mn-54 -0.44E+00 0.74E+00 2.62E+00 WS 01 40573 01/22/98 Tu 103 -1.58E+00 0.98E+00 3.67E+00 WS 01 40573 01/22/98 Ru-106 1.02E+01 7.41E+00 2.47E+01 WS 01 40573 01/22/98 Sb-124 1.66E+00 1.94E+00 6.72E+00 WS 01 40573 01/22/98 Se-75 -0.77E+00 1.19E+00 4.04E+00 WS 01 40573- 01/22/98 Th-232 0.33E+00 3.38E+00 1.18E+01 WS 01 40573 01/22/98 Zn-65 4.62E+00 4.04E+00 1.54E+01 WS 01 40573 01/22/98 Zr-95 -0.20E+00 1.31E+00 4.59E+00 WS 01 40886 02/17/98 Ag-110M -1.80E+00 1.19E+00 4.82E+00 WS 01 40886 02/17/98 Ba-140 0.71E+00 1.59E+00 5.68E+00 WS 01 40886 02/17/98 Be-7 -1.13E+01 8.18E+00 3.15E+01 WS 01 40886 02/17/98 Ce-141 0.49E+00 1.78E+00 5.59E+00 WS 01 40886 02/17/98 Ce-144 4.77E+00 6.91E+00 2.13E+01 WS 01 40886 02/17/98 Co-57 9.85E-02 0.86E+00 2.72E+00 WS 01 40886 02/17/98 Co-58 -1.62E+00 0.95E+00 3.82E+00 WS 01 40886 02/17/98 Co-60 -0.94E+00 0.78E+00 3.51E+00 WS 01 40886 02/17/98 Cr-51 -4.75E+00 1.01E+01 3.54E+01 WS 01 40886 02/17/98 Cs-134 -0.10E+00 0.85E+00 3.01E+00 WS 01 40886 02/17/98 Cs-137 -1.36E+00 1.20E+00 4.70E+00 WS 01 40886 02/17/98 Fe-59 0.30E+00 2.93E+00 1.08E+01 WS 01 40886 02/17/98 I-131 -7.90E-02 2.11E+00 7.27E+00 WS 01 40886 02/17/98 K-40 3.26E+02 3.17E+01 5.79E+01
- WS 01 40886 02/17/98 Mn-54 0.82E+00 0.94E+00 3.09E+00 WS 01 40886 02/17/98 Ru-103 5.11E-02 0.97E+00 3.45E+00 WS 01 40886 02/17/98 Ru-106 8.58E+00 1.01E+01 3.51E+01 WS 01 _40886 02/17/98 Sb-124 0.74E+00 1.93E+00 7.28E+00 l WS 01 40886 02/17/98 Se-75 0.71E+00 1.48E+00 4.90E+00 WS 01 40886 02/17/98 Th-232 -1.94E+00 3.85E+00 1.43E+01 WS 01 40886 02/17/98 Zn-65 0.99E+00 2.41E+00 8.51E+00 WS 01 '40886 02/17/98 Zr-95 0.70E+00 1.85E+00 6.28E+00
- Radioactivity detected'in sample (i.e., CONC > 3 STD. DEV.)
1 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE_ (pCi/kg) (pCi/kg) (pCi/kg) WS 01 41519 03/24/98 Ag-110M -0.86E+00 0.98E+00 3.54E+00 WS 01 41519 03/24/98 Ba-140 5.62E+00 2.35E+00 6.80E+00 ! WS 01 41519 03/24/98 Be-7 -5.89E+00 7.44E+00 2.60E+01 WS 01 41519 03/24/98 Ce-141 -1.92E+00 1.38E+00 4.41E+00 WS 01 41519 03/24/98 Ce-144 -1.29E+00 4.39E+00 1.37E+01 WS 01 41519 03/24/98 Co-57 0.63E+00 0.60E+00 1.79E+00 WS 01 41519 03/24/98 Co-58 0.61E+00 0.83E+00 2.71F 00 WS 01 41519 03/24/98 Co-60 1.08E+00 1.01E+00 3.44E>00 WS 01 41519 03/24/98 Cr-51 -3.71E+00 8.57E+00 2.91E+01 l WS 01 41519 03/24/98 Cs-134 -1.17E+00 0.74E+00 2.81E+00 ' WS 01 41519 03/24/98 Cs-137 0.18E+00 0.71E+00 2.54E+00 WS 01 41519 03/24/98 Fe-59 1.37E+00 2.76E+00 9.51E+00 WS 01 41683 03/24/98 H-3 6.34E+01 2.39E+02 8.31E+02 WS 01 41519 03/24/98 I-131 -3.02E+00 3.09E+00 1.07E+01 WS 01 41519 03/24/98 K-40 3.13E+02 2.41E+01 4.53E+0'
- WS 01 41519 03/24/98 Mn-54 4.74E-02 0.77E+00 3.60E+00 WS 01 41519 03/24/98 Ru-103 -0.27E+00 0.90E+00 3.10E+00 ;
WS 01 41519 03/24/98 Ru-106 6.29E+00 7.41E+00 2.53E+01 ! WS 01 41519 03/24/98 Sb-124 -3.87E+00 2.26E+00 9.36E+00 l WS 01 41519 03/24/L8 Se-,5 0.62E+00 1.02E+00 3.33E+00 ; WS 01 41519 03/24/98 Th-232 4.43E+00 3.23E+00 1.03E+01 WS 01 41519 03/24/98 Zn-65 -2.15E+00 1.80E+00 6.81E+00 WS 01 41519 03/24/98 Zr-95 0.14E+00 1.45E+00 4.87E+00 WS 01 41899 04/21/98 Ag-110M -2.40E+00 1.19E+00 5.10E+00 WS 01 41899 04/21/98 Ba-140 1.40E+00 1.71E+00 5.95E+00 WS 01 41899 04/21/98 Be-7 -8.01E+00 8.30E+00 3.09E+01 WS 01 41899 04/21/98 Ce-141 -1.87E+00 1.77E+00 5.81E+00 WS 01 41899 04/21/98 Ce-144 -1.05E+01 6.48E+00 2.18E+01 WS 01 41899 04/21/98 Co-57 0.28E+00 0.81E+00 2.55E+00 WS 01 41899 04/21/98 Co-58 1.632+00 0.99E+00 3.01E+00 WS 01 41899 04/21/98 Co-60 0.26E+00 0.91E+00 3.31E+00 WS 01 41899 04/21/98 Cr-51 -1.23E+01 9.84E+00 3.58E+01 WS 01 41899 04/21/98 Cs-134 -0.56E+00 0.90E+00 3.24E+00 WS 01 41899 04/21/98 Cs-137 0.16E+00 0.92E+00 3.41E+00 WS 01 41899 04/21/98 Fe-59 2.88E+00 2.63E+00 8.68E+00 WS 01 41899 04/21/98 I-131 -0.70E+00 2.09E+00 7.34E+00 WS 01 41899 04/21/98 K-40 2.71E+32 2.99E+01 6.41E+01
- WS 01 41899 04/21/98 Mn-54 -0.65E+00 1.00E+00 3.65E+00 WS 01 41899 04/21/98 Ru-103 -0.27E+00 1.00E+00 3.59E+00 WS 01 41899 04/21/98 Ru-106 -6.76E+00 1.02E+01 3.87E+01 WS 01 41899 04/21/98 Sb-124 0.84E+00 1.67E+00 6.45E+00 WS 01 41899 04/21/98 Se-75 -2,18E+00 1.29E+00 4.72E+00 WS 01 41899 04/21/98 Th-232 4.19E+00 3.93E+00 1.32E+01 WS 01 41899 04/21/98 Zn-65 0.59E+00 2.30E+00 8.20E+00 WS 01 41899 04/21/98 Zr-95 -).67E+00 1.84E+00 6.58E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
l L
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) - (pCi/kg) (pci/kg) WS 01 42274 05/18/98 Ag-110M -1.69E+00 1.40E+00 5.91E+00 WS 01 42274 05/18/98 Ba-140 1.95E+00 2.10E+00 7.20E+00 WS 01 42274 05/18/98 Be-7 3.44E+00 9.62E+00 3.39E+01 WS Ol' 42274 05/18/98 Ce-141 -1.69E+00 2.00E+00 6.66E+00 WS 01 42274 05/18/98 Ce-144 0.44E+00 7.48E+00 2.37E+01 WS 01 42274 05/18/98 Co-57 1.12E+00 1.00E+00 3.03E+00 WS 01 42274 05/18/98 Co-58 -1.22E+00 1.18E+00 4.73E+00 WS 01 42274 05/18/98 Co-60 -2.61E+00 1.71E+00 7.50E+00 WS 01 42274 05/18/98 Cr-51 -2.93E+00 1.07E+01 3.80E+01 WS 01 42274 05/18/98 Cs-134 0.81E+00 1.11E+00 3.51E+00 WS 01 42274 05/18/98 Cs-137 0.00E+00 1.40E+00 5.26E+00 WS 01 42274 05/18/98 Fe-59 -1.73E+00 3.65E+00 1.49E+01 WS 01 42274 05/18/98 I-131 -0.27E+00 2.20E+00 7.82E+00 WS 01 42274 05/18/98 K-40 2.93E+02 4.04E+01 8.71E+01
- WS 01 42274 05/18/98 Mn-54 -0.90E+00 1.30E+00 4.93E+00 WS 01 42274 05/18/98 Ru-103 -0.47E+00 1.24E+00 4.60E+00 WS 01 42274 05/18/98 Ru-106 0.00E+00 1.24E+01 4.64E+01 WS 01 42274 05/18/98 Sb-124 -3.14E+00 3.55E+00 1.55E+01 WS 01 42274 05/18/98 Se-75 3.92E+00 1.65E+00 4.96E+00 WS 01 42274 05/18/98 Th-232 1.23E+00 5.24E+00 1.87E+01 WS 01 42274 05/18/98 Zn-65 2.23E+00 3.00E+00 1.05E+01 WS 01 42274 05/18/98 Zr-95 1.97E+00 2.14E+00 7.07E+00 WS 01 42824 06/22/98 Ag-110M 0.82E+00 2.09E+00 7.30E+00 WS. 01 42824 06/22/98 Ba-140 2.07E+00 2.02E+00 6.99E+00 WS 01 42824 06/22/98 Be-7 -0.70E+00 1.21E+01 4.37E+01 WS 01 42824 06/22/98 Ce-141 -2.65E+00 2.19E+00 7.49E+00 WS 01 42824 06/22/98 Ce-144 -3.69E+00 8.15E+00 2.67E+01 WS 01 42824 06/22/98 Co-57 -0.82E+00 1.08E+00 3.56E+00 WS 01 42824 06/22/98 Co-58 0.16E+00 1.61E+00 5.73E+00 WS 01 42824 06/22/98 Co-60 -0.45E+00 1.62E+00 6.73E+00 WS 01 42824 06/22/98 Cr-51 -1.50E+01 1.31E+01 4.90E+01 WS 01 42824 06/22/98 Cs-134 0.24E+00 1.62E+00 5.56E+00 WS 01 42824 06/22/98 Cs-137 1.48E+00 1.36E+00 4.70E+00 WS 01 42824 06/22/98 Fe-59 -5.51E+00 3.96E+00 1.81E+01 WS 01 43129 06/22/98 H-3 9.66E+01 2.25E+02 7.80E+02 WS 01 42824 06/22/98 I-131 3.59E+00 2.98E+00 9.64E+00 WS 01 42824 06/22/98 K-40 2.53E+02 4.17E+01 9.44E+01
- WS 01 42824 06/22/98 Mn-54 -2.80E+00 1.48E+00 6.16E+00 WS 01 42824 06/22/98 Ru-103 2.35E+00 1.63E+00 5.21E+00 WS 01 42824 06/22/98 Ru-106 1.49E+01 1.36E+01 4.68E+01 WS 01 42824 06/22/98 Sb-124 4.18E+00 3.94E+00 1.36E+01 WS 01 42824 06/22/98 Se-75 1.76E+00 1.96E+00 6.41E+00 WS 01 42824 06/22/98 Th-232 0.30E+00 5.29E+00 1.97E+01 WS 01 42824 06/22/98 Zn-65 -8.90E+00 6.72E+00 2.65E+01 WS 01 42824 06/22/98 Zr-95 -0.98E+00 2.55E+00 9.59E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
e' l l 1 i Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WS 01 43216 07/20/98 Ag-110M 1.35E+00 1.31E+00 4.37E+00 WS 01 43216 07/20/98 Ba-140 -2.34E+00 1.50E+00 6.41E+00 WS 01 43216 07/20/98 Be-7 -4.89E+00 7.89E+00 2.85E+01 WS 01 43216 07/20/98 Ce-141 -1.32E+00 1.92E+00 6.24E+00 WS 01 43216 07/20/98 Ce-144 3.10E+00 6.38E+00 1.97E+01 WS 01 43216 07/20/98 Co-57 -0.30E+00 0.84E+00 2.68E+00 WS 01 43216 07/20/98 Co-58 -1.21E+00 0.84E+00 3.26E+00 WS 01 43216 07/20/98 Co-60 -0.41E+00 0.94E+00 3.56E+00 WS 01 43216 07/20/98 Cr-51 1.69E+00 9.67E+00 3.26E+01 WS 01 43216 07/20/98 Cs-134 -1.73E+00 0.93E+00 3.44E+00 WS 01 43216 07/20/98 Cs-137 0.82E+00 0.97E+00 3.36E+00 WS 01 43216 07/20/98 Fe-59 -2.39E+00 2.73E+00 1.05E+01 WS 01 43216 07/20/98 I-131 -0.97E+00 1.96E+00 6.88E+00 WS 01 43216 07/20/98 K-40 2.81E+02 2.78E+01 5.74E+01
- WS 01 43216 07/20/98 Mn-54 0.74E+00 0.84E+00 2.74E+00 WS 01 43216 07/20/98 Ru-103 -1.53E+00 1.10E+00 4.10E+00 WS 01 43216 07/20/98 Ru-106 -2.32E+00 8.03E+00 3.01E+01 WS 01 43216 07/20/98 Sb-124 3.81E+00 2.44E+00 7.78E+00 WS 01 43216 07/20/98 Se-75 0.34E+00 1.37E+00 4.57E+00 WS 01 43216 07/20/98 Th-232 1.11E+00 3.39E+00 1.20E+01 WS 01 43216 07/20/98 Zn-65 4.94E+00 5.14E+00 1.97E+01 WS 01 43216 07/20/98 Zr-95 1.28E+00 1.65E+00 5.40E+00 WS 01 43549 08/17/98 Ag-110M 1.26E+00 1.66E+00 5.91E+00 WS 01 43549 08/17/98 Ba-140 -1.46E+00 2.25E+00 9.66E+00 WS 01 43549 08/17/98 Be-7 9.12E+00 1.26E+01 4.29E+01 WS 01 43549 08/17/98 Ce-141 2.75E+00 2.59E+00 , 7.91E+00 WS 01 43549 08/17/98 Ce-144 7.11E+00 1.05E+01" 3.27E+01 WS 01 43549 08/17/98 Co-57 -0.52E+00 1.25E+00 4.12E+00 s2 01 43549 08/17/98 Co-58 0.64E+00 1.35E+00 4.73E+00 Wd 01 43549 08/17/98 Co-60 1.07E+00 1.55E+00 5.46E+00 WS 01 43549 08/17/98 Cr-51 -2.30E+01 1.34E+01 5.23E+01 WS 01 43549 08/17/98 Cs-134 -0.56E+00 1.43E+00 5.17E+00 WS 01 43549 08/17/98 Cs-137 -1.80E+00 1.47E+00 6.22E+00 WS 01 43549 08/17/98 Fe-59 -6.71E+00 5.09E+00 2.07E+01 WS 01 43549 08/17/98 I-131 1.29E+00 2.71E+00 9.33E+00 WS 01 43549 08/17/98 K-40 2.42E+02 4.30E+01 1.10E+02
- WS 01 43549 08/17/98 Mn-54 -1.83E+00 1.37E+00 5.58E+00 WS 01 43549 08/17/98 Ru-103 0.68E+00 1.38E+00 4.85E+00 WS 01 43549 08/17/98. Ru-106 -2.28E+01 1.37E+01 5.83E+01 WS 01 43549 08/17/98 Sb-124 -1.52E+00 3.24E+00 1.41E+01 WS 01 43549 08/17/98 Se-75 1.92E+00 1.92E+00 6.28E+00 WS 01 43549 08/17/98 Th-232 -0.29E+00 6.14E+00 2.29E+01 WS 01 43549 08/17/98 Zn-65 3.34E+00 7.30E+00 2.72E+01 j WS 01 43549 08/17/98 Zr-95 -1.80E+00 2.58E+00 9.92E+00 I
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
L .. .J
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WS 01 44381 09/22/98 Ag-110M -1.82E+00 1.20E+00 4.89E+00 WS 01 44381 09/22/98 Ba-140 2.69E+00 1.63E+00 4.95E+00 WS 01 44381 09/22/98 Be-7 1.43E+01 9.05E+00 2.85E+01 WS 01 44381 09/22/98 Ce-141 -3.03E+00 1.75E+00 5.95E+00 WS 01 44381 09/22/98 Ce-144 1.81E+00 6.36E+00 1.99E+01 WS 01 44381 09/22/98 Co-57 -0.52E+00 0.82E+00 2.65E+00 l WS 01 44381 09/22/98 Co-58 -1.80E+00 0.89E+00 3.72E+00 WS 01 44381 09/22/98 Co-60 3.06E-02 0.95E+00 3.66E+00 WS 01 44381 09/22/98 Cr-51 -6.45E+00 1.05E+01 3.68E+01 WS 01 44381 09/22/98 Cs-134 2.05E+00 1.27E+00 3.55E+00 WS 01 44381 09/22/98 Cs-137 -1.00E+00 0.97E+00 3.91E+00 WS 01 44381 09/22/98 Fe-59 1.54E+00 2.93E+00 1.05E+01 WS 01 45327 09/22/98 H-3 4.60E+02 2.38E+02 7.71E+02 WS 01 44381 09/22/98 I-131 2.16E+00 2.44E+00 7.98E+00 WS 01 44381 09/22/98 K-40 2.66E+02 3.14E+01 6.86E+01
- WS 01 44381 09/22/98 Mn-54 -1.69E+00 0.92E+00 3.73E+00 WS 01 44381 09/22/98 Ru-103 -2.32E+00 1.15E+00 4.48E+00 WS 01 44381 09/22/98 Ru-106 -2.18E+00 9.68E+00 3.61E+01 WS 01 44381 09/22/98 Sb-124 0.81E+00 2.12E+00 8.00E+00 WS 01 44381 09/22/98 Se-75 0.68E+00 1.43E+00 4.74E+00 WS 01 44381 09/22/98 Th-232 -0.40E+00 4.51E+00 1.59E+01 WS 01 44381 09/22/98 Zn-65 -1.60E+00 1.99E+00 7.61E+00 WS 01 44381 09/22/98 Zr-95 -2.38E+00 1.64E+00 6.51E+00 WS 01 45258 10/20/98 Ag-110M -0.54E+00 1.47E+00 5.61E+00 WS 01 45258 10/20/98 Ba-140 -2.03E+00 1.81E+00 7.68E+00 WS 01 45258 10/20/98 Be-7 -0.92E+00 1.05E+01 3.70E+01 WS 01 45258 10/20/98 Ce-141 -2.38E+00 2.24E+00 7.48E+00 WS 01 45258 10/20/98 Ce-144 -0.22E+00 7.65E+00 2.44E+01 WS 01 45258 10/20/98 Co-57 0.17E+00 1.02E+00 3.20E+00 WS 01 45258 10/20/98 Co-58 0.79E+00 1.02E+00 3.40E+00 WS 01 45258 10/20/98 Co-60 1.57E+00 1.38E+00 4.51E+00 WS 01 45258 10/20/98 Cr-51 -9.85E+00 1.13E+01 4.08E+01 WS 01 45258 10/20/98 Cs-134 0.90E+00 1.09E+00 3.55E+00 WS 01 45258 10/20/98 Cs-137 -1.08E+00 1.11E+00 4.47E+00 WS 01 45258 10/20/98 Fe-59 3.47E+00 3.58E+00 1.19E+01 WS 01 45258 10/20/98 I-131 -0.28E+00 2.21E+00 7.73E+00 i WS 01 45258 10/20/98 K-40 3.40E+02 3.61E+01 7.34E+01
- l WS 01 45258 10/20/98 Mn-54 0.70E+00 1.04E+00 3.50E+00 WS 01 45258 10/20/98 Ru-103 -1.04E+00 1.28E+00 4.77E+00 WS 01 45258 10/20/98 Ru-106 8.32E+00 9.56E+00 3.35E+01 WS 01 45258 10/20/98 Sb-124 -1.07E+00 1.89E+00 8.59E+00 WS 01 45258 10/20/98 Se-75 -2.97E+00 1.42E+00 5.37E+00 WS 01 45258 10/20/98 Th-232 -5.83E+00 4.11E+00 1.68E+01 WS 01 45258 10/20/98 Zn-65 5.99E+00 5.53E+00 2.12E+01 WS 01 45258 10/20/99 Zr-95 0.18E+00 1.97E+00 6.91E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
L
I Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC
' TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) i l WS 01 45727 11/16/98 Ag-110M 4.35E+00 1.98E+00 5.72E+00 WS 01 457.'7 11/16/98 Ba-140 -2.74E+00 2.13E+00 8.84E+00 WS 01 45727 11/16/98 Be-7 4.82E+00 1.09E+01 3.71E+01 WS 01 45727 11/16/98 Ce-141 -2.34E+00 2.06E+00 6.76E+00 WS 01 45727 11/16/98 Ce-144 7.01E+00 8.16E+00 2.48E+01 WS 01 45727 11/16/98 Co-57 0.20E+00 1.00E+00 3.11E+00 WS 01 45727 11/16/98 Co-58 2.59E+00 1.43E+00 4.28E+00 WS 01 45727 11/16/98 Co-60 3.08E+00 1.57E+00 4.90E+00 l WS- 01 45727 11/16/98 Cr-51. 0.39E+00 1.25E+01 4.23E+01 WS 01 45727 11/16/98 Cs-134 -0.44E+00 1.15E+00 4.04E+00 WS 01 45727 11/16/98 Cs-137 -1.01E+00 1.47E+00' 5.58E+00 WS 01 45727 11/16/98 Fe-59 -3.91E+00 3.37E+00 1.41E+01 WS 01 45727 11/16/98 I-131 -0.52E+00 2.46E+00 8.50E+00 WS 01 45727 11/16/98 K-40 3.25E+02 3.73E+01 7.61E+01
- i WS 01 45727 11/16/98 Mn-54 0.98E+00 1.02E+00 3.36E+00 l~ WS 01 45727 11/16/98 Ru-103 -2.28E+00 1.32E+00 5.07E+00 l WS 01 .45727 11/16/98 Ru-106 6.62E+00 1.17E+01 4.14E+01 l WS 01 45727 11/16/98 Sb-124 3.00E+00 3.21E+00 1.12E+01 WS 01 45727 11/16/98 Se-75 -4.75E-02 1.76E+00 5.91E+00 WS 01 45727 11/16/98 Th-232 -0.20E+00 5.70E+00 1.99E+01
'WS 01 45727 11/16/98 Zn-65 -1.44E+00 7.32E+00 2.76E+01 WS .01 45727 11/16/98 Zr-95 1.76E+00 2.35E+00 7.72E+00 l ~
l t
~
- Radioactivity detected in sample (i . e . , CONC > 3 STD. DEV. )
i k
Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC rYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) WS 01 46239 12/14/98 Ag-110M 0.98E+00 1.57E+00 5.20E+00 WS 01 461:S 12/14/98 Ba-140 -1.78E+00 1.71E+00 7.10E+00 WS 01 46238 12/14/98 Be-7 1.52E+00 8.78E+00 3.03E+01 WS 01 46238 12/14/98 Ce-141 -0.81E+00 1.74E+00 5.57E+00 WS 01 46238 12/14/98 Ce-144 -4.29E+00 6.12E+00 1.96E+01 WS 01 46238 12/14/98 Co-57 -1.01E+00 0.78E+00 2.54E+00 i WS' 01 46238 12/14/9F Co-58 -0.85E+00 1.03E+00 3.84E+00 WS 01 46238 12/14/98 Co-60 -2.04E+00 1.53E+00 6.00E+00 WS 01 46238 12/14/98 Cr-51 -1.15E+01 1.03E+01 3.67E+01 WS 01 46238 12/14/98 Cs-134 -6.58E-02 0.79E+00 2.65E+00 WS 01 46238 12/14/98 Cs-137 1.20E+00 1.12E+00 3.84E+00 WS 01 46238 12/14/98 Fe-59 -7.93E-02 3.14E+00 1.17E+01 WS 01 47068 12/14/98 H-3 -2.02E+02 2.38E+02 8.64E+02 WS 01 46238 12/14/98 I-131 2.38E+00 2.28E+00 7.38E+00 WS 01 46238 12/14/98 K-40 3.07E+02 3.28E+01 6.83E+01
- WS 01 46238 12/14/98 Mn-54 -0.68E+00 1.04E+00 3.80E+00 WS 01 46238 12/14/98 Ru-103 -0.46E+00 1.11E+00 3.97E+00 WS 01 46238 12/14/98 Ru-106 -5.41E+00 9.76E+00 3.70E+01 WS 01 46238 12/14/98 Sb-124 5.63E+00 2.43E+00 6.34E+00 WS 01 46238 12/14/98 Se-75 -1.16E+00 1.26E+00 4.44E+00 WS 01 46238 12/14/98 Th-232 1.16E+01 4.27E+00 1.18E+01 WS 01 46238 12/14/98 Zn-65 -1.70E+00 2.53E+00 9.63E+00 WS 01 46238 12/14/98 Zr-95 2.76E+00 1.91E+00 6.35E+00 1
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
I 1 Seabrook Nuclear Power Station Radiological Environmental Monitoring Program , Summary of 1998 Data j i SAMPLE CONC. STD DEV. MDC l TYPE STA. LSN END DATE NUCLIDE fpCi/kg) (pCi/kg) (pCi/kg) )
]
WS 51 40574 02/22/98 Ag-110M -0.83E+00 0.80E+00 2.90E+00 WS 51 40574 01/22/98 Ba-140 ~1.51E+00 2.03E+00 7.46E+00 WS 51 40574 01/22/98 Be-7 -7.60E+00 6.60E+00 2.32E+01 l WS 51 40574 01/22/98 Ce-141 -1.68E+00 1.45E+00 4.63E+00 ) WS 51 40574 01/22/98 Ce-144 3.91E+00 4.25E+00 1.28E+01 ! WS 51 40574 01/22/98 Co-57 0.48E+00 0.54E+00 1.62E+00 l WS 51 40574 01/22/98 Co-58 -1.36E+00 0.68E+00 2.54E+00 ! WS 51 40574 01/22/98 Co-60 -0.64E+00 0.67E+00 2.55E+00 WS 51 40574 01/22/98 Cr-51 9.10E+00 8.62E+00 2.76E+01 WS 51 40574 01/22/98 Cs-134 -0.63E+00 0.65E+00 2.33E+00 WS 51 40574 01/22/98 Cs-137 -0.14E+00 0.75E+00 2.68E+00 WS 51 40574 01/22/98 Fe-59 -2.90E+00 2.72E+00 9.99E+00 WS 51 40574 01/22/98 I-131 0.60E+00 3.32E+00 1.10E+01 WS 51 40574 01/22/98 K-40 3.38E+02 2.27E+01 4.72E+01 * , WS 51 40574 01/22/98 Mn-54 0.40E+00 0.64E+00 2.08E+00 ' WS 51 40574 01/22/98 Ru-103 0.27E+00 0.84E+00 2.81E+00 WS 51 40574 01/22/98 Ru-106 -3.55E+00 6.27E+00 2.28E+01 WS 51 40574 01/22/98 Sb-124 -0.68E+00 1.56E+00 5.89E+00 WS 51 40574 01/22/98 Se-75 -0.34E+00 0.94E+00 3.12E+00 WS 51 40574 01/22/98 Th-232 -1.50E+00 2.63E+00 9.17E+00 WS 51 40574 01/22/98 Zn-65 -0.94E+00 1.82E+00 6.43E+00 WS 51 40574 01/22/98 Zr-95 0.94E+00 1.32E+00 4.25E+00 WS 51 40887 02/17/98 Ag-110M 0.81E+00 1.25E+00 4.24E+00 WS 51 40887 02/17/98 Ba-140 -1.20E+00 1.54E+00 6.22E+00 WS 51 40887 02/17/98 Be-7 -1.84E+00 7.75E+00 2.81E+01 WS 51 40887 02/17/98 Ce-141 0.69E+00 1.72E+00 5.37E+00 l WS 51 40887 02/17/98 Ce-144 9.92E+00 6.97E+00 2.08E+01 ; WS 51 40887 02/17/98 Co-57 0.30E+00 0.89E+00 2.77E+00 l WS 51 40887 02/17/98 Co-58 0.54E+00 0.88E+00 3.01E+00 WS 51 40887 02/17/98 Co-60 0.95E+00 1.16E+00 4.00E+00 WS 51 40887 02/17/98 Cr-51 4.58E+00 9.77E+00 3.28E+01 WS 51 40887 02/17/98 Cs-134 -0.70E+00 1.04E+00 3.88E+00 WS 51 40887 02/17/98 Cs-137 0.17E+00 1.00E+00 3.71E+00 WS 51 40887 02/17/98 Fe-59 1.27E+00 2.60E+00 9.41E+00 WS 51 40887 02/17/98 I-131 -0.40E+00 1.79E+00 6.35E+00 WS 51 40887 02/17/98 K-40 2.70E+02 2.99E+01 6.06E+01
- WS- 51 40887 02/17/98 Mn-54 -0.82E+00 0.82E+00 3.22E+00 WS 51 40887 02/17/98 Ru-103 -0.86E+00 0.99E+00 3.72E+00 WS 51 40887 02/17/98 Ru-106 -1.74E+00 1.08E+01 3.99E*01 j WS 51 40887 02/17/98 Sb-124 -0.86E+00 1.96E+00 8.15E+00 1 WS 51 40re' 02/17/98 Se-75 1.19E+00 1.47E+00 4.81E+00 )
WS 51 4;t?* 02/17/98 Th-232 -2.59E+00 3.79E+00 1.43E+01 l WS 51 40:>/ 02/17/98 Zn-65 0.68E+00 2.50E+00 8.89E+00 I WS 51 40887 02/17/98 Zr-95 -0.62E+00 1.70E+00 6.18E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.) j I
l t ;
F l Seabrook Nuclear Power Station ' Radiological Environmental Monitoring Program Summary of 1998 Data
- SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
WS 51 41520 03/24/98 Ag-110M 0.38E+00 1.03E+00 3.4?E+00 WS 51 41520 03/24/98 Ba-140 -3.21E+00 1.81E+00 7.86E+00 WS 51 41520 03/24/98 Be-7 -1.38E+00 8.20E+00 2.80E+01 WS 51 41520 03/24/98 Ce-141 -1.01E+00 1.43E+00 4.51E+00 WS 51 41520 03/24/98 Ce-144 6.38E+00 4.99E+00 1.49E+01 dS 51 41520 03/24/98 Co-57 9.96E-02 0.62E+00 1.91E+00 WS 51 41520 03/24/98 Co-58 0.81E+00 0.85E+00 2.72E+00 WS 51 41520 03/24/98 Co-60 1.47E+00 0.38E+00 2.78E+00 WS 51 41520 03/24/98 Cr-51 3.54E+00 9.23E+00 3.04E+01 WS 51 41520 03/24/98 Cs-134 -0.48E+00 0.70E+00 2.48E+00 WS 51 41520 03/24/98 Cs-137 0.68E+00 0.81E+00 2.81E+00 WS 51 41520 03/24/98 Fe-59 -1.60E+00 2.66E+00 1.00E+01 WS 51 41684 03/24/98 H-3 6.39E+01 2.41E+02 8.38E+02 WS 51 41520 03/24/98 I-131 -0.49E+00 3.41E+00 1.15E+01 WS 51 41520 03/24/98 K-40 2.50E+02 2.55E+01 6.19E+01
- WS 51 41520 03/24/98 Mn-54 -5.16E-02 0.76E+00 2.61E+00 WS 51 41520 03/24/98 Ru-103 -2.39E+00 1.03E+00 3.85E+00 WS 51 41520 03/24/98 Ru-106 -6.59E+00 8.07E+00 2.99E+01 WS 51 41520 03/24/98 Sb-124 -1.32E+00 2.23E+00 8.49E+00 WS 51 41520 03/24/98 Se-75 -0.45E+00 1.06E+00 3.57E+00 WS 51 41520 03/24/98 Th-232 -1.06E+00 3.10E+00 1.10E+01 WS 51 41520 03/24/98 Zn-65 -3.09E+00 1.94E+00 7.49E+00 WS 51 41520 03/24/98 Zr-95 -0.20E+00 1.55E+00 5.69E+00 WS 51 41900 04/21/98 Ag-110M 0.27E+00 0.91E+00 3.37E+00 WS 51 41900 04/21/98 Ba-140 -0.60E+00 1.36E+00 5.66E+00 WS 51 41900 04/21/98 Be-7 -1.56E+00 7.80E+00 2.85E+01 WS 51 41900 04/21/98 Ce-141 -0.27E+00 1.72E+00 5.55E+00 WS 51 41900 04/21/98 Ce-144 -3.72E+00 5.90E+00 1.96E+01 WS 51 41900 04/21/98 Co-57 -0.32E+00 0.77E+00 2.52E+00 WS 51 41900 04/21/98 Co-58 -0.29E+00 0.96E+00 3.54E+00 WS 51 41900 04/21/98 Co-60 -1.36E+00 1.01E+00 4.40E+00 WS 51 41900 04/21/98 Cr-51 0.00E+00 1.04E+01 3.59E+01 WS 51 41900 04/21/98 Cs-134 0.26E+00 0.92E+00 3.14E+00 WS 51 41900 04/21/98 Cs-137 -0.18E+00 0.98E+00 3.78E+00 WS 51 41900 04/21/98 Fe-59 1.98E+00 2.64E+00 9.37E+00 WS 51 41900 04/21/98 I-131 -3.31E+00 2.05E+00 7.87E+00 WS 51 41900 04/21/98 K-40 2.04E+02 2.84E+01 6.56E+01
- WS 51 41900 04/21/98 Mn-54 -0.42E+00 0.89E+00 3.33E+00 WS 51 41900 04/21/98 Ru-103 2.16E+00 1.27E+00 3.97E+00 WS 51 41900 04/21/98 Ru-106 3.08E+00 1.02E+01 3.71E+01 WS 51 41900 04/21/98 Sb-124 -0.27E+00 2.25E+00 8.93E+00 WS 51 41900 04/21/98 Se-75 -2.03E+00 1.34E+00 4.93E+00 WS 51 41900 04/21/98 Th-232 2.10E+00 3.63E+00 1.27E+01 WS 51 41900 04/21/98 Zn-6L -3.16E+00 1.76E+00 8.78E+00 WS 51 41900 04/21/98 Zr-95 -1.02E+00 1.77E+00 7.04E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV. )
I l l \ Seabrook Nuclear Power Station Radiological Environmental Monitoring Program l Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
)
WS 51 42275 05/18/98 Ag-110M 1.74E+00 1.70E+00 5.56E+00 WS 51 42275 05/18/98 Ba-140 -1.43E+00 2.45E+00 9.78E+00 WS 51 42275 05/18/98 Be-7 -1.90E+01 9.78E+00 4.01E+01 WS 51 42275 05/18/98 Ce-141 0.74E+00 1.95E+00 6.10E+00 i WS 51 42275 05/18/98 Ce-144 -2.35E+00 7.52E+00 2.42E+01 l WS 51 42275 05/18/98 Co-57 0.64E+00 0.96E+00 2.97E+00 l WS 51 42275 05/18/98 Co-58 1.54E+00 1.20E+00 3.81E+00 WS 51 42275 05/18/98 Co-60 1.60E+00 1.36E+00 4.70E+00 WS 51 42275 05/18/98 Cr-51 3.13E+00 1.19E+01 4.07E+01 WS 51 42275 05/18/98 Cs-134 -0.20E+00 1.19E+00 4.21E+00 WS 51 42275 05/18/98 Cs-137 0.73E+00 1.48E+00 5.33E+00 WS 51 42275 05/18/98 Fe-59 -5.63E+00 4.04E+00 1.73E+01 ! WS 51 42275 05/18/98 I-131 1.13E+00 2.36E+00 8.04E+00 WS 51 42275 05/18/98 K-40 2.56E+02 3.53E+01 6.75E+01
- WS 51 42275 05/18/98 Mn-54 -0.26E+00 1.14E+00 4.26E+00 ;
WS 51 42275 05/18/98 Ru-103 -1.71E+00 1.14E+00 4.63E+00 ' WS 51 42275 05/18/98 Ru-106 -4.09E+00 1.19E+01 4.59E+01 l WS 51 42275 05/18/98 Sb-124 -6.92E+00 3.46E+00 1.67E+01 l WS 51 42275 05/18/98 Se-75 0.50E+00 1.69E+00 5.69E+00 l WS 51 42275 05/18/98 Th-232 1.12E+01 5.31E+00 1.53E+01 l WS 51 42275 05/18/98 Zn-65 3.05E+00 2.45E+00 8.13E+00 l WS 51 42275 05/18/98 Zr-95 -1.93E+00 1.99E+00 7.94E+00 WS 51 42825 06/22/98 Ag-110M 1.72E+00 1.17E+00 3.63E+00 WS 51 42825 06/22/98 Ba-140 0.93E+00 2.12E+00 7.43E+00 WS 51 42825 06/22/98 Be-7 1.89E+00 9.01E+00 3.10E+01 WS 51 42825 06/22/98 Ce-141 -1.35E+00 1.59E+00 5.17E+00 WS 51 42825 06/22/98 Ce-144 1.86E+00 6.20E+00 1.92E+01 WS 51 42825 06/22/98 Co-57 -1.25E+00 0.78E+00 2.57E+00 WS 51 42825 06/22/98 Co-58 -1.34E+00 1.01E+00 3.89E+00 WS 51 42825 06/22/98 Co-60 -2.41E+00 1.03E+00 4.75E+00 , WS 51 42825 06/22/98 Cr-51 3.58E+00 9.83E+00 3.29E+01 l WS 51 42825 06/22/98 Cs-134 1.25E+00 0.85E+00 2.69E+00 WS 51 42825 06/22/98 Cs-137 -0.32E+00 1.14E+00 4.26E+00 WS 51 42825 06/22/98 Fe-59 4.19E+00 2.86E+00 9.19E+00 WS 51 43130 06/22/98 H-3 5.80E+01 2.24E+02 7.80E+02 i WS 51 42825 06/22/98 I-131 -0.46E+00 2.07E+00 7.18E+00 l WS 51 42825 06/22/98 K-40 1.62E+02 2.77E+01 7.28E+01
- WS 51 42825 06/22/98 Mn-54 -0.21E+00 0.96E+00 3.45E+00 WS 51 42825 06/22/98 Ru-103 -2.81E+00 1.11E+00 4.41E+00 l WS 51 42825 06/22/98 Ru-106 -6.76E+00 9.85E+00 3.76E+01 WS 51 42825 06/22/98 Sb-124 3.15E+00 2.68E+00 8.80E+00 WS 51 42825 06/22/98 Se-75 1.24E+00 1.40E+00 4.53E+00 WS 51 42825 06/22/98 Th-232 0.35E+00 4.14E+00 1.46E+01 WS 51 42825 06/22/98 Zn-65 3.29E+00 2.35E+00 7.62E+00 WS 51 42825 06/22/98 Zr-95 -0.92E+00 1.86E+00 7.19E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
)
f5 ) Seabrook Nuclear Power Station Radiological Environmental Monitoring Program
- Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
WS 51 43217 07/20/98 Ag-110M -0.43E+00 1.01E+00 3.73E+00 l WS 51 43217 07/20/98 Ba-140 -0.99E+00 1.28E+00 5.15E+00 , WS 51 43217 07/20/98 Be-7 -0.16E+00 7.01E+00 2.46E+01 l WS 51 43217 07/20/98 Ce-141 -0.24E+00 1.48E+00 4.76E+00 WS 51 43217 07/20/98 Ce-144 3.84E+00 5.44E+00 1.68E+01 WS 51 43217 07/20/98 Co-57 0.27E+00 0.73E+00 2.26E+00 j WS 51 -43217 07/20/98- Co-58 0.32E+00 0.83E+00 2.84E+00 WS 51 43217 07/20/98 Co-60 0.95E+00 0.84E+00 2.82E+00 WS 51 43217 07/20/98 Cr-51 -4.36E+00 8.12E+00 2.85E+01 WS 51 43217 07/20/98 Cs-134 -0.32E+00 0.80E+00 2.78E+00 WS' 51 43217 07/20/98 Cs-137 -0.39E+00 0.95E+00 3.56E+00 WS 51 43217 07/20/98 Fe-59 -3.96E+00 2.41E+00 1.01E+01 i
'WS 51 43217 07/20/98 I-131 0.34E+00 1.73E+00 5.93E+00 l
WS 51 43217 07/20/98 K-40 3.28E+02 2.85E+01 5.61E+01
- WS 51 43217 07/20/98 Mn-54 1.23E+00 0.81E+00 2.49E+00 WS 51 43217 07/20/98 Ru-103 -2.70E+00 0.90E+00 3.66E+00 WS 51 43217 07/20/98 Ru-106 9.19E+00 7.61E+00 2.57E+01 WS 51 43217 07/20/98 Sb-124 0.48E+00 1.90E+00 7.00E+00 WS 51 43217 07/20/98 Se-75 0.30E+00 1.17E+00 3.90E+00 WS 51 43217 07/20/98 Th-232 2.00E+00 3.32E+00 1.13E+01 WS 51- 43217 07/20/98 Zn-65 -0.96E+00 2.09E+00 7.74E+00 WS 51 43217 07/20/98 Zr-95 2.19E+00 1.60E+00 5.33E+00 WS- 51 43550 08/17/98 Ag-110M 3.56E+00 1.97E+00 5.86E+00 WS 51 43550 08/17/98 Ba-140 -1.51E+00 2.25E+00 9.51E+00 WS 51 43550 08/17/98 Be-7 0.61E+00 1.16E+01 4.13E+01 WS 51 43550 08/17/98 Ce-141 -0.88E+00 2.01E+00 6.55E+00 WS 51 43550 08/17/98 Ce-144 8.32E+00 7.97E+00 2.42E+01 WS 51 43550 08/17/98 Co-57 -5.77E-02 0.91E+00 2.92E+00 WS 51 .43550 08/17/98 Co-58 1.65E+00 1.59E+00 5.15E+00 WS 51 43550 08/17/98 Co-60 1.92E+00 1.31E+00 4.29E+00 WS 51 43550 08/17/98 Cr-51 1.32E+01 1.20E+01 3.91E+01 WS 51 43550 08/17/98 Cs-134 1.06E+00 1.17E+00 3.54E+00 WS 51 43550 08/17/98 Cs-137 0.26E+00 1.25E+00 4.71E+00 WS 51 43550 08/17/98 Fe-59 -1.15E+00 4.95E+00 1.89E+01 WS 51 43550 08/17/98 I-131 -4.34E+00 2.61E+00 1.02E+01 WS 51 43550. 08/17/98 K-40 2.89E+02 4.21E+01 9.60E+01
- WS- 51 43550 08/17/98 Mn-54 -0.89E+00 1.11E+00 4.43E+00 WS 51 43550 08/17/98 Ru-103 -0.77E+00 1.28E+00 4.85E+00 WS 51 43550 08/17/98 Ru-106 -4.36E+00 1.07E+01 4.25E+01 WS 51 43550 08/17/98 Sb-124 -0.97E+00 3.14E+00 1.35E+01 WS 51 43550 08/17/98 Se-75 -0.22E+00 1.87E+00 6.41E+00 WS' 51 43550 08/17/98 Th-232 -0.74E+00 5.65E+00 2.07E+01 WS 51 43550 08/17/98 Zn-65 0.82E+00 2.90E+00 1.02E+01 WS 51 43550 08/17/98 Zr-95 1.60E+00 2.49E+00 8.43E+00 l
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
a
ff i l l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data l SAMPLE CONC. STD DEV. MDC TYPE STA. -LSN END DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg) l WS 51 44382 09/22/98 Ag-110M 1.09E+00 1.69E+00 5.71E+00 l WS 51 44382 09/22/98 Ba-140 0.61E+00 1.75E+00 6.73E+00 WS 51 44382 09/22/98 Be-7 3.40E+00 9.96E+00 3.46E+01 WS 51 44382 09/22/98 Ce-141 -4.77E+00 2.08E+00 7.18E+00 WS 51 44382 09/22/98 Ce-144 -7.60E+00 6.93E+00 2.29E+01 WS 51 14382 09/22/98 Co-57 -0.37E+00 0.88E+00 2.83E+00 WS 51 44382 09/22/98 Co-58 6.11E-02 1.02E+00 3.74E+00- l WS 51- 44382 09/22/98 Co-60 0.66E+00 1.40E+00 5.24E+00 ' WS 51 44382 09/22/98 Cr-51 0.00E+00 1.25E+01 4.28E+01 WS 51 44382 09/22/98 Cs-134 1.34E+00 1.00E+00 3.13E+00 WS 51 44382 09/22/98 Cs-137 0.44E+00 1.35E+00 4.90E+00 WS 51 44382 09/22/98 Fe-59 2.95E+00 4.04E+00 1.42E+01 l WS 51 45328 09/22/98 H-3 8.09E+01 2.23E+02 7.75E+02 i WS 51 44382 09/22/98 I-131 0.75E+00 2.44E+00 8.44E+00 WS 51 44382 09/22/98 K-40 2.76E+02 3.71E+01 8.01E+01
- WS 51 44382 09/22/98 Mn-54 1.44E+00 1.11E+00 3.52E+00 WS 51 44382 09/22/98 Ru-103 -1.92E+00 1.38E+00 5.29E+00 WS 51 44382 09/22/98 Ru-106 1.62E+01 1.12E+01 3.72E+01 WS 51 44382 09/22/98 Sb-124 -1.47E+00 3.04E+00 1.29E+01 WS 51 44382 09/22/98 Se-75 1.01E+00 1.61E+00 5,31E+00 WS 51 44382 09/22/98 Th-232 4.30E+00 4.55E+00 1.54E+01 WS 51 44382 09/22/98 Zn-65 6.95E+00 2.89E+00 8.20E+00 WS 51 44382 09/22/98 Zr-95 -0.63E+00 2.20E+00 8.00E+00 WS 51 45259 10/20/98 Ag-110M -1.28E+00 1.56E+00 5.80E+00 WS- 51 45259 10/20/98 Ba-140 0.96E+00 1.86E+00 6.60E+00 WS 51 45259 10/20/98 Be-7 -1.82E+01 9.72E+00 3.73E+01 WS 51 45259 10/20/98 Ce-141 -1.30E+00 1.85E+00 5.99E+00 US 51 45259 10/20/98 Ce-144 0.79E+00 6.53E+00 2.04E+01 WS 51 45259 10/20/98 Co-57 1.67E+00 0.85E+00 2.48E+00 WS 51 45259 10/20/98 Co-58 -1.75E+00 1.02E+00 4.11E+00 WS' 51 45259 10/20/98 Co-60 -0.87E+00 1.35E+00 5.44E+00 WS- 51 45259 10/20/98 Cr-51 -2.98E+00 1.00E+01 3.47E+01 WS -51 45259 10/20/98 Cs-134 -5.20E+00 2.47E+00 8.98E+00 WS 51 45259 10/20/98 Cs-137 -2.49E+00 1.28E+00 5.23E+00 WS 51 45259 10/20/98 Fe-59 4.54E+00 3.62E+00 1.19E+01 WS 51 45259 10/20/98 I-131 -0.27E+00 2.07E+00 7.16E+00 WS 51- 45259 10/20/98 K-40 3.17E+02 3.54E+01 7.36E+01
- WS 51 45259 10/20/98 Mn-54 -0.33E+00 1.04E+00 3.75E+00 WS 51 45259 10/20/98 Ru-103 -1.32E+00 1.21E+00 4.46E+00 WS 51 45259 10/20/98 Ru-106 -5.96E+00 1.10E+01 4.14E+01 WS 51 45259 10/20/98 Sb-124 0.00E+00 3.02E+00 1.16E+01 WS 51 45259 10/20/98 Se-75 3.06E+00 1.42E+00 4.35E+00 WS 51 45259 -10/20/98 Th-232 -3.37E+00 4.87E+00 1.78E+01 WS 51 45259 10/20/98 Zn-65 -0.64E+00 2.69E+00 9.98E+00 WS 51 '45259 10/20/98 Zr-95 -8.33E-02 1.98E+00 6.94E+00
- Radioactivity detected in sample (i.e., CONC > 3 STD. DEV.)
r
l l Seabrook Nuclear Power Station Radiological Environmental Monitoring Program Summary of 1998 Data SAMPLE CONC. STD DEV. MDC TYPE STA. LSN END DATE NUCLIDE 'pCi/kg) (pCi/kg) (pCi/kg) WS 51 45728 11/16/98 Ag-110M 1.38E+00 1.57E+00 5.24E+00 WS 51 45728 11/16/98 Ba-140 -4.07E+00 1.80E+00 9.00E+00 WS 51 45728 11/16/98 Be-7 0.00E+00 1.02E+01 3.65E+01 WS 51 45728 11/16/98 Ce-141 -1.70E+00 2.12E+00 6.94E+00 WS 51 45728 11/16/98 Ce-144 1.20E+01 8.31E+00 2.48E+01 WS 51 45728 11/16/98 Co-57 -C.84E+00 0.98E+00 3.20E+00 WS 51 45728 11/16/98 Co-58 1.19E+00 1.40E+00 4.63E+00 WS 51 45728 11/16/98 Co-60 -0.73E+00 1.11E+00 4.88E+00 WS 51 45728 11/16/98 Cr-51 5.23E+00 1.23E+01 4.14E+01 WS 51 45728 11/16/98 Cs-134 1.21E+00 0.99E+00 3.03E+00 WS .51 45728 11/16/98 Cs-137 0.48E+00 1.53E+00 5.55E+00 WS 51 45728 11/16/98 Fe-59 5.21E+00 3.23E+00 1.00E+01 i WS 51 '45728 11/16/98 I-131 3.63E+00 2.48E+00 7.88E+00 WS 51 45728 11/16/98 K-40 3.09E+02 4.18E+01 9.40E+01
- WS 51 45728 11/16/98 Mn-54 -1.33E+00 1.26E+00 4.92E+00 WS 51 45728 11/16/98 Ru-103 -1.80E+00 1.37E+00 5.28E+00 i WS 51 45728 11/16/98 Ru-106 2.03E+00 1.13E+01 4.20E+01 WS 51 45728 11/16/98 Sb-124 6.35E+00 3.02E+00 7.91E+00 WS 51 45728 11/16/98 Se-75 -0.46E+00 1.82E+00 6.23E+00 WS 51 45728 11/16/98 Th-232 3.13E+00 5.75E+00 1.97E+01 WS 51 45728 11/16/98 Zn-65 -0.70E+00 2.82E+00 1.09E+01 WS 51 45728 11/16/98 Zr-95 -0.13E+00 2.65E+00 9.99E+00 i WS 51 46239 12/14/98 Ag-110M -1.85E+00 1.14E+00 4.70E+00 WS 51 46239 12/14/98 Ba-140 -0.27E+00 1.82E+00 6.94E+00 WS 51 46239 12/14/98 Be-7 6.52E+00 9.40E+00 3.13E+01 WS 51 46239 12/14/98 Ce-141 -1.50E+00 1.73E+00 5.60E+00 WS 51 46239 12/14/98 Ce-144 -2.72E+00 6.12E+00 1.94E+01 WS 51 46239 12/14/98 Co-57 0.53E+00 0.82E+00 2.52E+00 WS 51 46239 12/14/98 Co-58 1.71E+00 1.04E+00 3.15E+00 WS 51 46239 12/14/98 Co-60 -1.01E+00 1.10E+00 4.50E+00 WS- 51 46239 12/14/98 Cr-51 2.17E+00 9.76E+00 3.30E+01 WS 51 46239 12/14/98 Cs-134 -1.07E+00 0.81E+00 2.93E+00 WS 51 46239 12/14/98 Cs-137 -0.81E+00 1.08E+00 4.18E+00 WS 51 46239 12/14/98 Fe-59 1.77E+00 3.26E+00 1.15E+01 WS 51 47069 12/14/98 H-3 -4.44E+02 2.28E+02 8.66E+02 WS 51 46239 12/14/98 I-131 -4.17E-02 2.49E+00 8.50E+00 WS 51 46239 12/14/98 K-40 2.38E+02 3.27E+01 8.26E+01
- WS 51 46239 12/14/98 Mn-54 0.13E+00 0.94E+00 3.30E+00 WS 51 46239 12/14/98 Ru-103 -0.39E+00 1.17E+00 4.15E+00 WS 51 46239 12/14/98 Ru-106 2.71E+00 8.78E+00 3.19E+01 WS 51 46239 12/14/98 Sb-124 0.68E+00 2.66E+00 9.80E+00 WS 51 46239 12/14/98 Se-75 -1.30E+00 1.48E+00 5.12E+00 WS 51 46239 12/14/98 Th-232 -3.86E+00 4.30E+00 1.60E+01 WS 51 46239 12/14/98 Zn-65 3.92E-02 2.54E+00 9.21E+00 WS 51 46239 12/14/98 Zr-95 1.85E+00 1.95E+00 6.76E+00
- Radioactivity detected in sample (i.e. , CONC > 3 STD. DEV. )