r Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.12
. Primary Containment Leakaae Rate Testina Proaram (continued)
BN-TOP-1 methodology may be used for Type A tests.
The corrections to NEI 94-01 which are identified on the Errata Sheet attached to the NEI letter. "A)pendix J Workshop Questions and Answers." dated Marc 1 19, 1996 are considered an integral part of NEI 94-01.
The containment isolation check valves in the Feedwater enetrations are tested per the Inservice Testing Program p(Technical Specification 5.5.6).
The peak calculated primary containment internal pressure for the design basis loss of coolant accident P., is 7.80 psig.
The maximum allowable primary containment leakage rate. L, shall be 0.20% of primary containment air weight per day at the i
calculated peak containment pressure (P,).
j Leakage rate acceptance criteria are:
a.
Primary containment leakage rate acceptance criterion is s 1.0 L However, during the first unit startup following testing., performed in accordance with this Program, the leakage rate acce and Type C tests,ptance criteria are < 0.6 L,A tests;fo-the Type B and s 0.75 L, for the Type b.
Air lock testing acceptance criteria are:
1)
Overall air lock leakage rate is s 2.5 scfh when tested at a P,.
2)
For each door, leakage rate is s 2.5 scfh when the gap between the door seals is pressurized to 2 P.,
The provisions of SR 3.0.2 do not apply to the test frequencies specified in the Primary Containment Leakage Rate Testing Program.
The provisions of SR 3.0.3 are ap)11 cable to the Primary Containment Leakage Rate Testing 3rogram.