{{#Wiki_filter:. NUREG/CR-4315 Vol. 3 Evaluation of Nuclear Facility Decommissioning Projects 1 Summary Status Report Three Mile Island Unit 2 Reactor Defueling and Disassembly Prepared by D. H. Doerge, R. L. Miller, K. S. Scotti UNC Nuclear Industries Prepared for U.S. Nuclear Regulatory Commission hDR ADOC 5 320 P PDR l

v v i i NOTICE This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government not any agency thereof, or any of their employees, makes any warranty, expressed or implied, or assumes any legal liat>thty of re-sponsibility for any third party's use, or the results of such use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such third party would not mfringe privately owned rights. NOTICE Availabihty of Reference Materials Cited in NRC Publications Most documents cited in NRC publications will be available from one of the following sources: 1. The NRC Public Document Room,1717 H Street, N.W. Washington, DC 20555

2. The Superintendent of Documents, U.S. Government Printing Oltice, Post O!! re Box 37082 Washington, DC 20013 7082
3. The National Technical Information Service, Springfield, VA 22161 Although the listing that follows represents the majority of documents cited in NRC publications, it is not intended to be exhaustive.

Referenced documents available for inspection and copying for a fee from the NRC Public Docu ment Room include NRC correspondence and internal NRC memoranda; NRC Office of InspNtion and Enforcement bulletins, circulars, information notices, inspection and investigation notices; Licensee Event Reports; vendor reports and correspondence; Commission papers; and applicant and licensee documents and correspondence. The following documents in the NUREG series are available for purchase from the GPO Sales Program: formal NRC staff and contractor reports, NRC-sponsored conference proceedings, and NRC booklets and brochures. Also available are Regulatory Guides, NRC regulations in the Code of Federal Regulations, and Nuclear Regulatory Commission issuances. Documents available from the National Technical Information Service include NUREG series reports and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission. Documents available from public and special technical libraries include all open literature items, such as books. journal and periodical articles, and transactions. Federal Register notices, federal and state legislation, and congressional reports can usually be obtained from these libraries. Documents such as theses, dissertations, foreign reports and translations, and non NRC conference proceedings are available for purchase from the organization sponsoring the publication cited. Single copies of NRC draf t reports are available free, to the extent of supply, upon written request to the Division of Technical information and Document Control, U.S. Nuclear Regulatory Com mission, Wishington, DC 20555. Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC Library, 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from the American National Standards Institute,1430 Broadway, New York, NY 10018. -.s.~

NUREG/CR-4315 Vol. 3 Evaluation of Nuclear Facility Decommissioning Projects Summary Status Report Three Mile Island Unit 2 Reactor Defueling and Disassembly Manuscript Completed: February 1986 Date Published: May 1986 Prepared by D. H. Doerge, R L. Miller, K. S. Scotti UNC Nuclear Industries Richland, WA 99352 Prepared for Division of Engineering Technology Offica of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Wcshington, D.C. 20555 NRC FIN B7568

ABSTRACT i This document summarizes information relating to the preparations for defueling the Three Mile Island Unit 2 (TMI-2) reactor and disassembly i activities being performed concurrently with decontamination of the facility. l Data have been collected from activity reports, reactcr containment entry records, and other sources and entered in a computerized data system which permits extraction / manipulation of specific data which can be used in planning for recovery from a loss of coolant event similar to that i experienced at TMI-2 on March 28, 1979. This report contains summaries of man-hours, manpower, and radiation exposures incurred during the period of April 23, 1979 to April 16, 1985, in the completion of activities related to preparation for reactor defueling. Support activities conducted outside of radiation areas are not included within the scope of this report. Computerized reports included in this document are: A chronological summary listing work performed for the period. e e Summary reports for each major task undertaken in connection with the specific scope of this report. Presented in chronological order for the referenced time period. Manually-assembled table summaries are included for: e Labor and exposures by department Labor and exposures by major activity e i iii

i TABLE OF CONTENTS PAGE

1.0 INTRODUCTION

1 2.0 ACTIVITY SUMMARIES....................... 4 4 2.1 Summary of Labor and Exposures by Department 4 2.2 Summary of Labor and Exposures by Work Activity...... 5 + 2

3.0 DESCRIPTION

OF COMPUTER REPORTS 6 3.1 TMI-2 Acronyms and Abbreviations 6 3.2 TMI-2 Notes and Descriptions 6 i 3.3 Activity Report - Reactor Defueling and Disassembly - Chronological Listing............ 6 j 3.4 Activity Report - Reactor Defueling and Disassembly - Individual Work Activities 6 .l 4.0 COMPUTER REPORTS........................ 7 e i 4.1 TMI-2 Acronyms and Abbreviations 7 4.2 TMI-2 Notes and Descriptions 13 1 4.3 Activity Report - Reactor Defueling and j Disassembly - Chronological Listing........... 16 4.4 Activity Report - Reactor Defueling and Disassembly - Individual Work Activities 43 i i. i 4 r 1 1 1 1 1 I V 1 1

EVALUATION OF NUCLEAR FACILITY DECOMMISSIONING PROJECTS PROGRAM THREE MILE ISLAND UNIT 2 Reactor Defueling and Disassembly

1.0 INTRODUCTION

The Three Mile Island Unit 2 (TMI-2) nuclear power station is located near Middletown, Pennsylvania. TMI-2 is a pressurized water reactor rated at 959 MWe. The reactor began commercial operation on December 30, 1978. On March 28, 1979, TMI-2 experienced a partial loss of coolant water which exposed the upper portion of the reactor. Resulting temperatures in the core region were in excess of 2500F causing considerable damage to the core and possibly to other reactor components. Contaminated reactor coolant water was released to the reactor building basement and to the auxiliary and fuel handling buildings (Figures 1 and 2). This release resulted in gross contamination requiring extensive 3 decontamination and waste handling operations to restore these buildings. Decontamination and repair activities have required many labor man-hours and man-rems of exposure. Because of the vast quantity of data generated during decontamination, equipment recovery and waste handling activities, the U. S. Nuclear Regulatory Commission (NRC) requested that the data be assembled, analyzed, and entered into a computer data base for historical purposes. The information also serves as a comprehensive base line for future planning, estimates, and actions required should a nuclear facility be confronted with problems similar to those experienced at TMI-2. Work within the scope of this report is being conducted under the Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program. The ENFDP program was originated in 1981 under the auspices of the NRC Office of Nuclear Regulatory Research and is currently administered through the Division of Engineering Technology. UNC Nuclear Industries (UNC) is responsible for technical direction of the program and for preparation of documentation and summary comparisons of evaluated projects. See NUREG/CR-2522, " Evaluation of Nuclear Facility Decommissioning Projects," for a complete description of the Program Plan. Under the ENFDP program, data is assembled in a form that permits input into a computerized decommissioning data system (DDS). A proprietary computer software package, MAPPER, provides a method for accumulation and manipulation of decommissioning performance information. MAPPER stands for Maintain, Prepare, and Produce Executive Reports. _1_

THREE MILE ISLAND UNIT 2 REACTCR BU3 Di';G (CG !TAlf'MEfJT) AUX]UARY BUILD ?JG C00UNG TOWER ig s,.a i g n....,.. g s,...,,,,.. g.. - G G v..w.i.a., f' .c. ;

  • 9 i...i Tli;ialTJ2 BUILDit'G

~..,. - c... G l. / g,,,,,, n...., .eu t t.c.. i....- v...... G..==@a=~el p c m. i.I @.,...., i q oj ' h, .i.. _ r'"M . t,,, e. .rm.- f' e ,,,, li i q s'.. -- K l{te.s'v.* C' v..i... - S H{ I l _,' ' p,_ ~~ 9;,;:,1, ) ^Cw p.. 9. . -== -- ; __ ~ =

===

<1.---

m. y y 3:.

I ,,,...,,,Q. n..,_. m......... --- l~_,7; - l .....ip @ ::.

7. g

..m._ :, c.,,, 1.,, r-F 2 i. -,. a-l y I e,.... n, = q w%- -.p x_ s m,,...l\\ \\ Y,.. i e _..._ c... y ;u m_. u _ m y m s-, -t s-e m ..= g _ .;t s............... ....,............x...., c., s..... Figure 1. Reactor & Auxillary Buildings. \\ _. _ - _ _ _ _ _ _S l ^ i ......._.---) d .. EW = l s _..e ... =.. a..u.w-.. ,.y. [ \\ i 4.. ,,4 ~. o. u _. ~-, .n.. - m s_a i o w . 3.. ~ .= ~ .u a = ~- o /K%e 2 D =.2 .h,, o a g 7.h.. m p a ~'~ 5 x/ C] I i -- L _,J /\\ 11 M'o o n grg( _ p;7 g = = .u. o... _o_] l o . o. o v= ( i - ~.~ _ --.e .,f c ou..s s ,g .m ~= v .m .. u... w c, Figure 2. Auxiliary & Fuel-Handling Building.

6 NUR EG /CR-4315 Because of the volume and variety of information being collected Vf'I $l-2, T nine categories of ENFDP reports have been established and are as follows: Volume 1 - Reactor Coolant System and S_ystems Decontamination Volum Evalyogn:e 2 - Reactw I ildin6 epDisasseqm lyOecontamiFion lity umegn o-U r ci i - Reactor D ue ing - m3 u a c el Ha s.t s Decontamination Volume 5 - Common Support Facilities and Systems Operations Volume 6 - Plant Stability and Safety Activities Summary OfEtiS Repfp aste Hanmng Three Mihydy{ggchuny'ofid Waste landling Reactor Datuehng and Disassem aly Vnluma 0 - Radioac+' a Wasto and Immdru N m'onte Manuscript Completed: February 1986 Date Published: May 1986 Prepared by D. H. Doerge, R L. Miller, K. S. Scotti UNC Nuclear Industries fuchland, WA 99352 Prepared for Divi ion of Engineering Technology Offica of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Wcshington, D.C. 20555 NRC FIN 87568

i 2.0 ACTIVITY SUMMARIES 2.1 Summary of Labor and Exposures by Department REACTOR DEFUELING AND DISASSEMBLY (April 23, 1979 to April 16,.1985) Personnel Labor Exposure l-Entries. Man-Hours Man-Rem j AD - Unit 2 Administration 2 3.05 0.146 AM - Administration - Unit 1 2 2.46 0.656 CM - Unit 2 Maintenance (Gen) 42 75.09 4.156 CN - Contractor (all crafts) 3,052 6,580.53 313.591 12 21.47 0.503 l CR - Corporate 1 2.93 0.300 EC - Electrical Maintenance-Unit 1 EG - Engineering Staff - Unit 1 2 12.39 .0.004 4 EL - Unit 2 Electrical Maintenance 235 535.86 24.654 ES - Unit 2 Engineerina Staff 3? 74.09 4 EAR c 1 i I i t I I I 1 3

2.2 Summary of Labor and Exposures by Work Activity A6K{M{'T_ ' [a",P3"',' d*n$'o,, o %#C:"I'Eu?"M" "' 5?? 1:in In:"* This documer{gtspf,ggpcgt,information rg atin defueling the htweee ehde f"s' land Unit 2idTMI ggj the preg @tions for 2h2meactor ar4aodisassembly activities t@g"g@fM&d"concurrentigwith }i@ontamina()M of the i i facility. Rt Head Insulation 66 8.438 121.73 [ 2 C na e e Data have bsM troMbcted from activityj9eport4 records, anddh'Ett,"d[dgTmt and entered hn a 6,4d)49 reactor gpttainment entryguterize d permits extqgtggig,gion of spegfic gg which cg8pe used in 3 planning fontcrenvervyi bordi a loss of coolant nwont similar.6&o that experienced Cg; g E on March 28,1979y j;3l* yl3 Temporary Power 19 0.204 27.28 This report @gpgignmaries of man-h urs, in@ power, ar3@adiation exposures iretwowd darriingarthe period of)i Apri ts.fG,1979 tu0 April 16,1985 in the compljf @ Q f'Bttivities relatedjto p 4?$jration fd @ eactor defueling. not includecl?1gE6"ITe scope of this report.n.nuSupp$tt ebtivities condactep outqig g n areas are in i Computerized reports included in this document are: A chronological summary listing work performed for the period. e o Summary reports for each major task undertaken in connection with the specific scope of this report. Presented in chronological order for the referenced time period. Manually-assembled table summaries are included for: e Labor and exposures by department Labor and exposures by major activity e iii

3.0 DESCRIPTION

OF COMPUTER REPORTS The computer reports included in this document are: 3.1 TMI-2 Acronyms and Abbreviations This report is a general report listing' acronyms and abbreviations used in TMI-2 reports. All acronyms and abbreviations listed in this report are not necessarily used in this document but may be used in-other volumes of NUREG/CR-4315. 3.2 THI-2 Notes and Descriptions This report describes the data by column found in the computer-generated activity reports. It also includes a listing of department code abbreviations. 3.3-Activity Report - Reactor Defueling and Disassembly (chronolonien1 listino) d 5 A F 5-

\\ / 4.0 COMPUTER REPORTS IABLL u-CONTEN!S 4.1 THI-2 Acronyms and Abbreviations PnjE i.e

N1RDDUETION d.0 ACilVITY SUMMARIES.

J 7.1 Summary of Labor avui Exposures by Department 4 2.2 Summary of Labor and Exposures by Work Activity. 4 3.0 LESCRIPTION OF COMPUTER REPORTS 6 3.1 TMI-2 Acronyms and Abbreviations / 3.2 TMI-2 Hotes and Descriptions E 3.3 Activity Report - Reactor Defueling and Disassembly - Chronological Listing.. 6 3.4 Activity Report - Reactor Defueling and Disassembly - Individual Work Activities 6 4.0 COMPUTER REPDRTS.. 7 4.1 TMI-2 Acronyms and Abbreviations 7 4.2 IMI-2 Notes and Descriptions .. 13 4.3 Activity Report - Reactor Detueling and Disassembly - Chronological Listing...... 16 4.4 Activity Report - Reactor Defueling and Disassembly - Individual Work Activities . 43 i i l '7-

m. _.m._ _. _ ~ _. _ _ _ _ _ _ _ _. -.... _. -.._-.... _.. -~_ i E DATE 062585 PAGE 2 PNO. I .TMI-2 UNC: DOS - ACRONYMS AND ABBREVIATIONS FOR TMI-2 REPORTS M H3036 .T.FLD,

  • AC. R. O.N. YM.... M. O.D. P. NU.M...................D. E. S.C. R I P T I O. N
  • THIS REPORT IS A WORKING DOCUMENT AND WILL BE UPDATED PERIODICALLY.
  • (SOME ABBREVIATIONS FOUND IN DATA HAVE NOT BEEN IDENTIFIED TO DATE. THESE
  • ABBREVIATIONS OR ACRONYMS WILL BE IDENTIFIED AND INCLUDED IN SUBSEQUENT

,* REPORTS) ACC ACCESS h AC00S ACOUSTIC OR ACOUSTICAL ACQ ACQUISITION ACQUI ACQUISITION ADPTR ADAPTER AFHB . AUXILIARY AND FUEL HANDLING BUILDING AH AIR HANDLING AHE AIR HANDLING EQUIPMENT AHVG AIR HANDLING VALVE 'G' AH-C AIR HANDLING VALVE 'C' .ALC AUXILIARY LIQUID CLEANUP (EPICOR 2) ANN -ANNULUS APSR AXIAL POWER SHAPING ROD ARLK AIRLOCK s AUX , AUXILIARY (BUILDING) BLK BLOCK ' yo BTL(S) f.. . BABCOCK & WILCOX BWST ' BOTTLE (S) BORATED WATER STORAGE TANK B&W CAT 10 CHEMICAL ADDITION TANK i CCB CHEMICAL CLEANING BUILDING CCTB

p CHEMICAL CLEANING TANK *B' CCTV CLOSED CIRCUIT TELEVISION t

CDT CONDENSATE DRAIN TANK CFT CORE FLOOD TANK t CHEM ACD3 CHEMICAL ADDITION CHK CHECK CLR(S). COOLER (S) CNTRL CONTROL COL . COLUMN CONC CONCENTRATED COND CONDENSER OR CONDENSATE CONN CONNECT OR CONNECTOR CONST CONSTRUCT OR CONSTRUCTION- 'l CONT CONTAMINATED CONTR CONTRACTOR CORR CORRIDOR COUP COUPLE OR COUPLING 1 COV COVERAGE CRD CONTHOL ROD DRIVE CRDM CONTROL ROD DRIVE MECHANISM CTMT CONTAINMENT CU . CLEAN UP. 1 t r t- ~ -*m -a

1 i l l EVALUA110N OF NUCLEAR FACILITY DECOMf11SSIONING PROJECTS PROGRAM n THREE MILE ISLAND UNIT 2 j Reactor Defueling and Disassembly ,o 2 1.0 I._NTfi:]DUC T I ON_ 5eThree3MileIslandUnit2(TMI-2)nuclearpowerstatiunislocatednear Ifiddletowje, Pennsylvania. TMI-2 is a pressurized water reactor rated at 9tS9 MWe. :The reactor began commercial operation on December 30, 1978. a On March 2"8, 1979 TMI-2 experienced a partial loss of coolant water which exposedtheupper,portionofthereactor. Resulting temperatures in the core regitn were in excess of 2500F causing considerable damage to the core andpossiblytootherreactorcomponents. Contamina ed reactor coolant water was released to the reactor building casement and to the auxiliary and fuel handling buildings (Figures 1 and Thisirelease resulted in gross contamination requiring extensive 2). decon#bmitiation and waste handling operations to restore these buildings. Decon$mihationandrepairactivitieshaverequiredmanylaborman-hours andm&n-r{msofexposure. Becau equip @g of the vast quantity of data generated during decontamination, nt: recovery and waste handling activities, the U. S. Nuclear Regulgorj Commission (NRC) requested that the @ta begssembled, analyzed, and erliered into a computer data base for histotiical p# poses. The inforrhtijn also serves as a comprehensive base @ine f0' future planning, o estimges; and actions required should a nuclear 5facElirty be confronted with p}obhps similar 40 those experienced at ETib2.5 5 E

5 0
  • ag g2 g

Work itlig the scope"pf this report is being5-8tsuc0edlcndeE the Evalugiti g The EigCg:gf Nuclear Eagi,lity Degommissigninty f@[je{t@ENF[g,) program. mram wigs prnginated gn 1981 gndec 122Waqs(@Ces560 the NRCgm r Officdlto*jg$ ear RsAt aggry ReseSrch f $ is M yyt[y the D1g1f;ppgg E ;gtnegrggg Techng!cg%3ag . S S0 255 M t

22oSm a ' # ud

==E Ws000 % "a EE O 4 o m .oam-m s z mmm m--aos mz -o-m 2 UNC Nu5 eegdmp< ($$CE u. respormate feantacical dicacuois of the l prograt arj g g g g b94 evalue ed:;{33gsgLEg $g}p592b8umerMj;i;o,g @fsgMd";@$YE$t$s of J Decomm@isspggggE8g8Jgy8,QQQ3QQ@@QQf@jsM@6@@s{si@63$3 =tf66EMEE*M,-'" t g emrt35 M do E !LC,8M 50t c"! ! i ty g .uaooooooooommmmmmmmmmmmmmmmmoczzzzzzzzz-~~-----ass UndertBhNFDPprogram,datais embled in a f orm that permits input into a ;W6puterized decommission data system (DDS). A proprietary computB ftware package, MAPPE rovides a method for accumulation and manipul @tyon of decommissioning ~ e ormance information. MAPPER stands for Maintain Prepare,andPJt@te(x ive Reports. y o 53 5d EEm L - x S E2 a5 u mzz .. '. 5:3 88E >M 10m S$B' sham 02->omWzT f" -i!.5bomu >SG;0m 25 4:33EEEEEEt83tddddS$555~"""tt2089YEiiiEliM:""""""59" m -M M M ~

._m T [] +. DATE 2062585. PA LE. 9h ~

3 p' r'

- : 1 ' i - L ~- 4 s s l e - - g a1 PNO. ..3_. .TMI-? b,. .- UNC; DDS.. ACRONYMS _AND. ABBREVIATIONS #0R TMI-2 REPORTS M H3036 .N'- 'i*

r

---T j F L D. t t i i , t DESCRIPTION i

  • ..CRONIH..,MODTP.NUM.
  • A

..................4................t..................................... ..n...

  • s

+ MJ 3 LN(S) Lt ---~ LINE ( S T ; D ' i : ! is N i' P M LOSS OF COOLANT ACQIDENT N. / L! ( E 'n k- - : L OW P R E SSU8 E.'pr * ' - ' NY - j( ""M-- C OCA {s i - f w ,._ _ / ['.' "T1 T Mp,gNE T IC i 1. M >l O Il3AINTlji11

    • enG

) 4 1,, b' e1. MAINTAIN OR MA!NTENANQEl [ 3 E O 4 l' I I j 2 K ',L - r!E- @TL ((3g yE, & L. - U C s r ' ,e < l . H  ; jt - h -dI C . : F i MOT 04 CONTWOL~I' 7 1 1j'+' L d O ICONTROL, CENTER j,r 4 i ! h:'* iip, i t y C CTR,j } In D! { C MOTO l! 1, ' O 3 MINI DECAY I -' i Il 2 - MINI DECAV(HEATIHE AT REMOVAf SYSTEM ! ;, +'.';:;.0 DH t jj !'f,'] 1 d HRi g+ ; ,s NIT (S) ll

MONIT R{S)Ii k'

I li g. Mth g q iq.i M.. b-~-. ME ASURE OR TME ASUREptENT ! y ' MEAS' as i MISCl th 1g.' A t t i MISCELLANE0yS .,4(< L, $ ;. ~, ; + ; ' ;n. 2 f :! () P 3 ;*/ } ,4 e 4' D VA6E L}l (! ';d - t O ], j... MO T M O P R A T E.h,,] i :t,;; ;,; j ! p,3 p t }. ,5.. OV l ,, J EMPTY. T -"u va 2 -,, 7 i g22n;p n1 MAK [ tJP [' _ _, U-j t 4..... i i>d i ';;!!U 8l O P f-h 3

      • U F l

d< I U;- M 4/ D l MAK i UP F1ILTER :t I b ( id PUMP i ! r -MAI'O 'l UPMAMi (JP VALVE U rm - d @i '+

11 3DP D

e '

  • g 'I

{ Q 4 S ) Ifl ",:4 9 E U p ?; b V li i i: MISCE LLANEOUS WAS1E

  • l t!

I l m f~ ~ ] MISCELLANEOUS WASTE HOLDUP TANK!l!4 'd Z ti l' S f IU rNUCLEAR I.kSTRUM(NT,CRJINS'TRUMENTAT10M d ',/- [jd ; HT {' 1 l -: t rb NEUT h } }i W ! MISCELLANEOU3 WASTE *. TANK { s j l+ i ' p l r i e T I i r- ',.J , *" ?f q NEUTRON 4{8& i* i HI 1 =i _3 i E. U) .h ?. LB j[. L I . ' s' i MANA CTURER15.NAMEur0R2 HYDR O LASE R.;PuttR. J, :. p 'f I! NITRO EN fANIFOLD i q ' l :e l g;,JJ T g r RlREC ULATORY CDMMI$y" d;"b sf 1 D I-{. J ~-('y p' f N07ZE O.1SilNUdLLf2;!I

r 4

ZZ 3 m M - y 1 l lt N++ U R@ 7 C L:==* : A ="

', 4 n

~ G 1 i 4.3 ^ ^MUCLEAR SESVICE,

  1. 1

'M C i ?(f Fj "j, t ~ rM

4. EAR l U r r-l IN H 1 1i A M:!d 1
  • m)C

$UC [NSTk j r, _'N EAR IN$.TRUMENTATIONi K ?* QU ID ?=l-M I' lM u l =g ^' C 2 '; 4 f' t'NITRQGENl

  • ' 'i j

I' 4 OPERATIONS d, J7 l g 3 4 '; ' ER 'D ', ?-

i 'O PE R A T IOP4.-

-- Q - - - - - H R 2 > '.i t ! - S r i U,,T h ' TSG IH '. ONCE-THROUGH JiiTEAM 4ENERATOR j'V j' --(

  • PA KAGE LJ CK t

A C-OR P.C. ! PO AR CRANE t ' _. J L. PENETRATION O 'h ~ ,~d ~ N RS! ^ ^- 7iW4 '-" "PE R SOM f Si-DR 9 PE RS'ONNE L i jk i,1 "1"" 1 w;' i NEE' i e A ) "l? tT{~ ~; PHOTOGRAPH OR PHOTOGR APHIC -pI'

I

^il HOTO' !' 1i-,ll L PRE VENT ATIVE 1 MAINTENANCE i i1 d [' KG l "it} . PACKAGEn N' 'w l 1 hM OR $P'j4n[P 4/ \\ l yt C . _ #,/- I !,cd'b PUMP l RE/ OPER ATED RELIEF [ VALVE [J [ lI ' P y-J PRESSU -I. f, ORV g [ J2 i-- -+l l PR(PARATION 7?(y EP e r*J B PROTECTION I' t i L .0T ST PROCESS WATER STORAGE TANK .l ? j

  • MR PRESSURIZER il,

l 0 O "NAD ' RADIATION, RADICACTKVE,1 RADIOLOGICAL t.l2 f, _. ' l, m...'- (} pt.p}'. 25 d. s L a s w,,,. ,s -a .4 Q . _ - - - -. ~ ,me' N l. q wJ IQ l

DATE 062585 PAGE 5 PNO. 4 .TMI-2 UNC: DDS - ACPONYMS AND ABBREVIATIONS FOR TMI-2 REPORTS M H3036 .T.FLD.

  • ACRONYM s...........M00.P.NUM........................ ESC.RIPT. ION D

RAP RB REAC?OR BUILDING RBA RECLAIMED BORIC ACID PUMP ROOM RBAT RECLAIMED BORIC ACID TANK RC REACTOR COOLANT RCBT REACTOR COOLANT BLEED TANK RCDT REACTOR COOLANT DRAIN TANK RCF RCS REACTOR COOLANT SYSTEM RECIRC RECIRCULATE OR RECIRCULATION RECOMB RECOMBINER RELOC RELOCATE RES RESIN RET RETURN RMVE REMOVE RM(S) ROOM (S) RO-2A RADIATION DETECTION INSTRUMENT RV REACTOR VESSEL RVHSS REACTOR VESSEL HEAD SERVICE STRUCTURE RWP RADIATION WORK PERMIT SAM COMMUNICATIONS SYSTEM SAMP SAMPLE SCAF SCAFFOLD SDS SUBMERGED DEMINERALIZER SYSTEM g _a SECT SECTION -a SERV SERVICE e SF SPENT FUEL SFC SPENT FUEL COOLER SFF SPENT FUEL FILTER SFP SPENT FUEL POOL SFV SHLD(G) SHIELD OR SHIELDIdG SPC STANDBY PRESSURE CONTROL SPEC SPECIAL OR SPECIFICATION SPEC (T) SPECTRA. SPECTRUM, OR SPECTROMETER SSTR STAB STABILIZE OR STABILITY SUPP SUPPORT SURV SURVEY SWS-P PUMP IN SPENT FUEL POOL (REMOVED) SYS SYSTEM TEMP ~ TEMPORARY -TER ~ TE*MINATE* 0R TERMIMAL-., THRU THROUGH TK(Sj TANKfS) TLD THERM 0 LUMINESCENT DOSIMETER TRO ' TURB TURBINE'(BUILDING) TV TELEVISION UCI .MICRDCURIE

DATE 062585 PAGE 6 PNO. 5 .TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR THI-2 REPORTS M H3036 .T.FLD.

  • ACRO.NY.M.... MOD. P. NUM.......................... TION DESCRIP V

VALVE (USED IN CONJUNCTION WITH A NUMBER OR LETTER) VAC VACUUM VLV VALVE WDG WASTE DISPOSAL-GASE0US WDL WASTE DISPOSAL-LIQUID WDS WASTE DISPOSAL-SOLID XFR TRANSFER XPORT TRANSPORT END REPORT ea N I

4.0 COMPUTER REPORTS 4.2 TMI-2 Notes and Descriptions i i.-

n. DATE 062585 PAGE 2 PNO. 1 .TMI-2 UNC: DDS - ACTIVITY REPORT - THI-2 NOTES AND DESCRIPTIONS M 286 D

  • RWP

.RWP .EXP TRCK. .PERS . DEPT.EEPOS RWP.............. T. A. S. K..D. E. S.C. R..I P. T I O. N.

  • .D. A. T. E.. N. U.MBE.R.. N. UMB. E. R..,...... AC. T. IV. I T. Y.............. E. N T R. NG.. C. O.D.E..,..R.E.M...H.O.U.R S.
  • DATA IN THIS REPORT ARE CDMPLETE T..nT00GH MARCH 31. 1985. SUBSEQUENT DATA
  • WILL EE ANALYZED AND ADDED PERIODICALLY.
  • NOTES:
  • I.

DESCRIPTION OF DATA IN EACH COLUMN; RWP DATE - THE DATE OF ISSUE OF THE RADIATION WORK PERMIT. THE PERMIT MAY COVER A SINGLE ENTRY OR MAY COVER ENTRIES OVER A PERIOD OF TIME OF UP TO ONE bEEKS DURATION. RWP NUM8ER - RADIATION WORK PERMIT IDENTIFICATION NUMBER. EXP TRCK NUMBER-EXPOSURE TRACKING NUMEER - AN IDENTIFICATION NUMBER da ASSIGNED TO A SPECIFIC ACTIVITY. i ' ACTIVITY - DESCRIPTION OF AN ACTIVITY OR THE LOCATION OF A ? TASK WITHIN AN ACTIVITY. PERS ENTRG = NUMBER OF PERSONNEL ENTERING A RADIATION AREA OR PERFORMING WORK WHICH IS COVERED BY AN RWP. DEPT CDCE - A PERSONNEL ACCOUNT!*3 CODE FOR FUNCTIONAL DEPARTMENT IDENTIFIwATION. (SEE NOTE 2) EXPOS REM - ACTUAL RADIATION EXPOSURE IN REM, RERCORDED ON TLDS WORN BY EMPLOYEES DURING fERFORMANCE OF A TASK WHICH IS COVERED BY AN RWP. AN EMPLOYEE MAY WORK ON AN RWP COVERED TASK FOR SEVERAL HOURS AND RECEIVE NO MEASUR-A8LE RADIATION EXPOSURE. TIME SPENT ON A TASK INCLUDING J08 PREPARATIONRECORD WAS INITIATED IN NOVEMBEd, DRESS-RWP HOURS - 1979. , UNDRESS ETC. TASK DESCRIPTION - SELF EXPLANATORY

  • 2.

DEPARTMENT CODE ASSREVIATIONS: AD - UNIT-2 ADMINISTRATION AM - ADMINISTRATION - UNIT I BS - UNIT-2 BUILDING SERVICES CH - CHEMISTRY-UNIT I CM - UNIT-2 PLANT OPERATIONS MAINTENANCE - GENERAL CN - CONTRACTOR (ALL CRAFTS) CR - CORPORATE DM - UNIT-2 DECOM MAINTENANCE (REPLACED BY RECOVERY PROGRAM-RP) EC - ELECTRICAL MAINTENANCE - UNIT I EG - ENGINEERING STAFF-UNIT I I

DATE 062585 PAGE 3 PNO. 2 .TMI-2 UNC: DDS - ACTIVITY REPORT - TMI-2 NOTES AND DESCRIPTIONS H 286 D

  • RWP

.RWP .EXP TRCK. .PERS . DEPT. EXPOS RWP.

  • D. A. TE.. NU.MB.E.R.. N.U.MB.E.R...........C. T. I V. I T. Y................ E.N. T. R N.G.. C. O.D E......R.E.M.....

A EL - UNIT-2 PLANT OPERATIONS ELECTRICAL MAINTENANCE ES - UNIT-2 ENGINEERING STAFF HP - UNIT-2 HEALTH PHYSICS (RADIOLOGICAL ENGINEERING) IC - UNIT-2 PLANT OPERATIONS INSTRUMENT AND CONTROL MD e UNIT-2 MAINTENANCE ADMINISTRATION ME - MECHANICAL MAINTENANCE-UNIT I MM - UNIT-2 PLANT OPERATIONS MECHANICAL MAINTENANCE OP - UNIT-2 SITE OPERATIONS OS - OPERATIONS-UNIT I QA - UNIT-2 OUALITY ASSURANCE RC - RADIATION CONTROL-UNIT I RP - UNIT-2 RECOVERY PROGRAM . RW - RAD WASTE - UNIT 1 .SE - UNIT 2 SECURITY UM - UNIT-2 UTILITIES MAINTENANCE f UT - UTILITIES MAINTENANCE - UNIT I c: _J VI - VISITOR on END REPORT s L P e-, W 4 oy f

i 4 '4.0 COMPUTER REPORTS 4.3 -Activity Report - Reactor Defueling and Disassembly (chronological listing) i i 4 i j i t 4 4 1 1 1 4 i I I i i l 1 I i i J J } 1 i - 1 i 4 --wm- ..n--w.n.--.w,-rm,vwr~ev.,, n, r . - ~ v-..ne-,---.- en... ,-~,-,--.,--n-v nc,,--n-a-,-,-n. -, - v-w, r,~ e ---, e--

. - ~ _ DATE 022186 PAGE 2 PNO. 1 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. CEPT EXPOS. RWP. .............. T. A S. K.D. E. S. C. R I P T I O. N...........

  • D. A T E... N UMBE. R... U.MB E. R.............IV.ITY...............

E.NTRG.CO.DE.....E.M......U.RS.......... N ACT R HO 790423 022682 D20A001 RX DISASSEMSLY PREP 4 CN 0.125 DNA CLE AN UP ARE A FOR CR ANE USE 810427 000967 D41C011 VENT & SAMPLE RX GAS 3 CN 0.013 5.58 SAMPLE REACTOR BUILDING ATMOSPHERE I

  • 810427 000967 041C011 VENT & SAMPLE RX GAS 1 HP 0.000 2.50 SAMPLE REACTOR BUILDING ATMOSPHERE 810511 001046 D41C011 VENT & SAMPLE RX GAS 2 HP 0.002 7.00 SAMPLE REACTOR BUILDING AiA0 SPHERE 810523 001117 D41C011 VENT & SAMPLE RX GAS 5 CN 0.008 20.67 SAMPLE REACTOR BUILDING ATMOSPHERE 810613 001265 041C011 VENT & SAMPLE RX GAS 1 CN 0.005 4.83 SAMPLE REACTOR BUILDING ATMOSPHERE 810613 001265 D41C011 VENT & SAMPLE RX GAS 1 UM 0.000 4.33 SAMPLE REACTOR BUILDING ATMOSPHERE 810613 001265 041C011 VENT & SAMPLE RX GAS 1 HP 0.000 3.00 SAMPLE REACTOR BUILDING ATMOSPHERE 820513 003843 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.154 1.73 MEASURE MISSILE SHIELD GAPS / PHOTOGRAPH
  • 820513 003843 041C001 IN-CTMT RAD SURVEYS 1 ES 0.200 1.82 MEASURE MISSILE SHIELD GAPS / PHOTOGRAPH 820513 003844 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.239 1.83 RADIATION SURVEYS OF RVHSS
  • 820513 003844 041C001 IN-CTMT RAD SURVEYS 1 ES 0.161 1.83 RADIATION SURVEYS OF RVHSS 820526 003949 041C001 IN-CTMT RAD SURVEYS 1 CN 0.334 2 50 REMOTE SURVEY OF

'B' D RING

  • 820526 003949 D41C001 IN-CTMT RAD SURVEYS 1 OP 0.300 2.42 REMOTE SURVEY OF

'B' D RING 820526 003952 D41C001 IN-CTMT RAD SURVEYS 2 OP 0.811 3.33 SURVEY AND INSPECT 'A' D RING VALVES

  • 820526 003952 D41C001 IN-CTMT RAD SURVEYS 2 CN 0.933 3.75 SURVEY-AND INSPECT

'A' D RING VALVES 820603 003999 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.182 0.88 RADIATION SURVEY 820603 003993 D41C003 CRDM TOOL INVENTORY 2 CN 0.165 2.67 INVENTORY CRDM TOOLS 820610 034^42 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.167 1.50 RADIATION SURVEY 820610 004041 D41C004 N-2 SYS ACTIVITY 1 OP 0.227 2,42 NITROGEN SYSTEM OPERATION TEST

  • 820610 004041 D41C'04 N-2 SYS ACTIVITY 1 HP 0.235 2.50 NITROGEN SYSTEM OPERATION TEST 820610 004044 D41C004 N-2 SYS ACTIVITY 1 OP 0.014 2.00 INSPECT NITROGEN SYSTEM e
  • 820610 004044 D41C004. N-2 SYS ACTIVITY 1 CN 0.025 2.17 INSPECT NITROGEN SYSTEM d

820610 004039 D41C005 ELECTRICAL SUPPORT 3 CN 0.298 4.25 INSTALL EMERGENCY LIGHTING FOR RVHSS '4 820630 004192 D41C001 IN-CTMT RAD SURVEYS 3 CN 0.613 5.83 DECON 'B' D RING / REMOTE SURVEY OF D RING 8

  • 820630 004192 D41C001 IN-CTMT RAD SURVEYS 1 ES 0.095 1,62 DECON

'B' D RING / REMOTE SURVEY OF D RING

  • 820630 004192 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.120 1.30 DECON

'B' D RING / REMOTE SURVEY OF 0 RING 820630 004190 D41C015 HOIST /RIGNG/ PLATFORM 2 CN 0.251 1.83 INSTALL CRDM WORK PLATFORM 820630 004191 041C015 HOIST /RIGNG/ PLATFORM 4 CN 0.502 7.52 INSTALL TROL 1EY& HOIST FOR LDSCR REMOVAL 820702 004200 D41C001 IN-CTMT RAD SURVEYS 3 CN 0.048 8.00 ERECT /RMVE SCAFF/INSTL TUBING,1NSTS/ TEST

  • 820702 004200 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.005 2.67 ERECT /RMVE SCAFF/INSTL TUBING,INSTS/ TEST l

820707 004229 D41C001 IN-CTMT RAD SURVEYS 1 ES 0.180 1.83 REMOTE SURVEY OF 'B' D RING $820707 004229 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.160 1.83 REMOTE SURVEY OF 'B' D RING 820707 004225 D41C004 N-2 SYS ACTIVITY 4 HP 0.080 6.08 INSTALL INSTRUMENT TUBING $820707 004225 D41C004 N-2 SYS ACTIVITY 6 CN 0.179 16.25 INSTALL INSTRUMENT TUBING

  • S20707 004225 041C004 N-2 SYS ACTIVITY 2 QA 0.046 5.25 INSTALL INSTRUMENT TUBING
  • 820707 004225 041C004 N-2 SYS ACTIVITY 1 OP 0.010 0.75 INSTALL INSTRUMENT TUBING 820707 004230 D41C004 N-2 SYS ACTIVITY 5 CN 0.775 9.17 NITROGEN SYSTEM HOOKUP 820709 004241 041C004 N-2 SYS ACTIVITY 4 CN 0.005 6,04 INSTALL & TEST NITROGEN TUBING-305'ELEV
  • 820709 004241 D41C004 N-2 SYS ACTIVITY 1 QA 0.003 1.33 INSTALL & TEST NITROGEN TUBING-305'ELEV 820709 004243 041C004 N-2 SYS ACTIVITY 1 CR 0.015 4.17 INSTALL & TEST INST TUBING & INSTRUMENTS
  • 820709 004243 D41C004 N-2 SYS ACTIVITY 7 HP 0.055 11.00 INSTALL & TEST INST TUBING & INSTRUMENTS
  • 820709 004243 D41C004 N-2 SYS ACTIVITY 11 CN 0.169 27.66 INSTALL & TEST INST TUBING & INSTRUMENTS
  • 820709 004243 D41C004 N-2 SYS ACTIVITY 2 QA 0.030 7.25 INSTALL & TEST INST TUBING & INSTRUMENTS
  • 820709 004243 D41C004 N-2 SYS ACTIVITY 1 OP 0.010 1 42 INSTALL & TEST INST TUBING & INSTRUMENTS 820710 004250 041C001 IN-CTMT RAD SURVEYS 2 CN 0.008 3.67 INSTALL PRESSURE TAP 820712 004283 D41C001 IN-CTMT RAD SURVEYS 3 IC 0.005 6.00 MARK CABLE FOR QUICK LOOK CAMERA 4
  • 820712 004283 041C001 IN-CTMT RAD SURVEYS 1 CN 0.000 2.00 MARK CABLE FOR QUICK LOOK CAMERA 820713 004285 D41C004 N-2 SYS ACTIVITY 2 HP 0.000 14.00 HOT TAP MS BLANK FLANGES
  • 820713 004285 D41C004 N-2 SYS ACTIVITY 9 CN 0.000 62.42 HOT TAP MS BLANK FLANGES

DATE 022186 PAGE 3 PNO 2 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. TASK DESCRIPTION

  • DAT E... NU.MB E.R

.......E.R.............IVITY..........................CODE.................................................................., NUMB ACT ENTRG. REM HOURS 4 820714 004299 D41C004 N-2 SYS ACTIVITY 3 CN 0.005 3.17 REMOVE SCAFFOLD FROM WESTINGHOUSE VALVE 820714 004300 D41C004 N-2 SYS ACTIVITY 2 CN 0.010 1.95 REMOVE SCAFFOLD FROM ANNULUS HALLWAY 820714 004278 D41C005 ELECTRICAL SUPPORT 3 CN 0.322 3.38 INSTALL EMERGENCY LIGHTING 820714 004279 D41C008 VENT & FILL S/G 7 OP 1.684 10.43 VENT RCS/ PROVIDE N-2 BLANKET / VENT OTSG A . *820714 004279 D41C008 VENT & FILL S/G 4 HP 0.729 6.75 VENT RCS/ PROVIDE N-2 BLANKET / VENT OTSG A

  • 820714 004279 D41C008 VENT & FILL S/G 1 CN 0.082 0.87 VENT RCS/ PROVIDE N-2 BLANKET / VENT OTSG A 4

820715 004287 D41C008 VENT & FILL S/G 1 OP 0.087 0.83 VENT RCS/ VENT OTSG A - *820715 004287 041C003 VENT & FILL S/G 1 HP 0.025 0.17 . VENT RCS/ VENT OTSG A 820715 004290 D41C013 RAD. INSTRUMENTATION 1 CN 0 120 1.50 INSTALL RADIATION DETECTORS

  • 820715 004290 D41C013 RAD. INSTRUMENTATION 1 HP 0.054 1.17 INSTALL RADIATION DETECTORS 820715 004289 041C016 VENT CRDM 2 MM 0.475 3.92 VENT CRDM/0BTAIN CAS & LIQUID SAMPLES

-*820715 004289 041C016 VENT CRDM 2 HP 0.394 4.48 VENT CRDM/0BTAIN GAS & LIQUID SAMPl ES

  • 820715 004289 D41C016 VENT CRDM 2 CN 0.375 4.00 VENT CRDM/0BTAIN GAS & LIQUID SAMPLES 820719 004326 D41C004.N-2 SYS ACTIVITY 1 HP 0.000 6.67 HOT TAP MS BLANK FLANGES

-*820719 004326 D41C004 .N-2 SYS ACTIVITY 6 CN 0.000 24.83 HOT TAP'HS BLANK FLANGES 820719 004321 D41C008 VENT & FILL S/G 1 OP 0.090 1.00 VENT HICH POINTS

  • 820719 004321 D41C008 VENT & FILL S/G 1 HP 0.088 1.33 VENT HIGH POINTS 820719 004314 041C014 TOOLS & EQUIPMENT 4 CN 0.753 9.50 STAGE CRDM TOOLS / INSTALL DUC TUBES 820719 004315 D41C017 LDSCR-UNCOUPLE & PARK 2 OP 0.296 3.75 VENT, UNCOUPLE & PARK LEADSCREW
  • 820719 004315 D41C017 LDSCR-UNCOUPLE & PARK 4 HP

.0.971 7.92 VENT, UNCOUPLE & PARK LEADSCREW

  • S20719 004315 D41C017 LDSCR-UNCOUPLE & PARK 1 ES 0.100 1.67 VENT, UNCOUPLE & PARK LEADSCREW LDSCR-UNCOUPLE & PARK 3 CN 0.420 6.08 VENT. UNC0UPLE & PARK LEADSCREW

'd,

  • 820719 004315 D41C017 820719 004316 D41C018 LEADSCREW-CUT & REMOVE 1 ES 0.259 2.08 REMOVE AND CUT LEADSCREW REMOVE AND CUT LEADSCREW

- CO 8820719 004316 D41C018 LEADSCREW-CUT & REMOVE 2 HP 0.502 4.00 e

  • 820719 004316 D41C018 LEADSCREW-CUT & REMOVE 2 CN 0.648 3.92 REMOVE AND CUT.LEADSCREW 320719 004334 D41C021 INCORE TV INSPECTION 1 IC 0.000 1.50 MARK CABLE FOR QUICK LOOK CAMERA JOB
  • 320719 004334 D41C021 INCOFF TV INSPECTION 1 CN 0.008 1.50 MARK CABLE FOR QUICK LOOK CAMERA JOB 820721 004338 D41C019 ESTBLSH EARMARK SYS 2 CN 0.502 4.75 REPLACE / RELOCATE RADIO ANTENNA 820721 004339 D41C021 INCORE TV INSPECTION 4 CN 0.676 9.67

. INSPECT UPPER END FITTING OF FUEL ASS *Y

  • 820721 004339 D41CO21 -INCORE TV INSPECTION 2 HP 0.283 3.25 INSPECT UPPER END FITTING OF FUEL ASS *Y
  • 820721 004339 D41C021 INCORE TV INSPECTION 1 CR 0.110 0.00

-INSPECT UPPER END FITTING OF FUEL ASS *Y >*820721 004339 D41C021 INCORE TV INSPECTION 1 ES 0.125 1.67 INSPECT UPPER END FITTING OF FUEL ASS'Y 820721 004340 D41C021 INCORE TV INSPECTION 2 IC 0.220 2.80 SET UP CAMERA ON RVHSS AND TEST

  • 820721 004340 D41C021 INCORE TV INSPECTION 1 CN 0.120 1.33

. SET UP CAMERA ON RVHSS AND TEST 820721 004337 D41CO22 INCORE LIQUID SAMPLE 1.HP 0.125 6.17 RCS LIQUID SAMPLE $820721 004337 D41C022 INCORE LIQUID SAMPLE 4 CM 0.457 2.08 RCS LIQUID SAMPLE 820727 004371 D41C004 N-2 SYS ACTIVITY 1 HP 0.000 6.00 HOT TAP MS BLANK FLANGES

  • 820727 004371 D41C004 N-2 SYS ACTIVITY 3 CN 0.005 15.42 HOT TAP MS BLANK FLANGES 820727 004375 D41CO22 INCORE LIQUID SAMPLE 1 HP 0.140 2.33 RCS LIQUID SAMPLE
  • 820727.004375 D41CO22 INCORE LIQUID SAMPLE 2 CN 0.406 4.50 RCS LIQUID SAMPLE 820730 004423 D41C016 VENT CRDM 2 CN 0.278 3.33 UNCAP / VENT / REMOVE SEISMIC RESTRAINT
  • 820730 004423 D41C016 VENT CRDM 1 HP 0.090 1.25 UNCAP / VENT / REMOVE SEISMIC RESTRAINT 820730 004421 D41C017 LDSCR-UNCOUPLE & PARK 4 IC 0.603 6.17 DISCONNECT POSITION INDICATOR CABLES 820730 004420 041C019 ESTBLSH EARMARK SYS 2 CN 0.150 2.00 EARMARK RADIO MAINTENANCE 820730 004426 D41C020 RIG LDSCR TO STORAGE 3 CN 0.390 3.50 RIG LEADSCREW OFF RVHSS 820730-004422 D41C021 INCORE TV INSPECTION 1 CN 0.117 1.58 RELOCATE VIDEO EQUIP FOR QUICK LOOK-2 820730 004443 D41C021 INCORE TV INSPECTION 2 IC 0.333 2.83 STAGE & TEST VIDEO EQUIP ON RVHSS
  • 820730 004443 D41CO21 INCORE TV INSPECTION 1 CN 0.148 1.42 STAGE & TEST VIDEO EQUIP ON RVHSS 820802 004424 D41C022 INCORE LIQUID SAMPLE 1 OP 0.150 1.42 RCS LIQUID SAMPLE
  • 820802 004424 041CO22 INCORE LIQUID SAMPLE 1 CM 0.118 1.42 RCS LIQUID SAMPLE

- _ _ _ _ - _ _ _ _ _ - _ _ _ - - - _.__- ~ _ ~ _ _ _..- -... _ ~ _. - - - _ - ~ ~. - _ -. -.. _ - - - DATE 022186 PAGE 4 PND. 3 .TMI-2 UNC: DOS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. ,............. T. A SK D. E. S.C.R I P T I O.N

  • D. A T.E... N U.MB E.R. N U.MBE.R.........AC. T. I V I T. Y........,.........E.N T RG.

C.O.D.E.. .....E.M..... HOUR S.......... R 3. 820804 004440 D41CO21 INCORE TV INSPECTION 6 CN 1.407 11.59 QUICK LOOK INSPECTION & CORE PROBE

  • 820804 004440 D41CO21 INCORE TV INSPECTION 1 CR 0.117 1.08 QUICK LOOK INSPECTION & CORE PROBE
  • 820804 034440 D41C021 INCORE TV INSPECTION 2 HP 0.334 4.33 QUICK LOOK INSPECTION & CORE PROBE 320805 004442 041C002 CHECK HIGH PT VENTS 1 HP 0.101 1,50 RAD SURVEY OF GENERAL AREA /RCS SAMPLES
  • 820805 004442 041C002 CHECK HIGH PT VENTS 2 CN 0.149 2.50 RAD SURVEY OF GENERAL AREA /RCS SAMPLES 820805 004441 D41C017 LDSCR-UNCOUPLE & PARK 2 ES 0.313 3,98 REMOVE CRDM/ UNCOUPLE & PARK LEADSCREW
  • 820805 004441 D41C017 LDSCR-UNCOUPLE & PARK 4 OP 1.321 6.83 REMOVE CRDM/ UNCOUPLE & PARK LEADSCREW
  • 820805 004441 D41C017 LDSCR-UNCOUPLE & PARK 6 HP 1.250 11.07 REMOVE CRDM/ UNCOUPLE & PARK LEADSCREW
  • 820805 004441 D41C017 LDSCR-UNCOUPLE & PARK 3 CN 1.101 5.17 REMOVE CRDM/ UNCOUPLE & PARK LEADSCREW 820306 004448 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.007 0.50 AIR SAMPLE AND GENERAL SURVEY 820806 004449 D41C018 LEADSCREW-CUT & REMOVE 1 ES 0.310 1,67 REMOVE AND CUT LEADSCREW
  • 820806 004449 D41C018 LEADSCPEW-CUT & REMOVE 2 HP 0.718 3.33 REMOVE AND CUT LEADSCREW
  • 820306 004449 D41C018 LEADSCREW-CUT & REMOVE 2 CN 0.905 3.33 REMOVE AND CUT LEADSCREW 820812 004489 D41C011 VENT & CAMPLE RX GAS 1 MM 0.122 1.43 CRDM GAS SAMPLE AND REMOVAL
  • 820812 004489 D41C011 VENT & SAMPLE RX GAS 1 HP 0.151 1.58 CRDM GAS SAMPLE AND REMOVAL

)! 820812 004478 D41C021 INCORE TV INSPECTION 2 IC 0.249 3.38 STAGE &' TEST CAMERA EQUIPMENT

  • 820812 004478 D41C021 INCORE TV INSPECTION 3 CN 0.401 4.95 STAGE & TEST CAMERA EQUIPMENT 820812 004480 D41CO21 INCORE TV INSPECTION 3 CN 0.759 8.00 CORE PROBE AND VIDED INSPECTION
  • 820812 004480 D41CO21 INCORE TV INSPECTION 1 CR 0.249 2.90 CORE PROPE AND VIDED INSPECTION 1820812 004480 D41C021 INCORE TV INSPECTION 1 HP 0.247 3.23 CORE PROBE AND VIDEO INSPECTION 8820812 004480 D41C021 INCORE TV INSPECTION 1 ES 0.232 2.58 CORE PROBE AND VIDED INSPECTION 820812 004477 D41C022 INCORE LIQUID SAMPLE 2 OP 0.331 3.05 RCS LIQUID SAMPLE 2, *820812 004477 D41CO22 INCORE LIQUID SAMPLE 1 HP 0.162 2.23 RCS LIQUID SAMPLE yy 820817 004517 D41C023 CLOSE UP CRDM 1 HP 0.163 1.92 RCS & CRDM SAMPLES /CLOSE CRDM
  • 820817 004517 D41C023 CLOSE UP CRDM 2 CN 0.322 3.75 RCS & CRDM SAMPLES /CLOSE CRDM y

820820 004549 D41C017 LDSCR-UNCOUPLE & PARK 3 OP 0.568 3.92 UNCOUPLE CRDM

  • 820820 004549 D41C017 LDSCR-UNCOUPLE & PARK 5 CN 0.843 7.25 UNCOUPLE CRDM 820820 004587 041C023 CLOSE UP CRDM 3 HP 0.552 6.27 CRDM CLOSURE /RCS SAMPLE

$820820 004547 D41CO23 CLOSE UP CRDM 5 CN 0.862 9.98 CRDM CLOSURE /RCS SAMPLE 820830 004604 D41C011 VENT & SAMPLE RX GAS 2 HP 0.331 3.67 CRDM GAS SAMPLE AND REMOVAL

  • 820830 004604 D41C011 VENT & SAMPLE RX GAS 4 CN 0.597 5.60 CRDM GAS SAMPLE AND REMOVAL 820907 004655 D41C022 INCORE LIQUID SAMPLE 1 OP 0.120 0.92 RCS LIQUID SAMPLE /CRDM GAS SAMPLE
  • $20907 004655 D41C022 INCORE LIQUID SAMPLE 2 HP 0.264 3.01 RCS LIQUID SAMPLE /CRDM GAS SAMPLE
  • S20907 004655 D41C022 INCORE LIQUID SAMPLE 1 CN 0.128 1.35 RCS LIQUID SAMPLE /CRDM GAS SAMPLE 820914 004707 D41C011 VENT & SAMPLE RX GAS 3 HP 0.373 4.42 RAD SURVEY /RCS LIQUID & GAS SAMPLES

$820914 004707 D41C011 VENT & SAMPLE RX GAS 1 OP 0.220 2.83 RAD SURVEY /RCS LIQUID & GAS SAMPLES 820922 004752 D41C011 VENT & SAMPLE RX GAS 2 OP 0.254 2.55 RAD SURVEY /RCS LIQUID & GAS SAMPLES 820922 004752 D41C011 VENT & SAMPLE RX GAS 4 HP 0.737 4.98 RAD SURVEY /RCS LIQUID & GAS SAMPLES 820928 004805 041C011 VENT & SAMPLE RX GAS 2 OP 0.377 5,67 RCS GAS SAMPLE AND REMOVAL 820928 004802 041C022 INCORE LIQUID SAMPLE 2 HP 0.381 4.33 RCS LIQUID SAMPLE /CRDM GAS SAMPLE 3

  • 820928 OC4802 D41C022 INCORE LIQUID SAMPLE 1 OP 0.150 2.00 RCS LIQUID SAMPLE /CRDM GAS SAMPLE r

821006 004857 D41C022 INCORE LIQUID SAMPLE 1 HP 0.175 2.00 RCS LIQUID SAMPLE /CRDM GAS SAMPLE

  • 821006 0C4857 041C022 INCORE LIQUID SAMPLE 1 OP 0.168 1.93 RCS LIQUID SAMPLE /CRDM GAS SAMPLE 821013 0C4896 D41C022 INCORE LIQUID SAMPLE 1 HP 0.132 1.58 RCS LIQUID SAMPLE i
  • 821013 004396 041C022 INCORE LIQUID SAMPLE 1 OP 0.120 1.50 RCS LIQUID SAMPLE 821020 0C4943 D41C002 CHECK HIGH PT VENTS 1 HP 0.154 1.85 RADIATION SURVEYS /RCS AND CRDM SAMPLES I

8821020 OC4943 D41C002 CHECK HIGH PT VENTS 2 OP 0.115 1.73 RADIATION SURVEYS /RCS AND CRDM SAMPLES 4 821103 OC5033 D41C015 HOIST /RIGNG/ PLATFORM-4 CN 0.436 8.75 INSTALL HIGH LINE ON P.C. GIRDER 821103 0C5032 D41CO22 INCORE LIQUID SAMPLE 1 HP 0.141 1.93 RCS LIQUID SAMPLE /CRDM GAS SAMPLE

  • 821103 0C5032 041C022 INCORE LIQUID SAMPLE 1 OP 0.118 1.30 RCS LIQUID SAMPLE /CRDM GAS SAMPLE J

j i

DATE 022186 PAGE 5 PNO. 4 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP, TASK ......E.R..........T.IVITY............ .......................................................D.ES.CRIPTION NUMB AC ENTRG CODE REM. HOURS.

  • DATE.hUMBER.

821110 005081 D41C025.RMOV LDSCR FROM CTMT 3 HP 0.541 8.12. MOVE LEADSCREWS TO

  • B' D-RING
  • 821110 005081 D41C025 RMOV LDSCR FROM CTMT 5 CN 0.824 13.15 MOVE LEADSCREWS TO

'B' D-RING 821110 005082 041C025 RMOV LDSCR FROM CTMT 5 RP 0.678 9.23 LEADSCREW CUTTING 821112 005092 D41C025 RMOV LDSCR FROM CTMT 5 CN 0.738 8.83 SET UP LEADSCREW CUTTING AREA 821115 005109 D41CO25 RMOV LDSCR FROM CTMT 2 HP 0.324 5.00 CUT LDWER HALF OF LEADSCREW H8

  • 821115 005109 D41C025 RMOV LDSCR FROM CTMT 6 CN 0.949 16.22 CUT LOWER HALF OF LEADSCREW H8 821115 005113 D41CO25 RMOV LDSCR FROM CTMT 4 RP 0.010 3.75 TRANSPORT LEADSCREW SAMPLES & PACKAGE
  • 821115 005113 D41C025 RMOV LDSCR FROM CTMT 1 CN 0.000 0.73 TR ANSPORT LE ADSCREW SAMPLES & PACKAGE 821117 005127 D41C022 INCORE LIQUID SAMPLE 1 OP 0.135 1.95 RCS LIQUID SAMPLE /CRDM GAS SAMPLE

$821117 005127 D41C022 INCORE LIQUID SAMPLE 2 HP 0.356 4.90 RCS LIQUID SAMPLE /CRDM GAS SAMPLE 821117 005137 D41C025 RMOV LCSCR FROM CTMT 1 RP 0.005 1.73 PACKAGE LEADSCREW FOR SHIPPING 821118 005131 D41C017 LDSCR-UNCOUPLE & PARK 2 CN 0.233 4.08 UNCOUPLE CRDM 821119 005148 041C025 RMOV LDSCR FROM CTMT 3 HP 0.031 5.88 GAMMA SCAN OF LEADSCREW SECTIONS

  • 821119 005148 D41C025 RMOV LDSCR FROM CTMT 3 CN 0.116 8.63 GAMMA SCAN OF LEADSCREW SECTIONS 821122 005157 D20A001 RX DISASSEMBLY PREP 1 HP 0.267 2.40 RADIATION SURVEY / JOB COVERAGE 821122 005154 D41C017 LDSCR-UNCOUPLE & PARK 1 HP 0.058 1.12 CONFIRM APSR UNCOUPLING - R0034
  • 821122 005154 041C017 LDSCR-UNCOUPLE & PARK 2 CN 0.127 1.98 CONFIRM APSR UNCOUPLING - R0034 821122 005163 041C025 RMOV LDSCR FROM CTMT 1 CN 0,017 4.73 GAMMA SCAN OF LEADSCREWS 821122 005168 D41C025 RMOV LDSCR FROM CTMT 2 RP 0.030 4.70 PACKAGE LEADSCREWS FOR SHIPPING
  • 821122 005168 D41C025 RMOV LDSCR FROM CTMT 1 HP 0.015 2.73 PACKAGE LEADSCREWS FOR SHIPPING 821124 005183 D41CO22 INCORE LIQUID SAMPLE 1 HP 0.250 2.07 RCS LIQUID SAMPLE
  • 821124 C05183 bSIC022 INCORE LIQUID SAMPLE 1 OP 0.097 1.42 RCS LIQUID SAMPLE 821202 C05223 D41CO22 INCORE LIQUID SAMPLE 1 HP 0.190 2.65 RCS LIQUID SAMPLE /CRDM GAS SAMPLE n3 *821202 005223 D41C022 INCORE LIQUID SAMPLE 1 OP 0.153 2.15 RCS LIQUID SAMPLE /CROM GAS SAMPLE C3 821208 005274 D41C017 LDSCR-UNCOUPLE & PARK 2 ES 0.361 5.03 RAD SURVEYS /APSR PARKING /LDSCR VERIF.

8

  • 821208 005274 041C017 LDSCR-UNCOUPLE & PARK 2 HP 0.318 5.67 RAD SURVEYS /APSR PARKING /LDSCR VERIF.
  • 821208 005274 D41C017 LDSCR-UNCOUPLE & PARK 4 CN 0.704 9.93 RAD SURVEYS /APSR PARKING /LDSCR VERIF.

821208 005272 D41CO22 INCORE LIQUID SAMPLE 1 HP 0.217 2.43 RCS LIQUID SAMPLE

  • 821208 005272 D41C022 INCORE LIQUID SAMPLE 1 OP 0.081 1.37 RCS LIQUID SAMPLE 321208 005271 D41C023 CLOSE UP CRDM 4 MM 0.811 9.97 CRDM MOTOR TUBES CLOSURE 321209 C05283 D20A001 RX DISASSEMBLY PREP 3 MM 0.346 4.88 INSPECT HEAD LIFT EQUIPMENT
  • 821209 C05283 D20A001 RX DISASSEMBLY PREP 3 CN 0.420 5.22 INSPECT HEAD LIFT EQUIPMENT 821210 005297 041C017 LDSCR-UNCOUPLE & PARK 1 ES 0.156 2.43 LEADSCREW VERIFICATION
  • 821210 005297 D41C017 LDSCR-UNCOUPLE & PARK 1 HP 0.146 2.50 LEADSCREW VERIFICATION
  • 821210 C05297 D41C017 LDSCR-UNC00PLE& PARK 2 CN 0.321 4.85 LEADSCREW VERIFICATION 821213 005306 D41C017 LDSCR-UNCOUPLE & PARK 2 ES 0.266 4.35 LEADSCREW VERIFICATION
  • 821213 005306 D41C017 LDSCR-UNCOUPLE & PARK 2 HP 0.295 4.80 LEADSCREW VERIFICATION
  • 821213 C05306 D41C017 LDSCR-UNCOUPLE & PARK 4 CN 0.472 8.83 LEADSCREW VERIFICATION 821213 005326 D41C025 RMOV LOSCR FROM CTMT 7 HP 0.425 16.58 DECON TEST OF LEADSCREW H8
  • 821213 005326 D41C025 RMOV LDSCR FROM CTMT 5 ES 0.418 13.20 DECON TEST OF LEADSCREW HS 821213 005328 D41C025 RMOV LDSCR FROM CTMT 4 RP 0.013 10.52 LEADSCREW DECON/ TRANSPORT / ANALYSIS 3821213 005328 041CO25 RMOV LDSCR FROM CTMT 7 CM 0.002 20.47 LEADSCREW DECON/ TRANSPORT / ANALYSIS
  • 821213 005328 D41C025 RMOV LDSCR FROM CTMT 1 ES 0.007 2.05 LEADSCREW DECON/ TRANSPORT / ANALYSIS
  • 821213 005328 D41C025 RMOV LDSCR FROM CTMT 1 HP 0.013 3.33 LEADSCREW DECON/ TRANSPORT / ANALYSIS 821214 005320 D41C023 CLOSE UP CRDM 2 MM 0.235 3.22 CROM MOTOR TUBES CLOSURE
  • 821214 005320 041C023 CLOSE UP CRDM 2 CN 0.225 2.88 CRDM MOTOR TUBES CLOSURE 821216 005339 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.118 1.93 RX VESSEL INTERNAL RADIATION MEASUREMENT 821216 C05339 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.135 1.63 RX VESSEL INTERNAL RADIATION MEASUREMENT 821216 C05338 041CO24 VENT & FILL RCS 1 OP 0.196 1.85 RCS LIQUID SAMPLE /RCS REFILL 3821216 C05338 D41C024 VENT & FILL RCS 1 HP 0.150 1.90 RCS LIQUID SAMPLE /RCS REFILL

DATE 022186 PAGE 6 PNO. 5 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. .............. T A S K.. D. E. S. C. R I P T I O N..........,

  • D. AT E... NUMBE R...... B E. R.......... C. T I V.I T Y.................. E. N T R G. C O.D. E.,....E.M...

NUM A R .... U. R S...,....... HO 821217 005354 D20A001 RX DISASSEMBLY PREP 1 CN 0.075 1.25 INSPECT HEAD LIFT EQUIPMENT 821217 005352 D41CO24 VENT & FILL RCS 1 HP 0.231 2.07 RCS REFILL

  • 821217 005352 D41C02A VENT & FILL RCS 1 OP 0.213 2.02 RCS REFILL 821219 005366 D41C009 IN-CTMT SHIELDING 3 OP 0.573 7.05 DECON PLUG SHIELD / COAT FLOOR DRAINS
  • 821219 005366 041C009 IN-CTMT SHIELDING 1 HP 0.180 2.28 DECON PLUG SHIELD / COAT FLOOR DRAINS
  • 871219 005366 D41C009 IN-CTMT SHIELDING 1 CN 0.221 2.32 DECON PLUG SHIELD / COAT FLOOR DRAINS 821220 005362 D41C024 VENT & FILL RCS 1 HP 0.070 1.13 RCS REFILL /CRDM INSPECTION 821221 005380 D41C009 IN-CTMT SHIELDING 1 HP 0.135 1.00 HP SURVEY / TRASH REMOVAL 821221 005378 041C024 VENT & FILL RCS 1 QA 0.088 1.32 RCS REFILL INSPECTION 821223 005394 D20A001 RX DISASSEMBLY PREP 2 CN 0.352 4.40 WLKDWN REFUEL POOL / PHOTO FUEL XFER EQUIP

$821223 008394 D20A001 RX DISASSEMBLY PREP 1 HP 0.180 2.05 WLKDWN REFUEL POOL / PHOTO FUEL XFER EQUIP 821228 005420 D41C003 VENT & FILL S/G 1 OP 0.100 1.23 VENT OTSG A 8821228 005420 D41C003 VENT & FILL S/G 1 HP 0.052 0.67 VENT OTSG A 821229 005430 041C005 ELECTRICAL SUPPORT 6 CN 0.825 13.50 TEMPORARY POWER INSTALLATION 821230 005439 D41C008 VENT & FILL S/G 1 OP 0.050 0.58 VENT OTSG A - SECONDARY SIDE 821230 005437 D41C009 IN-CTMT SHIELCING 2 OP 0.067 1.28 LEAD &-PLYWOOD SHIELDING OVER FLR DRAINS 3821230 005437 D41C009 IN-CTMT SHIELDING 1 UM 0.025 0.75 LEAD & PLYWOOD SHIELDING OVER FLR DRAINS

  • 821230 005437 041C009 IN-CTMT SHIELDING 1 CN 0.031 0.75 LEAD & PLYWOOD SHIELDING OVER FLR DRAINS 830104 005462 041C005 ELECTRICAL SUPPORT 3 CN 0.465 4.95 ERECT SCAFFOLDING-ELEV 319' 330105 005476 D41C005 ELECTRICAL SUPPORT 2 CN 0.188 4.18 TEMPORARY POWER INSTALLATION 830106 005433 D41C004 N-2 SYS ACTIVITY 1 HP 0.228 1.70 CONNECT N-2 TO

'A*&*D' VALVE LINE-0TSG B

  • 830106 005493 D41C004 N-2 SYS ACTIVITY 3 OP 0.431 5.43 CONNECT N-2 TO

'A'&*D' VALVE LINE-0TSG B B 830107 005503 041C015 HOIST /RIGNG/ PLATFORM 4 CN 0.579 6.58 REPLACE RVHSS HOIST / INSTALL HANDRAIL h3 830110 005510 0410001 PRE HEAD LIFT EXAM 2 CH 0.690 3.18 RB BASEMENT SLUDGE SAMPLES

  • 830110 005510 D41D001 PRE HEAD LIFT EXAM 1 UM 0.150 0.80 RB BASEMENT SLUDGE SAMPLES 8
  • 830110 005510 D410001 PRE HEAD LIFT EXAM 1 HP 0.300 1.65 RB BASEMENT SLUDGE SAMPLES 830112 005541 020A001 RX DISASSEMBLY PREP 2 CN 0.103 2.92 PHOTOGRAPH FUEL TRANSF ER EQUIPMENT
  • 830112 005541 D20A001 RX DISASSEMBLY PREP 1 HP 0.054 1.35 PHOTOGRAPH FUEL TRANSFER EQUIPMENT 830124 005636 022E012 CANAL ACCESS 4 CN 0.114 11.30 ASSEMBLE SCAFFOLDING IN REFUEL CANAL 830127 005669 D22E001 NEUTRON SHIELD TANKS 2 OP 0.336 3.15 REMOVE NEUTRON SHIELDS
  • 830127 005669 022E001 NEUTRON SHIELD TANKS 2 CM 0.335 5.05 REMOVE NEUTRON SHIELDS 2830127 005669 D22E001 NEUTRON SHIELD TANKS 2 HP 0.330 4.37 REMOVE NEUTRON SHIELDS
  • 830127 005669 D22E001 NEUTRON SHIELD TANKS 1 RP 0.150 1.58 REMOVE NEUTRON SHIELDS
  • 830127 005669 D22E001 NEUTRON SHIELD TANKS 3 MM 0.627 7.00 REMOVE NEUTRON SHIELDS 830127 005670 D22E012 CANAL ACCESS 3 CN 0.476 7.82 INSTALL SCAFFOLD-STRWELL TO REFUEL CANAL 830127 005668 041C015 HOIST /RIGNG/ PLATFORM 4 CN 0.580 6.68 REPLACE RVHSS HOISTS 830204 035746 041C005 ELECTRICAL SUPPORT 4 CN 0.475 4.98 TEMPORARY POWER FOR HIGH REACH INSPECT'N 830209 035781 022E012 CANAL ACCESS 1 OP 0.078 1.12 MOVE AUX FUEL HANDLING BRIDGE TROLLEY 830209 035783 D41C001 IN-CTMT RAD SURVEYS 1 OP 0.100 1.35 CLOSE VENT VALVES - OTSG A & B 830209 035783 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.222 1.75 CLOSE VENT VALVES - OTSG A & B 830211 035802 D22E004 CANAL SEAL PLATE 3 CN 0.698 8.05 INSPECT CANAL SHIELD PLATE / SEAL LEDGE

$830211 035802 022E004 CANAL SEAL PLATE 1 HP 0.070 1.37 INSPECT CANAL SHIELD PLATE / SEAL LEDGE 830214 005827 D22E014 TEMPORARY POWER 4 CN 0.010 5.30 RUN CONDUIT / PULL WIRE IN OVERHEADS

  • 830214 005827 D22E014 TEMPORARY POWER 2 HP 0.005 2.88 RUN CONDUIT / PULL WIRE IN OVERHEADS 830215 005834 D22E001 NEUTRON SHIELD TANKS 8 CN 1.041 16.20 REMOVE NEUTRON SHIELD TANKS FROM CTMT 830216 005842 D41D001 PRE HEAD LIFT EXAM 2 CN 0.262 2.70 AS-BUILT RVHSS SHIELDING 830217 005854 022E002 RX HEAD INSULATION 3 MM 0.527 5.73 REMOVE RX HEAD THER IhSUL/ MOVE TO 305 EL
  • 830217 005854 D22E002 RX HEAD INSULATION 2 OP 0.277 3.05 REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL
  • 830217 005854 022E002 RX HEAD INSULATION 2 RP 0.416 3.73 REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL
  • 830217 005854 022E002 RX HEAD INSULATION 1 CM 0.170 2.17 REMOVE RX HEAD THER IhSUL/ MOVE TO 305 EL

DATE 022186 PAGE 7 PNO. 6 .TMI-2 UNC-DDS - ACTIVITY REPORT - RE ACTOR DEFUEL & DISASSEMBLY M 286 D RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. TA ..NLMBER z.............. NUMBE.R...........IVITY...................................................................S.K DESC.RIPTION ACT ENTRG. CODE REM HOURS

  • DATE 2 HP

. 0.274. 4.83 REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL

  • 830217 005854 D22E002.RX HEAD INSULATION 830218 005867 D22E014 TEMPORARY POWER 11 CN 0.004 16.40 PULL CABLE THROUGH TRAYS & CONDUIT 830223 005899 D22E010 RCS WATER LEV. CNTRL 1 HP 0.444 1.47

'A' D-RING TUBING ON RC-V-110 & RC-V-111

  • 830223 005899 D22E010 RCS WATER LEV CNTRL 4 CN 1.239 5.95
  • A' D-RING TUBING ON RC-V-110 & RC-V-111 830301 005953 D22E009 UNDERHEAD DATA ACQUI 2 RP 0.010 3.50 PREP ION CHAMBER FOR QUICK-SCAN RAD MEAS 2830301 005953 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.010 3.17 PREP ION CHAM 8ER FOR QUICK-SCAN RAD MEAS 830302 005960 D22E010 RCS WATER LEV. CNTRL 1 OP 0.122 1.12 RCS DRAIN DDWN 830308 006011 D22E001 NEUTRON SHIELD TANKS 5 CN 0.915 9.43 INSTALL REMOVA8LE BEAM AND GRATING 830311 006025 D22E010 RCS WATER LEV. CNTRL 2 CN 0.340 1.65 MANOMETER INSTALLATION RV/ ADD SAMP LINE 830315 006057 D22E001 NEUTRON SHIELD TANKS 17 CN 3.103 35.27 CLEAN HEADLIFT PINS 830317 006074 022E001 NEUTRON SHIELD TANKS 1 IC 0.169 1.28 TROUBLESHOOT / REPAIR SOURCE RANGE INST.

830321 006087 D41C025 RMOV LDSCR FROM CTMT 1 HP 0.094 1.35 REMOVE LEADSCREW SECTIONS FROM CTMT

  • 830321 006087 D41C025 RMOV LDSCR FROM CTMT 1 CN 0.097 1.33 REMOVE LEADSCREW SECTIONS FROM CTMT 830321 006099 D41C025 RMOV LDSCR FROM CTMT 4 RP 0.035 20.12 GAMMA SCAN & PACKAGE LEADSCREW SECTIONS
  • 830321 006099 D41CO25 RMOV LDSCR FROM CTMT 2 CN 0.001 7.87 GAMMA SCAN & PACKAGE LEADSCREW SECTIONS
  • 830321 006099 D41C025 RMOV LDSCR FROM CTMT 1 HP 0.014 4.77 GAMMA SGAN & PACKAGE LEADSCREW SECTIONS 830321 006112 D41C025 RMOV LDSCR FROM CTMT 1 UM 0.000 1.33 LOAD LDSCR PACKAGE INTO SHIPPING CASK
  • 830321 006112 D41C025 RMOV LDSCR FROM CTMT 3 OP 0.000 4.02 LOAD LDSCR PACKAGE INTO SHIPPING CASK
  • 830321 006112 D41C025 RMOV LDSCR FROM CTMT 2 CR 0.000 2.67 LOAD LDSCR PACKAGE INTO SHIPPING CASK
  • 830321 006112 041C025 RMOV LDSCR FROM CTMT 1 HP 0.000 1.72 LOAD LDSCR PACKAGE INTO SHIPPING CASK 830323 006124 D22E003 RV STUD REMOVAL 2 MM 0.195 1.97 LUBE STUD THREADS ON RV HEAD 830325 006133 D22E018 HEAD STORAGE STAND 1 QA 0.159 1.97 HEAD STORAGE STAND INSPECTION 830406 006217 D20A001 RX DISASSEMBLY PREP 4 CN 0.902 11.07 INSTALL GANTRY CRANE RUNNING RAIL

' 830407 006223 020A001 RX DISASSEMBLY PREP 2 CN 0.210 3.50 TAKE ELEVATIONS FOR CRANE $ 830407 006224 D20A001 RX DISASSEMBLY PREP 2 CN 0.201 2.57 CLEAN / INSPECT LIFTING LUGS e 830420 006309 D41D001 PRE HEAD LIFT EXAM 1 IC 0.000 0.13 SURVEY NEUTRON SOURCE 830421 006316 022E004 CANAL SEAL PLATE 2 CN 0.261 6.33 INSPECT TRANSPORT TU8E&NEUT SHLD TK SUPP 830427 006357 D22E004 CANAL SEAL PLATE 2 CN 0.242 2.62 MOVE NEUTRON SHIELD TANKS 830428 006363 D22E010 RCS WATER LEV. CNTRL 2 CN 0.288 3.13 MANOMETER INSTALLATION

  • 8*

OTSG 830429 006373 D20A001 RX DISASSEMBLY PREP 1 OA 0.114 1.43 INSPECT LIFTING LUGS ON REAC10R VESSEL 830429 006381 035E001 SHIELD RVHSS 2 CN 0.257 3.53 REMOVE RVHSS SHLDING FRAME INTERFERENCE

  • 830429 006381 035E001 SHIELD RVHSS 1 HP 0.150 1.85 REMOVE RVHSS SHLDING FPAME INTERFERENCE 830502 006397 C35E001 SHIELD RVHSS 4 CN 0.522 7.05 REMOVE RVHSS SHLDING FPAME INTERFERENCE 830502 006398 D35E001 SHIELD RVHSS 1 MM 0.080 2.10 INSTALL UPPER SHIELD SUPPORT ON RV HEAD
  • 830502 006398 D35E001 SHIELD RVHSS 10 CN 1.519 22.82 INSTALL UPPER SHIELD SUPPORT ON RV HEAD 830502 006409 D35E001 SHIELD RVHSS 5 CN 0.262 4.28 INSTALL LDWER SHIELD SUPPORT ON RV HEAD 830512 006481 D22E016 CABLE DISCONNECT 3 EL 0.363 6.78 HEAD SERVICE STRUCTURE POWER DISCONNECT 830513 006495 D22E003 RV STUD REMOVAL 1 MM 0.071 1.42 Lb8E STUDS ON RV HEAD AND INTERFACE 830513 006497 D22E030 REMOVE HEAD 1 RP 0.157 2.38 SOURCE CHECK NUC INSTRUMENTATION J0004
  • 830513 006497 D22E030 REMOVE HEAD 1 CN 0.155 2.33 SOURCE CHECK NUC INSTRUMENTATION J0004
  • 830513 006497 D22E030 REMOVE HEAD 1 HP 0.173 2.48 SOURCE CHECK NUC INSTRUMENTATION J0004 830520 006548 D20A001 RX DISASSEMBLY PREP 4 CN O.549 7.78 INSTALL ANCHOR BOLTS AND RUNWAY RAIL 830520 006549 D22E030 REMOVE HEAD 1 HP 0.108 2.60 SOURCE CHECK NUC INSTRUMENTATION J0004
  • 830520 003549 D22E030 REMOVE HEAD 2 IC 0.284 5.37 SOURCE CHECK NUC INSTRUMENTATION J0004 830524 006586 D20F001 FUEL CANAL MODS.

2 CN 0.013 1.82 DRILL HANGER. RUN HOSE-SFP2 TO PENET 565 830524 006580 D22E001 NEUTRON SHIELD TANKS 2 CN 0.246 3.67 AS-8UILT GANTRY CRANE RAIL BOLTS 830524 006581 D22E005 CRDM REMOVAL 2 RP 0.103 2.37 GENERAL ACTIVITY WORK PACKAGE 830526 006594 020A001 RX DISASSEMBLY PREP 2 CN 0.242 4.07 REPAIR HOLES IN CONCRETE 830527 006609 D22E010 RCS WATER LEV. CNTRL 2 IC 0.002 2.85 CHECK CALIB ON R8 SUMP LEVEL TRANSMITTER 830603 066641 D22E030 REMOVE HEAD 1 CN 0.099 1.23 IN CONTAINMENT INSPECTION

DATE 022186 PAGE 8 PNO. 7 .THI-2 UNC-DOS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEM8LY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP.

  • D.AT.E... NUMBE.R...... B. E.R....r......C.TIVITY......................E.N T R G.. C.OD.E...

NUM A ...RE.M...... H. OU. R S........................... D. E. S. C. R I P T. I. O. N............ TASK . MEASURE WELDS ON HEAD HANDLING FIXTURE 830604 006574 D20A001 RX DISASSEMBLY PREP 1 QA 0.139 2.02 $830603 006674 D20A001 RX DISASSEMBLY PREP 1 CN 0.112 2.05 MEASURE WELDS ON HEAD HANDLING FIXTURE 830608 006677 D20F001 FUEL CANAL MODS. 3 CN 0.000 2.95 RUN HOSE TO PENET 565, BOLT UP FLANGE 830624 006797 D20A001 RX DISASSEMBLY PREP 3 CN 0.484 6.58 PHOTOGRAPH / INSPECT HEAD HANDLING FIXTURE

  • S30624 006797 D20A001 RX DISASSEMBLY PREP 1 QA 0.209 2.62 PHOTOGRAPH / INSPECT HEAD HANDLING FIXTURE 830628 006829 D20A001 RX DISASSEMBLY PREP 1 QA 0.172 2.47 INSPECT WELDS ON HEAD HANDLING FIXTURE
  • 830628 006829 020A001 RX DISASSEMBLY PREP 1 CN 0.171 2.73 INSPECT WELDS ON HEAD HANDLING FIXTURE 830701 006850 022E004 CANAL SEAL PLATE 2 CN 0.289 2.68 MEASURE CANAL SEAL PLATE LEDGE
  • 830701 006850 D22E004 CANAL SEAL PLATE 1 HP 0.156 1.62 MEASURE CANAL SEAL PLATE LEDGE 830705 006859 D20A001 RX DISASSEMBLY PREP 1 CN 0.106 1.33 INSPECT WELDS ON HEAD HANDLING FIXTURES

$830705 006859 D20A001 RX DISASSEMBLY PREP 1 QA 0.107 1.28 INSPECT WELDS ON HEAD HANDLING FIXTURES 830706 006884 D41C018 LEADSCREW-CUT & REMOVE 3 EL 0.415 5.87 CUT LEADSCREWS/ SET UP CUTTING AREA 8830706 006884 D41C018 LEADSCREW-CUT & REMOVE 6 HP 0.740 12.10 CUT LEADSCREWS/ SET UP CUTTING AREA

  • 830706 006884 D41C018 LEADSCREW-CUT & REMOVE 1 MM 0.081 1.37 CUT LEADSCREWS/ SET UP CUTTING AREA
  • 830706 006884 D41C018 L E ADSCREW-CU T&RE MOVE 19 CN 0.219 36.43 CUT LEADSCREWS/ SET UP CUTTING ARE A 830706 006885 D41C025 RMOV LDSCR FROM CTMT 1 RP 0.130 2.12 LEADSCREW CUTTING AREA CLEANUP
  • 830706 006885 D41CO25 RMOV LDSCR FROM CTMT 1 CM 0.110 2.02 LEADSCREW CUTTING AREA CLEANUP
  • 830706 006885 041C025 RMOV LDSCR FROM CTMT 1 EL 0.154 2.08 LEADSCREW CUTTING AREA CLEANUP
  • 830706 006835 041C025 RMOV LDSCR FROM CTMT 1 CN 0.093 1.93 LEADSCREW CUTTING AREA CLEANUP 830707 006893 041C025 RMOV LDSCR FROM CTMT 12 RP 0.191 75.15 RECEIVE / GAMMA SCAN / PACKAGE LEADSCREWS
  • 830707 006893 041C025 RMOV LDSCR FROM CTMT 5 UM 0.021 29.82 RECEIVE / GAMMA SCAN / PACKAGE LEADSCREWS
  • 830707 006893 041C025 RMOV LDSCR FROM CTMT 6 HP 0.133 49.23 RECE1VE/ GAMMA SCAN / PACKAGE LEADSCREWS g
  • 830707 006893 041CO25 RMOV LDSCR FROM CTMT 6 CN 0.015 50.18 RECEIVE /GA;1MA SCAN / PACKAGE LE ADSCREWS ns

$30707 006896 041C025 RMOV LDSCR FROM CTMT 5 UM 0.005 6.47 LOAD LEADSCREW DRUMS INTO SHIPPING CASK La *830707 006896 041C025 RMOV LDSCR FROM CTHT 9 OP 0.005 16.25 LOAD LEADSCREW DRUMS INTO SHIPPING CASK e

  • S30707 006896 041C025 RMOV LDSCR FROM CTMT 6 CR 0.012 10.65 LOAD LEADSCREW DRUMS INTO SHIPPING CASK

$830707 006896 D41C025 RMOV LDSCR FROM CTMT 2 HP 0.007 6.08 LOAD LEADSCREW DRUMS INTO SHIPPING CASK

  • 830707 006896 D41C025 RMOV LDSCR FROM CTMT 2 CN 0.008 3.98 LOAD LEADSCREW DRUMS INTO SHIPPING CASK 830711 006910 D22E018 HEAD STORAGE STAND 2 CN 0.082 1.60 REMOVE NUTS FROM ANCHOR BOLTS-HEAD STAND 830711 006909 D41C018 LEADSCREW-CUT & REMOVE 2 HP 0.268 4.03 CUT LEADSCREWS
  • 830711 006909 D41C018 LEADSCREW-CUT & REMOVE 1 MM 0,140 2.12 CUT LEADSCREWS

$830711 006909 D41C018 LEADSCREW-CUT & REMOVE 5 CN 0.831 11.82 CUT LEADSCREWS 830712 006938 D20E001 RD&D SUPP-0UTS CTMT 4 RP 0.000 3.36 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX $830712 006938 D20E001 RD&D SUPP-0UTS CTMT 1 EL 0.005 2.90 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX $830712 006938 020E001 RD&D SUPP-0UTS CTMT 1 UM 0.005 2.90 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX

  • 830712 006938 D20E001 RD&D SUPP-0UTS CTMT 1 MM 0.000 2.90 MOVE HIGH RAD TPASH-ANTER0OM TO 305 AUX

$830712 006938 D20E001 RD&D SUPP-0UTS CTMT 2 CN 0.000 1.73 MOVE HIGH RAD TiASH-ANTEROOM TO 305 AUX

  • 830712 006938 D20E001 RD&D SUPP-0UTS CTMT 1 RC 0.005 3.63 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX 830712 006933 D41C025 RMOV LDSCR FROM CTMT 1 CN 0.175 1.97 LEADSCREW CUTTING AREA CLEANUP
  • 830712 006933 D41C025 RMOV LDSCR FROM CTMT 2 CM 0.182 2.95 LEADSCREW CUTTING AREA CLEANUP

$830712 006933 041C025 RMOV LDSCR FRDM CTMT 1 RP 0.135 1.95 LEADSCREW CUTTING AREA CLEANUP 830714 006949 D22E018 HEAD STORAGE STAND 2 CN 0.203 2.12 REMOVE NUTS FROM ANCHOR BOLTS-HEAD STAND 830715 006963 D22E013 SERVICE AIR 4 CN 0.127 2.82 INSTALL SERVICE AIR & SUMP ISOLATION 830720 007001 D22E010 RCS WATER LEV. CNTRL 1 RP 0.088 1.12 INSP EQUIP 'D' RINGS / PREP FOR RCS DRAIN 830722 007025 D22E010 RCS WATER LEV. CNTRL 1 HP 0.001 2.05 VERIFY DW-V-195 POSITION & BLANK FLANGE $830722 007025 022E010 RCS WATER LEV. CNTRL' 1 OP 0.000 1.30 VERIFY DW-V-195 POSITION & BLANK FLANGE 830723 007031 D20E001 RD&D SUPP-0UTS CTMT 1 HP 0.043 1.03 VALVE LINE-UP

  • 830723 007031 D20E001 RD&D SUPP-0UTS CTMT 1 OP 0.005 1.05 VALVE LINE-UP 830724 007037 D22E010 RCS WATER lev. CNTRL 1 CN 0.050 1.62 CHECK VALVE POSITION /WDL-V-508, 935, 509
  • S30724 007037 D22E010 RCS WATER LEV. CNTRL 1 OP 0.055 1.60 CHECK VALVE POSIT 10N/WDL-V-508, 935, 509

DATE 022186 PAGE 9 PNO. 8 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. ................SK.. DESCRIPTION

  • DATE.. NUMBER. NUMBER ACTIVITY HOURS.

TA 330725 007032 D22E010 RCS WATER LEV. CNTRL . ENTRG.CODE..... REM 1 OP 0.179 2.22 RCS DRAINDOWN - TOP OF CFT-A

  • 830725 007032 D22E010 RCS WATER LEV. CNTRL 1 RP 0.214 2.03 RCS DRAINDOWN - TOP OF CFT-A
  • 830725 007032 D22E010 RCS WATER LEV. CNTRL 1 HP 0.237 2.20 RCS DRAINDOWN - TOP OF CFT-A 830726 007060 D22E001 NEUTRON SHIELD TANKS 4 CN 0.420 6.73 REMOVE NEUT SHIELD TKS FRCM REFUEL CANAL
  • 830726 007060 D22E001 NEUTRON SHIELD TANKS 1 EL 0.110 1.77 REMOVE NEUT SHIELD TKS FROM REFUEL CANAL 830726 007056 D22E010 RCS WATER LEV. CNTRL 2 OP 0.151 2.22 RCS DRAINDOWN - TOP OF RVHSS
  • 830726 007056 D22E010 RCS WATER LEV. CNTRL 1 HP 0.069 1.22 RCS DRAINDOWN - TOP OF RVHSS 830726 007057 D410001 PRE HEAD LIFT EXAM 2 UM 0.255 3.87 SECURE SPREADER RING / SECURE PENDANT -!!F
  • 830726 007057 D41D001 PRE HEAD LIFT EXAM 2 MM 0.274 4.45 SECURE SPREADER RING / SECURE FENDANT -IIF 830729 007080 D22E001 NEUTRON SHIELD TANKS 4 CN 0.513 7.81 CUT NEUT SHIELD TKS-SHALLOW END OF CANAL

$830729 007080 D22E001 NEUTRON SHIELD TANKS 1 EL 0.082 1.52 CUT NEUT SHIELD TKS-SHALLOW END OF CANAL 830729 007078 D22E010 RCS WATER LEV. CNTRL 2 OP 0.452 3.22 RCS DRAINDOWN - RVHSS & 'A' D-RING

  • 830729 007078 022E010 RCS WATER LEV. CNTRL 1 RP 0.091 2.03 RCS DRAINDOWN - RVHSS &

'A' D-RING

  • 830729 007078 D22E010 RCS WATER LEV. CNTRL 2 HP 0.535 3.15 RCS DRAINDOWN - RVHSS &

'A' D-RING 830729 007091 D22E010 RCS WATER LEV. CNTRL 2 IC 0.026 6.45 SWITCH SENSING LINE/ CALIBRATE RC-LT-100 830729 007089 D22E021 SDS MODIFICATIONS 1 ES 0.008 4.62 LEAKRATE & HYDRO TEST SUMP SUCKER LINE

  • 830729 007089 D22E021 SDS MODIFICATIONS 8 CN 0.019 15.65 LEAKRATE & HYDRO TEST SUMP SUCKER LINE

$830729 007089 D22E021 SDS MODIFICATIONS 1 QA 0.005 3.15 LEAKRATE & HYDRO TEST SUMP SUCKER LINE 830801 007092 D22E001 NEUTRON SHIELD TANKS 11 CN 1.110 17.33 RIG AND CUT NEUTRON SHIELD TANKS

  • 830801 007092 D22E001 NEUTRON SHIELD TANKS 1 EL 0,079 1.65 RIG AND CUT NEUTRON SHIELD TANKS 830801 007095 D22E010 RCS WATER LEY. CNTRL 1 OP 0.091 0.73 RCS DRAINDOWN - TOP OF CORE FLOOD TK

'A'

  • 830801 007095 D22E010 RCS WATER LEV. CNTRL 1 HP 0.138.

0.75 RCS DRAINDOWN - TOP OF CORE FLOOD TK 'A' INTERNALS INDEX FIXT 1 HP 0.000 1.25 INSPECT 3 LIFTING PENDANTS FOR IIF $$ *830803 007121 D22E019 830803 007121 D22E019 INTERNALS INDEX FIXT 1 QA 0.000 0.73 INSPECT 3 LIFTING PENDANTS FOR IIF e

  • 830803 007121 D22E019 INTERNALS INDEX FIXT 1 MD 0.000 1.05 INSPECT 3 LIFTING PENDANTS FOR IIF 830805 007131 D22E010 RCS WATER LEV. CNTRL 2 UM 0.151 3.62 REMOVE TEMP CLOSURES FROM CRDM/INSTL CAP 830807 007151 D20E001 RD&D SUPP-0UTS CTMT 4 IC 0.000 5.93 MARK CABLE AM7 TEST 83C808 007145 D22E001 NEUTRON SHIELD TANKS 14 CN 1.210 22.75 CUT AND REM 0vE NEUTRON SHIELD TANKS

$830808 007145 D22E001 NEUTRON SHIELD TANKS 2 EL 0.198 3.70 CUT AND REMOVE NEUTRON SHIELD TANKS 830809 007168 D22E013 SERVICE AIR 1 OP 0.068 1.20 FAB MANIFOLD / INSTALL BULLARD FILTER

  • 330809 007168 D22E013 SERVICE AIR 2 IC 0.131 2 60 FAB MANIFOLD / INSTALL BULLARD FILTER 3830809 007168 D22E013 SERVICE AIR 1 UM 0.048 1.30 FAB MANIFOLD / INSTALL BULLARD FILTER 830810 007179 D22E019 INTERNALS INDEX FIXT 1 RW 0.002 0.53 INSPECT IIF PENDANT ASSEMBLY
  • 830810 007179 022E019 INTERNALS INDEX FIXT 1 CN 0.005 0.52 INSPECT IIF PENDANT ASSEMBLY 830811 007181 D22E009 UNDERHEAD DATA ACQUI 1 CM 0.082 1.45 INSTALL MANIPULATOR SUPPORT TUBE-RVHSS
  • 830811 007181 D22E009 UNDERHEAD DATA ACQUI 1 OP 0.058 1.25 INSTALL MANIPULATOR SUPPORT TUBE-RVHSS

$830811 007181 022E009 UNDERHEAD DATA ACQUI 2 MM 0.113 2.30 INSTALL MANIPULATOR SUPPORT TUBE-RVHSS 830811 007182 D22E013 SERVICE AIR 2 CN 0.448 4.10 CONTAINMENT SERVICE AIR TEST

  • 830811 007182 D22E013 SERVICE AIR 1 OP 0.226 2.03 CONTAINMENT SERVICE AIR TEST 830811 007183 D410001 PRE HEAD LIFT EXAM 1 CN 0.106 1.65 INSPECT IIF PENDANT SUPPORTS 830812 007212 D20E001 RD&D SUPP-0UTS CTMT 1 HP 0.000 1.67 DECON CAMERAS AND TRANSFER TO HOT SH3P

$830812 007212 D20E001 RD&D SUPP-0UTS CTMT 3 IC 0.000 8.38 DECON CAMERAS AND TRANSFER TO NOT SH3P

  • 830812 007212 D20E001 RD&D SUPP-0UTS CTMT 1 RP 0.000 1.10 DECON CAMERAS AND TRANSFER TO HOT SH3P 830812 007199 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.158 3.62 UNDERHEAD CHARACTERIZATION - VIDEO INSP

$830812 007199 D22E009 t*DERHEAD DATA ACQUI 2 IC 0.102 2.40 UNDERHEAD CHARACTERIZATION - VIDEO IMOP

  • 830812 007199 D22E009 DERHEAD DATA ACQUI 1 RP 0.141 3.78 UNDERHEAD CHARACTERIZATION - VIDEO IN5F 3830812 007199 022E009 U'NDERHEAD DATA ACQUI 2 CN 0.264 7.18 UNDERHEAD CHARACTERIZATION - VIDEO INSP B30812 007:00 D22E013 SERVICE AIR 2 CN 0.192 2.53 REPLACE SERVICE AIR QUICK DISCONNECT 830815 007239 D20E001 RD&D SUPP-0UTS CTMT 2 IC 0.000 2.98 DATA ACQUISITION-WEST TV CAMERA 830815 007215 022E001 NEUTRON SHIELD TANKS 1 MM 0.089 1.73 REMOVE NEUTRON SHIELD TANKS

DATE 022186 PAGE 10 PNO. 9 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP.

  • .D. ATE... NUM8. E R...,.....E.R....

....... C. T. I V I T. Y.................. E. N T R G. C. OD E....... E. M....... U. R S...,.......,............. T A S. K D. E. S. C. R I. P T I O N NUMB A R HO

  • 830815 007215 D22E001 NEUTRON SHIELD TANKS 3 CN 0.356 5.15 REMOVE NEUTRON SHIELD TAWKS 830815 007218 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.130 3.48 UNDERHEAD CHARACTERIZATION 8830815 007218 D22E009 UNDERHEAD DATA ACQUI 1 RP 0.171 3.63 UNDERHEAD CHARACVERI2ATION
  • 830815 007218 D22E009 UNDERHEAD DATA ACQUI 2 CN 0.222 5,38 UNDERHEAD CHARACTERIZATION 830816 007241 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.159 3.92 UNDERHEAD CHARACTERIZATION /RV RAD MEAS
  • 830816 007241 D22E009 UNDERHEAD DATA ACQUI 2 RP 0.258 5.42 UNDERHEAD CHARACTERIZATION /RV RAD MEAS 3830816 007241 022E009 UNDERHEAD DATA ACQUI 3 CN 0.357 9.30 UNDERHEAD CHARACTERIZATION /RV RAD MEAS 830816 007243 D22E013 SERVICE AIR 2 CN 0.460 3.70 CONTAINMENT SERVICE AIR TEST
  • 830816 007243 D22E013 SERVICE AIR 1 OP 0.248 1,77 CONTAINMENT SERVICE AIR TEST 830816 007246 D41D001 PRE HEAD LIFT EXAM 2 RP 0.000 4.82 TRANSPORT PLENUM SAMPLES
  • 830816 007246 D410001 PRE HEAD LIFT EXAM 1 HP 0.000 2.58 TRANSPORT PLENUM SAMPLES
  • 830816 007246 D410001 PRE HEAD LIFT EXAM 1 EL 0.000 2.37 TRANSPORT PLENUM SAMPLES
  • 830816 007246 D41D001 PRE HEAD LIFT EXAM 1 CM 0.005 2.23 TRANSPORT PLENUM SAMPLES 830818 007257 020E001 RD&D SUPP-0UTS CTMT 2 CN 0.006 13.53 ASSESM8LE URANIUM FOILS 830819 007262 D22E002 RX HEAD INSULATION 1 EL 0.112 1.53 CUT MIRROR INSULATION
  • 830819 007262 D22E002 RX HEAD INSULATION 4 CN 0.429 6.12 CUT MIRROR INSULATION 830819 007265 D22E004 CANAL SEAL PLATE I CN 0.050 0.65 INSPECT' SEAL LEDGE FOR CLEANING REQMTS 830819 007266 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.200 1.50 PLACE SSTR NEUT DOSIM-HOT LEG PIPING
  • 830819 007266 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.455 2.73 PLACE SSTR NEUT DOSIM-HOT LEG PIPING
  • 830819 007266 D22E009 UNDERHEAD DATA ACQUI 1 MM 0.203 1.38 PLACE SSTR NEUT 00SIM-HOT LEG PIPING 830819 007272 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.000 6.10 DATA ACO SUPP/ INSTALL TV CAME RA& CHECK OP e

830822 007275 D41D001 PRE HEAD LIFT EXAM 1 HP O.145 3.73 UNDERHEAD RAD CHARACTERIZATION b) 830822 007275 D41D001 PRE HEAD LIFT EXAM 1 RP 0.117 2.95 UNDERHEAD RAD CHARACTERIZATION Um *830822 007275 D410001 PRE HEAD LIFT EXAM 2 CN 0.249 6.72 UNDERHEAD RAD CHARACTERIZATION 8 830823 007303 D22E002 RX HEAD INSULATION 1 MM 0.154 2.33 CUT MIRROR INSULATION

  • 830823 007303 D22E002 RX HEAD INSULATION 4 CN 0.597 8.97 CUT MIRROR INSULATION 830823 007306 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.006 10.85 DECON TV CAMERA FOR RCDT 830823 007309 D22E009 UNDERHEAD DATA ACQUI 3 IC 0.001 7.68 REBAG DATA ACQUISITION TV CABLE 830823 007302 D41C005 ELECTRICAL SUPPORT 2 IC 0.081 1.92 INSTALL COAX CABLE FROM RVHSS TO CCT-18 830824 C07315 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.000 0.88 DECON TV CAMERA 830826 C07319 D22E002 RX HEAD INSULATION 3 CN 0.556 5.73 CUT MIRROR INSULATION 830826 007321 D22E004 CANAL SEAL PLATE 7 CN 0.955 13.96 RIG SEAL PLATE TO 322'/ PREP FOR DRILLING

$830826 007321 022E004 CANAL SEAL PLATE 1 EL 0.126 2.12 RIG SEAL PLATE TO 322'/ PREP FOR DRILLING 830826 007323 D22E004 CANAL SEAL PLATE 1 RW 0.202 1.85 PREPARE AND CLEAN SEAL PLATE $830826 007323 D22E004 CANAL SEAL PLATE 1 UM 0.141 1.93 PREPARE AND CLEAN SEAL PLATE 830826 007324 D22E004 CANAL SEAL PLATE 1 RP O.064 1.23 PREPARE SEAL PLATE LAY-DOWN AREA

  • 830826 007324 D22E004 CANAL SEAL PLATE 1 OP 0.079 1.30 PREPARE SEAL PLA1E LAY-DOWN AREA 830826 007318 D22E023

~'D*' RING CATWALK 2 CN 0.030 0.77 INSTALL HANDRAIL - TOP OF 'B' D-RING 830829 007350 D22E009 UNDERHEAD DATA ACQUI 1 EL 0.082 1.77 CORE TOPOGRAPHY DATA ACQ TOUL STAGING

  • 830829 007350 D22E009 UNDERHEAD DATA ACQUI 4 IC 0.429 6.90 CORE TOPOGRAPHY DATA ACQ TOOL STAGING
  • 830829 007350 D22E009 UNDERHEAD DATA ACQUI 4 CN 0.359 7.27 CORE TOPOGRAPHY DATA ACQ TOOL STAGING 830901 007377 D20F001 FUEL CANAL MODS.

2 CN 0.4A3 4.27 VIDEO SURVEY OF VALVE SF-V-104 830902 007379 D22E002 RX HEAD INSULATION 4 CN 0.774 10.25 CUT MIRROR INSULATION 830906 007396 022E002 RX HEAD INSULATION 8 CN 1.253 15.80 CUT MIRROR INSULATION 830906 007392 D22E009 UNDERHEAD DATA ACQUI 1 EL 0.187 2.27 REMOVE TOPOG DATA ACO TOOLS AND EQUIP.

  • 830906 007392 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.295 4.12 REMOVE TOPOG DATA ACQ TOOLS AND EQUIP.

3830906 007392 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.108 2.65 REMOVE TOP 0G DATA ACQ TOOLS AND EQUIP. 3830906 007392 D22E009 UNDERHEAD DATA ACQUI 2 CN 0.305 4.13 REMOVE TOPOG DATA ACO TOOLS AND EQUIP. 830906 007393 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.068 1.48 UNDERHEAD RADIATION MEASUREMENT

  • 830906 007393 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.047 1.47 UNDERHEAD RADIATION MEASUREMENT

DATE 022186 PAGE 11 PNO. 10 .TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. .........................IPTION TASK DESCR NUMBER, ACTIVITY ENTRG. CODE REM HOURS.

  • DATE s.......

NUMBER. 830907 007417 D22E014 TEMPORARY POWER 2 CN 0.185 2.70 CLEAN CABLES AT POWER BUGGY 830908 007424 D22E002 RX HEAD INSULATION 2 CN 0.174 2.50 CUT AND RIG MIRROR INSULATION 830908 007425 D22E009 UNDERHEAD DATA ACQUI 4 HP 0.418 9.38 CORE DEBRIS GRAB SAMPLE EQUIP STAGING 2830908 007425 D22E009 UNDERHEAD DATA ACQUI 2 EL 0.213 3.45 CORE DEBRIS GRAB SAMPLE EQUIP STAGING

  • 830908 007425 D22E009 UNDERHEAD DATA ACQUI 4 IC 0.395 7.00 CORE DEBRIS GRAB SAMPLE EQUIP STAGING
  • 830908 007425 D22E009 UNDERHEAD DATA ACQUI 9 CN 0.885 19.70 CORE DEBRIS GRAB SAMPLE EQUIP STAGING 830909 0C7435 D22E009 UNDERHEAD DATA ACQUI 1 OP 0.075 0.92 SSTR DOSIM RETRIEVAL-SHALLOW END OF POOL
  • 830909 007435 D22E009 UNDERHEAD DATA ACQUI 1 MM 0.184 0.73 SSTR DOSIM RETRIEVAL-SHALLOW END OF POOL
  • 830909 007435 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.055 0.65 SSTR DOSIM RETRIEVAL-SHALLOW END OF P30L 830909 007443 D22E009 UNDERHEAD DATA ACQUI 1 ES 0.002 3.28 UNLOAD SSTR'S - HOT I&C SHOP
  • 830909 007443 D22E009 UNDERHEAD DATA ACQUI 2 CN 0.004 6.47 UNLOAD SSTR'S - HOT I&C SHOP 830912 007450 D22E002 RX HEAD INSULATION 1 MM 0.107 1.92 RIG MIRROR INSULATION-347' TO 305' ELEV
  • 830912 007450 D22E002 RX HEAD INSULATION 2 EL 0.197 3.67 RIG MIRROR INSULATION-347' TO 305" ELEV 833912 007452 041C017 LDSCR-UNCOUPLE & PARK 1 EL 0.088 1.70 INSTALL HOIST UNDER MISSILE SHIELDS
  • 830912 007452 D41C017 LDSCR-UNC00PLE& PARK 4 CN 0.388 6.78 INSTALL HOIST UNDER MISSILE SHIELDS 830913 007475 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.344 3.25 INSTALL NUC INSTRUMENTATION COVER PLATES
  • 830913 007475 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.151 2.35 INSTALL NUC INSTRUMENTATION COVER PLATES 830914 007482 D22E009 UNDERHEAD DATA ACQUI 1 EL 0.071 1.28 TRIAL FIT CANAL SEAL PLATE 2830914 007482 D22E009 UNDERHEAD DATA ACQUI 6 CN 0.565 9.99 TRIAL FIT CANAL SEAL PLATE 830919 007499 D22E002 RX HEAD INSULATION 2 OP 0.092 1.77 SET UP CUTTING AREA / CLEAN BANDSAW AREA
  • 830919 007499 D22E002 RX HEAD INSULATIDN 2 IC 0.127 1.82 SET UP CUTTING AREA / CLEAN BANDSAW AREA 830920 007%29 D20E001 RD&D SUPP-0UTS CTMT 1 CM 0.000 0.08 MOVE PENDANT TO FHB 305/ REPAIR COMPACTCR I *830920 007529 D20E001 RD&D SUPP-0UTS CTMT 5 CN 0.002 6.20 MOVE PENDANT TO FHB 305/ REPAIR COMPACTOR b3 830920 007523 D22E002 RX HEAD INSULATION 1 MM 0.160 2.72 CUT MIRROR INSULATION RACKS WITH BANDSAW CN 8830920 007523 D22E002 RX HEAD INSULATION 13 CN 1.303 22.50 CUT MIRROR INSULATION RACKS WITH BANDSAW 8

831003 007674 D22E009 UNDERHEAD DATA ACQUI 4 HP 0.459 10.72 CORE DEBRIS GRAB SAMPLE

  • 831003 007674 D22E009 UNDERHEAD DATA ACQUI 6 CN 0.627 16.40 CORE DEBRIS GRAB SAMPLE 831010 007728 D22E009 UNDERHEAD DATA ACQUI 2 OP 0.254 4.10 CORE DEBRIS SAMPLING EQUIPMENT DESTAGING
  • 831010 007728 022E009 UNDERHEAD DATA ACQUI 1 MM 0.101 1.30 CORE DEBRIS SAMPLING EQUIPMENT DESTAGING
  • 831010 007728 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.147 1.97 CORE DEBRIS SAMPLING EQUIPMENT DESTAGING 831010 007731 D41C017 LDSCR-UNCOUPLE & PARK 2 MM 0.142 3.55 INSTALL HOIST UNDER MISSILE SHIELDS
  • 831010 007731 041C017 LDSCR-UNCOUPLE & PARK 14 CN 1.093 19.78 INSTALL HOIST UNDER MISSILE SHIELDS 831012 007748 D41C017 LDSCR-UNCOUPLE & PARK 2 OP 0.170 4.00 TRIAL PARK 5 LEADSCREWS
  • 831012 007748 D41C017 LDSCR-UNCOUPLE & PARK 2 HP 0.208 4.53 TRIAL PARK 5 LEADSCREWS
  • S31012 007748 D41C017 LDSCR-UNCOUPLE & PARK 3 CN 0.248 5.95 TRIAL PARK 5 LEADSCREWS 831018 007787 D41C005 ELECTRICAL SUPPORT 4 CN 0.503 7.18 INSTALL REFUELING CANAL LIGHTING
  • 831018 007787 D41C005 ELECTRICAL SUPPORT 1 RP 0.033 1.10 INSTALL REFUELING CANAL LIGHTING 831018 007792 D41C017 LDSCR-UNCOUPLE & PARK 1 OP 0.102 2.77 UNPARK LEADSCREWS
  • 831018 007792 D41C017 LDSCR-UNCOUPLE & PARK 1 HP 0.129 2.98 UNPARK LEADSCREWS
  • 831018 007792 D41C017 LDSCR-UNCOUPLE & PARK 1 CN 0.130 3.00 UNPARK LEADSCREWS 831212 008074 D22E013 SERVICE AIR 2 CN 0.286 3.62 STANDARDIZE SERVICE AIR CONNECTIONS 831219 008117 D22E002 RX HEAD INSULATION 1 MM 0.094 1.58 CUT MIRROR INSUL RACK BASE-PLASMA ARC
  • 831219 008117 D22E002 RX HEAD INSULATION 4 CN 0.325 6.64 CUT MIRROR INSUL RACK BASE-PLASMA ARC 831219 008121 D22E024 SPOOL PIECE REMOVAL 2 CN 0.308 5.67 STATOR COOLING WATER PIPING REMOVAL 840109 008220 D22E019 INTERNALS INDEX FIXT 2 QA 0.316 5.15 NDE TRIPOD WELDS / INSPECT TURNBUCKLES
  • 840109 008220 D22E019 INTERNALS INDEX FIXT 2 CN 0.236 3.78 NDE TRIPOD WELDS / INSPECT TURNBUCKLES 840109 008226 D45J004 P.C.

LOAD TEST 4 CN 0.654 10.28 MARK MISSILE SHIELDS AND LOAD FRAME 840116 008269 D20F001 FUEL CANAL MODS. 3 CN 0.381 11.23 TEST SF-V-102 & CUT REFUELING CANAL PIPE 840116 008267 D22E004 CANAL SEAL PLATE 1 QA 0.100 1.37 INSPECT / MEASURE CANAL SEAL PLATE

  • 840116 008267 D22E004 CANAL SEAL PLATE 1 CN 0.240 3.72 INSPECT / MEASURE CANAL SEAL PLATE

DATE 022186 PAGE 12 PNO. 11 .TMI-2 UNC: DOS - ACTIVITY REPORT - REACTLR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. .............. T. A S. K.D. E. S. C. R. I P T I O N............

  • D. A T E... NUMB E.R...... B. E. R.........C. T. I V I T.

Y................. E. N. T R G. C. O. D. E.......E.M NUM A R ..HOU.R S.......... 840116 008268 D22E004 . CANAL SEAL PLATE 6 CN 1.236 18.65 TRIAL FIT CANAL SEAL PLATE 840116 008262 022E006 AUX FH BRIDGE 3 CN 0.437 6.95 INSP AFH BRIDGE ELEC/P.C. POWER PROT BOOT 840116 008270 D45J002 P.C. MECHANICAL 1 EL 0.230 3.48 INSTALL POLAR CRANE MARKERS

  • 840116 008270 D45J002 P.C.

MECHANICAL 2 CN 0.394 7.78 INSTALL POLAR CRANE MARKERS 840119 008294 D22E009 UNDERHEAD DATA ACQUI 1 RP 0.000 0.47 MOVE PLENUM SAMPLE TO PNL TRAILER 840123 008311 D20F001 FUEL CANAL MODS. 4 CN 0.375 8.52 CUT INSUL RACK BASES WITH PLASMA ARC 840123 008305 D22E004 CANAL SEAL PLATE 2 IC 0.132 2.73 REMOVE NI COVER PLATE GASKETS 840123 008312 D22E004 CANAL SEAL PLATE 1 QA 0.100 1.95 INSPECT / MEASURE CANAL SEAL PLATE

  • 840123 008312 D22E004 CANAL SEAL PLATE 1 CN 0.150 3.73 INSPECT / MEASURE CANAL SEAL PLATE 840123 008313 D22E004 CANAL SEAL PLATE 6 CN 0.798 14.00 TRI AL FIT CANAL SE AL PLATE
  • 840123 008313 D22E004 CANAL SEAL PLATE 1 MM 0.083 1.52 TRIAL FIT CANAL SEAL PLATE 840123 008314 D45J002 P.C.

MECHANICAL 1 QA 0.075 1.58 REPLACE FILLER PLATES FOR RAIL CLAMPS 2840123 008314 D45J002 P.C. MECHANICAL 1 EL 0.126 1.58 REPLACE FILLER PLATES FOR RAIL CLAMPS

  • 840123 008314 D45J002 P.C. MECHANICAL 2 CN 0.150 3.77 REPLACE FILLER PLATES FOR RAIL CLAMPS 840130 008351 D22E006 AUX FH BRIDGE 3 CN 0.298 4.13 AFH BRIDGE ELECTRICAL INSPECTION 840130 008353 D22E006 AUX FH BRIDGE 2 CN 0.260 3.22 AFH BRIDGE MECHANICAL INSPECTION 840201 008375 D22E002 RX HEAD INSULATION 3 CN 0.320 6.37 CUT MIRROR INSULATION RACK BASES 840201008377 D22E030 REMOVE HEAD 5 CN 1.373 17.33 INSTALL EQUALIZER BRACKETS ON LOAD FRAME

$840201 008377 D22E030 REMOVE HEAD 1 EL 0.225 3.45 INSTALL EQUALIZER ERACKETS ON LOAD FRAME 840201 008376 D45J001 P.C. INSPECTIONS 3 EL 0.346 5.87 DEFEAT TROLLEY LIMIT SWITCHES

  • 840201 008376 Dd5J001 P.C.

INSPECTIONS 3 CN 0.447 6.65 DEFEAT TROLLEY LIMIT SWITCHES e 840206 008402 D20F00; FUEL CANAL MODS. 3 CN 0.493 9.70 CUT INSUL RACK BASES / REPLACE BOTTLES h3 *840206 008402 D20F001 FUEL CANAL MODS. 1 EL 0.150 3.00 CUT INSUL RACK BASES / REPLACE BOTTLES ~4 840206 008401 D22E030 REMOVE HEAD 5 CN 0.420 7.78 INSTALL EQUALIZER BRACKETS 8 *840206 008401 D22E030 REMOVE HEAD 1 EL 0.089 1.52 INSTALL EQUALIZER BRACKETS 840206 008394 0453001 P.C. INSPECTIONS 2 CN 0.200 3.60 CONDUCTOR BAR INSPECTION 840206 008395 D45J004 P.C. LOAD TEST 1 EL 0.127 1.70 COMPLETE NO-LOAD TEST

  • 840206 008395 D45J004 P.C.

LOAD TEST 2 CN 0.147 3.78 COMPLETE NO-LOAD TEST

  • 840206 C08395 D45J004 P.C.

LOAD TEST 1 QA 0.063 1.33 COMPLETE NO-LOAD TEST 840206 C08397 045J004 P.C. LOAD TEST 4 CN 0.208 4.18 REPLACE LUG BOLTS ON P.C. LIFT FRAME 840208 C08420 D20F001 FUEL CANAL MODS. 3 CN 0.095 2.22 INSTALL POWER FOR CANAL DRAIN PUMP 840208 008419 D22E007 SERVICE STRUCT HOIST 7 CN 0.920 13.55 REMOVE MISSILE SHIELD HOIST A FRAME

  • 840208 008419 D22E007 SERVICE STRUCT HOIST 1 MM 0.116 1,98 REMOVE MISSILE SHIELD HOIST A FRAME 840208 008421 D45J004 P.C.

LOAD TEST 7 CN 0.811 14.80 STAGE RIGGING FOR LOAD TEST

  • 840208 008421 045J004 P.C.

LOAD TEST 2 MM 0.229 3.85 STAGE RIGGING FOR LOAD TEST 840210 008431 D20F001 FUEL CANAL MODS 2 CN 0.065 2.20 INSTALL POWER FOR CANAL DRAIN PUMP 840210 008427 D22E003 RV STUD REMOVAL 4 CN 0.671 9.60 STAGE STUD CLEANING TOOLS

  • S40210 008427 D22E003 RV STUD REMOVAL 1 MM 0.155 2.57 STAGE STUD CLEANING TOOLS 840210 008429 D45J003 P.C. ELECTRICAL 2 EL 0.267 3.42 REPLACE MR DELAY / DEFEAT LIMIT SWITCHES 840210 008428 D45J004 P.C.

LOAD TEST 1 EL 0.090 1.95 REMOVE 5 TON HOIST AND MAN BASKET

  • 840210 008428 D45J004 P.C.

LOAD TEST 4 CN 0.408 7.55 REMOVE 5 TON HOIST AND MAN BASKET 840213 008452 D45J003 P. C. E L EC T R ICAL 1 EL 0.085 1.07 REPLACE COIL ON MAIN CONDUCTOR

  • 840213 008452 045J003 P.C. ELECTRICAL 1 CN 0.070 1,12 REPLACE COIL ON MAIN CONDUCTOR 840213 008440 045J004 P.C.

LOAD TEST 6 CN 0.810 10.08 POLAR CRANE LOAD ASSEMBLY

  • 840213 008440 D45J004 P.C.

LOAD TEST 4 MM 0.775 9.17 POLAR CRANE LOAD ASSEMBLY

  • 840213 008440 D45J004 P.C.

LOAD TEST 1 EL 0.140 1.95 POLAR CRANE LOAD ASSEMBLY

  • 840213 008440 D45J004 P C.

LOAD TEST 2 IC 0.240 2.13 POLAR CRANE LOAD ASSEMBLY 840215 C08463 D22E028 FILL PROVISION 14 CN 0.032 29.58 INSTALL HANGERS 840215 008467 D45J003 P.C. ELECTRICAL 2 EL 0.087 1.82 RESTORE TROLLEY LIMIT SWITCH 840215 008465 D45J004 P.C. LOAD TEST 11 CN 1.859 29.74 POLAR CRANE LOAD TEST ACTIVITIES

m. m.____m .... _ _ _. _ _ _ _ _ ~ _ _ - _ _ I DATE 022186 PAGE 13 PNO. 12 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 0 PERS. DEPT. EXPOS. RWP. TAS . RWP .EXP-TRCK. ....... ENTRG. CODE..................................................K. DESCRIPTION REM. HOURS.

  • ...............................IVIT.Y..........
  • DATE, NUMBER. NUMBER,

ACT a 2

  • 840215 008465 D45J004 P.C.

LOAD TEST 2 MM 0.334 5.58 . POLAR CRANE LOAD TEST ACTIVITIES j

  • 840215 008465 D45J004 P.C.

LOAD TEST 2 QA 0.450 6.28 POLAR CRANE LOAD TEST ACTIVITIES 4 840217 008479 D20A001 RX DISASSEMBLY PREP 2 CN 0.245 3.25 CONTAINMENT INSPECTION 840217 008480 D45J002 P.C. MECHANICAL 5 CN 0.413 7.47 REPLACE BOLTS IN UPPER SPREADER PLATE 840217 008481 D45J004 P.C LOAD TEST 5 CN 1.069 16.47 POLAR CRANE LOAD TEST

  • 840217 008481 D45J004 P.C.

LOAD TEST 1 EL 0.203 3.23 POLAR CRANE LOAD TEST

  • 840217 008481 045J004 P.C LOAD TEST 1 QA 0.200 3.10 POLAR CRANE LOAD TEST 840221 008506 D22E028 FILL PROVISION 6 CN 0.004 15.17 INSTALL PIPE HANGERS 840227 008528 D35E001 SHIELD RVHSS 3 CN 0.408 5.12 REMOVE RVHSS SHIELDING SUPPORT i

840228 008541 D45J004 P.C. LOAD TEST 5 CN 1.065 17.07 POLAR CRANE LOAD TEST

  • 840228 008541 D45J004 P.C.

LOAD TEST 1 EL 0.250 3.97 POLAR CRANE LOAD TEST

  • 840228 008541 D45J004 P.C.

LOAD TEST 2 IC 0.150 2.23 POLAR CRANE LOAD TEST 840229 008545 D45J004 P.C. LOAD TEST 11 CN 2.694 37.04 POLAR CRANE LOAD TEST

  • 840229 008545 D45J004 P.C.

LOAD TEST 2 QA 0.430 5.93 POLAR CRANE LOAD TEST

  • 840229 008545 045J004 P.C.

LOAD TEST 2 EL 0.442 7,87 POLAR CRANE LOAD TEST I

  • 840229 008545 045J004 P.C.

LOAD TEST 4 MM 0.903 15.77 POLAR CRANE LOAD TEST 840302 008551 D22E006 AUX FH BRIDGE 3 CN 0.450 5.48 LUBE WHEELS-AFH BRIDGE 840302 008549 D45J004 P.C. LOAD TEST 4 CN 0.763 10.25 INSTALL PLATFORM ON SPREADER FRAME 4 840302 008552 D45J004 P.C. LOAD TEST 2 CN 0.330 4.42 DISASSEMBLE LOAD TEST ASSEMBLY 840305 008572 D22E008 MISSILE SHIELDS 4 CN 0.217 4.70 CUT HAND RAILS a 840305 008558 D45J002 P.C. MECHANICAL 4 CN 0.695 10.53 GEAR BOX OIL SAMPLES I e 840305 008559 D45J004 P.C. LOAD TEST 12 CN 3.061 46.63 DISASSEMBLE LOAD TEST FRAME / CLEAN HOOK 00 *840305 008559 D45J004 P.C. LOAD TEST 1 MM 0.260 4.42 DISASSEMBLE LOAD TEST FRAME / CLEAN HOOK PO

  • 840305 008559 045J004 P.C. LOAD TEST 1 EL 0.229 4.02 DISASSEMBLE LOAD TEST FRAME / CLEAN HOOK 340307 008580 D22E003 RV STUD REMOVAL 3 MM 0.844 8.70 CLEAN RX HEAD STUDS MECHANICALLY
  • 840307 008580 D22E003 RV STUD REMOVAL 1 EC 0.300 2.93 CLEAN RX HEAD STUDS MECHANICALLY
  • 840307 008580 D22E003 RV STUD REMOVAL 3 UM 0.890 8.62 CLEAN RX HEAD STUDS MECHANICALLY i
  • 840307 008580 D22E003 RV STUD REMOVAL 1 CN 0.300 3.32 CLEAN RX HEAD STUDS MECHANICALLY
  • 840307 008580 D22E003 RV STUD REMOVAL 1 MD 0.300 3.32 CLEAN RX HEAD STUDS MECHANICALLY 840307 008581 D22E019 INTERNALS INDEX FIXT 5 CN 0.600 8.52 STAGE VACUUMS / MEASURE IIF I

840307 008585 D45J003 P.C. ELECTRICAL 2 EL 0.328 6.93 TEST LOWER LIMIT SWITCH

  • 840307 008585 045J003 P.C. ELECTRICAL 1 UM 0.197 2.83 TEST LOWER LIMIT SWITCH i
  • 840307 008585 D45J003 P.C. ELECTRICAL 1 CN 0.120 3,43 TEST LOWER LIMIT SWITCH

~ 840307 008583 D45J004 P.C. LOAD TEST 1 EL 0.128 2.38 DISASSEMBLE LOAD TEST FRAME /NDE HOOK l

  • 840307 008583 D45J004 P.C.

LOAD TEST 4 CN 0.451 6.88 DISASSEMBLE LOAD TEST FRAME /NDE HOOK 3840307 008583 045J004 P.C. LOAD TEST 2 QA 0.101 1.32 DISASSEMBLE LOAD TEST FRAME /NDE HOOK 840308 008589 D22E003 RV STUD REMOVAL 3 MM 0.580 6.66 MECHANICAL CLEANING 0F HEAD STUDS

  • 840308 008589 D22E003 RV STUD REMOVAL 1 CN 0.250 2.32 MECHANICAL CLEANING OF HEAD STUDS 840308 008590 D45J004 P.C.

LOAD TEST 4 CN 0.739 9.95 REPLACE MAN BASKET &5 TON HOIST-MAIN P03K $340308 008590 D45J004 P.C. LOAD TEST-1 MM 0.165 2.70 REPLACE MAN BASKET &5 TON HOIST-MAIN HOOK 840312 008605 022E030 REMOVE HEAD 4 CN 0.445 8.40 CUT UP HEADLIFT SLINGS 1

  • 840312 008605 D22E030 REMOVE HEAD 1 MM 0.111 1.77 CUT UP HEADLIFT SLINGS l

840312 008602 D22E031 IST PASS-STUD DETENS 1 EL 0.177 3.08 RIG STUD TENSIONERS & NUT RUNNERS

  • 840312 008602 D22E031 IST PASS-STUD DETENS 6 CN 1.492 16.02 RIG STUD TENSIONERS & NUT RUNNERS I

840312 008603 D22E031 IST PASS-STUD DETENS 12 UM 2.988 27.57 DETENSIONING FIRST PASS-RV STUDS 840312 008603 D22E031 IST PASS-STUD DETENS 22 MM 6.026 56.90 DETENSIONING FIRST PASS-RV STUDS 840312 008"03 D22E031 IST PASS-STUD DETENS 4 OP 1.547 13.15 DETENSIONING FIRST PASS-RV STUDS t 840312 C08603 D22E031 IST PASS-STUD DETENS 2 MD 0.505 4.58 DETENSIONING FIRST PASS-RV STUDS 4' 840312 008603 D22E031 IST PASS-STUD DETENS 4 RP 1.058 10.90 DETENSIGNING FIRST PASS-RV STUDS 840312 008603 D22E031 IST PASS-STUD DETENS 2 CN 0.560 6.77 DETENSIONING FIRST PASS-RV STUDS 4 - - ~

DATE 022186 PAGE 14 PNO-13 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D

  • .D. ATE. RWP

.EXP-TRCK. PERS. DEPT EXPOS. RWP. . NUMBER...... B. E. R NUM AC .........T.IVITY................ENTRG...C. O. D E........M... RE ...OURS............................. S. K D. E SC R I. P T.I O N.............. H TA 340314 008630 D22E024 SPOOL PIECE REMOVAL 5 CN 1.020 13.39 REMOVE STATOR COOLING WATER PIPING 840314 008630 D22E024 SPOOL PIECE REMOVAL 1 MM 0.080 1.22 REMOVE STATOR COOLING WATER PIPING 840314 008630 D22E024 SPOOL PIECE REMOVAL 1 QA 0.150 2.22 REMOVE STATOR COOLING WATER PIPING 840314 008628 D45J001 P.C. INSPECTIONS 3 CN 0.389 6.37 INSTALL SAFETY LINES FOR MAN BASKET 840314 008627 D45J004 P.C. LOAD TEST 4 CN 0.688 12.00 INSPECT WIRE R0PE ON P.C. MAIN HOIST

  • 840314 008627 D45J004 P.C.

LOAD TEST 1 EL 0.130 2.60 INSPECT WIRE ROPE ON P.C MAIN HOIST 840316 008639 D22E006 AUX FH BRIDGE 4 CN 0.318 5.13 REMOVE MAST AND TROLLEY FROM AFH BRIDGE 840319 008647 D22E003 RV STUD REMOVAL 4 CN 0.587 8.69 MEASURE IIF BUSHING

  • 840319 008647 D22E003 RV STUD REMOVAL 1 EL 0.054 1.48 MEASURE IIF BUSHING 840321 008677 D20F001 FUEL CANAL MODS.

2 CN 0.140 2.27 ADDITIONAL LIGHTING - REFUELING CANAL 840321 008675 D22E009 UNDERHEAD DATA ACQUI 12 CN 1.484 32.47 CORE DEBRIS GRAB SAMPLE - PHASE 2

  • 840321 008675 D22E009 UNDERHEAD DATA ACQUI 2 EL 0.173 3.05 CORE DEBRIS GRAB SAMPLE - PHASE 2
  • 840321 008675 D22E009 UNDERHEAD DATA ACQUI 2 RP 0.407 8.33 CORE DEBRIS GRAB SAMPLE - PHASE 2
  • 840321 008675 022E009 UNDERHEAD DATA ACQUI 2 HP 0.351 8.23 CORE DEBRIS GRAB SAMPLE - PHASE 2 840321 008673 D22E010 RCS WATER LEV. CNTRL 1 CM 0.110 2.72 CRDM CLOSURE 2840321 008673 D22E010 RCS WATER LEV. CNTRL 1 MM 0.109 2.75 CROM CLOSURE
  • 340321 008673 D22E010 RCS WATER LEV. CNTRL 1 MD 0.090 2.72 CROM CLOSURE 840321 008676 022E031 IST PASS-STUD DETENS 1 MM 0.078 1.42 REMOVE STUD TENSIONERS FROM HOIST
  • 840321 008676 D22E031 IST PASS-STUD DETENS 3 CN 0.258 3.98 REMOVE STUD TENSIONERS FROM HOIST 840323 008689 D22E019 INTERNALS INDEX FIXT 2 QA 0.125 2.20 NDE TRIPOD WELDS 840324 008696 D22H001 FUEL REMOVAL 2 CN 0.243 4.85 PENETRATION INSPECTION-CORE FLOOD TANK A e 840328 008722 D20A001 RX DISASSEMBLY PREP 2 EL 0.122 3.08 ROUTINE POLAR CRANE OPERATIONS SUPPORT h3*840328 008722 D20A001 RX DISASSEMBLY PREP 1 MM 0.156 2.60 ROUTINE POLAR CRANE OPERATIONS SUPPORT M3 840328 008723 D22E009 UNDERHEAD DATA ACQUI I HP 0.130 3.25 CORE VIDEO MAPPING 8 *840328 008723 022E009 UNDERHEAD DATA ACQUI 7 CN 1.064 26 57 CORE VIDEO MAPPING
  • 840328 008723 D22E009 UNDERHEAD DATA ACQUI 4 RP 0.597 15.87 CORE VIDEO MAPPING 840329 008730 D45J002 P.C.

MECHANICAL 4 CN 0.425 6.28 MOVE RIGGING RACK TO 347' LEVEL 840330 008735 D22E012 CANAL ACCESS 2 CN 0.174 3.32 INSPECT SCAFFOLD TO REFUELING CANAL 840402 008742 D22E006 AUX FH BRIDGE 4 CN 0.531 7.78 AFH BRIDGE INSPECTION 840402 008743 D22E006 AUX FH BRIDGE 2 CN 0.299 3.07 AFH BRIDGE FEEDER CABLE DRYOUT 840402 008745 022E009 UNDERHEAD DATA ACQUI 1 HP 0.108 3.38 CORE VIDEO MAPPING 2840402 008745 022E009 UNDERHEAD DATA ACQUI 6 CN 0.825 20.45 CORE VIDEO MAPPING

  • 840402 008745 D22E009 UNDERHEAD DATA ACQUI 4 RP 0.430 12.70 CORE VIDEO MAPPING 840404 008762 D20A001 RX DISASSEMBLY PREP 1 MM 0.113 2.40 ROUTINE POLAR CRANE OPERATIONS 840404 008760 022E004 CANAL SEAL PLATE 1 OP 0.205 1.58 CLEAN CANAL SEAL LEDGE
  • 840404 008760 D22E004 CANAL SEAL PLATE 1 IC 0.190 1.53 CLE AN CANAL SE AL LEDGE

$840404 008760 D22E004 CANAL SEAL PLATE 1 CM 0.130 1.65 CLEAN CANAL SFAL LEDGE

  • 840404 008760 D22E004 CANAL SEAL PLATE 1 UM 0.243 1.53 CLEAN CANAL SEAL LEDGE

$840404 008760 D22E004 CANAL SEAL PLATE 1 MM 0.161 1.72 CLEAN CANAL SEAL LEDGE

  • 840404 008760 D22E004 CANAL SEAL PLATE 2 CN 0.206 3.15 CLEAN CANAL SEAL LEDGE 840404 008764 022E028 FILL PROVISION 2 HP 1.081 3.43 REMOVE RTD'S 840404 008764 022E028 FILL PROVISION 2 OP 0.310 2.32 REMOVE RTD*S 840404 008764 D22E028 FILL PROVISION 1 CN 0.240 1.25 REMOVE RTD*S 840406 008770 D22E004 CANAL SEAL PLATE 2 OP 0.175 3.45 CLEAN CANAL SEAL PLATE AND CANAL
  • 840406 008770 D22E004 CANAL SEAL PLATE 1 IC 0.079 1.75 CLEAN CANAL SEAL PLATE AND CANAL
  • 840406 008770 D22E004 CANAL SEAL PLATE 1 MM 0.113 1,72 CLEAN CANAL SEAL PLATE AND CANAL
  • 840406 008770 D22E004 CANAL SEAL PLATE 1 CN 0.100 1.68 CLEAN CANAL SEAL PLATE AND CANAL 840406 008769 D22E028 FILL FROVISION 1 HP 0.540 1.72 REMOVE RTD'S 840406 008769 022E028 FILL PROVISION 2 CN 0.566 2.97 REMOVE RTD*S 840406 008769 D22E028 FILL PROVISION 1 QA 0.159 1.20 REMOVE RTO'S

DATE 022186 PAGE 15 PNO. 14 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D RWP .EXP-TRCK. PERS, DEPT EXPOS. RWP.

  • DATE.. NUMBER. NUMBER ACT ENTRG CODE REM HOURS.

TASK DESCRIPTION ........................I.VITY .RX DISASSEMBLY PRE P 6 MM 0.773. 13.43. ROUTINE POLAR CRANE OPERATIONS 840409 008785 D20A001 $840409 008785 D20A001 RX DISASSEMBLY PREP 1 EL 0.115 2.18 ROUTINE POLAR CRANE OPERATIONS 840409 008783 D22E004 CANAL SEAL PLATE 6 CN 0.894 14.82 STAGE EQUIP FOR SEAL PLATE INSTALLATION 840409 008780 D22E005 CRDM REMOVAL 1 EL 0.491 9.93 REMOVE STATORS FROM RVHSS 3840409 038780 D22E005 CRDM REMOVAL 1 CN 0.135 2.62 REMOVE STATORS FROM RVHSS 840411 038804 D22E010 RCS WATER LEV. CNTRL 2 CM 0.147 2.75 CRDM CLOSURE

  • 840411 038804 D22E010 RCS WATER LEV. CNTRL 1 MM 0.074 1.30 CRDM CLOSURE
  • 840411 038804 022E010 RCS WATER LEV. CNTRL 1 MD 0.101 1.40 CROM CLOSURE 840412 008809 D22E004 CANAL SEAL PLATE 1 EL 0 200 1.93 CLEAN CANAL SEAL LEDGE AND CANAL

$840412 008809 022E004 CANAL SEAL PLATE 2 CH 0.357 4.85 CLEAN CANAL SEAL LEDGE AND CANAL

  • 840412 038809 022E004 CANAL SEAL PLATE 1 OP 0.218 2.38 CLEAN CANAL SEAL LEDGE AND CANAL
  • 840412 008809 D22E004 CANAL SEAL PLATE 1 CN 0.194 2.43 CLEAN CANAL SEAL LEDGE AND CANAL 840413 038815 D22E004 CANAL SEAL PLATE 1 QA 0.135 2.50 INSTALL SEAL PLATE GASKETS / CLEANING
  • 840413 038815 D22E004 CANAL SEAL PLATE 7 CN 1.398 17.87 INSTALL SEAL PLATE GASKETS / CLEANING 840413 008817 D22E006 AUX FH BRIDGE 2 CN 0.300 4.57 P.C.

PENDANT BOX AND CABLE DRYOUT 840413 038816 D22E010 RCS WATER LEV. CNTRL 2 OP 0.425 3.27 RCS FILL,& VENT /RCS LE AK INSPECTION 1840413 008816 D22E010 RCS WATER LEV. CNTRL 1 CN 0.170 2.33 RCS FILL & VENT /RCS LEAK INSPECTION 840416 008826 D20A001 RX DISASSEMBLY PREP 1 EL 0.090 1.75 ROUTINE POLAR CRANE OPERATIONS 840416 008525 D22E004 CANAL SEAL PLATE 24 CN 3.186 63.08 RIG SEAL PLATE INTO ANNULUS

  • 840416 008525 D22E004 CANAL SEAL PLATE 3 QA 0.260 5.35 RIG SEAL PLATE INTO ANNULUS 840417 008842 D22E004 CANAL SEAL PLATE 4 IC 0.360 6.70 REMOVE NI COVER PLATES 840419 008855 020A001 RX DISASSEMBLY PREP 1 MM 0.050 1.48 ROUTINE POLAR CRANE OPERATIONS 340419 008856 045J004 P.C.

LOAD TEST 3 CN 0.167 3.23 INSTALL LOAD RATING SIGNS ca C3 840423 008864 D20F001 FUEL CANAL MODS. 2 CN 0.196 2.62 AS-BUILT DIMENSION ON UP-ENDER TOOLS a 840423 008863 D22E004 CANAL SEAL PLATE 8 CN 0.821 18.08 FINAL SEAL PLATE CLEANUP /RTV SEAL 840425 008888 D20A001 RX DISASSEMBLY PREP 3 EL 0.391 7.50 ROUTINE POLAR CRANE OPERATIONS

  • 840425 008888 D20A001 RX DISASSEMBLY PREP 3 MM 0.405 7.53 ROUTINE POLAR CRANE OPERATIONS 840425 008890 D22E004 CANAL SEAL PLATE 4 CN 0.343 8.10 REMOVE AND CUT ANNULUS COVERS AND SUPPS.

840425 038889 022E006 AUX FH BRIDGE 4 CN 0.706 11.52 STAGE CATWALK FOR HEAD & TROLLEY REMOVAL 840425 008893 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.223 4.87 RELOCATE CAMERA 7/ INSTALL NEW CAMERA 840425 008894 022E012 CANAL ACCESS 1 QA 0.034 1.35 WELD INSPECTION-REFUEL CANAL LINER PLATE

  • 840425 008894 D22E012 CANAL ACCESS 1 CN 0.040 1.37 WELD INSPECTION-REFUEL CANAL LINER PLATE 840426 008897 D20F001 FUEL CANAL MODS.

8 CN 1.899 23.02 INSTALL CANAL SEAL PLATE PLATFORM 840426 008900 D22E006 AUX FH BRIDGE 8 CN 1.767 26.33 DISMANTLE AFH BRIDGE AND STAGE 840427 008903 D45J002 P.C. MECHANICAL 2 MM 0.466 5.20 RESET SNAP RING ON FLEX COUPLING

  • 840427 008303 045J002 P.C.

MECHANICAL 1 MD 0*.138 2.67 RESET SNAP RING ON FLEX COUPLING $840427 008903 D45J002 P.C. MECHANICAL 1 EL 0.171 2.47 RESET SNAP RING ON FLEX COUPLING 840430 008912 D20A001 RX DISASSEMBLY PREP 3 EL 0.397 7.28 ROUTINE POLAR CRANE OPERATIONS 840430 008911 D20F001 FUEL CANAL MODS. 6 CN 0.440 11.35 INSTALL CANAL SEAL PLATE PLATFORM 840430 008915 022E006 AUX FH BRIDGE 3 CN 0.457 7.4C DISMANTLE AFH BRIDGE 840502 008932 D22E006 AUX FH BRIDGE 4 CN 0,535 9.87 CUT UP MISCELLANEOUS PARTS 840502 008934 D22E006 AUX FH BRIDGE 2 CN 0.400 4.63 LUBE AFH BRIDGE 840502 008933 D45J001 P.C. INSPECTIONS 2 CN 0.325 4.30 INSPECT HEAD REMOVAL MARKERS 840503 008938 D22E008 MISSILE SHIELDS 3 CN 0.511 8.10 CUT UP MISSILE SHIELD PENDANT 840507 008950 D20A001 RX DISASSEMBLY PREP 3 EL 0.256 5.30 ROUTINE POLAR CRANE OPERATIONS 3840807 008950 D20A001 RX DISASSEMBLY PREP 2 MM 0.328 6.18 ROUTINE POLAR CRANE OPERATIONS 840507 008949 D22E006 AUX FH BRIDGE 18 CN 2,779 39.68 CUT UP AFH BRIDGE MASTS AND EQUIPMENT 840507 008947 D22E030 REMOVE HEAD 2 CN 0.617 4.43 HOIST POWER TO WALL MOUNTED JIS CRANE 840509 008970 D20A001 RX DISASSEMBLY PREP 6 UM 1.090 16.82 RESTAGE TOOLS IN CONTAINMENT 840509 008973 D20A001 RX DISASSEMBLY PREP 4 CN 0.955 17.68 REFURBISH WALL MOUNTED JIB CRANE

DATE 022186 PAGE 16 PNO 15 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP, ................ S. K D. E. S. C. R I P T. I O. N

  • D. ATE... NUMBE R.,...........E.RNUMB........... C. T. I.V I T. Y..................E.N T RG. C. O.D E.......E.M

.... U. R S.,........ A R HO TA RX DISASSEMBLY PREP 2 bM 0.273 2.38 MOVE CRDM H-8 TO POOL / MOVE RACK 340509 008974 D20A001

  • 840509 008974 020A001 RX DISASSEMBLY PREP 1 MM 0.140 2.67 MOVE CRDM H-8 TO POOL / MOVE RACK
  • 840509 008974 D20A001 RM DISASSEMBLY PREP 1 EL 0.117 5.18 MOVE CRDM H-8 TO POOL / MOVE RACK 840510 008983 D20E001 RD&O SUPP-0UTS CTMT 1 HP 0.000 5.12 NEUTRON ACTIVATION EXPERIMENT
  • 840510 008983 D20E001 RD&D SUPP-0UTS CTMT 1 OP 0.000 0.30 NEUTRON ACTIVATION EXPERIMENT
  • 840510 008983 020E001 RD&D SUPP-0UTS CTMT 1 CN 0.000 5.00 NEUTRON ACTIVATION E)PE RIMENT
  • 840510 008983 D20E001 RD&D SUPP-0UTS CTMT 1 EG 0.002 4.92 NEUTRON ACTIVATION EXPERIMENT 840511 008986 D22E030 REMOVE HEAD 2 CN 0.148 3.37 HOIST POWER TO WALL MOUNTED JIB CRANE 840514 008994 D20A001 RX DISASSEMBLY PREP 7 EL 0.842 15.58 ROUTINE POLAR CRANE OPERATIONS
  • 840514 008994 D20A001 RX DISASSEMBLY PREP 2 MM 0.210 3.70 ROUTINE POLAR CRANE OPERATIONS 840514 008995 D20A001 RX DISASSEMBLY PREP 3 CN 0.306 4.07 REFURBISH JIB CRANE 840514 008998 022E006 AUX FH BRIDGE 10 CN 1.319 21.02 LOWER AFH BRIDGE PARTS TO 347' LEVEL 840514 009011 022E030 REMOVE HEAD 2 CN 0.311 4.22 CUT HEADLIFT SLINGS 840515 009012 D20A001 RX DISASSEMBLY PREP 6 CN 0.504 7.77 MOVE STUD STORAGE RACK INTO REACTOR BLDG
  • 840515 009012 D20A001 RX DISASSEMBLY PREP 1 QA 0.067 0.97 MOVE STUD STORAGE RACK INTO REACTOR BLDG 840515 009010 D45J003 P C ELECTRICAL 9 CN 1.537 24.70 REMOVE BRIDGE CONDUCTOR BAR 840516 009019 D20A001 RX DISASSEMBLY PREP 2 UM 0.179 3.02 MOVE CABLE PLATFORM HANDRAIL
  • 840516 009019 D20A001 RX DISASSEMBLY PREP 1 MM 0.151 2.50 MOVE CABLE PLATFORM HANDRAIL
  • 840516 009019 D20A001 RX DISASSEMBLY PREP 1 EL 0.147 2,50 MOVE CABLE PLATFORM NANDRAIL 840516 009020 D20E001 RD&D SUPP-0UTS CTMT 1 HP 0.000 2.07 NEUTRON ACTIVATION EXPERIMENT a840516 009020 D20E001 RD&D SUPP-0UTS CTMT 1 EG 0.002 7.47 NEUTRON ACTIVATION EXPERIMENT e
  • 840516 009020 D20E001 RD&D SUPP-0UTS CTMT 2 CN 0.000 8.01 NEUTRON ACTIVATION EXPERIMENT 0J 840521 009034 D20A001 RX DTSASSEMBLY PREP 2 MM 0.154 3.78 ROUTINE POLAR CRANE OPERATIONS
  • 840521 009034 020A001 RX DISASSEMBLY PREP 4 EL 0.345 7.67 ROUTINE POLAR CRANE OPERATIONS 840521 009036 D22E006 AUX FH BRIDGE 1 CM 0.050 0.77 TRASH INSPECTION-305' LEVEL TO 367' LEVEL 2840521 009036 D22E006 AUX FH BRIDGE 1 RP 0.150 1.40 TRASH INSPECTION-305' LEVEL TO 367' LEVEL x840521 009036 022E006 AUX FH BRIDGE 1 IC 0.051 0.77 TRASH INSPECTION-305' LEVEL TO 367' LEVEL
  • 840521 009036 D22E006 AUX FH BRIDGE 1 CN 0.150 1.42 TRASH INSPECTION-305 ' LEVEL TO 367' LEVEL 840521 009037 D22E006 AUX FH BRIDGE 25 CN 3.361 48.87 DISASSEMBLE / CUT / REMOVE AFH TROLLEY 840521 009038 D45J003 P.C. ELECTRICAL 3 CN 0.252 4.40 REMOVE BRIDGE CONDUCTOR BAR 840523 009065 D22E012 CANAL ACCESS 4 CN 0.123 5.49 INSPECT LINER PLATE WELDS 840523 009063 D22E022 GUIDE STbOS 1 UM 0.099 2.33 TORQUE STUD RACK /RMVE 2 STUDS / FILL HOLES
  • 840523 009063 022E022 GUIDE STUDS 1 MM 0.095 2.77 TORQUE STUD RACK /RMVE 2 STUDS / FILL HOLES 840525 009071 022E006 AUX FH BRIDGE 4 CN 0.597 9.68 CLEAN / PREP / INSPECT PARTS ON AFH BRIDGE
  • 840525 009071 D22E006 AUX FH BRIDGE 1 QA 0.109 1.68 CLEAN / PREP / INSPECT PARTS ON AFH BRIDGE 840525 009072 D22E006 AUX FH BRIDGE 2 CN 0.178 2.03 DRAIN HYDRAULIC TANK-AFH BRIDGE 840530 009096 D20A001 RX DISASSEMBLY PREP 1 MM 0.132 2.73 ROUTINE POLAR CRANE OPERATIONS 840604 009120 D20A001 RX DISASSEMBLf PRE P 1 EL 0.091 1.72 ROUTINE POLAR CRANE OPERATIONS
  • 840604 009120 D20A001 RX DISASSEMBLY PREP 3 IC 0.256 5.65 ROUTINE POLAR CRANE OPERATIONS 840604 009132 D45J003 P.C. ELECTRICAL 2 CN 0.198 3.32 REPAIR 5 TON HOIST 840606 009143 D45J003 P.C. ELECTRICAL 2 CN 0.185 3.78 AEPAIR 5 TON HOIST 840607 009148 045J002 P.C. MECEANICAL 3 MM 0.561 6.33 POLAR CRANE SNAP RING - 427 & 440 840608 009156 D22E006 AUX FH BRIDGE 7 CN 1.230 14.58
  • INSTALL PLATFORM-AFH BRIDGE 840608 009158 D45J003 P.C. ELECTRICAL 5 CN 0.508 8.60

.EEDER REPLACEMENT 840611 009166 D20A001 RX DISASSEMBLY PREP 3 EL 0.183 3.90 ROUTINE POLAR CRANE OPERATIONS

  • 840611 009166 D20A001 RX DISASSEMBLY PREP 2 MM 0.171 2.90 ROUT INE POLAR CR ANE OPER ATIONS
  • 840611 009166 D20A001 RX DISASSEMBLY PREP 5 IC 0.422 8.23 ROUTINE POLAR CRANE OPERATIONS 840611 00;165 D22E006 AUX FH BRIDGE 29 CN 2.715 47.45 INSTALL PLATFORM-AFH BRIDGE
  • 840611 009165 D22E006 AUX FH BRIDGE 1 QA 0.072 1.48 INSTALL PLATFORM-AFH BRIDGE 840611 009167 D45J003 P.C. ELECTRICAL 7 CN 0.667 9.52 POWER FEEDER REPLACEMENT

DATE 022186 PAGE 17 PNO. 16 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 280 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. TASK DESCRIPTION

  • DATE NUMBER ACTIVITY

, ENTRG. CODE REM HOURS.

  • .......NUMBER....................................................................................................................

840612 009183 D22E012 CANAL ACCESS 8 CN 0.559 10.15 REMOVE REFUEL CANAL SCAFFOLD 840612 009185 D22E019 INTERNALS INDEX FIXT 4 CN 0.354 5.80 PREP AREA FOR IIF 840613 009196 D22E006 AUX FH BRIDGE 4 CN 0.397 6.23 REMOVE CABLE & CONDUIT-AFH BRIDGE 840613 009194 D45J003 P.C. ELECTRICAL 1 AD 0.090 1.58 PROVIDE EMERGENCY ACCESS TO POLAR CRANE

  • 840613 009194 D45J003 P.C. ELECTRICAL 1 AM 0.107 1.53 PROVIDE EMERGENCY ACCESS TO POLAR CRAhE 840613 009195 D45J003 P.C. ELECTRICAL

? EL 0.211 3.92 TROUBLESHOOT AND REPAIR POLAR CRANE '840613 009199 D45J003 P.C. ELECTRICAL 2 CN 0.251 3.87 REPAIR 5 TON HOIST PENDANT 840614 009200 045J004 P.C. LOAD TEST 4 CN 0.440 7.70 ASSEMBLE AFH BRIDGE PLATFORM 840615 009210 D20A001 RX DISASSEMBLY PREP 2 UM 0.070 1.43 INSTALL TEMPORARY LADDER-RVHSS 840615 009209 D22E006 AUX FH BRIDGE 5 CN 0.650 10.92 MOVE AFH BRIDGE 840615 009206 D22E010 RCS WATER LEV. CNTRL 2 OP 0.208 3.03 HOOK UP N-2 TO HOT LEGS AND PRESSURIZER

  • 840615 009206 D22E010 RCS W7 TER LEV. CNTRL 1 HP 0.115 1.53 HOOK UP N-2 TO HOT LEGS AND PRES $URIZER 840615 009208 D45J003 P.C. ELECTRICAL 3 CN 0.290 5.83 REPLAC2 TROLLEY BUMPER BLOCKS 840618 009214 D20A001 RX DISASSEMBLY PREP 15 CN 1.407 25.88 CHECK LEVEL OF IIF AND RIGGING 840618 009217 D20A001 RX DISASSEMBLY PREP 12 IC 1.039 23.10 ROUTINE POLAR CRANL OPERATIONS
  • 840618 009217 D20A001 RX DISASSEMBLY PREP 6 MM 0.363 7.42 ROUTINE' POLAR CRANE OPERATIONS 840618 009218 D22E010 RCS WATER LEV. CNTRL 7 OP 0.438 5.65 VENT CRO K-9/0 PEN VLVS/St9LRE N-2 TO PZR
  • 840618 009218 D22E010 RCS WATER LEV. CNTRL 4 HP 0.324 3.13 VENT CRD K-9/0 PEN VLVS/ SECURE N-2 TO PZR
  • 840618 009218 D22E010 RCS WATER LEV. CNTRL 2 CN 0.098 1.98 VENT CRD K-9/0 PEN VLVS/ SECURE N-2 TO PZR 840618 009215 D45J003 P.C. ELECTRICAL 2 CN 0.092 2.47 AEPLACE TROLLEY STOPS 840618 009216 D45J003 P.C ELECTRICAL 2 EL 0.115 2.77 DEFEAT TROLLEY LIMIT SWITCH s

840619 009243 D20A001 RX DISASSEMBLY PREP 13 CN 0.973 21.35 CHECK IIF AND LINKAGE FOR LEVEL h$ 840620 009252 D20A001 RX DISASSEMBLY PREP 28 CN 2.358 46.18 IIF LEVEL CHECKS 840621 009258 D22E006 AUX F H BRIDGE 2 CN 0.260 2.70 INSTALL ANTI-0VERTURN DEVICES e 840621 00G268 D22E006 AUX FH BRIDGE 3 CN 0.191 3.27 RE-INSTALL 5 TON NOIST 840621 009260 D22E013 SERVICE AIR 6 CN 0.742 8.80 CHANGE OUR AIR CONNECTOR AND TEMPERATURE 840621 009257 D35E002 SHLD HEAD STOR STAND 19 CN 2.762 34.15 STAGE, SHIELDING EQUIPMENT 840S22 0092'1 D20A001 RX DISASSEMBLY PREP 2 CN 0.107 2.13 INSTALL 120 VOLT POWER TO 'D* RING 840622 009272 D20A001 RX DISASSEMBLY PREP 7 CN 0.538 11.18 HEADLIFT TARGET CAMERAS-POLAR CRANE 840622 009269 D22E005 CRDM REMOVAL 2 CN 0.140 2.72 CRDM TOP CLOSURE / STAGE BULLARD

  • 840622 009269 D22E005 CRDM REMOVAL 1 UM 0.050 1.00 CRDM TOP CLOSURE / STAGE BULLARD
  • 840622 009769 D22E005 CRDM REMOVAL 2 MM 0.109 2.23 CRDM TOP CLOSURE /MTAGE BULLARD
  • 840622 009269 D22E005 CRDM REMOVAL 1 CM 0.050 1.28 CRDM TOP CLOSURE / STAGE BULLARD 840622 009273 D22E012 CANAL ACCESS 4 CN 0.382 8.49 RE-INSTALL STAIR SCAFFOLD 840622 009270 D45J003 P.C ELECTRICAL 2 EL 0.158 3.22 RESTORE AND TEST TROLLEY LIMIT SWITCH 840623 009281 D20A001 RX DISASSEMBLY PREP 4 CN 0.303 6.77 REALIGN HEADLIFT TARGET CAMERAS 840623 009283 D20A001 RX DISASSEMBLY PREP 2 CN 0.076 0.97 INSTALL WELDING MACHINE 840623 009282 D20F001 FUEL CAN%L MODS.

5 CN 0.620 9.78 PROVIDE CANAL AREA LIGHTING 840623 009284 D20F001 FUEL CANAL MODS. 14 CN 1.448 25.88 INSTALL FUEL XFER POOL DRAIN MANIFOLD 840623 009287 P45J003 P.C. ELECTRICAL 4 EL 0.330 6.52 REPAIR POLAR CRANE 840625 009294 D20A001 RX DISASSEMBLY PREP 7 EL 0.725 16.43 ROUTINE POLAR CRANE OPERATIONS

  • 840625 009294 D20A001 RX DISASSEMBLY PREP 3 IC 0.715 17.36 ROUTINE POLAR CRANE OPERATIONS
  • 840625 009294 D20A001 RX DISASSEMBLY PREP 1 MM 0.080 2.07 ROUTINE POLAR CRANE OPERATIONS 840625 009290 022E018 HEAD STORAGE STAND 8 UM 1.174 16.15 WORK ON HEAD STORAGE STAND 840625 009295 D35E002 SHLD HEAD STOR STAND 15 CN 1.715 27.85 STAGE EQUIPMENT FOR VIDLO CONSOLE AREA 840626 009311 D22E012 CANAL ACCESS 14 CN 1.539 21.85 CUT CABLE BRIDGES 840626 009308 D35E002 SHLD MEAD STOR STAND 5 UM 0.799 10.62 INSTALL HEAD STORAGE STAND SHIELDING 840626 009309 D35E002 SHLD HEAD STOR STAND 1 IC 0.100 2.05 FILL WATER COLUMNS FOR TEMP. SHIELDING
  • 840626 009309 D35E002 SHLD HEAD STOR STAND 1 EL 0.103 2.05 FILL WATER COLUMNS FOR TEMP. SHIELDING
  • 840626 009309 D35E002 SHLD HEAD STOR STAND 1 CM 0.095 1.95 FILL WATER COLUMNS FOR TEMP. SHIELDING

DATE 022186 PAGE 18 PNO 17 .TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. ,............. T. A S K D E. S.C R I P T. I ON

  • DATE

.N

  • .......UMBE.R....... E. R...........s...I.TY NUMB ACTIV

..ENTRG...... .C. OD E.... R E.M................... HOURS

  • 840626.009309 D35E002 SHLD HEAD STOR STAND 1 OP

. 0.100 1.43 FILL WATER COLUMNS FOR TEMP. SHIELDING

  • 840626 009309 D35E002 SHLD HEAD STOR STAND 1 UM 0.156 2.12 FILL WATER COLUMNS F OR TEMP. SHIELDING 840627 009319 D20A001 RX DISASSEMBLY PREP 10 CN 0.938 15.97 POWE R & CN T R L F OR BUBBLER AIR COMPRESSOR 840627 009321 D220293 RV STUD REMOVAL 22 MM 2.610 50.52 RV STUD DE TENSIONING
  • 840627 009321 D22E003 RV STUD REMOVAL 11 UM 1.384 24.47 RV STUD DETENSIONING
  • 840627 039321 D*?E003 RV STUD REMOVAL 2 EL 0.228 4.55 RV STUD DETENSIONING 840627 009320 D22EC06 AUX FH BRIDGE 4 CN 0.284 7.28 RIG AND INSIALL PLATFORM PLATES 840627 009325 D22E010 RCS WATER LEV. CNTRL 2 CN 0.227 4.60 REMOTE INDICATION FOR PRIMARY WATER 840627 309323 D22E019 INTERNALS INDEX FIXT 40 CN 6.159 83.63 STAGE AND ASSEMBLE IIF PLATFORM 840628 309332 D20F001 FUEL CANAL MODS.

3 CN 0.162 3.46 INSTALL FUEL XFER CANAL DRAIN FUMP

  • 840623 009332 D20F001 FL'E L CANAL MODS.

1 QA 0.081 1.12 INSTALL FUEL XFER CANAL DRAIN PUMP 840624 009331 D22E005 CROM REMOVAL 3 UM 0.248 4.85 CRDM TOP CLOSURE REMOVAL 840628 009337 D22E010 RCS WATER LEV. CNTRL 2 OP 0.026 0.82 INITIATE AND SECURE RCS DRAINDOWN 840628 009336 035E002 SHLD HEAD STOR STAND 1 OP 0.090 1 37 WET VAC RESIDUAL WATER - 347* LEVEL

  • 840628 009336 D35E002 SHLD HEAD STOR STAND 2 CM 0.335 3.15 WET VAC RESIDUAL WATER - 347' LEVEL
  • 840628 009336 D35E002 SHLD HEAD STOR STAND 2 UM 0.181 3.20 WET VAC RESIDUAL WATER - 347' LEVEL 840629 009338 D35E002 SHLD HEAD STOR STAND 7 CN 0.844 12.43 STAGE AND RIG 8' WATER COLUMNS 840629 009339 035E002 SHLD HEAD STOR STAND 11 UM 1,358 23.67 INSTALL HEAD STORAGE STAND SHIELDING 840630 009346 020F001 F UE L CANAL MODS.

3 CN 0.211 5.78 GRIND WELD IN REFUEL CANAL DRAINPIPE 840630 009344 D22E012 CANAL ACCESS 2 CN 0.130 2.52 CUT UP MISCELLANEOUS STEEL 840630 009345 022E023 D RING CATWALK 3 CN 0.173 3.20 STAGE SCAFFOLD - 367* LEVEL TO RVHSS I 840702 009354 D20A001 RX DISASSEMBLY PREP 5 EL 0.506 13.25 ROUTINE POLAR CRANE OPERATIONS LO *840702 009354 D20A001 RX DISASSEMBLY PREP 6 IC 0.667 15.08 ROUTINE POLAR CRANE OPERATIONS LO

  • 140702 009354 D20A001 RX DISASSEMBLY PREP 4 MM 0.429 10.62 ROUTINE POLAR CRANE OPERATIONS

$40702 009351 D22E003 RV STUD REMOVAL 21 MM 2.717 50.05 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS

  • 840702 009351 D22E003 RV STUD REMOVAL 16 UM 2.267 37.87 REMOVF RV STUDS / INSTALL INHIBITOR & PLUGS 2840702 009351 D22E003 RV STUD REMOVAL 2 CM 0.321 5.25 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS
  • 840702 009351 D22E003 RV STUD REMOVAL 2 EL 0.288 4.97 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS 840702 009352 D22E003 RV STUD REMOVAL 4 CN 0.311 4.90 RIG STUD DETENSIONERS TO 305' LEVEL 840702 009356 D22E003 RV STUD REMOVAL 10 CN 1.456 20.98 MOVE 5 STUD STORAGE RACKS INTO CTMT 840702 009357 035E002 SHLD HEAD STOR STAND 8 CN 1.093 20.04 FILL WATER COLUMNS AROUND HEAD STOR STND
  • 840702 009357 D35E002 SHLD HEAD STOR STAND 1 RP 0.081 0.93 FILL WATER COLUMNS AROUND HEAD STOR STND
  • 840702 009357 035E002 SHLD HEAD STOR STAND 3 OP 0.333 5.32 FILL WATER COLUMNS AROUND HEAD STOR STND
  • 840702 009357 D35E002 SHLD HEAD STOR STAND 1 CM 0.140 2.03 FILL WATER COLUMNS AROUND HEAD STOR STND 840702 009358 D35E002 SHLD HEAD STOR STAND 21 UM 2.672 54.13 INSTALL HEAD STORAGE STAND SHIELDING 840703 009373 D22E003 RV STUD REMOVAL 10 CN 0.886 18.87 MOVE AND STAGE STUD STORAGE RACKS 840703 009371 022E019 INTERNALS INDEX FIXT 20 CN 1.447 36.20 ASSEMBLE IIF PLATFORM / INSTALL ENV SKIRT

$840703 C09371 D22E019 INTERNALS INDEX FIXT 1 QA 0.075 1.17 ASSEMBLE IIF PLATFORM / INSTALL ENV SKIRT 840703 009381 D22E019 INTERNALS INDEX FIXT 4 CN 0.449 9.05 INSTALL RCS SAMPLE PUMP 840705 009382 D22E019 INTERNALS INDEX FIXT 5 CN O.335 6.17 UNDER WATER LIGHTING FOR IIF 840705 009383 D35E002 SHLD HEAD STOR STAND 5 CN 0.780 9.65 STAGE 8' WATER COLUMNS 840705 009384 D45J003 P.C. ELECTRICAL 2 EL 0.080 2.05 DEFEAT TROLLEY LIMIT SWITCH 840706 009387 D22E019 INTERNALS INDEX FIXT 3 CN 0.329 4.45 INSTALL RCS SAMPLE PUMP 840707 009395 D22E003 RV STUD REMOVAL 2 MM 0.130 2.15 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS

  • 840707 009395 D22E003 RV STUD REMOVAL 3 UM 0.216 3.28 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS 840707 009393 D22E019 INTERNALS INDEX FIXT 8 CN 0.745 18.25 ASSEMBLE AND ATTACH LIFT RIG TO IIF 840707 005396 D35E002 SHLD HEAD STOR STAND 24 UM 2.214 46.83 INSTALL HEAD 3TORAGE STAND SHIELDING 840709 009399 020A001 RX DISASSEMBLY PREP 2 EL 0.171 3.72 ROUTINE POLAR CRANE OPERATIONS
  • 840709 009399 D20A001 PX DISASSEMBLY PREP 5 IC 0.317 8.37 ROUTINE POLAR CRANE OPERATIONS
  • 840709 009399 D20A001 RX DISASSEMBLY PREP 1 MM 0.078 2.02 ROUTINE POLAR CRANE OPERATIONS

Daft 022186 PACC 19 PNO. 18 .TM1-2 UNC: DOS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY H 286 0 . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP, 840709 009400 D20A001 RX DISASSEMBLY PREP 10 CN 1.405 19.37. .................... SCRIPTICN TASK DF

  • DATE. NUMBER. NUMBER,

ACTIVITY ENTRG CODE. REM. HOURS. INSTALL HEADLIFT PENDANTS 840709 009401 D35E002 SHLD HEAD STOR STAND 6 CN 0.767 13.23 FILL 8* WATER COLUMNS 840710 009418 D22E003 RV STUD REMOVAL 5 CN 0.366 8.32 FMVE STUD STORAGE RACK 3 TO 347' LEVEL 840710 009424 D22E030 REMOVE HEAD 2'CN 0.160 2.28 INSPECT HEADLIfT PENDANfs 840711 009431 D20A001 RX DISASSEMBLY PREP 4 CM 0.448 7.93 RIG HEADLIF T PENDANTS 840711 009426 D22E019 INTERNALS INDEX FIXT 2 CN 0.113 1.92 IIF UNDE R WATER LIGHTING 840711 009430 D22E019 INTERNALS INDEX FIXT 2 CN 0.203 3.95 POWER FOR IIF & ROS SAMFL! F J"P 840711 009425 D22E030 REMOVE HEAD 2 CN 0.292 4.82 MODIFY SERVICE STRUCTURE StPPCRTS 840711 009429 045J003 P.C ELECTRICAL 2 CN 0.071 1.52 REPA!R 5 TON HOIST 840712 009438 D22E029 LIFT MONITRG EQUIP 5 CN 0.449 7.74 INSTALL HE ADtIF T MONITORING SYSTEM

  • 840712 009438 D22E029 LIFT MONITRG EQUIP 2 IC 0.136 2.13 INSTALL HEADLIFT MONITORING SYSTEM 840713 009448 D20F001 FUEL CANAL MODS.

3 CN 0.132 4.00 CANAL-DR AIN PUMP LEAK TEST

  • 840713 003448 D20F001 FUEL CANAL MODS.

1 QA 0.059 1.17 CANAL DRAIN PUMP LEAK TEST 840713 009444 D35E002 SHLD HEAD STOR STAND 4 CN 0.362 6.58 MOVE AND RIG WATER COLUMNS 840714 009459 D20E001 RD&D SUPP-0UTS CTMT 1 IC 0.002 1.18 CALIBRATE E P. TRANSMITTER 840714 009477 022E010 RCS WATER LEV. CNTRL 2 IC 0.205 5.85 IIF PRE-OP TEST $840714 009477 D22E010 RCS WATER LEV. CNTRL 1 CN 0.130 2.07 !!F PR E -OP "TE ST 840716 009457 D20A001 RX DISASSEMBLY PREP 7 EL 0.720 17.5J ROUTINE POLAR CRAME OPERATIONS

  • 840716 009457 D20A001 RX DISASSEMBLY PREP 5 IC 0.340 9.65 ASUTINE POLAR CRANE OPERATIONS
  • 840716 009457 D20A001 RX DISASSEM8LY PRfP 1 MM 0.151 3.50 ROUTINE POLAR CRANE OPERATIONS 840716 009460 D22E029 LIFT MONITRG EQUIP 3 HP 1.059 19.08 INSIALL AREA RADIATION MONITGRING SYSTEM 840716 009456 D35E002 SHLD HEAD STOR STAND 10 CN 1,069 20.20 FILL 8' WATER COLUMNS

[3 840716 009J61 D35E002 SHLD HEAD STOR STAND 47 UM 4.704 105.07 INSTALL HEAD STORAGE STAND SHIELDING 4 43 840716 009474 D35E002 SHLD HEAD STOR STAND 57 CN 8.064 110.35 FILL 4

  • WATER COLUMNS WITH SAND I

840717 009478 D22E019 INTERNALS INDEX FIXT 3 CN 0.164 3.61 STAGE IIF PLATF ORM ACCESS LADDER 840718 009490 D20F001 FUE L CANAL MODS. 5 CN 0.430 12.48 INSTALL FUEL TRANSFER CANAL DRAIN PUMP 840718 009490 D20F001 FUEL CANAL MODS. 1 QA 0.036 1.12 INSTALL FUEL TRANSFER CANAL DRAIN PUMP 840718 009493 D20F001 FUEL CANAL MODS. 2 CN 3.155 4.23 INSTALL POWER TO NEW DR AIN PUMP 840718 009479 D22E019 INTERNALS INDEX FIXT 4 CN 0.774 11.09 INST ALL RV PLENUM MISTING SYSTEM UNIT 840718 009484 D22E030 REMOVE HEAD 3 CN 0.175 4.32 INSTALL CHANNELS UNDER HEAD PEkDT STAND 840718 009488 D22E030 REMOVE HEAD 1 CM 0.131 2.30 STAGE HE AD BOOT / INS;L HE ADLIFT INDICATOR

  • 840718 009488 D22E030 REMOVE HEAD 1 OP

- 0.090 2 10 STAGE HEAD BOOT /INSTL HEADLIFT INDICATOR

  • 840718 009488 D22E030 REMOVE HEAD 1 UM 0 072 2.17 STAGE HEAD BOOT /INSTL HEADLIFT IhDICATOR
  • 840718 009488 D22E030 REMOVE HEAD 1 CN 0.105 2.53 STAGE HEAD BOOT /INSTL HEADLIFT INDICATOP

$840718 009488 022E030 REMOVE HEAD 1 RP 0.110 2.50 STAGE HE AD BOOT /INSTL HE ADLIFT INDICATOR 840719 009494 022E012 CANAL ACCESS 4 CN 0.349 8.75 REMOVE SCAFF OLD F ROM REF UEL CANAL 840720 009504 D41G003 INSPECTION PLATFORM 4 CN 0.149 3.55 INSTALL STIFF LEG ON IIF PLATFOPM 840721 009513 D20F001 FUEL CANAL MODS. 4 CN 0.430 9.45 INSTL 4 IN PUMD IN FUEL FFER CANAL FLOOR 840721 009512 D22E019 INTERNALS INDEX FIXT 11 CN 0.685 15.76 I4 STALL GASKETS & SPACERS ON IIF

  • 840721 009512 D22E019 INTERNALS INDEX FIXT 1 QA 0.020 0.58 INSTALL GASMETS & SPACERS ON IIF 840721 009510 D35E002 SHLD HEAD STOR STAND 94 CN 11.560 189.02 FILL 8' WATER COLUMNS WITH SAND 840722 009517 D22E030 REMOVE HEAD 7 MM 0.435 8.75 INSPECT LEVELS 347' AND 367*
  • 840722 009517 D22E030 REMOVE HEAD 1 MD 0.076 1.38 INSPECT LEVELS 347' AND 367*
  • 840722 009517 022E030 REMOVE HEAD 1 CN 0.105 2.07 INSPECT LEVELS 347' AND 367*

840723 009523 D20A001 RX DISASSEMSLY 8RER 1 EL C 255 6.13 ROUTINE POLAR CRANE OPERATIONS

  • 840723 009523 D20A001 RX DISASSEPELY PREP J IC 0.302 7.15 ROUTINE POLAR CRANE OPERATIONS

$840723 009523 D20A001 RX DISASSEM9LY PREP 2 MM 0.154 4.48 ROUTINE POLAR CRANE OPERATIONS 840723 009540 D20E001 RD&D SUPP-0UTS CTMT 9 CN 0.029 39.53 FLUSH DRAIN / TARE SAMPLE 840723 009522 022E019 INTERNALS TNDEX F IXT 6 CN 0.502 10.75 LEVEL IIF PLATFORM

  • 840723 009522 022E019 INTERNALS INDEX FIXT 4 UM 0.395 8.93 LEVEL IIF PLATFORM

DATE 022186 PAGE 20 PNO. 19- .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP,

  • D. AT.E... NU.MB.E.R. NUMB.E.R........... C. T..I V. I T Y.................. E. N.T RG.. C O.D. E....... E.M.. HO. U R S..

A R

  • 840723 009522 D22E019 INTERNALS INDEX FIXT 2 !C 0.052 1.45 LEVEL IIF PLATFORM

$840723 009522 D22E019 INTERNALS INDEX FIXT 3 OP 0.279 6.97 LEVEL IIF PLATFORM

  • 840723 009522 D22E019' INTERNALS INDEX FIXT 6 MM 0.563 14.03 LEVEL IIF PLATFORM 840723 009541 D22E019 INTERNALS INDEX FIXT 2 MM 0.072 1.73 IIF BUSHING - CAMERA STAND

$840723 009541 D22E019 INTERNALS INDEX FIXT 1 RP 0.037 0.85 !!F BUSHING - CAMERA STAND

  • 840723 009541 022E019 INTERNALS INDEX FIXT 1 CM 0.036 0.82 IIF BUSHING - CAMERA STAND 840723 009538 D22E028 FILL PROVISION 3 CN 0.350 7.05 TEST FUEL TRANSFER CANAL FILL SYSTEM 840723 009539 D22E030 REMOVE HEAD 1 EL 0.099 2.27 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 7 OP 0.620 12.18 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 46 MM 5.694 113.36 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 8 HP 1.295 26.25 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 13 UM 1.513 22.03 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 8 IC 0.835 19.13 HE AD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 2 CM 0.093 2.05 HEAD REMOVAL /IIF INSTALLATI0M 840723 009539 D22E030 REMOVE HEAD 2 RP 0.180 2.90 HEAD REMOVAL /IIr INSTALLATION 840723 009539 D22E030 REMOVE HEAD 4 CN 0.491 7.65 HE AD REMOVAL /IIF INSTALLATION 840723 009520 D35E002 SHLD HEAD STOR STAND 3 UM 0.139 2.87 INSTALL HEAD STORASE STAND SHIELDING 840723 009521 045J003 P.C. ELECTRICAL 2 EL 0.093 1.90 DEFEAT POLAR CRANE LIMIT SWITCH 840724 009543 D22E023 D RING CATWALK 4 CN 0.356 5.50 INSTALL CATWALK - RVHSS TO D RING

- 840724 009546 D22E026 FLOOD LINE 6 CN 0.004 8.23 INSTALL TAG LINES ON MISTING SYSTEM 840724 009547 D22E030 REMOVE HEAD 1 EL 0.098 2.38 REPAIR CAMERA I *840724 009547 022E030 REMOVE HEAO 2 IC 0.341 5.12 REPAIR CAMERA LJ 840725 009548 D22E030 REMOVE HEAD 1 IC 0.137 2.15 REPAIR STUD HOLE CAMERA 840725 009550 D22E030 REMOVE HEAD 4 CN 0.442 6.85 ERECT SCAFFOLD AT HEAD STORAGE STAND 840725 009553 D45J003 P.C. ELECTRICAL 3 EL 0.902 12.62 TROUBLESHOOT AND REPAIR POLAR CRANE $840725 009553 D45J003 P.C. ELECTRICAL 2 HP 0.172 4.45 TROUBLESHOOT AND REPAIR POLAR CRANE 840726 009558 D22E019 INTERNALS INDEX FIXT 9 CN 0.934 17.65 INSTALL IIF PLATFORM 3840726 009558 D2?E019 INTERNALS INDEX FIXT 1 MM 0.080 2.65 INSTALL IIF PLATFORM 840726 009b59 D22E019 INTERNALS INDEX FIXT 2 CN 0.158 3.47 POWER FOR IIF SAMPLE PUMP / LIGHTING 840726 00S$60 D22E019 INTERNALS INDEX FIXT 3 CN 0.302 6.53 RCS SAMPLE PUMP INJTALLATION 840726 009561 D41G003 INSPECTION PLATFORM 6 CN 0.357 10.05 COVER IIF PLATFORM VIA TURNBUCKLES 840726 009554 D45J003 P.C. ELECTRICAL 4 EL 0.399 7.62 TROUBLESHOOT & REPAIR P.C. PE ND. CONTROL $840726 009554 D45J003 P.C. ELECTRICAL 2 CN 0.160 3.78 TROUBLESHOOT & REPAIR P.C. PEND. CONTROL 840727 009562 D22E019 INTERNALS INDEX FIXT 1 OP 0.011 0.47 INSTALL IIF TIEDDwN

  • B40727 009562 022E019 INTERNALS INDEX FIXT 5 UM 0.193 4.77 INSTALL IIF TIEDOWN
  • 840727 009562 D22E019 INTERNALS INDEX FIXT 5 MM O.161 4.42 INSTALL IIF TIEDOWN
  • 840727 009562 D22E019 INTERNALS INDEX FIXT 1 CM 0.010 0.42 INSTALL IIF TIEDOWN 8840727 009562 D22E019 INTERNALS INDEX FIXT 1 RP 0.010 0.45 INSTALL IIF TIEDOWN 840727 009565 022E030 REMOVE HEAD 3 CN 0.293 4.62 REMOVE SCAFFOLD AT HEAD STORAGE STAND 840727 009563 D45J003 P.C Et.?CTRICAL 6 EL 0.576 11.43 TROUBLESMOOT POLAR CRANE 840730 009570 D20A001 RX DILASSEMBLY PREP 3 IC 0.236 6.02 ROUTINE POLAR CRANE OPERATIONS 840730 009572 D22E019 INTERNALS INDEX FIXT 1 CA 0.126 1.93 RCS SAMPLE DUMP INSTALLATION 8840730 009572 D2?EGa9 INTERNALS INDEX FIXT 3 CN 0.288 5.59 RCS SAMPLE DUMP INSTALLATION 840731 009591 D22E012 CANAL ACCESS 3 CN 0.316 6.20 REPLACE SCAFFOLD 840731 009593 D21E019 INTERNALS INDEX FIXT 4 CN 0.238 6.55 REMOVE / DISMANTLE IIF 840731 009592 0227.029 LIF T MON 1TRG EQUIP 10 CN 1.249 20.45 INSTALL AREA RADIATION MONITORING SYSTEM 840802 009608 D20A001 RX DISASSEMBLY PREP 2 CN 0.166 3.07 WORK ON P.C.

HEADLIFT TARGET CAMERA 840803 009613 D22E 006 AUX FM BRIDGE 4 CN 0.396 8.78 REMOVE COVER PLATE / DRILL HOLES 840806 009627 D20A001 RX DISASSEMBLY PREP 3 IC 0.307 8.47 ROUTINE POLAR CRANE OPERATIONS 840813 009679 D20A101 RX DISASSEMBLY PREP 2 IC 0.123 2.98 ROUTINE POLAR CRANE OPERATIONS

DATE 022186 PAGE 21 PNO. 20 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 256 D EXPOS. RWP, . RWP .EXP-TRCK. PERS. DEPT.

  • D. AT.E... NUMBE.R. NUMBE.R.............IVITYACT..........,...............,....E...........H.OURS................................D. E. S.C R I P T I O N ENTRG. COD REM.

TASK

s..

840816 009711 D45J002 P.C. MECHANICAL 3 CN 0.318 8.40 AUXILIARY HOIST MECHANICAL INSPECTION

  • 840816 009711 D45J002 P.C. MECHANICAL 2 MM 0.196 3.93 AUXILIARY HOIST MECHANICAL INSPECTION 840816 009712 D45J003 P.C. ELECTRICAL 1 EL 0.130 2.38 P.C. AUXILEARY HOIST WALKDDWN
  • 840816 009712 D45J003 P.C. ELECTRICAL 1 CN 0.138 2.35 P.C. AUXILEARY HOIST WALKDOWN 840817 009718 D22E019 INTERNALS INDEX FIXT 1 QA 0.075 1.45 IIF PROCESSING HOSE LEAK TEST

$840817 009718 D22E019 INTERNALS INDEX FIXT 1 CN 0,094 2.63 IIF PROCESSING HOSE LEAK TEST 840820 009725 D35E002 SHLD HEAD STOR STAND 1 MM 0.165 3.52 ROUTINE CRANE OPERATIONS 840820 009728 D35E002 SHLD HEAD STOR STAND 14 CN 1.200 21.67 CUT UP AND REMOVE 8' WATER COLUMNS 840822 009752 D45J003 P.C. ELECTRICAL 1 EL 0.120 2.23 P.C. AUXILEARY HOIST WALKDOWN

  • 840822 009752 D45J003 P.C. ELECTRICAL 1 CN 0.133 2.28 P.C. AUXILEARY HOIST WALKDOWN 840827 009776 020A001 RX DISASSEMBLY PREP 2 EL 0.162 4.48 ROUTINE POLAR CRANE OPERATIONS
  • 840827 009776 D20A001 RX DISASSEMBLY PREP 2 IC 0.253 4.35 ROUTINE POLAR CRANE OPERATIONS 840904 009820 020A001 RX DISASSEMBLY PREP 4 IC 0.584 11.47 ROUTINE CRAF.E OPERATIONS 840906 009848 D41G004 PLENUM INSPECTION 5 CN 0.308 11.86 INSPECT PLENUM JACK SEATING SURFACES
  • 840906 009848 D41G004 PLENUM INSPECTION 1 IC 0.034 1.02 INSPECT PLENUM JACK SEATING SURFACES
  • 840906 009848 041G004 PLENUM INSPECTION 1 HP 0.030 2.82 INSPECT PLENUM JACK SE ATING SURFACES 840906 009852 D45J001 P.C.

INSPECTIONS 1 MD 0.062 1.42 POLAR CRANE BRAKE INSPECTION 8840906 009852 D45J001 P.C. INSPECTIONS 1 MM 0.058 1.42 POLAR CRANE BRAKE INSPECTION 8840906 009852 045J001 P.C. INSPECTIONS 1 AD 0.056 1.47 POLAR CRANE BRAKE INSPECTION 840907 009856 D20E002 GANTRY CRANE 4 CN 0.844 7.12 INSTALL TERMINALS / CHECK GANTRY ELECTRIC 340907 009857 020E002 GANTRY CRANE 11 CN 2.452 24.48 GANTRY CRANE INSTALLATION 840907 009855 D41G004 PLENUM INSPECTION 5 CN 0.356 13.22 INSPECT PLENUM SEATING SURFACES-IIF COV e *840907 009855 041G004 PLENUM INSPECTION 1 HP 0.043 3.03 INSPECT PLENUM SEATING SURFACES-IIF COV OJ 840907 009861 045J002 P.C. MECHANICAL 2 MM 0.148 4.22 ADJUST DRUM BRAKES ON POLAR CRANE Cm 840910 009863 D20A001 RX DISASSEMBLY PREP 6 IC 0.502 13.84 ROUTINE CRANE OPERATIONS I *840910 009863 D20A001 RX DISASSEMBLY PREP 1 EL 0.076 1.78 ROUTINE CRANE OPERATIONS 840911 009881 D35E002 SHLD HEAD STOR. STND 18 CN 2.461 32.32 REMcVE SAND FROM REACTOR BUILDING 840911 009880 D41G004 PLENUM INSPECTION 4 CN 0.246 10.07 INSPECT PLENUM JACK SEATING SURFACES 840913 009899 D22E006 AUX FH BRIDGE 4 CN 0.314 8.48 INSTALL BOLTS IN AFH BRIDGE PLATFORM 840913 009902 D22E019 INT. INDEXING FIXT 4 CN 0.462 11.00 REMOVE PLENUM MISTING SYSTEM 840913 009898 D41G003 INSTL INSPECTN PLTFM 4 CN 0.436 6.72 INSTALL PORTABLE PLATFORM - !!F COVER 840913 009898 D41G003 INSPECTION PLATFORM 4 CN 0.436 6.72 INSTALL PORTABLE WORK PLATFORM 840913 009904 045J001 P.C. INSPECTIONS 1 MD 0.065 1.63 POLAR CRANE TASK FORCE INSPECTION 2840913 009904 D45J001 P.C. INSPECTIONS 1 ES 0.060 1.53 POLAR CRANE TASK FORCE INSPECTION

  • 840913 009904 D45J001 P.C. INSPECTIONS 1 CN 0.059 1.62 POLAR CRANE TASK FORCE INSPECTION 840914 009912 D22E006 AUX FH BRIDGE 4 CN 0.308 9.03 ERECT SCAFFOLD IN REFUELING CANAL 840914 009910 D41G002 INSTL INSPECTN TOOLS 2 CN 0.216 3.42 MODIFY PLENUM JACK 840914 009911 D41G004 PLENUM INSPECTION 4 CN 0.182 7.33 INSPECT SEATIMG SURFACE IN PLENUM 840917 009916 D22E003 RV STUD REMOVAL 3 CN 0.479 3.73 REMOVE STUD TENSIONERS FROM RB 840917 009920 D22E006 AUX FH BRIDGE 4 CN 0.203 5.97 AFH BRIDGE ELEC MODS / STAGE & INSTALL EQUIP 840919 009943 022H001 FUEL REMOVAL 3 CN 0.466 6.47 FH BRIDGE WALKDOWN/ CIRCUIT INSPECTION 840919 009944 041G004 PLENUM INSPECTION 5 CN 0.403 11.60 REMOVE / RELOCATE REFUEL CANAL SCAFFOLD 840919 009945 045J001 P.C.

INSPECTIONS 1 MM 0.072 1.88 INSPECT AND PHOTOGRAPH POLAR CRANE

  • 840919 009945 D45J001 P.C. INSPECTIONS 2 EL 0.208 4.52 INSPECT AND PHOTOGRAPH POLAR CRANE
  • 840919 009945 045J001 P.C.

INSPECTIONS 7 CN 0.670 14.92 INSPECT AND PHOTOGRAPH POLAR CRANE 840920 009949 D41G002 INSTL INSPECTN TOOLS 1 QA 0.059 1.82 F1USH HOSE FOR INSTALLING PLENUM TOOLING $840920 009949 D41G002 INSTL INSPECTN TOOLS 1 CN 0.121 2.55 FLUSH HOSE FOR INSTALLING PLENUM TOOLING 840920 009948 D41G004 PLENUM INSPECTION 4 CN 0.367 11.92 MOVE PLATFORM 70 SO. E ND 0F R EF UE L CANAL. 840924 009962 D20A001 RX DISASSEMBLY PREP 1 IC 0.075 1.60 ROUTINE CRANE OPERATIONS 840924 009964 D4SJ002 P.C. MECHANICAL 4 MM 0.306 6.73 ADJUST P.C. BRAKES / INSTALL COTTER PINS 1

DATE 022186 PAGE 22 PNO 21 .TM1-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP

  • .D. A T E... NUMBE.R.......

..UMBE.R...........IVIT.Y.......,.......,. E. N T R G.. CO.D E.. _.. R E.M......U.RS... ................ S. K D E. S.C R I P T I O N N ACT HO TA 840925 009980 D22H001. FUEL REMOVAL 3 CN . 0.351. 9.18 AS-BUILT MEAS OF DAM MEY-REFUEL CANAL 840928 010003 D22E026 FLOOD LINE 2 CN 0.092 1.95 TEST CABLES FOR DWCS USE 840928 010006 D22E028 FILL PROVISION 6 CN 0.071 6.37 FHB WEST HOUSE-CONNECT TEST EQUIP & TEST 840928 010005 D41G002 INSTL INSPECTN TOOLS 4 CN 0.201 10.15 INSPECT AS BUILT PLENUM STORAGE STAND 841001 010010 0416003 INSTL INSPECTN PLTFM 4 CN O.262 8.25 ERECT SCAFFOLD - MAIN FH BRIDGE 841001 010010 D41G003 INSPECTION PLATFORM 4 CN 0.262 8.25 ERECT SCAFFOLD FOR MAIN FH BRIDGE 841002 010029 D22E006 AUX FH BRIDGE 3 CN 0.224 5.78 WALKDOWN/ INSPECT MAIN FH BRIDGE CIRCUITS 841004 010040 D72E006 AUX FH BRIDGE 9 CN 0.708 17.50 AFH BRIDGE ELECTRICAL MODIFICATIONS 841005 010046 D22E006 AUX FH BRIDGE 4 CN 0.272 8.83 REMOVE SCAFFOLD FROM kEFUELING CANAL 841005 010049 D22G001 PLENUM REMOVAL 1 MM 0.055 0.70 CHANGE DESSICANT & AIR FILTER-IIF 441008 010056 D20A001 RX DISASSEMBLY PREP 3 IC 0.326 8.17 ROUTINE CRANE OPERATIONS 841008 010055 045J001 P.C. INSPECTIONS 5 MM 0.542 10.85 INSPECT OPERABILITY OF P.C. COMPONENTS

  • 841008 010055 045J001 P.C.

INSPECTIONS 3 EL 0.361 7.28 INSPECT OPERABILITY OF P.C COMPONENTS 841010 010078 045J001 P.C. INSPECTIONS 6 IC 0.637 15.57 VIBRATION CHECK OF POLAR CRANE

  • 841010 010078 D45J001 P.C.

INSPECTIONS 2 CN 0.156 4.83 VIBRATION CHECK OF POLAR CRANE 841017 010114 D45J001 P.C. INSPECTIONS 3 CN 0.317 7.03 NRC POLAR CRANE INSPECTION

  • 841017 010114 D45J001 P.C.

INSPECTIONS 1 EL 0.100 2.37 NRC POLAR CRANE INSPECTION 841019 010129 D20A001 RX DISASSEMBLY PREP 1 EL 0.104 2.37 ROUTINE CRANE OPERATIONS

  • 841019 G10129 D20A001 RX DISASSEMBLY PREP 2 IC 0.159 3.91 ROUTINE CRANE OPE R AT IONS 841019 010133 D22E028 FILL PROVISION 2 HP 0.032 4.63 FHB WEST HOUSE-CONNECT TEST EQUIP & TEST
  • 841019 010133 D22E028 FILL PROVISION 6 CN 0.160 14.43 FHB WEST HOUSE-CONNECT TEST EQUIP & TEST 841019 010127 D41G002 INSTL INSPECIN TOOLS 7 CN 0.492 8.90 INSTALL / STAGE PAR EQUIPMENT g

841019 010128 D41G002 INSTL INSPECTN TOOLS 3 CN 0.211 3.68 REMOVE U-1 TURN 8UCKLE AND LINK PLATES La 841022 010135 D41G001 INSTALL VIDEO EQUIP. 3 IC 0.213 7.02 PAR COMMUNICATIONS MODS /INSTL POWER CTRS %4 *841022 010135 D41G001 INSTALL VIDEO EQUIP. 7 CN 0.758 14.10 PAR COMMUNICATIONS MGDS/INSTL POWER CTRS e 841022 013138 D41G002 INSTL INSPECTN TOOLS 5 CN 0.355 11.85 STAGE TOOLS & EQUIPMENT FOR PLENUM INSP. 841022 010137 041G004 PLENUM INSPECTION 3 CN 0.192 4.72 MOVE AUX FH BRIDGE PLATFORM 841023 010158 D41G002 INSTL INSPECTN TOOLS 3 CN 0.183 6.33 WAlkDOWN PAR VIDEO EQUIPMENT 841024 010162 D20A001 RX DISASSEMBLY PREP 3 EL 0.222 9.27 ROUTINE CRANE OPERATIONS

  • 841024 010162 D20A001 RX DISASSEM6LY PREP 11 IC 1.087 34.56 ROUTINE CRANE OPERATIONS 841024 010164 D91K002 UPPER A OTSG EXTRNL 1 RP 0.040 0.60 INSPECT
  • A* D RING - 330*&349' LEVELS 2841024 010164 D91K002 UPPER A OTSG EXTRNL 2 HP 0.368 2.78 INSPECT

'A' D RING - 330'&349' LE"ELS 2841024 010164 D91K002 UPPER A OTSG EXTRNL 3 CN 0.655 3.40 INSPECT 'A' D RING - 330'&349' LEVELS 841024 010165 D91K002 UPPER A OTSG EXTRNL 1 HP 0.591 1.15 SAFETY INSPECTION OF

  • A' D RING

$841024 010165 D91K002 UPPER A OTSG EXTRNL 1 AM 0.549 0.93 SAFETY INSPECTION OF 'A' D RING 841025 010170 041G004 PLENUM INSPECTION 66 CN 4.378 208.90 PLENUM INSPECTION-TOP OF IIF COVER 841025 010170 041G004 PLENUM INSPECTION 14 HP 0.665 46.38 PLENUM INSPECTION-TOP OF IIF COVER 841031 010203 D20A001 RX DISASSEMBLY PREP 9 EL 0.693 26.40 ROUTINE CRANE OPERATIONS

  • 841031 010203 D20A001 RX DISASSEMBLY
  • REP 1 CN 0.050 3.03 ROUTINE CRANE OPERATIONS
  • 841031 010203 D20A001 RX DISASSEMBLY PREP 6 IC 0.495 18.05 ROUTINE CRANE OPERATIONS 841101 010208 D41G004 PLENUM INSPECTION 52 CN 3.893 163.35 PLENUM INSPECTION 2841101 010208 D41G004 PLENUM INSPECTION 12 HP 0.676 38.33 PLENUM INSPECTION
  • 841101 010208 D41G004 PLENUM INSPECTION 1 IC 0.088 3.40 PLENUM INSPECTION 841101 010215 D45J003 P.C. ELECTRICAL 2 EL 0.220 4.37 TROUBLESHOOT POLAR CRANE ELECTRICAL SYS 841106 101240 D22H001 FUEL REMOVAL 8 CN 0.886 18.73 REMOVE ELECTRICAL EQUIPMENMI FOR FTS 841107 010247 D20A001 RX DISASSEMBLY PREP 7 EL 0.734 19.24 ROUTINE CRANE OPERATIONS
  • 841107 010247 D20A001 RX DISASSEMBLY PREP 2 CN 0.000 4.93 ROUTINE CRANE OPERATIONS 2841107 010247 D20A001 RX DISASSEMBLY PREP 2 IC 0.157 5.13 ROUTINE CRANE OPERATIONS
  • 841107 010247 D20A001 RX DISASSEMBLY PREP 2 UM 0.000 2.33 ROUTINE CRANE OPERATIONS 841107 010244 D20F001 FUEL CANAL MODS, 4 CN 0.228 7.05 WELD INSPECTION-TRANSFER CANAL DEEP END

DATE 022186 PAGE 23 PNO 22 .TMI-2 UNC-DDS - ACTIVITY REPORT - REA. TOR DEFUEL & DISASSEMBLY M 286 D 2 . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. .......................... TION

  • DAT. NUMBER. NUMBER ACTIVITY ENTRG. CODE REM HOURS.

TASK DESCRIP

  • ....E

................s. 841107 010243 D41G004 PLENUM INSPECTION 2 CN 0.050 2.10 RELOCATE BUBBLER-IIF COVER PLATE 841108 010250 D45J001 P.C. INSPECTIONS 4 MM 0.421 9.58 POLAR CRANE WAtkDOWN AND INSPECTION

  • 841108 010250 D45J001 P.C.

INSPECTIONS 4 EL 0.439 9.22 POLAR CRANT WALkDOWN AND INSPECTION .*841108 010250 D45J001 P.C. INSPECTIONS 4 CN 0.428 10.12 P01AR CRANE WALKDOWN AND INSPECTION 841109 010262 D41G002 INSTL INSPECTN TOOLS 2 CN 0.137 3.07 SLING INSPECTION 841109 010259 D41G004 PLENUM INSPECTION 4 CN 0.286 11.40 PLENUM INSPECTION

  • 841109 010259 D41G004 PLENUM INSPECTION 1 HP 0.044 2.88 PLENUM INSPECTION 841113 010270 D22E003 RV STUD REMOVAL 22 CN 2.259 47.80 S TtSE RX HEAD STUDS IN HEAD FLANGE 841113 010286 D45J001 P,C.

INSPECTIONS 2 EL 0.177 4.10 POLAR CRANE WALKDOWN

  • 841113 010286 D45J001 P.C INSPECTIONS 2 CN 0.202 3.97 POLAR CRANE WALKDOWN 841114 010232 D20A001 RX DISASSEMBLY PREP 6 IC 0.526 12.60 ROUTINE CRANE OPERATIONS
  • 841114 010292 D20A001 RX DISASSEMBLY PREP 1 EL 0.100 3.35 ROUTINE CRANE OPERATIONS 841116 010305 D22E029 LIFT MONIT. EQUIP 1 RC 0.069 2.18 REMOVE HEADLIFT RAD MONITORS /INSTL R0074
  • 841116 010305 D22E029 LIFT MONIT. EQUIP 3 HP 0.234 6.34 REMOVE HEADLIFT RAD MONITORS /INSTL R0074 841116 010304 D41G002 INSTL INSPECTN TOOLS 2 CN 0.213 2.58 TOOL STORAGE WALKDOWN 841116 010303 D45J001 P.C.

INSPECTIONS 3 CN 0.299 5.80 INSPECT AUX HOIST DRUM BEfRING SUPPORT 841116 010306 D45J002 P.C. MECHANICAL 6 EL 0./73 13.80 CONTINUITY AND MEGGER TE! ON HOIST 841120 010329 D41G005 PLENUM JACKING SYS. 2 CN 0.137 2.40 INSTALL FOUR DIAPER CONES 841121 010334 D20A001 RX DISASSEMBLY PREP 1 IC 0.116 2.48 ROUTINE CRANE OPERATIONS 841121 010335 D41G002 INSTL INSPECTN TOOLS 1 IC 0.059 1.30 REPAIR PAR TOOLS AND EQUIPMENT

  • 841121 010335 D41G002 INSTL INSPECTN TOOLS 2 CN 0.120 4.57 REPAIR PAR TOOLS AND EQUIPMENT 841126 010353 D41C005 ELECTRICAL SUPPORT 1 MM 0.003 6.72 INSTALL NEW CABLE & CONDUIT FOR MOD FTS
  • 841126 010353 D41C005 ELECTRICAL SUPPORT 12 CN 0.031 19.63 INSTALL NEW CABLE & CONDUIT FOR MOD FTS gto 841128 010361 D20A001 RX DISASSEMBLY PREP 11 IC 0.837 29.02 ROUTINE CRANE OPERATIONS co 841129 010365 D41G005 PLENUM JACKING SYS.

8 CN 0.828 19.83 INSTALL IIF SHIELDING I 841129 010366 D41G005 PLENUM JACKING SYS. 6 CN 0.519 12.40 STAGE JACKING EQUIPME NT 841129 010367 D50H002 ERM-DEFUEL PLATFORM 3 CN 0.136 7.25 AS-BUILT WALL BRACKETS-REFUEL SANAL 841130 010373 D41G005 PLENUM JACKING SYS. 2 CN 0.093 2.28 REPAIR SEAL LEAK-FUEL TRANSFER CANAL 841130 010376 D41G005 PLENUM JACKING SYS. 3 CN 0.153 3.82 ELECTRICAL CONNECTION TO PLENUM JACK 841130 010378 D41G005 PLENUM JACKING SYS. 66 CN 3.653 156.67 INSTALL PLENUM JACKS-IIF PLATFORM

  • 841130 010378 D41G005 PLENUM JACKING SYS, 4 HP 0.176 10.73 INSTALL PLENUM JACMS-IIF PLATFORM 841130 010374 D55H001 FH BRIDGE & MAST 4 CN 0.138 4.47 MOVE AFH BRIDGE MANUAL DRIVE 841203 010395 D41C005 ELECTRICAL SUPPORT 16 CN 0.031 29.82 INSTALL NEW CABLE & CONDUIT FOR MOD FTS 841203 010381 D41G004 PLENUM INSPECTION 38 CN 2.854 117.20 END FITTIr3 REMOVAL
  • 841203 010381 D41G004 PLENUM INSPECTION 7 HP 0.400 22.07 END FITTING REMOVAL 841203 010382 D41G006 JACK PLENUM 6 CN 0.532 15.68 JACK PLENUM TO 2.5 INCHES 841204 010398 D45J002 P.C.

MECHANICAL 5 EL 0.265 5.93 CONTINUITY AND MEGGER TEST ON P.C.

  • 841204 010398 D45J002 P.C.

MECHANICAL 2 CN 0.182 4.12 CONTINUITY AND MEGGER TEST ON P.C. 841205 010413 D20A001 RX DISASSEMBLY PREP 8 IC 0.613 24.28 ROUTINE CRANE OPERATIONS 2841205 010413 020A001 RX DISASSEMBLY PREP 4 EL 0.319 11.35 ROUTINE CRANE OPERATIONS

  • 841205 010413 D20A001 RX DISASSEMBLY PREP 2 MM 0.116 3.37 ROUTINE CRANE OPERATIONS 841205 010412 041G005 PLENUM JACKING SYS.

5 CN 0.376 14.55 INSTALL PLENUM JACKS AND TEST 841205 010412 D41G005 PLENUM JACKING SYS. 1 HP 0.066 3.12 INSTALL PLENUM JACKS AND TEST 841205 010410 D50H002 ERM-DEFUEL PLATFORM 3 CN 0.126 7.57 AS-BUILT FUEL R ACKS-REFUEL CANAL

  • 841205 010410 D50H002 ERM-DEFUEL PLATFORM 1 QA 0.040 2.37 AS-BUILT FUEL RACKS-REFUEL CANAL 841206 010420 D41G006 JACK PLENUM 8 CN 0.319 10.32 SET UP CENTRAL CONTROL AREA - 347' LEVEL 841207 010423 D91K001 FUEL LOCATING SURVEY 5 CN 0.716 7.07 PLACE AND RETRIEVE TLD*S/ SURVEYS
  • 841207 010423 D91K001 FUEL LOCATING SURVEY 2 HP 0.317 2.80 PLACE AND RETRIEVE TLD'S/ SURVEYS 841207 010424 D91K002 UPPER A OTSG EXTRNL 1 HP 0.156 1.43 REMOVE MIRROR INSULATION - OTSG
  • A'
  • 841207 010424 D91K002 UPPER A OTSG EXTRNL 4 CN 0.478 5.55 REMOVE MIRROR INSULATION - OTSG

'A'

DATE 022186 PAGE 24 PNO. 23 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. ................ S.K DE. SC.R I P T I O N s.D. AT.E... NUMC.E.R.. NU.MB.E.R..........C. T I V I T. Y...............E. N T RG. C. O.DE A ..E.M..... O. U. R S.,........ R H TA 841211 010449 D41G004 PLENUM INSPECTION 38 CN 3.082 112.05 REMOVE END FITTINGS (CORE DEBRIS)& TLD'S

  • 841211 010449 D41G004 PLENUM INSPECTION 7 HP 0.401 22.27 REMOVE END FITTINGS (CORE DEBRIS)& TLD*S 841211 010450 041G006 JACK PLENUM 6 CN 0.476 17.67 JACK PLENUM TO 7.25 INCHES 841211 010448 D91K002 UPPER A OTSG EXTRNL 5 HP 0.605 14.02 SET UP EQUIPMENT / CHARACTERIZE OTSG
  • 841211 010448 D91K002 UPPER A OTSG EXTRNL 2 OP 0.105 4.65 SET UP EQUIPMENT / CHARACTERIZE OTSG
  • 841211 010448 091K002 UPPER A OTSG EXTRNL 4 CN 0.592 12.33 SET UP EQUIPMENT / CHARACTERIZE OTSG
  • 841211 010448 D91K002 UPPER A OTSG EXTRNL 1 IC 0.023 0.73 SET UP EQUIPMENT / CHARACTERIZE OTSG
  • B41211 010448 D91K002 UPPER A OTSG EXTRNL 3 ES 0.441 9.78 SET UP EQUIPMENT / CHARACTERIZE OT5G 841212 010460 D20A001 RX DISASSEMBLY PREP 8 IC 0.712 22.08 ROUTINE CRANE OPERATIONS
  • 841212 010460 D20A001 RX DISASSEMBLY PREP 2 MM 0.187 6.42 ROUTINE CRANE OPERATIONS
  • 841212 010460 D20A001 RX DISASSEMBLY PREP 3 EL 0.247 8.97 ROUTINE CRANE OPERATIONS 841214 010476 04tC005 ELECTRICAL SUPPORT 4 CN 0.361 7.03 INSTALL NEW CABLE & CONDUIT FOR MOD FTS 841214 010475 D55F001 FTS MODIFICATIONS 4 CN 0.398 8.00 INSTALL NEW ELECTRICAL EQUIP FOR F TS 841217 010484 D20H001 DEFUELING WORK PLTFM 8 CN 0.759 21.12 AS-BUILT REFUELING CANAL SHALLOW END 841217 010483 D41C005 ELECTRICAL SUPPORT 4 CN 0.306 5.58 INSTALL NEW CABLE & CONDUIT FOR MOD FTS 841218 010503 D41G004 PLENUM INSPECTION 31 CN 2.989 91.85 REMOVE END FITTINGS /TLD CORE PROBE
  • 841218 010503 D41G004 PLENUM INSPECTION 4 HP 0.348 11.47 REMOVE END FITTINGS /TLD CORE PROSE 841219 010514 D20A001 RX DISASSEMBLY PREP 2 EL 0.189 5.92 ROUTINE CRANE OPERATIONS 2841219 010514 D20A001 RX DISASSEMBLY PREP 3 IC 0.316 9.81 ROUTINE CRANE OPERATIONS
  • 841219 010514 D20A001 RX DISASSEMBLY PREP 2 MM 0.125 5.37 ROUTINE CRANE OPERATIONS 841226 010549 D20A001 RX DISASSEMBLY PREP 1 MM 0.079 2.02 ROUTINE CRANE OPERATIONS 841226 010548 D45J001 P.C.

INSPECTIONS 14 CN 1.434 30.53 FUNCTIONAL TEST OF P.C. COMPONENTS 841226 010547 045J002 P.C. MECHANICAL 2 UM 0.120 3.53 REPLACE FRAYED CABLE ON GOLO HOIST-P.C. LJ *841226 010547 D45J002 P.C. MECHANICAL 2 MM 0.123 3.57 REPLACE FRAYED CABLE ON GOLO HOIST-P.C. uD 841227 010558 D22E003 RV STUD REMOVAL 2 CN 0.113 1.72 REMOVE ONE HALF 0F STUD STORAGE RACK I 841227 010556 D45J002 P.C. MECHANICAL 2 CN 0.187 3.57 CONTINUITY AND MEGGER TEST OF P C. 841227 010557 091K002 UPPER A OTSG EXTRNL 1 HP 0.133 2,08 RECORD DATA FROM DETECTORS 'A' D RING

  • 841227 010557 D91K002 UPPER A OTSG EXTRNL 1 CN 0.163 2.22 RECORD DATA FROM DETECTORS

'A' D RING 841228 010566 091K002 UPPER A OTSG EXTRNL 1 OP 0.025 0.57 RETRIEVE TLD'S 'A' OTSG

  • B' D RING WLKWY
  • 841228 010566 D91K002 UPPER A OTSG EXTRNL 1 HP 0.036 0.67 RETRIEVE TLD'S *A*

OTSG 'B' D RING WLKWY 850103 010597 D20A001 RX DISASSEMBLY PREP 2 MM 0.126 2.82 ROUTINE CRANE OPERATIONS 2850103 010597 D20A001 RX DISASSEMBLY PREP 1 EL 0.026 0.76 ROUTINE CRANE OPERATIONS

  • 850103 010597 D20A001 RX DISASSEMBLY PREP 1 IC 0.099 3.17 ROUTINE CRANE OPERATIONS 850103 010591 D45J001 P.C.

INSPECTIONS 3 CN 0.265 6.98 NRC INSPECTION OF POLAR CRANE 850103 010595 D45J003 P.C. ELECTRICAL 4 CN 0.470 8.55. AUX HOIST ELECTRICAL DEVICE REPLACEMENT 850103 010594 D55F001 FTS MODIFICATIONS 2 CN 0.204 3.73 INSPECT UPENDERS 850104 010603 D91K010 CORE FLOOD LINE 3 CN 0.142 3.03 INSTALL SCAFFOLDING - 305* & 347' LEVELS 850107 010607 D45J002 P.C. MECHANICAL 17 CN 1.487 36.55 REPLACE AUX HOIST BRAKES 850110 010640 D20A001 RX DISASSEMBLY PREP 1 EL 0.140 2.68 ROUTINE CRANE OPERATIONS $850110 010640 D20A001 RX DISASSEMBLY PREP 1 IC 0.029 0.82 ROUTINE CRANE OPERATIONS 850110 010642 D55F001 FTS MODIFICATIONS 8 CN 0.509 18.55 REMOVE AYDL CYLINDERS & UPENDER FRAME 850116 010689 D20A001 RX DISASSEMBLY PREP 1 MM 0.178 3.32 ROUTINE CRANE OPERATIONS

  • 850116 010689 D20A001 RX DISASSEMBLY PREP 2 IC 0.226 5.53 ROUTINE CRANE OPERATIONS
  • 850116 010689 D20A001 RX DISASSEMBLY PREP 1 EL 0.167 3.70 ROUTINE CRANE OPERATIONS 850117 010677 020H001 DEFUELING WORK PLTFM 8 CN 0.448 16.30 CUT HOLES IN SEAL PLATE WORK PLATFORM 850117 010694 D55H001 FH BRIDGE & MAST 6 CN 0.456 12.79 AS BUILT AFH BRIDGE & TROLLEY RAIL 850117 010697 D91K010 CORE FLOOD LINE 1 HP 0.115 1.57 GENERIC RAD SURVEY

'B' CORE FLOOD LINE $850117 010697 D91K010 CORE FLOOD LINE 1 CN 0.120 1.57 GENERIC RAD SURVEY

  • B' CORE FLOOD LINE 850123 010737 D20A001 RX DISASSEMBLY PREP" 1 EL 0.026 0.72 ROUTINE CRANE OPERATIONS 850123 010735 D20F004 RB SERVICE CRANE 12 CN 1.662 34.03 CHECK FOR INTERFERENCE-D RING GANTRY t

DATE 022186 PAGE 25 PNO. 24 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 0 , RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. TASK DESCRIPTION .................................... CODE. REM HOURS. ACTIVITY ENTRG

  • DATE.. NUMBER. NUMBER 850123 010736 D22G001 PLENUM REMOVAL 3 CN 0.258 5.13 WALKDCWN ELECTRICAL FOR CATWALK REMOVAL 850123 010734 D45J002 P.C. MECHANICAL 6 CN 0.678 16.43 CHANGE OIL AND GREASE AUX HOIST 850125 010747 D55H001 FH BRIDGE & MAST 5 CN 0.305 7.15 MAIN FH BRIDGE ELECTRICAL REMOVAL 850133 010776 D20F004 RB SERVICE CRANE 3 CN 0.540 8.05 WALKDOWN RX BUILDING SERVICE CRANE 850201 010789 D20H001 DEFUELING WORK PLTFM 2 IC 0.147 3.73 ROUTINE CRANE OPERATIONS
  • 850201 010789 D20H001 DEFUELING WORK PLTFM 2 MM 0.244 4.75 ROUTINE CRANE OPERATIONS
  • 850201 010789 D20H001 DEFUELING WORK PLTFM 1 EL 0.070 0.97 ROUTINE CRANE OPERATIONS

'850201 010791 D22G001 PLENUM REMOVAL 1 MM 0.047 1.08 CHANGE DESSICANT-IIF AIR COMPRESSOR 850201 010790 D55F001 FTS MODIFICATIONS 19 CN 1.480 31.10 STAGE / INSTALL NEW UNITS / RIG OUT OLD UNIT 850204 010799 D20H001 DEFUELING WORK PLTFM 12 CN 0.492 16.50 CUT HOLES IN SEAL PLATE WORK PLAIFORM E50204 010802 D91K002 UPPER A OTSG EXTRNL 2 HP 0.145 1.43 PLACE AND RETRIEVE TLD'S 'A' OTSG

  • 850204 010802 D91K002 UPPER A OTSG EXTRNL 3 CN 0.178 2.43 PLACE AND RETRIEVE TLD'S

'A' OTSG 850205 010820 D20H001 DEFUELING WORK PLTFM 3 CN 0.275 7.90 AS-BUILT REFUELING CANAL SHALLOW END 850205 010819 D91K010 CORE FLOOD LINE 1 HP 0.110 2.58 INSPECT / MEASUREMENTS 'B' CORE FLOOD LINE 850205 010819 D91K010 CORE FLOOD LINE 1 CN 0.118 2.55 INSPECT / MEASUREMENTS

  • B' CORE FLOOD LINE 850206 010829 D22E005 CRDM REMOVAL 3 CN 0.258 6.88 REMOVE LDSCR SUPPORT TUBE & CRDM
  • 850206 010829 D22E005 CRDM REMOVAL 1 HP 0.065 2.25 REMOVE'LDSCR SUPPORT TUBE & CROM 850208 010842 D20A001 RX DISASSEMBLY PREP 1 EL 0.147 3.62 ROUTINE CRANE OPERATIONS
  • 850208 010842 D20A001 RX DISASSEMBLY PREP 3 IC 0.180 4.32 ROUTINE CRANE OPERATIONS
  • 850208 010842 D20A001 RX DISASSEMBLY PREP 1 MM 0.116 2.87 ROUTINE CRANE OPERATIONS 850208 010845 D22G001 PLENUM REMOVAL 2 CN 0.073 1.73 REROUTE SERVICE AIR HOSES-D RING CATWALK
  • 850208 010845 D22G001 PLENUM REMOVAL 3 IC 0.452 7.94 REROUTE SERVICE AIR HOSES-D RING CATWALK 4s 850208 010843 D45J001 P.C.

INSPECTIONS 2 CN 0.175 4.43 WALKDOWN AUX HOOK UPPER SHEAR NEST C3 850208 010839 D45J002 P.C. MECHANICAL 4 CN 0.362 10.28 INSTALL SCAFFOLD FOR AUX HOIST INSPECT e 850208 010848 D45J003 P.C ELECTRICAL 8 CN 0.918 17.38 AUX HOIST ELECTRICAL DEVICE REPLACEMENT 850213 010878 D41G002 INSTL INSPECTN TOOLS 3 CN 0.148 4.75 STAGE PLENUM INSPECTION TOOLS 850213 010879 D41G002 INSTL INSPECTN TOOLS 1 HP 0.047 2.00 PREP PAR VIDEO EQUIPMENT

  • 850213 010879 D41G002 INSTL INSPECTN TOOLS 3 CN 0.185 6.60 PREP PAR VIDEO EQUIPMENT 850214 010888 D45J003 P.C. ELECTRICAL 12 CN 1.555 29.22 AUX HOIST FUNCTIONAL TESTING 850214 010889 D55F001 FTS MODIFICATIONS 4 CN 0.186 7.18 REMOVE TRANSFER TUBE FLANGE 850214 010885 D91K007 PZR EXTERNAL 2 CN 0.144 1.65 REMOVE MIRROR INSULATION - PRESSURIZER
  • 850214 010885 091K007 PZR EXTERNAL 1 HP 0.150 0.92 REMOVE MIRROR INSULATION - PRESSURIZER 850215 010898 D20A001 RX DISASSEMBLY PREP 1 MM 0.168 3.33 ROUTINE CRANE OPERATIONS 850219 010907 D20A001 RX DISASSEMBLY PREP 4 IC 0.294 11.50 ROUTINE CRANE OPERATIONS
  • 850219 010907 D20A001 RX DISASSEMBLY PREP 2 MM 0.127 5.13 ROUTINE CRANE OPERATIONS
  • 850219 010907 D20A001 RX DISASSEMBLY PREP 3 EL 0.230 7.73 ROUTINE CRANE OPERATIONS 850219 010906 D41G004 PLENUM INSPECTION 31 CN 2.821 96.28 PLENUM INSPECTION
  • 850219 010906 D41G004 PLENUM INSPECTION 7 HP 0.362 19.52 PLENUM INSPECTION 850219 010912 D45J003 P.C. ELECTRICAL 8 CN 0.940 18.82 AUX HOIST FUNCTIONAL TESTING
  • 850219 010912 D45J003 P.C. ELECTRICAL 1 MM 0.087 2.20 AUX HOIST FUNCTIONAL TESTING 850219 010911 055F001 FTS MODIFICATIONS 8 CN 0.285 19.23 TRACK ALIGNMENT FOR UPENDERS 850220 010941 D45J002 P.C. MECHANICAL 8 CN 0.928 18.48 LUBE HOIST BRAKES AND TROLLEY
  • 850220 010941 D45J002 P.C. MECHANICAL 1 CA 0.071 2.52 LUBE HOIST BRAKES AND TROLLEY 850221 010944 D55F001 FTS MODIFICATIONS 4 CN 0.096 1.87 RIG HYDRAULIC UNITS TO 305' LEVEL 850222 010952 D22G001 PLENUM REMOVAL 4 CN 0.292 5.85 REMOVE NORTH D RING CATWALK 850222 010953 D91K010 CORE FLOOD LINE 2 CN 0.035 1.23 REMOVE SCAFFOLD AT CORE FLOOD TANK 850225 010959 D20A001 RX DISASSEMBLY PREP 4 EL 0.259 9.77 ROUTINE CRANE OPERATIONS
  • 850225 010959 D20A001 RX DISASSEMBLY PREP 7 MM 0.627 19.83 ROUTINE CRANE OPERATIONS
  • 850225 010959 D20A001 RX DISASSEMBLY PREP 5 IC 0.454 14.27 ROUTINE CRANE OPERATIONS 850225 010962 D41G004 PLENUM INSPECTION 16 CN 1.487 47.52 PLENUM INSPECTION

DATE 022186 PAGE 26 PNO. 25 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBL Y M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP, ............... A S. K..D. E. S.C. R I P.T I O N

  • D A T E... NU.MB. E. R.... NUMB E. R..,...... AC. T. I V I T. Y

.......,......... E. N T R G. C. O.D. E.. .....E.M........ R S.......... R HOU T ,P LE NUM INSPECTION 4 HP 0.237 12.08 PLENUM INSPECTION

  • 850225 010962 D41G004 850225 010965 045J003 P.C. ELECTRICAL 6 CN O.707 14.35 AUX HOIST FUNCTIONAL TESTING 850225 010961 D55H001 FH BRIDGE & MAST 4 CN 0.415 8.42 LUBE AND INSPECT MAIN FH BRIDGE 850226 010987 D45J002 P.C.

MECHANICAL 22 CN 1.763 51.63 INSPECT SHEAVES / LUBE AUX HOOK WIRE R0PE

  • 850226 010987 D45J002 P.C MECHANICAL 1 MD 0.100 2.92 INSPECT SHEAVES / LUBE AUX HOOK WIRE ROPE 850226 010989 055H001 FH BRIDGE & MAST 4 CN 0.419 8.58 STAGE TOOLS FOR MAIN FH BRIDGE REMOVAL 850228 011004 D55H001 FH BRIDGE & MAST 68 CN 3.425 84.47 CUT MAIN FH BRIDGE 850304 011030 D20A001 RX DISASSEMBLY PREP 2 EL 0.147 4.88 ROUTINE CRANE OPERATIONS
  • 850304 011030 D20A001 RX DISASSEMBLY PREP 3 MM 0.274 8.40 ROUTINE CRANE OPERATIONS
  • 850304 011030 D20A001 RX DISASSEMBLY PREP 2 IC 0.145 4.18 ROUTINE CRANE OPERATIONS 850305 011048 D55F001 FTS MODIFICATIONS 7 CN 0.928 15.07 STAGE UPENDERS & LATCH ASSY'S IN CANAL 850305 011060 D55F001 FTS MODIFICATIONS 6 CN 0.323 13.18 INSTALL UPENDERS/ ALIGN AND DRILL 850307 011072 D55F001 FTS MODIFICATIONS 7 CN 0.697 15.93 TERMINATE EXISTING CABLES FOR FTS 850307 011071 D91K008 P2R SURGE LINE 5 CN 1.060 7.15 SPECIROMETER READINGS-PZR & SURGE LINE
  • 850307 011071 D91K008 PZR SURGE LINE 2 HP 0.307 4.18 SPECTROMETER READINGS-PZR & SURGE LINE 850311 011081 D20A001 RX DISASSEMBLY PREP 5 EL 0.453 13.18 ROUTINE CRANE OPERATIONS
  • 850311 011081 020A001 RX DISASSEMBLY PREP 8 MM 0.889 18.88 ROUTINC CRANE OPER ATIONS
  • 850311 011081 D20A001 RX DISASSEMBLY PREP 4 IC 0.465 11.27 ROUTINE CR ANE OPERATIONS 850311 011085 D55F001 FTS MODIFICATIONS 19 CN 0.947 56.83 INSTALL UPENDERS/ ALIGN AND DRILL 850312 011104 D55H001 FH BRIDGE & MAST 29 CN 2.612 62.82 DISMANTLE AND CUT UP MAIN FH BRIDGE d50314 011127 D220001 PLENUM REMOVAL 4 CN 0.271 5.12 REINSTALL NORTH D RING CATWALK 850314 011128 D91K008 PZR SURGE LINE 3 HP 0.927 6.48 DATA ACQUISITION-PZR & SURGE LINE d') *850314011128 D91K008 PZR SURGE LINE 2 CN 0.784 2.40 DATA ACQUISITION-PZR & SURGE LINE
  • 850314 011128 D91K008 PZR SURGE LINE 2 RP 0.968 2.80 DATA ACQUISITION-PZR & SURGE LINE
  • 850314 011128 D91K008 PZR SURGE LINE 2 ES 0.543 3.80 DATA ACQUISITION-PZR & SURGE LINE 850315 011138 D55F001 FTS MODIFICATIONS 2 CN 0.089 1.97 REMOVE 2 FH BRIDGE RAIL STOPS 850318 011147 D20A001 RX DISASSEMBLY PREP 4 EL 0.494 12.00 ROUTINE CRANE OPERATIONS
  • 850318 011147 D20A001 RX DISASSEMBLY PREP 5 IC 0.668 15.32 ROUTINE CRANE OPERATIONS
  • 850318 011147 D20A001 RX DISASSEMBLY PREP 6 MM 0.423 10.78 ROUTINE CRANE OPERATIONS 850318 011143 D55H001 FH BRIDGE & MAST 28 CN 3.040 63.35 DISMANTLE AND CUT UP MAIN FH BRIDGE 850319 011166 D41G004 PLENUM INSPECTION 8 CN 0.494 16.83 MOVE AUX FH BRIDGE 850319 011168 D91K008 PZR SURGE LINE 1 HP 0.512 1.25 DATA ACQUISITION-PZR & SURGE LINE
  • 850319 011168 091K008 PZR SURGE LINE 2 CN 1.026 2.40 DATA ACQUISITION-PZR & SURGE LINE
  • 850319 011168 D91K008 PZR SURGE LINE 1 ES 0.060 1.40 DATA ACQUISITION-P2R & SURGE LINE 850320 011175 D41G004 PLENUM INSPECTION 20 CN 1.593 55.06 STAGE EQUIP / MEASURE RADIAL / LOCATE FUEL
  • 850320 011175 D41G004 PLENUM INSPECTION 2 HP 0.087 5.77 STAGE EQUIP / MEASURE RADIAL / LOCATE FUEL 850320 011171 D55F001 FTS MODIFICATIONS 3 CN 0.325 7.23 TERMINATE CABLE FOR FTS 850321 011180 D45J002 P.C.

MECHANICAL 1 QA 0.056 1.30 FINAL INSPECTION-AUX HOIST BRAKES

  • 850321 011180 D45J002 P.C. MECHANICAL 2 CN 0.245 3.75 FINAL INSPECTION-AUX HOIST BRAKES 850321 011185 D45J002 P.C. MECHANICAL 4 CN 0.422 10.53 CLEAN AREA /NDE AUX HOOK
  • 850321 011185 D45J002 P.C.

MECHANICAL 1 MD 0.126 2.77 CLEAN AREA /NDE AUX HOOK 850321 011189 091K001 FUEL LOCATING SURVEY 3 CN 0.569 4.97 GAMMA CAMERA DATA ACQU!SITION-PZR HEAD 2850321 011189 D91K001 FUEL LOCATING SURVEY 1 HP 0.385 1.77 GAMMA CAMERA DATA ACQUISITION-PZR HE%D

  • 850321 011189 D91K001 FUEL LOCATING SURVEY 1 ES 0.271 1.80 GAMMA CAMERA DATA ACQUISITION-PZR HEAD 850322 011194 D45J002 P.C.

MECHANICAL 9 CN 1.012 24.10 MODIFY UPPER LIMIT SWITCH / REMOVE SHEAVE 850322 011195 D45J003 P.C. ELECTRICAL 3 CN 0.336 9.12 REPLACE AUX HOIST ZERO SPEED SWITCH 850325 011197 D20A001 RX DISASSEMBLY PREP 4 EL 0.273 7.37 ROUTINE CRANE OPERATIONS

  • 850325 011197 D20A001 RX DISASSEMBLY PREP 4 MM 0.293 8.07 ROUTINE CRANE OPERATIONS
  • 850325 011197 D20A001 RX DISASSEMBLY PREP 4 IC 0.354 9.78 ROUTINE CRANE OPERATIONS 850325 011198 D45J003 P.C. ELECTRICAL 3 CN 0.245 6.25 REPLACE AUX HOIST ZERO SPEED SWITCH

DATE 022186 PAGE 27 PNO. 26 .THI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. ........................IPTION

  • ....... NUMBER..........................IVITY ENTRG. CODE REM HOURS TASK DESCR NUMBER ACT
  • DATE 850326 011224 D55H001 FH BRIDGE A MAST 10 CN 0.800 23.43 RIG MATERIAL / CLEAN UP CUTTING AREA 850326 011229 D91K001 FUEL LOCATING SURVEY 2 HP 0.255 1.83 GAMMA CAPERA DATA ACQUISITION-PZR HEAD 850327 011239 D45J003 P.C. ELECTRICAL 3 CN 0.177 4.20 AUX HOIST SLOW SFEED MOTOR CHECK 850328 011246 D45J002 P.C. MECHANICAL 6 CN 0.522 17.43 REMOVE 5 TON HOIST / REPAIR LIMIT SWITCH 850328 011242 D45J006 POLAR CRANE P.M.

18 CN 1.731 40.95 AUX HOIST LOAD TEST 850416 011403 D41G003 INSPECTION PLATFORM 4 CN 0.100 5.45 MAKE HANDRAILS REMOVABLE l GRAND-TOTAL - PERS ENTRG. 4809 507.38000 EXPOS REM = 10493.740 RWP HOURS = END REPORT t b N I

4.0 COMPUTER REPORTS 4.4 Activity Report - Reactor Defueling and Disassembly (individual work activities),

DATE 022186 PAGE 2 PNO 1 .TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 0 . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP .....S.CRIPTION

  • DATE. NUMBER. NUMBER ACTIV ENTRG.

REM HOURS. TA DE

  • ....................................ITY

..C. ODE ......................SK 790423 022682 D20A001 RX DISASSEMBLY PREP 4 CN 0.125 DNA . CLEAN UP AREA FOR CRANE USE 821122 005157 D20A001 RX DISASSEMBLY PREP 1 HP 0.267 2 40 RADIATION SURVEY / JOB COVERAGE 821209 005283 D20A001 RX DISASSEMBLY PREP 3 MM 0 346 4.88 INSPECT HEAD LIFY EQUIPMENT

  • 821209 005283 D20A001 RX DISASSEMBLY PREP 3 CN 0.420 5.22 INSPECT HE AD LIFT EQUIPME NT 821217 005354 D20A001 RX DISASSEMBLY PREP 1 CN 0.075 1.25 INSPECT HEAD LIFT EQUIPMENT 821223 005394 D20A001 RX DISASSEMBLY PREP 2 CN 0.352 4.40 WLKDWN REFUEL POOL / PHOTO FUEL XFER EQUIP
  • 821223 008394 D20A001 RX DISASSEMBLY PREP 1 HP 0.180 2.05 WLKDWN REFUEL POOL / PHOTO FUEL XFER EQUIP 830112 005541 D20A001 RX DISASSEMBLY PREP 2 CN 0.103 2.92 PHOTOGRAPH F UEL TRANSFE R EQUIPMENT
  • 830112 005541 D20A001 RX DISASSEMBLY PREP 1 HP 0.054 1.35 PHOTOGRAPH FUEL TRANSFER EQUIPMENT 830406 006217 D20A001 RX DISASSEM8LY PREP 4 CN O 902 11.07 INSTALL GANTRY CRANE RUNNING RAIL 830407 006223 D20A001 RX DISASSEMBLY PREP 2 CN 0.210 3.50 TAKE ELEVATIONS FOR CRANE 830407 006224 D20A001 RX DISASSEMBLY PREP 2 CN 0.201 2.57 CLEAN / INSPECT LIFTING LUGS 830429 006373 D20A001 RX DISASSEMBLY PREP 1 QA 0.114 1.43 INSPECT LIFTING LUGS ON REACTOR VESSEL 830520 006548 D20A001 RX DISASSEMBLY PREP 4 CN 0.549 7.78 INSTALL ANCHOR BOLTS AND RUNWAY RAIL 830526 006594 D20A001 RX DISASSEMBLY PREP 2 CN 0.242 4.07 REPAIR HOLES IN CONCRETE 830608 006674 D20A001 RX DISASSEMBLY PREP 1 QA 0.139 2.02 MEASURE WELDS ON HEAD HANDLING FIXTURE
  • 830608 006674 D20A001 PX DISASSEMBLY PREP 1 CN 0.112 2.05 MEASURE WELDS ON HEAD HANDLING FIXTURE 830624 006797 D20A001 RX DISASSEMBLY PREP 3 CN 0.484 6 58 PHOTOGRAPH / INSPECT HEAD HANDLING FIXTURE
  • 830624 006797 D20A001 RX DISASSEMBLY PREP 1 CA 0.209 2.62 PHOTOGRAPH / INSPECT HEAD HANDLING FIXTURE 830628 006829 D20A001 RX DISASSEMBLY PREP 1 QA 0.172 2,47 INSPECT WELDS ON HEAD HAhDLING FIXTURE
  • 830628 006829 D20A001 RX DISASSEMBLY PREP 1 CN 0.171 2 73 INSPECT WELDS ON HEAD HANDLING FIXTURE 830705 006859 D20A001 RX DISASSEMBLY PREP 1 CN 0.106 1.33 INSPECT WELDS ON HEAD HANDLING FIXTURES
  • 830705 006859 D20A001 RX DISASSEMBLY PREP 1 QA 0.107 1.28 INSPECT WELDS ON HEAD HANDLING FIXTURES 840217 008479 D20A001 PX DISASSEMBLY PREP 2 CN 0.245 3.25 CONTAIMMENT INSPECTION 8

840328 008722 D20A001 RX DISASSEMBLY PREP 2 EL 0.122 3.08 ROUTINE POLAR CRANE OPERATIONS SUPPORT Jh *840328 008722 D20A001 RX DISASSEMBLY PREP 1 MM 0.156 2.60 ROUTINE POLAR CRANE OPERATICNS SUPPOR T 45 840404 008762 D20A001 RX DISASSEMBLY PREP 1 MM 0.113 2.40 ROUTINE POLAR CRANE OPERATIONS 8 840409 008785 D20A001 RX DISASSEMBLY PREP 6 MM 0.773 13.43 ROUTINE POLAR CRANE OPERATIONS

  • 840409 008785 D20A001 RX DISASSEMBLY PREP 1 EL 0.115 2.18 ROUTINE POLAR CRANE OPERATIONS 840416 008826 020A001 RX DISASSEMBLY PREP 1 EL 0.090 1.75 ROUTINE POLAR CRANE OPERATIONS 840419 008855 D20A001 RX DISASSEMBLY PREP 1 MM 0.050 1.48 ROUTINE POLAR CRANE OPERATIONS 840425 008888 D20A001 RX DISASSEMBLY PREP 3 EL 0.391 7.50 ROUTINE POLAR CRANE OPERATIONS
  • 840425 008888 D20A001 RX DISASSEMBLY PREP 3 MM 0.405 7.51 ROUTINE POLAR CRANE OPERATIONS 840430 008912 D20A001 RX DISASSEMBLY PREP 3 EL 0 397 7.28 ROUTINE POLAR CRANE OPERATIONS 840507 008950 D20A001 RX DISASSEMBLY PREP 3 EL 0.256 5 30 ROUTINE POLAR CRANE OPERATTONS
  • 840807 008950 D20A001 RX DISASSEMBLY PREP 2 MM 0.328 6.18 ROUTINE POLAR CRANE OPERATIONS 840509 008970 D20A001 RX DISASSEMBLY PREP 6 UM 1.090 16.82 RESTAGE TCOLS IN CONTAIhMENT 840509 008973 D20A001 RX DISASSEMBLY PREP 4 CN 0.955 17.68 REFURBISH WALL MOUNTED JIB CR z

S40509 008974 D20A001 RX DISASSEMBLY PREP 2 UM 0.273 2.38 MOVE CRDM H-8 TO POOL / MOVE

  • 840509 008974 D20A001 RX DISASSEMBLY PREP 1 MM 0.140 2.67 MOVE CRDM H 8 TO POOL / MOVE
  • 840509 008974 D20A001 RX DISASSEMBLY PREP 1 EL 0.117 5.18 MOVE CRDM H-8 TO POOL / MOVE' K

840514 008994 D20A001 RX DISASSEMBLY PREP 7 EL 0.842 15.58 ROUTINE POLAR CRANE OPERATI NS

  • 840514 008994 D20A001 RX DISASSEMBLY PREP 2 MM 0,210 3.70 ROUTINE POLAR CRANE OPERATIONS 840514 008995 D20A001 RX DISASSEMBLY PREP 3 CN 0.306 4.07 REFURBISH JIB CRANE 840515 009012 D20A001 RX DISASSEMBLY PREP 6 CN 0.504 7.77 MOVE STUD STORAGE RACK INTO REACTOR BLDG
  • 840515 009012 D20A001 RX DISASSEMBLY PREP 1 CA 0.067 0.97 MOVE STUD STORAGE RACK INTO REACTOR BLDG 840516 009019 D20A001 RX DISASSEMBLY PREP 2 UM 0.179 3.02 MOVE CABLE PLATFORM HANDRAIL
  • 840516 009019 D20A001 RX DISASSEMBLY PREP 1 MM 0.151 2.50 MOVE CABLE PLATFORM HANDRAIL
  • 840516 009019 D20A001 RX DISASSEMBLY PREP 1 EL 0.147 2.50 MOVE CABLE PLATFORM HANDRAIL 840521 009034 D20A001 RX DISASSEMBLY PREP 2 MM 0.154 3.78 ROUTINE POLAR CRANE OPERATILNS

DATE 022186 PAGE 3 PNO. 2 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D

  • DATE. RWP

.EXP-TRCK. PERS _ DEPT EXPOS. RWP.

  • ...... NUMB.E.R.......ER..............IVITY............

.....E.......E.M.......S..................................IPTION NUMB ACT ENTRG. COD R HOUR TASK DESCR .............o..,

  • 840521 009034 020A001 RX DISASSEMBLY PREP 4 EL 0.345.

7.67 ROUTINE POLAR CRANE OPERATIONS 840530 009096 D20A001 RX DISASSEMBLY PREP 1 MM 0.132 2.73 ROUTINE POLAR GRANE OPERATIONS 840604 009120 D20A001 RX DISASSEMBLY PREP 1 EL 0.091 1.72 ROUTINE POLAR JRANE OPERATIONS

  • 840604 009120 D20A001 RX DISASSEMBLY PREP 3 IC 0.256 5.65 ROUTINE POLAR CRANE OPERATIONS 840611 009166 D20A001 RX DISASSEMBLY PREP 3 EL 0.183 3.90 ROUTINE POLAR CRANE OPERATIONS
  • 840611 009166 D20A001 RX DISASSEMBLY PREP 2 MM 0.171 2.90 ROUTINE POLAR CRAN 1 OPERATIONS
  • 840611 009166 D20A001 RX DISASSEMBLY PREP 5 IC 0.422 8.23 ROUTINE POLAR CRANE OPERATIONS 840615 009210 D20A001 RX DISASSEMBLY PREP 2 UM 0.070 1.43 INSTALL TEMPORARY LADDER-RVHSS 840618 009214 D20A001 RX DISASSEMBLY PREP 15 CN 1.407 25.88 CHECK LEVEL OF IIF AND RIGGING 840618 009217 D20A001 RX DISASSEMBLY PREP 12 IC 1.039 23.10 ROUTINE POLAR CRANE OPERATIONS
  • 840618 009217 D20A001 RX DISASSEMBLY PREP 6 MM 0.363 7.42 ROUTINE POLAR CRANE OPERATIONS 840619 009243 D20A001 RX DISASSEMBLY PREP 13 CN 0.973 21.35 CHECK IIF AND LINKAGE FOR LEVEL 840620 009252 D20A001 RX DISASSEMBLY PREP 28 CN 2.358 46.18 IIF LEVEL CHECKS 840622 009271 D20A001 RX DISASSEMBLY PREP 2 CN 0.107 2.13 INSTALL 120 VOLT POWER TO

'D' RINO 840622 009272 D20A001 RX DISASSEMBLY PREP 7 CN 0.538 11 18 HEADLIFT TARGET CAMERAS-POLAR CRANE 840623 009281 D20A001 RX DISASSEMBLY PREP 4 CN 0.303 6.77 REALIGN NEADLIFT TARGET CAMERAS 840623 009283 D20A001 RX DISASSEMBLY PREP 2 CN 0.076 0.97 INSTALL WELDING MACHINE 840625 009294 D20A001 RX DISASSEMBLY PREP 7 EL 0.725 16.43 ROUTINE POLAR CRANE OPERATIONS

  • 840625 009294 D20A001 RX DISASSEMBLY PREP 8 IC 0.715 17.36 ROUTINE POLAR CRANE OPERATIONS
  • 840625 009294 D20A001 RX DISASSEMBLY PREP 1 MM 0.080 2.07 ROUTINE POLAR CRANE OPERATIONS 840627 009319 D20A001 RX DISASSEMBLY PREP 10 CN 0.938 15.97 PDWER & CNTRL FOR BUBBLER AIR COMPRESSOR 840702 009354 D20A001 R V. DISASSEMBLY PREP 5 EL 0.50*

13.25 ROUTINE POLAR CRANE OPERATIONS

  • 840702 009354 D20A001 RX DISASSEMBLY PREP 6 IC 0.667 15.08 ROUTINE POLAR CRANE OPERATIONS I *840702 009354 D20A001 RX DISASSEMBLY PREP 4 MM 0.429 10.62 ROUTINE POLAR CRANE OPERATIONS 45 840709 009399 D20A001 RX DISASSEMBLY PREP 2 EL 0.171 3.72 ROUTINE POLAR CRANE OPERATIONS OM *840709 009399 D20A001 RX DISASSEMBLY PREP 5 IC 0.317 8.37 ROUTINE POLAR CRANE OPERATIONS
  • 840709 009399 D20A001 RX DISASSFMBLY FREP 1 MM 0.078 2.02 ROUTINE POLAR CRANE OPERATIONS 840709 009400 D20A001 RX DISASSEMBLY PREP 10 CN 1.405 19.37 INSTALL HEADLIFT PENDANTS 840711 009431 D20A001 RX DISASSEMBLY PREP 4 CN 0.448 7.93 RIG HEADLIFT PENDANTS 840716 009457 D20A301 RX DISASSEMBLY PREP 7 EL 0.720 17.53 ROUTINE POLAR CRANE OPERATION 3
  • 840716 009457 D20A001 RX DISASSEMBLY PRE P 5 IC 0.340 9.65 ROUTINE POLAR CRANE OPERATIONS
  • 840716 009457 D20A001 RX DISASSEMBLY PREP 1 MM 0.151 3.50 ROUTINE POLAR CRANE OPERATIONS 840723 009523 D20A001 RX DISASSEMBLY PREP 3 EL 0.265 6.13 ROUTINE POLAR CRANE OPERATIONS
  • 840723 009523 D20A001 RX DISASSEMBLY PREP 3 IC 0.302 7.15 ROUTINE POLAR CRANE OPCRATIONS
  • 840723 009523 D20A001 RX DISASSEMBLY PREP 2 MM 0.154 4.48 ROUTINE FOLAR CRANE OPERATIONS 840730 009570 020A001 RX OISASSEMBLY PREP 3 IC 0.236 6.02 ROUTINE POLAR CRANE OPEF ATIONS 840802 009608 D20A001 RX DISASSEMBLY PREP 2 CN 0.166 3.07 WORK CN PC. HEADLIFT TARGET CAMERA 840806 009627 D20A001 RX DISASSEMBLY PRE P 3 7C 0.307 8.47 ROUTINE POLAR CRANE OPERATIONS 840813 009679 D20A001 RX DISASSEMBLY PREP 2 IC 0.123 2.98 ROUTINE POLAR CRANE OPERATIONS 840827 009776 D20A001 RX DISASSEMBLY PREP 2 EL 0 162 4.48 ROUTINE POLAR CRANE OPERATIONS
  • 840827 009776 D20A001 RX DISASSEMBLY PREP 2 IC 0.253 4.35 ROUTINE POLAR CRANE OP!RATICNS 840904 009820 D20A001 RX DISASSEMBLY PREP 4 IC 0.584 11.47 ROUTINE CRANE OPERATIONS 840910 009863 D20A001 RX DISASSEMBLY PREP 6 IC 0.502 13.84 ROUTINE CRANE OPERATIONS
  • 840910 009863 D20A001 RX DISASSEMBLY PREP 1 EL 0.076 1.78 ROUTINE CRANE OPERATIONS 840924 009962 D20A001 RX DISASSEMBLY PREP 1 IC 0.075 1.60 ROUTINE CRANE OPERATIONS 841008 010056 D20A001 RX DISASSEMBLY PREP 3 IC J.326 8.17 ROUTINE CRANE OPERATIONS 841019 010129 D20A001 RX DISASSEMBLY PREP 1 EL 0.104 2.37 ROUTINE CRANE OPERATIONS
  • 841019 010129 D20A001 RX DISASSEMBLY PREP 2 IC 0.159 3.91 ROUTINE CRANE OPERATIONS 841024 010162 D20A001 RX DISASSEMBLY PREP 3 EL 0.222 9,27 ROUTINE CRANE OPERATIONS
  • 841024 010162 D20A001 RX DISASSEMBLY PREP 11 IC 1.087 34.56 ROUTINE CRANE OPERATIONS

DATE 022186 PAGE 4 PNO. 3 .TMI-2 UNC-DOS - ACTIVITY REPORT - RE ACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP 'RCK. PERS. DEPT EXPOS. RWP.,...............-................I.ON AC ENTRG. CODE R TASK DESCRIPT

  • DATE... NUMBER. NUMB.E.R......... T I. V I. T Y

.......,......,......,...E.M..,. HOUR S..

  • .es.

841031 010203 D20A001 RX DISASSEMBLY PREP 9 EL 0.693 26.40 ROUTINE CRANE OPERt.TIONS

  • 841031 010203 D20A001 RX DISASSEMBLY PREP 1 CN 0.050 3 03 ROUTINE CRANE OPERATIONS
  • 841031 010203 D20A001 RX DISASSEMBLY PREP 6 IC 0.495 18.05 ROUTINE CRANE OPERATIONS 841107 010247 D20A001 RX DISASSEMBLY PREP 7 EL 0.734 19 24 ROUTINE CRANE OPERATIONS
  • 841107 010247 D20A001 RX DISASSEMBLY PREP 2 CN 0.000 4.93 ROUTINE CRANE OPERATIONS
  • 841107 010247 D20A001 RX DISASSEMBLY PREP 2 IC 0.157 5.13 ROUTINE CRANE OPERATIONS
  • 841107 010247 D20A001 RX DISASSEMBLY PREP 2 UM 0.000 2.33 ROUTINE CRANE OPERATIONS 841114 010292 D20A001 RX DISASSEMBLY PREP 6 IC 0.526 12.60 ROUTINE CRANE OPEPATIONS
  • 841114 010292 D20A001 RX DISASSEMBLY PREP 1 EL 0.100 3.35 ROUTINE CRANE OPERATIONS 841121 010334 D20A001 RX DISASSEMBLY PREP 1 IC 0.116 2.43 ROUTINE CRANE OPERATIONS 841128 010361 D20A001 RX DISASSEMBLY PREP 11 IC 0.8J7 29.02 ROUTINE CRANE OPERATIONS 841205 010413 D20A001 RX DISASSEMBLY PREP 8 IC 0.613 24.28 ROUTINE CRANE OPERATIONS
  • 841205 010413 020A001 RX DISASSEMBLY PREP 4 EL 0.319 11.35 ROUTINE CRANE OPERATIONS
  • 841205 010413 D20A001 RX DISASSEMBLY PREP 2 MM 0.116 3.37 ROUTINE CRANE OPERATIONS 841212 010460 020A001 RX DISASSEMBLY PREP 8 IC 0.712 22.08 ROUTINE CRANE OPERATIONS
  • 841212 010460 020A001 RX DISASSEMBLY PREP 2 MM 0.187 6.42 ROUTINE CRANE OPERATIONS
  • 841212 010460 D20A001 RX DISASSEM8LY PREP 3 EL 0.247 8.97 ROUTINE CRANE OPERATIONS 841219 010514 D20A001 RX DISASSEMBLY PREP 2 EL 0.189 5.92 ROUTINE CRANE OPERATIONS
  • 841219 010514 D20A001 RX DISASSEMBLY PREP 3 IC 0.316 9.81 ROUTINE CRANE OPERATIONS
  • 841219 010514 D20A001 RX DISASSEMBLY PREP 2 MM 0,125 5.37 ROUTINE CRANE OPERATIONS 841226 010549 D20A001 RX DISASSEMBLY PREP 1 MM 0.079 2.02 ROUTINE CRANE OPERATIONS 850103 010597 D20A001 RX DISASSEMBLY PREP 2 MM 0.126 2.82 ROUTINE CRANE OPERATIONS
  • 850103 010597 D20A001 RX DISASSEMBLY PREP 1 EL 0.026 0,76 ROUTINE CRANE OPERATIONS
  • 850103 010597 020A001 RX DISASSEMBLY PREP 1 IC 0,099 3.17 ROUTINE CRANE OPERATIONS I

850110 010640 D20An01 RX DISASSEMBLY PREP 1 EL 0.140 2.68 ROUTINE CRANE OPERATIONS

    • *850110 010640 D20A001 RX DISASSEMBLY PREP 1 IC 0.029 0.82 ROUTINE CRANE OPERATIONS Ch 850116 010689 D20A001 RX DISASSEMBLY PREP 1 MM 0.178 3.32 ROUTINE CRANE OPERATIONS
  • 850116 010689 D20A001 RX DISASSEMBLY PREP 2 IC 0.226 5.53 ROUTINE CRANE OPERATIONS
  • 850116 010689 D20A001 RX DISASSEMBLY PREP 1 EL 0.167 3.70 ROUTINE CRANE OPERATIONS 850123 010737 020A001 RX DISASSEMBLY PREP 1 EL 0.026 0.72 ROUTINE CRANE OPERATIONS 850208 010842 D20A001 RX DISASSEMBLY PREP 1 EL 0.147 3.62 ROUTINE CRANE OPERATIONS
  • 850208 010842 D20A001 RX DISASSEMBLY PREP 3 IC 0.180 4.32 ROUTINE CRANE OPERATIONS
  • 850208 010842 D20A001 RX DISASSEMBLY PREP 1 MM 0.116 2 87 ROUTINE CRANE OPERATIONS 850215 010898 D20A001 RX DISASSEMBLY PREP 1 MM 0,168 3.33 ROUTINE CRANE OPERATIONS 850219 010907 D20A001 RX DISASSEMBLY PREP 4 IC 0.294 11.50 ROUTINE CRANE OPERATIONS
  • 850219 010907 D20A001 RX DISASSEMBLY PREP 2 MM 0.127 5.13 ROUTINE CRANE OPERATIONS
  • 850219 010907 D20A001 RX DISASSEMBLY PREP 3 EL 0.230 7.73 ROUTINE CRANE OPERATIONS 850225 010959 D20A001 RX DISASSEMBLY PREP 4 EL 0.259 9.77 ROUTINE CRANE OPERATIONS
  • 850225 010959 D20A001 RX DISASSEMBLY PREP 7 MM 0.627 19.83 ROUTINE CRANE OPERATIONS
  • 850225 010959 D20A001 RX DISASSEMBLY PREP 5 IC 0.454 14.27 ROUTINE CRANE OPERATIONS 850304 011030 D20A001 RX DISASSEMBLY PREP 2 EL 0.147 4,88 ROUTINE CRANE'0PERATIONS
  • 850304 011030 D20A001 RX DISASSEMBLY PREP 3 MM 0.274 8.40 ROUTINE CRANE OPERATIONS
  • 850304 011030 D20A001 RX DISASSEMBLY PREP 2 IC 0.145 4.18 ROUTINE CRANE OPERATIONS 850311 011081 D20A001 RX DISASSEMBLY PREP 5 EL 0.453 13.18 ROUTINE CRANE C ERATIONS
  • 850311 011081 D20A001 RX DISASSEMBLY PREP 8 MM 0.889 18.88 ROUTINE CRANE OPERATIONS
  • 850311 011081 D20A001 RX DISASSEMBLY PREP 4 IC 0.465 11.27 ROUTINE CRANE OPERATIONS 850318 011147 D20A001 RX DISASSEMBLY PREP 4 EL 0.494 12.00 ROUTINE CRANE OPERATIONS
  • 850318 011147 D20A001 RX DISASSEMBLY PREP 5 IC 0.668 15.32 ROUTINE CRANE OPERATIONS
  • 850318 011147 D20A001 RX DISASSEMBLY PREP 6 MM 0.423 10.78 ROUTINE CRANE OPERATIONS 850325 011197 D20A001 RX DISASSEMBLY PREP 4 EL 0.273 7.37 ROUTINE CRANE OPERATIONS

DATE 022186 PAGE 5 PNO. 4 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP,

  • D. A T E... NU.MBE.R........UMB.E.R

........C. T I V I T. Y .. E. N T RG. CODE..,.. R E M....URS.............................E.SCRIPTI.ON N A HO TASK D .......... 0.293 8.07 ROUTINE CRANE OPERATIONS

  • 850325 011197 D20A001 RX DISASSEMBLY PREP 4 MM
  • 850325 011197 D20A001 RX DISASSE.MBLY PREP 4 IC 0.354 9.78 ROUTINE CRANE OPERATIONS

. SUBTOTAL - EXP-TRCK NUMBER D20A001 PERS ENTRG. 527 EXPOS REM 50.951000 RWP HOURS s 1160.8800* .830712 006938 D20E001 RD&D SUPP-0UTS CTMT 4 RP 0 000 3.36 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX

  • 830712 006938 D20E001 RD&D SUFP-0UTS CTMT 1 EL 0.005 2.90 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX
  • 830712 006938 D20E001 RD&D SUPP-0UTS CTMT 1 UM 0.005 2.90 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX
  • 830712 006938 D20E001 RD&D SUPP-0UTS CTMT 1 MM 0.000 2.90 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX
  • 830712 006938 D20E001 RD&D SUPi-0UTS CTMT 2 CN 0.000 1.73 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX
  • 830712 006938 D20E001 RD&D SUPP-0UTS CTMT 1 RC 0.005 3.63 MOVE HIGH RAD TRASH-ANTEROOM TO 305 AUX 830723 007031 D20E001 RD&D SUPP-0UTS CTMT 1 HP 0.043 1.03 VALVE LINE-UP
  • 830723 007031 D20E001 RD&D SUPP-0UTS CTMT 1 OP 0.035 1.05 VALVE LINE-UP 830807 007151 D20E001 RD&D SUPP-0UTS CTMT 4 IC 0.000 5,93 MARK CABLE AND TEST 830812 007212 D20E001 RD&D SUPP-0UTS CTMT 1 HP 0.000 1.67 DECON CAMERAS AND TRANSFER TO HOT 0?OP
  • 830812 007212 D20E001 RD&D SUPP-0UTS CTMT 3 IC 0.000 8.36 OECON CAMERAS AND TRANSFER TO HOT SHOP
  • 830812 007212 D20E001 RD&D SUPP-0UTS CTMT 1 RP 0.000 1.10 DECON CAMERAS AND TRANSFER TO HOT SHOP 830815 007239 D20E001 RD&D SUPP-0UTS CTMT 2 IC 0.000 2.98 DATA ACQUISITION-WEST TV CAMERA 830818 007257 D20E001 RD&D SUPP-0UTS CTMT 2 CN 0.006 13.53 ASSESMBLE URANIUM F0lls 830920 007529 D20E001 RD&D SUPP-0UTS CTMT 1 CM 0.000 0.08 MOVE PENDANT TO FHB 305/ REPAIR COMPACTOR
  • 830920 007529 D20E001 RD&D SUPP-0UTS CTMT 5 CN 0.002 6.20 MOVE PENDANT TO FHB 305/ REPAIR COMPACTOR 840510 008983 D20E001 RD&D SUPP-0UTS CTMT 1 HP 0.000 5.12 NEUTRON ACTIVATION EXPERIMENT
  • 840510 008982 D20E001 RD&D SUPP-OUTS CTMT 1 OP 0.000 0.30 NEUTRON ACTIVATION E XPE RIME NT
  • 840510 008983 D20E001 RD&D SUPP-0UTS CTMT 1 CN 0.000 5.00 NEUTRON ACTIVATION EXFERIMENT 840510 008983 D20E001 RD&D SUPP-0UTS CTMT I EG 0.002 4.92 NEUTRON ACTIVATION EXPERIMENT d,)*840516009020D20E001 RD&D SUPP-0UTS CTMT 1 HP 0.000 2.07 NEUTRON ACTIVATION EXPERIMENT
  • 840516 009020 D20E001 RD&D SUPP-0UTS CTMT 1 EG 0.002 7.47 NEUTRON ACTIVATION EXPE RIMENT
  • 840516 009020 D20E001 RD&D SUPP-0UTS CTMT 2 CN 0.000 8.01 NEUTRON ACTIVATION EXPERIMENT 840714 009459 D20E001 RD&D SUPP-0UTS CTMT 1 IC 0.002 1.18 CALIBRATE E.P.

TRANSMITTER 840723 009540 D20E001 RD&D SUPP-0UTS CTMT' 9 CN 0.029 39,53 FLUSH DRAIN /TAKE SAMPLE . SUBTOTAL - EXP-TRCK NUMBER = D20E001 PERS ENTRG = 49 EXPOS REM. HOURS 0.1060000 RWP 132.95000 .840907 009856 D20E002 GANTRY CRANE 4 CN 0.844 7.12 INSTALL TERMINALS / CHECK GANTRY ELECTRIC 840907 009857 D20E002 GANTRY CRANE 11 CN 2.452 24.48 GANTRY CRANE INSTALLATION . SUBTOTAL - EXP-TRCK NUMBER = D20E002 PERS ENTRG = 15 EXPOS REM 3.2960000 = RWP HOURS 31.600000 .830524 006586 020F001 FUEL CANAL MODS. 2 CN 0.013 1.82 DRILL HANGER. RUN HOSE-SFP2 TO PENET 565 830608 006677 D20F001 FUEL CANAL MODS. 3 CN 0.000 2.95 RUN HOSE TO PENET 565. BOLT UP FLANGE 830901 007377 D20F001 FUEL CANAL MODS. 2 CN 0.449 4.27 VIDEO SURVEY OF VALVE SF-V-104 840116 008269 D20F001 FUEL CANAL MODS. 3 CN 0.381 11.23 TEST SF-V-102 & CUT REFUELING CANAL PIPE 840123 008311 D20F001 FUEL CANAL MODS. 4 CN 0.375 8 52 CUT INSUL RACK BASES WITH PLASMA ARC 840206 008402 D20F001 FUE L CANAL MODS. 3 CN 0.493 9.70 CUT INSUL RACK BASES / REPLACE BOTTLES

  • 840206 008402 D20F001 FUEL CANAL MODS.

1 EL 0.150 3.00 CUT INSUL RACK BASES / REPLACE BOTTLES 840208 008420 D20F001 FUEL CANAL MODS. 3 CN 0.095 2.22 INSTALL POWER FOR CANAL DRAIN PUMP 840210 008431 020F001 FUEL CANAL MODS. 2 CN 0.065 2.20 INSTALL POWER FOR CANAL DRAIN PUMP

_ _ _ _ _ _ _ = _ _ _ _ _ _ _ _ .CATE 022186 PAGE 6 PNO. .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS, DEPT EXPOS. RWP. TAS

  • DATE..NUMBE.R.......ER............CTIVIT.Y................ENTRG. CO.DE......EM......OURS.............................K.. DES.CRIPTION NUMB A

R . H s..... 840321 008677 D20F001 FUE L CANAL-MODS. 2 CN 0.140 2.27 ADDITIONAL LIGHTING - REFUELING CANAL 840423 008864 020F001 FUEL CANAL MODS. 2 CN 0.196 2.62 AS-BUILT DIMENSION ON UP-ENDER TOOLS 840426 008897 D20F001 FUEL CANAL MODS. 8 CN 1.899 23.02 INSTALL CANAL SEAL PLATE PLATFORM 840430 008911 D20F001 FUEL CANAL MODS. 6 CN 0.440 11.35 INSTALL CANAL SEAL PLATE PLATFORM 840623 009282 D20F001 FUEL CANAL MODS. 5 CN 0.620 9.78 PROVIDE CANAL AREA LIGHTING 840623 009284 D20F001 FUEL CANAL MODS. 14 CN 1.448 25.88 INSTALL FUEL XFER POOL DRAIN MANIFOLD 840628 009332 D20F001 FUE L CANAL MODS. 3 CN 0.162 3.46 INSTALL FUEL XFER CANAL DRAIN PUMP $840628 009332 D20F001 FUEL CANAL MODS. 1 CA 0.081 1.12 INSTALL FUEL XFER CANAL DRAIN PUMP 840630 009346 D20F001 FUEL CANAL MODS. 3 CN 0.211 5.78 GRIND WELD IN REFUEL CANAL DRAINPIPE 840713 009448 D20F001 FUEL CANAL MODS. 3 CN 0.132 4.00 CANAL DRAIN PUMP LEAK TEST

  • 840713 009448 D20F001 FUEL CANAL MODS.

1 QA 0.059 1.17 CANAL DRAIN PUMP LEAK TEST 840718 009490 D20F001 FUEL CANAL MODS. 5 CN 0.430 12.48 INSTALL FUEL TRANSFER CANAL DRAIN PUMP 840718 009490 D20F001 FUEL CANAL MODS. 1 CA 0.036 1.12 INSTALL FUEL TRANSFER CANAL DRAIN PUMP 840718 009493 D20F001 FUEL CANAL MODS. 2 CN 0.155 4.23 INSTALL POWER TO NEW DRAIN PUMP 840721 009513 D20F001 FUEL CANAL MODS. 4 CN 0.430 9.45 INSTL 4 IN. PUMP IN FUEL XFER CANAL FLOOR 841107 010244 D20F001 FUEL CANAL MODS. 4 CN 0.228 7.05 WELD INSPECTION-TRANSFER CANAL DEEP END . SUBTOTAL - EXP-TRCK NUMBER = D20F001 PERS ENTRG = 87 EXPOS REM 8.6880000 RWP NOURS. 170.69000 l ..850123 010735 D20F004 RB SERVICE CRANE 12 CN 1.662 34.03 CHECK FOR INTERFERENCE-D RING GANTRY i 850130 010776 D20F004 RB SERVICE CRANE 3 CN 0.540 8.05 WALKDOWN RX BUILDING SERVICE CRANE . SUBTOTAL - EXP-TRCK NUMBER = D20F004 PERS ENTRG.- 15 j, EXPOS HOURS. 2.2020000 REM 42.080000 RWP 00.841217 010484 020H001 DEFUELING WORK PLTFM 8 CN 0.759 21.12 AS-BUILT REFUELING CANAL SHALLOW END e 850117 010677 D20H001 DEFUELING WORK PLTFM 8 CN 0.448 16.30 CUT HOLES IN SEAL PLATE WORK PLATFORM 850201 010789 D20H001 DEFUELING WORK PLTFM 2 IC 0.147 3.73 ROUTINE CRANE OPERATIONS

  • 850201 010789 D20H001 DEFUELING WORK PLTFM 2 MM 0.244 4.75 ROUTINE CRANE OPERATIONS
  • 850201 010789 D20H001 DEFUELING WORK PLTFM 1 EL 0.070 0.97 ROUTINE CRANE OPERATIONS 850204 010799 D20H001 DEFUELING WORK PLTFM 12 CN 0.492 16.50 CUT HOLES IN SEAL PLATE WORK PLATFORM 850205 010820 D20H001 DEFUELING WORK PLTFM 3 CN.

0.275 7.90 AS-BUILT REFUELING CANAL SHALLOW END . SUBTOTAL - EXP-TRCK NUMBER D20H001 PERS ENTRG. '36 HOURS. 2.4350000 EXPOS REM. 71.270000 RWP .830127 005669 D22E001 NEUTRON SHIELD TANKS 2 OP 0.336 3.15 REMOVE NEUTRON SHIELDS

  • 830127 005669 D22E001 NEUTRON SHIELD TANKS 2 CM 0.335 5.05 REMOVE NEUTRON SHIELDS
  • 830127 005669 D22E001 NEUTRON SHIELD TANKS 2 HP 0.330 4.37 REMOVE NEUTRON SHIELDS
  • 830127 005669 D22E001 NEUTRON SHIELD TANKS 1 RP 0.150 1.58 REMOVE NEUTRON SHIELDS
  • 8S0127 005669 D22E001 NEUTRON SHIELD TANKS 3 MM 0.627 7.00 REMOVE NEUTRON SHIELDS 830215 005834 D22E001 NEUTRON SHIELD TANKS 8 CN 1.041 16.20 REMOVE NEUTRON SHIELD TANKS FROM CTMT.

830308 006011 D22E001 NEUTRON SHIELD TANKS S CN 0.915 9.43 INSTALL REMOVABLE BEAM AND GRATING 830315 006057 D22E001 NEUTRON SHIELD TANKS 17 CN 3.103 35.27 CLEAN HEADLIFT PINS 830317 006074 D22E001 NEUTRON SHIELD TANKS 1 IC 0.169 1.28 TROUBLESHOOT / REPAIR SOURCE RANGE INST. 830524 006580 022E001 NEUTRON SHIELD TANKS 2 CN 0.246 3.67 AS-BUILT GANTRY CRANE RAIL BOLTS 830726 007060 D22E001 NEUTRON SHIELD TANKS 4 CN 0.420 6.73 REMOVE NEUT SHIELD TKS FROM REFUEL CANAL

  • 830726 007060 D22E001 NEUTRON SHIELD TANKS 1 EL 0.110 1.77 REMOVE NEUT SHIELD TMS FROM REFUEL CANAL 830729 007080 D22E001 NEUTRON SHIELD TANKS 4 CN 0.513 7.81 CUT NEUT SHIELD TKS-SHALLOW END OF CANAL

_m.... _...., _ _. t DATE 022186 PAGE 7 PNO. 6 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 0 . RWP .EXP-TRCK, PERS. DEPT EXPOS. RWP. .............. T. A S. K D. E. S.C R I P. T.I O N............,,

  • DAT. E... NU.MBE. R...... B. E. R.......... C..T.I V I.T Y................ E. N. T R. G.. C. OD E..,.. R E.M NUM A

......S........ HOUR

  • 830729 007080 D22E001 NEUTRON SHIELD TANKS 1 EL 0.082 1.52 CUT NEUT SHIELD TKS-SHALLOW END OF CANAL 830801 007092 D22E001 NEUTRON SHIELD TANKS 11 CN 1.110 17.33 RIG AND CUT NEUTRON SHIELD TANKS
  • 830801 007092 D22EOO1 NEUTRON SHIELD TANKS 1 EL 0.079 1.65 RIG AND CUT NEUTRON SHIELD TANKS 830808 007145 D22E001 NEUTRON SHIELD TANKS 14 CN 1.210 22.75 CUT AND REMOVE NEUTRON SHIELD TANKS
  • 830808 007145 D22E001 NEUTRON SHIELD TANKS 2 EL 0.198 3.70 CUT AND REMOVE NEUTRON SHIELD TANKS 830815 007215 D22E001 NEUTRON SHIELD TANKS 1 MM 0.089 1.73 REMOVE NEUTRON SHIELD TANKS
  • 830815 007215 D22E001 NEUTRON SH.IELD TANKS 3 CN 0.356 5.15 REMOVE NEUTRON SHIELD TANKS

. SUBTOTAL - EXP-TRCK NUMBER 022E001 PERS ENTRG. 85 EXPOS REM 11.419000 RWP HOURS. 157.14000 5 .830217 005854 022E002 RX HEAD INSULATION 3 MM 0.527 5.73 REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL . *830217 005854 D22E002 RX HEAD INSULATION 2 OP 0.277 3.05-REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL l

  • 830217 005854 D22E002 RX HEAD INSULATION 2 RP 0.416 3.73 REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL
  • 830217 005854 D22E002 RX HEAD INSULATION 1 CM 0.170 2.17 REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL s
  • 830217 005854 D22E002 RX HEAD INSULATION 2 HP 0.274 4.83 REMOVE RX HEAD THER INSUL/ MOVE TO 305 EL 830819 007262 D22E002 RX HEAD INSULATION 1 EL 0.112 1.53 CUT MIRROR INSULATION 7
  • 830819 007262 D22E002 RX HEAD INSULATION 4 CN 0.429 6.12 CUT MIRROR INSULATION 830823 007303 D22E002 RX HEAD INSULATION 1 MM 0.154 2.33 CUT MIRROR INSULATION 5
  • 830823 007303 D22E002 RX HEAD INSULATION 4 CN 0.597 8.97 CUT MIRROR INSULATION 830826 007319 D22E002 RX HEAD INSULATION 3 CN 0.556 5.73 CUT MIRROR INSULATION 830902 007379 D22E002 RX HEAD INSULATION 4 CN 0.774 10.25 CUT MIRROR INSULATION 830906 007396 D22E002 RX HEAD INSULATION 8 CN 1.253 15.80 CUT MIRROR INSULATION L

830908 007424 D22E002 RX HEAD INSULATION 2 CN 0.174 2.50 CUT AND RIG MIRPOR INSULATION 830912 007450 D22E002 RX HEAD INSULATION 1 MM 0.107 1.92 RIG MIRROR INSULAT10N.347' TO 305' ELEV 8

  • 830912 007450 022E002 RX HEAD INSULATION 2 EL 0.197 3.67 RIG MIRROR INSULATION-347' TO 305' ELEV s

45 830919 007499 D22E002 RX HEAD INSULATION 2 OP 0.092 1.77 SET UP CUTTING AREA / CLEAN BANDSAW AREA W3

  • 830919 007499 022E002 RX HEAD INSULATION 2 IC 0,127 1.82 SET UP CUTTING AREA / CLEAN BANDSAW AREA 8

830920 007523 022E002 RX HEAD INSULATION 1 MM 0.160 2.72 CUT MIRROR INSULATION RACKS WITH BANDSAW

  • 830920 007523 D22E002 RX HEAD INSULATION 13 CN 1.303 22.50 CUT MIRROR INSULATION RACKS WITH BANDSAW i

831219 008117 D22E002 RX HEAD INSULATION 1 MM 0.094 1.58 CUT MIRROR INSUL RACK BASE-PLASMA ARC

  • 831219 008117 D22E002 RX HEAD INSULATION 4 CN 0.325 6.64 CUT MIRROR INSUL RACK BASE-PLASMA ARC 840201 008375 D22E002 RX HEAD INSULATION 3 CN 0.320 6.37 CUT MIRROR INSULATION RACK BASES

. SUBTOTAL - EXP-TRCK NUMBER 022E002 PERS ENTRG = 66 EXPOS HOURS. 8.4380000 REM. RWP 121.73000 .830323 006124 D22E003 RV STUD REMCVAL 2 MM 0.195 1.97 LUBE STUD THREADS ON RV HEAD y 830513 006495 D22E003 RV STUD REMOVAL 1 MM 0,071 1.42 LUBE STUDS ON RV HEAD AND INTERFACE 840210 008427 D22E003 RV STUD REMOVAL 4 CN 0.671 9.60 STAGE STUD CLEANING TOOLS

  • 840210 008427 D22E003 RV STUD REMOVAL 1 MM 0.155 2.57 STAGE STUD CLEANING TOOLS 840307 008580 D22E003 RV STUD REMOVAL 3 MM 0.844 8.70 CLEAN RX HEAD STUDS MECHANICALLY
  • 840307 008580 D22E003 RV STUD REMOVAL 1 EC 0.300 2.93 CLEAN RX HEAD STUDS MECHANICALLY
  • 840307 008580 D22E003 RV STUD REMOVAL 3 UM 0.890 8.62 CLEAN RX HEAD STUDS MECHANICALLY
  • 840307 008580 D22E003 RV STUD REMOVAL 1 CN 0.300 3.32 CLEAN RX HEAD STUDS MECHANICALLY
  • 840307 008580 D22E003 RV STUD REMOVAL 1 MD 0.300 3.32 CLEAN RX HEAD STUDS MECHANICALLY 840308 008589 D22E003 kV STUD REMOVAL 3 MM 0.580 6.66 MECHANICAL CLEANING OF HEAD STUDS
  • 840308 008589 D22E003 RV STUD REMOVAL 1 CN 0.250 2.32 MECHANICAL CLEANING OF HEAD STUDS 840319 008647 D22E003 RV STUD REMOVAL 4 CN 0.587 8.69 MEASURE IIF BUSHING
  • 840319 008647 D22E003 RV STUD REMOVAL 1 EL 0.054 1.48 MEASURE IIF BUSHING i

~ 1

_.... _. _ m _ _ _ _ _ m_ l l l r i DATE 022186 PAGE 8 i PNO. -7 .TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT

EXPOS, RWP,

.............. T. A S. K.D. E.SC R I P T..I O.N I ......S.

  • D ATE... NUMB.E.R........E.R......... C. T I. V I T. Y.........,.......ENTRG.. C. ODE.......E.M HOUR NUMB A

R... 840627,009321 022E003 RV STUD REMOVAL 22 MM 2.610 50.52. RV STUD DETENSIONING

  • 840627 009321 D22E003 RV STUD REMOVAL 11 UM 1.384 24,47 RV STUD DETENSIONING
  • 840627 009321 D22E003 RV STUD REMOVAL 2 EL 0.228 4.55 RV STUD DETENSIONING j

840702 009151 D22E003 RV STUD REMOVAL 21 MM 2.717 50.05-REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS i

  • 840702 009351 D22E003 RV STUD REMOVAL 16 UM 2.267 37.87 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS l

2840702 009351 D22EOO3 RV STUD REMOVAL 2 CM 0.321 5.25 REMOVE RV STUD 3/ INSTALL INHIBITOR & PLUGS

  • 840702 009351 022E003 'RV STUD REMOVAL 2 EL 0.288 4.97 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS

{ 840702 009352 D22E003 RV STUD REMOVAL 4 CN 0.311 4.90 RIG STUD DETENSIONERS TO 305' LEVEL 1 840702 009356 022E003 RV STUD REMOVAL 10 CN 1.456 20.98 MOVE 5 STUD STORAGE RACKS INTO CTMT I 840703 009373 D22E003 RV STUD REMOVAL 10 CN 0.886 18.87 MOVE AND STAGE STUD STORAGE RACKS i 840707 009395 D22E003 RV STUD REMOVAL 2 MM 0.130 2.15 REMOVE RV STUDS / INSTALL INHIBITOR 1 PLUGS

  • 840707 009395 D22E003 RV STUD REMOVAL 3 UM 0.216 3.28 REMOVE RV STUDS / INSTALL INHIBITOR & PLUGS 840710 009418 022E003 RV STUD REMOVAL 5 CN 0.366 8.32 MOVE STUD STORAGE RACKS TO 347' LEVEL 840917 009916 D22E003 RV STUD REMOVAL 3 CN 0.479 3.73 REMOVE STUD TENSIONERS FROM RB 841113 010270 D22E003 RV STUD REMOVAL 22 CN 2.259 47.80 STAGE RX HEAD STUDS IN HEAD FLANGE 841227 010558 D22E003 RV STUD REMOVAL 2 CN 0,113 1.72 REMOVE ONE HALF OF STUD STORAGE RACK

.r . SUBTOTAL - EXP-TRCK NUMBER = D22E003 l PERS ENTRG. 163 EXPOS REM = 21.228000 RWP HOURS = 351.03000 .830211 005802 D22E004 CANAL SEAL PLATE 3 CN 0.G98 8.05 INSPECT CANAL SHIELD PLATE / SEAL LEDGE

  • 830211 005802 D22E004 CANAL SEAL PLATE 1 HP 0.070 1.37 INSPECT CANAL SHIELD PLATE / SEAL LEDGE 830421 006316 D22E004 CANAL SEAL PLATE 2 CN 0.261 6.33 INSPECT TRANSPORT TUBE &NEUT SHLD TK SUPP 830427 006357 D22E004 CANAL SEAL PLATE 2 CN 0.242 2.62 MOVE NEUTRON SHIELD TANKS 830701 006850 D22E004 CANAL SEAL PLATE 2 CN 0.289 2.68 MEASURE CANAL SEAL PLATE LEDGE
  • 830701 006850 D22E004 CANAL SEAL PLATE 1 HP C.156 1.62 MEASURE CANAL SEAL PLATE LEDGE an C) - 830819 007265 D22E004 CANAL SEAL PLATE 1 CN 0.050 0.65 INSPECT SEAL LEDGE FOR CLEANING REQMTS e

.830826 007321 022E004 CANAL SEAL PLATE 7 CN 0.955 13.36 RIG SEAL PLATE TO 322'/ PREP FOR DRILLING

  • 830826 007321 022E004 CANAL SEAL PLATE 1 EL 0.126 2.12 RIG SEAL PLATE TD 322*/ PREP FOR DRILLING 830826 007323 D22E004 ' CANAL SEAL PLATE 1 RW 0.202 1.85 PREPARE AND CLEAN SEAL PLATE
  • 830826 007323 D22E004 CANAL SEAL PLATE 1 UM 0.141 1.93 PREPARE AND CLEAN SEAL PLATE j

830826 007324 D22E004 CANAL SEAL PLATE 1 RP ' O.064 1.23 PREPARE SEAL. PLATE LAY-DOWN AREA

  • 830826 007324 D22E004 CANAL SEAL PLATE 1 OP 0.019 1.30 PREPARE SEAL PLATE LAY-DOWN AREA 840116 008267 D22E004 CANAL SEAL PLATE 1 QA 0.100 1.37 INSPECT / MEASURE CANAL SEAL PLATE i
  • 840116 008267 D22E004 CANAL SEAL PLATE 1 CN 0.240 3.72 INSPECT / MEASURE CANAL SEAL PLATE 840116 008268 022E004 CANAL SEAL PLATE 6 CN 1.236 18.65 TRIAL FIT CANAL SEAL PLATE 840123 008305 D22E004 CANAL SEAL PLATE 2 IC 0.132 2.73 REMOVE NI COVER PLATE GASKETS 840123 008312 D22E004 CANAL SEAL PLATE 1 CA 0.100 1.95 INSPECT / MEASURE CANAL SEAL PLATE
  • 840123 008312 D22E004 CANAL SEAL PLATE 1 CN 0.150 3.73 INSPECT / MEASURE CANAL SEAL PLATE i

840123 008313 D22E004 CANAL SEA *. PLATE 6 CN 0.798 14.00 TRIAL. FIT CANAL SEAL PLATE

  • 840123 008313 D22E004 CANAL SEAL PLATE 1 MM 0.083 1.52 TRIAL FIT CANAL SEAL PLATE 840404 008760 022E004 CANAL SEAL PLATE 1 OP 0.205 1.58 CLEAN CANAL SEAL LEDGE

}

  • 840404 008760 D22E004 CANAL SEAL PLATE 1 IC 0.190 1.53 CLEAN CANAL SEAL LEDGE
  • 840404 008760 D22E004 CANAL SEAL PLATE 1 CM 0.130 1.65 CLEAN CANAL SEAL LEDGE
  • 840404 008760 D22E004 CANAL SEAL PLATE 1 UM 0.243 1.53 CLEAN CANAL SEAL LEDGE
  • 840404 008760 D22E004 CANAL SEAL PLATE 1 MM 0.161 1.72 CLEAN CANAL SEAL LEDGE
  • 840404 008760 022E004 CANAL SEAL PLATE 2 CN 0.206 3.15 CLEAN CANAL SEAL LEDGE i

840406 008770 D22E004 CANAL SEAL PLATE 2 OP 0.175 3.45 CLEAN CANAL SEAL PLATE AND CANAL

  • 840406 008770 D22E004 CANAL SEAL PLATE 1 IC 0.079 1.75 CLEAN CANAL SEAL PLATE AND CANAL
  • 840406 008770 D22E004 CANAL SEAL PLATE 1 MM 0.113 1.72 CLEAN CANAL SEAL PLATE AND CANAL

( i I l , = _

DATE 022186 PAGE 9 PNO. 8 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCh. PERS DEPT EXPOS. RWP.

  • D. A T E... N UMB. E R.......E.R

.........TIVIT.Y......................G.. CODE....RE.M... O. U R S. NUMB AC ENTR H .....D. E. SC R I P T I O N .............. TASK 1 CN . 0.100 1.68 CLEAN CANAL SEAL PLATE AND CANAL

  • 840406 008770 D22E004 CANAL SEAL PLATE 840409 008783 D22E004 CANAL SEAL PLATE 6 CN 0.894 14.82 STAGE EQUIP F OR SEAL PLATE INSTALLATION 840412 008809 D22E004 CANAL SEAL PLATE 1 EL 0.200 1.93 CLEAN CANAL SEAL LEDGE AND CANAL
  • 840412 008809 D22E004 CANAL SEAL PLATE 2 CM 0.357 4,85 CLEAN CANAL SEAL LEDGE AND CANAL
  • 840412 008809 D22E004 CANAL SEAL PLATE 1 OP 0.218 2.38 CLEAN CANAL SEAL LEDGE AND CANAL
  • 840412 008809 D22E004 CANAL SEAL PLATE 1 CN 0.194 2.43 CLEAN CANAL SEAL LEDGE AND CANAL 840413 008815 D22E004 CANAL SEAL PLATE 1 CA 0.135 2.50 INSTALL SEAL PLATE GASKETS / CLEANING
  • 840413 008815 D22E004 CANAL SEAL PLATE 7 CN 1.398 17.87 INSTALL SEAL PLATE GASKETS / CLEANING 840416 008525 D22E004 CANAL SEAL PLATE 24 CN 3.186 63.08 RIG SEAL PLATE INTO ANNULUS
  • 840416 008525 D22E004 CANAL SEAL PLATE 3 OA 0.260 5.35 RIG SEAL PLATE INTO ANNULUS 840417 008842 022E004 CANAL SEAL PLATE 4 IC 0.360 6.70 REMOVE NI COVER PLATES 840423 008863 022E004 CANAL SEAL PLATE 8 CN 0.821 18.08 FINAL SEAL PLATE CLEANUP /RTV SEAL 840425 008890 D22E004 CANAL SEAL PLATE 4 CN 0.343 8.10 REMOVE AND CUT ANNULUS COVERS AND SUPPS.

. SUBTOTAL - EXP-TRCK NUMBER = D22E004 PERS ENTRG. 117 EXPOS REM. 16.140000 RWP HOURS. 261.23000 . 830524 006581 022E005 CRDM REMOVAL 2 RP 0.103 2.37 GENERAL ACTIVITY WORK PACKAGE 840409 008780 D22E005 CRDM REMOVAL 4 EL 0.491 9.93 REMOVE STATORS FROM RVHSS

  • 840409 008780 D22E005 CRDM REMOVAL 1 CN 0.135 2.62 REMOVE STATORS FROM RVHSS 840622 009269 D22E005 CRDM REMOVAL 2 CN 0.140 2.72 CRDM TOP CLOSURE / STAGE BULLARD
  • 840622 009269 D22E005 CRDM REMOVAL 1 UM 0.050 1.00 CRDM TOP CLOSURE / STAGE BULLARD
  • 840622 009269 D22E005 CRDM REMOVAL 2 MM 0.109 2.23 CRDM TOP CLOSURE / STAGE BULLARD
  • 840622 009269 D22E005 CRDM REMOVAL 1 CM 0.050 1 28 CRDM TOP CLOSURE / STAGE BULLARD I

840628 009331 D22E005 CRDM REMOVAL 3 UM 0.248 4.85 CRDM TOP CLOSURE REMOVAL U1 850206 010829 D22E005 CRDM REMOVAL 3 CN 0.258 6.88 REMOVE LDSCR SUPPORT TUBE & CRDM ~ "" *850206 010829 022E005 CRDM REMOV.AL 1 HP 0.065 2.25 REMOVE LDSCR SUPPORT TUBE & CRDM 8 . SUBTOTAL - EXP-TRCK NUMBER D22E005 PERS ENTRG. 20 EXPOS REM 1.6490000 = RWP HOURS. 36.130000 . 840116 008262 D22E006 AUX FH BRIDGE 3 CN 0.437 6.95 INSP AFH BRIDGE ELFC/P.C. POWER PROT BOOT 840130 008351 D22E006 AUX FH BRIDGE 3 CN 0,298 4.33 AFH BRIDGE E*ECTRICAL INSPECTION 840130 008353 D22E006 AUX FH BRIDGE 2 CN 0.260 3.22 AFH BRIDGE MECHANICAL INSPECTION 840302 008551 D22E006 AUX FH BRIDGE 3 CN 0.450 5.48 LUBE WHEELS-AFH BRIDGE 840316 008639 022E006 AUX FH BRIDGE 4 CN 0.318 5.13 REMOVE MAST AND TROLLEY FROM AFH BRIDGE 840402 008742 D22E006 AUX FH BRIDGE 4 CN 0.531 7.78 AFH BRIDGE INSPECTION 840402 008743 D22E006 AUX FH BRIDGE 2 CN 0.299 3.07 AFH BRIDGE FEEDER CABLE DRYOUT 840413 008817 D22E006 AUX FH BRIDGE 2 CN 0.300 4.57 P C. PENDANT BOX AND CABLE DRYOUT 840425 008889 D22E006 AUX FH BRIDGE 4 CN 0.706 11.52 STAGE CATWALK FOR HEAD & TROLLEY REMOVAL 840426 008900 D22E006 AUX FH BRIDGE 8 CN 1 767 26.33 DISMANTLE AFH BRIDGE AND STAGE 840430 008915 D22E006 AUX FH BRIDGE 3 CN 0.457 7 40 DISMANTLE AFH BRIDGE 840502 008932 D22E006 AUX FH QRIDGE 4 CN 0.535 9.87 CUT UP MISCELLANEOUS PARTS 840502 008934 D22E006 AUX FH BRIDGE 2 CN 0.400 4.63 LUBE AFH BRIDGE 840507 008949 D22E006 AUX FH BRIDGE 18 CN 2.779 39.68 CUT UP AFH BRIDGE MASTS SMD EQUIPMENT 840514 008998 D22E006 AUX FH BRIDGE 10 CN 1.319 21.02 LOWER AFH BRIDGE PARTS TO 347' LEVEL 840521 009036 D22E006 AUX FH BRIDGE 1 CM 0.050 0 77 TRASH INSPECTION-305' LEVEL TO 367' LEVEL

  • 840521 009036 D22E006 AUX FH BRIDGE 1 RP 0.150 1 40 TRASH INSPECTION-305' LEVEL TO 367' LEVEL
  • 840521 009036 022E006 AUX FH BRIDGE 1 IC 0.051 0.77 (RASH INSPECTION-305' LEVEL TO 367' LEVEL
  • 840521 009036 D22E006 AUX FH BRIDGE 1 CN 0.150 1.42 TRASH INSPECTION-305' LEVEL TO 367' LEVEL

DATE 022186 PAGE 10 PNO. 9 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. TA

  • .... E.. N UM8. E. R....................TIVIT.Y...............E.NTRG. C. ODE....RE.M.... O. U. R S.......................... S. K D. E. S.C R I P T. I. O N
  • DAT NUMBER.

AC H 840521 009037 D22E006 AUX FH BRIDGE .....,.... 3.361 48.87 DISASSEMBLE / CUT / REMOVE AFH TRCiLEY 25 CN 840525 009071 022E006 AUX FH BRIDGE 4 CN 0.597 9.68 CLEAN / PREP / INSPECT PARTS ON AFH BRIDGE

  • 840525 009071 D22E006 AUX FH BRIDGE 1 QA 0.109 1,68 CLEAN / PREP / INSPECT
  • ARTS ON AFH BRIDGE 840525 009072 D22E006 AUX FH BRIDGE 2 CN 0.178 2.03 DRAIN HYDRAULIC TANK-AFH BRIDGE 840608 009156 D22E006 AUX FH BRIDGE 7 CN 1.230 14.58 INSTALL PLATFORM-AFH BRIDGE 840611 009165 D22E006 AUX FH BRIDGE 29 CN 2.715 47,45 INSTALL PLATFORM-AFH BRIDGE
  • 840611 009165 D22E006 AUX FH BRIDGE 1 QA 0.072 1.48 INSTALL PLATFORM-AFH BRIDGE 840613 009196 022E006 AUX FH BRIDGE 4 CN 0.397 6.23 REMOVE CABLE & CONDUIT-AFH BRIDGE 840615 009209 D22E006 AUX FH BRIDGE 5 CN 0.650 10.92 MOVE AFH BRIDGE 840621 009258 D22E006 AUX FH BRIDGE 2 CN 0.260 2.70 INSTALL ANTI-0VERTURN DEVICES 840621 009268 D22E006 AUX FH BRIDGE 3 CN 0.191 3.27 RE-INSTALL 5 TON HOIST 840627 009320 D22E006 AUX FH CRIDGE 4 CN 0.284 7.28 RIG AND INSTALL PLATFORM PLATES 840803 009613 D22E006 AUX FH BRIDGE 4 CN 0.396 8.78 REMOVE COVER PLATE / DRILL HOLES 840913 009899 D22E006 AUX FH BRIDGE 4 CN 0.314 8.48 INSTALL BOLTS IN AFH BRIDGE PLATFORM 840914 009912 D22E006 AUX FH BRIDGE 4 CN 0.308 9.03 ERECT SCAFFOLD IN REFUELING CANAL 840917 009920 D22E006 AUX'FH BRIDGE 4 CN 0.203 5.97 AFH BRIDGE ELEC MODS / STAGE & INSTALL EQUIP 841002 010029 D22E006 AUX FH BRIDGE 3 CN 0.224 5.78 WALKDOWN/ INSPECT MAIN FH BRIDGE CIRCUITS 841004 010040 D22E006 AUX FH BRIDGE 9 CN 0.708 17.50 AFH BRIDGE ELECTRICAL MODIFICATIONS 841005 010046 D22E006 AUX FH BRIDGE 4 CN 0.272 8.83 REMOVE SCAFFOLD FROM REFUELING CANAL EX NUMBER. D22E006

. SUBTOTAL' ENTRG.P-TRCK PERS 195 EXPOS REM 23.726000 RWP HOURS. 385.68000 .840208 008419 D22E007 SERVICE STRUCT HOIST 7 CN 0.920 13.55 REMOVE MISSILE SHIELD HOIST A FRAME

  • 840208 008419 D22E007 SERVICE STRUCT HOIST 1 MM 0.116 1.98 REMOVE MISSILE SHIELD HOIST A FRAME jn. SUBTOTAL -

EXP-TRCK NUMBER. D22E007 PERS ENTRG. 8 n3 s EXPOS HOURS. 1.0360000 REM 15.530000 RWP .840305 008572 D22E008. MISSILE SHIELDS 4 CN 0.217 4.70 CUT HAND RAILS 840503 008938 022E008 MISSILE SHIELDS 3 CN 0.511 8.10 CUT UP MISSILE SHIELD PENDANT . SUBTOTAL - EXP-TRCK NUMBER = D22E008 PERS ENTRG. 7 EXPOS REM 0.7280000 RWP HOURS. 12.800000 .830301 005953 022E009 UNDERHEAD DATA ACQUI 2 RP 0.010 3.50 PREP ION CHAMBER FOR QUICK-SCAN RAD MEAS

  • 830301 005953 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.010 3.17 PREP ION CHAMBER FOR QUICK-SCAN RAD MEAS 830811 007181 D22E009 Uh0ERHEAD DATA ACQUI 1 CM 0.082 1.45 INSTALL MANIPULATOR SUPPORT TUBE-RVHSS
  • 830811 007181 D22E009 UNDERHEAD DATA ACQUI 1 OP 0.058 1.25 INSTALL MANIPULATOR SUPPORT TUBE-RVHSS
  • 830811 007181 D22E009 UNDERHEAD DATA ACQUI 2 MM 0.113 2.30 INSTALL MANIPULATOR SUPPORT TUBE-RVHSS 830812 007199 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.158 3.62 UNDERHEAD CHARACTERIZATION - VIDEO INSP
  • 830812 007199 022E009 UNDERHEAD DATA ACQUI 2 IC 0.102 2.40 UNDERHEAD CHARACTERIZATION - VIDED INSP
  • 830812 007199 D22E009 UNDERHEAD DATA ACQUI 1 RP 0.141 3.78 UNDERHEAD CHARACTERIZATION - VIDEO INSP 4830812 007199 D22E009 UNDERHEAD DATA ACQUI 2 CN 0.264 7.18 UNDERHEAD CHARACTERIZATION - VIDEO INSP 830815 007218 D22E009 UNDERHEAD DATA ACQUI 1 HP 0,130 3.48 UNDERHEAD CHARACTERIZATION
  • 830815 007218 D22E009 UNDERHEAD DATA ACQUI 1 RP O.171 3.63 UNDERHEAD CHARACTERIZATION
  • 830815 007218 D22E009 UNDERHEAD DATA ACQUI 2 CN 0.222 5.38 UNDERHEAD CHARACTERIZATION 830816 007241 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.159 3.92 UNDERHEAD CHARACTERIZATION /RV RAD MEAS
  • 830816 007241 022E009 UNDERHEAD DATA ACQUI 2 RP 0.258.

5.42 UNDERHEAD CHARACTERIZATION /RV RAD MEAS

  • 830816 007241 D22E009 UNDERHEAD DATA ACQUI 3 CN 0.357 9.30 UNDERHEAD CHARACTERIZATION /RV RAD MEAS

DATE 022186 PAGE 11 PNO 10 .TMI-2 UNC-DDS - ACTIVITY REPORT - RE ACTOR DEFUE L & OISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS RWP

  • D. ATE. NUMBE. R....UMBE.R

.........TIVIT.Y .. E. N T R G.,.C OD E.. .....EM...... HOURS. ...................DE.SCRIPTION N AC R TASK 830819 007266 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.200 1.50 PLACE SSTR NEUT DOSIM-HOT LEG PIPING

  • 830819 007266 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.455 2.73 PLACE SSTR NEUT DOSIM-HOT LEG PIPING
  • 830819 007266 D22E009 UNDERHEAD DATA ACQUI 1 MM 0.203 1.38 PLACE SSTR NEUT 00SIM-HOT LEG PIPING 830819 007272 D22E009 UNDERHEAD DATA ACQUI 2 IC 0 000 6.10 DATA ACQ SUPP/ INSTALL TV CAMERA & CHECK OP 830823 007306 022E009 UNDERHEt9 DATA ACQUI 2 IC 0.006 10.85 DECON TV CAMER A F OR RCDT 830823 007309 D22E009 UNDERHEn, DATA ACQUI 3 IC 0.001 7.68 REBAG DATA ACQUISITION TV CABLE 830824 007315 D22E009 UNDERHE AD DATA ACQUI 2 IC 0.000 0.88 DECON TV CAMERA 830829 007350 D22E009 UNDERHEAD DATA ACQUI 1 EL 0.082 1.77 CORE TOPOGRAPHY DATA ACQ TOOL STAGING
  • 830829 007350 D22E009 L'NDE RHE AD DATA ACQUI 4 IC 0.429 6.90 CORE TOPOGRAPHY DATA ACQ TOOL STAGING
  • 830829 007350 D22E009 UNDERHEAD DATA ACQUI 4 CN 0.359 7.27 CORE TOPOGRAPHY DATA ACO TOOL STAGING 830906 007392 D22E009 UNDERHEAD DATA ACQUI 1 EL 0.187 2.27 REMOVE TOPOG DATA ACQ TOOLS AND EQUIP.
  • 830906 007392 022E009 UNDERHEAD DATA ACQUI 2 IC 0.295 4.12 REMOVE TOPOG DATA ACO TOOLS AND EQUIP.
  • 830906 007392 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.108 2.65 REMOVE TOPOG DATA ACQ TOOLS AND EQUIP.
  • 830906 007392 D22E009 UNDERHEAD DATA ACQUI 2 CN 0.305 4.13 REMOVE TOPOG DATA ACQ TOOLS AND EQUIP.

830906 007393 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.068 1.48 UNDERHEAD RADIATION MEASUREM2NT

  • 830906 007393 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.047 1.47 UNDERHEAD RADIATION MEASUREMENT 830908 007425 D22E009 UNDERHEAD DATA ACQUI 4 HP 0.418 9.38 CORE DEBRIS GRAB SAMPLE EQUIP STAGING
  • 830908 007425 D22E009 UNDERHEAD DATA ACQUI 2 EL 0.213 3.45 CORE DEERIS GRAB SAMPLE EQUIP STAGING
  • 830908 007425 022E009 UNDERHEAD DATA ACQUI 4 IC 0.395 7.00 CORE DEBRIS GRAB SAMPLE EQUIP STAGING
  • 830908 007425 D22E009 UNDERHEAD DATA ACQUI 9 CN 0.885 19.70 CORE DEBRIS GRAB SAMPLE EQUIP STAGING 830909 007435 D22E009 UNDERHEAD DATA ACQUI 1 OP 0.075 0.92 SSTR DOSIM RETRIEVAL-SHALLOW END OF POOL
  • 830909 007e35 D22E009 UNDERHEAD DATA ACQUI 1 MM 0.184 0.73 SSTR DOSIM RETRIEVAL-SHAlt0W END OF POOL
  • 830909 007435 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.055 0.65 SSTR DOSIM RETRIEVAL-SHALLOW END OF POOL 830909 007443 D22E009 UNDERHEAD DATA ACQUI 1 ES 0.002 3.28 UNLOAD SSTR'S - HOT I&C SHOP I
  • 830909 007443 D22E009 UNDERHEAD DATA ACQUI 2 CN 0.004 6.47 UNLOAD SSTR'S - HOT I&C SHOP UN 830913 007475 022E009 UNDERHEAD DATA ACQUI 2 IC 0.344 3.25 INSTALL NUC INSTRUMENTATION COVER PLATES

'O

  • 830913 007475 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.151 2.35 INSTALL NUC INSTRUMENTATION COVER PLATES 830914 007482 D22E009 UNDERHEAD DATA ACQUI 1 EL 0.071 1.28 TRIAL FIT CANAL SEAL PLATE
  • 830914 007482 D22E009 UNDERHEAD DATA ACQUI 6 CN 0.565 9.99 TRIAL FIT CANAL SEAL PLATE 831003 007674 D22E009 UNDERHEAD DATA ACQUI 4 HP 0.459 10.72 CORE DEBRIS GRAB SAMPLE
  • 831003 007674 D22E009 UNDERHEAD DATA ACQUI 6 CN 0.627 16.40 CORE DEBRIS GRAB SAMPLE 831010 007728 D22E009 UNDERHEAD DATA ACQUI 2 OP 0.254 4.10 CORE DEBRIS SAMPLING EQUIPMENT DESTAGING
  • 831010 007728 D22E009 UNDERHEAD DATA ACQUI 1 MM 0.101 1.80 CORE DEBRIS SAMPLING EQUIPMENT DESTAGING
  • 831010 007728 D22E009 UNDERHEAD DATA ACQUI 1 CN 0.147 1.97 CORE DEBRIS SAMPLING EQUIPMENT DESTAGING 840119 008294 D22E009 UNDERHEAD DATA ACQUI 1 RP 0.000 0.47 MOVE PLENUM SAMPLE TO PNL TRAILER 840321 008675 D22E009 UNDERHEAD DATA ACQUI 12 CN 1.484 32 47 C "- DEBRIS GRAB SAMPLE - PHASE 2
  • 840321 008675 D22E009 UNDERHEAD DATA ACQUI 2 EL 0.173 3.05 Si DEBRIS GRAB SAMPLE - PHASE 2
  • 840321 008675 D22E009 UNDERHEAD DATA ACQUI 2 RP 0.407 8.33 "At DEBRIS GRAB SAMPLE - PHASE 2
  • 840321 008675 D22E009 UNDERHEAD DATA ACQUI 2.HP 0.351 8.23 aE DEBRIS GRAB SAMPLE - PHASE 2 840328 008723 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.130 3.25 JORE VIDEO MAPPING
  • 840328 008723 D22E009 UNDERHEAD DATA ACQUI 7 CN 1.064 26.57 CORE VIDEO MAPPING
  • 840328 008723 D22E009 UNDERHEAD DATA ACQUI 4 RP 0.597 15.87 CORE VIDEO MAPPING 840402 008745 D22E009 UNDERHEAD DATA ACQUI 1 HP 0.108 3.38 CORE VIDEO MAPPING
  • 840402 008745 D22E009 UNDERHEAD DATA ACQUI 6 CN 0.825 20.45 CORE VIDEO MAPPING
  • 840402 008745 D22E009 UNDERHEAD DATA ACQUI 4 RP 0.410 12 70 CORE VIDEO MAPPING 840425 008893 D22E009 UNDERHEAD DATA ACQUI 2 IC 0.223 4.87 RELOCATE CAMERA 7/ INSTALL NEW CAMERA

. SUBTOTAL - EXP-TRCK NUMBER. D22E009 PERS ENTRG. 146 EXPOS REM e 15.722000 RWP HOURS = 366.04000

DATE 022186 PAGE 12 PNO. 11 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D , RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP,

  • D. A T E... N UMB E. R.......

....B.E.R...,.........IVITY.......,........ E. N T R G. C. OD. E.......E.M.................................... K.D. E. S. C. R I P T I O N..........,. NUM ACT R HOURS TAS RCS WATER LEV. CNTRL 1 HP 0.444 1.47 'A' D-RING TUBING ON RC-V-110 & RC-V-111 830223 005899 022E010

  • 830223 005899 D22E010 RCS WATER LEV. CNTRL 4 CN 1.239 5.95

'A' D-RING TUBING ON RC-V-110 & RC-V-111 830302 005960 D22E010 RCS WATER LEV. CNTRL 1 OP 0.122 1.12 RCS DRAIN DOWN 830311 006025 D22E010 RCS WATER LEV. CNTRL 2 CN 0.340 1.65 MANOMETER INSTALLATION RV/ ADD SAMP LINE 830428 006363 D22E010 RCS WATER LEV. CNTRL 2 CN 0.288 3.13 MANOMETER INSTALLATION 'B' OTSG 830527 006609 D22E010 RCS WATER LEV. CNTRL 2 IC 0.002 2.85 CHECK CALIB ON RB SUMP LEVEL TRANSMITTER 830720 007001 D22E010 RCS WATER LEV. CNTRL 1 RP 0.088 1.12 INSP EQUIP 'D" RINGS / PREP FOR RCS DRAIN 830722 007025 022E010 RCS WATER LEV. CNTRL 1 HP 0.001 2.05 VERIFY DW-V-195 POSITION & BLANK FLANGE

  • 830722 007025 D22E010 RCS WATER LEV. CNTRL 1 OP 0.000 1.30 VERIFY DW-V-195 POSITION & BLANK FLANGE 830724 007037 D22E010 RCS WATER LEV. CNTRL 1 CN 0.050 1.62 CHECK VALVE POSITION /WDL-V-508 935, 509
  • 830724 007037 D22E010 RCS WATER LEV. CNTRL 1 OP 0.055 1.60 CHECK VALVE POSITION /WDL-V-SOS. 935, 509 830725 007032 D22E010 RCS WATER LEV. CNTRL 1 OP 0.179 2.22 RCS DRAINDOWN - TOP

^F CFT-A

  • 830725 007032 D22E010 RCS WATER LEV. CNTRL 1 RP 0.214 2.03 RCS DRAINDOWN - TO sF CFT-A
  • 830725 007032 D*2E010 RCS WATER LEV. CNTRL 1 HP 0.237 2.20 RCS DRAINDOWN - TO JF CFT-A 830726 007056 022E010 RCS WATER LEV. CNTRL 2 OP 0.151 2.22 RCS DRAINDOWN - 706 CF RVHSS
  • 830726 007056 022E010 RCS WATER LEV. CNTRL 1 HP 0.069 1.22 RCS DRAINDOWN - TOP OF RVHSS 830729 007078 022E010 RCS WATER LEV. CNTRL 2 OP 0.452 3.22 RCS DRAINDOWN - RVHSS &

'A' D-RING

  • 830729 007078 022E010 RCS WATER LEV. CNTRL 1 RP 0.091 2.03 RCS DRAINDOWN - RVHSS &

'A' D-RING

  • 830729 007078 D22E010 RCS WATER LEV. CNTRL 2 HP 0.535 3,15 RCS DRAINDOWN - RVHSS &

'A' D-RING 830729 007091 022E010 RCS WATER LEV. CNTRL 2 IC 0.026 6.45 SWITCH SENSING LINE/ CALIBRATE RC-LT-100 830801 007095 D22E010 RCS WATER LEV. CNTRL 1 OP 0.091 0.73 RCS DRAINDOWN - TOP OF CORE FLOOD TK 'A'

  • 830801 007095 D22E010 RCS WATER LEV. CNTRL 1 HP 0.138 0.75 RCS DRAINDOWN - TOP OF CORE FLOOD TK

'A' 830805 007131 D22E010 RCS WATER LEV CNTRL 2 UM 0.151 3.62 REMOVE TEMP CLOSURES FROM CRDM/INSTL CAP 840321 008673 022E010 RCS WATER LEV. CNTRL 1 CM 0 110 2.72 CRDM CLOSURE a *840321 008673 022E010 RCS WATER LEV, CNTRL 1 MM 0.109 2.75 CRDM CLOSURE on *840321 008673 D22E010 RCS WATER LEV. CNTRL 1 MD 0.090 2.72 CRDM CLOSURE Jh 840411 008804 D22E010 RCS WATER LEV. CNTRL 2 CM 0.147 2.75 CRDM CLOSURE I

  • 840411 008804 D22E010 RCS WATER LEV. CNTRL 1 MM 0.074 1.30 CRDM CLOSURE
  • 840411 008804 D22E010- RCS WATER LEV. CNTRL 1 MD 0.101 1.40 CRDM CLOSURE 840413 008816 D22E010 RCS WATER LEV. CNTRL 2 OP 0.425 3.27 RCS FILL & VENT /RCS LEAK INSPECTION
  • 840413 008816 D22E010 RCS WATER LEV. CNTRL 1 CN 0.170 2.33 RCS FILL & VENT /RCS LEAK INSPECTION 840615 009206 D22E010 RCS WATER LEV. CNTRL 2 OP 0.208 3.03 HOOK UP N-2 TO HOT LEGS AND PRESSURIZER
  • 840615 009206 022E010 RCS WATER LEV. CNTRL 1 HP 0.115 1.53 HOOK UP N-2 TO HOT LEGS AND PRESSURIZER 840618 009218 D22E010 RCS WATER LEV. CNTRL 7 OP 0.438 5.65 VENT CRD K-9/OPEN VLVS/ SECURE N-2 TO PZR
  • 840618 009218 D22E010 RCS WATER LEV. CNTRL 4 HP 0.324 3.13 VENT CRD K-9/0 PEN VLVS/ SECURE N-2 TO PZR
  • 840618 009218 D22E010 RCS WATER LEV. CNTRL 2 CN 0.098 1.98 VENT CRD K-9/0 PEN VLVS/ SECURE N-2 TO PZR 840627 009325 022E010 RCS WATER LEV. CNTRL 2 CN 0.227 4.60 REMOTE INDICATION FOR PRIMARY WATER 840628 009337 D22E010 RCS WATER LEV. CNTRL 2 OP 0.026 0.82 INITIATE AND SECURE RCS DRAINDOWN 840714 009477 D22E010 RCS WATER LEV. CNTRL 2 IC 0.205 5.85 IIF PRE-OP TEST

$840714 009477 D22E010 RCS WATER LEV. CNTRL 1 CN 0.130 2.07 IIF PRE-OP TEST . SUBTOTAL - EXP-TRCK NUMBER. D22E010 PERS ENTRG. 67 EXPOS REM 7.9600000 RWP HOURS. 101.60000 .830124 005636 D22E012 CANAL ACCESS 4 CN 0.114 11.30 ASSEMBLE SCAFFOLDING IN REFUEL CANAL 830127 005670 D22E012 CANAL ACCESS 3 CN 0.476 7.82 INSTALL SCAFFOLD-STRWELL TO REFUEL CANAL 830209 005781 D22E012 CANAL ACCESS 1 OP 0.078 1.12 MOVE AUX FUEL HANDLING BRIDGE TROLLEY 840330 008735 D22E012 CANAL ACCESS 2 CN 0.174 3.32 INSPECT SCAFFOLD TO REFUELING CANAL 840425 008894 D22E012 CANAL ACCESS 1 OA 0.034 1.35 WELD INSPECTION-REFUEL CANAL L*NER PLATE

  • 840425 008894 D22E012 CANAL ACCESS 1 CN 0.040 1.37 WELD INSPECTION REFUEL CANAL LINER PLATE

DATE 022186 PAGE 13

PNO, 12

.TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP, .............. T A S. K..D E. S.C. R I P T.I O. N

  • DATE... NU.MB. E.R..... U.MB. E. R..........=.TIVIT.Y......_.......,..................E.M....... U. R S...........

N AC ENTRG. CODE R HO 4 CN 0.123 5.49 INSPECT LINER PLATE WELDS 840523 009065 D22E012 CANAL ACCESS 840612 009183 D22E012 CANAL ACCESS 8 CN 0.559 10.15 REMOVE REFUEL CANAL SCAFFOLD 840622 009273 D22E012 CANAL ACCESS 4 CN 0.382 8.49 RE-INSTALL STAIR SCAFFOLD 840626 009311 D22E012 CANAL ACCESS 14 CN 1.539 21.85 CUT CABLE BRIDGES 840630 009344 D22E012 CANAL ACCESS 2 CN 0.130 2.52 CUT UP MISCELLANEOUS STEEL 840719 009494 D22E012 CANAL ACCESS 4 CN 0.349 8.75 REMOVE SCAFFOLD FROM REFUEL CANAL 840731 009591 D22E012 CANAL ACCE.SS 3 CN 0.316 6.20 REPLACE SCAFFOLD . SUBTOTAL - EXP-TRCK NUMBER 022E012 PERS ENTRG. 51 EXPOS REM 4.3140000- = RWP HOURS = 89.730000 .830715 006963 022E013 SERVICE AIR 4 CN 0.127 2.82 INSTALL SERVICE AIR & SUMP ISOLATION 830809 007168 022E013 SERVICE AIR 1 OP 0.068 1.20 FAB MANIFOLD / INSTALL BULLARD FILTER

  • 830809 007168 D22E013 SERVICE AIR 2 IC 0.131 2.60 FAB MANIFOLD / INSTALL BULLARD FILTER
  • 830809 007168 022E013 SERVICE AIR 1 UM 0.048 1.30 FAB MANIFOLD / INSTALL BULLARD FILTER 830811 007182 D22E013 SERVICE AIR 2 CN 0.448 4.10 CONTAINMENT SERVICE AIR TEST
  • 830811 007182 D22E013 SERVICE AIR 1 OP 0.226 2.03 CONTAINMENT SERVICE AIR TEST 830812 007200 D22E013 SERVICE AIR 2 CN 0.192 2.53 REPLACE SERVICE AIR QUICK DISCONNECT 830816 007243 D22E013 SERVICE AIR 2 CN 0.460 3.70 CONTAINMENT SERVICC AIR TEST
  • t40816 007243 D22E013 SERVICE AIR 1 OP 0.248 1.77 CONTAINMENT SERVICE AIR TEST 831212 008074 D22E013 SERVICE AIR 2 CN 0.286 3.62 STANDARDIZE SERVICE AIR CONNECTIONS 840621 009260 D22E013 SERVICE AIR 6 CN 0.742 8.80 CHANGE OUR AIR CONNECTOR AND TEMPERATURE

. SUBTOTAL - EXP-TRCK NUMBER = D22E013 PERS ENTRG. 24 EXPOS REM HOURS. 2. 9760000 = e, RWP 34.470000 en 830214 005827 D22E014 TEMPORARY POWER-4 CN 0.010 5.30 RUN CONDUIT / PULL WIRE IN OVERHEADS un *830214 005827 D22E014 TEMPORARY POWER 2 L.~ 0.005 2.88 RUN CONDUIT / PULL WIRE IN OVERHEADE s 830218 005867 D22E014 TEMPORARY POWER 11 CN 0.004 16.40 PULL CABLE THROUGH TRAYS & CONDUIT 830907 007417 D22E014 TEMPORARY. POWER 2 CN 0.185 2.70 CLEAN CABLES AT POWER BUGGY . SUBTOTAL - EXP-TRCK NUMBER D22E014 PERS ENTRG. 19 EXPOS REM 0.2040000' RWP HOURS. 27.280000 .830512 006481 022E016 CABLE DISC.ONNECT 3 EL 0.363 6.78 HEAD SERVICE STRUCTURE POWER DISCONNECT . SUBTOTAL - EXP-TRCK NUMBER 022E016 PERS -ENTRG = 3 ' EXPOS REM 0.3630000 RWP HOURS. 6.7800000 .830325 006133 022E018 HEAD STORAGE STAND 1 QA 0.159 1.97 HEAD STORAGE STAND INSPECTION 830711 006910 D22E018 HEAD STORAGE STAND 2 CN 0.082 1.60 REMOVE NUTS FROM ANCHOR BOLTS-HEAD STAND 830714 006949 D22E018 HEAD STORAGE STAND 2 CN 0.203 2.12 REMOVE NUTS FROM ANCHOR BOLTS-HEAD STAND 840625 009290 D22E018 HEAD STORAGE STAND 8 UM 1.174 16.15 WORK ON HEAD STORAGE STAND . SUBTOTAL' - EXP-TRCK NUMBER = D22E018 PERS ENTRG. 13 ' EXPOS REM. 1.6180000 RWP HOURS. 21.840000 .830803 007121 D22E019 INTERNALS INDEX FIXT 1 HP 0.000 1.25 INSPECT 3 LIFTING PENDANTS FOR IIF

  • 830803 007121 D22E019 INTERNALS INDEX FIXT 1 OA 0.000 0.73 INSPECT 3 LIFTING PENDANTS FCR IIF
  • 830803 007121 D22E019 INTERNALS INDEX FIXT 1 MD 0.000 1.05 INSPECT 3 LIFTING PENDANTS FOR IIF

DATE 022186 PAGE 14 PNO 13 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D RWP .EXP-TRCK. PERS. DEPT

EXPOS, RWP.

.. NUMBER. NUMBER ACTIVITY ENTRG. ............,.....................I.ON TASK DESCRIFF .......,...E.M CODE R HOURS.

  • DATE 830810 007179 D22E019 INTERNALS INDEX FIXT 1 RW 0.002 0.53 INSPECT IIF PENDANT ASSEMBLY
  • 830810 007179 D22E019 INTERNALS INDEX FIXT 1 CN 0.005 0.52 INSPECT IIF PENDANT ASSEMBLY 840109 008220 D22E019 INTERNALS INDEX FIXT 2 QA 0.316 5.15 NDE TRIPOD WELDS / INSPECT TURNBUCKLES
  • 840109 008220 D22E019 INTERNALS INDEX FIXT 2 CN 0.236 3.78 NDE TRIPOD WELDS / INSPECT TURNCUCKLES 840307 008581 D22E019 INTERNALS INDEX FIXT 5 CN 0.600 8.52 STAGE VACUUMS / MEASURE IIF 840323 008689 D22E019 INTERNALS INDEX FIXT 2 QA 0.125 2.20 NDE TRIPOD WELDS 840612 009185 D22E019 INT *RNALS INDEX FIXT 4 CN 0.354 5.80 PRE P ARE A FOR IIF 840627 009323 D22E019 INTERNALS INDEX FIXT 40 CN 6.159 83.63 STAGE AND ASSEMBLE IIF PLATFORM 840703 009371 D22E019 INTERNALS INDEX FIXT 20 CN 1.447 36.20 ASSEMBLE IIF PLATFORM / INSTALL ENV SKIRT
    • 840703 009371 D22E019 INTERNALS INDEX FIXT 1 QA 0.075 1.17 ASSEMBLE IIF PLATFORM / INSTALL ENV SKIRT 840703 009381 D22E019 INTERNALS INDEX FIXT 4 CN 0.449 9.05 INSTALL RCS SAMPLE PUMP 840705 009382 D22E019 INTERMALS INDEX FIXT 5 CN 0.335 6.17 UNDER WATER LIGHTING FOR IIF 840706 009387 D22E019 INTERNALS INDEX FIXT 3 CN 0.329 4.45 INSTALL RCS SAMPLE PUMP 840707 009393 D22E019 INTERNALS INDEX F IXT 8 CN 0.745 18.25 ASSEMSLE AND ATTACH LIFT RIG TO IIF 840711 009426 D22E019 INTERNALS INDEX FIXT 2 CN 0.113 1 92 IIF UNDER WATER LIGHTING 840711 009430 D22E019 INTERNALS INDEX FIXT 2 CN 0.203 3.95 POWER FOR IIF & RCS SAMPLE PUMP 840717 009478 D22E019 INTERNALS INDEX FIXT 3 CN 0.164 3.67 STAGE IJ F PLATFORM ACCESS LADDER 840718 009479 D22E019 INTERNALS INDEX FIXT 4 CN O 774 11.08 INSTALL 3V PLENUM MISTING SYSTEM UNIT 840721 009512 022E019 INTERNALS INDE X FIXT 11 CN 0.685 15.76 INSTALL GASKETS & SPACERS ON IIF
  • 840721 009512 D22E019 INTERNALS INDEX FIXT 1 QA 0 020 0.58 INSTALL GASKETS & SPACERS ON IIF 840723 009522 D22E019 INTERNALS INDEX FIXT 6 CN 0.502 10.75 LEVEL IIF PLATFORM
  • 840723 009522 D22E019 INTERNALS INDEX FIXT 4 UM 0.395 8.93 LEVEL IIF PLATFORM
  • 840723 009522 D22E019 INTERNALS INDEX FIXT 2 IC 0.052 1.45 LEVEL IIF PLATFORM
  • 840723 009522 D22E019 INTERNALS INDEX FIXT 3 OP 0.279 6.97 LEVEL IIF PLATFORM I *840723 009522 D22E019 INTERNALS INDEX FIXT 6 MM 0.563 14.03 LEVEL IIF PLATFORM LM 840723'009541 D22E019 INTERNALS INDEX FIXT 2 MM 0.072 1.73 IIF BUSHING - CAMERA STAND Ch *840723 009541 D22E019 INTERNALS INDEX FIXT 1 RP 0.037 0 85 IIF BUSHING - CAMERA STAND 8 *840723 009541 022E019 INTERNALS INOEX FIXT 1 CM 0.036 0.82 IIF BUSHING - CAMERA STAND 840726 009558 D22E019 INTERNALS INDEX FIXT 9 CN 0.934 17.65 INSTALL IIF PLATFORM
  • 840726 0095S3 D22E019 INTERNALS INDEX FIXT 1 MM 0.080 2.65 INSTALL IIF PLATFORM 840726 009559 D22E019 INTERNALS INDEX FIXT 2 CN 0.158 3.47 POWER FOR IIf SAMPLE PUMP / LIGHTING 840726 009560 D22E019 INTERNALS INDEX FIXT 3 CN 0.302 6.53 RCS SAMPLE PUMP INSTALLATION 840727 009562 D22E019 INTERNALS INDEX FIXT 1 OP 0.011 0.47 INSTALL IIF TIEDCWN
  • 840727 009562 D22E019 INTERNALS INDEX FIXT 5 UM 0.193 4.77 INSTALL IIF TIEDOWN
  • 840727 009562 D22E019 INTERNALS INDEX FIXT 5 MM 0.161 4.42 INSTALL IIF TIEDOWN
  • 840727 009562 D22E019 INTERNALS INDEX FIXT 1 CM 0.010 0.42 INSTALL IIF TIEDOWN
  • 840727 009562 D22E019 INTERNALS INDEX FIXT 1 RP 0.010 0.45 INSTALL IIF TIEDOWN 840730 009572 D22E019 INTERNALS INDEX FIXT 1 QA 0.126 1.93 RCS SAMPLE DUMP INSTALLATION
  • 840730 009572 D22E019 INTERNALS INDEX FIXT 3 CN 0.288 5.59 RCS SAMPLE DUMP INSTALLATION 640731 009593 D22E019 INTERNALS INDEX FIXT 4 CN 0.238 6.55 REMOVE / DISMANTLE IIF 840817 009712 D22E019 INTERNALS INDEX FIXT 1 QA 0.075 1.45 IIF PROCESSING HOSE LEAK TEST
  • 840817 009718 D22E019 INTERNALS INDEX FIXT 1 CN 0.094 2.63 IIF PROCESSING HOSE LEAK TEST 840913 009902 D22E019 INT INDEXING FIXT.

4 CN 0.462 11.00 REMOVE PLENUM MISTING SYSTEM . SUBTOTAL - EXP-TRCK NUMBER = D22F019 PERS ENTRG. 191 18.214000 EXPOS REM = RWP HOURS. 340.92000 .830729 007089 D22E021 SDS MODIFICATIONS 1 ES 0.008 4.62 LEAKRATE & HYDRO TEST SUMP SUCKER LINE

  • 830729 007089 D22E021 SDS MODIFICATIONS 8 CN 0.019 15.65 LEAKRATE & HYDRO TEST SUMP SUCKER LINE
  • 830729 007089 D22E021 SDS MODIFICATIONS 1 QA 0.005 3.15 LEAKRATE & HYDRO TEST SUMP SUCKER LINE

EATE 022186 PAGE 15 PNO 14 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP,

  • D. A TE... NUMBE.R....... E. R........ AC. T IV. I T Y NUMB

................E.NTRG CO.D.E....E.M......S..............................E.SC.RIPTION , R HOUR TASK D EX NUMBER. D22E021 . SUBTOTAL ENTRG.P-TRCK PERS 10 EXPOS, REM 0.0320000 RWP HOURS =~23.420000 .840523 009063 D22E02? GUIDE STUDS 1 UM 0.099 2.33 TORQUE STUD RACK /RMVE 2 STUDS / FILL HOLES

  • 840523 009063 D22E022 GUIDE STUDS I MM 0.095 2.77 TORQUE STUD RACK /RMVE 2 STUDS / FILL HOLES

. SUBTOTAL - EXP-TRCK NUMBER = D22E022 PERS ENTRG. 2 EXPCS REM. 0.1940000 RWP HOURS. 5.1000000 .830826 007318 D22E023

    • D

RING CATWALK 2 CN 0.030 0.77 INSTALL HANDRAIL - TOP OF 'B' D-RING 840630 009345 D22E023 D RING CATWALK 3 CN 0.173 3.20 STAGE SCAFFOLD - 367* LEVEL TO RVHSS 840724 009543 D22E023 D RING CATWALK 4 CN 0.356 5.50 INSTALL CATWALK - RVHSS TO D RING . SUBTOTAL - EXP-TRCK NUMBER = D22E023 PERS ENTRG = 9 EXPOS REM 0.5590000 RWP HOURS. 9.4100000 .831219 008121 022E024 SPOOL PIECE REMOVAL 2 CN 0.308 5.67 STATOR COOLING WATER PIPING REMOVAL 840314 008630 D22E024 SPOOL PIECE REMOVAL 5 CN 1.020 13.39 REMOVE STATOR COOLING WATER PIPING 840314 008630 D22E024 SPOOL PIECE REMOVAL 1 MM 0.080 1.22 REMOVE STATOR COOLING WATER PIPING 840314 008630 D22E024 SPOOL PIECE REMOVAL 1 QA 0.150 2.22 REMOVE STATOR COOLING WATER PIPING . SUBTOTAL - EXP-TRCK NUMBER. D22E024 PERS ENTRG. 9 EXPOS REM 1.5580000 = dn. RWP HOURS. 22.500000 %a 840724 009546 D22E026 FLOOD LINE 6 CN 0.004 8,23 INSTALL TAG LINES ON MISTING SYSTEM e 840928 010003 022E026 FLOOD LINE 2 CN 0.092 1.95 TEST CABLES FOR OWCS USE . SUBTOTAL - EXP-TRCK NUMBER = D22E026 PERS ENTRG. 8 EXPOS REM HOURS. 0.0960000 = RWP 10.180000 .840215 008463 D22E028 FILL PROVISION 14 CN 0.032 29.58 INSTALL HANGERS 840221 008506 D22E028 FILL PROVISION 6 CN 0.004 15.17 INSTALL PIPE HANGERS 840404 008764 D22E028 FILL PROVISION 2 HP 1.081 3.43 REMOVE RTD'S 840404 008764 D22E028 FILL PROVISION 2 OP 0.310 2.32 REMOVE RTD'S 840404 008764 D22E028 FILL PROVISION 1 CN 0.240 1.25 REMOVE RTD'S 840406 008769 D22E028 FILL PROVISION 1 HP O.540 1.72 REMOVE RTD'S 840406 008769 D22E028 FILL PROVISION 2 CN 0.566 2.97 REMOVE RTD'S 840406 008769 D22E028 FILL PROVISION 1 QA 0.159 1.20 REMOVE RTD'S 840723 009538 D22E028 FILL PROVISION 3 CN 0.350 7.05 TEST FUEL TRANSFER CANAL FILL SYSTEM 840928 010006 D22E028 FILL PROVISION 6 CN 0.071 6.37 FPB WEST HOUSE-CONNECT TEST EQUIP & TEST 841019 010133 D22E028 FILL PROVISION 2 HP 0.032 4.63 FHB WEST HOUSE-CONNECT TEST EQUIP & TEST

  • 841019 010133 D22E028 FILL PROVISION 6 CN 0.160 14.43 FHB WEST HOUSE-CONNECT TEST EQUIP & TEST

. SUBTOTAL - EXP-TRCK NUMBER = D22E028 PERS ENTRG. 46 EXPOS REM 3.5450000-RWP HOURS. 90.120000 .840712 009438 022E029 LIFT MONITRG EQUIP 5 CN 0.449 7.74 INSTALL HEADLIFT MONITORING SYSTEM $840712 009438 D22E029 LIFT MONITRG EQUIP 2 IC 0.136 2.13 INSTALL HEADLIFT MONITORING SYSTEM 840716 009460 D22E029 LIFT MONITRG EQUIP 8 HP 1.059 19.08 INSTALL AREA RADIATION MONITORING SYSTEM

DATE 022186 PAGE 16 PNO 15 TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. TASK DESCRIPTION N ACTIVITY ENTRC CODE REM HOURS.

  • .D. AT E.. NUMBE R........,.. UMBER 840731 009592 022E029 LIFT MONITRG EQUIP 10 CN 1.249. 20.45.

. INSTALL ARE A R ADI ATION MONITORING SYSTEM 841116 010305 D22E029 LIFT MONIT. EQUIP 1 RC 0.069 2.18 REMOVE HEADLIFT P.*D MONITORS /INSTL R0074

  • 841116 010305 D22E029 LIFT MONIT. EQUIP 3 HP 0.234 6.34 REMOVE HEADLIFT RAD MONITORS /INSTL R0074

. SUBTOTAL - EXP-TRCK NUMBER = D22E029 PERS ENTRG = 29 3.1960000 EXPOS REM. NWP HOURS. 57.920000 l . 83f513 006197 D22E030 REMOVE HEAD 1 RP 0.157 2.38 SOURCE CHECK NUC INSTRUMENTATION J0004

  • 83i513 006497 D22E030 REMOVE HEAD 1 CN 0.155 2.33 SOURCE CHECK NUC INSTRUMENTATION J0004
  • 810313 006497 D22E030 REMOVE HEAD 1 HP 0.173 2.48 SOURCE CHECK NUC INSTRUMENTATION J0004 830520 006542 D22E030 REMOVE HEAD 1 HP 0.108 2.F0 SOURCE CHECK NUC INSTRUMENTATION J0004
  • 830520 006549 D22E030 REMOVE HEAD 2 IC 0.284 5.37 SOURCE CHECK NUC INSTRUMENTATION J0004 830603 006641 D22E030 ' REMOVE HEAD 1 CN 0.099 1.23 IN CONTAINk:NT INSPECTION 840201 008377 D22E030 REMOVE HEAD 5 CN 1 373 17.33 INSTALL EQUALIZER BRACKETS ON LOAD FPAME
  • 840201 008377 D22E030 REMOVE HEAD 1 EL 0 225 3.45 INSTALL EQUALIZER BRACKETS ON LOAD FRAME 840206 008401 D22E030 REMOVE HEAD 5 CN 0.420 7.78 INSTALL EQUALIZER 89ACKETS
  • 840206 008401 D22E030 REMOVE HEAD 1 EL 0 089 1.52 INSTALL EQUALIZER ERACKETS 840312 008605 D22E030 REMOVE HEAD 4 CN 0.445 8.40 CUT UP'HEADLIFT CLINGS
  • 840312 008605 D22E030 REMOVE HEAD 1 MM 0.111 1 77 CUT UP HEADLIFT SLINGS 840507 008947 D22E030 REMOVE HEAD 2 CN 0.617 4.43 HOIST POWER TO WALL MOUNTED JIB CRANE 840511 008986 D22E030 REMOVE HEAD 2 CN 0.148 3 37 HOIST POWER TO WALL MOUNTED JIB CRANE 840514 009011 D22E030 REMOVE HEAD 2 CN 0.311 4 22 CUT HEADLIFT SLINGS 840710 009424 D22E030 REMOVE HEAD 2 CN 0.160 2.28 INSPECT HEADLIFT PENDANTS 840711 009425 D22E030 REMOVE HEAD 2 CN O 292 4.82 MODIF Y SERVICE STRUCTURE SUPPORTS 840718 009484 D22E030 REMOVE HEAD 3 CN 0.175 4.32 INSTALL CHANNELS UNDER HEAD PENDT STAND jn 840718 009488 022E030 RfMOVE HEAD 1 CM 0.131 2.30 STAGE HEAD BOOT /INSTL ":ADLIFT INDICATOR
  • 840718 009488 D22E030 REMOVE HEAD 1 OP 0.090 2.10 ST AGE HE AD BOOT /INSTL HE ADLIF T INDICATOR 00
  • 840718 009488 022E030 REMOVE HEAD 1 UM 0.072 2.17 STAGE HEAD BOOT /INSTL HEADLIFT INDICATOR
  • 840718 009488 D22E030 REMUVE HEAD 1 CN 0.105 2.53 STAGE HEAD BOOT /INSTL HEADLIFT INDICATOR
  • 840718 509488 D22E030 REMOVE HEAD 1 RP 0.110 2.50 STAGE HEAD BOOT /INSTL HEADLIFT INDICATOR 840722 009517 D22E030 REMOVE HEAD 7 MM 0.435 8.75 INSPECT LEVELS 347' AND 367'
  • 840722 009517 D22E030 REMOVE HEAD 1 MD 0.076 1.38 INSPECT LEVELS 347 ' AND 367'
  • 840722 009517 D22E030 REMOVE HEAD 1 CN 0.105 2.07 INSPECT LEVELS 347' AND 367*

840723 009539 D22E030 REMOVE HEAD 1 EL 0.099 2.27 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 7 OP 0.620 12.18 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 46 MM 5.694 113.36 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 8 HP 1 295 26.25 HEAD REMOVAL /IIF INS'6LLATION 840723 009539 D22E030 REMOVE HEAD 13 UM 1.513 22.03 HEAD REMOVAL /IIF INS.ALLATION 840723 009539 D22E030 REMOVE HEAD' 8 IC 0.835 19.13 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD. 2 CM 0.093 2.05 HEAD REMOVAL /IIF I N S T A '. L A T I ON 840723 009539 D22E030 REMOVE HEAD 2 RP 0.180 2.90 HEAD REMOVAL /IIF INSTALLATION 840723 009539 D22E030 REMOVE HEAD 4 CN 0.491 7.65 HEAD REMOVAL /IIF INSTALLATION 840724 009547 D22E030 REMOVE HEAD 1 EL 0.098 2.38 RLPAIR CAMERA

  • 840724 009547 022E030 REMOVE HEAD 2 IC 0.341 5.12 REPAIR CAMERA 840725 009548 D22E030 REMOVE HEAD 1 IC 0.137 2 15 REFAIR STUD HDLE CAMERA 840725 009550 D22E030 REMOVE HEAD ^

4 CN 0.442 6.85 ERECT SCAFFOLD AT HEAD STORAGE STAND 840727 009565 D22E030 REMOVE HEAD 3.CN 0.293 4.62 REMOVE SCAFFOLD AT HEAD STORAGE STAND . SUBTOTAL - EXP-TRCK NUMBER = D22E030 PERS ENTRG = 153 18.597000 EXPOS REM.

DATE 022186 PAGE 17 PNO 16 .TMI-2 UNC. DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D RWP EXP-TRCK. PERS DEPT EXPOS. RWP

  • ... E... h UM B. E R.

........CTIVITY ..C OD E.....E M ...OURS..

  • DAT NUMCER A

ENTRG R H .................... TASK DESCRI.PTION RWP HOURS. 332.82000 840312 008602 D22E031 IST PASS-STUD DETENS 1 EL 0.177 3.08 RIG STUD TENSIPNERS & NUT RUNNERS

  • 840312 008602 D22E031 IST PASS-STUD DETENS 6 CN 1.492 16 02 RIG STUD TENSI,dE RS & NUT RUNNERS 840312 008603 D22E031 IST PASS-STUD DETENS 12 UM 2 988 27.57 DE TENSIONING F IRST PASS-RV STUDS 840312 008603 D22E031 IST PASS-STUD DETENS 22 MM 6.026 56.90 DETENSIONING FIRST PASS-RV STUDS 840312 008603 022E031 IST PASS-STUD DETENS 4 OP 1.547 13 15 DETENSIONING FIRST PASS-RV STUDS 840312 008603 022E031 IST PASS-STUD DETENS 2 MD 0.505 4.58 DETENSIONING F IRST PASS-RV STUDS 840312 008603 D22E031 IST PASS-STUD DETENS 4 RP 1 058 10 90 DETENSIONING FIRST PASS-RV STUDS 840312 008603 D22E031 IST PASS-STUD DETENS 2 CN 0.560 6 77 DETENSIONING FIRST PASS-RV STUDS 840321 008676 D22E031 IST PASS-STUD DETENS 1 MM 0.078 1.42 REMOVE STUD TENSIONERS FROM HOIST
  • 840321 008676 D22E031 IST PASS-S.TUD DETENS 3 CN 0.258 3.98 REMOVL STUD TENSIONERS FROM HOIST

. SUBTOTAL - EXP-TRCK NUMBER D22E031 PERS ENTRG = 57 EXPOS REM. 14.689000 RWP MOURS = 144.37000 841005 010049 D22G001 PLENUM REMOVAL 1 MM 0.055 0 70 CHANGE DESSICANT & AIR FILTER-IIF 850123 010736 D22G001 PLENUM REMOVAL 3 CN 0.258 5 13 WALKDOWN ELECTRICAL FOR CATWALK REMOVAL 850201 010791 D22G001 PLE NUM REMOVAL 1 MM 0 047 1.08 CHANGE DESSICANT-IIF AIR COMPRESSOR 850208 010845 022G001 PLEN'JM REMOVAL 2 CN 0.073 1 73 REROUTE SERVICE AIR HOSES-D RING CATWALK

  • 850208 010845 D22G001 PLENUM REMOVAL 3 IC 0.452 7.94 REROUTE SERVICE AIR HOSES-D RING CATWALK 850222 010952 D22G001 PLENUM REMOVAL 4 CN 3.292 5.85 REMOVE NORTH D RING CATWALK 850314 011127 D22G001 PLENUM REMOVAL 4 CN 0.271 5.12 REINSTALL NORTH D RING CATWALK

. SUBTOTAL - EXP-TRCK NUMBER 022G001 PERS ENTRG. 18 tn EXPOS REM = 1.4480000 us. RWP HOURS 27.550000 e 840324 003696 D22H001 FUEL REMOVAL 2 CN 0.243 4.8! PENETRATION INSPECTION-CORE FLOOU TANK A 840919 009943 D22H001 FUEL REMOVAL 3 CN 0.466 6.47 FH BRIDGE WALKDOWN/ CIRCUIT INSPECTION 840925 009980 022H001 FUEL REMOVAL 3 CN 0 35!. 9.18 AS-BUILT MEAS OF DAM KEY-REFUEL CANAL 841106 101240 D22H001 FUEL REMOVAL 8 CN 0.886 18 73 REMOVE ELECTRICAL EQUIPMENMT FOR FTS . SUBTOTAL - EXP-TRCK NUMBER = D22H001 PERS ENTRG. 16 EXPOS REM 1.9460000 = RWP HOURS. 39.230000 . 830429 006381 D35E001 SHIELD RVHSS 2 CN 0.257 3.53 REMOVE RVHSS SHLDING FRAME INTERFERENCE

  • 830429 006381 D35E001 SHIELD RVHSS 1 HP 0.150 1.85 REMOVE RVHSS SHLDING FRAME INTERFERENCE 830502 006397 D35E001 SHIELD RVHSS 4 CN 0.522 7.05 REMOVE RVHSS SHLDING FRAME INTERFERENCE 830502 0C0338 D35E001 SHIELD RVHSS 1 MM 0.080 2.10 INSTALL UPPER SHIELD SUPPORT ON RV HEAD
  • 830502 006398 D35E001 SHIELD RVHSS 10 CN 1.519 22.82 INSTALL UPPER SHIELD SUPPORT ON RV HEAD 830502 006409 D35E001 SHIELD RVHSS 5 CN 0.262 4.28 INSTALL LOWER SHIELD SUPPORT ON RV HEAD 840227 008528 D35E001 SHIELD RVHSS 3 CN 0.408 5.12 REMOVE RVHSS SHIELDING SUPPORT

. SUBTOTAL - EXP-TRCK NUMBER. = D35E001 PERS ENTRG. 26 EXPOS REM 3.1980000 = RWP HOURS. 46.750000 .840621 009257 D35E002 SHLD HEAD STOR STAND 19 CN 2.762 34.15 STAGE SHIELDING EQUIPMENT 840625 009295 D35E002 SHLD HEAD STOR STAND 15 CN !.715 27 85 STAGE EQUIPMENT FOR VIDEO CONSOLE AREA 840626 009308 D35E002 SHLD HEAD STOR STAND 5 UM. 0,799 10.62 INSTALL HEAD STORAGE STAND SHIELDING 840626 009309 035E002 SHLD HEAD STOR STAND 1 IC 0.100 2.05 FILL WATER COLUMNS FOR TEMP. SHIELDING l 1

  • 840626 009309 D35E002 SHLD HEAD STOR STAND 1 EL 0.103 2.05 FILL WATER COLUMNS FOR TEMP. SHIELDING I

1 l s o

DATE 022186 PAGE 18 PNO 17 .THI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY H 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. TASK DE ......E.RNUMB........... C..T I V I T Y....... ..ENTRG. .... E. M ...........................S.C.RIPTION A CODF R HOURS.

  • DATE.. UMB E. R.

.N . FILL WATER COLUMNS FOR TEMP. SHIELDING.

  • 840626 009309 D35E002 SHLD HEAD STOR STAND 1 CM 0.095 1.95
  • 840626 009309 D35E002 SHLD HEAD STOR STAND 1 OP 0.100 1 43 FILL WATER COLUMNS FOR TEMP. SHIELDING
  • 840626 009309 035E002 SHLD HEAD STOR STAND 1 UM 0.156 2.12 FILL WATER COLUMNS FOR TEMP SHIELDING 840628 009336 D35E002 SHLD HEAD STOR STAND 1 OP 0.090 1.37 WET VAC RESIDUAL WATER - 347' LEVEL
  • 840628 009336 D35E002 SHLD HEAD STOR STAND 2 CM 0.335 3.15 WET VAC RESIDUAL WATER - 347' LEVEL
  • 840628 009336 D35E002 SHLD HEAD STOR STAND 2 UM 0.181 3.20 WET VAC RESIDUAL WATER - 347' LEVEL

'840629 009338 D35E002 SHLD HEAD STOR STAND 7 CN 0.844 12.43 STAGE AND RIG 8' WATER COLUMNS 840629 009339 D35E002 SHLD HEAD STOR STAND 11 UM 1.358 23.67 INSTALL HEAD STORAGE STAND SHIELDING 840702 009357 D35E002 SHLD HEAD STOR STAND 8 CN 1.093 20.04 FILL WATER COLUMNS AROUND HEAD STOR STND l

  • 840702 009357 D35E002 SHLD HEAS STOR STAND 1 RP 0.081 0.93 FILL WATER COLUMNS AROUND HEAD STOR STND i
  • 840702 009357 D3tE002 SHLD HEAD STOR STAND 3 OP 0.333 5.32 FILL WATER COLUMNS AROUND HEAD STOR STND
  • 840702 009357 D35E002 SHLD HEAD STOR STAND 1 CM 0.140 2.03 FILL WATER COLUMNS AROUND HEAD STOR STND 840702 009358 D35E002 SHLD HEAD STOR STAND 21 UM 2.672 54.13 INSTALL HEAD STORAGE STAND SHIELDING 840705 009383 D35E002 SHLD HEAD STOR STAND 5 CN 0.780 9.65 STAGE 8' WATER COLUMNS 840707 009396 D35E002 SHLD HEAD STOR STAND 24 UM 2.214 46.83 INSTALL HEAD STORAGE STAND SHIELDING 840709 009401 D35E002 SHLD HEAD STOR STAND 6 CN 0.767 13.23 FILL 8' WATER COLUMNS 840713 009444 D35E002 SHLD HEAD STOR STAND 4 CN 0.362 6.58 MOVE AND RIG WATER COLUMNS 840716 009456 D35E002 SHLD HEAD STOR STAND 10 CN 1.069 20.20 FILL 8* WATER COLUMNS 840716 009461 D35E002 SHLD HEAD STOR STAND 47 UM 4.704 105.07 INSTALL HEAD STORAGE STAND SHIELDING 840716 009474 035E002 SHLD HEAD STOR STAND 57 CN 8.064 110.35 FILL 4* WATER COLUMNS WITH SAND 840721 00W510 D35E002 SHLD HEAD STOR STAND 94 CN 11.560 189.02 FILL 8' WATER COLUMNS WITH SAND 840723 009520 035E002 SHLD HEAD STOR STAND 3 UM 0.139 2.87 INSTALL HEAD STORAGE STAND SHIELDING 840820 009725 D35E002 SHLD HEAD STOR STAND 1 MM 0.165 3.52 ROUTINE CRAFE OPERATIONS 840820 009728 D35E002 SHLD HEAD STOR STAND 14 CN 1.200 21.67 CUT UP AND REMOVE 8* WATER COLUMNS a 840911 009881 D35E002 SHLD HEAD STOR. STND 18 CN 2.461 32.32 REMOVE SAND FROM REACTOR BUILDING

[$. SUBTOTAL - EXP-TRCK NUMBER. D35E002 PERS ENTRG. 384 EXPOS REM 46.442000 RWP HOURS. 769.80000 .820513 003843 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.154 1.73 MEASURE MISSILE SHIELD GAPS / PHOTOGRAPH

  • 820513 0038A3 D41C001 IN-CTMT RAD SURVEYS 1 ES 0.200 1.82 MEASURE MISSILE SHIELD GAPS / PHOTOGRAPH 820513 003844 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.239 1.83 RADIATION SURVEYS OF RVHSS
  • 820513 003844 041C001 IN-CTMT RAD SURVEYS 1 ES 0.161 1.83 RADIATION SURVEYS OF RVHSS 820526 003949 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.334 2.50 REMOTE SURVEY OF

'B* D RING

  • 820526 003949 D41C001 IN-CTMT RAD SURVEYS 1 OP 0.300 2.42 REMOTE SURVEY OF

'B' D RING 820526 003952 D41C001 IN-CTMT RAD SURVEYS 2 OP 0.811 3 33 SURVEY AND INSPECT 'A' D RING VALVES

  • 820526 003952 D41C001 IN-CTMT RAD SURVEYS 2 CN 0.933 3 75 SURVEY AND INSPECT

'A' D RING VALVES 820603 003999 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.182 0.88 RADIATION SURVEY 820610 004042 D41C001 IN-CTMT RAD SURVEYS 1 CN 0.167 1.50 RADIATION SURVEY 820630 004192 D41C001 IN CTMT RAD SURVEYS 3 CN 0.613 5.83 DECON

  • B' D RING / REMOTE SURVEY OF D RING
  • 820630 004192 D41C001 IN-CTMT RAD SURVEYS 1 ES 0.095 1.62 DECON

'B' O RING /9 EMOTE SURVEY OF D RING

  • 820630 004192 041C001 IN-CTMT RAD SURVEYS 1 HP 0.120 1.30 DECON

'B' D RING / REMOTE SURVEY OF D RING 820702 004200 D41C001 IN-CTMT RAD SURVEYS 3 CN 0.048 8.00 ERECT /RMVE SCAFF/INSTL TUBING.INSTS/ TEST

  • 820702 004200 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.005 2.67 ERECT /RMVE SCAFF/INSTL TUBING.INSTS/ TEST 820707 004229 D41C001 IN-CTMT RAD SURVEYS 1 ES 0.180 1.83 REMOTE SURVEY OF

'B' D RING $820707 004229 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.160 1.83 REMOTE SURVEY OF 'B* D RING 820710 004250 D41C001 IN-CTMT RAD SURVEYS 2 CN 0.008 3.67 INSTALL PRESSURE TAP 820712 004283 D41C001 IN-CTMT RAD SURVEYS 3 IC 0.005 6.00 MARK CABLE FOR QUICK LOOK CAMERA

  • 820712 004283 041C001 IN-CTMT RAD SURVEYS 1 CN 0.000 2.00 MARK CABLE FOR CUICK LOOK CAMERA 820806 004448 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.007 0.50 AIR SAMPLE AND GENERAL SURVEY

DATE 022186 PAGE 19 PNO 18 .TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS. DEPT EXPOS RWP.

  • DATE... NUMBER.NUMBER..........IVITY

... ODE. .... U. R S.............................E.SCRIPTION ACT ENTRG C REM HO TASK D 821216 005339 D41C001 IN-CTMT RAD SURVEYS 1 CN 0 118 1.93 RX VESSEL INTERNAL RADIATION MEASUREMENT 821216 005339 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.135 1.63 RX VESSEL INTERNAL RADIATION MEASUREMENT 830209 005783 D41C001 IN-CTMT RAD SURVEYS 1 OP 0.100 1.35 CLOSE VtNT VALVES - OTSG A & B 830209 005783 D41C001 IN-CTMT RAD SURVEYS 1 HP 0.222 1.75 CLOSE VENT VALVES - OTSG A & B . SUBTOTAL - EXP-TRCK NUMBER = D41C001 PERS ENTRG. 34 EXPOS REM. 5.2970000 RWP HOURS. 63.500000 820805 004442 D41C002 CHECK HIGH PT VENTS 1 HP 0.101 1.50 RAD SURVEY OF GENERAL AREA /RCS SAMPLES

  • 820805 004442 D41C002 CHECK HIGH PT VENTS 2 CN 0.149 2.50 RAD SURVEY OF GENERAL AREA /RLS SAMPLES 821020 004943 D41C002 CHECK HIGH PT VENTS 1 HP 0.154 1 85 RADIATION SURVEYS /RCS AND CRDM SAMPLES
  • 821020 004943 D41C002 CHECK HIGH PT VENTS 2 OP 0.115 1.73 RADIATION SURVEYS /RCS AND CRDM SAMPLES

. SUBTOTAL - EXP-TRCK NUMBER = D41C002 PERS ENTRG. 6 EXPOS REM. 0.5190000 RWP HOURS = 7.5800000 .820603 003998 041C003 CROM TOOL INVENTORY 2 CN 0.165 2 67 INVENTORY CRDM TOOLS . SUBTOTAL - EXP-TRCK NUMBER = D41C003 PERS ENTRG. 2 EXPOS REM 0.1650000 = RWP HOURS = 2 6700000 820610 004041 D41C004 N-2 SYS ACTIVITY 1 OP 0.227 2.42 NITROGEN SYSTEM OPERATION TEST

  • 820610 004041 041C004 N-2 SYS ACTIVITY 1 HP 0.235 2.50 NITROGEN SYSTEM OPERATION TEST 820610 004044 D41C004 N-2 SYS ACTIVITY 1 OP 0.014 2.00 INSPECT NITROGEN SYSTEM e *820610 004044 D41C004 N-2 SYS ACTIVITY I CN 0.025 2.17 INSPECT NITROGEN SYSTEM Ch 820707 004225 041C004 N-2 SYS ACTIVITY 4 HP 0.080 6.08 INSTALL INSTRUMENT TUBING
  • 820707 004225 D41C004 N-2 SYS ACTIVITY 6 CN 0.179 16.25 INSTALL INSTRUMENT TUBING 8
  • 820707 004225 D41C004 N-2 SYS ACTIVITY 2 QA 0.046 5.25 INSTALL INSTRUMENT TUBING
  • 820707 004225 D41C004 N-2 SYS ACTIVITY 1 OP 0.010 0.75 INSTALL INSTRUNENT TU3ING 820707 004230 D41C004 N-2 SYS ACTIVITY 5 CN O 775 9.17 NITROGEN SYSTEM HOOKUP 820709 004241 D41C004 N-2 SYS ACTIVITY 4 CN O 005 6.04 INSTALL & TEST NITROGEN TUBING-305'ELEV
  • 820709 004241 D41C004 N-2 SYS ACTIVITY 1 QA 0.003 1.33 INSTALL & TE ST NITROGEN TUBING-305 'E LEV 820709 004243 D41C004 N-2 SYS ACTIVITY 1 C2 0.015 4.17 INSTALL & TEST INST TUBING & INSTRUMENTS
  • 820709 004243 041C004 N-2 SYS ACTIVITY

) HP 0.055 11.00 INSTALL & TEST INST TUBING & INSTRUMENTS

  • 820709 004243 D41C004 N-2 SYS ACTIVITY 11 CN 0.169 27.66 INSTALL & TEST INST TUBING & INSTRUMENTS
  • 820709 004243 D41C004 N-2 SYS ACTIVITY 2 QA 0.030 7 25 INSTALL & TEST INST TUBING & IN ST R UME NTS
  • 820709 004243 D41C004 N-2 SYS ACTIVITY I OP 0.010 1.42 INSTALL & TEST INST TUBING & INSTRUMENTS 820713 004285 D41C004 N-2 SYS ACTIVITY 2 HP 0 000 14.00 HOT TAP MS BLANt FLANGES
  • 820713 304285 D41C004 N-2 SYS ACTIVITY 9 CN 0.000 62.42 HOT TAP MS BLANK FLANGES 820714 004299 D41C004 N-2 SYS ACTIVITY 3 CN O 005 3.17 REMOVE SCAFFOLD FROM nISTINGHOUSE VALVE 820714 004300 D41C004 N-2 SYS ACTIVITY 2 CN 0.010 1.95 REMOVE SCAFFOLD FROM ANNULUS HALLWAY 820719 004326 D41C004 N-2 SYS ACTIVITY 1 HP 0.000 6.67 HOT TAP MS BLANK FLANGES
  • 820719 004326 041C004 N-2 SYS ACTIVITY 6 CN 0.000 24.83 HOT TAP MS BLANK FLANGES 820727 004371 D41C004 N-2 SYS ACTIVITY 1 HP 0.000 6 00 HOT TAP MS BLANK FLANGES
  • 820727 004371 D41C004 N-2 SYS ACTIVITY 3 CN 0.005 15 42 HOT TAP MS BLANK FLANGES i

830106 005493 D41C004 N-2 SYS ACTIVITY 1 HP 0.228 1.70 CONNECT N-2 TO 'A'&'O' VALVE LINE-0TSG B

  • 830106 005493 041C004 N-2 SYS ACTIVITY 3 OP 0.4 11 5.43 CONNECT N-2 TO "A'&'D' VALVE LINE-0TSG B

. SUBTOTAL - EXP-TRCK NUMBER = D41C004 PERS ENTRG. 80 EXPOS REM. 2.5570000

DATE 022186 PAGE 20 PNO. 19 .TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D DEPT EXPOS. RWP. TASK DESCRIPT . RWP .EXP-TRCh. PERS. CODE .......,..........................I.ON

  • DATE...NUMBE.R

.......... I. V I T Y...............ENTRG.....E.M . HOURS. NUMBER ACT R RWP HOURS. 247.05000 .820610 004039 041C005 ELECTRICAL SUPPORT 3 CN O 298 4.25 INSTALL EMERGENCY LIGHTING FOR RVHSS 820714 004278 D41C005 ELECTRICAL SUPPORT 3 CN 0.322 3.38 INSTALL EMERGENCY LIGH7ING 821229 005430 D41C005 ELECTRICAL SUPPORT 6 CN 0.225 1J.50 TEMPORARY POWER INSTALLATION 830104 005462 D41C005 ELECTRICAL SUPPORT 3 CN 0.465 4.95 ERECT SCAFFOLDING-ELEV 319' 830105 005476 D41C005 ELECTRICAL SUPPORT 2 CN 0.188 4.18 TEMPORARY POWER INSTALLATION 830204 005746 D41C005 ELECTRICAL SUPPORT 4 CN 0.475 4.98 TEMPORARY POWER F OR HIGH REACH INSPECT'N 830823 007302 041C005 ELECTRICAL SUPPORT 2 IC 0.081 1.92 INSTALL COAX CABLE FROM RVHSS TO CCT-18 831018 007787 041C005 ELECTRICAL SUPPORT 4 CN 0.503 7.18 INSTALL REFUELING CANAL LIGHTING

  • 831018 007787 D41C005 ELECTRICAL SUPPORT 1 RP 0.033 1.10 INSTALL REFUELING CANAL LIGHTING 841126 010353 D41C005 ELECTRICAL SUPPORT 1 MM 0.003 6.72 INSTALL NEW CABLE & CONDUIT FOR MOD FTS
  • 841126 010353 D41C005 ELECTRICAL SUPPORT 12 CN 0.031 19.63 INSTALL NEW CABLE & CONDUIT FOR MOD FTS 841203 010395 041C005 ELECTRICAL SUPPORT 16 CN 0.031 29.82 INSTALL NEW CABLE & CONDUIT FOR MOD FTS 841214 010476 D41C005 ELECTRICAL SUPPORT 4 CN 0.361 7.03 INSTALL NEW CABLE & CONDUIT FOR MOD FTS 841217 010483 D41C005 ELECTRICAL SUPPORT 4 CN 0.306 5 58 INSTALL NEW CABLE & CONDUIT FOR MOD FTS.

. SUBTOTAL - EXP-TRCK NUMBER = D41C005 PERS ENTRG. 65 3.9220000 EXPOS REM = RWP HOURS = 114.22000 .820714 004279 D41C008 VENT & FILL S/G 7 OP 1.684 10.43 VENT RCS/ PROVIDE N-2 BLANKET / VENT OTSG A

  • 820714 004279 D41C008 VENT & FILL S/G 4 HP 0 729 6.75 VENT RCS/ PROVIDE N-2 BLANKET / VENT OTSG A
  • 820714 004279 D41C008 VENT & FILL S/G 1 CN 0.082 0.37 VENT RCS/ PROVIDE N-2 BLANKET / VENT OTSG A 820715 004287 D41C008 VENT & FILL S/G 1 OP 0.087 0.83 VENT RCS/ VENT OTSG A
  • 820715 004287 041C008 VENT & FTLL S/G 1 HP 0.025 0.17 VENT RCS/ VENT OTSG A 8

VENT & FILL S/G 1 OP 0.090 1.00 VENT HIGH POINTS h,$*820719004321D41C008-820719 004321 D41C008 VENT & FILL S/G 1 HP 0.088 1.33 VENT HIGH POINTS 821228 005420 D41C008 VENT & FILL S/G 1 OP 0.100 1.23 VENT OTSG A

  • 821228 005420 D41C008 VENT & FILL S/G 1 HP 0.052 0.67 VENT OTSG A 821230 005439 D41C008 VENT & FILL S/G 1 OP 0.050 0.58 VENT OTSG A - SECONDARY SIDE

. SUBTOTAL - EXP-TRCK NUMBER = D41C008 PERS ENTRG = 19 2.9870000 EXPOS REM = RWP HOURS = 23.860000 .821219 005366 041C009 IN-CTMT SHIELDING 3 OP 0.573 7.05 DECON PLUG SHIELD / COAT FLOOR DRAINS

  • 821219 005366 041C009 IN-CTMT SHIELDING 1 HP 0.180 2.28 DECON PLUG SHIELD / COAT FLOOR DRAINS
  • 821219 005366 041C009 IN-CTMT SHIELDING 1 CW 0.221 2.32 DECON PLUG SHIELD / COAT FLOOR DRAINS 821221 005380 D41C009 IN-CTMT SHIELDING 1 HP 0.135 1.00 HP SURVEY / TRASH ret 4 VAL 821230 005437 D41C009 IN-CTMT SHIELDING 2 OP 0.067 1.28 LEAD & PLYWOOD SHIELDING OVER FLR DRAINS
  • 821230 005437 D41C009 IN-CTMT SHIELDING 1 UM 0.025 0.75 LEAD & P1YWOOD SHIELDING OVER FLR DRAINS
  • 821230 005437 D41C009 IN-CTMT SHIELDING 1 CN 0.031 0 75 LEAD & PLYWOOD SHIELDING OVER FLR DRAINS

. SUBTOTAL - EXP-TRCK NUMBER = D41C009 PERS ENTRG. 10 1 2320000 EXPOS REM = RWP HOURS. 15.430000 . 810427 000967 D41C011 VENT & SAMPLE RX GAS 3 CN 0.013 5 58 SAMPLE REACTOR BUILDING ATMOSPHERE

  • 810427 000967 D41C011 VENT & SAMPLE RX GAS 1 HP 0.000 2.50 SAMPLE REACTOR BUI13!NG ATMOSPHERE 810511 001046 D41C011 VENT & SAMPLE RX GAS 2 HP 0.002 7.00 SAMPLE REACTOR BUILDING ATMOSPHERE 810523 001117 041C011 VE N T & SAMPLE RX GAS 5 CN 0.008 20.67 SAMPLE REACTOR BUILDIFG ATMOSPHERE 810613 001265 D41C011 VENT & SAMPLE RX GAS 1 CN 0.005 4.83 SAMPLE REACTOR BUILDING ATMOSPHERE 810613 001265 D41C011 VENT & SAMPLE RX GAS 1 UM 0.000 4.33 SAMPLE REACTOR BUILDING ATMOSPHERE

.;tt s DATE 022186 PAGE 21 h

  • 20

.4 't# 1' ?#$.,.' , Y, UNC. DDs - ACTIVITY REPORT - REACTOR DEPudL &'d!$ASSEHGLY M 2f 6 D I 'TM / I-2, < gwp l, f. E x p.T RCK. e PERS '. DE PT E#POS. 'RWP i i " I

  • t I r' '

t SATE

  • e e s s e;. NUMBER.. NUMBER '. s

.4=e==,ACT.IVITY? ' . ENTRG.. CODE *. iREM s. HOURS. ..L.s,, e ' TASK e s-.. = = = = = = = = = = = ( e o*= = = e. = = e s s e. s e * = e.e.. = = = =. *

  • e e s e.s a s e d d e s s e s, D E SCR I P TI.ON,e==

s:een... .este==' t<eesse. veeeewe(e=====

  1. 10613 00$2'S'S 04%C011 VENT 4. SAMett :RX GAS I HP' O.000

'3.70 SAMPLC REACTOR '8tf!LDINGIATM0 SPHERE seene..

  • t2081 004483 041C0$1 VENT 4' SAMPLE'RX GAS 1 MK Q.1 2 t1 43 CRDM, GAS,SAMP E'AND.WEMQVAL, l.,, g lp. -

CRDM

  • 82081 004489 D41C0!! VE NT 4: SAMPLE '.RX GAS

'l HP 0.1 1 't.58 GAS.SAMP E AND REMQVAL T

  • 82083 004644 D4tC011 VE NT 4 SAMPLE '.RX GAS 2 HP 0.3 1 3.87 f

'ANDREMOVAthl~.,U'i CRDM ' gap: GA SAMR E lAND. REMOVAL 48{0914004702D41C011c8?c 004 04 04tcott VENT &.SAMPtt'.RX GAS 4 CN 0.59T 5.60 gA000RVET/RCS(t IQtJID 4 ' GAS SAMPLES PDM SAMPL J

?/

'8. VENT &; SAMPLE

  • 3 Hfr 0.377

. 4. 4 2. e ' VE NT &,' SAMPLE (R X GAS

  • 82091t 004 M 7 041C011 RX GAS 1 OP' O.220

,'2 83 RAD'. SURVEY /RCS LIQUID 4 GAS SAMPLES

  • 820922 004R$2 041C011 VENT 4.SAMPLETRX GAS 2 09 0,254 2.55 RADistRVE YlRCS. LIQUID A -CAS SAMPLES c,

. 82 922 004712 041C011 VENT 4: SAMPLC '.RX GAS 4' HP: O.737 14.98 I RCS GAS 'SAMPtt [AND ' REMOVAL * ' RAD /SURVE t/R 82 928.00480'$ 041C011 VENT-4 SAMPLEGRX GAS 2 OP' O.377 ~5.67 .S0 CTAt.- EXP-TitCil.NUMBE i D41C0!! Ed=di19go000, RSs f M4 t Pf, Me i 'liC$Ys 0YECTiSti U S tS W tMENTATION l' dM Q.130' 1.50' !!di G EAnidiididdYE'dTodE* '

  • 8207I5004jSO,041C013 RAQ. IN$M UMEftTATION 1 HP 0.054 1.17.

IMTALC RADI ATIDBL* DETECTORS. ",

  • W8HIAF p EMCx MM 'i' led.0itC013

- i7

gg g

u 3 g ; n y t p gi m p MI400'oh E t n i P : m 8 C XPQS]6 t '_ C 0 % TEST IN8 Lmli %!;cM .E 9 RvP. SN !6200000 (t4!*!c?L 2T , 9 "S1'WU WT M '820119A 04C0j4 TOOL 8Id[htPMENT 4 Cff Q.751 9.50 0 S{AGEjcjDthdLS/INSTAhfuCTUBES Sggs cQ,y C,K M Q gpQCH4 jg Q " }$ hME EC DrE #$N C4 'I'T3POSM bt O'75'30d'04 itEcIPICAL N 0 10P -t PIFAIR ! TGN r@ i S - i RE,M { [820fl30 0041 Y 8 ' AWP FNO S N 255000000 ELECTFicAL ( r, c

85 3 ?{

ffFA!W t T OP. QI} ; (20036 00(1 4 04 C015< HolS f Midpfd{etATFORM ~ PLATFORM 2 Cff 0.2T[ 7(.52 155{dfL ROM MORK'PLATFCRM $3 I 1 04tC015 HOMST/ RIG 40/ 4 Cft 0.502 INSTALCI 20CL T&Ho1ST FVR,LDSCR. REMOVAL 821.03 005Q3'T 041C015 HOMST/RIGNQtPLATFORM 4 C4. 0.436 8.75 li1STAL IGH' IME ON ' P.C'..GI RDE R ' -N

  • s70.07 005507 04fC015 HOLST It!GffG/ PLATFORM 4 CM 0.579 6.5%

REPLA0,RVMS ADIST/1NSTALt;,HANDRAlt 830. 27 0051tga, D4gC015 HOIST RIGff0/PtATFORM 4 Cff 0'. S $0 6.68 RjPLAC,RVHSS y0IST$'"' 1; " ' ' ~ 'k hkyhg hN $ 3 bik k ab b )N d R E ddbt' ' I N L'L E 53 20 ri '8 820115 004189' 04{ht :360000MH0uRS }didi80d0O E L E C1R R AL POSC L -R EM ' CN a 097 ? PEPLA:1 M. t i / U.P lI tRWP ELECTRICAL Ei 115 ' l} ufftt.r,7kyt[3 L;;

:,y C016 VENT CI(DN"M.h 2 MM
0. 4 d

.92 Ydr$T,CRDMIOCTd{N, GAS"&'L'IQUtd'S MPLES E h "L

  • 820715'00(289 04}C0te' VENT CROM NICA 7 HP 0.394

.48 VENT':cRDM/0 STAIN CAS &.kLIQUID SAMPLES

  • 824715 00$289' 04tC016 VENT CROM
2. Cif 0.3T5 4.00 VEftT*CRDM/OSTAltt GAS & tIQUID SAMPLES 520730 004427 D4 C016 VENT QROM" D I
  • 8'2T7.3 044g304C016 VENT C

'ML 2 Qtt 0.278. 3.33 ONCAP/VlNT/ REMOVE:. SEISMIC. RESTRAINT 1 HP 0.090 1.25 ) uMCAP/ VENT /ptiMQVEQEIStjIC RESTRAINT l ~ .t bl Yhh kNbb5[k hbbi $ b P[Ni.P Lb kN gg '8txP tg P EU l01700'00 ELEGR D L 4 EL 4 m 7 % WJM SM & Pf9A!E P.C rm C1. - ida gwp C yq.3 e h6 ELECTRICAL 2 CN O IH 1 18 TPttDLESHOOT~ & PEPAiP f' FE'% CM*- Dl ' 55071p 004315' 64fC0f'980006 LD$COdfedddPt'ES PARK f OP

6. Nd d. 7'S V[ftTf[d5CdtiP d"$ 'P?ARhl'dADSCREW 7'

i

  • 120710 0043.19 041C017 LD$C b,VNC0det;E& PAR K 4 HP.

0.971. 7,92 VE N T, 'NfdC00 P &" P. ARK.'tE ADSCREW $820711 00 4 5 04~C017 L) CR a0NC00PLE& P AR K 1 ($' O. 100 1.67 VENT ',UNC0t{ Pt &" PARM ?tE ADSCREW

  • 820719 004~1 5 04:C0t7 L)

()MC0t4PLE& PAR K 3C 0.420 6.08 VE ftT,.1.tNCWPtf 4' PARK 'tE ADSCREW

  • 82'040 004'424 DEC017' L) yNCOUPLE& P AR tr 4 1 0.003
8. 17 DISCQfffiliCT ' POSIT 10N'lNDICATOR CABLES
  1. 29809 004441 0410017 LD UNC00PtES PARI 2E 0.313 3*.98 REMOVE-CRDM/UNC00PLE '8"PARM 'LE ADSCREW '
  • 820805 004441 041C017 LDSCR-UNCOUPLE & PARK 4 OP 1.321 6.83 REMOVE CRDM/ UNCOUPLE & PARK LEADSCREW e

( ;>, y ni e DATE 022186 PAGE 22 N 'i. PN0's-21 .-A-m' Ze" 'o1 kl. '* !4' 6: ' bl% 'l~" e t-t, 'RWRa ". E XP - TRCK. "C1IV1 ' - REACTOR DEFUEL & DEtASSEMBl.Y M 296 D 'T MI -J M UNC'" DOS - ACTIVITY REPORT I *, PERS DEPT EXPdS. 'PWP' -

  • 820805 004441*D41C017 LOSCR-UNCDUPLE& PARK.

..E.N T RG. CO-REM: HOURS ^. * ... w..t.., TA S. K.D.E.SC.R. I P..T I O. N......,. .s.."w.. J V I T Y '....*.*..*.*... .... D. E.. -ACT

  • .DA TE.'.; NU.MB.E.R..n.........

NUMBER' 11 07 RE MOVE ' CRDM/ UNCOUPLE &.PARF LEADSCRE9 ' 6~ HP* I'.250 REMOVE'CPDM/UNCDU#LE &'PARh LEADSCREW 48208051004441' D41C017-LDSC R-UNCOUPLE A P AR K 3 CN-1 101 5 17 820820 004549 D41C017i LOSCR-UNCOUPLE & PARK 3 OP-0.566 3.92 UNCOUPLE CRDH ' ' ; ~

  • $20820' 004549J D41C0171 LDSCR-UNC00P LE& P AR K 5' CN' O.843 7.25 UNCOUPLE'CRD4-L

'I LDSCR-UNC' 0PL E& PAR K 2 CS 0.233 4108 UNCOUPLE CRDM-821118 005131.D41C017i 0 &21122 005154 D41C017 LOSCR -UNCduP LE& PAR K 1 HP-0 05V 1.12 CONFIRM APSR UNCOUPLING - R0034'.

  • S21122 005154 D410017 LOSCR-UNCOUPLE 4 PARK 2 CN-0 127-T.98 CONF IRM APSR UNCOUPLI'lG A F0034 -, '

821208' 0052.744 D41C017 LDSCR-UNCOUPL E4 PA R K 2 ES-0.361'

54. 0 3 RAD' SURVE YS/APSR PARKING /LDSCR VERIF.
  • 821208 005274 D41C017'LDSCR-UNCOUPLE & PARK 2 HP 0.318 5.67 RAD SURVEYS /APSR PAWKING/LOSCR VERIF.
  • 821208;005274-041C017 LDSCR -UNC OU P LE & PAR K 4 CN 0.704 9.93 RAD SURVEYS /APSR PARKING /LDSCR VERIF.

821210"005 29 7' D41C017' ? LDSCR-UNCOUPLE & PARK 1 ES 0.156 2 43 LEADSCREW VERIFICATION

  • 821210 00S?97'D41C017 LDSCR-UNCOUPLE & PARK 1 HP 0.146 2.50 LEADSCREW VERIFICATION '

7

  • 821210 0052S7 D41C017-LDSCR -UNCOU PLE & P AR K 2-CN 0.321:

4.85 LE ADSCREW VERIFICATION-82-1213 005306.D41C0174 LDSCR-UNCOUPLE & PARK 2 ES O'266 4.35 LEADSCREW' VERIFICATION

  • $21213 005306-D41C017; LDSCR-UNCOU PL E& PAR K 2 HP' O.295 4 80' LEADSCREW VEPIFICATICN
  • t21213 005306-D4100171 LOSCR -UNCOU PLE & PAR K 4 CN-0.472 8.83 LEADSCREM ' VERIFICATION 830912 007452 D41C017' LD SC R -UNCOU'PL E & P A R K 1* E L) 0,088 1:70 INSTALL' HOIST UNDER MISSILE'. SHIELDS
  • 830912'007452-D41C017' LOSCR-UNCOUPLE & PARK 4' CN-0.388' Em78 INSTALL 7 HOIST'UNDER MISSILE SHIELDS 6310105007731.D41C017; LOSCR -UNCOUPLE & P AR K 2 FWC O'142-3.55 INSTALL' HOIST:UNDER MISSILE SHIELDS
  • 831010 007731:D41C017; LOSC R -UNCOUPL E S P AR K 14 CN 1.093 1 91 78 INSTALL NOIST VNDER MISSILE $HIELDS 431012 007748'D410017; LDSCR-UNCOUPLE & PARK 2 OP' 01170' 4.00 TRI Alc PARK 5 LE ADSCPEWSJ - ' '
  • 831012'007748'D4100171 LOSCR -UNCOUPL E & PAR K 2 HP-0.208 4 5 *J TRIA1' PAR &'5 LEADSCREWS
  • 831012 007 7 4 8 ' D41C017-LOSCR-UNC00PLE& PARK 3-CN' 01248' 5.95 TRI Al" P/JK' 5 L E ADSCR EWF ' '

8 431018 007792'D41C017* LDSCR ' UNCOUPLE & P AR K 1 OP 0.102l 2L77< UNPARK LE ADSCREWS ' LDSCR --UNCOUPL E & P AR K 1 HP 0.129 2.98 UNPARK LEADSCREWS "-. $' *131018 007792 D4100171 LOSCR-UNCO.UPLE& PARK

  • 831018 007792'D41C0174 1 CS 0:.130; 3t 00}

UNPA.RK LEADSCREWS f

  • I_

2 "4 ' '-' '^ t .SUBTOTALo h 5EXP-TRCK 14UMB E R-D41C017 '"4 d 'I 'i 'E ENTRG N L s

  • 93-LUAD it u J

"U ?: PERS v CM

  • S;RWP OHOURS M 174.420t0-LUAD i t,'

tL N3 > ' Cti , t E X POS 6 0 R E M E=P13 941000 L L%D R G'u CdAn iS4 6207.19' 0043161041C018; LE ADSCREW -CUTSD E MOVE 1: ESi 0.259 2!08 RTHOVE ' Anti CUT lt.E AbSCREW

  • 820719'004316 D41C018' LE ADSCREW-CUT & REMOVE 7 HP-0.502' 4 00 REMOVE AND CUT: LE A*> SCREW
  • 8207191 00431610410018; LEADSCREW-CUT & REMOVE 2:CN 01648-3;.92 REMOVE AND' CUT'LEADSCREW

$20806 004449 D410018; LEADSCREW-CUT & REMOVE 1 ES-0,310; 1.67' REMOVE ant 0 CUT LEADSCPEW

  • 820806'00444B>D410018: LEADSCREW-CUT & REMOVE 2 HP-0.718-3133-REMOVE 'AND CUT LE ADSCR EW
  • S20806iOO4.749 D41C018; LE ADSCREW CUT & REMOVE 2 CN-01905 3 33 REMOVE ' AND CUT t.E ADSCPEW S30706 00688& D410018; LEADSCREW-CUT & REMOVE 3 EL O'415 5.87 CUT 1E ADStPEWS/SE T UP CUTTING ARE A 740 12 +.10 CUT 1E ADSCREWS/SE T Up CUTTING AREA
  • e30706iOO6834"D410018; LE ADSCREW-CUT &R EMOVE 6 HP' 0. 0 % 13' 0'

1c37 CUT: LE ADSCREWS/SE T UP. CUTTING AREF

  • 830706 006884+D410018; LE ADSCREW-CUT & R E MOVE 1: Ft+
  • 83070&'006884JD41C018; LEADSCREWiCUT& REMOVE 19 CN-0'219 36*43 CUT LE ADSCREWS/SE T. UP. CUTTING ARE A 83071D 006909 D4tC018; LE ADSCREW CUT & REMOVE 2'HPN O'268-4'.03 CUT tE ADSCREWS
  • 6307115 006909' D4100181 LEADSCREW CUT & REMOVE 11MM' 0:140'

?! !? CUT'tEADSCREWS ~ 'f' '"U LL'" F-

  • S30711 006909 D410018' LEADSCREW-CUT & REMOVE 5 CN O'.831' 11!82' CUTitEAD$ CREWS

' $ - ;f T -'W" .SUBTOT AL-v v d 3 EX.A J t r 2P-TRCK NUMBER *. P41C018 ' : h 4' 'L F-3' M F* t c PM 5 0 ? 6 PE RS' 'ENTRGi

47 t um it' O

Zd' "E J 'A ? b EXPOS N REM L.4 6? O 3 6 0 00 0' LW T f 5' ila 3- 'H E E ^ ^ ~i' "' ' "6 ^ % " ' .?4RWP. Oh0URS M 82'0700'00' WD ME > 'i

  • 7t' I'

N S20721s004338 04tC019 ESTBLSHiEARMARK SYS 2i CN' 0". 5 0? - 4;100' REPt ACE'/Rf LOCATE' Rt.DIO' ANTEN'NA' #' 82073&;004420'D410b191 ESTBLSH> EARMARK SYS 2'CN) 0.1504 2 EARMARK RADIO MAINTENANCE .SUETCTAL - EXP TRCK NUM9ER = D41C019 - (

I DATE 022f86 'PAdE '23 iPNO. ?22 JT14I42 .iUNC. !DDS JACTIVfTYFREPONT ' FRE ACTOR'$EFUEL'& DisAS$fNBCY'N1286 D I E .kRWP tEXPlTRCK. 'P(RS. ' CODE. " A th. 4t0VRS.....'.. M

    • iOATE WUM8fR PNUMBER,

/AdTIVITY .IfNTRG.'OEPT.LCXPOS. 'PWP. I .,,. Td$K OE$dRIPTION....,. s 6 E R 4

  1. 4 ?E1POS C o
  • REM' 4= 'O i 6526000 (W !!ST 3

'N O 167 'l INSIAtt LOAb W A T I Y, ', l M W t RWP J O N00R $ 416 ! 7506000 LLAD IfrI a(-N O m ii A5StMULE AF M M I:M m M WM 182df36l004426tD410020 RICTLDSCR I TO dTO# AGE 3 CN 0 390 3.50 RIO LEADSCREW OFF RVHSS .SU$70TALEM b EXP-TRCl$ 1. NUMBER = 041C020 LPfR$ f mTRG 'a M S v #*3 )50 1 0 gs R CRANE 'M Ad CN 1 !]1 de 15 AU>r F0151 LLAD rg ;T E820Tf9 LOO 43344041 621 IhCORf TV iM$PECTION 1 IC 0.000 1.50 MARK CABLE FOR QUICK LOOK CAMERA JOB

  • 826719 004734: D41C021 INCORE TV INSPECTION 1 CN 0.008 1.50 MARK CABLE FOR QUICK LOOK CAMERA JOB 820721 004339 D41C02)6INCORE TV INSPECTION 4 CN 0.676 9.67 INSPECT UPPER END FITTING OF FUEL ASS'Y
  • 8267-11 O t43M D4100110 C INC O R TV NSP CT :0N

,2 HP 2H3 ,3.25 ':NSPEQI UPPER ND E ITT.'NC 28201110004 319 (041CO21 ftNC6R LTV Ns# Ct :0N il p I, f IJO ',0 : 0 0 ON$PECT OPP ND PITT:, OF FutL ASS *Y

  • 530721C004339 D41CO21 EINCCR LTV NS# $t :DN Itts

! 11 5 '1.J6 7 %N$PEC3 OPIL MQ(FITf:'fth !DP FUCT, LASS *y L NO Q d VEL ASS *Y

  • i820 721 COS4340 CD41C021 IINCOR LN N# CTMON 12 TC

'O 720

  • 2:80 ASE'T WP CAMf

' M RVH3$ AND TEST

  • 8207?fst004340E0410621 INCORt TV MS PEC T ION 1 CN 0.120 1.33 SET UP CAMERA DN RVHSS AND TEST 826730 064422> D41CO21 INCORE TV INSPECTIGN 1 CN O 117 1.58 RELOCATE VIDEO EQUIP FOR QUICh LOOK-2 820736 004443 D41C0214CINCORE TV INSPECTION 2 IC 0.333 2.83 STAGE & TEST VIDEO EQUIP ON RVHSS

$820730 Ot4443.D41CO21P INCORE TV INSPECTION 1 CN O J48 1,42 AGE .TE V VIDEO EQUIP. ON RVHSS y E S30 844 0054440 !D41C021 FINCOR OITV CINSPECT ION '6'CN C1 f497 (1;59 C11 OM :: K Y.M$PECT! N,& ' CORE PROBENSPECP10M & TDRE

  • PRO
  • 870804C054440ID41CO21 f fNCCROITV CINSPECTION 1 CR C0 117

-1 08 C 2

  • 810804C004440!D41C021 FINCORE ITV CINSPECTION S2 MP

% ;>314 1,'4,33 t, IN PECT N I W ORE PRC80 "I. 6 8 t0 812 00544 7 8 :041C021 f!NC OR C ITV c fNSPECT ION 1 92f!C 4 M49 13.!3 9 'SIA AME ft A' 'E PME NT' ' 'd

  • 820812C0844F8LD41C021 'INCORE ITV CINSEECTION 43(CN f0 j401 < 4 f 95 6$TAGE &

3 18 20 812 COS44 80 tD41CO21 ITNCOREITVCINSPECTION '3'CN (0 #$9 158.00 ' CORE PH MEHA E PMENT (!DE0"I PECTION G 28108I2 t004450 LD41CO21 f fMC 0RO ITV CINSPFCT ION 41(CR %.0249 2:90 'QORO YROSE tANM'VIDEQ 'INSPECTI0ff %' 2820.812C004480fD41CO21 ffMCOR0ffVCINSPECTION 7 L f 70 l 3523 fo !'247 1 }~2 c5 8 ' OR E. PR OBE A'NQ V f DE0 '1 NSPE'C T 10T WL 1 MP 3820E120004480(041CO21 f TNCORO ITV CINSPECT ION t,I ((s b s,2 Q? @.* *0BE D[ g,.ID Q 61NdPECTIgft.,-. 'g 3 ISUETOTAUIN Z LEXP+TRCK f ~ NUMBER f is 0410021 uN O 15 3a i e t t i> 2 mt - ie 3 MPERS 01.EffTRG 'e f 001 F 137 M@ I F ICA i 10% 19 CN O 947 % Fi INSTALL UPINDfFt.. ALIGN N 06ILL 25 EXPOS 11 JtEMild r514350000 MODif !C A T IONS 2 CN 0 "89 1 3' REMNE 2 FH W ID 'd PAIL SIDFS 2 50 RWP 01: HOURS ?4 f 89 590000 MCDIF IC A TIONS 3 CN 0 J25 7 J3 IERMINATE CAGtE #9 + 75 '82077Fl004337 tD41CO22 INCORE LIQQTO FSAMPL E 1 HP 0.125 6.17 RCS LIQUID SAMPLE

  • 820721 004J37iD41C022 INCORE LIQUID SAMPLE 4 CM 0.457 2.08 RCS LIQUID SAMPLE 820727i004375 D41CO.220(INCORE LIQUID SAMPLE 1 HP 0.140 2.33 RCS LIQUID SAMPLE
  • 820727 004375 D4 LCO27 7CINCORE LIQUID SAMPLE 2 CN 0.406 4.50 3 CS. tiquity '>SAMPitRCS L,1 QUID.S AMPI,E, M F8:20802 $04424 TD41CO22 f!NCORE 4IQUI5'5 AMPLE 4 t09 (0.1150 71 A2 M I '/ t..
  • 820207 tOQ4424 LD41CO22 FINCORiw ti! QUI 5 'SAMP LE

'1 (CM FC.418 1 1.42 'FC S' OyID SAMPLEJ ?- I f' U L L L ' b. Nt2G812 t004477 ID41CO22 FINCOR.EH1110015 55 AMP L E '2 0P '0 l331 '3.45 40$- QUID SAMPLE CI#IUL #ET' / I

  • 820812tGQ447.7!D41CO22 'INCDREvtIQUID '5 AMP LE

^1 WP f0 ^142 '2 D3 MCS QU.IOPSAMPtf R fH WIE M h82G907(Q04055(D41CO22 FINCOREdli!QUIOUCAMPLE 41 cop e pt:20 50l92 !R CS> 070 SAMPt,EVdDM' GAS SAMPL'f NVAL c T 4820907 4G4655:D41CO22 f!NCOR.E WIQUIDGAMPL E 6 '2 WP 'O 4264 P 23 01 4tC*

  • 820SG7 ma4655 ;D41CO22 f!NCOROWIQUIS'EAMPLE F 1 '.CN 4 t128 F11f35 IRCd IDq(SAMPLE /CRDF ID SAMeLE/CRDF AS 'SAMPtic
SAMPLE, A$

"320E28 ta4802,D41CO22 IINCORE 4IQUI> 'EAMP L E 2 7 WP ~0."361 6 4.*33 [R @,I.OIJF SAMPLE /CRDV AS'SAMPLff UQ

  • 820G28 00:0'4802 (D41CO22 FINCOREGIOL!!DWAMPLE l'1'OP TO f150 22.00 FRCS WIQtHO SAMPPfyCPDM GAS SAMFLE d

I '821'00S t00 4 55 7 iDJ1C022 INCORLf LIQti!n4 SAMPLE 1 HP 0.175 2.00 RCS LIQUID SAMPLE /CROM GAS SAMPLE

  • S21006 004E % D41C022 IINCORE LIQUID SAMPLE 1 OP 0.168 1.93 RCS LIQUID SAMPLE /CRDM OAS SAMPLE 821011004896 D41CO22 RINCORE LIQUID SAMPLE 1 HP 0.132 1.58 RCS LIQUID SAMPLE
  • 821413 004898,D41CO23E INCORE LIQUID SAMPLE 1 OP 0.120 1,50 RCS LIQUID SAMPLE 882.110'3 MI5G32,D4kCO22 f1NCOREAVIG)1D 'SAMPLC

!! WP t0 7141 71193 iRCSAIQUID'fSAWLi!/CROM ' GAS 3 AMPLE ~

DATE 022186 PAGE 24 PNO 23 .2 - < c1 W .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 0 RWP .EXP-TRCK. PERS DEPT EXPOS. RWP. ..AUMe E R. NUMBER. ACTIVITY ENTRG CODE. REM. HOURS. TASK DESCRIPTION

    • DATE
  • m a.e a = * *seaem;esaeayem,aeg,erazy== age,masaaa pr-a gs p vg sie.a.e e o, o g m;s p e t, g g a e e m ; m W s y a e, a e a a e =, e a o e a e e e a e e e e e a e = e e e e a s a e e s e e e a a e a e e e e e e 4821101 005032 D41CO22 INCORE' LIQUID SAMPLE

, t,1 OP t > : 0a118. h30 RCS LIQUID SAMPLE /CRDM GAS SAMPLE .821117 005127 D41CO22 INCORE 11001D SAMPLE t s i 1,OP m s 0.135 lugs RCS LIQUID SAMPLE /CRDWGAS' ' SAMPLE 4321117 005127. D41C022 INCORE LIoulb. SAMPLE -2 HP-0.356-s4.90 .RCS -LIQUID i SAMPLE /CRDM GAS SAMPLE 821124 005183 G41CO22 INCORE,L100, SAMPLE 1 HP 03250? 2;07 RCS;LloVID SAMPLE / TL: .fA6.'r INCORE;41

ltOP, 0,007 1242:

RCS vL IOUID: S AMPLE /. ,ILli.> INCORC', IOU.ID[ SAMPLE

  • 821124 005183 04.1C022 INCORE: 1061 SAMPLE.

1: HP O;190 2i65-RCS' LIQUID: SAMPLE /CRD*t GAS : SAMPLE &21202 05213 041C022 i

SAMPLE, 1 0P.

Oil 3 2il5 RCS L10VID4 SAMPLE /CRDtt GAS -SAMPLE - (821202 05223 04fCO22

  • 821208 05272 04CO22, INCORC,1001b, SAMPLE.

8212C8 0527.2 04fCO22 INCORC 1-HP O,2 7, 2;43 RCS $10VJD SAMPt.E Vw : r: 11QLFIQ3;5AMFKE l' OP 0.0 1 1.37 RCS LIQUID $ AMPLE .SOBTOTAL n.. n EXP-TRCK RUMBER = D41CO22 M R S -. t aft tG'. 35', ,,s E #0S, REM r =: 5,,2630,000 .,.. RW P 820817 6.,HOM SU 6L 990Q03 nC1,0SEl l1D.CROM 1 ^. Hh. - - 163: 1.392. Rdf &cCRDM. SAMPLES /CLOSE.CROMt ' ; y. 0]322. 1 eri't r. 3 -t -*,. i - 045h7 041 023 c-~ t>twp 4 g,,g. (8208170045J 04 023 Ct,CSE U.P CRDM g,iy 2,CN; 0 3;75 RCS,4;CRDM -SAMPLES /CLOSE, CRDM.: CL,0SE 3 HP 0 '4,552 6.27. CROM,CI0 URE/RCS; SAMPLE, n ,y, '821 4 MM' O.811. 9;94 CRDM,CLO)2URE/RCS SAMPLE CL,OSE,UP CROM<,7 J' 820820 004Sa7 041 023 UP'CROM 5'CN 0,862; 820 00454T 041 023

  • 82g;208 00$271041CO23 CLOS,UPICRDM[,Th[

, s

y 9,97 CROM MOTC8 51U8E S.Closua E.

I: 8212}4 005320 04LCC23 CLOS UP'CRDM 2;MM 0.235, 3.22 CROM MOTCA sTUSES CLOSURE o 4821214 00$T24 D41CO23 CLOS UP QDM r '.. 2JCN' 0l. 220 y588-CROM MOTOR t,UBES Ct050RE # g i;4 e r,, g ,kUM8tRf y $ fafkt 4 Ci '9 M' W D4 LCp 2,3.l ' p, a e.

c. E t up t o.u ' N T

.M >, i i fyB T O T At, ;(;-7 7f ' MTRG =,PgTRCKT 00dc4 3 X IQc PERS F C i t '.T N i WA A 0 g ':HQURS. =j j7 g RD1 s , 9 E X POS 7 c , 7 1 .' a ; m, 7 ; t m,, 3 mgp,nv 3 n im

R'N P 7mS9000d f& 7I N.,.,,;

<..- me ...,u. ,.,;s VENT-R CS. 1l0P' 0,196: 1 85 L RCSc L100fD. SAMPLE'/RCS REFILL' E-M21218 005378 041 024 VENT 4 TILLI RCS,. ' g ; i, A l ' HP. 0.150 1;90 RCSc LIQUID,,$ AMPLE /RCS METILL f *'82221tL 005138. D41 024 RCSiREFILLr;6 ;.. 1-- 821217 0053P D4 024 VEN{ '& F Ill/ RCS'. y 1:HP' 0,231' 2:07-3 m 3 eit

  • 82I217 005 d 04 024 VENT- & T IL1' RCS, y f:

l ' OP. 0.213., 2.02' RCS ; REFILL v <- r '82!22d 005102.041 024 VENT & TILL RCS,/ 1: HPn 0.0TO 1,13 RCS cREFILL/CRDM INSPECTION ' f$UBIOTAL'W "" PE RS "' F NT.RG (4 T3Ctt NUMBE.R{Iti;RCS ;<.3,q41CO24' Da048; 1*.32 RCS,REFlLL.INSPECTIO4;g 82122t 005178 04 024 VENT & 1 QA. ~ E

  • 9

~ a S. r EXPOS REM ' i O. 9 4 8 0000; tRWPs hoods. i 10 220000 .821Ito. 005081 041CO25 s RMOV.LDSCR FROM CTMT 3 HP. 0,541 8,12 MOVE.LEADSCREWS.TO 'B'.D-RINGe, .i -

  • 821110'005061 D41C025. RMav'LDSCRffROM CTMT 5'CN:

0,8247 13;15 MOVE. LE ADSCREWS :TD ~/ B},D-RING :

    • 21[10' 005082 D41CO25 RMOV LDSCR ; F P OM CTMT 5'RP~

0:678' 9.23' LEADSCREW'CUTTINT* 421I12 005092 '041CO25D41CO25BRNOV,:LDSCR' FROM CTMT 5 CN 0.738 8.83 SET UP LEADSCREW CUTTING AREA 821115 00S(09 RMOV LDSCR FROM CTMT 2 HP 0.324 5.00 CUT LDWER HALF OF LEADSCREW H8

  • 821115 '005109' D41CO35 ; ~PMOV LDSCR FROM CTMT 6 CN 0.949 16.22 CUT LOWER HALF OF LEADSCREW H8 821115 005113 D41C025'"RMOV LDSCR FROM CTMT 4 RP 0 010.

3.,75 TRANSPORT, LEADSCREW SAMPLES & PACKAGE.

  • 821115' 005113 D41CO25 RMOV 'tOSCR Fh0M CTMT 110 0 O j o 0 0 '.

0.73' TR AN$ PORT 'LEADSCREW SAMPLES & PACKAGE.

  • 821117 005137 041C025 RMOV [DSCR FROM CTMT 1: RP' 0,005 1/72' PACKAGE LEADSCREW FOR SHIPPING 821119' 005148 D41CO25 RMOV 1DSCR FROM CTMT 3JHP Ol031. 5 '. 8 8 L GAMMA SCAM OF:.LEADSCRIM SECTIONS.
  • 821115 0C5148' 041CO25 RMOV 10SCR FROM CTMT 3 CNN 0/116-8(63' GAMMA SCAN.OF.LE ADSCREW SECTIONS

+821122 005L63 041CO25 RMOV LDSCR FROM LTMT 1.CN-0.0171 4:73-GAMMA' SCAN iOF: 1E Af> SCREWS 2821122'00SL68 041CO25 RMOV'LOSCR FROM CTMT 2.RPa O' 0' 4/70 PACKAGE-LEADSCREWS FOR, SHIPPING,

  • 821122 0G5168 D41CO25. RMOV LDSCR F ROM CTMT 11HP" C

Si 2/73' P ACMAGE" LE AD9 CREWS F ON SHIPPING - DECOM TEST & 'LE ADSCREW M8 '" 5821211005326 041CO25 RMOV LDSCR FROM CTMT 7 H9N O $' 16:58' D&COM TEST :0F: ' LEADSCREW H8 38212L3 00S326 D41C025 RMOV 1DSCR FR'OM CTMT SIES' 0?418 13)20' v h. % =Ds1MM c., n :.1 : n Ese ' tt ^ e i FEk5 ENT4 2 [AF C "., &[M- " 1 i', -l C a

_?

s3 :

DATE 022186 FAGE 35 PNO. 32 .TMI-2 UNC DDS - ACTIVITY REPORT - REACTOR DEFUEL & ulSASSEMBLY M 286 D . RWP .EXP-TRCK, PERS. DEPT EXPOS. RWP

  • DATE...NUMBE.k......

.....E.R NUMB A ........C.TIVITY............. ..NTRG....D.E .... E.M......S. E CO R HOUR, TASK DESCBI >e

          • PJ{ y

>re cre.** 850104 010603 D91K010 CORE FLOOD LINE 3 CN 0.142 3.03 [ fElW'D(QCN/fRAN$PDR$/A ALI$l$,rtrere. g -g ( $ 850117 010697 091K010 CORE FLOOD LINI 1 HP 0.115 1.57 L DECON/,TSANSPORT/ ANALYSIS

  • 850117 010697 091K010 CORE FLOOD LINE 1 CN 0.120 1.57 L

DiCON/TBANSPOR /ANAEXSIS,ygg g.g 850205 010819 D91K010 CORE FLOOD LINE 1 HP 0.110 2 58 hffgyg {[hgf/$ffyfP LYj R 850205 010819 D91K010 CORE FLOOD LINE 1 CN O 118 2.55 , g ng p3gp7h, RAGE'LEADtCREWSECTIONS 850222 010953 D91K010 CORE FLOOD LINE 2 CN 0.035 1.23 ggg7;ggg_gpg CTMT 'I'd f ogggfgggg9 3 SUBTOTAL - EXP-TRCK NUMBER. DC1K010 gspg I [E E G= 9 GAMMA SCAN & PAL KAGE LEADSCREW SECTIONS HOURS. 0 640000 GAMMA SCAN & PAC 4 AGE LEADSCREW SECTIONS RWP 12.530000 LOAD LDSCR PACKALE INTO SHIPPING CASK LOAD LDSCR PACKALE INTO EMIPPING CASK . GRAND, TOTAL - LOAD LDSCR PACKAG.I INTO SHIPPING CASK PERS ENTRG. 4809 LOAD LDSCR PACKAGE INTO SHIPPING CASK EXPOS REM. 507 38000 LEADSCREW CUTTING AREA CLEANUD RWP HOURS 10493.740 LEADSCREW CUTTING AREA CLEANUP END REPORT LEADSCREW CUTTING AREA CLEANUP LEADSCREW CUTTING AREA CLEANUP RECEIVE / GAMMA SCAN / PACKAGE LEADSCREWS RECEIVE / GAMMA SCAN / PACKAGE LEADSCREWS RECEIVE / GAMMA SCAN / PACKAGE LEADSCREWS RECEIVE / GAMMA SCAN / PACKAGE LEADSCREWS LOAD LEADSCREW DRUMS INTO SHIPPING CASK LOAD LEADSCREW DRUMS INTO SHIPPING CASK e LOAD LEADSCREW DRUMS INTO SHIPPING CASK '4 LOAD LEADSCREW URUMS INTO SHIPPING CASK jf LOAD LEAD $ CREW DRUMS INTO SHIPPING CASK LEADSCREW CUTTING AREA CLEANUP LEADSCREW CUTTING AREA CLEANUP LEADSCREW CUTTING AREA CLEANUP R8 BASEF:ENT SLUDGE SAMPLES RB BASEMENT SLUDGE SAMPLES RB BASEMENT SLUDGE SAMPLES AS-BUILT RVHSS SHIELDING SURVEY NEUTRON SOURCE SECURE SPREADER RING / SECURE PENDANT -!!F SECURE SPREADER RING / SECURE PENDANT -IIF INSPECT IIF PENDANT SUPPORTS TRANSPORT PLENUM SAMPLES TRANSPORT PLENUM SAMPLES TRANSPORT PLENUM SAMPLES TRANSPORT PLENUM SAMPLES UNDERHEAD RAD CHARACTERIZATION UN'ERHEAD RAD CHARACTERIZATION UNDERHEAD RAD CHARACTERIZATION

DATE 022186 PAGE 20 ............. T. A SK D E.S.C.R I P T I O N se.. ..se.nesessesesses, PAR COMMUNICATIONS MODS /INSTL POWER CTRS PAR COMMUNICATIONS MODS /INSTL POWER CTRS MODIFY PLENUV JACK FLUSH HOSE FOR INSTALLING PLENUM TOOLING FLUSH HOSE FOR INSTALLING PLENUM TOOLING INSPECT AS BUILT PLENUM STORAGE STAND INSTALL / STAGE PAR EQUIPMENT REMOVE U-I TURNBUCKLE AND LINK PLATES STAGE TOOLS & EQUIPMENT FOR PLENUM INSP. WALKDOWN PAR VIDEO EQUIPMENT SLING INSPECTION TOOL STORAGE WALKDOWN REPAIR PAR TOOLS AND EQUIPMP T REPAIR PAR TOC.S AND EQUIPMENT STAGE PLENUM INSPECTION TOOLS PREP PAR VIDEO EQUIPMENT PREP PAR VIDED EQUIPMENT INSTALL STIFF LEG ON IIF PLATFORM COVER IIF PLATFORM VIA TURNBUCKLES INSTALL PORTABLE PLATFORM - IIF COVER INSTALL PORTABLE WORK PLATFORM ERECT SCAFFOLD - MAIN FH BRIDGE ERECT SCAFFOLD FOR MAIN FH BRIDCZ MAKE HANDRAILS REMOVABLE INSPECT PLENUM JACK SEATING SURFACES INSPECT PLENUM JACK SEATING SURFACES INSPECT PLENUM JACK SEATING SURFACES INSPECT PLENUM SEATING SURFACES-IIF COV INSPECT PLENUM SEATING SURFACES-IIF COV INSPECT PLENUM JACK SEATING SURFACES INSPECT SEATING SURFACE IN PLENUM REMOVE / RELOCATE REFUEL CANAL SCAFFOLD MOVE PLATFORM TO S0. END OF REFUEL CANAL MOVE AUX FH BRIDGE PLATFORM PLENUM INSPECTION-TOP OF IIF COVER PLENUM INSPECTION-TOP OF IIF COVER

,,ac.a... . - - ~ BIBUOGR AF% D AT A SHEET ,, ~ w, .m -,uv ,-.~,, - Evaluation of iclear Fan *hitj DornW < ;ioning Proj 2-t s N ~ SS gg $ l-c,~ ~ lur,;ary,g.a tus Peport go um m q - 77 . m 8:

.!qd mit negg er g rr
I g

j, 3-4 n zw n r 1 9~ ' g.1 M i i _ic -. mg p a A _.'.1___ g g._ _ _ _.ajgg _ _._Q t e nga._. _. _. -- 1.g_' ' S: S$rt bt5500 TY !s5h r: 5 "SS 5""~~ mrd "'TS Irt: 1"'" m 0 i %vge. ::: L sii ! 1errc% SERT V 22:599 YM,g " E55"S3 1me r* a. % ~ 8 ',; w m __S_ Sed 3: S c,5 a z ~"" nx] -v WO3~ __._.o c a:s., a gjg.. .gg.__ __ zzmaneem _. w__ -,-omazz gg g gggg a pyryg-- ~~ s. UNC %@fa r Untgggggggg55zzgggggga g3;gaggg mga 3 ;uper W:notioniy(("j((QEEEEgggg[yy EQigggg ggp nhry - -- - -- Fe 1/ ~ ' *- tu rJ', ;rrr%gt,c,'--'rrrrrrr gm5f5555 rey d$grLm c. n ~a

a
EE9"ME5*9999??E9"EE "5.i#rrti 55S Sf=3r$5
o. n y. x. J,.J 4~~~ ~~C: " "~~~~sSS aan"Sa wa

~'S . :litiSi39$ssasikp-520705555 ----Pi----35L{-B. n. + arrrerr--- -rrrr< aa --aaaa m .-.- u o on dF

$$$"$$99005'"$5

?? S$9999 Vth bbg??dd t.ngmeewgneettisihgy$g $ Di,'>*et Ima ~~a==~~~~ wo--"" U,ce of Nucle 5r Regulatory Research Technical U. S. Nuclear Regulatory Commission '""*'"c = o"~ ~ " Washington, DC 20555 April 23, 1979 to Aoril 16. 1985 ta 5. ** u f vE N T 4 8'

  • NC'E5 ta ab57aac? 20C' o,e e, wasa This document summarizes information concerning Three Mile Island Unit 2 reactor defueling and disassembly activities being performed concurrently with decontamination of the facility during the period of April 23, 1979 to April 16, 1985.

Data collected from activity reports, reactor containment entry records, and other sources were placed in a computerized information retrieval / manipulation system which permits extraction / manipulation of specific data which could be utilized in planning for recovery activities should a similar accident occur in a nuclear generating plant. The information is presented in both computer output form and a manually assembled summarization This report contains only the man-hours spent and radiation exposure actually incurred during performance of tasks in radiation areas and does not include support activities outside of radiation areas. This report covers the period of activities from April 23, through April 16 1985. a t, Agaas a%D DCCuve %f 4%at v56

  • % Ctscaertons decontamination radiation exposure data acquisition IF avat at'to v STa f f vt NY 6

'7 SE Cuai T v C t a55'a ica f.ON 's NwwSta Of *auts "uiic'TSssified unlimited 9 5. a a v c t *55,..C a r.o. x e. a.cu un'Il,a s si f i ed s

DATE 022186 PAGE 28 ....................SC.RIPTION TASK DE = POLAR CRANE BRAKE INSPECTION POLAR CRANE TASK FORCE INSPECTION POLAR CRANE TASK FORCE INSPECTION POLAR CRANE TASK FORCE INSPECTION INSPECT AND PHOTOGRAPH POLAR CRANE INSPECT AND PHOTOGRAPH POLAR CRANE INSPECT AND PHOTOGRAPH POLAR CRANE INSPECT OPERABILITY OF P.C. COMPONENTS INSPECT OPERABILITY OF P.C. COMPONENTS VIBRATION CHECK OF POLAR CRANE VIBRATION CHECK OF POLAR CRANE NRC POLAR CRANE INSPECTION NRC POLAR CRANE INSPECTION POLAR CRANE WALKDOWN AND INSPECTION POLAR CPANE WALKDOWN AND INSPECTION POLAR CRANE WALKDOWN AND INSPECTION POLAR CRANE WALKDOWN POLAR CRANE WALKDOWN INSPECT AUX HOIST DRUM BEARING SUPPORT FUNCTIONAL TEST OF P.C. COMPONENTS NRC INSPECTION OF POLAR CRANE WALKDOWN AUX HOOK UPPER SHEAR NEST INSTALL POLAR CRANE MARKERS INSTALL POLAR CRANE MARKERS REPLACE FILLER PLATES FOR RAIL CLAMPS REPLACE FILLER PLATES FOR RAIL CLAMPS REPLACE FILLER PLATES FOR RAIL CLAMPS REPLACE BOLTS IN UPPER SPREADER PLATE GEAR BOX OIL SAMPLES MOVE RIus'NG-RACK TO 347' LEVEL RESET SNAP RING ON FLEX COUPLING RESET SNAP RING ON FLEX COUPLING RESET SNAP RING ON FLEX COUPLING POLAR CRANE SNAP RING - 427 & 440 AUXILIARY HOIST MECHANICAL INSPECTION AUXILIARY HOIST MECHANICAL INSPECTION ADJUST DRUM BRAKES ON POLAR CRANE ADJUST P C. BRAKES / INSTALL COTTER PINS CONTINUITY AND MEGGER TEST ON HOIST CONTINUITY AND MEGGER TEST ON P.C. CONTINUITY AND MEGGE' TEST ON P C. REPLACE FRAYED CABLE ON GOLO HOIST-P.C. REPLACE FRAYED CABLE ON GOLO HOIST-P.C. CONTINUITY AND MEGGER TEST OF P.C. REPLACE AUX HOIST BRAKES CHANGE OIL AND GREASE AUX HOIST

DATE 022186 PAGE 29 PNO 28 .TMI-2 UNC: DDS - ACTIVITY REPOR T - REACTCR DEFUEL & DISASSEMBLY M 286 0 . RWP .EXP-TRCK, PERS. DEPT EXPOS. RWP,

  • DATE... NUMBER.............B.ER...

.......CTIVI.T.Y NUM C REM HOU TA A 850208 010839 D45J002 P.C. MECHANICAL ..E.N T R G.... OD E........RS.........................S.K DESCRIPTION 4 CN 0.362 10 28 INSTALL SCAFFOLD FOR AUX HOIST INSPECT. 850220 010941 D45J002 P.C. MECHANICAL 8 CN 0.928 18.48 LUBE HOIST BRAKES AND TROLLEY

  • 850220 010941 D45J002 P.C. MECHANICAL 1 QA 0.071 2.52 LUBE HOIST BRAKES AND TROLLEY 850226 010987 D45J002 P.C.

MECHANICAL 22 CN 1.763 51.63 INSPECT SHEAVES / LUBE AUX HOOK WIRE ROPE

  • 850226 010987 D45J002 P.C.

MECHANICAL 1 MD 0.100 2.92 INSPECT SHEAVES / LUBE AUX h .K WIRE R0PE 850321 011180 D45J002 P.C. MECHANICAL 1 QA 0.056 1.30 FINAL INSPECTIUN-AUX HOIST BRAKES

  • 850321 011180 D45J002 P.C. MECHANICAL 2 CN 0.245 3.75 FINAL INSPECTION-AUX HOIST BRAKES 850321 011185 045J002 P.C. MECHANICAL 4 CN 0.422 10.53 CLEAN AREA /NDE AUX HOOK
  • 850321 011185 D45J002 P.C.

MECHANICAL 1 MD 0.126 2.77 CLEAN AREA /NDE AUX HOOK 850322 011194 045J002 P.C. MECHANICAL 9 CN 1.012 24.10 MODIFY UPPER LIMIT SWITCH / REMOVE SHEAVE 850328 011246 045J002 P.C. HECHANICAL 6 CN 0.522 17.43 REMOVE 5 TON HOIST / REPAIR LIMIT SWITCH . SUBTOTAL - EXP-TRCK NUMBER = D45J002 PERS ENTRG. 139 EXPOS REM. 14 234000 RWP HOURS. 313.63000 .840210 008429 D45J003 P C. ELECTRICAL 2 EL 0.267 3.42 REPLACE MR DELAY / DEFEAT LIMIT SWITCHES 840213 008452 045J003 P.C. ELECTRICAL 1 EL 0.085 1.07 REPLACE ~ COIL ON MAIN CONDUCTOR

  • 840213 008452 D45J003 P.C. ELECTRICAL 1 CN 0.070 1.12 REPLACE COIL ON MAIN CONDUCTOR 840215 008467 D45J003 P.C. ELECTRICAL 2 EL 0.087 1.82 RESTORE TROLLEY LIMYT SWITCH 840307 008585 045J003 P.C. ELECTRICAL 2 EL 0.328 6.93 TEST LDWER LIMIT SWIl04
  • 840307 008585 D45J003 P.C. ELECTRICAL 1 UM 0.197 2.83 TEST LOWER LIMIT SWITCH
  • 840307 008585 D45J003 P.C. ELECTRICAL 1 CN 0.120 3.43 TEST LOWER LIMIT SWITCH 840515 009010 D45J003 P.C. ELECTRICAL 9 CN 1.537 24.70 REMOVE BRIDGE CONDUCTOR BAR 840521 009038 045J003 P.C. ELECTRICAL 3 CN 0.252 4.40 REMOVE BRIDGE CONDUCTOR BAR e 840604 009132 D45J003 P.C. ELECTRICAL 2 CN 0.198 3.32 REPAIR 5 TON HOIST

%4 840606 009143 045J003 P.C. ELECTRICAL 2 CN 0.185 3.78 REPAIR S TON HOIST -d 840608 009158 D45J003 P.C. ELECTRICAL 5 CN 0.508 8.60 FEEDER REPLACEMENT 8 840611 009167 D45J003 P.C. ELECTRICAL 7 CN 0.667 9.52 POWER FEEDER REPLACEMENT 840613 009194 D45J003 P.C. ELECTRICAL 1 AD 0.090 1.58 PPOVIDE EMERGENCY ACCESS TO POLAR CRANE

  • 840613 009194 D45J003 P.C. ELECTRICAL 1 AM 0.107 1.53 PROVIDE EMERGENCY ACCESS TO POLAR CRANE 840613 009195 D45J003 P.C. ELECTRICAL 2 EL 0.211 3.92 TROUBLFSHOOT AND REPAIR POLAR CRANE 840613 009199 045J003 P.C. ELECTRICAL 2 CN 0.251 3.87 REPAIR 5 TON HOIST PENDANT 840615 009208 045J003 P.C. ELECTRICAL 3 CN 0.290 5.83 REPLACE TROLLEY BUMPER BLOCKS 840618 009215 045J003 P.C. ELECTRICAL 2 CN 0.092 2 47 REPLACE TROLLEY STOPS 840618 009216 D45J003 P.C. ELECTRICAL 2 EL 0.115 2.77 DEFEAT TROLLEY LIMIT SWITCH 840622 009270 D45J003 P.C. ELECTRICAL 2 EL 0.158 3.22 RESTORE AND TEST TROLLEY LIMIT SWITCH 840623 009287 D45J003 P.C. ELECTRICAL 4 EL 0.330 6.52 REPAIR POLAR CRANE 840705 009384 045J003 P.C. ELECTRICAL 2 EL 0,080 2.05 DEFEAT TROLLEY LIMIT SWITCH 840711 009429 D45J003 P.C. ELECTRICAL 2 CN 0.071 1.52 REPAIR S TON HOIST 840723 009521 D45J003 P.C. ELECTRICAL 2 EL 0.093 1.90 DEFEAT POLAR CRANE LIMIT SWITCH 840725 009553 D45J003 P.C. ELECTRICAL 3 EL 0.902 12.62 TROUBLESHOOT AND RE PAIR POLAR CRANE 8840725 009553 045J003 P.C. ELECTRICAL 2 HP 0.172 4.45 TROUBLESHOOT AND *EPAIR POLAR CRANE 840726 009554 D45J003 P.C. ELECTRICAL 4 EL 0.399 7.62 TROUBLESHOOT & REta!R P.C.

PEND. CONTROL

  • 840726 009554 D45J003 P.C. ELECTRICAL 2 CN 0.160 3.78 TROUBLESHOOT & REPAIR P.C.

PEN 0. CONTROL 840727 009563 D45J003 P.C. ELECTRICAL 6 EL 0.576 11.43 TROUBLESHOOT POLAR CRANE 840816 009712 045J003 P.C. ELECTRICAL 1 EL 0.130 2.38 P.C. AUXILEARY HOIST WALKDOWN 8840816 009712 045J003 P.C. ELECTRICAL 1 CN 0.138 2.35 P.C. AUXILEARY HOIST WA*.KDOWN 840822 009752 D45J003 P.C. ELECTRICAL 1 EL 0.120 2.23 P.C. AUXILEARY HOIST WALKDOWN 8840822 009752 D45J003 P.C. ELECTRICAL 1 CN 0.133 2.28 P.C. AUX 1 LEARY HOIST WALKDOWN 841101 010215 D45J003 P.C. ELECTRICAL 2 EL 0.220 4.37 TROUBLESHOOT POLAR CRANE ELECTRICAL SYS

DATE 022186 PAGE 30 PNO 29 .TMI-2 UNC-DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 0 . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. .......E.RNUMB........... T..I V I T Y........ ..E.N T RG. ....E.M..............................................ION........... AC CODE R HOURS TASK DESCRIPT

  • D. A T E.. NUMB. E.R.

850103 010595 045J003 P.C. ELECTRICAL 4 CN 0.470 8.55 AUX HOIST ELECTRICAL DEVICE REPLACEMENT 850208 010848 D45J003 P.C. ELECTRICAL 8 CN 0.918 17.38 AUX HOIST ELECTRICAL DEVICE REPLACEMENT 850214 010888 D45J003 P.C. ELECTRICAL 12 CN 1.555 29.22 AUX HOIST FUNCTIONAL TESTING 850219 010912 D45J003 P.C. ELECTRICAL 8 CN 0.940 18.82 AUX HOIST FUNCTIONAL TESTING

  • 850219 010912 D45J003 P.C. ELECTRICAL 1 MM 0.087 2.20 AUX HOIST FUNCTIONAL TESTING 850225 010965 D45J003 P.C. ELECTRICAL 6 CN 0.707 14.35 AUX HOIST FUNCTIONAL TESTING 850322 011195 D45JC03 P.C. ELECTRICAL 3 CN 0.336 9.12 REPLACE AUX HOIST ZERO SPEED SWITCH 850325 011198 D45J003 P.C. ELECTRICAL 3 CN 0.245 6.25 REPLACE AUX HOIST ZERO SPEED SWITCH 850327 011239 D45J003 P C ELECTRICAL 3 CN 0.177 4.20 AUX HOIST SLOW SPEED MOTOR CHECK

. SUBTOTAL - EXP-TRCK NUMBER. D45J003 PERS ENTRG. 134 EXPOS REM 14.774000 RWP HOURS. 275.72000 .840109 008226 045J004 P.C. LOAD TEST 4 CN 0.654 1C.28 MARK MISSILE SHIELDS AND LOAD FRAME 840206 008395 045J004 P.C. LOAD TEST 1 EL 0.127 1.70 COMPLETE NO-LOAD TEST

  • 840206 008395 D45J004 P.S.

'040 TEST 2 CN 0.147 3.78 COMPLET( NO-LOAD TEST

  • 840206 008395 045J004 P.C.

LOAD TEST 1 QA 0.063 1.33 COMPLETE NO-LOAD TEST 840206 008397 D45J004 P.C. LOAD TEST 4 CN C.208 4.18 REPLACE LUG BOLTS ON P.C. LIFT F RAME 840208 008421 045J004 P.C. LOAD TEST 7 CN 0.811 14.80 STAGE RIGGING FOR LOAD TEST

  • 840208 008421 D45J004 P.C.

LOAD TEST 2 MM 0.229 3.85 STAGE RIGGING FO.< LOAD TEST 840210 008428 D45J004 P.C. LOAD TEST 1 EL 0.090 1.95 REMOVE 5 TON HrAST AND MAN 3ASKET 3840210 008428 D45J004 P C. LOAD TEST 4 CN 0.408 7.55 REMOVE 5 TCN H0!ST AND MAN BASKET 840213 008440 045J004 P.C. LOAD TEST 6 CN 0.810 10.08 POLAR CRANE LOAD ASSEMBLY

  • 840213 008440 D45J004 P.C.

LOAD TEST 4 MM 0.775 9.17 POLAR CRANE LOAD ASSEMBLY 8 *840213 008440 D45J004 P.C. LOAD TEST 1 EL 0.140 1.95 POLAR CRANE LOAD ASSEMBLY '4 *840213 008440 D45J004 P.C. LOAD TEST 2 IC 0.240 2.13 POLAR CRANE LOAD ASSEMBLY DJ 840215 008465 045J004 P.C. LOAD TEST 11 CN 1.859 29.74 POLAR CRANE LOAD TEST ACTIVITIES

  • $40215 008465 D45J004 P.C.

LOAD TEST 2 MM 0.334 5.58 POLAR CRANE LOAD TEST ACTIVITIES

  • 840215 008465 D45J004 P.C.

LOAD TEST 2 QA 0.4!0 6.28 P01AR CRANE LOAD TEST ACTIVITIES 840217 008481 D45J004 P.C. LOAD TEST 5 CN 1.069 16.47 POLAR CRANE LOAD TEST

  • 340217 008481 D45J004 P.C. LOAD TEST 1 EL 0.203 3.23 POLAR CRANE LOAD TEST
  • 840217 008481 D45J004 P.C.

LOAD TEST 1 QA 0.200 3.10 POLAR CRANE LOAD TEST 840228 008541 045J004 P.C. LOAD TEST 5 CN 1.065 17.07 POLAR CRANE LOAD TEST

  • 840228 008541 D45J004 P.C.

LOAD TEST 1 EL 0.250 3.97 POLAR CRANE LOAD TEST

  • 840228 008541 045J004 P.C.

LOAD TEST 2 IC 0.150 2.23 POLAR CRANE LO40 TEST 840229 008545 D4SJ004 P.C. LOAD TEST 11 CN 2.694 37.04 POLAR CRANE LOAD TEST

  • 840229 008545 D45J004 P.C.

LOAD TEST 2 QA 0.430 5.93 POLAR CRANE LOAD TEST

  • 840229 008545 045J004 P.C.

LOAD TEST 2 EL 0.442 7.87 POLAR CRANE LOAD TECT

  • 840229 008545 D45J004 P.C.

LOAD TEST 4 MM 0.903 15.77 POLAR CRANE LOAD TEST 840302 008549 D45J004 P.C. LOAD TEST 4 CN 0.763 10.25 INSTALL PLATFORM Oh SPREADER FRAME 840302 008552 D45J004 P.C. LOAD TE ST 2 CN 0.330 4.42 DISASSEMBLE LOAD TEST ASSEMBLY 840305 008559 D45J004 P.C. LOAD TEST 12 CN 3.061 46.63 DISASSEMBLE LOAD TEST FRAME / CLEAN HOOK

  • 840305 008559 D45J004 P.C.

LOAD TEST 1 MM 0.260 4.42 DISASSEMBLE LOAD TEST FRAME / CLEAN HOOK

  • 840305 008559 D45J004 P.C.

LOAD TEST I EL 0,229 4.02 DISASSEMBLE LOAD TEST FRAME / CLEAN HOOK 840307 008583 D45J004 P C. LOAD TEST 1 EL 0.128 2.38 DISASSEMBLE LOAD TEST FRAME /NDE HOOK

  • 840307 008583 045J004 P.C.

LOAD TEST 4 CN 0.451 6.88 DISASSEMBLE LOAD TEST FRAME /NDE HOOK

  • 840307 008583 045J004 P.C LOAD TEST 2 CA 0,101 1.32 DISASSEMBLE LOAD TEST FRAME /NDE HOOK 840308 008590 D45J004 P.C.

LOAD TEST 4 CN 0.739 9.95 REPLACE MAN BASKET &5 TON HOIST-MAIN HOOK

  • 840308 008590 D45J004 P.C.

LOAD TEST 1 MM 0.165 2.70 REPLACE MAN BASKET &5 TON HOIST-MAIN HOOK 840314 008627 045J004 P.C. LOAD TEST 4 CN 0.688 12.00 INSPECT WIRE PCPE ON P.C. MAIN HOIST

DATE 022186 PAGE 31 PNO 30 .TMI-2 UNC: DDS - ACTIVITY REPORT - REACTOR DEFUEL & DISASSEMBLY M 286 D . RWP .EXP-TRCK. PERS DEPT EXPOS RWP

  • DATE. NUMBER. NUMBER.

ACTIVITY ENTRG.. CODE REM HOURS.. TASK DESCRIPTION

  • essese,sesses.esessese,sesseessessenesseees.easess.seesse.seseos,mesess.sosses,sesses,sesseessessessessessosassessessessenesse.
  • 840314 008627 D45J004 P.C.

LOAD TEST 1 EL 0 130 2,60 INSPECT WIRE ROPE ON P.C MAIN HOIST 840419 008856 045J004 P.C. LOAD TEST 3 CN 0.167 3.23 INSTALL LOAD RATING SIGNS 840614 009200 D45J004 P.C. LOAD TEST 4 CN 0.440 7.70 ASSEMBLE AFH BRIDGE PLATFORM . SUBTOTAL - EXP-TRCK NUMBER e D45J004 PERS ENTRG e 132 EXPOS REM e 22.403000 RWP HOURS = 345.53000 .850328 011242 D45J006 POLAR CRANE P.M. 18 CN 1 731 40.95 AUX HOIST LOAD TEST . SUBTOTAL - EXP-TRCK NUMBER D45J006 e PERS ENTRG e 18 EXPOS REM e 1.7310000 RWP. HOURS = 40.950000 . 841129 010367 D50H002 ERM-DEFUEL PLATFORM 3 CN 0.136 7.25 AS-BUILT WALL BRACKETS-REFUEL CANAL 841205 010410 D50H002 ERM-DEFUEL PLATFORM 3 CN 0.126 7.57 AS-BUILT FUEL PACKS-REFUE L CANAL

  • 841205 010410 D50H002 ERM-DEFUEL PLATFORM 1 QA 0.040 2.37 AS-BUILT FUEL RACKS-REFUEL CANAL

. SUBTOTAL - EXP-TRCK NUMBER D50H002 = PERS ENTRG e 7 EXPOS REM e 0.3020000 RWP HOURS e 17.190000 .841214 010475 D55F001 FTS MODIFICATIONS 4 CN 0.398 8.00 INSTALL NEW ELECTRICAL EQUIP FOR FTS 850103 010594 D55F001 FTS MODIFICATIONS 2 CN 0.204 3.73 INSPECT UPENDERS 850110 010642 D55F001 FTS MODIFICATIONS 8 CN 0.509 18.55 REMOVE AYDL CYLINDERS & UPENDER FRAME 850201 010790 D55F001 FTS MODIFICATIONS 19 CN 1.480 31.10 STAGE / INSTALL NEW UNITS / RIG OUT OLD UNIT 850214 010889 D55F001 FTS MODIFICATIONS 4 CN 0.186 7.18 REMOVE TRANSF ER TUBE FLANGE 8 850219 010911 055F001 FTS MODIFICATIONS 8 CN 0.285 19.23 TRACK ALIGNMENT FOR UPENDERS '4 850221 010944 D55F001 FTS MODIFICATIONS 4 CN 0.096 1.87 RIG HYDRAULIC UNITS TO 305' LEVEL IU 850305 011048 D55F001 FTS MODIFICATIONS 7 CN 0.928 15.07 STAGE UPENDERS & LATCH ASSY'S IN CANAL 850305 011060 D55F001 FTS MODIFICATIONS 6 CN 0.323 13.18 INSTALL UPENDERS/ ALIGN AND DRILL 8503C7 011072 055F001 FTS MODIFICATIONS 7 CN 0.697 15.93 TERMINATE EXISTING CABLES FOR FTS 850311 011085 D55F001 FTS MODIFICATIONS 19 CN 0.947 56.83 INSTALL UPENDERS/ ALIGN AND DRILL 850315 011138 D55F001 FTS MODIFICATIONS 2 CN 0.089 1.97 REMOVE 2 FH BRIDGE RAIL STOPS 850320 011171 D55F001 FTS MODIFICATIONS 3 CN 0.325 7.23 TERMINATE CABLE FOR FTS . SUBTOTAL - EXP-TRCK NUMBER = D55F001 PERS ENTRG e 93 EXPOS RtM = 6.4670000 RWP HOURS e 199.87000 ,841130 010374 055H001 FH BRIDGE & MAST 4 CN 0.134 4.47 MOVE AFH BRIDGE MANUAL DRIVE 850117 010694 D55H001 FH BRIDGE & MAST 6 CN 0.456 12.79 AS BUILT AFH BRIDGE & TROLLEY RAIL 850125 010747 D55H001 FH BRIDGE & MAST 5 CN 0.305 7.15 MAIN FH BRIDGE ELECTRICAL REMOVAL 850225 010961 055H001 FH BRIDGE & MAST 4 CN 0.415 8.42 LUBE AND INSPECT MAIN FH BRIDGE 850226 010989 D55H001 FH BRIDGE & MAST 4 CN 0.419 8.58 STAGE TOOLS FOR MAIN FH BRIDGE REMOVAL 850228 011004 D55H001 FH BRIDGE & MAST 68 CN 3.425 84.47 CUT MAIN FH BRIDGE 850312 011104 D55H001 FH 3 RIDGE & MAST 29 CN 2.612 62.82 DISMANTLE AND CUT UP MAIN FH BRIDGE 850318 011143 D55H001 FM ERIDGE & MAST 28 CN 3.040 63.35 DISMANTLE AND CUT UP MAIN FH BRIDGE 850326 011224 055H001 FH BRIDGE & MAST 10 CN 0.800 23.43 RIG MATERIAL / CLEAN UP CUTTING AREA . SUBTOTAL - EXP-TRCK NUMBER e D55H001 PERS ENTRG e 158 EXPOS REM = 11.606000 RWP HOURS = 275.48000 . 841207 010423 091K001 FUEL LOCATING SURVEY 5 CN 0.716 7.07 PLACE AND RETRIEVE TLD'S/ SURVEYS e

DATE 022186 PAGE 32 PNO. 31 .TMI-2 UNC: DDS - ACTIVITY REPORT ..EACTOR DEFUEL & DISASSEMBLY M 286 0 . RWP .EXP-TRCK. PERS. DEPT

EXPOS, RWP,

........................IPTION NUMBER ACTIV ENTRG. CODE, REM HOURS. TASK DESCR

  • D A T E... NUMB E.R.

............IT.Y

  • 841207 010423 091K001 FUEL LOCATING SURVEY 2 HP 0.317 2.80 PLACE AND RETRIEVE TLD'S/ SURVEYS 850321 011189 D91K001 FUEL LOCATING SURVEY 3 CN 0.569 4,97 GAMMA CAMERA DATA ACQUISITION-PZR HEAD
  • 850321 011189 D91K001 FUEL LOCATING SURVEY 1 H P' O.385 1.77 GAMMA CAMERA DATA ACQUISITION-PZR HEAD
  • S50321 011189 D91K001 FUEL LOCATING SURVEY 1 ES 0.271 1.80 GAMMA CAMERA DATA ACQUISITION-PZR HEAD 850326 011229 091K001 FUEL LOCATING SURVEY 2 HP 0.255 1.83 GAMMA CAMERA DATA ACQUISITION-PZR HEAD

. SUBTOTAL - EXP-TRCK NUMBER. D91K001 PERS ENTRG. 14 EXPOS REM 2.5130000 RWP HOURS = 20.240000 .841024 010164 091K002 UPPER A OTSG EXTRNL 1 RP 0.040 0.60 INSPECT 'A' D RING - 330'&349' LEVELS

  • 841024 010164 091K002 UPPER A OTSG EXTRNL 2 HP 0.368 2.78 INSPECT

'A' D RING - 330*&349' LEVELS

  • 841024 010164 D91K002 UPPE R A OTSG E XTRNL 3 CN 0.655 3.40 INSPECT

'A' D RING - 330'&349' LEVELS 841024 010165 091K002 UPPER A OTSG E XTRNL 1 HP 0.591 1.15 SAFETY INSPECTION OF

  • A' D RING
  • 841024 010165 091K002 UPPER A OTSG EXTRNL 1 AM 0.549 0.93 SAFETY INSPECTION OF

'A' D RING 841207 010424 D91K002 UPPER A OTSG EXTRNL 1 HP 0.156 1.43 REMOVE MIRROR IMSULATION - OTSG 'A'

  • 841207 010424 091K002 UPPER A OTSG EXTRNL 4 CN 0.478 5.55 REMOVE MIRROR INSULATION - OTSG

'A' 841211 010448 D91K002 UPPER A OTSG E XTRNL 5 HP 0.605 14.02 SET UP EQUIPMENT / CHAR ACiERIZE OTSG

  • 841211 010448 091K002 UPPER A OTSG EXTRNL 2 OP 0.105 4.65 SET UP EQu!PMENT/ CHARACTERIZE OTSG
  • 841211 010448 091K002 UPPER A OTSG E XTRNL 4 CN 0.592 12.33 SET UP EQUIPMENT / CHARACTERIZE OTSG 3841211 010448 091K002 UPPER A OTSG EXTRNL 1 IC 0.023 0.73 SE T UP EQUIPMENT / CHAR ACTERIZE OTSG 8 *841211 010448 091K002 UPPER A OTSG EXTRNL 3 ES 0.441 9.78 SET UP EQUIPMENT / CHARACTERIZE OTSG

'd 010557 091K002 UPPER A OTSG EXTRNL 1 HP 0.133 2.08 RECORD DATA FROM DETECTORS 'A' D RING i**841227 841227 010557 091K002 UPPER A OTSG EXTRNL 1 CN C.163 2.22 RECORD DATA FROM DETECTORS 'A' O RING 841228 010566 091K002 UPPER A OTSG EXTRNL 1 OP 0.025 0.57 RETRIEVE TLD'S 'A' OTSG 'B' D RING WLKWY

  • 841228 010566 D91K002 UPPER A OTSG EXTRNL 1 HP 0.036 0.67 RETRIEVE TLD'S

'A' OTSG 'B' D RING WLKWY 850204 010802 091K002 UPPER A OTSG EXTRNL 2 HP 0.145 1.43 PLACE AND RETRIEVE TLD'S 'A' OTSG $850204 010802 091K002 UPPER A OTSG E XTRNL 3 CN 0.178 2.43 PLACE AND RETRIEVE TLD'S 'A' OTSG . SUBTOTAL - EXP-TRCK NUMBER. D91K002 PERS ENTRG. 37 EXPOS REM 5.2830000 RWP HOURS = 66.750000 .850214 010885 091K007 PZR EXTERNAL 2 CN 0.144 1.65 REMOVE MIRROR INSULATION - PRESSURIZER

  • 850214 010885 D91K007 PZR EXTERNAL 1 HP 0.150 0.92 REMOVE MIRROR INSULATION - PRESSURIZER

, SUBTOTAL - EXP-TRCK NUMBER = 091K007 PERS ENTRG = 3 EXPOS REM 0.2940000 RWP HOURS = 2.5700000 . 850307 011071 091K008 PZR SURGE LINE 5 CN 1.060 7.15 SPECTROMETER READINGS-PZR & SURGE LINE $850307 011071 D91K008 PZR SURGE LINE 2 HP 0.307 4.18 SPECTROMETER READINGS-PZR & SURGE LINE 850314 011128 D91K003 PZR SURGE LINE 3 HP 0'927 6.48 DATA ACQUISITION-PIR & SURGE LINE

  • 850314 011128 091K008 PZR SURGE LINE 2 CN 0.784 2.40 DATA ACQUISITION-PZR & SURGE LINE
  • 853314 011128 091K008 PZR SURGE LINE 2 RP 0.968 2.80 DATA ACQUISITION-PZR & SURGE LINE
  • 850314 011128 091K008 PZR SURGE LINE 2 ES 0.543 3.80 DATA ACQUISITION-PZR & SURGE LINE 850319 011168 D91K008 PZR SURGE LINE 1 HP 0.512 1.25 DATA ACQUISITION-PZR & SURGE LINE
  • 850319 011168 091K008 PZR SURGE LINE 2 CN 1,026 2.40 DATA ACQUISITION-PZR & SURGE LINE
  • 850319 011168 D91K008 PZR SURGE LINE 1 ES 0.060 1.40 DATA ACQUISITION-PZR & SURGE LINE

. SUBTOTAL - EXP-TRCK NUMBER. D91K008 PERS ENTRG. 20 EXPOS REM 6.1870000 RWP HOURS. 31.860000

DATE 022186 PAGE 33 PNO. 32 .TMI-2 UNC. DOS - ACTIVITY REPORT - REACTOR DEFUEL & u!SASSEMBLY M 286 0 . RWP .EXP-TRCK. PERS. DEPT EXPOS. RWP. .............. TASK DE.S.C.RIPTION x DATE. NUMBER...NUMBE.R..........C. T I. VI..T Y........ ..E.N T RG. C.O.DE..,..R E.M....H.OU.RS........ A 850104 010603 D91K010 CORE FLOOD LINE 3 CN . 0.142. 3.03 INSTALL SCAFFOLDING - 305' & 347' LE VELS 850117 010697 D91K010 CORE FLOOD LINE 1 HP 0.115 1.57 GENERIC RAD SURVEY

  • 8' CORE FLOOD LINE
  • 850117 010697 D91K010 CORE FLOOD LINE 1 CN 0.120 1.57 GENERIC RAD SURVEY

'B' CORE FLOOD LINE 850205 010819 091K010 CORE FLOOD LINE 1 HP 0.110 2.58 INSPECT / MEASUREMENTS

  • B' CORE FLOOD LINE 850205 010819 D91K0A0 CORE FLOOD LINE 1 CN 0.118 2.55 INSPECT / MEASUREMENTS
  • B* CORE FLOOD LINE 850222 010953 D91K010 CORE FLOOD. D91K010 LINE 2 CN 0.035 1.23 REMOVE SCAFFOLD AT CORE FLOOD TANK

. SUBTOTAL EX ENTRG P-TRCK NUMBER PERS 9 EXPOS REM HOURS. 0.6400000 RWP 12.530000

  • GRAND-TOTAL -

PERS ENTRL 4 4809 EXPOS REM 507 38000 e RWP HOURS 10493.740 p N LT1 4 I

.,c,O.u a u s ~ oui.- -i m.* O., ccow.ss.Os . ti Oe ~ won a - noe.= = e...... BIBLIOGRAPHIC DATA SHEET i e..... 3 T*f6E.40 $v.fsTLE 4 Atclait %T & ACCE $5 SON %vw.im Evaluation o Nuclear Facility Decommissioning Projects Summary Status Report Three Mile Isla Unit 2 I " '" Reactor Defuelin and Disassembly ebruary 1986 ..u v,.O-, s. , yn. ,0., issa o TMay j u.. 1. D. H. Doerge, R. L. iller, K. S. Scotti 1986 p,aOn c t. v.s-Da. v~a ~mo..a 8 8 ERFOnuiNG OmGANilaflON N AME AND SLING ADDRE 5s narwar le Cadet UNC Nuclear Industries Decommissioning Programs epartment io ~ au-na Fed /300-A/F27, 700 Area P. O. Box 490 Richland, WA 99352 FIN B7568 11 SPON50wsNG ORGANS 2ATaON Naut a%D uniteNG ADOng3 renews, le Caen, t ia TYPE 08 REPORT Division of Engineering Technolo Office of Nuclear Regulatory Resea h Technical U. S. Nuclear Regulatory Commission ' ^ ' " " ' ' ' ' " ' " " " * ' " * " ' ' " Llashington, DC 20555 April 23, 1979 to Aoril 16. 1985 ,3 ss t ve~r... ~Oris ,..sr.cr,m u This document summarizes information concernin T ee Mile Island Unit 2 reactor defueling and disassembly activities being perf d concurrently with decontamination of the facility during the period of April 23, 19 to April 16, 1985. Data collected from activity reports, reactor co ai ent entry records, and other sources were placed in a computerized informatio ret val / manipulation system which permits extraction / manipulation of specific data hich uld be utilized in planning for recovery activities should a similar accide occur a nuclear generating plant. The information is presented in both computer o put form d a manually assembled summarization This report contains only the man-hours spent a radiation e osure actually incurred during performance of tasks in radiation areas d does not in ude support activities outside of radiation areas. This report covers he period of a ivities from April 23, through April 16 1985.

15. st E v WOaso$ ANO DOCUMENT amatv585 t$o OEscRerTOms decontamination radiation exposure data acquisition

...v.6,.,og,si.noi~, i,..,co,., r. c c.s s...c.,,0. ,,~o....O,,.G., , unc'Tassified unlimited is acu a c6 ssi. car.O~ io .c. "E'nMassified s

UNITED STATES specici rouniu ctass nave NUCLEAR REGULATORY COMMISSION PoS'ay3t;[ES Paid WASHINGTON, D.C. 20555 wjsp o g,, OFFICIAL BUSINESS PENALTY FOR PRIVATE USE. $300}}