ML20206F230

From kanterella
Jump to navigation Jump to search
Evaluation of Nuclear Facility Decommissioning Projects. Summary Status Report,Three Mile Island Unit 2,Reactor Building Decontamination
ML20206F230
Person / Time
Site: Crane Constellation icon.png
Issue date: 05/31/1986
From: Doerge D, Miller R, Scotti K
UNC NUCLEAR INDUSTRIES
To:
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
CON-FIN-B-7568 NUREG-CR-4315, NUREG-CR-4315-V02, NUREG-CR-4315-V2, NUDOCS 8606240366
Download: ML20206F230 (163)


Text

-

,/

/*

NUREG/CR-4315 Vol. 2 Evaluation of Nuclear Facility Decommissioning Projects Summary Status Report Three Mile Island Unit 2 l

Reactor Building Decontamination i

Prepared by D. H. Doerge, R. L. Miller, K. S. Scotti i

UNC Nuclear Industries j

Prepared for U.S. Nuclear Regulatory Commission

)

8606240366 860531 DR ADOCK 05000320 PDR t

\\

w~

t b

NOTICE This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government not any agency thereof, or any of their employees, makes any warranty, expressed or implied, or assumes any legal liabihty of re-sponsibility for any third party's use, or the results of such use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such third party would not infringe privately owned rights.

NOTICE Availability of Reference Materials Cited m NRC Pubhcations Most documents cited in NRC publications will be available from one of the following sources:

1.

The NRC Public Document Room,1717 H Street, N.W.

Washington, DC 20555 2.

The Superintendent of Documents, U.S. Government Printing Of fice Post Ollwe Box 37082, Washington, DC 20013-7082 3.

The National Technical Information Service, Springfield, VA 22161 Although the hsting that follows represents the majority of documents cited in NRC publications.

it is not intended to be exhaustive.

Referenced documents available for inspection and conying for a fee from the NRC Pubhc Docu ment Room include NRC correspondence and internal NRC memoranda; NRC Office of Inspection and Enforcement bulletins, circulars, information notices, inspection and investigation notices; Licensee Event Reports; vendor reports and correspondence; Commission papers; and apphcant and hcensee documents and correspondence.

The following documents in the NUREG series are available for purchase from the GPO Sales Program: formal NRC staff and contractor reports, NRC sponsored conference proceedings, and NRC booklets and brochures. Also available are Regulatory Guides, NRC regulations in the Code of Federal Regulations, and Nuclear Regulatory Commission issuances.

Documents available from the National Technical information Service include NUREG series rep 3rts and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission.

Documents available from public and special technical libraries include all open hterature items, such as books, fournal and periodical articles, and transactions. Federal Register notices, federal and state legislation. and congressional reports can usually be obtained from these hbraries i

Documents such as theses, dissertations, foreign reports and translations, and non NRC conference proceedings are available for purchase from the organization sponsoring the publication cited.

Single copies of NRC draf t reports are available free, to the extent of supply, upon written request to the Division of Technical information and Document Control, U S. Nuclear Regulatory Com mission, Washington, DC 20555.

Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC Library, 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from the American National Standards institute,1430 Broadway, New York, NY 10018.

l l

NUREG/CR-4315 Vol. 2 Evaluation of Nuclear Facility Decommissioning Projects Summary Status Report Three Mile Island Unit 2 Reactor Building Decontamination Manuscript Completed: February 1986 Date Published: May 1986 Prepared by D. H. Doerge, R. L. Miller, K. S. Scotti UNC Nuclear Industries Richland, WA 99352 Pr: pared for Divizion of Engineering Technology Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Wc;hington, D.C. 20566 NRC FIN B7568 i

l

ABSTRACT This document summarizes information relating to decontamination of the Three Mile Island Unit 2 (TMI-2) reactor building.

The report covers activities for the period of June 1, 1979 through March 29, 1985.

The data collected from activity reports, reactor containment entry records, and other sources were entered into a computerized data system which permits extraction / manipulation of specific information which can be used in planning for recovery from an accident similar to that experienced at TMI-2 on March 28, 1979.

This report contains summaries of man-hours, manpower, and radiation exposures incurred during decontamination of the reactor building. Support activities conducted outside of radiation areas are excluded from the scope of this report.

Computerized reports included in this document are:

e A chronological summary listing work performed relating to reactor building decontamination for the period specified.

e Summary reports for each major task during the period.

Each task summary is listed in chronological order for zone entry and subtotaled for the number of personnel entries, exposures, and man-hours.

Manually-assembled table summaries are included for:

e Labor and exposures by department e Labor and exposures by major activity iii

4 TABLE OF CONTENTS PAGE

1.0 INTRODUCTION

1 2.0 ACTIVITY SUMMARIES....................... 4 4

2.1 Summary of Labor and Exposures by Department 4

2.2 Summary of Personnel Entries, Exposures j

and Labor by Work Activity 5

1

3.0 DESCRIPTION

OF COMPUTER REPORTS 6

i 3.1 TMI-2 Acronyms and Abbreviations 6

i 3.2 TMI-2 Notes and Descriptions 6

3.3 Activity Report - Reactor Building Decontamination - Chronological Listing..........

6 3.4 Activity Report - Reactor Building Decontamination - Individual Work Activities 6

1 4.0 COMPUTER REPORTS........................

7 4.1 TMI-2 Acronyms and Abbreviations 7

4.2 TMI-2 Notes and Descriptions 13 1

4.3 Activity Report - Reactor Building i

Decontamination - Chronological Listing.........

16 4.4 Activity Report - Reactor Building Decontamination - Individual Work Activities 84 E

4 l

l t

}

i i

i 4

4

)

i i

j V

r

. -. _. ~

l l

EVALUATION OF NUCLEAR FACILITY DECOMMISSIONING PROJECTS PROGRAM THREE MILE ISLAND UNIT 2 Radioactive Waste and Laundry Shipments

1.0 INTRODUCTION

The Three Mile Island Unit 2 (TMI-2) nuclear power station is located near Middletown, Pennsylvania.

TMI-2 is a pressurized water reactor rated at 959 MWo.

The reactor began commercial operation on December 30, 1978.

On March 28, 1979, TMI-2 experienced a partial loss of coolant water which exposed the upper portion of the reactor.

Resulting temperatures in the core region were in excess of 2500F causing considerable damage to the core and possibly to other reactor components.

Contaminated reactor coolant water was released to the reactor building basement and to the auxiliary and fuel handling buildings (Figures 1 and 2). This release resulted in gross contamination requiring extensive decontamination ano waste handling operations to restore these buildings.

Decontamination and repair activities have required many labor man-hours and man-rems of exposure.

Because of the vast quantity of data generated during decontamination, l

equipment recovery and waste handling activities, the U. S. Nuclear Regulatory Commission (NRC) requested that the data be assembled, analyzed, and entered into a computer data base for historical purposes.

The information also serves as a comprehensive base line for future planning, es+.imates, and actions required should a nuclear facility be confronted l

with problems -imilar to those experienced at TMI-2.

Work within tne scope of this report is being conducted under the Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program.

The ENFDP program was originated in 1981 under the auspices of the NRC Office of Nuclear Regulatory Research and is currently administered through the Division of Engineering Technology.

UNC Nuclear Industries (UNC) is responsible for technical direction of the program and for preparation of documentation and summary comparisons of evaluated projects.

See NUREG/CR-2522, " Evaluation of Nuclear Facility Decommissioning Projects," for a cpmplete description of the Program Plan.

Under the ENFDP program, data is assembled in a form that permits input into a computerized decommissioning data system (DDS).

A proprietary computer software packcge, MAPPER, provides a method for accumulation and manipulation of decommissioning performance information.

MAPPER stands for Maintain, Prepare, and Produce Executive Reports. m samm

THREE MILE ISLAND UNIT 2 REACTCR EUa Dii;G (CO HiJf1MEfm AUX!UARY BU1Dif,'G C00UNG TOWER

'1g s=.

g r.........

i i s...,,..... g ll..

g

. m'. v..a..... a i

i,

- '.. ~.

nm.

I c. --- t 9 i c..a....

TlA31TJ EUliDit:G

.s...i n... o l y,7.,,,,.s.,...

mm..........u.

i.~;_n y@4 _

r c== G ie c c.,,, iq.., -

v........ c

-y

_a.o i.

i.

.j 3

,---__._1.,..,

v...... - r, l i a..,c..,

i w

i i

r" r

---. ."? "

E'=.'<.+..**

.j

. _..r s

i n,

lI-

_ ~_,

.E s.

84,.

.N__-,~'

t 8

...e.a,

!....v.,.

e l..

  • ' a h g ts a a,_,,,,,._'*

t"=. /,,

lj.

( aen..ag.e ij,,e_', -~ ~ ' ~

ZZE _

'~~-- ~-- --~

i g e,,..

9 g,,,

l-t y (8***

taa.er.

e 3 o

I. r.,'==

' ' T E " 'm_.E } "-,

sec.. te E--

~.. - :..t..

-l

. =7.'

7.

,1-

F,.'!'l * -

gog..aeq. 0 :yCcd. wt 9.

o

..' ne

..n.

e~u

_ J;m, q-&lL3 b.e...w...

c l

wwww=j b

I l - wr s-.

-L

\\

t,.

N5~hNhbukh/2

~

_.f

-m t

q

-==-^

g %....,.....,..

R.g:ur disa R..ct.e t....t yes.

it.: 1.g em, s.....

Figure 1. Reactor & Auxiliary Buildings.

E

\\

.c, =, _

3 r-.........~... - ~1

n:nu=:.=:m.=Eq....bpgapg: E"X m

...m t.+ti = ' %

lt:itu*::uin'an :':::L..

e ttt t ett r++t t++t ++t+n+++ tt'

tttt. +

i t

~,,

J f- ~.+.

.a A'

]

rtt+t+tt+++t

[

,i i

c o...*

~~

4

~

g,j

{l l[

f a

. ~......

.t.r..,...a *

-b=

v..

l

A) t__.4) i n -,.. U..-

.. i.a m

.a.c 3 4

-~

,i O

C

/

9...'S h h-.J U... - %.

- D.

.. ! D T

m N/

a 1

(

- t_

7x g

- 1.

r-1 E-1 /-...._]

q

~ hL ~ ~ l _ ,14. P-, f =~- 1 i --fI f-". p(". _. ) '~"_.l. o g

  • =,;;;~

__J g g ..m....J .....G.;...... J n n 3 - - ~. 7.--- n g; w ...... ~. ~,.., L._ i r - -,_.; 3 . /s,, u ---- =- e m .; r i....._ u-ua Figure 2. Auxillary & Fuel-Handling Building. n._.

Because of the volume and variety of information being collected at TMI-2, nine categories of ENFDP reports have been established and are as follows: Volume 1 - Reactor Coolant System and Systems Decontamination Volume 2 - Reactor Building Decontamination Volume 3 - Reactor Defueling and Disassembly Volume 4 - Auxiliary and Fuel Handling Building Decontamination Volume 5 - Common Support Facilities and Systems Operations Volume 6 - Plant Stability and Safety Activities Volume 7 - Liquid Waste Handling Volume 8 - Solid Waste Handling Volume 9 - Radioactive Waste and Laundry Shipments Periodic activity status and summary reports for these nine categories will be published as NUREG/CR-4315 Three Mile Island Unit 2 accuments. This report covers activities relating to reactor building decontamination for the period of June 1, 1979 through March 29, 1985. Data have been collected from activity reports, reactor containment entry records and other sources and entered into the DDS. This report contains summaries of personnel entries, exposures and manpower hours spent in radiation areas for the time period specified. Support activities outside of radiation areas are not covered by this report. Additionally, summaries of labor and exposure by department and by activity have been manually-assembled and cross-checked with the computer output. 2.0 ACTIVITY SUMMARIES 2.1 Summary of Labor and Exposures by Department Personnel Labor Exposure Entries Man-Hours Man-Rem AD - Unit 2 Administration 36 49.77 4.818 AM - Administration - Unit 1 36 39.14 2.567 BS - Unit 2 Building Services 5 9.17 0.395 CH - Chemistry - Unit 1 16 87.60 0.015 CM - Unit 2 Maintenance (Gen) 185 321.09 15.575 CN - Contractor (All Crafts) 15,433 39,667.64 365.198 CR - Corporate 220 400.13 30.570 DM - Unit 2 Decon Maintenance 1 0.25 0.005 EG - Engineering Staff - Unit 1 1 1.00 0.032 EL - Unit 2 Electrical Maintenance 130 214.38 14.827 ES - Unit 2 Engineering Staff 36 50.16 3.724 HP - Unit 2 Health Physics 3,395 15,717.50 79.017 IC - Unit Instrument Control 360 787.47 34.480 MD unit 2 Maintenance Administration 9 19.10 0.182 MM - Unit 2 Mechanical Maintenance 222 370.25 17.733 OP - Unit 2 Site Operations 736 1,732.88 42.190 OS - Site Operations - Unit 1 7 15.22 0.582 QA - Quality Assurance 5 6.49 0.271 RC - Radiation Control - Unit 1 38 170.50 0.476 RP - Unit 2 Recovery Program 399 747.75 31.827 RW - Rad Waste - Unit 1 7 11.29 0.198 SE - Unit 2 Security 22 15.32 0.004 UM - Unit 2 Utilities Maintenance 202 348.85 20.084 UT - Utilities Maintenance - Unit 1 2 4.74 0.000 VI - Visitor 23 34.37 1.416 TOTAL RB DECONTAMINATION 21,526 60,822.06 666.186 l l I I _

i 2.2 Summary of Labor and Exposures by Major Work Activity l Personnel Exposure Labor Entries Man-Rem Man-Hours RB - Support Activity 7,132 77.642 21,985.58 RB - Closed Circuit TV 194 28.466 367.45 RB - Radio System 7 0.904 11.97 RB - Spider 8 0.902 17.77 RB - Support Outside Containment 9,671 16.553 29,707.19 RB - Safety Inspection 95 9.324 147.51 Management Tours 46 3.918 54.93 Decon Polar trane 152 18.648 338.41 RB - Decon - 305' Elevation 133 19.058 204.88 RB - Decon - 282' Elevation 138 13.438 231.05 Decon RB D Rings 47 8.446 91.18 Decon "A" D Ring 36 7.965 58.52 Decon "B" D Ring 11 1.613 21.17 Measure Fuel - Lower RV 15 2.958 43.53 Decon RB Canal 84 4.187 159.34 Decon Exp - SDS Survey 81 11.877 138.74 Decon Exp - Gamma Spec 32 8.813 69.62 Decon Exp - Data Acquisition 58 14.873 97.94 Decon Exp - NRC Inspection 92 0.970 344.86 Decon Exp - CCN Relocation 23 2.484 19.99 Decon Exp - Reenergize 305' 6 0.564 5.20 Decon Exp - Videotape 7 1.897 18.75 Decon Exp - Equipment Protection 14 4.582 26.52 Decon Exp - Services 31 1.417 50.09 Decon Exp - Cleanup 52 12.400 97.65 Decon Exp - Radio Test 6 1.805 12.47 Decon Exp - Hatch & Beam 2 0.402 2.83 Decon Exp - Spider Electrical 7 1.405 13.91 Decon Exp - PC Spider 32 10.147 89.86 Decon Exp - Spider 347 21 6.091 45.79 Decon Exp - LP/HP - 305' 41 8.311 112.01 Decon Exp - LP/Mx - Canal 16 3.496 32.70 Decon Exp - LP/HP - 347' 36 6.262 73.13 Decon Exp - Mech. Scrub 3 0.424 8.42 Decon Exp - Strip Coat 7 2.720 20.22 Decon Exp - HPR214 RMV 11 1.726 20.70 RB Decon - 347' Elevation 214 27.145 649.95 Decon RB Dome 35 4.322 68.45 Decon Service Structure 61 8.804 115.00 Decon Air Coolers 177 21.525 233.82 Dose Reduction - Primary Coolant 2 0.106 2.03 Dose Reduction - 347' Elevation 350 35.218 619.68 Dose Reduction - 305' Elevation 214 31.698 585.63 Dose Reduction - 282' Elevation 4 0.573 6.02 Dose Reduction - RVHSS 41 7.598 89.47 RB Corrective Maintenance 175 16.427 302.50 RB P.M. and Survey 293 23.576 612.45 RB Rad Surveys 496 40.922 751.25 TLD Trees - 282' Elevation 4 1.136 6.37 RB Waste Removal 606 54.031 1,125.33 RB Data Acquisition 502 76.317 902.23 RB Decon Exp - Data 5 0.100 10.00 TOTALS: 21,526 666.186 60,822.06 The greatest number of personnel entries (9,671) and the greatest number of man-hours of labor (29,707.19) were associated with reactor building support outside of the containment. These activities primarily involved setup, maintenance and on going support of the anteroom and air locks established for reactor building entries. The greatest exposure by an individual activity is shown, by computer sort, as 77.642 man-rem for Reactor Building Support Activity. However, the next largest exposure listing is more significant. A total of 76.317 man-rem was expended over 502 personnel entries for data acquisition which included sampling, testing, television and photographic surveys of the reactor building.

3.0 DESCRIPTION

OF COMPUTER REPORTS The computer reports included in this document are: 3.1 TMI-2 Acronyms and Abbreviations l This report is a general report listing acronyms and abbreviations used in TMI-2 reports. All acronyms and abbreviations listed in this report are not necessarily used in this document but may be used in other volumes of NUREG/CR-4315. ]l 3.2 TMI-2 Notes and Descriptions This report describes the data by column found in the computer-generated activity reports. It also includes a listing of department code abbreviations. 3.3 Activity Report - Reactor Building Decontamination (chronological listing) This report summarizes data on personnel entries, radiation exposure, and labor man-hours spent in radiation areas during reactor building decontamination. Each line of this computer report is in chronological sequence and represents a task performed by various department personnel. 3.4 Activity Report - Reactor Building Decontamination (individual work activities) This report summarizes data on personnel entries, radiation exposure, and labor man-hours spent in radiation areas by each major work activity. Each major activity is sorted for compilation and subtotaled..

4.0 COMPUTER REPORTS 4.1 TMI-2 Acronyms and Abbreviations

DATE 062585 PAGE 2 PNO I .TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR TMT-2 REPORTS M H3036 .T.FLD. .. MOD.....................D. E. SC R I P T..I ON

  • AC.RONYM.......

....P.NUM.

  • THIS RECORT IS A WORKING DDCUMENT AND WILL BE UPDATED PERIODICALLY.
  • (SOME #0EREVIATIONS FOUND IN DATA HAVE NOT BEEN IDENTIFIED TO DATE THESE
  • ABBREVIATIONS OR ACRONYMS WILL BE IDENTIFIED AND INCLUDED IN SUBSEQUENT
  • REPORTS)

ACC ACCESS ACOUS ACOUSTIC OR ACOUSTICAL ACQ ACQUISITION ACQUI ACQUISITION ADPTR ADAPTER AFHB AUXILIARY AND FUEL HANDLING BUILDING AH AIR HANDLING AHE AIR HANDLING EQUIPMENT AHVG AIR HANDLING VALVE 'O' s AH-C AIR HANDLING VALVE 'C' 00 ALC AUXILIARY LIQUID CLEANUP (EPICOR 2) e ANN ANNULUS APSR AXIAL POWER SHAPING ROD ARLK AIRLOCK AUX AUXILIARY (BUILDING) BL K BLOCK BTLfS) BOTTLE (S) Bwst BORATED WATER STORAGE TANK B&W BABCDCK & WILCOX CAT CHEMICAL ADDITION TANK CCB CHEMICAL CLEANING BUILDING CCTB CHEMICAL CLEANING TANK 'B' CCTV CLOSED CIRCUIT TELEVISION CDT CONDENSATE DRAIN TANK CFT CORE FLOOD TANK CHEM ADD CHEMICAL ADDITION CHK CHECK CLR(S) COOLER (S) CNTRL CONTROL COL COLUMN CONC CONCE NT R ATED COND CONDENSER OR CONDENSATE CONN CONNECT OR CONNECTOR CONST CONSTRUCT OR CONSTRUCTION CONT CONTAMINATED CONTR CONTRACTOR CORR CORRIDOR COUP COUPLE OR COUPLING COV COVERAGE CRD CONTROL ROD DRIVE CRDM CONTROL ROC DRIVE MECHANISM CTMT CONT AINME NT CU CLEAN UP

DATE 062585 PAGE 3 PN0 2 .TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR TMI-2 REPORTS M H3036

  • A

.T.FLD. A..CRO.NYM...... M. OD.. P. N. UM...................D.E.S.C.RIPTIO.N................................................................................ CWST . CONTAMINATED WASTE STORAGE TANK CWT CONTAMINATED WASTE TANK OEBOR DEBORATED OR DEBORATING DECON DECONTAMINATION DEMIN DEMINERALIZER DH DECAY HEAT DHV DECAY HEAT VAULT DISCON DISCONNECT DP DIFFERENTIAL PRESSURE DSMNTL DISMANTLE DWCS DEFUELING WATER CLEANUP SYSTEM EFF EFFLUENT EL ELECTRICAL OR ELEVATION ELEC ELECTRIC OR ELECTRICAL ELEVTR ELEVATOR ELEVIS) ELEVATION (S) EQUIP E QUIPME NT y) EVAP EVAPORATOR e EXP EXPERIMENT FAC FACILITY FHS FUEL HANDLING BUILDING FILT FILTER FLNGE FLANGE FLT FILTER FSV FIRE SERVICE VALVE FTC FUEL TRANSFER CANAL FTS FUEL TRANSFER SYSTEM FUNCT FUNCTION OR FUNCTIONAL GEN GENERAL GLV8X GLOVE 80X HDR HEADER HEPA HIGH EFFICIENCY PARTICULATE AIR HI LEV HIGH LEVEL l WASTE) HP HEALTH PHYSICS (RADIOLOGICAL ENGINEERING) HPR HEALTH PHYSICS IN-LINE MONITOR HRF-68 HIGH RAD FILTER GLOVE 80X HSEMPG HOUSEKEEPING HVAC HEAT, VENTILATION, AIR CONDITIONING H-2 HYDROGEN ICC INTERMEDIATE CLOSED COOLING WATER SYSTEM IIF INTERNALS INDEXING FIXTURE INF INF L UE NT INJ INJECTION INSP INSPECT OR INSPECTION INST INSTRUMENT OR INS TR UME NT ATION INSTL INSTALL OR INSTALLATION IN TE RMED INTERMEDIATE LAS LABORATORY LD LEAD LL LOW LEVEL (WASTE)

DATE 062585 PAGE 4 PNO 3 TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR TMI-2 REPORTS M H3036 .T.FLD.

  • AC R O.N YM... M.O.D. P. NUM......................D. E. S.C.R I P T..I O. N s....

.LINElS) LN(S) LOCA LOSS OF COOLANT ACCIDENT LP LOW PRESSURE MAG MAGNETIO MAINT MAINTAIN OR MAINTENANCE MATL MATERIAL MS MC MOTOR CONTROL MC CTR MOTOR CONTROL CENTER MDH MINI-DECAY HEAT MDHR MINI DECAY HEAT REMOVAL SYSTEM MEAS MEASURE OR MEASUREMENT MISC MISCELLANEOUS MONITIS) MONITOR lS)ATED VALVE MOV MOTOR OPER MT EMPTY I MU MAKE UP d MUF MAKE UP FILTER C3 MUP MAKE UP PUMP 8 MuV MAKE UP VALVE MW MISCELLANEOUS WASTE MWHT MISCELLANEOUS WASTE HOLDUP TANK MWT HISCELLANEOUS WASTE TANK NEUT NEUTRON NI NUCLEAR INSTRUMENT OR INSTRUMENTATION NLS MANUFACTURER'S NAME FOR HYDROLASER PUMP NM NITROGEN MANIFOLD N0ZZ N0ZZLE NRC U. S NUCLEAR REGULATORY COMMISSION NS NUCLEAR SERVICE NUC NUCLEAR NUC INST NUCLEAR INSTRUMENTATION N-2 NITROGEN OPER OPERATION OPS OPERATIONS OTSG ONCE THROUGH STEAM GENERATOR PACK PACKAGE PC OR P.C. POLAR CRANE PENET PENETRATION PERS PERSONIS) OR PERSONNEL PHOTO PHOTOGRAPH OR PHOTOGRAPHIC PKG PACKAGE PM CR P.M. PREVENTATIVE MAINTENANCE PMP PUMP PORV PRESSURE OPERATED RELIEF VALVE PREP PREPARATION PROT PROTECTION PWST PROCESS WATER STORAGE TANK PZR PRESSURIZER RAD RADIATION, RADI0 ACTIVE, RADIOLOGICAL I EMOE

l l DATE 062585 PAGE 5 PNO 4 .TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR TMI-2 REPORTS M H3036 .T.FLD.

  • AC R O. N. YM.... M. OD. P. NUM......................D.E.S.C.RIPT.IO.N...........................

RAP R8 REACTOR BUILDING R RBA RECLAIMED BORIC ACID PUMP ROOM RBAT RECLAIMED BORIC ACID TANK RC REACTOR COOLANT RCST REACTOR COOLANT BLEED TANK RCDT RE ACTOR COOLANT DRAIN TANK RCF RCS REACTOR COOLANT SYSTEM RECIRC RECIRCULATE OR RECIRCULATION RECOMS RECOMBINER RELOC RELOCAIE RES RESIN RET RETURN RMVE REMOVE RM(S) ROOM ($) RO-2A RADIATION DETECTION INSTRUMENT RV REACTOR VESSEL [j RVMSS RE ACTOR VESSEL HEAD SERVICE STRUCTURE RwP RADIATION WORK PERMIT SAM COMMUNICATICNS SYSTEM SAMP SAMPLE SCAF SCAFFOLD SDS SUBMERGED DEMINERALIZER SYSTEM SECT SECTION SERV SERVICE SF SPENT FUEL SFC SPENT FUEL COOLER SFF SPENT FUEL FILTER SFP SPENT FUEL POOL SFV SHLD(G) SHIELD OR SHIELDIkG SPC STAhDBY PRESSURE CONTROL SPEC SPECIAL OR SPECIFICATION SPEC (T) SPECTRA, S PE C T R UM, OR SPECTRDMETER SSTR STAB STABILIZE OR STABILITY SUPP SUPPORT SURV SURVEY Sws-P PUMP IN SPENT FUEL POOL (REMOVED) Sfs SYSTEM TEMP TEMPORARY TER TERMINATE OR TERMINAL THRU THROUGH TK($) TANKISI TLD THERM 0 LUMINESCENT DOSIMETER TRO TUR8 TURBINE (BUILDING) TV TELEVISION UCI MICR0 CURIE

e e DATE 062585 PAGE 6 PNG 5 .TMI-2 UNC: DOS - ACRONYMS AND ABBREVIATIONS FOR TMI-2 REPORTS M H3036 .T.FLD. s==========......N.UM..... = = = = = = = = = = = = = = = =..C. R I. P T. I. O N..e=====se===============se==============ese============se= DES.

  • ACRONYM. MOD.P v

VALVE (USED IN CONJUNCTION WITH A NUMBER OR LETTER) VAC VACUUM VLV VALVE WDG WASTE DISPOSAL-GASEOUS WDL WASTE DISPOSAL-LIQUID WDS WASTE DISPOSAL-SQLID IFR TRANSFER X POR T TRANSPORT END REPORT ea N 8 l 1 CS

4.0 COMPUTER REPORTS 4.2 TMI-2 Notes and Descriptions (.

DATE 062585 PAGE 2 PNO. 1 .TMI-2 UNC: DDS - ACTIVITY REPORT - TMI-2 NOTES AND DESCRIPTIONS M 286 D

  • RwP

.RWP .E MP TRCK. .PERS . DEPT. EXPOS RwP

  • ....E... N UMBE R. NUMB.E. R.............IVITY.............. E. N T R NG....C. OD E..

.....E.M.......U. R. S.. ......... S. K D. E. S.C. R I P T.I O N..................

  • DAT ACT R

HO TA

  • DATA IN THIS REPORT ARE COMPLETE THROUGH MARCH 31. 1985. SUBSEQUENT DATA
  • WILL BE ANALYZED AND ADDED PERIODICALLY.
  • NOTES:
  • I.

DESCRIPTION OF DATA IN EACH COLUMN; RWP D4TE - THE DATE OF ISSUE OF THE RADIATION WORK PERMIT. THE PERMIT MAY COVER A SINGLE ENTRY 09 MAY COVER ENTRIES OVER A PERIOD OF TIME OF UP TO ONE WEEKS DURATION. RWP NUMBER - RADIATION WORK PERMIT IDENTIFICATION NUMBER. EXP TRCK NUMBER-EXPOSURE TRACKING NUMBER - AN IDENTIFICATION NUMBER e ASSIGNED To A SPECIFIC ACTIVITY. -a Sh ACTIVITY - DESCRIPTIOM OF AN ACTIVITY OR THE LOCATION OF A 8 TASK WITHIN AN ACTIVITY. PERS ENTRG - NUMBER OF PERSONNEL ENTERING A RADIATION AREA OR PERFORMING WORK WHICH IS COVERED BY AN RWP. DEPT CODE - A PERSONNEL ACCOUNTING CODE FOR FUNCTIONAL DE PAR TME NT IDENTIFICATION. (SEE NOTE 2) EXPOS REM - ACTUAL RADIATION EXPOSURE IN REM. RERCORDED ON TLDS WORN SY EMPLOVEES DURING fERFORMANCE OF A TASK WHICH j IS COVERED BY AN RwP. AN EMPLOVEE MAY WORK 04 AN RWP i COVERED TASK FOR SEVER AL HOURS AND RECEIVE' NO ME ASUR-ABLE RADIATION EXPOSURE. RECORD WAS Iw!TIATED IN NOVEMBEd, DRESS-INCLUDING JOB PREPARATION RWP HOURS - TIME SPENT ON A TASK UNDRESS. ETC. 1979. TASK DESCRIPTION - SELF EXPLANATORY

  • 2.

DEPARTMENT CODE ABBREVIATIONS: AD - UNIT-2 ADMINISTRATION AM - ADMINISTRATION - UNIT I BS - UNIT-2 BUILDING SERVICES CH - CHEMISTRY-UNIT I CM - UNIT-2 PLANT OPERATIONS MAINTENANCE - GENERAL CN - CONTRACTOR (ALL CRAFTS) CR - CORPORATE DM - UNIT-2 DECON MAINTENANCE (REPLACED BY RECOVERY PROGRAM-RP) EC - ELECTRICAL MAINTENANCE - UNIT I EG - E NGINEERING STAFF-UNIT I l l 1 ran a

DATE 062585 PAGE 3 PNO. 2 .TMI-2 UNC: DDS - ACTIVITY REPORT - TMI-2 NOTES AND DESCRIPTIONS M 286 D

  • RwP

.RWP .EXP TRCK. .PERS . DEPT. EXPOS RWP. TA

  • D. ATE... NUMB.E R. NUMB.E.R............C. T. IVI T Y.............

....... E. N T R NG. C. ODE.......E.M.....H. OU. R S................... S K D. E SC R IT. T I O. N.......... A R EL - UNIT-2 PLANT OPERATIONS ELECTRICAL MAINTENANCE ES - UNIT-2 ENGINEERING STAFF HP - UNIT-2 HEALTH PHYSICS (RADIOLOGICAL ENGINEERING) IC - UNIT-2 PL ANT OPERATIONS INSTRUMENT AND CONTROL MD - UNIT-2 MAINTENANCE ADMINISTRATION ME - MECHANICAL MAINTENANCE-UNIT I MM - UNIT-2 PLANT OPERATIONS MECHANICAL MAINTENANCE OP - UNIT-2 SITE OPERATIONS OS - OPERATIONS-UNIT I CA - UNIT-2 QUALITY ASSURANCE RC - RADIATION CONTROL-UNIT I RP - UNIT-2 RECOVERY PROGRAM RW - R AD WASTE - UNIT I SE - UNIT 2 SECURITY UM - UNIT-2 UTILITIES MAINTENANCE UT - UTILITIES MAINTENANCE - UNIT I I VI - VISITOR {( END REPORT

4.0 COMPUTER REPORTS 4.3 Activity Report - Reactor Building Decontamination (chronological listing) i _ _ _

DATE 022486 PAGE 2 PNO 1 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

_RWP EXP TRCK. PERS DEPT. EXPOS. TIME TASK DESCRIPTION

  • DATE. NUMBER. NUMBER ACTIVITY ENTR. CODE. REM

. HOURS, 790601 026243 C70H001 RS RAD SURVEYS 1 CR 0.012 0.00 GELI 5PECTRA THROUGH HATCH DOOR

  • 790601 026243 C70H001 RB RAD SURVEYS 3 CN 0.031 0.00 GELI SPECTRA THROUGH HATCH DOOR
  • 790601 026243 C70H001 RB RAD SURVEYS 1 VI 0.025 0.00 GELI SPECTRA THROUGH HATCH DOOR 790605 026589 C70H001 R8 RAD SURVEYS 1 CR O.040 0.00 GELI SPECTRA THROUGH AIRLOCK DOOR
  • 790605 026589 C70H001 RB RAD SURVEYS 5 CN 0.120 0.00 GELI SPECTRA THROUGH AIRLOCK DOOR 790606 026590 C70H001 RB RAD SURVEYS 2 CN 0.009 0.00 GELI SPECTRA THROUGH FENETRATION 605
  • 790606 026590 C70H001 RB RAD SURVEYS 1 VI 0.003 0.00 GELI SPECTRA THROUGH PENETRATION 605 790620 015090 C70H001 RB RAD SURVEYS 1 CR 0.004 0.00 G At ViA RA) SC*

'3A IN PENETRATION 605

  • 790620 015090 C70H001 R8 RAD SURVEYS 2 CN 0.008 0.00 GAMMA RAY SPECTRA IN PENETRATION 605
  • 790620 015090 C70H001 R8 RAD SURVEYS 1 VI 0.004 0.00 GAMMA RAY SPEClRA IN PENETRATION 605 791015 028776 C30G005 DECON EXP-CCTV RELOC 13 CN 0.028 0.00 INSTALL EQU P/ DRILL FLANGE
  • 791015 028776 C30G005 DECON E XP-CCTV RE LOC 1 CR 0 000 0.00 INSTALL Eou!P/ DRILL FLANGE 791108 980293 C20H002 RB - CCTV 5 CN O 007 4 50 (NO TASK DE SCRIPTION GIVE N) 791109 980263 C20H002 RB - CCTW 10 CN O 005 14.33 INSTALL CAMERA & SAMPLE EQUIP-PENET 800321 081772 C20H001 RB SUPPORT ACTIVITY 5 CN 0.075 5.68 SAMPLE GLOVEBOX AIR 800327 081869 C20H001 R8 SUPPORT ACTIVITY 2 CR 0.090 2.75 CONT AI NME NT ENTRY TEAM TRAINING
  • 800327 081869 C20H001 R8 SUPPORT ACTIVITY 2 CN 0.130 3.42 CON T A I NME N T LNTRY TEAM TRAINING
  • 800327 081869 C20H001 RB SUPPOR T ACTIVITY 1 ES 0.065 1.50 CONTAINMENT ENTRY TEAM TRAINING
  • 800327 081869 C20H001 RP SUPPORT ACTIVITY 1 OP 0.090 1.25 CONT AINMENT ENTRY TEAM TRAINING e
  • 800327 081869 C20H001 RB SUPPORT ACTIVITY I VI 0.040 1.25 CONTAINME NT ENTRY TEAM TRAINING d

800331 081960 C20H001 RB SUPPORT ACTIVITY 2 CR 0.165 2.50 SURVEY FOR CONTAINMENT ENTRY TEAM N *800331 081960 C20H001 RB SUPPORT ACTIVITY 1 ES 0.120 1.25 $URVEY FOR CONTAINMENT ENTRY TEAM

  • 800331 0B1960 C20H001 RB SUPPORT ACTIVITY I VI 0.085 1.50 SURVE Y FOR CONTAINMENT ENTRY TE AM
  • 800331 081960 C20H001 RB SUPPORT ACTIVITY 1 CN 0.100 1.25 SURVEY FOR CONT A INME NT E NTRY TEAM 800331 081972 C20H001 RB SUPPORT ACJIVITY

! OP 0.000 0.50 OBTAIN RB SUMP LEVEL READING

  • 803331 0S1972 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 1.00 OBTAIN RB SUMP LEVEL READING 800403 032061 C20H001 RB SUPPORT ACTIVITY 1 CR 0.006 3.62 SAMPLE CONTAINMENT AIR /TE ST MONIT "n IP
  • S00403 082061 C20H001 RB SUPPORT ACTIVITY 4 CN 0.030 12.25 SAMPLE CONTAINMENT AIR / TEST MONIT *C

'd 800408 082139 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 0.83 INSPECT F OR RB EMERGENCY EXIT 800411 0B2236 C20H001 RB SUPPORT ACTIVITY 1 CR 0.000 1.17 SET UP EMERGENCY EXIT APEA

  • 800411 082236 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 5.33 SE T UP EMERGENCY E XIT ARE A 800422 082501 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 1.50 START AIRLOCK PURGE-PREP FOR REENTRY 800424 082557 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 17.08 INSTALL AIRLOCK ALARM BELL 800519 083125 C20H001 RB SUPPORT ACTIVITY I HP 0.000 0.50 PREPARE EMERGENCY Ex!T AREA 2800519 083125 C20H001 RS SUPPORT ACTIVITY 1 CN O.000 1.67 PREPARE E ME RGE NCY EXIT AREA
  • 800519 083125 C2CH001 R8 SUPPORT ACTIVITY 2 CR 0.000 1.00 PRE PARE EME RGE NCY EXIT AREA l

800519 083127 C2C3001 R8 $UPPORT ACIIVITY 3 CN 0.000 6.48 INSERT ANTENNA INTO CONTAINMENT 800520 083124 C20H001 RB SUPPORT ACTIVITY 10 CN 0.032 25.37 RB SURVEILLANCE AND SUPPORT

  • 800520 083124 C20H001 RB SUPPORT ACTIVITY 7 CR 0.019 11.08 RB SURVEILLANCE AND SUPPORT 3800520 083124 C20H001 RB SUPPORT ACTIVITY I ES 0.009 1.50 RB SURVEILLANCE AND SUPPORT
  • 800520 083124 C20H001 R8 SUPPORT ACTIVITY 1 OP 0.000 7.50 R8 SURVEILLANCE AND SUPPORT
  • 800520 083124 C20H001 RB SUPPORT ACTIVITY 2 VI O.010 2.57 RB SURVEILLANCE AND SUPPORT 800520 0B3157 C20H001 RB SUPPORT ACTIVITY 1 CN 0 005 1.00 CHECK OR RE PAIR ANTENNA 800520 083158 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 4.00 TRANSFER REENTRY SAMPLES FOR ANAt alS 800520 083174 C20H001 RB SUPPORT ACTIVITY 4 CR 0.015 1.33 REESTABLISH ARLK OPE RABILITY/LE AK TEST
  • 800520 083174 C20H001 RB SUPPORT ACTIVITY I MM 0.005 0.75 REESTABLISH ARLK OPERABILITY / LEAK TEST 3800520 083174 C20H001 RB SUPPORT ACTIVITY I VI 0.005 1.17 REESTABLISH ARLK OPERABILITY /LEAA TEST
  • S00520 083174 C20H001 RB SUPPORT ACTIVITY 3 CN 0.027 1.00 REESTABLISH ARLK OPERABILITY /LEAT TEST E00522 083216 C20H001 RB SUPPORT ACTIVITY 2 CN 0,003 0.67 SURVEILLANCE OF DERSONNEL AIRLOCN i

DATE 022486 PAGE 3 PNO 2 .TMI-2 UNC. DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RwP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER. NUMBER ACT ENTR. CODE. REM

. HOURS s...... ........,..........IVITY ................. ION TASK DESCRIPT 800523 083243 C20H001 RB SUPPORT ACTIVITY 1 CN 0.001 0.50 AIRLOCK DOOP INSPECTION

  • 300523 083243 C20H001 RB SUPPORT ACTIVITY 1 HP 0.001 0.50 AIRLOCK DOOR INSPECTION
  • 800523 083243 C20H001 RB SUPPORT ACTIVITY 2 CR 0.010 1.00 AIRLOCK DOOR INSPECTION 800523 083245 C20H001 RB SUPPORT ACTIVITY 1 OP 0,015 0.85 INSPECTION / TESTING - DOOR MAINTENANCE 2800523 083245 C20H001 RB SUPPORT ACTIVITY

! EL 0.006 0.85 INSPECTION / TESTING - DOOR MAINTENANCE

  • 300523 083245 C20H001 RB SUPPORT ACTIVITY 3 CN 0.005 1.33 INSPECTION /TE STING - DOOR MAINTEhtNCE 800527 083286 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 1.00 VISUAL INSPECTION - AIRLOCK INNER DOOR 800530 083380 C20f001 RB SUPPORT ACTIVITY 5 CR 0.056 7.17 OPERATIONAL TEST - A!RLOCK INNEP DOOR
  • 800530 083380 C20H001 RB SUPPORT ACTIVITY 4 CN 0.029 11.28 OPERATIONAL TEST AIRLOCK INNER DOOR
  • 800530 083380 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 1.52 OPERATIONAL TEST - AIRLOCK INNER DOOR
  • 800530 083380 C20H001 RB SUPPORT ACTIVITY 2 ES 0.040 4.45 OPERATIONAL TEST - AIhLOCK INNER DOOR
  • 800530 083380 C20H001 RB SUPPORT ACTIVITY 2 EL 0.033 4. 2.1 OPERATIONAL TEST - AIRLOCK INNER DOOR 830604 083480 C20H001 RB SUPPORT ACTIVITY I VI 0.020 2.50 HOOK UP RB SAMPLE PUMP 300623 083843 C20H001 RB SUPPORT ACTIVITY 2 CN 0.015 2.13 PROVIDE POWER RECEPTACLES IN AIRLOCK
  • 800623 083843 C20H001 RB SUPPORT ACTIVITY 3 MM 0.032 1,33 PROVIDE POWER RECEPTACLES IN AIRLOCK
  • 800623 0B3843 C20H001 RB SUPPORT ACTIVITY 2 ES 0.004 2.33 PROVIDE POWER RECEPTACLES IN AIRLOCK

$800623 0B3843 C20H001 RB SUPPORT ACTIVITY 1 EL 0.010 1.33 PROVIDE POWER RECEPTACLES IN AIRLOCK 800624 083868 C20H001 RB SUPPORT ACTIVITY 4 MM 0.111 4,42 PREP FOR DRILLING HOLES IN AIRLOCK DOOR

  • 800624 0B3868 C20H001 RB SUPPORT ACTIVITY 1 EL 0.010 0.58 PREP FOR DRILLING HOLES IN AIRLOCK DOOR
  • 800624 083868 C20H001 RB SUPPORT ACTIVITY 1 ES 0.002 0.03 PREP FOR DRILLING HOLES IN AIRLOCK 000R I
  • 800624 083868 C20H001 RB SUPPORT ACTIVITY 1 CN 0.015 1.58 PREP FOR DRILLING HOLES IN AIRLOCK DOOR 800630 083960 C20H001 RB SUPPORT ACTIVITY 3 MM 0.133 4.50 PREP & DRILL ARLK WALL / REPAIR INNER LATCH Q
  • 800630 0B3960 C20H001 RB SUPPORT ACTIVITY 1 ES 0.000 1.50 PRE P& DRILL ARLK WALL /RE PAIR INNER LATCH
  • 800630 083960 C20H001 RB SUPPORT ACTIVITY 1 CN 0.005 1.95 PREP & DRILL ARLK WALL / REPAIR INNER LATCH 800701 083983 C20H001 RB SUPPORT nCTIVITY 3 Mi 0.055 4.50 PREP & DRILL ARLK WALL / REPAIR INNER LATCH
  • 800701 083983 C20H001 RB SUPPORT ACTIVITY I ES 0.002 1.83 PREP & DRILL ARLK WALL / REPAIR INNER LATCH

$800701 093983 C20HC01 RB SUPPORT ACTIVITY 2 CN 0.017 6.25 PREP & DRILL ARLK WALL / REPAIR INNER LATCH 800704 089115 C50H001 RB P M. AND SURVEY 40 CN 0.027 78.55 EQUIPMENT SURVEILLANCE-AIRLOCKS

  • 800704 OEs115 C50H001 RB P M.

AND SURVEY 4 VI O.001 9.90 EQUIPMENT SURVE IL L ANCE - AIRLOCKS 800713 089140 C50H001 RB P.M. AND SURVEY 27 CN 0.044 64.20 EQUIPMENT SURVEILLANCE-AIRLOCKS

  • 800713 089140 C50HG01 RB P.M.

AND SURVCY 1 VI 0.000 1.92 EQUIPMENT SURVEILLANCE-AIRLOCKS 800716 084170 C50H001 RB P.M. AND SURVEY 1 CN 0.000 1.25 OPERATE PERSONNEL AIRLOCK DOOR

  • 800716 084170 C50H00; RB ?.M.

AND SURVEY I CR 0.015 0.92 OPERATE PERSONNEL AIRLOCK 000R

  • do0716 084170 C50H00 RB P.H, AND SURVEY 1 ES 0.018 0.88 OPERATE PFRSONNEL AIRLOCK DOOR
  • 800716 084170 C50H001 RB P.M.

AND SURVEY 1 VI 0.005 1.75 OPERATE PERSONNEL AIRLOCK DOOR

  • 800716 084170 C50H001 RB P.M.

AND SURVEY I HP 0.005 1.25 OPERATE PERSONNEL AIRLOCK DOOR 800716 084175 C50H001 RB P.M. AND SURVEY I CR 0.004 1.33 LEAKRATE TEST AIRLOCK DOORS l

  • S00716 084175 C50H001 RB P.M.

AND SURVEY 4 CN 0.000 5.89 LEAKRATE TEST AIRLOCK DOORS l

  • 800716 084175 C50H001 RB P.M.

AND SURVEY I HP 0.000 0.08 LEAFRATE TEST AIRLOCK DOORS I 300721 089167 C50H001 kB P M. AND SURVEY 7 CN 0.012 20.75 EQUIPMENT SURVEILLANCE i 800723 0B4255 C70H001 RB RAD SURVEYS 2 CN 0.010 1.75 SPECIAL SURVEY FOR RECOVERY ODERATIONS $800723 084255 C70H001 RB RAD SURVEYS 2 CR 0.225 1 50 SPECIAL SURVEY FOR RECOVERY OPERATIONS

  • 800723 084255 C70H001 RB RAD SURVEYS 1 ES 0.220 0.75 SPECIAL SURVEY FOR RECOVERY OPERATIONS
  • 800723 084255 C70H001 RB RAD SURVEYS 1 VI 0.060 0 83 SPECIAL SURVEY fn2 RECOVERY OPERATIONS
  • 800723 OB4255 C70H001 RB RAD SURVEYS 1 HP 0.000 1.42 SPECIAL SURVEY FGR RECOVERY OPERATIONS 800723 084256 C5CM001 RB P.M.

AND SURVEY 2 CR 0.000 2.58 STAGE EQUIPMENT

  • 800723 084256 C50H001 RB P.M.

AND SURVEY 1 HP 0.000 0.75 STAGE EQUIPMENT 300728 OB9193 C50H001 RB P.M. AND SURVEY 7 CN 0.004 14.27 EQUIPMENT SURVEILLANCE 800804 089221 C50H001 RB P.M. AND SURVEY 11 CN 0 005 24.25 E QUI PME N T SURVEILLANCE 800806 084484 C50H001 RB P.M. AND SURVEY 4 CN 0.036 2.72 DECON PERSONNEL HATCH

l I DATE 022486 PAGE 4 PNO. 3 .TMI-2 UNC-DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT EXPOS. TIME

  • DATE. NUMBER. NUMBER ACTIV

. CODE. REM . HOURS TASK DESCRIPTION

  • ...................................ITY..................ENTR 4.......................
  • 800806 084489 C50H001 RB P.M.

AND SURVEY 5 CR 0.101 4.92 DECON PERSONNEL HATCH $800806 084489 C50H001 RB P.M. AND SURVEY 1 HP 0.005 1.50 DECON PERSONNEL HATCH 800811 089245 C50H001 RB P M. AND SURVEY 11 CN 0.003 102.67 EQUIPMENT SURVEILLANCE S00813 084576 C20H005 R8 SUPP-0UTSIDE CTMT 7 CR 0.011 13.92 PREPARE ANTEROOM FOR RB ENTRIES

  • 800813 084576 C20H005 R8 SUPP-0UTSIDE CTMT 2 CN 0.000 4.00 PRE PARE ANTER0OM F OR R8 ENTRIES 800815 084611 C70H001 RB RAD SURVEYS 3 CR 0.245 4.58 SPECIAL SURVEY FOR R E COVE R Y OPERATIONS
  • 800515 084611 C70H001 R8 RAD SURVEYS 1 OP 0.150 0 70 SPECIAL SURVEY FOR RECOVERY OPE RATIONS
  • 800815 084611 C70H001 R8 RAD SURVEYS 5 CN 0.203 9.71 SPECIAL SURVEY FOR RECOVERY OPERATIONS
  • 800815 084611 C70H001 RB RAD SURVEYS 2 HP 0.002 8 00 SPECIAL SURVEY FOR RECOVERY OPERATIONS
  • 800815 084611 C70H001 RB RAD SURVEYS 1 ES 0.300 0 78 SPECIAL SURVEY FOR RECOVERY OPERATIONS 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 6 CN 0.019 9.54 DECON PERSONNEL AIRLOCK
  • 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 3 CR 0.048 2.00 DECON PERSONNEL AIRLOCK
  • 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.004 2.33 DECON PERSONNEL AIRLOCK
  • 800815 084620 C20H005 RB SUPP-0UTSIDE CIMT 2 HP 0.000 1.92 DECON PERSONNEL AIRLOCK
  • 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 0.58 DECON PERSONNEL AIRLOCK
  • 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT I ES 0.003 0.50 DECON PERSONNEL AIRLOCK 801015 085320 C90K001 RB DATA ACQUISITION 2 HP 0.765 2.45 RADIOLOGICAL SURVEY OF R8
  • 801015 085320 C90K001 RB DATA ACQUISITION 1 CN 0.600 1.50 RADIOLOGICAL SURVEY OF R8 801016 085319 C45H001 RB CORRECTIVE MAINT 1 IC 0.325 0.95 REMOVE SOURCE RANGE PREAMP 801016 085321 C45H001 RB CORRECTIVE MAINT 1 MM 0.200 0.95 REPAIR'& EXERCISE ARLK DOOR-EQUIP HATCH e

E01016 085325 C20H001 R8 SUPPORT ACTIVITY 4 OP 0.010 2.92 DECON& LEAK RATE TEST ARLK 2 & ANTEROOM S01016 085325 C20H001 RB SUPPORT ACTIVITY 2 CN 0.015 3.08 DECONALEAK RATE TEST ARLK 2 & ANTEROOM f **801016 085325 C20H001 801016 085325 C20H001 R8 SUPPORT ACTIVITY 2 CR 0.050 2.00 DECON5 LEAK RATE TEST ARLK 2 & ANTEROOM RB SUPPORT ACTIVITY I HP 0.000 0.22 DECONALEAK RATE TEST ARLK 2 & ANTEROOM 801016 0B5326 C20H001 R8 SUPPORT ACTIVITY 2 HP 0.020 5.00 DECON AND LEAK RATE TEST AIRLOCK NO. 1

  • 801016 0853?6 C20H001 R8 SUPPORT ACTIVITY 9 OP 0.052 14.73 DECON AND LEAK RATE TEST AIRLOCK NO. I 801017 085327 C20H001 R8 SUPPORT ACTIVITY 2 HP 0.015 4.08 DECON AS REQUIRED AFTER ENTRY 3801017 085327 C20H001 RB SUPPORT ACTIVITY 4 CN 0.045 9.08 DECON AS REQUIRED AFTER ENTRY 801017 085347 C50H001 RB P.M.

AND SURVEY I CN 0.020 0.00 LUBE SEAL SURFACE OF INNER AIRLOCK DOOR

  • 801017 085347 C50H001 RB P.M, AND SURVEY I MM 0.030 0.67 LUBE SEAL SURFACE OF INNER AIRLOCK DOOR 801114 085580 C45h001 RB CORRECTIVE MAINT 2 MM 0.120 3.67 REPAIR, CLEAN, LUBE & TEST INNER DOOR SEALS
  • 801114 085580 C45H001 R8 CORRECTIVE MAINT 1 HP 0.040 1.83 REPAIR, CLEAN. LUBE & TEST INNER DOOR SEALS 801114 085589 C45H001 RB CORRECTIVE MAINT 1 OP 0.000 1.17 REPAIR AND TEST INNER 000R SEALS
  • 801114 085589 C45H001 RB CORRECTIVE MAINT 2 CN 0.000 2.50 REPAIR AND TEST INNER 000R SEALS
  • S01114 085589 C45H001 R8 CORRECTIVE MAINT 2 HP 0.078 2.33 REPAIR AND TEST INNER DOOR SEALS
  • 801114 085589 C45H001 RB CORRECTIVE MAINT I UM 0.005 1.17 REPAIR AND TE ST INNER 000R SEALS
  • 801114 085589 C45H001 R8 CORRECTIVE MAINT 1 MM 0.060 1.17 REPAIR AND TEST INNER DOOR SEALS 801117 085600 C20H001 RB SUPPORT ACTIVITY 2 CR 0.000 6.17 DECON ANTE ROOM
  • 801117 085600 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 3.00 DECON ANTEROOM 801130 085564 C90K001 R8 DATA ACQUISITION 2 OP 0.724 3.57 OPS-HP-NRC INSPECTION AND SURVEY
  • 801130 085564 C90K001 RB DATA ACQUISITION 1 VI 0.300 2.17 OPS-HP-NRC INSPECTION AND SURVE Y
  • 801130 085564 C90K001 RB DATA ACQUISITION 2 IC 0.740 3.27 OPS-HP-NRC INSPE C TION ' AND SURVE Y
  • 801130 085564 C90K001 R8 DATA ACQUISITION 1 HP 0.419 1.33 OPS-HP-NRC INSPECTION AND SURVEY
  • 801130 085564 C90K001 RB DATA ACQUISITION 3 CN 1.070 6.40 OPS-HP-NRC INSPECTION AND SURVEY 801130 085566 C90K001 R8 DATA ACQUISITION 3 CN 0.707 4.00 DECCN TEST ME ASUREMENTS 801211 085868 C90K001 RB DATA ACQUISITION 4 HP 1.890 6.93 STAGE VIDEO AND TAKE PHOTOGRAPHS
  • 801211 085868 C90K001 RB DATA ACQUISITION 2 OP 0.020 11.82 STAGE VIDEO AND TAKE PHOTOGRAPHS
  • 801211 085868 C90K001 RB DATA ACQUISITION 2 CN 0.505 3.67 STAGE VIDEO AND TAKE PHOTOGRAPHS
  • 801211 085868 C90K001 RB DATA ACQUISITION 1 CR 0.425 1.45 STAGE VIDEO AND TAKE PHOTOGRAPHS
  • S01211 085868 C90K001 R8 DATA ACOUISITION 1 AD 0.270 2.58 STAGE VIDEO AND TAKE PHOTOGRAPHS r-Im - M

DATE 022486 PAGE 5 PNO 4 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUI1 DING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME TASK DESCRIPTION ........ HOURS.

  • DATE. NUMBER.NUM9ER ACTIVITY ENTR. CODE

.PEM 801211 085869 C90F001 RB DATA ACQUISITION 2 HP 0.700 3.80 REACTOR HEAD AND P.C. SURVEYS

  • 801211 085869 C90t.001 RB DATA ACQUISITION 1 CN 0.235 2 27 REACTOR HEAD AND P C SURVEYS 801211 085870 C90F001 RB DATA ACQUISITION 3 CR 0.655 3.50 DECON TESTS / VIDEO OPERATION R10123 000190 C30G010 DECGN EXP-CLEANUP 2 CR 0.025 6.00 MOVE BUSS BARS TO DECON TENT
  • 810123 000190 C30G010 DECON EXP-CLEANUP 1 CN 0.010 2.92 MOVE BUSS BARS TO DECON TENT 810123 000196 C30G010 DECON EXP-CLEANUP 1 CR 0.000 0.33 MOVE BUSS BARS TO ELEC. CONTR. TRAILER 3810123 000196 C30G010 DECON EXP-CLEANUP 1 CN 0.000 0.08 MOVE BUSS BARS TO ELEC. CONTR. TRAILER 810203 000282 C90t001 RB DATA ACQUISITION 9 HP 0.083 25.33 SAMP& TRASH REMOVAL / ANTEROOM PREP /HP COV
  • 810203 000282 C90t001 RB DATA ACQUISITION 11 CN 0.035 31 42 SAMP& TRASH REMOVAL / ANTEROOM PRE 0/HP COV
  • 810203 000282 C90h001 RB DATA ACQUISITION 5 OP 0.000 4.02 SAMP&TRASF REMOVAL / ANTEROOM PRE P/HP COV
  • 810203 000282 C90F001 RB DATA ACQUISITION 8 IC 0.001 7.43 SAMP& TRASH REMOVAL / ANTE R00t4 PR E P/HP COV
  • 810203 000282 C90t.001 RB DATA ACQUISITION 10 UM 0.007 11.47 SAMP&TR ASH REMOVAL / ANTE ROOM PREP /HP COV
  • S10203 000282 C90t001 RB DATA ACQUISITION 6 EL 0.000 5.02 SAMP&TR ASH REMOVAL / ANTEROOM PRE P/HP COV
  • 810203 000282 C90t001 RB DATA ACQUISITION 1 MM 0.000 1.08 SAMP&TR ASH REMOVAL / ANTEROOM PRE P/HP COV
  • 810203 000282 C90h001 RB DATA ACQUISITION 1 AD 0.005 1_75 SAMP&TR ASH REMOVAL /ANTER0OM PRE P/HP COV
  • 810203 000282 C90h001 RB DATA ACQUISITION 1 CR 0.000 0.67 SAMP& TRASH REMOVAL / ANTEROOM PREP /PO COV
  • 810203 000282 C90E001 RB DATA ACQUISITION 1 ES 0.000 1.03 SAMP& TRASH REMOVAL / ANTEROOM PREP /He COV 810203 000287 C45H001 RS CORRECTIVE MAlNT 1 IC 0.652 1.18 SOURCE RANGE MONITOR REPAIR 810203 000288 C20H002 RB - CCTV 4 OP 1.229 6.08 INST ALL ECTV EQUIP, CABLE & WORK STANDS
  • 810203 000288 C20H002 RS - CCTV 2 IC 1.465 4.62 INST ALL CC TV EQUIP, CABLE & WORK STANDS 8

810203 000288 C20H002 RB - CCTV 7*UM 1.645 8.95 INST ALL CCTV EQUIP, CABLE & WORK STANDS .*M10203 000288 C20H002 RB - CCTV 2 EL 0.551 3.80 INSTALL CCTV EQUIP, CABLE & WORK STANDS 7810203 000288 C20H002 RB - CCTV 1 MM 0 263 1.33 INSTALL CCTV EQUIP, CABLE & WORK STANOS 5810203 000288 C20H002 RB - CCTV 3 CN 1.470 4.97 INS T ALL CC.V EQUIP, CABLE & WORK STANDS 3810203 000288 C20H002 RB - CCTV 1 CR 0 600 2.17 INSTALL CCTV EQUIP, CABLE & WORK STANDS

  • 310203 000288 C20H002 RB - CCTV 1 HP 0.555 1.50 INSTALL CCTV EQUIP, CABLE & WORK STANDS E10204 000313 C20H001 RB SUPPORT ACTIVITY 2 CR 0.020 5.58 DECON ANTER0OM
  • 610204 000313 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 4.25 DECON A ATER00M 810205 000325 C90K001 RB DATA ACQUISITION 1 CR 0.225 1.68 DECON TEST - 347' LEVEL
  • 8;0205 000325 C90K001 RB DATA ACQUISITION 2 CN 0.604 3.37 DECON TEST - 347' LEVEL 5;0205 000326 C20H002 RB - CCTV 2 EL 0.810 3.67 CCTV INSTALLATION AND TESTING
  • $10205 000326 C20H002 RB - CCTV 2 UM 0.750 2.50 CCTV INSTALLATION AND TESTING

$810205 000326 C20H002 RB - CCTV 2 IC 1.020 4.70 CCTV INSTALLATION AND TESTING

  • 810205 000326 C20H002 RB - CCTV 1 HP 0.600 2.35 CCTV INSTALLATION AND TESTING 81C209 000361 C30G010 DECON EXP-CLEANUP 2 CR 0.035 2.50 REMOVE HERCULITE/DECON AIRLOCK

$810209 000361 C30G010 DICON EXP-CLEANUP 1 UM 0.000 1.25 REMOVE FERCULITE/DECON AIRLOCK

  • 810209 000361 C30G010 DECON EXP-CLEANUP 1 CN 0.010 1.25 REMOVE HERCULITE/DECON AIRLOCK 810303 000598 C90K001 RB DATA ACQUISITION 1 Mi 0.000 2.00 PAChAGE PAINT CHIP SAMPLES 3810303 000598 C90h001 RB DATA ACCHISITION I tte 0.000 0.50 PACKAGE PAINT CHTP UMPi r s
  • 810333 000598 C90K001 RS DATA ACQUISl!!ON 2 a.N 0.000 2.00 PAFF W D

- s 810317 000692 C50H001 RB P.M AND SURVEY 1 OP 0.152 1 57 t. to ti

  • 810317 000692 C50H001 RB P.M.

AND SURVEY I CN 0.099 1.Ju LuRVEr 6 VALVL b - 305' LEVEL 810317 000693 C90K001 RB DATA ACQUISITION 5 CN 2.734 12.62 SUMP SAMP/ COLUMN TEST /CHK TV/ TUNNEL SURV 810317 000694 C20H001 RB SUPPORT ACTIVITV 2 HP 0.010 6.83 HP COVERAGE & ENTRY 7 SUPPORT $810317 000694 C20H001 RB SUPPORT ACTIVITY 8 CN 0.030 27.64 HP COVERAGE & ENTRY 7 SUPPORT 810317 000695 C20H001 RB SUPPORT ACTIVITY 2 CN 0.020 1.25 TRANSFER RB WATER SAMPLES

  • 810317 000695 C20H001 RB SUPPORT ACTIVITY 2 CR 0.010 1.17 TRANSFER RB WATER SAMPLES 810317 000696 C20H001 RB SUPPORT ACTIVITY I OP 0.000 1.83 000R SEAL TEST - PERSONNEL AIRLOCK 810319 000713 C45H001 RB CORRECTIVE MAINT 1 CN 0.143 0.95 JUMPER LICHTING CONNECTOR
  • 810319 000713 C45H001 RB CCRRECTIVE MAINT 1 EL 0.120 0.95 JUMPER LIGHTING CONNECTOR

DATE 022486 PAGE 6 PNG 5 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACT 07 BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ACT ENTR. CODE. REM . HOURS TASK DESCRIPTION

  • D. ATE.. NUMBER. NUMBER

..........IVITY

s....................

810319 000714 C90K001 RB DATA ACQUISITION 2 CN 0.608 2.32 RES COL TE ST/CRDmMISSILE SHIELD SURVEYS

  • 810319 000714 C90K001 RB DATA ACQUISITION 1 EL 0.155 0.85 RES COL TEST /CRDM& MISSILE SHIELD SURVEYS 3810319 000714 C90K001 RB DATA ACQUISITION 1 OP 0.210 1.47 RES COL TEST /CRDM& MISSILE SHIELD SURVEYS 810319 000716 C50H001 RB P.M.

AND SURVEY 1 OP O 075 0.47 SUR VE Y 13 VALVES - 305' & 347' LEVELS

  • 810319 000716 C50H001 RB P M.

AND SURVEY 1 CN 0.075 0.47 $URVEY 13 VALVES - 305' & 347' LEVELS 810319 000721 C90K001 RB DATA ACQUISITION 3 CN 0.295 2.73 REPAIR CCTV CAMERA / POWER TO RESIN COLUMN 810320 000724 C90K001 RB DATA ACQUISITION 1 OP 0.102 0.32 SHUT DOWN COL TEST / RETRIEVE SAMP CARBOY

  • 810320 000724 C90K001 RB DATA ACQUISITION 1 CN 0.132 0.32 SHUT DOWN COL TEST /REIRIEVE SAMP CAPBOY 810320 000725 C90K001 RB DATA ACQUISITION 3 CN 0.000 4.83 HP COVERAGE FOR ENTRY 7 810408 000852 C20H001 RB SUPPORT ACTIVITY 2 OP 0.005 2.50 ANTEROOM SUPPORT FOR RB ENTRY 8
  • 810408 000852 C20H001 RB SUPPORT ACTIVITY 5 CN 0.018 9.12 ANTE R0OM SUPPOR T F OR RB ENTRY 8 810430 000985 C20H001 RB SUPPORT ACTIVITY 4 CN O 016 14.33 ANTER0OM SUPPORT FOR RB ENTRY 9 810430 000986 C90K001 RB DATA ACQUISITION 2 FN 0.254 2.33 MODIFY PENETRATION R-561
  • 810430 000986 C90K001 RB OATA ACQUISITION 2 OP 0.000 2.67 MODIFY PENETRATION R-561 810514 001055 C90K001 RB DATA ACQUISITION 1 AD 0.600 2.83 LARGE SCALE DECON TEST
  • 810514 001055 C90K001 RB DATA ACQUISITION 2 CR 1.100 5.00 LARGE SCALE DECON TEST
  • 810514 001055 C90K001 RB DATA ACQUISITION 1 CN 0.200 2.67 LARGE SCALE DECON TEST 810514 001056 C90K001 RB DATA ACQUISITION 4 CR 0.815 5.62 LARGE SCALE DECON TEST
  • 310514 001056 C90K001 RB DATA ACQUISITION 2 HP 0.500 3.03 LARGE SCALE DECON TEST e
  • 810514 001056 090K001 RB DATA ACQUISITION 1 CN 0.624 2.58 LARGE SCALE DECON TE ST DJ 810514 001057 C20H001 RB SUPPORT ACTIVITY 1 AD 0.000 1.42 ANTEROOM SUPPORT FOR RB ENTRY 10

' *810514 001057 C20H001 RB SUPPORT ACTIVITY 1 MM 0.011 8.17 ANTEROOM SUPPORT FOR RB ENTRY 10

  • 810514 001057 C20H001 RB SUPPORT ACTIVITY 1 OP 0.009 1.25 ANTEROOM SUPPORT FOR RB ENTRY 10
  • 810514 001057 C20H301 RB SUPPORT ACTIVITY 1 HP 0.010 4.00 ANTEROOM SUPPORT FOR RB ENTRY 10
  • 810514'001057 C20H001 RB SUPPORT ACTIVITY 6 CN 0.025 21.66 ANTEROOM SUPPOR T F OR RB ENTRY 10 810514 001058 C90K001 RB DATA ACQUISITION 2 UM 0.000 1.33 PACKAGE AND MOVE SUMP SA.

'. E S

  • 810514 001058 C90K001 RB DATA ACQUISITION 3 CN 0.010 5.67 PACKAGE AND MOVE SUMP SAMPLES 810514 001059 C90K001 RB DATA ACQUISITION 1 OP 0.315 2.75 CRDM SURVEY
  • 810514 001059 C90K001 RB DATA ACQUISITION 1 CN O.416 2.67 CRDM SURVEY 810514 001060 C90K001 RB DATA ACQUISITION 4 CN O 732 3.34 SUMP SAMPLING
  • 810514 001060 C90K001 RB DATA ACQUISITION 1 CR 0.200 0.83 SUMP SAMPLING
  • 810514 001060 C90K001 RB DATA ACQUISli!ON 2 OP 0.423 3.33 SUMP SAMPLING 810522 001111 C20G003 DECON EXP-DATA ACQUI 5 CN 0.100 10.00 MOCK-UP GAMMA SPECTROMETER 810528 001147 C20H001 RB SUPPORT ACTIVITY 2 HP 0.013 10.00 ANTEROOM SUPPORT FOR RB ENTRY 11
  • 810528 001147 C20H001 RB SUPPORT ACTIVITY 6 CN 0.039 19.50 ANTE R0OM SUPPOR T F OR SB ENTRY 11
  • 810528 001147 C20H001 RB SUPPORT ACTIVITY I CR 0.015 5.25 ANTEROOM SUPPORT FOR RB ENTRY 11 810528 001148 C50H001 RB P.M.

AND SURVEY I CN 0.090 1.00 COMPLETE SWS-P-1 INSTALLATION 8810528 001148 C50H001 RB P.M AND SURVEY 1 ES 0.332 1.58 COMPLETE SWS-P-1 INSTALLATION 8810528 001148 C50H001 RB P.M AND SURVEY 1 HP 0.480 1.58 COMPLETE SWS-P-1 INSTALLATION 8810528 001148 C50H001 RB P.M. AND SURVEY 1 VI 0.373 1.58 COMPLETE SWS-P-1 INSTALLATION

  • 810528 00!!48 C50H001 RB P.M.

AND SURVEY 1 CR 0.135 1.00 COMPLETE SWS-P-1 INSTALLATION 810528 001149 C50H001 RB P.M. AND SURVEY 2 EL 0.209 1.83 JUMPER LIGHT PANEL - 347' LEVEL 810528 001150 C50H001 RB P.M. AND SURVEY 3 IC 0 761 3.33 RE PLACE HPR-213 & GAITRONICS $810528 001150 C50H001 RB P.M. AND SURVEY 1 HP 0.271 1.08 REPLACE HPR-213 & GAITRONICS 810528 001152 C90K001 RB DATA ACQUISITION 2 CN 1.223 8.15 GAMMA SCAN OF ELEV 305 ' 810528 001156 C20H001 RB SUPPORT ACTIVITY 2 OP O.016 2.00 AIRLOCK INTEGRITY SURVEILLANCE

  • 810528 001156 C20H001 RB SUPPORT ACTIVITY 1 CN 0.005 1.00 AIRLOCK INTEGRITY SURVEILLANCE 810625 001347 C45H001 RB CORRECTIVE MAINT 2 IC 0.878 3.67 CCTV REPAIR /GAITRONICS MAINTENANCE 810625 001348 C45H001 RB CORRECTIVE MAINT 2 EL 0.402 1.50 INSTALL PORTABLE LIGHTS IN STAIRWELL 810625 001349 C90K001 RB DATA ACQUISITION 2 CN 0.642 3.33 SMEAR SURVEY Of WALLS

DATE 022486 PAGE 7 PN3 6 TMI-2 UNC-CDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RuP RWP EKP TRCK.

PERS DEPT. EXPOS.TlYE

  • DATE. NUMBER.huMBER ACTIVITY ENTR CCOE. REM

. HOURS TASK DESCRIPTICN

  • sesses.esesse as sassa.mssessssssssssssssse ssssas assess sesses_======

ases== sesses esessessnessessanssamessassessassessamas 810625 001351 C20H001 RB SUPPCRT ACTIVITY I MM 0 005 0 58 SUPPCR' FOR RB ENTRY 12

  • 810625 001351 C20H001 RB StPPORT ACTIVITY 6 CN O 020 10 84 SUPPORi FOR RB ENTRY 12 s810625 001351 C20H001 RB SUPPORT ACTIV!TY 1 AD 0.060 1.42 SUPPORT FOR RB ENTRY 12 w110625 001351 C20H001 RB SUPPCRT ACTIVITY 2 CR 0.005 3.33 SUPPORT FGR RB ENTRY 12 8810625 001351 C20H001 R8 SUPPORT ACTIVITY 1 OP 0 005 1.25 SUPPORT FOR 98 ENTRY 12 810630 001388 C45H001 RB CORRECTIVE MAINT 2 MM 0 018 2 00 PEPAIR UNIVERSAL FITTINGS-ARLK INTEPLOCK 8810630 001388 C45H001 RB CORRECTIVE MAINT 2 CN 0.012 2 00 REPAIR UNIVERSAL FITTINGS-ARLK INT'RLOCK 810630 001391 C20H001 RB SUPPORT ACTIVITY 2 CN 0.005 2.58 DECON FULL BCDY HARNE SS 810701 001393 C20H001 RB SUPPOR T ACT IVITY 2 AD 0.000 3 25 SUPPORT RB ENTRY 2810701 001393 C20H001 RB SUPPORT ACTIVITY 1 OP O 000 1.17 SUPPOR T FB ENTRY
  • S10701 001393 C20H001 RB SUPPORT ACTIVITY 1 HP O 010 5 08

$UPPORT RB ENTRY 3810701 001393 C20H001 RB SUPPORT ACTIVITY 1 CR 0 000 1.00 SUPPORT RB ENTRY

  • 810701 001393 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 6.75 SUPPORT RB ENTRY 810701 001396 C20H001 RB SUPPCRT ACTIVITY 2 MM 0 030 2.50 INSPECT / REPAIR UNIVERSAL CONNECTIONS
  • 810701 001396 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 0 92 INSPECT / REPAIR UNIVERSAL CONNECTIONS 3310701 001396 C20H001 RB SUPPORT ACTIVITY 1 HP O 010 2.50 INSPECT /PE PAIR UNIVERSAL CONNECTIONS 810706 001420 C20H001 RB SUPPORT ACT!v1TY I CN O 010 2.00 CE CON ANT E ROC'4 AND AIRLCCK
  • S10706 001420 C20H001 RB SUPPORT ACTIVITY 4 CR 0 005 9.00 OECON AN!EROGM AND AIPLGCK 810709 001440 C20H001 RB SUPPCR T ACTIVITY I UM 0.000 1 25 WIPE D0wt. BAGGED ECUIPMENT
  • 810709 001440 C20H001 RB SUPPCRT ACTIVITY 2 CN 0 005 2 50 WIPE DOWN BAGGED ECUIPMENT N 810714 001473 C20H002 RB - CCTV 2 CN 0.005 3.00 INSTALL CCTV CAMERA IN ANTEPOOM N 8810714 001473 C20H002 RB - CCTV 1 IC 0 000 2 00 INSTALL CCTV CAMERA IN ANTEROOM 810723 001530 C90K001 RB DATA ACCUISITION 2 CR 0.005 5.30 ANTERCOM SUPPORT
  • 810723 001530 C90K001 RB OATA ACCUISITION 3 OP 0.015 6 30 ANTEROOM SUFPORT x810723 001530 C90K001 RB DATA ACCUISITION 2 HP 0.015 7.33 ANTEROOM SUPPOR T 8810723 001530 C90K001 RB CATA ACQUISITION 3 CN 0.025 7 42 ANTERCOM SUPPCRT 810723 001531 C90x001 RB DATA ACOUISITION 1 OP 0.604 1.70 RV HE AD SUPVE Y/ SAMPLE REMOVAL 3810723 001531 C90K001 RB DATA ACQUISITION 1 CN 0.641 1.70 RV HEAD SURVEY / SAMPLE REMOVAL 810723 001532 C90K001 RB DATA ACQulSITION 1 IC 0.656 2.13 INST REMOVAL / INSTALL AREA RAD MONIT INST
  • 810723 001532 C90K001 RB DATA ACQUISITION 1 HP O 264 1 13 INST REMO.AL/ INSTALL AREA RAD MGNIT INST 8810723 001532 C90M001 RB DATA ACQUISITION 1 CN 0.610 2.13 INST REMosAL/ INSTALL AREA RAD MONIT INST 810723 001533 C20H002 RB - CCTV 2 IC 1.152 2 33 CCTV MAINTENANCE 810723 001534 C90K001 RB DATA ACCUISITION 1 CN 0.464 1.45 SAMPLE REMOVAL /PHOTOCRAPHS 3810723 001534 C90F001 RB DATA ACQUISITION 1 OP 0 400 1 45 SAMPLE REMOVAL / PHOTOGRAPHS 810806 001632 C20H002 RB - CCTV 1 OP 0.005 4 57 REPAIR CCTV CONTROL BOX 8810806 001632 C20H002 RB - CCTV 9 IC 0.012 23 61 PEPAIP CCTV CONTROL BOX 810810 001653 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 4.50 EQUIPMENT FEASIBILITY TEST 810813 001693 C20H002 RB - CCTV 7 IC 0 000 14 58 REPAIR CCTV CONTROL BOX 810814 001700 C20H001 RB SUPPORT ACTIVITY 2 IC 0.000 3.17 WORK ON PB CCTV HOUSING 810818 001744 C20H002 RB - CCTV 8 IC 0.000 12.92 REPAIR CCTV ECUIP/CALIERATE GAGES l

810824 001791 C20H001 RB SUPPORT ACTIVITY 6 CN 0.008 9 00 RB ENTRY RAINING l 810825 001801 C20H002 RB - CCTV 3 IC 0 002 6 00 REPAIR CCTV EQUIP / CALIBRATE GAGES 810827 001811 C20H001 RB SUPPORT ACTIVITY I MM 0 005 2.58 RB ENTRY SUPPORT i 3810827 001811 C20H001 RB SUPPCRT ACTIVITY 4 OP 0.033 7 42 RB ENTRY SUPPORT

  • S10827 001811 C20H001 RB SUPPORT ACTIVITY I CR 0.000 4.50 RB ENTRY SUPPORT l

8810827 001811 C20H001 RB SUPPORT ACTIVITY ! OS 0.005 2 92 PB ENTRY SUPPORT 8810827 001811 C20H001 RB SUPPCRT ACTIVITY 5 CN 0.030 16.01 RB ENTRY SUPPORT 8810827 001811 C20H001 RB SUPPORT ACTIVITY 2 HP 0 010 4 92 RB ENTRY SUPPORT 810827 001812 C20H002 RB - CCTV 2 IC 0.475 3 90 CCTV MAINT/ INSTRUMENT PEMOVAL 810827 001813 C50H001 RB P.M. AND SURVEY 1 EL 0 836 1.42 SURVEY AIR COOLER /AIG SAFETY EQUIP. l m

DATE 022486 PAGE 8 PNO 7 .TMI-2 UNC-DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWD RWP

.EXP TRCK. PERS. DEPT. EXPOS. TIME . CODE . HOURS TASK DESCRIPTION

  • DATE. NUMBER. NUMBER ACTIVITY ENTR

....... REM s....................................................

  • 810827 001813 C50H001.RB P M.

AND SURVEY Z AD 0.818 1.25 SURVEY AIR COOLER / RIG SAFETY EQUIP. 3810827 (01513 C50H001 RB P.M. AND SURVEY 1 CN 0.864 1 33 SURVE Y AIR COOLER / RIG SAFETY EQUIP. 310827 001814 C90K001 RB DATA ACQUISITION 2 CN 0.862 7.50 GAMMA SPEC AND RO-2A MEASUREMENTS 810827 001815 C90K001 RB DATA ACQUISITION 2 HP 0.614 4 45 HP SURVEYS 3810827 001815 C90K001 R8 DATA ACQUISITION 1 CN 0.400 2.75 HP SURVE VS 810827 001816 C90K001 RB DATA ACQUISITION 1 CN 0.310 1.75 OTSG CLEANING LINE WALKDOVN AND PHOTOS 810903 001866 C90K091 RB DATA ACQUISITION 2 CN 0.140 1.33 WATER LEVEL INSPECTION / POSITION CAMERA 810903 001867 C20HG01 RB SUPPORT ACTIVITY 3 OP 0.000 5.25 PB ENTRY SUPPCRT $810903 001867 C20H3ut RB SUPPORT ACTIVITY 2 CN 0.010 4.00 RB ENTRY SUPPORT 8810903 001867 C20H001 R8 SUPPORT ACTIVITY 1 SE o 000 0 33 RB ENTRY SUPPORT 8810903 001867 C20H001 R8 SUPPORT ACTIVITY 1 UM 0.005 2 58 R8 ENTRY SUPPORT 810924 002034 C20H001 RB SUPPORT ACTIVITY 9 CN 0 025 14 58 R8 ENTRY SUPPORT 8810924 002034 C20H001 PB SUPPORT ACTIVITY 4 OP 0.005 3 17 RB ENTRY SUPPORT 8810924 002034 C20H301 RB SUPPORT ACTIVITY I W1 0 000 0 83 RB ENTRY SUPPORT 8810924 002034 C20H001 RB SUPPORT ACTIVITY 2 EL 0 000 1.67 R8 ENTRY SUPPORT

  • 810924 002034 C20H001 R8 SUPPORT ACTIVITY 2 UM 0 002 6.92 P8 ENTRY SUPPORT
  • 810924 002034 C20H001 RB SUPPORT ACTIVITY I HP O 010 3.50 RB ENTRY SUPPORT 8810924 002034 C20H001 R8 SUPPORT ACTIVITY 1 CR 0 C00 0.83 RB ENTRY SUPPORT

$10924 002035 C90n001 R8 DATA ACQUISITION 1 CN 0.140 1.17 OBTAIN PAINT SAMPLE 810924 002036 C90K001 RB DATA ACQUISITION 2 CN 0.550 4.33 DEFUELING TOOL I NVE N T OR Y / PHO T OS

  • 810924 002036 C90K001 RB CATA ACQUISITION 1 MM 0.349 2.17 DEFUELING TOOL INVENTORY / PHOTOS

,na 810924 002037 C90K001 RB DATA ACQUISITION 1 CN 0.227 1.52 DECON CHARACTERIZATION PHOTOS og 810924 002038 C50H001 RB P.M. AND SURVEY 2 EL 1.555 2.43 TRO READINGS - AIR COOLER FAN MOTORS e 810924 002039 C90K001 R8 DATA ACQUISITION 2 CN 0.900 2.75 AIRfOCK LEAK RATE TESTS

  • 810924 002039 C90K001 R8 DATA ACQUISITION 1 CR 0.582 1.17 AIRLOCK LEAK RATE TESTS 811027 002272 C30G010 DECON E XP-CL E ANUP 6 CN 2.224 11.87 TRASH PICKUP / MOVE EQUIPMENT 811027 002273 C30G001 DECON E XP-SDS SURVE Y 1 CN 0.416 1.82 GEN SURVEY /SDS LINE SURVEY 811027 002274 C30G003 DECCN EXP-DATA ACQUI 1 CN 0.056 0 75 PHOTOGRAPH AREAS ON 305' & 347* LEVELS 811027 002275 C30G012 DECON EXP-HATCH & BEAM 2 CN 0.402 2.83 WALkDOWN/DSMNTL TV CART /RMVE CCTV CNTRL 811027 002276 C30G009 DECON EXP-SERVICES 2 MM 0.103 2.00 INSTALL BLANK FLANGE - PENET R-561 811027 002277 C30G003 DECON E XP-DAT A ACQUI 2 CN 0.515 2.67

$NUBBER INSP / PHOTO INSULATION REMOVAL 811027 002278 C20H001 RB SUPPCRT ACTIVITY 6 CN 0.035 15.85 R8 ENTRY SUPPORT / ANTEROOM PREP

  • 811027 002278 C20H001 RB SUPPORT ACTIVITY 2 UM 0.010 10.00 RB ENTRY SUPPOR T /AN T E ROOM PRE P
  • 811027 002278 C20H001 RB SUPPORT ACTIVITY 5 CR 0.040 12.17 PB ENTRY SUPPOR T/ ANTER0OM PRE P 3811027 002278 C20H001 R8 SUPPORT ACTIVITY 1 HP O 010 3.50 RB ENTRY SUPPORT / ANTEROOM PREP

$11028 002271 C30G003 DECON EXP-DATA ACQUI 2 CN 0.224 2.83 VIDEOTAPE AREAS ON 305' & 347' LEVELS 811029 002292 C20H001 RB SUPPCRT ACTIVITY 7 CN 0.045 20.37 R8 ENTRY SUPPOR T/ ANTEROOM PRE P

  • 111029 002292 C20H001 RB SUPPORT ACTIVITY 3 UM 0.008 7.83 RB ENTRY SUPPORi/ANTERDOM PREP
  • 111029 002292 C20H001 RB SUPPOR L ACTIVITY 7 CR 0.025 15.52 RB ENTRY SUPPORT /ANTERDOM PREP 8811029 002292 C20H001 RB SUPPORT ACTIVITY 1 HP 0.008 3.83 RB ENTRY SUPPORT /ANTER0OM PREP 811029 002294 C30G010 OECON EXP-CLEANUP 1 HP 0.323 1.25 SURVEY HPR-212 & STORAGE AREAS 811029 002295 C30G010 DECON EXP-CLEANUP 4 CN O 786 6.00 PICK UP TRASH / MOVE EQUIPMENT 811029 002296 C30G002 DECON EXP-GAMMA SPEC 2 CN 0 640 7.08 GAMMA SPEC READINGS - AIR COOLERS 811029 002304 C20H001 RB SUPPORT ACTIVITY 2 OP O 000 1.33 LEAK CHECK AIRLOCK DOCRS 3811029 002304 C20H001 RS SUPPORT ACTIVITY I CN O 000 1.08 LEAK CHECK AIRLOCK DOGRS 811102 00232 7 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.33 INSTL WOOD FLOOR IN AIRLOCK / MODIFY PAMP
  • 811102 002327 C20H001 RB SUPPORT ACTIVITY 3 CN 0.010 2.67 INSTL WOOD FLOGR IN AIRLOCK / MODIFY RAMP
  • 811102 002327 C20H001 RB SUPPORT ACTIVITY 1 HP 0.008 2.00 INST L WOOD F L OCR IN AIRLOCK / MODIFY RAMP 811105 002349 C30G001 DECON F X P-SDS SURVE Y I HP 0 300 1 83 GEN SURVEY /SDS LINE SURV/ AIR SAMPLE 311105 002350 C30G010 DECON EXP-CLEANUP 6 CR 2.124 9.63 AREA CLEANUP-305' & 347' LEVELS I

a ai

= 1 DATE 022486 PAGE 9 e PN0 8 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS _ DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER....................IVITY......................ENIR.... E.... R E M........

HOURS.......... TASK D.E.S.CRIPTION ACT . COD .RB ENTRY SUPPORT 811105 002351 C30G004 DECON EXP-NRC INSP 13 CN 0.059 39.09

  • 811105 002351 C30G004 DECON E XP-NRC INSP 2 UM 0.030 4.75 RB ENTRY SUPPORT
  • 811105 002351 C30G004 DECON E XP-NRC INSP 1 OP 0.000 1.50 RB ENTRY SUPPORT

$511105 002351 C30G004 CECON EXP-NRC INSP 5 CR 0.035 10.58 RB ENTRY SUPPORT 88J1105 002351 C30G004 DECON EXP-NRC INSP 3 HP 0.000 13.25 RB ENTRY SUPPORT 811113 002422 C30G004 DECON EXP-NRC INSP 2 OP 0.000 2.50 RB ENTRY SUPPORT

  • S11113 002422 C30G004 DECON E XP-NRC INSP 1 MM 0.000 3.17 RB ENTRY SUPPORT
  • B11113 002422 C30G004 DECON EXP-NRC INSP 3 CR 0.020 8.50 R3 ENTRY SUPPORT

$811113 002422 C30G004 DECON EXP-NRC INSP 9 CN 0.043 33.03 RB ENTRY SUPPORT s311113 002422 C3DG004 DECON EXP-NRC INSP 2 AD 0.000 0.33 RB ENTRY SUPPORT

  • 811113 002422 C30G004 DECON EXP-NRC INSP 3 HP 0.002 18.37 RB ENTRY SUPPORT 811113 002423 C30G003 DECON EXP-DATA ACQUI 2 CN 0.233 2.04 REPLACE HP-R-212 & SOLENOID 811113 002424 C30G003 DECON EXP-DATA ACQUI 1 CN 0.233 1.33 PHOTOGRAPH 347' ELEVATION 811113 002425 C30G010 DECON EXP-CLEANUP 2 CN 0.674 2.45 GENERAL CLEANUP / MOVE EQUIPMENT 811113 002426 C30G003 DECON E XP-DATA ACQUI 1 OP 0.340 1.00 COLLECT BIOLOGICAL SAMPLES 811113 002427 C30G001 DECON EXP-SDS SURVEY 1 HP 0.240 1.55 FIXED POINT SURVEY /SDS LINE SURVEV 811117 002443 C20M001 RB SUPPORT ACTIVITY 1 OP 0.000 0.58 RB ENTRY SUPPORT
  • 811117 002443 C20H001 RB SUPPORT ACTIVITY 1 MM 0.005 3.75 RB ENTRY SUPPORT
  • 811117 002443 C20H001 RB SUPP02T ACTIVITY 4 CR 0.010 16.92 RB ENTRL SUPPORT
  • 811117 002443 C20H001 RB SUPPCRT ACTIVITY 12 CN 0.020 45.72 RB ENTRY SUPPORT 8

S11117 002443 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 3.95 RB ENTRY SUPPORT $, *3811117 002443 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 9.33 RB ENTRY SUPPORT 311117 002446 C30G003 DECON EXP-DATA ACQUI 2 CN 0.137 2.17 INSTALL R AMP E XTENSION 811117 002447 C30G003 DECON E XP-DATA ACQUI I CN 0.203 1.17 PHOTOGRAPH 305* & 347' LEVELS 811117 002448 C30G014 DECON E XP-P.C. SPIDR 4 CN 1.206 9.07 WALKDOWN FOR SPIDER LIF T INSTALLATION 3811117 002448 C30G014 DECOM EXP-P.C -SPIDR I AD 0.283 2.45 WAKhDOWN FOR SPIDER LIFT INSTALLATIGN 811120 002475 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.83 R5 ENTRY SUPPORT 3811120 002475 C20H001 RB SUPPORT ACTIv!TY ! MM 0.005 4.30 RB ENTRY SUPPORT 3811120 002475 C20H001 RB SUPPORT ACTIVITY 11 CN 0.047 33.72 RB ENTRY SUPPORT

  • 811120 002475 C20H001 RB SUPPORT ACTIVITY I CR 0.000 4.42 RB ENTRY SUPPORT 3811120 002475 C20H001 RB SUPPORT ACTIVITY

$ HP 0.013 29.83 RB ENTRY SUPPORT 3811120 002475 C20H001 RB SUPPORT ACTIVITY 1 AD 0.000 0.17 RB ENTRY SUPPORT 811120 002477 C30G003 DECOM EXP-DATA ACQUI 3 CN 0.944 5.33 LOAD & TEST HIGH REACH LIFT PLATFORM 811120 002478 C30G003 DECON E XP-DATA ACQUI 1 CR 0.074 0.83 TEST VIDEO TAPING EQUIPMENT 811203 002548 C20H301 RB SUPPORT ACTIVITY 1 OP 0.000 1.17 RB ENTRY SUPPORT 8811203 002548 C20H001 RB SUPPORT ACTIVITY 17 CN 0.075 58.90 RB ENTRY SUPPORT 3811203 002548 C20H301 RB SUPPORT ACTIVITY 3 HP 0.020 16.58 RB ENTRY SUPPORT 811203 002550 C30G001 DECON E XP-SDS SURVEY 1 CN 0.344 1.50 GEN. SURVEY /SDS LINE SURVEY / AIR SAMPLE 811203 002551 C30G008 DECON EXP-ECUIP PROT 1 CN 0.121 1.30 SURVEY / PROTECT / PHOTO HP-R-214 811203 002552 C30G014 DECOM EXP-P.C. SPIDR 4 CN 1.934 10.67 INSTALL GOOSENECKS & LADDER - P.C.

  • 811203 002552 C30G014 DECON EXP-P.C SPIDR 1 VI 0.359 3.75 INST ALL GOOSE WECKS & LADDER - P.C.

811203 002553 C30G011 DECON EXP-RADIO TEST 1 IC 0.300 2.42 NEW RADIO SYSTEM /CCTV REPAIR 3811203 002553 C30G011 DECON E XP-R ADIO TEST 1 CR 0.694 2.42 NEW RADIO SYSTEM /CCTV REPAIR 811209 002582 C30G004 DECON EXP-NRC INSP 20 CN 0.013 91.40 RB ENTRY SUPPORT $811209 002582 C30G004 DECON EXP-NRC INSP 1 OP 0.000 1.33 RB ENTRY SUPPORT 8811209 002582 C30G004 DEC04 EXP-NRC INSP 3 HP 0.000 27.78 RB ENTRY SUPPORT 811209 002584 C30G001 DECOM E XP-SDS SURVEY ! HP 0.181 0.92 FIXED POINT SURVEY / AIR & TRIT!UM SAMPLES 811209 002585 C30G003 DECON E XP-DATA ACQUI 1 CN 0.090 0.05 REPLACE HP-R-212 8811209 002585 C30G003 DECON EXP-DATA ACQUI 1 IC 0.100 0.05 REPLACE HP-R-212 811209 002586 C30G011 DECON EXP-RADIO TEST 1 CN 0.104 0.73 PROTECT PENET R-507 & CCTV JUNCTION BOX

i I I 1 DATE 022486 PAGE 10 PNO 9 .TMI-2 UMC-DDS - ACTIVITY REPORT-REACTOR SUILDING DECONTAMINATION 286 D

  • RWP

.RWP _EXP TRCK. PERS. DEPT. EXPOS. TIME ACT . REM . HOURS TASK DESCRIPT ..........IVITY....................E.NTR..... CODE ............................===. ION

  • DATE.huMBER. NUMB
  • ...==............ER.==..

............=. ............a===........ 8811209 002586 C30Gott DECON EXP-RADIO TEST 1 IC 0.068 0.73 PROTECT PENET R-507 & CCTV JUNCTION BOK. 811209 002587 C30G005 DECON EXP-CCTV RELOC 1 CN 0.250 1.48 CCTV REPAIR 3811209 002587 C30G005 DECON EXP-CCTV RELOC 1 IC 0.260 1.48 CCTV REPA!R 811209 002588 C30G008 DECON EXP-EQUIP PROT 3 CR 1.212 6.27 EQUIP. PROT. - 305', 347' & 'D' RINGS 3811209 002588 C30G003 DECON EXP-EQUIP PROT 3 OP 1.553 6.20 EQUIP. PROT. - 305', 347' & 'D' RINGS 811209 002589 C50H001 RB P.M. AND SURVEY 1 CN 0.256 1.58 TRANSIENT COMBUSTIBLES INVENTORY

  • 811209 002589 C50H001 RB P.M AND SURVEY

! ES 0.306 1.57 TRANSIfNT COMBUSTIBLES INVENTORY 811209 002590 C30G002 DECON E X P-GAMMA SPEC 3 CN 1.036 7.28 CONTAINMENT CHARACTERIZATION & SAMPLING 8811209 002590 C30G002 DECON EXP-GAMMA SPEC 1 CR 0.160 2.70 CONTAINMENT CHAR ACTERIZATION & SAMPLING 811215 002629 C2CH001 RB SUPPORT ACTIVITY 20 CN 0.075 92.27 RB ENTRY SUPPORT 8811215 002629 C20H001 RB SUPPORT ACTIVITY 2 CR 0.005 2.00 RB ENTRY SUPPORT 8811215 002629 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.75 RB ENTRY SUPPORT 8811215 002629 C20H001 RB SUPPORT ACTIVITY I UM 0.000 1.75 RB ENTRY SUPPORT 8811215 002629 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.25 RB ENTRY SUPPORT

  • S11215 002629 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 9.33 RB ENTRY SUPPORT 811215 002630 C30G001 DECON EXP-SDS SURVEY 1 HP 0.173 0.98 REMOVE TLD'S/ PROTECT HPR-214 811215 002631 C30G001 DECON E X P-SDS SURVE Y I HP 0.105 0.52 HP SURVE Y/ AIR SAMPLES 811215 002632 C30G003 DECON E XP-DATA ACQUI 3 CN 0.886 6.08 COLLECT SURFACE DEPOSITION SAMPLES
  • 811215 002632 C30G003 DECON EXP-DATA ACQUI 2 CR 0.580 3.75 COLLECT SURFACE DEPOSITION SAMPLES a *811215 002632 C30G003 DECON EXP-DATA ACQUI 1 HP 0.190 2.42 COLLECT 7URF ACE DE POSITION SAMPLES ru 811215 002633 C30G002 DECON EXP-GAMMA SPEC 2 CN 0.730 5.17 CONTAINMENT CHARACTERIZATION m *811215 002633 C30G002 DECON E XP-GAM 4A SPEC 1 CR 0.597 3.50 CONTAINMENT CHARACTERIZATION 811215 002634 C30G003 DECON E XP-DAT A ASQUI 1 OP 0.195 0.68 CLOSE AIR DUCT DAMPERS TO 282' LEVEL 811215 002635 C30G003 DECON EXP-DATA ACQUI 1 OP 0.437 1.73 HYDROGEN BURN CHAR ACTERIZATION 811216 003049 C30G002 DECON E XP-GAMMA SPEC 4 CN 0.988 5.38 RIG GAMMA SPECTROMETER & TAME READINGS
  • 811216 003049 C30G002 DECON E X P-GAM 4A SPEC 1 CR 0.515 3.92 RIG GAMMA SPECTROMETER & TAKE READINGS 811217 002649 C20H001 RB SUPPORT ACTIVITY 18 CN 0.005 60.10 RB ENTRY SUPPORT
  • 811217 002649 C20H001 RB SUPPORT ACTIVITY

! OP 0.010 1.67 RB ENTRY SUPPORT 8811217 002649 C20HC01 RB SUPPORT ACTIVITY 3 HP 0.010 13.55 RB ENTRY SUPPORT 811217 002659 C30G003 CECON E X P-DAT A ACQUI 5 CR 2.192 9.63 SURFACE DEPOSITION SAMPLING 8811217 002659 C30G003 DECON EXP-DATA ACOUI 1 CN 0.519 2.05 SURFACE DEPOSITION SAMPLING 811217 002660 C30G001 DECON E XP-SDS SURVEY 1 HP 0.250 0.82 HP SURVEY / AIR SAMPLES 820105 002760 C20H001 RB SUPPORT ACTIVITY 21 CN 0.045 96.12 RB ENTRY SUPPORT

  • S20105 002760 C20H001 RB SUPPORT ACT!v!TV 1 UM 0.000 2.92 RB ENTRY SUPPORT i
  • 820105 002760 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 8.08 RB ENTRY SUPPORT 820105 002761 C30G003 DECCN EXP-DATA ACQUI 1 CN 0.160 2.58 HYDROGEN BURN CHAR / TEST RADIOS 820105 002762 C30G014 DECON E XP-P C. SPIDR 11 CN 3.170 28.08 INSTALL SPIDER LIFT SUPPORTS 820105 002763 C30G001 DECON EXP-SDS SURVEY 1 UM 0.427 1.08 HP SURVEY 820105 002764 C50H001 RB P M AhD SURVEY 1 IC 0.365 1.33 SOURCE RANGE MONITOR TESTING 820107 002783 C20H001 RB SUPPORT ACTIVITY 17 CN 0.014 61.32 RB ENTRY SUPPORT

$320107 002783 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.50 RB ENTRY SUPPORT 8820107 002783 C20H001 RB SUPPOdT ACTIVITY I UM 0.000 4.80 RB ENTRY SUPPORT

  • 820107 002783 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 5.27 RB ENTRY SUPPORT 820107 002784 C45H001 RB CORRECTIVE MAINT 1 IC 0.528 2.32 SOURCE RANGE MONITOR TESTING 820107 002785 C30G001 DECON EXP-SDS SURVEY 1 CN 0.350 1.08 HP SURVEY 820107 002786 C30G014 DECON EXP-P.C. SPIDR 4 CN 1.239 14 50 INSTALL SPIDER LIFT SUPPORTS 820114 002823 C50H001 RB P.M AN> SURVEY 1 IC 0.197 0.75 SOURCE RANGE MONITOR TESTING 820114 002824 C30G001 DECON EXP-SDS SURVEY

! CN 0.511 2.33 HP SURVEY - FIXEO POINTS 820114 002825 C30G011 DECON E XP-RADIO TEST 2 CN 0.639 6.17 ELECTRICAL WAlkDOWN - SP! DER LIFT 820114 CG2826 C30G013 DECCM EXP-SPIDR ELEC 1 CN 0.605 2.58 INSTALL ANTEhMA/ TEST RADIO SYSTEM

DATE 052286 PAGE 11 PNO. 10 RID 24 .THI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUTLDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME AC . ENTR. COD

  • .DA T E... huMBE R. NUMB E R...........

........ T..IV I T Y ..........E . REM....... HOURS............ T. ASK D. E. SCR I.P T I ON 320114 002827 C20H001 RB SUPPORT ACTIVITY 16 CN 0.040 74.92 RB ENTRY SUPPORT 8820114 002827 C20H001 RB SUPPORT ACTIVITY ! OP 0.005 0.92 RB ENTRY SUPPORT sS20114 002827 C20H001 RB SUPPOR T ACTIVITY 1 UM 0.000 4.33 RB ENTRY SUPPORT 8820114 002827 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 12.25 RB ENTRY SUPPORT 820120 002864 C20H001 RB SUPPORT ACTIVITY 6 CN 0.018 10.33 DECON PERSONNEL AIRLOCK / REMOVE TRASH 820126 002894 C20H001 RB SUPPORT ACTIVITY 15 CN 0.061 68.67 RB ENTRY SUPPORT 8820125 002894 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 6.88 RB ENTRY SUPPORT 820126 002895 C30G015 DECON EXP-SPIDER-347 4 CN 0.015 5.00 LOAD TEST SPIDER SUPPORTS 820126 002896 C50H001 RB P M. AND SURVE Y I IC 0.300 1.33 SOURCE RAMGE MONITOR TESTING 820126 002897 C3CC001 DECON EXP-SDS SURVEY 1 CN 0.644 1.83 HP SURVEY /SDS LINE/ ROPE OFF STAIRS 820126 002898 C20G003 DECCN EXP-DATA ACQUI 4 CN 2.117 10.67 VIDEOTAPING 820127 002905 C20H001 RB SUPPORT ACTIVITY 2 CN 0.015 3.00 RB ENTRY SUPPORT 820128 002913 C20H001 RB SUPPORT ACTIVITY 8 CN 0.010 20.58 RB ENTRY SUPPORT $820120 002913 C20H001 RB $UPPORT ACTIVITY I OP 0.000 1.17 RB ENTRY SUPPORT 8820123 002913 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 3.00 RB ENTRY SUPPORT 820128 002916 C30G001 DECON EXP-SDS SURVEY ! CN 0.034 0.50 HP SURVEY / AIR SAMPLES /0XYGEN ANAL. 820129 002924 C20H001 RB SUPPORT ACTIVITY 5 CN 0.010 14.00 PREPARE SURFACE DEPOSITION SAMPLES 820202 002948 C30G015 DECON E XP-SPIDE R-34 7 5 CN 2.635 15.75 STAGE SPIDER LIFT IN CONTAINMENT 820202 002949 C30G015 DECON EXP-SPIDER-347 4 CN I.893 10.83 LOAD TEST SPIDER SUPPORTS / STAGE FORKLIFT 820202 002950 C30G001 DECON EXP-SDS SURVEY 1 CN 0.471 1.42 HP SURVEY /SDS LINE/ AIR SAMPLES 820202 002951 C30G004 DECON E XP-NRC INSP 19 CN 0.030 64.31 RB ENTRY SUPPORT e

  • 820202 002951 C30G004 DECON EXP-NRC INSP 3 HP 0.000 21.67 RB ENTRY SUPPORT pa 320204 002959 C20H001 RB SUPPORT ACTIVITY 17 CN 0.019 84.02 RB ENTRY SUPPORT cm *820204 002959 C20H001 RB SUPPORT ACTIVITY 2 OP 0.007 2.50 RB ENTRY SUPPORT e
  • 820204 002959 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.48 RB ENTRY SUPPORT 8820204 002959 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 16.70 RB ENTRY SUPPORY 820204 002961 C45H001 RB CORRECTIVE MAINT 2 CN 0.263 1.57 WALKDOWN FOR FIRE HOSE REPLACEMINT 820204 002962 C30G001 DECON EXP-SDS SURVEY 1 HP 0.303 2.45 HP SURVEY & JOB COVER AGE 320204 002963 C306003 DECON EXP-DATA ACQUI 1 HP 0.346 1.18 IDENTIFY ORUM CONTENTS 820204 002964 C30G004 DECON EXP-NRC INSP 1 CN 0.364 1.32 RAD SURVEY /NRC INSPECTION
  • 820204 002964 C30G004 DECON E X P-NRC INSP 1 HP 0.374 1.38 RAD SURVEY /NRC INSPECTION 320204 002965 C30G013 DECON EXP-SPIDR ELEC 6 CN 0.800 11.33 ELECTRICAL SERVICE FOR SPIDER LIFT 820204 002973 C20H001 RB SUPPORT ACTIVITY 13 CN 0.024 40.70 DECON ANTEROOM

$820204 002973 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 5.73 DECON ANTEROOM 820208 002989 C20H001 RB SUPPORT ACTIVITY 19 CN 0.066 89.08 DECON ANTER0OM 820208 003010 C20H001 RB SUPPORT ACTIVITY 2 CN 0.005 12.33 INSTALL CONTAMINATION CONTROL CORRIDOR 320209 003008 C20H001 RB SUPPORT ACTIVITY 8 CN 0.005 20.17 DECON ANTEROOM

  • 820209 003008 C20H001 RB SUPPORT ACTIVITY 2 IC 0.000 1.33 DECON ANTEROOM 820211 003019 C20H001 RB SUPPORT ACTIVITY 10 CN 0.010 34.47 INSTALL CONTAMINATION CONTROL CORRIDOR 820211 003027 C30G009 DECCN EXP-SERVICES 4 CN 0.014 5.47 LEAK TEST PENET R561/ INSTALL FLANGE 320215 003031 C20H001 RB SUPPORT ACTIVITY 9 CN 0.003 19.67 INSTALL CONTAMINATION CONTROL CORRIDOR 820216 003041 C20H001 RB SUPPORT ACTIVITY 17 CN 0.068 65.74 RB ENTRY SUPPORT 8320216 003041 C20H001 RB SUPPOR T ACTIVITY 2 HP 0.010 15.67 RB ENTRY SUPPORT 8820216 003041 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 5.17 RB E 4TR Y SU*F OR T 820216 003045 C30G006 DECON E XP-REENER 305 3 CN 0.443 3.37 INSTALL 110V SE*v!CE TO 305' LEVEL 820216 003046 C45H001 RB CORRECTIVE MAINT 4 CN 0.921 4.97 REPLACE FIRE HOSES / REMOVE OLD HOSES 320216 003047 C30G001 DECON E XP-SDS SURVf v 1 HP 0.280 1.50 HP SURVEY /SDS LINE/ SAMPLES 820216 003048 C30G003 DECON EXP-DATA ACQUI I CN 0.152 1.07 PRE-DECON PHOTOGkAPHS 820217 003059 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.83 DECON ANTEROOM AND AIRLOCK 8820217 003059 C20H001 RB SUPPORT ACTIVITY 8 CN 0.00T 12.99 DECON ANTER0OM AND AIRLOCK

DATE 022486 PAGE 12 PNO. 11 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RwP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBE R. NUMBE.R...

.........IVITY ..........E.... REM........ HOURS......................... ION ACT ENTR. COD TASK DESCRIPT .RB SUPPORT ACTIVITY 2 OP 0.000 .1.95 RB ENTRY SUPPORT 840217 003069 C20H001 $820217 003069 C20H001 RB SUPPORT ACTIVITY 19 CN 0.015 45.25 RB ENTRY SUPPORT

  • 820217 003069 C20H001 RB SUPPORT ACTIVITY 4 HP 0.000 13.50 RB ENTRY SUPPORT 820217 003070 C30G001 DECGN E X P-SDS SURVEY 1 HP 0.014 1.67 COLLECT PARTICULATE & TRITIUM SAMPLES 820218 003066 C30G009 DECON E XP-SERVICES 1 CR 0.000 1.17 LEAK TEST PENET R561/ INSTALL FLANGE
  • 820218 003066 C30G009 DEC0r EXP-SERVICES 10 CN 0.022 19.75 LEAK TEST PENET RS61/ INSTALL FLANGE 820219 003086 C3CG001 DECOA EXP-SDS SURVEY 2 HP 0.135 1.58 SPECIAL GAS MONITORING TEAM
  • 820219 003086 C30G001 DECON E XP-SDS SURVEY I CN 0.000 0.67 SPECIAL GAS MONITORING TEAM
  • 820219 003086 C30G001 DECON E XP-SDS SURVE Y 1 AD 0.124 1.08 SPECIAL GAS MONITORING TEAM 820219 003089 C30G001 DECON EXP-SDS SURVEY 1 OP 0.092 0.27 SPECIAL ENTRY
  • 820219 003089 C30G001 DECON kXP-SDS SURVEY 2 CN 0.197 0.53 SPECIAL ENTRY 820220 003090 C30G001 DECON E XP-SDS SURVE Y 1 OP 0.003 0.47 SPECIAL ENTRY
  • 820220 003090 C30C001 DECON E AP-SDS SURVE Y 3 CN 0.195 1.29 SPECIAL ENTRY
  • 820220 003090 C30G001 DECON E AP-SDS SURVEY 1 AD 0.100 0.42 SPECIAL ENTRY 820222 003101 C20H001 RB SUPPCRT ACTIVITY 4 CN 0.005 4.75 DECON ANTEPOOM AND AIRLOCK
  • 820222 003101 C20H001 RB SUPPC1T ACTIVITY 1 HP 0.000 1.00 DECON ANTEROOM AND AIRLOCK 820224 003114 C30G009 DECON EXP-SERVICES 2 CN 0.539 3.92 STAGE DECON HOSES / TEST SYSTEM 820224 003115 C20H001 RB SUPPORT ACTIVITY 31 CN 0.035 116.37 RB ENTRY SUPPORT
  • 820224 003115 C20H001 RB SUPPORT ACTIVITY 5 HP 0.E00 26.33 RB ENTRY SUPPORT 820224 003116 C30G002 DECON EXP-GAMMA SPEC 2 CN 0.202 1.67 REMOVE GAMMA SPECTROMETER FROM RB e 820224 003117 C30G001 DECON E XP-SDS SURVEY 1 AD 0.111 0.58 COMBUSTIBLE GAS SAMPLE 4

DO *820224 003117 C30G001 DECON EXP-SDS SURVEY 2 CN 0.185 1.17 COMGUSTIBLE GAS SAMPLE 'd 820224 003118 C30G009 DECON EXP-SERVICES 3 CN 0.281 4.50 INST / TEST DECUN TEST FLANGE-PENET R-561 820224 003119 C30G009 DECON EXP-EERVICES 1 CN 0.235 1.47 SAFETY INSPECTION - RS 820224 003125 C30G001 DECON EXP-SDS SURVEY 1 CN 0.135 1.33 HP SURVEY /SDS LINE SURVEY 820224 003127 C30G014 DECON E XP-P C, SPIDR 4 CN 1.343 11.67 INSTALL SPIDER LIFT SAFETY LINES 820224 003128 C30G015 DECON EXP-SPIDER-347 4 CN 1.441 10.21 LOAD TEST SPIDER SUPPORTS / REPLACE EQUIP 820224 003128 C30G015 DECON EXP-SPIDER-347 2 MM 0.000 1.67 LOAD TEST SPIDER SUPPORTS / REPLACE EQUIP 820224 003131 C30G009 DECON EXP-SERVICES 6 CN 0.003 8.23 LEAK TEST PENET R-561 820225 003126 C45H001 RB CORRECTIVE MAINT 1 OP 0.035 0.92 VENT FIRE SYSTEM HE ADER/LINE UP VALVING

  • 820225 003126 C45H001 RB CORRECTIVE MAINT 1 HP 0.020 0.92 VENT FIRE SYSTEM HEADER /LINE UP VALVING 820225 003132 C30G001 DECON EXP-SDS SURVEY 1 CN 0.386 1.22 HP SURVEY /SDS LINE/ SAMPLES 820225 003136 C30G001 DECON EXP-SDS SURVEY 1 CN 0.291 2.67 HP SURVEY / AIR SAMPLES /JOS SUPPORT 820226 003137 C20H001 RB SUPPORT ACTIVITY 3 HP 0.000 12.92 RB ENTRY SUPPORT
  • 820226 003137 C20H001 RB SUPPORT ACTIVITY I OP 0.000 1.50 RB ENTRY SUPPORT
  • 820226 003137 C20H001 RB SUPPORT ACTIVITY 26 CN 0.028 103.36 RB ENTRY SUPPORT 820226 003138 C30G008 DECCN EXP-EQUIP PROT 3 CN 0.276 2.80 POLAR CRANE EQUIP PROT.

820226 003139 C30G006 DECON (XP-REENER 305 3 CN 0.121 1.83 INSTALL 110V VAC EXTENSION ON 347' LEVEL 820226 003140 C30G008 DECON EXP-EQUIP PROT 3 CR 1.059 6.15 PROTECT / RELOCATE CCTVS

  • 820226 003140 C30G008 DECON EXP-EQUIP PROT 1 HP 0.361 3.80 PROTECT / RELOCATE CCTVS 820301 003160 C20H001 RB SUPPORT ACTIVITY 4 CN 0 023 12.42 DECON ANTEROOM AND AIRLOCK
  • 820301 003160 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 3.17 DECON ANTEROOM AND AIRLOCK 820302 003170 C45H001 RB CORRECTIVE MAINT 2 OP 0.206 2.75 FIRE SERVICE SYSTEM OPERATIONS SURVEY
  • 820302 003170 C45H001 RB CORRECTIVE MAINT 1 CN 0.156 1.58 FIRE SERVICE SYSTEM OPERATIONS SURVEY 820302 003171 C30G001 DECON E XP-SDS SURVE Y 1 CN 0.228 1.33 FIXED POINT SURVEYS /SDS LINE/ SAMPLES 820302 003172 C20H001 RB SUPPORT ACTIVITY 23 CN 0.080 82.89 RB ENTRY SUPPORT

$820302 003172 C20H001 RB SUPPORT ACTIVITY 6 HP 0.005 39.83 RB ENTRY SUPPORT 820302 003177 C45H001 RB CORRECTIVE MAINT 1 CN 0.005 1.58 OPEN FIRE SYSTEM ISOLATION VALVE

  • 820302 003177 C45H001 RB CORRECTIVE MAINT 1 OP 0.050 1.42 OPEN FIRE SYSTEM ISOLATION VALVE
  • 820302 003177 C45H001 RB CORRECTIVE MAINT 1 HP 0.035 1.42 OPEN FIRE SYSTEM ISOLATION VALVE

DATE 022486 PAGE 13 PNO 12 .THI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. ATE....BER, NUMBER.......................ITY ENTR

.NUM ACTIV ....E . COD . REM . HOURS ......... DESCRIPTION TASK g. 820303 003184 C30G001 DECON E X P-SDS SURVEY 2 HP 0.157 4.65 HP SURVEYS & JOB COVERAGE 2820303 003184 C30G001 DECON E XP-SDS SURVE Y 2 CN O.122 2.75 HP SURVE YS & JOB COVERAGE S20303 003185 C30G005 DECON EXP-CCTV RELOC 1 CN 0.399 2.18 CCTV REPAIR

  • 820303 003185 C30G005 DECON E XP-CCTV RE LOC 1 CR 0.390 2.27 CCTV REPAIR 820303 003189 C30G016 DECON EXP-LP/HP-305*

5 CN 0.000 22.00 OPERATE DECON WATER NLB PUMP

  • 820303 003189 C30G016 DECON E XP-LP/HP-305
  • 1 CR 0.000 0.92 OPERATE DECON WATER NLB PUMP 820303 003191 C20H001 RB SUPPORT ACTIVITY 8 HP 0.005 46.08 RB ENTRY SUPPORT

$820303 003191 C20H001 RB SUPPORT ACTIVITY 3 OP 0.007 3.50 RB ENTRY SUPPORT

  • 820303 003191 C20H001 RB SUPPORT ACTIVITY 30 CN 0.032 127.70 RB ENTRY SUPPORT 820305 003200 C30G016 CECON E X P-LP/HP-305
  • 13 CN 0.010 51.83 O PE R A T E HYDROLASER PUMP
  • 82G305 003200 C30G016 DECON E X P-L P/HP-305
  • 1 OP 0.000 0.33 OPERATE HYDROLASER PUMP 820305 003202 C30G001 DECON EXP-SDS SURVEY 8 CN 0.020 21.50 REPLACE PULSATION DAMPENER 820308 C03211 C20H001 RB SUPPORT ACTIVITY 16 CN 0.045 70.21 RB ENTRY SUPPORT
  • 820308 003211 C20H001 RB SUPPORT ACTIVITY 2 CH 0.000 12.92 RB ENTRY SUPPORT
  • 820308 003211 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 11.50 RB ENTRY SUPPORT 820308 003212 C30G001 DECON EXP-SDS SURVEY 9 HP 1.280 23.15 HP SURVEYS /OECON EXPERIMENT COVERAGE
  • 820308 003212 C30G001 DECON E XP-SDS SURVE Y 1 CN 0.065 3 08 HP SURVE YS/DECON E XPERIME NT COVERAGE 820308 003214 C30G018 DECON EXP LP MX/CANL 6 CR 1.392 12.42 LP FLUSH OF D RINGS & REFUEL POOL AREA
  • 820308 003214 C30G018 DECON EXP LP MX/CANL 7 HP 1.722 15.41 LP FLUSH OF D RINGS & REFUEL POOL AREA 820308 003236 C20H001 RB SUPPORT ACTIVITY 15 CN 0.018 38.08 DECON ANTEROOM AND AIRLOCK s

820310 003247 C20H001 RB SUPPORT ACTIVITY 2 OP 0.002 3.00 RB ENTRY SUPPORT hJ *820310 003247 C20H001 RB SUPPORT ACTIVITY 51 CN 0.079 234.76 RB ENTRY SUPPORT 00 *820310 003247 C20H001 RB SUPPORT ACTIVITY 6 CH 0.000 39.34 RB ENTRY SUPPORT

  • 820310 003247 C20H001 RB SUPPORT ACTIVITY 4 HP 0.000 32.67 RB ENTRY SUPPORT 820310 003248 C30G019 DECON EXP-LP/HP 347*

1 CR 0.000 0.25 LOW PRESSURE FLUSH OF 347* LEVEL $820310 003248 C30G019 DECON EXP-LP/dP 347* 3 HP 0.895 7.33 LOW PRESSURE FLUSH OF 347' LEVEL 820311 003256 C30G019 DECON EXP-LP/HP 347' 4 CN 0.008 9.25 DECON/ REPAIR HiDROLASER LANCES 820311 003257 C30G019 DECON EXP-LP/HP 347' 9 CR 1.875 20.20 HIGH PRESSURE FLUSH OF 347' LEVEL

  • S20311 003257 C30G019 DECON EXP-LP/HP 347' 7 HP 1.334 14.55 HIGH PPESSURE FLUSH OF 347' LEVEL
  • 820311 003257 C3CG019 DECON EXP-LP/MP 347' 2 UM 0.438 3 75 HIGH PRESSURE FLUSH OF 347' LEVEL 820315 003275 C30G016 DECON EXP-LP/HP-305*

5 CR 2.420 10 42 LDW PRESSURE FLUSH OF 305* LEVEL

  • 820315 003275 C30G016 DECON EXP-LP/HP-305*

1 UM 0.360 2.25 LOW PRESSURE FLUSH OF 305* LEVEL 820315 003276 C20H001 RB SUPPORT ACTIVITY 14 HP 0.043 88.25 RB ENTRY AND DECON EXP. SUPPORT

  • 820315 003276 C20H001 RB SUPPORT ACTIVITY 56 CN 0.133 217.70 RB ENTRY AND DECON EXP. SUPPORT

$820315 003276 C20H001 RB SUPPORT ACTIVITY 3 CH 0.005 17.42 RB ENTRY AND DECON EXP. SUPPORT

  • 820315 003276 C20H001 RB SUPPORT ACTIVITY 2 OP 0.002 0.00 RB ENTRY AND DECON EXP. SUPPORT
  • 820315 003276 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 2.00 RB ENTRY AND DECON EXP. SUPPORT 820315 003279 C30G001 DECON EXP-SDS SURVEY 6 HP 0 773 15.23 HP SURVEYS /DECON EXPERIMENT COVERAGE
  • 820315 003279 C30G001 DECON EXP-SDS SURVEY 2 CN 0 072 4.70 HP SURVEYS /DECON EXPERIMENT COVERAGE 820315 003280 C30G019 DECON EXP-LP/HP 347' 9 CR 1.470 15.97 HIGH PRESSURE FLUSH DATA ACQUISITION 8820315 003280 C30G019 DECON EXP-LP/HP 347*

1 HP 0.242 1.83 HIGH PRESSURE FLUSH DATA ACQUISITION 820315 003281 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 19.62 OPERATE HYDROLASER PUMP 820317 003308 C30G016 DECON EXP-LP/HP-305* 9 CR 3.405 11.67 HIGH PRESSURE FLUSH OF 305* LEVEL

  • 820317 003308 C30G016 DECON EXP-LP/HP-305*

1 UM 0.640 1.83 HIGH PRESSURE FLUSH OF 305* LFVEL

  • 820317 003308 C30G016 DECON EXP-LP/HP-305*

1 HP 0.612 1.93 HIGH PRESSURE FLUSH OF 305* LEVEL 820318 003322 C30G010 DECON E XP-CLE ANUP 4 CR 1.594 9.33 REMOVE TRASH 820319 003326 C30G016 DECON EXP LP/HP-305* 3 CR 0.864 4.50 LOW PRESSURE FLUSH - 305* FLOOR 820322 0023t1 C30G009 DECON EXP-SERVICES 2 CN 0.220 3.58 INSTALL SERVICE AIR HOSES 820322 003342 C30G002 DECON EXP-GAMMA SPEC 9 CN 1.792 15.97 RIG EQUIP. FROM DECON TEST - 305* & 347' 820322 003343 C30G002 DECON EXP-GAMMA SPEC 3 CN 1.226 9.00 GAMMA SPEC & R0-2A MEAS / PLACE TLDS

DATE 022486 PAGE 14 PNO. 13 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • ........ U.MB. E R. NUMB E R.........

.............Y........

  • DATE

.N ACTIVIT ENTR . CODE. REM .............. HOURS...............................IPTION TASK DESCR

  • 820322 003343 C30G002.DECON EXP-GAMMA SPM I CR

. 0.378 3.08 GAMMA SPEC & RO-2A MEAS / PLACE TLDS 820322 003356 C20H001 RB SUPPORT ACTIVITI 58 CN 0.107 206.71 RB ENTRY AND DECON E XP. SUPPORT

  • 820322 003356 C20H001 RB SUPPORT ACTIVITY 15 HP 0.004 57.92 RB ENTRY AND DECON fXP. SUPPORT
  • 820322 003356 C20H001 RS SUPPORT ACTIVITV 2 UM 0.000 1.67 RB ENTRY AND DECON EXP. SUPPORT
  • 820322 003356 C20H001 RB SUPPORT ACTIVITY 5 OP 0.005 7.50 RB ENTRY AND DECON EXP. SUPPORT

$820322 003356 C20H001 R8 SUPPORT ACTIVITY 1 SE 0.002 1.67 RB ENTRY AND DECON E XP. SUPPORT $820322 003356 C20H001 RB SUPPORT ACTIVITY 1 MM 0.000 0.83 RB ENTRY AND DECON EXP. SUPPORT 820322 003365 C30G016 DECON EXP LP/HP-305* 1 CN 0.000 4.33 OPERATE NLB HYDROLASER PUMP 820322 003366 C30G020 DECON EXP-MECH SCRUB 3 AD 0.424 8.42 MECHANICAL FLOOR SCRUBBER TEST-347* ELEV 820324 003367 C30G003 DECON EXP-DATA ACQUI 1 CN 0.071 1.67 POST-DECON PHOTOGRAPHS 820324 003368 C30G021 DECON EXP-STRIP COAT 7 CN 2.720 20.22 STRIPPABLE COATING TEST-347'&305' LEVELS 820325 00337 C30G007 DECON EXP-VIDEOTAPE 2 CN 0.740 6.42 VIDEOTAPE DECON OPERATIONS

  • S20325 00337 C30G007 DECUN EXP-VIDEOTAPE 2 CR 0.724 6.63 VIDEOTAPE DECON OPER ATIONS 820325 003379 C30G003 DECON EXP-DATA ACQUI 1 HP 0.246 2.67 COLLECT SURFACE DEPOSITION SAMPLES
  • 820325 003379 C30G003 DECON EXP-DATA ACQUI 5 OP 1.228 11.07 COLLECT SURFACE DLPOSITION SAMPLES
  • 820325 003379 C30G003 DECON EXP-DATA ACQUI 6 CN 1.693 12.36 COLLECT SURFACE DEPOSITION SAMPLES 820326 001401 C20Hn01 RB SUPPORT ACTIVITY I CN 0.005 1.50 CLOSE WDG - V100A & WDG VITA
  • 820326 003801 C20H001 RB SUPPORT ACTIVITY I OP 0.010 1.75 CLOSE WDG - V100A & WDG V17A 820330 003422 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 4.00 DECON ANTEROOM, AIRLOCK & EQUIPMENT
  • 820330 003422 C20H001 RB SUPPORT ACTIVITY 19 CN 0.066 43.92 DECON'ANTER00M. AIRLDCK & EQUIPMENT 8

820331 003436 C20H001 RB SUPPORT ACTIVITY 1 HP 0.180 2.67 HP SURVEYS & COVERAGE N f *820331 003437 C20H001 P8 SUPPORT ACTIVITY 13 CN 0.140 38.83 F9 ENTRY SUPPORT 820331 003437 C20H001 PB SUFPORT ACTIVITY 1 CH 0.005 2.92 HB ENTRY SUPPORT

  • 820331 003437 C20H001 RB SUPPORT ACTIVITY

! OP 0.000 1.25 RB ENTRY SUPPORT

  • 820331 003437 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 6.58 RB ENTRY SUPPORT
  • 820331 003437 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 6.50 RB ENTRY SUPPORT 820331 003438 C30G007 DECON EXP-VIDEOTAPE 1 CN 0.097 1.58 POST-DECON OPERATIONS 820331 003439 C30G010 DECOW EXP-CLEANUP 7 CN 2.337 17.55 REMOVE TRASH 820405 003480 C20H001 RB SUPPORT ACTIVITY 30 CN 0.120 97.91 DECON ANTER0OM, AIRLOCK. EQUIP. & TOOLS
  • 820405 003480 C20H001 RB SUPUePT ACTIVITY 2 OP 0.000 2.67 E ECON ANTE APOM. AIRLOCK, EQUIP. & TOOLS
  • 820405 003480 C20H001 RB SUPPCR T ACTIVITY 3 HP 0.000 8.50 DECON ANTEROOM. AIRLOCK, EQUIP. & TOOLS 820409 003521 C20H001 RB SUPPORT ACTIVITY 22 CN 0.040 74.10 CONSTRUCT CONTAMINATION CNIRL CORRIDOR 820414 003564 C20H001 RB SUPPORT ACTIVITY 14 CN 0.038 28.62 RB ENTRY SUPPORT
  • 820414 003564 C20H001 RB SUPPORT ACTIVITY 1 MM 0.005 0.25 RB E NTRY SUPPORT
  • 820414 003564 C20H001 RB SUPPORT ACTIVITY 3 OP 0.006 5.92 RB ENTRY SUFPORT
  • 820414 003564 C20H001 RB SUPPORT ACTIVITY 1 CH 0.005 2.50 RB ENTRY SUPPOR T
  • 820414 003564 C7"N001 RB SUPPORT ACT!v!TY 4 HP 0.000 12.33 RB ENTRY SUPPORT 820414 003577 C40H001 RB SUPPORT ACTIVITY 1 HP 0.000 3.00 RB E NTRY AND E XIT SUPPORT
  • 820414 003s77 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 1.50 RB ENTRY AND EXIT SUPPORT
  • 820414 003577 C20H001 RB SUPPORT ACTIVITY 3 CN 0.020 9.50 RB ENTRY AND EXIT SUPPORT 820414 003578 C50H001 RB P.M. AND SURVEY 2 MM 0.316 3.50 REPAIR OR REPLACE AIRLOCK SEALS
  • 820414 003578 C50H001 RB P.M.

AND SURVEY ! CN 0.100 1.75 REPAIR OR REPLACE AIRLOCK SEAIS 820414 003584 C20H001 RB SUPPORT ACTIVITY 27 CN 0.027 92.50 CONST CONTAMINATION CNTRL CORR-ANTEROOM 820414 003585 C20H001 RB SUPPORT ACTIVITY 16 CN 0.025 56.45 DECON TOOLS & EQUIP IN ANTEROOM 820415 003590 C50H001 RB P M AND SURVEY 2 CN 0.050 1.67 WALKDOWN NITROGEN BLANKri SYSTEM 820422 003641 C30G022 DECON E XP-HPR214 RMV 6 CN 1.462 15.42 REMOVE HPR-214

  • 820422 003641 C30G022 DECON EXP-HPR214 RMV 1 HP 0.130 0.28 REMOVE HPR-214 820422 003642 C30G002 DECON E X P-GAMMA SPEC 2 CN 0.422 3.67 REMOVE TLD'S 820422 003644 C20H001 RB SUPPORT ACTIVITY 13 CN 0.040 51.68 RB ENTRY SUPPORT
  • 820422 003644 C20H001 RB SUPPORT ACTIVITY 2 CH 0.000 12.33 RB ENTRY SUPPORT

DATE 022486 PAGE 15 PNO. 14 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS.0EPT . EXPOS. TIME s..... .............................. TASK DE.SCRIPTION ACTIVITY . ENTR. CODE. REM . HOURS

  • DATE. NUMBE.R. NUMBER............................................
  • 820422 003644 C20H001 RB SUPPORT ACTIVITY 3 HP 0.000. 14 58

.RB ENTRY SUPPOR)

  • 820422 003644 C20H001 RB SUPPORT ACTIVITY 1 MM 0.015 1.58 RB ENTRY SUPPORT 820423 003655 C20H001 RB SUPPORT ACTIVITY 8 CN 0.015 16.08 DECON ANTEROOM & AIRLOCK 820426 003673 C20H001 RB SUPPORT ACTIVITY I OP 0.000 1.42 DECON ANTER00M, AIRLOCK. TOOLS & EQUIP

$820426 003673 C20H001 RB SUPPORT ACTIVITY 13 CN 0.018 42.71 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP 820426 003674 C20H001 RB SUPPORT ACTIVITY 3 CN 0.005 7.17 MODIFY CONTAMINATION CONTROL CORRIDOR 820428 003697 C20H001 RB SUPPORT ACTIVITY 11 CN 0.016 50.00 RB ENTRY SUPPORT

  • 820428 003697 C20H001 RB SUPPORT ACTIVITY 1 RC 0.003 5.00 RB ENTRY SUPPORT
  • 82C428 003697 C20H001 RB SUPPORT ACTIVITY 3 HP 0.002 18.75 RB ENTRY SUPPORT
  • 820428 003697 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 2.33 RB ENTRY SUPPORT 820428 003699 C50H001 RB P.M. AND SURVEY 2 OP 0.653 3.17 TEST SMOME DETECTORS 820428 003700 C50H001 RB P.M. AND SURVEY 1 MD 0.127 2.67 INSPECT AIRLOCK Dv0RS
  • S20:28 003700 C50H001 RB P.M.

AND SURVEY 1 I44 0.124 2.67 INSPECT AIRLOCK DOORS 820428 003701 C300005 DECON EXP-CCTV RELOC 1 IC 0.302 2.67 CCTV REPA!R

  • 820428 003701 C30G005 DECON EXP-CCTV RELOC 1 CN 0 322 2.67 CCTV REPAIR 820428 003703 C30G010 DECON E XP-CLE ANUP 2 CN O 363 3.00 STAGE TR ASH FOR REMOVAL 820503 003751 C20H001 RB SUPPORT ACTIv!TY 2 CN 0 G00 8,00 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP 820503 003753 C20H001 RB SUPPORT ACTIVITY 2 CN O 008 7.67 MODIFY CONTAMINATION CONTROL CORRIDOR 820504 006423 C30G007 DECON EXP-VIDEOTAPE 2 CN 0.336 4.12 PHOTOGRAPH / INSPECT SNUBBERS & HANGERS 820505 003764 C20H001 RB SUPPORT ACTIVITY 7 CN 0.035 29.67 RB ENTRY SUPPORT C3 *820505 003764 C20H001 RB SUPPORT ACTIVITY 5 HP 0.000 24.75 RB ENTRY SUPPORT w

e

  • 820505 003764 C20H001 RB SUPPORT ACTIVITY 3 OP 0.015 6.50 RB ENTRY SUPPORT 820505 003766 C30G010 DECON EXP-CLEANUP 2 CN 0.267 4.58 REMOVE WASTE. SAMPLERS & CCTV CCNTROLS 820510 003804 C45H001 RB CORRECTIVE MAINT 2 CN 0.351 3.45 MODIF Y LIFT RIG 820510 003806 C20H001 RB SUPPORT ACTIVITY 9 CN 0.011 34.00 RB ENTRY SUPPGRT
  • 820510 003806 C20H001 RB SUPPORT ACTIVITY 6 HP 0.145 31.42 RB ENTRY SUPPOR'

$820510 003806 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 2.00 RB CNTRY SUPPOR* 820511 003824 C20H001 EB SUPPORT ACTIVITY 7 CN 0.009 24.36 DECON ANTEROOM. TOOLS & EQUIP 820511 003824 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.12 DECON ANTEROOM. TOOLS & EQUIP 820513 003839 C20H001 RB SUPPORT ACTIVITY 18 CN 0.021 57.90 RB ENTRY SUPPORT

  • 820513 003839 C20H001 RB SUPPORT ACTIVITY 4 HP O.005 25.83 RB ENTRY SUFPORT
  • 820513 003839 C20H001 RB SUPPORT ACTIVITY 2 OP 0.005 3.17 RB ENTRY SUPPORT 820513 003842 C30G003 DECON EXP-DATA ACOUI 1 ES 0.125 1.53 REMOTE SURVEY OF

'D' RINGS 820513 003845 C30G002 DECON EXP-GAMMA SPEC 1 CN 0.127 1.20 REMOVE IODINE SAMPLERS 820518 003901 C20H001 RB SUPPORT ACTIVITY $ CN 0.015 14.25 DECON ANTEROOM. T0uLS & EQUIP

  • 820518 003901 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.33 DECON ANTEROOM. TOOLS & EQUIP 820526 003950 C30G010 DECON EXP-CLEANUP 2 CN 0.341 2.75 CLE AN STAGING ARE A/TRANSF ER LIQUIDS 820526 003951 C50H001 RB P.M.

AND SURVEY 2 OP 0.500 3.67 TEST SMOFE DETECTORS 820526 003953 C30G014 DECON EXP-P.C. SPIDR 3 CN 0.613 9.67 EQUIPMENT MAINTENANCE 820526 003954 C20H001 RB SUPPORT ACTIVITY 16 CN 0.013 56.95 RB ENTRY SUPPORT

  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 4.08 RB ENTRY SUPPORT
  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 1 ES 0.000 0.50 RB ENTRY SUPPORT
  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 1 RC 0.005 9.67 RB ENTRY SUPPORT
  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 3 HP 0.003 30.25 RB ENTRY SUPPORT 820526 003959 C20H001 RB SUPPORT ACTIVITY 10 CN O.072 32.25 DECON ANTE ROUM. AIRLOCK. TOOLS & EQUIP 820601 0u3992 C20H001 RB SUPPORT ACTIVITY 3 CN 0.010 9.67 MODIFY CONTAMINATION CONTROL CORRIDOR 820602 004007 C20H001 RB SUPPORT ACTIVITY 9 CN 0.010 24.75 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP

$820602 004007 C20H001 RB SUPPORT ACTIVITY 1 RC 0.005 3 58 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP 820603 003996 C30G022 DECON EXP-HPR214 RMV 4 CN 0.134 5.00 R E MOVE HPR-214 F ROM RB 820603 003997 C30G005 DECON EXP-CCTV RELOC 2 CN 0.326 4.83 RELOCATE CCTV l

l l DATE 022486 PAGE 16 PNO. 15 .THI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK, PERS. DEPT. EXPOS. TIME ACT ENTR. CODE. REM TASK DESCRIPTION

  • ............................r...IVIT.Y

.............,.......H.OURS..................................................

  • DATE. NUMBER. NUMBER
  • 820603 003997 C30G005 DECON EXP-CCTV RELOC 1. IC 0.207......

2 41 RELOCATE CCTV 820603 004000 C20H001 RB SUPPORT ACTIVITY 13 CN 0.032 50.57 RB ENTRY SUPPORT

  • 820603 004000 C20H001 RB SUPPORT ACTIVITY 2 RC 0.000 11.25 RB ENTRY SUPPORT
  • 820603 004000 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 8.13 RB ENTRY SUPPORT 820004 004009 C20H001 RB SUPPORT ACTIVITY 3 CN 0.015 7.33 REPAIR OR REPLACE LICHTS & LIMIT SWITCH
  • 820604 004009 C20H001 RB SUPPORT ACTIVITY 4 EL 0.013 14.25 REPAIR OR REPLACE LIGHTS & LIMIT SWITCH
  • 820604 004009 C2CH001 RB SUPPORT ACTIVITY 2 MD 0.032 8.25 REPAIR OR REPLACE LIGHTS & LIMIT SWITCH 820610 004037 C20H001 RB SUPPORT ACTIVITY 11 CN 0.022 43.40 RB ENTRY SUPPORT
  • 820610 004037 C20H001 RB SUPPORT ACTIVITY 5 HP 0.000 26.67 RB ENTRY SUPPORT

$820610 004037 C20H001 RB SUPPORT ACTIVITY 1 RC 0.000 0 08 RB ENTRY SUPPORT 820610 004038 C30G003 DECON E XP-DATA ACQUI 2 CN O.334 3.33 POST-DECON DATA ACQUISITION 820617 004087 C20H001 RB SUPPORT ACTIVITY 11 CN 0.023 31.63 RB ENTRY SUPPORT

  • 820617 004087 C20H001 RB SUPPORT ACTIVITY 7 HP 0.010 34.07 RB ENTRY SUPPORT

$820617 004087 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 2.25 RB ENTRY SUPPORT 820617 004088 C90K001 RB DATA ACQUISITION 1 HP 0.209 1.72 SURVE Y,IDENTIF Y, PHOTO FLOOR PENETS-305'

  • 820617 004088 C90K001 RB DATA ACQUISITION 2 CN 0.687 4.58 SURVEY, IDENTIFY. PHOTO FLOOR PENETS-305' 820617 004089 C90K001 RB DATA ACQUISITION 2 HP 0.688 3.60 HP SURVEY / PLACE TLD TREE 820622 004121 C90K001 RB DATA ACQUISITION 2 HP 0.311 4.17 TLD PLACEMENT /HP SURVEYS 820622 004122 C90K001 RB DATA ACQUISITION 3 CN 0.887 4.42 REMOVE HATCH PL UG F OR TLD PLACEMENT 820622 004123 C30D001 RB DECON-282
  • EL EV 1 CR 0.224 2.50 REMOTE DECON OF WALLS ON 282* LEVEL RB DECON-282' ELEV 10 CN 1.648 19.58 REMOTE DECON OF WALLS ON 282' LEVEL b.*820622004123C30D001 820622 004124 C50H001 RB P.M AND SURVEY 3 CN 0.411 5.17 SPIDER CHK/ STAGE POWER BUGGY / ADD LIGHTS 820622 004126 C20H001 RB SUPPORT ACTIVITY 25 CN 0.049 84.18 RB ENTRY SUPPORT e *820622 004126 C20H001 RB SUPPORT ACTIVITY 11 HP 0.069 71.63 RB ENTRY SUPPORT 820622 004131 C90K001 RB DATA ACQUISITION I HP 0.384 1.00 CBTAIN SCRAPE SAMPLE-Ft90R 282* LEVEL
  • 820622 004131 C90K001 RB DATA ACQUISITION 1 CN 0.289 1.00 OBTAIN SCRAPE SAMPLE-FLOOR 282* LEVEL 820623 004132 C50H001 RB P.M. AND SURVEY 1 CN 0.123 1.58 INSTL ACOUS MONITORS ON CRDM MONIT TUBE
  • 820623 004132 C50H001 RB P.M.

AND SURVEY 2 IC 0.268 3.17 INSTL ACOUS MONITORS ON CRDM MONIT TUBE 820623 004133 C90K001 RB DATA ACQUISITION 3 HP 0.425 6.92 HP SURVE Y AND CGVE RAGE 820623 004134 C45H001 RB CORRECTIVE MAINT 1 EL 0.467 3.00 PERSONNE L AIRLOCKS MAINTENANCE

  • 820623 004134 C45H001 RB CORRECTIVE MAINT 2 MM 0.736 6.08 PERSONNEL AIRLOCKS MAINTENANCE 820624 004143 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.75 LEAK CHECK DOORS
  • 820624 004143 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.75 LEAK CHECK DOORS 820624 004149 C20H001 RB SUPPORT ACTIVITY 8 CN 0.015 15.25 DECON ANTERDOM. AIRLOCK, TOOLS & EQUIP 820630 004187 C20H001 RB SUPPORT ACTIVITY 12 CN 0.047 38.25 RB ENTRY SUPPORT
  • 820630 004187 ( 20H001 RB SUPPORT ACTIVITY 7 HP 0.009 48.65 RB ENIRY SUPPORT

$820630 004187 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.83 RB ENTRY SUPPORT

  • 820630 004187 C20H001 RB SUPPORT ACTIVITY 1 MM 0.000 0.75 RB ENTRY SUPPORT 820630 004188 C90K001 RB DATA ACQUISITION 2 HP 0.140 3 02 HP SURVE Y AND COVE R AGE 820630 004189 C20H001 RB SUPPORT ACTIVITY 2 CN 0.164 4.83 TOOL INVENTORY & STORAGE 820701 004196 C20H001 RB SUPPORT ACTIVITY 2 OP 0.018 1.67 OPER ATE F SV-639 DURING RB ENTRY
  • 820701 004196 C20H001 RB SUPPORT ACTIVITY 2 HP 0.025 1.50 OPE R AT E FSV-639 DURING RB ENTRY 820702 004202 C20H001 RB SUPPORT ACTIVITY 14 CN 0.012 23.53 GENERAL DECON & CLEANUP

$820702 004202 C20H001 RB SUPPORT ACTIVITY 2 HP 0.010 7.17 GENERAL DECON & CLEANUP 820706 004221 C45H001 RB CORRECTIVE MAINT 1 HP 0.005 1.25 REPAIR AIR LIMIT SWITCH AND LIGHTS

  • 820706 004221 C45H001 RB CORRECTIVE MAINT 2 EL 0.000 2.33 REPAIR AIR LIMIT SWITCH AND LIGHTS
  • 820706 004221 C45H001 RB CORRECTIVE MAINT 1 IC 0.000 0.75 REPAIR AIR LIMIT SWITCH AND LIGHTS

$820706 004221 C45H001 RB CORRECTIVE MAINT 1 MD 0.000 1.17 REPAIR AIR LIMIT SWIT H AND LIGHTS 820707 004231 C30G010 DECON E XP-CLE ANUP 2 CN 0.355 3.08 TRASH CLEANUP 820707 004232 C30G010 DECON EXP-CLEANUP 2 CN 0.627 2.83 TRASH CLEANUP

DATE 022486 PAGE 17 PNO 16 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCF. PERS. DEPT. EXPOS. TIME ...... HOURS..........................ESCRIPTION TASK D

  • DATE... NUMBER.NUMBE.R..............IVI.TY............................EM ACT ENTR. CODE

.R 3.... 2 CN . 0.300 2.50 TOOL INVENTORY 820707 004233 C30G010 DECON EXP-CLEANUP 820707 004234 C30G015 DECON EXP-SPIDER-347 2 CN 0.102 2.33 SPIDER LIFT MAINTENANCE 820707 004235 C20H001 RB SUPPORT ACTIVIfY 11 CN 0.010 27.66 RB ENTRY SUPPORT

  • 820707 004235 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 2.50 RB ENTRY SUPPORT
  • 82D707 004235 C20H001 RB SUPPORT ACTIVITY 9 HP 0.000 53.72 RB ENTRY SUPPORT
  • 820707 004235 C20H001 RB SUPPORT ACTIVITY

! IC 0.005 1.17 RB ENTRY SUPPORT 820709 004244 C45H001 RB CORRECTIVE MAINT 2 HP 0.007 9.25 REPLACE DP SWITCH IN PERS ACCESS HATCH $820709 004244 C45H001 RB CORRECTIVE MAINT 2 IC 0.041 6.50 REPLACE DP SWITCH IN PERS ACCESS HATCH

  • 820709 004244 C45H001 RB CORRECTIVE MAINT 1 OP 0.000 6.25 REPLACE DP SWITCH IN PERS ACCESS HATCH 820709 004245 C45H001 RB CORRECTIVE MAINT 2 MM 0.020 4.00 REPLACE DOOR SEAL-EQUIP HATCH OUTER DOOR 820709 004246 C45H001 RB CORRECTIVE MAINT 1 IC 0.025 3.50 REPLACE OP SWITCHES - EQUIP HATCH ACCESS 820712 004263 C20H001 RB SUPPORT ACTIVITY 43 CN 0.157 135.63 RB ENTRY SUPPORT
  • 820712 004263 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 1.75 RB ENTRY SUPPORT
  • 820712 004263 C20H001 RB SUPPORT ACTIVITY 29 HP 0.010 162.17 RB ENTR? SUPPORT
  • S20712 004263 C20H001 RB SUPPO.tT ACTIVITY 2 AM 0.000 0.38 RB ENTRY SUPPORT 820712 004264 C70K002 TLD TREES - 282' 2 CN 0.833 3.92 OPEN FLOOR PENETRATION FOR DECON 820712 004265 C30E001 DECON RB D RINGS 4 CN 1.078 8.92 PEMOTE FLUSH OF

'D' RING 820712 004266 C30D001 RB DECON-282* ELEV 2 CN 0.080 2.17 REMOTE FLUSH - 282* LEVEL 820712 004267 C20H001 RB SUPPORT ACTIVITY 3 HP 0.496 4.92 HP SURVEY & COVERAGE 820712 004270 C30G010 DECON E XP-CLE ANUP 1 CN 0.005 6.50 OPERATE AND MAINTAIN NLB PUMP I 820715 004291 C20H001 RB SUPPORT ACTIVITY 1 HP 0.075 0.17 GENERIC HP SURVEY W RB - CCTV 3 IC 0.000 10.42 REPAIR / MODIFY CCTV CAMERA & CONTROLS 7*820716004301C20H002 820716 004301 C20H002 RB - CCTV 1 HP 0.000 2.00 RE PAIR /MODIF Y CCTV CAME R A t CONTROLS

  • 820716 004301 C20H002 RB - CCTV 1 CN 0.000 4.00 REPAIR / MODIFY CCTV CAMERA & CONTROLS 820719 004317 C20H001 RB SUPPORT ACTIVITY 35 CN 0.173 112.90 RB ENTRY SUPPORT
  • 820719 004317 C20H001 RB SUPPORT ACT LVITY 18 HP 0.008 139.50 RB ENTRY SUPPORT
  • 820719 004317 C20H001 RB SUPPORT ACTIVITY

! MM 0.010 1.17 RB ENTRY SUPPORT

  • 820719 004317 C20H001 RB SUPPORT ACTIVITY 1 CR 0.000 0.50 RB ENTRY SUPPORT

$820719 004317 C20H001 RB SUPPORT ACTIVITY 1 OP 0.003 0.67 RB ENTRY SUPPORT

  • 820719 004317 C20H001 RB SUPPORT ACTIVITY 1 AM 0.000 0.33 RB ENTRY SUPPORT 820721 004336 C20H001 RB SUPPORT ACTIVITY

! HP 0.017 1.00 GENERIC RADIOLOGICAL SURVEY 820726 004358 C20H001 RB SUPPORT ACTIVITY 4 CN 0.010 6.83 RELOCATE CAMERA / REMOVE PLEXIGLASS WALL 820727 004374 C20H001 RB SUPPORT ACTIVITY 4 CN 0.045 8.57 RB ENTRY SUPPORT 820727 004376 C20H001 RB SUPPORT ACTIVITY 1 HP 0.105 1.00 SLUDGE SAMPLE SURVEY /CCVERAGE 820727 004377 C90K001 RB DATA ACQUISITION 5 CN 0.613 7.42 $NUBBER DISASSEMBLY AND REMOVAL 820727 004378 C30D001 RB DECON-282' ELEV 4 CN 0.229 9.58 REMOTE DECON - 282* LEVEL 820727 004380 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 8.33 OPERATE NLB PUMP 820727 004383 C90K001 RB DATA ACQUISITION 2 CN 0.000 0.75 MOVE SNUBBERS-ANTEROCM TO MODEL ROOM

  • 820727 004383 C90K001 RB DATA ACQUISITION 1 HP 0.000 1.33 MOVE SNUBDERS-ANTEROOM TO MODEL ROOM 820728 004379 C20H001 RB SUPPORT ACTIVITY 15 CN 0.020 33.48 RB ENTRY SUPPORT
  • 820728 004379 C20H001 RB SUPPORT ACTIVITY 9 HP 0.020 48.33 RB ENTRY SUPPORT

$820728 00e9 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.67 RB ENTRY SUPPORT 820728 00434. C90K001 RB DATA ACQUISITION 3 CM 0.048 7.25 TRANSPOR T SAMPLE TO SDS MRFGB AND L AB

  • 820728 004385 C90K001 RB DATA ACQUISITION 1 HP 0.015 2.42 TRANSPORT SAMDLE TO SDS HRFGB AND LAB
  • 820728 004385 C90K001 RB DATA ACQUISITION 1 UM 0.010 1.58 TRANSPORT SAMPLE TO SDS HRFGB AND LAB r820728 004385 C90K001 RB DATA ACQUISITION 1 CR 0.005 0.75 TRANSPORT SAMPLE TO SDS HRFGB AND LAB
  • 820728 004385 C90K001 RB DATA ACQUISITION 1 CN 0.008 1.42 TRANSPORT SAMPLE TO SDS HRFGB AND LAB 820730 004401 C30G003 DLCON EXP-DATA ACQUI 1 DM 0.005 0.25 CPEN DRUM IN COMPACTOR ROOM 820803 004418 C20H001 RB SUPPORT ACTIVITY

? CN 0.005 3.75 OPERATE NLB PUMP 820803 004427 C20H001 RB SUPPORT ACTIVITY 3 CN 0.397 5.25 STAGE MATERIAL / REMOVE TRASH

_m-I i a DATE 022486 PAGE 18 PNO 17 .TMI-2 UNC:. DDS - ACTIVITY REPORT-RE.*CTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT, EXPOS. TIME ..URS.........,... T. A S. K D E.SC.R. I P T I O.N ......... T I V I T. Y..................E.N T R..... C OD E...,. R E M

  • D ATE... NUMB.E R. NUMB.E.R....AC....

.HO g.... 820803 004428 C20H001 RB SUPPORT ACTIVITY 1 HP 0,146 2.17 HP SURVEY-GEN. AREA & SERV. STRUCTURE-. 820804 004435 C20H001 RB SUPPORT ACTIVITY 45 CN 0.060 147.13 RB ENTRY SUPPOR7

  • 820804 004435 C20H001 RB SUPPORT ACTIVITY 23 HP 0.077 136.77 RB ENTRY SUPPORT
  • 820804 004435 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 0.83 RB ENTRY SUPPORT 820804 004436 C20H001 RB SUPPORT ACTIVITY 15 CN 0.184 31.08 RB ENTRY SUPPORT 820809 004458 C45H001 RB CORRECTIVE MAINT 7 CN 0.005 11.50 REPAIR CONTAMINATION CONTROL CORRIDOR 820811 004467 C20H001 RB SUPPORT ACTIVITY 7 CN 0.118 14.72 RB ENTRY SUPPORT 820811 004468 C20H001 RB SUPPORT ACTIVITY 21 CN 0.067 55.97 RB ENTRY SUPPORT
  • 820811 004468 C20H001 RB SUPPORT ACTIVITY 18 HP 0.040 109.65 RB ENTRY SUPPORT
  • 820811 004468 C20H001 - RB SUPPORT ACTIVITY 2 OP 0.007 4.50 RB ENTRY SUPPORT
  • 820811 004468 C20H001 RB SUPPORT ACTIVITY 2 AM 0.000 0.55 RB ENTRY SUPPORT
  • 820811 004468 C20H001 RB SUPPORT ACTIVITY 1 CR 0.005 1.25 RB ENTRY SUPPORT 4

820812 004487 C20H001 RB SUPPORT ACTIVITY 3 CN 0.005 1.27 TRASH REMOVAL 820812'004488 C20H001 RB SUPPORT ACTIVITY 1 HP 0.026 0.50 HP SURVEY & ENTRY COVERAGE 820812 004490 C30G003 DECON EXP-DATA ACQUI 2 CN 0.248 3.00 POST-DECON DATA ACQUISITION-STRIPCDAT 820812 004491 C90K001 RB DATA ACQUISITION 2 CN 0.210 4.12 REMOVE SOLENOID AHVG 820813 004495 C45H001 RB CORRECTIVE MAINT 2 MM 0.286 2.75 MAINTENANCE ADJUSTMENT OF AIRLOCK 820813 004496 C20H001 RB SUPPORT ACTIVITY 4 CN 0.423 5.75 TRASH REMOVAL

  • 820813 004496 C20H001 RB SUPPORT ACTIVITY 1 CR 0.157 1.42 TRASH REMOVAL I

RB SUPPORT ACTIVITY 1 HP 0.010 0.50 HP SURVEY b *820813 004498 C20H001 820816 004501 C20H001 RB SUPPORT ACTIVITY 35 CN 0.069 107.64 RB ENTRY SUPPORT g3 820816 004501 C20H001 RB SUPPORT ACTIVITY 33 HP 0.057 189.50 RB ENTRY SUPPORT i

*820816 004501 C20H001 RB SUPPORT ACTIVITY 2 OP -

0.000 2.08 RB ENTRY SUPPORT

  • 820816 004501 C20H001 RB SUPPORT ACTIVITY 1 CH 0.000 0.17 RB ENTRY SUPPORT l
  • 820816 004501 C20H001 RB SUPPORT ACTIVITY 1 AM 0.000 0.33 RB ENTRY SUPPORT e
  • 820816 004501 C20H001 RB SUPPORT ACTIVITY 2 CR 0.005 5.75 RB ENTRY SUPPORT 820816 004502 C20H001 RB SUPPORT ACTIVITY 13 CN 0.242 29.75 RB ENTRY AIRLOCK SUPPORT

'820817 004516 C45H001 RB CORRECTIVE MAINT 2 CN 0.393 3.08 INSTALL WATT METER / REPLACE CAMERA 820817 004519 C30D001 RB DECON-282* ELEV 3 CN 0.194 6.17 REMOTE DECON - 282* LEVEL i 820818 004513 C20H001 RB SUPPORT ACTIVITY 12 CN 0.000 39.49 ^ OPERATE NLB PUMP

  • 820818 004513 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.33 OPER ATE NLB PUMP 820818 004515 C20H001 RB SUPPORT ACTIVITY 1 OP 0.010 0.50 OPERATE FSV-639 FOR RB ENTRY
  • 820818 004515 C20H001 RB SUPPORT ACTIVITY I HP 0.005 0.50 OPERATE FSV-639 FOR RB ENTRY 820819 004537 C30D001 RB DECON-282' ELEV 8 CN 0.335 10.12 REMOTE DECON - 282* LEVEL i

820819 004541 C20H001 RB SUPPORT ACTIVITY 1 HP 0.107 1.83 AIR SAMPLE AND TRASH REMOVAL 4820819 004541'C20H001 RB SUPPORT ACTIVITY 5 CN 0.384 3.84 AIR SAMPLE AND TRASH REMOVAL 820820 004548 C20H001 RB SUPPORT ACTIVITY 2 HP 0.112 1.43 HP SURVEY 820820 004550 C90K001 RB DATA ACQUISITION 1 HP 0.126 1.43-INSTALL POWER BUGGY / REMOVE P.C. PENDANT

  • 820820 004550 C90K001 RB DATA ACQUISITION 4 CN 0.677 7.62 INSTALL POWER BUGGY / REMOVE P.C. PENDANT

'z 820823 004555 C20H001 RB SUPPORT ACTIVITY 39 CN 0.047 152.68 RB ENTRY SUPPORT o

  • 820823 004555 C20H001 RB SUPPORT ACTIVITY 28 HP 0.022 161.57 RB ENTRY SUPPORT
  • 820823 004555 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.50 RB ENTRY SUPPORT
  • 820823 004555 C20H001 RB SUPPORT ACTIVITY 2 CR 0.000 6.17 RB ENfRY SUPPORT 820823 004556 C20H001 RB SUPPORT ACTIVITY 11 CN 0.236 22.87 RB ENTRY SUPPORT IN AIRLOCK
  • 820823 004556 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.00 RB ENTRY SUPPORT IN AIRLOCK

'820824 004565 C20H001 RB SUPPORT ACTIVITY 8 CN 0.000 9.12 REPAIR ORANGE GOOSE HYDROLASER PUMP

  • 820824 004565 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 1.33 REPAIR ORANGE GOOSE HYDROLASER PUMP 820824 004593 C90K001 RB DATA ACQUISITION 2 CN 0.332 3.80 TV SURVEY OF 282
  • ELEV.
  • 820824 004593 C90K001 RB DATA ACQUISITION 1 ES 0.292 2.47

.TV SURVEY OF 282' ELEV. j

  • 820824 004593 C90K001 RB DATA ACQUISITION 1 HP 0.139 1.42 TV SURVEY OF 282* ELEV.

i i )

.. _ _ = _ - -- -- i DATE 022486 PAGE 19 l PNO. 18, .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. A T E... NUMB.E. R. NUMB E. R..,...... AC. T. IV. I T Y......

...................E... REM........ O. U R S................ S. K D. E. SC. R I. P. T I. O. N...................... ENTR. COD .H TA w i 820825 004570 C70K002.TLD TREES - 282* 2 CN 0.303 2.45 TLD PLACEMENT BELOW 305' LEVEL 820826 004584 C30D001 RB DECON-282' ELEV 6 CN 0.034 10.90 REMOTE DECON - 282* LEVEL 820326 004587 C20H001 RB SUPPORT ACTIVITY 1 HP 0.080 1.00 HP SURVEY 820826 004594 C20H001 RB SUPPORT ACTIVITY 14 CN 0.017 51.83 OPERATE NLB PUMP & GENERAL DECON 820827 004613 C20H001 RB SUPPORT ACTIVITY 11 CN 0.015 24.20 RUN CONDUIT / INSTALL HANGERS-MODEL ROOM i 820830 004601 C20H001 RB SUPPORT ACTIVITY 2 HP 0.043 1,67 HP SURVEY 820830 004605 C20H001 RB SUPPORT ACTIVITY 9 CN 0.182 20.00 RB ENTRY SUPPORT IN AIRLOCK 820830 004606 C20H001 RB SUPPORT ACTIVITY 37 CN 0.178 113.08 RB ENTRY SUPPORT

  • 820830 004606 C209001 RB SUPPORT ACTIVITY 24 HP 0.012 129.15 RB ENTRY SUPPORT -
  • 820830 004606 C20H001 RB SUPPORT ACTIVITY 5 OP 0.010 6.92 RB ENTRY SUPPORT
  • 820830 004606 C20H001 RB SUPPORT ACTIVITY 1 VI O 000 1.08 RB ENTRY SUPPORT
  • 820830 004606 C20H001 RB SUPPORT ACTIVITY 3 CR 0.000 8.00 RB ENTRY SUPPORT O

820830 004607 C20H001 RB SUPPORT ACTIVITY 11 CN 0.064 39.83 DECON EQUIPMENT HATCH

  • 320830 004607 C20H001. RB SUPPORT ACTIVITY 1 HP 0.005 2.50 DECON EQUIPMENT HATCH 820830 004608 C20H002 RB - CCTV '

1 IC 0.000 4.50 REPAIR TV CAMERA I 820b31 004623 C30L001 DECON RB DOME 2 CN 0.333 4.08 STAGE DECON EQUIPMENT ON POLAR CRANE 820831 004642 C90K001 RB DATA ACQUISITION 1 ES 0.357 1.92 TV SURVEY OF 282' ELEV. t i 820901 004621 C20H001 RB SUPPORT ACTIVITY 8 CN 0.403 5.50 INSTALL WORK PLATFORM AND RAMP 1 MM 0.000 1.00 INSPECT EQUIPMENT AIRLOCK INNER DOOR 820901 004625 C45H001.'RB CORRECTIVE MAINT

  • 820901 004625 C45H001 RB CORRECTIVE MAINT 1 HP 0.008 3.25 INSPECT-EQUIPMENT AIRLOCK *NNER DOOR I
  • 820901 004625 C45H001 RB CORRECTIVE MAINT 1 IC 0.020 2.67 INSPECT EQUIPMENT AIRLOCK INNER DOOR 00 RB SUPPORT ACTIVITY 3 CN 0.001 13.08 NLB PUMP OPERATION & MAINTENANCE 7 '820902 004640 C20H001 820903 004643 C30D001 RB DECON-282' ELEV 3 CN 0.144 4.38 REMOTE DECON - 282* LEVEL 820903 004644 C45H001 RB CORRECTIVE MAINT 2 MM 0.270 2.33 REPAIR AIRLOCK DOORS 820907 004651 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 1.28 PULL CABLE & MAKE CONNECTIONS - MODEL RM 820907 004657 C30D001 RB DECON-282 (ELEV 4 CN 0.264 5.68 REMOTE DECCN - 282' LEVEL 820907 004658 C20H001 RB SUPPORT ACTIVITY 23 CN 0.012 65.45 RB ENTRY SUPPOR. - ANTEROOM

$820907 004658 C20H001 RB SUPPORT ACTIVITY 18 HP 0.030 96.50 RB ENTRY SUPPORf - ANTEROOM

  • 820907 004658 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0,58 RB ENTRY SUPPORT - ANTEROOM
  • 820907 004658 C20H001 RB SUPPORT ACTIVITY 2 CR 0.000 7.75 RB ENTRY SUPPORT - ANTER0OM 820907 004659 C20H001 RB SUPPORT ACTIVITY 6 CN 0.111 12.42 RB ENTRY SUPPORT - AIRLOCK.

820909 004678 C30A001-DECON POLAR CRANE 1 CM 0.182 1.75 EQUIPMENT PROTECTION

  • 820909 004678 C30A001 DECON POLAR CRANE 3 UM 0.533 5.75 EQUIPMENT PROTECTION 820909 004679 C90K001 RB DATA ACQUISITION 3 CN 0.464 5.25 WIRE SPLICE AND CABLE SAMPLING
  • 820909 004679 C90K001 RB DATA ACQUISITION 1 HP 0.195 2.17 WIRE SPLICE AND CABLE SAMPLING 820909 004680 C20H001 RB SUPPORT ACTIVITY 4 CN 1.389 6.82 INSTALL RAMP & PLATFORM - EQUIP. HATCH 820909 004681 C20H002 RB - CCTV 1 IC 0.106 1.75 REPAIR CCTV CAMERA FOR 281* ELEV INSPECT 3820909 004681 C20H002 RB - CCTV 1 HP 0.123 1.83 REPAIR CCTV CAMERA FOR 281* ELEV INSPECT 820910 004674 C20H001.RB SUPPORT ACTIVITY 3 CN 0.008 11,75 OPERATE NLB PUMP 820913 004691 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 5.41 RUN CONDUIT / TERMINATE CABLES - MODEL RM
  • 820913 004691 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.67 RUN CONDUIT / TERMINATE CABLES - MODEL RM 820914 004699 C20H001.RB SUPPORT ACTIVITY 5 CN 0.040 25.25 DECON EQUIPMENT HATCH 820914 004704 C20H001 RB SUPPORT ACTIVITY 32 CN 0.052 99.83 RB ENTRY SUPPORT
  • 820914 004704 C20H001' RB SUPPORT ACTIVITY 25 HP 0.035 119,42 RB ENTRY SUPPORT
  • 820914 004704 C20H001 RB SUPPJRT ACTIVITY 1 OP C.000 0.67 RB ENTRY SUPPORT
  • 820914 004704 C20H001 RB SUPPORT ACTIVITY 3 CR 0.040 5.08 RB ENTRY SUPPORT 820914 004705 C20H001 'RB SUPPORT ACTIVITY 10 CN 0.182 23.97 RB ENTRY SUPPORT - AIRLOCK 820915 004706 C90K001 RB DATA ACQUISITION 1 HP 0.074 1.33 REMOVE AND REPLACE PRESSURE SWITCH 3820915 004706 C90K001 RB DATA ACQUISITION 2 CN 0.204 2.92 REMOVE AND REPLACE PRESSURE SWITCH 820915 004709 C300001 RB DECON-282' ELEV 4 CN 0.477 2.87 REMOTE DECON - 282* LEVEL i

[

DATE 022486 PAGE 20 PNO 19 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING CECONTAMINATION286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. ATE...........

.............Y ....................SK DES.CRIPTION . NUMBER. NUMBER ACTIVIT ENTR. CODE. REM . HOURS TA .RB SUPPORT ACTIVITY 6 CN 1.167 11.25. BAG TOOLS & TRASH / REM 3VE FROM RB 820917 004720 C20H001 820917 004721 C30C001 RB DECON-305' ELEV 4 CN 0.720 5.83 EQUIPMENT PROTECTION - 305' LEVEL 820917 004722 C20H001 RB SUPPORT ACTIVITY 1 CN 0.197 1.00 TRASH & TOOL REMOVAL 820917 004729 C30L001 DECON RB DOME 2 CM 0.304 4.00 DECON RB DOME FROM POLAR CRANE

  • 320917 004729 C30L001 DECON RB DOME 1 OP 0.142 2.08 DECON RB DOME FROM POLAR CRANE
  • 820917 004729 C30L001 DECON RB DOME 2 UM 0.263 4.37 DECON RB DOME FROM POLAR CRANE
  • S20917 004729 C30L001 DECON RB DOME 4 CN 0.693 9.42 DECON RB COME FROM POLAR CRANE
  • 820917 004729 C30L001 DECON RB DOME 1 RP 0.119 2.20 DECON RB DOME FROM POLAR CRANE 820920 004740 C20H001 RB SUPPORT ACTIVITY 11 CN 0.005 20.42 OPERATE NLB PUMP

$820920 004740 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.33 OPER ATE NLB PUMP 820922 004750 C20H001 RB SUPPORT ACTIVITY 48 CN 0.057 128.07 RB ENTRY SUPPORT - ANTER0OM

  • 820922 004750 C20H001 RB SUrPORT ACTIVITY 31 HP 0.048 144.43 RB ENTRY SUPPORT - ANTEROOM
  • 820922 004750 C20H001 RB SUPPORT ACTIVITY 4 OP 0.010 4.50 RB ENTRY SUPPORT - ANTERDOM
  • 820922 004750 C20H001 RB SUPPORT ACTIVITY

! MM 0.000 0.83 RB ENTRY SUPPORT - ANTEROOM 820922 004751 C20H001 RB SUPPORT ACTIVITY 14 CN 0.156 28.63 RB ENTRY SUPPORT - AIRLOCK 820923 004771 C20H001 RB SUPPORT ACTIVITY 2 CN 0.181 1.24 INSTALL PLATFORM & RAMP AT AIRLOCK NO. 1 820924 004772 C20H001 RB SUPPORT ACTIVITY 1 CR 0.130 0.78 MISC. TOOL. SAMPLE & TRASH REMOVAL 820926 004783 C30L001 DECON RB DOME 4 RP 0.504 7.82 DECON RB DOME FROM POLAR CRANE 820927 004792 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 20.33 OPERATE NLB PUMP 820928 004801 C20H001 RB SUPPORT ACTIVITY 1 HP 0.125 0.78 RAD SURVEY & HP COVERAGE - RB 'D' RING ,ca 820929 004803 C90K001 RB DATA ACQUISITION 2 HP 0.689 4.23 TV SURVEY OF 28?' ELEV. On *820929 004803 C90K001 RB DATA ACQUISITION 4 IC 0.616 7.47 TV SURVEY OF 282* ELEV e

  • 820929 004803 C90K001 RB DATA ACQUISITION 1 CN 0.325 2.02 TV SURVEY OF 282' ELEV.

820929 004804 C30A001 DECON POLAR CRANE 24 RP 2.800 49.26 LOW PRESSURE FLUSH OF POLAR CRANE

  • 820929 004804 C30A001 DECON POLAR CRANE 6 CN 0.846 14.38 LOW PRESSURE FLUSH OF POLAR CRANE
  • 820929 004804 C30A001 DECON POLAR CRANE 1 HP 0.118 2.23 LOW PRESSURE FLUSH OF POLAR CRANE 821001 004825 C20H001 RB SUPPORT ACTIVITY 1 HP 0.239 1.08 RAD SURVEY & HP COVERAGE - RB 821001 004826 C30A001 DECON POLAR CRANE 2 RP 0.202 2.00 TRASH REMOVAL 821001 004829 C20H001 RB SUPPORT ACTIVITY 11 CN O 095 23.96 RB ENTRY SUPPORT - AIRLOCK
  • 821001 004829 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 2.17 RB ENTRY SUPPORT - AIRLOCK
  • 821001 004829 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.25 RB ENTRY SUPPORT - AIRLOCK 821001 004830 C20H001 RB SUPPORT ACTIVITY 37 CN 0.097 94.54 RB ENTRY SUPPORT - ANTERPOM
  • 821001 004830 C20H001 RB SUPPORT ACTIVITY 23 HP 0.024 125.13 RB ENTRY SUPPORT - ANTEROOM
  • S21001 004830 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.88 RB ENTRY SUPPORT - ANTEROOM 821004 004838 C20H001 RB SUPPORT ACTIVITY 1 HP 0.066 0.83 RADIATION SURVEY & HP COVERAGE 821004 004841 C20H001 RB SUPPORT ACTIVITY 7 CN 0.000 21.60 OPERATE NLB PUMP /PE RTORM MAINT 821005 004858 C45H001 RB CORRECTIVE MAINT 3 IC 0.459 6.58 REPAIR TV EOUIPMENT
  • 821005 004858 C45H001 RB CORRECTIVE MAINT 1 RP 0.168 2.07 REPAIR TV EQUIPMENT 821006 004856 C30C001 RB DECON-305' ELEV 13 CN 1.447 20.48 REMOTE DECON & TOOL INVENTORY 821006 004859 C20H001 RB SUPPORT ACTIVITY 1 HP 0.075 0.93 RADIATION SURVEY /HP COVERAGE 821007 004866 C20H001 RB SUPPORT ACTIVITY 2 RP 0.270 2.50 TRASH AND TOOL REMOVAL 821007 004867 C20H001 RB SUPPORT ACTIVITY 1 HP 0.101 1.58 RADIATION SURVEY & HP COVER AGE 821008 004865 C30A001 DECON POLAR CRANE 12 CN 1.518 26.63 POLAR CRANE DECON - GENERAL
  • S21008 004865 C30A001 DECON POLAR CRANE 12 RP 1.244 26.32 POLAR CRANE DECON - GENERAL
  • 821008 004865 C30A001 DECON POLAR CRANE 7 HP 0.773 15.90 POLAR CRANE DECON - GENERAL 821008 004869 C20H001 RB SUPPORT ACTIVITY 64 CN 0.055 189.36 RB ENTRY SUPPORT - ANTEROOM
  • 821008 004869 C20H001 RB SUPPORT ACTIVITY 43 HP 0.072 237.53 RB ENTRY SUPPORT - AN TE R OOM
  • 321008 004869 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.47 RB ENTRY SUPPORT - ANTEROOM
  • 821008 004869 C20H001 RB SUPPORT ACTIVITY I SE 0.000 0.37 RB ENTRY SUPPORT - ANTERDOM 821008 004870 C20H001 RB SUPPORT ACTIVITY 20 CN 0.412 46.08 RB ENTRY SUPPORT - AIRLOCK

I DATE 052286 PAGE 21 PNO 20 RIO 24 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR DUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME TASK ................D E S. C R I P. T I O N.......................... ......... T..I V I T Y..................E.N T R..... CODE... REM....... HOURS

  • D. ATE.. NUMBER.NUMBE.R....

AC 821011 004881 C20H001 RB SUPPORT ACTIVITY 1 HP 0.035 0.48 RADIATION SURVL/ AND HP COVERAGE 821011 004883 C20H001 RB SUPPORT ACTIVITY 13 CN 0.000 44,30 OPERATE NLB PUMP /PE RF ORM MAINT.

  • 321011 004883 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 1.73 OPERATE NLB PUMP / PERFORM MAINT.
  • 821011 004883 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.95 OPERATE NLB PUMP / PERFORM MAINT.

821013 004895 C30L001 DECON RB DOME 9 CN 0.784 18.15 DECON RB DOME FROM POLAR CRANE 821014 004905 C20H001 RB SUPPORT ACTIVITY ! HP 0.045 0.65 RADIATION SURVEY AND HP COVERAGE 821014 004906 C30D001 RB DECON-282' ELEV 5 CN 0.422 10.83 REMOTE DECON - 282* LEVEL 821015 004914 C20H001 RB SUPPORT ACTIVITY 1 RP 0.125 2.03 TOOL AND TRASH REMOVAL

  • 821015 004914 C20H001 RB SUPPORT ACTIVITY 1 UM 0.128 2.05 TOOL AND TRASH REMOVAL 821015 004915 C90K001 RB DATA ACQUISITION 2 HP 0.461 4.77 TV SURVEY OF 282' ELEV
  • 821015 004915 C90K001 RB DATA ACQUISITION 4 CN 1.347 2.40 TV SURVEY OF 282* ELEV.

821015 004916 C30A001 DECON POLAR CRANE 25 CN 3.072 55.95 POLAR CRANE DECON - GENERAL

  • 821015 004916 C30A001 DECON POLAR CRANE 3 RP 0.314 6.48 POLAR CRANE DECON - GENERAL
  • 821015 004916 C30A001 DECON POLAR CRANE 9 HP 1.135 22.12 POLAR CRANE DECON - GENERAL 4821015 004916 C30A001 DECON POLAR CRANE 1 EL 0.108 2.40 POLAR CRANE DEu0N - GENERAL
  • 821015 004916 C30A001 DECON POLAR CRANE 2 MM 0.224 4.12 POLAR CRANE DECON - GENERAL 821015 004928 C20H001 RB SUPPORT ACTIVITY 48 CN 0.019 112.26 RB ENTRY SUPPORT - ANTERDOM
  • 821015 004928 C2SH001 RB SUPPORT ACTIVITf 26 HP 0.005 145.27 RB ENTRY SUPPORT - ANTER0OM
  • 821015 004928 C20H001 RB SUPPORT ACTIVITY 2 OP 0.003 1.71 RB ENTRY SUPPORT - ANTER0OM 821015 004929 C20H001 RB SUPPCRT ACTIVITY 13 CN 0.196 27.78 RB ENTRY SUPPORT - AIRLOCK 821015 004931 C30L001 DECON RB DOME 8 CN 0.984 13.58 POLAR CRANE PROTECTION
  • 821015 004931 C30L001 DECON RB DOME 2 RP 0.196 2.75 POLAR CRANE PROTECTION 821018 004930 C20H001 RB SUPPORT ACTIVITY 4 CN 1.395 9.28 LIFT RIG INSTALLATION 8

821018 004932 C20H001 RB SUPPORT ACTIVITY 4 CN 0.784 9.27 MODIFY LIFT RIG 00 821018 004934 C20H001 RB SUPPORT ACTIVITY 1 HP 0.085 0.75 RADIATION SURVEY AND HP COVERAGE Cn 821018 004937 C20H001 RB SUPPORT ACTIVITY 17 CN 0.000 66.25 OPERATE NLB PUMP / PERFORM MAINT.

  • 821018 004937 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 6.15 OPERATE NLB PUMP / PERFORM MAINT.
  • 821018 004937 C2CH001 RB SUPPORT ACTIVITY 2 OP 0.003 2.58 OPERATE NLB PUMP / PERFORM MAINT.
  • 821018 004937 C20H001 RB SUPPORT ACTIVITY 2 CM 0.000 0.25 OPERATE NLB PUMP / PERFORM MAINT.

821020 004942 C20H001 RB SUPPORT ACTIVITY 1 RP 0.120 1.43 TRASH AND TOOL REMOVAL

  • 821020 004942 C20H001 RB SUPP09T ACTIVITY 1 UM 0.120 1.67 TRASH AND TOOL REMOVAL 821020 004944 C20H001 RB SUPPORT ACTIVITY 2 CN 0.339 3.37 MODIF Y L I F T RIG 821020 004945 C30J001 RB DECON-347' ELEV 4 CN 0.318 4.55 E QUI PME N T PROTECTION - 347' LEVEL 821021 004949 C20H001 RB SUPPORT ACVIVITY 1 HP 0.094 2.08 RADIATION SURVEY /HP COVERAGE 821024 004968 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.03 OPERATE FS-V-639 821025 004969 C30D001 RB DECON-282* ELEV 1 HP 0.073 0.55 RADIATION SURVEY /TLD PLACEMENT 821025 004970 C20H001 RB SUPPORT ACTIVITY 14 CN 0.149 26.47 RB ENTRY SUPPORT - AIRLOCK
  • 821025 004970 C20H001 RB SUPPORT ACTIVITY 1 OP 0.004 0.48 RB ENTRY SUPPORT - AIRLOCK 821025 004971 C20H001 RB SUPPORT ACTIVITY 53 CN 0.088 143.13 RB ENTRY SUPPORT - ANTER0OM
  • 821025 004971 C20H001 RB SUPPORT ACTIVITY 24 HP 0.010 127.62 RB ENTRY SUPPORT - ANTEROOM 821025 004972 C20H001 RB SUPPORT ACTIVITY 9 CN 0.000 51.42 OPERATE AND MAINTAIN NLB PUMP
  • 821025 004972 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 5.58 OPERATE AND MAINTAIN NLB PUMP
  • 821025 004972 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 3.12 OPEkATE AND MAINTAIN NL8 PUMP 821025 004989 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 0.75 OPERATE FS-V-639
  • 821025 004989 C20H001 RB SUPPORT ACTIVITY

! HP 0.015 2.13 OPERATE FS-V-639 821027 004991 C30D001 RB DECON-282* ELEV 5 CN 0.256 9.22 REMOTE FLUSH - 282' LEVEL 821028 004997 C20H001 RB SUPPORT ACTIVITY 2 HP 0.046 1.57 RADIATION SURVEY /HP COVERAGE 821028 004998 C30A001 DECON POLAR CRANE 3 CN 0.998 11.75 POLAR CRANE DECON - GENERAL

  • 821028 004998 C30A001 DECON POLAR CRANE 1 RP 0.240 4.07 POLAR CRANE DECON - GENERAL 821029 005018 C20H001 RB SUPPORT ACTIVITY 13 CN 0.176 29.60 RB ENTRY SUPPORT - AIRLOCK

DATE 022486 PAGE 22 PNO 21 .TMI-2 UNC: t)S - ACTIVITY REPORT-REACTOR DUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TR?K. PERS. DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER ACTIVITY ENTR. CODE. REM

. HOURS ...............IPTION TASK DESCR

  • 821029 005018 C20H001 RB SUPPCRT ACTIVITY I OP 0.000 0.50 RB ENTRY SUPPORT - AIRLOCK 821029 005019 C20H001 RB SUPPORT ACTIVITY 30 CN 0.051 71.15 RB ENTRY SUPPORT - ANTEROOM 8821029 005019 C20H001 RB SUPPORT ACTIVITY 18 HP 0.018 109.88 RB ENTRY SUPPORT - ANTERDOM
  • 821029 005019 C20H001 RB SUPPORT ACTIVITY 2 RP 0.013 3.35 RB ENTRY SUPPORT - ANTE ROOM
  • 821029 005019 C20H001 RB SUPPORT ACTIVITY 1 IC 0.002 0.63 RB ENTRY SUPPORT - ANTEROOM
  • S21029 005019 C20H001 18 SUPPORT ACTIVITY

! OP 0.000 0.12 RB ENTRY SUPPORT - ANTEROOM 821101 005010 C20H001 18 SUPPORT ACTIVITY 1 HP 0.049 0.25 RADIATION SURVEY /HP COVERAGE 821101 005011 C20H001 iS SUPPORT ACTIVITY 2 RP 0.115 3.12 TRASH AND TOOL REMOVAL 821101 005025 C20H001 03 SUPPORT ACTIVITY 4 CN 0.000 16.73 DECON & MAINTENANCE - NLB PUMP $821101 005025 C20H001 R3 SUPPORT ACTIVITY 1 OP 0.000 2.60 DECON & MAINTENANCE - NLB PUMP 821103 005035 C30D001 Rt: DECON-282' ELEV 3 CN 0.219 6.58 REMOTE DECON - 282' LEVEL 821105 005046 C20H001 RL SUPPORT ACTIVITY 1 CN 0.166 1.82 RAD SURVEY / JOB COVERAGE / TRASH REMOVAL 821105 005050 C30A001 DE ':0 N POLAR CRANE 3 CN 0.347 6.15 REMOVE EQUIPMENT PROTECTION 821105 005051 C30J001 R8 DECON-347' ELEV 18 RP 3.020 42.60 DECON 341* LEVEL 821108 005057 C20H001 RB SUPPORT ACTIVITY 11 CN 0.178 25.70 RB ENTRY SUPPORT - AIRLOCK 821108 005058 C20H001 RB SUPPORT ACTIVITY 28 CN 0.050 58.54 RB ENTRY SbPPORT - ANTEROOM

  • S21108 005058 C20H001 R8 LUPPORT ACTIVITY 24 HP 0.010 126.48 RB ENTRY SUPPORT - ANTERDOM
  • 821108 005058 C20H001 R8 SUPPORT ACTIVITY 4 OP 0.000 3.38 RB ENTRY SUPPORT - ANTEROOM 821108 005059 C20H001 RB S1PPORT ACTIVITY 1 HP 0.125 1.05 RADIATION SURVEY /HP COVERAGE I

821108 005071 C20H001 RB SL'PPORT ACTIVITY 4 CN 0.000 13.10 OPE R ATE- & MAINT AIN NLB PUMP 00 821109 005077 C90K001 RB DATA ACQUISITION 1 CN 0.000 1.25 INSTALL SAMPLE PROBE '4 821110 005079 C20H001 RB SU? PORT ACTIVITY 1 HP 0.148 1,65 RAD SURVEY /RCS GAS SAMPLE / TRASH REMOVAL 8 *821110 005079 C20H001 RB SUPPORT ACTIVITY 1 OP 0.156 1.40 RAD SURVEY /RCS GAS SAMPLE / TRASH REMOVAL 821112 005089 C20H001 R8 SUFPORT ACTIVITY 4 HP 1.179 12.35 RAD SURVEY /HP COVERAGE / TRASH REMOVAL 821112 005090 C20H002 RB - COTV 2 IC 0.395 4.85 REPAIR CCTV'S-ELEV 305', 347' & P.C. 821112 005091 C30J001 R8 DECCN-347 'ELEV 4 RP 0.329 7.45 DECON 347' LEVEL 821112 005093 C20H001 R8 SUPF1RT ACTIVITY 2 CN 0.183 3.05 INSTALL ELECTRIC WINCHES ON LIFT RIGS 821114 005100 C20H001 RB SUPP7RT ACTIVITY 36 CN 0.028 84.03 RB ENTRY SUPPORT - ANTEROOM

  • 821114 005100 C20H001 RB SUPP.RT ACTIVITY 31 HP 0.041 173.82 RB ENTRY SUPPORT - ANTEROOM
  • 821114 005100 C20H001 RB SUPPCiT ACTIVITY 1 OP 0,000 1.32 RB ENTRY SUPPORT - ANTEROOM 821114 005101 C20H001 R8 SUPP0ti ACTIVITY 17 CN 0.316 39.30 RP ENTRY SUPPORT - AIRLOCK 821115 005102 C30D001 RB DECON-282' ELEV 3 CN 0.205 4.75 REMOTE DECON - 282* LEVEL 821115 005103 C30J001 R8 DECON-347' ELEV 15 RP 1.829 28.75 DECON 347* LEVEL 821115 005107 C20H001 R8 SUPPORT ACTIVITY 1 HP 0.176 2.25 RAD SURVEY /HP COVERAGE / TRASH REMOVAL 821115 005118 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 24.18 OPERATION & MAINT OF NLB PUMP 821115 005123 C45H001 RB CORREC1IVE MAINT 4 CN 0.002 8.16 MODIFY PENEYRATION 561
  • S21115 005123 C45H001 RB CORRECTIVE MAINT 2 QA 0.000 3.78 MODIFY PE NE TRATION 561
  • 821115 005123 C45H001 RB CORRECT!VE MAINT 1 HP 0.000 1.07 MODIF Y PENETRATION 561 821118 005130 C20H001 R8 SUPPORT ACTIVITY 4 HP 0.445 5.20 RAD SURVEY /HP COVERAGE /TR ASH REMOVAL 821118 005132 C20H001 RB SUPPORT ACTIVITY 4 CN 0.812 7.87 INSULATE ELECTRIC WINCHES - LIFT RIGS 821118 005134 C20H001 RB SUPPORT ACTIVITY 2 CN 0.440 3.42 ADD RECEPTACLES TO POWER BUGGIES 821119 005143 C30J001 RB DECON-347' ELEV 3 HP 0.455 6.33 DECON 347' LEVEL & ENCLOSED STAIRWELL
  • 821119 005143 C30J001 RB DECON-347' ELEV 10 RP 1.484 19.90 DECON 347' LEVEL & ENCLOSED STAIRWELL
  • 821119 005143 C30J001 RB DECON-347' ELEV 1 CN 0.000 4.27 DECON 347' LEVEL & ENCLOSED STAIRWELL 821122 005158 C20H001 RB SUPPORT ACTIVITY 10 CN 0.066 19.86 RB ENTRY SUPPORT - ANTEROOM
  • 821122 005158 C20H001 RB SUPPORT ACTIVITY 8 HP 0.010 33.42 RB ENTRY SUPPORT - ANTEROOM 821122 005162 C20H001 RB SUPPORT ACi!VITY 2 CN 0.000 8,13 OPERATE NLB PUMP 821124 005178 C20H001 RB SUPPORT ACTIVITY 26 CN 0.102 56.55 RB ENTRY SUPPORT - AIRLOCKS
  • 821124 005178 C20H001 RB SUPPORT ACTIVITY 27 HP 0.020 130.07 RB ENTRY SUPPORT - AIRLOCKS
  • 821124 005178 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 0.57 RB ENTRY SUPPORT - AIRLOCKS a

DATE 022486 PAGE 23 PNO. 22 .iMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS _ DEPT. EXPOS. TIME ........... TASK DESCRIPTION . HOURS ... E. N T R..... COD E.... R E M ACTIVITY

  • DATE... NUMBER. NUMBER......................................
  • 821124 005178 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.63 RB ENTRY SUPPORT - AIRLOCKS 821124 005179 C20H001 RB SUPPORT ACTIVITY 11 CN 0.254 26.26 RB ENTRY SUPPORT - AIRLOCK
  • 821124 005179 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.02 RB ENTRY SUPPORT - AIRLOCK 821124 005184 C20H001 RB SUPPORT ACTIVITY 1 CN 0.150 0.88 R ADI AT ION SURVE YS
  • 821124 005184 C20H001 RB SUPPORT ACTIVI TY I HP 0.105 1.02 RADIAi!ON SURVEYS 821124 005185 C20H001 RB SUPPORT ACTIVITV 2 RP 0.407 4.30 (NO TASK DESCRIPTION) 821124 005186 C50H001 RB P.M.

AND SURVEY 1 HP 0.015 2.38 INSTALL RB EXHAUST SAMPLING SYSTEM

  • 821124 005188 C50H001 RB P.M.

AND SURVEY 6 CN 0.013 8.02 INSTALL R3 EXHAUST SAMPLING SYSTEM S21128 005206 C20H001 RB SUPPORT ACTIVITY 4 CN O 000 30.07 OPERATION & MAINT OF NLB PUMP

  • S21128 005206 C20H001 RB SUPPORT ACTIVITY I HP 0.000 0.63 OPERATION & MAINT OF NLB PUMP 821129 005194 C20H001 RB SUPPORT ACTIVITY 1 HP 0.108 2.27 RADIATION SURVEY /HP COVERAGE 821129 005195 C20H001 RB SUPPORT ACTIVITY 2 CN 0.371 3.70 TRASH AND TOOL PEMOVAL 821129 005196 C30J001 RB DECON-347' ELEV 6 HP 1.072 14.48 DECON 347' LEVEL
  • 821129 005196 C30J001 RB DECON-347' ELEV 26 CN 4.059 53.10 DECON 347' LEVEL 82'201 005216 C20H001 RB SUPPORT ACTIVITY I HP 0.105 1.15 RADIATION SURVEY FOR TRASH REMOVAL 821201 005227 C20H002 RB - CCTV 1 UM 0.068 1.32 CCTV CAPERA I NVE N T OR Y
  • 321201 005217 C20H002 RB - CCTV 1 IC 0 244 1.83 CCTV CAMERA INVENTORY 821202 005227 C20H001 RB SUPPORT ACTIVITY 16 CN 0.254 32.23 RB ENTRY SUPPORT - AIRLOCK
  • 821202 005227 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 7.45 RB ENTRY SUPPORT - AIRLOCK 821202 005228 C20H001 RB SUPPORT ACTIVITY 41 CN 0.002 85.25 RB ENTRY SUPPORT - ANTEROOM 8 *821202 005228 C20H001 RB SUPPORT ACTIVITY 33 HP 0.012 180.08 RB ENTRY SUPPORT - ANTER0OM Cd *821202 005228 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.70 RB ENTRY SUPPORT - ANTEROOM 00 821202 005236 C30J001 RB DECON-347' ELEV 1 HP 0.160 2.15 DECON 347' LEVEL / REMOTE DECON 282' LEVEL
  • S21202 005236 C30J001 RB DECON-347' ELEV 13 CN 1.718 22.38 DECON 347' LEVEL / REMOTE DECON 282' LEVEL 821202 005237 C30J001 RB DECON-347' ELEV 2 CN 0 152 2.00 OPEN ELEVATOR DOOR - 305* & 347* LEVELS 821203 005234 C20H003 RB RADIO SYSTEM 2 CN 0.220 3.22 MOTOROLA RADIO BASE STATION OPERATION 821206 005248 C20H001 RB SUPPORT ACTIVITY 1 HP O 060 0.82 RADIATION SURVEw FOR TRASH REMOVAL 821206 005251 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 23 50 OPERATION AND MAINT OF NLB PUMP
  • 821206 005251 C20H001 RB SUPPORT ACTIVITY 2 OP 0.005 0.67 OPERATION AND MAINT OF NLB PUMP 821208 005268 C20H002 RB - CCTV 2 IC 0.000 0.97 REPAIRS IN PENETPATION 507 & CCTB-1 821208 005269 C20H001 RB SUPPORT ACTIVITY 3 CN 0.495 6.50 REMOTE DECON OF 282' LEVEL 821208 005280 C20H001 RB SUPPORT ACTIVITY 15 CN 0.223 32.90 RB ENTRY SUPPORT - AIRLOCK 821208 005281 C20H001 RB SUPPORT ACTIVITY 44 CN 0.098 89.14 RB ENTRY SUPPORT - ANTEROOM
  • 821208 005281 C20H001 RB SUPPORT ACTIVITY 37 HP 0.045 208.55 RB ENTRY SUPPORT - ANTEROOM
  • 821208 005281 C20H001 RB SUPPORT ACTIVITY 3 SE 0.000 2.00 RB ENTRY SUPPORT - ANTEROOM
  • 821208 005281 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 1.03 RB ENTRY SUPPORT - ANTEROOM
  • 821208 005281 C20H001 RB SUPPORi ACTIVITY 1 OP 0.000 0.63 RB ENTRY SUPPORT - ANTER0OM 821209 005282 C30C001 RB DECON-305' ELEV 4 OP 0.603 6.02 DECON 305' LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' ELEV 2 HP 0.220 2.83 DECON 305' LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' E LEV 4 CM' O.464 6.53 DECON 305' LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' ELEV 3 UM 0.137 3.27 DECON 305' LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' ELEV 1 MM 0.100 1.80 DECON 305' LEVEL TO 347' L EVE L
  • 821209 005282 C30C001 RB DECOM-305* ELEV 1 IC 0.193 1.75 DECON 305' LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' ELEV 2 RP 0.380 2.77 DECON 305* LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' ELEV 2 CN 0.220 2.17 DECON 305" LEVEL TO 347' LEVEL 821210 005296 C20H002 RB - CCTV 2 IC 0.545 3.78 REPAIRS IN PENETRATION 507 & CCTB-1 821210 005298 C90K001 RB DATA ACQUISITION 5 CN 1.019 9.73 TEMP LIGHTS-305'/TV SURVEY OF CA-V-48 821213 005303 C90K001 RB DATA ACQUISITION 2 CN 0.105 1.52 TV SURVEY - 305' ELEV / EQUIPMENT REMOVAL 821213 005304 C30D001 RB DECON-282' ELEV 5 CN 0.411 8.62 REMOTE DECON - 282* LEVEL 821213 005305 C30J001 RB DECON-347' ELEV 1 HP 0.147 2.07 DECON 347' LEVEL j

l

DATE 022486 PAGE 24 PNO. 23 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER ACTIVITY ENTR

. CODE TASK DESCRIPTION s......,....... NUMBER ........ REM........ HOURS

  • 821213 005305 C30J001 RB DECON-347' ELEV 1 EL 0.127 2.00 DECON 347' LEVEL
  • 821213 005305 C30J001 RB DECON-347' ELEV 1 CM 0.159 2.00 DECON 347' LEVEL
  • 821213 005305 C30J001 RB DECON-347' ELEV 1 BS 0.110 2.10 DECON 347' LEVEL
  • 821213 005305 C30J001 RB DECON-347' ELEV 1 IC 0.137 2.15 DECON 347* LEVEL 821214 005319 C30C001 RB DECON-305' ELEV 1 RP 0.244 1.30 DECON 305* LEVEL TO 347' LEVEL
  • 821214 005319 C30C001 RB DECON-305' ELEV 1 MM 0.212 1.49 DECON 305' LEVEL TO 347' LEVEL
  • 821214 005319 C30C001 RB DECON-305' ELEV 2 CM 0,404 2.75 DECON 305' LEVEL TO 347' LEVEL 821214 005321 C20H002 RB - CCTV 3 CN 0.631 7.67 LAYOUT AREA TO ACCEPT GANTRY 821216 005337 C20H001 RB SUPPORT ACTIVITY 18 CN 0.283 40.34 RB ENTRY SUPPORT - AIRLOCK
  • 821216 005337 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 0.68 RB ENTRY SUPPORT - AIRLOCK 821216 005341 C30D001 RB DECON-282* ELEV 4 CM 0.244 5.47 REMOTE DECON - 282' LEVEL 821216 005342 C30J001 RB DECON-347' ELEV 1 CM 0.044 0.73 DECON 347' LEVEL
  • 821216 005342 C30J001 RB DECON-347' ELEV 1 OP 0.048 0.77 DECON 347' LEVEL 821217 005350 C50H001 RB P.M.

AND SURVEY 2 OP 0.361 2.60 SMOKE DETECTORS FUNCTIONAL TEST 821217 005351 C20H001 RB SUPPORT ACTIVITY 2 HP 0.383 2.90 RADIATION SURVEY - NEUT SHIELD TANKS 821217 005356 C20H001 RB SUPPORT ACTIVITY 8 DP 0.000 17.50 TRANSFER WATER - PWST-2 & BWST

  • 821217 005356 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 4.52 TR ANSF ER WAT ER - PWST-2 & BWST 821219 003088 C50H001 RB P.M.

AND SURVEY 2 MM 0.050 2.33 REMOVE SHAFT COUP COV PLATE / ROTATE PUMP

  • 821219 003088 C50H001 RB P.M.

AND SURVEY I OP 0.015 1.50 REMOVE SHATT COUP COV PLATE / ROTATE PUMP

  • 821219 003088 C50H001 RB P.M.

AND SURVEY 1 CN 0.070 2.50 REMOVE SHAFT COUP COV PLATE /ROIATE PUMP 8 821220 005360 C20H001 RB SUPPORT ACTIVITY 1 EL 0.083 1.25 TOOL AND EQUIPME NT REMOVAL W *821220 005360 C20H001 RB SUPPORT ACTIVITY 1 RP 0.061 .47 T001 AND EQUIPMENT REMOVAL 8212:0 005376 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 16.92 OPERATION AND M% INT OF NLB PUMP 821221 005381 C20H004 RB SPIDER 2 CN 0.224 2.76 GENERAL MAINT - P C. TROLLEY SPIDER 821222 005386 C20H001 RB SUPPORT ACTIVITY 1 HP 0.058 0.77 RADIATION SURVEY - SERVICE STRUCTUSE 821222 005387 C30D001 RB DECON-282' ELEV 1 EL 0.056 2.22 REMOTE DECON - 282' & 347' ELEVTR SHAFT

  • 821222 005387 C30D001 RB DECON-282* ELEV 3 CM 0.244 4.64 REMOTE DECON-- 282' & 347' ELEVTR SHAFT
  • 821222 005387 C30D001 RB DECON-282' ELEV 1 UM 0.212 1.97 REMOTE DECON - 282* & 347' ELEVTP SHAFT 821222 005388 C90K001 RB DATA ACQUISITION 3 CN 0.334 4.48 REMOVE CRD CABLE SAMPLES 821223 005391 C20H001 RB SUPPORT ACTIVITY 32 CN 0.024 51.08 RB ENTRY SUPPORT - ANTER0OM
  • 821223 005391 C20H001 RB SUPPORT ACTIVITY 22 HP 0.025 111.33 RB ENTRY SUPPORT - ANTEROOM
  • 821223 005391 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 0.42 RB ENTRY SUPPORT - ANTEROOM
  • 821223 005391 C20H001 RB SUPPORT AC1IVITY I OP 0.000 0.95 RB ENTRY SUPPORT - ANTEROOM 821223 005392 C20H001 RB SUPPORT ACTIVITY 9 CN 0.155 46.72 RB ENTRY SUPPORT - AIRLOCK 821223 005393 C30C001 RB DECON-305' ELEV 3 CN 0.383 5.83 INSTALL WATER DIST. HEADER & PUMP 821223 005395 C35N002 DOSE REDUCTION-347' 2 OP 0.172 3.20 RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS
  • 821223 005395 C35N002 DOSE REDUCTION-347' 1 IC 0.123 1,43 RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS
  • 821223 005395 C35N002 DOSE REDUCTION-347' 1 HP 0.186 2.17 RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS
  • 821223 005395 C35N002 DOSE REDUCTION-347' 1 CN 0.110 1.55 RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS 821227 005409 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 24.07 OPERATION AND MAINT OF NLB PUMP 821228 005421 C30D001 RB DECON-282' ELEV 1 EL 0.053 1.77 REMOTE DECON OF 282* LEVEL
  • 821228 005421 C30D001 RB DECON-282' ELEV 1 CM 0.032 2.22 REMOTE DECON OF 282* LEVEL S21228 005422 C70H001 RB RAD SURVEYS 1 HP 0.161 1.08 HP SURVE Y/ JOB COVER AGE / TRASH REMOVAL 821229 005427 C30D001 RB DECON-282' ELEV 2 CM 0.179 4.03 REMOTE DECON OF 282* LEVEL 821229 C05431 C20H001 RB SUPPORT ACTIVITY 1 HP 0.027 0.83 INVESTIGATE FIRE ALARM
  • 821229 005431 C20H001 RB SUPPORT ACTIVITY I OP 0.026 0.80 INVESTIGATE FIRE ALAPM 821230 005435 C20H001 RB SUPPCRT ACTIVITY 10 CN 0.138 21.28 RB ENTRY SUPPORT - AIRLOCK 821230 005436 C20H001 RB SUPPORT ACTIVITY 28 CN 0.000 57.60 RB ENTRY SUPPORT - ANTER0OM
  • S21230 005436 C20H001 RB SUPPORT ACTIVITY 29 HP 0.013 145.45 RB ENTRY SUPPORT - ANTEROCH
  • 821230 005436 C20H001 RB SUPPORT ACTIVITY 1 RP 0.008 1.12 RB ENIRY SUPPORT - ANTEROOM

. - ~. .___m.mm_.m _m _m ._m. -_m._ _ _ _ _ _ _ _.. -._ m -._ .. _ ~ ~. _ _. _. -. _ - _ _ -. -.._. ~ 4 l I i i i DATE 022486 PAGE 25 PNO. 24 1-

  • RWP.

.UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D .TMI-2 .RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME +

  • DA T E... NUMB.E.R. NUMBE.R........... C. T. I V I T Y................ENTR......... E... R E M..... H. O U R S...............

A . COD TASK DESCR 821230 005443 C30D001 RB DECON-282* ELEV 1 EL 0.024 1.70 REMOTE DECON OF 282' LEVEL $821230 005443 C300001 RB DECON-282* ELEV 1 CM 0.045 1.75 REMOTE DECON OF 282* LEVEL 830103 005465 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 23.68 OPERATION AND MAINT OF NLB PUMP i 830104 005457 C300001 RB DECON-282* ELEV 2 CN 0.185 4.80 REMOTE DECON OF 282' LEVEL 4 830104 005459 C20H001 RB SUPPORT ACTIVITY 3 CN 0.463 5.40 TRASH REMOVAL } 830104 005460 C20H001 RB SUPPORT ACTIVITY 2 RP 0.291 4.60 TOOL INVENTORY AND SORTING 830104 005463 C30M001 DECON SERVICE STRUCT 1 UM 0.204 1.47 PUMCH HOLES IN NEUTRON SHIELD TANKS 830105 005475 C30M001 DECON SERVICE STRUCT 1 HP 0.161 1.80 NEUTRON SHIELD TANK MODIFICATIONS

  • 830105 005475 C30M001 DECON SERVICE STRUCT 1 UM 0.247 1.75 NEUTRON SHIELD TANK MODIFICATIONS 830106 005488 C20H001 RB SUPPORT ACTIVITY 10 CN 0.105 21.20 RB ENTRY SUPPORT - AIRLOCK 830106 005489 C20H001 RB SUPPORT ACTIVITY 46 CN 0.033 93.42 RB ENTRY SUPPORT - ANTER0OM
  • 830106 005489 C20H001 RB SUPPORT ACTIVITY 53 HP 0.006 221.03 RB ENTRY SUPPORT - ANTERDOM i
  • 830106 005489 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 3.02 RB ENTRY SUPPORT - ANTERDOM 830106 005492 C30M001 DECON SERVICE STRUCT 15 CN 1.929 27.80 DECON HISSILE SHIELD 830107 005501 C90K001 RB DATA ACQUISITION 2 IC 0.241 3.37 REPAIR RB SUMP CAMERA' 830110 005507 C70H001. RB RAD SURVEYS 1 HP 0.106 1.42 HP SURVEY / JOB COVERAGE / TRASH REMOVAL 830110 005511 C30M001 DECON SERVICE STRUCT 6 OP 0.747 12.62 DECON MISSILE SHIELD & SERVICE STRUCTURE
  • 830110 005511 C30M001 DECON SERVICE STRUCT 1 IC 0.110 2.73 DECON MISSILE SHIELD & SERVICE STRUCTURE 830110 005522 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 33.50 OPERATION AND MAINT OF NLB PUMP 8

830110 005528 C45H001 RB CORRECTIVE MAINT 2 CN 0.267 3.08 TROUBLESHOOT CAMERA ELECTRICAL PROBLEM i Jh 830111 005532 C20H001 RB SUPPORT ACTIVITY 16 CN 0.194 34.67 RB ENTRY SUPPORT - AIRLOCK t C) 830111 005534 C70H001 RB RAD SURVEYS 1 HP 0.049 1.08 HP SURVEY / JOB COVERAGE / TRASH REMOVAL i l 830111 005537 C20H001 RB SUPPORT ACTIVITY 1 CN 0,000 0.93 MEASUREMENT FOR AIRLOCK FALSE FLOOR 1 830112 005544 C70H001 RB RAD SURVEYS 2 HP 0.079 0.98 HP SURVEY / JOB CIVERAGE/ TRASH REMOVAL 830112 005546 C80N001 RB WASTE REMOVAL 3 CN 0.010 3.95 TRASH REMOVAL - 305* LEVEL

  • 830112 005546 C80N001 RB WASTE REMOVAL 1 HP 0.002 1.17 TRASH REMOVAL - 305' LEVEL 1

830113 005554 C20H001.RB SUPPORT ACTIVITY 21-CN 0.023 35.16 RB ENTRY SUPPORT - ANTEROOM

  • 830113 005554 C20H001 RB SUPPORT ACTIVITY 19 HP 0.000 85.92 RB ENTRY SUPPORT - ANTER0OM 2830113 005554 C20H001 RB SUPPORT ACTIVITY 2 AD 0.000 0.20 RB ENTRY SUPPORT - ANTER0OM
  • 830113 005554 C20H001 RB SUPPORT ACTIVITY 1 VI 0.000 0.05 RB ENTRY SUPPORT - ANTER0OM 830113 005559 C30E001 DECON RB D RINGS 1 MM 0.543 1.70 PORV PROTECTION I
  • 830113 005559 C30E001 DECON RB D RINGS 1 RP 0.620 1.70 -

PORV PROTECTION $830113 0055 9 C30E001 DECON RB D RINGS 1 HP. 0.182 1.60 PORV PROTECTION 1 HP 0.160 1.35 HP SURVEY / JOB COVERAGE / TRASH REMOVAL 830114 005568 C70H001 RB RAD SURVEYS 2 CN 0.247 4,07 INSTALL PPOCESS WATER HEADER & PUMP 830114 005570 C30C001 RB DECON-305* ELEV 830117 005576 C45H001 RB CORRECTIVE MAINT 4 CN 0.927 7 30 PLUG SERVICE AIR TO ISOLATE 282* ELEV 830117 005579 C70H001 RB RAD SURVEYS 2 OP 0.250 4.83 FLUSH TOP OF HISSILE SHIELDS

  • 830117 005579 C70H001 RB RAD. SURVEYS 2 CM 0.254 4.55 FLUSH TOP OF MISSILE SHIELDS
  • 830117 005579 C70H001 RB RAD SURVEYS 1 CN 0.163 2.27 FLUSH TOP OF MISSILE SHIELDS

$830117 005579 C70H001 RB RAD SURVEYS 1 UM 0.090 1,67 FLUSH TOP OF MISSILE SHIELDS a 830117 005580 C20H001 RB SUPPORT ACTIVITY 3 CN 0.044 5.90 RB ENTRY SUPPORT - AIRLOCK 830117 005592 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 33.58 OPERATE AND MAINTAIN NLB PUMP 830117 005881 C20H001 RB SUPPORT ACTIVITY 41 CN 0.023 68.88 RB ENTRY SUPPORT - ANTEROOM i

  • 830117 005881 C20H001 RB SUPPORT ACTIVITY 32 HP 0.015 176.83 RB ENTRY SUPPORT - ANTEROOM i,
  • 830117 005881 C20H001 RB SUPPORT ACTIVITY-2 OP 0.000 1.67 RB ENTRY SUPPORT - ANTEROOM 830118 005604 C30J001 RB DECON-347' ELEV 2 OP 0.296 3.65 DECON ELEVATOR SHAFT & SERVICE STRUCTURE
  • 830118 005604 C30J001 RB DECON-347' ELEV 1 EL 0.154 2.55 -

DECON ELEVATOR SHAF T & SERVICE STRUCTURE

  • 830118 005604 C30J001 RB DECON-347' ELEV 1 CM 0.119 2.37 DECON ELEVATOR SHAFT & SERVICE STRUCTURE l

-*830118 005604 C30J001 RB DECON-347ELEV 1 MM 0.109 2.43 DECON ELEVATOR SHAFT & SERVICE STRUCTURE

  • 830118 005604 C30J001 RB DECON-347' ELEV 1 CN 0,163 2.28 DECON ELEVATOR SHAFT & SERVICE STRUCTURE i

I 1 i i i 1 a

l l l l DATE 022486 FAGE 26 PN0 25 .TMI-2 UNC: UDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER
  • ............. NUMBER....................IVITYACT.................

. 25.37. ......SK DESCRIP. TION ENTR. CODE. REM . HOURS TA 830118 005608 C20H001 RB SUPPORT' ACTIVITY. 12 CN 0.139 R8 ENTRY SUPPORT - AIRLOCK 830119 005616 C30J001 RB DECON-347' ELEV 2 OP 0.184 3.03 DECON ELEVATOR SHAFT & SERVICE STRUCTURE

  • 830119 005616 C30J001 RB DECON-347' ELEV 1 EL 0.330 2.03 DECON ELEVATOR SHAF T & SERVICE STRUCTURE
  • 830119 005616 C30J001 R8 DECON-347' ELEV 1 CH 0.110 1.65 DECON ELEVATOR SHAFT & SERVICE STRUCTURE
  • 830119 005616 C30J001 RB DECON-3A7' ELEV 1 MM 0.338 2.05 DECON ELEVATOR SHAFT & SERVICE STRUCTURL 830120 005620 C70H001 RB RAD SURVEYS 1 HP 0.136 0.93 HP SURVEY / JOB COVERAGE 830121 005628 C30E001 DECON R8 D RINGS 1 EL 0.124 1.80 DECON ELEVATOR, RVHSS &

'A' D RING $830121 005628 C30E001 DECON RB D RINGS 1 IC 0.207 1.75 DECON E LE VATOR, RVHSS & 'A' D RING

  • 830121 005628 C30E001 DECON RB D RINGS 1 UM 0.063 1.22 DECON ELEVATOR, RVHSS &

'A' D RING 830124 005637 C20H001 R8 SUPPORT ACTIVITY 22 CN 0.275 41.25 RB ENTRY SUPPORT - AIRLOCK 830124 005638 C20H001 RB SUPPORT ACTIVITY 54 CN 0.019 95.88 RB ENTRY SUPPORT - ANTEROOM

  • 830124 005638 C20H001 R8 SUPPORT ACTIVITY 40 HP 0.020 174.18 RB ENTRY SUPPORT - ANTEROOM
  • 830124 005638 C20H001 R8 SUPPORT ACTIVITY 2 OP 0.003 3.52 RB ENTRY SUPPORT - ANTER0OM 830124 005642 C30E001 DECON RB D RINGS 2 CM 0.305 4.08 REMOTE FLUSH OF MISSILE SHIELD
  • 830124 005642 C30E001 DECON RB D RINGS 1 EL 0.175 2.35 REMOTE FLUSH OF MISSILE SHIELD
  • 830124 005642 C30E001 DECON RB D RINGS 2 IC 0.174 3.47 REMOTE FLUSH OF MISSILE SHIELD
  • 830124 005642 C30E001 DECON RB D RINGS 1 UM 0.115 1.58 REMOTE FLUSH OF MISSILE SHIELD 830124 005651 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 11.22 DECON U-1 TO U-2 CORRIDOR 830127 005678 C35N003 DOSE REDUCTION-305' 4 RP 0.711 6.77 SHIELDING INSTALLATION
  • 830127 005678 C35N003 DOSE REDUCTION-305' 3 OP 0.819 6.33 SHIELDING INSTALLATION e *830127 005678 C35N003 DOSE REDUCTION-305' 1 EL 0.371 1.92 SHIELDING INSTALLATION
    • *830127 005678 C35N003 DOSE REDUCTION-305' 3 MM 0.925 6.10 SHIELDING INSTALLATION

-d

  • 830127 005678 C35N003 DOSE REDUCTION-305' 1 BS 0.065 1.20 SHIELDING INSTALLATION 8 *830127 005678 C35N003 DOSE REDUCTION-305' 2 IC 0.428 3.12 SHIELDING INSTALLATION
  • 830127 005678 C35N003 DOSE REDUCTION-305' 2 CN 0.468 3.20 SHIELDING INSTALLATION l

830128 005681 C20H002 RB - CCTV 1 UM 0.049 1.32 REPLACE PAN TILT UNIT ON CAMERA 6 l

  • 830128 005681 C20H002 R8 - CCTV 1 IC 0.046 1.33 REPLACE PAN TILT UNIT ON CAMERA 6 830131 005695 C20H001 RB SUPPORT ACTIVITY 59 CN 0.017 134.40 RB ENTRY SUPPORT - ANTEROOM
  • 830131 005695 C20H001 RB SUPPORT ACTIVITY 27 HP 0.015 145.25 RB ENTRY SUPPORT - ANTEROOM
  • 830131 005695 C20H001 R8 SUPPORT ACTIVITY 1 OP 0.003 5.33 RB ENTRY SUPPORT - ANTEROOM 830131 005696 C20H001 RB SUPPORT ACTIVITY 17 CN 0.183 28.95 RB ENTRY SUPPORT - AIRLOCK

$830131 005696 C20H001 R8 SUPPORT ACTIVITY 2 OP 0.000 0.83 R8 ENTRY SUPPORT - AIRLOCK 830131 005697 C20H001 RB SUPPORT ACTIVITY 20 CN 0.112 40.91 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK l

  • 830131 005697 C20H001 RB SUPPORT ACTIVITY 5 HP 0.000 12.80 R8 ENTRY SUPPORT - EQUIPMENT AIRLOCK l
  • 830131 005697 C20H001 RB SUPPORT ACTIVITY

! OP 0.000 0.92 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830131 005710 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 5.98 OPERATION & MAINTENANCE OF NLB PUMP 830201 005714 C35N003 DOSE REDUCTION-305* 5 CN 1.098 13.22 INSTALL SHIELDING SUPP/ INSTALL PLATFORM l 830201 005715 C35N005 DOSE REDUCTION-RVHSS 8 CN 1.688 13.87 REMOVE FANS l 3830201 005715 C35N005 DOSE REDUCTION-RVHSS 2 HP 0.382 3.82 REMOVE FANS 830202 005721 C35N003 DOSE REDUCTION-305' 2 CM 0.275 2.23 RE SIN COLUMN ELUTTON

  • 830202 005721 C35N003 DOSE REDUCTION-305' 1 HP 0.125 1.20 RESIN COLUMN ELUTION 830202 005723 C20H001 RB SUPPORT ACTIVITY 3 CN 0.254 4.83 RELOCATE SPIDER
  • 830202 005723 C20H001 RB SUPPORT ACTIVITY 1 EL 0.100 1.72 RELOCATE SPIDER 830203 005732 C35N003 DOSE REDUCTION-305' 5 CN 0.616 3.57 INSTALL SHIELDING SUPP IN OPEN STAIRWELL 830207 005755 C20H001 RB SUPPORT ACTIVITY 50 CN 0.059 98.41 RB ENTRY SUPPORT - ANTEROOM
  • 830207 005755 C20H001 RB SUPPORT ACTIVITY 42 HP 0.051 246.17 RB ENTRY SUPPORT - ANTERDOM
  • S30207 005755 C20H001 R8 SUPPORT ACTIVITY 3 OP 0.010 10.17 RB ENTRY SUPPORT - ANTERDOM
  • S30207 005755 C20H001 R8 SUPPORT ACTIVITY 2 RP 0.000 8.25 R8 ENTRY SUPPORT - ANTERDOM j

830207 005758 C30E001 DECON RB D RINGS 19 CN 3.154 37.68 REMOTE FLUSH - SERV. STRUCT. &

  • D' RING 830207 005759 C20H001 RB SUPPORT ACTIVITY 23 CN 0.288 42.42 RB ENTRY SUPPORT - PERSONNEL AIRLOCK l

l l i i

DATE 022486 PAGE 27 PNO. 26 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..E.N T R ............................ S.K DE.SC.R I P T ION . CODE. REM . HOURS. TA

  • D AT E.. NUMB E.R. NUMBE.R

........C. T I V I T. Y A 830207 005760 C20H001 RB SUPPORT ACTIVIT" 6 CN 0.028 10.29 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK

  • B30207 005760 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 1.78 RB ENTRY SUPPORT - EQUIPME NT AIRLOCK
  • 830207 005760 C20H001 RB SUPPORT ACTIVITY 1 MM 0.004 0.55 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830207 005767 C20H001 RB SUPPORT ACTIVITY 6 CN 0.003 34.48 OPER ATION AND MAINTE NANCE OF NLB PUMP
  • 830207 005767 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.87 OPERA 1!ON AND MAINTENANCE OF NLB PUMP
  • 830207 005767 C20H001 RB SUPPORT ACTIVITY 1 OP 0.002 0.37 OPE R ATION AND MAINTENANCE OF NLB PUMP 830208 005774 C35N003 DOSE REDUCTION-305' 2 CN 0.381 3.35 RESIN COLUMN ELUTION 830209 005782 C20H002 RB - CCTV 2 CN 0.204 3.46 INSTALL FEST00N CABLE FOR P.C. CAMERA
  • 830209 005782 C20H002 RB - CCTV 1 MM 0.105 1.87 INSTALL FEST00N CABLE FOR P.C. CAMERA 830210 005791 C20H001 RB SUPPORT ACTIVITY 3 RP 0.607 7 67 TRASH AND TOOL REMOVAL
  • 830210 005791 C20H001 RB SUPPORT ACTIVITY 1 BS 0.187 1.98 TRASH AND TOOL REMOVAL
  • 830210 005791 C20H001 RB SUPPORT ACTIVITY 1 HP 0.060 3.70 TRASH AND TOOL REMOVAL 830211 005798 C20H002 RB - CCTV 1 UM 0.239 3.31 MAINTENANCE ON P.C.

TV EQUIPMENT

  • 830211 005798 C20H002 RB - CCTV 1 IC 0.140 3.52 MAINTENANCE ON P.C.

TV EQUIPMENT

  • 830211 005798 C20H002 RB - CCTV 1 RP 0.163 3.58 MAINTENANCE ON PC. TV EQUIPMENT 830211 005803 C20H001 RB SUPPORT ACTIVITY 1 CN 0.002 0.33 INSTALL FITTING ON EMERGENCY AIR SUPPLY 830211 005805 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 11.50 DECON NLB PUMP ENCLOSURE 830214 005815 C20H001 RB SUPPORT ACTIVITY 3 CN 0.486 8.92 CLEAN POLAR CRANE 830214 005816 C20H001 RB SUPPORT ACTIVITY 21 CN 0.283 42.30 RB ENTRY SUPPORT - PERSONNEL AIRLOCK RB $UPPORT ACTIVITY 48 CN 0.034 92.61 RB ENTRE SUPPORT - AIRLOCK 1 **830214 005818 C20H001 830214 005818 C20H001 RB SUPPORT ACTIVITY 45 HP 0.069 240.12 RB ENTRY SUPPORT - AIRLOCK 830214 005818 C20H001 RB SUPPORT ACTIVITY 5 SE 0.000 3.87 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 2.75 RB ENTRY SUPPORT - AIRLOCK m
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 4 RP 0.025 9.83 RB ENTRY SUPPORT - AIRLOCK s
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 1.50 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACLIVITY 2 MM 0.000 1.70 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 3 CM 0.000 4.32 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 1 AM 0.000 0.20 RB ENTRY SUPDDRT - AIRLOCK 830214 005819 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 35.63 OPERATE AND MAINTAIN NLB PUMP 830215 005833 C20H001 RB SUPPORT ACTIVITY 1 EL 0.196 1.70 TRASH AND TOOL REMOVAL
  • 830215 005833 C20H001 RB SUPPORT ACTIVITY 1 OP 0.139 1.83 TRASH AND TOOL REMOVAL
  • 830215 005833 C20H001 RB SUPPORT ACTIVITY 1 CM 0.206 1.69 TRASH AND TOOL REMOVAL 830215 005836 C20H001 RB SUPPORT ACTIVITY 3 RP 0.444 5.72 REMOVE SERVICE STRUCTURE FANS
  • 830215 005836 C20H001 RB SUPPORT ACTIVITY 1 HP 0.115 1.95 REMOVE SERVICE STRUCTURE FANS 830215 005838 C20H002 RB - CCTV 1 IC 0.002 1.34 DECON SUt1P TV CAMERA 830215 005841 C80N001 RB WASTE REMOVAL 4 RP 0.093 10.91 PACM & TRANSPORT HI RAD TRASH FROM RB
  • 830215 005841 C80N001 RB WASTE REMOVAL 1 HP 0.028 2.05 PACK & TRANSPORT HI R AD TR ASH FROM RB
  • 830215 005841 C80N001 RB WASTE REMOVAL 2 CN 0.035 5.93 PACK & TRANSPORT HI RAD TRASH FROM RB
  • 830215 005841 C80N001 RB WASTE REMOVAL 1 CM 0.010 2.13 PACK & TRANSPORT HI RAD TRASH FROM RB 830217 005852 C30E001 DECON RB D RINGS 1 UM 0.083 1.42 REMOTE FLUSH OF

'D' RING / SORT TOOLS

  • 830217 005852 C30E001 DECON RB D RINGS 1 EL 0.247 2.57 REMOTE FLUSH OF

'D' RING / SORT TOOLS

  • 830217 005852 C30E001 DECON RB D RINGS 2 CM 0.301 4.03 REMOTE FLUSH OF

'D' RING / SORT TOOLS 830217 005855 C35N003 DOSE REDUCTION-305* 4 OP 0.690 7.05 E NCLOSE STAIRWE LL /SHIE LD ST AIRWE LL

  • 830217 005855 C35N003 DOSE REDUCTION-305*

1 UM 0.187 1.13 ENCLOSE STAIRWELL / SHIELD STAIRWELL

  • 830217 005855 C35N003 DOSE REDUCTION-305' 2 CN 0.335 2.60 ENCLOSE STAIRWELL / SHIELD STAIRWELL 830217 005856 C20H001 RB SUPPORT ACTIVITY 4 CN 0.502 9.53 PREPARE POLAR CRANE FOR TESTING 830218 005865 C20H001 RB SUPPORT ACTIVITY 1 CN 0.010 1.70 FUNCTIONAL CHECK OF EQUIP HATCH DOORS
  • 830218 005865 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 0.63 FUNCTIONAL CHECK OF EQUIP HATCH DOORS
  • 830218 005865 C20H001 RB SUPPCRT ACTIVITY 1 MD 0.008 2.60 FUNCTIONAL CHECK OF EQUIP HATCH DOORS
  • 830218 005865 C20H001 R3 SUPPORT ACTIVITY I IC 0.005 1.35 FUNCTIONAL CHECK OF EQUIP HATCH DOORS

DATE 022486 PAG' 28 PNO. 27 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE
  • ...... NUMBER. NUMBER....................IVITY.................,............. REM........ HOURS ACT ENTR. CODE TASK DE

...........SCRIPTION 830221 005892 C20H001 RB SUPPOR T ACTIVITY. 6 CN 0.000 27.12 OPERATE AND MAINTAIN NLB PUMP 830222 005874 C20H001 RB SUPPORT ACTIVITY 38 CN 0.023 57.46 RB ENTRY SUPPORT

  • S30222 005874 C20H001 RB SUPPORT ACTIVITY 28 HP 0.014 131.83 RB ENTRY SUPPORT
  • 830222 005874 C20H001 RB SUPPORT ACTIVITY 4 OP 0.000 2.08 RB ENTRY SUPPORT
  • 830222 005874 C20H001 RB SUPPORT ACTIVITY 1 SE 0.000 0.82 RB ENTRY SUPPORT

$830222 005874 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 2.70 RB ENTRY SUPPORT

  • S30222 005874 C20H001 RB SUPPORT ACTIVITY 1 MM 0.000 2.63 RB ENTRY SUPPORT
  • 830222 005814 C20H001 RB SUPPORT ACTIVITY 1 RC 0.000 0.68 RB ENTRY SUPPORT 830222 005875 C20H001 RB SUPPORT ACTIVITY 15 CN 0.159 27.48 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830222 005876 C20H001 RB $UPPORT ACTIVITY 2 CN 0.C30 4.27 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830222 005876 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 0.90 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK

$830222 005876 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.68 RB ENTRY SUPPOR T - EQUIPME NT AIRLOCK 830222 005877 C30E001 DECON RB D RINGS 2 UM 0.395 5.47 REMOTE FLUSH OF 'D' RING / SORT TOCLS

  • 830222 005877 C30E001 DECON RB D RINGS 1 OP 0.143 2.18 REMOTE FLUSH OF

'D' RING / SORT TOCLS

  • 830222 005877 C30E001 DECON RB D RINGS 1 CM 0.142 2.25 REMOTE FLUSH OF
  • D' RING / SORT 10ELS 830223 005901 C30M001 DECON SERVICE STRUCT 1 EL 0.255 2.37 DECON REFUELING CANAL
  • 830223 005901 C30M001 DECON SERVICE STRUCT 1 OP 0.228 2.50 DECON REF UE LING CANAL
  • 830223 005901 C30M001 DECON SERVICE STRUCT 1 UM 0.232 2.33 DECON REFUELING CANAL
  • 830223 005901 C30M001 DECON SERVICE STRUCT 1 MM 0.225 2.23 DECON REFUE LING CANAL 8

830223 005902 C20H002 RB - CCTV 2 IC 0.130 2.58 INSPECT / REPAIR CCTV CAMERA 6 45 830224 005914 C30D001 RB DECON-282' ELEV 2 CN 0.383 1.83 OPEN ELEVATOR DOORS ON 305' LEVEL W 830224 005916 C30D001 RB DECON-232' ELEV 2 OP 0.351 2.47 FLUSH 'D' RINGS & LINER PLATE WALLS

  • 830224 005916 C30D001 RB DECON-282' ELEV 1 UM 0.220 1.65 FLUSH

'D' RINGS & LINER PLATE WALLS

  • 830224 005916 C30D001 RB DECON-282' ELEV 1 CM 0.039 1.33 FLUSH

'D' RINGS & LINER PLATE WA>LS 830224 005917 C20H001 RB SUPPORT ACTIVITY 1 UM 0.194 2.15 TRASH AND TOOL REMOVAL

  • 830224 005917 C20H001 RB SUPPORT ACTIVITY 1 MM 0.211 1.98 TRASH AND TOOL REMOVAL 830228 005944 C20H001 RB SUPPORT ACTIVITY 56 CN 0.011 269.28 DISMANTLE / ERECT CONT CNTRL CORR /) ECON
  • 830228 005944 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 6.87 DISMANTLE / ERECT CONT CNTRL CORR /3ECCN 830228 005948 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 8.72 OPERATE AND MAINTAIN NLB PUMP 830302 005956 C20H001 RB SUPPORT ACTIVITY 7 CN 0.000 13.19 RB ENTRY SUPPORT - ANTEROOM
  • 830302 005956 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.18 RB ENTRY SUPPORT - ANTEROOM
  • 830302 005956 C20H001 RB SUPFORT ACTIVITY 1 HP 0.000 1.10 RB ENTRY SUPPORT - ANTEROOM 830302 005957 C20H001 RB SUPPORT ACTIVITY 18 CN 0.107 0,00 RB E NTRY SUPPOR T - EQUIPMENT AIRLOCK
  • 830302 005957 C20H001 RB SUPPORT ACTIVITY 4 HP 0.000 11.38 RB ENTRY SUPPORT - EQUIPMENT AIR 10CK
  • 830302 005957 C20H001 RB SUPPORT ACTIVITY I RC 0.000 4.48 RB E NTRY SUPPOR T - EQUIPMENT AIRLOCK 830302 005969 C20H002 RB - CCTV 1 EL 0.074 1.57 INSTALL !!O VOLT POWER TO P.C.

COTV

  • 830302 005969 C20H002 RB - CCTV 3 CN 0.310 4.81 INSTALL 110 VOLT POWER TO P.C.

C3TV 830304 005983 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 4.48 DECON AREA OVER EQUIPMENT HATCH 830307 005988 C20H001 RB SUPPORT ACTIVITY 26 CN 0.014 80.82 RB ENTRY SUPPORT - ALL AREAS

  • 830307 005988 C20H001 RB SUPPORT ACTIVITY 26 HP 0.019 153.54 RB ENTRY SUPPORT - ALL AREAS
  • 830307 005988 C20H001 RB SUPPORT ACTIVITY 3 OP 0.013 3.70 RB ENTRY SUPPORT - ALL AREAS
  • 830307 005988 C20H001 RB $UPPORT ACTIVITY 3 MM 0.012 4.67 RB ENTRY SUPPORT - ALL AREAS
  • 830307 005988 C20H001 RB SUPPORT ACTIVITY

! UM 0.000 0.25 RB ENTRY SUPPORT - ALL AREAS 830307 005989 C20H001 RB SUPPORT ACTIVITY 47 CN 0.265 85.35 RB ENTRY SUPPORT - EQUIPMENT HATOH

  • 830307 005989 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.05 RB ENTRY SUPPORT - EQU1PMENT HATCH
  • 830307 005989 C20H001 RB SUPPORT ACTIVITY 3 MM 0.005 1.70 RB ENTRY SUPPORT - EQUIPMENT HAT:H
  • 830307 005989 C20H001 RB SUPPORT ACTIVITY 3 HP 0.000 4.35 RB ENTRY SUPPORT - EQUIPMENT HAT 3H 830307 006005 C20H001 RB SUPPORT ACTIVITY 9 CN 0.012 34.82 OPERATE AND MAINTAIN NLB PUMP 830309 006017 C35N003 DOSE REDUCTION-305' 4 CN 1.224 10.25 INSTALL PORTABLE SHIELDING DOLLY 830309 006018 C20H001 RB SUPPORT ACTIVITY I EL 0.216 1.85 TOOL INVENTORY AND CONTROL

DATE 022486 PAfE 29 PNO. 28 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D A T E... NUMB.E.R, NUMBE R.....................I.VITY.......

. C OD E.... R E M........ HOURS. TASK DESCRTPTION ACT ENTR 4.........

  • 830309 006018 C20H001 RB SUFPORT ACTIVITY 2 UM 0.677 4.02 TOOL INVENTORY AND CONTROL
  • 830309 006018 C20H001 RB SUFPORT ACTIVITY 1 MM 0.200 1.85 TOOL INVENTORY AND CONTROL
  • 830309 006018 C20H001 RB SUFPORT ACTIVITY 1 RP 0.354 2.12 TOOL INVENIORY AND CONTROL 830310 006019 C30C001 RB DECON-305* ELEV 2 OP 0.000 1.87 OVERHEAD FLUSH - 305' TO 347' L4VELS
  • 830310 006019 C30C001 RB DECON-305' ELEV 3 UM 0.483 5.18 OVERHEAD FLUSH - 305' TO 347' LEVELS
  • S'30310 006019 C30C001 RB DECON-305' ELEV 1 EL 0.180 1.65 OVERHEAD FLUSH - 305' TO 347' LiVELS
  • 830310 006019 C30C001 RB DECON-305' ELEV 3 MM 0.382 3.55 OVE RHE AD F LUSH - 305' TO 347' L!VELS
  • 830310 006019 C30C001 RB DECON-305' ELEV 1 CM 0.126 1.78 OVERHEAD FLUSt - 305' TO 347' LIVELS 830310 006020 C45H001 RB COFRECTIVE MAINT 2 MM 0.238 2.48 SURVE Y INSIDE A!RLOCK DOORS 830311 006024 C30G018 DECON EXP LP MX/CANL 3 CN 0.382 4.87 REMOVE INTERFERENCES - RVHSS 830311 006026 C35N003 DOSE REDUCTION-305' 3 CN 0.262 225.00 STAGE MATERIALS 830314 006035 C30C001 RB DECON-305' ELEV 4 CN 1 541 8.05 DECON 305' LEVEL 830314 006036 C20H001 RB SUPPORT ACTIVITY 4 CN 0.017 6.42 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • E30314 006036 C20H001 RB SUPPORT ACTIVITY 3 MM 0.011 4.95 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830314 006037 C20H001 RB SUPPORT ACTIVITY 20 CN 0.201 41.50 RB E NTRY SUPPORT - PERSONNEL AI RLOCK
  • 830314 006037 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 1.12 RB ENTRY SUPPORT - PERSONNEL ATRLOCK 830314 006038 C20H001 RB SUPPORT ACTIVITY 93 CN 3.022 261.34 RB ENTRY SUPPORT - ALL AREAS
  • 830314 006038 C20H001 RB SUPPORT ACTIVITY 32 HP 0.006 178.47 RB ENTRY SUPPORT - ALL AREAS

$830314 006038 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.48 RB ENTRY SUPPORT - ALL AREAS e *830314 006038 C20H001 RB SUPPORT ACTIVITY 1 AM 0.000 0.28 RB ENTRY SUPPORT - ALL AREAS 45 830314 006050 C20H001 RB SUPPORT ACTIVITY 14 CN 0.005 44.08 OPERATE AND MAINTAIN NLB PUMP 45 830315 006055 C30D001 RB DECON-282' ELEV 2 CN 0.250 2.82 3 EMOTE DECON/ TOOL INVENTORY - 182* LEVEL s 830315 006056 C30P001 DECON AIR COOLERS 2 HP 0.613 3.72 SURVEY AIR COOLERS & HANDLING JNITS 830315 006068 C45H001 RB CORRECTIVE MAINT 2 CN 0.114 2.17 REPLACE P.C. TEMPORARY POWER FIED 830316 006069 C30P001 DECON AIR COOLERS 1 MM 0.027 0.63 REMOTE FLUSH CF AIR COOLERS

  • 830316 006069 C30P001 DECON AIR COOLfRS 2 IC 0.067 1.90 REMOTE FLUSH OF AIR COOLERS
  • 830316 006069 C30P001 DECON AIR COOLERS 1 OP 0.038 1.23 REMOTE FLUSH OF AIR COOLERS 830317 006073 C30P001 DECON AIR COOLERS 2 CM 0.143 3.62 DECON AIR COOLERS - 305' LEVE1
  • 830317 006073 C30P001 DECON AIR COOLERS 3 OP 0.379 5.08 DECON AIR COOLERS - 305' LEVE1
  • 830317 006073 C30P001 DECON AIR COOLERS 1 IC 0.126 2.00 DECON AIR COOLERS - 305 LEVEL 830318 006077 C70H001 RB RAD SURVEYS 1 HP 0.088 1.88 HP SURVEY /0TSG LEVEL CHECK 830318 006078 C30P001 DECON AIR COOLERS 2 CM 0.237 4.07 DECON AIR COOLERS
  • 830318 006078 C30P001 DECON AIR COOLERS 1 UM 0.143 2.33 DECON AIR COOLERS
  • 830318 006078 C30P001 DECON AIR COOLERS 3 OP 0.333 5.12 DECON AIR COOLERS
  • 830318 006078 C30P001 DECON AIR COOLERS 1 MM 0.096 1.63 DECON AIR COOLERS
  • 830318 006078 C30P001 DECON AIR COOLERS 1 IC 0.132 2.50 DECON AIR COOLERS 830319 081739 C20H001 RB SUPPORT ACTIVITY 1 CR 0.005 0.00 CLEAN PERSONNEL AIRLOCK

$830319 0817J9 C20H001 RB SUPFORT ACTIVITY 5 CN 0.150 6.42 CLEAN PERSONNEL AIRLOCK 830321 006085 C20H001 PB SUPPORT ACTIVITY 5 CN 0.047 11.35 RB ENTRY SUPPOR T - EQUIPMENT A IRLOCK 830321 006088 C70H001 RB RAD SURVEYS 1 HP 0.091 1.02 HP SURVEY OF NEUTRON SHIELD /0"SG CHECK 830321 006089 C30P001 DECON AIR COOLERS 2 CN 0.355 1.90 DECON AIR COOLERS

  • 830321 006089 C30P001 DECON AIR COOLERS 1 HP 0.006 1.45 DECON AIR COOLERS
  • 830321 006089 C30P001 DECON AIR COOLERS 2 OP 0.250 2.62 DECON AIR COOLERS 830321 006091 C20H001 RB SUPPORT ACTIVITY 14 CN 0.106 29.13 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830321 006092 C20H001 RB SUPPORT ACTIVITY 63 CN 0.012 144.95 RB ENTRY SUPPORT - ALL AREAS
  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 30 HP 0.006 146.27 RB ENTRY SUPPORT - ALL AREAS
  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 1 AD 0.000 0.27 RB ENTRY SUPPORT - ALL AREAS
  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 1 AM 0.005 0.28 RB ENTRY SUPPORT - ALL AREAS
  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 1 MD 0.000 0.08 RB ENTRY SUPPORT - ALL AREAS
  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.93 RB ENTRY SUPPORT - ALL AREAS

m____sm-. -_______m -_.m_.. .. ~ _., _.. _ _ _ __ i l r i DATE 022486 PAGE 30 PNO 29 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDINO DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PE R S. DEPT. EXPOS. TIME

  • DATE

.N

  • ........ UMBER. NUMBER.......................TIVITY.............

AC E. N T R ........ E.... R E. M..... H. OU R S...................S.K.. DESCRIPTION . COD TA q 7 830321 006107 C20H001 RB SUPPORT ACTIVITY......... I 9 CN 0.000. 38.27 OPERATE AND MAINTAIN NLB PUMP

  • 830321 006107 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.50 OPERATE AND MAINTAIN NLB PUMP

'830322 003340 C30G001 DECON EXP-SDS SURVEY 2 HP 0.045 2.08 HP SURVEYS /DECON EXPERIMENT C0VERACE j

  • 830322 003340 C30G001 DECON EXP-SDS SURVEY 3 CN 0.578 4.95 HP SURVEYS /DECON EXPERIMENT COVERAGE 830322 006114 C30P001 DECON AIR COOLERS 1 MM 0.060 1.43 DECON AIR COOLERS
  • 830322 006114 C10P001 DECON AIR COOLERS 1 UM 0.206 1,63 DECON AIR COOLLRS
  • 870??2 006114 C30P001 DECON AIR COOLERS 1 OP 0.193 1.63 DECON AIR COOLERS 830322 006120 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 5.52 REMOVE BLIND *LANGE/ INSTALL VALVE l

830322 006121 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 2.53 REMOVE BLIND FLANGE / INSTALL VALVE 830323 006123 C35N003 DOSE REDUCTION-305' 3 CN 0.828 2.98 INSTALL SHIELD SUPPORT IN OPEN STAIRWELL 830325 006134 C35N003 DOSE REDUCTION-305' 1 OP 0.173 1.63 SHIELD OPEN STAIRWELL AND HATCH

  • 830325 006134 C35N003 DOSE REDUCTION-305' 1 EL 0.165 1.60 SHIELD OPEN STAIPWELL ANO HATCH
  • 830325 006134 C35N003 DOSE REDUCTION-305' 1 CM O.161 1.70 SHIELD OPEN STAIRWELL AND HATCH
  • 830325 006134 C35N003 DOSE REDUCTION-305*

1 MM 0.259 1.55 SHIELD OPEN STAIRWELL AND HATCH

  • 830325 006134 C35N003 DOSE REDUCTION-305' 2 IC 0.266 2.92 SHIELD OPEN STAIRWELL AND HATCH 830325 006135 C35N003 DOSE REDUCTION-305' 4 CN 1.067 3.25 INSTALL SUPPORTS IN OPEN STAIRWELL 830325 006136 C30P001 DECON AIR COOLERS 2 HP 0.594 2.40 FLUSH AIR COOLERS
  • 830325 006136 C30P001 DECON AIR COOLERS 5 CN 1.865 10.96 FLUSH AIR COOLERS 8830325 006136 C30P001 DECON AIR COOLERS 1 CM 0.406 1.37 FLUSH AIR COOLERS i
  • 830325 006136 C30P001 DECON AIR COOLERS.

1 UM 0.205 1.17 FLUSH AIR COOLERS , *830325 006136 C30P001 DECON AIR COOLERS 1 MM 0.476 1.30 FLUSH AIR COOLERS a *830325 006136 C30P001 DECON AIR COOLERS 2 OP 0.203 5.50 FLUSH AIR COOLERS c1 -830328 006140 C30P001 DECON AIR COOLERS 2 HP 0.326 1.57 FLUSH AIR COOLERS s *830328 006140 C30P001 DECON AIR COOLERS 2 OP 0.378 2.48 FLUSH AIR COOLERS $30328 006143 C35N003 DOSE REDUCTION-305* 1 EL 0.121 1.15 INSTALL SHIELDING AT COVERED HATCH-

  • 830328 006143 C35N003 DOSE REDUCTION-305*

2 CM 0.175 2.18 INSTALL SHIELDING AT COVERED HATCH

  • 830328 006143 C35N003 DOSE REDUCTION!305*

2 FH 0.198 2.25 INSTALL SHIELDING AT COVERED HATCH

  • S30328 006143 C35N003 DOSE REDUCTION-305' 1 UM 0.085 1.20 INSTALL SHIELDING AT COVERED HATCH
  • G30328 006143 C35N003 DOSE REDUCTION-305' 2 IC 0.238 3.17 INSTALL SHIELDING AT COVERED HATCH i

830328 006147 C20H001. RB SUPPORT ACTIVITY 56 CN 0.047 132.62 RB ENTRY SUPPORT - ALL CONTROLLED AREAS i

  • 830328 006147 C20H001 RB SUPPORT ACTIVITY 20 HP 0.015 124.20 RB ENTRY SUPPORT - ALL CONTROLLED ARE AS
  • 830328 006147 C20H001 RB SUPPORT ACTIVITY 4 RC 0.014 26.52 RB ENTRY SUPPORT - ALL CONTROLLED AREAS
  • 830328 006147 C20P001 RB SUPPORT ACTIVITY 1 OP 0.000 0.63 RB ENTRY SUPPORT - ALL CONTROLLED AREAS a
  • 830328 006147 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 0.45 RB ENTRY SUPPORT - ALL CONTROLLED AREAS 830328 006148 C20H001 RB SUPPORT ACTIVITY 12 CN 0.076 21.00 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 1

830328 006150 C20H001 RB SUPPORT ACTIVITY 6 CN 0.005 34.67 OPERATE AND MAINTAIN NLB PUMP S30328 006161 C20h001 RB SUPPORT ACTIVITY 2 CN 0.289 3.22 TRASH REMOVAL 830329 006162 C30P001 DECON AIR COOLERS 1 HP 0.260 1.22 OTSG LEVEL CHECK / SURVEY AIR COOLER 830320 006163 C20H001 RB SUPPORT ACTIVITY 2 CN 0.491 5.52 TRASH AND TOOL REMOVAL 830329 006165 C30P001 DECON AIR COOLERS 2 OP 0.103 1.33 DECON AIR COOLERS / COVER MANWAY i 830329 006174 C30P001 DECON AIR COOLERS 1 RC 0.290 1.33 DECON AIR COOLERS / SWITCH N0ZZLE 2

  • S30329 006174 C30P001 DECON AIR COOLERS 4 OP 0.497 3.17 DECON AIR COOLERS / SWITCH N0ZZLE 1

830330 006177 C35N003 DOSE REDUCTION-305' 2 OP 0.242 1.18 SHIELD OPEN STAIRWELL / FLUSH COOLERS i

  • 830330 006177 C35N003 DOSE REDUCTION-305' 1 EL 0.055 0.70 SHIELD OPEN STAIRWELL / FLUSH COOLERS l
  • 830330 006177 C35N003 DOSE REDUCTION-305' 1 CM 0.055 0.75 SHIELD OPEN STAIRWELL / FLUSH COOLERS i

830404 006201 C20H001 RB SUPPORT ACTIVITY 7 CN 0.006 10.90 OPERATE AND MAINTAIN NLB PUMP 830405 006209 C20H001 RB SUPPORT ACTIVITY 6 CN 0.054 11.07 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 2

  • 830405 006209 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.88 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830405 006210 C20H001 RB SUPPORT ACTIVITY 41 CN 0.027 107.72 RB ENTRY SUPPaRT - ALL AREAS a,
  • 830405 006210 C20H001 RB SUPPORT ACTIVITY 16 HP 0.002 75.58 RB ENTRY SUPPORT - ALL AREAS a

l l i 4

DATE 022486 PAGE 31 PNO. 30 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME . CODE. REM , HOUR TASK DESCRIPTION .............,....S.........,........................................,

  • D. A TE..,. NUMBE.R. NUMB E R...................IVITY ENTR ACT

........s.........,...... . 0.000 1.32 RB ENTRY SUPPORT - ALL AREAS

  • 830405 006210 C20H001 RB SUPPORT ACTI'IITY 2 OP
  • 830405 006210 C20H001 RB SUPPORT ACTIVITY 1 CM 0.000 1.45 RB ENTRY SUPPORT - ALL AREAS
  • 830405 006210 C20H001 RB SUPPORT ACTIVIIY 1 AM 0.000 0.08 RB ENTRY SUPPORT - ALL AREAS
  • 830405 006210 C20H001 RB SUPPORT ACTIVITY I UM 0.000 2.63 RB ENTRY SUPPORT - ALL AREAS 830405 006211 C20H001 RB SUPPORT ACTIVITY 1 CN 0.021 3.32 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830405 006212 C70H001 RB RAD SURVEYS 3 HP 0.706 8.98 DIRECTIONAL RADIATION SURVEY OF RB
  • 830405 C06212 C70H001 RB RAD SURVEYS 1 CN 0.202 1.65 DIRECTIONAL RADIATION SURVEY OF RB 830405 006216 C90K001 RB DATA ACQUISITION 2 CN 0.409 5.47 TV SURVEY OF TRASH RACK 830405 006218 C35N003 DOSE REDUCTION-305' 1 EL O.391 1.35 SHIELD OPEN STAIRWELL / REPLACE PAN TILT
  • 830405 006218 C35N003 DOSE REDUCTION-305' 1 CM 0.210 1.28 SHIELD OPEN STAIRWELL / REPLACE PAN TILT
  • 330405 006218 C35N003 DOSE REDUCTION-305' 1 UM 0.242 1.38 SHIELD OPcN STAIRWELL / REPLACE PAN TILT
  • 830405 006218 C35N00' DOSE REDUCTION-305' 2 IC 0.614 3.28 SHIELD OPEN STAIRWELL / REPLACE PAN TILT
  • 830405 006218 C35N003 DOSF REDUCTION-305*

1 OP 0.275 1.38 SHIELD OPEN STAIRWELL / REPLACE PAN TILT 830406 006213 C70H001 RB RAD SURVEYS 1 HP 0.138 1.07 HP SURVEY / JOB COVERAGE /0TSG CHECK 830406 006221 C90K001 RB DATA ACQUISITION 2 CN 0.126 3.18 RB WALKDOWN 830407 006222 C35N003 DOSE REDUCTION-305' 1 'O P 0.045 0.80 INSTALL SHIELDING ON COVERED HATCH

  • 830407 006222 C35N003 DOSE REDUCTION-305' 1 EL 0.075 0.63 INSTALL SHIELDING ON COVERED HATCH
  • 830407 006222 C35N003 DOSE REDUCTION-305' 1 CM 0.046 0.73 INSTALL SHIELDING ON COVERED HATCH
  • 830407 006222 C35N003 DOSE REDUCTION-305' 1 IC 0.050 0.63 INSTALL SHIELDING ON COVERED HATCH
  • 830407 006222 C35N003 DOSE REDUCTION-305*

1 OP 0.041 0,75 INSTALt SHIELDING ON COVERED HATCH 830411 006241 C20H001 RB SUPPORT ACTIVITY 2 CN 0.356 3.93 SURVEY FOR TRASH REMOVAL /PHOTCGRAPHS Cn 830411 006243 C20H001 RB SUPPORT ACTIVITY 3 CN 0.031 5.03 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 43 s 830411 006244 C20H001 RB SUPPORT ACTIVITY 6 CN 0.070 12.00 RB ENTRY SUPPORT - PERSONNEL AIRLOCK

  • 830411 006244 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.50 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830411 006245 C20H001 RB SUPPORT ACTIVITY 37 CN 0.069 93.80 RB ENTRY SUPPORT - ALL AREAS
  • 830411 006245 C20H001 RB SUPPORT ACTIVITY 14 HP 0.022 46.88 RB ENTRY SUPPORT - ALL ARE AS
  • 830411 006245 C20H001 RB SUPPORT ACTIVITY 2 SE 0.000 1.22 RB ENTRY SUPPORT - ALL AREAS
  • 830411 006245 C20H001 RB SUPPORT ACTIVITY 1 RC 0.000 4.13 RB ENTRY SUPPROT - ALL AREAS
  • 830411 006245 C20H001 RB SUPPORT ACTIVITY 2 CM 0.000 2.52 RB ENTRY SUPPORT - ALL AREAS 830411 006260 C20H001 RB SUPPORT ACTIVITY 4 CN 0.009 20.17 OPERATE AND MAINTAIN NLB PUMP 830414 003565 C30G001 DECON EXP-SDS SURVEY I HP 0.089 1.33 HP SURVEYS / JOB COVERAGE 830415 006274 C20H001 RB SUPPORT ACTIVITY 4 RP 0.016 8.75 REMOVE TRASH - ANTEROOM TO SFC ROOM
  • 830415 006274 C20H001 RB SUPPORT ACTIVITY 1 BS 0.005 1.32 REMOVE TRASH - ANTER0OM TO SFC ROOM S30415 006275 C35N003 DOSE REDUCTION-305*

2 CM 0.196 2.02 SHIELD OPEN STAIRWELL WITH LEAD BLANKETS

  • 830415 006275 C35N003 DOSE REDUCTIOM-305' 1 MM 0.123 1.08 SHIELD OPEN STAIRWELL WITH LEAD BLANKETS
  • 830415 006275 C35N003 DOSE REDUCTION-305' 1 IC 0.130 0.93 SHIELD OPEN STOIRWELL WITH LEAD BLANKETS 830415 006276 C20H001 RB SUPPORT ACTIVITY 3 CN 0.558 6.42 TRASH AND P.C.

SRAKES REMOVAL 830415 006277 C35N004 DOSE REDUCTION-282* 3 CN 0.364 4.39 RAISE ELEVATOR MECHANICALLY

  • 830415 006277 C35N004 DOSE REDUCTION-282*

1 HP 0.209 1.63 RAISE ELEVATOR MECHANICALLY 830415 0062/8 C70H001 RB RAD SURVEYS 1 HP 0.380 2.18 HP SURVEY / JOB COVERAGE /0TSG CHECK 830415 006279 C70H001 RB RAD SURVEYS 5 HP 1.832 11.58 DIRECTIONAL SURVEY OF CONTAINMENT

  • 830415 006279 C70H001 RB RAD SURVEYS 1 CN 0.438 1.92 DIRECTIONAL SURVEY OF CONTAINMENT 830415 006280 C20H001 RB SUPPORT ACTIVITY 1 RP 0.055 1.12 TRASH REMOVAL 830418 006297 C20H001 RB SUPPORT ACTIVITY 5 CN 0.005 7.78 OPERATE AND MAINTAIN NLB PUMP 830421 006311 C20H001 RB SUPPORT ACTIVITY 18 CN 0.019 40.26 RB ENTRY SUPPORT - ALL AREAS
  • 830421 006311 C20H001 RB SUPPORT ACTIVITY 8 HP 0.005 36.32 RB ENTRY SUPPORT - ALL AREAS 830421 006312 C20H001 RB SUPPORT ACTIVITY 4 CN 0.037 6.80 RB ENTRY SUPPORT - AIRLOCK 830421 006313 C20H001 RB SUPPORT ACTIVITY 1 CN 0.005 1.72 RB ENIRY SUPPORT - EQUIPMENT AIRLOCK 830421 006314 C50H001 RB P.M.

AND SURVEY I IC 0.300 3.05 TEST F IRE SERVICE DE TECTORS

  • 830421 006314 C50H001 RB P.M. AND SURVEY 1 RP 0.184 2.07 TEST FIRE SERVICE DETECTORS

DATE 052286 PAGE 32 PNO. 31 RID 24 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE.. NUMBER.NUMBE.R.............IVITY........................... CODE

.................ESCRIPTION ACT ENTR . REM . HOURS TASK D 830421 006315 C70H001 RB RAD SURVEYS 3 HP 0.679 6.07 HP SURVEY / JOB COVERAGE 830421 006317 C45H001 RB CORRECTIVE MAINT 1 AD 0.255 1.52 INSTALL FAN PROTECTION / SAFETY INSPECTION

  • 830421 006317 C45H001 RB CORRECTIVE MAINT 1 AM 0.156 1.40 INSTALL FAN PROTECTION / SAFETY INSPECTION 830421 006318 C30P001 DECON AIR COOLERS 1 HP 0.094 2.01 PUMP OUT ELEVATOR SHAFT / PHOTO CLR PANELS
  • 830471 006318 C30P001 DECON AI.i COOLERS 1 OP 0.269 1.48 PUMP OUT ELEVATOR SHAFT / PHOTO CLR PANELS 830422 003640 C30G001 DECON EXP-SDS SURVEY 1 HP 0.025 0.63 HP SURVEY / AIR SAMPLE 830425 006344 C20H001 RB SUPPORT ACTIVITY 10 CN 0.000 30.15 OPERATE AND MAINTAIN htB PUMP 830427 006352 C20H001 RB SUPPORT ACTIVITY 60 CN 0.029 147.97 RB ENTRY SUPPORT - ALL AREAS
  • 830427 006352 C20H001 RB SUPPORT ACTIVITY 20 HP 0.010 81.90 RB ENTRY SUPPORT - ALL AREAS
  • 830427 006352 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.23 RB ENTRY SUPPORT - ALL ARE AS 830427 006353 C20H001 RB SUPPORT ACTIVITY 20 CN 0.179 38.99 RB ENTRY SUPPORT - PERS & EQUIP AIRLOCKS
  • 830427 006353 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 15.18 RB ENTRY SUPPORT - PERS & EQUIP AIRLOCKS
  • 830427 006353 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.08 RB ENTRY SUPPORT - PERS & EQUIP AIRLOCKS 830427 006354 C70H001 RB RAD SURVEYS 1 HP 0.079 0.88 ROUTINE HP SURVEY 830427 006355 C20H001 RB SUPPORT ACTIVITY 2 CN 0.471 4.23 FIRE DETECTION SYSTEM WALFDOWN 830427 006356 C50H001 RB P.M.

AND SURVEY 1 IC 0.240 2.25 TEST FIRE SERVICE DETECTORS

  • 830427 006356 C50H001 RB P.M.

AND SURVEY 1 RP 0.290 2.15 TEST FIRE SERVICE DETECTORS 830427 006358 C35N005 DOSE REDUCTION-RVHSS 6 CN 1.578 16.32 INSTALL SCAFFOLD / LOWER SHIELD SUPPORTS

  • 830427 006358 C35N005 DOSE REDUCTION-RVHSS 1 MM 0.104 2.65 INSTALL SCAFFOLD / LOWER SHIELD SUPPORTS 830428 003702 C30G001 DECON EXP-SDS SURVEY 1 CN 0.255 2.87 HP SURVEY / JOB COVERAGE 830428 006361 C70H001 RB RAD SURVEYS 2 HP 0.656 5.52 HP SURVEYS / AIR SAMPLES 830428 006362 C30P001 DECON AIR COOLERS 2 UM 0.458 4.77 FLUSH AIR COOLERS / STAGE EQUIPMENT
  • 830428 006362 C30P001 DECON AIR COOLERS 1 10 0.160 2.28 FLUSH AIR COOLERS / STAGE EQUIPMENT 1830428 006362 C30P001 DECON AIR COOLERS 2 OP 0.242 2.97 FLUSH AIR COOLERS / STAGE EQUIPMENT 8
  • 830428 006362 C30P001 DECON AIR COOLERS 1 MM 0.261 2.50 FLUSH AIR COOLERS / STAGE EQUIPMENT 830428 006364 C35N005 DOSE REDUCTION-RVHSS 13 CN 2.369 30.28 INSTALL SCAFFOLD AND SHIELD SUPPORTS

]d

  • 830428 006364 C35N005 DOSE REDUCTION-RVHSS 2 EL 0.277 4.70 INSTALL SCAFFOLD AND SHIELD SUPPORTS 830429 006378 C20H001 RB SUPPORT ACTIVITY 1 IC 0.126 1.40 TOOL INVENTORY AND CONTROL
  • 830429 006378 C20H001 RB SUPPORT ACTIVITY 1 UM 0.165 1.32 TOOL INVENTORY AND CONTROL 830502 006396 C70H001 RB RAD SURVEYS 1 HP 0.025 1.50 HP SURVEY / JOB COVERAGE 830502 006399 C20H001 RB SUPPORT ACTIVITY 94 CN 0.043 223.04 RB ENTRY SUPPORT - ALL AREAS
  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 28 HP 0.015 138.95 RB ENTRY SUPPORT - ALL AREAS
  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.93 RB ENTRY SUPPORT - ALL AREAS
  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 3 RP 0.020 9.93 RB ENTRY SUPPORT - ALL AREAS
  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.37 RB ENTRY SUPPORT - ALL AREAS 830502 006400 C20H001 RB SUPPORT ACTIVITY 15 CN 0.123 29.10 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830502 006401 C20H001 RB SUPPORT ACTIVITY 4 CN 0,035 7.63 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830502 006404 C20H001 RB SUPPORT ACTIVITY 5 CN 0.C00 27.59 OPERATE AND MAINTAIN NLB PUMP
  • B30502 006404 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.53 OPERATE AND MAINTAIN NLB PUMP 830502 006405 C20H001 RB SUPPORT ACTIVITY 11 CN 0.094 32.85 REMOVE SPOOL / INSTALL HOSE 830503 006412 C80N001 RB WASTE REMOVAL 4 CN 0.069 6.35 TRASH REMOVAL - 305* LEVEL 830503 006413 C80N001 RB WASTE REMOVAL 2 RP 0.239 2.55 STRIP COAT WELDER 830503 006414 C70H001 RB RA'D SURVEYS 1 HP 0.085 1.52 HP SURVEY / STRIP COAT & WELDER COVERAGE 830504 006416 C80N001 RB WASTE REMOVAL 2 RP 0.013 6.33 PACKAGE HI RAD WELDER 830504 006420 C8CN001 RB WASTE REMOVAL 1 HP 0.166 2.37 SURVE Y FOR WE LDER & TRASH REMOVAL 830504 006422 C30M001 DECON SERVICE STRUCT 1 OP 0.190 1.77 FLUSH RV STUDS
  • 830504 006422 C30M001 DECON SERVICE STRUCT 1 RP 0.140 1.55 FLUSH RV STUDS
  • 830504 006422 C30M001 DECON SERVICE STRUCT 1 IC 0.095 1.78 FLUSH RV STUDS 830504 006425 C20H001 RB SUPPORT ACTIVITY 3 CN 0.599 6.05 TRASH REMOVAL /DECON INSPECTION 830504 006426 C80N001 RB WASTE REMOVAL 2 RP 0.044 1.40 WELDER REMOVAL

-, _. _ _ _. - ~. -,. - I l' 1 l l 1 DATE 022486 PAGE 33 i PNO. 32 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D ='

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS -. TIME ..... CODE........ REM........ HOURS.............. S.K..DE.S.C R I P f 1 GN TA

  • D. ATE... NUMBE. R. NU.MBE. R.............IVIT.Y

.E. N T R ACT l 3............ 830505 003765 C30G001 DECON EXP-SDS SURVEY 1 HP 0.390 3,08 HP SURVEY / JOB COVERAGE 830505 006431 C20H001 RB SUPPORT ACTIVITY 2 CN 0.425 5.15 INSPECTION - ALL LEVELS AND D RINGS INSPECTION - ALL LEVELS AND D RINGS

  • 830505 006431 C20H001 RB SUPPORT ACTIVITY 1 HP 0.135 2.62 -

530505 006432 C30M001 DEC3N SERVICE STRUCT 1 HP 0.280 3.00 FLUSH RV STUDS

  • 830505 006432 C30M001 DECON SERVICE STRUCT 2 OP 0.417 5.23 FLUSH RV STUDS t

t

  • 830505 006432 C30M001 DECCN SERVICE STRUCT 2 IC 0.391 4.87 FLUSH RV STUDS l
  • 830505 006432 C30M001 DECON SERVICE STRUCT 1 EL 0.295 2.40 FLUSH RV STUDS
  • 830505 006432 C30M001 DECON SERVICE STRUCT 1 MM 0.045 1.33 FLUSH RV STUDS 830506 006437 C30M001 DECOL SERVICE STRUCT 3 OP 0.493 5.55 FLUSH RV STUDS /DECON AIR C0OLERS
  • 830506 006437 C30M001 DECON SERVICE STRUCT 2 HP 0,279 3.18 FLUSH RV STUDS /DECON AIR COOLERS
  • 830506 006437 C30M001 DECON SERVICE STRUCT 1 IC-0.052 0.88 FLUSH RV STUDS /DECGN AIR COOLERS 1
  • 830506 006437 C30M001 DECON SERVICE STRUCT 1 MM 0.234 2.18 FLUSH RV STUDS /DECON AIR COOLERS l

830506 006438 C70H001 RB RAD SURVEYS 1 HP 0.130 1.12 HP SURVEY / TRASH REMOVAL 830509 006447 C20H001 RB SUS? ORT ACTIVITY IS CN 0.119 27.23 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830509 006448 C20H001 RB SUPFORT ACTIVITY 64 CN 0.053 164.17 RB ENTRY SUPPORT - ANTERDOM & AIRLOCKS 'l

  • 830509 006448 C20H001 RB SUPP)RT ACTIVITY 22 HP 0.053 93.15 RB ENIRY SUPPORT - ANTER0OM & AIRLOCKS
  • 830509 006448 C20H001 RB SUPPORT ACTIVITY 3 OP 0,005 3.70 RB ENTRY SUPPORT - ANIER00M & AIRLOCKS i

830509 006449 C20H001 R8 SUPPCRT ACTIVITY 3 CN 0.005 6.73 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830509 006451 C70H001 RB RAD SdRVEYS 1 HP 0.059 0.88 HP SURVEY / AIR SAMPLE / REMOVE RAP PUMP 4 830509 006452 C80N001 RB WASTE REMOVAL 2 CN 0.040 3.82 TRASH REMOVAL - 305* LEVEL 830509 006453 C30M001 DECON SEkVICE STRUCT 2 OP 0.246 2.52 FLUSH RV STUDS /DECON AIR COOLERS

  • 830509 006453 C30M001 DECON SERVICE STRUCT 1 EL 0.214 1.92 FLUSH RV STUDS /DECON AIR COOLERS 43 Co *830509 006453 C30M001 DECON SERVICE STRUCT 1 MM 0.174 1.95 FLUSH RV STUDS /DECON AIR COOLERS e 3830509 006453 C30M001 DECON SERVICE STRUCT 1 HP 0.136 2.08 FLUSH RV STUDS /DECON AIR COOLERS
  • 830509 006453 C30M001 DECON SERT!CE STRUCT 1 IC 0.231 0.67 FLUSH RV STUDS /DECON AIR COOLERS t

830509 006461 C20H001 RB SUPPORT ACTJVITY 13 CN 0.016 69.93 OPERATE AND MAINTAIN NLB PUMP a 830510 003805 C30G001 DECON EXP-CDS SURVEY ! HP 0.100 1.08 HP SURVEY / JOB COVERAGE 830510 006474 C30M001 DECON SERVICE STRUCT 2 HP 0.415 4,65 HP COVERAGE - RV HEAD FLUSH i 830510 006475 C30P001 DECON AIR C10LERS 2 OP-0.458 4.32 FLUSH RV STUDS AND AIR COOLERS

  • 830510 006475 C30P001 DECON AIR CiOLERS 2 UM 0.331 3.75 FLUSH RV STUDS AND AIR COOLERS
  • 830510 006475 C30P001 DECON AIR CE)LERS 1 IC 0.015 0.47 FLUSH RV STUDS AND AIR COOLERS
  • 830510 006475 C30P001 DECON AIR C01LERS 2 MM 0 366 3.32 FLUSH RV STUDS AND AIR COOLERS 830512 006480 C20H001 RB SUPPORT AC TIVITY 1 AM 0.186 2.02 CONTAINMENT SAFETY WALKDOWN 8830512 006480 C20H001 RB SUPPORT ACTIVITY 1 CN 0.164 2.07 CONTAINMENT SAFETY WALKDOWN 1 HP 0.143 1.48 HP SURVEY / JOB COVERAGE 830512 006482 C70H001 RB RAD SURVEY.:

18 CN 3.704 44.42 EQUIPMENT AND TRASH REMOVAL J 830512 006483 C20H001 RB SUPPORT ACTIVITY 830512 006485 C30P001 DECON AIR COOLERS 1 OP 0.037 20.70 CANAL CLEANUP / STAIRWELL FLUSH /CLR DECON i il . *830512 006485 C30P001 DECON AIR C00LdRS 1 IC 0.043 2.07 CANAL CLEANUP / STAIRWELL FLUSH /CLR DECON 830512 006487 C50H001 RB P.M. AND SUFVEY 2 IC 0.000 14.48 TRANSFER NEUTRON SOURCE / CALIBRATE INSTS

  • 830512 006487 C50H001 RB P.M. AND SURVEY 2 HP 0,000 1.13 TRANSFER NEUTRON SOURCE / CALIBRATE INSTS i'

830513 006491 C20H001 RB SUPPORT ACTI'/ITY 3 RP 0.058 6.15 TRASH REMOVAL - EQUIPMENT HATCH 830513 006493 C20H001 RB SUPPORT ACTIVITY 8 CN 2.040 17.58 EQUIPMENT AND TRASH REMOVAL 830513.006494 C30P001 DECON AIR COOLERS 1 UM 0.060 1.77 AIR COOLER DECON/ STAIRWELL FLUSH

  • 830513 006494 C30P001 DECON AIR COOLERS 1 MM 0.030 1.78 AIR COOLER DECON/ STAIRWELL FLUSH 830513 006499 C20H001 RB SUPPORT ACTIV;TY 3 CN 0.183 3.73 ENCLOSE STAIR SCAFFOLD i

830516 006500 C20H001 RB SUPPORT ACTIVITY 3 CN 0.026 10.12 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 3

  • 830516 006500 C20H001 RB SUPPORT ACTIVITY 6 RP 0.092 14.46 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830516 006501 C20H001 RB SUPPORT ACTIVITY 23 CN 0.147 36.93 RB ENTRY SUPPORT - PERSONNEL AIRLOCK
  • 830516 006501 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 5.90 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830516 006502 C20H001 RB SUPPORT ACTIVITY 1 CN 0.110 1.40 MEASURE WIRE R0PE/TAKE PHOTOS

l [ DATE 022486 PAGE 34 PNO. 33 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER ACTIVITY

............................ENTR. C OD E.... R E M . H O U R S.,.......................IPTION TASK DESCR 830516 006503 C20H001 RB SUPPORT ACTIVITY. 85 CN 0.086 210.72 RB ENTRY SUPPORT - ALL AREAS

  • 830516 006503 C20H001 RB SUPPORT ACTIVITY 28 HP 0.086 137.18 RB ENTRY SUPPORT - ALL AREAS
  • 830516 006503 C20H001 RB SUPPORT ACTIVITY 1 RP 0.013 2.78 RB ENTRY SUPPORT - ALL AREAS
  • 830516 006503 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.00 RB ENTRY SUPPORT - ALL AREAS 830516 006504 C30P001 DECON AIR COOLERS 1 OP 0.072 2.60 AIR COOLER DECON
  • 830516 006504 C30P001 DECON AIR COOLERS 1 MM 0.069 2.48 AIR COOLER DECON 830516 006505 C20H001 RB SUPPORT ACTIVITY 2 CN 0.590 4.55 TRASH AND EQUIFMENT REMOVAL 830516 006506 C70H001 RB RAD SURVEYS 1 HP 0.050 0.68 HP SURVE Y/0TSG CHECK / JOB COVERAGE 830516 006517 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 26.48 OPERATE AND MAINTAIN NLB PUMP 830517 006525 C70H001 RB RAD SURVEYS 1 HP 0.079 1.05 HP SURVEY / NEUTRON SURVEY OF VESSEL 830517 006526 C30P001 DECON AIR COOLERS 2 OP 0.160 3.58 AIR COOLER FLUSH
  • 830517 006526 C30P001 DECON AIR COOLERS 1 EL 0.074 1.62 AIR COOLER FLUSH
  • 830517 006526 C30P001 DECON AIR COOLERS 1 UM 0.086 1.50 AIR COOLER FLUSH 830517 006527 C20H001 RB SUPPORT ACTIVITY 1 IC 0.194 1.60 TRASH AbD EQUIPMENT REMOVAL
  • 830517 006527 C20H001 RB SUPPORT ACTIVITY 1 MM 0.147 1.58 TRASH AND EQUIPMENT REMOVAL 830517 006528 C20H001 RB SUPPORT ACTIVITY 1 CN 0.150 1,67 INSPECTION - ALL LEVELS AND CANAL 830518 006530 C20H001 RB SUPPORT ACTIVITY 3 CN 0.793 6.52 MOVE FRAMED ENCLOSURE 830518 006531 C70H001 RB RAD SURVEYS 1 HP 0.264 175.00 HP SURVE Y/ AIR SAMPLE / SHIELD SEISMIC GAP 830518 006532 C20H001 RB SUPPORT ACTIVITY 9 CN 1.394 18.08 TR ASH AND EQUIPMENT REMOVAL 830518 006533 C30P001 DECON AIR COOLERS 1 EL 0.050 0.83 AIR C00tER DECON/DESTAGE HOSES / MOVE SCAF e *830518 006533 C30P001 DECON AIR COOLERS 3 CN 1.106 3.73 AIR COOLER DECON/DESTAGE HOSES / MOVE SCAF 4h *830518 006533 C30P001 DECON AIR COOLERS 1 MM 0.055 0.88 AIR. COOLER DECON/DESTAGE HOSES / MOVE SCAF 830519 006538 C70H001 RB RAD SURVEYS 1 HP 0.240 1.53 HP SURVEY / AIR SAMPL E S 830519 006539 C20H001 RB SUPPORT ACTIVITY 2 CN 0.602 5.03 TRASH AND TOOL REMOVAL 830519 005540 C30P001 DECON AIR COOLERS 1 HP 0.070 1.00 AIR COOLER DECON/ REMOVE COVER / LOWER N0ZZ
  • 830519 006540 C30P001 DECON AIR COOLERS 1 OP 0.223 2.15 AIR COOLER DECON/ REMOVE COVER / LOWER N0ZZ
  • 830519 006540 C30P001 DECON AIR COOLERS 1 MM 0.150 2.12 AIR COOLER DECON/ REMOVE COVER / LOWER N0ZZ 830519 006557 C50H001 RB P.M. AND SURVEY 1 CN 0.000 3.48 TRANSFER NEUTRON SOURCE TO HOT SHOP c
  • 830519 006557 C50H001 RB P.M.

AND SURVEY 1 HP 0.000 1.58 TRANSFER NEUTRON SOURCE TO HOT SHOP 830520 006546 C80N001 RB WASTE REMOVAL 2 RP 0.300 3.10 TRASH REMOVAL FROM RB 830520 006547 C20H001 RB SUPPORT ACTIVITY 2 CN 0.225 2.67 SAFETY AND HOUSEKEEPING INSPECTION 830520 006550 C50H001 RB P.M. AND SURVEY 2 OP 0.349 2.43 SMOKE DETECTOR FUNCTIONAL TEST 830520 006551 C30P001 DECON AIR COOLERS 1 OP 0.010 0.42 AIR COOLER FLUSH

  • 830520 006551 C30P001 DECON AIR COOLERS 1 IC 0.015 0.52 AIR COOLER FLUSH

$830520 006551 C30P001 DECON AIR COOLERS 2 CN 0.055 1.03 AIR COOLER FLUSH 830520 006556 C80N001 RB WASTE REMOVAL 2 RP 0.060 3.97 TR ASH REMOVAL F ROM RB

  • 830520 006556 C80N001 RB WASTE REMOVAL 1 BS 0.028 2.57 TR ASH RE MOVAL FROM RB
  • 830520 006556 C80N001 RB WASTE REMOVAL 1 UM 0.060 2 57 TR ASH REMOVAL FROM RB 830523 006564 C20H001 RB SUPPORT ACTIVITY 2 CN 0.263 2.08 TRASH AND EQUIPMENT REMOVAL 830523 006565 C30P001 DECON AIR COOLERS 8 CN 0.267 3.70 AIR COOLER DECON 830523 006570 C20H001 RB SUPPORT ACTIVITY 79 CN 0.044 193.56 RB ENTRY SUPPORT
  • 830523 006570 C20H001 RB SUPPORT ACTIVITY 19 HP 0.007 107.60 RB ENTRY SUPPORT
  • 830523 006570 C20H001 RB SUPPORT ACTIVITY 2 RP 0.000 3.77 RB ENTRY SUPPORT 830523 006571 C20H001 RB SUPPORT ACTIVITY 1 CN 0.011 3.07 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830523 006571 C20H001 RB SUPPORT ACTIVITY 2 HP 0.002 2.17 RB ENTPY SUPPOR T - EQUI PME NT AIRLOCK
  • 830523 006571 C20H001 RB SUPPORT ACTIVITY 4 RP 0.030 7.61 RB ENTRY SUPPORT - EQUIPME NT AIR LOCK
  • 830523 006571 C20H001 RB SUPPORT ACTIVITY 2 MD 0.010 2.23 RB ENTRY SUPPOR T - EQUIPME NT AIR LOCK 830523 006571 C20H001 RB SUPPORT ACTIVITY 19 CN 0.117 30.13 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830523 006575 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 39.18 OPERATE AND MAINTAIN NLB PUMP 830524 006582 C80N001 RB WASTE REMOVAL 4 CN 0.031 4.47 TRASH REMOVAL FROM RB

DATE 022486 PAGE 35 PNO. 34 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ................. E S. C R I P T I. O N TASK D ACTIV ENTR. CODE. REM . HOURS ............ITY.............................................

  • DATE. NUMBER. NUMBER 830524 006584 C70H001 RB RAD SURVEYS 2 HP 0.118 2.03 JOB COVER AGE / REMOVE RMS-2 SYSTEM 830524 006585 C30P001 DECON AIR COOLERS 2 HP 0.307 1.57 AIR COOLER DECON/ REMOTE FLUSH
  • 830524 006585 C30P001 DECON AIR COOLERS 23 CN 2.136 16.33 AIR COOLER DECON/ REMOTE FLUSH 830524 006588 C50H001 RB P.M.

AND SURVEY 2 IC 0.000 1.63 TRANSFER NEUTRON SOURCE TO UNIT 1

  • 830524 006588 C50H001 RB P.M.

AND SURVEY 1 HP 0.000 1 58 TRANSFER N UTRON SOURCE TO UNIT 1 830524 006591 C50H001 RB P.M. AND SURVEY 8 CN 1.522 13.57 RE-ROUTE LLECTRIC. WATER & AIR LINES 830526 006593 C50H001 RB P M. AND SURVEY 2 CN 0.460 4.12 PHOTOGRAPHIC SURVEY OF CONTAINMENT 830527 006596 C20H001 R8 SUPPORT ACTIVITY 2 CN 0.409 3.37 FIRE DETfCTION SYSTEM WALKDOWN 830527 006598 C30P001 DECON AIR COOLERS 2 OP 0.057 1.10 AIR COOLER DECON/ REPOSITION LANCE

  • 830527 006598 C30P001 DECON AIR COOLERS 2 IC 0.161 1.45 AIR COOLER DECON/RE POSITIGN LANCE
  • 830527 006598 C30P001 DECON AIR COOLERS 2 UM 0.048 1.22 AIR COOLER DECON/PEPOSITION LANCE
  • 830527 006598 C30P001 DECON AIR COOLERS 2 MM 0.185 1.37 AIR COOLER DECON/ REPOSITION LANCE 830527 006600 C20H001 RB SUPPORT ACTIVITY I AD 0.077 1.02 SAFETY INSPECTION 830531 006611 C20H001 RB SUPPORT ACTIVITY 58 CN 0.028 118.67 RB ENTRY SUPPORT - ALL AREAS
  • 830531 006611 C20H001 RB SUPPORT ACTIVITY 20 HP 0.010 95.43 RB ENTRY SUPPORT - ALL AREAS
  • 830531 006611 C20H001 RB SUPPORT ACTIVITY 2 RP 0.000 2.33 RB ENTRY SUPPORT - ALL ARE AS
  • 830531 006611 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 3.25 RB ENTRY SUPPORT - ALL AREAS 830531 006612 C20H001 RB SUPPORT ACTIVITY 4 CN 0.020 6.27 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830531 006613 C20H001 RB SUPPORT ACTIVITY 9 CN 0.040 16.33 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830531 006614 C80N001 RB WASTE REMOVAL 4 CN 0.047 4.70 TRASH REMOVAL FROM RB 830531 006615 C50H001 RB P.M.

AND SURVEY 2 CN 0.072 1,43 PHOTOGRAPHIC SURVEY OF RB 830531 006616 C70H001 RB RAD SURVEYS 2 CN 0.197 2.23 HP SURVEY /MISCELLANE OUS JOB COVER AGE M

  • 830531 006616 C70H001 RB RAD SURVEYS 9 HP 1.051 13.77 HP SURVEY / MISCELLANEOUS JOB COVERAGE 830531 006617 C30P001 DECON AIR COOLERS 2 EL 0.049 0.88 AIR COOLER DECON o,
  • 830531 006617 C30P001 DECON AIR COOLERS 6 OP 0.417 3.42 AIR COOLER DECON
  • 830531 006617 C30P001 DECON AIR COOLERS 2 IC 0.123 1.18 AIR COOLER DECON
  • 830531 006617 C30P001 DECON AIR COOLERS 4 UM 0.310 2.30 AIR COOLER DECON
  • 830531 006617 C30P001 DECON AIR C00EERS 2 MM 0.193 1.22 AIR COOLER DECON 830531 006632 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 30.38 OPERATE AND MAINTAIN NLB PUMP 830602 006635 C30P001 DECON AIR COOLERS 3 OP 0.272 3.47 STAIRWELL FLUSH / AIR COOLER DECON
  • 830602 006635 C30P001 DECON AIR COOLERS 1 IC 0.149 2.22 STAIRWELL FLUSH / AIR COOLER DECON
  • 830602 006635 C30P001 DECON AIR COOLERS 2 UM 0.156 1.33 STAIRWELL FLUSH / AIR COOLER DECON 830603 006638 C35N003 DOSE REDUCTION-305*

3 RP 0.040 6.45 RECEIVE AND PACKAGE RESIN COLUMN 830603 006639 C30C001 RB DECON-305' ELEV 1 EL 0.040 0.65 FLUSH STAIRWELL - 347' & 305' LEVELS

  • 830603 006639 C30C001 RB DECON-305* ELEV 1 OP 0.015 0.77 FLUSH STAIRWELL - 347' & 305* LEVELS
  • 830603 006639 C30C001 RB DECON-305* ELEV 1 IC 0.050 0.65 FLUSH STAIRWELL - 347' & 305' LEVELS 830603 006640 C20H001 RB SUPPORT ACTIVITY 4 CN 0.287 5.33 INSTALL HANDRAIL 830603 006643 C35N003 DOSE REDUCTION-305*

2 RP 0.129 1.90 REMOVE RESIN COLUMN FROM RB 830606 00666 C20H001 RB SUPPORT ACTIVITY 9 CN 0.044 15.68 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 230606 006664 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 3.87 OPER ATE AND MAINTAIN NLB PUMP

  • 830606 006664 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 1.00 OPERATE AND MAINTAIN NLB PUMP 830606 006665 C20H001 RB SUPPORT ACTIVITY 1 CN 0.003 0.67 RB ENTRY SUPPORT - EOUIPMENT AIRLOCK 830606 006667 C20H001 RB SUPPORT ACTIVITY 36 CN 0.031 62,64 RB ENTRY SUPPORT - ALL AREAS
  • 830606 006667 C20H001 RB SUPPORT ACTIVITY 19 HP 0.017 108.42 RB ENTRY SUPPORT - ALL AREAS
  • 830606 006667 C20H001 RB SUPPORT ACTIVITY 3 RP 0.000 4.43 RB ENTRY SUPPORT - ALL AREAS
  • 830606 006667 C20H001 RB SUPPORT ACTIVITY t IC 0.000 0.50 RB ENTRY SUPPORT - ALL AREAS 830608 006673 C70H001 RB RAD SURVEYS 1 CN 0.157 1.63 HP SURVEYS / JOB COVERAGE
  • 830608 006673 C70H001 RB RAD SURVEYS 4 HP 0.568 4.77 HP SURVEYS / JOB COVERAGE 830608 006675 C20H001 RB SUPPORT ACTIVITY 1 OP 0.124 1.17 TRASH REMOVAL
  • 830608 006675 C20H001 RB SUPPORT ACTIVITY 1 UM 0.092 1.05 TRASH REMOVAL l

DATE 022486 PAGE 36 PNO. 35 .TMI-2 UNC-DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER. NUMBER.

ACTIVITY ENTR. CODE. REM . HOURS TASK DESCRIPTION 830608 006676 C45H001 RB CORRECTIVE MAINT 6 MM 0.281 12.60 SURVEY CONTAINMENT AND AIRLOCK 000RS 830609 006680 C50H001 RB P.M. AND SURVEY 1 IC 0.164 2 23 DECON 347' LEVEL

  • 830609 006680 C50H001 RB P.M AND SURVEY 1 UM 0.139 2.32 DECON 347' LEVEL
  • 830609 006680 C50H001 RB P.M. AND SURVEY 1 MM 0.146 2.30 DECON 347' LEVEL
  • 830609 006080 C50H001 RB P.M. AND SURVEY 2 CN 0.296 3.23 DECON 347' LEVEL

$830609 006680 C50H001 RB P.M. AND SURVEY I OP 0.162 2.42 DECON 347' LEVEL 830609 006681 C20H001 RB SUPPORT ACTIVITY 1 CN 0.002 1.10 TRASH REMOVAL 830609 006682 C20H001 RB SUPPORT ACTIVITY 1 CN 0.102 1.32 SAFETY AND HOUSEKEEPING INSPECTION

  • 830609 006682 C20H001 RB SUPPORT ACTIVITY 1 AD 0,104 1.35 SAFETY AND HOUSEKEEPING INSPECTION 830610 004040 C30G001 DECON EXP-SDS SURVEY 4 CN 0.631 6.50 LIQUID TRANSFER / RAD WASTE PACKAGING 830610 006688 C35N003 DOSE REDUCT10N-305' 2 CN 0.146 1.73 INSTALL SHIELDING AT FENETRATION 252 830610 006689 C20H001 RB SUPPORT ACTIVITY

? CN 0.274 2.47 INSTALL LADDER EXTENSION 830610 006690 C20H002 RB - CCTV 1 CM 0.151 1.45 MOVE TV CAMERA - 347' ELEV TO 372" ELEV

  • 830610 006690 C20H002 RB - CCTV 3 IC 0.388 5.95 MOVE.TV CAMERA - 347' ELEV TO 372' ELEV
  • 830610 006690 C20H002 RB - CCTV 1 UM 0.124 2.13 MOVE TV CAMERA - 347' ELEV TO 372' ELEV 830610 006695 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 2.35 INSTALL PIPE HANGERS F OR PROCESS WATER 830613 006714 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 7.58 OPERATE AND MAINTAIN NLB PUMP 830613 006719 C20H001 RB SUPPORT ACTIVITY 56 CN 0.015 112.03 RB ENTRY SUPPORT - ALL AREAS
  • 230613 006719 C20H001 RB SUPPORT ACTIVITY 15 HP 0.004 69.95 RB ENTRY SUPPORT - ALL AREAS 830613 006720 C20H001 RB SUPPORT ACTIVITY 10 CN 0.078 16.08 RB ENTRT SUPPORT - PERSONNEL AIRLOCK 830614 006722 C30P001 DECON AIR COOLERS O CN 0.207 4.43 FLUSH P.C.,

STAIRWELL & LOCA DUCT 830614 006723 C80N001 RB WASTE REMOVAL 1 UM 0.019 1.13 TRASH REMOVAL FROM SHIELDED AREA 830614 006725 C50H001 RB P M. ANO SURVEY 1 CN 0.021 0.70 PHOTO SURVE Y OF VALVE SFV-104 830614 006726 C20H001 RB SUPPORT ACTIVITY 1 CN 0.010 1.43 TR ASH RE MOVAL 830614 006729 C80N001 RB WASTE REMOVAL 2 RP 0.003 1.18 TRASH REMOVAL FROM ANTEROOM

  • 830614 006729 C80N001 RB WASTE REMOVAL 1 HP 0.000 0.57 TRASH REMOVAL FROM ANTER0OM 830615 006734 C45H001 RB CORRECTIVE MAINT 3 CN 0.122 3.92 REPAIR PENETRATION R-561 830615 006735 C90K001 RB DATA ACOUISITION 1 HP 0.187 2.62 INSPECT PAINT AND CONCRETE IN #B

$830615 006735 C90K001 RB DATA ACQUISITION 3 CN 0.524 7.51 INSPECT PAINT AND CONCRETE IN RB 830615 006739 C45H001 RB CORRECTIVE MAINT 9 CN 0.010 16.62 REMOVE PENE TRATION F LANGE AND RE TEST

  • 830615 006739 C45H001 RB CORRECTIVE MAINT 1 HP 0.005 6.08 REMOVE PE NE TR ATION F L ANGE AND RETE ST 830616 006742 C90K001 RB DATA ACQUISITION 3 CN 0.308 4.78 REMOVE CF T TRANSDUCERS 830616 006743 C20H002 RB - CCTV 2 IC 0.340 3.53 REPAIR TV CAMERAS 3& 7 830616 006745 C80N001 RB WASTE REMOVAL 2 RP 0.008 3.25 TRASH REMOVAL FROM ANTERDOM

$830616 006745 C80N001 RB WASTE REMOVAL 1 CN 0.000 0.73 TRASH REMOVAL F ROM ANTEROOM x830616 006745 C80N001 RB WASTE REMOVAL 1 OP 0.000 1.1' TRASH REMOVAL FROM ANTEROOM

  • S30616 006745 C80N001 RB WASTE REMOVAL 2 UM 0.002 2.35 TRASH REMOVAL FROM ANTEROOM 830617 006749 C50H001 RB P.M A.ND SURVEY 2 CN 0.214 3.68 PHOTO SURVEY OF CONTAINMENT - 347' LEVEL 830617 006750 C30C001 RB DECON-305' ELEV 1 MM 0.015 0.98 PREPARE AREA & EQUIP - 305' LEVEL
  • 830617 006750 C30C001 RB DECON-305' ELEV 1 UM 0.090 1.05 PREPARE AREA & EQUIP - 305' LEVEL 830620 006757 C30C001 RB DECON-305' ELEV 1 IC 0.059 1.67 FLUSH STAIRWELL - 305' & 347' L2VELS
  • 830620 006757 C30C001 RB DECON-305' ELEV 2 UM 0.089 2.15 FLUSH STAIRWELL - 305' & 347' LEVELS 2830620 006757 C30C001 RB DECON-305' ELEV 2 MM 0.092 2.10 FLUSH STAIRWELL - 305' & 347* LEVELS
  • 830620 006757 C30C001 RB DECON-305' ELEV 1 OP 0.101 1.57 FLUSH STAIRWELL - 305' & 347' LEVELS 830620 006758 C80N001 RB WASTE REMOVAL 1 CN O 009 1.33 ROUTINE TRASH REMOVAL 830620 006759 C70H001 RB RAD SURVE YS 7 HP 1.075 8.98 HP SURVEYS / JOB COVERAGE 830620 006760 C20H001 RB SUPPORT ACTIVITY 2 OP 0.268 2.22 TLD PLACEMENT - 305' ELEV INSIDE D RINGS
  • 830620 006760 C20H001 RB SUPPORT ACTIVITY I UM 0.420 1.18 TLD PLACEMENT - 305' ELEV INSIDE D RINGS 830620 006762 C20H001 RB SUPPORT ACTIVITY 14 CN 0.096 24.85 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830620 006763 C20H001 RB SUPPORT ACTIVITY 52 CN 0.017 116.42 RB ENTRY SUPPORT

DATE 022486 PAGE 37 PNO. 36 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..........IVITY............ ........ CODE........ REM.... HOURS...................ESCRIPTION ACT ENTR TASK D

  • DATE. NUMBER. NUMBER
  • 830620 006763 C20H001 RB SUPPORT ACTIVITY 20 HP 0.003 110.41 RB ENTRY SUPPORT

$830620 006763 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 1.93 RB ENTRY SUPPORT

  • 830620 006763 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 0.93 RB ENTRY SUPPORT 830620 006778 C20H001 RB SUPPORT ACTIVITY 11 CN 0.000 47.12 OPERATE AND MAINTAIN NLB PUMP
  • 830620 006778 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 0.L0 OPERATE AND MAINTAIN NLB PUMP 830622 006783 C30C001 RB DECON-305' ELEV 1 IC 0.025 0.87 STAIRWELL FLUSH

$830622 006783 C30C001 RB DECON-305' ELEV 1 OP 0.070 0.88 STAIRWELL FLUSH

  • 830622 006783 C30C001 RB DECON-305' ELEV 1 UM 0.061 1.58 STAIRWELL FLUSH
  • 830622 006783 C30C001 RB DLCON-305' ELEV 1 MM 0.051 1.58 STAIRWELL FLUSH 830622 006784 C30P001 DECON AIR COOLERS 5 CN 0.596 10.38 LOCA DUCT FLUSH
  • 830622 006784 C30P001 DECON AIR COOLERS 1 MM 0.075 1.22 LOCA DUCT FLUSH
  • 830622 006784 C30P001 DECON AIR COOLERS 3 EL 0.172 3.88 L OCA DUCT F LUSH 830622 006785 C45H001 RB CORRECTIVE MAINT 12 CN 0.005 23.82 CUT EXISTING LINES / BUILD SCAFFOLD S30622 006788 C30P001 DECON AIR COOLERS 1 OP 0.000 0.75 OPEN SFV-639
  • 830622 006788 C30P001 DECON AIR COOLERS 1 RP 0.000 0.77 OPEN SFV-639
  • S30622 006788 C30P001 DECON AIR COOLERS 2 HP O.000 0.97 OPEN SFV-639 330623 006791 C20H001 RB SUPPORT ACTIVITY I AD 0.083 1.05 SAFETY AND HOUSEKEEPING INSPECTION
  • 830623 006791 C20H001 RB SUPPORT ACTIVITY 1 CN 0,077 1.03 SAFETY AND HOUSEKEEPING INSPECTION 830623 006792 C50H001 RB P.M. AND SURVEY 6 CN 0.498 10.57 VISUAL & PHOTO INSPECTION OF PENETS 830624 006798 C50H001 RB P.M.

AND SURVEY 2 CN 0.083 1.63 PHOTO OF VALVE SFV-104 e 830627 006819 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 6.40 OPERATE AND MAINTAIN NLB PUMP tn *830627 006819 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.43 OPERATE AND MAINTAIN NLB PUMP BJ $30628 006822 C70H001 RB RAD SURVEYS 5 HP 0.800 6.93 HP SURVEYS / JOB COVE RAGE 830628 006823 C30C001 RB DECON-305' ELEV 4 CN 0.321 8.03 DECON LOCA DUCTS - P.C. & 347' LEVEL 1830628 006823 C30C001 RB DECON-305' ELEV 1 MM 0.104 1.72 DECON LOCA DUCTS - P.C. & 347' LEVEL

  • 830628 006823 C30C001 RB DECON-305* ELEV 1 EL 0.108 2.30 DECON LOCA DUCTS -

P.C. & 347' LEVEL $30628 006824 C30J001 RB DECON-347' ELEV 1 HP 0.221 228.00 DECON TEST SEAL PLATE

  • 830628 006824 C30J001 RB DECON-347' ELEV 6 CN 0.848 9.18 DECON TEST SEAT PLATE 830628 006825 C45H001 RB CORRECTIVE MAINT 2 CN 0.314 4,13 SNUBBER EVALUATION 630628 006826 C20H001 RB SUPPORT ACTIVITY 25 CN 0.047 42.27 RB ENTRY SUPPORT - ALL AREAS
  • 830628 006826 C20H001 RB SUPPORT ACTIVITY 10 HP 0.002 49.35 RB ENTRY SUPPORT - ALL AREAS
  • 830628 006826 C20H001 RB SUPPORT ACTIVITY 1 RP 0.002 5.07 RB E NTRY SUPPORT - ALL ARE AS
  • 830628 006826 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.68 RB ENTRY SUPPORT - ALL AREAS 830628 006827 C20H001 RB SUPPORT ACTIVITY 7 CN 0.051 12.60 RB ENTRY SUPPOR T - PERSONNEL AIRLOCK 830628 006828 C20H001 RB SUPPORT ACTIVITY 1 CN 0.013 4.69 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830629 006836 C80N001 RB WASTE REMOVAL 1 CN 0.042 1.45 ROUTINE TRASH REMOVAL 830629 006837 C50H001 RB P.M.

AND SURVEY 2 CN 0,162 3.17 PHOTO SURVEY & INSPECTION OF RB 830630 006847 C30F001 DECON RB CANAL 1 HP 0.009 2.47 DECON SOURCE RANGE PLATE $830630 006847 C30F001 DECON RB CANAL 1 RP 0.005 2.45 DECON SOURCE RANGE PLATE 830701 006849 C30D001 RB DECON-282* ELEV 3 CM 0.284 5.23 DECON AIR COOLERS

  • 830701 006849 C30D001 RB DECON-282' ELEV 1 UM 0.107 1.62 DECON AIR COOLERS
  • 830701 006849 C30D001 RB DECON-282 ' E LEV 1 RP 0.080 1.78 DECON AIR COOLERS
  • 830701 006849 C30D001 RB DECON-282* ELEV 1 CN 0.085 1.77 DECON AIR COOLERS 830701 006852 C80N001 RB WASTE REMOVAL 4 CN 0.370 5.65 SET UP WASTE TRANSFER POINT 830702 006866 C20H001 RS SUPPORT ACTIVITY 5 CN 0.023 15.84 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830702 006866 C20H001 RB SUPPORT ACTIVITV 1 OP 0.000 1.31 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830702 006867 C20H001 RB SUPPORT ACTIVITY 66 CN 0.017 167.44 RB ENTRY SUPPORT - ANTEROOM
  • 830702 006867 C20H001 RB SUPPORT ACTIVITY 14 HP 0.002 87.32 RB ENTRY SUPPORT - ANTEROOM
  • 830702 006867 C20H001 RB SUPPORT ACTIVITY 2 MM 0.000 4.47 RB ENTRY SUPPORT - ANTEROOM
  • 830702 006867 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.42 RB ENTRY SUPPORT - ANTERDOM e

- ~ ~ - - - - _.,. -. - ~. ~ - - - -. - - - - -. - -. ~ - - - - -... -. - - - - -.- - - _.- _ -. - - i i i l i DATE 022486 PAGE 38 i PN0 37 i .TMI-2 UNC:- DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINAT10N286 D l

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DA TE... NUMBE.R. NUMBE.R.............T..IVITY.......

.E.N T R..... CODE.... R E.M...........S......................SCRIPTION . HOUR TASK DE AC { i

  • 830702 006867 C20H001 RB SUPPORT ACTIVITY.

1 RP 0.002 7.12 RB ENTRY SUPPORT - ANTER0OM 830702 006868 C20H001 RB SUPPORT ACTIVITY 15 CN 0.126 28.87 RB ENTRY SUPPORT - PERSONNEL AIRLOCK i 830705 006860 C30P001 DECON AIR COOLERS 2 CM 0.413 3.18 FLUSH INSIDE AIR COOLERS + $830705 006860 C30P001 DECON AIR COOLERS 1 UM 0.326 1.60 FLUSH INSIDE AIR COOLERS i

  • 830705 006860 C30P001 DECON AIR COOLERS 1 CN 0.140 1,73 FLUSH INSIDE AIR COOLERS L

830705 006875 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 14.27 OPERATE AND MAINTAIN NLB PUMP } 830707 004228 C30G001 DECON EXP-SDS SURVEY I HP 0.050 2,75 HP SURVEY / JOB COVERAGE 1 830707 006891 C30J001 RB DECON-347' ELEV 1 HP 0.227 2.28 DECON INCORE INSTRUMENT TABLE '*830707 006891 C30J001 RB DECON-347' ELEV 1 RP 0.157 2.15 DECON INCORE INSTRUME NT TABLE

  • 830707 006891 C30J001 RB DECON-347' ELEV 1 CM 0.166 2.17 DECON INCORE INSTRUMENT TABLE I

830707 006898 C50H001 RB P.M. AND SudVEY 2 CN 0.248 4.03 TAG & INSPECT DECON EQUIP.-305 * & 347' 830708 006897 C20H001 RB SUPPORT ACTIVITY 2 CN 0.220 2.70 SAFETY AND HOUSEKEEPING INSPECTION 830708 006899 CGiK001 RB DATA ACQUISITION 2 IC 0.335 2.97 AH-C13 SWITCH REMOVAL 830709 006920 C20H001 RB SUPPORT ACTIVITY 16 CN 0.123 28.72 RB ENTRY SUPPORT - PERSONNEL AIRLOCK i 830709 006921 C20H001 RB SUPPORT ACTIVITY 2 CN 0.020 5.40 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK i 830709 006922 C20H001 RB SUPPORT ACTIVITY 75 CN 0.026 155.09 RB ENTRY SUPPORT - ANTER0OM $830709 006922 C20H001 RB SUPPORT ACTIVITY 23 HP 0.012 115.20 RB ENTRY SUPPORT - ANTER0OM t 1

  • 830709 006922 C20H001 RB SUPPORT ACTIVITY I RP 0.000 0.52 RB ENTRY SUPPORT - ANTERDOM i

l

  • 830709 006922 C20H001 RP SUPPORT ACTIVITY t OP 0.002 1.97 RB ENTRY SUPPORT - ANTER0OM 830711 006911 C70H001 RB RAD SUNVEYS la HP 1.066 15.97 HP SURVEYS / JOB COVERAGE W' 830711 006319 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 5.60 OPER%TE AND MAINTAIN NLB PUMP r

RB CECON-347' ELEV 1 MM 0.123 2.03 DECON SEAL TABLE AREA y *830711 006925 C30J001 830711 006925 C30J001 RB DECON-347' ELEV 1 CN 0.127 2.07 DECON SEAL TABLE AREA 830712 006932 C80N001 RB WASTE REMOVAL 3 UM 0.551 4.28 CLEAN UP 305' LEVEL

  • 830712 006932 C80N001 RB WASTE REMOVAL 3 CM 0.499 4.98 CLEAN UP 305' LEVEL 830712 006942 C90K001 RB DATA ACQUISITION 2 CN 0.234 2.63 REMOVE CABLE AND CONDUIT l

830713 006944 C80N001 RB WASTE REMOVAL 2 RP 0.000 5.17 REMOVE TRASH FROM PERSONNEL ANTEROOM

  • 830713 006944 C80N001 RB WASTE REMOVAL 1 CM 0.000 2.53 REMOVE TRASH FROM PERSONNEL ANTEROOM.

q i

  • 830713 006944 C80N001 RB WASTE REMOVAL 1 MM 0.002 2.57 REMOVE TRASH FROM PERSONNEL ANTEROOM d
  • 830713 006944 C80N001 RB WASTE REMOVAL 1 HP 0.000 2.15 REMOVE TRASH FROM PERSONNEL ANTEROOM i

830714 006950 C300001 RB DECON-282' ELEV 1 CM 0.102 1 97 FLUSH 282' LEVEL WALLS VIA SEISMIC GAP i

  • 830714 006950 C30D001 RB DECON-282* ELEV 1 MM 0.121 2.02 FLUSH 282' LEVEL WALLS VIA SEISMIC GAP 4
  • S30714 006950 C30D001 RB DECON-282' ELEV 1 EL 0,130 1.97 FLUSH 282' LEVEL WALLS VIA SEISMIC GAP
  • 830714 006950 C300001 RB DECON-282* ELEV 1 CN 0.100 2.03 FLUSH 282* LEVEL WALLS VIA SEISMIC GAP 830714 006951 C20H006 RB SAFETY INSPECTION 3 CN 0.342 4.60 NRC SAFETY INSPECTION
  • 830714 006951 C20H006 RB SAFETY INSPECTION 1 HP 0.095 1.73 NRC SAFETY INSPECTION I

830714 006952 C30J001 RB DECON-347' ELEV 1 CN 0.071 1.12 VACUUM BEHIND ELEVATOR SHAFT-347' LEVEL

  • 830714 006952 C30J001 RB DECON-347' ELEV 1 UM 0.078 1.18 VACUUM BEHIND ELEVATOR SHAFT-347' LEVEL 830714 006953 C20H006 RB SAFETY INSPECTION 3 CN 0.343 3.90 INSTALL SAFETY DEVICES I

830715 006961 C90K001 RB DATA ACQUISITION 4 CN 0.452 8.20 REPLACE LIMIT SWITCH-VALVE AH-V-28 . l 830715 006964 C20H001 RB SUPPORT ACTIVITY 2 CN 0.067 1.52 PENETRATION INSPECTION. i I 830715 006965 C50H001 RB P.M. AND SURVEY 1 MM 0.500 1.07 BUILDING INSPECTION - 305* & 347' LEVELS 2830715 006965 C50H001 RB P.M. AND SURVEY I UM 0.102 1.05 BUILDING INSPECTION - 305* & 347' '. E VE LS

  • 830715 006965 C50H001 RB P.M.

AND SURVEY 1 RP 0.063 0,S8 BUILDING INSPECTION - 305* & 347* LEVELS 830718 006978 C20H005 RB SUPP+0UTSIDE CTMT 3 CN 0.005 4.48 OPERATE NLB PUMP 830718 006983 C20H005 RB SUPP-0UTSIDE CTMT 50 CN 0.026 99.70 ANTEROOM SUPPORT FOR RB ENTRY i i 4830718 006983 C20H005 RB SUPP-0UTSIDE CTMT 23 HP 0.015 110.85 ANTEPOOM SUPPORT FOR RB ENTRY 830718 006984 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.016 1.83 EQUIPMENT AIRLOCK SUPPORT 830718 006985 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.054 15.25 PERSONNEL AIRLOCK SUPPORT j 830719 006989 C70H001 RB RAD SURVEYS 7 HP 0.941 11.23 HP SURVEYS / JOB COVERAGE e G ) i ) 1

DATE 022486 PAGE 39 PNO. 38 .THI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RwP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ........ REM . HOURS........... TASK D.ESCRIPTION . CODE ..........IVITYACT........... . ENTR

  • D. A TE... NUMBE R. NUMB E.R 3.................

830719 006998 C90K001 RB DATA ACQUISITION 2 CN 0.013 7.62. DISASSEMBLE. INSPECT AND WIPE SHUBSERS 830720 007000 C20H002 RB - CCTV 2 IC 0.753 3.63 REPAIR IV CAMERAS 3 4 5 830720 007002 C20H001 RB SUPPORT ACTIVITY 1 AD 0.138 2.18 SAFE TY AND HOUSEKEEPING INSPECTION

  • 830720 007002 C20H001 RB SUPPORT ACTIVITY 1 AM 0.117 2.12 SAFE TY AND HOUSE MEE PING INSPECTION 830721 007007 C90K001 RB DATA ACQUISITION 2 IC 0.335 3.02 DISCONNECT INCORE DETECTORS 830721 007009 C90K001 RB DATA ACQUISITION 2 CN 0.270 3.50 INSTALL TEMPORARY LIGHT STRINGER 830722 007021 C90K001 RB DATA ACQUISITION 5 CN 1.248 9.33 CORE BORE PENETRATION - 305' FLOOR
  • 830722 007021 C90K001 RB DATA ACQUISITION 1 HP 0.143 1.82 CORE BORE PENETRATION - 305' FLOOR 830722 007023 C35N003 DOSE REDUCTION-305' 4 CN 0.558 6.00 SET UP TEMPORARY STORAGE AREA 830725 007033 C70H001 RB RAD SURVEYS 5 HP 0.474 6.70 HP SURVE YS/ JOB COVERAGE 830725 007034 C20H005 RB SUPP-0UTSIDE CTMT 38 CN 0.007 90.88 ANTERDOM, DECON ROOM, EQUIPMENT HATCH
  • 830725 007034 C20H005 RB SUPP-0UTSIDE CTMT 12 HP 0.000 65.73 ANTEROOM. DECON ROOM. EQUIPMENT HATCH 830725 007035 C20H005 RB SUPP-0UTSIDE CTMT 11 CN 0.078 20.50 PERSONNEL AIRLOCK SUPPORT 830725 007054 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.000 1.00 OPERATE NLB PUMP 830725 007059 C90K001 RB DATA ACQUISITION 2 CN 0.198 3.52 CORE BORE PENETRATION / INSERT CAMERA 830726 007058 C20H006 RB SAFETY INSPECTION 1 AM 0.140 1.40 CABLE CHASE SAFETY INSPECTION 830729 007077 C90K001 RB DATA ACQUISITION 1 IC 0.102 1.10 DISCONNECT INCORE SHORTING DEVICES 830729 007083 C90K001 RB DATA ACQUISITION 4 CN 0.731 6.88 BORE 4 IN HOLE-305' TO RCDT ROOM 830801 007094 C70H001 RB RAD SURVEYS 3 HP 0.311 3.60 HP SURVEYS / JOB COVERAGE 830801 007099 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.004 0.82 EQUIPMENT AIRLOCK SUPPORT 830801 007100 C20H005 RB SUPP-0UTSIDE CTMT 9 CN 0.088 16.33 PERSONNEL AIRLOCK SUPPORT

,cn 830801 007101 C20H005 RB SUPP-0UTSIDE CTMT 16 CN 0.005 37.45 ANTER0OM SUPPORT Ss*830801 007101 C20H005 RB SUPP-0UTSIDE CTMT 5 HP 0.000 5.72 ANTEROOM SUPPORT 8 830801 007102 C90K001 RB DATA ACQUISITION 4 CN 0.742 6.57 COREBORE 4 IN. HOLE / CUT RCDT VENT LINE $830801 007102 C90K001 RB DATA ACQUISITION 1 HP 0.109 1.70 COREBORE 4 IN. HOLE / CUT RCDT VENT LINE 830803 007117 C90K001 RB DATA ACQUISITION 2 IC 0.033 0.85 RECONNECT 7 INCORE INSTRUMENT CABLES 830803 007119 C20H005 RB SUPP-0UTSIDE CTMT 27 CN 0.002 70.20 ANTER0OM SUPPORT

  • 830803 007119 C20H005 RB SUPP-OUTSIDE CTMT 9 HP 0.000 38.22 ANTEROOM SUPPORT
  • 830803 007119 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.005 2.13 ANTEROOM SUPPORT
  • 830803 007119 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.68 ANTER0OM AUPPORT 830805 007132 C90K001 RB DATA ACQUISITION 2 CN 0.303 3.15 COREBORE/CtMERA INSPECTION - 305* LEVEL 830805 007133 C20H001 78 SUPPORT ACTIVITY 2 CN 0.109 1.93 CHANGE BREAKERS ON POWER BUGGY 830808 007147 C20H005 RB SUPP-0UTSIDE CTMT 95 CN 0.083 208.62 ANTER0OM SUPPCRT
  • t30808 007147 C20H005 RB SUPP-0UTSIDE CTMT 31 HP 0.010 148.16 ANIER00M SUPPORT
  • t30808 007147 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.001 8.07 ANTEROOM SUPPOR T
  • 830808 007147 C20H005 RB SUPP-OUTSIDE CTMT 1 RP 0.000 1.35 ANTEROOM SUPPORT
  • 830808 007147 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.000 0.77 ANTER0OM SUPPORT 830808 007148 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.006 2.28 EQUIPMENT AIRLOCK SUPPORT 830808 007149 C20H005 RB SUPP-0UTSIDE CTMT 21 CN 0.178 40.65 PERSONNEL AIRLOCK SUPPORT 830808 007161 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.008 13.30 OPERATE NLB PUMP 830809 007167 C20H001 RB SUPPORT ACTIVITY 2 OP 0.228 3.43 CONTAMINATION CCf' TROL-RVHS$ &

'D' RINGS

  • 830809 007167 C20H001 RB SUPPORT ACTIVITY 1 UM 0.145 1.72 CONTAMINA~. ION CONTROL-RVHSS &

'D' RINGS

  • 830809 007167 C20H001 RB SUPPORT ACTIVITY 1 CM 0.171 1,63 CONTAMINATION CONTROL-RVHSS &

'D' RINGS 830809 007169 C20H001 RB SUPPORT ACTIVITY 1 AM 0.167 1.48 DECON INSPECTION 8830809 007169 C20H001 RB SUPPORT ACTIVITY 1 CN 0.137 1.48 DECON INSPECTION 830811 007184 C80N001 RB WASTE REMOVAL 2 RP 0.446 3.50 REMOVE NEUTRON SHIELD TANKS 830811 007185 C30D001 RB DECON-282* ELEV 2 OP 0.179 3.12 FLUSH CORE INSTRUMENT AREA

  • 830811 007185 C300001 RB DECON-282' ELEV 1 UM 0.090 1.70 FLUSH CORE INSTRUMENT AREA
  • 830811 007185 C30D001 RB DECON-282* ELEV 2 CH 0.125 2.60 FLUSH CORE I NS T R UME N T AREA
  • 830811 007185 C30D001 RB DECON-282' ELEV 2 IC 0.201 3.50 FLUSH CORE INSTRUMENT AREA l

DATE 052286 PAGE 40 PNO. 39 RID 24 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • 830811 007185 C30D001 RB DECON-282' ELEV 2 MM 0.142 3.10.

................T. ION _ HOUR TASK DESCRIP

  • DATE AC ENTR. CODE.... R E M............S.._.......
  • .......NUMBE.R. NUMBER................... T..I V I T Y FLUSH CORE INSTRUMENT AREA 830811 007190 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.002 0.55 CHECK EQUIPMENT IN HOT SHOP 830811 007191 C80N001 RB WASTE REMOVAL 1 IC 0.0!!

1,58 REMOVE NEUTRON SHIELD TANKS $830811 007191 C80N001 RB WASTE REMOVAL 1 UM 0.006 1.57 REMOVE NEUIRON SHIELD TANKS 830812 007198 C90K001 RB DATA ACQUISITION 2 CN 0.161 3.45 INSTALL SAMPLE LINE-SUMP PUMP DISCHARGE 830812 007201 C20H001 RB SUPPORT ACTIVITY 1 CN 0.263 3.48 INSTALL HOSES AND MANIFOLD-347' LEVEL

  • 830812 007201 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.85 INST ALL HOSE S AND MANIF OLD-3 47 ' LEVEL 830812 007202 C20H001 RB SUPPORT ACTIVITY 2 CN 0.421 2.77 INSTALL AIR HOSES & MANIFOLD-305' LEVEL 830812 007204 C20H006 RB SAFETY INSPECTION 4 CN 0.144 2.97 INSTALL HATCH COVERS 830815 007214 C30M001 DECON SERVICE STRUCT 1 OP 0.045 1.03 NEUTRON SHIELD TANK REMOVAL
  • 830815 007214 C30M001 DECON SERVICE STRUCT 1 HP 0.020 0.68 NEUTRON SHIELD TANK REMOVAL

'*830815 007214 C30M001 DECON SERVICE STRUCT 1 RP 0.040 1.02 NEUTRON SHIELD TANK REMOVAL 830815 007217 C90K001 RB DATA ACQUISITION 1 CN 0.055 0.70 INSPECT SSTR NEUTRON DOSIMETER AREA 830815 007219 C30M001 DECON SERVICE STRUCT 2 IC 0.017 3.58 NEUTRON SHIELD TANK REMOVAL

  • 830815 007219 C30M001 DECON SERVICE STRUCT 2 UM 0.017 3.58 NEUTRON SHIELD TANK REMOVAL 830815 007220 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.056 8.43 EQUIPMENT AIRLOCK SUPPORT 830815 007221 C20H005 R f! SUPP-0UTSIDE CYMT 66 CN 0.011 168.23 ANTE R0OM SUPPORT
  • 830815 007221 C20H005 RB SUPP-0UTSIDE CIMT 18 HP 0.015 82.07 ANTEROOM SUPPORT
  • 830815 007221 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.005 3.80 ANTEROOM SUPPORT 830816 007240 C20H001 RB SUPPORT ACTIVITY 4 CN 0.591 7.73 SET UP TEMPORARY STORAGE AREA-347' LEVEL
  • 830816 007240 C20H001 RB SUPPORT ACTIVITY I EL 0.154 2.25 SET UP TEMPORARY STORAGE AREA-347' LEVEL 830816 007242 C80N001 RB WASTE REMOVAL 2 OP 0.325 3.13 REMOVE NE U T RON SHIELD TANKS
  • 830816 007242 C80N001 RB WASTE REMOVAL I RP 0.233 1.87 PE MOVE NEUIRON SHIELD TANKS 830819 007263 C50H001 RB P.M.

AND SURVEY 2 CN 0.031 0.83 PLACE CABINE TS F OR COMBUSTIBLE-LIQUID 830819 007264 C20H001 RB SUPPORT ACTIVITY 4 CN 0.192 4.28 SET UP TEMPORARY STORAGE AREA-347' LEVEL 830819 007267 C80N001 RB WASTE REMOVAL 1 OP 0.126 1.27 REMOVE NEUTRON SHIE LD TANKS U1 *830819 007267 C80N001 RB WASTE REMOVAL 2 RP 0.185 2.58 REMOVE NEUTRON SHIELD TANKS on 830822 007276 C20H006 RB SAFE TY INSPECTION 1 AM 0.057 1.18 SAFETY INSPECTION-ALL LEVELS

  • 830822 007276 C20H006 RB SAFETY INSPECTION 1 HP 0.089 1.27 SAFETY INSPECTION-ALL LEVELS
  • 830822 007276 C20H006 RB SAFETY INSPECTION 1 CN 0.107 1.23 SAFETY INSPECTION-ALL LEVELS 830822 007279 C20H002 RB - CCTV 2 CN 0.632 5.53 RELOCATE TV CAMERAS 2, 3&5 830822 007286 C20H005 RB SUPP-0UTSIDE CTMT 52 CN 0.043 145.65 ANTEROOM SUPPORT
  • 8308?? 007286 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.014 71.87 ANTER0OM SUPPORT
  • 830822 007286 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 2.75 ANTEROOM SUPPORT
  • 830822 007286 C20H005 RB SUPP-0UTSIDE CTMT 3 RP O.020 15.88 ANTEROOM SUPPORT
  • 830822 007286 C20H005 RB SUPP-0UTSIDE CTMT 4 RC 0.030 17.65 ANTE ROOM SUPPORT 830822 007287 C80N001 RB WASTE REMOVAL 3 OP 0.000 0.33 REMOVE NEUTRON SHIELD TANKS
  • 830822 007287 C80N001 RB WASTE REMOVAL 1 HP 0.005 1.33 REMOVE NEUIRON SHIELD TANKS
  • 830822 007287 C80N001 RB WASTE REMOVAL 2 RP 0.000 3.07 REM 0kt NEUIRON SHIELD TANKS
  • 830822 007287 C80N001 RB WASTE REMOVAL 1 MM 0.000 0.87 REMOVE NEUTRON SHIELD TANKS 830822 007288 C20H005 RB SUPP-OUTSIDE CTMT 14 CN 0,130 26.67 PERSONNE L & E CUIPME NT AIR LOCK SUPPORT
  • 830822 007288 C20H005 RB SUPP-0UISIDE CTMT 1 OP 0.020 2.78 PE RSONNE L & EQUIPME NT AIR LOCK SUPPOR T
  • 830822 007288 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.018 2.78 PERSONNEL & EQUIPMENT AIRLOCK SUPPORT 830822 007296 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 0.35 OPERATE NLB PUMP 830823 007299 C20H001 RB SUPPORT ACTIVITY 2 RP 0.212 2.05 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 RW 0.047 1.18 CONIAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 UM 0.066 1.52 CONTAMINATION CONTROL ACTIV!ilES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 CM 0.061 1.05 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 FN 0.094 1.42 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 HP 0.076 0.93 CONTAMINATION CONTROL ACTIVITIES

l l DATE 052286 PAGE 41 PNO. 40 RID 24 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE..,NUMBE.R. NUMBER.,...................IVIT.Y.................E.NTR..... CODE. P.E M......HOURS.................SK DESCRIPTION ACT TA

........ 0.142 2.48 CONTAMINATION CONTROL ACTIVITIES

  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 2 CN 830826 007320 C20H002 RB - CCTV 2 CN 0.778 4.30 RELOCATE TV CAMERAS 2 & 3 830826 007322 C80N001 RB WASTE REMOVAL 2 OP 0.108 2.85 REMOVE NEUTRON SHIELD TANKS

$830826 007322 C80N001 RB WASTE REMOVAL 2 RP 0.098 2.80 REMOVE NEUTRON SHIELD TANKS

  • 830826 007322 C80N001 RB WASTE REMOVAL 1 MM 0.005 1.43 REMOVE NEUTRON SHIELD TANKS 830826 007325 C20H001 RB SUPPORT ACTIVITY 3 CN 0.172 1,60 RE PL ACE F liTINGS ON AIR HEADERS 830826 007327 C20H002 RB - CCTV 2 CN 0.136 2.18 INSTALL SCAFFOLD FOR CAMERA 1 830826 007332 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 1.13 STAGE EQUIPMENT AT HATCH AIRLOCK

$830826 007332 C20H005 RB SUPP-0UTSIDE CIMT 1 CM 0,000 1.13 STAGE EQUIPMENT AT HATCH AIRLOCK 830829 007334 C70H001 RB RAD SURVEYS 5 HP 0.553 7.38 HP SURVE YS/ JOB COVERAGE 830829 007335 C80N001 RB WASTE REMOVAL 1 OP 0.005 0.83 HIGH RAD TRASH REMOVAL

  • 830829 007335 C80N001 RB WASTE REMOVAL 1 HW 0.025 0.82 HIGH RAD TRASH REMOVAL
  • 830829 007335 C80N001 RB WASTE REMOVAL 1 UM 0.015 0.82 HIGH RAD TRASH REMOVAL 830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 58 CN 0.024 167.28 RB ENTRY SUPPORT - ALL AREAS
  • 830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.008 89.12 RB ENTRY SUPPORT - ALL AREtS

$830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 4.80 RB ENTRY SUPPORT - ALL AREAS

  • 830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 2.82 RB ENTRY SUPPORT - ALL AREAS
  • 830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 1.20 RB ENTRY SUPPORT - All AREAS 830829 007341 C20H005 RB SUPP-0UTSIDE CTHT 15 CN 0.122 26.02 PERSONNEL & EQUIP AIRLOCKS SUPPORT 830829 007353 C80N001 RB WASTE REMOVAL 1 OP 0.005 1.23 HIGH RAD TRASH REMOVAL
  • 830829 007353 C80N001 RB WASTE REMOVAL 1 UM 0.005 1.17 HIGH RAD TRASH REMOVAL 830829 007356 C20H002
  • B - CCTV 2 CN 0.205 3.53 RELOCATE TV CAMERAS 2. 3&5 830830 007354 C35N005 DOSE REDUCTION-RVHSS 4 CN 0.299 5.12 REMOVE SCAFFOLD FROM REFUELING CANAL 830830 007355 C20H006 RB SAF ETY INSPECTION 2 CN 0.264 3.45 SAFETY INSPECTION-ALL LEVELS 830830 007357 C20H001 RB SUPPORT ACTIVITY 3 CN 0.197 4.03 INSTALL TOOL BOX AND CASTER FRAME
  • 830830 007357 C20H001 Rd SUPPORT ACTIVITY I MM 0.053 1,47 INSTALL TOOL BOX AND CASTER FRAME un 830901 007380 C20H003 RB RADI& SYSTEM 3 CN 0.355 6.15 REPAIR MOTOROLA ANTENNA cn 830902 007378 C20H002 RB - CCTV 2 CN 0.318 4.88 RELOCATE TV CAMERA 1 AND ANTENNA I

830902 007382 C35N005 DOSE REDUCTION-RVHSS 4 CN 0.770 10.18 REMOVE SCAFFOLD FROM REFUELING CANAL

  • 830902 007382 C35P005 DOSE REDUCTION-RvHSS 1 ovi 0.131 2.53 REMOVE SCAFFOLD FROM REFUELING CANAL 830906 007391 C20h003 RB RADIO SYSTEM 2 CN 0.329 2.60 RELOCATE ANTENNA 830906 007395 C20H004 RB SPIDER 3 CN 0.255 5.26 GENERAL MAINT - P.C.

TROLLEY SPIDER 830906 007406 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.125 35.75 PERSONNEL & EQUIP AIRLOCKS SUPPORT 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 76 CN 0.055 199.99 ANTEROOM SUPPORT $830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 19 HP 0.005 123.25 ANTEROOM SUPPORT

  • 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 2.18 ANTEROOM SUPPORT
  • 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.003 1.73 ANTEROOM SUPPORT

$830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.000 1.08 ANTEROOM SUPPORT 830906 007413 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.008 4.00 REPAIR DAMAGED NUC INST COVER PLATE 830907 007415 C20H001 RB SUPPORT ACTIVITY 3 CN 0.188 3.25 MAINTAIN VACUUM FILTERS AND HOSES

  • 830907 007415 C20H001 RB SUPPORT ACTIVITY 1 HP 0.012 0.58 MAIN T AIN VACUUM F IL TE R S AND HOSES 830907 007418 C20H001 RB SUPPORT ACTIVITY 4 RP 0.103 3.27 REMOVE TOPOGRAPHY EQUIPMENT 830908 007423 C80N001 RB WASTE REMOVAL 4 RP 0.230 6.26 STAGE MIRROR INSULATION / TRASH REMOVAL
  • 830908 007423 C80N001 RB WASTE REMOVAL 1 HP 0.075 1.67 STAGE MIRROR INSULATION / TRASH REMOVAL 830909 007440 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.000 4.13 PRESSURE DECAY TEST FOR SERVICE AIR 830912 007448 C80N001 RB WASTE REMOVAL 2 RP C.185 2.35 STAGE MIRROR INSULATION / CUT CONDUIT 830912 007449 C20H001 RB SUPPORT ACTIVITY 2 CN 0.069 1.73 INSTALL ROLLER GEDS AND LUBRICATE 830912 007451 C90K001 RB DATA ACQUISITION 2 OP 0.251 2.83 OBTAIN SUMP SAMPLE
  • 830912 007451 C90K001 RB DATA ACQUISITION 2 HP C.247 2.88 OBTAIN SUMP SAMPLE
  • 830912 007451 C90K001 RB DATA ACQUISITION 2 CM 0.174 2.90 OBTAIN SUMP SAMPLE

DATE 022486 PAGE 42 PNO. 41 .TMI-2 UNC DDS - ACTIVITY REPOR7-REACTOR OUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. ATE.. NUMBER. NUMBER ACTIVITY EN1R. C OD E.... R E.M

. HOURS TASK DESCRIPTION ......c............................................, 830912 007453 CbH005.RB SUPP-0UTSIDE C'MT 18 CN 0.175 33.97 PERSONNEL & EQUIF. AIRLOCKS SUPPORT 830912 007454 C20H005 RB SUPP-OUTSIDE C'.4T 59 CN 0.037 164.40 ANTER0OM SUPPORT

  • 830912 007454 C20H005 RB SUPP-0UTSIDE C1ti 16 HP 0.028 87.50 ANTEROOM SUPPORT
  • 830912 007454 C20H005 RB SUPP-0UISIDE CTMT 1 RP 0.000 0 if ANTERDOM SUPPORT 830913 007473 C20H001 RB SUPPORT ACTIVIT) 4 CN 0.439 7.73 IDENTIFY & LABEL TEMP CABLES-ELEVATOR 830913 007474 C80N001 RB WASTE REMOVAL 5 RP 0.668 8.85 REMOVE MIRROR INSULATION FROM RB
  • 830913 007474 C80N001 RB WASTE REMOVAL 2 IC 0.125 3.85 REMOVE MIRROR INSULATION FROM RB
  • 830913 C07474 C80N001 RB WASTE REMOVAL 2 CM 0.068 4.40 REMOVE MIRROR INSULSTION F ROM RB 830913 007479 C20H005 RB SUPP-0UTSIDE CTMT 36 IC 0 036 134.95 DECON ENTRY SUPPORT EQUIPMENT
  • 830913 007479 C20H005 RB SUPP-0UTSIDE CTMT 2 HP 0.000 9.12 DECON ENTRY SUPPORT EQUIPMENT
  • 830913 007479 C20H005 RB SUPP-OUTSIDE CTMT 2 CN 0.000 3.95 DECON ENTRY SUPPORT EQUIPMENT 830914 007485 C90K001 RB DATA ACQUISITION 2 IC 0.138 2.57 UNDERHEAD VIDEO INSPECTION
  • 830914 007485 C90K001 RB DATA ACQUISITION 1 HP 0.178 3.50 UNDERHEAD VIDEO INSPECTION
  • 830914 007485 C90K001 RB DalA ACQUISITION 1 RP 0.272 3.47 UNDERHEAD VIDEO INSPECTION
  • 830914 007485 C90K001 Re DATA ACQUISITION 1 CN 0.149 3.45 UNDERHEAD VIDEO INSPECTION 830919 007505 C20H005 RB SUPP-0UTSIDE CTMT 94 CN 0.035 253.47 ANTEROOM SUPPORT
  • 830919 007505 C20N005 RB SUPP-0UTSIDE CTMT 22 HP 0.010 117.90 ANTEROOM SUPPORT
  • 830919 007505 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 1.00 ANTEROOM SUPPORT
  • 830919 007505 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.005 2.25 ANTEROOM SUPPORT 830919 007506 C20H005 RB SUPP-0UTSIDE CTMT 20 CN 0.212 38.15 RB ENTRY SUP? ORT-PERSONNEL & EQUIP ARLKS
  • *830919 007506 C20H005 RG SUPP-0UTSIDE CTMT 1 OP 0.000-0 02 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 8

RB SUPPORT ACTIVITY 1 AM 0.141 1.90 SAFETY & HOUSEKEEPING INSPECT OF D RINGS 7 **830920 007524 C20H001 830920 007524 C20H007

  • c SUPPORT ACTIVITY 1 CN 0.158 2.10 SAFETY & HOUSEKEEPING INSPECT OF D RINGS 830920 007524 C20H00.

Rb SUPPORT ACTIVITY 1 RP 0.110 2.10 SAFETY & HOUSEMEEPING INSPECT OF D RINGS 830920 007525 C90K001 4 DATA ACQUISITION 3 IC 0.455 6.35 VIDEO SURVEY OF 282' FROM 305* LEVEL

  • 830920 007525 C90K001 6%TA ACQUISITION 1 CN 0.425 2.07 VIDEO SURVEY OF 282* FROM 305* LEVEL 830920 007526 C90K001 Ar J 1A ACQUISITION 1 OP 0.099 0.97 OBTA1N SUMP SAMPLE
  • $30920 007526 C90K001 98 DA's ACQUISITION 1 HP 0.248 2.03 OBTAIN SUMP SAMPLE
  • $30920 007526 C90K00'

~' DAfr ACQUISITION 1 CN 0.099 0.80 OBTAIN SUMP SAMPLE 830920 007536 C20H00t N, -LtJTSIDE CTMT 2 HP 0.005 4.18 DECGN & TEST CCTV EQUIPMENT

  • 830920 007536 C20H0C0

..,ve? CUTSIDE CTMT 4 IC 0.010 21 45 DECON & TEST CCTV EQUIPMENT 830921 007531 C90K001 RB DATA ACQUISITION 8 CN 1.216 15.92 COR. BOP.F SAMPL ING 830921 007532 C80N001 RB WASTE REMOVAL 3 OP 0.058 2.08 HIGH RAD (RASH REMOVAL 830921 007533 C20H001 RB SUPPORT ACTIVITY 4 CN 0.627 6.95 IDENTIF Y AND LABE L TEMPORARY CABLES 830921 007534 C90K001 RB DATA ACQUISITION 2 CN 0.689 5.17 SAMPLE PAINT COALING 830922 007541 C20H001 RB SUPPORT ACTIVITY 1 RP 0.097 1.72 CLEAN UP SERVICE STRUCTURE

  • 830922 007541 C20H001 RB SUPPORT ACTIVITY 1 CN 0.058 1.72 CLEAN UP SERVICE STRUCTURE 830922 007542 C90K001 RB DATA ACQUISITION 1 OP 0.428 2.40 SUMP SAMPLES
  • 830922 007542 C90K001 RB DATA ACQUISITION 1 HP 0.231 2.43 SUMP SAMPLES
  • 830922 007542 C90K001 RB DATA ACQUISITION 1 CM 0.197 2.43 SU'1P SAMPLES 830922 007545 C80N001 RB WASTE REMOVAL 2 OP 0.011 3.12 LOW RAD TRA W REMOVAL
  • 830922 007545 C80N001 RB WASTE REMOVAL c2 EL 0.272 3.55 LOW RAD trash REMOVAL
  • 830922 007545 C80N001 RB WASTE REMOVAL 1 IC 0.012 0.93 LOW RAD TRASH REMOVAL
  • 830922 007545 C80N001 RB WASTE REMOVAL 2 CM 0.209 3.47 LOW RAD TRASH PEMOVAL 83092G 007560 C20H005 RB SUPP-0UTSIDE CTMT 40 LN 0.013 108.84 ANTEROOM SUPPORT
  • 830926 007560 C20H005 RB SUPP-0UTSIDE CTMT 11 HP 0.020 50.82 ANTEROOM SUPPORT
    • 30926 007560 C20H005 RB SUPP-0UTSIDE CTMT 1 RW 0.005 2.12 ANTEROOM SUPPORT
  • 830926 007560 C20n005 RB SUPP-0UTSIDE CTMT 1 MD 0.005 2.10 ANTEROOM SUPPORT
  • S30926 007560 L20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 1.12 ANTEROOM SUPPORT

,830926 007561 C20H005 -RB SUPP-0UTSIDE CTMT 9 CN 0.086 16.58 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS

DATE 022486 PAGE 43 PNO. 42 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 236 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS, TIME . HOUl: S TASK DESCRIPTION ACT ENTR. CODE. R E.M

  • D. ATE... NUMBER. NUMBER....................IVITY...............................................................................................

a 830926 007562 C20H001 RB SUPPORT ACTIVITY 2 CN 0.362 3 40 IDENTIFY AND LABEL CABLES 830926 007563 C80N001 RB WASTE REMOVAL 2 RP 0.128 2 70 REMOVE MIRROR INSULATION FROM RB

  • 830926 007563 C80N001 RB WASTE REMOVAL 1 EL 0.100 1 47 REMOVE MIRROR INSULATION FROM RB
  • S30926 007563 C80N001 RB WASTE REMOVAL 1 IC 0.025 1 30 REMOVE MIRROR INSULATION FROM RB 830926 007564 C90h001 RB DATA ACQUISITION 5 CN 1.097 8 15 CORE BORE SAMPLES 830926 007565 C70H001 RB RAD SURVEYS 7 HP 0.900 10 93 HP SURVEYS / JOB COVERAGE 830929 007607 C20H005 RB SUPP-0UTSIDE CTMT 8 IC O.005 40 97 DECON & TEST CCTV EQUIPMENT 830930 007601 C80N001 RB WASTE REMOVAL 2 CN 0.329 3 11 CUT UP ROLLER BED ASSEMBLIES 830930 007602 C90K001 RB DATA ACQUISITION 1 IC 0.105 2 10 VIDEO SURVEY OF 282* LEVEL
  • 830930 007602 C90K001 RB DATA ACQUISITION 1 CN 0.132 2 08 VIDEO SURVEY OF 282* LEVEL 830930 007603 C20H001 RB SUPPORT ACTIVITY 2 CN 0.227 3 78 IDENTIFY AND LAGEL CABLES 830930 007604 c50H001 RB P.M.

AND SURVEY 2 CN 0.520 4 77 PHOTO SURVEY & CLE ANING - ALL LEVELS 831003 007672 C70H001 RB RAD SURVEYS 1 CN 0.117 1 35 HP SURVEYS / JOB COVERAGE $831003 007672 C70H001 RB RAD SURVEYS 1 HP 0.248 2 13 HP SURVEYS / JOB COVERAGE 831003 007673 C35N002 DOSE REDUCTION-347' 5 CN 0.376 6 23 CLEAN & REMOVE STRIP COAT IN TEST AREA

  • 831003 007673 C35N002 DOSE REDUCTION-347' 1 NP 0.079 1 78 CLEAN & REMOVE STRIP COAT IN TEST AREA 831003 007676 C90K001 RB DATA ACQUISITION 4 CN 0.489 5 63 REPAIR CORE BORE HOLES 831003 007678 C20H001 RB SUPPORT ACTIVITY 2 OP 0.244 3 33 CONTAINMENT CLEANUP - ALL ELEVATIONS
  • 831003 007678 C20H001 RB SUPPORT ACTIVITY 1 EL 0.112 1 67 CONTAINMENT CLEANUP - ALL ELEVATIONS
  • 831003 007678 C20H001 RB SUPPORT ACTIVITY 2 IC 0.353 3 87 CONT AINMENT CLE ANUP - ALL ELEVATIONS e *831003 007678 C20H001 RS SUPPORT ACTIVITY 1 UM 0.174 1 78 CONTAINMENT CLEANUP - ALL ELEVATIONS U1 *831003 007678 C20H001 RB SUPPORT ACTIVITY 2 CN 0.346 3 83 CONTAINMENT CLEANUP - ALL ELEVATIONS CO 831003 007688 C20H005 RS SUPP-0UTSIDE CTMT 10 CN 0.077 17.28 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831003 007689 C20H005 RB SUPP-0UTSIDE CTMT 66 CN 0.054 116 80 ANTEROOM SUPPORT
  • 831003 007689 C20H005 RB SUPP-0UTSTDE CTMT 10 HP 0.014 37.88 ANTEROOM SUPPORT
  • 831003 007689 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 3.47 ANTER0OM SUPPORT
  • S31003 007689 C20H005 RB SUPP-0UTSIDE CTMT 2 RC 0.013 14.78 ANTER0OM SUPPORT 831005 007702 C80N001 RB WASTE REMOVAL 1 UM 0.018 1.13 LOW RAD TRASH REMOVAL / SUMP SAMPLE
  • 831005 007702 C80N001 RB WASTE REMOVAL 1 EL 0.031 1.15 LOW RAD TRASH REMOVAL / SUMP SAMPLE
  • 831005 007702 C80N001 RB WASTE REMOVAL 1 CN 0.087 1.32 LOW RAD TRASH REMOVAL / SUMP AAMPLE 831005 007703 C300001 RB DECON-282' ELEV 3 OP 0.278 2 88 PUMP & FLUSH ELEVATOR PIT

$831005 007703 C30D001 RB DECON-282* ELEV 2 IC 0.317 2.07 PUMP & FLUSH ELEVATOR PIT

  • 831005 007703 C30D001 RB DECON-282* ELEV 1 CM 0.175 1 10 PUMP & F LUSH ELEVATOR PIT
  • 831005 007703 C30D001 RB DECON-282' ELEV 1 UM 0.250 1.08 PUMP & FLUSH ELEVATOR PIT
  • 831005 007703 C300001 RB DECON-282' ELEV 2 HP 0.447 2.35 PUMP & FLUSH ELEVATOR PIT 831005 007704 C30F001 DECON RB CANAL 4 CN 0.284 6.62 FLUSH DEEP END Of FUEL CANAL 831005 007705 C80N001 RB WASTE REMOVAL 1 MM 0.005 1.70 LOW RAD TRASH REMOVAL / SUMP SAMPLE
  • 831005 007705 C80N001 RB WASTE REMOVAL 1 RP 0.000 0.55 LOW RAD TRASH REMOVAL / SUMP ASMPLE
  • 831005 007705 C80N001 RB WASTE REMOVAL 1 CM 0.005 1.69 LOW RAD TRASH REMOVAL / SUMP SAMPLE 831007 007718 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.000 7.18 DECON & TEST CCTV EQUIPMENT
  • 831007 007718 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 6.72 DECON & TEST CCTV EQUIPMENT
  • 831007 007718 C20H005 RB SUPP-0UTSIDE CTMT 4 IC 0.001 22.02 DECON & TEST CCTV EQUIPMENT 831010 007720 C20H005 RB SUPP-0UTSIDE CTMT 68 CN 0.022 145.39 ANTEROOM SUPPORT
  • 831010 007720 C20H005 RB SUPP-0UTSIDE CTNT 23 HP 0.007 l'O.33 ANTER0OM SUPPORT 831010 007721 C20H005 RB SUPP-OUTSIDE CTMT 16 CN 0.108 27.17 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS
  • 831010 007721 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 0.33 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831010 007723 C30D001 RB DECON-282* ELEV 2 OP 0.227 3.37 FLUSH ELEVATOR - 323' LEVEL
  • 831010 007723 C30D001 RB DECON-282' ELEV 2 UM 0.350 3.25 F LUSH E LEVATOR - 323' LEVEL
  • 831010 007723 C30D001 RB DECON-282
  • E LEV 2 CM 0.242 3.48 FLUSH E LEVATOR - 323' LEVEL
  • 831010 007723 C30D001 RB DECON-282' ELEV 1 EL 0.133 1.55 FLUSH ELEVATOR - 323* LEVEL l

DATE 022486 PAGE 44

PNO, 43

.TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER,..........................IVITY............

...............HOU.RS ACT ENTR, CODE. REM TASK D. .................E.SC.RIPTION

  • ==..
  • 831010 007723 C30D001 RB DECON-282* ELEV 1 CN 0.103 1,72 FLUSH E1EVATOR - 323' LEVEL 831010 007726 C35N002 DOSE REDUCTION-347' 1 HP 0.240 1.78 SCABBLE TEST AREA AND SAMPLE
  • 831010 007726 C35N002 DOSE REDUCTION-347' 4 CN 0.335 5.27 SCABBLE TEST APEA AND SAMPLE 831014 007763 C80N001 RB WASTE REMOVAL 3 CN 0.254 3.67 SET UP ARE A FOR PLASMA ARC
  • 831014 007763 C80N001 RB WASTE REMOVAL 1 MM 0.059 1.05 SET UP AREA FOR PLASMA ARC 831017 007781 C20H005 RB SUPP-0UTSIDE CTMT 0 CN 0.024 86.24 RB ENTRY SUPPORT
  • S31017 007781 C20H005 RB SUPP-0UTSIDE CTMT 8 HP 0.000 32.08 RB ENTRY SUPPORT
  • 831017 007781 C20H005 RB SUPP-0UTSIDE CTMT 2 AD 0.000 0.90 RB ENTRY SUPPORT 831017 007782 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.030 9.67 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831018 007785 C70H001 RB RAD SURVEYS 1 CN 0.053 0.58 HP SURVEYS / JOB COVERAGE
  • 831018 007785 C70H001 RB RAD SURVEYS 2 HP 0.494 4.02 HP SURVEYS / JOB COVERAGE 831018 007786 C300001 RB DECON-282* ELEV 1 OP 0.097 1.97 FLUSH AND PUMP ELEVATOR PIT
  • 831018 007786 C30D001 RB DECON-282* ELEV 1 UM 0.075 1.95 FLUSH AND PUMP ELEVATOR PIT 831018 007788 C35N002 DOSE REDUCTION-347*

1 HP 0.114 1.38 SCABBLE TEST AREA AND SAMPLE

  • S31018 007788 C35N002 DOSE REDUCTION-347*

2 CN 0.136 2.18 SCABBLE TEST AREA AND SAMPLE 831018 007789 C80N001 RB WASTE REMOVAL 3 RP 0.047 3.77 CORE DEBRIS SAMPLE REMOVAL 831018 007790 C20H001 RB SUPPORT ACTIVITY 1 AD 0.119 2.17 SAFETY AND HOUSEKEEPING INSPECTION

  • 831018 007790 C20H001 RB SUPPORT ACTIVITY 1 CN 0.120 2.13 SAFETY AND HOUSEKEEPING INSPECTION 831024 007806 C80N001 RB WASTE REMOVAL 1 IC 0.000 0.88 LOW RAD TRASH REMOVAL
  • 831024 007806 C80N001 RB WASTE REMOVAL 1 OP 0.033 1.02 LOW RAD-TRASH REMOVAL 8 *831024 007806 C80N001 RB WASTE REMOVAL 1 CM 0.000 0.82 LOW RAD TRASH REMOVAL LM *831024 007806 C80N001 RB WASTE REMOVAL 1 UM 0.021 1.02 LOW RAD TRASH REMOVAL j3 831024 007807 C20H001 RB SUPPORT ACTIVITY I RP 0.060 1.22 CENERAL INSPECTION
  • 831024 007807 C20H001 RB SUPPORT ACTIVITY 1 CN 0.106 1.22 GENERAL INSPECTION 831024 007809 C70H001 RB RAD SURVEYS 3 HP 0.345 3.42 HP SURVEYS / JOB COVERAGE 831024 007812 C20H005 RB SUPP-0UTS1pE CTMT 3 CN 0.017 4.85 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS
  • 831024 007812 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.002 0.50 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831024 007813 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.001 47.72 ANTER0OM SUPPORT
  • 831024 007813 C20H005 RB SUPP-0UTSIDE CTMT 4 HP 0.000 15.32 ANTEROOM SUPPORT 831028 007840 C90K001 RB DATA ACQUISITION 3 CN 0.000 10.13 AUTORADIOGRAPHY SAMPLE MANIPULATIONS 831031 007842 C20H001 RB SUPPORT ACTIVITY 1 IC 0.090 1.80 GENERAL CONTAINMENT CLEANUP
  • 831031 007842 C20H001 RB SUPPORT ACTIVITY 1 UM 0.078 1.67 GENERAL CONTAINMENT CLEANUP
  • 831031 007842 C20H001 RB SUPPORT ACTIVITY 2 CN 0.180 3.80 GENERAL CONTAINMENT CLEANUP 831031 007843 C70H001 RB RAD SURVEYS 2 HP 0.504 6.35 HP SURVEYS / JOB COVERAGE 831031 007844 C80N001 RB WASTE REMOVAL 3 OP 0.484 4.56 LOW RAD TRASH F:MOVAL
  • 831031 007844 C80N001 RB WASTE REMOVAL 1 RP 0.025 1.73 LOW RAD TRASH REMOVAL
  • 831031 007844 C80N001 RB WASTE REMOVAL 1 UM 0.020 1.73 LOW RAD TRASH REMOVAL 831031 007845 C90K001 RB DATA ACQUISITION 1 CA 0.211 1.40 CORE DRILL 4 IN. HOLE IN 305* FLOOR
  • 831031 007845 C90K001 RB DATA ACQUISITION 3 CN 0.545 3.85 CORE DRILL 4 IN. HOLE IN 305* FLOOR 831031 007849 C20H005 RB SUPP-0UTSIDE CTMT 15 CN 0.008 45.77 TRASH REMOVAL-AIRLOCKS & ANTEROOM
  • 831031 007849 C20H005 RB SUPP-0UTSIDE CTMT 4 HP 0.004 20.02 TRASH REMOVAL-AIRLOCKS & ANTEROOM
  • 831031 007849 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.000 2.63 TRASH REMOVAL-AIRLOCKS & ANTEROOM
  • 831031 007849 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.005 4.18 TRASH REMOVAL-AIRLOCKS & ANTEROOM 831031 007850 C20H005 PB SUPP-0UTSIDE CTMT 4 CN 0.043 7.58 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831107 007879 C70H001 RB RAD SURVEYS 3 HP 0.596 5.20 HP SURVEYS / JOB COVERAGE 2831107 007879 C70H001 RB RAD SURVE YS 1 CN 0.056 0.67 HP SURVE YS/ JOB COVERAGE 831107 007881 C20H006 RB SAFETY INSPECTION 2 CN 0.130 2.53 NRC INSPECTION
  • 831107 007881 C20H006 RB SAFETY INSPECTION 1 AM 0.075 1.23 NRC INSPECTION
  • 831107 007881 C20H006 RB SAFETY INSPECTION 1 HP 0.070 1.45 NRC INSPECTION 831107 007883 C90K001 RB DATA ACQUISITION 1 HP 0.070 0.73 CORE BORE 4 IN. HOLES-305* ELEV

DATE 022486 PAGE 45 PNO. 44 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK, PERS. DEPT. EXPOS. TIME . CODE ,R.....H.OURS.....,........... TASK DESCRIP. TION

  • DATE.,NUMBE.R. NUMBER....................................

ACTIVITY , ENTR........E.M . 11.63 CORE BORE 4 IN-HOLES-305' ELEV g..... . 1.081

  • 831107 007883 C90K001 RB DATA ACQUISITION 4 CN 831107 007894 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.008 24.20 ANTEROOM SUPPORT
  • 831107 007894 C20H005 RB SUPP-OUTSIDE CTMT 6 HP 0.005 30.82 ANTEROOM SUPPORT
  • S31107 007894 C20H005 RB SUPP-0UISIDE CTMT 2 OP 0.002 3.60 ANTEROOM SUPPORT
  • S31107 007894 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.001 6.70 ANTEROOM SUPPORT 831107 007895 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.032 7.55 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831108 007905 C90K001 RB DATA ACQUISITION 11 CN 0.029 25.17 SECTION CORE SAMPLES FOR ANALYSIS 831110 007915 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.003 4.03 SUPPORT WORK AT PENETRATION 534
  • 831110 007915 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.020 1.57 SUPPORT WORK AT PENEIRATION 534 831112 007922 C90K001 RB DATA ACQUISITION 5 CN 0.000 11.32 CORE SAMPLE EXPERIMENT 831114 007918 C70H001 RB RAD SURVEYS 4 HP 0.131 2.58 HP SURVEYS / JOB COVERAGE 831114 007920 C50H001 RB P.M.

AND SURVEY 2 IC 0.545 5.38 SMOKE TEST FIRE DETECTORS - 'D' RINGS 831114 007921 C90K001 RB DATA ACQUISITION 1 EL 0.093 1,72 REMOVE JIB CRANE CONTROL PENDANT & CABLE

  • 831114 007921 C90K001 RB DATA ACQUISITION 4 CN 0.316 6.53 REMOVE JIB CR ANE CONTROL PENDANT & CABLE

$831114 007921 C90K001 RB DATA ACQUISITION 1 HP 0.055 1.35 REMOVE JIB CRANE CONTROL PENDANT & CABLE 831114 007924 C20H005 RB SUPP-0VTSIDE CTMT 3 CN 0.019 5.05 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831114 007925 C20H005 RB $UPP-0UTSIDE CTMT 12 CN 0.003 20.15 ANTEROOM SUPPORT

  • 831114 007925 C20H005 RB SUPP-0UTSIDE CTMT 2 HP 0.000 11.98 ANTEROOM SUPPORT
  • 831114 007925 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.002 0.77 ANTER0OM SUPPORT
  • S31114 007925 C20H005 RB SUPP-0UTSIDE CTMT 2 RC 0.000 8.58 ANTER0OM SUPPORT

$n 831114 007958 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.002 24.03 ANTEROOM SUPPORT C3 *831114 007958 C20H005 RB SUPP-0UTSIDE CTMT 8 HP 0.000 23.17 ANTER0OM SUPPORT

  • 831114 007958 C20H005 RB SUPP-OUTSIDE CTMT 2 OP 0.000 1.23 ANTER0OM SUPPORT 831121 007954 C20H001 RB SUPPORT ACTIVITY 3 CN 0.400 5.92 SAFETY AND HOUSEKEEPING INSPECTION
  • 831121 007954 C20H001 RB SUPPORT ACTIVITY 1 EL 0.039 0.58 SAFETY AND HOUSEKEEPING INSPECTION 831121 007956 C70H001 RB RAD SURVEYS 4 HP 0.819 7.15 HP SURVEYS / JOB COVERAGE 831121 007957 C90K001 RB DATA ACQUISITION 2 CN 0.556 6.15 CUT HOLE IN RCDT VENT LINE FOR SAMPLE 831121 007959 C20H005 RB SUPP-0UTSIDE CTMT 3 CN 0.021 4.83 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831128 007987 C70H001 RB RAD SURVEYS 1 HP 0.029 0.83 HP SURVEYS / JOB COVERAGE 831128 007994 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.001 13.21 RB ENTRY SUPPORT
  • 831128 007994 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.000 7.63 RB ENTRY SUPPORT
  • 831128 007994 C20H005 RB SUPP-OUTSIDE CTMT 2 OP 0.000 1.38 RB ENTRY SUPPORT
  • 831128 007994 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.000 1.60 RB ENTRY SUPPORT 831128 007995 C20H005 RB SUPPe00TSIDE CTMT 1 CN O.005 1.22 RB ENTRY SUPPORT 831205 008026 C70H001 RB RAD SURVEYS 1 CN 0.017 0.33 HP SURVEYS / JOB COVERAGE 831205 008027 C90K001 RB DATA ACQUISITION 1 HP 0.218 4.22 RCDT VIDEO SURVEY / LIQUID SAMPLES
  • 831205 008027 C90K001 RB DATA ACQUISITION 2 IC 0.754 8.32 RCDT VIDEO SURVEY / LIQUID SAMPLES 831205 008029 C90K001 RB DATA ACQUISITION 2 CN 0.093 1.45 DATA ACQUISITION ACTIVITIES-305' & 347'
  • 831205 008029 C90K001 RB DATA ACQUISITION 1 HP 0.074 0.88 DATA ACQUISITION ACTIVITIES-305 & 347' 831205 008031 C80N001 RB WASTE REMOVAL 1 RP 0.091 1.10 SURVEY OF RB FOR WASTE MANAGEMENT
  • 831205 008031 C80N001 RB WASTE REMOVAL 1 CN 0.090 1.10 SURVEY OF RB FOR WASTE MANAGEMENT 831205 008032 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.033 7.33 RB ENTRY SUPPORT 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 3.27 ANTEROOM SUPPORT
  • 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.000 40.37 ANTER0OM SUPPORT
  • 831205 008033 C20H005 RB $UPP-0UTSIDE CTMT 1 RC 0.005 7.15 ANTEROOM SUPPORT
  • 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.35 ANTER0OM SUPPORT
  • 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 1.33 ANTERDOM SUPPORT 831205 008041 C90K001 RB DATA ACQUISITION-3 RP 0.009 4.00 TRANSPORT RCDT AND PLENUM SAMPLES 2831205 008041 C90K001 RB DATA ACQUISITION 1 UM 0.002 1.92 IRANSPORT RCOT AND PLENUM SAMPLE S
  • 831205 008041 C90K001 RB DATA ACQUISITION 2 OP 0.001 1.75 TRANSPORT RCDT AND PLENUM SAMPLES

DATE 022486 PAGE 46 PNO. 45 .TMI-2 UNC: DDS - ACTIVITY REPORT-RE ACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMB
  • ..........ER. NUMBER.....................TIVITY

........................S.....................SCRIPTION AC ENTR. CODE. REM . HOUR TASK DE

  • 831205 008041 C90K001 RB DATA ACQUISITION 1 FU4 0.000 0.53 TRANSPORT RCDT AND PLENUM SAMPLES
  • 831205 008041 C90K001 RB DATA ACOUISITION 1 CN 0.000 3.35 TRANSPORT RCDT AND PLENUM SAMPLES 831205 008048 C45H001 RB CORRECTIVE MAINT 3 MM 0 150 3.88 OPERABILITY CHECK OF AIRLOCK DOORS 831211 008070 C20H005 RB SUPP-0UTSIDE CTMT 1 CN O 000 1.48 CAMERA CHECK 831212 008075 C35N003 DOSE REDUCTION-305' 1 CN O 175 2.48 VERIFY AIR LIFT / REMOVE DECDN EQUIPMENT 831212 008075 C35N003 DOSE. REDUCTION-305' 1 EL 0.104 1.67 VERIFY AIR LIF T/ REMOVE DECON EQUIPMENT
  • 831212 008075 C35N003 DOSE REDUCTION-305' 1 CM 0.300 2,38 VERIFY AIR LIFT / REMOVE DECON EQUIPMENT
  • 831212 008075 C35N003 DOSE REDUCTION-305' I UM 0.078 1.28 VERIF Y AIR LIF T/ REMOVE DECON EQUIPME NT
  • 831212 008075 C35N003 DOSE REDUCTION-305' 1 MM 0.140 2.03 VERIFY AIR LIFT / REMOVE DECON EQUIPMENT 831212 008076 C90K001 RB DATA ACQUISITION 1 HP 0.340 3.93 RCDT VIDEO INSPECTION / SLUDGE SAMPLING
  • 831212 008076 C90K001 RB DATA ACQUISITION 3 IC 1.095 10.85 RCDT VIDEO INSPECTION / SLUDGE SAMPLING 831212 008077 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.009 36.45 RB ENTRY SUPPORT
  • 831212 008077 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.000 16.08 RB ENTRY SUPPORT
  • 831212 008077 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.010 2.65 RB ENTRY SUPPORT 831212 008078 C20H005 RB SUPP-OUTSIDE CTHT 3 CN 0.025 5.43 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831212 008088 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.000 7.65 CAMERA CHECK AND CALIBRATION 831219 008118 C80N001 RB WASTE REMOVAL 2 RP 0.171 2.07 REMOVE TRASH / STAGE MIRROR INSULATION 831219 008120 C45H001 RB CORRECTIVE MAINT 2 CN 0.183 3.47 MODIF Y E LEVATOR SHAFT HATCH COVER 831219 008122 C45H001 RB CORLECTIVE MAINT 1 IC 0.121 2.27 ACTIVATE MAGNETIC SWITCH-AIRLOCK DOORS 831219 008123 C90K001 RB DATA ACQUISITION 2 CM 0.139 1.70 DEST AGE -tE AD SHIE LDING/ POSITION AIRLIF T I *S31219 008123 C90K001 RB DATA ACQUISITION 1 EL 0.056 0.77 DESTAGE LEAD SHIELDING / POSITION AIRLIFT Ch *831219 008123 C90K001 RB DATA ACQUISITION 1 UM 0.065 0.92 DESTAGE LEAD SHIELDING / POSITION AIRLIFT

-d 831219 008126 C20H005 RB SUPP-0UTSIDE CTMT 18 CN 0.017 52.77 RB ENTRY SUPPOR1

  • 8.11219 008126 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 7.25 RB ENTRY SUPPORT
  • 831219 008126 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 1.27 RB ENTRY SUPPORT
  • S31219 008126 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.005 1.23 RB ENTRY SUPPORT
  • 831219 008126 C20H005 RB SUPP-0UTSIDE CTMT 1 QA 0.000 0.63 RB ENTRY SUPPORT 831219 008127 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.031 7.82 RB ENTRY SUPPORT 831227 008155 C50H001 RB P.M.

AND SURVEY 2 OP 0.625 4.52 FIRE DETECTOR OPERATIONAL CHECK 831227 008157 C45H001 RB CORRECTIVE MAINT 1 IC 0.151 1.85 ACTIVATE AND TEST MAGNETIC SWITCH 831227 008170 C20H005 RB SUPP-0UTSIDE CTMT 11 CN 0,019 22.14 ANTER0OM SUPPORT

  • 831227 008170 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.002 3.17 ANTEROOM SUPPORT
  • 831227 008170 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.002 5.52 ANTERDOM SUPPORT 831227 008171 C20H005 RB SUPP-0UTSIDE CTMT 3 CN 0.020 3.72 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 840103 008193 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.000 11.74 RB ENTRY SUPPORT-ANTER0OM
  • 840103 008193 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.020 17.33 RB ENTRY SUPPORT-ANTEROOM 840103 008194 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.010 2.93 RB ENTRY SUPPORT-AIRLOCKS 840103 008195 C70H001 RB RAD SURVEYS 1 HP 0.072 1.02 HP SURVEYS / JOB COVERAGE
  • 840103 008195 C70H001 RB RAD SURVEYS 1 CN 0.033 0.73 HP SURVEYS /3OB COVERAGE 840109 008222 C80N001 RB WASTE REMOVAL 1 CM 0.130 1.40 STAGE EQUIPMENT RACKS - 305* LEVEL
  • 840109 008222 C80N001 RB WASTE REMOVAL 1 OP 0.120 1,42 STAGE EQUIPMENT RACKS - 305' LEVEL 840109 008225 C80N001 RB WASTE REMOVAL 3 CN 0.687 9.92 CUT UP CONST EQUIP USING PLASMA ARC
  • 340109 008225 C80N001 RB WASTE REMOVAL 1 MM 0.150 2.08 CUT UP CONST EOUIP USING PLASMA ARC 840109 008227 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.005 48.57 RB ENTRY SUPPO9T-ALL AREAS
  • 840109 008227 C20H005 EB SUPP-0UTSIDE CTMT 4 HP 0.000 10,4C RB ENTRY SUPPORT-ALL AREAS

$840109 008227 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.40 RB ENTRY SUPPORT-ALL AREAS 840109 008228 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.024 7.40 RB ENTRY SUPPORT-AIRLOCKS 840116 008258 C45H001 RB CORRECTIVE MAINT 1 MM 0.245 3,50 INSTALL FALL PROTECTION OVER AIR COOLERS

  • 840116 008258 C45H001 RB CORRECTIVE MAINT 3 CN 0.830 5.00 INSTALL FALL PROTECTION OVER AIR COOLERS 840116 008261 C70H001 RB RAD SURVEYS 1 RC 0.024 0.58 HP SURVEYS / JOB COVERAGE

DATE 022486 PAGE 47 PNO. 46 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • .... E..,. N UMB E. R. NUMB E R.......................I.TY.................E.N T R

........ HOURS

  • DAT ACTIV

. CODE. REM TASK DE ...........SCRIPTION

  • 840116 008261 C70H001 RB RAD SURVEYS 2 HP 0.095 1.92 HP SURVEYS / JOB COVERAGE
  • 840116 008261 C70H001 RB RAD SURVEYS 1 CN 0.160 3.43 HP SURVEYS / JOB COVERAGE 840116 008263 C20H006 RB SAFETY INSPECTTON 1 AM 0.075 1.37 SAFETY INSPECTION
  • 840116 008263 C20H006 RB SAFETY INSPECTION 1 CN 0.075 1.55 SAFETY INSPECTION 840116 008265 C45H001 RB CCRRECTIVE MAINT 1 IC 0.030 1.38 ADJUST MAGNETIC SWITCH-EOUIPMENT HATCH 840116 008271 C20H005 RB SUPP-0UTSIDE CTM1 4 CN 0.035 9.67 RB ENTRY SUPPORT-AIRLOCKS 840116 008272 C20H005 RS SUPP-0UTSIDE CTMT 29 CN 0.022 88.21 RB ENTRY SUPPORT-ANTER0OM 3840116 008272 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 7.47 RB ENTRY SUPPORT-ANTER0OM
  • 840116 008272 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.005 3.02 RB ENTRY SUPPORT-ANTER0OM 840123 008301 C70H001 RB RAD SURVEVS 1 HP 0.086 1.40 HP SURVE YS/ JOB COVE RAGE 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 22 CN 0.007 74.60 RB ENTRY SUPPORT-ANTER0OM
  • 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.005 17 88 RB ENTRY SUPPOR T-AN T E R 0OM
  • 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.001 2.28 RB ENTRY SUPPOR T-ANTE ROOM
  • 840123 008302 C20H005 RP SUPP-0UTSIDE CTMT 1 UM 0.004 1.28 RB E NTRY SUPPORT-ANTER0OM
  • 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 1.57 RB ENTRY SUPPORT-ANTEROOM 840123 008303 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.053 8.57 RB ENTRY SUPPORT-AIRLOCKS 840123 008307 C50H001 RB P.M.

AND SURVEY 1 CN 0.265 1.95 DECON INSPECTION $840123 008307 C50H001 RB P.M. AND SURVEY 1 MM 0.160 1.83 DECON INSPECTION 840123 008308 C20H001 RB SUPPORT ACTIVITY 1 CN 0.052 1.20 REPLACE SAFETY SWITCH COVER-PEASMA ARC 840123 008310 C80N001 RB WASTE REMOVAL 1 RP 0.017 0.74 STAGE HEAD INSULATION RACKS-305' LEVEL

  • 340123 008310 C80N001 RB WASTE REMOVAL 1 EL 0.014 0.75 STAGE HEAD INSULATION RACKS-305* LEVEL Ch 840130 008347 C70H001 RB RAD SURVEYS 1 CN 0.075 1.82 HP SURVEYS / JOB COVERAGE no 840130 008348 C30D001 RB DECON-282* ELEV 4 CN 0.692 8.47 FLUSH VALVE SFV-104 & SURROUNDING AREA 840130 008352 C80N001 RB WASTE REMOVAL 1 OP 0.054 1.17 SURVEY CONTAINMENT / RAD WASTE INSPECTION
  • 840130 008352 C80N001 RB WASTE REMOVAL 1 RP 0.140 1.95 SURVEY CONTAINMENT / RAD WASTE INSPECTION
  • 840130 008352 C80N001 RB WASTE REMOVAL 1 CN 0.140 1.94 SURVEY CONTAINMENT / RAD WASTE INSPECTION 840130 008356 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.088 19.20 RB ENTRY SUPPORT-AIRLOCKS 840130 008357 C?0H005 RB SUPP-0UTSIDE CTMT 44 CN 0.011 30.52 RB ENTRY SUPPORT-ANTER0OM

$840130 008357 C20H005 RB SUPP-OUTSIDE CTMT 8 HP 0.017 41.58 RB ENTRY SUPPORT-ANTER0OM

  • 840130 008357 C20H005 RB SUPP-0UTSIDE CTMT 2 RW 0.001 2.50 RB ENTRY SUPPORT-ANTEROOM 840201 008374 C45H001 RB CORRECTIVE MAINT 2 CN 0.116 2.05 REPLACE DAMAGED AIR HOSE 840201 008378 C70H001 RB RAD SURVEYS 1 HP 0.049 1.48 HP SURVEYS / JOB COVERAGE 840201 008380 C50H001 RB P.M..AND SURVEY 2 CN 0.000 10.18 CABLE TESTING-PENETRATION 534
  • 840201 008380 C50H001 RB P M.

AND SURVEY 10 IC 0.044 17.32 CABLE TESTING-PENETRATION 534 840206 008393 C70H001 RB RAD SURVEYS 2 HP 0.114 1.38 HP SURVEYS / JOB COVERAGE

  • 840206 008393 C70H001 RB RAD SURVEYS 2 CN 0.134 2.58 HP SURVEYS / JOB COVERAGE 840206 008399 C30A001 DECON POLAR CRANE 4 CN 0.417 8.53 PREPARE PC. FOR LOAD TEST 840206 008400 C80N001 RB WASTE REMOVAL 2 CN 0.209 4.10 CUT AND REMOVE MISCELLANEOUS STEEL 840206 008403 C804001 RB WASTE REMOVAL 2 CN 0.051 0.92 STAGE MISCELLANEOUS STEEL - 305' LEVEL
  • 840206 008403 C80N001 RB WASTE REMOVAL 1 EL 0.158 2.67 STAGE MISCE LLANEOUS STEE L - 305 ' LEVEL
  • 840206 008403 C80N001 RB WASTE REMOVAL 1 MM 0.134 2.62 ST AGE MISCELL ANEOUS STE EL - 305' LEVEL 840206 008404 C20H005 RB SUPP-0UTSIDE CTMT 16 CN 0.180 31.18 RB ENTRY SUPPORT-AIRLOCKS 840206 008405 C20H005 RB SUPP-0UTSIDE CTMT 75 CN 0.043 240.66 RB ENTRY SUPPORT-ANTEROOM
  • 840206 008405 C20H005 RB SUPP-OUTSIDE CTMT 8 HP 0.006 41.93 RB ENTRY SUPPORT-ANTERDOM
  • 840206 008405 C20H005 RB SUPP-OUTSIDE CTMT 3 OP 0.001 6.87 RB ENTRY SUPPORT-ANTER0OM
  • 840206 008405 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.000 1.32 RB ENTRY SUPPORT-ANTER0OM 840208 008422 C80N001 RB WASTE REMOVAL 1 OP 0.075 1.43 TRASH AND EQUIPMENT REMOVAL
  • 840208 008422 C80N001 RB WASTE REMOVAL 2 UM 0.091 2.95 TR ASH AND EQUIPME NT REMOVAL
  • 840208 008422 C80N001 RB WASTE REMOVAL 1 MM 0.005 1.47 TRASH AND EQUIPMENT REMOVAL 840210 008430 C80N001 RB WASTE REMOVAL 1 UM 0.198 2.40 REMOVE MISC STEEL AND RACKS FROM RB

DATE 022486 PAGE 48 PNO. 47 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER. NUMBER
  • .....................,..........IVITY ACT

..ENTR.....C. ODE.. REM...........................SK DESCRIPTION . HOURS TA

  • 840210 008430 C80N001 RB WASTE REMOVAL 1 CM 0.015.

3 87 REMOVE MISC STEEL AND RACKS FROM RB

  • 840210 008430 C80N001 RB WASTE REMOVAL 1 RP 0.009 1.77 REMOVE MISC STEEL AND RACKS FROM RB
  • 840210 008430 C80N001 RB WASTE REMOVAL 1 FN 0.146 2.45 REMOVE MISC STEEL AND RACKS FROM RB 840210 008432 C30D001 RB DECON-282 ' ELEV 4 CN 0.574 8.23 FLUSH VALVE SFV-104 & SURROUNDING AREA 840213 008442 C70H001 RB NAD SURVEYS 3 HP 0.187 4.03 HP SURVEYS / JOB COVERAGE
  • 840213 008442 C70H001 RB RAD SURVEYS 2 CN 0.522 5.73 HP SURVEYS / JOB COVERAGE 840213 008443 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.095 20.42 RB ENTRY SUPPORT 840213 008444 C20H005 RB SUPP-OUTSIDE CTMT 59 CN 0.025 172.76 RB ENTRY SUPPORT
  • 840213 008444 C20H005 RB SUPP-0UTSIDE CTMT 14 HP 0.005 67.78 RB ENTRY SUPPORT
  • 840213 008444 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.002 0.88 RB ENTRY SUPPORT 840215 008466 C20H006 RB SAFETY INSPECTION 1 AM 0.057 1.40 SAFETY INSPECTION
  • 840215 008466 C20H006 RB SAFETY INSPECTION 2 CN 0.135 2.78 SAFETY INSPECTION 840215 008468 C20H001 RB SUPPORT ACTIVITY 2 CN 0.475 5.85 NRC INSPECTION 840215 008469 C50H001 RB P.M.

AND SURVEY 1 CN 0.131 1.15 PLACE TLD STRINGS 840221 008488 C70H001 RB RAD SURVEYS 1 CN 0.100 1.97 HP SURVEYS / JOB COVERAGE $840221 008488 C70H001 RB RAD SURVEYS 1 HP 0.115 1.83 HP SURVEYS / JOB COVERAGE S40221 008496 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.003 29.02 RB ENTRY SUPPORT

  • 840221 008496 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.000 11.45 RB ENTRY SUPPORT

$840221 008496 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.40 RB ENTRY SUPPORT 840221 008497 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.009 2.80 RB ENTRY SUPPORT 840227 008526 C70H001 RB R AD SURVE YS 4 HP 0.603 6.10 HP SURVEYS / JOB COVERAGE m *840227 008526 C70H001 RB RAD SURVEYS 2 CN 0.050 0.95 HP SURVEYS / JOB COVERAGE ca 840227 008527 C45H001 RB CORRECTIVE MAINT 1 CA 0.060 0.68 REMOVE CABLE MB-531P

  • 840227 008527 C45H001 RB CORRECTIVE MAINT 2 CN 0.240 3.20 REMOVE CABLE MB-531P 840227 008531 C20H005 RB SUPP-0UTSIDE CTMT 20 CN 0.130 35.42 RB ENTRY SUPPORT-AIRLOCKS 840227 008532 C20H005 RB SUPP-0UTSIQE CTMT 74 CN 0.026 245.27 RB ENTRY SUPPORT-ANTEROOM
  • 840227 008532 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.002 50.88 RB ENTRY SUPPORT-ANTEROOM
  • 840227 008532 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 0.38 RB ENTRY SUPPORT-ANTEROOM 840301 008547 C20H005 RB SUPP-0UTSIDE CTMT 9 CN 0.002 13.85 CORE DRILL THROUGH FHB WEST WALL 840305 008561 C70H001 RB RAD SURVEYS 4 HP 0.262 3.72 HP SURVEYS / JOB COVERAGE

$840305*008561 C70H001 RB RAD SURVEYS 1 CN 0.034 0.83 HP SURVEYS / JOB COVERAGE 840305 008562 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.088 25.67 RB ENTRY SUPPORT-AIRLOCKS 840305 008563 C20H005 RB SUPP-0UTSIDE CTMT 55 CN 0.021 162.85 RB ENTRY SUPPORT-ANTER0OM

  • 840305 008563 C20H005 RB SUPP-0UTSIDE CTMT 19 HP 0.004 81.38 RB ENTRY SUPPORT-ANTEROOM
  • 240305 008563 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.001 1.02 RB ENTRY SUPPORT-ANTEROOM 840307 008584 C35N003 DOSE REDUCTION-305' 1 CM 0.240 1.95 REPAIR VACUUMS /REF(LL WATER SHIELDS
  • 840307 008584 C35N003 DOSE REDUCTION-305*

1 CN 0.165 1.97 REPAIR VACUUMS / REFILL WATER SHIELDS

  • 840307 008584 C35N003 DOSE REDUCTION-305*

1 IC 0.220 1.97 REPAIR \\ACUuMS/ REFILL WATLR SHIELDS 840307 008584 C35N003 DOSE REDUCTION-305* 1 CM 0.240 1.95 REPAIR VACUUMS / REFILL WATER SHIELDS

  • 840307 008584 C35N003 DOSE REDUCTION-305*

1 CN 0.165 1.97 REPAIR VACUUMS / REFILL WATER SHIELDS

  • 840307 008584 C35N003 DOSE REDUCTION-305*

1 IC 0.220 1.97 REPAIR VACUUMS / REFILL WATER SHIELDS 840307 008586 C45H001 RB CORRECTIVE MAINT 2 MM 0.118 3.45 AIRLOCK DOOR SURVEILLANCE 840308 008593 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.000 4.92 REMOVE INSULATION FROM SUPPLY LINE 840312 008597 C20H005 RB SUPP-0UTSIDE CTMT 18 CN 0.155 36.17 RB ENTRY SUPPORT-AIRLOCKS 840312 008598 C20H005 RB SUPP-OUTSIDE CTMT 68 CN 0.025 192.22 RB ENTRY SUPPORT-ANTE ROOM

  • 840312 008598 C20H005 RB $UPP-0UTSIDE CTMT 16 HP 0.003 84.55 RB ENTRY SUPPORT-ANTERDOM
  • 840312 008598 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.85 RB ENTRY SUPPORT-ANTEROOM
  • 840312 008598 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 0.85 RB ENTRY SUPPORT-ANTEROOM 840312 008599 C70H001 RB RAD SURVEYS 4 HP 0.365 6.73 HP SURVEYS / JOB COVERAGE
  • 840312 008599 C70H001 RB RAD SURVEYS 5 CN 0.327 5.87 HP SURVEYS / JOB COVERAGE

.~. - - - DATE 022486 PAGE 49 PNO. 48 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ACTIV ENTR. CODE... REM........ HOURS.................... T. ASK DE.S.C R I P T I O. N

  • DATE, NUPS.E.R, NUMBE.R.................ITY.........

3.......... 840312 008601 C20H006 RB SAFETY INSPECTION 1 AD 0.121 1.87 SAFETY INSPECTION 2840312 008601 C20H006 RB SAFETY INSPECTION 1 AM 0.163 1.85 SAFETY INSPECTION

  • 840312 008601 C20H006 RB SAFETY INSPECTION 1 CN 0.115 1.68 SAFETY INSPECTION 840314 008626 C80N001 RB WASTE REMOVAL 2 CN 0.302 4.73 EVALUATE CRD CABLE REMOVAL / PREP TRASH
  • 840314 008626 C80N001 RB WASTE REMOVAL 2 RP 0.260 4.62 EVALUATE CRD CABLE REMOVAL / PREP TRASH
  • 840314 008626 C80N001 RB WASTE REMOVAL 1 UM 0.115 1.98 EVALUATE CRD CABLE REMOVAL / PREP TRASH 840314 008629 C45H001 RB CORRECTIVE MAINT 1 IC 0.078 1.32 ALIGN MAGNETIC SWITCH-EQUIP HATCH DOOR 840315 008634 C20H002 RB - CCTV 3 IC 0.495 5.60 TV CAMERA RE PAIR 840316 008638 C80N001 RB WASTE REMOVAL 2 RP 0.309 3.43 PACKAGE CABLE SAMPLES / REMOVE TRASH
  • 840316 008638 C80N001 RB WASTE REMOVAL 1 UM 0.121 1 75 PACKAGE CABLE SAMPLES / REMOVE TRASH 840319 008642 C20H005 RB SUPP-0UTSIDE CTHT 15 CN 0.158 31.80 RB ENTRY SUPPOR T-AIRLOCKS 840319 008643 C20H005 RB SUPP-0UTSIDE CTMT 59 CN 0.011 156.31 RB ENTRY SUPPORT-ANTEROOM

$840319 008643 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.009 94.52 RB ENTRY SUPPORT-ANTERDOM 3840319 008643 C20H005 RB SUPP-0UTSIDE CTNT 4 OP 0.000 4.12 RB ENTRY SUPPOR T-ANTEROOM 840319 008645 C80N001 RB WASTE REMOVAL 1.R P 0.109 1.98 REMOVE IIF STUDS / REMOVE MISC TRASH

  • 840319 008645 C80N001 RB WASTE REMOVAL 1 CM 0.005 2.27 REMOVE IIF STUDS / REMOVE MISC TRASH
  • 840319 008645 C80N001 RB WASTE REMOVAL 1 EL 0.100 2.12 REMOVE IIF STUDS / REMOVE MISC TRASH
  • 840319 008645 C80N001 RB WASTE REMOVAL 1 OP 0.010 2.28 REMOVE IIF STUDS / REMOVE MISC TRASH
  • 840319 008645 C80N001 RB WASTE REMOVAL 1 UM 0.095 1 97 REMOVE-IIF STUDS / REMOVE MISC TRASH 840319 008648 C45H001 RB CORRECTIVE MAINT 3 CN 0.670 4.17 CLOSE DAMPERS IN AIR COOLER DUCT 840319 008649 C70H001 RB RAD SURVEYS S HP 0.761 8.18 HP SURVEYS / JOB COVERAGE 840321 008671 C20H001 RB SUPPORT ACTIVITY 4 CN 0.183 5.15 MOVE STAGING AREA - 347* LEVEL e

840321 008672 C45H001 RB CORRECTIVE MAINT 3 CN 0.542 3.87 CLOSE AIR COOLER DAMPERS 840321 008678 C45M001 RB CORRECTIVE MAINT 2 CN 0.143 1 62 DETERMINE TERMINAL E0X REQUIREMENTS 840322 008682 C80N001 RB WASTE REMOVAL 1 IC 0.015 1.49 REMOVE MISC STEEL AND TRASH - 305* LEVEL

  • S40322 008632 C80N001 RB WASTE REMOVAL 1 EL 0.106 1.47 REMOVE MISC STEEL AND TRASH - 305* LEVEL
  • 840322 008682 C80N301 RB WASTE REMOVAL 1 OP 0.008 1.50 REMOVE MISC STEEL AND TRASH - 305* LEVEL
  • 840322 008682 C80N001 RB WASTE REMOVAL 1 UM 0.106 1.52 REMOVE MISC STEEL AND TRASH - 305' LEVEL 840322 008683 C20H005 RB SUPP-0UTSIDE CTMT 20 CN O.015 40.52 INSTALL CHILLEO WATER PIPE

$840322 008683 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 1.08 INSTALL CHILLED WATER PIPE 840323 008690 C90K001 RB DATA ACQUISITION 1 CN 0.140 1.73 DATA ACQUISITION-305*, 347' & 'A' D RING

  • 840323 008690 C90M001 RB DATA ACQUISITION 1 HP 0.126 1.73 DATA ACQUISITION-305*, 347' &

'A' D RING 840326 008694 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.101 30.20 RB ENTRY SUPPORT-AIRLOCKS 840326 008695 C20H005 RB SUPP-0UTSIDE CTMT 67 CN 0.008 204.02 RB ENTRY SUPPORT-ANTEROOM

  • 840326 008695 C20H005 RB SUPP-OUTSIDE CTMT 12 HP 0.006 52.57 RB ENTRY SUPPORT-ANTEROOM
  • 840326 008695 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 3.93 RB ENTRY SUPPORT-ANTEROOM
  • 840326 008695 C20H005 RB SUPP-0UTSIDE CTMT 4 IC 0.000 4.30 RB ENTRY SUPPORT-ANTEROOM
  • 840326 008695 C20H005 RB SUPP-0UTSIDE CTMT 2 SE 0.000 1.93 RB ENTRY SUPPORT-ANTER0OM 840326 008697 C70H001 RB RAD SURVEYS 2 HP 0.093 1.57 HP SURVEYS / JOB COVERAGE
  • 840326 008697 C70H001 RB RAD SURVEYS 3 CN 0.303 4.75 HP SURVEYS / JOB COVERAGE 840328 008719 C90K001 RB DATA ACQUISITION 4 CN 0.320 4.83 REMOVE TRANSDUCE RS F ROM CFT-B 840328 008720 C80N001 RB WASTE REMOVAL 3 OP 0.286 6.15 REMOVE CORE DEBRIS SAMPLE AND MISC TRASH

$840328 008720 C80N001 RB WASTE REMOVAL 1 IC 0.010 2.17 REMOVE CORE DEBRIS SAMPLE AND MISC TRASH 5840328 008720 C80N001 RB WASTE REMOVAL 2 UM 0.307 3.80 REMOVE CORE DEBRIS SAMPLE AND MISC TRASH 840328 008721 C20H001 RB SUPPORT ACTIVITY 3 CN 0.654 7.55 CLEAN UP CIRBBINB - 347' LEVEL $40328 008724 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.005 17.70 INSTALL CHILLED WATER PIPE AND FORMS 840330 008736 C80N001 RB WASTE REMOVAL 2 CN 0.363 5.82 STAGE AND CUT NITROGEN PIPING

  • 840330 008736 C80N001 RB WASTE REMOVAL 1 AH 0.050 0.70 STAGE AND CUT NITROGEN PIPING 840330 008737 C20H005 RB SUPP-0UTSIDE CTMT 7 IC 0.002 24.53 REPAIR AND TEST UNDERWATER LIGHT 840402 008741 C80N001 RB WASTE REMOVAL 1 RP 0.102 1 17 SURVEY RB FOR TRASH REMOVAL l

i

= DATE 022486 PAGE 50 PNO. 49 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT EXPOS. TIME ACT . HOURS. TASK DESCRIPTION

  • D. A T E... NUMBE R. NUMBE.R........

.........IVITY . ENTR. C OD E.... R E.M .RB WASTE REMOVAL 1 CN 0.056

  • 840402 008741 C80N001 0.72 SURVEY RB FOR TRASH REMOVAL 840402 008746 C70H001 RB RAD SURVEYS 1 CN 0.161 2.18 HP SURVEYS / JOB COVERAGE 840402 008747 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.082 21.52 RB ENTRY SUPPORT-AIRLOCKS 840402 008748 C20H005 RB SUPP-0UTSIDE CTHT 50 CN 0.007 138.S5 RB ENTRY SUPPORT-ANTEROOM
  • 840402 008748 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.002 57.75 RB ENTRY SUPPORT-ANTEROOM
  • 840402 008748 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.001 1,53 RB ENTRY SUPPORT-ANTEROOM
  • 840402 008748 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.000 0.57 RB ENTRY SUPPORT-ANTER0OM
  • 840402 008748 C20H005 RB SUPP-0UTSIDE CIMT 1 CM 0.000 0.60 RB ENTRY SUPPORT-ANTERDOM 840402 008754 C20 HOC 5 RP SUPP-0UTSIDE CTMT 10 CN 0.001 10.92 FORM AND GROUT PENETRATION P 6102 840403 008908 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.058 22.60 RB ENTRY SUPPORT-AIRLOCKS 840404 008761 C80N001 RB WASTE REMOVAL 1 MM 0.185 2.35 LOW RAD TRASH REMOVAL
  • 840404 008761 C80N001 RB WASTE REMOVAL 1 IC 0.130

.?. 0 2 LOW RAD TRASH REMOVAL

  • S404C4 008761 C80N001 RB WASTE REMOVAL 1 UM 0.133 2.42 LOW RAD TRASH REMOVAL
  • 840404 008761 C80N001 RB WASTE REMOVAL 1 OP 0.113 1.97 LOW RAD TRASH REMOVAL 84G409 008781 C70H001 R B R AD SURVEYS 3 HP 0.201 3.77 HP SURVEYS / JOB COVERAGE 840409 008784 C80N001 RB WASTE REMOVAL 1 OP 0.031 2.83 REMOVE MISC STEEL AND WOOD
  • 840409 008784 C80N001 RB WASTE REMOVAL 1 IC 0.029 2.87 REMOVE MISC STEEL AND WOOD
  • 840409 008784 C80N001 RB WASTE REMOVAL 1 CM 0.159 2.78 REMOVE MISC STEE L AND WOOD E840409 008784 C80N001 RB WASTE REMOVAL 1 UM 0.013 2.78 REMOVE MISC STEEL AND WOOD 4840409 008784 C80N00) RB WASTE REMOVAL 1 MM 0.146 2.82 REMOVE MISC STEEL AND WOOD RB SUPP-0UTSIDE CTMT 74 CN 0.047 201.53 RB ENTRY SUPPORT-ANTEROOM

$' *840409 008786 C20H005 840409 008786 C20H005 RB SUPP-0UTSIDE CTMT 14 HP 0.005 82.92 RB ENTRf SUPPORT-ANTEROOM

  • 840409 008786 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000

. 13 RB ENTRY SUPPOR T-ANTEROOM 8404v9 008787 C20H005 RB SUPP-0UTSIDE CTMT 18 CN 0.126 29.33 RB ENTRY SUPPORT-AIRLOCKS 840411 008806 C80N001 RB WASTE REMOVAL 5 OP 0.632 13.60 HANDLE CRDM DRUMS

  • 840411 008806 C80N001 RB WASTE REMOVAL 1 IC 0.140 2.22 HANDLE CROM DRUMS
  • 840411 008806 C80N001 RB WASTE REMOVAL 2 CM 0.339 5.62 HANDLE CRDM DRUMS 840412 008808 C35N001 DOSE REDUCTION-P.C.

2 CN 0.106 2.03 MOVE OPERATORS SHIELD BOOTH 840416 008827 C20H006 RB SAFETY INSPECTION 2 CN 0.269 4.18 SAFETY INSPECTION

  • 840416 008927 C20H006 RB SAFETY INSPECTION 1 AM 0.154 2.17 SAFETY INSPECTION 340416 008828 C70H001 RB RAD SURVEYS 3 HP 0.298 2.27 HP SURVEYS / JOB COVERAGE
  • 840416 008828 C70H001 RB RAD SURVEYS 1 CN 0.061 1.87 HP SURVEYS / JOB COVERAGE 840416 008831 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.072 21,35 RB ENTRY SUPPORT-AIRLOCKS 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 57 CN 0.017 122.02 RB ENTRY SUPPORT-ANTEROOM
  • 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 22 HP 0.006 110.48 RB ENTRY SUPPORT-ANTEROOM
  • 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 1.08 RB ENTRY SUPPORT-ANTEROOM
  • S40416 008832 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.000 1.07 RB ENTRY SUPPORT-ANTEROOM
  • 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.001 0.23 RB ENTRY SUPPORT-ANTEROOM
  • 840416 008832 C20H005 RB SurP-0UTSIDE CTMT 1 CM 0.000 0.22 RB ENTRY SUPPORT-ANTEROOM 840417 008843 C80N001 RB WASTE REMOVAL 1 RP 0.150 1,67

$URVEY RB $840417 008843 C80N001 RB WASTE REMOVAL 1 CN 0.155 1.67 SURVEY RB 840418 008853 C35N003 DOSE REDUCTION-305* 4 CN 0.005 18.85 GAMMA SCAN OF CORE BORE SAMPLES 840419 008854 C80N001 RB WASTE REMOVAL 1 IC 0.048 0.88 LOW RAD TRASH REMOVAL 840419 008857 C80N001 RB WASTE REMOVAL 2 CN 0.199 3.70 CUT UP PIPE HANGER 840423 008862 C70H001 RB RAD SURVEYS 4 HP 0.157 3.23 HP SURVEYS / JOB COVERAGE 840423 008866 C20H005 RB SUPP-0UTSIDE CTMT 21 CN 0.145 36.47 RB ENTRY SUPPORT-AIRLOCKS 840423 008867 C20H005 RB SUPP-0UTSIDE CTMT 71 CN 0.029 224.11 RB E NTRY SUPPOR T-ANT E ROOM

  • 840423 008867 C20H005 RB SUPP-0UTSIDE CTMT 22 HP 0.000 88.38 RB E NTRY SUPPOR T-ANTE ROOM
  • 840423 008867 C20H0r5 RB SUPP-0UTSIDE CTMT 4 OP 0.007 3.30 RB ENTRY SUPPORT-ANTER0OM
  • 840423 008867 C20H065 RB SUPP-0UTSIDE CTMT 1 UM 0.000 0.63 RB ENTRY SUPPORT-ANTER0OM

r DATE 022486 PAGE 51 PNO. 50 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BultDING DECONTAMINATICt286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. A T E... NUMBE R. NUMBE.R

..........IVITY ACT ENTR. CODE... R E M.M.URS..................D. E. S.C R I P T I ON TASK 840425 008892 C80N001 R8 WASTE REMOVAL 1 UM 0,076 0.95 REHovE TRASH AND DRUMS

  • 840425 008892 C80N001 R8 WASTE REMOVAL 1 CM 0.077 0.95 REMOVE TRASH AND DRUMS 840426 C08898 C90h001 RB DATA ACOUISITION 4 CN 0.488 7.53 INSTALL SOLENDID & LIMIT SWITCH-AHV-2A 840426 008899 C35N003 DOSE REDUCTION-305' 3 CN 0.211 3.35 REMOVE SOLENOID VALVE AH-V2A 840430 008909 C20H005 RB SUPP-0UTSIDE CTMT 57 CN 0.017 129.41 R8 ENTRY SUPPORT-ANTER0OM

$840430 008909 C20H005 RB SUPP-0UTSIDE CTMT 13 HP 0.007 77.67 RB ENTRY SUPPORT-ANTEROOM 3840430 008909 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 1.12 RB ENTRY SUPPORT-ANTEROOM 840430 008913 C80N001 RB WASTE REMOVAL 1 IC 0.058 2.48 CRDM CABLE DRUM REMOVAL

  • 840430 008913 C8CN001 R8 WASTE REMOVAL 2 CM 0.085 5.20 CRDM CABLE DRUM REMOVAL

$840430 008913 C80N001 RB WASTE REMOVAL 1 OP 0.015 2.63 CRDM CABLE DRUM REMOVAL 840430 008914 C70H001 RB RAD SURVEYS 4 CN 0.150 3.45 HP SURVEYS / JOB COVERAGE 840503 008939 C80N001 RB WASTE REMOVAL 2 RP 0.380 4.25 TRASH REMOVAL / INSPECT SERVICE STRUCTURE

  • 840503 008939 C80N001 RB WASTE REr10 VAL 3 CN 0.531 5.37 TRASH REMOVAL / INSPECT SERVICE STRUCTURE 840507 008948 C70H001 RB RAD SURVEYS 4 HP 0.254 3.92 HP SURVEYS / JOB COVERAGE
  • 840507 008948 C70H001 R8 RAD SURVEYS 1 RP 0.100 1,62 HP SURVEYS / JOB COVERAGE
  • 840507 008948 C70H001 R8 RAD SURVEYS

.1 E N 0.022 3.68 HP SURVEYS / JOB COVERAGE 840507 008953 C20H005 R8 SUPP-0UTS!DE CTNT 63 CN 0.026 185.73 RB ENTRY SUPPORT-ANTEROOM

  • 840507 008953 C20H005 RB SUPP-0UTSIDE CTMT 8

H* 0.000 34.95 RB ENTRY SUPPORT-ANTEROOM 3840507 008953 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.37 RB ENTRY SUPPORT-ANTERCOM a

  • 840507 008953 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.000 1.38 R8 ENTRY SUPPORT-ANTERCOM cs 840507 008954 C20H005 RB SUPP-OL' SIDE CTMT 16 CN 0.088 25.57 RB ENTRY SUPPORT-AIRLOCKS Ch 840509 008971 C80N001 R8 WASTE REMOVAL 2 OP 0.125 5.13 REMOVE TRASH AND EQUIPMENT
  • 840509 008971 C80N001 RB WASTE REMOVAL 1 EL 0.007 2.92 REMOVE TRASH AND EQUIPMENT
  • 840509 008971 C80N001 R8 WASTE REMOVAL 2 CM 0.153 5.92 REMOVE TRASH AND EQUIPMENT 840509 008972 C30P001 DECON AIR COOLERS 3 CN 0.645 4 10 DECON INSPECTION 340514 008993 C70H001 R8 RAD SURVEES 1 HP 0.028 1.58 HP SURVEYS /JOS COVERAGE
  • 840514 008993 C70H001 RB RAD SURVEYS 3 CN 0.047 2.05 HP SURVEYS / JOB COVERAGE 840514 008996 C20H006 R8 SAFETY INSPECTION 1 AD 0.071 1.05 SAFETY INSPECTION 3840514 008996 C20H006 RB SAFETY INSPECTION 1 AM 0.062 1.87 SAFETY INSPECTION
  • 840514 008996 C20H006 R8 SAFETY INSPECTION 2 CN 0.206 2.47 SAFETY INSPECTION 840514 008997 C80N001 RB WASTE REMOVAL 3 EL 0.205
3.98 REMOVE AUX MAST AND MISC STEEL 2840514 008997 C80N001 RB WASTE REMOVAL 3 OP 0.588 7.75 REMOVE AUX MAST AND MISC STEEL
  • 840514 008957 C8CN001 R8 WASTE REMOVAL 2 UM 0.024 4.35 REMOVE AUX MAST AND MISC STEEL
  • 840514 008997 C80N001 R8 WASTE REMOVAL 2 CM 0.180 5.72 REMOVE AUX MAST AND MISC STEEL 840514 009000 C20H005 R8 SUPP-0UTSIDE CTMT 19 CN 0.107 35.73 R8 ENTRY SUP*0RT-AIRLOCKS 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 72 CN 0.002 180.61 RB ENTRY SUPPORT-ANTEROOM
  • 840514 009001 C20H005 R8 SUPP-0UTSIDE CTMT 12 HP 0.005 85.30 R8 ENTRY SUPPORT-ANTER0OM
  • 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.002 2.05 RB ENTRY SUPPORT-ANTEROOM 3840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 4 RC 0.000 23.72 RB ENTRi SUPPORT-ANTEROOM

$840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 4.82 RB ENTRY SUPPORT-ANTER0OM

  • 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 3 CM 0.005 4.62 RB ENTRY SUPPOR T-AN TE R OOM
  • 840514 009001 C20H005 R8 SUPP-0UTSIDE CTMT 1 UM 0.000 0.43 RB ENTRY SUPPORT-ANTER0OM 840517 009022 C80N001 RB WASTE REMOVAL 1 CN 0.059 1.22 EMPTY VACUUM COLLECTION DRL4tS - CANAL
  • 840517 009022 C80N001 R8 WASTE REMOVAL 1 UM 0.077 1.22 EMPTY VACUUM COLLECTION DRUMS - CANAL
  • 840517 009022 C80N001 RB WASTE REMOVAL 1 OP 0.060 1.18 EMPTY VACUUM COLLECTION DRUMS - CANAL 840521 009039 C70H001 R8 RAD SURVEYS 3 CN 0.060 2.10 HP SURVEYS / JOB COVERAGE
  • 840521 009039 C70H001 RB RAD SURVEYS 2 HP 0.119 1.70 HP SURVEYS / JOB COVERAGE 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 71 CN 0.037 195.95 R8 ENTRY SUPPORT-ANTE ROOM
  • 840521 009040 C20H005 R8 SUPP-0UTSIDE CTMT 8 HP 0.009 46.78 RB ENTRY SUPPORT-ANTEROOM
  • 840521 009040 C20H005 R8 SUPP-0UTSIDE CTMT 1 RC 0.000 0.83 RB ENTRY SUPPORT-ANTEROOM

DATE 022486 PAGE 52 PNO. 51 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME 3.DA TE... NUMBE.R. NUMBE R....................IVITY ..E.N T R....... REM................................... TION ACT . CODE . HOURS TA$K DESCRIP

  • 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 1.02.

.RB ENTRY SUPPORT-ANTEROOM

  • 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.70 R B E NTR Y SUPPORT-ANTE ROOM
  • 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.002 1.50 RB ENTRY SUPPORT-ANTER0OM 840521 009042 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.088 31.22 RB ENIRY SUPPOR T-AIRLOCKS
  • 340521 009042 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 3.53 RB ENTRY SUPPORT-AIRLOCKS 840523 009064 C80N001 RB WASTE REMOVAL 1 CM 0.152 1.55 LOAD CONDUCTOR BARS AND TRASH

$840523 009064 C80N001 RB WASTE REMOVAL 1 IC 0.163 1.58 LOAD CONDUCTOR BARS AND TRASH

  • 840523 009064 C80N001 RB WASTE REMOVAL 1 CN 0.053 0.82 LOAD CONDUCTOR BARS AND TRASH

$840523 009064 C80N001 RB WASTE REMOVAL 1 RP 0.051 0.78 LOAD CONDUCTOR BARS AND TRASH 840525 009061 C35N003 DOSE REDUCTION-305* 5 CN 0.000 35.58 GAMMA SCAN OF CONCRETE BORINGS 840525 009073 C80N001 RB WASTE REMOVAL 2 RP 0.013 4.53 REMOVE AFHB WASTE

  • S40525 009073 C80N001 RB WASTE REMOVAL 2 OP 0.569 3.80 REMOVE AFHB WASTE
  • $40525 009073 C80N001 RB WASTE REMOVAL 1 EL 0.135 1.90 REMOVE AFHB WASTE
  • S40525 009073 C80N001 RB WASTE REMOVAL 2 CM 0.019 4.10 REMOVE AFHB WASTE

$840525 009073 C80N001 RB WASTE REMOVAL 1 IC 0.142 1.89 REMOVE AFHB WASTE 840530 0090S9 C70H001 RB RAD SURVEYS 2 HP 0.176 2 28 HP SURVEYS / JOB COVER AGE 840530 009100 C20H005 RB SUPP-0UTSIDE CTMT 24 CN 0.019 48 65 RB ENTRY SUPPORT-ANTEROOM

  • 840530 009100 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.000 49.50 RB ENTRY SUPPORT-ANTEROGM

$840530 009100 C20H005 RB 7.F ?-0UTSIDE CTMT 1 OP 0.000 0.65 RB ENTRY SUPPORT-ANTERDOM 840530 009101 C20H005 RB SUPP-0UTSIDE CTMT 6 CN 0.036 8.94 RB ENTRW SUPPORT-AIRLOCKS e

  • 840530 009101 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 0.08 RB ENTRY SUPPORT-AIRLOCKS l

m 840604 009119 C35N002 DOSE REDUCTION-347' 6 CN 0.430 8.93 STAGE EQUIP FOR SCABBLING TEST %4

  • 840604 009119 C35N002 DOSE REDUCT10N-347*

1 HP 0.060 0.77 STAGE EQUIP FOR SCABBLING TEST l 8 840E04 009121 C70H001 RB RAD SURVEYS 5 HP 0.252 3.15 HP SURVEYS / JOB COVERAGE j $840604 009121 C70H001 RB RAD SURVEYS 1 CN 0.018 0.28 HP SURVEYS / JOB COVERAGE 840604 009122 C20H005 RB SUPP-0UTSIDE CTMT 90 CN 0.017 232.21 RB ENTRY SUPPORT-ANTERCOM

  • 840604 009122 C20H005 RB SUPP-0UTSIDE CTMT 22 HP 0.006 121.45 RB ENTRY SUPPORT-ANTER0OM
  • 340604 009122 C20H005 RB SUPP-0UTSIDE CTMT 2 RC 0.000 7.57 RB ENTRY SUPPORT-ANTEROOM

$40604 009123 C20H005 RB SUPP-OUTSIDE CTMT 28 CN 0.149 49.78 RB ENTRY SUPPORT-AIRLOCKS 840605 009133 C35N002 DOSE REDUCTION-347' 28 CN 2.995 50.68 SCABBLE. CLEAN AND PAINT FLOOR

  • 840605 009133 C35N002 DOSE REDUCTION-347*

1 HP 0.045 0.67 SCABBLE, CLEAN AND PAINT FLOOR 840605 009140 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.000 3.32 DRILL HOLES IN AUX WALL 840606 009145 C20H005 RB SUPP-OUTSIDE CTMT 2 OP 0.002 6.38 DRAIN RB COOLING SYSTEM TO SUMP

  • 840606 009145 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.002 1.27 DRAIN RB COOLING SYSTEM TO SUMP 840607 009149 C80N001 RB WASTE REMOVAL 1 RP 0.205 2.28 TR ASH AND EQUIPME NT REMOVAL 2840607 009149 C80N001 RB WASTE REMOVAL 1 GP 0.016 2.13 TRASH AND EQUIPMENT REMOVAL 3540607 009149 C80N001 RB WASTE REMOVAL 1 IC 0.230 2.32 TR ASH AND EQUIPMENT REMOVAL
  • 840607 009149 C80N001 RB WASTE REMOVAL 1 CM 0.015 1.93 TRASH AND EQUIPMENT REMOVAL 840607 009151 C20H005 RB SUPP-0UTSIDE CTMT 35 CN 0.114 99.15 CUT EXISTING RB CHILLER LINES 840608 009155 C35N002 DOSE REUUCT10N-347*

1 CN 0.325 1.50 CONTAMINATION CONTROL

  • 840608 009155 C35N002 DOSE REDUCTION-347*

2 CM 0.216 2.30 CONTAMINATION CONTROL

  • 840608 009155 C35N002 DOSE REDUCTION-347*

1 IC 0.109 1.40 CONTAMINATION CONTROL 3840608 009155 C35N002 DOSE REDUCTION-347* 1 OP 0.155 1.48 CONTAMINATION CONTROL 840608 009157 C90K001 RB DATA ACQUISITION 1 HP 0.103 0.60 TLD STUDY - 305' ELEV 840610 009168 C70H001 RB RAD SURVEYS 5 CN 0.189 2.82 HP SURVEYS / JOB COVERAGE 840610 009169 C45H001 RB CORRECTIVE MAINT 2 MM 0.095 3.25 MAINTENANCE ON AIRLOCK EQUIPMENT 840611 0091Tt C20H005 RB SUPP-0UTSIDE CTMT 23 CN 0.115 53.02 RB E NTR V SUPPORT-AIRLOCKS

  • S40611 0091/1 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0 000 1.88 PB ENTRY SUPPORT-AIRLOCKS 840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 70 CN 0.024 239.91 RB ENTRY SUPPORT-ANTEROOM j
  • 840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 13 HP 0.003 76.42 RC ENTRY SUPPORT-ANTEROOM

DATE 022486 PAGE 53 PNO. 52 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

_RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE.. NUMBE.R, NUMBER..........,............ITY.........,.........E.NTR..... C OD E.... R E M,....... HOURS........................E.SCRIPTION ACTIV TASK D

.RB ENTRY SUPPORT-ANTEROOM 2840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 2.88 8840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0 000 1,43 RB ENTRY SUPPORT-ANTER0OM 840614 009201 C20H005 RB SUPP-0UTSIDE CTMT 8 CN 0.014 12.03 WELD WELLOLETS/RUN TUBING 840614 009204 C90K001 RB DATA ACQUISITION 1 CM 0.000 1.68 UCI ANALYSIS OF PAINT CHIPS 3840614 009204 C90K001 RB DATA ACQUISITION 1 CN 0.001 1.67 UCI ANALYSIS OF PAINT SHIPS 840618 009219 C20H006 RB SAFETY INSPECTION 1 AM 0.082 1.13 SAFETY INSPECTION 8840618 009219 C20H006 RB SAFETY INSPECTION 1 CN 0.090 1.08 SAFETY INSPECTION 8840618 009219 C20H006 RB SAFETY INSPECTION 1 HP 0.077 1.15 SAFETY INSPECTION 840618 009222 C70H001 RB RAD SURVEYS 3 HP 0.038 1.24 HP SURVEYS / JOB COVERAGE 3840618 009222 C70H001 RB RAD SURVEYS 1 CN 0.030 0.43 HP SURVEYS / JOB COVE RAGE 840618 009226 C20H005 RB SUPP-0UTSIDE CTMT 29 CN 0.186 53.85 RB ENTRY SUPPORT-AIRLOCKS

  • 840618 009226 C20H005 RB SUPP-0UTSIDE rTMT 1 OP 0.000 0.87 RB ENTRY SUPPORT-AIRLOCKS 840618 009227 C20H005 RB SUPP-0UTSIDE CTMT 120 CN 0.052 387.05 RB ENTRY SUPPORT-ANTEROOM

$840618 009227 C20H005 RB SUPP-0UTSIDE CTMT IS HP 0.002 80.50 RB ENTRY SUPPOR T-ANTEROOM 840618 009242 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.030 22.55 RUN TUBING / CLEAN AREA / REMOVE SCAFFOLD 840621 009261 C80N001 RB WASTE REMOVAL 1 RP 0.133 1.52 RB TRASH INSPECTION 8840621 009261 C80N001 RB WASTE REMOVAL 1 CN 0.128 1.47 RB TRASH INSPECTION 340621 009264 C20H006 RB SAFETY INSPECTION 1 AM 0.146 1.28 ESTABLISH SAFE ACCESS - SFV-104 840625 009291 C70H001 RB RAD SURVEYS 4 HP 0.248 3.07 HP SURVEYS / JOB COVERAGE $ 2840625 009291 C70H001 RB RAD SURVEYS 5 CN 0.316 5.22 HP SURVEYS / JOB COVERAGE CO 840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 154 CN 0.033 450.12 RB ENTRY SUPPORT-ANTER0OM e

  • 840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 29 HP 0.028 152.55 RB E NTRY SUPPOR T-AN TE R0OM 3840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.63 RB ENTRY SUPPORT-ANTEROOM
  • 340625 009305 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.001 1.38 RB ENTRY SUPPORT-ANTEROOM E840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 0.05 RB ENTRY SUPPORT-ANTEROOM
  • 840625 009305 C20H005 RB SUPP-0UTS!OE CTMT 1 RP 0.002 1.40 RB E NTR Y SUPPOR T-ANTE ROOM 3840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.002 1.37 RB ENTRY SUDPORT-ANTER0OM
  • 840625 009305 C2CH005 RB SUPP-0UTSIDE CTMT 1 RC 0,000 8.67 RB ENTRY SUPPORT-ANTEROOM 840625 009306 C20HOCS RB SUPP-0UTSIDE CTMT 35 CN 0.394 70.72 RB ENTRY SUPPORT-AIRLOCKS
  • 840625 009306 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 0.38 RB ENTRY SUPPORI-AIRLOCKS 840626 009310 C80N001 RB WASTE REMOVAL 2 RP 0.020 3.73 REMOVE MISC STEEL
  • 840626 009310 C80N001 RB WASTE REMOVAL 2 OP 0.270 3.82 REMOVE MISC STEEL 840627 009324 C80N001 RB WASTE REMOVAL 1 OP 0.096 0.95 REMOVE MISC STEEL

$340627 009324 C80N001 RB WASTE REMOVAL 1 IC 0.100 1.80 REMOVE MISC STEEL

  • 840627 009324 C80N001 RB WASTE REMOVAL 1 RP 0.034 0.85 REMOVE MISC STEEL
  • S40627 009324 C80N001 RB WASTE REMOVAL 1 EL 0.116 1.80 REMOVE MISC STEEL 840628 009330 CBCN001 RB WASTE REMOVAL 2 OP 0.165 2.30 REMOVE TRASH /CRDM CLOSURES 840702 009353 C70H001 RB RAD SURVEYS 3 HP 0.165 2.67 HP SURVEYS /TOB COVERAGE

$840702 009353 C70H001 RB RAD SURVEYS 2 CN 0.020 1.17 HP SURVEYS / JOB COVERAGE 840702 009361 C20H005 RB SUPP-0UTSIDE CTMT 32 CN 0.269 62.07 RB ENTRY SUPPORT-AIRLOCKS 840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 126 CN 0.064 381.10 RB ENTRY SUPPORT-ALL AREAS

  • 840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.005 56.67 RB ENTRY SUPPORT-ALL AREAS 3840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.002 8.62 RB ENTRY SUPPORT-ALL AREAS
  • 840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.000 5.90 RB ENTRY SUPPORT-ALL AREAS
  • 840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.005 2.70 RB ENTRY SUPPORT-ALL AREAS 3840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.003 2.50 RB ENTRY SUPPORT-ALL AREAS 840703 009370 C80N001 RB WASTE REMOVAL 2 RP 0.375 3.47 RB TRASH INSPECTION
  • 840703 009370 C80N001 RB WASTE REMOVAL 1 CN 0.200 1.77 RB TRASH INSPECTION 840703 009372 C80N001 RB WASTE REMOVAL 2 CN 0.230 2.62 CUT UP MISC STEEL 840706 009388 C80N001 RB WASTE REMOVAL 1 IC 0.006 1.42 RB TRASH REMOVAL l

. ~. . -... - - - ~ ~ - _ DATE 052286 PAGE 54 PNO. 53 RID 24 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 O

  • RWP

.RWP .EXP TRCK. PERS.DE PT. EXPOS. TIME TASK DESCRIPT .................I.ON .............. REM........ HOURS............... ENTR. CODE

  • DATE... NUMBER. NUMBER.........................TIVITY.............

AC

  • 810706 009388 C80N001 RB WASTE REMOVAL 2 RP 0.160 3.08 RB TRASH REMOVAL
  • 840706 009338 C80N001 RB WASTE REMOVAL 1 OP 0.139 1.80 RB TRASH REMOVAL 4840706 009388 C80N001 RB WASTE REMOVAL 1 CN 0.190 1.82 RB TRASH REMOVAL 840709 009403 C70H001 RM RAD SURVEYS 5 HP 0.371 9.30 HP SURVEYS / JOB COVERAGE

$$40709 009403 C70H001 RB RAD SURVEYS 4 CN 0.306 2.02 HP SURVEYS /JOS COVE R AGE 840709 009409 C20H005 RB SUPP-OUTSIDE CTMT 24 CN 0.157 42 83 RB ENTRY SUPPORT-AIRLOCKS 840709 009410 C20H005 RB StfPP-0UTSIDE CTMT 89 CN 0.050 292.47 RB E NTRY SUPPORT-ALL ARE AS 1

  • 840709 009410 C20H005 RB SUPP-0UTSIDE CTMT 19 HP 0.009 93.62 RB ENTRY SUPPORT-ALL AREAS 3840709 009410 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.003 11.52 RB ENIRY SUPPOR T-ALL ARE AS
  • 840709 009410 C20H005 RB SUPP-0UTSIDE CTMT 4 RP 0.006 10.03 RB ENTRY SUPPORT-ALL AREAS 4840709 009410 C20H005 RB SUPP-OUTSIDE CTMT 4 CM 0.002 11.85 RB ENTRY SUPPOR T-ALL ARE AS 840710 009419 C20H001 RB SUPPORT ACTIV11Y 1 CN 0.045 0.97 GENERAL INSPECTION - ALL ELEVATIONS 840711 009427 C80N001 RB WASTE REMOVAL 2 OP 0.512 4.83 RB TRASH REMOVAL
  • S40711 009427 C80N001 RB WASTE REMOVAL 2 RP 0.022 4.48 RB TRASH REMOVAL 840713 009445 C20H001 RB SUPPORT ACTIVITY 2 OP 0.109 2.13 MANAGEMENT INSPECTION 8840713 009445 C20H001 RB $UPPORT ACTIVITY 3 CN 0.141 3.22 MANAGEMENT INSPECTION
  • S40713 009445 C20H001 RB SUPPORT ACTIVITY

! CR 0.049 0.97 MAN AGE ME N T INSPECTION 340713 009446 C80N001 RB WASTE REMOVAL 2 RP 0.020 2.83 RB TRASH REMOVAL 8840713 009446 C80N001 RB WASTE REMOVAL 2 OP 0.300 2.97 RB TRASH REMOVAL

  • 840713 009446 C80N001 RB WASTE REMOVAL 1 CN 0.175 1.55 RB TRASH REMOVAL 840716 009454 C70H001 RB RAD SURVEYS 9 HP 0.452 10.05 HP SURVEYS / JOB COVERAGE

$840716 009454 C70H001 RB RAD SURVEYS 5 CN 0.148 3.77 HP SURVEiS/ JOB COVERAGE 840716 009455 C20H006 RB SAFETY INSPECTION 1 AM 0.054 1.30 SAFETY INSPECTION

  • 840716 009455 C20H006 RB SAFETY INSPECTION 2 CN 0.126 2.53 SAFETY INSPECTION 340716 009463 C20H005 RB SUPP-0UTSIDE CTMT 241 CN 0.135 819.94 RB ENTRY SUPPORT-ANTEROOM

$840716 009463 C20H005 RB SUPP-0UTSIDE CTMT 37 HP 0.007 218.62 RB ENTRY SUPPORT-ANTEROOM h'$ *340716 009463 C20H005 840716 009463 C20H005 RB SUPP-QUTSIDE CTMT 1 CM 0.000 0.85 RB ENTRY SUPPORT-ANTEROOM i

  • RB SUPP-0UTSIDE CTMT 4 RP 0.002 6.37 RB ENTRY SUPPORT-ANTEROOM 840716 009464 C20H005 RB SUPP-0UTSIDE CTMT 62 CN 0.408 115.70 RB ENTRY SUPPORT-AIRLOCKS 840717 009479 C80N001 RB WASTE REMOVAL 1 RP 0.017 0.60 RB TR ASH REMOVAL 840718 009483 C20H002 RB - CCTV 2 IC 0.174 4.35 HEAD LIFT MONITORING SYSTEMS
  • 840718 009453 C20H002 RB - CCTV 10 CN 0.835 20.03 HE AD LIF T MONITORING SYSTEMS 840718 009485 C20H001 RB SUPPORT ACTIVITY 3 CN 0.327 7.32 NRC INSPECTION 340718 009487 C90K001 RB DATA ACQUISITION 1 ES 0.079 1.57 DATA ACQUISITION-TLD TREES AND STRINGS
  • 840718 009487 C90Kf01 RB DATA ACQUISITION 1 CN 0.070 1.80 DATA ACQUISITION-TLD TREES AND STRINGS 840719 009495 C20H;02 RB - CCTV 3 CN 0.146 3.87 INSTALL CAMERA MULTIPLEXER 840719 009501 C20w002 RB - CCTV 3 IC 0.249 7.03 REPAIR CAMERA FOR LIFT MONITORING 840720 009508 C20H002 RB - CCTV 2 IC 0.084 2.87 REPAIR CCTV SYSTEM 840721 009511 C20H002 RB - CCTV 3 CN 0.262 4.95 RELOCATE CAMERA 5 840722 009518 C90K001 RB DATA ACQUISITION 2 CN 0.075 1.40 TLD CHARACTERIZATION CF RB

$840722 009518 C90K001 RB DATA ACQUISITION 1 RP 0.093 2.67 TLD CHARACTERIZATION OF RB $340722 009518 C90K001 RB DATA ACQUISITION 1 ES 0.073 1.47 TLD CHARACTERIZATION OF RB $40723 009519 C20H006 RB SAFETY INSPECTION 1 CN 0.082 1.38 INSPECT P.C. FOR COMBUSTIBLES

  • 840723 009519 C20H006 RB SAFETY INSPECTION 1 ES 0.070 1.32 INSPECT P.C.

FOR COMBUSilBLES 840723 009525 C70H001 RB RAD SURVEYS 7 HP 0.421 8.95 HP SURVEYS / JOB COVERAGE

  • 840723 009525 C70H001 RB RAD SURVEYS 1 RC 0.086 1.47 HP SURVEYS /JOS COVERAGE
  • 840723 009525 C70H001 RB RAD SURVEYS 3 CN 0.109 2.65 HP SURVEYS / JOB COVERAGE i

340723 009533 C20H005 RB SUPP-0UTSIDE CTMT 177 CN 0.079 571.49 RB ENTRY SUPPORT-ANTEROOM 8840723 009533 C20H005 RB SUPP-0UTSIDE CTMT 19 HP 0.001 146.43 RB ENTRY SUPPORT-ANTEROOM 8840723 009533 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.48 RB ENTRY SUPPORT-ANTER0OM

DATE 022486 PAGE 55 PNO. 54 TMI-2 UNC: TDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP T.CK PERS. DEPT. EXPOS. TIME ......... E. N T R ........ HOURS................E.SCRIPTION . CODE. REM TASK D ..........IVITY............ ACT

  • DATE. NUMBER.NUMBEt

.RB ENTRY SUPPORT-ANTER00M

  • 840723 009333 C20H003 RB SUPP-0UTSIDE CTMT 1 AM 0.000 0,75 840723 009534 C20H005 R8 SUPP-0UTSIDE CTMT 55 CN 0.344 97.22 RB ENTRY SUPPORT-AIRLOCKS 840730 009568 C90K001 R8 DATA ACQUISITION 1 RP 0 060 0.98 TLD PLACEMENT
  • 840730 009568 C90K001 RB DATA ACQUISITION 1 ES 0.062 1.03 TLD PLACEMENT 840730 009571 C70H001 RB RAD SURVEYS 3 HP 0.140 2.10 HP SURVEYS / JOB COVERAGE

$$40730 009571 C70H001 RB RAD SURVEYS 2 CN 0.090 2.35 HP SURVEYS / JOB COVERAGE 840730 009580 C20H005 RB SUPP-0UTSIDE CTMT 77 CN 0,018 212.12 RB ENTRY SUPPORT-ANTEROOM 3840730 009580 C20H005 18 SUPP-OUTSIDE CTMT 11 HP 0.025 41.35 P8 ENTRY SUPPORT-ANTEROOM $840730 009580 C20H005 dB SUPP-0UTSIDE CTMT 1 CM 0.000 2.65 RB ENTRY SUPPORT-ANTEROOM

  • 840730 009580 C20H005 RB $UPP-0UTSIDE CTMT 3 UM 0.024 5.60 RB ENTRY SUPPORT-ANTEROOM
  • 340730 009580 C20H005 1B SUPP-0UTSIDE CTMT 4 CP 0.021 4.38 RB ENTRY SUPPORT-ANTEROOM 840730 009581 C20H005 18 CUPP-0UTSIDE CTMT 14 CN 0.121 26.55 RB ENTRY SUPPORT-AIRLOCKS 840731 009594 C20H001 &B SUPPORT ACTIVITY 3 CN 0.315 3.97 INSPECT PROPOSED SCABBLING OPERATIONS 840731 009595 C80N001 93 WASTE REMOVAL 4 CM 0,363 8.00 RB TRASH INSPECTION
  • 840731 009595 C80N001 El WASTE REMOVAL 3 RP 0.217 2.60 RB TRASH INSPECTION 8840731 009595 C80N001 R1 WASTE REMOVAL 1 CN 0.064 0.83 RB TRASH INSPECTION 840802 009506 C90K001 R e' DATA ACQUISITION 1 HP 0.060 1.27 DATA ACQUISITION-305', 347' AND CANAL
  • 840802 009606 C90K001 RL DATA ACQUISITION 1 CN 0.074 1.28 DATA ACQUISITION-305*. 347' AND CANAL 840802 009607 C35N002 DCSE REDUCT!0N-347*

38 CN 4.229 69.82 SET UP EQUIP AND SCABBLE BY STAIRS e 840803 009615 C50H001 RB 2.M. AND SURVEY 5 CN 0.590 9.38 ELECTRICAL CHECK ON FTS CABLES %J 840806 009626 C90K001 RB bATA ACQUISITION 3 CN 0.169 3.50 DATA ACQUISITION-305' 347' AND CANAL C3 3840806 009626 C90K001 RB SATA ACQUISITION 1 OP 0.030 0.73 DATA ACQUISITION-305*, 347' AND CANAL l

  • 840806 009626 C90K001 RB 3ATA ACQUISITION 2 HP 0.062 1.50 DATA ACQUISITION-305'. 347' AND CANAL 840806 009628 C70H001 RB RAD SURVEYS 3 HP 0.282 3.80 HP SURVEYS / JOB COVERAGE
  • 840806 009628 C70H001 R S b aD SUR VE T S 2 CN 0.092 1.18 HP SURVEYS / JOB COVERAGE 840806 009637 C20H005 RB $9PP-0UTSIGE CTMT 19 CN 0.100 35.53 RB ENTRY SUPPORT-AIRLOCKS i

840806 009639 C20H005 RB SJSP-0UTSIDE CTMT 72 CN 0.023 191.02 RB ENTRY SUPPORT-ANTEROOM

  • 840806 009639 C20H005 RB SoPP-0UTSIDE CTMT 20 HP 0.009 97.97 RB ENTRY SUPPORT-ANTER0OM 840807 009644 C20H007 MANACiMENT TOURS 1 RP 0.038 0.77 DECON INSPECTION - D-197 840807 009646 C50H001 RB P 1.

AND SURVEY I >H 0.071 1.57 MOVE TOOLS / STAGE EQUIPMENT

  • 840807 009646 C50H001 RB P M AND SURVEY 1 EL 0.084 1.45 MOVE TOOLS / STAGE EQUIPMENT 8840807 009646 C50h001 R B P.I'.

AND SURVEY 1 CN 0.081 1.50 MOVE TOOLS / STAGE EQUIPMENT 840807 009647 C50H001 RB P k. AND SURVEY 2 CN 0.156 2.33 REPAIR SCAB 8LER 840808 009654 C20H007 MANAGE 1ENT TOURS 1 CN 0.035 0.63 DECON INSPECTION - 347' LEVEL 840808 009655 C45H001 RB CCP ECTIVE MAINT 6 CN 0.F15 9.74 INSTALL P3WER CABLE TERMINAL BOX 840808 009657 C35N003 DOSE R13UCTION-305' 1 CN 0.0,3 0.93 PRE-SCABBLE DATA ACQUISITION

  • 840808 009657 C35N003 DOSE RE)UCTION-305' 1 ES 0.088 0.87 PRE-SCABBLE DATA ACQUISITION 840809 009663 C35N002 DOSE RE.iUCTION-347' 3 CN 0.339 5.43 SCRU8 AND PAINT FLOOR 840809 009664 C35h002 DOSE RE1UCTION-347' 14 CN 2.013 16,95 SCABBLE. CLEAN & PAINT NEAR EQUIP HATCH 840810 009672 C20H007 MANAGEMt1T TOURS 1 CN 0.029 0.68 DECON INSPECTION - 305' SCABBLED AREA 840813 009680 C35N002 DOSE RED JCTION-347' 35 CN 3.776 67.43 SCABBLE CLEAN & PAINT 840813 009681 C70H001 R8 RAD SJRVEYS 1 HP 0.040 0.67 HP SURVdVS/ JOB COVERAGE
  • 840813 009681 C70H001 RB RAD SLRVEYS 4 CN 0.157 3.08 HP SURVEYS / JOB COVERAGE 840813 009682 C20H005 RB SUPP-C JTSIDE CTMT 98 CN 0.023 297.58 R8 ENTRY SUPPORT-ANTEROOM 8840813 009682 C20H005 RB SUPP-CJTSIDE CTMT 9 HP 0.004 40.50 PB ENTRY SUPPORT-ANTEROOM
  • 840813 009682 C20H005 RB SUPP-0UTSIDE CTMT 3 CM 0.004 7.31 R8 ENTRY SUPPORT-ANTEROOM

$840813 009682 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.002 4.22 R8 ENTRY SUPPORT-ANTEROOM

  • 840813 009682 C20H005 RB SUPP-0VTSIDE CTMT 1 MM 0.001 1.22 R8 ENTRY SUPPOR T - AN TE ROOM
  • 840813 009682 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 1.48 R8 ENTRY SUPPORT-ANTEROOM 840813 009683 C20H005 RB SUPP-0UTSIDE CTMT 21 CN 0.123 38.70 RB ENTRY SUPPORT-AIRLOCKS I

1

DATE 022486 PAGE 56 PNO. 55 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS.T ME

  • DATE... NUMBER.NUMSER......................ITY

...........................................ESCRIPTION ACTIV ENTR. CODE. REM . HOURS TASK D s.... 0.000. 1.15. INSTALL 120 VOLT OUTLET IN AIRLOCK 840814 009701 C20H005 RB SUPP-0UTSIDE CT41T 2 CN 840814 009706 C80N001 RB WASTE REMOVAL 6 CN 0.589 6.02 REMOVE HIGH RE ACH F ROM RB 840815 009704 C35N002 DOSE REDUCTION-347' 4 CN 0.380 E.08 MOVE MATERIALS 840815 009705 C20H007 MANAGEMENT TOURS 1 HP 0.079 1.10 MANAGEMENT INSPECTION - 305'--367* LEVELS 3840815 009705 C20H007 MANAGEMENT TOURS 1 VI 0.062 1.15 MANAGEMENT INSPECTION - 305*--367* LEVELS 840815 009707 C50H001 RB P.M. AND SURVEY 1 OP 0.107 1.57 REMOVE NLB HOSE $340815 009707 C50H001 RB P.M. AND SURVEY 2 CN 0.225 3.72 REMOVE NLB HOSE 840817 009717 C80N001 RB WASTE REMOVAL 2 RP 0.050 1.90 LOW RAD TRASH REMOVAL

  • 840817 009717 C80N001 RB WASTE REMOVAL 1 CN 0.000 2.33 LOW RAD TRASH REMOVAL 840820 009726 C70H001 RB RAD SURVEYS 4 HP 0.271 4.37 HP SURVEYS / JOB COVERAGE
  • 840820 009726 C70H001 RB RAD SURVEYS 3 CN 0.102 2.07 HP SURVEYS / JOB COVERAGE 840820 009727 C35N003 DOSE REDUCTION-305*

1 HP 0.025 0.37 PRE-SCABBLE DATA ACQUISITION 840820 009729 C35N002 DOSE REDUCTION-347* 22 CN 1.959 40.57 SCABBLE WET VACUUM AND PAINT FLOOR 840820 009730 C20H006 RB SAFETY INSPECTION 1 AD 0.145 2.65 SAFETY INSPECTION

  • 840820 009730 C20H006 RB SAFETY INSPECTION 2 CN 0.266 5.25 SAFETY INSPECTION 840820 009732 C20H005 RB SUPP-0UTSIDE CTMT 22 CN 0.168 43.87 RB ENTRY SUPPORT-AIRLOCKS
  • 840820 009732 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.011 1.98 RB ENTRY SUPPORT-AIRLOCKS
  • 840820 009732 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.020 1.92 RB ENTRY SUPPORT-AIRLOCKS 840820 005733 C20H005 RB SUPP-0UTSIDE CTMT 88 CN 0.046 231.16 RB E NTRY SUPPOR T-ANTEROOM 3840820 009733 C20H005 RB $UPP-0UTSIDE CTMT 15 HP 0.061 81.47 RB ENTRY SUPPORT-ANTER0OM 8

3840820 009733 C20H005 RB SUPP-0UTSIDE CTMT 2 MM 0.000 1.50 PB ENTRY SUPPORT-ANTEROOM d, 2840820 009733 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.53 RB ENTRY SUPPORT-ANTER0OM

  • S40820 009733 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.002 2.07 RB ENTRY SUPPORT-ANTEROOM 3840820 009733 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.95 RB ENTRY SUPPORT-ANTEROCM 8840820 009733 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.002 0.52 RB ENTRY SUPPORT-ANTEROOM 840821 009748 C50H001 RB P.M.

AND 54)RVE Y 2 CN 0.156 2.33 GENERAL MAINTENANCE ON SCABBLER UNITS 840822 009753 C90K001 RB DATA ACQUISITION 1 OP 0.060 1.07 DATA ACQUISITION /0PERATIONS SUPPORT

  • 840822 009753 C90K001 RB DATA ACQUISITION 1 CN 0.029 0.67 DATA ACQUISITION /0PERATIONS SUPPORT 840822 009754 C80N001 RB WASTE REMOVAL 2 MM 0.289 5.02 REMOVE EQUIPMENT
  • S40822 009754 C80N001 RB WASTE REMOVAL 3 OP 0.477 6.37 REMOVE EQUIPMENT

$840822 009754 C80N001 RB WASTE REMOVAL 1 IC 0.095 1.33 REMOVE EQUIPMENT

  • 840822 009754 C80N001 RB WASTE REMOVAL 2 CM 0.227 3.87 REMOVE EQUIPMENT 840822 009755 C80N001 RB WASTE REMOVAL 4 CN 0.541 8.85 LOWER PENDANTS & TURNBUCKLES TO 305'ELEV 840823 009760 C20H007 MANAGEMENT TOURS 1 CN 0.060 1.03 MANAGEMENT INSPECTION - ALL AREAS 3840823 009760 C20H007 MANAGEMENT TCURS 1 CR 0.062 1.05 MANAGEMENT INSPECTION - ALL AREAS 840824 009766 C90K001 RB DATA ACCUISITION 1 OP 0.020 0.67 DATA ACQUISITION IN RB
  • 840824 009786 C90K001 RB DAT A* ACOUISITION 1 ES 0.022 0.67 DATA ACQUISITION IN RB 840824 009767 C80N001 RB WASTE REMOVAL 2 RP 0.307 4.22 TRASH REM 3 VAL / INSPECTION 8840824 009767 C80N001 RB WASTE REMOVAL 1 MM 0.165 1.95 TRASH REMOVAL / INSPECTION 840827 C09775 C70H001 RB RAD SURVEYS 3 HP 0.205 4.12 HP SURVEYS / JOB COVERAGE
  • 840827 009775 C70H001 RB RAD SURVEYS 5 CN 0.132 5.28 HP SURVEYS / JOB COVERAGE 840827 009777 C35N002 DOSE REDUCTION-347' 8 CN 0.899 14 27 SCABBLE, WET VACUUM AND PAINT FLOOR 840827 009789 C20H005 RB SUPP-0UTSIDE CTMT 24 CN 0.139 42.45 RB ENTRY SUPPORT-AIRLOCKS 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 110 CN 0.036 231.16 RB ENTRY SUPPORT-ANTEROOM 8840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.002 104.02 RB ENTRY SUPPORT-ANTEROCM
  • 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 1.05 RB ENTRY SUPPORT-ANTEROOM
  • 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 0.53 RB ENTRY SUPPORT-ANTEROOM

.*840827 009790 C20H005 RB SUPP-CUTSIDE CTMT 1 IC 0.000 0.53 RB E NTRY SUPPORT-ANTEROOM

  • 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 1.60 RB ENTRY SUPPORT-ANTER0OM 8840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 1.53 RB ENTRY SUPPORT-ANTEROOM

.=- DATE 022486 PAGE 57 Pr 0 56 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

,RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..........IVITY...............E.NTR........ E.... R E. M............................E.SCRIPTION ACT.... . COD . HOURS TASK D

  • .D. ATE..... NUMBER.NUMSER..........

. 27.95 REMOVE TRASH AND EQUIPMENT 840828 003793 C20H001 RB SUPPORT ACTIVITY 12 CN 1.552 840828 009794 C80N001 RB WASTE REMOVAL 2 MM 0.085 2.18 UNLOAD SKIP PAN / LOAD SCRAP IN WOOD BOXES

  • 840828 009794 C80N001 RB WASTE REMOVAL 3 OP 0.355 7.00 UNLOAD SKIP PAN / LOAD SCRAP IN WOOD BOXES 3840828 009794 C80N001 RB WASTE REMOVAL 2 IC 0.248 5.08 UNLOAD SKIP PAN / LOAD SCRAP IN WOCO BOXES s 40828 009794 C80N001 RB WASTE REMOVAL 1 RP 0.015 2.63 UNLOAD SKIP PAN / LOAD SCRAP IN WOOD BOXES
  • l40828 009794 C80N001 RB WASTE REMOVAL 1 CM 0.007 2.63 UNLOAD SKIP PAN / LOAD SCRAP IN WOOD BOXES 840828 009795 C50H001 RB P.M.

AND SURVEY 2 OP 0.191 3.07 MOVE SAND BAGS

  • 840522 009795 C50H001 RB P.M.

AND SURVEY I UM 0.067 1.45 MOVE SAND BAGS

  • S40828 009795 C50H001 R5 P M.

AND SURVEY Z IC 0.092 1.32 MOVE SAND SAGS 840828 009796 C20H007 MANAGEMENT TOURS 2 CM 0.187 2.25 PLACE TLD'S/SCABBLING INSPECTION

  • E40828 009796 C20H007 MANAGEMENT TOURS 1 CN 0.050 1.33 PLACE TLD'S/SCABBLING INSPECTION
  • S40828 009796 C20H007 MANAGEMENT TOURS 1 ES 0 155 1.63 PLACE TLD'S/SCABBLING INSPECTION 340829 009802 C20H007 MANAGEMENT TOURS 3 CN 0.170 3.08 BOARD OF DIRECTORS TOUR
  • 840829 009802 C20H007 MANAGEMENT TOURS 1 CR 0.061 1.00 BOARD OF DIRECTORS TOUR 840829 009803 C35N002 DOSE REDUCTION-347' 4 CN 0.182 4.73 MOVE MATERIALS AND EQUIPMENT 840829 009804 C35N002 DOSE REDUCTION-347*

12 CN 1.072 21.12 SCABBLE. WET VACUUM AND PAINT FLOOR 840829 009804 C35N002 DOSE REDUCTION-347' 4 CN 0.459 6.80 SCABBLE /WE T VAC & PAINT F LOOR-34 7 ' LEVEL l 840831 009812 C50H001 RB P.M AND SURVEY 2 CN 0.274 4.63 SLING INSPECTION 840831 009813 C35N002 DOSE REDUCTION-347* 9 CN 1.711 18.65 MOD IF Y 'D' RING LADDERS 840904 009818 C70H001 RB RAD SURVEYS 1 CN 0.046 0.70 ROUTINE'HP SURVEILLANCE & JOB COVERAGE e

  • 840904 009818 C70H001 RB RAD SURVEYS 3 HP 0.094 1.75 ROUTINE HP SURVEILLANCE & JOB COVERAGE

'd

  • E40904 009818 C70H001 RB RAD SURVEYS 1 CM 0.040 1.33 ROUTINE HP SURVEILLANCE & JOB COVERAGE N

640904 009819 C50H001 RB P.M. AND SURVEY 2 CN 0.104 2.45 RELOCATE ED&D TOOL IN RB E40904 009831 C20H005 RB SUPP-0UTSIDE CTMT 83 CN 0.029 216.97 RB ENTRY SUPPORT 840904 009831 C20H005 RB SUPP-OUTSIDE CTMT 11 HP 0.002 46.53 RB ENTRY SUPPORT 840904 009832 C20H005 RB SUPP-0UTSI9E CTMT 20 CN 0.146 38.72 RB ENTRY SUPPORT IN AIRLOCKS 840904 009840 C20H006 RB SAFETY INSPECTION 3 CN 0.201 4.08 TROUBLESHOOT POWER BUGGY 840905 009841 C20H006 RB SAFETY INSPECTION 3 CN 0.269 4.97 REPAIR POWER BUGGY 840905 009842 C80N001 RB WASTE REMOVAL 2 OP 0.151 4.80 REMOVE SCRAP FROM RB

  • 840905 009842 C80N001 RB WASTE REMOVAL 1 MM 0.017 2.25 REMOVE SCR AP FROM RB
  • S40905 009842 C80N001 RB WASTE REMOVAL 1 CM 0.141 2.52 REMOVE SCRAP FROM RB 840905 009843 C35N002 DOSE REDUCTION-347' 26 CN 2.552 49.40 SCABBLE/ WET VAC & PAINT FLOOR-347' LEVEL 840905 009845 C20H001 RB SUPPORT ACTIVITY 7 CN 0.924 15.83 REMOVE 5 TON HOIST / INSTALL MAN BASKET 840906 009849 C80N001 RB WASTE REMOVAL 2 MM 0.000 2.25 REMOVE TRASH FROM RB
  • 840906 009849 C80N001 RB WASTE REMOVAL 1 CM 0.035 1.23 REMOVE TRASH FROM RB l

840907 009854 C80N001 RB WASTE REMOVAL 1 RP 0.140 1.42 INSPECTIONS-ALL ELEVATIONS $40907 009859 C20H007 MANAGEMENT TOURS 2 CN 0.086 1.95 TECH PLANNING TOUR & INSPECTION d

  • 840907 009859 C20H007 MANAGEMLNT TOURS 1 ES 0.042 1.03 TECH PLANNING TOUR & INSPECTION l
  • S40907 009859 C20H007 MANAGEMENT TOURS 1 EG 0.032 1.00 TECH PLANNING TOUR & INSPECTION 340907 009860 C70H001 RB RAD SURVEYS 1 CN 0.090 2.63 TLD STUDY OF LOCA DUCTS & GENERAL AREA
  • 840907 009860 C70H001 RB RAD SURVEYS 1 OP 0.051 1.15 TLD STUDY OF LOCA DUCTS & GENERAL AREA

$840907 009860 C70H001 RB RAD SURVEYS 2 HP 0.198 4.00 TLD STUDY OF LOCA DUCTS & GENERAL AREA

  • 840907 009860 C70H001 RB RAD SURVEYS 2 ES 0.182 4.05 TLD STUDY OF LOCA DUCTS & GENERAL AREA 84a910 009865 C70H001 RB RAD SURVEYS 3 CN 0.102 2.05 CRANE & CANAL ROUTINE SURVEY / JOB COV.
  • 34v910 009865 C70H001 RB RAD SURVEYS 2 HP 0.035 0.82 CRANE & CANAL ROUTINE SURVEY / JOB COV.

840910 009876 C20H005 RB SUPP-0UTSIDE CTMT 103 CN 0.039 312.33 RB ENTRY SUPPORT

  • 840910 009876 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.000 34.43 RB ENTRY SUPPORT
  • 840910 009876 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.000 4.85 RB ENTRY SUPPORT
  • 840910 009876 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.001 1.33 RB ENTRY SUPPORT
  • 840910 009876 C20H005 RB SUPP-0UTSIDE CTMT 2 iti 0.001 2.78 RB ENTRY SUPPORT

l l DATE 022486 PAGE 58 I PNO 57 .TMI-2 UNC-DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMB E R. NUMBE.R..............IVITY

................ C ODE...,, R E M....... HOURS........................... S.C R I P T I O. N TASK DE ACT ENTR x......

  • 840910 009876 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0,001 1.60 RB ENTRY SUPPORT E840910 009876 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 1.55 RB ENTRY SUPPORT S40910 009877 C20H005 RB SUPP-0UTSIDE CTMT 25 CN 0.171 45.53 RB ENTRY SUPPORT IN AIRLOCKS 840913 009895 C35N002 DOSE REDUCTION-347' 14 CN 1.214 32.37 SCABBLE/ WET VAC & PAINT FLOOR-347' LEVEL 840913 009897 C20H002 RB - CCTV 2 IC 0.699 5.62 INSTALL RCS LEVEL MONITOR / ROUTINE MAINT

$840913 009897 C20H002 RB - CCTV 1 CN 0.447 2.87 INSTALL RCS LEVEL MONITOR / ROUTINE MAINT 840913 009903 C20H001 RB SUPPORT ACTIVITY 1 CN 0.083 2.12 CUT UP PLENUM MISTING SYSTEM 840913 009906 C80N001 RB WASTE REMOVAL 3 >#4 0.015 4.13 REMOVE SAND FROM RB

  • 840913 009906 C80N001 RB WASTE REMOVAL 4 OP 0.014 6.43 REMOVE SAND FROM RB

$840913 009906 C80N001 RB WASTE REMOVAL 1 CM 0.003 2.15 REMOVE SAND FROM RB 840914 009909 C70H001 RB RAD SURVEYS 1 CN 0.072 1.55 TLD STUDY OF LOCA DUCTS & GENERAL AREA

  • 840914 009909 C70H001 RB RAD SURVEYS 1 OP 0.088 1.47 TLD STUDY OF LOCA DUCTS & GENERAL AREA
  • 840914 009909 C70H001 RS RAD SURVEYS 1 ES 0.073 1.52 TLD STUDY OF LOCA DUCTS & GENERAL AREA 340917 009918 C20H006 RB SAFETY INSPECTION 1 AM 0.100 1,43 SAFETY INSPECTION-FUEL CANAL, O RINGS 2840917 009918 C20M006 RB SAFETY INSPECTION 2 CN 0.186 3.07 SAFETY INSPECTION-FUEL CANAL, O RINGS 840917 009919 C70H001 RB RAD SURVEYS 2 CN 0.089 1.03 CRANE & CANAL ROUTINE SURVEY / JOB COV

$840917 009919 C70H001 RB RAD SURVEYS 4 HP 0.292 6.35 CRANE & CANAL ROUTINE SURVEY / JOB COV 840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 90 CN 0.034 232.49 RB ENTRY SUPPORT 8840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 2 EL 0.000 3.47 RB ENTRY SUPPORT e

  • 840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.003 79.92 RB ENTRY SUPPORT i

'4

  • 840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 5 OP 0.002 10.53 RB ENTRY SUPPORT l

W $840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.62 RB ENTRY SUPPORT

  • 840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 3 MM 0.000 8.15 RB ENTRY SUPPORT
  • 840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.004 1.70 RB ENTRY SUPPORT 840917 009924 C20H005 RB SUPP-0UTSIDE CTMT 24 CN 0.226 45.48 RB ENTRY SUPPORT IN AIRLOCKS 840918 009935 C80N001 RB WASTE REMOVAL 1 EL 0.350 2.25 REBAG BROKEN BAGS / REMOVE FROM RB 3840918 009935 C80N001 RB WASTE REMOVAL 1 MM 0.315 2.22 REBAG BROKEN BAGS / REMOVE FROM RB 8840918 009935 C80N001 RB WASTE REMOVAL 1 OP 0.439 2.12 REBAG BROKEN BAGS / REMOVE FROM RB

$840918 009935 C80N001 RB WASTE REMOVAL 1 CM 0.496 2.12 REBAG BROKEN BAGS / REMOVE FROM RB 840919 009946 C20H007 MAhAGEMENT TOURS 1 f ti 0.198 1.57 TLD STUDY 3840919 009946 C20H007 MANAGEMENT TOURS 4 CN 0.492 4.65 TLD STUDY 840920 009951 C35N002 DOSE REDUCTION-347' 29 CN 2.687 54.37 SCABBLE/ WET VAC & PAINT FLOOR-347' LEVEL 840920 009952 C80N001 RB WASTE REMOVAL 2 RP 0.458 3.98 INSPECTION / BAG TRASH AND SAND 840924 009960 C20H005 RB SUPP-0UTSIDE CTMT 62 CN 0.030 178.95 RB ENTRY SUPPORT-ALL AREAS $840924 009960 C20H005 RB SUPP-0UTSIDE CTMT 5 HP 0.005 15.03 RB ENTRY SUPPORT-ALL AREAS I

  • 840924 009960 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.47 RB ENTRY SUPPORT-ALL AREAS l
  • 840924 009960 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.001 1.47 RB ENTRY SUPPORT-ALL AREAS 840924 009961 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.111 26.67 RB ENTRY SUPPORT IN AIRLOCKS 840924 009965 C70H001 RB RAD SURVEYS 3 CN 0.165 3.24 CRANE & CANAL ROUTINE SURVEY
  • 840924 009965 C70H001 RB RAD SURVEYS 1 HP 0.026 0.53 CRANE & CANAL ROUTINE SURVEY 840927 009991 C35N002 DOSE REDUCTION-347' 13 CN 0.874 17.88 STAGE WET VAC/ SCRUB FLOOR & PAINT 840927 009992 C20H002 RB - CCTV 2 IC 0.226 3.42 RE-MARK RCS LEVEL / TROUBLESHOOT CAMERA 8 840927 009993 C45H001 RB CORRECTIVE MAINT 4 EL 0.483 9.95 REPLACE OPERATOR ON AH-V-71 840927 009994 C35N002 DOSE REDUCTION-347 '

4 CN 0.138 5.37 RELOCATE MISC EQUIPMENT FOR SCABBLING i l 840927 009995 C20H001 RB SUPPORT ACTIVITY 1 OP 0.061 2.15 REMOVE DECON EQUIPMENT

  • 840927 009995 C20H001 RB SUPPORT ACTIVITY 1 CN 0.082 2.20 REMOVE DECON EQUIPMENT l

2840927 009995 C20H001 RB SUPPORT ACTIVITY 1 EL 0.095 2.13 REMOVE DECON EQUIPMENT i

  • 840927 009995 C20H001 RB SUPPORT ACTIVITY 2 CM 0.142 4.03 REMOVE DECON EQUIPMENT 840928 010001 C50H001 RB P M.

AND SURVEY 2 OP 0.508 3.75 OPERATIONS SURVEILLANCE 840928 010004 C90K001 RB DATA ACQUISITION 1 CN 0.011 0.52 LEAK CHECK SF-V-103 l l

~~ ~ DATE 022486 PAGE 59 PNO. 58 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RwP

.RWP ,EXP TRCK. PERS. DEPT. EXPOS. TIME ........ HOURS............ TASK DE.SCRIPTION............................... . REM ..... E. R. N UMBE R.....................I V I.T Y ENTR. CODE . NUMB ACT

  • DATE 2 CN 0.145 1.95 DECON INSPECTION 841001 010011 C20H007 MANAGEMENT TOURS 8841001 010011 C20H007 MANAGEMENT TOURS 1 RP 0.067 1.03 DECON INSPECTION 841001 010013 C70H001 RB RAD SURVEYS 5 HP 0.226 4.22 ROUTINE HP SURVE YS/ JOB COVER AGE 841001 010014 C35N003 DOSE REDUCTION-305*

19 CN 4.482 34.57 SCABBLE/ WET VAC/ SCRUB / PAINT FLOOR-305' 841001 010025 C20H005 RB SUPP-0UTSIDE CTMT 26 HP 0.u03 149.50 RB ENTRY SUPPORT-ALL AREAS

  • 841001 010025 C20H005 RB SUPP-0UTSIDE CTMT 77 CN 0.040 194.55 RB ENTRY SUPPORT-ALL AREAS 3841001 010025 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 2.33 RB ENTRY SUPPORT-ALL AREAS 841001 010026 C20H005 RS SUPP-0UTSIDE CTMT 20 CN 0.177 40.10 RB ENTRY SUPPORT IN AIRLOCKS 841004 010038 C80N001 RB WASTE REMOVAL 1 RP 0.020 0.53 REMOVE TRASH FROM RB 4841004 010038 C80N001 RB WASTE REMOVAL 1 EL 0.015 0.53 REMOVE TR ASH F ROM RB 841004 010039 C35N002 DOSE REDUCTION-347' 2 CN 0.053 1.23 PAINT FLOOR. PUMP STAND & TRIPOD STAND 841004 010041 C30A001 DECON POLAR CRANE 12 OP 1.418 27.78 DECON POLAR CRANE m841004 010041 C30A001 DECON POLAR CRANE 2 RP 0.162 4.20 DECON POLAR CRANE
  • 841004 010041 C30A001 DECON POLAR CRANE 3 EL 0.343 6.73 DECON POLAR CRANE
  • S41004 010041 C30A001 DECON POLAR CRANE 6 UM 0.676 13.63 DECON POLAR CRANE 2841004 010041 C30A001 DECON POLAR CRANE 4 MM 0.472 9.65 DECON POLAR CRANE

$841004 010041 C30A001 DECON POLAR CRANE 2 CM 0.184 4.63 DECON POLAR CRANE 841005 010045 C20HC01 RB SUPPORT ACTIVITY 1 RP 0.059 0.95 DECON INSPECTION-305* 347' & D RINGS e 841005 010047 C20H001 RB SUPPORT ACTIVITY 1 OP 0.039 0.82 IN-CONTAINMENT OPERATIONS SURVEILLANCE wa 841005 010048 C20H001 RB SUPPORT ACTIVITY 3 CN 0.541 5.25 INSTALL GANTRY CRANE RAIL SHIMS Jh 841005 010050 C35N003 DOSE REDUwTION-305' 8 CN 0.304 3.87 SCABBLE/ WET VAC/ SCRUB / PAINT FLOOR-305' s $41008 010054 C70H001 RB RAD SURVEYS 4 HP 0.512 8.20 ROUTINE HP SURVEYS / JOB COVERAGE 841005 010068 C20H005 RB SUPP-0UTSIDE CTMT 43 CN 0.012 117.95 RB ENTRY SUPPORT 3841008 010068 C20H005 RB SUPP-OUTSIDE CTMT 12 HP 0.000 56.35 RB ENTRY SUPPORT

  • 841008 010068 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 5.43 RB ENTRY SUPPORT
  • 841008 010068 C20H005 RB SUPP-0UTSIDE CTMT I EL 0.003 1.78 RB ENTRY SUPPORT
  • S41008 010068 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 1,77 RB ENTRY SUPPORT 841008 010069 C20H005 RB SUPP-0UTSIDE CTMT 9 CN 0.087 18.78 RB ENTRY SUPPORT IN AIRLOCKS 841011 010084 C80N001 RB WASTE REMOVAL 1 CN 0.000 2.55 REMOVE SAND AND WATER COLUMNS / INSPECTION
  • 841011 010084 C80N001 RB WASTE REMOVAL 1 OP 0.110 1.92 REMOVE SAND AND WATER COLUMNS / INSPECTION 8841011 010084 C80N001 RB WASTE REMOVAL 1 RP 0.130 1.93 REMOVE SAND AND WATER COLUMNS / INSPECTION 8841011 010084 C80N001 RB WASTE REMOVAL 1 UM 0.096 1.87 REMOVE SAND AND WATER COLUMNS / INSPECTION
  • 841011 010084 C80N001 RB WASTE REMOVAL 1 MM 0.088 1.60 REMOVE SAND AND WATER COLUMNS / INSPECTION 841017 010109 C20H005 RB SUPP-OUTSIDE CTHT 10 CN 0.077 17.57 RB ENTPY SUPPORT IN AIRLOCKS 841017 010110 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.002 37.85 RB ENTRY SUPPORT
  • S41017 010110 C20H005 RB SUPP-0UTSIDE CTMT 37 CN 0.019 111.92 RB ENTRY SUPPORT 841017 010111 C20H002 RB - CCTV 1 IC 0.031 1.18 REPAIR CAMERA 8 & 2 MULTIPLEX UNITS
  • 841017 010111 C20H002 RB - CCTV 1 CN 0.028 1.22 REPAIR CAMERA 8& 2 MULTIPLEX UNITS 841017 010115 C20H006 RB SAFETY INSPECTION 2 CN 0.192 3.97 SAFETY & HOUSEKEEPING INSPECTION
  • 841017 010115 C20H006 RB SAFETY INSPECTION 2 AM 0.188 3.37 SAFE TY & HOUSEKEE PING INSPECTION 841017 010116 C80N001 RB WASTE REMOVAL 2 OP 0.139 3.25 REMOVE CUT UP WATER COLUMNS 841017 010117 C20H007 MANAGEMENT TOURS 2 OP 0.139 2.53 PLACE TLD STRINGS-D RINGS & LOCA DUCTS 3841017 010117 C20H007 MANAGEMENT TOURS 3 CN 0.255 4.07 PLACE TLD STRINGS-D RINGS & LOCA DUCTS 841017 010118 C90K001 RB DATA ACQUISITION 1 CM 0.050 0.98 CONTAMINATION STUDY OF D RING HANDRAILS 841017 010119 C70H001 RB RAD SURVEYS 1 CN 0.059 1.03 ROUTINE HP SURVEYS / JOB COVERAGE

$841017 010119 C70H001 RB RAD SURVEYS 3 HP 0.145 2.94 ROUTINE HP SURVEYS / JOB COVERAGE 841019 010126 C20H006 RB SAFETY INSPECTION 4 CN 0.481 9.30 INSTALL TEMPORARY HANDRAIL 841022 010136 C80N001 RB WASTE REMOVAL 2 OP 0.203 3.90 REMOVE TURNBUCKLES FROM RB

  • 841022 010136 C80N001 RB WASTE REMOVAL 1 UM 0.078 2.05 REMOVE TURNBUCKLES FROM RB

$341022 010136 C80N001 RB WASTE REMOVAL 1 RP 0.139 1.90 REMOVE TURNBUChLES FROM RB l .J

- - - - - - -. - - _ _ ~.._ -.. . - - - _, - - ~ ~. DATE 022486 PAGE 60 PNO. 59 .TMI-2 UNC: DDS - ACTIVITY REPO'TT-REACTOR BUILDING DECONTAMINATION 286 D

  • RwP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME .................... REM . HOURS.,........................I.ON TASK DESCRIPT

  • ....E..NUMBE.R. NUMBER..............................
  • DAT ACTIVITY ENTR

. C. OD E 18 HP 0 000 88.68. RB ENTRY SUPPORT-ALL AREAS 841022 010139 C20H005.RB SUPP-0UTSIDE CTMT 8841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 3.27 RB ENTRY SUPPORT-ALL AREAS

  • 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 1 05 0.002 1.93 RB ENTRY SUPPGRT-ALL AREAS 3841022 010139 C20H005 RB SUPP-OUTSIDE CTMT 127 CN 0.069 393.30 RB ENTRY SUPPORT-ALL AREAS
  • 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 1 UT 0.000 2.52 RB ENTRY SUPPORT-ALL AREAS
  • 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.92 RB ENTRY SUPPORT-ALL AREAS 3841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 1 FH 0.000 2.63 RB ENTRY SUPPORT-ALL ARE AS 842022 010140 C20H005 RB SUPP-OUTSIDE CTMT 26 CN 0 206 54 02 RB ENTRY SUPPORT IN AIRLOCKS 841024 010161 C70H001 RB RAD SURVEYS 5 HP 0.620 6.40 ROUTINE HP SURVEYS / JOB COVERAGE J

841024 010163 C90h001 RB DATA ACQUISITION 9 CN 1.107 13.83 FLUG EQUIP HATCH / INSTALL ROBOT MNORAIL 841024 010166 C80N001 RB WASTE REMOVAL 2 IC 0.257 3.88 REMOVE SCR A P ME T AL & LUMBER FROM RB $841024 010166 C8CN001 RB WASTE REMOVAL 2 UM 0.278 3.83 REMOVE SCRAP METAL & LUMBER FROM RB $341024 010166 C8CN001 RB WASTE REMOVAL 1 RP 0.137 2.02 REMOVE SCRAP METAL & LUMBER FROM RB 841024 010167 C90k001 RB DATA ACQUISITION 2 CM 0.068 1.98 INSTALL & RETRIEVE TLDS-305' BY ELEVATOR

  • 841024 010167 C90K001 RB DATA ACQUISITION 1 ES 0.181 1.47 INSTALL & RETRIEVE TLDS-305' BY ELEVATOR 841025 010171 C90K001 RB DATA ACQUISITION 2 CN 0.050 1 42 P OWE R F OR ROBOTICS MONORAIL 841026 010176 090ko01 RB DATA ACQUISITION 1 UM 0.075 1.02 OBTAIN SCABBLE DUST & PAINT CHIP SAMPLES

$841026 010176 C90K001 RB DATA ACQUISITION 1 EL 0,109 1.00 OBTAIN SCABBLE DUST & PAINT CHIP SAMPLES 841027 010181 C30J001 RB DECON-347* ELEV 10 OP 0.931 20.02 HANDS ON DECON-347" TO 367' ELEVATIONS

  • 841027 010181 C30J001 RB DECON-347
  • ELEV 1 CN 0.095 1.90 HANDS ON DECvN-347' TO 367' ELEVATIONS d

a *841027 010181 C30J001 RB DECON-347' ELEV 2 EL 0.216 4.32 HANDS ON DECON-347' TO 367' ELEVATIONS %4 *841027 010181 C30J001 RB DECON-347' E LEV 1 CM 0.051 1.72 HANDS ON DECON-347' TO 367* ELEVATIONS UN 8841027 010181 C30J001 RB DECON-347* ELEV 1 RP 0.143 2.47 HANDS ON DECON-347* TO 367* ELEVATIONS s *841027 010181 C30J001 RB DECON-347' ELEV 2 UM 0.311 3.65 HANDS ON DECON-347* TO 367* ELEVATIONS 841029 010192 C20H005 RB SUPP-0UTSIDE CTMT 140 CN 0.061 443.91 RB E NTRY SUPPOR T-ALL ARE AS

  • 841029 010192 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.010 105.73 RB ENTRY SUPPORT-ALL AREAS
  • 841029 010192 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.003 1.22 RB ENTRY SUPPORT-ALL AREAS 3841029 010192 C20H005 RB SUPP-0UTSIDE CIMT 1 UT 0.000 2.22 RB ENTRY SUPPORT-ALL AREAS 3841029 010192 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 2.30 RB E NTRY SUPPORT-ALL ARE AS 841029 010193 C20H005 RB SUPP-0UTSIDE CTMT 36 CN 0.211 74.00 RB ENTRY SUPPORT IN AIRLOCKS 841030 010198 C90K001 RB DATA ACQUISITION 1 UM 0.025 0.57 CONTAMINATION STUDY OF D RING HANDRAILS 841030 010199 C80N001 RB WASTE REMOVAL 2 CM 0.152 4.07 REMOVE LCW RAD TRASH AND EQUIP, F ROM RB 841031 010205 C90K001 RB DATA ACQUISITION 8 CN 0.885 16.50 ROBOTICS POWER INSTALLATION 841031 101204 C70H001 RB RAD SURVE YS 6 HP 0.187 4 48 ROUTINE HP SURVEYS / JOB COVERAGE 841101 010209 C80N001 RB WASTE REMOVAL 2 RP 0.419 3.37 INSPECTION / BAG TRASH, TOOLS & EQUIP.

841105 010220 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.027 84.05 RB ENTRY SUPPORT-ALL AREAS

  • 841105 010220 C20H005 RB SUPP-0UTSIDE CTMT 132 CN O 054 408.88 RB ENTRY SUPPORT-ALL ARE AS

$841105 010220 C20H005 RB SUPP-CUTSIDE CTMT 5 OP 0.000 9.20 RB ENTRY SUPPORT-ALL AREAS

  • 841105 010220 C20H005 RB SUPP-0UTSIDE CTMT 5 RP 0.021 11.83 RB ENTRY SUPPORT-ALL AREAS 3841105 010220 C20H005 RB SUPP-0UTSIDE CTMT I SE 0.000 0.87 RB ENTRY SUPPORT-ALL AREAS
  • 841105 010220 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.000 2.13 RB ENTRY SUPPORT-ALL AREAS 841105 010221 C20H005 RB SUPP-0UTSIDE CTMT 32 CN 0.258 66 82 RB E NTRY SUPPORT IN AIRLOCKS 841106 010236 C35N003 DOSE REDUCT10N-305" 6 CN 1.666 12.43 INSTALL EQUIPMENT HATCH PLUGS-305" LEVEL
  • 841106 010236 C35N003 DOSE REDUCTION-305' 1 HP 0.201 1.87 INSTALL EQUIPMENT HATCH PLUGS-305' LEVEL 841106 010237 C90h001 RB DATA ACQUISITION 6 CN 1.335 16.87 LOAD TEST ROBOT MONORAIL 841106 010238 C90k001 RB DATA ACQUISITION 2 CN 0.386 4.57 INSTALL HATCH CAMER A FOR ROBOTICS 841106 010239 C30J001 RB DECON-347' ELEV 1 UM 0.112 2.20 HAMDS ON DECON-RC PUMP MOTOR STAND
  • 841106 010239 C30J001 RB DECON-347' ELEV 1 CN 0.091 2,18 HANDS ON DECON-RC PUMP MOTOR STAND 841107 010242 C8CN001 RB WASTE REMOVAL 1 RP 0.161 1.83 FILL & REMOVE WOODEN LSA BOXES 3841107 010242 C80N001 RB WASTE REMOVAL 1 EL 0.150 1.78 FILL & REMOVE WOODEN LSA 60XES

~ l l I l l DATE 022486 PAGE 61 PNO-60 .TMI-2 UNC: DDS - AC'.IVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • ....E... NUMBE.R. NUMB E.R..............IVIT.Y........

.....................HCURS.............. TASK DE.SCRIPTION................................

  • DAT ACT ENTR. CODE. REM
  • 841107 010242 C80N001 RB WASTE REMOVAL 1 CM 0.152 1.78 FILL & REMOVE WOODEN LSA BOXES 841107 010245 C80N001 RB WASTE REMOVAL 10 CN 1.448 25.90 CUT UP HATCH plugs FROM ELEVATOR SHAFT 841107 010248 C70H001 RB RAD SURVEYS 1 VI 0.064 1.20 ROUTINE HP SURVEYS / JOB COVERAGE 3841107 010248 C70H001 RB RAD SURVEYS 3 HP 0.269 4.07 ROUTINE HP SURVEYS / JOB COVERAGE

$841107 010248 C70H001 RB RAD SURVEYS 3 CN 0.055 1.62 ROUTINE HP SURVEYS / JOB COVERAGE 841107 010249 C80N001 RB WASTE REMOVAL 4 CN 0.723 8.97 CUT UP LE AD SHIELD DOLLIES 841108 010253 C90K001 RB DATA ACQUISITION 1 CN 0.111 1.47 STAGE ROBOT INTO RB 841108 010254 C90K001 RB DATA ACQUISITION 3 CN 0.220 3.33 STAGE RO6OT F LUSH UNIT IN CTMT 841108 010255 C90K001 RB DATA ACQUISITION 3 CN 0.333 5.35 MOVE ROBOT MONORAIL 841109 010261 C90K001 RB DATA ACQUISIT!ON 2 HP 0.425 4.57 VIDEO SURVEY / FLUSH ROBOT 2841109 010261 C90K001 RB DATA ACQUISITION 1 TC 0.045 1.13 VIDEO SURVEY / FLUSH ROBOT $841109 010261 C90K001 RB DATA ACOUISITION 7 CN 1.783 16.07 VIDEO SURVEY / FLUSH ROBOT 841113 010269 C80N001 RB WASTE REMOVAL 32 CN 2.488 68.35 CUT UP PLUGS USING OXY /ACETELENE 841113 010284 C20H005 RB SUPP-0UTSIDE CTMT 80 EN 0.028 232.42 RB ENTRY SUPPORT-ALL AREAS 3841113 010284 C20H005 RB SUrP-0UTSIDE CTMT 25 HP 0.020 149.68 RB ENTRY SUPPCRT-ALL AREAS

  • S41113 010284 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 4.20 PB ENTRY SUPPOR T-ALL ARE AS
  • $41113 010284 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 1.78 RB ENTRY SUPPORT-ALL AREAS 841113 010285 C20H005 RB SUPP-OUTSIDE CTMT 19 CN 0.191 42.53 RB EN!RY SUPPORT IN AIRLOCKS 841114 010289 C80N001 RB WASTE REMOVAL 17 CN 1.283 37.40 REMOVE AND DISMANTLE HATCH LIFT RIGS 841114 010291 C70H001 RB RAD SURVEYS 7 HP 0.572 7.27 ROUTINE HP SURVEYS / JOB COVERAGE q

841115 010295 C20H007 MANAGEMENT TOURS 1 CN 0.090 1.80 DECON INSPECTION Cm 841115 010296 C90K001 RB DATA ACQUISITION 7 CN 0.781 11.90 STAGE ROBOT / REMOTE SURVEV e *441115 010296 C90K001 RB DATA ACQUISITION 2 HP 0.278 3.52 STAGE ROBOT / REMOTE SURVEY 841115 010297 C80N001 RB WASTE REMOVAL 1 MM 0.075 2.03 REMOVE TRASH AND EMPTY GAS CYLINDERS E841115 010297 C80N001 RB WASTE REMOVAL 2 EL 0.056 3.12 REMOVE TRASH AND EMPTY GAS CYLINDERS s841115 010297 C80N001 RB WASTE REMOVAL 1 CM 0.037 1.07 REMOVE TRASH AND EMPTY GAS CYLINDERS 841115 010298 C30A001 DECON POLAR CRANE 2 OP 0.185 3.00 HANDS ON DECON OF POLAR CRANE 3841115 010298 C30A001 DECON POLAk CRANE 1 UM 0.063 1.48 HANDS ON DECON OF POLAR CRANE

  • 841115 010298 C30A001 DECON POLAR CRANF 1 CN 0.074 1.52 HANDS ON DECON OF POLAR CRANE 841119 010311 C20H006 RB SAFETY INSPECTION 1 AM

'0.070 1.53 SAFETY INSPECTION 8841119 010311 C20H006 RB SAFETY INSPECTION 3 CN 0.187 4.17 SAFETY INSPECTION 841119 010312 C20H005 RB SUPP-0UTSIDE CTMT 48 CN 0.009 140.98 RB E NTRY SUPPORT-ALL AREAS $841119 010312 C20H005 RB SUFP-0UTSIDE CTNT 13 HP 0.007 81.62 RB ENTRY SUPPORT-ALL AREAS 841119 010313 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.002 3.63 RB ENTRY SUPPORT IN AIRLOCKS $841119 010313 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.107 26.57 RB ENTRY SUPPOR T IN AIRLOCKS 841121 010333 C35N002 DOSE REDUCT10N-347' 5 CN 0.491 8.73 REMOVE SAND BAGS F ROM E AST LOCA DUCT 841127 010362 C20H005 RB SL'PP-OUTSIDE CTMT 23 CN 0.171 46.27 RB ENTRY SUPPORT IN AIRLOCKS 841127 010363 C20H005 RB SUPP-0UTSIDE CTMT 20 HP 0.003 87.80 RB ENTRY SUPPORT-ALL AREAS

  • 341127 010363 C20H005 RB SUPP-0UTSIDE CTMT 94 CN 0.016 270.65 RB ENTRY SUPPORT-ALL AREAS
  • 841127 010363 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 2.52 RB ENTRY SUPPOR T-ALL ARE AS
  • 841127 010363 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.88 RB ENTRY SUPPORT-ALL ARE AS

$341127 010363 C20H005 RB SUPP-OUTSIDE CTMT 1 CM 0.000 0.85 RB ENTRY SUPPORT-ALL AREAS 841124 010357 C70H001 RB RAD SURVEYS 4 CN 0.163 2.60 ROUTINE HP SURVEYS / JOB COVERAGE

  • 241128 010357 C70H001 RB RAD SURVEYS 2 HP 0.033 0.97 841123 010358 C80N001 RB WASTE REMOVAL 2 RP 0.308 3.50 INSPECTION FOR REMOVAL OF SCRAP METAL 841123 010359 C80N001 RB WASTE REMOVAL 5 CN 0.235 5.78 RIG HATCH PLUG AND LEF T RIG 841128 010360 C35N002 DOSE REDUCTION-347*

22 CN 1.589 41.70 SCABBLE. SCRUB. WET VAC & PAINT FLOOR 841130 010377 C90K001 RB DATA ACQUISITION 1 AM 0.125 1.50 CABLE INSPECTION 3541130 010377 C90K001 RB DATA ACQUISITION 1 CN 0.120 1.53 CABLE INSPECTION 8841130 010377 C90K001 RB DATA ACQUISITION 1 HP 0.101 1.53 CABLE INSPECTION l i

~ _. - ~ l l DATE 022486 PAGE 62 PNO. 61 .TMI-2 UNC-DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RwP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE...NUMSER. NUMBER...............

..........IVITY.......................... CODE,.............. HOURS.............,.............IPTION ACT ENTR . REM TASK DESCR .RB DATA ACQUISITION 1 ES 0.103 1.48. CABLE INSPECTION

  • 841130 010377 C90K001 841204 010397 C30E001 DECON RB D RINGS 3 CN 0.300 4.03 D RING TEMPORARY LIGHTING

$841204 010397 C30E001 DECON RB D RINGS 1 HP 0.195 1.38 D RING TEMPORARY LIGHTING 841204 010399 C30P001 DECON AIR COOLERS 1 RP 0.050 0.60 SAMPLE CONDENSATE *A&C* AIR COOLER SUMPS 3841204 010399 C30P001 DECON AIR COOLERS 1 CM 0.045 0.45 SAMPLE CONDENSATE ' A&C' AIR COOLER SUMPS 841204 010400 C80N001 RB WASTE REMOVAL 1 CM 0.053 1.08 REMOVE HIGH RAD TRASH-CFT

  • B*

TO AIRLOCK $341204 010400 C80N001 RB WASTE REMOVAL 1 OP 0.054 1.20 REMOVE HIGH R AD TR ASH-CF T 'B

  • TO AIRLOCK 841204 010402 C30J001 RB DECON-347' ELEV 1 OP 0.050 1.47 ROUTE NLB HOSES F ROM 305
  • TO 347' ELEV
  • 841204 010402 C30J001 RB DECON-347' ELEV 1 CN 0.083 1.47 ROUTE NLB HOSES FROM 305
  • TO 347' ELEV

$841204 010402 C30J001 RB DECON-347' ELEV 1 IC 0.101 1.52 ROUTE NLB HOSES FROM 305* TO 347* ELEV 841204 010405 C20H005 RB SUPP-0UTSIDE CTMT 26 HP 0.032 116.60 RB ENTRY SUPPORT-ALL AREAS

  • 341204 010405 C20H005 RB SUPP-0UTSIDE CTMT 156 CN 0.108 513.07 RB ENTRY SUPPORT-ALL ARE AS 2841204 010405 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.040 3.45 RB ENTRY SUPPORT-ALL AREAS 2841204 010405 C20H005 RB SUPP-0UTSIDE CTMT 3 RP 0.057 7.00 RB ENTRY SUPPORT-ALL AREAS
  • S41204 010405 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.047 0.85 RB ENTRY SUPPORT-ALL AREAS 841204 010406 C20H005 RB SUPP-0UTSIDE CTMT 37 CN 0.299 78.87 RB ENTRY SUPPORT IN AIRLOCKS 841205 010409 C30E002 DECON
  • A* D RING
  • 841205 010409 C30E002 DECON
  • A* D RING 2 OP 0.329 2.70 FLUSH
  • A* D RING 3 HP 0.474 4.73 FLUSH
  • A* D RING s :;841205 010409 C30E002 DECON
  • A' D RING 2 UM 0.439 3.23 FLUSH-JA* D RING

%4 *841205 010409 C30E002 DECON

  • A* O RING 1 IC 0.197 1.53 FLUSH
  • A* D RING
  • 4
  • 841205 010409 C30E002 DECON *A* D RING 1 MM 0.173 1.50 FLUSH
  • A* O RING e *841205 010409 C30E002 DECON
  • A*

O RING 1 CN 0.145 1.48 FLUSH

  • A* O RING 841205 010411 C35N002 DOSE REDUCTION-347' 4 CN 0.089 2.60 PAINT FLOOR - 347' ELEVATION 841205 010414 C70H001 RB RAD SURVEYS 2 CN 0.010 2.37 ROUTINE HP SURVEYS / JOB COVERAGE
  • 841205 010414 C70H001 RB RAD SURVtVS 5 HP 0.172 3.78 ROUTINE HP SURVEYS / JOB COVERAGE 841206 010417 C80N001 RB WASTE REMOVAL 4 OP 0.305 7.58 REMOVE SCRAP METAL FROM RB
  • 341206 010417 C80N001 RB WASTE RE.10 VAL 2 MM 0.423 5.03 REMOVE SCRAP ME TAL FROM RB 3841206 010417 C80N001 RB WASTE REMOVAL 1 CM 0,005 1.03 R E MOVE SC R A P ME T A L F R OM R B

$841206 010417 C80N001 RB WASTE REMOVAL 2 UM 0.038 2.08 REMOVE SCRAP METAL FROM RB 3341206 010417 C80N001 RB WASTE REMOVAL 1 IC 0.025 2.78 REMOVE SCRAP ME TAL FROM RB 841207 010422 C30E003 DECON

  • B' D RING 2 OP 0.339 3.82 FLUSH INSIDE OF
  • B* D RING FROM 367'ELEV
  • 841207 010422 C30E003 DECON *B* D RING 1 IC 0.159 2.18 FLUSH INSIDE OF
  • B* O RING FROM 367*ELEV
  • 341207 010422 C30E003 DECON
  • B' D RING 1 MM 0.146 1.60 FLUSH INSIDE OF
  • B* D RING FROM 367'ELEV 841207 010425 C30E002 DECON
  • A* D RING 1 CN 0.081 0.95 AIRBORNE CONTAMINATION CONTROL 841208 010428 C45H001 RB CORRECTIVE MAINT 2 MM 0.058 2.65 TECH SPEC SURVEILLANCE OF RB DOORS 841210 010432 C35N002 DOSE REDUCTION-347 '

5 CN 0.727 13.48 RIG SCABBLING DOST TO 305* ELEVATION 841211 010447 C80N001 RB WASTE REMOVAL 1 CM 0.253 2.18 REMOVE SCABBLE DUST F ROM RB 2841211 010447 C80N001 RB WASTE REMOVAL 2 OP 0.433 4.03 REMOVE SCABBLE DUST FROM RB 8841211 010447 C80N001 RB WASTE REMOVAL 1 UM 0.183 1.70 REMOVE SCABBLE DUST FROM RB 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 28 HP 0.119 111.38 RB ENTRY SUPPORT $841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 1 RW 0.020 3.95 RB ENTRY SUPPORT

  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 107 CN 0.039 354.99 RB ENTRY SUPPORT
  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 5 EL 0.036 3.97 RB ENTRY SUPPORT
  • s41211 010453 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.070 7.10 RB ENTRY SUPPORT
  • S41211 010453 C20H005 RB SUPP-OUTSIDE CTMT 2 OP 0.025 4.40 RB ENTRY SUPPORT 8841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 7 MM 0.070 18.67 RB ENTRY SUPPORT l
  • 841211 010453 C20H005 RR SUPP-0UTSIDE CTMT 3 IC 0.102 6.85 RB ENTRY SUPPORT 8841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 2 UM 0.025 6.12 RB ENTRY SUPPORT 841211 010454 C20H005 RB SUPP-0UTSIDE CTMT 30 CN 0.210 58.25 RB ENTRY SUPPORT IN AIRLOCKS 841212 010457 C35N002 DOSE REDUCTION-347' 2 CN 0.516 5.23 BAG SCABBLING DUST FOR REMOVAL

.m DATE 052286 PAGE 63 PNO. 62 RID 24 .TMI-2 UNC-DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .E XP TRCK. PERS. DEPT. EXPOS. TIME 4

  • DATE... NUMBER.NUMBE.R...........

..............IVITY............ .......... E. SC R I P T I O. NTASK D............................. ACT ..... CODE........RE.M..... HOURS......... ........ E.NTR t RB WASTE REMOVAL 5 CN 0.544 10.85 RIG 305* HATCHES TO 347' LEVEL t 841212 010458 C80N001 841212 010459 C70H001 RB RAD SURVEYS 4 HP 0.230 3.85 ROUTINE HP SURVEYS / JOB COVERAGE 841212 010462 C20H006 RB SAFETY INSPECTION 2 CN 0.203 3.82 SAF E T Y & HOUSE 8EE PING WALKDOWN 1 841213 010467 C35N003 DOSE REDUCTION-305* 6 CN 1.095 11.98 INST AL L HATCHE S - 305' LEVEL $841213 010467 C35N003 DOSE REDUCTION-305* 1 HP 0.260 2.35 INSTALL HATCHES - 305* LEVEL 841213 010469 C80N001 RB WASTE REMOVAL 1 RP 0.175 1.70 INSPECT FOR TRASH & BAG-305'&347* LEVELS 841213 010470 C45H001 RB CORRECTIVE MAINT 2 EL 0.155 3.37 REPLACE SOLEN 01D OPERATOR ON AH-Y-071

  • 841213 010470 C45H001 RB CORRECTIVE MAINT 1 CN 0.080 2.08 REPLACE SOLEN 0!D OPERATOR ON AH-Y-071 r

841214 010473 C80N001 RB WASTE REMOVAL 1 EL 0.075 2.52 REMOVE STUD STORAGE RACKS & MT GAS BILS. 3841214 010473 C80N001 RB WASTE REMOVAL 1 OP 0.091 2.55 R E MOVE STUD STOR AGE RACKS & MT GAS BILS. 341217 010485 C20H006 RB SAFETY INSPECTION 2 AM 0.095 1.65 SAF EIY & HOUSEKEE PING INSPECTION OF P.C. 8841217 010485 C20H006 RB SAFETY INSPECTION 1 CN O 050 0.97 SAFETY & HOUSEKEEPING INSPECTION OF P.C. 841218 010505 C30J001 RB DECOM-347' ELEV 2 RP 0.190 4.25 DECON INCORE INSTRUMENT TABLE $841218 010505 C30J001 RB DECON-347' ELEV 3 OP 0.454 6.77 DECON INCORE INSTRUMENT TABLE

  • 841218 010505 C30J001 RB DECON-347' ELEV 1 MM 0.144 1.55 DECON INCORE INSTRUMENT TABLE 841218 010509 C20H005 RB SUPP-0UTSIDE CTMT 13 HP 0.000 62.53 R8 ENTRY SUPPORT

$841218 010509 C20H005 RB SUPP-0UTSIDE CTMT 73 CN 0.038 248.53 RB ENTRY SUPPORT 8841218 010509 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.002 1.35 RB ENTRY SUPPORT 8841218 010509 C20H005 RB SUPP-OUTSIDE CTMT 1 IC 0.000 0.75 RB ENTRY SUPPORT

  • 841218 010509 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.001 2.22 PB ENTRY SUPPORT 8841218 010509 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.000 0.77 RB ENTRY SUPPORT 841218 010510 C20H005 RB SUPP-0UTSIDE CTMT 19 CN 0.225 44.03 RB ENTRY SUPPORT IN AIRLOCKS 841219 010513 C80N001 RB WASTE REMOVAL 7 CN 0.385 15.13 CUT UP 305* HATCHES AND REMOVE 841219 010515 C'0H001 RB RAD SURVEYS 2 HP 0.148 1.92 ROUTINE HP SURVEYS / JOB COVERAGE 2841219 010515 C70H001 RB RAD SURVEYS 1 CN 0.036 0.97 ROUTINE HP SURVEYS / JOB COVERAGE

'a 841220 010519 C20H002 RB - CCTV 3 IC 0.335 4.19 TROUBLESHOOT & REPAIR CAMERA 2 00 8841220 010519 C20H002 RB - CCTV 2 CN 0.322 2.93 TROUBLESHOOT & REPAIR CAMERA 2 a 841220 010522 C30C001 RB DECON-305* ELEV 18 CN ~ 419 35.35 RELOCATE MATERIAL / SUPPORT SCABBLING 841226 010545 C80N001 RB BASTE REMOVAL 4 CN 2.281 8.62 CUT UP AND REMOVE LEAD SHIELD DOLLIES 841226 010546 C80N001 RB BASTE REMOVAL 12 CN 0.880 25.28 CUT UP AND REMOVE 305* HATCHES 541226 010550 C20H005 RB SUPP-OUTSIDE CTMT 42 CN 0.020 138.83 RB ENTRY SUPPORT-ALL AREAS 3841226 010550 C20H005 RB SUPP-OUTSIDE CTMT 18 HP 0.005 115.40 RB ENTRY SUPPORT-ALL AREAS 4841226 010550 C20H005 RB SUPP-OuTSIDE CTMT 5 OP 0.000 633.00 RB ENTRY SUPPORT-ALL AREAS

  • 841226 010550 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 C.75 RB ENTRY SUPPORT-ALL AREAS
  • 441226 010550 C20H005 RR SUPP-0UTSIDE CTMT 1 MM 0.000 2.77 RB ENTRY SUPPORT-ALL AREAS 1

841226 010551 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.101 26.50 RB ENTRY SUPPORT IN AIRLOCKS t 841226 010552 C70H001 RB RAD SURVEYS 5 HP 0.330 6.18 ROUTINE HP SURVEYS / JOB COVERAGE 841227 010555 C30E003 DECON *B* D RING 2 CN 0.300 4.20 PLACE & RETRIEVE TLD STRING-367'D RING 841227 010559 C30C001 RB DECON-305

  • E LEV 4 CN 0.327 3.42 SCABBL E/WE T VAC/ PAINT FLOOR-305
  • LEVEL i

850102 010587 C20H005 RB SUPP-0UTSIDE CTMT 59 CN 0.006 176.68 RB ENTRY SUPPORT 8850102 010587 C20H005 RB SUPP-0UISIDE CTMT 14 HP 0.003 85.60 RB ENTRY SUPPORT

  • 850102 010587 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.000 0.90 RB ENTRY SUPPORT t
  • I50102 010587 C20H005 RB $UPP-0UTSIDE CTMT 1 OP 0.000 0.90 RB ENTRY SUPPORT 850102 010588 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.092 27.33 RB ENTRY SUPPORT IN AIRLOCKS 850103 010592 C80N001 RB WASTE REMOVAL 3 CN 0.240 7.15 CUT UP LEAD SHIELD DOLLIES-347' ELEV.

850103 010593 C30N001 RB WASTE REMOVAL 7 CN 0.488 12.40 CUT UP HAICH PLUGS-347' BURNING AREA 850103 010596 C30C001 RB DECCN-305

  • ELEV 2 CN 0.143 1.30 PAINT FLOOR AREA-2ONE 2 305' LEVEL 1

1 850104 010602 C30C001 RB DECON-305* ELEV 4 CN 0.608 5.13 RELOCATE MAT'l FOR SCABBLING-2ONE 3 TO 2 850107 010608 C30C001 RB DECOM-305* ELEV 16 CN 3.305 27.63 SCABBLE /WE T & DRY VAC/ PAINT ZCNE 3 850108 010626 C80N301 RB WASTE REMOVAL 2 CN 0.091 3.73 CUT UP LEAD 00LLIES 1 5

- ~ _. - - DATE 022486 PAGE 64 PNO. 63 .TMT-2 UNC-DDS - LCTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D x RWP .PWP .EXP TRCK. PERS. DEPT. EXPOS. TIME _ CODE.... R E M........ H O U R S... .........D E S.C.R I P T I O N

  • D. ATE... NUMBER. NUMBER........................CTIVITY

. ENIR A TASK l { 850108 010627 C80N001 RB NASTE REMOVAL 1 RP 0,157 1,58 INSPECT TRASH AND SCRAP FOR REMOVAL 850108 010628 C30E003 DEcoN

  • B* D RING 3 CN 0.425 5.88 PLACE & RETRIEVE TLD STRING-367'D RING 2850108 010628 C30E003 DECIN
  • B' D RING 1 FH 0.040 0.72 PLACE & RETRIEVE TLD STRING-367'O RING 2

4850108 010628 C30E003 DECC1

  • B' D RING 1 ES 0,204 2.77 PLACE & RETRIEVE TLD STRING-367'D RIN1 850109 010632 C20H007 MANAGEMENT TOURS 1 ES 0.195 1.28 INSPECT PENETS/ INSTALL & RETRIEVE TLDS 350109 010635 C20H005 RB SUPP-0UTSIDE CTMT 51 CN a.021 147.45 RB ENTRY SUPPORT 2850109 010635 C20H005 RS SLPP-0UTSIDE CTMT 11 HP o,004 69.72 RB ENTRY SUPPORT 8850109 010635 C20H005 RB SU*P-0UTSIDE CTMT 1 MM 0.005 1.18 RB ENTRY SUPPORT 8850109 010635 C20H005 RB SUPP-0UTSIDE CTHT 1 OP 0.005 1.20 RB ENTRY SUPPORT

$50109 010636 C20H005 RB SUFP-0UTSIDE CTMT 10 CN 0.069 17 97 RB ENTRY SUPPORT IN AIR,0CKS 850110 010643 C80N001 RB WA$ fE RE MOVAL 1 EL 0.049 1.47 RE MOVE HIGH RAD TR ASH F ROM UNDER CF T

  • 850110 010643 C80N001 RB WAS'E REMOVAL 1 CM 0.048 1.43 REMOVE HIGH RAD TRASH FROM UNDER CFT 850110 010644 C30J001 RB DECCM-347* ELEV 1 RP 0.078 1.90 LOW PRESSURE FLUSH OF INCORE INST. TABLE
  • S50110 010644 C30J001 RB DECC2-347' ELEV 2 CN 0 12; 1.87 LOW PRESSURE FLUSH OF INCORE INST. TABLE

$450110 010644 C30J001 RB DECO.!-347* ELEV 1 bM 0.135 1.83 LOW PRESSURE FLUSH OF INCORE INST. TABLE 850111 010649 C30E002 DECCN %* D RING 3 CN 1.329 3.25 APPLY F LUORE SCE NT TAPE TO ACCESS LADDER 850111 010651 C30J001 RB DEC0k-347' ELEV 4 CN 0.288 6.33 WET VAC/ SCRUB / PAINT-347' ELEVATION 850116 010680 C20H006 RB SAFET7 INSPECTION 3 CN 0.259 4.79 SAFE TY & HOUSEMEE PING INSPECTION 8850115 010680 C20H006 RB SAFETY INSPECTION 1 AM 0.072 1 68 SAFE TY & HOUSE KEE PING INSPECTION k *850116 010682 C35N003 DOSE REDLCTION-305* 6 CN 0.322 5,57 PAINT FLOOR-2ONE 3 AND WEST CATWALK 850116 010633 C70H001 RB RAD SUtvEYS 3 HP 0.306 5.22 ROUTINE HP SURVE YS/ JOB C0VERACE y3 850116 01068 3 C70H001 RB RAD SU2VEYS 2 CN 0.033 1.30 ROUTINE HP SURVEYS / JOB COVERAGE a 850116 010684 C20H002 RB - CCTV 3 IC 0.569 5.87 REPAIR CAMERA 2 850116 010685 C80N001 RB WASTE REMOVAL 1 EL 0.210 2.37 REMOVE SCRAP METAL & EMPTY GAS BOTTLES

  • 850116 010685 C80N001 RB WASTE REMOVAL 2 RP 0.265 4.67 REMOVE SCRAP METAL & EMPTY GAS BOTTLES 3850116 010685 C80N001 RB WASTE RLMOVAL 2 CM 0.074 3.97 REMOVE SCRAP METAL & EMPTY GAS BOTTLES 3850116 010685 C80N001 RB WASTE REMOVAL 2 OP 0.248 4.25 REMOVE SCRAP METAL & EMPTY GAS BOTTLES 850116 010685 C30F001 DECON PB CA.4AL 6 CN 0.161 10.87 HANDS ON DECON OF FUEL TRANSFER CANAL 850116 010690 C20H005 RB SUPP-0UTSIDE CTMT 10 HP 0.004 61.53 RB ENTRY SUPPORT
  • 850116 010690 C20H005 RB SUPP-0UTSIDE CTMT 83 CN 0.057 289 74 RB ENTRY SUPPORT 8850116 010690 C20H005 98 SUPP-0UTSIDE CTMT 1 OS 0.000 1.30 RB ENTRY SUPPORT 8850116 010690 C20H005 RB SUPP-0UTSIDE CTHT 1 OP 0.001 0.48 RB ENTRY SUPPORT 8850116 010690 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.003 3.40 RB ENTRY SUPPORT 850116 010691 C20H005 RB SUPP-0UTSIDE CTMT 23 CN 0.162 40.40 RB ENTRY SUPPORT IN AIRLOCKS I

850122 010724 C35N003 DOSE REDUCTION-305* 22 CN 3.052 50.70 SCABBLE/ WET VAC/ SCRUB FLOOR 850122 010727 C80N001 RB WASTE REMOVAL 1 RP 0.154 2.05 INSPECT FOR TRASH / BAG TRASH & EQUIPMENT 3850122 010727 C80N001 RB WASTE REMOVAL 1 CN 0.148 2.02 INSPECT FOR TR ASH / BAG TRASH & EQUIPMENT 850122 010728 C20H002 R B - CCT V 3 CN 0.343 3.75 RELOCATE CAMERA 2 850122 010730 C20H007 MANAGEMENT TOURS 2 CN 0.137 2.50 DECON INSPECTION & PHOTOGRAPHS

  • 850122 010730 C20H007 MANAGEME NT TOURS 2 RP 0.130 2.43 DECGN INSPECTION & PHOTOGRAPHS 850123 010733 C70H001 RB RAD SURVEYS 5 HP 0.169 3.48 ROUTINE HP SURVEYS / JOB COVERAGE 850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 5 OP 0.000 2.27 RB ENTRY SUPPORT 8850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 78 CN 0.025 236.96 RB ENTRY SUPPORT 8850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 6 HP 0.002 36.25 PB ENTRY SUPPORT
  • E50123 010738 C20H005 RB SUPP-0UTSIDE CTMT I EL 0 000 1.40 RB ENTRY SUPPORT 8850123 010738 C20h005 RB SUPP-OuTSIDE CTMT 1 RP 0.001 1.58 RB ENTRY SUPPORT
  • 850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.002 1.37 RB ENTRY SUPPORT 850123 010739 C20H005 RB SUPP-0UTSIDE CTMT 15 CN 0.099 29.25 RB ENTRY SUPPORT IN AIRLOCKS 850124 010742 C20H007 MANAGEVENT TOURS 1 HP 0.157 1.42 INSTALL & RETRIEVE TLD STRINGS 3850124 010742 C20H007 MANAGEMENT TCURS 2 CN 0.274 2.58 INSTALL & RETRIEVE TLD STRINGS

~. _ _ _ _ _ - _ - _ _ _ _ _ _ _ _. - - - ~ ~ - _ - _ - DATE 022486 PAGE 65 PNO 64 ,TMI-2 UNC* 005 - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RwP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME 3350124 010742 C20H007 MA NAGE ME NT TOURS 1 UM 0.045 0.75. ..................!04....................._. TASK DESCRIPT ..... HOURS....... l

  • DATE.. m eSE.R. NUMBER.................. C T.I V.I T Y.............. E.NTR. CODE..RE.M A

INSTALL & RETRIEVE TLD STRINGS 850125 010746 C35N003 DOSE REDUCTION-305' 2 CN 0.045 1.30 PAINT FLOOR ARE A IN ZONE 4 350125 010749 C80N001 RB WASTE REMOVAL 1 MM 0.072 1.68 REMOVE SCRAP WOOD & METAL FROM RB

  • S50125 010749 C80N001 RB WASTE REMOVAL 1 CM 0.129 1,67 REMOVE SCR AP WOOD & ME TAL FROM RB 850130 010774 C80h001 RB WASTE REMOVAL 1 MM 0.051 1.35 REMOVE SCR AP ME T AL F ROM R B s850130 010774 CSON001 RB WASTE REMOVAL 1 RP 0.050 1,40 REMOVE SCR AP ME TAL F ROM RB 8850130 010774 C80N001 RB WASTE REMOVAL 2 CM 0.218 3.15 REMOVE SCRAP ME TAL FROM RB 850130 010775 C70H001 RB RAD SURVEYS 4 HP 0.554 4 35 ROUTINE HP SURVEYS / JOB COVERAGE
  • 850130 010775 C70H001 RB R AD SURVE YS 1 CN 0.028 0.67 ROUTINE HP SURVEYS / JOB COVERAGE 850130 010779 C35NQQ3 DOSE REDDCTION-305*

6 CN 0.183 4.52 PAINT FLOOR AREA IN ZONE 4 850130 010780 C30E002 DECON

  • A* O RING 3 CN 0.598 5 38 OBTAIN BORON SAMPLE FROM *A*

OTSO/ FLUSH $350130 010780 C30E002 DECCN

  • A* D RING 1 RP 0.190 2.12 OBTAIN BORON SAMPLE FROM *A*

OTSG/ FLUSH 3850130 010780 C30E002 DECON

  • A* D RING 1 HP 0.075 1.18 OBTAIN BORON SAMPLE FROM *A*

OTSG/ FLUSH

  • 850130 010780 C30E002 DECON
  • A* D RING 2 OP 0.320 3.18 OBTAIN BORON SAMPLE FROM
  • A*

OTSG/ FLUSH 850130 010781 C20H005 RB SUPP-0UTSIDE CTMT 69 CN 0.016 183.58 RB ENTRY SUPPORT

  • 850130 010781 C20H005 RB SUPP-0UTSIDE CTMT 5 OP 0.000 2.90 RB ENTRY SUPPORT
  • I50130 010781 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.002 83.47 RB E NTRY SUPPOR T

$850130 010781 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 0.12 RB ENTRY SUPPORT 850130 010782 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.137 32.60 RB ENTRY SUPPORT IN AIRLDCKS

  • 850130 010752 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.005 1.55 RB ENTRY SUPPORT IN A!RLOCKS eC3 *350130 010732 C20H005 RB SUPP-OUTSIDE CTMT 1 RP 0.005 1.55 RB ENTRY SUPPORT IN AIRLOCKS C3 3850130 010742 C20H005 RB SUPP-0UTSIDE.CTMT 2 CM 0.005 1.98 RB ENTRY SUPPORT IN AIRLOCKS e

850204 010800 C80N001 RB WASTE REMOVAL 3 RP 0.344 4.42 INSPECTION / MOVE TRASH AND EQUIPMENT 8850204 010800 C80N001 RB WASTE REMOVAL 1 CM 0.020 1.25 INSPECTION / MOVE TRASH AND EQUIPMENT 850205 010818 C30C001 RB DECON-305* ELEV 4 CN 0.441 5.22 MOVE EQUIPMENT TO SUPPORT SCABBLING 850206 010827 C70H001 RB RAD SURVETS 5 HP 0.940 6.57 ROUT'NE HP SURVEYS / JOB COVERAGE 850206 010828 C20H006 RB SAFETY INSPECTION 2 CN 0.071 2.07 SAFETY & HOUSEKEEPING INSPECTION 850206 010833 C20H005 RB SUPP-0UTSIDE CTMT 19 CN 0.112 36.00 RB ENTRY SUPPORT IN AIRLOCKS 850206 010834 C20H005 RB SUPP-0UTSIDE CTMT 77 CN 0.015 239.22 RB ENTRY SUPPORT 3850206 010834 C20H005 28 SUPP-0UTSIDE CTMT 4 OP 0.006 4.33 RB ENTRY SUPPORT 8850206 010834 C20H005 RB SUPP-0UTSIDE CTMT 11 HP 0.003 68.83 RB ENTRY SUPPORT 8850206 010834 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0,000 1.08 RB ENTRY SUPPORT 850208 010840 C30C001 RB DECON-305* ELEV 2 CN 0.138 2.78 REMOVE DECON EQUIPMENT FROM RB 850208 010847 C50H001 RB P.M. AND SURVEY 2 IC 0.140 3.35 CALIBRATION CHECK RC-LT-102 LOOP 850208 010849 C20H007 MANAGEMENT TOURS 1 RP 0.031 0.85 DECON INSPECTION 850211 010853 C35N003 DOSE REDUCTION-305' 12 CN 0.630 11.68 BAG SCABBLING DEBRIS /SCABBLE/ PAINT 850212 010867 C30E002 DECON

  • A* O RING 9 CN 2.197 15.53 FLUSH COMPONENTS IN
  • A*

D RING 850212 010868 C20H007 MANAGEMENT TOURS 1 CN 0.078 0.87 DECON INSPECTION 850212 010870 C35N002 DOSE R E DUCTION-3 4 7

  • 2 CN 0.045 1.10 SHIELD TOP OF RC PUMP MOTOR STAND 850213 010876 C70H001 RB RAD SURVEYS 5 HP Q.194 4.68 ROUTINE HP SURVEYS / JOB COVERAGE 850213 010877 C20H007 MANAGEMENT TOURS 2 CN 0.337 4.97 DECON INSPECTION 850213 010880 C20H005 RB SUPP-OUTSIDE CTMT 16 CN 0.076 31.48 RB ENTRY SUPPORT IN AIRLOCKS 850213 010881 C20H005 RB SUPP-0UTSIDE CTMT 58 CN 0.035 161.53 RB ENTRY SUPPORT

$850213 010881 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.004 61.52 RB ENTRY SUPPORT E850213 010881 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.00n 1.37 RB ENTRY SUPPORT 850214 010887 C20H004 RB SPIDER 3 CN 0,423 9.75 SPIDER MAINTENANCE CHECK 850214 010890 C20H001 RB SUPPORT ACTIVITY 2 HP 0.048 1.48 REMOVE RX HEAD MONIT. SYS FOR CALIB. 850215 010895 C80N001 RB WASTE REMOVAL 1 OP 0.128 1.85 REMOVE SCABBLE DUST FROM RB 3850215 010895 C80N001 RB WASTE RE MOVAL 1 RP 0.143 1.78 REMOVE SCABBLE DUST FROM RB 850215 010896 C20H005 RS SUPP-0UTSIDE CTMT 1 OP 0.065 1.73 LOAD 55 GALLON DRUMS WITH SCABBLE DUST 1

~ - - - _ _ ~ -. - ~ - DATE 022486 PAGE 66 PNO. 65 .TMI-2 UNC: 005 - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER...............................................OURS...............................

ION ACTIVITY ENTR. CODE. REM .H TASK DESCRIPT

  • 850215 010896 C20H005 RB SUPP-0UTSIDE CTMT s....

1 CN 0.058. 1.78 LOAD 55 GALLON DRUMS WITH SCABBLE DUST 850215 010899 C20H002 RB - CCTV 2 IC 0.082 1.72 REPAIR CAMERA 1 PAN / TILT 850215 010900 C30E002 DECON 'A' D RING 3 CN 0.721 4 98 FLUSH PZR INTERNALS UNDER INSUL. PANELS 850218 010926 C20H005 RB SUPP-0UTSIDE CTMT 82 CN 0.030 273.05 RB ENTRY SUPPORT $850218 010926 C20H005 RB SUPP-0UTSIDE CTMT 16 HP 0.006 79.08 RB ENTRY SUPPORT 850218 010927 C20H005 RB SUPP-OUTSIDE CTMT 20 CN 0.109 41.13 RB ENTRY SUPPORT IN AIRLOCKS 550219 010908 C20H006 RB SAFETY INSPECTION 2 CN 0.194 3.35 SAFE TY & HOUSEKEE PING INSPECTION 8850219 010908 C20H006 RB SAFETY INSPECTION I AD 0.090 1.58 SAFE TY & HOUSEKEE PING INSPECTION 850219 010910 C70H001 RB RAD SURVEYS 3 CN 0.042 1.52 ROUTINE HP SURVEYS / JOB COVERAGE $850219 010S10 C70H001 RB RAD SURVEYS 1 HP 0.009 0.72 ROUTINE HP SURVEVS/ JOB COVERAGE 850220 010940 C35N003 DOSE REDUCTION-305* 3 CN 0.610 4,45 WALKDOWN SHIELD LOCATION FOR RB AIR CLR 850225 010960 C70H001 RB RAD SURVEYS 3 CN 0.157 6.97 ROUTINE HP SURVEYS / JOB COVERAGE

  • S50225 010960 C70H001 RB RAD SURVEYS S HP 0.117 4.85 ROUTINE HP SURVEYS / JOB COVERAGE 850225 010963 C30E002 DECON
  • A*

O RING 3 CN 0.697 6.78 FLUSH & DECON MIRROR INSULATION PANEL 350225 010964 C50H001 RB P.M AND SURVEY 3 CN 0.114 4,93 REBUILD U-5 SCABBLER 850225 010966 C20H001 RB SUPPORT ACTIVITY 3 CN 0.255 5.73 CONTAINMENT CLEANUP 850225 010967 C20H005 RB SUPP-0UTSIDE CTMT 28 HP 0,007 179.30 RB ENTRY SUPPORT 8850225 010967 C20H005 RB SUPP-OUTSIDE CTMT 5 OP 0.000 7.17 RB ENTRY SUPPORT e 3650225 010967 C20H005 RB SUPP-OUTSIDE CTMT 136 CN 0.038 414.48 RB ENTRY SUPPORT 00 *350225 010967 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 0.73 RB ENTPY SUPPORT 850225 010968 C20H005 RB SUPP-0UTSIDE CTMT 15 CN 0.094 29.82 RB ENTRY SUPPORT IN AIRLOCKS -d e 850226 010988 C90K001 RB DATA ACQUISITION 1 HP 0.151 1.68 INSTALL & RETRIEVE TLDS $850226 010988 C90K001 RB DATA ACQUISITION 1 CN 0.075 1.13 INSTALL & RETRIEVE TLDS 850226 010990 C30F001 DECON RB CANAL 4 CN 0.520 11.00 PUMP OUT FUEL ARRAY PIT 850226 010991 C30N001 RB WASTE REMOVAL 21 CN 1.209 45.40 CUT UP STUD STORAGE RACKS 350227 010997 C20H005 RB SUPP-0UTS EDE CTMT 24 CN 0.174 47.75 RB ENTRY SUPPORT IN AIRLOCKS 850227 010998 C35N002 DOSE REDUCTION-347' 9 CN 1.018 19.67 INSTALL SHIELDING-INCORE INST. TABLE 850301 011014 C20H006 RB SAFETY INSPECTION 3 CN 0.297 9.10 IDENTIFY SLINGS f 850301 011015 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.018 4.40 PREPARE WOODEN BOXES FOR SHIPMENT 850301 011016 C80N001 RB WASTE REMOVAL 1 OS 0.144 2.17 REMOVE SCR AP ME TAL FROM RB

  • S50301 011016 C40N001 RB WASTE REMOVAL 1 CN 0.143 2.17 REMOVE SCPAP METAL FROM RB 850301 011019 C20H001 RB SUPPORT ACTIVTTY 3 MM 0.086 2.73 000R SURVEILLANCE-EQUIPMENT HATCH 850302 O!!020 C20H001 RB SUPPORT ACTIVITY 3 CN 0.609 5.92 CONTAINMENT CLEANUP & HOUSEKEEPING 850302 011021 C30J001 RB DECON-347' ELEV 4 CN 0.387 9.48 DECON MAIN FH BRIDGE AF TER DISMANTLEMENT 850304 011024 C20H002 RB - CCTV 3 CN 0.384 4.63 INSTALL NEW RCS LEVEL CAMERA ON BEAM
  • 850304 011024 C20H002 RB - CCTV 3 IC 1.197 7.62 INSTALL NEW RCS LEVE L CAMER A CN BEAM 850304 011025 C20H002 RB - CCTV 1 EL 0.110 2.85 REPAIR POWER CABLE TO CAMERA 4
  • 350304 011025 C20H002 RB - CCTV 2 IC 0.245 5.83 REPAIR POWER CABLE TO CAMERA 4 850304 011027 C20H001 RB SUPPORT ACTIVITY 2 CN 0.239 4.67 GENERAL INSPECTION-ALL LEVELS 850304 011029 C70H001 RB RAD SURVEYS 3 HP 0.119 2.37 ROUTINE HP SURVE YS/ JOB COVERAGE 3850304 011029 C70H001 RB RAD SURVEYS 2 CN 0.039 1.40 ROUTINE HP SURVE YS/ JOB COVERAGE I

850304 011032 C20H005 RB SUPP-0UTSIDE CTMT 12 HP 0.010 69.00 RB ENTRY SUPPORT 8850304 011032 C20H005 RB SUPP-0UTSIDE CTMT 10 7 C N 0.053 357.98 RB ENTRY SUPPORT

  • S50304 011032 C20H005 RB SUPP-0UTSIDE CTMT 7 OP 0.004 8.53 RB ENTRY SUPPORT 8850304 011032 C20H005 RB SUPS-0UTSIDE CTMT 1 MM 0.000 0.67 RB ENTRY SUPPORT
  • 850304 011032 C20H005 RB SUPF-0UTSIDE CTMT 1 RP 0.002 4.45 RB ENTRY SUPPORT 850304 011033 C20H005 RB SUPP-0UTSIDE CTMT 30 CN 0.265 59.n5 RB ENTRY SUPPORT IN AIRLOCKS 550305 011047 C80N001 RB WASTE REMOVAL 1 OS 0.189 2.95 REMOVE LOW RAD TRASH AND SCRAP METAL 3850305 011047 C80N001 RB WASTE REMOVAL 2 OP 0.070 2.47 REMOVE LOW RAD TRASH AND SCRAP METAL
  • 850305 011047 C80N001 RB WASTE REMOVAL 2 CM 0.066 2.43 REMOVE LOW RAD TRASH AND SCRAP METAL

i l DATE 022486 PAGE 67 PNO. 66 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUT1 DING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ENTR TASK DESCRIPTION ............... CODE..RE.M..... HOURS

  • D. ATE... NUMBER. NUMBER....................I.VITY...........

ACT

  • 850305 011047 C80N001 RB WASTE REMOVAL 1 MM 0.230 2.73 REMOVE LOW RAD TRASH AND SCRAP METAL
  • 850305 011047 C80N001 RB WASTE REMOVAL 1 RP 0.205 2.93 REMOVE LOW RAD TRASH AND SCRAP METAL
  • 850305 011047 C80N001 RB WASTE REMOVAL 1 CN 0.250 2.73 REMOVE LOW R AD TR ASH AND SCR AP ME TAL 850306 011062 C30F001 DECON RB CANAL 8 CN 0.399 11.93 HIGH PRESSURE FLUSH OF FUEL STORAGE RACK 850308 011076 C20H001 RB SUPPORT ACTIVITY 4 CN 0.505 7 80 CONTAINMENT CLEANUP

$50308 011077 C80N001 RB WASTE REMOVAL 2 OP 0.031 5.90 REMOVE WOCDEN LSA BOXES 3850308 011077 C80N001 RB WASTE REMOVAL 1 RP 0.020 2.42 REMOVE WOODEN LSA BONES 3850308 011077 C80N001 RB WASTE REMOVAL e 1 CM 0.017 2.45 REMOVE WOODEN LSA BONES 850311 011082 C70H001 RB RAD SURVEYS 1 CN 0.008 0.28 ROUT!NE HP SURVEYS / JOB COVERAGE

  • 850311 011082 C70H001 RB RAD SURVEYS 4 HP 0.081 2.08 ROUTINE HP SURVEYS / JOB COVERAGE 850311 011083 C20H002 RB - CCTV 3 CN 0.494 5.27 MARK LEVEL INDICATOR BOARD-RCS CAMERA 850311 011088 C20H005 RB SUPP-0UTSIDE CTMT 17 HP 0.015 107.57 RB ENTRY SUPPORT
  • 850311 011088 C20H005 RB SUPP-0UTSIDE CTMT 133 CN 0.089 408.89 RB ENTRY SUPPOR T
  • S50311 011088 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.002 1.17 RB ENTRY SUPPORT 850311 011089 C20H005 RB SUPF.0UTSIDE CTMT 35 CN 0.236 67.88 RB ENTRY SUPPORT IN AIRLOCKS 850312 011103 C30J001 RB DECON-347' ELEV 2 CN 0.166 4.83 HANDS ON DECON OF MAIN FH BRIDGE 850313 011111 C30F001 DECON RB CANAL 5 CN 0.231 7.23 FLUSH FUEL RACK / HANDS ON DECON
  • 850313 011111 C30F001 DECON RB CANAL 1 HP 0.027 1.60 FLUSH FUE L RACK / HANDS ON DECON 850313 011114 C80N001 RB WASTE REMOVAL 2 OS 0.242 3.95 REMOVE TR ASH & ME TAL FROM 305
  • LEVEL
  • 850313 011114 C80N001 RB WASTE REMOVAL 3 OP 0.623 7.50 REMOVE' TRASH & ME TAL F ROM 305
  • LEVEL Co *850313 011114 C80N001 RB WASTE REMOVAL 2 CM 0.279 3.80 REMOVE TRASH & METAL FROM 305' LEVEL na *850313 011114 C80N001 RB WASTE REMOVAL 2 RP O.243 3.90 REMOVE TR ASH & ME T AL F ROM 305 ' LEVEL e

850313 011115 C20H005 RB SUPP-0UTSIDE CTMT 3 RP 0.044 7.75 REMOVE AND RELEASE LSA BOXES 3850313 011115 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.024 2.90 REMOVE AND RELEASE LSA BOXES 850313 011118 C20H001 RB SUPPORT ACTIVITY 1 RW 0.100 0.72 INSPECT ELECTRICAL CABLES-OPEN STAIRWELL 3850313 011118 C20H001 RB SUPPORT ACTIVITY I CN 0.102 0.73 INSPECT ELECTRICAL CABLES-OPEN STAIRWELL 850313 011124 C20H001 RB SUPPORT ACTIVITY 2 CN 0.150 4.20 INSPECT POWLR BUGGY FOR SAFETY 850314 011126 C20H001 RB SUPPORT ACTIVITY 1 CN 0.055 1.22 INSPECT IIF PROCESS HOSE 850315 011137 C20H001 RB SUPPORT ACTIVITY 2 CN 0,306 5.13 CONTAINMENT CLEANHP 850315 011140 C20H001 RB SUPPORT ACTIVITY 1 OP 0.089 1.68 INSPECT IIF PROCESS FLOW PATH 850318 011145 C30J001 RB DECON-347

  • ELEV 4 CN O.699 10.52 INSTALL WATER SUPPLY FOR KELLY VAC SYS.

850318 011146 C30J001 RB DECON-347' ELEV 20 CN 2.043 41.22 FLUSH CABLE TRAYS-E AST OF REFUEL CANAL 850318 011148 C70H001 RB RAD SURVEYS 3 HP 0.086 2.62 ROUTINE HP SURVEYS / JOB COVERAGE

  • 850318 011148 C70H001 RB RAD SURVEYS 2 CN 0.062 1.28 ROUTINE HP SURVEYS / JOB COVERAGE 850318 011153 C20H005 RB SUPP-0UTSIDE CTMT 41 CN 0.344 85.27 RB ENTRY SUPPORT IN AIRLOCKS 850318 011154 C20H005 RB SUPP-0UTSIDE CTMT 138 CN 0.063 449.86 RB ENTRY SUPPORT
  • 850318 011154 C20H005 RB SUPP-OUTSIDE CTMT 3 OP O.000 1.88 RB ENTRY SUPPORT
  • 850318 011154 C20H005 RB SUPP-OUTSIDE CTMT 23 HP 0.029 212.12 RB ENTRY SUPPORT
  • 850318 011154 C20H005 RB SUPP-0UTSICE CTMT 2 RP 0.002 3.87 RB ENTRY SUPPORT 850319 011165 C20H006 RB SAFETY INSPECTION 3 CN 0.248 4.32 SAFETY & HOUSEKEEPING INSPECTION 850320 011173 C90K001 RB DATA ACQUISITION 1 HP 0.055 0.85 REMOVE INSTRUMENTS F ROM ROBOT 850320 011174 C30F001 DECON RB CANAL 4 CN 0.291 7.10 INSTALL SCAFFOLD IN REFUEL CANAL i

850321 011182 C30J001 RB DECON-347' ELEV 14 CN 1.065 24.48 EQUIP STAGING / HOOKUP / EQUIP PROTECTION 850321 011183 C80N001 RB WASTE REMOVAL 3 OP 0.618 7.57 REMOVE TR ASH & SCR AP FROM 305

  • LEVEL
  • 850321 011183 C80N001 RB WASTE REMOVAL 2 CM 0.444 5.28 REMOVE TRASH & SCRAP FROM 305" LEVEL
  • 850321 011183 C80N001 RB WASTE REMOVAL 2 UM 0.382 4.45 REMOVE TRASH & SCR AP FROM 305' LEVEL
  • 850321 011183 C80N001 RB WASTE REMOVAL 4 RP 0.396 6.17 REMOVE TRASH & SCP AP F ROM 305
  • LEVE L 850321 011184 C20H005 RB SUPP-0UTSIDE CTMT I MM 0.011 2.68 REMOVE AND RELEASE LSA BOXES
  • 850321 011184 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.018 2.57 REMOVE AND RELEASE LSA BOXES
  • 850321 011184 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.029 5.03 REMOVE AND RELEASE LSA BOXES i

1

~ _ _ _ DATE 022486 PAGE 68 PNO. 67 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .E XP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER..........................IVITY ACT ENTR. CODE.. REM.......

H.OURS.............T.AS.K DESCRIPTION 4850321 011184 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.038..... 5 35 REMOVE AND RELEASE LSA BOXES 850321 011187 C20H001 R8 SUPPORT ACTIVITY 2 CN 0.097 2.10 REMOVE RAIL STOP STUDS BY GRINDING 850321 011188 C30E006 MEAS. FUEL-LOWER RV 14 CN 2.725 40.41 INCORE PROBE OF MAT'L IN RX VESSEL

  • S50321 011188 C30E006 MEAS. FUEL-LOWER RV 1 HP 0.233 3.12 INCORE PROBE OF MAT't IF RX VESSEL 850322 011193 C20H001 RB SUPPORT ACTIVITY 4 CN 0.245 5.52 GENERAL INSPECTION 850325 011196 C70H001 RB RAD SURVEYS 4 HP 0.268 5.67 ROUTINE HP SURVEYS / JOB COVERAGE
  • 850325 011196 C70H001 RB RAD SURVEYS 1 CN 0.055 1.00 ROUTINE HP SURVEYS / JOB COVERAGE 850325 011199 C20H001 RB SUPPORT ACTIVITY 3 CN 0.234 5.50 CONTAINMENT CLE ANUP-FUE L CANAL 850325 011200 C20H002 R8 - CCTV 1 CN 0.150 2.77 REPAIR POWER CABLE TO CAMERA 4
  • 850325 011200 C20H002 R8 - CCTV 1 UM 0.098 2.70 REPAIR POWER CABLE TO CAMERA 4
  • 850325 011200 C20H002 R8 - CCTV 1 IC 0.165 2.83 REPAIR POWER CABLE TO CAMERA 4 850325 011201 C30F001 DECON RB CANAL 10 CN 0.790 22.05 FILL DRUM / MOVE TO CABLE TRAY / FLUSH TRAY 850325 011202 C30F001 DECON RB CANAL 40 CN 1.470 76.02 STAGE EQUIP / HOOK UP KELLY / FLUSH CANAL 850325 011203 C20H001 R8 SUPPORT ACTIVITY 4 CN 0.551 10.45 REMOVE & PLACE SHIELDING-MISSILE SHIELDS 850325 011219 C20H005 RB SUPP-0UTSIDE CTMT 35 CN 0.193 67.48 RB ENTRY SUPPORT IN AIRLOCKS 850325 011220 C20H005 RB SUPP-0UTSIDE CTMT 125 GN 0.047 432.33 RB ENIRY SUPPORT
  • 850325 011220 C20H005 RB SUPP-0UTSIDE CTMT 17 HP 0.007 123.92 RB ENTRY SUPPORT
  • 850325 011220 C20H005 RB SUPP-0UTSIDE CTMT I RP 0.000 0,37 R8 ENTRY SUPPORT 850326 011225 C80N001 R8 WASTE REMOVAL 2 OP 0.305 5.60 REMOVE TRASH AND SCRAP METAL
  • 850326 011225 C80N001 RB WASTE REMOVAL 1 CM 0.180 2.77 REMOVE 4 RASH AND SCRAP METAL

,co 850326 011226 C20H005 RS SUPP-GUTSIDE CTMT 1 OP 0.013 2.70 REMOVE TRASH AND MISC. SCRAP METAL La *850326 011226 C20 HOG 5 RB SUPP-0UTSIDE CTMT 1 MM 0.010 2.70 REMOVE TRASH AND MISC. SCRAP METAL I 850326 011233 C20H001 R8 SUPPORT ACTIVITY 2 CN 0.103 3.53 GEN INSPECTION-P.C. LOAD TEST AUX HOOK 850327 O!!232 C20H006 R8 SAFETY INSPECTION 1 AD 0.080 1.88 SAFETY & HOUSEKEEPING INSPECTION

  • 850327 011232 C20H006 RB SAFETY INSPECTION 1 CN 0.074 2.13 SAFE TY & HOUSEKEE PING INSPECTION
  • 850327 011232 C20H006 RB SAFETY INSPECTION 1 HP 0.100 1.87 SAFETY & HOUSEKEEPING INSPECTION 850327 011234 C45H001 RB CORRECTIVE MAINT 2 EL 0.025 1.42 TROUBLESHOOT / REPLACE BREAKER-POWER BUGGY 850328 O!!240 C20H002 RB - CCTV 2 IC 0.276 2.38 REPAIR RCS LEVEL CAMERA / CHECK CONTROLS 850328 011241 C30C001 RB DECON-305* ELEV 3 CN 0.200 4.53 SCRUB & WET VAC FLOOR USING TRITON 100 850328 011243 C20H001 RB SUPPORT ACTIVITY 2 CN 0.115 3.38 VERIFY HOLE LAYOUT-DWCS VALV MANIFOLD 850329 011249 C20H006 RB SAFETY INSPECTION 2 AD 0.740 2.13 SAFETY & HOUSEKEE PING INSPECTION
  • 850329 011249 C20H006 RB SAFETY INSPECTION 1 HP 0.350 1.03 SAFETY & HOUSEKEEPING INSPECTION

'. GRAND-TOTAL - PERS ENTR. 21526 . EXPOS REM . 666.18600 TIME HOURS 60822.060 END REPORT I

4.0 COMPUTER REPORTS 4.4 Activity Report - Reactor Building Decontamination (individual work activities)

DATE 022486 PAGE 2 PNO 1 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR CUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER. NUMBER

.......... I. V I T Y...... _...... _. E N T R ACT .HCURS 810522 001111 C20G003 DECON EXP-DATA ACQUI. ....... CODE........ R E.M .......... TASK DESCRIPTION 2...................... 5 CN 0.100 10.00 . MOCK-UP GAMMA SPECTROME TER .SUB70TAL - EXP TRCK NUMBER = C200003 PERS ENTR 5 EXPOS REM 0.1000000 . TIME HOURS 10.000000 800321 081772 C20H001 RE SUPPORT ACTIVITY 5 CN 0.075 5.68 SAMPLE GLOVEBOX AIR 800327 081869 C20H001 R8 SUPPORT ACTIVITY 2 CR 0.090 2.75 CONTAINMcNT ENTRY TEAM TRAINING

  • 800327 081869 C20H001 RB SUPPORT ACTIVITY 2 CN 0.130 3.42 CONTAINMENT ENTRY TEAM TRAINING
  • 800327 081869 C20H001 R8 SUPPORT ACTIVITY 1 ES 0.065 1.50 CONTAINMENT E N1RY TE AM TR AINING
  • 800327 081869 C20H001 RB SUPPORT ACTIVITY I OP 3.090 1.25 CONTAINMENT ENTRY TEAM TRAINING
  • 800327 081869 C20H001 RB SUPPORT ACTIVITY I VI 0.040 1.25 CONI AINME NT ENTRY TEAM TRAINING 800331 081960 C20H001 R8 SUPPORT ACTIVIT) 2 CR 0.165 2.50 SURVEY F OR CAV'4INMENT E NTRY TEAM

$800331 081960 C20H001 RB SUPPORT ACTIVITY 1 ES 0.120 1.25 SURVEY FOR ( 'INMENT ENTRY lEAM

  • 800331 081960 C20H001 RB SUPPORT ACT!VITY 1 V!

0.085 1.50 SURVEY FOR ,1 NME N T E N T R Y TEAM

  • 800331 081960 C20H001 RB SUPPORT ACTIVITY 1 CN 0.100 1.25 SURVEY FOR LC.. AINMENT E N1R Y TEAM 800331 081972 C20H001 R B St'*."CR T ACT IVI T Y 1 GP 0.000 0.50 OBTAIN RB SUMP LEVEL READING

$800331 081972 C20H001 RB SUPPLJT ACTIVITY 2 CN 0.000 1.00 OBTAIN RB SUMP LEVEL READING 800403 082061 C20H001 R8 SU PORT ACTIVITY 1 CR 0.006 3.62 SAMPLE CONTAINMENT AIR / TEST MONIT EQUIP $800403 082061 C20H001 RB SUPPORT ACTIVITY 4 CN 0.030 12.25 SAMPLE CONTAINMENT AIR / TEST MONIT EQUIP 800408 082139 C20H001 RB SUPPORT ACTIVITY 2 CN c.000 0.83 INSPECT-FOR R8 EMERGENCY EXIT 800411 0B2236 C20H001 RB SUPPORT ACTIVITY 1 CR U.000 1.17 SE T UP EMERGENCY EXIT AREA 00 *800411 082236 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 5.33 SET UP EMERGENCY EXIT AREA U1 800422 082501 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 1.50 START AIRLOCK PURGE-PREP FOR REENTRY 800424 0B2557 C204001 RD SUPPORT ACTIVITY 4 CN 0.000 17.08 INSTALL AIRLOCK ALARM BELL 800519 083125 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.50 PREPARE EMERGENCY EXIT AREA

  • 800519 083125 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 1.67 PREPARE EMERGENCY EXIT AREA
  • 800519 083125 C20H001 RB SUPPORT ACTIVITY 2 CR 0.000 1.00 PREPARE EMERGENCY EXIT AREA 800519 0B3127 C20H001 RB SVPPORT ACTIVITY 3 CN 0.000 6.48 INSEPT ANTENNA INTO CONTAINMENT 800520 0B3124 C20HG01 RB SUPPORT ACTIVITY 10 CM J.032 25.37 RB SURVE ILLANCE AND SUPPORT
  • 800520 083124 C20H001 RB SUPPORT ACTIVITY 7 CR 0.019 11.08 RB SURVEILLANCE AND SUPPORT
  • 800520 083124 C20H001 RB SUPPORT ACTIVITY

! ES 0.009 1.50 RB SUPVEILLANCE AND SUPPORT

  • 800520 083124 C20MG01 R8 SUPPORT ACTIVITY 1 OP 0.000 7.50 RB SURVEILLANCE AND SUPPORT
  • 800520 CP1124 C20H001 RB SUFPO.RT ACTIVITY 2 VI 0.010 2.57 RB SURVEILLANCE AND SUPPORT 800520 083107 C2CHOG1 RB SUPPORT ACTIVITY 1 CN 0.005 1.00 CHECK OR REPAIR ANTENNA 800520 083158 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 4.00 TRANSFER REENTRY SAMPLES FOR At:A LYSi%

800520 0B3174 C20H001 RB SUPPORT ACTIVITY 4 CR 6.015 1.33 REESTABLISH ARLK OPERABILITY / LEAK TEST $800520 083174 C20H001 RB SUPPORT ACTTVITY 1 MM 0.005 0.75 REESTABLISH ARLK OPERABILITY / LEAK TEST

  • 800520 083174 C20H001 RB SUPPORT ACTI%ITY 1 VI 0.005 1.17 REESTABLISH ARLK OPERABILITY / LEAK TEST
  • 800520 OP)174 C20H001 R8 SUPPORT ACTIVITY 3 CN 0.027 1.00 REESTABLISH ARLK OPERABILITY / LEAK TEST 800522 083216 C20H001 RB SUPPORT ACTIVITY 2 CN 0.003 0.67 SURVEILLANCE OF PERSONNEL AIRLOCK 800523 0E7243 C20H001 R8 SUPPORT ACTIVITY 1 CN 0.001 0.50 AIRLOCK C00R INSPECT!ON 8800523 083243 C20H001 RB SUPPORT ACTIVITY 1 HP 0.001 0.50 AIRLOCK DOGk INSPECTION 4800523 303243 C20h001 RB SUPPOR1 ACTIVITY 2 CR 0.010 1.00 AIRLOCK DOOR INSPECTION 800523 083245 C20He01 RB SUPPORT ACTIVITY I OP 0.015 0.85 INSPECTION / TEST!NG - DOCR MAINTENANCE
  • 800523 083245 C20H001 R8 SUPPORT ACTIVITY 1 EL C.006 0.85 INSPECTION / TESTING - DOOR MA t h1 E N A NCE
  • 800523 083245 C20H001 R8 SUPPORT ACTIVITY 3 CN 0.005 1.33 INLPECTION/ TESTING - DOOR MAINTENANCE 300527 083286 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 1.00 VISUAL INSPECTION - AI* LOCK INNER DOGR 800530 083380 C20H001 R8 SUPPORT ACTIVITY 5 CR 0.056 7.17 OPERATIONAL TEST - AIRLOL: INNER 000R
  • s00530 083380 C20H001 RB SUPPORI ACTIVITY 4 CN 0.029 11.28 OPERATIONAL TEST - AIRLOCK INNER DOOR
  • 800530 083380 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 1 52 OPERA!!ONAL TEST - AIRLOCK If!NER 000R

DATE 022486 PAGE 3 PNO. 2 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME . CODE. REM . HOURS TASK DESCRIPTION

  • DATE...NUMBE.R. NUMBER.........,............................ENTR ACTIVITY RB SUPPORT ACTIVITY
  • 800530 083380 C20H001 2 ES

. 0.040. 4.45 . OPERATIONAL TEST - AIRLOCK INNER 000R

  • 800530 083380 C20H001 RB SUPPORT ACTIVITY 2 EL 0.033 4.47 OPERATIONAL TEST - AIRLOCK INNER DOOR 800604 083480 C20H001 RB SUPPORT ACTIVITY 1 VI 0.020 2.50 HOOK UP RB SAMPLE PUMP 800623 083843 C20H001 RB SUPPORT ACTIVITY 2 CN 0.015 2.13 PROVIDE POWER RECEPTACLES IN AIRLOCK
  • 800623 083843 C20H001 RB SUPPORT ACTIVITY 3 MM 0.032 1.33 PROVIDE POWER RECEPTACLES IN AIRLOCK
  • 800623 083843 C20H001 RB SUPPORT ACTIVITY 2 ES 0.004 2.33 PROVIDE POWER RECEPTACLES IN AIRLOCK
  • 200623 083843 C20H00i RB SUPPORT ACTIVITY 1 EL 0.010 1.33 PROVIDE POWER RECEPTACLES IN AIRLOCK 800624 083868 C20H001 RB SUPPORT ACTIVITY 4 MM 0.111 4.42 PREP FOR DRILLING HOLES IN AIRLOCK 000R
  • 800624 083868 C20H001 RB SUPPORT ACTIVITY 1 EL 0.010 0.58 PREP FOR DRILLING HOLES IN AIRLOCK 000R
  • 800624 083868 C20H001 RB SUPPORT ACTIVITY 1 ES 0.002 0.03 PREP FOR DRILLING HOLES IN AIRLOCK DOOR
  • 800624 003868 C20H001 RB SUPPORT ACTIVITY 1 CN 0.015 1.58 PREP FOR DRILLING HOLES IN AIRLOCK DOOR 500630 0B3960 C20H001 RB SUPPORT ACTIVITY 3 FH 0.133 4.50 PREP & DRILL ARLK WALL / REPAIR INNEP LATCH
  • 800630 083960 C20H001 RB SUPPORT ACTIVITY 1 ES 0.000 1.50 PREP & DRILL ARLK WALL / REPAIR INNER LATCH
  • 800630 083960 c20H001 RB SUPPORT ACTIVITY 1 CN 0.005 1.95 PREP & DRILL ARLK WALL / REPAIR INNER LATCH 800701 083983 C20H001 RB SUPPORT ACTIVITY 3 FH 0.055 4.50 PREP &D4ILL ARLK WALL / REPAIR INNER LATCH
  • 800701 083983 C20H001 RB SUPPORT ACTIVITY 1 ES 0.002 1.83 PREP & DRILL ARLK WALL / REPAIR INNER LATCH
  • 800701 083983 C20H001 RB SUPPORT ACTIVITY 2 CN 0.017 6.25 PREP & DRILL ARLK WALL / REPAIR INNER LATCH 801016 085325 C20H001 RB SUPPORT ACTIVITY 4 OP 0.010 2.92 DECON& LEAK RATE TEST ARLK 2 & ANTER0OM 2801016 085325 C20H001 R8 SUPPORT ACTIVITY 2 CN 0.015 3.08 DECON& LEAK RATE TEST ARLK 2 & ANTEROOM 8801016 085325 C20H001 RB SUPPORT ACTIVITY 2 CR 0.050 2.00 DECON& LEAK RATE TEST ARLK 2 & ANTEROOM 8 5 RB SUPPORT ACTIVITY 1 HP 0.000 0.22 DECON& LEAK RATE TEST ARLK 2 & ANTER0OM

@$*801016085325C20H001 801016 085326 C20H001 RB SUPPORT ACTIVITY 2 HP 0.020 5.00 DECON AND LEAK RATE TEST AIRLOCK NO. 1 801016 085326 C20H001 RB SUPPORT ACTIVITY 9 OP O.052 14.73 DECON AND LEAK RATE TEST AIRLOCK NO. 1 801017 085327 C20H001 RB SUPPORT ACTIVITY 2 HP 0.015 4.08 DECON AS REQUIRED AFTER ENTRY

  • 801017 085327 C20H001 RB SUPPORT ACTIVITY 4 CN 0.045 9.08 DECON AS REQUIRED AFTER ENTRY 801117 085600 C20H001 RB SUPPORT ACTIVITY 2 CR 0.000 6.17 DECON ANTEROOM
  • 801117 085600 C20H001 RB SUPPORT ACTIVITY I CN 0.000 3.00 DECON ANTEROOM 810204 000313 C20H001 RB SUPPORT ACTIVITY 2 CR 0.020 5.58 DECON ANTEROOM
  • 810204 000313 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 4.25 DECON ANTEROOM 810317 000694 C20H001 RB SUPPORT ACTIVITY 2 HP 0.010 6.83 HP COVERAGE & ENTRY 7 SUPPORT
  • 810317 000694 C20H001 RB SUPPORT ACTIVITY 8 CN 0.030 27.64 HP COVERAGE & ENTRY 7 SUPPORT 810317 000695 C20H001 RB SUPPORT ACTIVITY 2 CN 0.020 1.25 TRANSFER PB WATER SAMPLES
  • 810317 000695 C20H001 RB SUPPORT ACTIVITY 2 CR 0.010 1.17 TRANSFER RB WATER SAMPL E S 810317 000696 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.83 DOOR SEAL TEST - PERSONNEL AIRLOCK 810408 000852 C20H001 RB SUPPORT ACTIVITY 2 OP 0.005 2.50 ANTC.00M SUPPORT F OR RB ENTRY 8
  • 810408 000852 C20H001 RB SUPPORT ACTIVITY 5 CN 0.018 9.12 ANTEROOM SUPPORT FOR RB ENTRY 8 810430 000985 C20H001 RB SUPPORT ACTIVITY 4 CN 0.016 14.33 ANTERDOM SUPPORT FOR RB ENTRY 9 810514 001057 C20H001 RB SUPPORT ACTIVITY I AD 0.000 1.42 ANTEROOM SUPPORT FOR RB ENTRY 10
  • 810514 001057 C20H001 RB SUPPORT ACTIVITY 1 MM 0.011 8.17 ANTEROOM SUPPORT FOR RB ENTRY 10
  • 810514 001057 C20H001 RB SUPPORT ACTIVITY 1 OP 0.009 1.25 ANTEROOM SUPPORT FOR RB ENTRY 10
  • 810514 001057 C20H001 RB SUPPORT ACTIVITY 1 HP 0.010 4.00 ANTEROOM SUPPORT FOR RB ENTRY 10
  • 810514 001057 C20H001 RB SUPPORT ACTIVITY 6 CN 0.025 21.66 ANTER0OM SUPPORT FOR RB ENTRY 10 810528 001156 C20H001 RB SUPPORT ACTIVITY 2 OP 0.016 2.00 AIRLOCK INTEGRITY SURVEILLANCE

$810528 001156 C20H001 RB SUPPORT ACTIVITY 1 CN 0.005 1.00 AIRLOCK INTECRITY SURVEILLANCE 810528 001147 C20H001 RB SUPPORT ACTIVITY 2 HP 0.013 10.00 ANTER0OM SUPPORT FOR RB ENTRY 11

  • 810528 001147 C20H001 RB SUPPORT ACTIVITY 6 CN 0.039 19.50 ANTEPOOM SUPPCRT FOR RB ENTRY 11
  • 810528 001147 C20H001 RB SUPPORT ACTIVITY 1 CR 0.015 5.25 ANTEROOM SUPPORT FOR RB ENTRY 11 810625 001351 C20H001 RB SUPPORT ACTIVITY 1 MM 0.005 0.58 SUPPOR T FOR RB ENTRY 12
  • 810625 001351 C20H001 RB SUPPORT ACTIVITY 6 CN 0.020 10.84 SUPPOR T FOR RB ENTRY 12
  • 810625 001351 C20H001 RB SUPPORT ACTIVITY 1 AD 0.060 1.42 SUPPORT FOR RB ENTRY 12 i

DATE 022486 PAGE 4 PNO. 3 .TMI-2 UNC: CDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS, DEPT. EXPOS. TIME

  • DATE... NUMBER.NUMBE.R............CTIVITY..............

........HOURS................................................... A ENTR. CODE. REM TASK DESCRIPTION se...

  • 810625 001351 C20H001 RB SUPPORT ACTIVITY 2 CR 0.005 3.33 SUPPORT FOR RB ENTRY 12
  • 810625 001351 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 1.25 SUPPORT FOR RB ENTRY 12 810630 001391 C20H001 RB SUPPORT ACTIVITY 2 CN 0.005 2.58 DECON FUL L BODY HARNESS 810701 001393 C20H001 RB SUPPORT ACTIVITY 2 AD 0.000 3.25 SUPPORT RB ENTRY
  • 810701 001393 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.17 SUPPORT RB ENTRY
  • 810701 C01393 C20H001 RB SUPPORT ACTIVITY 1 HP 0.010 5.08 SUPPOR T RB ENTRY
  • 810701 001393 C20H001 RB SUPPORT ACTIVITY 1 CR 0.000 1.00 SUPPORT RB EP;IRY
  • 810701 001393 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 6.75 SUPPORT RB ENTRY 810701 001396 C20H001 RB SUPPORT ACTIVITY 2 MM 0.030 2.50 INSPECT / REPAIR UNIVERSAL CONNECTIONS
  • 810101 001396 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 0.92 INSPECT /REPA!R UNIVERSAL CONNECTIONS
  • 810701 001396 C20H001 RB SUPPORT ACTIVITY 1 HP 0.010 2.50 INSPECT / REPAIR UNIVERSAL CONNECTIONS 810706 001420 C20H001 RD SUPPORT ACTIVITY 1 CN 0.010 2.00 DECON ANTER0OM AND AIRLOCK
  • 810706 001420 C20H001 NB SUPPORT ACTIVITY 4 CR 0.005 9.00 DECON ANTER0OM AND AIRLOCK 810709 001440 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 1.25 WIPE DOWN BAGGED EQUIPMENT
  • 810709 001440 C20H001 RB SUPPORT ACTIVITY 2 CN 0.005 2.50 WIPE DOWN BAGGED EQUIPMENT 810810 001653 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 4.50 EQUIPMENT FE ASIBILITY TEST 810814 001700 C20H001 RB SUPPORT ACTIVITY 2 IC 0.000 3.17 WORK ON RB CCTV HOUSING 810824 001791 C20H001 RB SUPPORT ACTIVITY 6 CN 0.008 9.00 RB ENTRY TRAINING 810827 001811 C20H001 RB SUPPORT ACTIVITY I b#1 0.005 2.58 RB ENTRY SUPPORT
  • 810827 001811 C20H001 RB SUPPORT ACTIVITY 4 OP 0.033 7.42 RB ENTRY SUPPORT
  • 810827 001811 C20P001 RB SUPPORT ACTIVITY 1 CR 0.000 4.50 RB ENTRY SUPPORT

$3*810827001811C20H001 RB SUPPORT ACTIVITY 1 OS 0.005 2.92 RB ENTRY SUPPORT 810827 001811 C20H001 RB SUPPORT ACTIVITY 5 CN 0.030 16.01 RB ENTRY SUPPORT sa **810827 001811 C20H001 RB SUPPORT ACTIVITY 2 HP 0.010 4.92 RB ENTRY SUPPORT 810903 001867 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 5.25 RB ENTRY SUPPORT

  • 810903 001867 C20H001 RB SUPPORT ACTIVITY 2 CN 0.010 4.00 RB ENTRY SUPPORT
  • 810903 001867 C20H001 RB SUPPORT ACTIVITY 1 SE 0.000 0.33 RB ENTRY SUPPORT

$810903 001867 C20H001 RB SUPPORT ACTIVITY 1 UM 0.005 2.58 RB ENTRY SUPPORT 810924 002034 C20H001 RB SUPPORT ACTIVITY 9 CN 0.025 14.58 RB ENTRY SUPPORT

  • 810924 002034 C20H001 RB SUPPORT ACTIVITY 4 OP 0.005 3.17 RB ENTRY SUPPORT
  • 810924 002034 C20H001 RB SUPPORT ACTIVITY 1 MM 0.000 0.83 RB ENTRY SUPPORT

$810924 002034 C20H001 RB SUPPORT ACTIVITY 2 EL 0.000 1.67 RB ENTRY SUPPORT

  • 810924 002034 C20H001 RB SUPPORT ACTIVITY 2 UM 0.002 6.92 RB ENTRY SUPPORT
  • 810924 002034 C20H001 RB SUPPORT ACTIVITY 1 HP 0.010 3.50 RB ENTRY SUPPORT
  • 810924 002034 C20H001 RB SUPPORT ACTIVITY 1 CR 0.000 0.83 RB ENTRY SUPPORT 811027 002278 C20H001 RB SUPPORT ACTIVITY 6 CN 0.035 15.85 RB ENTRY SUPPORT /ANTERDOM PREP
  • 811027 002278 C20H001 RD SUPPORT ACTIVITY 2 UM 0.010 10.00 RB ENTRY SUPPORT / ANTEROOM PREP
  • 811027 002278 C20H001 RB SUPPORT ACTIVITY 5 CR 0.040 12.17 RB ENTRY SUPPOR T/ ANTEROOM PRE P
  • 811027 002278 C20H001 RB SUPPOR T ACTIVITY 1 HP 0.010 3.50 RB ENTRY SUPPORT / ANTEROOM PREP 811029 002304 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.33 LEAK CHECK AIRLOCK DOORS
  • 811029 002304 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 1.08 LEAK CHECK AIRLOCK DOORS 811029 002292 C20H001 RB SUPPORT ACTIVITY 7 CN 0.045 20.37 RB ENTRY SUPPOR T/ ANTE R0OM PRE P
  • 811029 002252 C20H001 RB SUPPORT ACTIVITY 3 UM 0.008 7.83 RB ENTRY SUPPOR T/ ANTE ROOM PRE P
  • 811029 002292 C20H001 RB SUPPORT ACTIVITY 7 CR 0.025 15.52 RB E NTR Y SUPPOR T/ ANTE ROOM PRE P
  • 811029 002292 C20H001 RD SUPPORT ACTIVITY 1 HP 0.008 3.83 RB ENTRY SUPPOR T /AN TE R OOM PREP 811102 002327 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.33 INSTL WOOD FLOOR IN AIRLOCK / MODIFY RAMP
  • 811102 002327 C20H001 RB SUPPORT ACTIVITY 3 CN 0.010 2.67 INSTL WOOD FLOOR IN AIRLOCK / MODIFY RAMP
  • 811102 002327 C20H001 RB SUPPORT ACTIVITY

! HP 0.008 2.00 INSTL WOOD F100R IN AIRLOCK / MODIFY RAMP 811117 002443 C20H001 RB SUPPORT ACTIVITY 1 OP O.000 0.58 RB ENTRY SUPPORT

  • 811117 002443 C20H001 RB SUPPORT ACTIVITY 1 FM 0.005 3.75 RB ENTRY SUPPORT

DATE 022486 PAGE PNO. 4 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • ....E... NU.MBE R.. NUMBE R.....................ITY.................

.E.N T R..... C OD.... R E.M..... H OU. R S............. .....S.K D.E.SCR I PT I ON

  • DAT ACTIV TA

......=..........................

  • 811117 002443 C20H001 RB SUPPORT ACTIVITY 4 CR 0.010 16.92 RB ENTRY SUPPORT
  • 811117 002443 C20H001 RB SUPPORT ACTIVITY 12 CN 0.020 45.72 RB ENTRY SUPPORT
  • 811117 002443 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 3.95 RB ENTRY SUPPORT
  • 811117 002443 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 9.33 RB ENTRY SUPPORT 811120 002475 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.83 RB ENTRY SUPPORT
  • 811120 002475 C20H001 RB SUPPORT ACTIVITY 1 MM 0.005 4.30 RB ENTRY SUPPORT
  • 811120 002475 C20H001 RB SUPPORT ACTIVITY 11 CN 0.047 33.72 RB ENTRY SUPPORT
  • 811120 002475 C20H001 RB SUPPORT ACTIVITY

! CR 0.000 4.42 RB ENTRY SUPPORT

  • 811120 002475 C20H001 RB SUPPORT ACTIVITY 5 HP 0.013 29.83 RB ENTRY SUPPORT
  • 811120 002475 C20H001 RB SUPPORT ACTIVITY 1 AD 0.000 0.17 RB ENTRY SUPPOR T 811203 002548 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.17 RB ENTRY SUPPORT
  • 811203 002548 C20H001 RB SUPPORT ACTIVITY 17 CN 0.075 58.90 RB ENTRY SUPPORT
  • 811203 002548 C20H001 RB SUPPORT ACTIVITY 3 HP 0.020 16.58 RB ENTRY SUPPORT 811215 002629 C20H001 RB SUPPORT ACTIVITY 20 CN 0.075 92.27 RB ENTRY SUPPORT
  • 811215 002629 C20H001 RB SUPPORT ACTIVITY 2 CR 0.005 2.00 RB ENTRY SUPPORT
  • 811215 002629 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.75 RB ENTRY SUPPORT
  • 811215 002629 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 1.75 RB ENTRY SUPPORT
  • 811215 002629 C20H001 RB SUPPORT ACTIVITY 1 IC O.000 0.25 RB ENTRY SUPPORT

$811215 002629 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 9.33 RB ENTRY SUPPORT e 811217 002649 C20H001 RB SUPPORT ACTIVITY 18 CN 0.005 60.10 RB ENTRY SUPPORT 00 *811217 002649 C20H001 RB SUPPORT ACTIVITY 1 OP 0.010 1.67 RB ENTRY SUPPORT 00 *811217 002649 C20H001 RB SUPPORT ACTIVITY 3 HP 0.010 13.55 RB ENTRY SUPPORT 8 820105 002760 C20H001 RB SUPPORT ACTIVITY 21 CN 0.045 96.12 RB ENTRY SUPPORT $820105 002760 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 2.92 RB ENTRY SUPPORT

  • 820105 002760 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 8.08 RB ENTRY SUPPORT 820107 002783 C20H001 RB SUPPORT ACTIVITY 17 CN 0.014 61.32 RB ENTRY SUPPORT
  • 820107 002783 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.50 RB ENTRY SUPPORT
  • 820107 002783 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 4.80 RB ENTRY SUPPORT

$820107 002783 C20H001 RB SUPPORT ACTIVITY ! HP 0.000 5.27 RB ENTRY SUPPORT 820114 002827 C20H001 RB SUPPORT ACTIVITY 16 CN 0.040 74.92 RB ENTRY SUPPORT

  • 820114 002827 C20H001 RB SUPPORT ACTIVITY I OP 0.005 0.92 RB ENTRY SUPPORT
  • 820114 002827 C20H001 RP SUPPORT ACTIVITY

! UM 0.000 4.33 RB ENTRY SUPPORT

  • 820114 002827 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 12.25 RB ENTRY SUPPORT 820120 002864 C20H001 RB SUPPORT ACTIVITY 6 CN 0.018 10.33 DECON PERSONNEL AIRLOCK / REMOVE TRASH 820126 002894 C20H001 RB SUPPORT ACTIVITY 15 CN 0.061 68.67 RB ENTRY SUPPORT
  • 820126 002894 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 6.88 RB ENTRY SUPPORT 820127 002905 C20H001 RB SUPPORT ACTIVITY 2 CN 0.015 3.00 RB ENTRY SUPPORT 820128 002913 C20H001 RB SUPPORT ACTIVITY 8 CN 0.010 20.58 RB ENTRY SUPPORT
  • 820125 002913 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.17 RB ENTRY SUPPORT

$820128 002913 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 3.00 RB ENTRY SUPPORT 820129 002924 C20H001 RB SUPPORT ACTIVITY 5 CN 0.010 14.00 PREPARE SURFACE DEPOSITION SAMPLES 820204 002973 C20H001 RB SUPPORT ACTIVITY 13 CN 0.024 40.70 DECON ANTEROOM

  • 820204 002973 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 5.78 DECON ANTEROOM 820204 002959 C20H001 RB SUPPORT ACTIVITY 17 CN 0.019 84.02 RB ENTRY SUPPORT
  • 820204 002959 C20H001 RB SUPPORT ACTIVITY 2 OP 0.007 2.50 RB ENTRY SUPPORT
  • 820204 002959 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.48 RB ENTRY SUPPORT
  • 820204 002959 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 16.70 RB ENTRY SUPPORT 820208 002989 C20H001 RB SUPPORT ACTIVITY 19 CN 0.066 89.08 DECON ANTER0OM 820208 003010 C20H001 RB SUPPORT ACTIVITY 2 CN 0.005 12.33 INSTALL CONTAMINATION CONTROL CORRIDOR 820209 003008 C20H001 RB SUPPORT ACTIVITY 8 CN 0.005 20.17 DECON ANTEROOM

DATE 022486 PAGE 6 PNO. 5 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. .. E. N T R.......,................................IPTION PERS. DEPT. EXPOS. TIME

  • DATE
  • ....... NUMBER. NUMBER........................Y........

ACTIVIT . CODE. REM . HOURS TASK DESCR

  • 820209 003008 C20H001 RB SUPPORT ACTIVITY 2 IC 0.000.

1.33. DECON ANTERDOM 820211 003019 C20H001 RB SUPPORT ACTIVITY 10 CN 0.010 34.47 INSTALL CONTAMINATION CONTROL CORRIDOR 820215 003031 C20H001 RB SUPPORT ACTIVITY 9 CN 0.003 19.67 INSTALL CCNTAMINATION CONTROL CORRIDOR 820216 003041 C20H001 RB SUPPORT ACTIVITY 17 CN 0.068 65.74 RB ENTRY SUPPORT $820216 003041 C20H001 RB SUPPORT ACTIVITY 2 HP 0.010 15.67 R8 ENTRY SUPPORT

  • 820216 003041 C20H001 R8 SUPPORT ACTIVITY 1 UM 0.000 5.17 RB ENTRY SUPPCRT 820217 003059 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.83 DECON ANTERDOM AND AIRLOCK
  • 820217 003059 C20H001 RB SUPPORT ACTIVITY 8 CN 0.007 12.99 DECON ANIER00M AND AIRLOCK 820217 003069 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.95 RB ENTRY SUPPORT
  • 820217 003069 C20H001 RB SUPPORT ACTIVITY 19 CN 0.015 45.25 R8 ENTRY SUPPORT
  • 820217 003069 C20H001 RB SUPPORT ACTIVITY 4 HP 0.000 13.50 RB ENTRY SUPPORT 820222 003101 C20H001 RB SUPPORT ACTIVITY 4 CN 0.005 4.75 DECON ANTEROOM AND AIRLOCK

$820222 C03101 C20H001 R8 SUPPORT ACTIVITY 1 HP 0.000 1.00 DECON ANTER0OM AND AIRLOCK 820224 003115 C20H001 RB SUPPORT ACTIVITY 31 CN 0.035 116.37 RB ENTRY SUPPORT

  • 820224 003115 C20H001 RB SUPPORT ACTIVITY 5 HP 0.000 26.33 RB ENTRY SUPPORT 820226 003137 C20H001 RB SUPPORT ACTIVITY 3 HP 0.000 12.92 R8 ENTRY SUPPCRT
  • 820226 003137 C20H001 RB SUPPORT ACTIVITY 1 Op 0.000 1.50 RB ENTRY SUPPORT
  • 820226 003137 C20H001 RB SUPPORT ACTIVITY 26 CN 0.028 103.36 RB ENTRY SUPPORT 820301 003160 C20H001 RB SUPPORT ACTIVITY 4 CN 0.023 12.42 DECON ANTEROOM AND AIRLOCK
  • 820301 0033r0 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 3.17 DECON ANTEROOM AND AIRLOCK s

820302 003172 C20H001 RB SUPPORT ACTIVITY 23 CN 0.080 82.89 R8 ENTRY SUPPORT 00 *820302 003172 C20H001 R8 SUPPORT ACTIVITY 6 HP 0.005 39.83 RB ENTRY SUPPORT M3 820303 003191 C20H001 R8 SUPPORT ACTIVITY 8 HP 0.005 46.08 RB ENTRY SUPPORT 8 2820303 003191 C20H001 RB SUPPORT ACTIVITY 3 OP 0.007 3.50 RB ENTRY SUPPORT

  • 820303 003191 C20H001 RB SUPPORT ACTIVITY 30 CN 0.032 127.70 R8 ENTRY SUPPORT 820308 003211 C20H001 R8 SUPPORT ACTIVITY 16 CN 0.045 70.21 RB ENTRY SUPPORT
  • 820308 003211 C20H001 RB SUPPORT ACTIVITY 2 CH 0.000 12.92 RB ENTRY SUPPORT
  • 820308 003211 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 11.50 RB E NTRY SUPPORT 820308 003236 C20H001 RB SUPPORT ACTIVITY 15 CN 0.01E 38.08 DECON ANTEROOM AND AIRLOCK 820310 003247 C20H001 RB SUPPORT ACTIVITY 2 OP 0.002 3.00 RB ENTRY SUPPORT
  • 820310 003247 C20H001 RB SUPPORT ACTIVITY 51 CN 0.079 234.76 RB ENTRY SUPPORT
  • 820310 003247 C20H001 RB SUPPORT ACTIVITY 6 CH 0.000 39.34 RB ENTRY SUPPORT
  • 820310 003247 C20H001 RB SUPPORT ACTIVITY 4 HP 0.000 32.6/

RB ENTRY SUPPORT 820315 w03281 C20H001 R8 SUPPORT ACTIVITY 5 CN 0.000 19.62 OPERATE HVOROLASER PUMP 820315 003276 C20H001 RB SUPPORT ACTIVITY 14 HP 0.043 88.25 RB ENTRY AND DECON EXP. SUPPORT

  • 870315 003276 C20H001 RB SUPPORT ACTIVITY 56 CN 0.133 217.70 RB ENTRY AND DECON EXP. SUPPORT
  • 820315 003276 C20H001 RB SUPPORT ACTIVITY 3 CH 0.005 17.42 RB ENTRY AND DECON EXP. SUPPORT
  • 820315 003276 C20H001 RB SUPPORT ACTIVITY 2 OP 0.002 0.00 RB ENTRY AND DECON EXP. SUPPORT
  • 820315 003276 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 2.00 RB ENTRY AND DECON EXP. SUPPORT 820322 003356 C20H001 RB SUPPORT ACTIVITY 58 CN 0.107 206.71 R8 ENTRY AND DECON EXP. SUPPORT
  • 820322 003356 C20H001 R8 SUPPORT ACTIVITY 15 HP 0.004 57.92 RB ENTRY AND DECON EXP. SUPPORT
  • 820322 003356 C'0F001 R8 SUPPORT ACTIVITY 2 UM 0.000 1.67 RB ENTRY AND DECON EXP. SUPPORT
  • 820322 003356 C20H001 RB SUPPORT ACTIVITY 5 OP 0.005 7.50 RB ENTRY AND DECON EXP. SUPPORT
  • 820322 003356 C20H001 RB SUPPORT ACTIVITY 1 SE 0.002 1.67 RB ENiRY AND DECON EXP. SUPPORT
  • 820322 003356 C20H001 RB SUPPORT ACTIVITY

! MM 0.000 0.83 RB ENTRY AND DECCN EXP. SUPPORT 820326 003401 C20H001 RB SUPPORT ACTIVITY I CN 0.005 1.50 CLOSE WDG - V100A & WDG V17A

  • 820326 003401 C20H001 RB SUPPORT ACTIVITY 1 OP 0.010 1.75 CLOSE WDG - V100A & WDG V17A 820330 003422 C20H001 R8 SUPPORT ACTIVITY 2 HP J,J00 4.00 DECON ANTERCOM. AIRLOCK & EQUIPMENT
  • 820330 003422 C20H001 RB SUPPORT ACTIVITY 19 CN 0.066 43.92 DECON ANTEROOM. AIRLCCK & EQUIPMENT 820331 003436 C20H001 RB SUPPORT ACTIVITY 1 HP 0.180 2.67 HP SURVEYS & COVERAGE

m _. DATE 022486 PAGE 7 PNO. 6 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME 820331 003437 C20H001 RB SUPPORT ACTIVITr 13 CN 0.140 38.83. .......... E. S.C R I P T I ON , REM TASK D ..ENTR...s.. CODE.......,.......HOURh.............. ...................IVITY ACT

  • DATE. NUMBER. NUMBER RB ENTRY SUPPORT
  • 820331 003437 C20H001 RB SUPPORT ACTIVITY 1 CH 0.005 2.92 RB ENTRY SUPPORT 3820331 003437 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.25 R8 ENTRY SUPPORT
  • 820331 003437 C20H001 RS SUPPORT ACTIVITY 1 UM 0.000 6.58 Rb ENTRY SUPPORT
  • 820331 003J37 C20H001 RD SUPPORT ACTIVITY I HP 0.000 6.50 RB ENTRY SUPPORT 820405 003480 C20H001 R8 SUPPORT ACTIVITY 30 CN 0.120 97.91 DECON ANTEROOM. AIRLOCK, EQUIP. & TOOLS
  • 820405 003480 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.67 DECON ANTEROOM. AIRLOCK, EQUIP. & TOOLS
  • 820405 003480 C20H001 RB SUPPORT ACTIVITY 3 HP 0.000 8.50 DECON ANTEROOM, AIRLOCK, EQUIP. & TOOLS 820409 003521 C20H001 R8 SUPPORT ACTIVITY 22 CN 0.040 74,10 CONSTRUCT CONTAMINATION CNTRL CORRIDOR 820414 003584 C20H001 RB SUPPORT ACTIVITY 27 CN 0.027 92.50 CONST CONTAMINATION CNTRL CORR-ANTEROOM 820414 003585 C20H001 RB SUPPORT ACTIVITY 16 CN 0.025 56.45 DECON TOOLS & EQUIP IN ANTEROOM 820414 003564 C20M001 RB SUPPORT ACTIVITY 14 CN 0.038 28.62 RB ENTRY SUPPORT
  • 820414 003564 C20H001 RB SUPPORT ACTIVITY 1 FN 0.005 0.25 RB ENTRY SUPPORT
  • 820414 003564 C20H001 R8 SUPPORT ACTIVITY 3 OP 0.006 5.92 RB ENTRY SUPPORT
  • 820414 003564 C20H001 RB SUPPORT ACTIVITY 1 CH 0.005 2.50 RB ENTRY SUPPORT
  • 820414 003564 C20H001 RB SUPPORT ACTIVITY 4 HP 0.000 12.33 RB ENTRY SUPPORT 820414 003577 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 3.00 R8 ENTRY AND EXIT SUPPORT

$820414 003577 C20H001 R8 SUPPORT ACTIVITY I OP 0.005 1.50 RB ENTRY AND EXIT SUPPORT

  • 820414 003577 C20H001 RB SUPPORT ACTIVITY 3 CN 0.020 9.50 RB ENTRY AND E XIT SUPPORT 820422 003644 C20H001 RS SUPPORT ACTIVITY 13 CN 0.040 51.68 RB ENTRY SUPPORT RB SUPPORT ACTIVITY 2 CH 0.000 12.33 RB ENTRY SUPPORT E **820422 003644 C20H001 RB SUPPORT ACTIVITY 3 HP 0.000 14.58 RB ENTRY SUPPORT o *820422 003644 C20H001 820422 003644 C20H001 RB SUPPORT ACTIVITY

! FN 0.015 1.58 R8 ENTRY SUPPORT 820423 003655 C20H001 RB SUPPORT ACTIVITY 8 CN 0.015 16.08 DECON ANTEROOM & AIRLOCK 820426 003673 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.42 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP

  • 820426 003673 C20H001 RB SUPPORT ACTIVITY 13 CN 0.018 42.71 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP 820426 003674 C20H001 R8 SUPPORT ACTIVITY 3 CN 0.005 7.17 MODIFY CONTAMINATION CONTROL CORRIDOR 820428 003697 C20H001 RB SUPPORT ACTIVITY 11 CN 0.016 50 00 RB ENTRY SUPPORT
  • 820428 003697 C20H001 R8 SUPPORT ACTIVITY I RC 0.003 5.00 RB ENTRY SUPPORT
  • 820428 003697 C20H001 RB SUPPORT ACTIVITY 3 HP 0.002 18.75 RB ENTRY SUPPORT
  • 820428 003697 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 2.33 RB ENTRY SUPPORT 820503 003751 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 8.00 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP 820503 003753 C20H001 RC SUPPORT ACTIVITY 2 CN 0.008 7.67 MODIF Y CONT AMINATION CONTROL CORRIDOR 820505 003764 C20H001 R8 SUPPORT ACTIVITY 7 CN 0.035 29.67 R8 ENTRY SUPPORT
  • 820505 003764 C20H001 R8 SUPPORT ACTIVITY 5 HP 0.000 24.75 RB ENTRY SUPPORT
  • 820505 003764 C20H001 R8 SUPPORT ACTIVITY 3 OP 0.015 6.50 RB ENTRY SUPPORT 820510 003806 C20H001 RB SUPPORT ACTIVITY 9 CN 0.011 34.00 RB ENTRY SUPPORT
  • 820510 003806 C20H001 RB SUPPORT ACTIVITY 6 HP 0.145 31.42 RB ENTRY SUPPORT
  • 820510 003806 C20H001 RB SUPPORT ACTIVITY I OP 0.000 2.00 RB ENTRY SUPPORT 820511 003824 C20H001 R8 SUPPORT ACTIVITY 7 CN O 009 24.36 DECON ANTEROOM. TOOLS & EQUIP 820511 003824 C20H001 R8 SUPPORT ACTIVITY 1 HP 0.000 0.12 DECON ANTEROOM. TOOLS & EQUIP 820513 003839 C20H001 RB SUPPORT ACTIVITY 18 CN 0.021 57.90 RB ENTRY SUPPORT
  • 820513 003839 C20H001 RB SUPPORT ACTIVITY 4 HP 0.005 25.83 RB ENTRY SUPPORT
  • 820513 003839 C20H001 RB SUPPORT ACTIVITY 2 OP 0.005 3.17 RB ENTRY SUPPORT 820518 003901 C20H001 RB SUPPORT ACTIVITY 5 CN 0.015 14.25 DECON ANTEROOM. T00t S & EOUIP

$820518 003901 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.33 DECON ANTER0OM, TOOLS & EQUIP 820526 003954 C20H001 RB SUPPORT ACTIVITY 16 CN 0.013 56.95 RB ENTRY SUPPORT

  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 4.08 RB ENTRY SUPPORT
  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 1 ES 0.000 0.50 RB ENTRY SUPPORT
  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 1 RC 0.005 9.67 RB ENTRY SUPPORT

DATE 022486 PAGE 8 PNO. 7 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. ATE

............. T. I VI. T Y...........,...............C.ODE... REM........PO.URS .....NUMBE.R.NUMBE.R .....................S.K DESCRIPTI.ON AC ENTR TA

  • 820526 003954 C20H001 RB SUPPORT ACTIVITY 3 HP 0.003 30.25 RB ENTRY SUPPORT 820526 003959 C20H001 RB SUPPORT ACTIVITY 10 CN 0.072 32.25 DECON ANTEROOM. AIRLOCK. TOOLS & EQUIP 820601 003992 C20H001 RB SUPPORT ACTIVITY 3 CN 0.010 9.67 MODIFY CONTAMINATION CONTROL CORRIDOR 820602 004007 C20H001 RB SUPPORT ACTIVITY 9 CN 0.010 24.75 DECON ANTEROOM. AIRLOCK, TOOLS & EQUIP
  • 820602 004007 C20H001 RB SUPPORT ACTIVITY 1 RC 0.005 3.58 DECON ANTEROOM. AIRLOCK, TOOLS & EQUIP 820603 004000 C20H001 RB SUPPOR T ACTIVITY 13 CN 0.032 50.57 RB ENTRY SUPPORT
  • 820603 004000 C20H001 RB SUPPORT ACTIVITY 2 RC 0.000 11.25 RB ENTRY SUPPORT
  • 820603 004000 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 8 13 RB ENTRY SUPPORT 820604 004009 C20H001-RB SUPPORT ACTIVITY 3 CN 0.015 7.33 REPAIR OR REPLACE LIGHTS & LIMIT SWITCH
  • 820604 004009 C20H001 RB SUPPORT ACTIVITY 4 EL 0.073' 14.25 REPA!R OR REPLACE LIGHTS & LIMIT SWITCH

$820604 004009 C20H001 RB SUPPORT ACTIVITY 2 MD 0.032 8.25 REPAIR OR REPLACE LIGHTS & LIMIT SWITCH 820610 004037 C20H001 R6 SUPPORT ACTIVITY 11 CN 0.022 43.40 RB ENTRY SUPPORT

  • 820610 004037 C20H001 RB SUPPORT ACTIVITY 5 HP 0.000 26.67 RB ENTRY SUPPORT
  • 820610 004037 C20H001 RB SUPPORT ACTIVITY 1 RC 0.000 0.08 RB ENTRY SUPPORT 820617 004087 C20H001 RB SUPPORT ACTIVITY 11 CN 0.023 31.63 RB ENTRY SUPPORT
  • 820617 004087 C20H001 RB SUPPORT ACTIVITY 7 HP 0.010 34.07 RB ENTRY SUPPORT
  • 820617 004087 C20H001 RB SUPPORT ACTIVITY

! OP 0.005 2.25 RB ENTRY SUPPORT 820622 004126 C20H001 RB SUPPORT ACTIVITY 25 CN 0.049. 84.18 RB ENTRY SUPPORT

  • 820622 004126 C20H001 RB SUPPORT ACTIVITY 11 HP 0.069 71.63 RB ENTRY SUPPORT 820624 004143 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.75 LEAK CHECK DOORS 8
  • 820624 004143 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.75 LEAK CHECK DOORS 43 820624 004149 C20H001 RB SUPPORT ACTIVITY 8 CN 0.015 15.25 DECON ANTEROOM AIRLOCK. TOOLS & EQUIP 820630 004187 C20H001 RB SUPPORT ACTIVITY 12 CN 0.047 38.25 RB ENTRY SUPPOET
  • 820630 004187 C20H001 RB SUPPORT ACTIVITY 7 HP 0.009 48.65 RB ENTRY SUPPORT
  • 820630 004187 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.83 RB ENTRY SUPPORT

$820630 004187 C20H001 RB SUPPORT ACTIVITY 1 MM 0.000 0.75 RB ENTRY SUPPORT 820630 004189 C20H001 RB SUPPORT ACTIVITY 2 CN 0.164 4.83 TOOL INVENTORY & STORAGE 820701 004196 C20H031 RB SUPPOPT ACTIVITY 2 OP 0.018 1,67 OPERATE FSV-639 DURING RB ENTRY

  • 820701 004196 C20H001 RB SUPFuRT ACTIVITY 2 HP 0.025 1.50 OPERATE FSV-639 DURING RB ENTRY 820702 004202 C20H001 RB SUPPORT ACTIVITY 14 CN 0.012 23.53 GENERAL DECON & CLEANUP
  • 820702 004202 C20H001 RB SUPPORT ACTIVITY 2 HP 0.010 7.17 GENERAL DECON & CLEANUP 820707 004235 C20H001' RB SUPPORT ACTIVITY 11 CN 0.010 27.66 RB ENTRY SUPPORT
  • 820707 004235 C20H001 RB SUPPORT ACTIVITY -

1 OP 0.005 2.50 RB ENTRY SUPPORT

  • 820707 004235 C20H001 RB SUPPORT ACTIVITY 9 HP 0.000 53.72 RB ENTRY SUPPORT
  • 820707 004235 C20H001 RB SUPPORT ACTIVITY 1 IC 0.005 1.17 RB ENTRY SUPPORT 820712 004267 C20H001 RB SUPPORT ACTIVITY 3 HP 0.496 4.92 HP SURVEY & COVERAGE 820712 004263 C20H001 RB SUPPORT ACTIVITY 43 CN 0.157 135.63 RB ENTRY SUPPORT
  • 820712 004263 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 1.75 RB ENTRY SUPPGAT
  • 820712 004263 C20H001 RB SUPPORT ACTIVITY 29 HP 0.010 162.17 RB ENTRY SUPPORT
  • 820712 004263 C20H001 RB SUPPORT ACTIVITY-2 AM 0.000 0.38 RB ENTRY SUPPORT 820715 004291 C20H001 RB SUPPORT ACTIVITY 1 HP 0.075 0.17 GENERIC HP SURVEY 820719 004317 C20H001 RB SUPPORT ACTIVITY 35 CN 0.173 112.90 RB ENTRY SUPPORT
  • 820719 004317 C20H001 RB SUPPORT ACTIVITY 18 HP 0.008 139.50 RB ENTRY SUPPORT
  • 820719 004317 C20H001 RB SUPPORT ACTIVITY 1 MM 0.010 1.17 RB ENTRY SUPPORT
  • 820719 004317 C20H001 RB SUPPORT ACTIVITY 1 CR 0.000 0.50 RB ENTRY SUPPORT
  • 820719 004317 C20H001 RB SUPPORT ACTIVITY 1 OP 0.003 0.67 RB ENTRY SUPPORT
  • 820719 004317 C20H001 RB SUPPORT ACTIVITY I AM 0.000 0.33 RB ENTRY SUPPORT 820721 004336 C20H001 RB SUPPORT ACTIVITY 1 HP 0.017 1.00 GENERIC RADIOLOGICAL SURVEY 820726 004358 C20H001 RB SUPPGRT ACTIVITY

.4 CN 0.010 6.83 RELOCATE CAMERA / REMOVE PLEXIGLASS WALL 820727 004380 C20H001 RB SUPPORT ACTIVITY I CN 0.000 8.33 OPERATE NLB PUMP

~ _ ~. - - - ._.w ~ _. - .~. .. _.,~ f 3 i 4 DATE 022486 PAGE 9 PNO. 8 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D i PERS. DEPT. EXPOS. TIME .* RWP ,RWP .EXP TRCK. ......... T. I V I T. Y. e..................... O. D. E.... R E.M.... H O U. R S................. S. K..D. E. S.C. R AC... . ENTR C TA 3.D. A T.E... NUMB.E.R. NUMB.E. R.... 820727 004374 C20H001 RB SUPPORT ACTIVITY 4 CN 0.045 8.57 RB ENTRY SUPPORT 820727 004376 C20H001 RB SUPPORT ACTIVITY 1 HP 0.105 1.00 SLUDGE SAMPLE SURVEY / COVERAGE 820728 004379 C20H001 RB SUPPORT ACTIVITY -15 CN 0.020 33.48 RB ENTRY SUPPORT 8820728 004379 C20H001 RB SUPPORT ACTIVITY 9 HP 0.020 48.33 RB ENTRY SUPPORT i

  • 820728 004379 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.67 RB ENTRY SUPPORT 820803 004418 C20H001 RB SUPPORT ACTIVITY 2 CN 0.005 3.75 OPERATE NLB PUMP 820803 004427 C20H001 RB SUPPORT ACTIVITY 3 CN 0.397 5.25 STAGE MATERIAL / REMOVE TRASH l

820803 00442' C20H001 RB SUPPORT ACTIVITY 1 HP 0.146 2.17 HP SURVEY-GEN. AREA & SERV. STRUCTURE 820804 004435 C20H001 RB SUPPORT ACTIVITY 45 CN 0.060 147.13 RB ENTRY SUPPORT

  • 820804 004435 C20H001 RB SUPPORT ACTIVITY 23 HP 0.077 136.77 RB ENTRY SUPPORT
  • 820804 004435 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 0.83 RB ENTRY SUPPORT 820804 004436 C20H001 RB SUPPORT ACTIVITY 15 CN 0.184 31.08 RB ENTRY SUPPORT 820811 004467 C20H001 RB SUPPORT ACTIVITY 7 CN 0.118.14.72 RB ENTRY SUPPORT i

820811 004468 C20H001 RB SUPPORT ACTIVITY 21 CN 0.067 55.97 RB ENTRY SUPPORT

  • 820811 004468 C20H004 RB SUPPORT ACTIVITY 18 HP 0.040 109.65 RB ENTRY SUPPORT
  • 820811 004468 C20H001 RB SUPPORT ACTIVITY 2 OP 0.007 4.50 RB ENTRY SUPPORT i
  • 820811 004468 C20H001 RB SUPPORT ACTIVITY 2 AM 0.000 0.55 RB ENTRY SUPPORT
  • 820811 004468 C20H001 RB SUPPORT ACTIVITY 1 CR 0.005 1.25 RB ENTRY SUPPORT i

I 820812 004487 C20H001 RB SUPPORT ACTIVITY 3 CN 0.005 1.27 TRASH REMOVAL 7 820812 004488 C20H001 RB SUPPORT. ACTIVITY 1 HP 0.026 0.50 HP SURVEY & ENTRY COVERAGE s 820813 004496 C20H001 RB SUPPORT ACTIVITY 4 CN 0.423 5.75 TRASH REMOVAL up $820813 004496 C20H001 RB SUPPORT ACTIVITY 1 CR 0.157 1.42 TRASH REMOVAL DJ 820813 004498 C20H001 RB SUPPORT ACTIVITY 1 HP 0.010 0.50 HP SURVEY 8 820816 004501 C20H001 RB SUPPORT ACTIVITY 35 CN 0.069 107.64 RB ENTRY SUPPORT

  • 820816 004501 C20H001 RB SUPPORT ACTIVITY 33 HP 0.057 189.50 RB ENTRY SUPPORT a..
  • 820816 004501 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.08 RB ENTRY SUPPORT o
  • 820816 004501 C20H001 RB SUPPORT ACTIVITY 1 CH 0.000 0.17 RB ENTRY SUPPORT l
  • 820816 004501 C20H001 RB SUPPORT ACTIVITY 1 AM 0,000 0.33 RB ENTRY SUPPORT

[ '*820816 004501 C20H001 RB SUPPORT ACTIVITY 2 CR 0.005 5.75 RB ENTRY SUPPORT 820816 004502 C20H001 RB SUPPORT ACTIVITY 13 CN 0.242 29.75 RB ENTRY AIRLOCK SUPPORT l 820818 004513 C20H001 RB SUPPORT ACTIVITY 12 CN 0.000 39.49 OPERATE NLB PUMP $820818 004513 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.33 OPERATE NLB PUMP l . 820818 004515 C20H001 RB SUPPORT ACTIVITY 1 OP 0.010 0.50 OPERATE FSV-639 FOR RB ENTRY 'i f

  • 820818 004515 C20H001 RB SUPPORT ACTIVITY 1 HP 0.005 0.50 OPERATE FSV-639 FOR RB ENTRY 820819 004541 C20H001 RB SUPPORT ACTIVITY 1 HP 0.107 1.83 AIR SAMPLE AND TRASH REMOVAL

$820819 004541 C20H001 RB SUPPORT ACTIVITY 5 CN 0.384 3.84 AIR SAMPLE AND TRASH REMOVAL 820820 004548 C20H001 RB SUPPORT ACTIVITY 2 HP 0.112 1.43 HP SURVEY 820823 004555 C20H001 RB SUPPORT ACTIVITY 39 CN 0.047 152.68 RB ENTRY SUPPORT +

  • 820823 004555 C20H001 RB SUPPORT ACTIVITY 28 HP 0.022 161.57 RB ENTRY SUPPORT
  • 820823 004555 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2,50 RB ENTRY SUPPORT
  • 820823 004555 C20H001 RB SUPPORT ACTIVITY 2 CR 0.000 6.17 RB ENTRY SUPPORT a

820823'004556 C20H001 RB SUPPORT ACTIVITY 11 CN 0.236 22.87 RB ENTRY SUPPORT IN AIRLOCK i

  • 820823 004556 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.00 RB ENTRY SUPPORT IN AIRLOCK i

820824 004565 C20H001 RB SUPPORT ACTIVITY 8 CN 0.000 9.12 REPAIR ORANGE GOOSE HYDROLASER PUMP

  • 820824 004565 C20H001.RB SUPPORT ACTIVITY 1 HP 0.000 1.33 REPAIR ORANGE GOOSE HYDROLASER PUMP i

820826 004587 C20H001 RB SUPPORT ACTIVITY 1 HP 0.080 1.00 HP SURVEY 820826 004594 C20H001 RB SUPPORT ACTIVITY 14 CN 0.017 51.83 OPERATE NLB PUMP & GENERAL DECON 820827 004613 C20H001 RB SUPPORT ACTIVITY 11 CN 0.015 24.20 RUN CONDUIT / INSTALL HANGERS-MODEL ROOM 820830 004601 C20H001 RB SUPPORT ACTIVITY 2 HP 0.043 1.67 HP SURVEY 820830 004605 C20H001 RB SUPPORT ACTIVITY 9 CN, 0.182 20.00 RB ENTRT SUPPORT IN AIRLOCK I i 6 l

DATE 022486 PAGE 10 PNO. 9 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCX. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER. NUMBER ACTIVITY ENIR

. HOURS TASK DESCRIPTION 3............................................................ CODE........ REM 820830 00460C C20H001 RB SUPPORT ACTIVITY 37 CN 0.178 113.08 RB ENTRY SUPPORT

  • 820830 004606 C20H001 RB SUPPORT ACTIVITY 24 HP 0.012 129.15 RB ENTRY SUPPORT
  • 820830 004c06 C20H001 RB SUPPORT ACTIVITY 5 OP 0.010 6.92 RB ENTRY SUPPORT
  • 820830 004606 C20H001 RB SUPPORT ACTIVITY 1 VI 0.000 1.08 RB ENTRY SUPPORT
  • 820830 004606 C20H001 RB SUPPORT ACTIVITY 3 CR 0.000 8.00 RB ENTRY SUPPORT 820830 004607 C20H001 RB SUPPORT ACTIVITY 11 CN 0.064 39.83 DECON EQUIPMENT HATCH

$820830 004607 C20H001 RB SUPPORT ACTIVITY 1 HP 0.005 2.50 DECON EQUIPMENT HATCH 820901 004621 C20H001 RB SUPPORT ACTIVITY 8 CN 0.403 5.50 INSTALL WORK PLATFORM AND RAMP 820902 004640 C20H001 RB SUPPORT ACTIVITY 3 CN 0.001 13.08 NLB PUMP OPERATION & MAINTENANCE 82C907 004658 C20H001 RB SUPPORT ACTIVITY 23 CN 0.012 65.45 RB ENTRY SUPPORT - ANTEROOM

  • 820907 004658 C20H001 RB SUPPORT ACTIVITY 18 HP 0.030 96.50 RB ENTRY SUPPORT - ANTER0OM
  • 820907 004658 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.58 RB ENTRY SUPPORT - ANTEROOM
  • 820907 004658 C20H001 RB SUPPORT ACTIVITY 2 CR 0.000 7.75 RB ENTRY SUPPORT - ANTER0OM 820907 004659 C20H001 RB SUPPORT ACTIVITY 6 CN 0.111 12.42 RB ENTRY SUPPORT - AIRLOCK 820907 004651 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 1.28 PULL CABLE & MAKE CONNECTIONS - MODEL RM 820909 004680 C20H001 RB SUPPORT ACTIVITY 4 CN 1.389 6.82 INSTALL RAMP & PLATFORM - EQUIP. HATCH 820910 004674 C20H001 RB SUPPORT ACTIVITY 3 CN 0.008 11,75 OPERATE NLB PUMP 820913 004691 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 5.41 RUN CONDUIT /TEPMINATE CABLES - MODEL PM

$820913 004691 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.67 RUN CONDUIT /IERMINATE CABLES - MODEL RM 820914 004699 C20H001 RB SUPPORT ACTIVITY 5 CN 0.040 25.25 DECON EQUIPMENT HATCH 820914 004704 C20H001 RB SUPPORT ACTIVITY 32 CN 0.052 99.83 RB ENTRY SUPPORT ,e *820914 004704 C20H001 RB SUPPORT ACTIVITY 25 HP 0.035 119.42 RB ENTRY SUPPORT ca *820914 004704 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.67 RB ENTRY SUPPORT e

  • 820914 004704 C20H001 RB SUPPORT ACTIVITY 3 CR 0.040 5.08 RB ENTRY SUPPORT 820914 004705 C20H001 RB SUPPORT ACTIVITY 10 CN 0.182 23.97 RB ENTRY SUPPORT - AIRLOCK 820917 004720 C20H001 RB SUPPORT ACTIVITY 6 CN 1.167 11.25 BAG TOOLS & TRASH / REMOVE FROM RB 820917 004722 C20H001 RB SUPPORT ACTIVITY 1 CN 0.197 1.00 TRASH & TOOL REMOVAL 820920 004740 C20H001 RB SUPPORT ACTIVITY 11 CN 0.005 20.42 OPERATE NLB PUMP
  • 820920 004740 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.33 OPERATE NLB PUMP 820922 004750 C20H001 RB SUPPORT ACTIVITY 48 CN 0.057 128.07 RB ENTRY SUPPORT - ANTER0OM
  • 820922 004750 C20H001 RB SUPPORT ACTIVITY 31 HP 0.048 144.43 RB ENTRY SUPPORT - ANTEROOM
  • 820922 004750 C20H001 RB SUPPORT ACTIVITY 4 OP 0.010 4.50 RB ENTRY SUPPORT - ANTER0OM

$820922 004750 C20H001 RB SUPPORT ACTIVITY 1 MM 0.000 0.83 RB ENTRY SUPPORT - ANTEROOM 820922 004751 C20H001 RB SUPPORT ACTIVITY 14 CN 0.156 28.63 RB ENTRY SUPPORT - AIRLOCK 820923 004771 C20H001 RB SUPPORT ACTIVITY 2 CN 0.181 1.24 INSTALL PLATFOPM & RAMP AT AIRLOCK NO. 1 820924 004772 C20H001 RB SUPPORT ACTIVITY 1 CR 0,130 0.78 MISC. TOOL, SAMPLE & TRASH REMOVAL 820927 004792 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 20.33 OPERATE NLB PUMP 820928 004801 C20H001 RB SUPPORT ACTIVITY 1 HP 0.125 0.78 RAD SURVEY & HP COVERAGE - RB 'D' RING 821001 004825 C20H001 RB SUPPORT ACTIVITY 1 HP 0.239 1.08 R AD SURVEY & HP COVERAGE - RB 821001 004829 C20H001 RB SUPPORT ACTIVITY 11 CN 0.095 23.96 RB ENTRY SUPPORT - AIRLOCK

  • 821001 004829 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 2.17 RB ENTRY SUPPORT - AIRLOCK
  • 821001 004829 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.25 RB ENTRY SUPPORT - AIRLOCK 821001 004830 C20H001 RB SUPPORT ACTIVITY 37 CN 0.097 94.54 RB ENTRY SUPPORT - ANTERDOM
  • 821001 004830 C20H001 RB SUPPORT ACTIVITY 23 HP 0.024 125.13 RB ENTRY SUPPORT - ANTEROOM
  • 821001 004830 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 2.88 RB ENTRY SUPPORT - ANTEROOM 821004 004838 C20H001 RB SUPPORT ACTIVITY 1 HP 0.066 0.83 RADIATION SURVEY & HP COVERAGE 821004 004841 C20H001 RB SUPPORT ACTIVITY 7 CN 0.000 21.60 OPERATE NLB PUMP / PERFORM MAINT.

821006 004859 C20H001 RB SUPPORT ACTIVITY 1 HP 0.075 0.93 R ADI ATION SURVE Y/HP COVERAGE 821007 004866 C20H001 RB SUPPORT ACTIVITY 2 RP 0.270 2.50 TRASH AND TOOL REMOVAL 821007 004867 C20H001 RB SUPPORT ACTIVITY I HP 0.101 1,58 RADIATION SURVEY & HP COVERAGE

DATE 022486 PAGE 11 PNO. 10 .TMI-2 UNC-DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • rwa

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME 821008 004869 C20H001 RB SUPPORT ACTIVITY 64 CN 0.055 189.36. ................ T..I O N TASK DESCRIP ..... HOURS.......

  • DATE. NUMBER. NUMBER,

ACTIVITY . CODE .RE.N s................................................ ENIR RB ENTRY SUPPORT - ANTEROOM

  • 821008 004869 C20H001 RB SUPPORT ACTIVITY 43 HP 0.072 237.53 RB E NTRY SUPPOR T - ANTEROOM
  • 821008 004869 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.47 RB ENTRY SUPPORT - ANTE ROOM
  • 821008 004869 C20H001 RB SUPPORT ACTIVITY I SE 0.000 0.37 RB ENTRY SUPPORT - ANTEROOM 821008 004870 C20H001 RB SUPPORT ACTIVITY 20 CN 0.412 46.08 RB ENTRY SUPPORT - AIRLOCK 821011 004881 C20H001 RB SUPPORT ACTIVITY I HP 0.035 0.48 RADIATION SURVEY AND HP COVERAGE 821011 004883 C20H001 RB SUPPORT ACTIVITY 13 CN G.000 44.30 OPERATE NLB PUMP / PERFORM MAINT.
  • 821011 004883 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 1.73 OPERATE NLB PUMP / PERFORM MAINT
  • 821011 004883 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.95 OPERATE NLB PUMP / PERFORM MAINT.

821014 004905 C20H001 RB SUPPORT ACTIVITY 1 HP 0.045 0.65 RADIATION SURVEY AND HP COVERAGE 821015 004914 C20H001 RB SUPPORT ACTIVITY 1 RP 0.125 2.03 TOOL AND TRASH REMOVAL

  • 821015 004914 C20H001 RB SUPPORT ACTIVITY 1 UM 0.128 2.05 TOOL AND TRASH REMOVAL 821015 004928 C20H001 RB SUPPORT ACTIVITY 48 CN 0.019 112.26 RB ENTRY SUPPORT - ANTEROOM
  • 821015 004928 C20H001 RB SUPPORT ACTIVITY 26 HP 0.005 145.27 RB E NTRY SUPPORT - ANTE ROOM
  • 821015 004928 C20H001 RB SUPPORT ACTIVITY 2 OP 0.003 1.70 RB ENTRY SUPPORT - ANTERDOM 821015 004929 C20H001 RB SUPPORT ACTIVITY 13 CN 0.196 27.78 RB ENTRY SUPPORT - AIRLOCK 821018 004930 C20H001 RB SUPPORT ACTIVITY 4 CN 1.395 9.28 LIFT RIG INSTALLATION 821018 004932 C20H001 RB SUPPORT ACTIVITY 4 CN 0.784 9.27 MODIFY LIFT RIG 821018 004934 C20H001 RB SUPPORT ACTIVITY 1 HP 0.085 0.75 RADIATION SURVEY AND HP COVERAGE 821018 004937 C20H001 RB SUPPORT ACTIVITY 17 CN 0,000 66.25 OPE R AT E-NL B PUt1P/PE RF ORM MAINT.

yo

  • 821018 004937 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 6.15 OPE RATE NLB PUMP /PE RF ORM MAINT.

Em

  • 821018 004937 C20H001 RB SUPPORT ACTIVITY 2 OP 0.003 2.58 OPERATE NLB PUMP / PERFORM MAINT.

I

  • 821018 004937 C20H001 RB SUPPORT ACTIVITY 2 CM 0.000 0.25 OPERATE NLB PUMP / PERFORM MAINT.

821020 004942 C20H001 RB SUPPORT ACTIVITY I RP 0.120 1.43 TRASH AND TOOL REMOVAL

  • 821020 004942 C20H001 RB SUPPORT ACTIVITY 1 UM 0.120 1.67 TRASH AND TOOL REMOVAL 821020 004944 C20H001 RB SUPPORT ACTIVITY 2 CN 0.339 3.37 MODIFY LIFT RIG 821021 004949 C20H001 RB SUPPORT Act!";T.~

1 HP 0.094 2.08 RADIATION SURVEY /HP COVERAGE 821024 004968 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0,03 OPERATE FS-V-639 821025 004970 C20H001 RB SUPPORT ACTIVITY 14 CN 0.149 26.47 RB ENTRY SUPPORT - AIRLOCK

  • 821025 004970 C20H001 RB SUPPORT ACTIVITY Z OP 0.004 0.48 RB ENTRY SUPPORT - AIRLOCK 821025 004971 C20H001 RB SUPPORT ACTIVITY 53 CN 0.088 143.13 RB ENTRY SUPPORT - ANTEROOM
  • 821025 004971 C20H001 RB SUPPORT ACTIVITY 24 HP 0.010 127.62 RB ENTRY SUPPORT - ANTEROOM 821025 004972 C20H001 RB SUPPORT ACTIVITY 9 CN 0.000 51.42 OPERATE AND MAINTAIN NLB PUMP

$821025 004972 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 5.58 OPERATE AND MAINTAIN NLB PUMP

  • 821025 004972 C20H001 R3 SUPPORT ACTIVITY 2 OP 0.000 3.12 OPERATE AND MAINTAIN NLB PUMP 821025 004989 C20H001 R3 SUPPORT ACTIVITY 1 OP 0.005 0.75 OPERATE FS-V-639
  • 821025 004989 C20H001 R8 SUPPORT ACTIVITY 1 HP 0.015 2.13 OPERATE FS-V-639 821028 004997 C20H001 RB SUPPORT ACTIVITY 2 HP 0.046 1.57 RADIATION SURVEY /HP COVERAGE 821029 005018 C20H001 RB SUPPORT ACTIVITY 13 CN 0.176 29.60 RB ENTRY SUPPORT - AIRLOCK
  • 821029 005018 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.50 RB ENTRY SUPPORT - AIRLOCK 823029 005019 C20H001 RB SUPPORT ACTIVITY 30 CN 0.051 71.15 RB ENTRY SUPPORT - ANTEROOM
  • 821029 005019 C20H001 RB SUPPORT ACTIVITY 18 HP 0.018 109.88 RB ENTRY SUPPORT - ANTEROOM
  • 821029 005019 C20H001 RB SUPPORT ACTIVITY 2 RP 0.013 3.35 RB ENTRY SUPPORT - ANTEROOM
  • 8?!029 005019 C20H001 RB SUPPORT ACTIVITY 1 IC 0.002 0.63 RB ENTRY SUPPORT - ANTEROOM

$821029 005019 C20H001 R8 SUPPORT ACTIVITY 1 OP 0.000 0.12 RB ENTRY SUPPORT - ANTEROOM 821101 005010 C20H001 RB SUPPORT ACTIVITY 1 HP 0.049 0.25 RADIATION SURVFY/HP COVERAGE 821101 005011 C20H001 R8 SUPPORT ACTIVITY 2 RP 0.115 3.12 TRASH AND TOOL REMOVAL 821101 005025 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 16.73 DECON & MAINTENANCE - NLB PUMP

  • 821101 005025 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 2.60 DECON & MAINTENANCE - NLB PUMP 821105 005046 C20H001 RB SUPPORT ACTIVITY 1 CN 0.166 1.82 RAD SURVEY / JOB COVERAGE / TRASH REMOVAL l

1

DATE 022486 PAGE 12 PNO. 11 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. T It1E

  • DATE ACT ENTR

. REM . HOURS TASK DESCRIPTION

  • ....... NUMBER. NUMBER..........IVITY............................CODE................................................................

821108 005057 C20H001 RB SUPPORT ACTIVITY 11 CN 0.178. 25.70 RB ENTRY SUPPORT - AIRLOCK 821108 005058 C20H001 RB SUPPORT ACTIVITY 28 CN 0.050 58.54 RB ENTRY SUPPORT - AN T E R OOM

  • 821108 005058 C20H001 RB SUPPORT ACTIVITY 24 HP 0.010 126.48 RB ENTRY SUPPORT - AN T E R0OM
  • 821108 005058 C20H001 RB SUPPORT ACTIVITY 4 OP 0.000 3.38 RB ENTRY SUPPORT - ANTERDOM 821108 005059 C20H001 RB SUPPORT ACTIVITY I HP 0.125 1.05 RADIATION SURVEY /HP COVERAGE 821108 005071 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 13.10 OPERATE & MAINTAIN NLB PUMP 821110 005079 C20H001 RB SUPPORT ACTIVITY I HP 0.148 1.65 RAD SURVEY /RCS GAS SAMPLE / TRASH REMOVAL
  • 8211i0 005079 C20H001 RB SUPPORT ACTIVITY 1 OP 0.156 1.40 RT.D SURVEY /RCS GAS SAMPLE / TRASH REMOVAL 821112 005093 C20H001 RB SUPPORT ACTIVITY 2 CN 0.183 3.05 INSTALL ELECTRIC WINCHES ON LIFT RIGS 821112 005089 C20H001 RB SUPPORT ACTIVITY 4 HP 1.179 12.35 RAD SURVEY /HP COVERAGE / TRASH REMOVAL 821114 005100 C20H001 RB SUPPORT ACTIVITY 36 CN 0.028 84.03 RB ENTRY SUPPORT - ANTEROOM
  • 821114 005100 C20H001 RB SUPPORT ACTIVITY 31 HP 0.041 173.82 RB ENTRY SUPPORT - ANTEROOM

$821114 005100 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.32 RB ENTRY SUPPORT - ANTEROOM 821114 005101 C20H001 RD SUPPORT ACTIVITY 17 CN 0.316 19.30 RB ENTRY SUPPORT - AIRLOCK 821115 005107 C20H001 RB SUPPORT ACTIVITY 1 HP 0.176 2.25 RAD SURVEY /HP COVERAGE /THASH REMOVAL 821115 005118 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 24.18 OPERATION & MAINT OF NLB PUMP 821118 005130 C20H001 RB SUPPORT ACTIVITY 4 HP 0.445 5.20 R AD SURVEY /HP COVERAGE /TR ASH REMOVAL 821118 005132 C20H001 RB SUPPORT ACTIVITY 4 CN 0.812 7.87 INSULATE ELECTRIC WINCHES - LIFT RIGS 821118 005134 C20H001 RB SUPPORT ACTIVITY 2 CN 0.440 3.42 ADD RECEPTACLES TO power BUGGIES 821122 005158 C20H001 RB SUPPORT ACTIVITY 10 CN 0.066 19.86 RB ENTRY SUPPORT - ANTEROOM

  • 821122 005158 C20H001 RB SUPPORT ACTIVITY 8 HP 0.010 33.42 RB ENTRY SUPPORT - ANTER0OM 8

821122 005162 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 8.13 OPERATE NLB PUMP 005178 C20H001 RB SUPPORT ACTIVITY 26 CN 0.102 56.55 RB ENTRY SUPPORT - AIRLOCKS f *821124 8 1124 005178 C20H001 RB SUPPORT ACTIVITY 27 HP 0.020 130.01 RB ENTRY SUPPORT - AIRLOCKS

  • 821124 005178 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 0.57 RB ENTRY SUPPORT - AIRLOCKS
  • 821124 005178 C20H001 RB SUPPORT ACTIVITY I OP 0.000 0.63 RB ENTRY SUPPORT - AIRLOCKS 821124 005179 C20H001 RB SUPPORT %CTIVITY 11 CN 0.254 26.26 RB ENTRY SUPPORT - AIRLOCK
  • 821124 005179 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.02 RB ENTRY SUPPORT - AIRLOCK 821124 005184 C20H001 RD SUPPORT ACTIVITY I CN 0.150 0.88 RADIATION SURVEYS
  • 821124 005184 C20H001 RB SUPPORT ACTIVITY

! HP 0.105 1.02 RADIATION SURVEYS 821124 005185 C20H001 RB SUPPORT ACTIVITY 2 RP 0.407 4.30 (NO TASK DESCRIPTION) 821128 005206 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 30.07 OPERATION & MAINT OF NLB PUMP

  • 821128 005206 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.63 OPERATION & MAINT OF NLB PUMP 821129 005194 C20H001 RB SUPPORT ACTIVITY 1 HP 0.108 2.27 RADIATION SURVEY /HP COVERAGE 821129 005195 C20H001 RB SUPPORT ACTIVITY 2 CN 0.371 3.70 TRASH AND TOOL REMOVAL 821201 005216 C20H001 RB SUPPORT ACTIVITY I HP 0.105 1.15 RADIATION SURVEY FOR TRASH REMOVAL 821202 005227 C20H001 RB SUPPORT ACTIVITY 16 CN 0.254 32.23 RB ENTRY SUPPORT - AIRLOCK
  • 821202 005227 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 7.45 RB ENTRY SUPPORT - AIRLOCK 821202 005228 C20H001 RB SUPPORT ACTIVITY 41 CN 0.002 85.25 RB ENTRY SUPPORT - ANTEROOM
  • 821202 005228 C20H001 RB SUPPORT ACTIVITY 33 HP 0.012 180.08 RB ENTRY SUPPORT - ANTER0OM
  • 821202 005228 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.70 RB ENTRY SUPPORT - ANTEROOM 821206 005248 C20H001 RB SUPPORT ACTIVITY 1 HP 0.060 0.82 RADIATION SURVEY FOR TRASH REMOVAL 821206 005251 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 23.50 OPERATION AND MAINT OF NLB PUMP
  • 821206 005251 C20H001 RB SUPPORT ACTIVITY 2 OP 0.005 0.67 OPERATION AND MAINT OF NLB PUMP 821208 005269 C20H001 RB SUPPORT ACTIVITY 3 CN 0.495 6.50 REMOTE DECON OF 282* LEVEL 821208 005280 C20H001 RB SUPPORT ACTIVITY 15 CN 0.223 32.90 RB ENTRY SUPPORT - AIRLOCK 821208 005281 C20H001 RB SUPPORT ACTIVITY 44 CN 0.098 89.14 RB ENTRY SUPPORT - ANTEROOM
  • 821208 005281 C20H001 RB SUPPORT ACTIVITY 37 HP 0.045 208.55 RB ENTRY SUPPORT - ANTE ROOM
  • 821208 005281 C20H001 RB SUPPORT ACTIVITY 3 SE 0.000 2.00 RB ENTRY SUPPORT - ANTER0OM
  • 821208 005281 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 1.03 RB ENTRY SUPPORT - ANTEROOM

DATE 022486 PAGE 13 PNO. 12 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..... CODE.......,......,..........................C.RIPTI.ON . REM . HOURS. TASK DES s....E... NUMBE R. NUMBE. R..............IVIT.Y................ E.NTR

  • DAT ACT
  • 821208 005281 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.63 RB ENTRY SUPPOR T - ANTEROOM 821216 005337 C20H001 RB SUPPORT ACTIVITY 18 CN 0.283 40.34 RB ENTRY SUPPORT - AIRLOCK

.*821216 005337 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 0.68 RB ENTRY SUPPORT - AIRLOCK 821217 005351 C20H001 RB SUPPORT ACTIVITY 2 HP 0.383 2.90 RADIATION SURVEY - NEUT SHIELD TANKS 821217 005356 C20H001 RB SUPPORT ACTIVITY 8 OP 0.000 17.50 TRANSFER WATER - PWST-2 & BWST

  • 821217 005356 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 4.52 TRANSFER WATER - PWST-2 & BWST 821220 005360 C20H001 RB SUPPORT ACTIVITY 1 EL 0.083 1.25 TOOL AND EQUIPMENT REMOVAL
  • 821220 005360 C20H001 RB SUPPORT ACTIVITY I RP 0.061 1.47 TOOL AND EOU!PMENT REMOVAL 821220 005376 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 16.92 OPERATION AND MAINT OF NLB PUMP 821222 005386 C20H001 RB SUPPORT ACTIVITY 1 HP 0.058 0.77 RADIATION SURVEY - SERVICE STRUCTURE 821223 005391 C20H001 RB SUPPORT ACTIVITY 32 CN 0,024 51.08 RB ENTRY SUPPORT - ANTEROOM
  • 821223 005391 C20H001 RB SUPPORT ACTIVITY 22 HP 0.025 111.33 RB ENTRY SUPPORT - ANTEROOM
  • 821223 005391 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 0.42 RB ENTRY SUPPORT - ANTEROOM
  • 821223 005391 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.95 RB ENTRY SUPPORT - ANTEROOM 821223 005392 C20H001 RB SUPPORT ACTIVITY 9 CN 0.155 16.72 RB ENTRY SUPPORT - AIRLOCK 821227 005409 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 24.07 OPERATION AND MAINT OF NLB PUMP 821229 005431 C20H001 RB SUPPORT ACTIVITY I HP 0.027 0.83 INVESTIGATE FIRE ALARM
  • 821229 005431 C20H001 RB SUPPORT ACTIVITY

! OP 0.026 0.80 INVESTIGATE FIRE ALARM 821230 005435 C20H001 RB SUPPORT ACTIVITY 10 CN 0.138 21.28 RB ENTRY SUPPORT - AIRLOCK 8 821230 005436 C20H001 RB SUPPORT ACTIVITY 28 CN 0.000 57.60 RB ENTRY SUPPORT - ANTERDOM M3 *821230 005436 C20H001 RB SUPPORT ACTIVITY 29 HP 0.013 145.45 RB ENTRY SUPPORT - ANTEROOM Ch

  • 821230 005436 C20H001 RB SUPPORT ACTIVITY 1 RP 0.008 1.12 RB ENTRY SUPPORT - ANTEROOM 830103 005465 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 23.68 OPERATION AND MAINT OF NLB PUMP 830104 005459 C20H001 RB SUPPORT ACTIVITY 3 CN 0.463 5.40 TRASH REMOVAL 830104 005460 C20H001 RB SUPPORT ACTIVITY 2 RP 0.291 4.60 TOOL INVENTORY AND SORTING 830106 005488 C20H001 RB SUPPORT' ACTIVITY 10 CN 0.105 21.20 RB ENTRY SUPPORT - AIRLOCK 830106 005489 C20H001 RB SUPPORT ACTIVITY 46 CN 0.033 93.42 RB ENTRY SUPPORT - ANTEROOM
  • 830106 005489 C20H001 RB SUPPORT ACTIVITY 53 HP 0.006 221.03 RB ENTRY SUPPORT - ANTEROOM
  • 830106 005489 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 3.02 RB ENTRY SUPPORT - ANTEROOM 830110 005522 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 33.50 OPERATION AND MAINT OF NLB PUMP 830111 005537 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 0.93 MEASUREMENT FOR AIRLOCK FALSE FLOOR 830111 005532 C20H001 RB SUPPORT ACTIv1TY 16 CN 0.194 34.67 RB ENTRY SUPPORT - AIRLOCK 830113 005554 C20H001 RB SUPPORT ACTIVITY 21 CN 0.023 35.16 RB ENTRY SUPPORT - ANTERDOM

$830113 005554 C20H001 RB SUPPORT ACTIVITY 19 HP 0.000 85.92 RB ENTRY SUPPORT - ANTER0OM

  • 830113 005554 C20H001 RB SUPPORT ACTIVITY 2 AD 0.000 0.20 RB ENTRY SUPPORT - ANTER0OM
  • 830113 005554 C20H001 RB SUPPORT ACTIVITY 1 VI 0.000 0.05 RB ENTRY SUPPORT - ANTERDOM 830117 005580 C20H001 RB SUPPORT ACTIVITY 3 CN 0.044 5.90 RB ENTRY SUPPORT - AIRLOCK 830117 005592 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 33.58 OPERATE AND MAINTAIN NLB PUMP 830117 005881 C20H001 RB SUPPORT ACTIVITY 41 CN 0.023 68.88 RB ENTRY SUPPORT - ANTER0OM
  • 830117 005881 C20H001 RB SUPPORT ACTIVITY 32 HP 0.015 176.83 RB ENTRY SUPPORT - ANTEROOM
  • 830117 005881 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.67 RB ENTRY SUPPORT - ANTEROOM 830118 005608 C20H001 RB SUPPORT ACTIVITY 12 CN 0.139 25.37 RB ENTRY SUPPORT - AIRLOCK 830124 005651 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 11.22 DECON U-! TO U-2 CORRIDOR 830124 005637 C20H001 RB SUPPORT ACTIVITY 22 CN 0.275 41.25 RB ENTRY SUPPORT - AIRLOCK 830124 005638 C20H001 RB SUPPORT ACTIVITY 54 CN 0.019 95.88 RB ENTRY SUPPORT - ANTER0OM
  • 830124 005638 C20H001 RB SUPPORT ACTIVITY 40 HP 0.020 174.18 RB E NTRY SUPPORT - ANTE ROOM
  • 830124 005638 C20H001 RB SUPPORT ACTIVITY 2 OP 0.003 3.52 RB E NTRY SUPPOR T - ANTER0OM 830131 005695 C20H001 RB SUPPORT ACTIVITY 59 CN 0.017 134.40 RB ENTRY SUPPORT - ANTEROOM
  • 830131 005695 C20H001 RB SUPPORT ACTIVITY 27 HP 0.015 145.25 RB ENTRY SUPPORT - ANTER0OM
  • 830131 005695 C20H001 RD SUPPORT ACTIVITY 1 OP 0.003 5.33 RB ENTRY SUPPORT - ANTER0OM

DATE 022486 PAGE 14 PNO. 13 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER
  • =............. NUMBER.....................ITY ACTIV ENTR. CODE. REM

. HOURS TASK DESCRIPTION 830131 005696 C20H001 RB SUPPORT ACTIVITY 17 CN 0.183 28.95 RB ENTRY SUPPORT - AIRLOCK

  • 830131 005696 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 0.83 RB ENTRY SUPPORT - AIRLOCK 830131 005697 C20H001 RB SUPPORT ACTIVITY 20 ON 0.112 40.91 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830131 005697 C20H001 RB SUPPORT ACTIVITY 5 HP 0.000 12.80 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830131 3c5697 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.92 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830131 005710 C20H001 RR SUPPORT ACTIVITY 2 CN 0.000 5.98 OPERATION & MAINTENANCE OF NLB PUMP 830202 005723 C20H001 RB SUPPORT ACTIVITY 3 CN 0.254 4.83 RELOCATE SPIDER
  • 830202 005723 C20H001 RB SUPPORT ACTIVITY 1 EL 0.100 1.72 RELOCATE SPIDE R 830207 005755 C2CHL01 RB SUPPORT ACTIVITY 50 CN 0.059 98.41 RB ENTRY SUPPORT - ANTEROOM
  • 830207 005755 C20H001 RB SUPPORT ACTIVITY 42 HP 0.051 246.17 RB ENTRY SUPPORT - ANTEROOM
  • 830207 005755 C20H001 RB SUPPORT ACTIVITY 3 OP 0.010 10.17 RB ENTRY SUPPORT - ANTEROOM
  • 830207 005755 C20H001 RB SUPPORT ACTIVITY 2 RP 0.000 8.25 RB ENTRY SUPPORT - ANTEROOM 830207 005759 C20H001 RB SUPPORT ACTIVITY 23 CN 0.288 42.42 RB ENTRY SUPPORT - DERSONNEL AIRLOCK 830207 005760 C20H001 RB SUPPORT ACTIVITY 6 CN 0.028 10.29 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830207 005760 C20H001 RB SUPPORT ACTIVITY 2 HP 0.005 1.78 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830207 005760 C20H001 RB SUPPORT ACTIVITY 1 MM 0.004 0.55 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830207 005767 C20H001 RB SUPPORT ACTIVITY 6 CN 0.003 34.48 OPERATION AND MAINTENANCE OF NLB PUMP
  • 830207 005767 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 0.87 OPERATION AND MAINTENANCE OF NLB PUMP
  • 830207 005767 C20H001 RB SUPPORT ACTIVITY 1 OP 0.002 0.37 OPERATION AND MAINTENANCE OF NLB PUMP i

830210 005791 C20H001 RB SUPPORT ACTIVITY 3 RP 0.607 7.67 TRASH'AND TOOL REMOVAL yo $830210 005791 C20H001 RB SUPPORT ACTIVITY 1 BS 0.187 1.98 TR ASH AND TOOL REMOVAL %4

  • 830210 005791 C20H001 RB SUPPORT ACTIVITY 1 HP 0.060 3.70 TR ASH AND TOOL REMOVAL 8

830211 005803 C20H001 RB SUPPORT ACTIVITY 1 CN 0.002 0.33 INSTALL FITTING ON EMERGENCY AIR SUPPLY 830211 005805 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 11.50 DECON NLB PUMP ENCLOSURE 830214 005815 C20H001 RB SUPPORT ACTIVITY 3 CN 0.486 8.92 CLEAN POLAR CRANE 830214 005816 C20H001 RB SUPPORT ACTIVITY 21 CN 0.283 42.30 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830214 005818 C20H001 RB SUPPORT ACTIVITY 48 CN 0.034 92.61 RB ENTRY SUPPORT - AIRLOCK

  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 45 HP 0.069 240.12 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 5 SE 0.000 3.87 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 2.75 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 4 RP 0.025 9.83 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 1.50 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 2 MM 0.000 1.70 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 3 CM 0.000 4.32 RB ENTRY SUPPORT - AIRLOCK
  • 830214 005818 C20H001 RB SUPPORT ACTIVITY 1 AM 0.000 0.20 RB ENTRY SUPPORT - AIRLOCK 830214 095819 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 35.63 OPERATE AND MAINTAIN NLB PUMP 830215 005833 C20H001 RB SUPPORT ACTIVITY 1 EL 0.196 1.70 TRASH AND TOOL REMOVAL
  • 830215 005833 C20H001 RB SUPPORT ACTIVITY 1 OP 0.139 1.83 TRASH AND TOOL REMOVAL
  • 830215 005833 C20H001 RB SUPPORT ACTIVITY

! CM 0.206 1.69 TRASH AND TOOL REMOVAL 830215 005836 C20H001 RB SU/ PORT ACTIVITY 3 RP 0.444 5.72 REMOVE SERVICE STRUCTURE FANS 3830215 005836 C20H001 RB SUPPORT ACTIVITY 1 HP 0.115 1.95 REMOVE SERVICE STRUCTURE FANS 830217 005856 C20H001 RB SUPPORT ACTIVITY 4 CN 0.502 9.53 PREPARE POLAR CRANE FOR TESTING 830218 005865 C20H001 RB SUPPORT ACTIVITY 1 CN 0.010 1.70 FUNCTIONAL CHECK OF EQUIP HATCH DOORS

  • 830218 005865 C20H001 RB SUPPORT ACTIVITY 1 OP 0.005 0.63 FUNCTIONAL CHECK OF EQUIP HATCH DOORS
  • 830218 005865 C20H001 RB SUPPORT ACTIVITY 1 MD 0.008 2.60 FUNCTIONAL CHECK OF EQUIP HATCH DOORS
  • 830218 005865 C20H001 RB SUPPORT ACTIVITY 1 IC 0.005 1.35 FUNCTIONAL CHECK OF EQUIP HATCH DOORS 830221 005892 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 27.12 OPERATE AND MAINTAIN NLB PUMP 830222 005874 C20H001 RB SUPPORT ACTIVITY 38 CN 0.023 57.46 RB ENTRY SUPPORT
  • 830222 005874 C20H001 RB SUPPORT ACTIVITY 28 HP 0.014 131.83 RB E NTRY SUPPORT
  • 830222 005874 C20H001 RB SUPPORT ACTIVITY 4 OP 0.000 2.08 RB ENTRY SUPPCRT

_~ -. l I .i 1 DATE 022486 PAGE 15 PNO. 14 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • ...TE.. NUMBER. NUMBER...................IVIT.Y

................................. HOURS....................D. E.S.C. R I P T. I ON

  • DA ACT..

. ENTR. CODE. REM TASK ......................i..

  • 830222 005874 C20H001 RB SUPPORT ACTIVITY 1 SE 0.000 0.82 RB ENTRY SUPPORT
  • 830222 005874 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 2.70 RB ENTRY SUPPORT

$830222 005874 C20H001 RB SUPPORT ACTIVITY 1 MM 0.000 2.63 RB ENTRY SUPPORT

  • 830222 005874 C20H001 RB SUPPORT ACTIVITY 1 RC 0.000 0.68 RB ENTRY SUPPORT 830222 005875 C20H001 RB SUPPORT ACTIVITY 15 CN 0.159 27.48 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830222 005876 C20H001 RB SUPPORT ACTIVITY 2 CN 0.030 4.27 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830222 005876 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 0.90 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK i
  • 830222 005876 C20H001 RB SUPPORT ACTIVITY I HP 0.000 0.68 RR ENTRY SUPPORT - EQUIPMENT AIRLOCK 830224 005917 C20H001 RB SUPPORT ACTIVITY 1 UM 0.194 2.15 TRASH AND TOOL REMOVAL
  • 830224 005917 C20H001 RB SUPPORT ACTIVITY 1 MM 0.211 1.98 TR ASH AND TOOL REMOVAL 830228 005944 C20H001 RB SUPPORT ACTIVITY 56 CN 0.011 269.28 DISMANTLE / ERECT CONT CNTRL CORR /DECON
  • 830228 005944 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 6.87 DISMANTLE / ERECT CONT CNTRL CORR /DECON 830228 005948 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 8.72 OPERATE AND MAINTAIN NLB PUMP 830302 005956 C20H001 RB SUPPORT ACTIVITY 7 CN 0.000 13.19 RB ENTRY SUPPORT - ANTER0OM
  • 830302 005956 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.18 RB ENTRY SUPPORT - ANTEROOM 4

I

  • 830302 005956 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 1.10 RB ENTRY SUPPORT - ANTER0OM i

830302 005957 C20H001 RB SUPPORT ACTIVITY 18 CN 0.107 0.00 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK

  • 830302 005957 C20H001 RB SUPPORT ACTIVITY 4 HP 0.000 11.38 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830302 005957 C20H001 RB SUPPORT ACTIVITY I RC 0.000 4.48 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK e

830304 005983 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 4.48 DECON AREA OVER EQUIPMENT HATCH 4D 830307 005988 C20H001 RB SUPPORT ACTIVITY 26 CN 0.014 80.82 RB ENTRY SUPPORT - ALL AREAS 00 8830307 005988 C20H001 RB SUPPORT ACTIVITY 26 HP 0.019 153.54 RB ENTRY SUPPORT - ALL AREAS 8 *830307 005988 C20H001 RB SUPPORT ACTIVITY 3 OP 0.013 3.70 RB ENTRY SUPPORT - ALL AREAS

  • 830307 005988 C20H001 RB SUPPORT ACTIVITY 3 MM 0.012 4.67 RB ENTRY SUPPORT - ALL AREAS
  • 830307 005988 C20H001 RB SUPFORT ACTIVITY 1 UM 0.000 0.25 RB ENTRY SUPPORT - ALL AREAS 830307 C05989 C20H001 -RB SUPPORT ACTIVITY 47 CN 0.265 85.35 RB ENTRY SUPPORT - EQUIPMENT HATCH
  • 830307 005989 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.05 RB ENTRY SUPPORT - EQUIPMENT HATCH 4
  • 83030T 005989 C20H001 RB SUPPORT ACTIVITY 3 MM 0.005 1.70 RB ENTRY SUPPORT - EQUIPMENT HATCH
  • 830307 005989 C20H001 RB SUPPORT ACTIVITY 3 HP 0.000 4.35 RB ENTRY SUPPORT - EQUIPMENT HATCH 830307 006005 C20H001 RB SUPPOR T ACTIVITY 9 CN 0.012 34.82 OPERATE AND MAINTAIN NLB PUMP 830309 006018 C20H001 RB SUPPORT ACTIVITY 1 EL 0.216 1.85 TOOL INVENTORY AND CONTROL 2830309 006018 C20H001 RB SUPPORT ACTIVITY 2 UM 0.677 4.02 TOOL INVENTORY AND CONTROL 2830309 006018 C20H001 RB SUPPORT ACTIVITY 1 MM 0.200 1.85 TOOL INVENTORY AND CONTROL
  • 830309 006018 C20H001 RB SUPPORT ACTIVITY 1 RP 0.354 2.12 TOOL INVENTORY AND CONTROL i

830314 006036 C20H001 RB SUPPORT ACTIVITY 4 CN 0.017 6.42 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK

  • 830314 006036 C20H001 RB SUPPORT ACTIVITY 3 MM 0.011 4.95 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830314 006037 C20H001 RB SUPPORT ACTIVITY 20 CN 0.201 41.50 RB ENTRY SUPPORT - PERSONNEL AIRLOCK

$830314 006037 C20H001 RB SUPPORT ACTIVITY 1 HP 0.000 1.12 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830314 006038 C20H001 RB SUPPORT ACTIVITY ' 93 CN 0.022 261.34 RB ENTRY SUPPORT - ALL AREAS

  • 830314 006038 C20H001 RB SUPPORT ACTIVITY 32 HP 0.006 178.47 RB ENTRY SUPPORT - ALL AREAS
  • 830314 006038 C20H001 -RB SUPPORT ACTIVITY 2 OP 0.000 2.48 RB ENTRY SUPPORT - ALL AREAS
  • 830314 006038 C20H001 RB SUPPORT ACTIVITY 1 AM 0,000 0.28 RB ENTRY SUPPORT - ALL AREAS 4

830314 006050 C20H001 RB SUPPORT ACTIVITY 14 CN 0.005 44.08 OPERATE AND MAINTAIN NLB PUMP J 830319 081739 C20H001 RB SUPPORT ACTIVITY 1 CR O.005 0.00 CLEAN PERSONNEL AIRLOCK

  • 830319 0B1739 C20H001 RB SUPPORT ACTIVITY 5 CN 0,150 6.42 CLEAN PERSONNEL AIRLOCK 830321 006091 C20H001 RB SUPPORT ACTIVITY 14 CN 0.106 29.13 RB ENTRY SUPPORT - PERSONNEL AIRLOCK B30321 006092 C20H001 RB SUPPORT ACTIVITY 63 CN 0.012 144.95 RB ENTRY SUPPORT - ALL AREAS
  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 30 HP 0.006 146.27 RB ENTRY SUPPORT - ALL AREAS

-*830321 006092 C20H001 RB SUPPORT ACTIVITY 1 AD 0.000 0.27 RB ENTRY SUPPORT - ALL AREAS

  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 1 AM 0.005 0.28 RB ENIRY SUPPORT - ALL AREAS

DATE 022486 PAGE 16 FNO. 15 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER............................................... CODE........ REM........ HOURS.........................................................,

ACTIVITY . ENTR TASK DESCRIPTION

  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 1 MD 0.000 0.08 RB ENTRY SUPPORT - ALL ARE AS
  • 830321 006092 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.93 RB ENTRY SUPPORT - ALL AREAS 830321 006107 C20H001 RB SUPPORT ACTIVITY 9 CN 0.000 38.27 OPERATE AND MAINTAIN NLB PUMP
  • 830321 006107 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.50 OPERATE AND MAINTAIN NLB PUMP 830321 006085 C20H001 RB SUPPORT ACTIVITY 5 CN 0.047 11.35 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830322 006120 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 5.52 REMOVE BLIND FLnNGE/ INSTALL VALVE 830322 006121 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 2.53 REMOVE BLIND FLANGE / INSTALL VALVE 830328 006147 C20H001 RB SUPPORT ACTIVITY 56 CN 0.047 132.62 RB ENTRY SUPPORT - ALL CONTROLLED AREAS
  • 830328 006147.C20H001 RB SUPPORT ACTIVITY 20 HP 0.015 124.20 RB ENTRY SUPPORT - ALL CONTROLLED ARE AS
  • 830328 006147 C20H001 RB SUPPORT ACTIVITY 4 RC 0.014 26.52 RB ENTRY SUPPORT - ALL CONTROLLED AREAS
  • 830328 006147 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.63 RB ENTRY SUPPORT - ALL CONTROLLED AREAS 4830328 006147 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 0.45 RB ENTRY SUPPORT - ALL CONTROLLED AREAS 830328 006148 C20H001 RB SUPPORT ACTIVITY 12 CN 0.076 21.00 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830328 006150 C20H001 RB SUPPORT ACTIVITY 6 CN 0.005 34.67 OPERATE AND MAINTAIN NLB PUMP 830328 006161 C20H001 RB SUPPORT ACTIVITY 2 CN 0.289 3.22 TRASH REMOVAL 830329 006163 C20H001 RB SUPPORT ACTIVITY 2 CN 0.491 5.52 TRASH AND TOOL REMOVAL 830404 006201 C20H001 RB SUPPORT ACTIVITY 7 CN 0.006 10.90 OPERATE AND MAINTAIN NLB PUMP 830405 006209 C20H001 RB SUPPORT ACTIVITY 6 CN 0.054 11.07 RB ENTRY SUPPORT - PERSONNEL AIRLOCK
  • 830405 006209 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.88 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830405 006210 C20H001 RB SUPPORT ACTIVITY 41 CN 0.027 107.72 RB ENTRY SUPPORT - ALL ARE AS I
  • 830405 006210 C20H001 RB SUPPORT ACTIVITY 16 HP 0.002 75.58 RB ENTRY SUPPORT - ALL AREAS ua *830405 006210 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.32 RB ENTRY SUPPORT - ALL AREAS WD *830405 006210 C20H001 RB SUPPORT ACTIVITY 1 CM 0.000 1.45 RB ENTRY SUPPORT - ALL AREAS
  • 830405 006210 C20H001 RB SUPPORT ACTIVITY 1 AM 0.000 0.08 RB ENTRY SUPPORT - ALL AREAS
  • 830405 006210 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 2.63 RB ENTRY SUPPORT - ALL AREAS 830405 006211 C20H001 RB SUPPORT ACTIVITY 1 CN 0.021 3.32 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830411 006241 C20H001 RB SUPPORT ACTIVITY 2 CN 0.356 3.93 SURVEY FOR TRASH REMOVAL / PHOTOGRAPHS 830411 006243 C20H001 RB SUPPORT ACTIVITY 3 CN 0.031 5.03 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830411 006244 C20H001 RB SUPPORT ACTIVITY 6 CN 0.070 12.00 RB ENTRY SUPPORT - PERSONNEL AIRLOCK
  • 830411 006244 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.50 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830411 006245 C20H001 RB SUPPORT ACTIVITY 37 CN 0.069 93.80 RB ENTRY SUPPORT - ALL AREAS
  • 330411 006245 C20H001 RB SUPPORT ACTIVITY 14 HP 0.022 46.88 RB ENTRY SUPPORT - ALL AREAS
  • 830411 006245 C20H001 RB SUPPORT ACTIVITY 2 SE 0.000 1.22 RB ENTRY SUPPORT - ALL AREAS
  • 830411 006245 C20H001 RB SUPPORT ACTIVITY 1 RC 0.000 4.13 RB ENTRY SUPPROT - ALL AREAS
  • 830411 006245 C20H001 RB SUPPORT ACTIVITY 2 CM 0.000 2.52 RB ENTRY SUPPORT - ALL AREAS 830411 006260 C20H001 RB SUPPORT ACTIVITY 4 CN 0.009 20.17 OPERATE AND MAINTAIN NLB PUMP 830415 006274 C20H001 RB SUPPORT ACTIVITY 4 RP 0.016 8.75 REMOVE TRASH - ANTEROOM TO SFC ROOM
  • 830415 006274 C20H001 RB SUPPORT ACTIVITY 1 BS 0.005 1.32 REMOVE TRASH - ANTEROOM TO SFC ROOM 830415 006276 C20H001 RB SUPPORT ACTIVITY 3 CN 0.558 6.42 TRASH AND P.C. BRAKES REMOVAL 830415 006280 C20H001 RB SUPPORT ACTIVITY 1 RP 0.055 1.12 TRASH REMOVAL 830418 006297 C20H001 RB SUPPORT ACTIVITY 5 CN 0.005 7.78 OPERATE AND MAINTAIN NLB PUMP 830421 006311 C20H001 RB SUPPORT ACTIVITY 18 CN 0.019 40.26 RB ENTRY SUPPORT - ALL AREAS
  • 830421 006311 C20H001 RB SUPPORT ACTIVITY 8 HP 0.005 36.32 RB ENTRY SUPPORT - ALL AREAS 830421 006312 C20H001 RB SUPPORT ACTIVITY 4 CN 0.037 6.80 RB ENTRY SUPPORT - AIRLOCK 830421 006313 C20H001 RB SUPPORT ACTIVITY Z CN 0.005 1.72 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830425 006344 C20H001 RB SUPPORT ACTIVITY 10 CN 0.000 30.15 OPERATE AND MAINTAIN NLB PUMP 830427 006352 C20H001 RB SUPPORT ACTIVITY 60 CN 0.029 147.97 RB ENTRY SUPPORT - ALL AREAS
  • 830427 006352 C20H001 RB SUPPORT ACTIVITY 20 HP 0.010 81.90 RB ENTRY SUPPORT - ALL AREAS
  • 830427 006352 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.23 RB ENTRY SUPPORT - ALL AREAS 830427 006353 C20H001 RB SUPPORT ACTIVITY 20 CN 0.179 38.99 RB ENTRY SUPPORT - PERS & EQUIP AIRLOCKS

= -. _..- ..-_=~-___~- - ~ - - - - ~. i t s DATE 022486 PAGE 17 I i PNO. 16 .TMI-2 UNC: -DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME .......................TAS.K D.E.SCRIPTIO.N . HOURS.

  • .D. ATE.. NU.MBE.R. huMBE.R............. I V..I T Y.......

........E.NTR..... C OD. E... R E.M ACT t 1

  • 830427 006353 C20H001 RB SUPPORT ACTIVITY 2 HP 0.000 15.18 RB ENTRY SUPPORT - PERS & EQUIP AIRLOCKS, i
  • 830427 006353 C20H001 R8 SUPPORT ACTIVITY 1 OP 0.000 0.08

'RB ENTRY SUPPORT - PERS & EQUIP AIRLOCKS i 830427 006355 C20H001 RB SUPPORT ACTIVITY 2 CN 0.471 4.23 FIRE DETECTION SYSTEM WALKDOWN ,330429 006378 C20H001 RB SUPPORT ACTIVITY 1 IC 0.126 1.40 TOOL INVENTORY AND CONTROL $830419 006378 C20H001 RB SUPPORT ACTIVITY 1 UM 0.165 1.32 TOOL INVENTORY AND CONTROL j' 830502 006399 C20H001 RB SUPPORT ACTIVITY 94 CN 0.043 223.04 RB ENTRY SUPPORT - ALL AREAS

  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 28 HP 0.015 138.95 RB ENTRY SUPPORT'- ALL AREAS
  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 2 OP 0.000 1.93 RB ENTRY SUPPORT - ALL AREAS I
  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 3 RP 0.020 9.93 RB ENTRY SUPPORT - ALL AREAS
  • 830502 006399 C20H001 RB SUPPORT ACTIVITY 1 IC 0.000 0.37 RB ENTRY SUPPORT - ALL AREAS 830502 006400 C20H001 RB SUPPORT ACTIVITY 15 CN 0.123 29.10 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830502 006401 C20H001 RB SUPPORT ACTIVITY 4 CN 0.035 7.63 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830502 006404 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 27.59 OPERATE AND MAINTAIN NLB PUMP
  • 830502 006404 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.53 OPERATE AND MAINTAIN NLB PUMP 830502 006405 C20H001 RB SUPPORT ACTIVITY 11 CN 0.094 32.85 REMOVE SPOOL / INSTALL HOSE 830504 006425 C20H001 RB SUPPORT ACTIVITY 3 CN 0.599 6.05 TRASH REMOVAL /DECON INSPECTION 830505 006431 C20H001 RB SUPPORT ACTIVITY 2 CN 0.425 5.15 INSPECTION - ALL LEVELS AND D RINGS l
  • 830505 006431 C20H001 RB SUPPORT ACTIVITY 1 HP 0.135 2.62 INSPECTION - ALL LEVELS AND D RINGS 830509 006461 C20H001 RB SUPPORT ACTIVITY 13 CN 0.016 69.93 OPERATE AND MAINTAIN NLB PUMP j

e 830509 006447 C20H001 RB SUPPORT ACTIVITY 15 CN 0.119 27.23' R8 ENTRY SUPPORT - PERSONNEL AIRLOCK -d 830509 006448 C20H001 RB SUPPORT ACTIVITY 64 CN 0.053 164.17 RB ENTRY SUPPORT - ANTERDOM & AIRLOCKS C3 *830509 006448 C20H001 RB SUPPORT ACTIVITY 22 HP 0.053 93.15 RB ENTRY SUPPORT - ANTEROOM & AIRLOCKS C3 8830509 006448 C20H001 RB SUPPORT ACTIVITY 3 OP 0.005 - 3.70 RB ENTRY SUPPORT - ANTER0OM & AIRLOCKS 4 8 830509 006449 C20H001.RB SUPPORT ACTIVITY-3 CN 0.005 6.73 R8 ENTRY SUPPORT - EQUIPMENT AIRLOCK 830512 006480 C20H001 RB SUPPORT ACTIVITY 1 AM 0.186 2.02 CONTAINMENT SAFETY WALKDDWN s Il ' 2830512 006480 C20H001 RB SUPPORT ACTIVITY 1 CN 0.164 2,07 CONTAINMENT SAFETY WALK 0DWN f 830512 006483 C20H001 RB SUPPORT ACTIVITY 18 CN 3.704 44.42 EQUIPMENT AND TRASH REMOVAL 830513 006491 C20H001 PB SUPPORT ACTIVITY 3 RP. 0.058 6.15 TRASH REMOVAL - EQUIPMENT HATCH 830513 006493 C20H001 RB SUPPORT ACTIVITY 8 CN 2.040 17.58 EQUIPMENT AND TRASH REMOVAL i 830513 006499 C20H001 RB SUPPORT ACTIVITY 3 CN 0.183 3.73 ENCLOSE STAIR SCAFFOLD i i 830516 006505 C20H001 RB SUPPORT ACTIVITY 2 CN 0.590 4.55 TRASH AND EQUIPMENT REMOVAL 830516 006517 C20H001 RB SUPPORT ACTIVITY 5 CN 0.000 26.48 OPERATE AND MAINIAIN NLB PUMP 830516 006500 C20H001 RB SUPPORT ACTIVITY 3 CN O'.026 10.12 R8 ENTRY SUPPORT - EQUIPMENT AIRLOCK $830516 006500 C20H001 RB SUPPORT ACTIVITY 6 RP 0.092 14.46 R8 ENTRY SUPPORT - EQUIPMENT AIRLOCK 830516 006501-C20H001 RB SUPPORT ACTIVITY 23 CN-0.147 36.93 RB ENTRY SUPPORT - PERSONNEL AIRLOCK i

  • 830516 006501 C20H001 R8 SUPPORT ACTIVITY 1 HP 0.000 5.90 RB ENTRY SUPPORT - PE RSONNE L AIRLOCK 830516 006502 C20H001 R8 SUPPORT ACTIVITY 1 CN 0.110 1.40 MEASURE WIRE ROPE /TAKE PHOTOS i

830516 006503 C20H001 RB SUPPORT ACTIVITY 85 CN 0.086 210.72 RB ENTRY SUPPORT - ALL AREAS ~

  • 830516 006503 C20H001 RB SUPPORT ACTIVITY 28 HP 0.086 137.18 RB ENTRY SUPPORT - ALL AREAS
  • 830516 006503 C20H001 R8 SUPPORT ACTIVITY 1 RP.

0.013 2.78 RB ENTRY SUPPORT - ALL AREAS 'i

  • 830516 006503 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.00.

RB ENTRY SUPPORT - ALL AREAS 830517 006527 C20H001 RB SUPPORT ACTIVITY 1 IC 0.194 1.60' TRASH AND EQUIPMENT REMOVAL $830517 006527 C20H001 R8 SUPPORT ACTIVITY 1 MM 0.147 1.58-TRASH AND EQUIPMENT REMOVAL 830517 006528 C20H001-RB SUPPORT ACTIVITY ! CN 0.150 1.67 INSPECTION - ALL LEVELS AND CANAL 830518 006530 C26H001 RB SUPPORT. ACTIVITY 3 CN 0.793 6.52 MOVE FRAMED ENCLOSURE 830518 006532 C2 H001 RB SUPPORT ACTIVITY 9 CN 1.394 18.08 TRASH AND EQUIPMENT REMOVAL 830519 006539 C2CH001 R8 SUPPORT ACTIVITY 2 CN 0.602 5.03 TRASH AND TOOL REMOVAL 830520 006547 C20H001 RB SUPPORT ACTIVITY 2 CN 0.225 2.67 SAFETY AND HOUSEKEEPING INSPECTION 830523 006570 C20H001 RB SUPPORT ACTIVITY .79 CN 0.044 193.56 RB ENTRY SUPPORT

  • 830523 006570 C20H001 RB SUPPORT ACTIVITY 19 HP 0.007 107.60 RB ENTRY SUPPORT

DATE 022486 PAGE 18 PNO. 17 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME . CODE . HOURS TASK DESCRIPTION ........ REM

  • DATE. NUMBER ACTIVITY ENTR
  • .............. NUMBER.............................................
  • 830523 006570 C20H001 RB SUPPORT ACTIVITY 2 RP 0.000 3.77 RB ENTRY SUPPORT 830523 006571 C20HC01 RB SUPPORT ACTIVITY 1 CN 0.011 3.07 RB ENIRY SUPPORT - EQUIPMENT AIRLOCK
  • 830523 006571 C40H001 RB SUPPORT ACTIVITY 2 HP 0.002 2.17 RB ENTRY SUPPORT - ECUIPMENT AIRLOCK
  • 830523 006571 C20H001 RB SUPPORT ACTIVITY 4 RP 0.030 7.61 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830523 006571 C20H001 RB SUPPORT ACTIVITY 2 MD 0.010 2.23 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830523 006571 C20H001 RB SUPPORT ACTIVITY 19 CN 0.117 30.13 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830523 006%75 C20H001 RB SMPPORT ACTIVITY 5 CN 0.000 39.18 OPERATE AND MAINTAIN NLB PUMP 830523 006564 C20H001 RB SUPPORT ACTIVITY 2 CN 0.263 2.08 TRASH AND EQUIPMENT REMOVAL 830527 006600 C20H001 RB SUPPORT ACTIVITY 1 AD 0.077 1.02 SAFETY INSPECTION 830527 006596 C20H001 RB SUPPORT ACTIVITY 2 CN 0.409 3.37 FIRE DETECTION SYSTEM WALKDOWN 830531 006611 C20H001 RB SUPPORT ACTIVITY 58 CN 0.028 118.67 RB ENTRY SUPPORT - ALL AREAS
  • 830531 006611 C20H001 RB SUPPORT ACTIVITY 20 HP 0.010 95.43 RB ENTRY SUPPORT - ALL ARE AS
  • 830531 006611 C20H001 RB SUPPORT ACTIVITY 2 RP 0.000 2.33 RB ENTRY SUPPORT - ALL AREAS

$830531 006611 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 3,25 RB ENTRY SUPPORT - ALL AREAS 830531 006612 C20H001 RB SUPPORT ACTIVITY 4 CN 0.020 6.27 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830531 006613 C20H001 RD SUPPORT ACTIVITY 9 CN 0.040 16.33 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830531 006632 C20H001 RB SUPPORT ACTIVITY 4 CN 0.000 30.38 OPERATE AND MAINTAIN NLB PUMP 830603 006640 C20H001 RB SUPPORT ACTIVITY 4 CN 0.287 5.33 INSTALL HANDRAIL 830606 00666 C20H001 RB SUPPORT ACTIVITY 9 CN 0.044 15.68 RB ENTRY. SUPPORT - PERSONNEL AIRLOCK e 830606 006664 C20HC01 RB SUPPORT ACTIVITY 1 CN 0.000 3.87 OPERATE AND MAINTAIN NLB PUMP d RB SUPPORT ACTIVITY 1 HP 0.000 1.00 OPERATE AND MAINTAIN NLB PUMP C3 *830606 006664 C20H001 830606 006665 C20H001 RB SUPPORT ACTIVITY 1 CN 0.003 0.67 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830606 006667 C20H001 RB SUPPORT ACTIVITY 36 CN 0.031 62.64 RB ENTRY SUPPORT - ALL AREAS y

  • 830606 006667 C20H001 RB SUPPORT ACTIVITY 19 HP 0.017 108.42 RB ENTRY SUPPORT - ALL AREAS
  • 830606 006667 C20H001 RB SUPPORT ACTIVITY 3 RP 0.000 4.43 RB ENTRY SUPPORT - ALL AREAS
  • 830606 006667 C20H001 RB SUPPORT ACTIVITY I IC 0.000 0.50 RB E NTRY SUPPORT - ALL APE AS 830608 006675 C20H001 RB SUPPORT ACTIVITY 1 OP 0.124 1.17 TRASH REMOVAL
  • 830608 006675 C20H001 RB SUPPORT ACTIVITY 1 UM 0.092 1.05 TRASH REMOVAL 830609 006681 C20H001 RB SUPPORT ACTIVITY 1 CN 0.002 1.10 TRASH REMOVAL 830609 006682 C20H001 RB SUPPORT ACTIVITY 1 CN 0.102 1.32 SAFETY AND HOUSEKEEPING INSPECTION 8830609 006682 C20H001 RB SUPPORT ACTIVITY 1 AD O.104 1.35 SAFETY AND HOUSEKEE PING INSPECTION 830610 006689 C20H001 RB SUPPORT ACTIVITY 2 CN 0.274 2.47 INSTALL LADDER EXTENSION 830610 006695 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 2.35 INSTALL PIPE HANGERS FOR PROCESS WATER 830613 006714 C20H001 RB SUPPORT ACTIVITY 6 CN 0.000 7.58 CPERATE AND MAINIAIN NLB PUMP 830613 006719 C20H001 RB SUPPORT ACTIVITY 56 CN 0.015 112.03 RB ENTRY SUPPORT - ALL AREAS
  • 830613 006719 C20H001 RB SUPPORT ACTIVITY 15 HP 0.004 69.95 RB ENTRY SUPPORT - ALL AREAS 830613 006720 C20H001 RB SUPPORT ACTIVITY 10 CN 0.078 16.08 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830614 006726 C20H001 RB SUPPORT ACTIVITY 1 CN 0.010 1.43 TRASH REMOVAL 830620 006760 C20H001 RB SUPPORT ACTIVITY 2 OP 0.268 2.22 TLD PLACEMENT - 305' ELEV INSIDE D RINGS

$830620 006760 C20H001 RB SUPPORT ACTIVITY 1 UM 0.420 1.18 TLD PLACEMENT - 305' ELEV INSIDE D RINGS 830620 006762 C20H001 RB SUPPORT ACTIVITY 14 CN 0.096 24.85 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830620 006763 C20H001 RB SUPPORT ACTIVITY 52 CN 0.017 116.42 RB ENTRY SUPPORT

  • 830620 006763 C20H001 RB SUPPORT ACTIVITY 20 HP 0.003 110.43 RB ENTRY SUPPORT
  • 830620 006763 C20H001 RB SUPPORT ACTIVITY 3 OP 0.000 1.93 RB ENTRY SUPPORT
  • 830620 006763 C20H001 RB SUPPORT ACTIVITY 1 RP 0.000 0.93 RB ENTRY SUPPORT 830620 006778 C20H001 RB SUPPORT ACTIVITY 11 CN 0.000 47.12 OPERATE AND MAINTAIN NLB PUMP
  • 830620 006778 C20H001 RB SUPPORT ACTIVITY 1 UM 0.000 0.00 OPERATE AND MAINTAIN NLB PUMP 830623 006791 C20H001 RB SUPPORT ACTIVITY I AD 0.083 1.05 SAFETY AND HOUSEKEEPING INSPECTION
  • 830623 006791 C20H001 RB SUPPORT ACTIVITY 1 CN 0.077 1.03 SAFETY AND HOUSEKEEPING INSPECTION 830627 006819 C20H001 RB SUPPORT ACTIVITY 2 CN 0.000 6.40 OPERATE AND MAINTAIN NLB PUMP

DATE 022486 PAGE 19 PNO. 18 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..................... E. N T R..... CODE.... REM... HOURS...........................CRIPTION TASK DES ........ NUMBER...................IVITY . NUMBER ACT

  • DATE
  • 830627 006819 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.43 OPERATE AND MAINTAIN NLB PUMP 830628 006826 C20H001 RB SUPPORT ACTIVITY 25 CN 0.047 42.27 RB ENTRY SUPPORT - ALL AREAS
  • 830628 006826 C20H001 RB SUPPORT ACTIVITY 10 HP 0.002 49.35 RB ENTRY SUPPORT - ALL AREAS
  • 830628 006826 C20H001 RB SUPPORT ACTIVITY 1 RP 0.002 5.07 RB ENTRY SUPPORT - ALL AREAS
  • 830628 006826 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.68 RB ENTRY SUPPORT - ALL AREAS 830628 006827 C20H001 RB SUPPORT ACTIVITY 7 CN 0.051 12.60 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830628 006828 C20H001 RB SUPPORT ACTIVITY 1 CN 0.013 4.69 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830702 006866 C20H001 RB SUPPORT ACTIVITY 5 CN 0.023 15.84 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK
  • 830702 006866 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 1.31 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830702 006867 C20H001 RB SUPPORT ACTIVITY 66 CN 0.017 167.44 RB ENTRY SUPPORT - ANTERDOM
  • 830702 006867 C20H001 RB SUPPORT ACTIVITY 14 HD 0.002 87.32 RB ENTRY SUPPORT - ANTEROOM
  • 830702 006867 C20H001 RB SUPPORT ACTIVITY 2 MM 0.000 4.47 RB ENTRY SUPPORT - ANTEROOM
  • 830702 006867 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.42 RB ENTRY SUPPORT - ANTEROOM
  • 830702 006867 C20H001 RB SUPPORT ACTIVITY

! RP 0.002 7.12 RB ENTRY SUPPORT - ANTER0OM 830702 006868 C20H001 RB SUPPORT ACTIVITY 15 CN 0.126 28.87 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830705 006875 C20H001 RB SUPPORT ACTIVITY 3 CN 0.000 14.27 OPERATE AND MAINTAIN NLB PUMP 830708 006897 C20H001 RB SUPPORT ACTIVITY 2 CN 0.220 2.70 SAFETY AND H3USEKEEPING INSPECTION 830709 006920 C20H001 RB SUPPORT ACTIVITY 16 CN 0.123 28.72 RB ENTRY SUPPORT - PERSONNEL AIRLOCK 830709 006921 C20H001 RB SUPPORT ACTIVITY 2 CN 0.020 5,40 RB ENTRY SUPPORT - EQUIPMENT AIRLOCK 830709 006922 C20H001 RB SUPPORT ACTIVITY 75 CN 0.026 155.09 RB ENTRY SUPPORT - ANTER0OM _a C3 *S30709 006922 C20H001 RB SUPPORT ACTIVITY 23 HP 0.012 115.20 RB ENTRY SUPPORT -ANTEROOM hJ *830709 006922 C20H001 RR SUPPORT ACTIVITY 1 RP 0.000 0.52 RB ENTRY SUPPORT - ANTEROOM I *830709 006922 C20H001 RB SUPPORT ACTIVITY 1 OP 0.002 1.97 RB ENTRY SUPPORT - ANTER0OM 830711 006919 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 5.60 OPERATE AND MAINTAIN NLB PUMP 830715 006964 C20H001 RB SUPPORT ACTIVITY 2 CN 0.067 1.52 PENETRATION INSPECTION 830720 007002 C20H001 RB SUPPORT. ACTIVITY 1 AD 0.138 2.18 SAFETY AND H3USEKEEPING INSPECTION

  • 830720 007002 C20H001 RB SUPPORT ACTIVITY 1 AM 0.117 2.12 SAFETY AND HOUSEKEEPING INSPECTION 830805 007133 C20H001 RB SUPPORT ACTIVITY 2 CN 0.109 1.93 CHANGE BREAKERS ON POWER BUGGY 830809 007167 C20H001 RB SUPPORT ACTIVITY 2 OP 0.228 3.43 CONTAMINATION CONTROL-RVHSS &
  • D' RINGS
  • 830809 007167 C20H001 RB SUPPORT ACTIVITY 1 UM 0.145 1.72 CONTAMINATION CONTROL-RVHSS &
  • D' RINGS
  • 830809 007167 C20H001 RB SUPPORT ACTIVITY 1 CM 0.171 1,63 CONTAMINATION CONTROL-RVHSS &
  • D' RINGS 830809 007169 C20H001 RB SUPPORT ACTIVITY 1 AM 0.167 1.48 DECON INSPECTION
  • 830809 007169 C20H001 RB SUPPORT ACTIVITY 1 CN 0.137 1.48 DECON INSPECTION 830812 007201 C20H001 RB SUPPORT ACTIVITY 1 CN 0.263 3.48 INSTALL HOSES AND MANIFOLD-347' LEVEL
  • 830812 007201 C20H001 RB SUPPORT ACTIVITY 1 OP 0.000 0.85 INSTALL HOSES AND MANIF OLD-347' LEVEL 830812 007202 C20H001 RB SUPPORT ACTIVITY 2 CN 0.421 2.77 INSTALL AIR HOSES & MANIFOLD-305
  • LEVEL 830816 007240 C20H001 RB SUPPORT ACTIVITY 4 CN 0.591 7.73 SET UP TEMPORARY STORAGE AREA-347' LEVEL
  • 830816 007240 C20H001 RB SUPPORT ACTIVITY 1 EL 0.154 2.25 SET UP TEMPORARY STORAGE AREA-347' LEVEL 830819 007264 C20H001 RB SUPPORT ACTIVITY 4 CN 0.192 4.28 SET UP TEMPORARY STORAGE AREA-347' LEVEL 830822 007296 C20H001 RB SUPPORT ACTIVITY 1 CN 0.000 0.35 OPERATE NLB PUMP 830823 007299 C20H001 RB SUPPORT ACTIVITY 2 RP 0.212 2.05 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 RW 0.047 1.18 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 UM 0.066 1.52 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 CM 0.061 1.05 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 MM 0.094 1.42 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 1 HP 0.076 0.93 CONTAMINATION CONTROL ACTIVITIES
  • 830823 007299 C20H001 RB SUPPORT ACTIVITY 2 CN 0.142 2.48 CONTAMINATION CONTROL ACTIVITIES 830826 007325 C20H001 RB SUPPORT ACTIVITY 3 CN 0.172 1.60 REPLACE FITTINGS ON AIR HEADERS 830830 007357 C20N001 RB SUPPORT ACTIVITY 3 CN 0.197 4.03 INSTALL TOOL BOX AND CASTER FRAME
  • 830830 007357 C20iO01 RB SUPPORT ACTIVITY 1 MM 0.053 1.47 INSTALL TOOL BOX AND CASTER FRAME

DATE 022486 PAGE 20 PNO. 19 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ........................ C O D E... R E.M..... H. O U R S................... E S. C. R I P T I O N ENTR TASK D

  • ....... NUMBER.NUMBE.R................IT.Y
  • DATE ACTIV 830907 007415 C20H001 RB SUPPORT ACTIVITY 3 CN 0.188....

3.25 MAINTAIN VACUUM FILTERS AND HOSES

  • 830907 007415 C20H001 RB SUPPORT ACTIVITY 1 HP 0.012 0.58 MAINTAIN VACUUM FILTERS AND HOSES 830907 007418 C20H001 RB SUPPORT ACTIVITY 4 RP 0.103 3.27 REMOVE TOPOGRAPHY EQUIPMENT 830912 007449 C20H001 RB SUPPORT ACTIVITY 2 CN 0.069 1,73 INSTALL ROLLER BEDS AND LUBRICATE 830913 007473 C20H001 R8 SUPPORT ACTIVITY 4 CN 0.439 7.73 IDENTIFY & LABEL TEMP CABLES-ELEVATOR 830920 007524 C20H001 RB SUPPORT ACTIVITY 1 AM 0.141 1.90 SAFETY & HOUSEKEEPING INSPECT OF D RINGS
  • 830920 007524 C20H001 RR SUPPORT ACTIVITY 1 CN 0.158 2.10 SAFETY & HOUSEKEEPING INSPECT OF D RINGS
  • 830920 007524 C20H001 RB SUPPORT ACTIVITY 1 RP 0.110 2.10 SAFETY & HOUSEKEEPING INSPECT OF D RINGS 830921 007533 C20H001 RB SUPPORT ACTIVITY 4 CN 0.627 6.95 IDENTIFY AND LABEL TEMPORARY CABLES 830922 007541 C20H001 RB SUPPORT ACTIVITY 1 RP 0.097 1.72 CLEAN UP SERVICE STRUCTURE
  • 830922 007541 C20H001 RB SUPPORT ACTIVITY 1 CN 0.058 1.72 CLEAN UP SERVICE STRUCTURE 830926 007562 C20HG01 RB SUPPORT ACTIVITY 2 CN 0.362 3.40 IDENTIFY AND LABEL CABLES 830930 007603 C20H001 RB SUPPORT ACTIVITY 2 CN 0.227 3.78 IDENTIFY AND LABEL CABLES 831003 007678 C20H001 RB SUPPORT ACTIVITY 2 OP 0.244 3.33 CONTAINMENT CLEANUP - ALL ELEVATIONS
  • 831003 007678 C20H001 RB SUPPORT ACTIVITY

! EL 0.112 1.6' CONTAINMENT CLEANUP - ALL ELEVATIONS

  • 831003 007678 C20H001 RB SUPPORT ACTIVITY 2 IC 0.353 3.87 CONTAINMENT CLEANUP - ALL ELEVATIONS
  • 831003 007678 C20H001 RB SUPPORT ACTIVITY 1 UM 0.174 1.78 CONTAINMENT CLEANUP - ALL ELEVATIONS
  • 831003 007678 C20H001 RB SUPPORT ACTIVITY 2 CN 0.346 3.83 CONTAINMENT CLEANUP - ALL ELEVATIONS 831018 007790 C20H001 RB SUPPORT ACTIVITY Z AD 0.119 2.17 SAFETY AND HOUSEKEEPING INSPECTION e
  • 831018 007790 C20H001 RB SUPPORT ACTIVITY 1 CN 0.120 2.13 SAFETY-AND HOUSEKEEPING INSPECTION d

831024 007807 C20H001 RB SUPPORT ACTIVITY 1 RP 0.060 1.22 GENERAL INSPECTION C3 *831024 007807 C20H001 RB SUPPORT ACTIVITY 1 CN 0.106 1.22 GENERAL INSPECTION W 831031 007!42 C20H001 RB SUPPORT ACTIVITY 1 IC 0.090 1.80 GENERAL CONTAINMENT CLEANUP

  • 831031 007842 C20H001 RB SUPPORT ACTIVITY 1 UM 0.078 1.67 GENERAL CONTAINMENT CLEANUP
  • 831031 007842 C20H001 RB SUPPORT ACTIVITY 2 CN 0.180 3.80 GENERAL CONTAINMENT CLEANUP 831121 007954 C20H001 RB SUPPORT ACTIVITY 3 CN 0.400 5.92 SAFETY AND HOUSEKEEPING INSPECTION
  • 831121 007954 C20H001 RB SUPPORT ACTIVITY 1 EL 0.039 0.58 SAFETY AND HOUSEKEEPING INSPECTION 840123 008308 C20H001 RB SUPPORT ACTIVITY 1 CN 0.052 1.20 REPLACE SAFETY SWITCH COVER-PLASMA ARC 840215 008468 C20H001 RB SUPPORT ACTIVITY 2 CN 0.475 5.85 NRC INSPECTION 840321 008671 C20H001 RB SUPPORT ACTIVITY 4 CN 0.183 5.15 MOVE STAGING AREA - 347' LEVEL 840328 008721 C20H001 RB SUPPORT ACTIVITY 3 CN 0.654 7.55 CLEAN UP CIRBBINB - 347' LEVEL 840710 009419 C20H001 RB SUPPORT ACTIVITY 1 CN 0.045 0.97 GENERAL INSPECTION - ALL ELEVATIONS 840713 009445 C20H001 RB SUPPORT ACTIVITY 2 OP 0.109 2.13 MANAGEMENT INSPECTION
  • 840713 009445 C20H001 RB SUPPORT ACTIVITY 3 CN 0.141 3.22 MANAGEMENT INSPECTION
  • 840713 009445 C20H001 RB SUPPORT ACTIVITY 1 CR 0.049 0.97 MANAGEMENT INSPECTION 840718 009485 C20H001 RB SUPPORT ACTIVITY 3 CN 0.327 7.32 NRC INSPECTION 840731 009594 C20H001 RB SUPPORT ACTIVITY 3 CN 0.315 3.97 INSPECT PROPOSED SCABBLING OPERATIONS 840828 009793 C20H001 RB SUPPORT ACTIVITY 12 CN 1.552 27.95 REMOVE TRASH AND EQUIPMENT 840905 009845 C20H001 RB SUPPORT ACTIVITY 7 CN 0.924 15.83 REMOVE 5 TON HOIST / INSTALL MAN BASKET 840913 009903 C20H001 RB SUPPORT ACTIVITY I CN 0.083 2.12 CUT UP PLENUM MISTING SYSTEM 840927 009995 C20H001 RB SUPPORT ACTIVITY 1 OP 0.061 2.15 REMOVE DECON EQUIPMENT
  • 840927 009995 C20H001 RB SUPPORT ACTIVITY 1 CN 0.082 2.20 REMOVE DECON EQUIPMENT
  • 840927 009995 C20H001 RB SUPPORT ACTIVITY 1 EL 0.095 2.13 REMOVE DECON EQUIPMENT
  • 840927 009995 C20H001 RB SUPPORT ACTIVITY 2 CM 0.142 4.03 REMOVE DECON EQUIPMENT 841005 010045 C20H001 RB SUPPORT ACTIVITY 1 RP 0.059 0.95 DECON INSPECTION-305' 347' & D RINGS 841005 010047 C20H001 RB SUPPORT ACTIVITY 1 OP 0.039 v.82 IN-CONTAINMENT OPERATIONS SURVFILLANCE 841005 010048 C20H001 RB SUPPORT ACTIVITY 3 CN 0.541 5.25 INSTALL GANTRY CRANE RAIL SHIMS 850214 010890 C20H001 RB $UPPORT ACTIVITY 2 HP 0.048 1.48 REMOVE RX HEAD MONIT. SYS. FOR CALIB.

850225 010966 C20H001 RB SUPPORT ACTIVITY 3 CN 0.255 5.73 CONTAINMENT CLEANUP 850301 011019 C20H001 RB SUPPORT ACTIVITY 3 MM 0.086 2.73 DOOR SURVEILLANCE-EQUIPMENT HATCH

~_- - - - ~ -. -.- i l l -i i DATE 022486 PAGE 21. PNO 20 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D i

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME i '

  • D. A T E... N.UMB. E R. NUMB E.R......

...........C.TIVITY................ ENTR...D. E.... E.M..... HOU. R S.............. T. A S. K D. E S.CR I P T. I O N....................... A .CO .R 350302 011020 C20H001 RB SUPPORT ACTIVITY 3 CN 0.609 5.92 CONTAINMENT CLEANUP & HOUSEKEEPING 850304 011027 C20H001 RB SUPPORT ACTIVITY 2 CN 0.239 4.67 GENERAL INSPECTION-ALL LEVELS r 850308 011076 C20H001 PB SUPPORT ACTIVITY 4 CN 0.505 7.80 CONTAINMENT CLEANUP i 850313 011118 C20H001 RB SUPPORT ACT!VITY 1 RW 0.100 0.72 INSPECT ELECTRICAL CABLES-OPEN STAIRWELL 4850313 011118 C20H001 RB SUPPORT ACTIVITY 1 CN 0.102 0.73 INSPECT ELECTRICAL CABLES-OPEN STAIRWELL 1 850313 011124 C20H001 RB SUPPORT ACTIVITY-2 CN 0.150 4.20 INSPECT POWER BUGGY FOR SAFETY 850314 011126 C20H001 RB SUPPORT ACTIVITY 1 CN 0.055 1.22 INSPECT IIF PROCESS HOSE i 850315 011137 C20H001 RB SUPPORT ACTIVITY 2 CN 0.306 5.13 CONTAINMENT CLEANUP 850315 011140 C20H001 RB SUPPORT ACTIVITY 1 OP 0.089 1.68 INSPECT 11F PROCESS FLOW PATH 850321 011187 C20H001 RB SUPPOR T ACTIVITY 2 CN 0.097 2.10 REMOVE RAIL STOP STUDS BY GRINDING f 350322 011193 C20H001 RB SUPPORT ACTIVITY 4 CN 0.245 5.52 GENERAL INSPECTION i 850325 0!!203 C20H001 RB SUPPORT ACTIVITY-4 CN 0.551 10.45 REMOVE & PLACE SHIELDING-MISSILE SHIELDS 850325 011199 C20H001 RB SUPPORT ACTIVITY 3 CN 0.234 5.50 CONT AINMENT CLE ANUP-FUEL CANAL 850326 011233 C20P001 RB SUPPORT ACTIVITY 2 CN 0.103 3.53 GEN INSPECTION-P.C. LOAD TEST AUX HOOK t 850328 011243 C20H001 RB SUPPORT ACTIVITY 2 CN 0.115 3.38 VERIF Y HOLE LAYOUT-DWCS VALV MANIFOLD i . SUBTOTAL - EXP TRCK NUMBER = C20H001 1 . PERS ENTR = 7132 ] . EXPOS REM = 77.642000 TIME HOURS 21985.580 s. 791108 980293 C20H002 RB - CCTV 5 CN 0.007 4.50 (NO TASK DESCRIPTION GIVEN) -s C3 791109 930263 C20H002 RB - CCTV 10 CN 0.005 14.33 INSTALL CAMERA & SAMPLE EQUIP-PENET 626 t 1 Jh 810203 000288 C20H002 RB - CCTV 4 OP 1.229 6.08 INSTALL CCTV EQUIP. CABLE & WORK STANDS 8 l

  • 810203 000288 C20H002 RB - CCTV 2 IC 1.465 4.62 INSTALL CCTV EQUIP. CABLE & WORK STANDS-i
  • 810203 000288 C20H002 RB - CCTV 7 UM 1.645 8.95 INSTALL CCTV EQUIP. CABLE & WORK STANDS
  • 810203 000288 C20H002 -RB - CCTV 2 EL 0.551 3.8C INSTALL CCTV EQUIP. CABLE & WORK STANDS
  • 810203 000288 C20H002 RB - CCTV 1 MM 0.263 1.33 INSTALL CCTV EQUIP. CABLE & WORK STANDS 3810203 0002 8-C20H002 RB - CCTV 3 CN 1.470 4.97 INSTALL CCTV EQUIP. CABLE & WORK STANDS
  • 810203 000288 C20H002 RB - CCTV 1 CR 0.600 2.17 INSTALL CCTV EQUIP. CABLE & WORK STANDS 1
  • 810203 000288 C20H002 RB - CCTV 1 HP 0.555 1.50 INSTALL CCTV EQUIP, CABLE & WORK STANDS

[ 810205 000326 C20H002 RB - CCTV 2 EL ' O.810 3.67 CCTV INSTALLATION AND TESTING 8810205 000326 C20H002 RB - CCTV 2 UN 0.750 2.50 CCTV INSTALLATTON AND TESTING 4

  • 810205 000326 C20H002 RB - CCTV 2 IC 1.020 4.70 CCTV INSTALLATION AND TESTING l

3810205 000326 C20H002 RB - CCTV 1 HP 0.600 2.35 CCTV INSTALLATION AND TESTING i 810714 001473 C20H002 RB - CCTV 2 CN 0.005 3.00 INSTALL CCTV CAMERA IN ANTERDOM

  • 810714 001473 C20H002 RB - CCTV 1 IC 0.000 2.00 INSTALL CCTV CAMERA IN ANTER0OM i

810723 001533 C20H002 RB - CCTV-2 IC 1.152 2.33 CCTV MAINTENANCE 810806 001632 C20H002 RB - CCTV 1 OP 0.005 4.57 REPAIR CCTV CONTROL BOX 1

  • 810806 001632 C20H002 RB - CCTV 9 IC 0.012 23.61 REPAIR CCTV CONTROL BOX 810813 001693 C20H002 RB - CCTV 7 IC 0,000 14.58 REPAIR CCTV CONTROL BOX i

810818 001744 C20H002 RB - CCTV 8 IC 0.000 12,92 REPAIR CCTV EQUIP / CALIBRATE GAGES i 810825 001801 C20H002 RB - CCTV 3 IC 0.002 6.00 - REPAIR CCTV EQUIP / CALIBRATE GAGES i 810827 001812 C20H002 RB - CCTV 2 IC 0.475 3.90 CCTV MAINT/ INSTRUMENT REMOVAL 820716 004301 C20H002 RB - CCTV 3 IC 0.000 10.42 REPAIR / MODIFY CCTV CAMERA & CONTROLS

  • 820716 004301 C20H002 RB - CCTV 1 HP 0.000 2.00 REPAIR / MODIFY CCTV CAMERA & CONTROLS t
  • 820716 004301 C20H002 RB - CCTV 1 CN 0.000 4.00 REPAIR / MODIFY CCTV CAMERA & CONTROLS

} 820830 004608 C20H002 RB - CCTV 1 IC 0.000 4.50 REPAIR TV cat 1 ERA 820909 004681 C20H002 RB - CCTV 1 IC 0.106 1.75 REPAIR CCTV CAMERA FOR 281* ELEV INSPECT i -*820909 004681 C20H002 RB - CCTV 1 HP 0.123 1.83 REPAIR CCTV CAMERA FOR 281' ELEV INSPECT 821112 005090 C20H002 RB - CCTV 2 IC 0.395 4.85 REPAIR CCTV'S-ELEV 305*. 347* & P.C. i d l 821201 005217 C20H002 RB - CCTV 1 UM 0.068 1,32 CCTV CAMERA INVENTORY I -i 1-w .-p- .n, +

DATE 022486 PAGE 22 l PNO. 21 l l .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • ...TE.... NUMBE.R. NUMB. E R.............C.TIVITY...................TR...........RE.M,...... H. O U. R S......................SCRIPTION
  • DA A

EN . CODE TASK DE

  • 821201 005217 C20H002 RB - CCTV 1 IC 0.244...

1.83 CCTV CAMERA INVE NT OR Y 821208 005268 C20H002 RB - CCTV 2 IC 0.000 0.97 REPAIRS IN PENEIRATION 507 & CCTB-1 821210 005296 C20H002 RB - CCTV 2 IC 0.545 3.78 REPAIRS IN PENETRATION 507 & CCTB-1 821214 005321 C20H002 RB - CCTV 3 CN 0.631 7.67 LAYOUT AREA TO ACCEPT GANTRY 830128 005681 C20H002 RB - CCTV 1 UM 0.049 1,32 REPLACE PAN TILT UNIT ON CAMERA 6

  • 830128 005681 C20H002 RB - CCTV 1 IC 0.046 1.33 REPLACE PAN TILT UNIT ON CAMERA 6 830209 005782 C20H002 RB - CCTV 2 CN 0.204 3.46 INSTALL FEST00N CABLE FOR P.C. CAMERA 4830209 005782 C20H002 RB - CCTV 1 MM 0.105 1.87 INSTALL FEST00N CABLE FOR P.C.

CAMERA 830211 005798 C20HG02 RB - CCTV 1 UM 0.239 3.31 MA IN T E NANC E ON P.C. TV EQUIPMENT

  • 830211 005798 C20H002 RB - CCTV 1 IC 0.140 3.52 MAINTENANCE ON P.C.

TV EQUIPMENT l

  • 830211 005798 C20H002 RB - CCTV 1 RP 0.163 3.58 MAINTENANCE ON P.C TV EQUIPMENT 830215 005838 C20H002 RB - CCTV 1 IC 0.002 1.34 DECON SUMP TV CAMERA 830223 005902 C20H002 RB - CCTV 2 IC 0.130 2.58 INSPECT / REPAIR CCTV CAMERA 6 830302 005969 C20H002 RB - CCTV 1 EL 0.074 1.57 INSTALL 110 VOLT POWER TO P.C. CCTV
  • 830302 005969 C20H002 RB - CCTV 3 CN 0.310 4.81 INSTALL 110 VOLT POWER TO P.C. CCTV 830610 006690 C20H302 RB - CCTV 1 CM 0.151 1.45 MOVE TV CAMERA - 347* ELEV TO 372' ELEV
  • 830610 006690 C20H302 RB - CCTV 3 IC 0.388 5.95 MOVE TV CAMERA - 347' ELEV 10 372' ELEV
  • 830610 006690 C20H002 R3 - CCTV 1 UM 0.124 2 13 MOVE IV CAMERA - 347' ELEV TO 372* ELEV 830616 006743 C20H002 RB - CCTV 2 IC 0.340 3.53 REPAIR TV CAMERAS 3 & 7 l

8 830720 007000 C20H002 RB - CCTV 2 IC 0.753 3.63 REPAIR TV CAMERAS 3 & 5 {j 830822 007279 C20H002 RB - CCTV 2 CN 0.632 5.53 RELOCATE TV CAMERAS 2, 3&5 1 830826 007327 C20H002 RB - CCTV 2 CN 0.136 2.18 INSTALL SCAFFOLD FOR CAMERA 1 Ln s 830826 007320 C20H002 RB - CCTV 2 CN 0.778 4.30 RELOCATE TV CAMERAS 2 & 3 830829 007356 C20H002 RB - CCTV 2 CN 0.205 3.53 RELOCATE TV CAMERAS 2 3&5 830902 007378 C20H002 RB - CCTV 2 CN 0.318 4.88 RELOCATE TV CAMERA 1 AND ANTENNA 840315 008634 C20H002 RB - CCTV 3 IC 0.495 5.60 TV CAMERA REPAIR 340718 009483 C20H002 RB - CCTV 2 IC 0.174 4.35 HEAD LIFT MONITORING SYSTEMS 2840718 009483 C20H002 RB - CCTV 10 CN 0.835 20.03 HEAD LIFT MONITORING SYSTEMS 840719 009495 C20H002 RB - CCTV 3 CN 0.146 3.87 INSTALL CAMERA MULTIPLEXER 840719 009501 C20H002 RB - CCTV 3 IC 0.249 7.03 REPAIR CAMERA FOR LIFT MONITORING 840720 00950d C20H002 RB - CCTV 2 IC 0.084 2.87 REPAIR CCTV SYSTEM 840721 009511 C20H002 RB - CCTV 3 CN 0.262 4.95 RELOCATE CAMERA 5 840913 009897 C20H002 RB - CCTV 2 IC 0.699 5.62 INSTALL RCS LEVEL MONITOR / ROUTINE MAINT

  • 840913 009897 C20H002 RB - CCTV 1 CN 0.447 2.87 INSTALL RCS LEVEL MONITOR / ROUTINE MAINT 840927 009992 C20H002 RB - CCTV 2 IC 0.226 3.42 RE-MARK RCS LEVEL / TROUBLESHOOT CAMERA 8 841017 010111 C20H002 RB - CCTV 1 IC 0.031 1.18 REPAIR CAMERA 8& 2 MULTIPLEX UNITS
  • 841017 010111 C20H002 RB - CCTV 1 CN 0.028 1.22 REPAIR CAMERA 8& 2 MULTIPLEX UNITS 841220 010519 C20H002 RB - CCTV 3 IC 0.335 4.19 TROUBLESHOOT & REPAIR CAMERA 2
  • 841220 010519 C20H002 RB - CCTV 2 CN 0.322 2.93 TROUBLESHOOT & REPAIR CAMERA 2 850116 010684 C20H002 RB - CCTV 3 IC 0.569 5.87 REPAIR CAMERA 2 850122 010728 C20H002 RB - CCTV 3 CN 0.343 3.75 RELOCATE CAMERA 2 850215 010899 C20H002 RB - CCTV 2 IC 0.082 1.72 REPAIR CAMERA 1 PAN / TILT 850304 011024 C20H002 RB - CCTV 3 CN 0.384 4.63 INSTALL NEW RCS LEVEL CAMERA ON BEAM
  • 850304 011024 C20H002 RB - CCTV 3 IC 1.197 7.62 INSTALL NEW RCS LEVEL CAMERA CN BEAM 850304 011025 C20H002 RB - CCTV 1 EL 0.110 2.85 REPAIR POWER CABLE TO CAMERA 4 i

l

  • 850304 011025 C20H002 RB - CCTV 2 IC 0.245 5.83 REPAIR POWER CABLE TO CAMERA 4 850311 011083 C20H002 RB - CCTV 3 CN 0.494 5.27 MARK LEVEL INDICATOR BOARD-RCS CAMERA 850325 O!!200 C20H002 RB - CCTV 1 CN 0.150 2.77 REPAIR POWER CABLE TO CAMERA 4 l
  • 850325 011200 C20H002 RB - CCTV 1 UM 0.098 2.70 REPAIR POWER CABLE TO CAMERA 4 4850325 011200 C20H002 RB - CCTV 1 IC 0.165 2.83 REPAIR POWER CABLE TO CAMERA 4 I

l l l

DATE 022486 PAGE 23 PNO. 22 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • ....E... NUMBER. NUMBER............TI.VITY............. ENTR........... E.... R E. M.... H O U. R S................T.ASK DESCRIPTION AC

. COD

  • DAT 850328 011240 C20H002 RB - CCTV 2 IC 0.276 2.38 REPAIR RCS LEVEL CAMERA / CHECK CONTROLS

. SUBTOTAL - ExP TRCK NUMBER . C20H002 194 PERS ENTR EXPOS REM = 28.466000 TIME HOURS = 367.45000 .821203 005234 C20H003 RB RADIO SYSTEM 2 CN 0.220 3.22 MOTOROLA RADIO BASE STATION OPERATION 830901 007380 C20H003 RB RADIO SYSTEM 3 CN 0.355 6.15 REPAIR MOTOROLA ANTENNA 2 CN 0.329 2.60 RELOCATE ANTENNA 830906 007391 C20H003 RB RADIO S.YSTEM C20H003 . SUBTOTAL - EXP TRCK NUMBER = 7 PERS ENTR EXPOS REM = 0.9040000 11.970000 TIME HOURS = .821221 005381 C20H004 RB SPIDER 2 CN 0.224 2.76 GENERAL MAINT - P.C. TROLLEY SPIDER 830906 007395 C20H004 RB SPIDER 3 CN 0.255 5.26 GENERAL MAINT - P.C. TROLLEY SPIDER 850214 010887 C20H004 RB SPIDER 3 CN 0.423 9.75 SPIDER MAINTENANCE CHECK . SUBTOTAL - EXP TRCK NUMBER . C20H004 8 PERS ENTR = EXPOS REM 0.9020000 17.770000 TIME HOURS = ,.800813 084576 C20H005 RB SUPP-OUTSIDE CTMT 7 CR 0.011 13.92 PREPARE ANTEROOM FOR RB ENTRIES C3 *800813 084576 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.000 4.00 PREPARE ANTEROOM FOR RB ENTRIES Cn 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 6 CN 0,019 9.54 DECON PERSONNEL AIRLOCK I *800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 3 CR 0.048 2.00 DECON PERSONNEL AIRLOCK

  • 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.004 2.33 DECON PERSONNEL AIRLOCK
  • 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 2 HP 0.000 1.92 DECON PERSONNEL AIRLOCK
  • 800815 0B4620 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 0.58 DECON PERSONNEL AIRLOCK
  • 800815 084620 C20H005 RB SUPP-0UTSIDE CTMT 1 ES 0.003 0.50 DECON PERSONNEL AIRLOCK 830718 006978 C20H005 RB SUPP-0UTSIDE CTMT 3 CN 0.005 4.48 OPERATE NLB PUMP 830718 006983 C20H005 RB SUPP-0UTSIDE CTMT 50 CN 0.026 99.70 ANTEROOM SUPPORT FOR RB ENTRY
  • 830718 006983 C20H005 RB SUPP-0UTSIDE CTMT 23 HP 0.015 110.85 ANTER0OM SUPPORT FOR RB ENTRY 830718 006984 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.016 1.83 EQUIPMENT AIRLOCK SUPPORT 830718 006985 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.054 15.25 PERSONNEL AIRLOCK SUPPORT 830725 007034 C20H005 RB SUPP-0UTSIDE CTMT 38 CN 0.007 90.88 ANTEROOM. DECON ROOM, EQUIPMENT HATCH

$830725 007034 C20H005 RB SUPP-0UTSIDE CTMT 12 HP 0.000 65.73 ANIER00M. DECON ROOM. EQUIPMENT HATCH 830725 007035 C20H005 RB SUPP-0UTSIDE CTMT 11 CN 0.078 20.50 PERSONNEL AIRLOCK SUPPORT 830725 007054 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.000 1.00 OPERATE NLB PUMP 830801 007099 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.004 0.82 EQUIPMENT AIRLOCK SUPPORT 830801 007100 C20H005 RB SUPP-0UTSIDE CTMT 9 CN 0.088 16.33 PERSONNEL AIRLOCK SUPPORT 830801 007101 C20H005 RB SUPP-0UTSIDE CTMT 16 CN 0.005 37.45 ANTEROOM SUPPORT

  • 830801 007101 C20H005 RB SUPP-0UTSIDE CTMT 5 HP 0.000 5.72 ANTEROOM SUPPORT 830803 007119 C20H005 RB SUPP-0UTSIDE CTMT 27 CN 0.002 70.20 ANTER0OM SUPPORT
  • 830803 007119 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.000 38.22 ANTERDOM SUPPORT
  • 830803 007119 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.005 2.13 ANTER0OM SUPPORT
  • 830803 007119 C20H005 RB SUPP-0UTSIDE CTMT 1 RP O.000 0.68 ANTEROOM AUPPORT 830808 007147 C20H005 RB SUPP-0UTSIDE CTMT 95 CN 0.083 208.62 AMTER 00M SUPPORT
  • 830808 007147 C20H005 RB SUPP-0UTSIDE CTMT 31 HP 0.010 148.16 ANTEROOM SUPPORT
  • 830808 007147 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.001 8.07 ANTEROOM SUPPORT 2830808 007147 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 1.35 ANTEROOM SUPPORT
  • 830808 007147 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.000 0,77 ANTERDOM SUPPORT 830808 007148 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.006 2.28 EQUIPMENT AIRLOCK SUPPORT

DATE 022486 PAGE 24 PNO. 20 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .E XP TRCK. PERS. DEPT. EXPOS. TIME TASK DESCRIPTION . CODE..RE.M..... HOURS..........................................................

  • ....... NUMBER. NUMBER....................IVITY ACT ENTR
  • DATE 830808 007149 C20H005 RB SUPP-0UTSIDE CTMT 21 CN 0.178 40.65 PERSONNEL AIRLOCK SUPPORT 830808 007161 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.008 13.30 OPERATE NLB PUMP 830811 007190 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.002 0.55 CHECK EQUIPMENT kN HOT SHOP 830815 007220 C20H005 PB SUPP-0UTSIDE CTMT 4 CN 0.056 8.43 EQUIPMENT AIRLOCK SUPPORT 830815 007221 C20H005 RB SUPP-0UTSIDE CTMT 66 CN 0.011 168.23 ANTEROOM SUPPOR T
  • 830815 007221 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.015 82.07 ANTEROOM SUPPORT
  • 830815 007221 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.005 3.80 ANTER0OM SUPPORT 830822 007286 C20H005 RB SUPP-0UTSIDE CTMT 52 CN 0.043 145.65 ANTER0OM SUPPORT
  • 830822 007286 C20H305 RB SUPP-0UTSIDE CTMT 15 HP 0.014 71.87 ANTEROOM SUPPORT
  • 830822 007286 C22H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 2.75 ANTER0OM SUPPORT
  • 830822 007286 C20H005 RB SUPP-0UTSIDE CTMT 3 RP 0.020 15.88 ANTEROOM SUPPORT
  • 830822 007286 C20H005 RB SUPP-OUTSIDE CTMT 4 RC 0.030 17.65 ANTEROOM SUPPORT 830822 007288 C20H005 RB SUPP-OUTSIDE CTMT 14 CN 0.130 26.67 PERSONNEL & EQUIPMENT AIRLOCK SUPPORT
  • 830822 007288 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.020 2.78 PERSONNEL & EQUIPMENT AIRLOCK SUPPORT
  • 830822 007248 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.018 2.78 PERSONNEL & EQUIPMENT AIRLOCK SUPPORT 830826 007332 C20H005 RB SUPP-OUTSIDE CTMT 1 RP 0.000 1.13 STAGE EQUIPMENT AT HATCH AIRLOCK

$830826 007332 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 1.13 STAGE EQUIPMENT AT HATCH AIRLOCK 830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 58 CN 0.024 167.28 RB ENTRY SUPPORT - ALL AREAS

  • 830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.008 89.12 RB ENTRY SUPPORT - ALL AREAS e *S30829 007340 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 4.80 RB ENTRY SUPPORT - ALL AREAS
  • 830829 007340 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 2.82 RB ENIRY SUPPORT - ALL AREAS

-d C3 *830829 007340 C20H005 RB SUPP-OUTSIDE CTMT 1 RP 0.000 1.20 RB ENTRY SUPPORT - ALL AREAS J 830829 007341 C20H005 RB SUPP-0UTSIDE CTMT 15 CN 0.122 26.02 PERSONNEL & EQUIP AIRLOCKS SUPPORT 830906 007406 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.125 35.75 PERSONNE L & EQUIP AIRLOCKS SUPPORT 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 76 CN 0.055 199.99 ANTEROOM SUPPORT

  • 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 19 HP 0.005 123.25 ANTEROOM SUPPORT
  • 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 2.18 ANTEROOM SUPPORT
  • 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.003 1.73 ANTEROOM SUPPURT
  • 830906 007407 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.000 1.08 ANTEROOM SUPPORT 830906 007413 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.008 4.00 REPAIR DAMAGED NUC INST. COVER PLATE 830909 007440 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.000 4.13 PRESSURE DECAY TEST FOR SERVICE AIR 830912 007453 C20H005 RB SUPP-0UTSIDE CTMT 18 CN 0.175 33.97 PERSONNEL & EQUIP. AIRLOCKS SUPPORT 830912 007454 C20H005 RB SUPP-0UTSIDE CTMT

$9 CN 0.037 164.40 ANTEROOM SUPPORT

  • 830912 007454 C20H005 RB SUPP-0UTSIDE CTMT 16 HP O.028 87.50 ANTER0OM SUPPORT
  • 830912 007454 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.18 ANTEROOM SUPPORT 830913 007479 C20H005 RB SUPP-OUTSIDE CTMT 36 IC 0.036 134.95 DECON E NTRY SUPPORT EQUIPMENT
  • 830913 007479 C20H005 RB SUPP-0UTSIDE CTMT 2 HP 0.000 9.12 DECON ENTRY SUPPOR T EQUIPME NT
  • 830913 007479 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.000 3.95 DECON ENTRY SUPPORT EQUIPMENT 830919 007505 C20H005 RB SUPP-0UTSIDE CTMT 94 CN 0.035 253.47 ANTERDOM SUPPORT
  • 830919 007505 C20H005 RB SUPP-0UTSIDE CTMT 22 HP 0.010 117.90 ANTEROOM SUPPORT
  • 830919 007505 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 1.00 ANTER0OM SUPPORT l
  • 830919 007505 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.005 2.25 ANTEROOM SUPPORT l

830919 007506 C20H005 RB SUPP-0UTSIDE CTMT 20 CN 0.212 38.15 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS

  • 830919 007506 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.02 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 830920 007536 C20H005 RB SUPP-0UTSIDE CTMT 2 HP 0.005 4.18 DECON & TEST CCTV EQUIPMENT
  • 830920 007536 C20H005 RB SUPP-0UTSIDE CTMT 4 IC 0.010 21.45 DECON & TEST CCTV EQUIPMENT 830926 007560 C20H005 RB SUPP-0UTSIDE CTMT 40 CN 0.013 108.84 ANTEROOM SUPPORT
  • 830926 007560 C20H005 RB SUPP-0UTSIDE CTMT 11 HP 0.020 50.82 ANTER0OM SUPPORT
  • 830926 007560 C20H005 RB SUPP-0UTSIDE CTMT 1 RW 0.005 2.12 ANTER0OM SUPPORT
  • 830926 007560 C20H005 RB SUPP-0UTSIDE CTMT 1 MD 0.005 2.10 ANTER0OM SUPPORT

. _. _ _ _ __._ _.- ~ t i P DATE 022486 PAGE 25 PNO. ~24 .THI-2 UNC-DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D . PERS. DEPT. EXPOS. TIME.

  • RWP

.RWP .EXP TRCK.

  • DAT.E... NUMB.E.R. NUMBE.R........... A.C. T. I VI T Y.....................

. E. N T. R... CODE.. R.E.M..... HOUR S................... T A S. K.D. E S.C ....... 0.000 1.12 ANTEROOM SUPPORT

  • 830326 007560 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 830926 007561 C20H005 RB SUPP-0UTSIDE CTMT 9 CN 0.086 16.58 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 830929 007607 C20H005 RB SUPP-0UTSIDE CTMT 8 IC 0.005 40.97 DECON & TEST CCTV EQUIPMENT

'831003 007688 C20H005 RB SUPP-0UTS!DE CTMT 10 CN 0.077 17.28 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831003 007689 C20H005 RB SUPP-0UTSIDE CTMT 66 CN 0.054 136.80 ANTEROOM SUPPORT-

  • 831003 007689 C20H005 RB SUPP-0UTSIDE CTMT 10 HP 0.014 57.88 ANTERDOM SUPPORT
  • 831003 007689 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 - 3.47 ANTER0OM SUPPORT
  • 831003 007689 C20H005 RB SUPP-0UTS!DE CTMT 2 RC 0.013 14.78 ANTER0OM SUPPORT 831007 007718 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.000 7.18 DECON & TEST CCTV EQUIPMENT
  • 831007 007718 C20H005' RB SUPP-0UTSIDE CTMT 1 HP 0.000 6.72 DECON & TEST CCTV EQUIPMENT
  • 831007 007718 C20H005 RB SUPP-0UTSIDE CTMT 4 IC 0.001 22.02 DECON & TEST CCTV EQUIPMENT 831010 007720 C20H005 RB SUPP-9UTSIDE CTMT 68 CN 0.022 145.39 ANTEROOM SUPPORT I
  • 831010 007720 C20H005 RB SUPP-0UTSIDE CTMT 23 HP 0.007 110.33 ANTERDOM SUPPORT 831010 007721 C20H005 RB SUPP-0UTSIDE CTMT 16 CN 0.108 27.17 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS
  • 831010 007721 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 0.33 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831017 007781 C20H005 RB SUPP-0UTSIDE CTMT 0 CN 0.024 86.24 RB ENTRY SUPPORT
  • 831017 007781 C20H005 RB SUPP-0UTSIDE CTMT 8 HP 0.000 32.08 RB ENTRY SUPPORT 3831017 007781 C20H005 RB SUPP-0UTSIDE CTMT 2 AD 0.000 0.90 RB ENTRY SUPPORT 831017 007782 C20H005 RB SUPP-OUTSIDE CTMT 5 CN 0.030 9.67 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 1 831024 007812 C20H005 RB SUPP-OUTSIDE CTMT 3 CN 0.017 4.85 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS C3 4831024 007812 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.002 0.50 RB ENTRY SUPPORT-FERSONNEL & EQUIP ARLKS C3 831024 007813 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.001 47.72 ANTEROOM SUPPORT e *831024 007813 C20H005 RB SUPP-0UTSIDE CTMT 4 HP 0.000 15.32 ANTER0OM SUPPORT 831031 007849 C20H005 RB SUPP-0UTSIDE CTMT 15 CN 0.008 45.77 TRASH REMOVAL-AIRLOCKS & ANTER0OM
  • 831031 007849 C20H005 RB SUPP-0UTSIDE CTMT 4 HP 0.004 20.02 TRASH REMOVAL-AIRLOCKS & ANTEROOM
  • 831031 007849 C20H005. RB SUPP-0UTSIDE CTMT 1 RC 0.000 2.63 TRASH REMOVAL-AIRLOCKS & ANTEROOM
  • 831031 007849 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.005 4.18 TRASH REMOVAL-AIRLOCKS & ANTEROOM 831031 007850 C20H005 RB SUPP-OUTSIDE CTMT 4 CN 0.043 7.58 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831107 007894 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.008 24.20 ANTEROOM SUPPORT

$831107 007894 C20H005 RB SUPP-0UTSIDE CTMT 6 HP 0.005 30.82 ANTER0OM SUPPORT $831107 007894 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.002 3.60 ANTEROOM SUPPORT

  • B31107 007894 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.001 6.70 ANTER0OM SUPPORT 831107 007895 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.032 7.55 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831110 007915 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.003 4.03 SUPPORT WORK AT PENETRATION 534
  • 831110 007915 C20H005. RB SUPP-0UTSIDE CTMT 1 HP 0.020 1.57 SUPPORT WORK AT PENETRATION 534 831114 007924 C20H005 RB SUPP-0UTSIDE CTMT 3 CN 0.019 5.05 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831114 007925 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.003 20.15 ANTER0OM SUPPORT
  • 831114 007925 C20H005 RB SUPP-0UTSIDE CTMT 2 HP 0.000 11.98 ANTEROOM SUPPORT
  • 831114 007925 C20H005 RB SUPP-OUTSIDE CTMT 1 RP 0.002 0.77 ANTEROOM SUPPORT

$831114 007925 C20H005 RB SUPPa0UTSIDE CTMT 2 RC 0.000 8.58 ANTEROOM SUPPORT 831114 007958 C20H005 RB SUPP-0UTSIDE CTMT. 12 CN 0.002 24.03 ANTERDOM SUPPORT $831114 007958 C20H005 RB SUPP-0UTSIDE CTMT 8 HP 0,000 '23.17 ANTEROOM SUPPORT + .*831114 007958 C20H005 -RB SUPP-0UTSIDE CTMT 2 OP 0.000 1.23 ANTEROOM SUPPORT 831121 007959 C20H005 RB SUPP-0UTSIDE CTMT 3 CN 0.021 4.83 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS L 831123 007994 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.001 13.21 RB ENTRY SUPPORT r

  • 831128 007994 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.000 7.63 RB ENTRY SUPPORT
  • 831128 007994 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 1.38 RB ENTRY SUPPORT 8831128 007994 C20H005 RB SUPP-0UTSIDE CTNT 1 RC 0.000 1.60 RB ENTRY SUPPORT 831128 007995 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.005 1.22 RB ENTRY SUPPORT 831205 008032 C20H005 RB SUPP-0UTSIDE CTNT 5 CN 0.033 7.33 RB ENTRY SUPPORT i

DATE 022486 PAGE 26 PNO. 25 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE... NUMBER. NUMBER....................IVITY............................ CODE........ HOURS.........................................................

ACT ENTR . REM TASK DESCRIPTION 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 3.27 ANTER0OM SUPPORT

  • 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.000 40.37 ANTER0OM SUPPORT

$831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.005 7.15 ANTER0OM SUPPORT

  • 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.35 ANTEROOM SUPPORT
  • 831205 008033 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 1.33 ANTEROOM SUPPORT 831211 008070 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.000 1.48 CAMERA CHECK 831212 008077 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.009 36.45 RB ENTRY SUPPORT
  • 831212 008077 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.000 16.08 RB ENTRY SUPPORT
  • 831212 008077 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.010 2.65 RB ENTRY SUPPORT 833212 008078 C20H005 RB SUPP-0UTSIDE CTMT 3 CN 0.025 5.43 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS 831212 008088 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.000 7.65 CAMERA CHECK AND CALIBRATION 831219 008126 C20H005 RB SUPP-0UTSIDE CTMT 18 CN 0.017 52.77 RB ENTRY SUPPORT
  • 831219 008126 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 7.25 RB ENTRY SUPPORT
  • 831213 008126 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 1.27 RB E NTRY SUPPORT
  • 831219 008126 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.005 1.23 RB ENTRY SUPPORT
  • 831219 008126 C20H005 RB SUPP-0UTSIDE CTMT 1-QA 0.000 0.63 RB ENTRY SUPPORT 831219 008127 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.031 7.82 RB ENTRY SUPPORT 831227 008170 C20H005 RB SUPP-0UTSIDE CTMT 11 CN 0.019 22.14 ANTER0OM SUPPORT
  • 831227 008170 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.002 3.17 ANTEROOM SUPPORT y' *831227 008171 C20H005 831227'008170 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.002 5.52 ANTER0OM SUPPORT RB SUPP-0UTSIDE CTMT 3 CN 0.020 3.72 RB ENTRY SUPPORT-PERSONNEL & EQUIP ARLKS w *840103 008193 C20H005 RB SUPP-0UTSIDE CTMT 5 CN 0.000 11.74 RB ENTRY SUPPORT-ANTEROOM e

840103 008193 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.020 17.33 RB ENTRY SUPPORT-ANTER0OM 840103 008194 C20H005 RB SUPP-OUTSIDE CTMT 2 CN 0.010 2.93 RB ENTRY SUPPORT-AIRLOCKS 840109 008227 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.005 48.57 RB ENTRY SUPPORT-ALL AREAS

  • 840109 008227 C20H005 RB SUPP-0UTSIDE CTMT 4 HP 0.000 10.40 RB ENTRY SUPPORT-ALL AREAS
  • 840109 008227 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.40 RB ENTRY SUPPORT-ALL AREAS 840109 008228 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.024 7.40 RB ENTRY SUPPORT-AIRLOCKS 840116 008271 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.035 9.67 RB ENTRY SUPPORT-AIRLOCKS 840116 008272 C20H005 RB SUPP-0UTSIDE CTMT 29 CN 0.022 88.21 RB ENTRY SUPPORT-ANTERDOM
  • 840116 008272 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 7.47 RB ENTRY SUPPORT-ANTEROOM
  • 840116 008272 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.005 3.02 RB ENTRY SUPPORT-ANTEROOM 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 22 CN 0.007 74.60 RB ENTRY SUPPORT-ANTEROOM
  • 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.005 17.88 RB ENTRY SUPPORT-ANTERDOM
  • 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.001 2.28 RB ENTRY SUPPOR T-ANTERDOM
  • 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.004 1.28 RB ENTRY SUPPORT-ANTEROOM
  • 840123 008302 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 1.57 RB ENTRY SUPPOR T-ANTEROOM 840123 008303 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.053 8.57 RB ENTRY SUPPORT-AIRLOCKS 840130 008356 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.088 19.20 RB ENTRY SUPPORT-AIRLOCKS 840130 008357 C20H005 RB SUPP-0UTSIDE CTMT 44 CN 0.011 30.52 RB F NTRY SUPPORT-ANTE R0OM
  • 840130 008357 C20H005 RB SUPP-0UTSIDE CTMT 8 HP 0.017 41.58 RB ENTRY SUPPORT-ANTEROOM
  • 840130 008357 C20H005 RB SUPP-0UTSIDE CTMT 2 RW 0.001 2.50 RB ENTRY SUPPORT-ANTER0OM 840206 008404 C20H005 RB SUPP-0UTSIDE CTMT 16 CN 0.180 31.18 RB ENTRY SUPPORT-AIRLOCKS 840206 003405 C20H005 RB SUPP-0UTSIDE CTMT 75 CN 0.043 240.66 RB ENTRY SUPPORT-ANTEROOM
  • 840206 003405 C20H005 RB SUPP-0UTSIDE CTMT 8 HP 0.006 41.93 RB ENTRY SUPPOR T-ANTE ROOM
  • 840206 008405 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.001 6.87 RB ENTRY SUPPORT-ANTEROOM
  • 840206 008405 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.000 1.32 RB ENTRY SUPPORT-ANTER0OM 840213 008443 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.095 20.42 RB ENTRY SUPPORT 840213 008444 C20H005 RB SUPP-0UTSIDE CTMT 59 CN 0.025 172.76 RB ENTRY SUPPORT
  • 840213 008444 C20H005 RB SUPP-0UTSIDE CTMT 14 HP 0.005 67.78 RB ENTRY SUPPORT

DATE 022486 PAGE 27 PNO. 26 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

_RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..ENTR............. REM.............,......,.............IPTION . CODE . HOURS TASK DESCR

  • .......hUMBE.R. NUMBER........=,.........I.VITY..........,.......
  • DATE ACT
  • 840213 008344 C2CH005 RB SUPP-0UTSIDE CTMT 1 OP 0.002.

0.88 RB ENTRY SUPPORT 840221 008496 C20H005 RB SUPP-0UTSIDE CTMT 12 CN 0.003 29.02 RB ENTRY SUPPORT

  • 840221 008496 C20H005 RB SUPP-0UTSIDE CTMT 3 HP 0.000 11.45 RB ENTRY SUPPORT
  • 840221 008496 C20H005 RB SUPP-CUTSIDE CTMT 1 OP 0.000 0.40 RB ENTRY SUPPORT 840221 008497 C20H005 RB SUPP-0UTSIDE CTMT 2 CN 0.009 2.80 RB ENTRY SUPPORT 840227 008531 C20H005 RB SUPP-0UTSIDE CTMT 20 CN L.130 35.42 RB ENTRY SUPPORT-AIRLOCKS 840227 008532 C20H005 RB SUPP-0UTSIDE CTMT 74 CN 0.026 245.27 RB ENTRY SUPPORT-ANTER0OM
  • 840227 008532 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.002 50.88 RB ENTRY SUPPORT-ANTEROOM
  • S40227 008532 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 0.38 RB ENTRY SUPPORT-ANTERCOM 840301 008547 C20H005 RB SUPP-0UTSIDE CTMT 9 CN 0.002 13.85 CORE DRILL THROUGH F HB WEST WALL 840305 008562 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.088 25.67 RB ENTRY SUPPORT-AIRLOCKS 840305 008563 C20H005 RB SUPP-0UTSIDE CTMT 55 CN 0.021 162.85 RB ENTRY SUPPORT-ANTEROOM 8840305 008563 C20H005 RB SUPP-CUTSIDE CTMT 19 HP 0.004 81.38 RB ENTRY SUPPORT-ANTEROOM
  • 840305 008563 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.001 1.02 RB ENTRY SUPPORT-ANTEROOM 840308 008593 C20H005 RB SUPP-0UTSIDE CTMT 4 CN 0.000 4.92 REMOVE INSULATION FROM SUPPLY LINE 840312 008597 C20H005 RB SUPP-0UTSIDE CTMT 18 CN 0.155 36.17 RB ENTRY SUPPORT-AIRLOCKS 840312 008598 C20H005 RB SUPP-0UTSIDE CTMT 68 CN 0.025 192.22 RB ENTRY SUPPORT-ANTER0OM
  • 840312 008598 C20H005 RB SUPP-0UTSIDE CTMT 16 HP 0.003 84.55 RB ENTRY SUPPORT-ANTEROOM
  • 840312 008598 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.85 RB ENTRY SUPPOR T-ANTE ROOM
  • 840312 008598 C20H005 RB SUPP-OUTSIDE CTMT I IC 0.000 0.85 RB ENTRY SUPPORT-ANTEROOM 840319 008642 C20H005 RB SUPP-0UTSIDE CTMT 15 CN 0.158 31.80 RB ENTRY SUPPORT-AIRLOCKS

_s 840319 008643 C20H005 RB SUPP-0UTSIDE CTMT 59 CN 0.011 156.31 RB ENTRY SUPPORT-ANTEROOM -s C3 *840319 008643 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.009 94.52 RB ENTRY SUPPORT-ANTER0OM 8

  • 840319 008643 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.000 4.12 RB ENTRY SUPPORT-ANTER0OM 840322 008683 C20H005 RB SUPP-0UTSIDE CTMT 20 CN 0.015 40.52 INSTALL CHILLED WATER PIPE 2840322 008683 C20H005 RB SUPP-OUTSIDE CTMT 1 HP 0,000 1.08 INSTALL CHILLED WATER PIPE 840326 008694 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0.101 30.20 RB ENTRY SUPPORT-AIRLOCKS 840326 008695 C20H005 RB SUPP-0UTSIDE CTMT 67 CN 0.008 204.02 RB ENTRY SUPPORT-ANTERDOM
  • 840326 008695 C20H005 RB SUPP-0UTSIDE CTMT 12 HP 0.006 52.57 RB ENTRY SUPPORT-ANTEROCM
  • 840326 008695 C20H005 PB SUPP-0UTSIDE CTMT 3 OP 0.000 3.93 RB ENTRY SUPPORT-ANTE ROOM 8840326 008595 C204005 RB SUPP-0UTSIDE CTMT 4 IC 0.000 4.30 RB ENTRY SUPPORT-ANTEROOM 8840326 008695 C20H305 RB SUPP-0UTSIDE CTMT 2 SE 0.000 1.93 RB ENTRY SUPPORT-ANTEROOM 840328 008724 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.005 17.70 INSTALL CHILLED WATER PIPE AND FORMS 840330 008737 C20H005 RB SUPP-0UTSIDE CTMT 7 IC 0.002 24.53 REPAIR AND TEST UNDERWATER LIGHT 840402 008747 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.082 21.52 RB ENTRY SUPPORT-AIRLOCKS 840402 008748 C20H005 RB SUPP-0UTSIDE CTMT 50 CN 0.007 138.85 RB ENTRY SUPPORT-ANTEROCM
  • 840402 008748 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.002 57.75 RB ENTRY SUPPDRT-ANTEROOM
  • 840402 008748 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.001 1.53 RB ENTRY SUPPORT-ANTEROCM
  • 340402 008748 C20H005 PB SUPP-0UTSIDE CTMT 1 EL 0.000 0.57 RB ENTRY SUPPORT-ANTERCOM
  • 840402 008748 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 0.60 RB ENTRY SUPPORT-ANTEROOM 840402 008754 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.001 10.92 FORM AND GPOUT PENETRATION P 6102 840403 008908 C20H005 RB SU*P-0UTSIDE CTMT 14 CN 0.058 22.60 RB ENTRY SUPPORT-AIRLOCKS 840409 008786 C20H005 RB SUPP-0UTSIDE CTMT 74 CN 0.047 209.53 RB ENTRY SUPPORT-ANTEROOM 1840409 008786 C20H005 RB SUPP-0UTSIDE CTMT 14 HP 0.005 32.92 RB E NT RY SUPPCR T-ANTE RCOM
  • 840409 008786 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.13 RB ENTRY SUPPORT-ANTERDOM 840409 008787 C20H005 RB SUPP-0UTSIDE CTMT 18 CN 0.126 29.33 RB ENTRY SUPPORT-AIRLOCKS 840416 008831 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.072 21.35 RB ENTRY SUPPORT-AIRLOCK 3 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 57 CN 0.017 122.02 RB ENTRY SUPPORT-ANTERCOM
  • 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 22 HP 0.006 110.48 RB ENTRY SUPPORT-ANTEROOM
  • 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 1.08 RB ENTRY SUPPORT-ANTER0OM

. ~._.. _.., I i l 1 1 1 DATE 022486 PAGE 28 PNO. 27 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..... CODE........ REM........ HOURS............... TASK D.E.S.CRI.PT ION...........................

  • D AT E... NUMS. E.R. NU.MB E.R...............IT.Y................. E. N T R ACTIV 3840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.000 1.07 RB ENTRY SUPPORT-ANTER0OM
  • 840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.001 0.23 RB ENTRY SUPPORT-ANTER0OM

$840416 008832 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 0.22 RB ENTRY SUPPORT-ANTERDOM 840423 008866 C20H005 RB SUPP-0UTSIDE CTMT 21 CN 0.145 36.47 RB ENIRY SUPPORT-AIRLOCKS 840423 008867 C20H005 RB SUPP-0UTSIDE CTMT 71 CN 0.029 224.11 RB ENTRY SUPPORT-ANTE ROOM

  • 840423 008867 C20H005 RB SUPP-0UTSIDE CTMT 22 HP 0.000 88.38 RB ENTRY SUPPORT-ANTEROOM g

2840423 008867 C20H005 RB SUPP-0UTSIDE CTMT 4 UP 0.007 3.30 RB ENTRY SUPPORT-#NTER00M }

  • 840423 008867 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.000 0.63 RB E NTRY SUPPOR T-ANTE ROOM 840430 008909 C20H005 RB SUPP-0UTSIDE CTMT 57 CN 0.017 129.41 RB ENTRY SUPPORT-ANTERDOM i
  • 840430 008909 C20H005 RB SUPF-0UTSIDE CTMT 13 HP 0.007 77.67 RB ENTRY SUPPORT-ANTERDOM i
  • 840430 008909 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 1.12 RB ENTRY SUPPORT-ANTEROOM 840507 008953 C20H005 RB SUPP-0UTSIDE CTMT 63 CN 0.026 185.73 RB ENTRY SUPPORT-ANTEROOM i
  • 840507 008953 C20H005 RB SUPP-0UTSIDE CTMT 8 HP 0.000 39.95 RB ENTRY SUPPORT-ANTEROOM
  • 840507 008953 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.37 RB ENTRY SUPPORT-ANTEROOM i
  • 840507 00895*4 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.000 1.38 RB ENTRY SUPPORT-ANTER0OM 840507 008954 C20H005 RB SUPP-0VTSIDE CTMT 16 CN 0.088 26.57 RB E NTR Y SUPPOR T-AIRLOCKS i

840514 009000 C20H005 RB SUPP-0UTSIDE CTMT 19 CN 0.107 35.73 RB ENTRY SUPPORT-AIRLOCKS 7 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 72 CN 0.002 180.61 RB ENTRY SUPPORT-ANTEROOM

  • 840514 009001 C20H005 RB SUPP-OUTSIDE CTMT 12 HP 0.005 85.30 RB ENTRY SUPPORT-ANTEROOM
  • 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.002 2.05 RB ENTRY SUPPORT-ANTER0OM f

-a +

  • 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 4 RC 0.000 23.72 RB ENTRY SUPPORT-ANTERDOM s

1-

  • 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 4.82 RB ENTRY SUPPORT-ANTER0OM

-d ' *840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 3 CM 0.005 4.62 RB ENTRY SUPPORT-ANTER0OM a i

  • 840514 009001 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.000 0.43 RB ENTRY SUPPORT-ANTER0OM 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 71 CN 0.037 195.95 RB ENTRY SUPPORT-ANTEROOM
  • 840521 009040 C20H005 RB SUPP-0VTSIDE CTMT 8 HP 0.009 46.78 RB ENTRY SUPPORT-ANTEROOM i

4

  • 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 1 RC 0.000 0.83 RB ENTRY SUPPORT-ANTEPOOM
  • 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 1.02 RB ENTRY SUPPORT-ANTER0OM 4
  • 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.70 RB ENTRY SUPPORT-ANTEROOM
  • 840521 009040 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.002 1.50 RB ENTRY SUPPORT-ANTEROOM 840521 009042 C20H005 RB SUPP-0UTSIDE CTMT 17 CN 0,088 31.22 RB ENTRY SUPPORT-AIRLOCKS
  • 840521 009042 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 3.53 RB ENTRY SUPPORT-AIRLOCKS 840530 009100 C20H005 RB SUPP-0UTSIDE CTMT 24 CN 0.019 48.65 RB ENTRY SUPPORT-ANTEROOM

$840530 009100 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.000 49.50 RB ENTRY SUPPORT-ANTERDOM

  • 840530 009100 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.65 RB ENTRY SUPPORT-ANTER0OM 1

840530 009101 C20H005 RB SUPP-0UTSIDE CTMT 6 CN 0.036 8.94 RB E NTRY SUPPOR T-AIR LOCKS

  • 840530 009101 C20H005 RB SUP,P-0UTSIDE CTMT 1 HP 0.000 0.08 RB ENTRY SUPPORT-AIRLOCKS i

840604 009122 C20H005 RB SUPP-0UTSIDE CTMT 90 CN 0.017 232.21 RB ENTRY SUPPORT-ANTEROOM

  • 840604 009122 C20H005 RS SUPP-0UTSIDE CTMT 22 HP 0.006 121.45 RB ENTRY SUPPORT-ANTEROOM i
  • 840604 009122 C20H005 RB SUPP-0UTSIDE CTMT 2 RC 0.000 7.57 RB E NTRY SUPPORT-ANTEROOM 840604 009123 C20H005 RB SUPP-OUTSIDE1CTMT 28 CN 0.149 49.78 RB ENTRY SUPPORT-AIRLUCKS 840605 009140 C20H005 RB SUPP-0UTSIDE.CTMT 2 CN 0.000 3.32 DRILL HOLES IN AUX WALL 840606 009145 C20H005 RB SUPP-0UTSIDE CTHT 2 OP 0.002 6,38 DRAIN RB COOLING SYSTEM TO SUMP

$840606 009145 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.002 1.27 DRAIN RB COOLING SYSTEM TO SUMP 840607 009151 C20H005 RB SUPP-0UTSIDE CTMT 35 CN 0.114 99.15 CUT EXISTING RR CHILLER LINES 840611 009171 C20H005 RB SUPP-0UTSIDE CTMT 23 CN 0.115 53,02 RB ENTRY SUPPORT-AIRLOCKS

  • 840611 009171 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 1.88 RB ENTRY SUPPORT-AIRLOCKS 840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 70 CN 0.024 239,91 RB ENTRY SUPPORT-ANTERDOM
  • 840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 13 HP 0,003 76.42 RB ENIRY SUPPORT-ANTEROOM
  • 840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 2.88 R8 ENTRY SUPPORT-ANTER0OM i

I 9 -.m. m

-- ~ -. - - - -.. - - -~ 4 DATE 022486 PAGE 29 PNO. -28 l .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • CWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME f .....DE... REM....H.OURS............. TASK DESCRI.PTION ............I.T Y....................TR ACTIV EN ,CO l

  • ... T E... NU.MB E. R. NUMB. E. R..
  • DA
  • 840611 009172 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.000 1,43 RB ENTRY SUPPORT-ANTEROOM e

840614 009201 C20H005. RB SUPP-0UTSIDE CTMT 8 CN 0.014 12.03 - WELD WELLOLETS/RUN TUBING 840618 009226 C20H005 RB SUPP-0UTSIDE CTMT 29 CN 0.186 53.85 RB ENTRY SUPPOR T-AIRLOCKS

  • 840618 609226 C20H005 RB SUPP-0UTSIDE CTMT 1 OD 0.000 0.87 RB E NTR Y SUPPOR T-AIRLOCKS i'

840618 009227 C20H005 RB SUPP-0UTSIDE CTMT 120 CN 0.052 387.05 RB ENTRY SUPPORT-ANTEROOM j

  • 840618 009227 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.002 80.50 RB ENTRY SUPPORT-ANTEROOM 840618 009242 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.030 22.55 RUN TUdING/ CLEAN AREA / REMOVE SCAFFOLD 840625 009305 C20H005.RB SUPP-0UTSIDE CTMT 154 CN 0.033 450.12 RB ENTRY SUPPORT-ANTERDOM
  • 840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 29 HP 0.028 152.55 RB ENTRY SUPPORT-ANTEROOM
  • 840625 009305 C20H005 RE SUPP-0UTSIDE CTMT 1 OP 0.000 0.63 RB ENTRY SUPPORT-ANTERDOM
  • 840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.001 1.38 RB ENTRY SUPPORT-ANTERDOM
  • 840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 0.05 RB ENTRY SUPPORT-ANTEROOM
  • 840625 009305 C20H005. RB SUPP-0UTSIDE CTMT 1 RP 0.002 1.40 RB ENTRY SUPPORT-ANTERDOM
  • 840625 009305 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.002 1.37 RB ENTRY SUPPORT-ANTER0OM
  • 840625 009305 C20H005.RB SUPP-0UTSIDE CTMT 1 RC 0.000 8.67 RB ENTRY SUPPORT-ANTEROOM 840625 009306 C20H005 RB SUPP-0UTSIDE CTHT 35 CN 0.394 70.72 RB ENTRY SUPPORT-AIRLOCKS I
  • 840625 0093C6 C20H005 RB SUPP-0UTSIDE CTMT 1 HP 0.000 0.38 RB ENTRY SUPPORT-AIRLOCKS 840702 009361 C20H005 RS SUPP-0UTSIDE CTMT 32 CN 0.269 62.07 RB ENTRY SUPPORT-AIRLOCKS l

840702 009362 C2CH005 RB SUPP-0UTSIDE CTMT 126 CN 0.064 381.10 RB ENTRY SUPPORT-ALL AREAS j

  • 840702 049362 C20H005 RB SUPP-0UTSIDE CTHT 9 HP 0.005 56.67 RB ENTRY SUPPOR T-ALL ARE AS
  • 840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.002 8.62 RB ENTRY SUPPORT-ALL AREAS a

4 _a po *840702 009362 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.000' 5.90 RB ENTRY SUPPORT-ALL AREAS a $840702 009362 C20H005-RB SUPP-0UTSIDE CTMT 1 RP 0.005 2,70 RB ENTRY SUPPORT-ALL AREAS 4

  • 840702 009362 C20H005 RB SUPP-OUTSIDE CTHT 2 OP 0.003 2.50 RB ENTRY SUPPORT-ALL AREAS 840709 009409 C20H005 RB SUPP-0UTSIDE CTHT 24 CN 0.157 42.83 RB ENTRY SUPPORT-AIRLOCKS 840709 009410 C20H005 RB SUPP 0UTSIDE CTMT 89 CN 0.050 292.47 RB ENTRY SUPPORT-ALL AREAS
  • 840709 009410 C20H005 RB SUPP-0UTSIDE CTMT 19 HP 0.009 93.G2 RB ENTRY SUPPORT-ALL AREAS
  • 840709 009410 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.003 11.52 RB ENTRY SUPPORT-ALL AREAS
  • 840709 009410 C20H005 RB SUPP-0UTSIDE CTMT 4 RP 0.006 10.03 RB ENTRY SUPPORT-ALL AREAS 4
  • 840709 009410 C20H005 RB SUPP-0UTSIDE CTHT 4 CH 0.002 11.85 RB ENTRY SUPPORT-ALL AREAS 840716 009463 C20H005 RB SUPP-0UTSIDE CTMT 241 CN 0.135 819.94 RB ENTRY SUPPORT-ANTEROOM
  • 840716 009463 C20H005 RB SUPP-0UTSIDE CTMT 37 HP 0.007 218.62 RB ENTRY SUPPORT-ANTEROOM 4
  • 840716 009463 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 0.85 RB ENTRY SUPPORT-ANTEROOM i
  • 840716 009463 C20H005 RB SUPP-0UTSIDE CTMT 4 RP 0.002 6.37 RB ENTRY SUPPORT-ANTERODM i

840716 009464 C20H005 RB SUPP-0UTSIDE CTHT 62 CN 0.408 115.70 RB E NTRY SUPPOR T-AIR LOCMS 840723 009533 C20H005 RB SUPP-0UTSIDE CTHT 177 CN 0.079 571.89 RB ENTRY SUPPORT-ANTER0OM 3840723 009533 C20H005 RB SUPP-0UTSIDE CTMT 19 HP 0,001 146.43 RB ENTRY SUPPORT-ANTEROOM

  • 840723 0095J3 C20H005 RB SUPP-0UTSIDE CTHT 1 OP 0.000 0.48 RB ENTRY SUPPORT-ANTER0OM l

4

  • 840723 009533 C20H005 RB SUPP-0UTSIDE CTMT 1 AH 0.000 0 75 RB ENTRY SUPPORT-ANTEROOM 840723 009534 C20H005 RB SUPP-0UTSIDE CTMT 55 CN 0.344 97.22 RB ENTRY SUPPORT-AIRLOCKS 840730 009580 C20H005-RB SUPP-0UTSIDE CTHT 77 CN 0.018 212.12 RB ENTRY SUPPORT-ANTER0OM
  • 840730 009580 C20H005 RB SUPP-0UTSIDE CTMT 11 HP 0.025 41.35 RB ENTRY SUPPORT-ANTEROOM
  • 840730 009580 C20H005 RB SUPP-0UTSIDE CTMT 1 CH 0.000 2.65 RB ENTRY SUPPORT-ANTEROOM 3
  • 840730 009580 C20H005 RB SUPP-0UISIDE CTMT 3 UM -

0.024 5.60 RB ENTRY SUPPORT-ANTER0OM 3840730 009580 C20H005 RB SUPP-DUTSIDE CTMT 4 OP 0.021 4.38 RB ENTRY SUPPORT-ANTER0OM 840730 009581 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.121 26.55 RB ENTRY SUPPORT-AIRLOCMS 840806 009637 C20H005 RB SUPP-0UTSIDE CTMT 19 CN 0.100 35.53 RB ENTRY SUPPORT-AIRLOCKS 840806 009639 C20H005 'RB SUPP-0UTSIDE CTMT 72 CN 0.023 191.02 RB E NTRY SUPPOR T-ANTE RDOM t

  • 840806 009639 C20H005 -RB SUPP-0UTSIDE CTHT 20 HP 0.009' 97.97 RB ENTRY SUPPORT-ANTER0OM 840813 009682 C20H005 RD SUPP-0UTSIDE CTMT 98 CN 0.023 297.58 RB ENTRY SUPPORT-ANTEROOM 4

4 ~ { -r--

Dait' 022486 PAGE - 30 -PNO. 29 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D 4

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ..ENTR.................... HOURS..............TAS.K D.ESCRIPTION . CODE. REM

  • DATE. NUMBER ACTIVITY
  • ............. Nut 1BE.R..............................

4840813 009682 C20H005 R8 SUFP-0UTSIDE CTMT 9 HP 0.004 40.50 RB ENiRY SUPPORT-ANTER0OM $840813 009682 C20H005 RB SUPP-0UTSIDE CTMT 3 CM O.004 7.33 RB ENTRY SWPOR T-ANTE R00M

  • 840813 009682 C20H005 R8 SUPP-0UTSIDE CTMT 2 OP 0.002 4.22 RB ENTRY SUPPORT-ANTEROOM
  • 840813 0096a2 C20H005 RB SUPP-0UTSIDE CTNT 1 Rt 0.001 1.22 RB ENTRY SUPPORT-ANTEROOM
  • 840813 009682 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 1.48 RB ENTRY SUPPORT-ANTEROOM 840813 009683 C20H005.RB SUPP-0U1GIDE CTMT 21 CN 0.123 38.70 R B E N13 Y SUPPORT-AIRLOCKS 840814 009701 C20H005 23 SUPP-0UTSIDE CTMT 2 CN 0.000 1.15 INSTALL 123 VOLT DUTLET IN AIRLOCK 840820 009732 C20H005 RB SODP-GUTSIDE CTMT 22 CN 0.168 43.87 RB ENTRY SUPPORT-AIRLGCKS
  • 840820 009732 C20H005' RR SUPP-0UTSIDE CTMT 1 RP 0.011 1 98 RB ENTRY SUPPORT-AIRLOCKS
  • 840820 009732 C20H005 FOJUPP-0UTSIDE CTMT 1 MM 0.020 1.92 RB ENTRY SUPPORT-AIRLOCKS 840820 009733 C20H005 R8 SUPP-0UTSIDE CTMT 98 CN 0.046 231.16 RB -ENTRY SUPPORT - ANTERDOM

$840820 009733 C20H005 RB SUPP-0UTSIDE CTAT 15 HP 0.061 81.42 RB ENTRY SUPPOR : - ANTEROOM <t840820 009733 C20H005 RB $UPP-0UTSIDE CTMT 2 MM 0.000 1:50 RB FNTRY SJPPORI-ANTEROOM 4340820 009733 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.53 Re r>lTRY SUPPORT-ANTEROOM

  • tA0820 009733 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 3,002 2.07 RB ENTRY SUPPORT-ANTERDOM
  • 840820 009733 C20H005 RB SUPP-0UTSTDE CTMT 1 RP 0.000 0.95 T' 4 ENTRY SUPPORT-ANTEROOM
  • 840820 009733 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.002 0.52 RR ENTRY SUPPOR T
  • ANTER0OM 840827 0G9789 C20H005 RB SUPP-0UTSIDE CTMT 24'CN 0.139 42.45 RB ENTRY SUPPORT-AIRLOCKS 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 110'CN 0.036 231.16 RB ENTRY SUPPORT-ANTEROOM
  1. 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 18'HP 0.002 104.02 RB ENTRY SUPPORT-ANTER0OM
  • 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 1.05 RB ENTRY SUPPORT-ANTER0OM
  • 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 0.53 RB ENTRY SUPPORT-ANTEROOM 00 *840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 0.53 RB ENTRY SUPPORT-ANTEROOM s.
  • 840827 06Q790 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 1.60 RB ENTRY SUPPORT-ANTEROCf1
  • 840827 009790 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0,000 1.53 RB ENTRY SUPPORT-ANTEROOM 840904 009831 C20H005 RB SUPP-0UTSIDE CTMT 23 CN 0.029 216.97

'RB ENTRY SUPPORT i 840904 009831 C20H005 RB SUPP-0UTSIDE CTMT 11 HP 0.002 46.53 RB ENTRY SUPPORT 840904 009332 RB SUPP-0UTSIDE CTMT 20 CN 0.146 38.72 RB ENTRY SUPPORT IN AIRLOCKS 840910 00987E;C20H005 C20H005 -RB SUPP-0UTSIDE CTHT 103 CN 0.C39 312.33 RB ENTRY' SUPPORT

  • 84L910 009876 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.000 34.43 RB ENTRY SUPPORT
  • 840910 009876 C20H005 58 SUPP-0UTSIDE CTMT 4 OP 0.000 4.85 RB ENTRY SUPPORT
  • 840916 009876 C20H005 EB SUPP-0UTSIDE CTMT 1 EL 0.001 1.33 RB ENTRY SUPPORT
  • 840910 002876 C20H005 RB SUPP-0UTSIDE CTMT 2 MM 0.001 2.73 RB ENTRY SUPPORT

$840910 009876 C20H00% RB SUPP-0UTSIDE CTMT 1 IC 0.001 1.60 RB ENTRY SUPPORT 1 CM 0.000 1.55 RB ENTRY SUPPORT 009876 C20H005'.RB SUPP-0UTSIDE CTMT

  • 840910 009877 C20H005 RB SUPP-00TSIDE CTMT 25 CN 0.171 45.53 RB ENTRY SUPPORT IN AIRLOCKS 840910 840917 009923 C70H005 RR SUPP-0UTSIDE CTMT 90 CN

.0.034 232.49 RB ENTRY SUPPORT $840917 009923 C20H305 'RB SUPP-0UTSIDE CTMT 2 EL 0.000 3.47 RB ENTRY SUPPORT

  • 840917 009923 C2CH005 - RB SUPP-0UTSIDE CTMT 15 HP 0.003 79.92 RB ENTRY SUPPORT
  • 840917 009923 C20H005 RB SUPP-0UTSIDE CTMT 5 OP 0.002 10.53 RB ENTRY SUPPORT
  • B40917 009923 C20H005 RD SUPP-0UTSIDE CTMT 1 RP 0.000 0.62 RB ENTRY SUPPORT
  • 840917 009923 C20H005 R6 SUPP-0UTSIDE CTMT 3 MM 0.000 8.15 RB !NTRY SUPPORT
  • 840917 009923 C20M005 RB SUPP-0UTSIDE C1MT 1 IC 0.004 1.70 RB ENTRY SUPPORT 840917 009924 C20H005 RB SUPP-0UTSIDE CiMT 24 CN 0.226 45.48 RB $NIRY SUPPORT IN AIRLOCKS F40924 009960 C20H005 RB SUPP-quTSIDE CTMT 62 CN 0.030 178.95 RB LNTRY SUPPORT-AlL AREAS
  • 840924 009960 C20H005 RB SUPP-0UTSIDE CTMT 5 HP 0.005 1G.03 RB ENTRY SUPPORT-ALL AREAS 2840924 009960 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1,47 2B ENTRY SUFFORT-ALL AREAS
  • 840924 009960 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.001 1.47 RB ENTRY SUPPORT-ALL AREAS 840924 009961 C20H005 RB SUPP-0UTSIDE CTMT 14 CN 0.111 26.67 RB ENTRY SUPPORT IN AIRLOCKS 841001 010025 C20H005 RB SUPP-0UTSIDE CTMT 26 HP 0.003 149 SO RB ENTRY SUPPORT-ALL AREAS t

j \\

- - -~ DATE 022486 PAGE 31 PNO. 30 .TMI-2 UNC: DDS - ACTIVITY. REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ACT ENTR . HOURS TASK DESCRIPTION ..........IVIT.Y...................... CODE...RE.M............................................................., -

  • D. A T E... NUMBE.R. NUMBE. R....

77 CN 0.040 194.55 RB ENTRY SUPPORT-ALL AREAS'

  • 841001 010025 C20H005 RB SUPP-OUTSIDE CTMT
  • 841001 010025 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 2.33 RB ENTRY SUPPORT-ALL AREAS 841001 010026 C20H005-RB SUPP-0UTSIDE CTHT 20 CN 0.177 40.10 RB ENTRY SUPPORT IN AIRLOCKS 841008 010068 C20H005 RB SUPP-0UTSIDE CTMT 43 CN 0.012 117.95 RB ENTRY SUPPORT
  • 841008 010068 C20H005 RB SUPP-0UTSIDE CTMT 12 HP 0.000 56,35 RB ENTRY SUPPORT
  • 841008 010068 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 5.43 RB ENTRY SUPPORT
  • 841008 010068 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.003 1.78 RB ENTRY SUPPORT
  • 841008 010068 C20H005. RB SUPP-0UTSIDE CTMT 1 IC 0.000 1.77 RB ENTRY SUPPORT a

841008 010069 C20H005 RB SUPP-0UTSIDE CTMT 9 CN 0.087 18.78 RB ENTRY SUPPORT IN AIRLOCKS 841017 010109 C20H005 RB SUPP-0UTSIDE CTMT 10 CN 0.077 17.57 RB ENTRY SUPPORT IN AIRLOCKS 841017 010110 C20H005 RB SUPP-0UTSIDE CTMT 9 HP 0.002 37.85 RB ENTRY SUPPORT

  • 841017 010110 C20H005 RB SUPP-0UTSIDE CTMT 37 CN 0.019 111.92 RB ENTRY SUPPORT 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.000 88.68 RB ENTRY SUPPORT-ALL AREAS
  • 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.000 3.27 RB ENTRY SUPPORT-ALL AREAS
  • 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 1 OS 0.002 1.93 RB ENTRY SUPPORT-ALL ARE AS
  • 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 127 CN 0.069 393.30 RB ENIRY SUPPORT-ALL AREAS

+

  • 841022 010139 C20H005 FB SUPP-0UTSIDE CTMT 1 UT 0.000 2.52 RB ENTRY SUPPORT-ALL AREAS
  • 841022 010139 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 1.92 RB ENTRY SUPPORT-ALL AREAS
  • 841022 010139 C20H005'.PB SUPP-0UTSIDE CTMT 1 MM 0.000 2.63 RB ENTRY SUPPORT-ALL AREAS 841022 010140 C20H005 RB SUPP-0UTSIDE CTMT 26 CN 0.206 54.02 RB ENTRY SUPPORT IN AIRLOCKS d

841029 010192 C20H005 RB SUPP-0UTSIDE CTMT 140 CN 0.061 443.91 RB ENTRY SUPPORT-ALL AREAS .s - Jh *841029 010192 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.010 105.73 RB ENTRY SUPPORT-ALL AREAS f

  • 841029 010192 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.003 1.22 RB ENTRY SUPPORT-ALL AREAS
  • 841029 010192 C20H005 RB SUPP-OUTSIDE CTMT 1 UT 0.000 2.22 RB ENTRY SUPPORT-ALL AREAS
  • 841029 010192 C20H005 RB SUPP-0UTSIDE CTHT 1 RP 0.000 2.30 RB ENTRY SUPPORT-ALL AREAS 841029 010193 C20H005 RB SUPP-0UTSIDE CTMT 36 CN 0.211 74.00 RB ENTRY SUPPORT IN AIRLOCKS 841105 010220 C20H005 RB SUPP-OUTSIDE CTMT 18 HP 0.027 84.05 RB ENTRY SUPPORT-ALL AREAS
  • 841105 010220 C20H005 RB SUPP-0UTSIDE CTMT 132 CN 0.054 408.88 RB ENTRY SUPPORT-ALL ARE AS
  • 841105 010220 C20H005 RB SUPP-0UTSIDE CTMT 5 OP 0.000 9.20 RB ENTRY SUPPORT-ALL AREAS
  • 841105 010220 C20H005 RB SUPP-0UTSIDE CTMT S RP 0.021 11.83 RB ENTRY SUPPORT-ALL AREAS
  • 841105 010220 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 0.87 RB ENTRY SUPPORT-ALL AREAS
  • 841105 010220 C20H005 RB SUPP-OUTSIDE CTMT 1 MM 0.000 2.13 RB ENTRY SUPPORT-ALL AREAS 841105 010221 C20H005 RB SUPP-0UTSIDE CTMT 32 CN 0,258 66.82 RB ENTRY SUPPORT IN AIRLOCKS 841113 010284 C20Ht05 RB SUPP-0UTSIDE CTHT 80 CN 0.028 232.42 RB ENTRY SUPPORT-ALL AREAS

.*841113 010284 C20H005 RB SUPP-0UTSIDE CIMT 25 HP 0.020 149.68 RB ENTRY SUPPORT-ALL AREAS

  • 841113 010284 C20H005. RB SUPP-0UTSIDE CTMT 2 OP 0.000 4,20 RB ENTRY SUPPORT-ALL AREAS
  • 841113 010284,C20H005 RB SUPP-0U1 SIDE CTMT 1 CM O.000 1.78 RB ENTRY SUPPORT-ALL AREAS 841113.010285 C20H005 RB SUPP-0UTSIDE CTMT 19 CN 0.191 42.53 RB ENTRY SUPPORT IN AIRLOCKS 841119 010312 C20H005 RB SUPP-0UTSIDE CTMT 4 8 CN -

0.009 140.98 RB ENTRY SUPPORT-ALL AREAS

  • 841119 010312 C20H005 RB SUPP-0UTSIDE CTMT 13 HP 0.007 81.62 RB ENTRY SUPPORT-ALL AREAS 841119 010313 C20H005.RB SUPP-0UTSIDE CTMT 1 OP 0.002 3.63 RB ENTRY SUPPORT IN AIRLOCKS

$841119 010313 C20H005 'RB SUPP-0UTSIDE CTMT 12 CN 0.107 26.57 RB ENTRY SUPPORT IN AIRLOCKS 841127 010362 C20H005 RB SUPP-0UTSIDE CTMT 23 CN 0.171 46.27 RB ENTRY SUPPORT IN AIRLOCKS 841127 010363 C20H005 RB SUPP-OUTSIDE CTMT 20 HP 0.003 87.80 RB ENTRY SUPPORT-ALL AREAS

  • 841127 010363 C20H005 RB SUPP-0UTSIDE CTMT 94 CN 0.016 270.65 RB ENTRY SUPPORT-ALL AREAS 3841127 010363 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 2.52 RB ENTRY SUPPORT-ALL AREAS

$841127 010363 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.88 RB ENTRY SUPPORT-ALL AREAS

  • 841127 010363 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 0.85 RB ENTRY SUPPORT-ALL AREAS 841204 010405 C20H005 RB SUPP-0UTSIDE CTMT 26 HP 0,032 116.60 RB ENTRY SUPPORT-ALL AREAS
  • 841204 010405 C20H005 RB SUPP-0UTSIDE CTMT 156 CN 0.108 513.07 RB ENTRY SUPPORT-ALL AREAS i

t 4 i DATE 022486 PAGE 32 l PNO. 31 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0 PERS. DEPT. EXPOS. TIME.

  • RWP

.RWP .EXP TRCK. ...E.N. T.R... CODE...R.EM..... HOURS....................T. ASK D.E.SCR I PT. I ON ......... T.I V I T. YAC........................

  • .... E... N. UMB E R.. N UMB E. R....
  • DAT 1
  • 841204 010405 C20H005 RB SUPP.0UTSIDE CTMT 4 OP

. 0.040 3.45 RB ENTRY SUPPORT-ALL AREAS

  • 841204 010405 C20H005 RB SUPP-0UTSIDE CTMT 3 RP 0.057 7 00 RB ENTRY SUPPORT-ALL AREAS
  • 841204 010405 C20H005 RB SUPP-0UTSIDE CTMT 1 UM 0.047 0.85 RB ENTRY SUPPORT-ALL AREAS '

841204 010406 C20H005 RB SuoP-0UTSIDE CTMT 37 CN 0.299 78.87 RB ENTRY SUPPORT IN AIRLOCKS 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 28 HP 0.119 111.38 RB ENTRY SUPPORT

  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 1 RW 0.020 3.95 RB ENTRY SUPPORT i
  • 841211 010453 C23H005 RB SUPP-0UTSIDE CTMT 107 CN 0.039 354.99 RB ENTRY SUPPORT
  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 5 EL 0.036 3.97 RB ENTRY SUPPORT i
  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMI 2 RP 0.070 7.10 RB ENTRY SUPPORT
  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.025 4.40 RB ENTRY SUPPORT
  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 7 MM 0.070 18.67 RB ENTRY SUPPORT

$841211 010453 C20H005 RB SUPP-0UTSIDE CTNT 3 IC 0 102 6.85 -RB ENTRY SUPPORT

  • 841211 010453 C20H005 RB SUPP-0UTSIDE CTMT 2 UM 0.025 6.12 RB ENTRY SUPPORT

'841211 010454 C20H005 RB SUPP-0UTSIDE CTMT 30 CN 0.210 58.25 RB ENTRY SUPPORT IN AIRLOCKS 841218 010509 C20H005. RB SUPP-OUTSIDE CTMT 13 HP 0.000 62.53 RB ENTRY SUPPORT $841218 010509 C20H005 RB SUPP-0UTSIDE CTMT 73 CN 0.038 248.53 RB ENTRY SUPPORT

  • 841218 010509 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.002 1.35 RB ENTRY SUPPORT
  • 841218 010509 C23H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 0.75 RB ENTRY SUPPORT
  • 841218 010509 C20H005 RB SUPP-OUTSIDE CTMT 1 RP 0.001 2.22 RB ENTRY SUPPORT
  • 841218 010509 C20H005 RS SUPP-0UTSIDE CTMT 1 UM 0.000 0.77 RB ENTRY SUPPORT 841218 010510 C20H005 RB SUPP-0UTSIDE CTMT 19 CN 0.225 44.03 RB ENTRY SUPPORT IN AIRLOCKS 841226 010550 C20H005 RB SUPP-0UTSIDE CTMT 42 CN 0.020 138.83 RB ENTRY SUPPORT-ALL AREAS

_s Ln *841226 010550 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.005 115.40 RB ENTRY SUPPORT-ALL AREAS e *841226 010550 C20H005 RB SUPP-0UTSIDE CTMT 5 OP 0.000 633.00 RB ENTRY SUPPORT-ALL AREAS .*841226 010550 C20H005..RB SUPP-0UTSIDE CTMT 1 RP 0.000 0.75 RB ENTRY SUPPORT-ALL AREAS j $841226 010550 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.000 2.77 RB ENTRY SUPPORT-ALL AREAS 841226 010551 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0.101 26.50 RB ENTRY SUPPORT IN AIRLOCKS 850102 010587 C20H005 RB SUPP-0UTSIDE CTMT 59 CN 0.006 176.68 RB ENTRY SUPPORT $850102 010587 C20H005 RB SUPP-0UTSIDE CTMT 14 HP 0.003 85.60 RB ENTRY SUPPORT

  • 850102 010587 C20H005 RB SUPP-0UTSIDE CTNT 1 MM 0.000 0.90 RB ENTRY SUPPORT 4
  • 850102.010587 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.000 0.90 RB ENTRY SUPPORT 4

850102 010588 C20H005 RB SUPP-0UTSIDE CTMT 13 CN 0,092 27.33 RB ENTRY SUPPORT IN AIRLOCKS-850109 010635 C20H005 RB SUPP-0UTSIDE CTMT 51 CN 0.021 147.45 RB ENTRY SUPPORT

  • 850109 010635 C20H005 RB SUPP-0UTSIDE CTMT 11 HP 0.004 69.72 RB ENTRY SUPPORT
  • 850109 010635 C20H005 RB SUPP-0UTSIDE CTMT 1 FN 0.005 1.18 RB ENTRY SUPPORT
  • 850109 010635 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0,005 1.20 RB ENTRY SUPPORT 850109 010636 C20H005 RB SUPP-0UTSIDE CTMT 10 CN O.069 17.97 RB ENTRY SUPPORT IN AIRLOCKS 850116 010690 C20H005 RB SUPP-0UTSIDE CTMT 10 HP 0.004 61.53 RB ENTRY SUPPORT

$850116 010690 C20H005 RB SUPP-0UTSIDE CTMT 83 CN 0.057 283.74 RB ENTRY SUPPORT l

  • 850116 010690 C20H005 -. RB SUPP OUTSIDE CTMT 1 OS 0.000 1.30 RB ENTRY SUPPORT k
  • 850116 010690 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.001 0.48 RB ENTRY SUPPORT l

8850116 010690 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.003 3,40 RB ENTRY SUPPORT 850116 010691 C20H005 RB SUPP-0UTSIDE CTMT 23 CN 0.162 40.40 RB ENTRY SUPPORT IN AIRLOCKS f 850123 010738 C20H005. RB.SUPP-0UTSIDE CTMT 5 OP 0.000 2.27 RB ENTRY SUPPORT

  • 850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 78 CN 0.025 236.96 PB ENTRY SUPPORT
  • 850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 6 HP 0.002 36.25 RB ENTRY SUPPORT
  • 850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 1 EL 0.000 1.40 RB ENTRY SUPPORT
  • 850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.001 1.58 RB ENTRY SUPPORT
  • 850123 010738 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.002 1.37 RB ENTRY SUPPORT 850123 010739 C20H005' RB SUPP-0UTSIDE CTMT 15 CN 0.099 29.25 RB ENIRY SUPPORT IN AIRLOCKS 1

j i

DATE 022486 PAGE 33 PNO. 32 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDINO DECONTAMINATION 286 D PERS. DEPT. EXPOS. TIME

  • RWP

.RWP .EXP TRCK. .................. T. I V I T. Y................E.N T R..... C. OD E.... R E.M..... HOURS.................... E. S.C R I P. T.I O N AC TASK D

  • D. A TE... NUMB E.R. NUMB E R 850130 010781 C20H005 RB SUPP-0UTSIDE CTMT 69 CN 0.016 183.58 RB ENTRY SUPPORT
  • 850130 010781 C2OH005 RB SUPP-0UTSIDE CTMT 5 OP 0.000 2.90 RB ENTRY SUPPORT
  • 850130 010781 C20H005 RB SUPP-0UTSIDE CTMT 18 HP 0.002 83.47 RB ENTRY SUPPORT
  • 850130 010781 C20H005 RB SUPP-0UTSIDE CTMT 1 SE 0.000 0.12 RB ENTRY SUPPORT 850130 010782 C20H005 RB SUPP-0UTSIDE CTNT 17 CN 0.137 32.60 RB ENTRY SUPPORT IN AIRLOCKS
  • 850130 010782 C20H005 RB SUPP-0UTSIDE CTMT 1 MM O.005 1.55 RB ENTRY SUPPORT IN AIRLOCKS
  • 850130 010782 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.005 1,55 RB ENTRY SUPPORT IN AIRLOCKS
  • 850130 010782 C20H005 RB SUPP-0UTSIDE CTMT 2 CM 0.005 1.98 RB ENTRY SUPPORT IN AIRLOCKS 850206 010833 C20H005 RB SUPP-0UTSIDE CTMT 19 CN 0.112 36.00 RB ENTRY SUPPORT IN AIRLOCKS 850203 010834 C20H005 RB SUPP-0UTSIDE CTMT 77 CN 0.015 239.22 RB ENTRY SUPPORT
  • 850206 010834 C20H005 RB SUPP-0UTSIDE CTMT 4 OP 0.006 4.33 RB ENTRY SUPPORT
  • 850206 010834 C20H005 RB SUPP-0UTSIDE CTMT 11 HP 0.008 68.83 RB ENTRY SUPPORT.
  • 850206 010834 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.000 1.08 RB ENTRY SUPPORT 850213 010880 C20H005 RB SUPP-0UTSIDE CTMT a6 CN 0.076 31.48 RB ENTRY SUPPORT IN AIRLOCKS 850213 010881 C20H005 RB SUPP-0UTSIDE CTMT 58 CN 0.035 161.53 RB ENTRY SUPPORT
  • 850213 010881 C20H005 RB SUPP-0UTSIDE CTMT 15 HP 0.004 61.52 RB ENTRY SUPPORT
  • 850213 010881 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.000 1.37 RB ENTRY SUPPORT 850215 010896 C20H005 RB SUPP-0UTSIDE CTMT 1 OP 0.065 1.73 LOAD 55 GALLON DRUMS WITH SCABBLE DUST

$850215 010896 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.058 1.78 LOAD 55 GALLON DRUMS WITH SCABBLE DUST 850218 010926 C20H005 RB SUPP-0UTSIDE CTMT 82 CN 0.030 273.05 RB ENTRY SUPPORT 8 850218 010926 C20H005 RB SUPP-0UTSIDE CTMT 16 HP 0.006 79.08 RB ENTRY SUPPORT (( *850218 010927 C20H005 RB SUPP-0UTSIDE CTMT 20 CN 0.109 41.13 RB ENTRY SUPPORT IN AIRLOCKS Ch 850225 010967 C20H005 RB SUPP-OLTSIDE CTMT 28 HP 0.007 179.30 RB ENTRY SUPPORT e *850225 010967 C20H005 RB SUPP-0UTSIDE CTMT 5 OP 0.000 7.17 RB ENTRY SUPPORT

  • 850225 010967 C20H005 RB SUPP-0UTSIDE CTMT 136 CN 0.038 414.48 RB ENTRY SUPPORT
  • 850225 010967 C20H005 RB SUPP-0UTSIDE CTMT 1 IC 0.000 0.73 RB ENTRY SUPPORT 850225 010968 C20H005 RB SUPP-0UTSIDE CTMT 15 CN 0.094 29.82 RB ENTRY SUPPORT IN AIRLOCKS 850227 010997 C20H005 RB SUPP-0UTSIDE CTMT 24 CN 0.174 47.75 RB ENTRY SUPPORT IN AIRLOCKS 850301 011015 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.018 4.40 PREPARE WOODEN BOXES FOR SHIPMENT 850304 011032 C20H005 RB SUPP-0UTSIDE CTMT 17 HP 0.010 69.00 RB ENTRY SUPPORT
  • 850304 011032 C20H005 RB SUPP-0UTSIDE CTMT 107 CN 0.053 357.98 RB FNTRY SUPPORT
  • 850304 011032 C20H005 RB SUPP-0UTSIDE CTMT 7 OP 0.004 8.53 RB ENTRY SUPPORT
  • 850304 011032 C20H005 RB SUPP-OUTSIDE CTMT 1 MM 0.000 0.67 RB ENTRY SUPPORT
  • 850304 011032 C20H005 RB SUPP-0UTSIDE CTMT 1 RP 0.002 4.45 RB ENTRY SUPPORT 850304 011033 C20H005 RB SUPP-0UTSIDE CTMT 30 CN 0.265 59.05 RB ENTRY SUPPORT IN AIRLOCKS 850311 011088 C20H005 RB SUPP-0UTSIDE CTMT 17 HP O.015 107.57 RB ENTRY SUPPORT
  • 850311 011088 C20H005 RB SUPP-0UTSIDE CTMT 133 CN 0.089 408.89 RB ENTRY SUPPORT
  • 850311 011088 C20H005 RB SUPP-0UTSIDE CTMT 2 IC 0.002 1.17 RB ENTRY SUPPORT 850311 011089 C20H005 RB SUPP-0UTSIDE CTMT 35 CN 0.236 67.88 RB ENTRY SUPPORT IN AIRLOCKS 850313 011115 C20H005 RB SUPP-0UTSIDE CTMT 3 RP 0.044 7.75 REMOVE AND RELEASE LSA BOXES
  • 850313 011115 C20H005 RB SUPP-0UTSIDE CTMT 1 CN 0.024 2.90 REMOVE AND RELEASE LSA BOXES 850318 011153 C20H005 RB SUPP-0UTSIDE CTMT 41 CN 0.344 85.27 RB ENTRY SUPPORT IN AIRLOCKS 850318 011154 C20H005 RB SUPP-0UTSIDE CTMT 138 CN 0.063 449.86 RB ENTRY SUPPORT
  • 850318 011154 C20H005 RB SUPP-0UTSIDE CTMT 3 OP 0.000 1.88 RB ENTRY SUPPORT
  • 850318 011154 C20H005 RB SUPP-0UTSIDE CTMT 23 HP 0.029 212.12 RB ENTRY SUPPORT
  • 850318 011154 C20H005 RB SUPP-0UTSIDE CTMT 2 RP 0.002 3.87 RB ENTRY SUPPORT 850321 011184 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.011 2.68 REMOVE AND RELEASE LSA BOXES
  • 850321 011184 C20H005 RB SUPP-0UTSIDE CTMT 1 CM 0.018 2.57 REMOVE AND RELEASE LSA BOXES
  • 850321 011184 C20H005 RB SUPP-OUTSIDE CTMT 2 RP 0.029 5.03 REMOVE AND RELEASE LSA BOXES
  • 850321 011184 C20H005 RB SUPP-0UTSIDE CTMT 2 OP 0.038 5.35 REMOVE AND RELEASE LSA BOXES

DATE 022486 PAGE 34 PNO. 33 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D AT E... NUMBE.R. NUMBE.R....................I V I T Y......,........ E. N T R..... C OD E.... R E M..........URS.._.............SK DESCRIPT.I.ON ACT

.HO TA .......s................ RB SUPP-0UTSIDE CTMT 35 CN 0.193 67.48. RB ENTRY SUPPORT IN AIRLOCKS 850325 011219 C20H005 850325 011220 C20H005 RB SUPP-0UTSIDE CTMT 125 CN 0.047 432.33 RB ENTRY SUPPORT

  • 850325 011220 C20H005 RB SUPP-0UTSIDE CTMT 17 HP 0.007 123.92 RB ENTRY SUPPORT
  • 850325 011220 C20H005 RB SUPP-0UTSIDE.CTMT 1 RP 0.000 0.37 RB ENIRY SUPPORT 850326 011226 C20H005 RB SUPP-OUTSIDE CTMT 1 OP 0.013 2.70 REMOVE TRASH AND MISC. SCRAP METAL
  • 850326 011226 C20H005 RB SUPP-0UTSIDE CTMT 1 MM 0.010 2.70 REMOVE TRASH AND MISC. SCRAP METAL

. SUBTOTAL - EXP TRCK NUMBER . C20H005 9671 PERS ENTR 16.553000 EXPOS REM TIME HOURS 29707.190 .830714 006953 C20H006 RB SAFETY INSPECTION 3 CN 0.343 3.90 INSTALL SAFETY DEVICES 830714 006951 C20H006 RB SAFETY INSPECTION 3 CN 0.342 4.60 NRC SAFETY INSPECTION

  • 830714 006951 C20H006 RB SAFETY INSPECTION 1 HP 0.095 1.73 NRC SAFETY INSPECTION 830726 007058 C20H006 RB SAFETY INSPECTION 1 AM 0.140 1.40 CABLE CHASE SAFETY INSPECTION 830812 007204 C20H006 RB SAFETY INSPECTION 4 CN 0.144 2.97 INSTALL HATCH COVERS 830822 007276 C20H006 RB SAFETY INSPECTION 1 AM 0.087 1.18 SAFETY INSPECTION-ALL LEVELS
  • 830822 007276 C20H006 RB SAFETY INSPECTION 1 HP 0.089 1.27 SAFETY INSPECTION-ALL LEVELS
  • 830822 007276 C20H006 RB SAFETY INSPECTION 1 CN 0.107 1.23 SAFETY INSPECTION-ALL LEVELS 830830 007355 C20H006 RB SAFETY INSPECTION 2 CN 0.264 3.45 SAFETY INSPECTION-ALL LEVELS a

831107 007881 C20H006 RC SAFETY INSPECTION 2 CN 0.130 2.53 NRC INSPECTION

  • 831107 007881 C20H006 RB SAFETY INSPECTION 1 AM 0.075 1.23 NRC INSPECTION

["

  • 831107 007881 C20H006 RB SAFETY INSPECTION 1 HP 0.070 1.45 NRC INSPECTION 840116 008263 C20H006 RB SAFETY INSPECTION 1 AM 0.075 1.37 SAFETY INSPECTION i
  • 840116 008263 C20H006 RB SAFETY INSPECTION 1 CN 0.075 1.55 SAFETY INSPECTION 840215 008466 C20H006 RB SAFETY INSPECTION 1 AM 0.057 1.40 SAFETY INSPECTION
  • 840215 008466 C20H006 RB SAFETY INSPECTION 2 CN 0.135 2.78 SAFETY INSPECTION 840312 008601 C20H006 AB SAFETY INSPECTION 1 AD 0.121 1.87 SAFETY INSPECTION
  • 840312 008601 C20H006 RB SAFETY INSPECTION 1 AM 0.163 1.85 SAFETY INSPECTION
  • 840312 008601 C20H006 RB SAFETY INSPECTION 1 CN 0.115 1.68 SAFETY INSPECTION 840416 008827 C20H006 RB SAFETY INSPECTION 2 CN 0.269 4.18 SAFETY INSPECTION
  • 840416 008827 C20H006 RB SAFETY INSPECTION 1 AM 0.154 2.17 SAFETY INSPECTION 840514 008996 C20H006 RB SAFETY INSPECTION 1 AD 0.071 1.05 SAFETY INSPECTION
  • 840514 008996 C20H006 RD SAFETY INSPECTION 1 AM 0.062 0.87 SAFETY INSPECTION
  • 840514 008996 C20H006 RB SAFETY INSPECTION 2 CN 0.206 2.47 SAFETY INSPECTION 840618 009219 C20H006 RB SAFETY INSPECTION 1 AM 0.082 1.13 SAFETY INSPECTION
  • 840618 009219 C20H006 RB SAFETY INSPECTION 1 CN 0.090 1.08 SAFETY INSPECTION
  • 840618 009219 C20H006 RB SAFETY INSPECTION 1 HP 0,077 1.15 SAFETY INSPECTION 840621 009264 C20H006 RB SAFETY INSPECTION 1 AM 0.146 1.28 ESTABLISH SAFE ACCESS - SFV-104 840716 009455 C20H006 RB SAFETY INSPECTION 1 AM 0.054 1.30 SAFETY INSPECTION
  • 840716 009455 C20H006 RB SAFETY INSPECTION 2 CN 0.126 2.53 SAFETY INSPECTION 840723 009519 C20H006 RB SAFETY INSPECTION 1 CN 0.082 1.38 INSPECT P C.

FOR COMBUSTIBLES

  • 840723 009519 C20H006 RB SAFETY INSPECTION 1 ES 0.070 1,32 INSPECT P.C.

FOR COMBUSTIBLES 840820 009730 C20H006 RB SAFETY INSPECTION 1 AD 0.145 2.65 SAFETY INSPECTION

  • 840820 009730 C20H006 RB SAFETY INSPECTION 2 CN 0.266 5.25 SAFETY INSPECTION 840904 009840 C20H006 RB SAFETY INSPECTION 3 CN 0.201 4.08 TROUBLESHOOT POWER BUGGY 840905 009841 C20H006 RB SAFETY INSPECTION 3 CN 0.269 4.97 REPAIR POWER BUGGY 840917 009918 C20H006 RB SAFETY INSPECTION 1 AM 0.100 1,43 SAFETY INSPECTION-FUEL CANAL. D RINGS
  • 840917 009918 C20H006 RB SAFETY INSPECTION 2 CN 0.186 3.07 SAFETY INSPECTION-FUEL CANAL D RINGS 841017 010115 C20H006 RB SAFETY INSPECTION 2 CN 0.192 3.97 SAFETY & HOUSEKEEPING INSPECi!ON
  • 841017 010115 C20H006 RB SAFETY INSPECTION 2 AM 0.188 3.37 SAFETY & HOUSEKEEPING INSPECTION

..m_ _._._____________._m.. I DATE 022486 PAGE 35 I PNO. 34 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. ENTR. C ODE.... R E.M.......HO.URS...............,........D. E. S.C R I P T I ON PERS, DEPT. EXPOS. TIME

  • DATE.. NUMBE.R. NUMBER.........

.......C.T.IVIT.Y........ A TASK t.... 841019 010126 C20H006 RB SAFETY INSPECTION 4 CN 0.481 9.30 INSTALL TEMPORARY HANDRAIL 841119 010311 C20H006 RB SAFETY INSPECTION 1 AM 0.070 1.53 SAFETY INSPECTION t 2841119 010311 C20H006 RB SAFETY INSPECTION 3 CN 0.187 4.17 SAFETY INSPECTION 841212 010462 C20H006 RB SAFETY INSPECTION 2 CN 0.203 3.82 SAFETY & HOUSEKEEPING WALK 0DWN 841217 010485 C20H006 RB SAFETY INSPECTION 2 AM 0.095 1.65 SAFETY & HOUSEKEEPING INSPECTION OF P.C.

  • 841217 010485 C20H006 RB SAFETY INSPECTION 1 CN 0.050 0.97 SAFE TY & HOUSEKEE PING INSPECTION OF P.C.

850116 010680 C20H006 RB SAFETY INSPFCTION 3 CN 0.259 4.79 SAFETY & HOUSEKEEPING INSPECTION

  • 850116 010680 C20H006 RB SAFETY INSPECTION 1 AM 0.072 1.68 SAFETY & HOUSEKEEPING INSPECTION 850206 010828 C20H006 RB SAFETY INSPECTION 2 CN 0.071 2.07 SAFETY & HOUSEKEEPING INSPECTION 850219 010908 C20H006 RB SAFETY INSPECTION 2 CN 0.194 3.35 SAFETY & HOUSEKEEPING INSPECTION
  • 850219 010908 C20H006 RB SAFETY INSPECTION 1 AD 0.090 1.58 SAFETY & HOUSEKEEPING INSPECTION l

850301 011014 C20H006 RB SAFETY INSPECTION 3 CN 0.297 9.10 IDENTIFY SLINGS 850319 011165 C20H006 RB SAFETY INSPECTION 3 CN 0.248 4.32 SAFETY & HOUSEKEEPING INSPECTION 850327 011232 C20H006 RB SAFETY INSPECTION 1 AD 0.080 1.88 SAFETY & HOUSEKEEPING INSPECTION 1

  • B50327 011232 C20H306 RB SAFETY INSPECTION 1 CN 0.074 2.13 SAFETY & HOUSEKEEPING INSPECTION

(

  • 850327 011232 C20H006 RB SAFETY INSPECTION 1 HP 0.100 1.87 SAFETY & HOUSEKEEPING INSPECTION 850329 011249 C20H006 RB SAFETY INSPECTION 2 AD 0.740 2.13 SAFETY & HOUSEKEEPING INSPECTION
  • 850329 011249 C20H006 RB SAFETY. INSPECTION 1 HP 0.350 1.03 SAFETY & HOUSEKEEPING INSPECTION

. SUBTOTAL - EXP TRCK' NUMBER C20H006 PERS ENTR. 95 . EXPOS REM 9.3240000 = TIME HOURS 147.51000 = '.GR AND-TO T AL - i. SUBTOTAL - EXP TRCK NUMBER = PERS ENTR. 0* - -a . EXPOS-REM 0.0000000* -d 00 TIME HOURS. 0.0000000* 4 . PERS ENTR. ~ 21526 i . SUBTOTAL - EXP TRCK NUMBER 21526 PERS ENT2 0* EXPOS REM 0.0000000* TIME HOURS - 0.0000000* i . EXPOS REM 666.18600 , SUBTOTAL - EXP TRCK NUMBER = 66.18600 FERS ENTR. 0* . EXPOS - REM 0.0000000* = 0.0000000* TIME HOURS. i. . TIME HOURS = 60822.060 . SUBTOTAL - EXP TRCK NUMBER 0822.060 PERS ENTR = 0* . EXPOS REM 0.0000000* . TIME HOURS 0.0000003* 840807 009644 C20H007 MANAGEMENT TOURS 1 RP 0.038 0.77 DECON INSPECTION - D-197 i 840808 009654 C20H007 MANAGEMENT TOURS 1 CN 0.035 0.63 DECON INSPECTION - 347' LEVEL 840810 009672 C20H007 MANAGEMENT TOURS 1 CN 0.029 0.68 DECON INSPECTION - 305' SCABBLED AREA 840815 009705 C20H007' MANAGEMENT TOURS 1 HP 0.079 1,10 MANAGEMENT INSPECTION - 305'--367' LEVELS

  • 840815 009705 C20N307 MANAGEMENT TOURS 1 VI 0.062 1.15 MANAGEMENT INSPECTION - 305'--367' LEVELS 840823 009760 C20H007 MANAGEMENT TOURS 1 CN 0.060 1.03 MANAGEMENT INSPECTION - ALL AREAS i
  • 840823 009760 C20H007 MANAGEMENT TOURS 1 CR 0.062 1.05 MANAGEMENT INSPECTION - ALL AREAS l

1 k t e i -

DATE 022486 PAGE 36 PNO. 35 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME TASK DESCRIPTION ACTIVI ENTR............... HOURS............... . CODE. REM

  • DATE. NUMBER. NUMBER
  • ..................................T.Y 2 CM 0.187 2.25 PLACE TLD'S/SCABBLING INSPECTION 840828.009796 C20H007 MANAGEMENT TOURS
  • 840828 009796 C20H007 MANAGEMENT TOURS 1 CN 0.050 1.33 PLACE TLD'S/SCABBLING INSPECTION
  • 840828 009796 C20H007 MANAGEMENT TOURS 1 ES 0.155 1.63 PLACE TLD'S/SCABBLING INSPECTION 840829 009802 C20H007 MANAGEMENT TOURS 3 CN 0.170 3.08 BOARD OF DIRECTORS TOUR
  • 840829 009802 C20H007 MANAGEMENT TOURS 1 CR 0.061 1.00 BOARD OF DIRECTORS TOUR 840907 009859 C20H007 MANAGEMENT TOURS 2 CN 0.086 1.95 TECH PLANNING TOUR & INSPECTION
  • 840907 009859 C20H007 MANAGEMENT TOURS 1 ES 0.042 1.03 TECH PLANNING TOUR & INSPECTION
  • 840907 009859 C20H007 MANAGE MENT TOURS 1 EG 0.032 1.00 TECH PLANNING TOUR & INSPECTION 840919 009946 C20H007 MANAGEME NT TOURS 1 F#4 0.198 1.57 TLD STUDY
  • 840919 009946 C20H007 MANAGEMENT TOURS 4 CN 0.492 4.65 TLD STUDY 841001 010011 C20H007 MANAGEMENT TOURS 2 CN 0.145 1.95 DECON INSPECTION
  • 841001 010011 C20H007 MANAGE ME NT TOURS 1 RP 0.067 1.03 DECON INSPECTION 841017 010117 C20H007 MANAGEMENT TOURS 2 OP 0.139 2.53 PLACE TLD STRINGS-D RINGS & LOCA DUCTS
  • 841017 010117 C20H007 MANAGEMENT TOURS 3 CN 0.255 4.07 PLACE TLD STRINGS-D RINGS & LOCA DUCTS 841115 010295 C20H007 MANAGEMENT TOURS 1 CN 0.090 1.80 DECON INSPECTION 850109 010632 C20H007 VANAGEMENT TOURS 1 ES 0.195 1.28 INSPECT PENETS/ INSTALL & RETRIEVE TLDS 850122 010730 C20H007 MANAGEMENT TOURS 2 CN 0.137 2.50 DECON INSPECTION & PHOTOGRAPHS
  • 850122 010730 C20H007 MANAGEMENT TOURS 2 RP 0.130 2.43 DECON INSPECTION & PHOTOGRAPHS 850124 010742 C20H007 MANAGEMENT TOURS 1 HP 0.157 1.42 INSTALL & RETRIEVE TLD STRINGS e
  • 850124 010742 C20H007 MANAGEMENT TOURS 2 CN 0.274 2.58 INSTALL & RETRIEVE TLD STRINGS

-" *850124 010742 C20H007 MANAGEMENT TOURS 1 UM 0.045 0.75 INSTALL & RETRIEVE TLD STRINGS 850208 010849 C20H007 MANAGEMENT TOURS 1 RP 0.031 0.85 DECON INSPECTION 7 850212 010868 C20H007 MANAGEMENT TOURS 1 CN 0.078 0.87 DECON INSPECTION 850213 010877 C20H007 MANAGEMENT TOURS 2 CN 0.337 4.97 DECCN INSPECTION . SUBTOTAL - EXP TRCK NUMBER . C20H007 46 PERS ENTR EXPOS REM . 3.9180000 TIME HOURS 54.930000 = .820909 004678 C30A001 DECON POLAR CRANE 1 CM 0.182 1.75 EQUIPMENT PROTECTION

  • 820909 004678 C30A001 DECON POLAR CRANE 3 UM 0.533 5.75 EQUIPMENT PROTECTION 820929 004804 C30A001 DECON POLAR CRANE 24 RP 2.800 49.26 LOW PRESSURE FLUSH OF POLAR CRANE
  • 820929 004804 C30A001 DECON POLAR CRANE 6 CN 0.846 14.38 LOW PRESSURE FLUSH OF POLAR CRANE
  • 820929 004804 C30A001 DECON POLAR CRANE 1 HP 0.118 2.23 LOW PRESSURE FLUSH OF POLAR CRANE 821001 004826 C30A001 DECON POLAR CRANE 2 RP 0.202 2.00 TRASH REMOVAL 821008 004865 C30A001 DECON POLAR CRANE 12 CN 1.518 26.63 POLAR CRANE DECON - GENERAL
  • 821008 004865 C30A001 DECON POLAR CRANE 12 RP 1.244 26.32 POLAR CRANE DECON - GENERAL
  • 821008 004865 C30A001 DECON POLAR CRANE 7 HP 0.773 15.90 POLAR CRANE DECON - GENERAL 821015 004916 C30A001 DECON. POLAR CRANE 25 CN 3.972 55.95 POLAR CRANE DECON - GENERAL
  • 821015 004916 C30A001 DECON POLAR CRANE 3 RP O.314 6.48 POLAR CRANE DECON - GENERAL
  • 821015 004916 C30A001 DECON POLAR CRANE 9 HP 1.135 22.12 POLAR CRANE DECON - GENERAL
  • 821015 004916 C30A001 DECON POLAR CRANE 1 EL 0.108 2.40 POLAR CRANE DECON - GENERAL
  • 821015 004916 C30A001 DECON POLAR CRANE 2 MM 0.224 4.12 POLAR CRANE DECON - GENERAL 821028 004998 C30A001 DECON POLAR CRANE 3 CN 0.998 11.75 POLAR CRANE DECON - GENERAL
  • 821028 004998 C30A001 DECON POLAR CRANE 1 RP 0.240 4.07 POLAR CRANE DECON - GENERAL 821105 005050 C30A001 DECON POLAR CRANE 3 CN 0.347 6.15 REMOVE EQUIPMENT PROTECTION 840206 008399 C30A001 DECON POLAR CRANE 4 CN 0.417 8.53 PREPARE P.C FOR LOAD TEST 841004 010041 C30A001 DECON POLAR CRANE 12 OP 1.418 27.78 DECON POLAR CRANE
  • 841004 010041 C30A001 DECON POLAR CRANE 2 RP 0.162 4.20 DECON POLAR CRANE
  • 841004 010041 C30A001 DECON POLAR CRANE 3 EL 0.343 6.73 DECON POLAR CRANE 3841004 010041 C30A001 DECON POLAR CRANE 6 UM 0.676 13.63 DECON POLAR CRANE

--.__m , _. _ _ - ~ _. _ _ ..s J f i - DATE 022486 PAGE 37 PNO. 36 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

,RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ACTIV ENTR TASK DESCRIPTION ................IT.Y...................... C. OD E.... R E.M....... HOURS...........4.........................................

  • D. A T E... NUMB. E R. N U.MB E. R
  • 841004 010041 C30A001 DECON POLAR CRANE 4 MM 0.472 9.65 DECON POLAR CRANE

$841004 010041 C30A001 DECON POLAR CRANE 2 CH 0.184 4.63 DECON POLAR CRANE 841115 010298 C30A001 DECON POLAR CRANE 2 OP 0.185 3.00 HANDS ON DECON OF POLAR CRANE

  • 841115 010298 C30A001 DECON POLAR CRANE 1 UM 0.063 1,48 HANDS ON DECON OF POLAR CRANE
  • 841115 010298 C30A001 DECON POLAR CRANE 1 CN 0.074 1.52 HANDS ON DECON OF POLAR CRANE

, SUBTOTAL - EXP TRCK NUMBER C30A001 PERS ENTR. 152 EXPOS REM . 18.648000 TIME HOURS 338.41000 , 820917 004721 C30C001 RB DECON-305' ELEV 4 CN 0.720 5.83 EQUIPMENT PROTECTION - 305' LEVEL 821006 004856 C30C001 RB DECON-305' ELEV 13 CN 1.447 20.48 REMOTE DECON & TOOL INVENTORY 821209 005282 C30C001 RB DECON-305' ELEV 4 OP 0.603 6.02 DECON 305' LEVEL TO 347' LEVEL

  • 821209 005282 C30C001 RB DECON-305* ELEV 2 HP 0.220 2.83 DECON 305' LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' ELEV 4 CM 0.464 6.53 DECON 305' LEVEL TO 347' LEVEL i'

-*821209 005282 C30C001 RB DECON-305* ELEV 3 UM 0.137 3.27 DECON 305' LEVEL TO 347' LEVEL

  • 821209 005282 C30C001 RB DECON-305' ELEV 1 MM 0.100 1.80 DECON 305' LEVEL TO 347' LEVEL
  • 821209 005282 C30C001 RB DECON-305' ELEV 1 IC 0.193 1.75 DECON 305' LEVEL TO 347* LEVEL o
  • 821209 005282 C30C001 RB DECON-305' ELEV 2 RP 0.380 2.77 DECON 305' LEVEL TO 347' LEVEL 4
  • 821209 005282 C30C001 RB DECON-305' ELEV 2 CN 0.220 2.17 DECON 305* LEVEL TO 347' LEVEL

= 821214 005319 C30C001 RB DECON-305' ELEV 1 RP 0.244 1.30 DECON 305' LEVEL TO 347' LEVEL

  • 821214 005319 C30C001 RB DECON-305* ELEV 1 MM 0.212 1.49 DECON 305' LEVEL TO 347' LEVEL I

d

  • 821214 005319 C30C001 RB DECON-305* ELEV 2 CH 0.404 2.75 DECON 305' LEVEL TO 347' LEVEL i

DJ 821223 005393 C30C001 RB DECON-305' ELEV 3 CN 0.383 5.83 INSTALL WATER DIST. HEADER & PUMP C3 830114 005570 C30C001. RB DECON-305' ELEV 2 CN 0.247 4.07 INSTALL PROCESS WATER HEADER & PUMP 9 330310 006019 C30C001 >RB DECON-305' ELEV 2 OP 0.000 1.87 OVERHEAD FLUSH - 305' TO 347' LEVELS 2830310 006019 C30C001 RB DECON-305 LELEV 3 UM 0.483 5.18 OVERHEAD FLUSH - 305' TO 347' LEVELS

  • 830310 006019 C30C001 RB DECON-305* ELEV' 1 EL 0.180 1.65 DVERHEAD FLUSH - 305' TO 347' LEVELS
  • 830310 006019 C30C001 RB DECON-305' ELEV 3 MM 0.382 3.55 OVERHEAD FLUSH - 305* TO 347' LEVELS
  • 830310 006019 C30C001 RB DECON-305' ELEV 1 CH 0.126 1.78 OVERHEAD FLUSH - 305' TO 347' LEVELS l'

830314 006035 C30C001 RB DECON-305' ELEV 4 CN 1.541 8.05 DECON 305' LEVEL 830603 006639 C30C001 RB DECON-305' ELEV 1 EL 0.040 0.65 FLUSH STAIRWELL - 347' & 305* LEVELS 3830603 006639 C30C001 RB DECON-305' ELEV 1 OP O.015 0.77 FLUSH STAIRWELL - 347' & 305* LEVELS

  • 830603 006639 C30C001 RB DECON-305' ELEV 1 IC 0.050 0.65 FLUSH STAIRWELL - 347' & 305' LEVELS i

830617 006750 C30C001 RB DECON-305' ELEV 1 MM 0.015 0.98 PREPARE AREA & EQUIP - 305' LEVEL 3830617 006750 C30C001 RB DECON-305' ELEV 1 UM 0.090 1.05 PREPARE AREA & EQUIP - 305' LEVEL 830620 006757 C30C001 RB DECON-305' ELEV 1 IC 0.059 1.67 FLUSH STAIRWELL - 305' & 347' LEVELS

  • 830620 006757 C30C001 RB DECON-305' ELEV 2 UM 0.089 2.15 FLUSH STAIRWELL - 305' & 347' LEVELS 305* & 347'. LEVELS f
  • 830620 006757 C30C001 RB DECON-305
  • ELEV 2 MM 0.092 2.10 FLUSH STAIRWELL -

$830620 006757 C30C001 RB DECON-305' ELEV 1 OP 0.101 1.57 FLUSH STAIRWELL - 305' & 347* LEVELS 830622 006783 C30C001 RB DECON-305' ELEV 1 IC 0.025 0.87 STAIRWELL FLUSH

  • 830622 006783 C30C001 RB DECON-305' ELEV 1 OP 0.070 0.88 STAIRWELL FLUSH
  • 830622 006783 C30C001 RB DECON-305' ELEV 1 UM 0.061 1,58 STAIRWELL FLUSH
  • 830622 006783 C30C001 RB DECON-305' ELEV 1 MM e.051 1.58 STAIRWELL FLUSH i

830628 006823 C30C001 RB DECON-305' ELEV 4 CN A.321 8.03 DECON LOCA DUCTS - P.C. & 347' LEVEL

  • 830628 006823 C30C001 RB DECON-305' ELEV 1 MM 0.104 1.72 DECON LOCA DUCTS - P.C. & 347' LEVEL 3830628 006823 C30C001 RB DECON-305' ELEV 1 EL 0.108 2.30 DECON LOCA DUCTS - P.C. & 347' LEVEL 841220 010522 C30C001 RB DECON-305* ELEV 18 CN -

3.919 35.35 RELOCATE MATERIAL / SUPPORT SCABBLING 841227 010559 C30C001 RB DECON-305' ELEV 4 CN 0.327 3.42 SCABBLE/ WET VAC/ PAINT FLOOR-305* LEVEL 850103 010596 C30C001 RB DECON-305' ELEV 2 CN 0.143 1.30 PAINT FLOOR AREA-ZONE 2 305' LEVEL 850104 010602 C30C001 RB DECON-305' ELEV 4 CN 0.608 5.13 RELOCATE MAT'L FOR SCABBLING-ZONE 3 TO 2 4 6 4

DATE 022486 PAGE 38 PNO. 37 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR CUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ........ HOURS................................T. ION TASK DESCRIP 3....... NUMBER. NUMBER.............................................. CODE........ REM ENTR

  • DATE ACTIVITY 850107 010608 C30C001 RB DECON-305' ELEV 16 CN 3.305 27.63 SCABBLE/ WET & DRY VAC/ PAINT ZONE 3 850205 010818 C30C001 RB DECON-305' ELEV 4 CN 0.441 5.22 MOVE EQUIPMENT TO SUPPORT SCABBLING 850208 010840 C30C001 RB DECON-305' ELEV 2 CN 0.138 2.78 REMOVE DECON EQUIPMENT FROM RB 850328 011241 C30C001 RB DECON-305' ELEV 3 CN 0.200 4.53 SCRUB & WET VAC FLOOR USING TRIT 0N 100

. SUBTOTAL - EXP TRCK NUMBER

C30C001 PERS ENTR

133 EXPOS REM . 19.058000 TIME HOURS 204.88000 = .820622 004123 C30D001 RB DECON-282' ELEV 1 CR 0.224 2.50 REMOTE DECON OF WALLS ON 282' LEVEL

  • 820622 004123 C300001 RB DECON-282* ELEV 10 CN 1.648 19.58 REMOTE DECON OF WALLS ON 282' LEVEL 820712 004266 C30D001 RB DECON-282
  • E LEV 2 CN 0.080 2.17 REMOTE FLUSH - 282' LEVEL 820727 004378 C30D001 RB DECON-282
  • ELEV 4 CN 0.229 9.58 REMOTE DECON - 282* LEVEL 820817 004519 C300001 RB DECON-282' ELEV 3 CN 0.194 6.17 REMOTE DECON - 282* LEVEL 820819 004537 C30D001 RB DFCON-282* ELEV 8 CN 0.335 10 12 REMOTE DECON - 282' LEVEL 820826 004584 C300001 RB DECON-282' ELEV 6 CN 0.034 10.90 REMOTE DECON - 282' LEVEL 820903 004643 C30D001 RB DECON-282' ELEV 3 CN 0.144 4.38 REMOTE DECON - 282* LEVEL 820907 004657 C300001 RB DECON-282* ELEV 4 CN 0.264 5.68 REMOTE DECON - 282' LEVEL 820915 004709 C300001 RB DECON-282' ELEV 4 CN 0.477 2.87 REMOTE DECON - 282' LEVEL 821014 004906 C30D001 RB DECON-282' ELEV 5 CN 0.422 10.83 REMOTE DECON - 282' LEVEL I

821025 004969 C300001 RB DECON-282* ELEV 1 HP 0.073 0.55 RADIATION SURVEY /TLD PLACEMENT 821027 004991 C30D001 RB DECON-282' ELEV 5 CN 0.256 9.22 REMOTE FLUSH - 282' LEVEL -d N 821103 005035 C300001 RB DECON-282* ELEV 3 CN 0.219 6.58 REMOTE DECON - 282' LEVEL "f 821115 005102 C30D001 RB DECON-282' ELEV 3 CN 0.205 4.75 REMOTE DECON - 282' LEVEL 821213 005304 C30D001 RB DECON-282' ELEV 5 CN 0.411 8.62 REMOTE DECON - 282* LEVEL 821216 005341 C30D001 RB DECON-282' ELEV 4 CM 0.244 5.47 REMOTE DECON - 282' LEVEL 821222 005387 C30D001 RB DECON-282' ELEV 1 EL 0.056 2.22 REMOTE DECON - 282' & 347' ELEVTR SHAFT

  • 821222 005387 C30D001 RB DECON-282* ELEV 3 CM 0.244 4.64 REMOTE DECON - 282' & 347' ELEVTR SHAFT
  • 821222 005387 C30D001 RB DECON-282' ELEV 1 UM 0.212 1.97 REMOTE DECON - 282* & 347' ELEVTR SHAFT 821228 005421 C30D001 RB DECON-282' ELEV 1 EL 0.053 1,77 REMOTE DECON OF 282' LEVEL
  • 821228 005421 C300001 RB DECON-282* ELEV 1 CM 0.032 2.22 REMOTE DECON OF 282' LEVEL 821229 005427 C30D001 RB DECON-282* ELEV 2 CM 0,179 4.03 REMOTE DECON OF 282' LEVEL 821230 005443 C30D001 RB DECON-282* ELEV 1 EL 0.024 1.70 REMOTE DECON OF 282* LEVEL
  • 821230 005443 C300001 RB DECON-282* ELEV 1 CM 0.045 1.75 REMOTE DECON OF 282* LEVEL 830104 005457 C30D001 RB DECON-282* ELEV 2 CN 0.185 4.80 REMOTE DECON OF 282' LE /E L 830224 005914 C30D001 RB DECON-282* ELEV 2 CN 0.383 1.83 OPEN ELEVATOR DOORS ON 305' LEVEL 830224 005916 C30D001 RB DECON-282' ELEV 2 OP 0.351 2.47 FLUSH

'D' RINGS & LINER PLATE WALLS

  • 830224 005916 C30D001 RB DECON-282' ELEV 1 UM 0.220 1.65 FLUSH

'D' RINGS & LINER PLATE WALLS

  • S30224 005916 C30D001 RB DECON-282* ELEV 1 CM 0.039 1.33 FLUSH

'D' RINGS & LINER PLATE WALLS 830315 006055 C30D001 RB DECON-282* ELEV 2 CN 0.250 2.82 REMOTE DECON/ TOOL INVENTORY - 282* LEVEL 830701 006849 C30D001 RB DECON-282* ELEV 3 C1 0.284 5.23 DECON AIR COOLERS

  • 830701 006849 C30D001 RB DECON-282' ELEV 1 UM 0.107 1.62 DECON AIR COOLERS
  • 830701 006849 C300001 RB DECON-282* ELEV 1 RP 0.080 1.78 DECON AIR COOLERS
  • 830701 006849 C30D001 RB DECON-282* ELEV 1 CN 0.085 1.77 DECON AIR COOLERS 830714 006950 C30D001 RB DECON-282* ELEV 1 CM 0.102 1.97 FLUSH 282* LEVEL WALLS VI A SEISMIC GAP
  • 830714 006950 C30D001 RB DECON-282' ELEV 1 MM 0.121 2.02 FLUSH 282* LEVEL WALLS VIA SEISMIC GAP
  • 830714 006950 C300001 RB DECON-282' ELEV 1 EL 0.130 1.97 FLUSH 282' LEVEL WALLS VIA SEISMIC GAP
  • 830714 006950 C30D001 RB DECON-282' E LEV 1 CN 0.100 2.03 FLUSH 282* LEVEL WALLS VIA SEISMIC GAP 830811 007185 C300001 RB DECON-282' ELEV 2 OP 0.179 3.12 FLUSH CORE INSTRUMENT AREA
  • 830811 007185 C300001 RB DECON-282* ELEV 1 UM 0.090 1.70 FLUSH CORE INSTRUMENT AREA
  • 830811 007185 C30D001 RS DECON-282* ELEV 2 CM 0.125 2.60 FLUSH CORE INSTRUMENT AREA

DATE 022486 PAGE 39 PNO. 38 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE AC

. ENTR . HOURS. TASK DESCRIPTION s....... NUMBER. NUMBER................... T. I. V I T Y........ ........ CODE. REM.............................................................

  • 830811 007185 C300001 RB DECON-282* ELEV 2 IC 0.201.

3.50 FLUSH CORE INSTRUMENT AREA $830811 007185 C30D001 RB DECON-282' ELEV 2 MM 0.142 3.10 FLUSH CORE INSTRUMENT AREA 831005 007703 C30D001 RB DECON-282' ELEV 3 OP 0.278 2.88 PUMP & FLUSH ELEVATOR PIT

  • 831005 007703 C30D001 RB DECON-282' ELEV 2 IC 0.317 2.07 PUMP & F LUSH ELEVATOR PIT
  • 831005 007703 C30D001 RB DECON-282' ELEV 1 CM 0.175 1.10 PUMP & FLUSH ELEVATOR PIT
  • 831005 007703 C300001 RB DECON-282' ELEV 1 UM 0.250 1.08 PUMP & F LUSH ELEVATOR PIT
  • 831005 007703 C30D001 RB DECON-282
  • ELEV 2 HP 0.447 2.35 PUMP & FLUSH ELEVATOR PIT 831010 007723 C30D001 RB DECON-282' ELEV 2 OP 0.227 3.37 FLUSH ELEVATOR - 323* LEVEL
  • 831010 007723 C30D001 RB DECON-282* ELEV 2 UM 0.350 3.25 FLUSH ELEVATOR - 323' LEVEL
  • 831010 007723 C30D001 RB DECON-282* ELEV 2 CM 0.242 3.48 FLUSH ELEVATOR - 323' LEVEL
  • 831010 007723 C30D001 RB DECON-282' ELEV 1 EL 0.133 1.55 FLUSH ELEVATOR - 323' LEVEL
  • 831010 007723 C30D001 RB DECON-282
  • ELEV 1 CN 0.103 1.72 FLUSH ELEVATOR - 323' LEVEL 831018 007786 C30D001 RB DECON-282* ELEV 1 OP 0.097 1.97 FLUSH AND PUMP ELEVATOR PIT
  • 831018 007786 C30D001 RB DECON-282* ELEV 1 bM 0.075 1.95 FLUSH AND PUMP ELEVATOR PIT 840130 008348 C300001 RB DECON-282' ELEV 4 CN 0.692 8.47 FLUSH VALVE SFV-104 & SURROUNDING AREA 840210 008432 C30D001 RB DECON-282* ELEV 4 CN 0.574 8.23 FLUSH VALVE SFV-104 & SURROUNDING AREA

. SUBTOTAL - EXP TRCK NUMBER = C30D001 PERS ENTR 138 13.438000 EXPOS REM = s TIME HOURS = 231.05000 gj. 820712 004265 C30E001 DECON RB D RINGS 4 CN 1.078 8.92 REMOTE FLUSH OF 'D' RING 830113 005559 C30E001 DECON RB D RINGS 1 FN 0.543 1.70 PORV PROTECTION

  • 830113 005559 C30E001 DECON RB D RINGS 1 RP 0.620 1.70 PORV PROTECTION pg e
  • 830113 005559 C30E001 DECON RB D RINGS 1 HP 0.182 1.60 PORV PROTECTION 830121 005628 C30E001 DECON RB D RINGS 1 EL 0.124 1.80 DECON ELEVATOR. RVHSS &

'A' D RING

  • 830121 005628 C30E001 DECON RB D RINGS 1 IC 0.107 1.75 DECON ELEVATOR. RVHSS &

'A' D RING

  • 830121 005628 C30E001 DECON RB D RINGS 1 UM 0.063 1.22 DECON ELEVATOR, RVHSS &

'A' D RING 830124 005642 C30E001 DECON RB D RINGS 2 CM 0.305 4.08 REMOTE FLUSH OF MISSILE SHIELD

  • 830124 005642 C30E001 DECON RB D RINGS 1 EL 0.175 2.35 REMOTE FLUSH OF MISSILE SHIELD 3830124 005642 C30E001 DECON RB D RINGS 2 IC 0.174 3.47 REMOTE FLUSH OF MISSILE SHIELD
  • 830124 005642 C30E001 DECON RB D RINGS 1 UM 0.115 1.58 REMOTE FLUSH OF MISSILE SHIELD 830207 005758 C30E001 DECON RB D RINGS 19 CN 3.154 37.68 REMOTE FLUSH - SERV. STRUCT. &

'D' RING 830217 005852 C30E001 DECON RB D RINGS 1 UM 0.083 1.42 REMOTE FLUSH OF 'D' RING / SORT TOOLS

  • 830217 005852 C30E001 DECON RB D RINGS 1 EL 0.247 2.57 REMOTE FLUSH OF

'O' RING / SORT TOOLS

  • 830217 005852 C30E001 DECON RB D RINGS 2 CM 0.301 4.03 REMOTE FLUSH OF

'O' RING / SORT TOOLS 830222 005877 C30E001 DECON RB D RINGS 2 UM 0.395 5.47 PEMOTE FLUSH OF 'O' RING / SORT TOOLS

  • 830222 005877 C30E001 DECON RB D RINGS 1 OP 0.143 2.18 REMOTE FLUSH OF
  • D' RING / SORT TOOLS

$830222 005877 C30E001 DECON RB D RINGS 1 CM 0.142 2.25 REMOTE FLUSH OF 'D' RING / SORT TOOLS 841204 010397 C30E001 DECON RD D RINGS 3 CN 0.300 4.03 D RING TEMPORARY LIGHTING

  • 841204 010397 C30E001 DECON RB D RINGS 1 HP 0.195 1.38 D RING TEMPORARY LIGHTING

. SUBTOTAL - EXP TRCK NUMBER . C30E001 47 PERS ENTR 8.4460000 EXPOS REM TIME HOURS. 91.180000 841205 010409 C30E002 DECON 'A' D RING 2 OP 0.329 2.70 FLUSH

  • A* D RING
  • 841205 010409 C30E002 DECON *A' D RING 3 HP 0.474 4.73

' FLUSH 'A' D RING

  • 841205 010409 C30E002 DECON

'A* D RING 2 UM 0.439 3.23 FLUSH 'A' D RING

  • 841205 010409 C30E002 DECON

'A' D RING 1 IC 0.197 1.53 FLUSH 'A' D RING

  • 341205 010409 C30E002 DECON

'A' D RING 1 MM 0.173 1.50 FLUSH

  • A' D RING
  • 841205 010409 C30E002 DECON

'A' D RING 1 CN 0.145 1.48 FLUSH *A' D RING 1

DATE 022486 PAGE 40 PNG 39 .TMI-2 UNC-DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • .... E... NUMB E. R.* NUMB E R..

...........I.VITY.......................

  • DAT ACT ENTR

. CODE ........ REM........ HOURS............. TASK DE.SCR I.P TI.ON........................ 841207 010425 C30E002 CECON 'A' D RING 1 CN 0.081 0.95 AIRBORNE CONTAMINATION CONTROL 850111 010649 C30E002 CECON 'A' D RING 3 CN 1.329 3.25 APPLY FLUORESCENT TAPE TO ACCESS LADDER 850100 010780 C30E002 CECON

  • A' D RING 3 CN 0.598 5.38 OBTAIN BORON SAMPLE FROM

'A' OTSG/ FLUSH

  • 850130 010780 C30E002 DECON
  • A' D RING 1 RP 0.190 2.12 OBTAIN BORON SAMPLE FROM

'A' OTSG/ FLUSH 3850130 010780 C30E002 DECON 'A' D RING 1 HP 0.075 1.18 OBTAIN BORON SAMPLE FROM 'A' OTSG/F LUSH

  • 850130 010780 C30E002 DECON

'A' D RING 2 OP 0.320 3.18 OBTAIN BORON SAMPLE FROM 'A' OTSG/ FLUSH 850212 010867 C30E002 DECON 'A' D RING 9 CN 2.197 15.53 FLUSH COMPONENTS IN 'A' D RING 850215 010900 C30E002 DECON 'A' D RING 3 CN 0.721 4.98 FLUSH PZR INTERNALS UNDER INSUL. PANELS 850225 010963 C30E002 DECON

  • A' D RING 3 CN 0.697 6.78 FLUSH & DECON MIRROR INSULATION PANEL

. SUBTOTAL - EXP TRCK NUMBER = C30E002 PERS ENTR 36 EXPOS REM . 7.9650000 TIME HOURS = 58.520000 . 841207 010422 C30E003 DECON 'B' D RING 2 OP 0.339 3.82 FLU $H INSIDE OF 'B' O RING FROM 367'ELEV

  • 841207 010422 C30E003 DECON
  • B' D RING 1 IC 0.159 2.18 FLUSH INSIDE OF

'B' D RING FROM 367'ELEV

  • 841207 010422 C30E003 DECON
  • B' D RING 1 MM 0.146 1.60 FLUSH INSIDE OF

'B' D RING FROM 367'ELEV 841227 010555 C30E003 DECON

  • B' D RING 2 CN 0.300 4.20 PLACE & RETRIEVE TLD STRING-367'D RING 850108 010628 C30E003 DECON

'B' D RING 3 CN 0.425 5.88 PLACE & RETRIEVE TLD STRING-367'D RING

  • 850108 010628 C30E003 DECON

'B' D RING 1 MM 0.040 0.72 PLACE & RETRIEVE TLD STRING-367'D RING 8 *850108 010628 C30E003 DECON 'B'.D RING 1 ES 0.204 2.77 PLACE & RETRIEVE TLD STRING-367'O RING . SUBTOTAL - EXP TRCK NUMBER C30E003 00 PERS ENTR. 11 Y EXPOS REM 1.6130000 = TIME HOURS. 21.170000 .850321 011188 C30E006 MEAS. FUEL-LOWER RV 14 CN 2.725 40.41 INCORE PROBE OF MAT *L IN RX VESSEL

  • 850321 011188 C30E006 MEAS. F U E L-L-OWE R RV 1 HP 0.233 3.12 INCORE PROBE OF FMT'L IN RX VESSEL

. SUBTOTAL - EXP TRCK NUMBER = C30E006 PERS ENTR 15 = EXPOS REM . 2.9530000 TIME HOURS. 43.530000 .830630 006847 C30F001 DECON RB CANAL 1 HP 0.009 2.47 DECON SOURCE RANGE PLATE

  • 830630 006847 C30F001 DECON RB CANAL 1 RP 0.005 2.45 DECON SOURCE RANGE PLATE 831005 007704 C30F001 DECON RB CANAL 4 CN 0.284 6.62 FLUSH DEEP END OF FUEL CANAL 850116 010686 C30F001 DECON RB CANAL 6 CN 0.161 10.87 HANDS ON DECON OF FUEL TRANSFER CANAL 850226 010990 C30F001 DECON RB CANAL 4 CN 0.520 11.00 PUMP OUT FUEL ARRAY PIT 850306 011062 C30F001 DECON RB CANAL 8 CN 0.399 11.93 HIGH PRESSURE FLUSH OF FUEL STORAGE RACK 850313 011111 C30F001 DECON RB CANAL 5 CN 0.231 7.23 F LUSH FUEL R ACK/ HANDS ON DECON
  • 850313 011111 C30F001 DECON RB CANAL 1 HP 0.027 1.60 FLUSH FUEL RACK / HANDS ON DECON 850320 011174 C30F001 DECON'RB CANAL 4 CN 0.291 7.10 INSTALL SCAFFOLD IN REFUEL CANAL 850325 011201 C30F001 DECON RS CANAL 10 CN 0.790 22.05 FILL DRUM / MOVE TO CADLE TRAY / FLUSH TRAY 850325 011202 C30F001 DECON RB CANAL 40 CN 1.470 76.02 STAGE EQUIP / HOOK UP KELLY / FLUSH CANAL

. SUBTOTAL - EXP TRCK NJMBER . C30F001 PERS ENTR 84 = EXPOS REM 4.1870000 TIME HOURS 159.34030 = .811027 002273 C30G001 DECON EXP-SDS SURVEY 1 CN 0.416 1.82 GEN. SURVEY /SDS LINE SURVEY 811105 002349 C30G001 DECON E XP-SDS SURVEY 1 HP 0.300 1.83 GEN. SURVEY /SDS LINE SURV/ AIR SAMPLE 811113 002427 C30G001 DECON E XP-SDS SURVE Y ! HP 0,240 1.55 FIXED POINT SURVEY /SDS LINE SURVEY 811203 002550 C30G001 DECON EXP-SDS SURVEY 1 CN 0.344 1.50 GEN. SURVEY /SDS LINE SURVEY / AIR SAMPLE 811209 002584 C30G001 DECON EXP-SDS SURVEY 1 HP 0.181 0.92 FIXED POINT SURVEY / AIR & TRITIUM SAMPLES l

i DATE 022486 PAGE 41 PNO 40 TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME, TASK DESCRIPTION s....... NUMBER. NUMBER.....................IVITY ............,....... CODE........ HOURS........,................................................, . ENTR . REM

  • DATE ACT 811215 002630 C30G001 DECON EXP-SDS SURVEY 1 HP 0.173 0.98 REMOVE TLD*S/ PROTECT HPR-214 811215 002631 C30G001 DECON EXP-SDS SURVEY

! HP 0.105 0.52 HP SURVEY / AIR SAMPLES 811217 002660 C30G001 DECON EXP-SDS SURVE Y 1 HP 0.250 0.82 HP SURVEY / AIR SAMPLES 820105 002763 C30G001 DECON EXP-SDS SURVEY 1 UM 0.427 1.08 HP SURVEY 820107 002785 C30G001 DECON EXP-SDS SURVEY 1 CN 0.350 1.08 HP SURVEY 820114 002824 C30G001 DECON EXF-SDS SURVE Y 1 CN 0.511 2.33 HP SURVEY - FIXED POINTS 820126 002897 C30G001 DECON EXP-SDS SURVEY 1 CN 0.644 1.83 HP SURVEY /SDS LINE/ ROPE OFF STAIRS 820128 002916 C30G001 DECON EXP-SDS SURVEY 1 CN 0.034 0.50 HP SURVEY / AIR SAMPLES /0XYGEN ANAL. 820202 002950 C30G001 DECON EXP-SDS SURVEY 1 CN 0.471 1.42 HP SURVEY /SDS LINE/ AIR SAMPLES 820204 002962 C30G001 DECON EXP-SDS SURVEY 1 HP 0.303 2.45 HP SURVEY & JOB COVERAGE 820216 003047 C30G001 DECON EXP-SDS SURVEY 1 HP 0.280 1.50 HP SURVEY /SDS LINE/ SAMPLES 820217 003070 C30C001 DECON E XP-SDS SURVE Y 1 HP 0.014 1.67 COLLECT PARTICULATE & TRITIUM SAMPLES 820219 003086 C30G001 DECON EXP-SDS SURVEY 2 HP 0.135 1.58 SPECIAL GAS MONITORING ;EAM

  • 820219 003086 C30G001 DECON E XP-SDS SURVEY 1 CN 0.000 0.67 SPECIAL GAS MONIl0 RING TEAM

$820219 003086 C30G001 DECON EXP-SDS SURVEY ! AD 0.124 1.08 SPECIAL GAS MONITORING TEAM 820219 003089 C30G001 DECON EXP-SDS SURVEY I OP 0.092 0.27 SPECI AL ENTRY

  • 820219 003089 C30G001 DECON E XP-5DS SURVEY 2 CN 0.197 0.53 SPECI AL ENTRY 820220 003090 C30G001 DECON EXP-SDS SURVEY 1 OP 0.003 0.47 SPECI AL-E NTRY
  • S20220 003090 C30G001 DECON EXP-SDS SURVEY 3 CN 0.195 1.29 SPECIAL ENTRY a *820220 003090 C30G001 DECON E XP-SDS SURVEY 1 AD 0.100 0.42 SPECIAL ENTRY N

820224 003117 C30G001 DECON EXP-SDS SURVEY 1 AD 0.111 0.58 COMBUSTIDLE GAS SAMPLE 45 *820224 003117 C30G001 DECON EXP-SDS SURVEY 2 CN 0.185 1.17 COMBUSTIBLE GAS SAMPLE 8 820224 003125 C30G001 DECON EXP-SDS SURVEY 1 CN 0.135 1.33 HP SURVEY /SDS LINE SURVEY 820225 003132 C30C001 DECON EXP-SDS SURVEY 1 CN 0.386 1.22 HP SURVEY /SDS LINE/ SAMPLES 820225 003136 C30G001 DECON E XP-SDC SURVEY I CN 0.291 2.67 HP SURVEY / AIR SAMPLES / JOB SUPPORT 820302 003171 C30G001 DECON E XP-SDS SURVEY 1 CN 0.228 1.33 FIXED POINT SURVEYS /SDS LINE/ SAMPLES 820303 003184 C30G001 DECON EXP-SDS SURVEY 2 HP 0.157 4.65 HP SURVEYS & JOB COVERAGE

  • 820303 003184 C30G001 DECON EXP-SDS SURVEY 2 CN 0.122 2.75 HP SURVEYS & JOB COVERAGE 820305 003202 C30G001 DECON EXP-SDS SURVEY 8 CN 0.020 21.50 REPLACE PULSATION DAMPENER 820308 003212 C30G001 DECON EXP-SDS SURVEY 9 HP 1.280 23.15 HP SURVEYS /DECON EXPERIMENT COVER AGE
  • 820308 003212 C30G001 -DECON EXP-SDS SURVEY 1 CN 0.065 3.08 HP SURVEYS /DECON EXPERIMENT COVERAGE 820315 003279 C30G001 DECON EXP-SDS SURVEY 6 HP 0.773 15.23 HP SURVEYS /DECON EXPERIMENT COVERAGE
  • 820315 003279 C30G001 DECON EXP-SDS SURVEY 2 CN 0.072 4.70 HP SURVEYS /DECON EXPERIMENT COVERAGE 830322 003340 C30G001 DECON EXP-SDS SURVEY 2 HP 0.045 2.08 HP SURVEYS /DECON EXPERIMENT COVERAGE

$830322 003340 C30G001 DECON EXP-SDS SURVEY 3 CN 0.578 4.95 HP SURVEYS /DECON EXPERIMENT COVERAGE 830414 003565 C30G001 DECON EXP-SDS SURVEY 1 HP 0.089 1.33 HP SURVEYS / JOB COVERAGE 830422 003640 C30G001 DECON EXP-SDS SURVEY 1 HP 0.025 0.63 HP SURVEY / AIR SAMPLE 830428 003702 C30G001 DECON E XP-SDS SURVE Y 1 CN 0.255 2.87 HP SURVEY / JOB COVERAGE 830505 003765 C3GG001 DECON EXP-SDS SURVEY 1 HP 0.390 3.08 HP SURVEY / JOB COVERAGE 830510 003805 C30G001 DECON EXP-SDS SURVEY I HP 0.100 1.08 HP SURVEY / JOB COVERAGE 830610 004040 C30G001 CECON EXP-SDS SURVEY 4 CN 0.631 6.50 LIQUID TRANSFER / RAD WASTE PACKAGING 830707 004228 C30G001 DECON EXP-SDS SURVEY 1 HP 0.050 2.75 HP SURVEY / JOB COVERAGE

SUBTOTAL -

EXP TRCK AUMBER.. C30G001 81 PERS ENTR . EXPOS REM = !!.877000 138.74000 TIME HOURS = ,811029 002296 C30G002 DECON EXP-GAMMA SPEC 2 CN 0.640 7.08 GAMMA SPEC READINGS - AIR COOLERS 811209 002590 C30G002 DECCN EXP-GAMMA SPEC 3 CN 1.036 7.28 CONTAINMENT CHARACTERIZATION & SAMPLING $811209 002590 C30G002 DECON EXP-GAMMA SPEC 1 CR 0.160 2.70 CONTAINMENT CHARACTERIZATION & SAMPLING 811215 002633 C30G002 DECON EXP-GAMMA SPEC 2 CN 0.730 5.17 CONTAINMENT CHARACTERIZATION

I I DATE 022486 PAGE 42 PNO. 41 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • ............................... T. I V I. T. Y........................C. ODE........ HOURS....................T AS.K D.E.SCR I P T ION AC ENTR

. REM

  • D. ATE. NUMBER. NUMBER
  • 811215 002633 C30G002 DECON EXP-GAMMA SPEC 1 CR 0.597 3.50 CONTAINMENT CHARACTERIZATION 811216 003049 C30G002 DECON EXP-GAMMA SPEC 4 CN 0.988 5.38 RIG GAMMA SPECTROMETER & TAKE READINGS
  • 811216 003049 C30G002 DECON EXP-GAMMA SPEC 1 CR 0.515 3.92 RIG GAMMA SPECTR0ftETER & TAKE READINGS 820224 003116 C30G002 DECON EXP-GAMMA SPEC 2 CN 0.202 1.67 REMOVE GAMMA SPECTROMETER FROM RB 820322 003342 C30G002 DECON EXP-GAMMA SPEC 9 CN 1.792 15.97 RIG EQUIP. FROM DECON TEST - 305' & 347' 820322 003343 C30G002 DECON EXP-GAMMA SPEC 3 CN 1.226 9.00 GAMMA SPEC & RO-2A MEAS / PLACE TLDS
  • 820322 003343 C30G002 DECON EXP-GAMMA SPEC 1 CR 0.378 3.08 GAMMA SPEC & R0-2A ME AS/PL ACE TLDS 820422 003642 C30G002 DECON EXP-GAMMA SPEC 2 CN 0.422 3.67 REMOVE TLD*S 220513 003845 C30G002 DECON EXP-GAMMA SPEC 1 CN 0.127 1.20 REMOVE IODINE SAMPLERS

. SUBTOTAL - EXP TRCK NUMBER . C30G002 32 PERS ENTR = EXPOS REM . 8.8130000 TIME HOURS. 69.620000 .811027 002277 C30G003 DECON EXP-DATA ACQUI 2 CN 0.515 2.67 SNUB 8ER INSP./ PHOTO INSULATION REMOVAL 811027 002274 C30G003 DECON EXP-DATA ACQUI 1 CN 0.056 0.75 PHOTOGRAPH AREAS ON 305' & 347' LEVELS 811028 002271 C30G003 DECON E XP-DATA ACQUI 2 CN 0.224 2.83 VIDEOTAPE AREAS ON 305' & 347' LEVELS 811113 002426 C30G003 DECON E XP-DATA ACQUI 1 OP 0.340 1.00-COLLECT BIOLOGICAL SAMPLES 811113 002423 C30G003 DECON EXP-DATA ACQUI 2 CN 0.233 2.04 REPLACE HP-R-212 & SOLENOID 811113 002424 C30G003 DECON EXP-DATA ACQUI 1 CN 0.233 1.33 PHOTOGRAPH 347' ELEVATION 1 811117 002446 C30G003 DECON EXP-DATA ACQUI 2 CN 0.137 2.17 INSTALL RAMP EXTENSION m 811117 002447 C30G003 DECON EXP-DATA ACQUI 1 CN 0.203 1.17 PHOTOGRAPH 305' & 347' LEVELS on 811120 002477 C30G003 DECON EXP-DATA ACQUI 3 CN 0.944 5.33 LOAD & TEST HIGH REACH LIFT PLATFORM e 811120 002478 C30G003 DECON EXP-DATA ACQUI 1 CR 0.074 0.83 TEST VIDEO TAPING EQUIPMENT 811209 002585 C30G003 DECON EXP-DATA ACQUI 1 CN 0.090 0.05 REPLACE HP-R-212

  • 811209 002585 C30G003 DECON EXP-DATA ACQUI I IC 0.100 0.05 REPLACE HP-R-212 811215 002634 C30G003 DECON EXP-DATA ACQUI 1 OP 0.195 0.68 CLOSE AIR DUCT DAMPERS TO 282' LEVEL 811215 002635 C30G003 DECON EXP-DATA ACQUI 1 OP 0.437 1.73 HYDROGEN BURN CHARACTERIZATION 811215 002632 C30G003 DECON EXP-DATA ACQUI 3 CN 0.886 6.08 COLLECT SURFACE DEPOSITION SAMPLES
  • 811215 002632 C30G003 DECON EXP-DATA ACQUI 2 CR 0.580 3.75 COLLECT SURFACE DEPOSITION SAMPLES
  • 811215 002632 C30G003 DECON EXP-DATA ACQUI 1 HP 0.190 2.42 COLLECT SURFACE DEPOSITION SAMPLES 811217 002659 C30G003 DECON EXP-DATA ACQUI 5 CR 2.192 9.63 SURFACE DEPOSITION SAMPLING
  • 811217 002659 C30G003 DECON EXP-DATA ACQUI 1 CN 0.519 2.05 SURFACE DEPOSITION SAMPLING 820105 002761 C30G003 DECON E XP-DATA ACQUI 1 CN 0.160 2.58 HYDROGEN BURN CHAR / TEST RADIOS 820126 002898 C30G003 DECON EXP-DATA ACQUI 4 CN 2.117 10.67 VIDEOTAPING 820204 002963 C30G003 DECON EXP-DATA ACQUI 1 HP 0.346 1.18 IDENTIFY DRUM CONTENTS 820216 003C48 C30G003 DECON EXP-DATA ACQUI 1 CN 0.152 1.07 PRE-DECON PHOTOGRAPHS 820324 003367 C30G003 DECON E XP-DAT A ACQUI 1 CN 0.071 1.67 POST-DECON PHOTOGRAPHS

-820325 003379 C30G003 DECON EXP-DATA ACQUI 1 HP 0.246 2.67 COLLECT SURFACE DEPOSITION SAMPLES

  • 820325 003379 C30G003 DECON E XP-DATA ACQUI 5 OP 1.228 11.07 COLLECT SURFACE DEPOSITION SAMPLES
  • 820325 003379 C30G003 DECON E XP-DATA ACQUI 6 CN 1.693 12.36 COLLECT SURFACE DEPOSITION SAMPLES 820513 003842 C30G003 DECON E XP-DATA ACQUI 1 ES 0.125 1.53 REMOTE SURVEY OF

'D' RINGS 820610 004038 C30G003 DECON EXP-DATA ACQUI 2 CN 0.334 3.33 POST-DECON DATA ACQUISITION 820730 004401 C30G003 DECON E XP-DATA ACQUI 1 DM 0.005 0.25 OPEN DRUM IN COMPACTOR ROOM 820812 004490 C30G003 DECON EXP-DATA ACQUI 2 CN 0.248 3.00 POST-DECON DATA ACQUISITION-STRIPCOAT .SUST0TAL - EXP TRCK NUMBER = C30G003 PERS ENTR. 58 . EXPOS REM

14.873000 97.940000 TIME HOURS

811105 002351 C30G004 DECON EXP-NRC INSP 13 CN 0.059 39.09 RB ENTRY SUPPORT

  • 811105 002351 C30G004 DECON EXP-NRC INSP 2 UM 0.030 4.75 RB ENTRY SUPPORT

._m 1 i i DATE 022486 PAGE 43 PNO. 42 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME i

  • D AT.E.. N UMBE.R. NUMB E R....................I.VIT.Y.......

. ENTR. COD.E. REM....... H. OUR S............... T. ASK..D E.S.C R I P. T. I.ON........................, t ACT

  • 311105 002351 C30G004 DECON EXP-NRC INSP 1 OP 0.000....

1.50 RB ENTRY SUPPORT $311105 002351 C30G004 DECON EXP-NRC INSP 5 CR 0.035 10.58 RB ENTRY SUPPORT

  • 811105 002351 C30G004 DECON EXP-NRC INSP 3 HP 0.000 13.25 RB ENTRY SUPPORT 811113 002422 C30G004 DECON EXP-NRC INSP 2 OP 0.000 2.50 RB ENTRY SUPPORT 4

4

  • 811113 002422 C30G004 DECON EXP-NRC INSP 1 MM 0.000 3.17 RB ENTRY SUPPORT
  • 811113 002422 C30G004 DECON EXP-NRC INSP 3 CR 0.020 8.50 RB ENTRY SUPPORT
  • 811113 002422 C30G004 DECON EXP-NRC INSP 9 CN 0.043 33.03 RB ENTRY SUPPORT
  • 811113 002422 C30G004 DECON EXP-NRC INSP 2 AD 0.000-0.33 RB ENTRY SUPPORT
  • 811113 002422 C30G004 DECON EXP-NRC INSP 3 HP 0.002 18.37 RB ENTRY SUPPORT 811209 002582 C30G004 DECON EXP-NRC INSP 20 CN 0.013 91.40 RB ENTRY SUPPORT

$311209 002582 C30G004 DECON EXP-NRC INSP 1 OP 0.000 1.33 RB ENTRY SUPPORT

  • 811209 002582 C30G004 DECON EXP-NRC INSP 3 HP 0.000 27.78 RB ENTRY SUPPORT 820202 002951 C30G004 DECON EXP-NRC INSP 19 CN 0.030 64.91 RB ENTRY SUPPORT l

$820202 002951 C30G004 DECON EXP-NRC INSP 3 HP 0.000 21.67 RB ENTRY SUPPORT 820204 002964 C30G004 DECON EXP-NRC INSP 1 CN 0.364 1,32 RAD SURVEY /NRC INSPECTION i 1 HP 0.374 1.38 RAD SURVEY /NRC INSPECTION

  • 820204 002964 C30G004 DECON EXP.-NRC INSP

. SUBTOTAL - EXP TRCK NUMBER C30G004 d 92 PERS ENTR = 4 EXPOS REM 0.970C000 . TIME HOURS

  • 344.86000 na 791015 028776 C30G005 DECON EXP-CCTV RELOC 13 CN 0.028 0.00 INSTALL EQUIP / DRILL FLANGE ch *791015 028776 C30G005 DECON EXP-CCTV RELOC 1 CR 0.000 0.00 INST ALL EQUIP / DRILL F LANGE e

811209 002587 C30G005 DECON EXP-CCTV RELOC 1 CN 0.250 1.48 CCTV REPAIR 3811209 002587 C30G005 DECON EXP-CCTV RELOC 1 IC 0.260 1.48 CCTV REPAIR 320303 003185 C30G005 DECON EXP-CCTV RELOC 1 CN 0.399 2.18 CCTV REPAIR 2820303 003185 C30G005 DECON EXP-CCTV RELOC 1 CR 0.390 2.27 CCTV REPAIR l 820428 003701 C30G005 DECON E XP-CCTV RELOC 1 IC 0.302 2.67 CCTV REPA1R

  • 820428 003701 C30G005 DECON EXP-CCTV RELOC 1 CN 0.322 2.67 CCTV REPAIR 820603 003997 C30G005 DECON EXP-CCTV RELOC 2 CN 0.326 4.83 RELOCATE CCTV 3820603 003997 C30G005 DECON E XP-CCTV RELOC 1 IC 0.207 2.41 RELOCATE CCTV e

. SUBTOTAL - EXP TRCK NUMBER = C30G005 ) PERS ENTR. 23 . EXPOS REM 2.4840000 19.990000 TIME HOURS 1 820216 003045 C30G006 DECON EXP-REENER 305 3 CN 0.443 3.37 INSTALL 110V SERVICE TO 305* LEVEL 4 i 820226 003139 C30G006 DECON EXP-REENER 305 ' 3 CN 0.121 1.83 INSTALL 110V VAC EXTENSION ON 347' LEVEL . SUBTOTAL - EXP TRCK NUMBER . C30G006 6 PERS ENTR ]- . EXPOS REM = 0.5640000 r TIME HOURS. 5.2000006 J .820325 00337. C30G007 DECON EXP-VIDEOTAPE 2 CN 0.740 6.42 VIDEOTAPE DECON OPERATIONS 2820325 00337 C30G007 DECON EXP-VIDEOTAPE 2 CR 0.724 6.63 VIDEOTAPE DECON OPERATIONS 820331 003438 C30G007 DECON EXP-VIDEOTAPE 1 CN 0.097 1.58 POST-DECON OPERATIONS 820504 006423 C30G007 DECON EXP-VIDEOTAPE 2 CN 0.336 4 12 PHOTOGRAPH / INSPECT SNUBBERS & HANGERS . SUBTOTAL - EXP TRCK NUMBER = C30G007 = 7 PERS ENTR . EXPOS REM . 1.8970000 18.750000 TIME HOURS ,811203 002551 C30G008 DECON EXP-EQUIP PROT 1 CN 0.121 ' 1.30 SURVEY / PROTECT / PHOTO HP-R-214 811209 002588 C30G008 DECON EXP-EQUIP PROT 3 CR 1.212 _ 6,27 EQUIP. PROT. - 305*c 347' & *D' RINGS I 1 = i e n

DATE 022486 PAGE 44 PNO. 43 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PLRS. DEPT. EXPOS. TIME

  • D A T E... NUMBE. R, NUMBE.R........................._.................. REM........ HOURS.

TASK DESCRIPTION ACTIVITY . ENTR. CODE 1.553 6.20 EQUIP. PROT. - 305*. 347* & 'D' RINGS

  • 811209 002588 C30G003 DECON EXP-EQUIP PROT 3 OP 820226 003138 C30G008 DECON E XP-EQUIP PROT 3 CN 0.276 2.80 POLAR CRANE EQUIP PROT.

820226 003140 C30G008 DECON E XP-EQUIP PROT 3 CR 1.059 6.15 PROTECT / RELOCATE CCTVS 4820226 003140 C30G008 DECON EXP-EQUIP PROT 1 HP 0.361 3.80 PROTECT / RELOCATE CCTVS . SUBTOTAL - EXP TRCK NUMBER . C30G008 14 PERS ENTR EXPOS REM = 4.5820000 TIME HOURS. 26,520000 .811027 002276 C30G009 DECON EXP-SERVICES 2 FH 0.103 2.00 INSTALL BLANK FLANGE - PENET R-561 320211 003027 C30G009 DECON E XP-SERVICES 4 CN 0.014 5.47 LEAK TEST PENET R561/ INSTALL FLANGE 820218 003066 C30G009 DECON EXP-SERVICES 1 CR 0.000 1.17 LEAK TEST PENET RS61/ INSTALL FLANGE

  • 820218 003066 C30G009 DECON EXP-SERVICES 10 CN 0.022 19.75 LE AK TEST PENET RS61/ INSTALL FLANGE 820224 003131 C30G009 DECON EXP-SERVICES 6 CN 0.003 8.23 LEAK TEST PENET R-561 820224 003114 C30G009 DECON EXP-SERVICES 2 CN 0.539 3.92 STAGE DECON HOSES / TEST SYSTEM 820224 003118 C30G009 DECON E XP-SERVICES 3,C N 0.281 4.50 INST / TEST DECON TEST FLANGE-PENET R-561 820224 003119 C30G009 DECON E XP-SERVICES 1 CN 0.235 1,47 SAFETY INSPECTION - RB 820322 003341 C30G009 DECON EXP-SERVICES 2 CN 0.220 3.58 INSTALL SERVICE AIR HOSES

. SUBTOTAL - EXP TRCK NUMBER . C30G009 e PERS ENTR. 31 1.4170000 EXPOS REM d 50.090000 PJ TIME HOURS = '4 810123 000190 C30G010 DECON EXP-CLEANUP 2 CR 0.025 6.00 MOVE BUSS BARS TO DECON TENT 3810123 000190 C30G010 DECON EXP-CLEANUP 1 CN 0.010 2.92 MOVE BUSS BARS TO DECON TENT 810123 000196 C30G010 DECON EXP-CLEANUP 1 CR 0.000 0.33 MOVE BUSS BARS TO ELEC. CONTR. TRAILER

  • 810123 000196 C30G010 DECON EXP-C(EANUP 1 CN 0.000 0.08 MOVE BUSS BARS TO ELEC. CONTR. TRAILER 810209 000361 C30G010 DECON EXP-CLEANUP 2 CR 0.035 2.50 REMOVE HERCULITE/DECON AIRLOCK
  • 810209 000361 C30G010 DECON EXP-CLEANUP 1 UM 0.000 1.25 REMOVE HERCULITE/DECON AIRLOCK
  • 810209 000361 C30G010 DECON EXP-CLEANUP 1 CN 0.010 1.25 REMOVE HERCULITE/DECON AIRLOCK 811027 002272 C30G010 DECON E X P-CLE ANUP 6 CN 2.224 11.87 TRASH PICKUP / MOVE EQUIPMENT 811029 002294 C30G010 DECON EXP-CLE ANUP 1 HP 0.323 1.25

$URVEY HPR-212 & STORAGE AREAS 811029 002295 C30G010~ DECON EXP-CLEANUP 4 CN 0.786 6.00 PICK UP TRA(.H/ MOVE EQUIPME NT 811105 002350 C30G010 OECON E X P-CLE ANUP 6 CR 2.124 9.63 ARE A CLE ant?-305 * & 34 7

  • LEVELS 811113 002425 C30G010 DECON EXP-CLEANUP 2 CN 0.674 2.45 GENERAL CLEANUP / MOVE EQUIPMENT 820318 003322 C30G010 DECON EXP-CLEANUP 4 CR 1.5W4 9.33 REMOVE TRASH 820331 003439 C30G010 DECON E XP-CLE ANUP 7 CN 2.337 17.55 REMOVE TRASH 820428 003703 C30G010 DECON E XP-CLE ANUP 2 CN 0.363 3.00 STAGE TRASH FOR REMOVAL 820505 003786 C30G010 DECOR EXP-CLEANUP 2 CN 0.267 4.58 REMOVE WASTE. SAMPLERS & CCTV CONTROLS 320526 003950 C30G010 DECON EXP-CLEANUP 2 CN 0.341 2.75 CLEAN STAGING AREA / TRANSFER LIQUIDS 820707 004231 C30G010 DECON E XP-CLE ANUP 2 CN 0.355 3,08 TRASH CLEANUP 820707 004232 C30G010 DECON E XP-CLE ANUP 2 CN 0.627 2.83 TRASH CLEANUP 820707 004233 C30G010 DECON EXP-CLEANUP 2 CN 0.300 2.50 TOOL INVENTORY 820712 004270 C30G010 DECON EXP-CLEANUP 1 CN 0.005 6.50 OPERATE AND MAINTAIN NLB PUMP

. SUBTOTAL - EXP TRCK NUMBER . C30G010 52 PERS ENTR = EXPOS REM . 12.400000 97.650000 TIME HOURS .811203 002553 C30G011 DECON EXP-RADIO TEST 1 IC 0.300 2.42 NEW RADIO SYSTEM /CCTV REPAIR 8811203 002553 C30G011 DECON EXP-RADIO TEST 1 CR 0.694 2.42 NEW R ADIO SYSTEM /CCTV RE PAIR 811209 002586 C30G011 DECON EXP-RADIO TEST 1 CN 0.104 0.73 PROTECT PENET R-507 & CCTV JUNCTION BOX $811209 002586 C30G011 DECON EXP-RADIO TEST 1 IC 0.068 0.73 PROTECT PENET R-507 & CCTV JUNCTION BOX

DATE 022486 PAGE 45 PNO. 44 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCh. PERS. DEPT. EXPOS. TIME ........ E.... R E. M..........................SK DE.SCRIPTION . COD . HOURS TA .......AC.TIVITY............... E.NTR

  • ....... NUMBER.NUMBE.R
  • DATE

. ELECTRICAL WALKDOWN - SPIDER LIFT 820114 002825 C30G011 DECON EXP-RADIO TEST 2 CN 0.639 6.17 . SUBTOTAL - EXP TRCK NUMBER . C30G011 6 PERS ENTR 1.8050000 . EXPOS REM TIME HOURS 12.470000 .811027 002275 C30G012 DECON EXP-HATCH & BEAM 2 CN 0.402 2.83 WALKDOWN/DSMNTL TV CART /RMVE CCTV CNTRL 4 . SUBTOTAL - EXP TRCK NUMBER = C30G012 2 PERS ENTR 0.4020000 EXPOS REM = . TIME HOURS = 2.8300000 820114 002826 C30G013 DECON EXP-SPIDR ELEC 1 CN 0.605 2.58 INSTALL ANTENNA / TEST RADIO SYSTEM 820204 002965 C30G013 DECON EXP-SPIDR ELEC 6 CN 0.800 11.33 ELECTRICAL SERVICE FOR SPIDER LIFT . SUBTOTAL - EXP TRCK NUMBER = C30G013 PERS ENTR. 7 EXPOS REM 1.4050000 TIME HOURS = 13.910000 811117 002448 C30G014 DECON EXP-P.C. SPIDR 4 CN 1.206 9.07 WALKDOWN FOR SPIDER LIFT INSTALLATION

  • 811117 002448 C30G014 DECON EXP-P.C. SPIDR 1 AD 0.283 2.45 WAK%DOWN F OR SPIDE R LIFT INSTALLATION 811203 002552 C30G014 DECON EXP-P.C. SPIDR 4 CN 1.934 10.67 INST ALL GOOSENECKS & LADDER - P.C.

DECON EXP-P.C. SPIDR 1 VI 0.359 3.75 INSTALL'GOOSENECKS & LADDER - P.C. Kj *811203 002552 C30G014 820105 002762 C30G014 DECON E XP-P.C. SPIDR 11 CN 3.170 28.08 INSTALL SPIDER LIFT SUPPORTS C0 820107 002786 C30G014 DECON EXP-P.C. SPIDR 4 CN 1.239 14.50 INSTALL SPIDER LIFT SUPPORTS e 820224 003127 C30G014 DECON EXP-P.C. SPIDR 4 CN 1.343 11.67 INSTALL SPIDER LIF T SAFETY LINES SPIDR 3 CN 0.613 9.67 EQUIPMENT MAINTENANCE 820526 003953 C30G014 DECON EXP.-P.C. C30G014 . SUBTOTAL - EXP TRCK NUMBER 32 PERS ENTR 10.147000 EXPOS REM TIME HOURS. 89.860000 .$20126 002895 C30G015 DECON EXPiSPIDER-347 4 CN 0.015 5.00 LOAD TEST SPIDER SUPPORTS 820202 002948 C30G015 DECON EXP-SPIDER-347 5 CN 2.635 15.75 STAGE SPIDER LIFT IN CONTAINMENT 820202 002949 C30G015 DECON EXP-SPIDER-347 4 CN 1.898 10.83 LOAD TEST SPIDER SUPPORTS / STAGE FORKLIFT 820224 003128 C30G015 DECON EXP-SPIDER-347 4 CN 1.441 10.21 LOAD TEST SPIDER SUPPORTS / REPLACE EQUIP $20224 003128 C30G015 DECON EXP-SPIDER-347 2 MM 0.000 1.67 LOAD TEST SPIDER SUPPORTS / REPLACE EQUIP 820707 004234 C30G015 DECON EXP-SPIDER-347 2 CN 0.102 2.33 SPIDER LIFT MAINTENANCE . SUBTOTAL - EXP TRCK NUMBER . C30G015 21 PERS ENTR . EXPOS REM 6.0910000 TIME HOURS = 45.790000 .820303 003189 C30G016 DECON EXP-LP/HP-305* 5 CN 0.000 22.00 OPERATE DECON WATER NLB PUMP

  • 820303 003189 C30G016 DECON EXP-LP/HP-305*

1 CR 0.000 0.92 OPERATE DECON WATER NLB PUMP 820305 003200 C30G016 DECON E XP-LP/HP-305

  • 13 CN 0.010 51.83 OPERATE HYDROLASER PUMP

$820305 003200 C30G016 DECON E XP-LP/HP-305

  • 1 OP 0.000 0.33 OPERATE HYDROLASER PUMP 820315 003275 C30G016 DECON EXP-LP/HP-305*

5 CR 2.420 10.42 LOW PRESSURE FLUSH OF 305* LEVEL $820315 003275 C30G016 DECON EXP-LP/HP-305* 1 UM 0.360 2.25 LOW PRESSURE FLUSH OF 305* LEVEL 820217 003308 C30G016 CECON EXP-LP/HP-305* 9 CR 3.405 11.67 HIGH PRESSURE FLUSH OF 305* LEVEL

  • 820317 003308 C30G016 DECON E XP-LP/HP-305
  • 1 UM 0.640 1.83 HIGH PRESSURE FLUSH OF 305* LEVEL
  • 820317 003308 C30G016 DECON EXP-LP/HP-305*

1 HP 0.612 1.93 HIGH PRESSURE FLUSH OF 305* LEVEL 820319 003326 C30G016 DECON EXP LP/HP-305* 3 CR 0.864 4.50 LOW PRESSURE FLUSH - 305* FLOOR 1 CN 0.000 4.33 OPERATE NLB HYDROLASER PUMP 820322 003365 C30G016 DECON EXP.LP/HP-305* C30G016 . SUBTOTAL - EXP TRCK NUMBER I

DATE 022486 PAGE 46 PNG. 45 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATTON286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE 3....... NUMBER. NUMBER..................T..IVITY....................E. N T R AC

..... CODE........RCH....... ...............,..............IPT. ION . HOURS TASK DESCR PERS ENTR. 41 . EXPOS REM 8.3110000 = . TIME HOURS = 112.01000 .820308 003214 C30G018 DECON EXP LP MX/CANL 6 CR 1.392 12,42 LP FLUSH OF 0 RINGS & REFUEL POOL AREA

  • 820308 003214 C30G018 DECON EXP LP MX/CANL 7 HP 1.722 15.41 LP FLUSH OF D RINGS & REFUEL POOL AREA 830311 006024 C30G018 DECON EXP LP MX/CANL 3 CN 0.382 4.87 REMOVE INTERFERENCES - RVHSS

. SUBTOTAL - EXP TRCK NUMBER . C30G018 . PERS ENTR 16 . EXPOS REM . 3.4360000 TIME HOURS = 32.700000 .820310 003248 C30G019 DECON EXP-LP/HP 347' 1 CR 0.000 0.25 LOW PRESSURE FLUSH OF 347' LEVEL

  • 820310 003248 C30G019 DECON EXP-LP/HP 347' 3 HP 0.895 7.33 LDW PRESSURE FLUSH OF 347' LEVEL 820311 003256 C30G019 DECON EXP-LP/HP 347' 4 CN 0.008 9.25 DECON/ REPAIR HYDROLASER LANCES 820311 003257 C30G019 DECON EXP-LP/HP 347' 9 CR 1.875 20.20 HIGH PRESSURE FLUSH OF 347' LEVEL
  • 820311 003257 C30G019 DECON EXP-LP/HP 347' 7 HP 1.334 14.55 HIGH PRESSURE FLUSH OF 347' LEVEL
  • 820311 003257 C30G019 DECON EXP-LP/HP 347' 2.UM 0.438 3.75 HIGH PRESSURE FLUSH OF 347' LEVEL 820315 003280 C30G019 DECON EXP-LP/HP 347' 9 CR 1.470 15.97 HIGH PRESSURE FLUSH DATA ACQUISITION
  • 820315 003280 C30G019 DECON EXP-LP/HP 347' 1 HP 0.242 1.83 HIGH PRESSURE FLUSH DATA ACQUISITION

. SUBTOTAL - EXP TRCK NUMBER . C30G019 8 . PERS ENTR 36 = . EXPOS REM = 6.2620000 -d . TIME HOURS 73.130000 DJ 820322 003366 C30G020 DECON EXP-MECH SCRUB 3 AD 0.424 8.42 MECHANIC #L FLOOR SCRUBBER TEST-347' ELEV j3. SUBTOTAL - EXP TRCK NUMBER . C30G020 PERS ENTR = 3 EXPOS REM . 0.4240000 TIME HOURS 8.4200000 = .820324 003368 C30G021 DECON EXP-STRIP COAT 7 CN 2.720 20.22 STRIPPABLE COATING TEST-347'4305' LEVELS .SU8 TOTAL - -EXP TRCK NUMBER . C30G021 PERS ENTR 7 = . EXPOS REM 2 7200000 TIME HOURS 20.220000 .820422 003641 C30G022 DECON EXP-HPR214 RMV 6 CN 1.462 15.42 REMOVE HPR-214 $820422 003641 C30G022 DECON EXP-HPR214 RMV 1 HP 0.130 0.28 REMOVE HPR-214 820603 003996 C30G022 DECON EXP-HPR214 RMV 4 CN 0.134 5.00 REMOVE HPR-214 FROM RB . SUBTOTAL - EXP TRCK NUMBER = C30G022 . PERS ENTR. 11 . EXPOS REM . 1.7260000 TIME HOURS = 20.700000 .821020 004945 C30J001 RB DECON-347' ELEV 4 CN 0.318 4.55 EQUIPMENT PROTECTION - 347' LEVEL 821105 005051 C30J001 RB DECON-347' ELEV 18 RP 3.020 42.60 DECON 347* LEVEL 821112 005091 C30J001 R8 DECON-347' ELEV 4 RP 0.329 7.45 DECON 347' LEVEL 821115 005103 C30J001 RB DECON-347' ELEV 15 RP 1.829 28.75 DECON 347* LEVEL 821119 005143 C30J001 RB DECON-347' ELEV 3 HP 0.455 6.33 DECON 347' LEVEL & ENCLOSED STAIRWELL $821119 005143 C30J001 RB DECON-347' ELEV 10 RP 1.484 19.90 DECON 347' LEVEL & ENCLOSED STAIRWELL

  • 821119 005143 C30J001 RB DECON-347' ELEV 1 CN 0.000 4.27 DECON 347' LEVEL & ENCLOSED STAIRWELL 821129 005196 C30J001 RB DECON-347' ELEV 6 HP 1.072 14.48 DECON 347' LEVEL
  • 821129 005196 C30J001 RB DECON-347* ELEV 26 CN 4.059 53.10 DECON 347' LEVEL 821202 005236 C30J001 R8 DECON-347' ELEV 1 HP 0.160 2.15 DECON 347' LEVEL / REMOTE DECON 282' LEVEL 3821202 005236 C30J001 RB DECON-347' ELEV 13 CN 1.718 22.38 DECON 347' LEVEL / REMOTE DECON 282' LEVEL l

l

i 1 1 [ t I DATE 022486 PAGE 47 PNO 46 .TMI-2 UNC 005 - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. . PERS. DEPT. EXPOS. TIME .CO.D.................................... E. S.CR I P T I O. N E REM . HOURS TASK D .............TYACTIVI........,....... E.NTR I

  • DATE

, NUMB E.R. N UME E. R.... i 821202 005237 C30J001.RB DECON-347' ELEV 2 CN 0.152 2.00 OPEN ELEVATOR 000R - 305' & 347' LEVELS 821213 005305 C30J001 RB DECON-347' ELEV 1 HP n.147 2,07 DECON 347* LEVEL $821213 005305 C30J001 RB DECON-347' ELEV 1 EL o.127 2.00 DECON 347' LEVEL

  • 821213 005305 C30J001 RB DECON-347* ELEV 1 CM 0.159 2.00 DECON 347' LEVEL
  • 821213 005305 C30J001. RB DECON-347' ELEV 1 BS 0.110 2.10 DECON 347' LEVEL
  • 821213 005305 C30J001 RB DECON-347' ELEV 1 IC 0.137 2.15 DECON 347' LEVEL L

821216 005342 C30J001 RB DECON-347* ELEV 1 CM 0.044 0.73 DECON 347' LEVEL

  • 821216 005342 C30J001 RB DECON-347' ELEV 1 OP 0.048 0.77 DECON 347' LEVEL 330118 005604 C30J001 RB DECON-347' ELEV 2 OP 0.296 3.65 DECON ELEVATOR SHAFT & SERVICE STRUCTURE
  • 830118 005604 C30J001 RB DECON-347' ELEV 1 EL 0.154 2.55 DECON ELEVATOR SHAFT & SERVICE STRUCTURE

$330118 005604 C30J001 RB DECON-347* ELEV 1 CM 0.119 2.37 DECON ELEVATOR SHAFT & SERVICE STRUCTURE

  • 830118 005604 C30J001 RB DECON-347' ELEV 1 MM 0.109 2.43 DECON ELEVATOR SHAFT & SERVICE STRUCTURE
  • 830118 005604 C30J001 RB DECON-347' ELEV 1 CN 0.163 2.28 DECON ELEVATOR SHAFT & SERVICE STRUCTURE 830119 005616 C30J001 RB DECON-347' ELEV 2 OP 0.184 3.03 DECON ELEVATOR SHAFT & SERVICE STRUCTURE
  • 830119 005616 C30J001 RB DECON-347' ELEV 1 EL 0.330 2.03 DECON ELEVATOR SHAFT & SERVICE STRUCTURE j
  • S30119 005616 C30J001 RB DECCN-347' ELEV 1 CM 0.110 1.65 DECON ELEVATOR SHAFT & SERVICE STRUCTURE
  • 830119 005616 C30J001 RB DECON-347' ELEV 1 MM 0.338 2.05 DECON ELEVATOR SHAFT & SERVICE STRUCTURE 330628 006824 C30J001 RB DECON-347' ELEV 1 HP 0.221 228.00 DECON TEST SEAL PLATE
  • 830628 006824 C30J001 RB DECON-347' ELEV 6 CN 0.848 9.18 DECON TEST SEAL PLATE a

I 830707 006891 C30J001 RB DECON-347' ELEV 1 HP 0.227 2.28 DECON INCORE INSTRUMENT TABLE 3830707 006891 C30J001 RB DECON-347' E LEV 1 RP 0.157 2.15 DECON INCORE INSTRUMENT TABLE 'd 830707 006891 C30J001 RB DECON-347' ELEV 1 CM 0.166 2.17 DECON INCORE INSTRUMENT TABLE jf**830711006925C30J001RB DECON-347' ELEV 1 MM 0.123 2.03 DECON SEAL TABLE AREA 830711 006925 C30J001 RB DECON-347

  • ELEV 1 CN 0.127 2.07 DECON SEAL TABLE AREA

$30714 006952 C30J001 RB DECON-347' ELEV 1 CN 0.071 1,12 VACUUM BEHIND ELEVATOR SHAFT-347* LEVEL

  • 830714 006952 C30J001 RB DECON-347' ELEV 1 UM 0.078 1.18 VACUUM BEHIND ELEVATOR SHAFT-347' LEVEL 841027 010181 C30J001 RB DECON-347' ELEV 10 OP 0.931 20.02 HANDS ON DECON-347' TO 367* ELEVATIONS 3841027 010181 C30J001 RB DECON-347' ELEV 1 CN 0.095 1.90 HANDS ON DECON-347' TO 367' ELEVATIONS
  • S41027 010181 C30J001 RB DECON-347' ELEV 2 EL 0.216 4.32 HANDS ON DECON-347' TO 367' ELEVATIONS
  • 841027 010181 C30J001 RB DECON-347* ELEV 1 CM 0.051 1,72 HANDS ON DECON-347' TO 367' ELEVATIONS 3841027 010181 C30J001' RB DECON-347' ELEV 1 RP 0.143 2.47 HANDS ON DECON-347TO 367' ELEVATIONS

$841027 010181 C30J001 RB DECON-347' ELEV 2 UM 0.311 3.65 HANDS ON DECON-347' TO 367* ELEVATIONS l } 841106 010239 C30J001 RB DECON-347 ' ELEV 1 UM 0.112 2.20 HANDS ON DECON-RC PUMP MOTOR STAND 2841106 010239 C30J001 RB DECON-347' ELEV 1 CN 0.091 2.18 HANDS ON DECON-RC PUMP MOTOR STAND I 841204 010402 C30J001 RB DECUN-347' ELEV 1 OP 0.050 1.47 ROUTE NLR HOSES FROM 305' TO 347' ELEV f 4

  • 841204 010402 C30J001 RB DECON-347 ' E LEV 1 CN 0.083 1.47 ROUTE NLB HOSES FROM 305' TO 347' ELEV.

] $841204 010402 C30J001 RB DECON-347* ELEV 1 IC 0.101 1.52 ROUTE NLB HOSES FROM 305* TO 347' ELEV 841218 010505 C30J001 RB DECON-347' E LEV 2 RP 0.190 4.25 DECON INCORE INSTRUMENT TABLE

  • 841218 010505 C30J001 RB DECON-347' ELEV 3 OP 0.454 6.77 DECON INCORE INSTRUMENT TABLE I
  • S41218 01050% C30J001 RB DECON-347' ELEV 1 MM 0.144 1.55 DECON INCORE INSTRUMENT TABLE 1

850110 010644 C30J001 RB DECON-347' ELEV 1 RP 0,078 1.90 LOW PRESSURE FLUSH OF INCORE INST. TABLE

  • 850110 010644 C30J001 RB DECON-347
  • ELEV 1 CN 0.123 1.87 LOW PRESSURE FLUSH OF INCORE INST. TABLE 4
  • 850110 010644 C30J001 RB DECON-347' ELEV 1 UM 0.135 1.83 LOW PRESSURE FLUSH OF INCORE INST. TABLE 850111 010651 C30J001 RB DECON-347' ELEV 4 CN 0.288 6.33 WE T VAC/ SCRUB / PAINT-347 ' ELEVATION 850302 011021 C30J001 RB DECON-347' ELEV 4 CN 0.387 9.48 DECON MAIN FH BRIDGE AFTER DISMANTLEMENT 1

850312 011103 C30J001 RB DECON-347' ELEV 2 CN 0.166 4.83 HANDS ON DECON 0F MAIN FH BRIDGE 5 850318 011145 C30J001 RB DECON-347' ELEV 4 CN 0.699 10.52 INSTALL WATER SUPPLY FOR KELLY VAC SYS4 850318 011146 C30J001 RB DECON-347' ELEV 20 CN 2.043 41.22 FLUSH CABLE TRAYS-EAST OF REFUEL CANAL 850321 011182 C30J001 RB DECON-347' ELEV 14 CN 1.065 24.48 EQUIP STAOING/ HOOKUP / EQUIP PROTECTION i C30J001 . SUBTOTAL - EXP TRCK NUMBER = j t } 4 +% wv e g, v g u.- -m. w

l DATE 022486 PAGE 48 PNO. 47 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RwP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ......................RFM........ HOURS..........................CRI.PTION ENTR. CODE TASK DES

  • DATE.. NUMBER. NUMBER,

ACTIVITY 3..... 214 PERS ENTR = 27.145000 EXPOS REM = 649.95000 TIME HOURS .820831 004623 C30L001 DECON RB DOME 2 CN 0.333 4.08 STAGE DECON EQUIPMENT ON POLAR CRANE 820917 004729 C30L001 DECON RB DOME 2 CM 0.304 4.00 DECON R8 DOME FROM POLAR CRANE

  • 820917 004729 C30L001 DECON RB DOME 1 OP 0.142 2.08 DECON RB DOME FROM POLAR CRANE

$320917 004729 C30L001 DECON RB DOME 21#4 0.263 4.37 DECON RB DOME FROM POLAR CRANE

  • 820917 004729 C30L001 DECON RB DOME 4 CN 0.693 9.42 DECON RB COME FROM POLAR CRANE 3820917 004729 C30L001 DECON RB DOME 1 RP 0.119 2.20 DECON RB DOME FROM POLAR CRANE 820926 004783 C30L001 DECON RB DOME 4 RP 0.504 7.82 DECON RB DOME FROM POLAR CRANL 821013 004895 C30L001 DECON RB DOME 9 CN 0.784 18.15 DECON RB DOME FROM POLAR CRANE 821015 004931 C30L001 DECON RB DOME 8 CN 0.984 13.58 PCLAR CRANE PROTECTION
  • 821015 004931 C30L001 DECON RB DOME 2 RP 0.196 2.75 POLAR CRANE PROTECTION

. SUBTOTAL - EXP TRCK NUMBER = C30L001 35 PERS ENTR = . EXPOS REM . 4.3220000 TIME HOURS = 68 450000 .830104 005463 C30M001 DECON SERVICE STRUCT a UM 0.204 1.47 PUNCH HOLES IN NEUTRON SHIELD TANKS 830105 005475 C30M001 DECON SERVICE STRUCT 1 HP 0.161 1.E0 NEUIRON SHIELD TANK HODIFICATIONS

  • 830105 005475 C30M001 DECON SERVICE STRUCT 1 UM 0.247 1.75 NEUTRON SHIELD TANK MODIFICATIONS 830106 005492 C30M001 DECON SERVICE STRUCT 15 CN 1.929 27.80 DECON MISSILE SHIELD DFCON SERVICE STRUCT 6 OP 0.747 12.62 DECON MISSILE SHIELD & SERVICE STRUCTURE

[] *830110 005511 C30M001 830110 005511 C30M001 DECON SERVICE STRUCT 1 IC 0.110 2.73 DECON MISSILE SHIELD & SERVICE STRUCTURE e 830223 005901 C30M301 DECON SERVICE STRUCT 1 EL 0.255 2.37 DECON REFUELING CANAL

  • 830223 005901 C30M001 DECON SERVICE STRUCT 1 OP 0.228 2.50 DECON REFUELING CANAL
  • 830223 005901 C30M001 DECON SERVICE STRUCT 1 UM 0.232 2.33 DECON hEFUELING CANAL 1830223 005901 C30M001 DECON SERVICE STRUCT 1 MM 0.225 2.23 DECON REFUELING CANAL I

830504 006422 C30M001 DECON SERVICE STRUCT 1 OP 0.190 1.77 FLUSH RV STUDS l 3830504 006422 C30M001 DECON SERVICE STRUCT 1 RP 0.140 1.55 FLUSH RV STUDS $830504 006422 C30M001 DECON SERVICE STRUCT 1 IC 0.095 1.78 FLUSH RV STUDS 830505 006432 C30M001 DECOM SERVICE STRUCT 1 HP 0.280 3.00 FLUSH RV STUDS 2830505 006432 C30M001 DECON SERVICE STRUCT 2 OP 0.417 5.23 FLUSH RV STUDS l

  • 830505 006432 C30M001 DECON SERVICE STRUCT 2 IC 0.391 4.87 FLUSH RV STUDS
  • 830505 006432 C30M401 DECON SENv!CE STRUCT 1 EL 0.295 2.40 FLUSH RV STUDS
  • 830505 006432 C30M001 DECON SERVICE STRUCT 1 FN 0.045 1.33 F LUSH RV S TUDS g

830506 006437 C30M001 DECON SERVICE STRUCT 3 OP 0.413 5.55 FLUSH RV STUDS /DECON AIR COOLERS

  • 330506 006437 C30H001 DECON SERVICE STRUCT 2 HP 0.279 3.18 FLUSH RV STUDS /DECON AIR COOLERS
  • 830506 006437 C30M001 DECON SERVICE STRUCT 1 IC 0.052 0.88 FLUSH RV STUDS /DECON AIR COOLERS

$330506 006437 C30Mont DECON SERVICE STRUCT 1 MM 0.234 2.18 FLUSH RV STUDS /DECON AIR COOLERS 330509 006453 C1 DECON SERVICE STRUCT 2 OP 0.246 2.52 FLUSH RV STUDS /DECON AIR COOLERS

  • 830509 006453 C;

. DECON SERVICE STRUCT 1 EL 0.214 1.92 FLUSH RV STUDS /DECON AIR COOLERS

  • 830509 006453 C 3 W na l DECON SERVICE STRUCT 1 MM 0.174 1.95 FLUSH RV STUDS /DECON AIR COOLERS
  • 830509 006453 C30M001 DECON SERVICE STRUCT 1 HP 0.136 2.08 FLUSH RV STUDS /CECON AIR COOLERS
  • 830509 006453 C30M001 DECON SERVICE STRUCT 1 IC 0.231 0.67 FLUSH RV STUDS /DECON AIR COOLERS 830510 006474 C30M001 DECON SERVICE STRUCT 2 HP 0.415 4.65 HP COVERAGE - RV HEAD FLUSH 830815 007214 C30M001 DECON SERVICE STRUCT 1 OP 0.045 1.03 NEUTRON SHIELD TANK REMOVAL
  • 830815 007214 C30M001 DECON SERVICE STRUCT 1 HP 0.020 0.68 NEUTRON SHIELD TANK REMOVAL
  • 830815 007214 C30M001 DECON SERVICE STRUCT 1 RP 0.040 1.02 NEUTRON SHIELD TANK REMOVAL 830815 007219 C30M001 DECON SERVICE STRUCT 2 IC 0.017 3.58 NEUIRON SHIELD TANK REMOVAL
  • 830815 007219 C30M001 DECON SERVICE STRUCT 2 UM 0.017 3.58 NEUIRON SHIELD TANK REMOVAL.

DATE 022486 PAGE 49 PNO. 48 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT EyPOS. TIME.

  • DATE. NUMBER. NUMB
  • .................E.R

............IVITY........... ACT . ENTR.CCDE .kEM ......K DESC.RIPTION TAS . SUBTOTAL - EXP TRCK NUMBER . C30M001. ...................... HOURS...,...... PERS ENTR 61 EXPOS REM 8.8040000 = 115.00000 TIME HOURS = .830315 006056 C30P001 DECON AIR COOLERS 2 HP 0.613 3.72 SURVEY AIR COOLERS & HANDLING UNITS 830316 006069 C30P001 DECON AIR COOLERS I MM 0.027 0.63 REMOTE FLUSH OF AIR COOLERS

  • 330316 006069 C30P001 DECON AIR COOLERS 2 IC 0.067 1.90 REMOTE FLUSH OF AIR COOLERS 3830316 006069 C30P001 DECON AIR COOLERS 1 OP 0.038 1.23 REMOTE FLUSH OF AIR COOLERS 1

830317 006073 C30P001 DECON AIR COOLERS 2 CM 0.143 3.62 DECON AIR COOLERS - 305' LEVEL 3830317 006073 C30P001 DECON AIR COOLERS 3 OP 0.379 5.08 DECON AIR COOLERS - 305' LEVEL

  • 830317 006073 C30P001 DECON AIR COOLERS 1 IC 0.126 2.00 DECON AIR COOLERS - 305' LEVEL 330318 006078 C30P001 DECON AIR COOLERS 2 CM 0.237 4.07 DECON AIR COOLERS 3830318 005078 C30P001 DECON AIR COOLERS 1 UM 0.143 2.33 DECON AIR CCOLERS 3830318 006078 C30P031 DECON AIR COOLERS 3 OP 0.333 5.12 DECON AIR COOLERS 2830318 006078 C30P001 DECON AIR COOLERS I MM 0.096 1.63 DECON AIR COOLERS
  • 830318 006078 C30P301 DECON AIR COOLERS 1 IC 0.132 2.50 DECON AIR COOLERS 830321 006089 C30P001 DECON AIR COOLERS 2 CN 0.355 1.90 DECON AIR COOLERS
  • 830321 006089 C30P031 DECON AIR COOLERS 1 HP 0.006 1.45 DECON AIR COOLERS e

3830321 006089 C30P031 DECON AIR COOLERS 2 OP 0.250 2.62 DECON AIR COOLERS _s 830322 006114 C30P001 DECON AIR COOLERS 1 MM 0.060 1.43 DEC01 AIR COOLERS La *830322 006114 C30P001 DECON AIR COOLERS 1 UM 0.206 1.63 DECON AIR COOLERS PO 8830322 006114 C30P001 DECCN AIR COOLERS 1 OP 0.193 1.63 DECON AIR COOLERS 830325 006136 C30P001 DECON AIR COOLERS 2 HP 0.594 2.40 FLUSH AIR COOLERS 2830325 006136 C30P001 DECON AIR COOLERS 5 CN 1.865 10.96 FLUSH AIR COOLERS

  • 830325 006136 C30P001 DECON AIR COOLERS 1 CM 0.406 1.37 FLUSH AIR COOLERS 3830325 006136 C30P001 DECON AIR COOLERS 1 UM 0.205 1.17 FLUSH AIR COOLERS 3830325 006136 C30P001 DECON AIR COOLERS 1 MM 0.47E 1.30 FLUSH AIR COOLERS 3830325 006136 C30P001 DECON AIR COOLERS 2 OP 0.203 5.50 FLUSH AIR COOLERS 830328 006140 C3CPC01 DECON AIR COOLERS 2 HP 0.326 1.57 FLUSH AIR COOLERS 3830328 006140 C3CPt01 DECON AIR COOLERS 2 OP 0.378 2.48 FLUSH AIR COOLERS 330329 006165 C3CP001 DECON AIR COOLERS 2 OP 0.103 1.33 DECON AIR COOLERS / COVER MANWAY 830329 006174 C30P001 DECON AIR COOLERS 1 RC 0.290 1.33 DECON AIR COOLERS / SWITCH N0ZZLE

$830329 006174 C30Pc01 DECON AIR COOLERS 4 OP 0.497 3.17 DECON AIR COOLERS / SWITCH N0ZZLE 830329 006162 C30P001 DECON AIR COOLERS 1 HP 0.260 1.22 OTSG LEVEL CHECK / SURVEY AIR COOLER 830421 006318 C30P001 DECON AIR COOLERS 1 HP 0.094 2.07 PUMP OUT ELEVATOR SHAFT / PHOTO CLR PANELS

  • S30421 006318 C30P001 DECON AIR COOLERS 1 OP 0.269 1.48 PUMP OUT ELEVATOR SHAFT / PHOTO CLR PANELS 830428 006362 C30PC01 DECON AIR COOLERS 2 UM 0.458 4.77 FLUSH AIR COOLERS / STAGE EQUIPMENT 3830428 006362 C30P001 DECON AIR COOLERS 1 IC 0.160 2.28 FLUSH AIR COOLERS / STAGE EQUIPMENT
  • 830428 006362 C30P001 DECON AIR COOLERS 2 OP 0.242 2.97 FLUSH AIR COOLERS / STAGE EQUIPMENT 8830428 006362 C30P001 DECON AIR COOLERS 1 MM 0.261 2.50 FLUSH AIR COOLERS / STAGE EQUIPMENT 830510 006475 C30P001 DECON AIR COOLERS 2 OP 0.458 4.32 FLUSH RV STUDS AND AIR COOLERS
  • 830510 006475 C30PC01 DECON AIR COOLERS 2 UM 0.331 3.75 FLUSH RV STUDS AND AIR COOLERS
  • 830510 006475 C30PC01 DECON AIR COOLERS 1 IC 0.015 0.47 FLUSH RV STUDS AND AIR COOLERS
  • 130510 006475 C30PC01 DECON AIR COOLERS 2 MM 0.366 3.32 FLUSH RV STUDS AND AIR COOLERS 330512 006485 C30PC01 DECON AIR COOLERS 1 OP 0.037 20.70 CANAL CLEANUP / STAIRWELL FLUSH /CLR DECON
  • 830512 006485 C30POC1 DECON AIR COOLERS 1 IC 0.043 2,07 CANAL CLEANUP / STAIRWELL FLUSH /CLR DECON 830513 006494 C30P0C1 DECON AIR COOLERS 1 UM 0.060 1.77 AIR COOLER DECON/ STAIRWELL FLUSH 8830513 006494 C30P001 DECON AIR COOLERS 1 MM 0.030 1.78 AIR COOLER DECON/ STAIRWELL FLUSH 830516 006504 C30P001 DECON AIR COOLERS 1 OP 0.072 2.60 AIR COOLER DECON 8830516 006504 C30P301 DECON AIR COOLERS 1 MM 0.069 2.48 AIR COOLER DECON

DATE 022486 PAGE 50 PNO. 49 .TMI-2 UNC: CDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0 j

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME l

  • D. AT E... NUMBE R. NUMB.E R.................. T..I V. I T Y.................. ENTR........ C OD E.... R E.M.......H.OURS...........

AC

s..........

830517 006526 C30P001 DECON AIR COOLERS 2 OP 0.160 3.58 AIR COOLER FLUSH

  • 330517 006526 C30P001 DECON AIR COOLERS 1 EL 0.074 1.62 AIR COOLER FLUSH 3830517 006526 C30P001 DECON AIR COOLERS 1 UM 0.086 1.50 AIR COOLER FLUSH 830518 006533 C30P001 DECON AIR COOLERS 1 EL 0.050 0.83 AIR COOLER DECON/DESTAGE HOSES / MOVE SCAF
  • 830518 006533 C30P001 DECON AIR COOLERS 3 CN 1.106 3.73 AIR COOLER DECON/DESTAGE HOSES / MOVE SCAF
  • 830518 006533 C30P001 DECON AIR COOLERS 1 MM 0.055 0.88 AIR COOLER DECON/DESTAGE HOSES / MOVE SCAF 830519 006540 C30P001 DECON AIR COOLERS 1 HP 0.070 1.00 AIR COOLER DECON/ REMOVE COVER / LOWER N0ZZ 2830519 006540 C30P001 DECON AIR COOLERS 1 OP 0.223 2.15 AIR COOLER DECON/ REMOVE COVE R/LOWE R N0ZZ 2830519 006540 C30P001 DECON AIR COOLERS 1 MM 0.150 2.12 AIR COOLER DECON/ REMOVE COVER / LOWER N0ZZ 830520 006551 C30P001 DECON AIR COOLERS 1 OP 0.010 0.42 AIR COOLER FLUSH
  • 830520 006551 C30P001 DECON AIR COOLERS 1 IC 0.015 0.52 AIR COOLER FLUSH
  • 830520 006551 C30P001 DECON AIR COOLERS 2 CN 0.055 1.03 AIR COOLER FLUSH 830523 006565 C30P001 DECON AIR COOLERS 8 CN 0.267 3.70 AIR COOLER DECON 830524 006535 C30P001 DECON AIR COOLERS 2 HP 0.307 1.57 AIR COOLER DECON/ REMOTE FLUSH

$830524 006585 C30P001 DECON AIR COOLERS 23 CN 2.136 16.33 AIR COOLER DECON/ REMOTE FLUSH 830527 006598 C30P001 DECON AIR COOLERS 2 OP 0.057 1.10 AIR COOLER DECON/ REPOSITION LANCE $830527 006598 C30P001 DECON AIR COOLERS 2 IC 0.161 1.45 AIR COOLER DECON/ REPOSITION LANCE $830527 006598 C30P001 DECON AIR COOLERS 2 UM O.048 1.22 AIR COOLER DECON/ REPOSITION LANCE

  • 830527 006598 C30P001 DECON AIR COOLERS 2 MM 0.185 1.37 AIR COOLER DECON/ REPOSITION LANCE 830531 006617 C30P001 DECON AIR COOLERS 2 EL 0.049 0.88 AIR COOLER DECON

-" *S30531 006617 C30P001 DECON AIR COOLERS 6 OP 0.417 3.42 AIR COOLER DECON DECON AIR COOLERS 2 IC 0.123 1.18 AIR COOLER DECON [j **S30531 006617 C30P001 830531 006617 C30P001 DECON AIR COOLERS 4 UM 0.310 2.30 AIR COOLER DECON e

  • 830531 006617 C30P001 DECON AIR COOLERS 2 MM 0.193 1.22 AIR COOLER DECON 830602 006635 C30P001 DECON AIR COOLERS 3 OP 0.272 3.47 STAIRWELL FLUSH / AIR COOLER DECON 8830602 006635 C30P001 DECON AIR COOLERS 1 IC 0.149 2.22 STAIRWELL FLUSH / AIR COOLER DECON 3830602 006635 C30P001 DECON AIR COOLERS 2 UM 0.156 1.33 STAIRWELL FLUSH / AIR COOLER DECON STAIRWELL & LOCA DUCT FLUSH P.C.$39 830614 006722 C30P001 DECON AIR COOLERS 3 CN 0.207 4.43 OPEN SFV-l 830622 006788 C30P001 DECON AIR COOLERS 1 OP 0.000 0.75
  • $30622 006788 C30P001 DECON AIR COOLERS 1 RP 0.000 0.77 OPEN SFV-639 i

l

  • 830622 006788 C30P001 DECON AIR COOLERS 2 HP 0.000 0.97 OPEN SFV-639 830622 006784 C30P001 DECON AIR COOLERS 5 CN 0.596 10.38 LOCA DUCT FLUSH

$830622 006784 C30P001 DECON AIR COOLERS I MM 0.075 1.72 LOCA DUCT FLUSH

  • 830622 006784 C30P001 DECON AIR COOLERS 3 EL 0.172 3.88 LOCA DUCT FLUSH 830705 006860 C30P001 DECON AIR COOLERS 2 CM 0.413 3.18 FLUSH INSIDE AIR COOLERS
  • S30705 006860 C30P001 DECON AIR COOLERS 1 UM 0.326 1.60 FLUSH INSIDE AIR COOLERS 3830705 006860 C30P001 DECON AIR COOLERS 1 CN 0.140 1.73 FLUSH INSIDE AIR COOLERS 840509 008972 C30P001 DECON AIR COOLERS 3 CN 0.645 4.10 DECON INSPECTION l

841204 010399 C30P001 DECON AIR COOLERS 1 RP 0.050 0.60 SAMPLE CONDENSATE 'ASC' AIR COOLER SUMPS 1 CM 0.045 0,45 SAMPLE CONDENSATE 'A&C* AIR COOLER SUMPS l

  • 841204 010399 C30P001 DECON AIR. COOLERS

.SU8 TOTAL - EXP TRCK NUMBER C30P001 177 . PERS ENTR . EXPOS REM = 21.525000 TIME HOURS = 233.82000 l .840412 008808 C35N001 DOSE REDUCTION-P.C. 2 CN 0.106 2.03 MOVE OPERATORS SHIELD BOOTH l . SUBTOTAL - EXP TRCK NUMBER = C35N001 2 PERS ENTR l j EXPOS REM 0.1060000 . TIME HOURS = 2.0300000 821223 005395 C35N002 DOSE REDUCTION-347* 2 OP 0.172 3.20 RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS l I l

.__.m .m_ DATE 022486 PAGE 51 PNO. 50 a .THI-2 UNC-DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ......... E. SC. R I P T I ON TASK D

  • .... E... NUMB E. R. NUMB E R......

...................IVIT.Y....................... CODE...RE.M ...URS

  • DAT ACT ENTR

.HO ............ RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS

  • 821223 005395 C35N002 DOSE REDUCTION-347*

1 IC 0 123 1,43 $821223 005395 C35N002 DOSE REDUCTION-347' 1 HP 0.186 2.17 RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS

  • 821223 005395 C35N002 DOSE REDUCTION-347' 1 CN 0.110 1.55 RAD SURVEY / TRASH REMOVAL / SHIELD DRAINS 831003 007673 C35N002 DOSE REDUCTION-347' 5 CN 0.376 6.23 CLEAN & REMOVE STRIP COAT IN TEST AREA
  • 831003 007673 C35N002 DOSE REDUCTION-347*

1 HP 0.079 1.78 CLEAN & REMOVE STRIP COAT IN TEST AREA 831010 007726 C35N002 DOSE REDUCT10N-347* 1 HP 0.240 1.78 SCABBLE TEST AREA AND SAMPLE

  • 831010 007726 C35N002 DOSE REDUCTION-347*

4 CN 0.335 5.27 SCABBLE TEST AREA AND SAMPLE 831018 007788 C35N002 DOSE REDUCTION-347* 1 HP 0.114 1.38 SCABBLE TEST AREA AND SAMPLE $831018 007788 C35N002 DOSE REDUCTION-347* 2 CN 0.136 2.18 SCABBLE TEST AREA AND SAMPLE 840604 009119 C35N002 DOSE REDUCTION-347' 6 CN 0.430 8.93 ST AGE EQUIP FOR SCABBLING TEST a840604 009119 C35N002 DOSE REDUCTION-347* 1 HP 0.060 0.77 STAGE EQUIP FOR SCABBLING TEST 840605 009133 C35N002 DOSE REDUCT10N-347* 28 CN 2.995 50.68 SCABBLE, CLEAN AND PAINT FLOOR 3840605 009133 C35N002 DOSE REDUCTION-347' 1 HP 0.045 0.67 SCABBLE, CLEAN AND PAINT FLOOR 340608 009155 C35N002 DOSE REDUCTION-347* 1 CN 0.325 1.50 CONTAMINATION CONTROL 2840608 009155 C35N002 DOSE REDUCTION-347* 2 CM 0.216 2.30 CONTAMINATION CONTROL +

  • 840608 009155 C35N002 DOSE REDUCTION-347*

1 IC 0.109 1.40 CONTAMINATION CONTROL 3840608 009155 C35N002 DOSE REDUCTION-347* 1 OP 0.155 1.48 CONTAMINATION CONTROL 840802 009607 C35N002 DOSE REDUCTION-347* 38 CN 4.229 69.82 SET UP EQUIP AND SCABBLE BY STAIRS 840809 009663 C35N002 DOSE REDUCTION-347* 3 CN 0.339 5.43 SCRUB AND PAINT FLOOR 340809 009664 C35N002 DOSE REDUCTION-34 7

  • 14 CN 2.013 16,95 SCABBLE, CLEAN & PAINT NEAR EQUIP HATCH ji 840813 009650 C35N002 DOSE REDUCTION-347' 35 CN 3.776 67.43 SCABBLE, CLEAN & PAINT ca 840815 009704 C35N002 DOSE REDUCTION-347*

4 CN 0.380 6.08 MOVF MATERIALS 45 840820 009729 C35N002 DOSE REDUCTION-347* 22 CN 1.959 40.57 SCA?3LE, WET VACUUM AND PAINT FLOOR e 840827 009777 C35N002 DOSE REDUCTION-347' 8 CN 0.899 14.27 SCAs0LE WE T VACUUM AND PAINT FLOOR 840829 009803 C35N002 DOSE REDUCTION-347' 4 CN 0.182 4.73 MOVE MAiER!ALS AND EQUIPMENT 840829 009804 C35N002 DOSE REDUCTION-347' 12 CN 1.072 21.12 SCABBLE WE T VACUUM AND PAINT FLOOR 840829 009804 C35N002 DOSE REDUCTION-347' 4 CN 0.459 6.80 SCABBLE/ WET VAC & PAINT FLOOR-347' LEVEL 840831 009813 C35N002 DOSE REDUCTION-347' 9 CN 1.711 18.65 MODIFY

  • D*

RING LADDERS 840905 009843 C35N002 DOSE REDUCTION-347' 26 CN 2.552 49.40 SCABBLE/ WET VAC & PAINT FLOOR-347' LEVEL 840913 009895 C35N002 DOSE REDUCTION-347* 14 CN 1.214 32.37 SCABBLE/ WET VAC & PAINT FLOOR-347* LEVEL 840920 009951 C35N002 DOSE REDUCTION-347* 29 CN 2.687 54.37 SCABBLE/ WET VAC & PAINT FLOOR-347' LEVEL 840927 009991 C35N002 DOSE REDUCTION-347* 13 CN 0.874 17.88 STAGE WET VAC/ SCRUB FLOOR & PAINT 840921 009994 C35N002 DOSE REDUCTION-347' 4 CN 0.138 5.37 RELOCATE MISC EQUTPMENT FOR SCABBLING 841004 010039 C35N002 DOSE REDUCTION-347* 2 CN 0.053 1.23 PAINT FLOOR. PUMP STAND & TRIPOD STAND 841121 010333 C35N002 DOSE REDUCTION-347* 5 CN 0.491 8.73 REMOVE SAND BAGS FRDM E AST LOCA DUCT 841128 010360 C35N002 DOSE REDUCTION-347* 22 CN 1.589 41.76 SCABBLE SCRUB. WET VAC & PAIN: FLOOR 841205 010411 C35N002 DOSE REDUCTION-347* 4 CN 0.089 2.60 PAINT FLOOR - 347* ELEVATION 841210 010432 C35N002 DOSE REDUCTION-347* 5 CN 0.727 13.48 RIG SCABBLING DUST TO 305* ELEVATION 841212 010457 C35N002 DOSE REDUCTION-347* 2 CN 0.516 5.23 BAG SCABBLING DUST FOR REMOVAL 350212 010870 C35N002 DOSE REDUCTION-347* 2 CN 0.045 1.10 SHIELD TOP OF RC PUMP MOTOR STAND 850227 010998 C35N002 DOSE REDUCTION-347' S CN 1.018 19.67 INSTALL SHIELDING-INCORE INST. TABLE . SUBTOTAL - EXP TRCK NUMBER . C35N002 PERS ENTR 350 35.218000 EXPOS REM TIME HOURS 619.68000 .830127 005678 C35N003 DOSE REDUCTION-305* 4 RP 0.711 6.77 SHIELDING INSTALLATION 8830127 005678 C35N003 DOSE REDUCTION-305* 3 OP 0.819 6.33 SHIELDING INSTALLATION

  • 830127 005678 C35N003 DOSE REDUCTION-305
  • 1 EL 0.371 1.92 SHIELDING INSTALLATION 3830127 005678 C35N003 DOSE REDUCTION-305
  • 3 MM 0.925 6.10 SHIELDING INSTALLATION
  • 830127 005678 C35N003 DOSE REDUCTION-305*

1 BS 0.065 1.20 SHIELDING INSTALLATION

___.______i _ _ -. _ _ _ _ -. _. _ _ _. _ _ _. _ _ ~ _ _ - - _ _ - ~ ~_ DATE 022486 PAGE 52 PNG 51 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE A
  • ....... NUMBER. NUMBER........CTIVITY.......................ENIR. CODE........ REM........ HOURS.................... TASK D.ESCRIPTION
  • 830127 005678 C35N003 DOSE REDUCTION-305*

2 IC 0.428 3.12 SHIELDING INSTALLATION

  • 830127 005678 C35N003 DOSE R E D UC T I ON -30 5
  • 2 CN 0.468 3.20 SHIELDING INSTALLATION 830201 005714 C35N003 DOSE REDUCTION-305*

5 CN 1.098 13.22 INSTALL SHIELDING SUPP/ INSTALL PLATFORM 430202 005721 C35N003 DOSE REDUCTION-305* 2 CM 0.275 2.23 RESIN COLUMN ELUTION 8830202 005721 C35N003 DOSE REDUCTION-305* 1 HP 0.125 1.20 RESIN COLUMN E LUTION 830203 005732 C35N003 DOSE REDUCTION-305* 5 CN 0.616 3.57 INSTALL SHIELDING SUPP IN OPEN STAIRWELL 830208 005774 C35N003 DOSE R E DUC T ION - 3 0 5

  • 2 CN 0.381 3.35 RESIN COLUMN ELUTION 830217 005855 C35N003 DOSE REDUCTION-305*

4 OP 0 690 7.05 ENCLOSE STAIRWELL / SHIELD STAIRWELL

  • 830217 005855 C35N003 DOSE REDUCTION-305*

1 UM 0.187 1.13 ENCLOSE ST AIRWELL/SHIE LD STAIRWE LL

  • 830217 005855 C35N003 DOSE REDUCTION-305*

2 CN 0.335 2.60 ENCLOSE STAIRWELL / SHIELD STAIRWELL 830309 006017 C35N003 DOSE REDUCTION-305* 4 CN 1.224 10.25 INSTALL PORTABLE SHIELDING DOLLY 830311 006026 C35N003 DOSE REDUCTION-305* 3 CN 0.262 225.00 STAGE MATERIALS 830323 006123 C35N003 DOSE REDUCTION-305* 3 CN 0.828 2.98 INSTALL SHIELD SUPPORT IN OPEN STAIRWELL 830325 006134 C35N003 DOSE R E D UC T I ON-30 5

  • 1 Op 0.173 1,63 SHIELD OPEN STAIRWELL AND HATCH

$830325 006134 C35N003 DOSE REDUCTION-305* 1 '. 0.165 1.60 SHIELD OPEN STAIRWELL AND HATCH 3830325 006134 C35N003 DOSE REDUCTION-305* 1 CM 0.161 1.70 SHIELD OPEN STAIRWELL AND HATCH

  • 830325 006134 C35N003 DOSE REDUCTION-305*

1 MM 0.259 1.55 SHIELD OPEN ST AIRWE LL AND HATCH $830325 006134 C35N003 DOSE REDUCTION-305* 2 IC 0.266 2.92 SHIELD OPEN STAIRWELL AND HATCH 830325 006135 C35N003 DOSE REDUCTION-30$* 4 CN 1.067 3.25 INSTALL SUPPORTS IN OPEN STAIRWELL 830328 006143 C35N003 DOSE REDUCTION-305* 1 EL 0.121 1.15 INSTALL SHIELDING AT COVERED HATCH

  • 830328 006143 C35N003 DOSE REDUCTION-305*

2 CH 0.175 2.18 INSTALL SHIELDING AT COVERED HATCH {j *830328 006143 C35N003 830328 006143 C35N003 DOSE REDUCTION-305* 2 Ft1 0.198 2.25 INSTALL SHIELDING AT COVERED HATCH y, DOSE REDUCTION-305* 1 UM 0.085 1.20 INSTALL SHIELDING AT COVERED HATCH 1 s

  • 830328 006143 C35N003 DOSE REDUCTION-305*

2 IC 0.238 3.17 INiTALL SHIELDING AT COVERED HATCH $30330 006177 C35N003 DOSE REDUCTION-305* 2 OP 0.242 1,18 SHIELD OPEN STAIRWELL /F10SH COOLERS $830330 006177 C35N003 DOSE REDUCT{0N-305* 1 EL 0.055 0.70 SHIE LD OPE N ST AIRWE LL/F LUSH COOLE RS

  • S30330 006177 C35N003 DOSE REDUCTION-305*

1 CM 0.055 0.75 SHIELD OPEN STAIRWELL / FLUSH COOLERS 830405 006218 C35N003 DOSE REDUCTION-305" 1 EL 0.391 1,35 SHIE1D OPEN STAIRWELL / REPLACE PAN TILT

  • 830405 006218 C35N003 DOSE REDUCTION-305*

1 CM 0.210 1.28 SHIELD OPEN ST AIRWELL/REPL ACE PAN TILT 8830405 006218 C35N003 DOSE REDUCT10N-30$* 1 UM 0.242 1.38 SHIE LD OPEN STAIRWE LL/RE PL ACE PAN TILT 8830405 006218 C35N003 DOSE REDUCTION-305* 2 IC 0.614 3.28 SHIE LD OPEN STAIRWE LL/RE PL ACE PAN TILT $830405 006218 C35N003 DOSE REDUCTION-305* 1 OP 0.275 1.38 SHIELD OPEN STAIRWELL / REPLACE PAN TILT 830407 006222 C35N003 DOSE REDUCTION-305* 1 OP 0.045 0.80 INSTALL SHIELDING ON COVERED HATCH

  • 830407 006222 C35N003 DOSE PEDUCTION-305*

1 EL 0.075 0.63 INSTALL SHIELDING ON COVERED HATCH

  • 830407 006222 C35N003 DOSE REDUCTION-305*

1 CM 0.046 0.73 INSTALL SHIE LDING ON COVERED HA TCH 8830407 006222 C35N003 DOSE REDUCTION-305* 1 IC 0.050 0.63 INSTALL SHIELDING ON COVERED HATCH

  • 830407 006222 C35N003 DOSE REDUCTION-305*

1 OP 0.041 0.75 INSTALL SHIELDING ON COVERED HATCH 830415 006275 C35N003 DOSE REDUCTION-305

  • 2 CM 0.196 2.02 SHIELD OPE N 5TAIRWELL WITH LEAD BLANKETS
  • 830415 006275 C35N003 DOSE REDUCTION-305*

1 Fe4 0.123 1.08 SHIELD OPEN STAIRWELL WITH LE AD BLANKETS

  • 830415 006215 C35N003 DOSE REDUCTION-305*

1 IC 0.130 0.93 SHIELD OPEN SIQlRWELL WITH LEAD BLANKETS 830603 006643 C35N003 DOSE REDUCTION-305* 2 RP 0.129 1,90 REMOVE RESIN COLUMN FROM RB 8*0603 006638 C35N003 DOSE REDUCTION-305* 3 RP 0.040 6.45 RECE IVE AND PACKAGE RESIN COLUMN 830610 006688 C35N003 DOSE REDUCTION-305* 2 CN 0.146 1.73 INSTALL SHIELDING AT PENETRATION 252 830722 007023 C35N003 DOSE REDUC TION-305

  • 4 CN 0.558 6,00 SET UP TEMPORARY STORAGE AREA 831212 008075 C15N003 DOSE REDUCTION-305*

1 CN 0.175 2.48 VERIFY AIR LIFT / REMOVE DECON EQUIPMENT 831212 008075 C.5N003 DOSE REDUCTION-305* 1 EL 0.104 1.67 VERIFY AIR LIFT / REMOVE DECON EQUIPiteNT $831282 008075 C35N003 DOSE REDUCT10N-305* 1 CM 0.300 2.38 VERIFY AIR LIFT / REMOVE DECON EQUIPMENT

  • 831212 008075 C35N003 DOSF REDUCTION-305*

1 UM 0.078 1.28 VERIFY AIR LIFT / REMOVE DECON EQUIPMENT

  • 831212 008075 C35N003 DOSE REDUCTION-305*

I MM 0.140 2.03 VERIFY AIR LIfi/ REMOVE DECON EQUIPMENT 840307 008584 C35N003 DOSE REDUCTION-305* I CM 0.240 1.95 REPAIR VACUUMS / REFILL WATER SHIELDS l 1

_ _. _.- =. . _ ~ - _ = DATE 022486 PAGE 53 PNO. 52 i .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. A T E... huMBE.R. NUMBE R.....................IVITY.................

.......C. ODE.... REM............S..............T. ASK D.E.SC R I P T I. ON ACT ENTR . HOUR

  • 840307 008584 C35N003 DOSE REDUCTION-305' 1 CN 0.165 1.97 REPAIR VACUUMS / REFILL WATER SHIELDS 3840307 008584 C35N003 DOSE REDUCTION-305*

1 IC 0.220 1.97 REPAIR VACUUMS / REFILL WATER SHIELDS 840307 008584 C35N003 DOSE REDUCTION-305* 1 CM 0.240 1.95 REPAIR VACUUMS / REFILL WATER SHIELDS

  • 840307 008584 C35N003 DOSE REDUCTION-305' 1 CN 0,165 1.97 REPAIR VACUUMS / REFILL WATER SHIELDS 3840307 008584 C35NC03 DOSE REDUCTION-305' 1 IC 0.220 1.97 REPAIR VACUUMS / REFILL WATER SHIELDS 840418 008853 C35N003 DOSE REDUCTION-305" 4 CN 0.005 18.85 GAMMA SCAN OF CORF BORE SAMPLES 840426 008899 C35N003 DOSE REDUCTION-305" 3 CN 0.211 3.35 REMOVE SOLENOID VA VE AH-V2A 840525 009061 C35N003 DOSE REDUCTION-305*

5 CN 0.000 35.58 GAMMA SCAN OF CONCRETE BORINGS 840808 009657 C35N003 DOSE REDUCTION-305' 1 CN 0.093 0.93 PRE-SCABBLE DATA ACQUISITION 8840808 009657 C35N003 DOSE REDUCTION-305* 1 ES 0.088 0.87 PRE-SCABBLE DATA ACQUISITION 840820 009727 C35N003 DOSE REDUCTION-305' 1 HP 0.025 0.37 PRE-SCABBLE DATA ACQUISITION 841001 010014 C35N003 DOSE REDUCTION-305' 19 CN 4.482 34.57 SCABBLE/ WET VAC/ SCRUB / PAINT FLOOR-305' 341005 010050 C35N003 DOSE REDUCTION-305' 8 CN 0.304 3.87 SCABBLE/ WET VAC/ SCRUB / PAINT FLOOR-305' i 841106 010236 C35N003 DOSE REDUCTION-305' 6 CN 1.666 12.43 INSTALL EQUIPMENT HATCH PLUGS-305' LEVEL 2841106 010236 C35N003 DOSE REDUCTION-305* 1 HP 0.201 1.87 INSTALL EQUIPMENT HATCH PLUGS-305' LEVEL 841213 010467 C35N003 DOSE REDUCTION-305* 61CN 1.095 11.98 INSTALL HATCHES - 305' LEVEL $841213 010467 C35N003 DOSE REDUCTION-305 ' 1 HP 0.260 2.35 INSTALL HATCHES - 305' LEVEL 850116 010682 C35N003 DOSE REDUCTION-305' 6 CN 0.322 5.57 PAINT FLOOR-ZONE 3 AND WEST CATWALK 850122 010724 C35N003 DOSE REDUCTION-305' 22 CN 3.052 50.70 SCABBLE AET VAC/ SCRUB FLOOR ' 850125 010746 C35N003 DOSE REDUCTION-305' 2 CN 0.045 1.30 PAINT FLOOR ARE A IN ZONE 4 DOSE REDUCTION-305' 6 CN 0.183 4.52 PAINT FLOOR AREA IN ZONE 4 $,( 850130 010779 C35N003 850211 010853 C35N003 DOSE REDUCT10N-305' 12 CN 0.630 11.68 BAG SCABBLING DEBRIS /SCABBLE/ PAINT 850220 010940 C35N003 DOSE REDUCTION-305' 3 CN 0.610 4,45 WALKDOWN SHIELD LOCATION FOR RB AIR CLR . SUBTOTAL - EXP TRCK NUMBER . C35N003 214 PERS ENTR = . EXPOS REM 31.698000 . TIME HOURS 585.63000 830415 006277 C35N004 DOSE REDUCTION-232' 3 CN 0.364 4.39 RAISE ELEVATOR MECHANICALLY i

  • 830415 006277 C35N004 DOSE REDUCT ION-2 82
  • 1 HP 0.209 1, 6.1 RAISE ELEVATOR MECHANICALLY

.SUGTOTAL - EXP TRCK NUMBER = C35N004 PERS ENTR. 4 . EXPOS REM = 0.5730000 TIME HOURS. 6.0200000 .830201 005715 C35N005 DOSE REDUCTION-RVHSS 8 CN 1.688 13.87 REMOVE FANS

  • 830201 005715 C35N005 DOSE REDUCTION-RVHSS 2 HP 0.382 3.82 REMOVE FANS 830427 006358 C35N005 DOSE REDUCTION-RVHSS 6 CN 1.578 16.32 INSTALL SCAFFOLD / LOWER SHIELD SUPPORTS
  • 830427 006358 C35N005 DOSE REDUCTION-RVHSS I MM 0.104 2.65 INSTALL SCAFFOLD / LOWER SHIELD SUPPORTS 830428 006364 C35N005 DOSE REDUCTION-RVHSS 13 CN 2.369 30.28 INSTALL SCAFFOLD AND SHIELD SUPPORTS
  • 830428 006364 C35N005 DOSE REDUCTION-RVHSS 2 EL 0.277 4.70 INSTALL SCAFFOLD AND SHIELD SUPPORTS 830830 007354 C35N005 DOSE REDUCTION-RVHSS 4 CN 0.299 5.12 REMOVE SCAFFOLD FROM REFUELING CANAL 830902 007382 C35N005 DOSE REDUCTION-RVHSS 4 CN 0.770 10.18 REMOVE SCAFFOLD FROM REFUELING CANAL
  • 830902 007382 C35N005 DOSE REDUCTION-RVHSS 1 FN 0.131 2.53 REMOVE SCAFFOLD FROM REFUELING CANAL l

. SUBTOTAL - EXP TRCK NUMBER . C35N005 PERS ENTR. 41 . EXPOS REM 7.5980000 TIME HOURS 89.470000 .801016 0B5319 C45H001 RB CORRECTIVE MAINT 1 IC 0.325 0.95 REMOVE SOURCE RANGE PREAMP 801016 085321 C45H001 RB CORRECTIVE MAINT 1 MM 0.200 G.95 REPAIR & EXERCISE ARLK DOOR-EOUIP HATCH 801114 085580 C45H001 RB CORRECTIVE MAINT 2 MM 0.120 3.67 REPAIR, CLEAN, LUBE & TEST INNER DOOR SEALS

  • 801114 085580 C45H001 RB CORRECTIVE MAINT 1 HP 0.040 1.83 REPAIR CLEAN, LUBE & TEST INNER DOOR SEALS

- ~ 1 OATE 022486 PAGE 54 PNO. 53 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. ATE..... NUMBER.NUMBE.R

.............IVITY ............... CODE... REM........ HOURS.........................IPTION ACT . ENTR TASK DESCR 801114 085589 C45H001.RB CORREC11VE MAINT 1 OP 0.000 1.17 REPAIR AND TEST INNER DOOR SEALS 3801114 085589 C45H001 RB CORRECTIVE MAINT 2 CN 0.000 2.50 REPA!R AND TEST INNER DOOR SEALS 3801114 085589 C45H001 RB CORRECTIVE MAINT 2 HP 0.078 2.33 REPAIR AND TEST INNER DOOR SEALS

  • 801114 085589 C45H001 RB CCRRECTIVE MAINT 1 UM 0.005 1.17 REPA!R AND TEST INNER 000R SEALS
  • 801114 085589 C45H001 RB CORRECTIVE MAINT I MM 0.060 1.17 REPAIR AND TEST INNER DOOR SEALS 810203 000287 C45H001 RB CORRECTIVE MAINT 1 IC 0.652 1.18 SOURCE RANGE MONITOR REPAIR 810319 000713 C45H001 RB CORRECTIVE MAINT 1 CN 0.143 0.95 JUMPER LIGHTING CONNECTOR 3810319 000713 C45H001 RB CORRECTIVE MAINT I EL 0.120 0.95 JUMPER LIGHTING CONNECTOR 810625 001347 C45H001 RB CORRECTIVE MAINT 2 IC 0.878 3.67 CCTV REPAIR /GAITRONICS MAINTENANCE 810625 001348 C45H001 RB CORRECTIVE MAINT 2 EL 0.402 1.50 INSTALL PORTABLE LIGHTS IN STAIRWELL 810630 001388 C45H001 RB CORRECTIVE MAINT 2 Fv4 0.018 2.00 REPAIR UNIVERSAL FITTINGS-ARLK INTERLOCK
  • 310630 001388 C45H001 RB CORRECTIVE MAINT 2 CN 0.012 2.00 REPAIR UNIVERSAL FITTINGS-ARLK INIERLOCK 820107 002784 C45H001 RS CORRECTIVE MAINT 1 IC 0.528 2.32 SOURCE RANGE MONITOR TESTING 820204 002961 C45H001 RB CORRECTIVE MAINT 2 CN 0.263 1.57 WALKDOWN FOR FIRE HOSE REPLACEMENT 820216 003046 C45H001 RB CORRECTIVE MAINT 4 CN 0.921 4.97 REPLACE FIRE HOSES / REMOVE OLD HOSES 820225 003126 C45H001 RB CORRECTIVE MAINT 1 OP 0.035 0.92 VENT FIRE SYSTEM HE ADER/LINE UP VALVING l
  • S20225 003126 C45H001 RB CORRECTIVE MAINT 1 HP 0.020 0.92 VENT FIRE SYSTEM HEADER /LINE UP VALVING 820302 003170 C45H001 RB CORRECTIVE MAINT 2 OP 0.206 2.75 FIRE SERVICE SYSTEM OPERATIONS SURVEY
  • 820302 003170 C45H001 RB CORRECTIVE MAINT 1 CN 0.156 1.58 FIRE SERVICE SYSTEM OPERATIONS SURVEY s

820302 003177 C45H001 RB CORRECTIVE MAINT 1 CN 0.005 1,58 OPEN FIRE SYSTEM ISOLATION VALVE

  • 820302 003177 C45H001 RB CORRECTIVE MAINT 1 OP 0.050 1.42 OPEN FIRE SYSTEM ISOLATION VALVE r

OJ 820302 003177 C45H001 RB CORRECTIVE MAINT 1 HP 0.035 1.42 OPEN FIRE SYSTEM ISOLATION VALVE 7 *820510 003804 C45H001 I RB CORRECTIVE MAINT 2 CN 0.351 3.45 MODIFY LIFT RIG l 820623 004134 C45H'01 RB CORRECTIVE MAINT 1 EL 0.467 3.00 PERSONNEL AIRLOCKS MAINTENANCE $820623 004134 C45Ho01 RS CORRECTIVE MAINT 2 MM 0.736 6.08 PERSONNEL AIRLOCKS MAINTENANCE 820706 004221 C45H001 RB CORRECTIVE MAINT 1 HP 0.005 1.25 REPAIR AIR LIMIT SWITCH AND LIGHTS

  • 820706 004221 C45H001 RB CORRECTIVE MAINT 2 EL 0.000 2.33 REPAIR AIR LIMIT SWITCH AND LIGHTS l
  • 820706 004221 C45H001 RB CORRECTIVE MAINT 1 IC 0.000 0.75 REPAIR AIR LIMIT SWITCH AND LIGHTS
  • 820706 004221 C45H001 RB CORRECTIVE MAINT I MD 0.000 1.17 REPAIR AIR LIMIT SWITCH AND LIGHTS 820739 004244 C45H001 RB CORRECTIVE MAINT 2 HP 0.007 9.25 REPLACE DP SWITCH IN PERS ACCESS HATCH
  • 820709 004244 C45H001 RB CORRECTIVE MAINT 2 IC 0.041 6.50 REPLACE DP SWITCH IN PERS ACCESS HATCH
  • 820709 004244 C45H001 RB CORRECTIVE MAINT 1 OP 0.000 6 25 REPLACE DP SWITCH IN PERS ACCESS HATCH 820709 004245 C45H001 RB CORRECTIVE MAINT 2 MM 0.020 4.00 REPLACE DOOR SEAL-EQUIP HATCH OUTER DOOR l

820709 004246 C45H001 RB CORRECTIVE MAINT 1 IC 0.025 3.50 REPLACE DP SWITCHES - EQUIP HATCH ACCESS 820809 004458 C45H001 RB CORRECTIVE MAINT 7 CN 0.005 11.50 REPAIR CONTAMINATION CONTROL CORRIDOR l 820813 004495 C45H001 RB CORRECTIVE MAINT 2 MM 0.286 2.75 MAINTENANCE ADJUSTMENT OF AIRLOCK I 820817 004516 C45H001 RB CORRECTIVE MAINT 2 CN 0.393 3.08 INSTALL WATT METER / REPLACE CAMERA i 320901 004625 C45H001 RB CORRECTIVE Mt!NT 1 MM 0.000 1.00 INSPECT EQUIPMENT AIRLOCK INNER DOOR

  • 820901 004625 C45H001 RB CORRECTIVE MAINT 1 HP 0.008 3.25 INSPECT EQUIPMENT AIRLOCK INNER DOOR
  • 820901 004625 C45H001 RB CORRECTIVE MAINT 1 IC 0.020 2.67 INSPECT EQUIPMENT AIRLOCK INNER DOOR 820903 004644 C45H001 RB CORRECTIVE MAINT 2 MM 0.270 2.33 REPAIR AIRLOCK DOORS 821005 004858 C45H001 RB CORRECTIVE MAINT 3 IC 0.459 6.58 REPAIR TV EQUIPMENT
  • 821005 004858 C45H001 RB CORRECTIVE MAINT 1 RP 0.168 2.07 REPAIR TV EQUIPMENT 821115 005123 C45H001 RB CORRECTIVE MAINT 4 CN 0.002 8.16 MODIFY PENETRATION 561 8821115 005123 C45H001 RB CORRECTIVE MAINT 2 QA 0.000 3.78 MODIFY PENETRATION 561
  • 821115 005123 C45H001 RB COPRECTIVE MAINT 1 HP 0.000 1.07 MODIFV PENETRATION 561 830110 005528 C45H001 RB CORRECTIVE MAINT 2 CN 0.267 3.08 TROUBLESHOOT CAMERA ELECTRICAL PROBLEM 830117 005576 C45H001 RB CORRECTIVE MAINT 4 CN 0.927 7.30 PLUG SERVICE AIR TO ISOLATE 282' ELEV 830310 006020 C45H001 RB CORRECTIVE MAINT 2 MM 0.238 2.48 SURVEY INSIDE AIRLOCK DOORS 830315 006068 C45H001 RB CORRECTIVE MAINT 2 CN 0.114 2.17 REPLACE P.C. TEMPORARY POWER FEED i

l i

DATE 022486 PAGE 55 PNO. 54 .TMI-2 UNC-DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D PERS. DEPT. EXPOS. TIME

  • RWP

.RWP .EXP TRCK. . ENTR. CODE. REM . HOURS TASK DESCRIPTION .NUMCER. NUMBER ACTIVITY

  • DATE ge n u s s e. se m e s s. e s sn es s e, s e a s e m e s o n e ss es semos,sease s.somose, s e ssee, es s e s e, e m e s e s, e m os o s,e s e n e s sa n s a s s e s s e s s e n e s e s m a s s o m m e s s e s s e s 830421 006317 C45H001 RB CORRECTIVE MAINT 1 AD 0.255 1.52 INSTALL FAN PROTECTION / SAFETY INSPECTION
  • 830421 006317 C45H001 RB CORRECTIVE MAINT 1 AM 0.156 1.40 INSTALL FAN PROTECTION / SAFETY INSPECTION 830608 006676 C45H001 RB CORRECTIVE MAINT 6 MM 0.281 12.60 SURVEY CONTAINMENT AND AIRLOCK DOORS 830615 006734 C45H001 RB CORRECTIVE MAINT 3 CN 0.122 3.92 REPAIR PENETRATION R-561 830615 006739 C45H001 RB CORRECTIVE MAINT 9 CN 0.010 16.62 REMOVE PE NE TR ATION FLANGE AND RFTEST
  • 830615 OJ6739 C45H001 RB CORRECTIVE MAINT 1 HP 0,005 6.08 REMOVE PENE TRATION F LANGE AND RETEST 830622 006785 C45H001 RB CORRECTIVE MAINT 12 CN 0.005 23.82 CUT EXISTING LINES / BUILD SCAFFOLD 830628 006825 C45H001 RB CORRECTIVE MAINT 2 CN 0.314 4.13 SNUBBER EVALUATION 831205 008048 C45H001 RB CORRECTIVE MAINT 3 MM 0.150 3.88 OPERABILITY CHECK OF AIRLOCK DOORS 831219 008120 C45H001 RB CORRECTIVE MAINT 2 CN 0.183 3.47 MODIF Y E LEVATOR SHAFT HATCH COVER 831219 008122 C45H001 RB CORRECTIVE MAINT 1 IC 0.121 2.27 ACTIVATE MAGNETIC SWITCH-AIRLOCK DOORS 831227 008157 C45H001 RB CORRECTIVE MAINT 1 IC 0.151 1.85 ACTIVATE AND TEST MAGNETIC SWITCH 840116 008265 C45H001 RB CORRECTIVE MAINT I IC 0.030 1,38 ADJUST MAGNETIC SWITCH-EQUIPMENT HATCH 840116 008258 C45H001 RB CORRECTIVE MAINT 1 MM 0.245 3.50 INSTALL FALL PROTECTION OVER AIR COOLERS 3840116 008258 C45H001 RB CORRECTIVE MAINT 3 CN 0.830 5.00 INSTALL FALL PROTECTION OVER AIR COOLERS 840201 008374 C45H001 RB CORRECTIVE MAINT 2 CN 0.116 2.05 REPLACE DAMAGED AIR HOSE 840227 008527 C45H001 RB CORRECTIVE MAINT 1 QA 0.060 0.68 REMOVE, CABLE MB-531P
  • 840227 008527 C45H001 RB CORRECTIVE MAINT 2 CN 0.240 3.20 REMOVE CABLE MB-531P 840307 008586 C45H001 RB CORRECTIVE MAINT 2 MM 0.118 3.45 AIRLOCK DOOR SURVEILLANCE 840314 008629 C45H001 RB CORRECTIVE MAINT I IC 0.078 1.32 ALIGN MAGNETIC SWITCH-EQUIP HATCH DOOR 840319 008648 C45H001 RB CORRECTIVE MAINT 3 CN 0.670 4.17 CLOSE DAMPERS IN AIR COOLER DUCT a

OJ 840321 008672 C45H001 RB CORRECTIVE MAINT 3 CN 0.542 3.87 CLOSE AIR COOLER DAMPERS a CO 840321 008678 C45H001 RB CORRECTIVE MAINT 2 CN 0.143 1.62 DETERMINE TERMINAL BOX REQUIREMENTS e 840610 009169 C45H001 RB CORRECTIVE MAINT 2 MM 0.095 3.25 MAINTENANCE ON AIRLOCK EQUIPMENT 840808 009655 C45H001 RB CORRECTIVE MAINT 6 CN 0.625 9.74 INSTALL POWER CABLE TERMINAL BOX 840927 009993 C45H001 RB CORRECTIVE ~MAINT 4 EL 0.483 9.95 REPLACE OPERATOR ON AH-V-71 841208 010428 C45H001 RB CORRECTIVE MAINT 2 MM 0.058 2.65 TECH SPEC SURVEILLANCE OF RB DOORS 841213 010470 C45H001 RB CORRECTIVE MAINT 2 EL 0.155 3.37 RE PLACE S0 TEN 0!D OPERATOR ON AH-Y-071

  • 841213 010470 C45H001 RB CORRECTIVE MAINT 1 CN 0.080 2.08 REPLACE SOLENOID OPERATOR ON AH-Y-071 850327 011234 C45H001 RB CORRECTIVE MAINT 2 EL 0.025 1.42 TROUBLESHOOT / REPLACE DREAKER-PDWER BUGGY e C45H001

. SUBTOTAL - EXP TRCK NUMBER = 175 PERS ENTR 16.427000 I EXPOS REM e 302.50000 TIME HOURS = j ,800704 089115 C50H001 RB P.M. AND SURVEY 40 CN 0.027 78.55 EQUIPMENT SURVEILLANCE-AIRLOCKS

  • 800704 0B9115 C50H001 RB P.M. AND SURVEY 4 VI 0.001 9.90 EQUIPMENT SURVEILLANCE-AIRLOCKS 800713 089140 C50H001 RB P.M. AND SURVEY 27 CN 0.044 64.20 EQUIPMENT SURVEILLANCE-AIRLCCKS
  • 800713 089140 C50H001 RB P.M. AND SURVEY 1 VI 0.000 1.92 EQUIPMENT SURVEILLANCE-AIRLOCKS 800716 084170 C50H001 RB P.M. AND SURVEY 1 CN 0.000 1.25 O'ERATE PERSONNEL AIRLOCK 000R

$800716 084170 C50H001 RB P.M. AND SURVEY 1 CR 0.015 0.92 OPERATE PERSONNEL AIRLOCK DOOR

  • 800716 084170 C50H001 RB P,M. AND SURVEY 1 ES 0.018 0.88 OPERATE PERSONNEL AIRLOCK DOOR
  • 800716 084170 C50H001 RB

.M. AND SURVEY 1 VI 0.005 1.75 OPERATE PERSONNEL AIRLOCK DOOR

  • 800716 084170 C50H001 RB P.M.

AND SURVEY 1 HP 0.005 1.25 OPERATE PERSONNEL AIRLOCK DOOR 800716 084175 C50H001 RB P.M. AND SURVEY I CR 0.004 1.33 LEAKRATE TEST AIRLOCK DOORS

  • 800716 084175 C50H001 RB P.M. AND SURVEY 4 CN 0.000 5.89 LEAKRATE TEST AIRLOCK DOORS
  • 800716 084175 C50H001 RB P.M. AND SURVEY I HP 0.000 0.08 LEAKRATE TEST AIRLOCK 000RS 800721 089167 C50H001 RB P.M. AND SURVEY 7 CN 0.012 20.75 EQUIPMENT SURVEILLANCE 800723 084256 C50H001 RB P.M. AND SURVEY 2 CR 0.000 2.58 STAGE EQUIPMENT
  • 800723 084256 C50H001 RB P.M. AND SURVEY 1 HP 0.000 0.75 STAGE EQUIPMENT 800728 089193 C50H001 RB P.M. AND SURVEY 7 CN 0.004 14.27 EQUIPMENT SURVEILLANCE

DATE 021486 PAGE 56 PNO. 55 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME. ....T. ASK D.E S.C R I P T I.ON

  • DATE... NUMBER. NUMBER...................IVITY..................... E. N T R..... CODE... REM........ HOURS................

ACT 800804 099221 C50H001 RB P.M. AND SURVEY 11 CN 0.005 24.25 EQUIPMENT SURVEILLANCE 300806 084489 C50H001 R8 P.M. AND SURVEY 4 CN 0.036 2.72 DECON PERSONNEL HATCH

  • 800806 084489 C50H001 RB P.M. AND SURVEY 5 CR 0.101 4.92 DECON PERSONNEL HATCH
  • 800806 084489 C50H001 R& P.M. AND SURVE Y 1 HP 0.005 1.50 DECON PERSONNEL HAICH 800811 0B9245 C50H001 RB P.M.

AND SURVEY 11 CN 0.003 102.67 EQUIPMENT SURVEILLANCE 801017 085347 C50H001 R8 P.M. AND SURVEY 1 CN 0.020 0.00 LUBE SEAL SURFACE OF INNER AIRLOCK DOOR

  • 801017 085347 C50H001 RB P.M. AND SURVEY 1 MM 0.030 0.67 LUBE SEAL SURFACE OF INNER AIRLOCK DOOR 810317 000692 C50H001 RB P.M. AND SURVEY 1 OP 0.152 1.83 SURVEY 8 VALVES - 305' LEVEL
  • 810317 000692 C50H001 RB P.M.

AND SURVEY I CN 0.099 1.30 SURVEY 8 VALVES - 305' LEVEL 810319 000716 C50H001 RB P.M. AND SURVEY 1 OP 0.075 0.47 SURVEY 13 VALVES - 305* & 347' LEVELS

  • 810319 000716 C50H001 R8 P.M. AND SURVEY I CN 0.075 0.47 SURVEY 13 VALVES - 305* & 347' LEVELS 810528 001148 C50H001 RB P.M. AND SURVEY 1 CN 0.090 1.00 COMPLETE SWS-P-1 INSTALLATION
  • 810528 001148 C50H001 RB P.M.

AND SURVEY I ES 0.332 1.58 COMPLETE SWS-P-1 INSTALLATION

  • 810528 001148 C50H001 RB P.M.

AND SURVEY 1 HP 0.480 1.58 COMPLETE SWS-P-1 INSTALLATION

  • 810528 001148 C50H001 RB P.M.

AND SURVEY 1 VI 0.373 1.58 COMPLETE SWS-P-1 INSTALLATION

  • 810528 001148 C50H001 R8 P.M.

AND SURVEY 1 CR 0.135 1.00 COMPLETE SWS-P-1 INSTALLATION 810528 001149 C50H001 R8 P.M. AND SURVEY 2 EL 0.209 1.83 JUMPER LIGHT PANEL - 347' LEVEL 810528 001150 C50H001 R8 P.M. AND SURVEY 3 IC 0.761 3.33 REPLACE HPR-213 & GAITRONICS

  • 810528 001150 C50H001 R8 P.M.

AND SURVEY 1 HP 0.271 1.08 REPLACE HPR-213 & GAITRONICS 810827 001813 C50H001 RB P.M. AND SURVEY I EL 0.836 1.42 SURVEY AIR COOLER / RIG SAFE TY EQUIP. e

  • 810827 001813 C50H001 RB P.M.

AND SURVEY 1 AD 0.818 1.25 SURVEY AIR COOLER / RIG SAFETY EQUIP.

  • 810827 001813 C50H001 RB P.M.

AND SURVEY 1 CN 0.864 1.33 SURVEY AIR COOLER / RIG SAFETY EQUIP. _s LJ 810924 002038 C50H001 RB P.M. AND SURVEY 2 EL 1.555 2.43 TRO READINGS - AIR COOLER FAN MOTORS uD 811209 002589 C50H001 R8 P.M. AND SURVEY 1 CN 0.256 1.58 TRANSIENT COMBUSTIBLES INVENTCRY ' $811209 002589 C50H001 RB P.M. AND SURVEY 1 ES 0.306 1.57 TRANSIENT COMBUSTIBLES INVENTORY 820105 002764 C50H001 RB P.M. AND SURVEY 1 IC 0.365 1.33 SOURCE RANGE MONITOR TESTING 820114 002823 C50H001 RB P.M. AND SURVEY 1 IC 0.197 0.75 SOURCE RANGE MONITOR TESTING 820126 002896 C50H001 R8 P.M. AND SURVEY 1 IC 0.300 1.33 SOURCE RANGE MONITOR TESTING 820414 003578 C50H001 RB P.M. AND SURVEY 2 MM 0.316 3.50 REPAIR OR REPLACE AIRLOCK SEALS

  • 820414 003578 C50H001 RB P.M.

AND SURVEY 1 CN 0.100 1.75 REPAIR OR REPLACE AIRLOCK SEALS 820415 003590 C50H001 R8 P.M. AND SURVEY 2 CN 0.050 1.67 WALKDOWN NITROGEN BLANKET SYSTEM 820428 003699 C50H001 RB P.M. AND SURVEY 2 OP 0.653 3.17 TEST SMOKE DETECTORS 820428 003700 C50H001 RB P.M. AND SURVEY 1 MD 0.127 2.67 INSPECT AIRLOCK DOORS

  • 820428 003700 C50H001 RB P.M.

AND SURVEY 1 MM 0.124 2.67 INSPECT AIRLOCK 000RS 820526 003951 C50H001 RB P.M. AND SURVEY 2 OP 0.500 3.67 TEST SMOKE DETECTORS 820622 004124 C50H001 RB P.M. AND SURVEY 3 CN 0.411 5.17 SPIDER CHK/ STAGE POWER BUGGY / ADD LIGHTS 820623 004132 C50H001 RB P.M. AND SURVEY 1 CN 0.123 1.58 INSTL ACOUS MONITORS ON CRDM MONIT TUBE

  • 820623 004132 C50H001-R8 P.M.

AND SURVEY 2 IC 0,268 3.17 INSTL ACOUS MONITORS ON CRDM MONIT TUBE 821124 005186 C50H001 RB P.M. AND SURVEY I HP 0.015 2.38 INSTALL RB EXHAUST SAMPLING SYSTEM

  • 821124 005186 C50H001 RB P.M. AND SURVEY 6 CN 0.013 8.02 INSTALL RB EXHAUST SAMPLING SYSTEM 821217 005350 C50H001 RB P,M.

AND SURVEY 2 OP 0.361 2.60 SMOKE DETECTORS FUNCTIONAL TEST 821219 003088 C50H001 R8 P.M. AND SURVEY 2 MM 0.050 2.33 REMOVE SHAFT COUP COV PLATE / ROTATE PUMP

  • 821219 003088 C50H001 RB P.M.

AND SURVEY ! OP 0.015 1.50 REMOVE SHAFT COUP COV PLATE / ROTATE PUMP $821219 003088 C50H001 RB P.M. AND SURVEY 1 CN 0.070 2.50 REMOVE SHAFT COUP COV PLATE / ROTATE PUMP 830421 006314 C50H001 R8 P.M. AND SURVEY 1 IC 0.300 3.05 TEST FIRE SERVICE DETECTORS

  • 830421 006314 C50H001 RB P.M.

AND SURVEY 1 RP 0.184 2.07 TEST FIRE SERVICE DETECTORS 830427 006356 C50H001 RB P.M. AND FURVEY 1 IC 0.240 2.25 TEST FIRE SERVICE DETECTORS

  • 830427 0C6356 C50H001 R8 P.M. AND SURVEY I RP 0.290 2.15 TEST FIRE SERVICE DETECTORS 830512 006487 C50H001 RB P.M.

AND SURbEY 2 IC 0.000 14.48 TRANSFER NEUTRON SOURCE / CALIBRATE INSTS

  • 830512 006487 C50H001 RB P.M. AND SURVEY 2 HP 0.000 1.13 TRANSFER NEUIRON SOURCE /CALIERATE INSTS

DATE 022486 PAGE 57 PNG. 56 .TM!-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE. NUMBER
  • ............. NUMBER

.............ITY ........ CODE,...... REM..............................................................., ACTIV ENTR . HOURS. TASK DESCRIPTION 830519 006557 C50H001 RB P.M. AND SURVEY 1 CN 0.000 3.48 TRANSFER NEUTRON SOURCE TO HOT SHOP

  • 830519 006557 C50H001 RB P.M AND SURVEY 1 HP 0.000 1.58 TRANSFER NEUTRON SOURCE TO HOT SHOP 830520 006550 C50H001 RB P.M.

AND SURVEY 2 OP 0.349 2.43 SMOKE DETECTOR FUNCTIONAL TEST .830524 006588 C50H001 RB P.M. AND SURVEY 2 IC O.000 1.63 TRANSFER NEUTRON SOURCE TO UNIT 1

  • 830524 006588 C50H001 RB P.M. AND SURVEY 1 HP 0.000 1.58 TRANSFER NEUTRON SOURCE TO UNIT 1 830524 006591 C50H001 RB P.M. AND SURVEY 8 CP 1.522 13.57 RE-ROUTE ELECTRIC. WATEP A AIR l!NES 830526 006593 C50H001 RB P.M. AND SURVEY 2 CN 0.460 4.12 PHOTOGRAPHIC SURVEY OF CONTAINMENT 830531 006615 C50H001 RB P.M. AND SURVEY 2 CN 0.072 1.43 PHOTOGRAPHIC SURVEY OF RB 830609 006680 C50H001 RB P.M. AND SURVEY 1 IC 0.164 2.23 DECON 347* LEVEL
  • 830609 006680 C50H001 RB P.M. AND SURVEY 1 UM O.139 2.32 DECON 347' LEVEL

$830609 Oc6680 C50H001 RB P.M. AND SURVEY 1 MM 0.146 2.30 DECON 347' LEVEL

  • 830609 006680 C50H001 RB P,M.

AND SURVE Y 2 CN 0.296 3.23 DECON 347' LEVEL

  • 830609 006680 C50H001 RB P.M.

AND* SURVEY 1 OP 0.162 2.42 DECON 347' LEVEL 830614 006725 C50H001 RB P.M. AND SURVEY 1 CN 0.021 0.70 PHOTO SURVEY OF VALVE SFV-104 830617 006749 C50H001 RB P.M. AND SURVEY 2 CN 0.214 3.68 PHOTO SURVEY OF CONTAINMENT - 347' LEVEL 830623 006792 C50H001 RB P.M. AND SURVEY 6 CN 0.498 10.57 VISUAL & PHOTO INSPECTION OF PENETS 830624 006798 C50H001 RB P.M. AND SURVEY 2 CN 0.083 1.63 PHOTO OF VALVE SFV-104 830629 006837 C50H001 RB P.M. AND SURVEY 2 CN 0.162 3.17 PHOTO SURVEY & INSPECTION OF RB 830707 006898 C50H001 RB P.M. AND SURVEY 2 CN 0.248 4.03 TAG & INSPECT DECON EQUIP.-305' & 347' s 830715 006965 C50H001 RB P.M. AND SURVE Y 1 MM 0.500 1.07 BUILDINO INSPECTION - 305' & 347' LEVELS

  • 830715 006965 C50H001 RB P.M.

AND SURVEY 1 UM 0.102 1.05 BUILDING INSPECTION - 305' & 347' LEVELS -d Sh *830715 006965 C50H001 RB P.M. AND SURVEY 1 RP 0.063 0.98 BUILDING INSPECTION - 305' & 347' LEVELS O 830819 007263 C50H001 RB P.M. AND SURVEY 2 CN 0.031 0.83 PLACE CABINETS FOR COMBUSTIBLE-LIQUID 830930 007604 C50H001 RB P.M. AND SURVEY 2 CN 0.520 4.77 PHOTO SURVEY & CLEANING - ALL LEVELS 831114 007920 C50H001 RB P.M. AND SURVEY 2 IC 0.545 5.38 SMOKE TEST FIRE DETECTCRS - 'D' RINGS 831227 008155 C50H001 RB P.M. AND SURVEY 2 OP 0.625 4.52 FIRE DETECTOR OPERATIONAL CHECK 840123 008307 C50H001 RB P.M. AND SURVEY 1 CN 0.265 1.95 DECON INSPECTION

  • 840123 008307 C50H001 RB P.M. AND SURVEY 1 MM 0.160 1.83 DECON INSPECTION 840201 008380 C50H001 RB P.M.

AND SURVEY 2 CN 0.000 10.18 CABLE TESTING-PENETRATION 534

  • 840201 008380 C50H001 RB P.M. AND SURVEY 10 IC 0.044 17.32 CABLE TESTING-PENETRATION 534 840215 008469 C50H001 RB P.M. AND SURVEY I CN 0.131 1.15 PLACE TLD STRINGS 840803 009615 C50H001 RB P.M.

AND SURVEY 5 CN 0.590 9.38 ELECTRICAL CHECK ON FTS CABLES 840807 009646 C50H001 RB P.M. AND SURVEY 1 MM 0.071 1.57 MOVE TOOLS / STAGE EQUIPMENT

  • 840807 009646 C50H001 RB P.M. AND SURVEY 1 EL 0.084 1.45 MOVE TOOLS / STAGE EQUIPMENT
  • 840807 009646 C50H001 kB P.M. AND SURVEY 1 CN 0.081 1.50 MOVE TOOLS / STAGE EQUIPMENT 840807 009647 C50H001 RB P.M.

AND SURVEY 2 CN 0.156 2.33 REPAIR SCABBLER 840815 009707 C50H001 RB P.M. AND SURVEY 1 OP 0.107 1.57 REMOVE NLB HOSE

  • 840815 009707 C50H001 RB P.M.

AND SURVEY 2 CN 0.225 3.72 REMOVE NLB HOSE 840821 009748 C50H001 RB P.M. AND SURVEY 2 CN 0.156 2.33 GENERAL MAINTENANCE ON SCABBLER UNITS 840828 009795 C50H001 RB P.M. AND SURVEY 2 OP 0.191 3.07 MOVE SAND BAGS

  • 840828 009795 C50H001 RB P.M.

AND SURVEY 1 UM 0.067 1.45 MOVE SAND BAGS

  • 840826 009795 C50H001 RB P.M. AND SURVEY 1 IC 0.092 1.32 MOVE SAND BAGS 840831 009812 C50H001 RB P.M. AND SURVEY 2 CN 0.274 4.63 SLING INSPECTION 840904 009819 C50H001 RB P.M. AND SURVEY 2 CN 0.104 2.45 RELOCATE ED&D TOOL IN RB 840928 010001 C50H001 RB P.M. AND SURVEY 2 OP 0.508 3.75 OPERATIONS SURVEILLANCE 850208 010847 C50H001 RB P.M. AND SURVEY 2 IC 0.140 3.35 CALIBRATION CHECK RC-LT-102 LOOP 850225 010964 C50H001 RB P.M. AND SURVEY 3 CN 0.114 4.93 REBUILD U-5 SCABBLER

. SUBTOTAL - EXP TRCK NUMBER = C50H001 PERS ENTR. 293 EXPOS REM = 23.576000

MTE 022486 PAGE 58 PNO. 57 .TMI-2 UNC: DDT - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE..... E.R. NUMB E R........................................ REM

. NUMB ACTIVITY . ENT4.CUDE .HGURS ................................ E. S. C. R I P T I ON TASK D TIME HOURS 612.45000 .790601 02E243 C70H001 R3 NAD SURVEYS 1 CR 0.012 0.00 GELT SPECTRA THROU7H HATCH DOOR

  • 790601 026243 C70H001 RB RAD SURVEYS 3 CN 0.031 0.00 GELI SPECTRA THROUGo! HATCH DOOR
  • 790601 026243 C70H001 RB RAD SURVEYS 1 VI 0.025 0.00 GELI SPECTRA THROUG4 HATCH DOOR 790605 026589 C70H001 RB RAD SURVEYS 1 CR 0.040 0.00 GELI SPECTRA THROUGH AIRLCCK DOOR
  • 790605 026589 C70H001 RB RAD SURVEYS 5 CN 0.120 0.00 GELI SPECTRA THROUGH AIRLOCK 000R 790606 026590 C70H001 RB RAD SURVEYS 2 CN 0.009 0.00 CELI SPECTRA THROUGH PENETRATION 605
  • 790606 026590 C70H001 RB RAD SURVEYS 1 VI 0.003 0.00 GELI SPECTRA THROUGH PENETRATION 605 790620 015090 C70H001 RB RAD SURVEYS 1 CR 0.004 0.00 GAMt4A RAY SPECTRA IN PENE TRATION 605
  • 190620 015090 C70H001 RB RAD SURVEYS 2 CN 0.008 0.00 GAMMA RAY SPECTRA IN PENETRATION 605
  • 790620 015090 C70H001 RB RAD SURVEYS 1 VI 0.004 0.00 GAMMA RAY SPECTRA IN PENETRATION 605 800723 084255 C70H001 RB RAD SURVEYS 2 CN 0.010 1.75 SPECIAL SURVEY FOR RECOVERY OPERATIONS
  • 800723 084255 C70H001 RB RAD SURVEYS 2 CR 0.225 1.50 SPECIAL SURVE Y FOR RECOVERY OPE RATIONS
  • 800723 084255 C70H001 RB RAD SURVEYS 1 ES 0.220 0.75 SPECIAL SURVEY FOR RECOVERY OPERATIONS
  • 800723 0B4255 C70H001 RB RAD SURVEYS

.1 VI 0.060 0.83 SPECIAL SURVEY FOR RECOVERY OPERATIONS 3800723 084255 C70H001 RB RAD SURVEYS 1 HP 0.000 1.42 SPECIAL SURVEY FOR RECOVERY OPER%TIONS 800815 084611 C70H001 RB RAD SURVEiS 3 CR 0.245 4.58 SPECI AL SURVEY FOR RECOVERY OPERATIONS

  • 800815 084511 C70H001 RB RAD SURVEYS

-1 OP 6.150 C.70 SPECI AL SURVEY FOR RECOVERY OPERATIONS

  • 800815 084611 C70H001 RB RAD SURVEYS S CN b.?O3 9.71 SPECIAL SURVEY FOR RECOVERY OPERATIONS e *800815 084611 C70H001 RB RAD SURVEYS 2 HP 0 002 l'.00 SPECIAL SURVEY f uR RECOVERY OPERATIONS
  • 800815 084611 C70H001 RB RAO SURVEYS 1 ES 0.300 0.78 SPECsAL SURVEY FOR RECOVERY OPERATIONS d

45 821228 005422 C70H001 RB RAD SURVEYS 1 HP 0.161 1.08 HP SURVEY / JOB COVERAGE / TRASH REMOVAL 830110 005507 C70H001 RB RAD SURVEYS 1 HP 0.106 1,42 HP SURVEY / JOB COVERAGE / TRASH REMOVAL 830111 005534 C70H001 RB RAD SURVEYS 1 HP 0.049 1.08 HP SURVEY / JOB COVERAGE /TRa5H REMOVAL 830112 005544 C70H001 RB RAD SURVEYS 2 HP 0.079 0.98 HP SURVEY / JOB CIVERAGEfiRASH REMOVAL 830114 005568 C70H001 RB RAD SURVE?S 1 HP 0.160 1.35 HP SURVEY / JOB COVERAGE /TkASH REMOVAL 830117 005579 C70H001 RB RAD SURVEYS 2 OP 0.250 4.83 TLU5u TOP OF MISSILE SHIELDS

  • 830117 005579 C70H001 RB RAD SURVEYS 2 CM 0.254 4.S5 FLUSH TOP OF MISSILE SHIELDS
  • 83011/ 005579 C70H001 A3 RAD SURVEYS 1 CN 0.163 2.27 FLM M TCP OF MISSILE SHIELD 3
  • 8J0117 005579 M M 01 48 RAD SURVFYS 1 UM 0.090 1.67 FLUSH TOP OF MISSILE SHIELDS 830120 005620'C70H001 RB RAD SURVEYS 1 HP 0.136 0.93 HP SURVEY / JOB COVERAGE 830314 006077 C10H001 R3 RAD SURVEYS 1 HP O.088 1 88 HP SURVEY /0TSG LEVEL CHECK 830321 006088 C70H001 RG RAD SURbEss 1 HP 0.091 1.02 HP SURVEY OF NEUTRON SHIELD /0TSG OHECK 830407 006212 C70H001 RB R AD SURVEYS 3 HP 0.706 8.98 DIRECTIONAL RADIATION SUPVEY OF RR
  • 8304d5 COA 212 C70H001 RB RAD SURVEYS
  • 1 CN 0.202 1.65 DIRECTIONAL RADIATION SURVEY OF RB 830406 006213 C70H001 RB RAD SURViVS 1 HP 0.138 1.07 HP SURVEY / JOB COVERAG0/0TSG CHECK 830415 006278 C70H001 RB RAD SURVEYS 1 HP 0.380 2.18 HP SURVEY / JOB COVERAGE /DTSG CHECK 830415 006279 C70H001 RB RAD SURVEYS 5 HP 1.832 11.58 DIRECTIONAL SURVEY OF CONTAINMENT
  • 830415 006279 C70H001 RB RAD SURVEYS 1 CN 0.438 1.92 DIRECT 1JNAL SURVE Y OF CONTAlhME4T 830421 006315 C70H001 RB RAD SURVEYS 3 HP 0.679 6.07 HP SURVEY / JOB COVERAGE 830427 006354 C70H001 RB PAD SURVEYS 1 HP 0.079 n.88 ROUTINE HP SURVE4 830428 006361 C70H001 RB RAD SURVEYS 2 HP 0.653 5.52 HP SURVEYS / AIR sat 9LE9 830502 006396 C70H001 RB HAD SURVEYS
HP 0.025 1.50 HP SURVEY /J08 COVE 2 AGE 8?0503 006414 C70H001 RB RAD SURVEYS 1 HP 0.085 1.52 HP SURVEY / STRIP COAT & WELDER COVERAGE 830506 006438 C70H001 RB RAD SURVEYS 1 HP 0.130 1.12 HP SURVEY / TRASH REMOVAL 830509 006451 C70H001 RB RAD SURVEYS 1 HP 0.059 0.88 HP SURVEY / AIR SAM?LE/ REMOVE RAP PUMP 830512 006482 C70H001 RB R AD SURVE YS 1 HP 0.143 1,48 HP SURVEY / JOB COVCRAGE 830516 006506 C70H001 RB RAD SURVEYS 1 HP 0.050 0.68 HP SURVEY /0TSG CHECK / JOB COVERAGE 830517 006525 C70H001 RB RAD SURVEYS 1 HP 0 079 1.05 HP SURVEY / NEUTRON SURVEY OF VESSEL 830518 006531 C70H001 RB RAD SURVEYS 1 HP 0.264 175.00 HP SURVEY / AIR SAMPLE / SHIELD SEISMIC GAP N

-e

DATE 022486 PAGE 59 PNO. 58 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .E XP TRCr PERS. DEPT .fxPOS. TIME ....,................D.E.SC R I P T ! 0N TASK

  • DATE.. NUMBER. NUMBER.........

.......c..................... ENTR... CODE... REM........ H O U. R S A tIviTY .RB RAD SURVEYS 1 HP 0.240 1.53 HP SURVEY / AIR SAMPLES 830519 006538 C70H001 830524 006584 C70H001 RB RAD SURVEYS 2 HP 0.118 2.03 JOB LOVER AGE / REMOVE RMS-2 SYSTEM 830531 006616 C70H001 R8 RAD SURVEYS 2 CN 0.197 2.23 HP SURVEY / MISCELLANEOUS JOB COVERAGE

  • 830531 006616 C70H001 RB RAD SURVEYS 9 HP 1.051 13.77 HP SURVEY / MISCELLANEOUS JOB COVERAGE 830608 006673 C70H001 RS RAD SURVEYS 1 CN 0.157 1.63 HP SURVEYS / JOB COVERAGE
  • 830608 006673 C70H001 R8 RAD SURVEYS 4 HP 0.568 4.77 HP SURVEYS /J08 COVERAGE 830620 006759 C70H001 R8 RAD SURVEYS 7 HP 1.075 8.98 HP SURVEYS / JOB COVERAGE 830628 006822 C70H001 RB RAD SURVEYS 5 HP 0.800 6.93 HP SURVEYS / JOB COVERAGE 830711 006911 C70H001 RB RAD SURVEYS 11 HP 1.066 15.97 HP SURVEYS / JOB COVERAGE 830719 006989 C70H001 R8 RAD SURVEYS 7 HP 0.941 11.23 HP SURVEYS / JOB COVERAGE 830725 007033 C70H001 RB RAD SURVEYS 5 HP C.474 6.70 HP SURVEYS / JOB COVE R AGE 830801 007094 C70H001 RB RAD SURVEYS 3 HP 0.311 3.60 HP SURVEYS / JOB COVERAGE 830829 007334 C70H001 R8 RAD SURVEYS 5 HP 0.553 7.38 HP SURVEYS / JOB C0VERACE 830926 007565 C70H001 RB RAD SURVEYS 7 HP 0.900 10.93 HP SURVEYS / JOB COVERAGE 831003 007672 C70H001 RB RAD SURVEYS 1 CN 0.117 1.35 HP SURVEYS / JOB COVERAGE 2831003 007672 C70H001 RB RAD SURVEYS 1 HP 0.248 2.13 HP SURVEYS / JOB COVERAGE 831018 007785 C70H001 R8 RAD SURVEYS 1 CN 0.053 0.58 HP SURVEYS / JOB COVERAGE 3831018 007785 C70H001 RB RAD SURVEYS 2 HP O.494 4.02 HP SURVEYS / JOB COVERAGE 831024 007809 C70H001 RB RAD SURVEYS 3 HP 0.345 3.42 HP SURVEYS / JOB COVERAGE 831031 007843 C70H001 R8 RAD SURVEYS 2 HP 0.504 6.35 HP SURVEYS / JOB COVERAGE e

45 831107 007879 C70H001 R8 RAD SURVEYS 3 HP 0.596 5.20 HP SURVEYS / JOB COVERAGE .s PJ *831107 007879 C70H001 R8 RAD SURVEYS 1 CN 0.056 0.67 HP SURVEYS / JOB COVERAGE e 831114 007918 C70H001 RB RAD SURVEYS 4 HP 0.131 2.58 HP SURVEYS / JOB COVERAGE 831121 007956 C70H001 RB RAD SURVEYS 4 HP 0.819 7.15 HP SURVEYS /JOS COVERAGE 831128 007987 C70H001 R8 RAD SURVEvS 1 HP 0.029 0.83 HP SURVEYS / JOB COVERAGE 831205 008026 C70H001 RB RAD SURVEYS 1 CN 0.017 0.33 HP SURVEYS / JOB COVERAGE 840103 008195 C70H001 RB RAD SURVEYS 1 HP 0.072 1.02 HP SURVEYS / JOB COVERAGE

  • 840103 008195 C70H001 RB RAD SURVEYS 1 CN 0.033 0.73 HP SURVEYS / JOB COVERAGE 840116 008261 C70H001 RB RAD SURVEYS 1 RC 0.024 0.58 HP SURVEYS / JOB COVERAGE
  • 840116 008261 C70H001 R8 RAD SURVEYS 2 HP 0.095 1.92 HP SURVEYS / JOB COVERAGE
  • 840116 008261 C70H001 RB RAD SURVEYS 1 CN 0.160 3.43 HP SURVEYS / JOB COVERAGE 840123 008301 C70H001 RB RAD SURVEYS 1 HP 0.086 1.40 HP SURVEYS / JOB COVERAGE 840130 008347 C70H001 RB RAD SURVEYS 1 CN 0.075 1.82 HP SURVE YS/ JOB COVE R AGE 840201 008378 C70H001 R8 RAD SURVEYS 1 HP 0.049 1.48 HP SURVEYS / JOB COVERAGE 840206 008393 C70H001 RB RAD SURVEYS 2 HP 0.114 1.38 HP SURVE YS/ JOB COVER AGE
  • 840206 008393 C70H001 RB RAD SURVEYS 2 CN 0.134 2.58 HP SURVEYS / JOB COVERAGE 840213 008442 C70H001 RB RAD SURVEYS 3 HP 0,187 4.03 HP SURVEYS / JOB COVERAGE
  • 840213 008442 C70H001 RB RAD SURVEYS 2 CN 0.522 5.73 HP SURVEYS / JOB COVERAGE 840221 008488 C70H001 RB RAD SURVEYS 1 CN 0.100 1.97 HP SURVEYS / JOB COVERAGE

$840221 008488 C70H001 RB RAD SURVEYS 1 HP 0.115 1.83 HP SURVEYS / JOB COVERAGE 840227 008526 C70H001 R8 RAD SURVEYS 4 HP 0.603 6.10 HP SURVEYS / JOB COVERAGE

  • 840227 008526 C70H001 R8 RAD SURVEYS 2 CN 0.050 0.95 HP SURVEYS / JOB COVEPAGE 840305 008561 C70H001 R B R AD SURVEYS 4 HP 0.262 3.72 HP SURVEYS / JOB COVERAGE

$840305 008561 C70H001 RB RAD SURVEYS 1 CN 0.034 0.83 HP SURVEYS / JOB COVERAGE 840312 008599 C70H001 RB RAD SURVEYS 4 HP 0.365 6.73 HP SURVEYS / JOB COVERAGE

  • 840312 008599 C70H001 RB RAD SURVEYS 5 CN 0.327 5.87 HP SURVEYS / JOB COVE RAGE 840319 008649 C70H001 RB RAD SURVEYS 5 HP 0.761 8.18 HP SURVEYS / JOB COVERAGE 840326 008697 C70H001 R8 RAD SURVEYS 2 HP 0.093 1.57 HP SURVEYS / JOB COVERAGE

$840326 008697 C70H001 RB RAD SURVEYS 3 CN 0.303 4.75 HP SURVEYS / JOB COVERAGE 840402 008746 C70H001 RB RAD SURVEYS 1 CN 0,161 2.18 HP SURVEYS / JOB COVERAGE

DATE 022486 PAGE 60 PNO. 59 .THI-2 UNC-DDS - ACTIVITY REPORT-REACTOR BU!! DING DECONTAMINATION 286 D

  • RWP

,RWP .EXP TRCK. PE RS. DEPT. EXPOS. TIME

  • ....... NUMBER. NUMBER......................................... E. N T R....E..PEH........ HOURS.

TASK DESCRIPTIfW . COD

  • DATE ACTIVITY 840409 008781 C70H001 RB RAD SURVEYS 3 HP 0.201 3.17 HP SURVE YS/ JOB COVE R AGE 840416 008828 C70H001 R f1 RAD SURVEYS 3 HP 0.298 2.27 HP SURVE YS/JUtt COVE R AGE

$840416 008828 C70H001 RB R AD SURVE YS 1 CN 0.061 1.82 HP SURVE YS/ JOB COVE R AGE 840423 008862 C70H001 RB RAD SURVE YS 4 HP 0.157 3.23 HP SilRVE YS/ JOB COVE RAGE 840430 008914 C70H001 RB RAD SURVEYS 4 CN 0.150 3.45 HP SdRVEYS/ JOB COVERAGE 840507 008948 C10H001 RB RAD SURVEYS 4 HP 0.254 3.92 HP SURVEYS / JOB COVERAGE

  • 840507 008948 C70H001 RB RAD SURVEYS 1 RP 0.100 1.62 HP SURVE YS/ JOB COVE R AGE

$840507 008948 C10H001 RB RAD SURVEYS 1 CN 0.022 0.68 HP SilRVEYS/ JOB COVERAGE 840514 008993 C70H001 RB RAD SURVEYS 1 HP 0.028 0.58 HP SURVE YS/ JOB COVE R AGE

  • 840514 008993 C70H001 RB RAD SURVEYS 3 CN 0.047 2.05 HP SURVE YS/JDB COVE R AGE 840521 009039 C70H001 RB RAD SURVEYS 3 CN 0.060 2.10 HP SURVE YS/ JOB COVER %GE
  • 840521 009039 C70H001 RB RAD SURVEYS 2 HP 0.!!9 1.70 HP SURVEYS / JOB COVERAGE 840530 009099 C70H001 RD RAD SURVEYS 2 HP 0.176 2.28 HP SURVEYS / JOB COVERAGE 840604 009121 C70H001 RB RAD SURVEYS 5 HP 0.252 3.15 HP SURVE YS/ JOB COVE R AGE

$840604 009121 C70H001 Ril RAD SURVEYS 1 CN 0.018 0.28 HP SURVE YS/Jott COVE R AGE 840610 009168 C70H001 RB RAD SURVE YS 5 CN 0.189 2.82 HP SURVEYS / JOB COVERAGE 840618 009222 C70H001 RB RAD SURVEYS 3 HP 0.038 1.24 HP SURVE YS/ JOB COVE R AGE $840618 009222 C70H001 RB RAD SURVEYS 1 CN 0.030 0.43 HP SURVEYS / JOB COVERAGE 840625 009291 C70H001 RB RAD SURVEYS 4 HP 0.248 3.07 HP SURVEYS / JOB COVERAGE 1 $840625 009291 C70H001 RB RAD SURVEYS 5 CN 0.316 5.22 HP SURVEYS / JOB COVERAGE 840702 009353 C70H001 R8 RAD SURVEYS 3 HP 0.165 2.67 HP SURVEYS / JOB COVERAGE 3w $840702 009353 C70H001 RB RAD SURVEYS 2 CN 0.020 1.17 HP SURVEYS / JOB COVERAGE e 840709 009403 C70H001 RB RAD SUPVEYS 5 HP 0.371 9.30 HP SURVEYS / JOB COVLRAGE $840709 009403 C70H001 RB RAD SURVEYS 4 CN 0.306 2.02 HP SURVEYS / JOB COVERAGE 840716 009454 C70H001 RB RAD SURVEYS 9 HP 0.452 10.05 HP SURVE YS/ JOB COVE R AGE $840716 009454 C70H001 RB RAD SURVEVS 5 CN 0.148 3.77 HP SURVEYS / JOB COVERAGE 840723 009525 C70H001 RB RAD SURVEYS 7 HP 0.421 8.95 HP SURVEYS / JOB COVERAGE

  • 840723 009525 C70H001 RB RAD SURVEYS 1 RC 0.086 1.47 HP SURVE YS/JOR COVERAGE
  • 840723 009525 C70H001 RB RAD SURVEYS 3 CN 0.109 2.65 HP SURVEYS / JOB COVERAGE 840730 009571 C70H001 RB RAD SURVEYS 3 HP 0.140 2.10 HP SURVEYS / JOB COVE R AGE
  • 840730 009571 C70H001 RB RAD SURVEYS 2 CN 0.090 2.35 HP SURVEYS / JOB COVERAGE 840806 009628 C70H001 RB RAD SURVEYS 3 HP 0.282 3.80 HP SURVEYS / JOB COVERAGE

$840806 009628 C70H001 RB RAD SURVEYS 2 CN 0.092 1.18 HP SURVEYS / JOB COVE R AGE 840813 009681 C70H001 RB R AD SURVE YS 1 HP 0.040 0.67 HP SURVE YS/ JOB COVE RAGE

  • 840813 009681 C10H001 RB RAD SURVEYS 4 CN 0.157 3.08 HP SURVEYS / JOB COVERAGE 840820 009726 C10H001 RB RAD SURVEYS 4 HP 0.271 4.37 HP SURVE YS/ JOB COVE R AGE

$840820 009726 C70H001 RB RAD SURVEYS 3 CN 0.102 2.07 HP SilRVE YS/Juif COVE R AGE 840827 009775 C70H001 RB RAD SURVEYS 3 HP 0.205 4.12 HP SURVEYS /JOS COVERAGE

  • 840827 009775 C70H001 RB RAD SURVEYS 5 CN 0.132 5.28 HP SURVEYS / JOB COVERAGE 840904 009818 C70H001 RB RAD SURVEYS 1 CN 0.046 0.70 ROUTINE HP SURVE11 t ANCE & JOB COVER AGE
  • 840904 009818 C70H001 RB RAD SURVEYS 3 HP 0.094 1.75 ROUTINE HP SURVEILLANCE & JOB COVERAGE
  • 840904 009818 C70H001 RD RAD SURVEYS 1 LM 0.040 1.33 ROVIINE HP SURVEILLANCE & JOB C0%ERAGE 840907 009860 C70H001 RB RAD SURVEYS 1 CN 0.090 2.63 TLD STUDY OF LOCA DUCT S & GE NE R AL ARE A

$840907 009860 C70H001 RB RAD SURVEYS 1 OP 0.051 1.15 TLD STUDY OF 10CA DUCTS 1 GE NE R AL ARE A

  • 840907 009860 C70H001 RB RAD SURVEYS 2 HP 0.198 4.00 TLD STUDY OF L OCA DUCT S & Cf NE R AL AREA
  • 840907 009860 C70H001 RB RAD SURVEYS 2 ES 0.182 4.05 TLD STUDY GF LOCA DUCIS & GE NER AL AREA 840910 009865.C70H001 RB RAD SURVEYS 3 CN 0.102 2.05 CRANE & CANAL ROUTINE SURVEY / JOB COV.
  • 840910 009865 C70H001 RB RAD SURVEYS 2 HP 0.035 0,82 CRANE & CANAL ROUTINE SURVE Y/ JOB COV.

840914 009909 C70H001 RB RAD SURVEYS 1 CN 0.072 1.55 11D STUDY UT LOCA DUCTS & GE NER AL ARE A $840914 009909 C70H001 RB RAD SURVEYS 1 OP 0.088 1.47 TLD SIUDY OF LOCA DUCTS & GENERAL ARE A

DATE 022486 PAGE 61 PNO. 60 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPO 3. TIME ACTIVITY ENTR . REM TASK DESCRIPTION

  • DATE... NUMBER. NUMBER.............................................. CODE........ HOURS.........................................................

1 ES 0.073 1.52 TLD STUDY OF LOCA DUCTS & GENERAL AREA

  • 840914 009909 C70H001 RB RAD SURVEYS 340917 009919 C70H001 RB RAD SURVEYS 2 CN 0.089 1.03 CRANE & CANAL R0bTINE SURVEY / JOB COV.
  • 840917 009919 C70H001 RB RAD SURVEYS 4 HP 0.292 6.35 CRANE & CANAL ROUTINE SURVEY / JOB COV.

840924 009965 C70H001 RB RAD SURVEYS 3 CN 0.165 3.24 CRANE & CANAL ROUTINE SURVEY

  • 840924 009965 C70H001 RB RAD SURVEYS 1 HP 0.026 0.53 CRANE & CANAL ROUTINE SURVEY 841001 010013 C70H001 RB RAD SURVEYS 5 HP 0.226 4.22 ROUTINE HP SURVEYS / JOB COVERAGE 841008 010054 C70H001 RB RAD SURVEYS 4 HP 0.512 8.20 ROUTINE HP SURVEYS / JOB COVERAGE 841017 010119 C70H001 RB RAD SURVEYS 1 CN 0.059 1.03 ROUTINE HP SURVEYS / JOB COVE RAGE
  • 841017 010119 C70H001 RB RAD SURVEYS 3 HP 0.145 2.94 ROUTINE HP SURVEYS / JOB COVERAGE 841024 010161 C70H001 RB RAD SURVEYS S HP 0.620 6.40 ROUTINE HP SURVEYS / JOB COVERAGE 841031 101204 C70H001 RB RAD SURVEYS 6 HP 0.187 4.48 ROUTINE HP SURVEYS / JOB COVERAGE 841107 010248 C70H001 RB RAD SURVEYS 1 VI 0.064 1.20 ROUTINE HP SURVEYS / JOB COVERAGE
  • 841107 010248 C70H001 RB RAD SURVEYS 3 HP 0.269 4.07 ROUTINE HP SURVE YS/ JOB COVE RAGE
  • 841107 010248 C70H001 RB RAD SURVEYS 3 CN 0.055 1.62 ROUTINE HP SURVEYS / JOB COVERAGE 841114 010291 C70H001 RB RAD SURVEYS 7 HP 0.572 7.27 ROUTINE HP SURVEYS / JOB COVERAGE 841128 010357 C70H001 RB RAD SURVEYS 4 CN 0.161 2.60 ROUTINE HP SURVEYS / JOB COVERAGE
  • 841128 010357 C70H001 RB RAD SURVEYS 2 HP 0.033 0.97 841205 010414 C70H001 RB RAD SURVEYS 2 CN 0.010 2.37 ROUTINE HP SURVEYS / JOB COVERAGE a 4841205 010414 C70H001 RB RAD SURVEYS 5 HP 0.172 3.78 ROUTINE HP SURVE YS/ JOB COVE R AGE s

841212 010459 C70H001 RB RAD SURVEYS 4 HP 0.230 3.85 ROUTINE HP SURVEYS / JOB COVE RAGE Sh 841219 010515 C70H001 RB RAD SURVEYS 2 HP 0.148 1.92 ROUTINE HP SURVEYS / JOB COVERAGE Sh *841219 010515 C70H001 RB RAD SURVEYS 1 CN 0.036 0.97 ROUTINE HP SURVEYS / JOB COVERAGE 8 841226 010552 C70H001 RB RAD SURVEYS 5 HP 0.330 6.18 ROUTINE HP SURVEYS / JOB COVERAGE 850116 010683 C70H001 RB RAD SURVEYS 3 HP 0.306 5.22 ROUTINE HP SURVEYS / JOB COVE R AGE

  • 850116 010683 C70H001 RB RAD SURVEYS 2 CN 0.033 1.30 ROUTINE HP SURVEYS / JOB COVERAGE 850123 010733 C70H001 RB RAD SURVEYS 5 HP 0.169 3.48 ROUTINE HP SURVEYS / JOB COVERAGE 850130 010775 C70H001 RB RAD SURVEYS 4 HP 0.554 4.35 ROUTINE HP SURVEYS / JOB COVERAGE
  • 850130 010775 C70H001 RB RAD SURVEYS 1 CN 0.028 0.67 ROUTINE HP SURVEYS / JOB COVERAGE 850206 010827 C70H001 RB RAD SURVEYS 5 HP 0.940 6.57 ROUTINE HP SURVEYS / JOB COVERAGE 850213 010816 C70H001 RB RAD SURVEYS 5 HP 0.194 4.68 ROUTINE HP SURVEYS / JOB COVERAGE 850219 010910 C70H001 RB RAD SURVEYS 3 CN 0.042 1.52 ROUTINE HP SURVEYS / JOB COVERAGE
  • 850219 010910 C10H001 RB RAD SURVEYS 1 HP 0.009 0.72 ROUTINE HP SURVEYS / JOB COVERAGE 850225 010960 C70H001 RB RAD SURVEYS 3 CN 0.157 6.97 ROUTINE HP SURVEYS / JOB COVERAGE
  • 850225 010960 C70H001 RB RAD SURVEYS 5 HP 0.117 4.85 ROUTINE HP SURVEYS / JOB COVERAGE 850304 011029 C70H001 RB RAD SURVEYS 3 HP 0.119 2.37 ROUTINE HP SURVEYS / JOB COVERAGE
  • 850304 011029 C70H001 RB RAD SURVEYS 2 CN 0.039 1.40 ROUTINE HP SURVEYS / JOB COVERAGE 850311 011082 C70H001 RB RAD SURVEYS 1 CN 0.008 0.28 ROUTINE HP SURVE YS/ JOB COVERAGE
  • 850311 011082 C70H001 RB RAD SURVEYS 4 HP 0.081 2.08 ROUTINE HP SURVEYS / JOB COVERAGE 850318 011148 C70H001 RB RAD SURVEYS 3 HP 0.086 2.62 ROUTINE HP SURVEYS / JOB COVEPAGE

$850318 011148 C70H001 RB RAD SURVEYS 2 CN 0.062 1.28 ROUTINE HP SURVEYS / JOB COVERAGE 850325 011196 C70H001 RB RAD SURVEYS 4 HP 0.268 5.67 ROUTINE HP SURVEYS / JOB COVERAGE

  • 850325 011196 C70H001 RB RAD SURVEYS 1 CN 0.055 1.00 ROUTINE HP SURVEYS / JOB COVERAGE

. SUBTOTAL - EXP TRCK NUMBER = C70H001 PERS ENTR. 496 EXPOS REM 40.922000 751.25000 TIME HOURS. .820712 004264 C70K002 TLD TREES - 282* 2 CN 0.833 3.92 OPEN FLOOR PENETRATION FOR DECON 820825 004570 C70K002 TLD TREES - 282* 2 CN 0.303 2.45 TLD PLACEMENT BELDW 305' LEVEL . SUBTOTAL - EXP TRCK NUMBER = C70K002 PERS ENTR = 4 _ _ _ _ _ ~ _

DATE 022486 PACE 62 PNO. 61 .TM!-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDINO DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • DATE
  • ....... NUMBER. NUMBER........................Y.......,.............. CODE

............S... TASK DESCRIPTION ACTIVIT . ENTR . REM . HOUR 1.1360000 EXPOS REM TIME HOURS 6.3700000 .830112 005546 C80N001 RB WASTE REMOVAL 3 CN 0.010 3.95 TRASH REMOVAL - 305' LEVEL

  • 830112 005546 C80N001 RB WASTE REMOVAL 1 HP 0.002 1.17 1 RASH ret 40 VAL - 305' LEVEL 830215 005841 C80N001 RB WASTE R E P10V A L 4 RP 0.093 10.91 PACK & TRANSPORT HI RAD TRASH FROM RB 4830215 005841 C80N001 RB WASTE REMOVAL 1 HP 0.028 2.05 PACK & TRANSPORT HI RAD IRASH F ROM RB
  • 830215 005841 C80N001 RB WASTE REMOVAL 2 CN 0.035 5.93 PACK & 1RANSPORT Hi RAD TRASH PROM RB
  • 830215 005841 C80N001 R8 WASTE REMOVAL 1 CM 0.010 2.13 PACK & IRANSPORT HI RAD TRASH FROM RB 830503 006412 C80N001 RB WAS TE REMOVAL 4 CN 0.069 6.35 1 RASH REMOVAL - 305' LEVEL 830503 006413 C80N001 RB WASTE REMOVAL 2 RP 0.239 2.55 STRIP COAT WE1 DER 830504 006416 C80N001 RB WASTE REMOVAL 2 RP 0.013 6.33 PACKAGE HI RAD WELDER 830504 006420 C80N001 RB WASTE REMOVAL 1 HP 0.166 2.37 SURVE Y F OR WE LDE R & TRASH REMOVAL 830504 006426 C80N001 RB WASTE REMOVAL 2 RP 0.044 1.40 WELDER REMOVAL 830509 006452 C80N001 RB WASTE REMOVAL 2 CN 0.040 3.8?

TRASH REMOVAL - 305* LEVEL 830520 006556 C80N001 RB WASTE REMOVAL 2 RP 0.060 3.97 1 RASH RtMOVAL FROM RB $830520 006556 C80N001 RB WASTE REMOVAL 1 OS 0.028 2.57 1R ASH RE140 VAL F R OM R B 4830520 006556 C80N001 RB WASTE REMOVAL 1 UM 0.060 2.57 T R ASH R E MOVA L F R OM R B 830520 006546 C80N001 RB WASTE REMOVAL 2 RP 0.300 3.10 TRASH REMOVAL F ROM RB 830524 006582 C80N001 RB WAST E REMOVAL 4 CN 0.031 4.47 1 RASH REMOVAL F ROM RB 830531 006614 C80N001 RB WASTE REMOVAL 4 CN 0.047 4.70 TR ASH REMOVAL F ROM RB > 830614 006723 C80N001 RB WASTE RENOVAL 1 UM 0.019 1.13 TRASH REMOVAL F ROM SHIELDED ARE A U1 830614 006729 C80N001 RB WASTE REMOVAL 2 RP 0.003 1.18 TRASH REMOVAL FROM ANTEROOM I

  • 830614 006729 C80N001 RB WASTE REMOVAL 1 HP 0.000 0.57 1 RASH RE140 VAL FROM AN TE RDOM 830616 006745 C80N001 RB WASTE REMOVAL 2 RP 0.008 3.25 TRASH REMOVAL FROM ANTERDOM

$830616 006745 C80N001 RB WASTE REMQVAL 1 CN 0.000 0.73 1 RASH REMOVAL F ROM ANTERDOM 8830616 006745 C80N001 RB WASlE REMOVAL 1 OP 0.000 1.17 1R ASH ret 40 VAL F ROM ANT E ROOM

  • 830616 006745 C80N001 RB WASTE REMOVAL 2 UM 0.002 2.35 TRASH REMOVAL FROM ANTEROOM 830620 006758 C80N001 RB WASTE REMOVAL 1 CN 0.009 1.33 ROUTINE TRASH REMOVAL 830629 006836 C80N001 RB WASTE REMOVAL 1 CN 0.042 1.45 ROUT 1HE 1 RASH REMOVAL 830701 006852 C80N001 RB WASTE RE MOVA L 4 CN 0.370 5.65 SE T UP WASTE TRANSFER POINT 830712 006932 C80N001 RB WASTE REMOVAL 3 UM 0.551 4.28 CLEAN UP 305' LEVEL
  • B30712 006932 C80N001 RB WASTE REMOVAL 3 CM 0.499 4.98 CLEAN UP 305' LEVEL 830713 006944 C80N001 RB WASTE REMOVAL 2 RP 0.000 5.17 R E MOVE TRASH FROM PERSONNEL ANTEROOM 9830713 006944 C80N001 RB WASTE REMOVAL 1 CM 0.000 2.53 R E MOVE T R ASH F R OM PE RSONNE L AN T E ROOM
  • 830713 006944 C80N001 RB WASTE REMOVAL 1 MM 0.002 2.57 REMOVE TRASH F ROM PE RSONNE L AN T E R OOM
  • 830713 006944 C80N001 RB WASTE REMOVAL 1 HP 0.000 2.15 REMOVE TRASH FROM PERSONNEL ANTEROOM 830811 007191 C80N001 RB WASTE R E MOVA L 1 IC 0.011 1.58 R E t10VE NtOTRON SHIELD TANKS
  • 830811 007191 C80N001 RB WASTE REMOVAL 1 UM 0.006 1.57 REMOVE NEUTRON SHIE LD T ANKS 830811 007184 C80N001 RB WASTE REMOVAL 2 RP 0.446 3.50 REMOVE NEUIRON SHIE LD T ANKS 830816 007242 C80N001 RB WASTE REMOVAL 2 OP 0.325 3.13 ret 40VE NEUIRON SHIE LD T ANKS

$830816 007242 C80N001 RB WASTE REMOVAL 1 RP 0.233 1.87 REMOVE NEUIRON SHIELD TANKS 830819 007267 C80N001 RB WASTE REMOVAL 1 OP 0.126 1.27 REMOVE NEUIRON SHIE LD TANKS

  • 830819 007267 C80N001 RB WASTE REMOVAL 2 RP 0.185 2.58 REMOVE NEUIRON SHIE LD 1ANKS 830822 007287 C80N001 RB WASIE REMOVAL 3 OP 0.000 0.33 RIMOVE NE UTRON SHIE LD TANKS
  • 830822 007287 C80N001 RB WASTE REMOVAL 1 HP 0.005 1.33 REMOVE NEUTRON SHIELD TANKS
  • 830822 007287 C80N001 RB WASTE REMOVAL 2 RP 0.000 3.01 REMOVE NE UI R ON SHIELD TANKS
  • 830822 007287 C80N001 RB WASTE R E MOVA L 1 MM 0.000 0.87 REMOVE NEUTRON SHIE LD 1 ANKS 830826 007322 C80N001 RB WASTE REMOVAL 2 OP 0.108 2.85 R E MOVE NEUTRON SHIE LD TANKS
  • 830826 007322 C80N001 RB WASTE REMOVAL 2 RP 0.098 2.80 REMOVE NE UIRON SHIELD 1 ANKS
  • 830826 007322 C80N001 R8 WASTE REMOVAL 1 MM 0.005 1.43 REMOVE NEUIRON SHIELD 1ANKS

DATE 022486 PAGE 63 PNO. 62 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME . ENTR . REM . HOURS TASK DESCRIPTION ........ CODE.......................................................................

  • .......huMBER. NUMBER.......................ITY
  • OATE ACTIV................

830829 007353 C80N001 RB WASTE REMOVAL 1 OP 0.005 1.23 HIGH RAD TRASH REMOVAL

  • 830829 007353 C80N001 RB WASTE REMOVAL I UM 0.005 1.17 HIGH RAD TRASH REMOVAL 830829 007335 C80N001 RB WASTE REMOVAL 1 OP 0.005 0.83 HIGH RAD TRASH REMOVAL
  • 830829 007335 C80N001 RB WASTE REMOVAL 1 RW 0.025 0.82 HIGH R AD TR ASH REMOVAL
  • 830829 007335 C80N001 RB WASTE REMOVAL 1 UM 0.015 0.82 HIGH RAD TRASH REMOVAL 830908 007423 C80N001 RB WASTE REMOVAL 4 RP 0.230 6.26 STAGE HIRROR INSULATION / TRASH REMOVAL
  • 830908 007423 C80N001 RB WASTE REMOVAL 1 HP 0.075 1.67 STAGE MIRROR INSULATION / TRASH REMOVAL 830912 007448 C80N001 RB WASTE REMOVAL 2 RP 0.185 2.35 STAGE MIRROR INSULATION / CUT CCNDUIT 830913 0074F4 C80No01 RB WASTE REMOVAL 5 RP 0.668 8.85 REMOVE MIRROR INSULATION FROM kB

$830913 007e74 C80N001 RB WASTE REMOVAL 2 IC 0.125 3.85 REMOVE ltIRROR INSULATION F ROM RB

  • 830913 007474 C80N001 RD WASTE REMOVAL 2 CM 0.068 4.40 REMOVE MIRROR INSULSTION FROM RB 830921 007532 C80N001 RB WASTE REMOVAL 3 OP 0.058 2.08 HIGH RAD T R ASH RE MOVAL 830922 007545 C80N001 RB WASTE REMOVAL 2 OP 0.011 3.12 LOW RAD TRASH REMOVAL
  • 830922 007545 C80N001 RB WASTE REMOVAL 2 EL 0.272 3.55 LOW RAD TRASH REMOVAL

$830922 007545 C80N001 RB WASTE REMOVAL 1 IC 0.012 0.93 LOW RAD TRASH REMOVAL

  • 830922 007545 C80N001 RB WASTE REMOVAL 2 CM 0.209 3.47 LOW RAD TR ASH RE MOVAL 830926 007563 C80N001 RB WASIE REMOVAL 2 RP 0.128 2.70 FEMOVE MIRROR INSULATION FROM RB
  • 830926 007563 C80N001 RB WASTE REMOVAL 1 EL 0.100 1.47 R E MOVE MIRROR INSUL ATION F ROM RB e *830926 007563 C80N001 RB WASTE REMOVAL 1 IC 0.025 1.30 REMOVE MIRROR INSUL Ai!ON F ROM RB

-a 830930 007601 C80N001 RB WASTE REMOVAL 2 CN 0.329 3.11 CUT UP ROLLER DED ASSEMBLIES A 831005 007705 C80N001 RB WASTE REMOVAL 1 MM 0.005 1.70 LOW RAD TRASH RfMOVAL/ SUMP SAMPLE OT *831005 007705 C80N001 RB WASTE REMOVAL 1 RP 0.000 0.55 L OW R AD TR ASH REMOVAL / SUMP ASMPLE 8

  • 831005 007705 C80N001 RB WASTE REMOVAL 1 Ct4 0.005 1.69 LOW RAD TRASH REMOVAL /Sut'P MAMPLE 831005 007702 C80N001 RB WASTE REMOVAL 1 UM 0.018 1.13 LOW RAD TRASH REMOVAL / SUMP SAMPLE A831005 007702 C80N001 RB WASTE REMQVAL 1 EL 0.031 1.15 LOW RAD TR ASH REMOVAL /Sut9 SAMPLE
  • 831005 007702 C80N001 RB WASTE RE MOVAL 1 CN 0.087 1.32 LOW RAD TRASH REMOVAL /SuttP AAMPLE 831014 007763 C80N001 RB WASTE REMOVAL 3 CN 0.254 3.67 SET UP AREA FOR PLASMA ARC
  • 831014 007763 C80N001 RB WASIE REMOVAL 1 MM 0.059 1.05 SEI UP ARE A FOR PLASMA ARC 831018 007789 C80N001 RB WASTE REMOVAL 3 RP 0.047 3.77 CORE OFORIS SAMPLE REF10 VAL 831024 007806 C80N001 RB WASTE REMOVAL 1 IC 0.000 0.88 LOW RAD TRASH REMOVAL
  • 831024 007806 C80N001 RB WASTE REMOVAL 1 OP 0.033 1,02 LOW RAD T R ASH RE MOVAL
  • 831024 007806 C80N001 RB WASTE REMOVAL 1 CM 0.000 0.82 LOW RAD TRASH REMOVAL

$831024 007806 C80N001 RB WASTE REMOVAL 1 UM 0.021 1.02 LOW RAD TRASH REMOVAL 831031 007844 C80N001 RB WASTE REMOVAL 3 OP 0.484 4.56 LOW RAD TR ASH REMOVAL

  • 831031 007844 C80N001 RB WASTE REMOVAL 1 RP 0.025 1.73 LOW RAC TRASH REMOVAL
  • 831031 007844 C80N001 RB WASTE REMOVAL 1 UM 0.020 1.73 LOW RAD TR ASH REMOVAL 831205 008031 C80N001 RB WASTE REMOVAL 1 RP 0.091 1.10 SURVEY OF RB F OR WASTE ~4ANAGEME NT
  • 831205 008031 C80N001 RB WASTE REMOVAL 1 CN 0.090 1.10 SURVEY OF RB FDR WASTE MANAGEMENT 831219 008118 C80N001 RB WASTE REMOVAL 2 RP 0.171 2.07 RE MOVE TR ASH /ST AGE MIRROR INSULATION 840109 008222 C80N001 RB WASTE REMOVAL 1 CM 0.130 1.40 STAGE EQUIPMENT RACKS - 305* LEVEL
  • 840109 008222 C80N001 RB WASTE REMOVAL 1 OP 0.120 1.42 STAGE EQUIPt1ENT RACKS - 305* LEVEL 840109 008225 C80N001 RB WASTE REMOVAL 3 CN 0.687 9.92 CUT UP CONST EQUIP USING PLASMA ARC
  • 840109 008225 C80N001 RB WASTE REMOVAL 1 MM 0.150 2.08 CUT UP CONST EQUIP USING PLASMA ARC 840123 008310 C80N001 RB WASTE REMOVAL 1 RP 0.017 0.74 STAGE HEAD INSULATION RACKS-305' LEVEL

$840123 008310 C80N001 RB WASTE REMOVAL 1 EL 0.014 0.75 STAGE HEAD INSULATION RACKS-305* LEVEL 840130 008352 C80N001 RB WASTE REMOVAL 1 OP 0.054 1.17 SURVEY CONTAINMENT / RAD WASTE INSPECTION

  • 840130 008352 C80N001 RB WASTE REMOVAL 1 RP 0.140 1.95 SURVEY CONT AINME NI/R AD WAST E INSPECTION
  • 840130 008352 C80N001 RB WASTE REMOVAL 1 CN 0.140 1.94 SURVEY CONI AINME NT /R AD WAST E INSPECTION 840206 008400 C80N001 RB WASTE REMOVAL 2 CN 0.209 4.10 CUT AND RE MOVE MISCE LL ANE OUS STEE L 840206 008403 C80N001 RB WASTE REMOVAL 2 CN 0.051 0.92 STAGE MISCELLANCOUS STEEL - 305' LEVEL

DATE 022486 PAGE 64 PNO. 63 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BU11 DING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS.DE PT. EXPOS. TIME

  • DATE. nut 18 E R ACTIVITY ENTR. CODE. REM

. HOURS TASK DESCRIPTION

  • .............NUMBE.R................................,..........................................................................,
  • 84C206 008403 C80N001 RB WASTE REMOVAL 1 EL 0.158 2.67.

STAGE MISCELLANEOUS STEEL - 305' LEVEL $840206 008403 C80N001 RB WAST E RE MOVAL 1 MM 0.134 2.62 STAGE MISCE LL ANE OUS STEE L - 305' LEVEL 840208 008422 C80N001 RB WASTE REMOVAL 1 OP 0.075 1.43 TR ASH AND EQUIPME NT REMOVAL

  • 840208 008422 C80N001 RB WASTE REMOVAL 2 UM 0.091 2.95 TRASH AND EQu!PMENT REMOVAL
  • 840208 008422 C80N001 RB WASTE REMOVAL 1 MM 0.005 1.47 TRASH AND EQUIPMENT R f. MOV A L 840210 008430 C80N001 RB WASTE REMOVAL 1 UM 0.198 2.40 REMOVE MISC STE E L AND R ACKS FROM RB
  • 840210 008430 C80N001 RR WASTE REMOVAL 1 CM 0.015 3.87 REMOVE MISC STEEL AND RACKS FROM RB
  • 840210 008430 C80N001 RB WASTE REMOVAL 1 RP 0.009 1.77 REMOVE MISC SIEE L AND R ACKS F Rott RB

$840210 008430 C80N001 RB WASTE REMOVAL ! MM 0.146 2.45 REMOVE MISC STEEL AND RACKS FROM RB 840314 008626 C80N001 RB WASTE REMOVAL 2 CN 0.302 4.73 EVALUATE CRD CABLE REMOVAL / PREP TRASH

  • 840314 008626 C80N001 RB WASTE REMOVAL 2 RP 0.260 4.62 EVALUAIE CRD CABLE REMOVAL / PRE P TRASH
  • 840314 008626 C80N001 RB WASTE REMOVAL 1 UM 0.115 1.98 EVALUATE CRD CABLE REMOVAL / PREP TRASH 840316 008638 C80N001 RB WASTE R E t40 VAL 2 RP 0.309 3.43 PACKAGE CABLE SAMPLES / REMOVE TRASH
  • 840316 008638 C80N001 RB WASTE REMOVAL 1 UM 0.121 1.75 PACKAGE CAULE SAMPLES / REMOVE TRASH 840319 008645 C80N001 RB WASTE REMOVAL 1 RP 0.109 1.98 R E t10VE !!F STUDS / REMOVE MISC TRASH
  • 840319 008645 C80N001 RB WASTE REMOVAL 1 CM 0.005 2.27 R E MOVE IIF STUDS / REMOVE MISC 1 RASH
  • 840319 008645 C80N001 RR WASTE REMOVAL 1 EL 0.100 2.12 REMOVE !!F STUDS / REMOVE MISC TRASH
  • 840319 008645 C80N001 RB WASTE REMOVAL 1 OP 0.010 2.28 REMOVE 11F STUDS / REMOVE MISC TRASH
  • 840319 008645 C80N001 RB WASTE REMOVAL 1 UM 0.095 1.97 REMOVE IIF STUDS / REMOVE MISC TRASH 8

840322 008682 C80N001 RB WASTE REMOVAL 1 IC 0.015 1.49 REMOVE MISC STEEL AND TRASH - 305* LEVEL M" **840322 008682 C80N001 RB WASTE R E t10VA L 1 EL 0.106 1,47 REMOVE MISC STEE L AND TRASH - 305* LEVEL 840322 008682 C80N001 RB WASTE REMOVAL 1 OP 0.008 1.50 REMOVE MISC STE E L AND TRASH - 305* LEVEL e *840322 008682 C80N001 RB WASTE REMOVAL 1 UM 0.106 1.52 REMOVE MISC STE E L AND TRASH - 305' LEVEL 840328 008720 C80N001 RB WASTE REMOVAL 3 OP 0.286 6.15 REMOVE CORE DEBRIS SAMPLE AND MISC TRASH

  • 840328 008720 C80N001 RB WASIE REMOVAL 1 IC 0.010 2.17 ret 10VE CORE DEBRIS SAMPLE AND MISC TRASH
  • 840328 008720 C80N001 RB WASTE REMOVAL 2 UM 0.307 3.80 REMOVE CORE DEBRIS SAMPLE AND MISC TRASH 840330 008736 C80N001 RB WASTE REMOVAL 2 CN 0.363 5.82 STAGE AND CUT N11ROGEN PIPING

$840330 003736 C80N001 RB WASTE REMOVAL 1 AM 0.050 0.70 STAGE AND CUT NIIROGEN PIPING 840402 008741 C80N001 RB WASTE REMOVAL 1 RP 0.102 1.17 SURVEY RB FOR 1 RASH REMOVAL

  • 840402 008741 C80N001 RB WASTE REMOVAL 1 CN 0.056 0.72 SURVEY RB FOR TRASH REMOVAL 840404 008761 C80N001 RB WASTE REMOVAL 1 MM 0.185 2.35 LOW RAD TRASH R E MOV A1.
  • 840404 008761 C80N001 RO WASTE REMOVAL 1 IC 0.130 2.02 LOW RAD TRASH REMOVAL
  • 840404 008761 C80N001 RB WASTE REMOVAL 1 UM 0.133 2.42 LOW RAD TRASH REMOVAL
  • 840404 008761 C80N001 RB WASTE REMOVAL

,.1 OP 0.113 1.97 LOW RAD TRASH REMOVAL 840409 008784 C80N001 RB WASTE REMOVAL 1 OP 0.031 2.83 REMOVE MISC STE E L AND WOOD

  • 840409 008784 C80N001 RB WASTE R E MOVA1.

1 IC 0.029 2.87 REMOVE MISC S T EE L AND WOOD

  • 840409 008784 C80N001 RB WASTE REMOVAL 1 CM 0.1$9 2.78 fi E MO VE MISC STEEL AND WOOD
  • 840409 008784 C80N001 RB WAsiE REMOVAL 1 UM 0.013 2.78 REMOVE MISC STEEL AND WOOD
  • 840409 008784 C80N001 RB WASTE REMOVAL 1 MM 0.146 2.82 RE MOVE MISC STE E L AND WOOD 840411 008806 C80N001 RB WASTE REMOVAL 5 OP 0.6'12 13.60 HANDLE CRDM DRUMS
  • 840411 008806 C80N001 RB WASTE REMOVAL 1 !C 0.140 2.22 HAND 1E CRDM DMUMS
  • 840411 008806 C80N001 RB WASTE REMOVAL 2 CM 0.339 5.62 HANDLE CRDM DRUMS 840417 008843 C80N001 RB WASTE REMOVAL 1 RP 0.250 1.67 SURVEY RB
  • 840417 008843 C80N001 RB WASTE REMOVAL 1 CN 0.155 1.67

$URVEY RB 840419 008854 C80N001 RB WASTE REMOVAL 1 IC 0.048 0.88 LOW RAD TRASH REMOVAL 840419 008857 C80N001 RB WASTE REMOVAL 2 CN 0.199 3.70 CUT UP PIPE HANGER 840425 008892 C80N001 RB WASTE REMOVAL 1 UM 0.076 0.95 REMOVE TRASH AND DRUMS

  • 840425 008892 C80N001 RB WASTE REMOVAL 1 CM 0.077 0.95 REMOVE TRASH AND DRUMS 840430 008913 C80N001 RB WASTE REMOVAL 1 IC 0.058 2.48 CRDM CAB 1E DRUM REMOVAL
  • 840430 008913 C80N001 RB WASTE REMOVAL 2 CM 0. 0 !I S 5.20 CRDM CABLE DRUM REMOVAL

DATE 022486 PAGE 65 PNO. 64 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME

  • D. A T E.., NUMB. E. R. NU.MBE.R...............IVITY.............................RE.M... HOURS................. E. S C R I P. T I O N ACT ENTR. C OE. E TASK D s.
  • 840430 008913 C80N001 RB WASTE REMOVAL 1 OP 0.015 2.63 CRDM CABLE DRUM REMOVAL 840503 008939 C80N001 RB WASTE REMOVAL 2 RP 0.380 4.25 1R ASH REMOVAL / INSPECT SERVICE STRUCTURE
  • 840503 008939 C80N001 RB WASTE REMOVAL 3 CN 0.531 6.37 TRASH REMOVAL / INSPECT SERVICE STRUCIURE 840509 008971 C80N001 RB WASTE REMOVAL 2 OP 0.125 6.13 REMOVE TRASH AND EQUIPf1ENT
  • 840509 008971 C80N001 RB WASTE RE MOVAL 1 EL 0.007 2.92 REMOVE TRASH AND EQUIPMENT
  • 840509 008971 C80N001 RB WASTE REMOVAL 2 CM 0.153 5.92 REMOVE TR ASH AND EQUIPMENT 840514 008997 C80N001 RB WASTE REMOVAL 3 EL 0.205 3.98 REMOVE AUX MAST AND MISC STEEL

$840514 008997 C80N001 RB WASTE REMOVAL 3 OP 0.588 7.75 REMOVE AUX MAST AND HISC STEEL

  • 840514 008997 C80N001 RB WASTE REMOVAL 2 UM 0.024 4.35 REMOVE AUX MAST AND MISC STEEL
  • 840514 008997 C80N001 RB WASTE REMOVAL 2 CM 0.180 5.72 REMOVE AUX MAST AND HISC STEEL 840517 009022 C80N001 RB WASTE REMOVAL 1 CN 0.059 1.22 EMP!Y VACUUM COLLECTION DRUMS - CANAL
  • 840517 0090.'2 C80N001 RB WAST E REl-10 VAL 1 UM 0.077 1.22 EMPTY VACUUM COLLECTION DRUMS - CANAL
  • 840517 009022 C80N001 RB WASTE REMOVAL 1 OP 0.060 1.18 E MPTY VACUUM COL LE CT ION DRUMS - CANAL 840523 009064 C80N001 RB WASTE REMOVAL 1 CM 0.152 1,55 LOAD CONUUCTOR CARS AND TRASH
  • 840523 009064 C80N001 RB WASTE REMOVAL 1 IC 0.163 1.58 E0A0 CONDUCTOR BARS AND TRASH
  • 840523 009064 C80N001 RB WASTE REMOVAL 1 CN 0.053 0.82 LOAD CONDUCIUR BARS AND TRASH
  • 840523 009064 C80N001 RB WASTE REMOVAL 1 RP 0.051 0.78 LOAD CONDUCTOR BARS AND TRASH 840525 009073 C80N001 RB WASTE REMOVAL 2 RP 0.013 4.53 REMOVE AF HB WAST E s
  • 840525 009073 C80N001 RB WASTE REMOVAL 2 OP 0.569 3.80 REMOVE AFHB WASTE d
  • 840525 009073 C80N001 RB WASTE REMOVAL 1 EL 0.135 1.90 REMOVE'AFHB WA$iE
    • *840525 009073 C80N001 RB WASTE REMOVAL 2 CM 0,019 4.10 REMOVE AFH8 WASTE G *840525 009073 C80N001 RB WASTE REMOVAL 1 IC 0.142 1.89 RE MOVE AF HB WAS TE 840607 009149 C80N001 RB WASTE REMOVAL 1 RP 0.205 2.28 1R ASH AND EQUIPME NT REMOVAL
  • 840607 009149 C80N001 RB WASTE REMOVAL 1 OP 0.016 2.13 TRASH AND E QUIPME N T REMOVAL

$840G07 009149 C80N001 RB WASTE REMOVAL 1 IC 0.230 2.32 1 RASH AND E0u!PME NT REMOVAL

  • 840607 009149 C80N001 RB WASTE REMOVAL 1 CM 0.015 1.93 TRASH AND EQUIPME NT REMOVAL 840621 009261 C80N001 RB WASTE REMOVAL 1 RP 0.133 1.52 RB TRASH INSPEC110N
  • 840621 009261 C80N001 RB WASTE REMOVAL "I CN 0.128 1.47 RB TRASH INSPECTION 840626 009310 C80N001 RB WASTE REMOVAL 2 RP 0.020 3.73 REMOVE MISC STEEL
  • 840626 009310 C80N001 RB WASTE REMOVAL 2 OP 0.270 3.82 REMOVE MISC STEE L 840627 009324 C80N001 RB WASTE REMOVAL 1 OP 0.096 0.95 REMOVE MISC STE E L
  • 840627 009324 C80N001 RB WASTE REMOVAL 1 IC 0.100 1.80 RE MOVE MISC S TE E L
  • 840627 009324 C80N001 RB WASTE REMOVAL 1 RP 0.034 0.85 RE MOVE MISC STE E L
  • 840627 009324 C80N001 RB WASTE REMOVAL 1 EL 0.116 1.80 REMOVE MISC SIEEL 840628 009330 C80N001 RB WASTE REMOVAL 2 OP 0.165 2.30 REMOVE TRASH /CRDM CLOSURES 840703 009370 C80N001 RB WASTE REMOVAL 2 RP 0.375 3.47 RB TRASH INSPECTION
  • 840703 009370 C80N001 RB WASTE REMOVAL 1 CN 0.200 1.77 RB TRASU INSPECTION 840703 009372 C80N001 RB WASTE REMOVAL 2 CN 0.230 2.62 CUT UP MISC STEEL 840706 009388 C80N001 RB WASTE REMOVAL 1 IC 0.006 1.42 RB TRASH REMOVAL
  • 840706 009388 C80N001 RB WASTE REMOVAL 2 RP 0.160 3.08 RB TRASH REMOVAL
  • 840706 009388 C80N001 RB WASTE REMOVAL 1 OP 0.139 1.80 RB TRASH REMOVAL
  • 840706 009388 C80N001 RB WASTE REMOVAL 1 CN 0.190 1.82 RB TRASH REMOVAL

$40711 009427 C80N001 RB WASTE REMOVAL 2 OP 0.512 4.83 RB TRASH REMOVAL

  • 840711 009427 C80N001 RB WASTE REMOVAL 2 RP 0.022 4.48 RB TR ASH REMOVAL 840713 009446 C80N001 RB WASTE REMOVAL 2 RP 0.020 2.83 RB TRASH REMOVAL
  • 840713 009446 C80N001 RB WASTE REMOVAL 2 OP 0.300 2.97 RB TRASH REMOVAL
  • 840713 009446 C80N001 RB WASTE REMOVAL 1 CN 0.175 1.55 RB TRASH REMOVAL 840717 009479 C80N001 RB WASTE REMOVAL 1 RP 0.017 0.60 RB 1 RASH REMOVAL 840731 009595 C80N001 RB WASTE RE MOVAL 4 CM 0.363 8.00 RB TRASH INSPECTION
  • 840731 009595 C80N001 RB WASTE REMOVAL 3 RP 0.217 2.60 RB 1 RASH INSPECTION

DATE 022486 PAGE 66 PNO. 65 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ACTIVITY ENTR.CDDE . REM TASK DESCRIPTION

  • DATE
  • ....... NUMBER. NUMBER

........ HOURS

  • 840731 009595 C80N001 RB WASTE REMOVAL 1 CN 0.064 0.83.

.RB TRASH INSPECTION 840814 009706 C80N001 RB WASTE RE MOVAL 6 CN 0.589 6.02 REMOVE HIGH RE ACH F ROM RB 840817 009717 C80N001 RB WASTE REMOVAL 2 RP 0.050 1.90 LOW RAD IRASH RE MOVAL

  • 840817 009717 C80N001 RB WASTE REMOVAL 1 CN 0.000 2.33 LOW RAD TRASH REMOVAL 840822 009754 C80N001 RB WASTE RE MOVAL 2 MM 0.289 5.02 REMOVE E QUI PME N T

$840822 009754 C80N001 RB WASTE REMOVAL 3 OP 0.477 6.37 REMOVE EQUIPMENT

  • 840822 009754 C8SN001 RB WASTE RFSt0 VAL 1 IC 0.095 1.33 REMOVE EQUIPME N T
  • 840822 009754 C80N001 RB WASTE RE 40 VAL 2 CM 0.227 3.81 REMOVE EQUIPt1ENT 840822 009755 C80N001 R8 WASTE R E Nt0VA L 4 CN 0.541 8.85 LOWER PENDANIS & TURNBUCKLES TO 305'ELEV 840824 009767 C80N001 R8 WASTE REs10 VAL 2 RP 0.307 4.22 1 RASH REMOVAL / INSPECTION
  • 840824 009767 C80N001 Ril WASTE RE MOVAL 1 MM 0.165 1.95 TR ASH ret 10 VAL / INSPECTION 840828 009194 C80N001 R8 WASTE RE10 VAL 2 Hi 0.085 2.18 UNLOAD SK!P PAN / LOAD SCRAP IN WOOD BOXES
  • 840828 009794 C80N001 RB WASIE RE 40 VAL 3 OP 0.355 7.00 UNLOAD SKIP PAN / LOAD SCRAP IN WOOD BOXE S
  • 840828 009794 C80N001 RB WASTE RE:40VA L 2 IC 0.248 5.08 UNIDAD SKIP PAN / LOAD SCRAP IN WOOD BOXES

$840828 009794 C80N001 RB WASTE R E r10VA L 1 RP 0.015 2.63 UNLOAD SKIP PAN / LOAD SCRAP IN WOOD BOXES

  • 840828 009194 C80N001 RB WASTE R E o10VA L 1 GM 0.007 2.63 UNLOAD SKIP PAN / LOAD SCRAP IN WOOD BOXES 840905 009842 C80N001 RB WASTE R E h10 VAL 2 OP 0.151 4.80 REMOVE SCR AP F ROM RD RB WASTE REMOVAL 1 MM 0.011 2.25 RE MOVE SCR AP F ROM RB

[.,, $840905 009842 C80N001

  • 840905 009842 C80N001 R8 WASTE REMOVAL 1 CM 0.141 2.52 REMOVE SCR AP FR0f t RB a

840906 009849 C80N001 RB WASTE REMnVAL 2 MM 0.000 2.25 REMOVE TR ASH F ROtt R8 m *840906 009849 C80N001 RB WASTE REMOVAL 1 CM 0.035 1.23 REMOVE TR ASH F ROM RB e 840901 009854 C80N001 RB WASTE REMOVAL 1 RP 0.140 1,42 INSPECTIONS-ALL ELEVATIONS 840913 009906 C80N001 RB WASTE REMOVAL 3 MM 0.015 4.13 REMOVE SAND FROM RB

  • 840913 009906 C80N001 R8 WASTE REMOVAL 4 OP 0.014 6.43 REMOVE SAND FROM RB
  • 840913 009906 C80N001 RB WASTE REMOVAL 1 CM 0.003 2.15 REMOVE SAND FROM RB 840918 009935 C80N001 RB WAST E RE110 VAL 1 EL 0.350 2.25 REBAG BROKE N BAGS / REMOVE FROM RB
  • 840918 009935 C80N001 RB WASTE REMOVAL 1 MM O.315 2.22 REBAG BROKE N BAGS / REMOVE F NOH RB
  • 840918 009935 C80N001 RB WASTE REMOVAL 1 OP 0.439 2.12 REBAG BROKEN BAGS /RIMOVE FROM RB
  • 840918 009935 C80N001 RB WASTE REMOVAL 1 CM 0.496 2.12 Rf CAG BROKEN BAGS / REMOVE FROM RB 840920 009952 C80N001 RB WASTE R E l10VA L 2 RP 0.458 3.98 INSPECTION / BAG TRASH AND SAND 841004 010038 C80N001 RB WASTE REMOVAL 1 RP 0.020 0.53 REMOVE TR ASH F R0t4 RB

$841004 010038 C80N001 RB WASIE R El10VA L 1 EL 0.015 0.53 REMOVE TRASH FR0tt RB 841011 010084 C80N001 RB WASTE REf10 VAL 1 CN 0.000 2.55 RE MOVE SAND AND WATER COLUMNS / INSPECTION

  • 841011 010084 C80N001 RB WASTE R E l10VA L 1 OP 0.110 1.92 REMOVE SAND AND WATER C OL UMNS/ I N'iPE C T I ON
  • 841011 010084 C80N001 RB WASTE RE110 VAL 1 RP 0.130 1.93 REMOVE SAND AND WAT E R COLUMNS /INSPE CT ION
  • 841011 010084 C80N001 R8 WASTE R E l10VA L 1 UM 0.096 1.87 REMOVE SAND AND WATER COLUMNS / INSPECTION
  • 841011 010084 C80N001 RB WASTE R E f10VA L 1 MM 0.088 1.60 R E MOVE SAND AND WA TE R COLUMNS / INSPECTION 841017 010116 C80N001 RB WASTE R E l10VA L 2 OP 0.139 3.25 REMOVE CUT UP WATER COLUMNS 841022 010136 C80N001 R8 WASTE R E l10VA L 2 OP 0.203 3.90 REMOVE TURNBUCKLES FROM R8
  • 841022 010136 C80N001 R8 WASTE R E110VA L 1 UM 0.078 2.05 REMOVE TURNBUCKLES FROM RB

$841022 010136 C80N001 RB WASTE RLl10 VAL 1 RP 0.139 1.90 REMOVE TURNBUCKLE S F ROM RB 841024 010166 C80N001 RB WASTE R E t10V AL 2 IC 0.257 3.88 REMOVE SCRAP METAL & LUMBER FROM R8

  • 841024 010166 C80N001 RB WASTE REMOVAL 2 UM 0.278 3.83 REMOVE SCRAP METAL & LUMBER F ROM RB
  • 841024 010166 C80N001 RB WASTE R E t10VA L 1 RP 0.137 2.02 REMOVE SCRAP METAL & LUMBE R FROM RB 841030 010199 C80N001 RB WASTE R E t10VA L 2 CM 0.152 4.07 REMOVE LOW RAD TR ASH AND E QUIP FROM RD 841101 010209 C80N001 RB WASTE R E t10VA L 2 RP 0,419 3.37 INSPECTION / BAG 1 RASH. TOOLS & EQUIP.

841107 010242 C80N001 RB WASTE Rett 0 VAL 1 RP 0.161 1.83 FILL & RE MOVE WOODE N LSA BOXES

  • 841107 010242 C80N001 RB WASTE ret 10 VAL 1 EL 0.150 1.78 FILL & RE ttOVE WOODE N LSA 00XES
  • 841107 010242 C80N001 RB WASTE R E t t0VA L 1 CM 0.152 1.78 FILL & REMOVE WOODEN LSA BOXES 841107 010245 C80N001 R8 WASTE Rett 0 VAL 10 CN 1.448 25.90 CUT UP HATCH PLUGS FROM ELEVA10R SHAFT

DATE 022486 PAGE 67 PNO. 66 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR SUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP 1RCK. PERS. DEPT. EXPOS. TIME ACT ENTR . REM TASK DESCRIPTION

  • DATE.. NUMBER, NUMBER..............IVITY...................... CODE

. HOURS......... 841107 010249 C80N001 R8 WASTE R E t10V A L 4 CN 0.723 8.97 CUT UP LEAD SHIE1D DOLLIES 841113 010269 C80N001 R8 WASTE REMOVAL 32 CN 2.488 68.35 CUT UP PLUGS USING 0xY/ACETELENE 841114 010289 C80N001 R8 WASTE REMOVAL 17 CN 1.283 37.40 REMOVE AND DISMANTLE HATCH LIFT RIGS 841115 010297 C80N001 R8 WASTE REMOVAL 1 MM 0.075 2.03 R E MOVE TRASH AND EMPTY GAS C)LINDERS

  • 841115 010297 CF0N001 R8 WASTE REMOVAL 2 EL 0.056 3.12 REMOVE TR ASH AND EMPTY GAS CYLINDE RS
  • 841115 010297 C80N001 R8 WASTE REMOVAL 1 CM 0.037 1.07 REMOVE TRASH AND EMPTY GAS CYLINDERS 841128 010358 C80N001 R8 WASTE REMOVAL 2 RP 0.308 3.50 INSPECTION FOR REMOVAL OF SCRAP METAL 841122 010359 C80N001 RB WASTE REMOVAL 5 CN 0.235 5.78 RIG HATCH PLUG AND LEFT RIG 841204 010400 C80N001 R8 WASTE REMOVAL 1 CM 0.053 1.08 REMOVE HIGH RAD TRASH-CFT
  • B' TO AIRLOCK

$841204 010400 C80N001 R8 WASTE REMOVAL 1 OP 0.054 1.20 REMOVE HIGH RAD TRASH-CFT

  • B' 10 AIRLOCK 841206 010417 C80N001 R8 WASTE REMOVAL 4 OP 0.305 7.58 REMOVE SCR AP ME T AL FROM R8
  • 841206 010417 C80N001 RP WASTE REMOVAL 2 MM 0.423 5.03 RE MOVE SCR AP ME T AL F ROM RB

$841206 010417 C80N001 RB WASTE REMOVAL 1 CM 0.005 1.03 REMOVE SCR AP ME T AL F ROM RB $841206 010417 C80N001 R8 WASTE REMOVAL 2 UM 0.038 2.08 RE MOVE SCR AP ME T AL F ROM RB

  • B41206 010417 C80N001 RB WASTE REMOVAL 1 IC 0 025 2.78 REMOVE SCR AP ME T AL F ROM RB 841211 010447 C80N001 RB WASTE REMOVAL 1 CM 0.253 2.18 R E MOVE SCA88tE DUST FROM R8
  • 841211 010447 C80N001 R8 WASTE REMOVAL 2 OP 0.433 4.03 REMOVE SCABBLE DUST FROM RB
  • 841211 010447 C80N001 R8 WASTE REMOVAL.

I UM 0.183 1.70 REMOVE SCA88tE DOST FROM R8 841212 010458 C80N001 R8 WASTE REMOVAL 5 CN 0.544 10.85 RIG 30$* HATCHES TO 347' LEVEL U1 841213 010469 C80N001 R8 WASTE REMOVAL 1 RP 0.175 1.70 ]NSPECT'FOR 1 RASH & BAG-305'&347' LEVELS a C3 841214 010473 C80N001 R8 WASTE REMOVAL 1 EL 0.075 2.52 REMOVE STUD STORAGE RACKS & Mi GAS BTLS. 8 *841214 010473 C80N001 R8 WASTE REMOVAL 1 OP 0.091 2.55 REMOVE STUD STOR AGE R ACKS & MT GAS BTLS. 841219 010513 C80N001 R8 WASTE REMOVAL 7 CN 0.385 15.13 CUT UP 305* HATCHES AND REMOVE 841226 010545 C80N001 R8 WASTE REMOVAL 4 CN 0.281 8.62 CUT UP AND REMOVE LEAD SHIELD DOLLIES 841226 010546 C80N001 R8 WASTE REMOVAL 12 CN 0.880 25.28 CUT UP AND REMOVE 305' HATCHES 850103 010592 C80N001 RB WASTE REMOVAL 3 CN 0.240 7.15 CUT UP LE AD SHIE LD 00LLIE S-347 ' ELEV. 850103 010593 C80N001 R8 WASTE REMOVAL 7 CN 0.488 12.40 CUT UP HATCH PLUGS-347' BURNING AREA 850108 010626 C80N001 R8 WASTE REMOVAL 2 CN 0.091 3.73 CUT UP LE AD DOL L IE S 850108 010627 C80N001 R8 WASTE REMOVAL 1 RP 0.157 1,58 TNSPECT TRASH AND SCR AP FOR REMOVAL 850110 010643 C80N001 Ru WASTE REMOVAL 1 EL 0.049 1.47 REMOVE HIGH RAD TRASH FROM UNDER CFT

  • 850!!0 010643 C80N001 R8 WASTE REMOVAL 1 CM 0.048 1.43 REMOVE HIGH RAD TRASH FROM UNDER CFT 850116 010685 C80N001 R8 WASTE REMOVAL 1 EL 0.210 2.37 RFMOVE SCRAP METAL & EMPif GAS DOT TLES
  • 850116 010685 C80N001 R8 WASTE REMOVAL 2 RP 0.265 4.67 REMOVE SCRAP METAL & EMPTY GAS BOTTL ES
  • 850116 010685 C80N001 RB WASTE REMOVAL 2 CM 0.074 3.97 REMOVE SCRAP ME TAL & EMPTY GAS BOTTLES
  • 850116 010685 C80N001 R8 WASTE REMOVAL 2 OP 0.248 4.25 REMOVE SCRAP METAL & EMPTY GAS BOTTLES 850122 010727 C80N001 R8 WASTE REMOVAL 1 RP 0.154 2.05 INSPECT FOR TR ASH / BAG 1R ASH & EQUIPMENT
  • 850122 010727 C80N001 R8 WASTE REMOVAL 1 CN 0.148 2.02 INSPECT FOR TRASH / BAG TRASH & EQUIPMENT 850125 010749 C80N001 R8 WASTE REMOVAL 1 MM 0.072 1.68 REMOVE iCRAP WOOD & METAL FROM R8
  • 850125 010749 C80N001 RB WASTE REMOVAL 1 CM 0.129 1.67 REMOVE SCRAP WOOD & METAL FROM R8 850130 010774 C80N001 R8 WASTE REMOVAL 1 NM 0.051 1.35 REMOVE SCRAP METAL FROM RB
  • 850130 010774 C80N001 RB WASTE REMOVAL 1 RP 0.050 1.40 REMOVE SCR A P ME T AL F ROM R B
  • 850130 010774 C80N001 R8 WASTE REMOVAL 2 CM 0.218 3.15 REMOVE SCR AP ME TAL FROM R8 850204 010800 C80N001 RB WASTE REMOVAL 3 RP 0.344 4.42 INSPECTION / MOVE TRASH AND EOUIPMENT
  • 850204 010800 C80N001 R8 WASTE REMOVAL 1 CM 0.020 1.25 INSPECTION / MOVE TRASH AND EQUIPMENT 850215 010895 C80N001 RB WASTE REMOVAL 1 OP 0.128 1.85 REMOVE SCABBL E DUST F ROM RB
  • 850215 010895 C80N001 R8 WASTE REMOVAL 1 RP 0.143 1.78 REMOVE SCA88tf DUST FROM R8 850226 010991 C80N001 R8 WASTE REMOVAL 21 CN 1.209 45.40 CUT UP STUD STORAGE RACKS 850301 011016 C80N001 RB WASTE REMOVAL 1 OS 0.144 2.17 REMOVE SCR AP ME T AL F ROM RB
  • 850301 011016 C80N001 R8 WASTE REMOVAL 1 CN 0.143 2.17 REMOVE SCRAP METAL FROM RB 850305 011047 C80N001 R8 WASTE REMOVAL 1 OS 0.189 2.95 REMOVE LOW RAD TRASH AND SCRAP METAL

DATE 022486 PAGE 68 PNO. 67 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR DUILDING DECONTAMINATION 286 D

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ENTR. CODE. REM . HOURS TASK DESCRIPTION ACTIVITY

  • DATE. NUMBER. NUMBER
  • 850305 011047 C80N001 RB WASTE REMOVAL 2 OP 0.070 2.47.

REMOVE LOW RAD TRASH AND SCRAP METAL

  • 850305 011047 C80N001 RB MSTE Ut10 VAL 2 CM 0.066 2.43 REMOVE LOW RAD TRASH AND SCRAP METAL
  • 850305 011047 C80N001 RB WASTE REMOVAL 1 MM 0.230 2.73 PEMOVE LOW RAD TRASH AND SCRAP METAL
  • 850305 0!!047 C80N001 RB WASTE REMOVAL 1 RP 0.205 2.93 REMOVE LOW RAD TRASH AND SCRAP t1ETAL
  • 850305 011017 C80N001 RB WASTE REMOVAL 1 CN 0.250 2.73 REMOVE LOW RAD TRASH AND SCRAP METAL 850308 011077 C80N001 RB WASTE REMOVAL 2 OP 0.031 5.90 REMOVE WOODEN LSA BOXES
  • 850308 0!!077 C80N001 RB WASTE REMOVAL 1 RP 0.020 2.42 R EMOVE WOODE N LSA DOXE S

$850308 011077 C80N001 RH WASTE REMOVAL 1 CM 0.017 2.45 REMOVE WOODf N LSA BOXE S 850313 011114 C80N001 RB WASTE R E MOVA t. 2 OS 0.242 3.95 REMOVE TR ASH & ME T AL F ROM 305

  • LEVEL
  • 850313 011114 C80N001 R8 WASTE REMOVAL 3 OP 0.623 7.50 REMOVE TRASH & METAL FROM 305* LEVEL

$850313 011114 C80N001 RD WASTE REMOVAL 2 CM 0.279 3.80 REMOVE TRASH & METAL FROM 305* LEVEL

  • 850313 011114 C80N001 RH WASTE REMOVAL 2 RP 0.243 3.90 REMOVE TRASH & METAL FROM 305* LEVEL 850321 011183 C80N001 RD WASTE RE MOVAL 3 OP 0.618 7.57 REMOVE TRASH & SCRAP FROM 305* LEVEL
  • 850321 011183 C80N001 RB WASTE REMOVAL 2 CM 0.444 5.28 REMOVE TRASH & SCRAP FROM 305* LEVEL
  • 850321 011183 C80N001 RO WASTE REMOVAL 2 UM 0.382 4.45 REMOVE TRASH & SCR AP F ROM 305
  • LEVEL
  • 850321 011183 C80N001 RB WASTE REMOVAL 4 RP 0.396 6.17 R E MOVE TRASH & SCRAP FROM 305* LEVEL 8503N 011225 C80N001 RB WASTE REMOVAL 2 OP 0.305 5.60 REMOVE TRASH AND SCRAP METAL
  • 850326 011225 C80N001 RH WASTE REMOVAL 1 CM 0.180 2.77 REMOVE TRASH AND SCRAP METAL C80N001 i. SUBTOTAL -

EXP TRCK NUMBER = PERS ENTR 606 U1 EXPOS REM = 54 031000 1125.3300 TIME HOURS * ".801015 085320 C90K001 RB DATA ACQUISITION 2 HP 0.765 2.45 RADIOLOGICAL SURVEY OF RB 8

  • 801015 085320 C90K001 RB DATA ACQUISITION 1 CN 0.600 1.50 RADIOLOGICAL SURVEY OF RB 801130 005564 C90K001 RB DATA ACQUISti!ON 2 OP 0.724 3.57 OPS-HP-NRC INSPECTION AND SURVEY
  • 801130 085564 C90K001 RB DATA ACQUISITION 1 VI 0.300 2.17 OPS-HP-NRC INSPECTION AND SURVEY
  • 801130 005564 C90K001 RB DATA ACQUISITION 2 IC 0.740 3.27 OPS-HP-NRC INSPECTION AND SURVEY
  • 801130 085564 C90K001 RB DATA ACQUISITION 1 HP 0.419 1.33 OPS-HP-NRC INSPECTION AND SURVEY
  • 801130 085564 C90K001 RB DATA ACQUISITION 3 CN 1.070 6.40 OPS-HP-NRC INSPECTION AND SURVE Y 801130 005566 C90K001 RB DATA ACQUISITION 3 CN 0.707 4.00 DECON TEST MEASUREMENTS 802211 085868 C90K001 RB DATA ACQUISITION 4 HP 1,890 6.93 STAGE VIDEO AND TAKE PHOTOGRAPHS
  • 801211 085868 C90K001 RB DATA ACQUISITION 2 OP 0.020 11.82 STAGE VIDEO AND TAKE PHOTOGRAPHS
  • 801211 085868 C90h001 RB DATA ACQUISITION 2 CN 0.505 3.67 ST AGE VIDE O AND TAKE PHOTOGRAPHS
  • 801211 085868 C90K001 RB DATA ACQUISITION 1 CR 0.425 1.45 STAGE VIDEO AND TAKE PHOTOGRAPHS
  • 801211 0B5868 C90K001 RB DATA ACQUISITION 1 AD 0.270 2.58 STAGE VIDEO AND TAKE PHOTOGRAPHS 801211 085869 C90K001 RB DATA ACQUISITION 2 HP 0.700 3.80 REACTOR HEAD AND P.C.

SURVEYS

  • 801211 085869 C90K001 RB DA.TA ACQUISITION 1 CN 0.235 2.27 REACTOR HEAD AND P C. SURVEYS 801211 085870 C90K001 RB DATA ACQUISITION 3 CR 0.655 3.50 DECON TESTS / VIDEO CPERATION 810203 000282 C90K001 RB DATA ACQUI*ITION 9 HP 0.083 25.33 SAMP& TR ASH REMOVAL / ANTE R00M PRE P/HP COV
  • 810203 000282 C90K001 RB DATA ACQUISITION 11 CN 0.035 31.42 SAMP&iR ASH REMOVAL /ANIER00M PRE P/HP COV
  • 810203 000282 C90K001 RB DATA ACQUISITION 5 OP 0.000 4.02 SAMP& TRASH REMOVAL / ANTE RDOM PRf P/HP COV

$810203 000282 C90K001 RB DATA ACQUISITION 8 IC 0.001 7.43 SAMP& T R ASH REMOVAL / ANTE ROOM PRE P/HP COV

  • 810203 000282 C90K001 RB DATA ACQUISITION 10 UM 0.007 11.47 SAMP&1 RASH REMOVAL / ANTEROOM PREP /HP COV
  • 810203 000282 C90K001 RB DATA ACQUISITION 6 EL 0.000 5.02 SAMP&TR ASH REMOVAL / ANTEROOM PRE P/HP COV
  • 810203 000282 C90K001 RB DATA ACQUISITION 1 MM 0.000 1.08 SAMP&IR ASH REMOVAL / ANTEROOM PRE P/HP COV

$810203 000282 C90K001 RB DATA ACQUISITION 1 AD 0.005 1.75 SAMP&T R ASH REMOVAL / ANTE ROOM FRE P/HP COV

  • 810203 000282 C90K001 RB DATA ACQUISITION 1 CR 0.000 0.67 SAMP& TRASH REMOVAL / ANTE ROOM PRE P/HP COV
  • 810203 000282 C90K001 RB DATA ACQUISITION 1 ES 0.000 1.03 SAMP&T R ASH REMOVAL /ANIER00M PRE P/HP COV 810205 000325 C90K001 RB DATA ACOUISITION 1 CR 0.225 1.68 DECON TE ST - 34 7
  • LEVEL
  • 810205 000325 C90K001 RB DAIA ACQUISITION 2 CN 0.604 3.37 DECON TEST - 347' LEVEL

DATE 022486 PAGE 69 PNO. 68 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS.DFPT . EXPOS. TIME

  • DATE... NUMBER. NUMBER.............................................

...........................................PT. ION ACTIVITY ENIR. CODE. REM . HOURS. TASK DESCRI s.... 1.MM 0.000 2.00 PACKAGE PAINT CHIP SAMPLES 810303 000598 C90K001 RB DATA ACQUISITION

  • 810303 000598 C90K001 RB DATA ACQUISITION 1 HP 0.000 0.50 PACKAGE PAINT CHIP S AMPL E S
  • 810303 000598 C90K001 RB DATA ACQUISITION 2 CN 0.000 2.00 PACKAGE PAINT CHIP SAMPLE S 810317 000693 C90K001 RB DATA ACQUISITION 5 CN 2.734 12.62 SUMP SAMP/ COLUMN TEST /CHK TV/ TUNNEL SURV 810319 000721 C90K001 RB DATA ACQUISITION 3 CN 0.295 2.73 REPAIR CCTV CAMERA / POWER TO RESIN COLUMN 810319 000714 C90K001 RB DATA ACQUISITION 2 CN 0.608 2.32 RES COL TEST /CRDMLMISSILE SHIELD SURVEYS
  • 810319 000714 C90K001 RB DATA ACQUISITION 1 EL 0.155 0.85 RES COL TEST /CRDM&MISS!LE SHIELD SURVEYS
  • 810319 000714 C90K001 RB DATA ACQUISITION 1 OP 0.210 1.47 RES COL TEST /CROK& MISSILE SHIELD SURVEYS 810320 000724 C90K001 RB DATA ACQUISITION 1 OP 0.102 0.32 SHUT DOWN COL TEST / RETRIEVE SAMP CARBOY
  • 810320 000724 C90K001 RB DATA ACQUISITION 1 CN 0.132 0.32 SHUT DOWN COL TEST / RETRIEVE SAMP CARBOY 810320 000725 C90K001 RB DATA ACQUISITION 3 CN 0.000 4.83 HP COVERAGE FOR ENTRY 7 810430 000986 C90K001 RB DATA ACQUISITION 2 MM 0.254 2.33 MODIF Y PENETRATION R-561
  • 810430 000986 C90K001 RB DATA ACQUISITION 2 OP O.000 2.67 MODIFY PENETRATION R-561 810514 001058 C90K001 RB DATA ACQUISITION 2 UM 0.000 1.33 PACKAGE AND MOVE SUMP SAMPLES
  • 810514 001058 C90K001 RB DATA ACQUISITION 3 CN.

0.010 5.67 PACKAGE AND MOVE SUMP SAMPLES 810514 001059 C90K001 RB DATA ACQUISITION 1 OP 0.315 2.75 CRDM SURVEY

  • 810514 00!n59 C90K001 RB DATA ACQUISITION 1 CN O.416 2.67 CRDM SURVE Y 810514 001060 C90K001 RB DATA ACQUISITION 4 CN 0.732 3,34 SUMP SAMPLINI 8
  • 810514 001060 C90K001 RB DATA ACQUISITION 1 CR 0.200 0.83 SUMP SAMPLING C90K001 RB DATA ACQUISITION 2 OP 0.423 3.33 SUMP SAMPLING h"$ *810514 001060 810514 001055 C90K001 RB DATA ACQUISITION 1 AD 0.600 2.83 LARGE SCALE DECON TEST
  • 810514 001055 C90K001 RB DATA ACQUISITION 2 CR 1.100 5.00 LARGE SCALE DECON TEST
  • 810514 001055 C90K001 RB DATA ACQUISITION 1 CN 0.200 2.67 LARGE SCALE DECON TEST 810514 001056 C90K001 RB DATA ACQUISITION 4 CR 0.815 5.62 LARGE SCALE DECON TEST
  • 810514 001056 C90K001 RB DATA ACQUISITION 2 HP 0.500 3.03 LARGE SCALE DECON TEST
  • 810514 001056 C90K001 RB OATA ACQUISITION 1 CN 0.624 2.58 LARGE SCALE DECON TEST 810528 001152 C90K001 RB DATA ACQUISITION 2 CN 1.223 8.15 GAMMA SCAN OF ELEV 305 810625 001349 C90K001 RB DATA ACQUISITION 2 CN 0.642 3.33 SMEAR SURVEY OF WALLS 810723 001530 C90K001 RB DATA ACQUISITION 2 CR 0.005 5.30 ANTEROOM SUPPORT
  • 810723 001530 C90K001 RB DATA ACQUISITION 3 OP 0.015 6.30 ANTEROOM SUPPORT
  • 810723 001530 C90K001 RB DATA ACQUISITION 2 HP 0.015 7.33 ANT E R0OM SUPPOR T

$810723 001530 C90K001 RB DATA ACQUISITION 3 CN 0.025 7.42 ANIER00M SUPPORT 810723 001531 C90K001 RB DATA ACQUISITION 1 OP 0.604 1.70 RV HEAD SURVEY / SAMPLE REMOVAL

  • 810723 001531 C90K001 RB DATA ACQUISITION 1 CN 0.641 1.70 RV HEAD SURVEY / SAMPLE REMOVAL 810723 001532 C90K001 RB DATA ACQUISITION 1 IC 0.656 2.13 INST REMOVAL / INSTALL AREA RAD MONIT INST
  • 810723 001532 C90K001 RB DATA ACQUISITION 1 HP 0.264 1.13 INST REMOVAL / INSTALL AREA RAD MONIT INST
  • 810723 001532 C90K001 RB DATA ACQUISITION 1 CN 0.610 2.13 INST REMOVAL / INSTALL AREA RAD MONIT INST 810723 001534 C90K001 RB DATA ACQUISITION 1 CN 0.464 1.45 SAMPLE REMOVAL / PHOTOGRAPHS
  • 810723 001534 C90K001 RB DATA ACQUISITION 1 OP 0.400 1.45 SAMPLE REMOVAL / PHOTOGRAPHS 810827 001814 C90K001 RB DATA ACQUISITION 2 CN 0.862 7.50 GAFVIA SPEC AND R0-2A ME ASUREMENTS 810827 001815 C90K001 RB DATA ACQUISITION 2 HP 0.614 4.45 HP SURVEYS
  • 810827 001815 C90K001 RB DATA ACQUISITION 1 CN 0.400 2.75 HP SURVEYS 810827 001816 C90ko01 RB DATA ACQUISITION 1 CN 0.310 1.75 OTSG CLEANING LINE WALKDOWN AND PHOTOS 810903 001866 C90K001 RB DATA ACQUISITION 2 CN 0,140 1.33 WATER 1EVEL INSPECT ION / POSITION CAMER A 810924 002035 C90KC01 RB DATA ACQUISITION 1 CN 0.140 1.17 OBTAIN PAINT SAMPLE 810924 002036 C90K001 "B DATA ACQUISITION 2 CN 0.550 4.33 DEFtlELING TOOL INVENTORY / PHOTOS
  • 810924 002036 C90K001 RB DATA ACQUISITION 1 MM 0.349 2.17 DEFUELING TOOL I NVE NI OR Y / PHO T OS 810924 002037 C90K001 RB DATA ACQUISITION 1 CN 0.227 1.52 DECON CHAR ACTE R!lAT ION PHOTOS 810924 002039 C90X001 RB DATA ACQUISITION 2 CN 0.900 2.75 AIRLOCK LEAK RATE TESTS

$810924 002039 C90K001 RB DATA ACQUISITION 1 CN 0.582 1.17 AIRLOCK LEAK RATE TESTS

DATE 022486 PAGE 70 PNO 69 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR DUILDING DECONTAMINATION 286 D

  • RWP

.RuP .EXP TRCK. PERS. DEPT. EXPOS. TIME .... TASK DESCRIPTION ACT ...........I V I. T Y ..... HOURS........,......

  • DATE........ NUMBER

. NUMBER . ENTR ............... C OD E.... R E.M

  • ....s.

......r.............................., 820617 004088 C90K001 RB DATA ACQUISITION 1 HP 0.209 1.72 SURVE Y. IDE NTIF Y. PHOTO F LOOR PENETS-305'

  • 820617 004088 C90K001 RB DATA ACQUISITION 2 CN 0,687 4.58 SURVE Y, IDE N T IF Y. PHOT O F LOOR PENEIS-305' 820617 004089 C90K001 RB DATA ACQUISITION 2 HP 0.688 3.60 HP SURVE Y/PL ACE TLD TREE 820622 004121 C90K001 RB DATA ACQUISITION 2 HP 0.311 4.17 TLD PLACEMENT /HP SURVEYS 820622 004122 C90K001 R8 DATA ACQUISITION 3 CN 0.887 4.42 REMOVE HATCH PLUG FOR TLD PLACEMENT 820622 004131 C90K001 RB DATA ACQUISITION 1 HP 0.384 1.00 OBTAIN SCRAPL SAMPLE-FLOOR 282* LEVEL
  • 820622 004131 C90K001 RB DATA ACQUISITION 1 CN 0.289 1.00 00TAIN SCRAPE SAMPLE-FLOOR 282* LEVEL 820623 004133 C90K001 R8 DATA ACQUISITION 3 HP 0.425 6.92 HP SURVEY AND COVERAGE 820630 004188 C90K001 RD DATA ACQUISITION 2 HP 0.140 3.02 HP SURVEY AND COVERAGE 820727 004377 C90K001 R8 DATA ACQUISITION 5 CN 0.613 7.42 SNUBBER DISASSEMBLY AND REMOVAL 820727 004383 C90K001 R8 DATA ACQUISITION 2 CN 0.000 0.75 MOVE SNUBBERS-ANTEROOM TO MODEL ROOM
  • 820727 004383 C90K001 R8 DATA ACQUISITION 1 HP 0.000 1.33 MOVE $ NUB 0ERS-ANTEROOM TO MODEL ROOM 820728 004385 090K001 R8 DATA ACQUISITION 3 CM 0.048 7.25 TRANSPORT SAMPLE TO SDS HRFG8 AND LAB
  • 820728 004385 C90K001 R8 DATA ACQUISITION 1 HP 0.015 2.42 TRANSPORT SAMPLE TO SDS HRFGB AND LAS
  • 820728 004385 C90K001 R8 DATA ACQUISITION 1 UM 0.010 1.58 TRANSPORT SAMPLE TO SDS HRFGB AND LAB
  • 820728 004385 C90K001 R8 DATA ACQUISITION 1 CR 0.005 0.75 TRANSPORT SAMPLE TO SDS HRFG8 AND LAB
  • 820728 004385 C90K001 RB DATA ACQUISITION 1 CN 0.008 1.42 TRANSPORT SAMPLE TO SDS HRFGB AND LAB 820812 004491 C90K001 RB DATA ACQUISITION 2 CN O.210 4.12 REMOVE SOLENOID AHVG 820820 004550 C90K001 RB DATA ACQUISITION 1 HP 0.126 1.43 INSTAL ( POWER BUGGY / REMOVE P.C.

PENDANT

  • 820820 004550 C90K001 RB DATA ACQUISITION 4 CN 0.677 7.62 INSTALL' POWER BUGGY / REMOVE P.C.

PENDANT -s 820824 004593 C90K001 RB DATA ACQUISITION 2 CN 0.332 3.80 TV SURVEY OF 282' ELEV. Ln *820824 004593 C90K001 RB DATA ACQUISITION 1 ES 0.292 2.47 TV SHRVEY OF 282' ELEv. CJ *820824 004593 C90K001 RB DATA ACQUISITION 1 HP 0.139 1.42 TV SURVEY OF 282* E LE V. 8 820831 004642 C90K001 RB DATA ACQUISITION 1 Et n ??' 1.92 TV SURVEY OF 282' ELEV. 820909 004679 C90K001 RB DATA ACQUISITION 3 CN 0.464 5.25 WIRE SPLICE AND CADLE SAMPLING

  • 820909 004679 C90K001 R8 DATA ACQUISITION 1 HP 0.195 2.17 WIRE SPLICE AND CABLE SAMPLING 820915 004706 C90K001 RB DATA ACQUISITION 1 HP 0.074 1.33 REMOVE AND REPLACE PRESSURE SWITCH
  • 820915 004706 C90K001 RB DATA ACQUISITION 2 CN 0.204 2.92 REMOVE AND REPLACE PRESSURE SWITCH 820929 004803 C90K001 RB DATA ACQUISITION 2 HP 0.689 4.23 TV SURVEY OF 282' ELEV.
  • 820929 004803 C90K001 R8 DATA ACQUISITION 4 IC 0.616 7.47 TV SURVEY OF 282* ELEV
  • 820929 004803 C90K001 RB DATA ACQUISITION 1 CN 0.325 2.02 TV SURVEY OF 282* ELEV.

821015 004915 C90K001 RB DATA ACQUISITION 2 HP 0.461 4.)7 TV SURVEY OF 282' ELEV

  • B21015 004915 C90K001 RB DATA ACQUISITION 4 CN 1.347 2.40 TV SURVEY OF 282* ELEV.

821109 005077 C90K001 RB DATA ACQUISITION 1 CN 0.000 1.25 INSTALL SAMPLE PROBE 821210 005298 C90K001 RB DATA ACQUISli!ON 5 CN 1.019 9.73 TEMP LIGHTS-305'/TV SURVEY OF CA-V-48 821213 005303 C90K001 RB DATA ACQUISITION 2 CN 0.105 1.52 TV SURVEY - 305' ELEV./ EQUIPMENT REMOVAL 821222 005388 C90K001 RB DATA ACQUISITION 3 CN 0.334 4.48 REMOVE CRD CABLE SAMPLES 830107 005501 C90K001 RB DATA ACQUISITION 2 IC 0.241 3.37 REPAIR RB SUMP CAMERA 830405 006216 C90K001 R8 DATA ACQUISITION 2 CN 0.409 5.47 TV SURVEY OF TRASH RACK 830406 006221 C90K001 R8 DATA ACQUISITION 2 CN 0.126 3.18 RB WALKDOWN 830615 006735 C90K001 R8 DATA ACQUISITION 1 HP 0.187 2.62 INSPECT PAINT AND CONCRETE IN R8

  • 830615 006735 C90K001 RB DATA ACQUISITION 3 CN 0.524 7.51 INSPECT PAINT AND CONCRETE IN R8 830616 006742 C90K001 R8 DATA ACQUISITION 3 CN 0.308 4.78 REMOVE CFT TRAN5DUCERS 830708 006833 C90K001 RB DATA ACQUISITION 2 IC 0.335 2.97 AH-C13 SWITCH REMOVAL 830712 006942 C90K001 RB DATA ACQUISITION 2 CN 0.234 2.63 REMOVE CABLE AND CONDUIT 830715 006961 C90K001 RB DATA ACQUISITION 4 CN 0.452 8.20 REPLACE LIMIT SWITCH-VALVE AH-V-28 830719 006998 C90K001 R8 DATA ACQUISITION 2 CN 0.013 7.62 DISASSEMBLE. INSPECT AND WIPE SNUBBERS 830721 007007 C90K001 R8 DATA ACQUISITION 2 IC 0.335 3.02 DISCONNECT INCORE DETECTORS 830721 007009 C90K001 RB DATA ACQUISITION 2 CN 0.270 3.50 INSTALL TE MPOR AR Y LIGHT STRINGER 830722 007021 C90K001 RB DATA ACQUISITION 5 CN 1.248 9.33 CORE EORE PENETRATION - 305* FLOOR

DATE 022486 PAGE 71 PNO. 70 .TMI-2 UNC: DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 0

  • RWP

.RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ...ENTR.............. HOURS........,................. E. SC R I P.T I O N . CODE. REM TASK D ACTIVITY

  • DATE.. NUMBER. NUMBER.......................................
  • 830722 007021 C90K001 RB DATA ACQUISITION 1 HP 0.143 1.82 CORE BORE PENETRATION - 305' FLOOR 830725 007059 C90K001 RB DATA ACQUISITION 2 CN 0.198 3.52 CORE BORE PENETRATION / INSERT CAMEPA 830729 007077 C90K001 RB DATA ACQUISITION 1 IC 0.102 1.10 DISCONNECT INCORE SHORTING DEVICES 830729 007083 C90K001 Rh DATA ACQUISITION 4 CN 0.731 6.88 BORE 4 IN. HOLE-305' TO RCDT ROOM 830801 007102 C90K001 RB DATA ACQUISITION 4 CN 0.742 6.57 COREBORE 4 IN. HOLE / CUT RCDT VENT LINE
  • 830801 007102 C90K001 RB DATA ACQUISITION 1 HP 0.109 1.70 COREBORE 4 IN. HOLE / CUT RCDT VENT LINE 830803 007117 C90K001 RB DATA ACQUISITION 2 IC 0.033 0.85 RECONNECT 7 INCORE INSTRUMENT CABLES 830805 007132 C90K001 RB DATA ACQUISITION 2 CN 0.303 3.15 COREBORE/ CAMERA INSPECTION - 305' LEVEL 830812 007198 C90K001 RB DATA ACQUISITION 2 CN 0,161 3.45 INSTALL SAMPLE LINE-SUMP PUMP DISCHARGE 830815 007217 C90K001 RB DATA ACQUISilION 1 CN 0.055 0.70 INSPECT SSTR NEUIRON DOSIMETER AREA 8309'12 007451 C90K001 RB DATA ACQUISITION 2 OP 0.251 2.83 08TAIN SUMP SADPLE
  • 830912 007451 C90K001 RB DATA ACQUISITION 2 HP 0.247 2.88 OBTAIN SUMP SAMPLE
  • 830912 007451 C90K001 RB DATA ACQUISITION 2 CM 0.114 2.90 OBTAIN SUMP SAMPLE 830914 007485 C90K001 RB DATA ACQUISITION 2 IC 0.138 2.57 UNDERHEAD VIDEO INSPECTION
  • 830914 007485 C90K001 RB DATA ACQUISITION 1 HP 0.178 3.50 UNDERHEAD VIDEO INSPECTION
  • 830914 007485 C90K001 RB DATA ACQUISITION I RP 0.272 3.47 UNDERHEAD VIDEO INSPECTION
  • 830914 007485 C90K001 RB DATA ACQUISITION 1 CN 0.149 3.45 UNDERHEAD VIDED INSPECTION 830920 007525 C90K001 RB DATA ACQUISITION 3 IC 0.455 6.35 v1DEO SURVEY OF 282' FROM 305' LEVEL
  • 830920 007525 C90K001 RB DATA ACQUISITION 1 CN 0.425 2.07 VIDEO SURVEY OF 282* FROM 305' LEVEL 8

830920 007526 C90K001 RB DATA ACQUISITION 1 OP 0.099 0.97 OBTAIN-SUMP SAMPLE

  • 830920 007526 C90K001 RB DATA ACQUISITION 1 HP 0.248 2.03 OBTAIN SUMP SAMPLE I"[
  • 830920 007526 C90K001 RB DATA ACQUISITION 1 CN 0.099 0.80 OBTAIN SUMP SAMPLE 830921 007534 C90K001 RB DATA ACQUISITION 2 CN 0.689 5.17 SAMPLE PAINT COATING 830921 007531 C90K001 RB DATA ACQUISITTON 8 CN 1.216 15.92 CORE BORE SAMPLING 830922 007542 C90K001 RB DATA ACQUISITION 1 OP 0.428 2.40 SUMP SAMPLES
  • 830922 007542 C90K001 RB DATA ACQUISITION 1 HP 0.231 2.43 SUMP SAMPLES 2830922 007542 C90K001 RB DA1A ACQUISITION 1 CM 0.197 2.43 SUMP SAMPLE S 830926 007564 C90K001 RB DATA ACQUISITION 5 CN 1.097 8 15 CORE BORE SAMPLES 830930 007602 C90K001 RB DATA ACQUISITION 1 IC 0.105 2.10 VIDEO SURVEY OF 282* LEVEL

$830930 007602 C90K001 RB DATA ACQUISITION 1 CN 0.132 2.08 VIDEO SURVE Y OF 282' LEVEL 831003 007676 C90K001 RB DATA ACQUISITION 4 CN 0.489 5.63 REPAIR CORE BORE HOLES 831028 007840 C90K001 RB DATA ACQUISITION 3 CN 0.000 10,13 AU10 RADIOGRAPHY SAMPLE MANIPULATIONS 831031 007845 C90K001 RB DATA ACQUISITION 1 QA 0.211 1.40 CORE DRILL 4 IN. HOLE IN 305' FLOOR

  • 831031 007845 C90K001 RB DATA ACQUISITION 3 CN 0.545 3.85 CORE DRILL 4 IN. H0LE IN 305* FLGOR 831107 007883 C90K001 RB DATA ACQUISITION 1 HP 0.070 0.73 CORE HCRE 4 IN. HOLE S-305 ' E LEV
  • 831107 007883 C90K001 RB DATA ACQUISITION 4 CN 1.081 11.63 CORE BORE 4 IN. HOLE S-305' E LEV 831108 007905 C90K001 RB DATA ACQUISITION 11 CN 0.029 25.17 SECTION CORE SAMPLES FOR ANALYSIS 831112 007922 C90K001 RB DATA ACQUISITION 5 CN 0.000 11.32 CORE SAMPLE EXPERIMENT 831114 007921 C90K001 RB DATA ACQUISITION 1 EL 0,093 1.72 REMOVE JIB CRANE CONTROL PENDANT & CABLE

$831114 007921 C90K001 RB DATA ACQUISITION 4 CN 0.316 6.53 REMOVE JIB CRANE CONTROL PENDANT & CABLE $831114 007921 C90K001 RB DATA ACQUISITION 1 HP 0.055 1.35 REMOVE JIB CRANE CONTROL PE NDANT & CABLE 831121 007957 C90K001 RB DATA ACQUISITION 2 CN 0.556 6.15 CUT HOLE IN RLUT VENT LINE FOR SAMPLE 831205 008041 C90K001 RB DATA ACQUISITION 3 RP 0,009 4.00 TRANSPORT RCDT AND PLENUM SAMPLES

  • 831205 008041 C90K001 RB DATA ACQUISITION 1 UM 0.002 1.92 TRANSPORT RCOT AND PLENUM SAMPLES
  • 831205 008041 C90K001 RB DATA ACQUISITION 2 OP 0.001 1.75 TRANSPORT RCOT ANO PLE NUM SAMPL ES
  • 831205 008041 C90K001 RB DATA ACQUISITION 1 Fv4 0.000 0.53 TRANSPORT RCDT ANi PLENUM SAMPLES
  • 831205 008041 C90K001 RB DATA ACQUISITION 1 CN 0.000 3.35 TRANSPOR T RCDT AND PLE NUM SAMPLE S 831205 008027 C90K001 RB DATA ACQUISITION 1 HP 0.218 4.22 RCDT VIDEO SURVL Y/L IQUID SAMPL E S
  • 831205 008027 C90K001 RB DATA ACQUISITION 2 IC 0.754 8.32 RCDT VIDt0 SURVEY / LIQUID SAMPLES 831205 008029 C90K001 RB DATA ACQUISITION 2 CN 0.093 1.45 DATA ACQUISITION ACTIVITIES-305' & 347'

DATE 022486 PAGE 72 PNO. 71 .TMI-2 UNC: DOS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D

  • RWP

_RWP .EXP TRCK. PERS. DEPT. EXPOS. TIME ACTIV . ENTR TASK DESCRIPTION

  • D A T E... NUMBE.R. NUMB E.R................ITV........................ CODE........ REM........ HOURS..........................................................

s.... 2831205 008029 C90K001 RB DATA ACQUISITION 1 HP 0.074 0.88 DAT A ACQUIS!! ION ACTIVITIE S-305 ' & 347' 831212 008076 C90K001 RB DATA ACQUISITION 1 HP 0.340 3.93 RCDT VIDEO INSPECTION /5LUDGE SAMPLING

  • 831212 008076 C90K001 RB DATA ACQUISITION 3 IC 1.095 10.85 RCDT VIDEO INSPECTION / SLUDGE SAMPLING 831219 008123 C90K001 RB DATA ACQUISITION 2 CM 0,139 1.70 DEST 4GE LEAD SHIELDING / POSITION AIRLIFT
  • 831219 008123 C00K001 RB DATA ACQUISITION 1 EL 0.056 0.77 DEST 4GE LEAD SHIELDING / POSITION A!RLIFT
  • 831219 008123 C90K001 RB DATA ACQUISITION 1 UM 0.065 0.92 DESTAGE LEAD SHIELDING / POSITION AIRLIFT 840323 008690 C90K001 RB DATA ACQUISITION 1 CN 0.140 1.73 DATA ACQUISITION-305*. 347* &

'A' D RING

  • 840323 008690 C90K001 RB DA1A ACQUISITION 1 HP 0.126 1.73 DATA ACQUIS!110N-305". 347' &

'A' D RING 840328 008719 C90K001 RB DATA ACQUISITION 4 CN 0.320 4.83 REM 0/E T R ANSDUCE RS F ROM CF T-B 840426 008898 C90K001 RB DATA ACQUISITION 4 CN 0.488 7.53 INST %LL SOLENDID & LIMIT SWITCH-AHV-2A 840608 009157 C90K001 RB DATA ACQUISITION 1 HP 0.103 0.60 TLD siUDY - 305' ELEV 840614 009204 C90K001 RB DATA ACQUISITION 1 CM 0.000 1.68 UCI ANALYSIS OF PAINT CHIPS

  • 840614 009204 C90K001 RB DATA ACQUISITION 1 CN 0.001 1.67 UCI ANALYSIS OF PAINT SHIPS 840718 009487 C90K001 RB DATA ACQUISITION 1 ES 0.079 1.67 DATA ACQUISITION-ILD TREES AND STRINGS 4840718 009487 C90K001 RB DATA ACQUISITION 1 CN 0,070 1.80 DATA ACQUISli10N-ILD TREES AND STRINGS 840722 009518 C90K001 RB DATA ACQUIS!!!ON 2 CN 0.075 1.40 TLD CHARAClfRIZATION OF RB

$840722 009518 C90K001 RB DATA ACQUISITION 1 RP 0.093 2.67 ItD CHARACTERIZATION OF RB

  • 840722 009518 C90K001 RB DATA ACQUISITION 1 ES 0.073 1.47 llD CHARACTER!1ATION OF RB e

840730 009568 C90K001 RB DATA ACQUISITION 1 RP 0.060 0.98 T LD PL ACEME NT

  • 840730 009568 C90K001 RB DATA ACQUISITION 1 ES 0.062 1.03 TLD PLACEMENT

-s on 840802 009606 C90K001 RB DATA ACQUISITION 1 HP 0.060 1.27 DATA ACQUISITION-305', 347' AND CANAL U1 *840802 009606 C90K001 RB DATA ACQUISITION 1 CN 0.074 1.28 DATA ACQUISITION-305*, 347' AND CANAL 8 840806 009626 C90K001 RB DATA ACQUISITION 3 CN 0.169 3.50 DATA ACQUISITION-305', 347' AND CANAL $840806 009626 C90K001 RB DATA ACQUISITION 1 OP 0.030 0.73 DATA ACQUISITION-305', 347' AND CANAL

  • 840806 009626 C90K001 RB DATA ACQUISITION 2 HP 0.062 1.50 DATA ACQUISITION-305', 347* AND CANAL 840822 009753 C90K001 RB DATA ACQUTSITION 1 OP O 060 1.07 DATA ACQUISITION /0PERATIONS SUPPORT
  • 840822 009753 C90K001 RB DATA ACQUISITION 1 CN 0.029 0.67 DATA ACQUISITION /0PERATIONS SUPPORT 840824 009766 C90K001 RB DATA ACQUISITION 1 OP 0.020 0.67 DATA ACQUISITION IN RB

$840824 009766 C90K001 RB DATA ACQUISITION 1 ES 0.022 0.67 DATA ACQUIS!! ION IN RB 840928 010004 C90K001 RB DATA ACQUISITION 1 CN 0.011 0.52 LEAK CHECK SF-V-103 841017 010118 C90K001 RB DATA ACQUISITION 1 CM 0.050 0.98 CONTAMINATION STUDY OF D RING HANDRAILS 841024 010163 C90K001 RB DATA ACQUISITION 9 CN 1.107 19.83 PLUG EQUIP HAICH/ INSTALL ROBOT MONORAIL 841024 010167 C90K001 RB DATA ACQUISli!ON 2 CM 0.068 1.98 INSTALL & RE TRIE VE TLDS-305' DY ELEVATOR

  • 841024 010167 C90K001 RB DATA ACQUISITION 1 ES 0.181 1.47 INSTALL & RE T RIE VE ILDS-305' BY ELEVATOR 841025 010171 C90K001 RB DATA ACQUISITION 2 CN 0.050 1.42 power FOR R000 TICS MONORAIL 841026 010176 C90K001 RB DATA ACQUISITION 1 UM 0.075 1.02 DBTAIN SCABBLE DUST & PAINT CHIP SAMPLES
  • 841026 010176 C90K001 RB DATA ACQUISITION 1 EL 0.109 1.00 08TAIN SCAB 9tE DUST & PAINT CHIP SAMPLES 841030 010198 C90k001 RB DATA ACQUISITION 1 UM 0.025 0.57 CONTAMINATION STUDY OF D RING HANDRAILS 841031 010205 C90K001 RB DATA ACQUISITION 8 CN 0.885 16.50 ROBOTICS POWER INSTALLATION 841106 010237 C90K001 RB DATA ACQUISITION 6 CN 1.335 16.87 LOAD TEST ROBOT MONORAIL 841106 010238 C90h001 RB DATA ACQUISITION 2 CN 0.386 4.57 INSTALL HATCH CAMERA FOR ROBOTICS 841108 010253 C90K001 RB DATA ACQUISITION 1 CN 0.111 1.41 STAGE ROBOT INTO RB 841108 010254 C90K001 RB DATA ACQUISITION 3 CN 0,220 3.33 STAGE R000T FLUSH UNIT IN CTMT 841108 010255 C90K001 RB DATA ACQUISITION 3 CN 0.333 5.35 MOVE ROBOT MONORAIL 841109 010261 C90K001 RB DATA ACQUISITION 2 HP 0.425 4.57 VIDEO SURVEY / FLUSH ROBOT
  • 841109 010261 C90K001 RB DATA ACQUISITION 1 IC 0.045 1.13 VIDEO SURVEY / FLUSH ROBOT
  • 841109 010261 C90K001 RB DATA ACQUISITION 7 CN 1.783 16.07 VIDEO SURVEY / FLUSH ROBOT 841115 010296 C90K001 RB DATA ACQUISITION 7 CN 0.781 11.90 ST AGE ROBOT / REMOTE SUR VE Y
  • 841115 010296 C90K001 RB DATA ACQUISI110N 2 HP 0.278 3.52 STAGE ROBOT /RE MOTE SURVEY 841130 010377 C90K001 RB DATA ACQUISITION 1 AM 0.125 1.50 CABLE INSPECI!ON

DATE 022486 PAGE 73 DDS - ACTIVITY REPORT-REACTOR BUILDING DECONTAMINATION 286 D PNO. 72 PERS. DEPT. EXPOS. TIME .TMI-2 UNC: ...............IPTIONTASK DESCR..........................

  • RWP

.RWP .EXP TRCK. . CODE. REM .tt0URS ,......... E. N T R.................................. ACTIVITY

  • D A T E... NUMB.E.R. NUMBE.R.........................
  • 841130 010377 C90K001 RB DATA ACQUISITION 1 CN 0.I20 1.53 CABLE INSPECTION 1 HP 0.101 1.53 CADLE INSPECTION
  • 841130 010377 C90K001 RB DATA ACQUISITION 1 ES 0.103 1.48 CABLE INSPECTION
  • 841130 010377 C90K001 RB DATA ACQUISITION 1 HP 0.151 1.68 INSTALL & RETRIEVE TLDS

$850226 010988 C90K001 RB DATA ACQUISITION 1 CN 0.075 1.13 INSTALL & RETRIEVE TLDS .850226 010988 C90K001 RB DATA ACQUISITION 850320 011173 C90K001 RB DATA ACQUISITION 1 HP 0.055 0.85 REMOVE INSTRUMENTS FROM ROBOT = C90K001 .SUBIOTAL - EX.P TRCK NUMBER PERS ENTR 502 EXPOS REM 76.317000 TIME HOURS = 902.23000 l GRAND-TOTAL - 21526 PERS ENTR = . EXPOS REM 666.18600 TIME HOURS 60822.060 END REPORT s a @m e i

N.,c, O... 6 5 %c a A -. w. A > O-cO.. 55,0% t.Oa f No u -,A

t.,,0C m N.

BIBLIOGRAPHIC DATA SHEET NUREG/CR-4315, Vol. 2 , e 3 Tiftt AND 5ygfaTLg e atCtretNT S ACCT S$'ON Nuwet a Evaluation of Nuclear Facility Decommissioning Projects { hEiN fba Nt 2 $ Daf t atPOR T Cuwagt Tto l " '" Reactor Building gcontanination February 1986 6 sy t Om 5 7 oaf t REPOAT 155ut D MONTM vtA8 D. H. Doerge, R. L. i 'ller, K. S. Scotti May 1986 9 PROJECT. T A5n% ORE uhof Nuweta 8 6't&FOluiNG ORGANiz ATeON NAwf AND w lNG ADDat 55 isarwoe le Cears UNC Nuclear Industries F Decommissioning Programs epartment ' a "* "v"" " Fed /300-A/F27, 700 Area P. O. Box 490 Richland, WA 99352 FIN 87568 11 Sv0NSOmiNG ORGANIZ ATt0% Naut AND Malt NG ADO 5 nacNee le Coore tze Tvrt OF REPORT Division of Engineering Techno gy Office of Nuclear Regulatory Re arch Technical U. S. Nuclear Regulatory Commissi Washington, DC 20555 June 1, 1979 to March ')4 10M 13 SvWtivfNTaavNOTE5 is Ae5Tn ACT /200 weres er was This document summarizes information conc i decontamination of the Three Mile Island Unit 2 reactor building which was gr ly contaminated as a result of the loss of coolant accident experienced on March 28, 979. Data collected from activity reports, react tainment entry records, and other sources were placed in a computerized infor atio retrieval / manipulation system which permits extraction / manipulation of specifi data ich could be utilized in planning for recovery activities should a similar ident cur in a nuclear generating plant. The information is presented in both comp er outpu form and a manually assembled ,w.marization. This report contains only the man-hours ent and radia on exposure actually incurred during performance of tasks in radiation areas and does t include support activities outside of radiation areas. This report covers the perioc f activities from June 1, 1979 through March 29, 1985. i q i fi % tt v WORD 5 AND DOCUMENT ANALYSIS 1 t$o OtSCRIPTORS decontamination radiation exposure data acquisition 16 AvalbE8ttef v STaf tMENT IF SicumiTV CL A55se sCAf SON te NuwetR OF PAGt 5 "ifn'*c"T'as si fi ed un1imited is acuaif v ct A55.icAT.ON 2o Patct "linDassified 5 .a

UNITED STATES secci4L rouarw-ctass act NUCLEAR REGULATORY COMMISSION POSTME**p5 PAS s WASHINGTON, D.C. 20555 wasa e c PERMeT % G 67 OFFICIAL BUSINESS PENALTY FOR PRIVATE USE, $300 i i I}}