o MORTON THIOKOLINC.

l Huntsville Division

rxr,

~, ' _

a CONTROL NO. U-86-4477 QUALITY ASSURANCE PROGRAM FOR SHIPMENT OF RADIOACTIVE MATERIAL FOR COMPLIANCE WITH 10 CFR PART 71 May 28, 1986 Oa'/

+

John S.

Epps J. Kr pko Manager Manager Testing Department Sa fety 8606240250 860529 PDR ADOCK 07100435 C

PDR l

Huntsvice, Alabama 35807 7501 (205)882-8000

QUALITY ASSURANCE PROGRAM FOR SHIPMENT OF RADIOACTIVE MATERIALS FOR COMPLIANCE WITH 10 CFR PART 71

1.0 INTRODUCTION

1.1 Morton Thiokol, Inc., operates a radiographic inspection faci-lity in Building 7345 on Redstone Arsenal, AL, in accordance with NRC License 01-00856-02 and Sub-1334, and Army Permit P01-THD-01-01.

This facility uses encapsulated isotope sources of "special form" (10 CFR 71.4 and 71.75) as gamma sources and depleted uranium metal for shielding in a linear accele-rator X-ray machine.

Use of these radioactive materials is limited to Building 7345.

Transportation of these materials occurs only occasionally whenever an isotope source must be disposed of, replaced, inspected, modified or material con-taminated by a leaking source must be dispositioned.

On that occasion, the material is shipped to a source supplier or to a burial ground.

For shipment, the source material is packaged in a container which has a NRC Certification of Compliance (COC) (provided by a source supplier) or, for waste disposal, in a container complying with the applicable requirements (purchase for the occasion).

1.2 The purpose of this Quality Assurance Plan is to assure the safe shipment, both outgoing and incoming, of these radio-active materials in accordance with appropriate regulations.

It is written to assure that approved containers are used, that packaging in the containers is proper, instructions to all involved are proper and followed and that appropriate records are maintained.

This plan is to be supported by management and operating procedure as appropriate.

2.0 ORGANIZATION AND RESPONSIBILITIES 2.1 The final responsibility for the Quality Assurance Program for 10 CFR Part 71 rests with the management of Morton Thiokol, Inc., Huntsville Division, Huntsville, Alabama.

The line of authority in implementing duties is shown in Appendix A.

The assignment of specific duties is shown in Appendix B.

Since i

the Morton Thiokol facility is on Redstone Arsenal, by Army regulations (see Reference Appendix C), U.

S. Army personnel must inspect all incoming and outgoing shipments of radio-active materials.

For this reason, their duties are included in Appendix B.

)

)

i

1 ORGANIZATION AND RESPONSIBILITIES (Continued)

Page 2 2.2 Primary responsibility for the written procedures and train-ing to implement this plan and to assure that the latest regulations are implemented rests with the Group Supervisor of Radiographic Inspection.

Secondary responsibility to assure that the latest regulations are implemented rests with the Radiological Protection Officer.

Training, prior to engagement, for all QA functions is required according to written procedures.

QA program revisions will be made accord-ing to written procedures with management approval.

2.3 The Radiological Protection Officer shall. assure that all radioactive material shipping packages are designed and manu-factured under a QA program approved by the Nuclear Regulatory i

Commission.

This requirement will be satisfied by receiving a certification to this effect from the manufacturer.

l 3.0 DOCUMENT CONTROL All documents related to a specific shipping package will be controlled through the use of written procedures.

All docu-ment changes will be performed according to written procedures i

approved by management.

1 The Group Supervisor of Radiographic Inspection shall insure that all.QA functions are conducted in accordance with the latest applicable changes to these documents.

4.0 HANDLING, STORAGE AND SHIPPING Written safety procedures concerning the handling, storage, shipping of packages for certain special form radioactive material will be followed.

Shipments will not be made unless all tests, certifications, acceptances and final inspections have been completed.

Work instructions will be provided for handling, storage and shipping operations.

5.0 INSPECTION, TEST AND OPERATING STATUS Inspection, test and operating status of packaging for certain special form radioactive material will be indicated and con-trolled by written procedures.

Status will be indicated by tag, label, marking or log entry.

Status of nonconforming parts or packages will be positively maintained by written procedures.

INSPECTION, TEST AND OPERATING STATUS (Continued)

Page 3 Radiography personnel shall perform the regulatory required inspections and tests in accordance with written procedures.

The Group Supervisor of Radiographic Inspection shall ensure that these functions are performed.

6.0 QUALITY ASSURANCE RECORDS Records of package approvals (including references and draw-ings), procurement, inspections, tests, operating logs, audit results, personnel training and qualifications and records of shipments will be maintained.

Descriptions of equipment and written procedures will also be maintained.

These records will be maintained in accordance with written procedures.

The records will be identified and retrievable.

A list of these records, with their storage locations, will be maintained by the Group Supervisor of Radiographic Inspection.

7.0 AUDITS Established schedules of audits of the QA program will be performed using written check lists.

Results of audits will be maintained and reported to management.

Audit reports will be evaluated and deficient areas corrected.

The audits will be dependent on the safety significance of the activity being audited, but each activity will be audited at least once per year.

Audit reports will be maintained as part of the quality assurance records.

Members of the audit team shall have no responsibility in the activity being audited.

APPENDIX A 1

ORGANIZATION CHART - HUNTSVILLE DIVISION RADIOGRAPHY PROGRAM John D. Thirkill Vice President and General Manager I

I Finance and Quality Administration J. C.

Godsey C. L. Munk, Director Director I

I Material Safety Testing Department Department Department J.

S. Epps R.

J.

Presto E.

J. Krupko Manager Manager Manager Supervisory Management Control at this level and up.

Active Manage-ment Control established at Stores and Nondestructive this level and Distribution Testing Section down.

J. W. Tucker E.

J. Magnusson Chief Chief Radiological. Protection Radiographic Inspection Officer D. P. Aycock J. J. Robertson Group Supervisc-r n

n

.m,

APPENDIX B 1.

Primary DUTY ASSIGNMENTS 2.

Secondary DUTIES RESPONSIBILITIES MORTON THIOKOL, INC.

U.

S. ARMY Stores GS, Rad.

Chief Insp

& Dist.

Insp. or NDT RPO MICOM Eq.Mgt.

Section Radio-Section RPO Div. of grapher RASA

1. Training (for packaging, 1

2

)

inspection and tests

2. Initiating requests for 1

2 shipment

3. Assuring package (con-2 1

tainer) certification I

4. Wipe test of sources 1

2 (incoming and outgoing)

5. Inspection and tests of 1

2 2

containers (outgoing)

6. Packaging 1

2 2

7. Labeling 1

2 1

8.

Inspection and tests 1

2 2

1 of packaging (incoming and outgoing)

9. Document Control -

2 1

2 2

1 inspection and tests

10. Arranging for shipping 3

services

11. Requesting Redstone 1

Arsenal support

12. Document Control -

1 shipping

13. Auditing 2

1

14. Inspect vehicles and 1

inform driver M

APPENDIX C REFERENCES 1.

Nuclear Regulatory Commission Material License No. 01-00856-02 Amendment No. 28.

2.

Nuclear Regulatory Commission Material License No. Sub-1334.

3.

Army Regulation 385-11, Ionizing Radiation Protection, 1 May 1980.

4.

Army MICOM Regulation 75-3, Control of Hazardous Type Materials Incident to Transportation, 6 January 1986.

5.

Army MICOM Regulation 385-20 (J), Radiation Protection Program, 22 June 1983.

6.

Army Radioactive Material Permit No. P01-THD-01-01.

7.

Code of Federal Regulations, Title 10, Chapter 1, United States Regulatory Commission.

8.

Bureau of Explosives' Tariff No. BOE-6000.

9.

Morton Thiokol, Inc., Huntsville Division, Management Procedure No. 4.100.01, 2 June 1972, Shipment of Hazardous Materials.

- _.