Babcock & Wilcox noei, r
, oivi.i a McDermott company 3315 Old Forest Road P.O. Box 10935 Lynchburg,VA 24506-0935 i
(804) 385-2000 April 2, 1987
'JHT/87-068 Mr. Carl Berlinger, Chief Reactor Systems Branch Division of Pressurized Water Reactor Licensing - A Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 i
Subject:
ECCS Application of the FOAM 2 Computer Program for Licensing _ Catawba and McGuire Reloads a===
-e j
Dear Mr. Berlinger:
This letter is to confirm B&W's intent to use the FOAM 2 computer 1
1 program as part of its ECCS Evaluation Model for Westinghouse designed plants.
Specifically, B&W plans to use FOAM 2 for the computation of core swell or mixture level' during small break LOCA.
Documentation of the method of use, input model, and options selection will be ' provided in B&W's Evaluation Model Topical Report, which is presently scheduled for submittal to the NRC by 12/31/87.
The NRC has reviewed (Dr. Summer Sun)2,3 and approved FOAM 2 for 4
application to B&W designed plants.
The Safety Evaluation-4 Report (SER), which imposes certain limits on the range of application of the code, is under review at B&W.
B&W expects to request an expansion of the range of application for the B&W plant Evaluation Model.
The application within the Westinghouse design will also require some range expansion.
B&W does not believe that a detailed review of FOAM 2 is required.
- However, a
review as to the applicability of the code to Westinghouse designed plants is in order.
Such a review may 5
i commence now.
B&W has requested that this review be completed by July 1, 1988.
I h h
Lp 8704130732 870402 PDR ADOCK 05000369 gC I 6\\
P PDR Q
sr#
l We hope that the ab'ove information will assist you in planning your work with regards to this matter and other_related matters.
If there are any questions or if additional information 'is required please contact C. F. McPhatter at (804)385-2401.
Very truly yours,
. H. Taylo Manager, Licensing Services.
cc:
R.
B. Borsum T.
L.
Baldwin R. J. Schomaker 1
r E
e
7
/
REFERENCES 1.
BAW-10155, " FOAM 2 - Computer Program to Calculate Core Swell Level and Mass Flow Rate During Small Break LOCA," November 1982.
2.
Letter from J. H. Taylor (B&W) to C.
O. Thomas (NRC),
" Transmittal of Responses to a Round of Questions from the NRC on the Topical Report FOAM 2, BAW-10155," 15 August 1984.
3.
Letter from R. J. Schomaker (B&W) to S. Sun (NRC),
" Justification for Use of FOAM 2 (BAW-10155) at Pressure Up to 2200 psig," 12 September 1986.
4.
Letter from D. M. Crutchfield (NRC) to J. H. Taylor (B&W),
" Acceptance for Referencing Topical Report BAW-10155, FOAM 2 - Computer Program to Calculate Core SwelliLevel and Mass Flow Rate During Small Break LOCA," 4 November 1986.
5.
Letter from J. H. Taylor (B&W) to Carl Berlinger (NRC),
"ECCS Methodology for Licensing Catawba and McGuire Reloads," JHT/86-166, July 14, 1986.
(