n Director, Office of Resource Management March Monthly Operating Report April 8,

1986 ATTACHMENT I AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50/395 UNIT V.

C.

SUMMER __I DATE 04/15/86 COMPLETED BY G.

A.

Loignon TELEPHONE (803) 345-5209 MONTH MARCH 1986 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1.

882 17.

886 2.

883 18.

894 3.

882 19.

894 4.

883 20.

894 5.

882 21.

893 6.

883 22.

893 7.

883

23..

895 8.

884 24 894 9.

885 25.

895 10.

884 26.

895 11.

885 27.

896 12.

885 28.

896 13.

885 29.

896 14.

885 30, 886 15.

885 31.

896 16.

885 B606230040 860331 PDR ADOCK 05000395 R

PDR 1

th

~

e Director, Office of Resource Management March Monthly Operating Report Page 2 April 8, 1986 ATTACHMENT II OPERATING DATA REPORT DOCKET No.

50/395 UNIT V. C. SUMMER I DATE 04/15/86 COMPLETED BY G. A. Loigr.ce TELEPHONE (803) 345-5209 OPERATING STATUS

1. Reporting Period:

MARCH 1986 Gross Hours in Reporting Period:

744

2. Currently Authorized Power Level (MWt):

2775 Max. Depend. Capacity (MWe-Ne t) :

885 Design Electrical Rating (MWe-Net):

900

3. Power Level to which restricted (If Any)(MWe-Net): N/A
4. Reasons for Restrictions (If Any): N/A THIS MON H YR TO DATE CUMULATIVE
5. Number of Hours Reactor Was Critical 744.0 2,116.7 14,110.0
6. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
7. Hours Generator on Line 744.0 2,102.9 13,743.2
8. Unit Reserve Shutdown Hours 0.0 0.0 0.0
9. Gross Thermal Energy Generated (MWH) 2,061,270 5,738,808 35,576,374
10. Gross Elec trical Energy Generated (MWH) 687,820 1,917,580 11,848,233
11. Net Electrical Energy Generated (MWH) 661,009 1,839,136 11,261,768
12. Reactor Service Factor 100.0 98.0 71.6
13. Reactor Availability Factor 100.0 98.0 71.6
14. Unit Service Factor 100.0 97.4 69.7
15. Unit Availability Factor 100.0 97.4 69.7
16. Unit Capacity Factor (Using MDC) 100.4 96.2 64.6
17. Unit Capacity Factor (Using Design MWe) 98.7 94.6 63.5
18. Unit Forced Outage Rate 0.0 2.6 7.5
19. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

NONE

20. If Shut Down at End of Report Period, Estimated Date of Startup:

N/A

21. Units in Test Status (Prior to Commerical Operation):

FORECAST ACHIEVED Initial Criticality N/A 10-22-82 Initial Electricity

__N/A 11-16-82 Commercial Operation F/A 01-01-84

o" Director, Office of Resource Management March Monthly Operating Report Pcge 3 April 8,

1986 ATTACHMENT III UNIT SHUTDOWNS AND POWER REDUCTION 5 DOCKET NO.

50/395 UNIT V.

C.

SUMMER I DATE 04715/86 COMPLETED BY G.

A. Loignon _

TELEPHONE (803) 345-5209 (1)

METHOD OF (2)

TYPE SHUTTING DOWN F: FORCED DURATION THE REACTOR OR CORRECTIVE ACTIONS /

NO.

DATE S: SCHEDULED (HOURS)

REASON REDUCING POWER COMMENTS None

?

e Director, Office of Resource Management March Monthly Operating Report Page 4 April 8,

1986 i

l

. ATTACHMENT IV NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE i

I On March 1, 1986, the Virgil C.

Summer Nuclear Station, Unit I was j

operating at approximately 100 percent power.

l On March 31, 1986, the plant was operating at approximately 100

{

percent power.

4 4

j i

o i

i t

i I

4 4

1 l

}

4 i

I 4

I g*

South Carolina Electric & Gas Company Dan A.Nauman P.O. Box 764 Vice President i

Columbia, SC 29218 Nuclear Operations (803) 748 4513 SCE&G

.sen a w, April 8,

1986 Director, Office of Resource Management U.S.

Nuclear Regulatory Commission MNBB 7602 Washington, DC 20555 ATTN:

Mr. Learned W.

Barry

SUBJECT:

Virgil C.

Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 March Monthly Operating Report Dea r Mr. Barry:

Please find enclosed the March 1986 Monthly Operating Report for the Virgil C.

Summer Nuclear Station Unit No.

1.

This submittal is made in accordance with the requirements of Technical Specification 6.9.1.10.

l If there are any questions, please call us at your convenience.

ery t uYy'yours, I

3 -

D.

N man T

RMF: GAL: DAN / led Attachment c:

V.

C.

Summer R.

M.

Campbell O.

W.

Dixon, Jr./T.

C.

Nichols, Jr.

K.

E.

Nodland E.

H.

Crews, Jr.

R.

A.

Stough E.

C.

Roberts G.

O.

Percival J.

G.

Connelly, Jr.

R.

L.

Prevatte W.

A.

Williams, Jr.

J.

B.

Knotts, Jr.

H.

R.

Denton INPO Records Center J.

Ncison Grace ANI Library Group Managers L.

N.

Carter O.

S.

Bradham R.

E.

Rainear D.

R.

Moore S.

D.

Hogge C.

A.

Price NPCF C.

L.

Ligon (NSRC)

File gp f *

\\

I

. _.