ML20206D524

From kanterella
Jump to navigation Jump to search
Forwards SER Accepting BWRVIP-25 Rept BWRVIP Vessel & Internals Project,Bwr Core Plate Insp & Flaw Evaluation Guideline, TR-107284 Dtd Dec 1996 for Insp & Flaw Evaluation of Subject safety-related RPV
ML20206D524
Person / Time
Issue date: 04/28/1999
From: Strosnider J
NRC (Affiliation Not Assigned)
To: Terry C
NIAGARA MOHAWK POWER CORP.
Shared Package
ML20206D527 List:
References
TAC-M97802, NUDOCS 9905040142
Download: ML20206D524 (5)


Text

,

WE:q p k UNITED STATES d

j t

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. acce64001

\*****/ April 28, 1999 )

i i

Carl Terry, BWRVIP Chairman '

Niagara Mohawk Power Company Post Office Box 63 Lycoming, NY 13093

SUBJECT:

SAFETY EVALUATION OF THE *BWRVIP VESSEL AND INTERNALS PROJECT,"BWR VESSEL AND INTERNALS PROJECT, BWR CORE PLATE INSPECTION AND FLAW EVALUATION GUIDELINE (BWRVIP 25)," EPRI REPORT TR 107284, DECEMBER 1996 (TAC NO. M97802) .,

Dear Mr. Terry,

l The NRC staff has completed its review of the Electric Power Research Institute (EPRI) proprietary report TR-107284, *BWR Vessel and Intemals Project, BWR Core Plate inspection and Flaw Evaluation Guideline (BWRVIP-25)," Decernber 1996. This report was submitted by letter dated December 27,1996, and_ supplemented by a letter dated December 19,1997, which was in response to the staff's request for additional information, dated March 14,1997.

The BWRVIP 25 report provides generic guidelines intended to present the appropriate inspection recommendations to assure safety function integritj of the subject safety-related l RPV intemal components. It also provides design information on the core plate, geometries, I weld locations, and potential failure locations for the several categories of boiling water l reactors (BWR/2 through BWR/6). t l

l The NRC staff has reviewed the BWRVIP-25 report and finds,in the enclosed Safety  ;

l Evaluation (SE), that the guidance of the BWRVIP 25 report is acceptable for inspection and i flaw evaluation of the subject safety-related RPV intemal components, except where the staff's 4 conclusions differ from the BWRVIP's, as discussed in the enclosed SE. The staff has concluded that licensee implementation of the guidelines in the BWRVIP-25 report will provide an acceptable level of quality for inspection and flaw evaluation, with modifications to address the staff's conclusions in the enclosed SE, of the safety-related components addressed.

The staff requests that the BWRVIP review and resolve the issues raised in the enclosed SE, and incorporate the staff's conclusions into the revised BWRVIP-25 report. Please inform the staff within 90 days of the date of this letter as to your proposed actions and schedule for such revisions.

[I 050p O 8

~

"fbq C PDR ,

'tf

(( ]. &

Cari Terry l Please contact C. E. (Gene) Carpenter, Jr., of my staff at (301) 415-2169 if you have any further questions regarding this subject.

Sincerely, Jack R. Strosnider, Director Division of Engineering Office of Nuclear Reactor Regulation

Enclosure:

As stated cc: See next page DISTRIBUTION:

EMCB R/F GHolahan MEMayfiled WLanning, R1 PUBLIC KAKavanagh EHackett BMallet, R2 File Center JRRajan TYChang JGrobe, R3 ACRS gjcgmp AHowell, R4 DOCUMENT NAME: G:\BWRVIPWIP25SER INDICATE IN BOX:"C" COPY W/O ATTACHMENTENCLOSURE,"E" COPY W/ATTENCL. *N".NO COPY M 7 oFACE EMCB:DE b SLS:EMCB:DE f BC:EMCB:DE j n BC:EMEB:DE NAME CECarpenter , ,A RAHermannd WHBatemahh Elmbro N DATE 03/24/1999 03/31/1999 04/ b 11999 04/ 7 /1999 OFRCE BC:SBXB:DSSA DD:DE 7 D:DE hx/

NAME JWerr RHW JRStrosni DATE 04/ /1999 04/ II/1999 04/28 /199 OFFICIAL RECORD COPY l

l

/i

, Carl Terry l Please contact C. E. (Gene) Carpenter, Jr., of my staff at (301) 415-2169 if you have any further questions regarding this subject.  ;

Sincerely, Jack R. Strosnider, Director Division of Engineering Office of Nuclear Reactor Regulation ,

l

Enclosure:

As stated I

cc: See next page l

l DISTRIBUTION:

EMCB R/F GHolahan MEMayfiled WLanning, R1 PUBLIC KAKavanagh EHackett BMallet, R2 File Centor JRRajan TYChang JGrobe, R3 ACRS AHowell, R4 3

DOCUMENT NAME: G:\BWRVIPWIP25SER d" lNDICATE IN BOX:"C"mCOPY W/O ATTACHMENTmCOPY / ENCLOSURE *E"p COPY W/ATT/ ENCL,"N"mNO OFFICE EMCB:DE SLS:EMCB:DE I kBC:EMCB:DE (A)BC:EMEB:DE NAME CECarpenter/ , RAHern#O W KAManoly DATE 3 / k/99 ~3 / 3l /99 / /99 / /99 OFFICE SRXB:DSSA DD:DE D:DE NAME JWermiel RHWessman JRStrosnider DATE / /99 / /99 / /99 OFFICIAL RECORD COPY l

(

l

I'

,a

  • i I

Carl Terry 2- 1 Please contact C. E. (Gene) Carpenter, Jr., of my staff at (301) 415-2169 if you have any further questions regarding this subject.

Sincerely, W 4t Jack R. Strosnider, Director Division of Engineering Office of Nuclear Reactor Regulation

Enclosure:

As stated cc: See next page 0

I .

cc:

Karl W. Singer, Executive Chair Steve Lewis, Technical Chairman BWRVIP Assessment Task BWRVIP Assessment Task Tennessee Valley Authority Entergy PO Box 2000 P. O. Box 756 Decaltur, AL 35602-2000 Waterloo Road Port Gibson, MS 39150 Bill Eaton, Executive Chair inspection Committee Carl Larsen, Technical Chairman Entergy Operations, Inc. BWRVIP Inspection Task PO Box 756, Waterloo Rd Yankee Atomic Port Gibson, MS 39150-0756 580 Main Street Bolton, MA 01740 H. Lewis Sumner, Executive Chairman BWRVIP Mitigation Task John Wilson, Technical Chairman .

Southem Nuclear Operating Co. BWRVIP Mitigation Task WS BIN B051, PO Box 1295 Clinton Power Station, WC T-31C 40 invemess Center Parkway P.O. Box 678 Birmingharn, AL 35201 Clinton,IL 61727 Harry P. Salmon, Executive Chairman Vaughn Wagoner, Technical Chairman BWRVIP Integration Task BWRVIP Integration Task New York Power Authority Carolina Power & Light Company 123 Main St., WS 11 D One Hannover Square 9C1 White Plains, NY 10601-3104 P.O. Box 1551 Raleigh, NC 27612 George T. Jones, Executive Chair BWRVIP Repair Task Bruce McLeod, Technical Chairman Pennsylvania Power & Light, Inc. BWRVIP Repair Task WS GEN A 61 Southem Nuclear Operating Co.

2 N 9* Street Post Office Box 1295 Allentown, PA 18101-1139 40 inverness Center Parkway Birmingham, AL 35201 Robert Carter, EPRI BWRVIP Assessment Manager Warren Bilanin, EPRI BWRVIP EPRI NDE Center Integration Manager P. O. Box 217097 Raj Pathania, EPRI BWRVIP 1300 W. T. Harris Blvd. Mitigation Manager Charlotte, NC 28221 Ken Wolfe, EPRI BWRVIP Repair Manager Greg Selby, EPRI BWRVIP Electric Power Research Institute Inspection Manager P. O. Box 10412 EPRI NDE Center 3412 Hillview Ave.

P. O. Box 217097 Palo Alto, CA 94303 1300 W. T. Harris Blvd.

Charlotte, NC 28221 James P. Pelletier, BWRVIP Liaison to EPRI Nuclear Power Council Joe Hagan, BWRVIP Vice Chairman Nebraska Public Power District PEPCO Energy Co. 1200 Prospect Avenue MC 82C-3 PO Box 98 965 Chesterbrook Blvd Brownville, NE 68321-0098 Wayne, PA 19807-5691

_ _ _ _ _ _ _ _