ML20206D096
| ML20206D096 | |
| Person / Time | |
|---|---|
| Site: | Oregon State University |
| Issue date: | 11/07/1988 |
| From: | Andrea Johnson Oregon State University, CORVALLIS, OR |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| NUDOCS 8811160535 | |
| Download: ML20206D096 (2) | |
Text
_ _ _ _ _ _ _ _ _ _ _ _ _ _
'. 1,.
=
U v isity comme, oregon erasi no= m.,m Pediation Center J
November 7,1988 Document Control Desk U.S. Nuclear Regulatory Comission Washington, D. C. 20555
Reference:
Oregon State University TRIGA Reactor (OSTR),
Docket No. 50-243, License No. R-106
Subject:
Request for a Change to OSTR Technical Specification 3.1, and Corrections to Technical Specifications 2.1 and 6.4 Gentlemen:
Oregon State University would like to request a change to the wording of OSTR Technical Specification 3.1.
The specification currently reads:
"The reactor power level shall not exceed 1.0 megawatt under any condition of operation." We would like this wording to be amended to read:
"The reactor power level shall not intentionally be raised above 1.0 megawatt, except for pulsing operations." Inis amendment will clarify the original intent of the specification and is consistent with the wo. ding in the technical specifications of other TRIGA research reactors.
In addition to the above change, there are two errors in our current Technical Specifications which we would like to request you consider chang-ing. First, Technical Specification 2.1.b states that:
"The tem in a standard TRIGA fuel element shall not exceed 1380'F (1000*C)perature under any condition of operation." The temperature 1380'F is a typographical error in the conversion from 1000'C.
It should be 1830'F.
The second error is in Technical Specification 6.4.b where it states that reports "shall be submitted to the Reactor Safety Comittee for review."
The name of this comittee at OSU is the Reactor Operations Comittee.
The OSU comittee is given the correct title in the other parts of the Technical Specifications such as 6.1, 6.2, 6.3, and 6.5.
Therefore, we would like to request that 6.4.b be changed to indicate Reactor Operations Comittee instead of Reactor Safety Comittee.
8811160535 881107 PDR ADOCK 05000243 P
PDC Oregon State Unhorsityis an A"smawe Act.on/ Equal Opportun4 Empher
_ _ _ _ _ _ ___ A
2 The purpose of the three requested changes is to remove the possi.
bility of confusion or misunderstanding which might result from the current wording.
Should there be a need for further clarification or justification, or should more information be required, please let me know.
Yours sincerely, 1
A. G J.hnson Direc I
AGJ:jrs/1-019 cc:
Standardization and Non-Power Reactor Project Directorate, Division of Reactor Projects Ill, IV, Y and Special Projects. Office of Nuclear ReJctor Projects Washington, D.C. 20555 ATTN:
Mr. Al Adams Regional Administrator, USNRC, Region V Director,1regon Department of Energy Salem, Oregon Prof. S.E. Binney, Chairman, Reactor Operations Comittee Prof. B. Dodd, Reactor Administrator Prof. J.F. Higginbotham, Senior Health Physicist Mr. T.V. Anderson, Reactor Supervisor Mr. D.S. Pratt, Health Physicist STATE OF OREGON
)
)ss COUNTY OF BENTON )
A. G. Johnsen, being first duly sworn on oath, deposes and says that he has affixed his signature to the letter above in his official capacity as Director, Oregon State b iversity Radiation Center; that in accordance with the provihions of Part 50. Chapter 1. Title 10 of the Code of Federal Regulations, he is attaching this affidavit; that the facts set forth in the within letter are true to his t information and belief.
W.._.
.GMnl in" ""
Director i
Subscribed and sworn to before me, a,'otary Public, in and,for the County of Benton, State of Oregon, this *(
W ay of bx m_fw s A.D., 1987.
~
L e
An N
!fYb Notary Fublic of Oreg6n My Codimissidn Expires