_ _ _ _.. _ _.
'7/-05'a9 RLTURNTOhhdl((
M ET */
.HE M TESTING LABORATORIE5, OF LITAH, INC.309,W Cir e.gIo C
~,,
/,
/
i..
~.t
,/.
\\,
l lb b^
RECDVED c
%]A ',.UlU33>
NOV 0 71%s [r::b.vember a,
t 1988 i: m. w.... :
(
~,.
- //
N.
I
- 7
.g g x '_
-g e
,3.,
,Ac
.I u,s,
', r Lirs 4
0.','-..,
) *; i,,. ; 'e M
/)Tjg&. 4,%CfD1-terIne Dona 1 d,j/, k, M,. Q
/
i I
Mr.
d
{
Transportation Certiric hian.. Brunch U,S.
Nu s ca r hett u l a,7 ry Commission l
7920 Nirfolk Avenue f
Washington, D.
C.
20555 l
l Re:
Quality Assurance Program f or hadionet ive MTterial Package No.
0509
Dear Mr. MacDonsld:
j Pr.r your letter of October 20 1988, we are requesting that i
Me t -( nem 's Quality Assurance Program. No. 0509, be renewed.
Plrase find enclosed a copy of our program and. cheek in the I
amount of $150.00.
l j
Sincere 1y, J
MET-Cl)b!TES'ING LABORATORIES i-l d
14
/d 8-
~
f..
Weyne llansen Pres ident / Al t errust e Radiation Safety Officer 1
tne1asure S k il / s h
(
i
(
I
'),gy
} 's - l
^T ggi1160 % (i)Ihfi.209
'W D $ *'/
) t f
l'Nd pDR AD i
c j
lier
(}
i
,, n,;
\\\\
ig l
e
/ :......
a_ sc7
M ET
- C H E M 3ee weet Gewp Avenue sets we city, Utah 04115 teoil 4074001 TESTING LABORATORIPS, OF UTAH. INC.
l l
l.
I I
i QUALITY ASSURANCE PROGRAM l
MET-CHEM TESTING LABORATORIES, GF UTAll, INC.
i 10CFR71 QA PROGRAM i
l l
i I
I l
l
/
l PREPARED BY A N t fi M,./ _ fAI.,,'
I j
DODGLAS d'.'
JOHNSTON I
C rporate Radi tion Safety Officer l
[l dEh_
APPROVED BY e
N.
M 6E HANSEN l
/
President i
i l
l DATE JANUARY 29. 1986 l
i l
)
21J.,.1 ) !
~
of l
1
~ - - _.
t I
MFmT
- CHE TESTING LABORATORIES. OF UTAH. INC.
I 35D West Gregeon Avenvo Sett Late City, Lttah 04115 (D013 407 0001 h
i 1.0 ORGAN [7ATION
(
l 1.1 The final responsibility for the Quality Assurance Pro-gram for Part il requirements rests with Met-Chem Test-l ing Laboratories, of Utah. Inc.
1.2 Design and fabrication shall not be conducted under this Quality Assurance Program.
The Radiation Safety Officer i
in designated the responsible individual for the Part 71 1
quality assurance requirements.
1.3 The Radiation Safety Officer is responsible for overall administration of the program, training and certifica-tion, document centrol and auditing.
f 1.4 The radiographers are responsible for handlin'
- storing, I
shipping, inspection, test and operating a+
.4 and record keeping.
2.0 g'A1. TTY ASST'RANCE PROGRAM 2.1 The management of Met-Chem Testing Laboratories, of Utah. Inc.
establishes and imr'.ements this Qaality Assurance Program.
Training, p ior to engagement, for all quality assurance functions a required according to i
written procedures.
Quality Assi.rance Program revisions will be made according to written,)rocedur9s with man-l asement approval.
The Quality Assurance Program will ensure that all defined Quality Assurance Procedures, engineering procedures and specific provistors of the package design approval are satisfitd.
The Quality Assurance Program utli emphasize control of the charac-I teristics of the pr.ckage which are critical to safety, 2.2 The Radiation Safety Officer shall assure that all radioactive material shipping packages are designed and manufactured under a Quality Assurance Program approved l
by the Nuclear Regulatory Commission for all packages designed or manufactured after January 1, 1979.
This
{
requirement shall be satisfied by receiving a certifica-tion to this effect frcm the manufseturer.
l o
l l
l l
l
...a.
,. ac tui 2 or ies,.
eQ E:"
TESTING LABORATOR!ES. OF UTAH INC.
t h
309 West Gregson Avenue Sett Leme City, Utah 04i 15 (001) 407 0001 l
4 3.0 Doct'MFNT c0NTROL 3.1 All docut.3nts related to a specific shipping package will be controlled through the use of written proced-l I
ures.
All document changes will be performed accord-d ing to nritten procedures approved by management.
3.0 The Radiation Safety Officer shall ensure that all qual-I, ity assurance functions are conducted in accordance with the 1stest applicable changes to these documents.
4.0
}{ ANDI T NG, STORAGF AND SHIPPING 4.1 Written safety procedures concerning the handling, stor-age and shipping of packages for certain special form radioactive mat erial will be followed.
Shipments will l
not be made unless all tests, certifications, necept-ances and final inspections have been completed.
Work instructions will be provided for handling, storage and
)
shipping operations.
4.0 Radiography personnel shall perfctm the critical handl-i ing, storage and shipping operations.
l 5.0 TNSpFrTION, TFST AND OpFRATING ST ATt'S l
l 5.1 Inspection, test and operating status of packages for l
certain special torm radioactive material will be in-dicated and cont rolled by written ',rocedures.
Status will be indicated by tag, label, merking or log entry.
Status of non-conforming parts or packages will be positively maintained by written procedures.
5.2 Radiography personnel shall perform the regulatory re-quired inspections and test in accordance with written procedures.
The Radiation safety officer shall ensure i
that these functions are performed.
C.0 Qt'Al TTY ASST'R ANCF RFrORD9 6.1 Records of package approvals (including references and drawings), procurements, inspections, tests, operating f
i l
1 10CFR71 OA PROGFW3 Pace 3 of
MET
- CHE TESTING LABORATORIES. OF UTAH INC.
3SD West Gewgson Avenue Ga4 Lawe City. Utah 04 i 15 (001) <107 0001 logo, audit results, personnel training and qualifica-tions and records of shipments will be maintained.
De-scriptions of equ4,pment and written procedures will also be maintained.
6.1.1 The records will be maintained in accordance with a urttten procedure.
6.1.2 The records will be identified and retrievable.
C.I.3 The Radiation Safety Officer will maintain a list of the records and their storage location, 1
7.0 At'DITS 1
.1 Established schedule of audits of the Qurlity Assurance l
l Program will be performed using written check lists.
l Results of audits will be maintained. Audit reports will be evaluated and deficient areas corrected.
The audits will be dependent of the safety significance of the activity being audited, but each activity will be audit-ed at least once a year.
Audit reports will be mnin-tained as part o# the quality assurance records.
Mem-bers of the audit ceam shall have no rosyonsibility in the activity being audited.
b4 h D-N RA 1AJON Sp.TY OFTICEh I
1
. ara'. QA PROGFxt Page 4 of 4
__________J
s DOCKET NC.
~O O CONTROL NO.
F/O7 DATE OF 000. _ oremhec 5 /9FM DATE FCV0. I hhA?lXr! Y l$kb
/
FCUT -. _
P6A --. d L FCAF _. _
LP0i< ____ _.,
I& E FsEF.
SAFECuiaDS _- _
/
F')TC
/..
OTHER i
04J[//[ -
IHil!A:. _
0' i
e