ML20206A301

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re 880728 Application for Renewal of Model Gphs Package.Requests Response within 30 Days of Ltr
ML20206A301
Person / Time
Site: 07109510
Issue date: 11/07/1988
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Mccallum E
ENERGY, DEPT. OF
References
NUDOCS 8811150047
Download: ML20206A301 (2)


Text

. _ - _.. _ _ _ _ _ _ _

4

.i 1

1 NOV 0 71988 i

SGTB:EPE I

71 9510 i

i 1

U.S. Department of Energy i

Mr. E. McCallum DP.4 l

Washington, DC 20545 Gentlemen:-

a 3

This refers to your application dated July 28, 1988, requestir.g renewal for i

the Model No. GPHS package.

In connection with our review, we need the information identified in the enclo.

sure to this letter, t

L

/ lease advise us within 30 days from the date of this letter when this informa.

tion will be provided.

If you have any questions regarding this matter, we would i

be pleased to meet with you and your staff.

Sincerely, M

i i

j Charles E. MacDonald. Chief i

Transportation Branch Division of $afeguards l

{

and Transportation, NMSS 1

i l

Enclosure:

L j

As stated j

j t

DISTRIBUTION:

I l

O N EFEaston l

PDR CEWilliams r

I i

Region (II)

HWLee NMSS r/f SGTB r/f

[

l l

l GS11150047 881107 l

l POR ADOCK C/109510 C

PDC 1

j

/>

l 5GTep. :5GT (...:5GT5....tf.s..:.................... )

i 0FC: 50T03g:5G15C.dt:

L.

.c Ob f

i NME:EPEast n :CNtindner:CEWilliams:RChappell:CMacj6nald:

1

'I '

ll 0/88 : /// 8/88

/

ll /448: a/it/88 :

l DATE: II/3 /88 j

OFFICIAL RECORD COPY

7

.s U.S. Department of Enert2y Mocel No. GPH5 i

Doctet No. 71-9310 j

Revision 1 NOV e 1 Itse Enc 1 to Itr dtd:

i t

Operating Procedures l

Item 5 on page 7-3 states that the container is to be closed without the I

(0-ring)sealinplace. This is contrary to the discussion on page 1-6 and to the details on drawing AYE 880288. Please revise the application to correct this discrepancy.

f r

Maintenance Program If 0 rings are used to seal the GHPS shipping container specify the replace-ment schedule for the 0-ring seals, I

i i

f I

l 4

i i

.: