Forwards Reactor Containment Bldg Integrated Leakage Rate Test,Types A,B & C Periodic Test, Per 10CFR50,App J
ML20205T316
Person / Time
Site: Surry 
Issue date: 03/30/1987
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20205T319 List:
References
87-114, NUDOCS 8704070265
Download: ML20205T316 (1)


Text

-. _ _

10 CFR 50 App. J VINGINIA 15LECTRIC AND POWER COMPANY RzcuxoNn,VIHOINIA 20261 y,g gy m,,

March 30, 1987 VarE PEERIDENT NtJCLEAm OPERATIONS U. S. Nuclear Regulatory Commission Serial No.87-114 Attention: Document Control Desk N0/ETS:vlh Washington, D.C.

20555 Docket No.

50-281 License No. DPR-37 Gentlemen:

_ VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT NO. 2 REACTOR CONTAINNENT BUILDING INTEGRATED LEAK RATE TEST

)

Pursuant to 10 CFR 50, Appendix J V.B.1, Virginia Electric and Power Company (Virginia Power) is submitting the Integrated Leakage Rate Test Report for Surry Unit No. 2, dated November 1986.

If you have any questions concerning this matter, please do not hesitate to call.

Very truly yours, 7

()W.L. Stewart Attachment cc:

U. S. Nuclear Regulatory Commission 101 Marietta Street, N. W.

Suite 2900 Atlanta, CA 30323 Mr. W. E. Holland NRC Senior Resident Inspector Surry Power Station l

8704070265 870330 PDR ADOCK 05000281 p

PDR 0 k

_/