'o UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

g i

WASMNGTON, D. C. 20666 April 2, 1987 Docket Nos. 99900762/87-01 and 99901018/87-01 Nuclear Energy Services ATTN:

Mr. William J. Manion President Shelter Rock Road Danbury, Connecticut 06810 Gentlemen:

This refers to the inspection conducted by Ms. C. Abbate and Mr. P. Milano of this office on February 3-4, 1987, of your office in Danbury, Connecticut and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.

This inspection was conducted as a result of allegations the Nuclear Regulatory Commission (NRC) received concerning the use of uncertified welders and possible falsification of welding records at the Nuclear Energy Services (NES)-Selamco facility in Greensboro, North Carolina between September 1982 and January 1983.

The welding and records in question involved the fabrication of high density fuel storace racks (FSR) fnr a number of plants and the reactor cavity pool seal (RCPS)forConnecticutYankee.

Two of the nine allegations were substantiated in that uncertified welders per-formed work on FSRs and the RCPS, and welder certification practices were not in accordance with ASME Section IX requirements. These two areas were identi-fied by NES-Selamco in 1983 and corrective action was taken at that time (see NES-Selamco responte to the allegations - Appendix B of report). The documen-tation regarding the corrective action was reviewed during the inspection.

NES-Selamco was closed in 1986 by the parent company NES and the records trans-ferred to the NES Danbury, Connecticut office where this inspection took place.

The records which were examined during the inspection and the specific findings are discussed in the enclosed report.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Roon.

8704060344 870402 PDR GA999 ENONEs1 99900762 PDR i

I

(

Nuclear Energy Services April 2, 1987 Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

7 Sincerely,

/

Ellis W. Merschoff ting Chief Vendor Program Bra. h Division of Quality Assurance, Vendor and Technical Training Center Programs Office.of Inspection and Enforcement

Enclosures:

1.

Appendix A-Inspection Report No. 99900762/87-01 2.

Appendix B-NES Selamco Response to the Allegations 3.

Appendix C-Inspection Data Sheets (2 pages) cc w/ enclosures:

Carolina Power 1. Light Company ATTN: Mr. E. E. Utley, Senior Vice President Power Supply and Engineering and Construction Post Office Box 1551 Raleigh, North Carolina 27602 Duquesne Light Company ATTN: Mr. J. J. Carey, Vice President Nuclear Group Post Office Box 4 Shippingport, Pennsylvania 15077 Connecticut Yankee Atomic Power Company ATTN: Mr. J. F. Opeka, Senior Vice President Nuclear Engineering and Operations Group Post Office Box 270 Hartford, Connecticut 06101 Portland General Electric Company ATTN: Mr. William J. Lindblad President 121 S. W. Salmon Street Portland, Oregon 97204 Stone and Webster l

ATTN: Mr. R. B. Kelly, Vice President i

Quality Assurance Post Office Box 2325 Boston, Massachusetts 02107 Virginia Power Company ATTN: Mr. W. L. Stewart, President Nuclear Operations Post Office Box 26666 Richmond, Virginia 23261

4:.

Nuclear Energy Services-April 2, 1987

.1

', DISTRIBUTION

<_.seme*YH9tg VPB Reading DQAVT Reading JTaylor-

.BGrimes HMiller EMerschoff JStone CAbbate (2)

PMilano LParker(2)

BZalcman JPetrosino

  • See previous page for concurrences.

VPB:DQAVT ASC/VPB:DQAVT B:00AVT CAbbate:tt*

JStone*

rschoff 03/30/87 03/30/87 4 /&/87 1

}

t

~

Nuclear Energy Services April 2, 1987 DISTRIBUTION:

RIDS Code IE:09 VPB Reading f

DQAVT Reading JTaylor BGrimes HMiller f

EMerschoff JStone CAbbate (2)

PMilano j

LParker (2)

BZalcman JPetrosino

)

l l

l l

l

  • See previous page for concurrences.

VPB:00AVT ASC/VPB DQAVT

' B:DQAVT CAbbate:tt*

JStone*

rschoff 03/30/87 03/30/87 4 / s/87