Forwards Evaluation of Chlorine Concentration in Vogtle Electric Generating Plant Control Room, Per SER Open Item 4 Re Toxic Gas Evaluation.Errata Sheet Also Encl
ML20205J691
Person / Time
Site: Vogtle  
Issue date: 02/19/1986
From: Bailey J
GEORGIA POWER CO., SOUTHERN COMPANY SERVICES, INC.
To: Youngblood B
Office of Nuclear Reactor Regulation
Shared Package
ML20205J694 List:
References
GN-808, NUDOCS 8602260341
Download: ML20205J691 (3)


Text

Georgia Power Company Projec2 Myagement Route 2. Box 299A Waynesboro. Georgia 30830 Telephone 404 7244114 404 554-9961 Southem Company Services, Inc.

Post Office Box 2625 Birmingham. Alabama 35202 V.Ogtle Proiect J

Telephone 205 8704011 February 19, 1986 Director of Nuclear Reactor Regulation File: X7BC35 Attentiont Mr. B. J. Youngblood Log:

GN-808 PWR Project Directorate #4 Division of PWR Licensing A U. S. Nuclear Regulatory Commission Washington, D.C.

20555 REF: BAILEY TO DENTON, GN-782, 1/17/36 NRC DOCKET NUMBERS 50-424 AND 50-425 CONSTRUCTION PERMIT NUMBERS CPPR-108 AND CPPR-109

~

V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 SER OPEN ITEM 4: T0XIC GAS EVALUATION

Dear Mr. Denton:

Enclosed for your staff's review is an evaluation of the effects of a postulated onsite chlorine gas release on the habitability of the VEGP control room. This evaluation assumes the chlorine concentration at the Control Building HVAC intake using both.9 and.7 M/sec windspeed. As noted in the referenced submittal the.9 M/sec is representative of the worst fif th percentile wind velocity. Also, please note that an errata sheet has been included in this submittal package.

If yotir staff requires any additional information, please do not hesitate to contact me.

Si cerely,

. f.

J. A. Bailey Project Licensing Manager JAB /sm Enc] caure xc:

R. E. Conway G. Bockhold, Jr.

R. A. Thomas T. Johnson J. E. Joiner, Esquire D. C. ' leper (w/o enclosure) l B. W. Churchill, Esquire L. Fowler (w/o enclosure) l M. A. Miller (2)

W. C. Ramsey B. Jones (w/o enclosure)

L. T. Gucwa Vogtle Project File 0053V B602260341 860219 3

l I

PDS ADOCK 05000424

,' )

PDR j

E t

o.

-1.

4 1

ERRATA The following are corrections which should be included in therreport' entitled ~

" Evaluation of the Chlorine Concentration in the VEGP Control Room".

~

9 The word " zone" should be inserted after the words " control room" in all the following places in the report:

Page Location i

Titles of Sections 2.2,2.4.1, 3.0, and 3.2 2-1 Title of Section 2.2 2-2 Paragraph 1, lines 1 and 4.

Paragraph 2, lines 5 and 7.

2-3 Paragraph 2, line 3 2-4 Last paragraph, last line 2-5 Paragraph 1, lines 2,3,and 5.

Paragraph 2, lines 3 and.13.

2-6 Paragraph 1, line 1 2-8 Title of Section 2.4.1 2-14 Line 2 3-1 Title of Section 3.0 Paragraph 2, lines 1,2, and 5.

Paragraph 3, line 3.

3-7 Title of Section 3.2.

Paragraph 2, lines 1,3, and 12.

Paragraph 1, lines 1 and 2.

3-8 Figure 2 3-14 Line 2 e At the following places "F should be replaced by "f CR CR Page Location 2-9 Table 2, column 6, last line 3-12 Line 7

6:

)..

Errata (cont.)

9 Other corrections Page Location Correction 3-12

_Line 1.

"For t>> isolation time.."

should be. replaced by "For t > isolation time.."

Last line-

~" References 7 through 10" should be replaced by

" References 7 through.9" 3-13 Table 5, column 3, "FCR "sh uld be replaced last line

.by Fout-CR 6-2 Lines 1 and 2 Reference 7 should'be deleted. References 8 through 10 should be numbered 7..through 9.

)