ML20205J660

From kanterella
Jump to navigation Jump to search
Provides List of Number of Tubes Plugged in Each Steam Generator as Result of Recent Insp,Per Tech Spec 4.3.1.B.5.A
ML20205J660
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 09/28/1984
From: Graesser K
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8704010379
Download: ML20205J660 (1)


Text

Y Commonwealth Edison j

Zion G:n: rating Station Shiloh Blvd. & Lake Michigan Zion, Illinois 60099 Telephone 312/746-2084 September 28, 1984 s-h Mr. James G. Keppler, Regional Administrator Office of Inspection and Enforcement Region III IEl U. S.

Nuclear Regulatory Commission CDg6

[

799 Roosevelt Road

-Q DSSS Glen Ellyn, IL 60137 g

w

'j

=HL m

40L

Dear Mr. Keppler,

0E-

=

-d &H /

4 In accordance with Zion Station Technical Specificati W 4.3.1.B.5.A, the number of tubes plugged in each steam generator as a result of the most recent inspection is as follows:

Steam Generator No. of Tubes Plugged (A) 1RC100 None (B) 1RC400 14 (C) 1RC200 25 (D) 1RC300 None If there are any additional questions, please contact Mr.

R.

L.

Sumners of my Technical Staff at Zion Station.

Sincerely,

/

+

m K.

L.

Graesser Superintendent Zion Station KLG/RLS/rmm cc:

E.

Fuerst G.

Plimi K. Kofron A. Miosi W.

Stone F.

Lentine Master File 6

0704010379 040928 Ob PDR ADOCK 0D000295 PDR 1

T 60/

Io

- -