Requests That Documentation of Statements,Discussed in 860724 & 25 Telcons Re 860220 Part 21 Notification Concerning Accuracy of Instrumentation to Detect Inadequate Core Cooling,Be Submitted by 860912
ML20205H063
Person / Time
Issue date: 08/11/1986
From: Rossi C
Office of Nuclear Reactor Regulation
To: Rahe E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
References
NUDOCS 8608190712
Download: ML20205H063 (1)


Text

_.

Mr. E. P. Rahe, Jr.

Manager - Nuclear Safety Department Westinghouse Electric Corporation MjG11 g P. O. Box 355 Pittsburgh, PA. 15230-0355

Dear Mr. Rahe:

SUBJECT:

PART 21 NOTIFICATION DATED FEBRUARY 20, 1986 REGARDING ACCURACY OF INSTRUMENTATION TO DETECT INADEQUATE CORE COOLING Pursuant to July 24 and July)25,1986and Westinghouse (Morris, et al), justification telephone conversations between the NRC staff (Lobel, Karsch, Walker was presented regarding the continued operation of nuclear plants with the Westinghouse Inadequate Core Cooling system installed pending completion of additional qualified life testing of RTD connectors inside containment.

Westinghouse presented information regarding design similarity to connectors which have successfully completed testing and stated that the presently envisioned program is scheduled for completion by November 1986.

In order to facilitate licensing actions currently under review by the NRC staff, documentation of these statements should be provided no later than September 12, 1986.

Sincerely, Oric;inie1 nim 3

Charles E. Rossi, Assistant Director Division of PWR Licensing-A cc:

H. Walker DISTRIBUTION:,

,CentfalJFile!

AD RF

~

RSB RDG CBerlinger RLobel RKarsch PDR TNovak l

l

  • See previous concurrence RSB:PWR-A*

RSB:PWR-A*

RSB:PWR-A*

EICSB:PWR-A*

RKarsch:sl RLobel CBerlinger FRosa Ross 8/7/86 8/7/86 8/7/86 8/7/86 8////86 I

W e)t 8608190712 860811 A

DR TOPRP EMVW i