2NRC-6-088 Be r V 13
- o. 2 Unit Project Organization Telecopy (41 64 Ext.160 P.O. Box 328 August 13, 1986 Shippingport, PA 15077 United States Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Mr. Peter Tam, Project Manager Division of PWR Licensing - A Office of Nuclear Reactor Regulation
SUBJECT:
Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 Use of ASME III Code Case N-318-3
REFERENCES:
(a) DLC letter 2NRC-6-042, dated April 29, 1986, Mr. J. J.
1 Carey to Mr. Peter Tam.
(b) NRC Letter, dated May 27, 1986, Mr. Daniel G. Mcdonald to Mr. J. J. Carey
(,
Gentlemen:
In Reference (a), Duquesne Light Company (DLC) requested NRC approval to use ASME III Code Case N-318-2, " Procedure for Evaluation of the Design of Rectangular Cross Section Attachments on Class 2 or 3 Piping,Section III, Division I," for Beaver Valley Power Station - Unit No. 2 (BVPS-2).
The NRC's response, provided in Reference (b), stated that Revision 2 of the subject code case has been superseded by Revision 3, and that Revision 3 is expected to be included in a future revision of Regulatory Guide 1.84.
DLC was given approval to use Code Case N-318-3 upon submittal of information indicating the intended method of lug attachment, and the piping systems and their locations to which the code case will be applied.
^
' 9
S 1
United States Nuclear Regulatory Commiscion Mr. Peter Tam, Project Manager Use of ASME III Code Case N-318-3 Page 2 The attachment to this letter provides the information requested by the NRC concerning DLC's application of Code Case N-318-3 at BVPS-2. This information is currently being incorporated into the BVPS-2 FSAR (BVPS-2 ASME Code Baseline Document) and the related specifications. Similar in-formation for any future applications of this code case will be provided via revision to the FSAR (BVPS-2 ASME Code Baseline Document).
DUQUESNE LIGHT COMPANY By J. J. Carey Vice President JD0/ijr NR/ASME Attachment cc:
Mr. L. Prividy, Resident Inspector (w/ attachment)
Mr. W. Troskoski, Resident Inspector (w/ attachment) 1
United States Nuclear Regulatory Comission Mr. Peter Tam, Project Manager Use of ASME III Code Case N-318-3 Page 3 COMMONWEALTH OF PENNSYLVANIA )
)
SS:
COUNTY OF BEAVER
)
On this idMday of rM
/fd, before me, a Notary Public in and for said Commhwealth and County, personally appeared J. J. Carey, who being duly sworn, deposed and said that (1) he is Vice President of Duquesne Light, (2) he is duly authorized to execute and file the foregoing Submittal on behalf of said Company, and (3) the statements set forth in the Submittal are true and correct to the best of his knowledge.
' 'killG/ b ~ YW Notary Public swru s. myME.NoicY Pusuc MIPPINSPORT B080. BEAVEE COUNTY
[D". 8ennsyhrania Association of Nater!,s Y C05slSS108 EXPIRES OCT. 23.1939
Application of Code Case N-318-3 at BVPS-2 i
Piping System Location Isometric No.
Line No.
Support No.
Method of Attachment Primary Component Cooling Auxiliary Bldg.
1072001 2CCP-020-461-3 2CCP-PSSP320A Fillet weld 2CCP-PSSP3208 Fillet weld 1072002 2CCP-020-462-3 2CCP-PSSP319A Fillet weld 2CCP-PSSP319B Fillet weld 1072003 2CCP-020-464-3 2CCP-PSSP317A Fillet weld 2CCP-PSSP317B Fillet weld Chemical and Volume Control Cable Vault 1099040 2CHS-003-120-2 2CHS-PSR318 Fillet weld Emergency Diesel Generator Diesel Generator Bldg..1060022 2EDG-038-014-3 2EDG-PSSH028Y Fillet weld 2EDG-PSSP029A Fillet weld 2EDG-PSSP029B Fillet weld 2EDG-PSSH031Y Fillet weld 2EDG-PSSP042A Fillet weld l
2EDG-PSSP0428 Fillet weld l
l b
.