Text

  • l

1 ,

Mr. Tim V. Dr:i:r March 26, 1999

R:gi:nal M: nag:r

Water Management

400 Waterfront Drive

Pittsburgh, PA 15222-4745

Dear Mr. Dreier:

This letter is to address the concerns raised in your letter of March 18,1999, regarding

our inspection findings at the Westinghouse Test Reactor at Waltz Mill, Pennsylvania

(Report No. 50-22/99-201).

Your understanding of the control of radioactive material from the reactor was correct.

Under NRC License No. TR-2 radioactive effluents were being monitored and controlled by

CBS/ Westinghouse in accordance with our regulations. The inspector verified that the

release of any contaminated waste water from the reactor complied with NRC

requirements for release and confirmed that the licensee understood they also had to

ensure that non-radioactive contaminants satisfied the DEP permit requirements prior to

discharge.

Radioactive material at the Waltz Mill Site is controlled under two different NRC licenses.

The reactor itself under License No. TR-2, Docket No. 050-00022, managed by our staff  ;

here at Headquarters and the rest of the site under Licensee No. SNM 770, Docket lio.

070-00698, managed by Region I staff in King of Prussia, PA. Since inspection l

No. 50-22/99-201 concerned only the reactor, contamination outside the reactor itself

l

was not within the scope of the inspection. i

We have contacted Mr. Mark Roberts, the Region I project manager for the remediation of

the rest of the Waltz Mill Site under Licensee No. SNM 770, and have forwarded to him a l

copy of your letter. He is aware of your concerns and should be able to provide you with j

the requested information concerning the characterization and removal of the offsite

contamination.

We thank you for bringing to our attention an error in our inspection report mailing list.

We do show that a copy was sent to Mr. James G. Yusko of your agency. Please notify

us if you wish to have our reports sent to a different addressee. I

Sincerely, o

ORIGINAL SIGNED BY:

Seymour H. Weiss, Director

,

Non-Power Reactors and Decommissioning

9904020049 990326 2 Project Directorate

DR ADOCK 0500 Division of Regulatory Improvement Programs

Office of Nuclear Reactor Regulation

cc: Mark Roberts, RI

DISTRIBUTION:

E-MAIL HARD COPY

AAdams WEresian Central File DMatthews

CBassett Pisaac- PUBLIC SWeiss

TBurdick TDragoun EHylton PDND r/f

PDoyle MMendonca TMichaels OGC (015-B18)

(a'J09

- ,

SHolmes

SHo ep TMich N EN n SWeiss

3 p 3/2(d99 3/2'/99 3/ki99

f

O Al RECORD COPY

no UMENT NAME: G:\SECY\ HOLMES \DRElER N~

.

5 55 WMDM

4 /b'

j. *

{ pa"cg

g i UNITED STATES

! # E NUCLEAR REGULATORY COMMISSION

f WASHINGTON. D.C. 20555-0001

k . . . . . p# March 26, 1999

Mr. Tim V. Dreier

Regional Manager

l Water Management

!

400 Waterfront Drive

L Pittsburgh, PA 15222-4745

Dear Mr. Dreier:

, This letter is to address the concerns raised in your letter of March 18,1999, regarding

! our inspection findings at the Westinghouse Test Reactor at Waltz Mill, Pennsylvania

(Report No. 50-22/99-201).

Your understanding of the control of radioactive material from the reactor was correct.

Urder NRC License No. TR-2 radioactive effluents werrs being monitored and controlled by

'

CBS/ Westinghouse in accordance with our regulations. The inspector verified that the

l_

release of any contaminated waste water from the reactor complied with NRC

l requirements for release and confirmed that the licensee understood they also had to

l ensure that non-radicactive contaminants satisfied the DEP permit requirements prior to

l discharge.

I

Radioactive material at the Waltz Mill Site is controlled under two different NRC licenses.

The reactor itself under License No. TR-2, Docket No. 050-00022, managed by our staff

here at Headquarters and the rest of the site under Licensee No. SNM 770, Docket No.

070-00698, managed by Region i staff in King of Prussia, PA. Since inspection

No. 50-22/99-201 concerned only the reactor, contamination outside the reactor itself

was not within the scope of the inspection.

l

We have contacted Mr. Mark Roberts, the Region I project manager for the remediation of

,

'the rest of the Waltz Mill Site under Licensee No. SNM 770, and have forwarded to him a

'

copy of your letter He is aware of your concerns and should be able to provide you with

the requested information concerning the characterization and removal of the offsite

contamination.

l

! We thank you for bringing to our attention an error in our inspection report mailing list.

We do show that a copy was sent to Mr. James G. Yusko of your agency. Please notify

us if you wish to have our reports sent to a different addressee.

Sincerely,

ey ur H. Weiss, Director

Non-Power Reactors and Decommissioning

Project Directorate

Division of Regulatory improvement Programs

Offic s of Nuclear Reactor Regulation

cc: Mark Roberts, HI