U Entergy Oper:tions,Inc.

Kiliona. LA 70066 Tel 504 739 6242 Early C. Ewing, til f Safety & Regulatory Aftwrs W3F1-99-0056 A4.05 PR March 25,1999 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Personnel Monitoring Reports Gentlemen:

Attached are the fdlowing 1998 Personnel Monitoring Annual Reports submitted pursuant to the requirements of Technical Specification 6.9.1.5:

1. Attachment 1 - Summary of Personnel Monitoring -

End of Year Report 1998

2. Attachment 2 -Work and Job Function Exposure Tabulation -

End of Year Report 1998 /[/

Should you have any questions on the monitoring reports, please contact R.W. Prados at (504) 739-6632.

6o Very truly yours,

\ \ -

! E.C. Ewing Director Nuclear Safety & Regulatory Affairs ECE/RWP/rtk Attachments (w/ Attachments) cc: E.W. Merschoff, C.P. Patel, P. Lewis (INPO Records Center),

J. Smith, N.S. Reynolds, NRC Resident Inspectors Office

~~

9903310287 981231 PDR ADOCK 05000382 R pop

i j

i Attachment 1 to W3F1-99 0056 Sumraary of Personnel Monitoring-End of Year Repod 1998 i

i I

l l

l Waterford 3 SES License: NPF-38 Docket #: 50-382 i i

Summary of Personnel Monitoring - End of Year Report 1998 1

Per Technical Specification G.9.1.5 l I

I I

estimated whole body number of exposure range individuals in f (rems) each range I l

I no measurable exposure .......................... 896 measurable exposure less than 0.1 ........ ...... 190 0.1 to < 0.25 ................................. 77 0.25 to < 0.50 ................................. 13 0.50 to < 0.75 ................................. 1 0.75 to < 1 ................................. 1 1 to < 2 ................................. 0 2 to < 3 ................................. 0 3 to < 4 ................................. 0 4 to < 5 ................................. 0 5 to < 6 ................................. 0 6 to < 7 ................................. 0 7 to < 8 ................................. 0 8 to < 9 ................................. 0 9 to < 10 ................................. 0 10 to < 11 ................................. 0 11 to < 12 ................................. 0 12+ ................................. O Total number of personnel monitored 1178 1

I i

i f

1 i

1 i

{

I J

Attachment 2 to W3F1-99-0056 Work and Job Function Exposure Tabulation -

End of Year Repod 1998 1

i I

4 Wr.terford 3 SES License: NPF-38 Docket #: 50-382 Work and Job Function Exposure Tabulation - End of Year Report 1998 Per Technical Specification 6.9.1.5 Number of Personnel (>100 mrem) Total Man-Rem Station Utility Contract Station Utility Contract WORK & JOB FUNCTION Employees Employees REACTOR OPERATIONS Mnintenance Personnel 0002 0000 0003 2.417 0.000 2.041 Operations Personnel 0014 0000 0000 4.532 0.005 0.266 Haalth Physics Personnel 0011 0000 0001 2.788 0.002 0.212 Supervisory Personnel 0000 0000 0000 0.271 0.000 0.017 Engineering Personnel 0000 0000 0000 0.256 0.004 0.061 ROUTINE MAINTENANCE Maintenance Personnel 0010 0000 0000 3.338 0.000 0.692 Operations Personnel 0003 0000 0000 0.903 0.000 0.038 H;alth Physics Personnel 0000 0000 0000 0.413 0.000 0.025 i

I Supervisory Personnel 0001 0000 0000 0.181 0.000 0.002 Engineering Personnel 0000 0000 0001 0.043 0.000 0.131 INSERVICE INSPECTION Maintenance Personnel 0000 0000 0000 0.010 0.000 0.008 Operations Personnel 0000 0000 0000 0.000 0.000 0.000 Hgalth Physics Personnel 0000 0000 0000 0.000 0.000 0.000 Supervisory Personnel 0000 0000 0000 0.023 0.000 0.000 Engineering Personnel 0000 0000 0000 0.004 0.000 0.000 SPECIAL MAINTENANCE

  • MSintenance Personnel 0003 0000 0000 1.182 0.000 0.290 Operations Personnel 0000 0000 0000 0.064 0.000 0.070 Hialth Physics Personnel 0000 0000 0000 0.199 0.000 0. 98 Supervisory Personnel 0000 0000 0000 0.065 0.000 0.000 Engineering Personnel 0000 0000 0003 0.011 0.000 0.914 WASTE PROCESSING Maintenance Personnel 0000 0000 0000 0.219 0.000 0.040 Operations Personnel 0001 0000 0001 0.226 0.000 0.696 I H;alth Physics Personnel 0001 0000 0000 0.380 0.000 0.047 I Supervisory Personnel 0000 0000 0000 0.019 0.000 0.000 Engineering Personnel 0000 0000 0000 0.075 0.000 0.000 REFUELING l Maintenance Personnel 0000 0000 0000 0.015 0.000 0.000 Operations Personnel 0000 0000 0000 0.001 0.000 0.000 Hcalth Physics Personnel 0000 0000 0000 0.000 0.000 0.000 Supervisory Personnel 0000 0000 0000 0.002 0.000 0.000 Engineering Personnel 0000 0000 0000 0.003 0.000 0.000 TOTALS Maintenance Personnel 0015 0000 0003 7.181 0.000 3.071 Operations Personnel 0018 0000 0001 5.726 0.005 1.070 Hralth Physics Personnel 0012 0000 0001 3.780 0.002 0.482 Supervisory Personnel 0002 0000 0000 0.561 0.000 0.019 Engineering Personnel 000b 0000 0004 0.392 0.004 1.106 i

GRAND TOTAL 0046 0000 0009 17.640 0.011 5.748 1 i

  • For Reactor Coolant Pump Seal Replacement Nota: The dose assignments to the various duty functions are based on electronic dosimeter measurements.  !