86 Enti gy Operttions,Inc.

Killona. LA 7006G Tel 504 739 6242 Early C. Ewing, til tu ar ety & Regulatory Affairs W3F1-99-0042 A4.05 PR 1

March 22,1999 U.S. Nuclear Regulatory Commission j

Attn: Document Control Desk j

Washington, D.C. 20555 i

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 i

Additional Information Regarding inservice Inspection (ISI)

Relief Request ISI-001, Revision 7 Gentlemen:

By Letter W3F1-98-0003, " Inservice inspection (ISI) Relief Request 1S1-001, Revision j

7, Limited Examination of Welds / Components" dated January 27,1998, Entergy provided for NRC Staff review a complete listing of alllim?ed examinations

~

performed during the first inservice inspection interval at Waterford 3, which ended July 1,1997. Whenever a complete examination, as defined by Section XI, is not

//

attainable due to component design or configu*ation, the limitations to the required

'/

examinations must be submitted to the NRC per 10CRF50.55a(g)(5)(iii). In compliance with this regulation, Entergy submitted Re'ief Request 181-001, Revision

7. Per phone conversation with Mr. Chandu Patel of the NRC Staff, further information was requested on four welds. Attachment 1 provides that information.

/t)l[7

~

G

Additional Information Regarding inservice Inspection (ISI)

Relief Request ISI-001, Revision 7 W3F1-99-0042 Page 2 March 22,1999 Should you have any questions or comments concerning this request, please contact me at (504) 739-6242 or Curt Taylor at (504) 739-6725.

Very truly yours,

/~

4 E.C. Ewing

Director, Nuclear Safety & Regulatory Affairs ECE/ CWT /ssf Attachment (w/ Attachment) cc:

E.W. Merschoff, NRC Region IV C.P. Patel, NRC-NRR J. Smith N.S. Reynolds NRC Resident inspectors Office I

Administrator Radiation Protection Division (State of Louisiana)

American Nuclear insurers

Attachmi:nt 1 to W3F1-99-0042 Page 1 of 2 Information on ISI Weld 15-010 This weld is the Pressurizer surge line branch connection weld. The weld received a magnetic particle examination along with a limited ultrasonic examination. The ultrasonic examination was conducted using a 45-degree shear wave. The scans are limited due to the branch connection configuration. The coverage is as follows:

Clockwise circ scan: 100%

Counter clockwise circ scan: 100%

' Upstream axial scan: 0%

Downstream axial scan: 100%

Total coverage: 75%

Information on ISI Weld 19-008 This weld is a stainless steel Safety Iniection pipe to valve weld. The weld received a liquid penetrant examination along with a limited ultrasonic examination. The ultrasonic examination was conducted using a 45-degree shear wave augmented by a 60 degree RL wave. The scans are limited due to the v/ eld material and the valve and weld contours.

The coverage is as follows:

Clockwise circ scan: 100%

Counter clockwise circ scan: 100%

Upstream 45-degree axial scan: 50%

Upstream 60-degree axial scan: 60%

Downstream axial scan: 0%

Total coverage: 65%

information on ISI Weld 25-016 This weld is a stainless steel Combined Pressurizer Spray pipe to valve weld. The weld received a liquid penetrant examination along with a limited ultrasonic examination. The ultrasonic examination was conducted using a 45-degree shear wave augmented by a 60 degree RL wave. The scans are limited due to the weld material and the valve and weld contours. The coverage is as follows:

Clockwise circ scan: 100%

Counter clockwise circ scan: 100%

Upstream axial scan: 0%

i Downstream 45-degree axial scan: 50%

Downstream 60-degree axial scan: 94%

Total coverage: 73.5%

~

Att chment 1 to W3F1-99-0042 Page 2 of 2 Information on ISI Weld 25-018 This weld is a stainicss steel Combined Pressurizer Spray pipe to valve weld. The weld received a liquid penetrant examination along with a limited ultrasonic examination. The ultrasonic examination was conducted using a 45-degree shear wave augmented by a 60 degree RL wave. The scans are limitM due to the weld material and the vr.lve and weld contours. The coverage is as followt Clockwise circ scan: 100%

Counter clockwise circ scan: 100%

Upstream 45-degree axial scan: 50%

Oostream 60-degree axial scan: 65%

Downstream axial scan: 0%

Total coverage: 66%

4 i

1 1

i