Text
_
l BWFC 1086A (8/88)
I THIS MANUAL HAS BEEN ASSIGNEDTO:
O Controlled
%4ncontrolled f
QUALITY ASSURANCE PROGRAM FOR SPENT FUEL & HIGH LEVEL WASTE SERVICES (SFHLWS)
PRODUCT LINE 58' 88 4'
O l
l l
l The holder of this manual is cautioned that the information contained herein must not be loaned or circulated outside the l
Company except as authorized in accordance with B&W Fuel
[
Company Policies and Administrative Procedures. This Manualis the property of the B&W Fuel Company a sd 3 hall be l
returned upon request.
[
l I
I 1
S$d 2$$$5 $$i3S006 C
Lynchburg, Virginia l
h
B&W Fuel Company ps SFHLWS PRO. DUCT LINE QA MANUAL
\\
PAGE OF I SECTION SUBJECT REVISION NO.
NO.
TABLE OF CONTENTS 01 TITLE R EVISION NO.
O.
INTRODUCTION Revision i 1.
ORGANL' ATION Revision 1 2.
QUALITY ASSURANCE PROGRAh!
Revision 1 3.
DESIGN CONTROL Rev!sion 1 4.
PROCUREhtENT DOCUhiENT CONTROL Revision 1 5.
INSTRUCTIONS, PROCEDURES, AND DRAWINGS Revision 1 6.
DOCUhtENT CONTROL Revision 1 7.
CONTROL OF PURCIIASED ITEhtS Revision i AND SERVICES V) 8.
IDENTIFICATION AND CONTROL OF ITEhtS Revision i 9.
CONTROL OF PROCESSES Revision i 10.
INSPECTION Revision !
II.
TEST CONTROL Revision i 12.
CONTROL OF htEASUREh1ENT AND TEST EQUIPh1ENT Revision i 13.
II ANDLING, STORAGE, AND SillPPING Revision i 14.
INSPECTION, TEST AND OPERATING STATUS Revision i 15.
CONTROL OF NONCONFORhtING ITEhtS Revision i 16.
CORRECTIVE ACTION Revision i 17.
QUALITY ASSUR ANCE RECORDS Revision i 18.
AUDITS Revision 1 APPENDIX ADDREVIATIONS AND DEFINITIONS Revision !
l APPROY ED:
,/
DATE: g 36 g/]
hianager, Office of Spent Fuel & liigh Level
'aste Services APPROVED:
j
(( ///ce DATE:
- y. J,.
e r hianager. Quality 8(ssurance NPD
B&W Fuel Company
,o SFHLWS PRODUCT LINE QA MANUAL
/
PAGE OF v
SECT lON SUBJECT REVIS'ON NO NO, INTRODUCTION On O
COhtPLETE REVISION 0.l.
Puroose and Scoce This hianual describes the Quality Assurance Program (QAP) for both the safety and non-safety related products for the Spent Fuel & lilgh Level Waste Services (SFIILWS) Product Line of the B&W Fact Company. The B&W Fuel Company estublishes and maintains standards of quality through the development of operating principles, procedures, and instructions, and the implementation of effective plans. The QAP fulfills the provisions of ANSI /AShtF. NQA l(1986) with supplemental requirements implemented by the procedures referenced in this manual; DOE Office of Civilian Radioactise Waste hianagement (OCRWht)
QA hianagement Policies and Requirements DOE /RW 0032 (10 85); DOE Office of Storage and Transportation Systems (OSTS) QA Directive DOE /Rbl03 (10 86); Appendix B to 10CFR Part 50; 10CFR Part 60; 10CFR Part 71; 10CFR Part 72; and is in accordance with Topical Report BAW 10096A. The procedures referenced and the methods described in this manual have been coordinated with and are mandatory for the applicable organizations.
Each section describes the controls by which the SFIILWS Product Line satisfies the
[m particular area of coverige designated by that section subject title. Procedures which
'v detail how these controls are implemented are listed on the last page of the section.
The SFIILWS Product Line is one of two B&W Fuct Company product !!nes. Each has a separate quality assurance manual.
The B&W Fuct Company is headquartered at facilities of the Babcock & Wilcox Nuclear Power Division (NPD) in Lynchburg, VA., and relies on the NPD to provide certain services and administrative support (see section 1.2, Nuclear Power Division). The NPD Quality Assurance Department provides audit, surveillance and consultation services. This department is also responsibit for maintaining *he AShtE Section 111 QA Pre 3 ram hianual.
Whenever the B&W Fuel Company acts as an A$htE material supplier (to procure and supply material to a fabricator) or as the designer for an "N* stamped Section 111 item, work will be conducted in accordance with the AShtE Section III QA Program hianual maintained by NPD Quality Assurance.
01 Responsibility The General hianager of the B&W Fuel Co. (hereaf ter referred to as the Gen. higr.)
through the hianager, SFilLWS, has the overall responsibility for the quality of work.
Their responsibilities are further defined in section 1.1 of this manual.
The responsibility and authority of the Nuclear Power Division (NPD) hianager of Quality Assurance (QA) are described in section 1.2.1.
(9 The maamgers of supporting and interfacing organizations within NPD are responsible for
(
)
implementing this QA program for work performed within their respective organizations for the SFIILWS Product Line (see sectier.1.0).
~
B&W Fuel Company p
SFHLWS PRODUCT LINE QA MANUAL k
PAGE OF SECTION SUBJECT REVIS$N NO.
NO.
O INTRODUCTION 01 l
0.3.
hisnual Revision Poliev The Gen, higr. through the hianager, SFilLWS is re.<ponsible for the preparation, maintenance, and revision of this manual. The SFilLWS Manager and the NPD hianagar of Quality Assurance shall approve this manual and any revisions thereto. They shall sign and date the Record of Revision page located in front of this manual as evidence of their approval.
This manual and the SFilLWS Product Line Quality Program are reviewed once cach calendar year to determine the need for revision. This review is documented in the manual files maintained by the B&W Fuel Co.
This Manual need not be revised to reflect organizational changes as referenced in the Manual; however, within thirty days of their occurrence, holders of controlled copies of this manual will be notified of significant organizational changes. These changes will be incorporated into this manual during each calendar year review.
k.
When a change is made to this Manual, the revised section(s) and the Table of Contents will be reissued. Changes are identified by a vertical line and revision number in the margin opposite the changed lines. This number will correspond to the revision number in the Table of Contents. Where a section is changed extensively, the words 'COhtPLETE REVISION" may be typed in the upper right corner of the first page of the section in place of the margin lines. This option may also be used for pages that are changed extensively. In this case, the notation will be placed on the changed page. In the event this manual is revised in its entirety, the revision numbe will be shown in the Table of Contents and individual changes need not be identified by vertical lines.
(LL,,btanual Assienments All copies of the QA Manual are issued and plainly identified as either "Controlled
- cr "Uncontrolled," as explained below.
0.4.1 Controlled Manust Controlled copies of B&W Fuel Co QA Manuals are distributed to convenient manual stations located within the AW Fuel Co. This service is performed by NPD for the BAW F uel Co. In accordance with the service agreement described in section 1.2. NPD has a similar manual station plan for its organization. The Manager of SFilLWS of the B&W Fuel Co. distributes controlled copies to selected B&W employees and to organizations outside of the B&W Fuel Co, Individual manual holders are listed on a controlled distribution list. The SFilLWS manager is responsible for keeping the list up to-date and
/,}
for sending the manuals to all persons on the distribution list.
t
B&W Fuel Company SFHLWS PRO, DUCT LINE QA MANUAL
(
PAGE OF SECTION SUBJECT REVISION NO.
NO.
O INTRODUCTION 01 0.4.2 Uncontrolled Martu21 Uncontrolled manuals are issued for information only. Msnual release; may be sent to the holder, but no assurance is required that the manual is kept up to date.
0.5.
Manual Structure This manual defines Quality Assurance Program (QAP) requirements and is structured to provide a ready reference to information pertaining to the various elements of the QAP.
Specific administrative procedures and instructions that support the program are referenced (by number and title) at the end of each section. These procedures and instructions are not a part of the QA Manual but are kept at the manual stations.
O J
- 1. 2
B&W Fuel Company n
SFHLWS PRODUCT UNE QA MANUAL PAGE OF SECTION SUSJECT REYiSION NO.
NO.
I ORGANIZATICN g
COhtPLETE REVISION
- 10. GENERAL The SFilLWS Product Line is cne of two product lines within the B&W Fuel Company. It is supported by resources both within the B&W Fuel Company and the Nuclear Power Division. These resources are described in the following paragraphs.
1.1. B&W Fuel Company The B&W Fuel Company (see Figure 1) is a separate partnership where Babcock & Wilcox owns a 51% majority interest. A French consortium, composed of Cogema, Inc., Framstome and Uranium Pechincy, has a minority interest of 49%. The B&W Fuel Company is an organizational part of the Nuclear Power D7 vision of Babcock & Wilcox and has access to its resources.
The B&W Fuel Company is headquartered in ths 4uclear l'ower Divistori offices in Lynchburg, Virginia. The General hianager of the B&W Fuct Company reports to a n
[ ))
Partnership Board consisting of the NPD Vice President and General hianager (representing
(
B&W's majority interest) and a representative of the French consortium.
The General Stanager of the B&W Fuel Company is responsible for the quality assurance, marketing, project management, business development, enginecting, and manufacturing for the B&W Fuel Company Product Lines.
The General bianager executes his various responsibilities through his staff and through the hianager of SFIILWS for the SFiiLWS Product Line. The B&W Fuel Company organizations involved in the SFliLWS activities are SFiiLWS, SFilLWS Quality Assurance, Fuel Engineering, and Fuel and Specialty hianufacturing.
1.1.1. Scent Fuel & liinh LeuL%_'aly Services (SFilL%lSJ The hianager of SFilLWS reports to the General blanager of the B&W Fuct Company. The General blanager has delegated to him the responsibility for the quality assurance, marketing, project management, business development, engineering, and manufacturing < f products and services related to the handling and disposal of spent fuel and high level wastes. The Quality Assurance program activities are discharged through the SFilLWS Product Line QA representative.
LL:L SFilLWS Ouslity Assurance The SFilLWS QA.epresentative reports to the hianager of SFilLWS and has a reporting relationship to the hfanager of NPD Quality Assurance on quality matters. lie is
- h independent of cost and schedule issues and has direct access to all levels of the B&W Fuel Company and NPD m4nagement and has the authority and organizational freedom to:
(a)
Provide SFiiLWS Product Line QA services
B&W Fuel Company n
SFHLWS PRODUCT LINE QA MANUAL f
PAGZ OF SECTION SUBJECT REMSlON NO.
NO.
I ORGANIZATION 01 (b)
Assure that the SFIILWS Product Line QA Program meets all applicable requirements.
(c)
Conduct overchecks, audits and surveillance visits to confirm that the requirements of the SFIILWS Product Line QA program are being met.
(d)
Initiate, recommend, or provide solutions to quality problems and verify impleme itation of solutions.
(c)
Prepare and maintain the SFilLWS Product Line QA Program to include updating this manual.
(f)
Assure that the QA Program includes both the performing functions of attaining quality objectives and the quality assuratice functions of assuring and verifying that activities affecting quality are correctly performed.
(g)
Implement with written instructions or procedures, those portions of the QA Program (O
for product line work performed within the B&W Fuel Company and by oth:r V) organizations.
(h)
Provide the product linc's control over activities affecting the quality of its products.
(i)
Provide for indoctrination and training of personnel performing activities affecting quality.
(j)
Cause quality problems to be evaluated as to determine the underlying causes of the problems and to recommend corrective actions to prevent recurrence.
(k) Suspend or control further processing or delivery of a nonconforming item until proper disposition of the deficiency or unsatisfactory condition has been approved and documented.
(1)
Sign as approver of all Certificates of Compliance.
(m) Review and approve QA content of every Procurement Authorization get; crated by SFIILWS.
1.1 1 Fuel Eneineerine The Manager of Fuct Engineering reports to the General Manager of the B&W Fuel Company and is responsible for (as may be assigned):
(a)
Design of SFIILWS related products.
(b)
Preparation of manufacturing specifications and drawings.
(c)
Advanced technology in the areas of thermodynamics, physics, applied mechanics, thermal hydraulics, and mechanical design.
~
B&W Fuel Comparty lq SFHLWS PRO, DUCT LINE QA MANUAL k_j PAGE OF SECTION SUBJECT REYlSION NO.
NO.
1 OP.GANIZATION 01 1.1.4. Fuel and Soeelalty hisnufacturin The Stanager of Fuel and Specialty hianufacturing reports to the General blanager of the B&W Fuel Company, lie is responsibla for the Commercial Nuclear Fuel Plant (CNFP).
Principal activities of the CNFP include fuel rod loading and fabrication, fuel assembly operations, spacer grid fabrication, canister and cask fabrication, and the machining of miscellaneous small components and specialty manufacturing items. The CNl:P is considered to bs a suppli:r and quailty assurance requirements are invoked through the procurement package (ref er to section 4.0),
1.2.
Nucient Power Division (NPD)
The NPD is a major supplier of commercial nuclear equipinent and services. Within NPD, the business units and departments other than the B&W Fuel Company that are involved in the SFilLWS Product Line are: Nuclear Operations and Administration Nuclear Engineering and Plant Services, und Specialty Products and Integrated Field Services (reier to Figure O
2 ).
\\V)
L 2.1. Nuclear _Qoerations and Administration (NO& A)
The hianager of NO& A reports to the Vice President and General hianager of NPD. The activities within NOA A that support the SFilLWS product line f.re: NPD Quality Arsurance, Technical Services, Employee Relations, and Purchasing.
1.2.1.1. NPD Ouality Assurance The hiana::er of NPD Quality Assurance reports to the hianager of NOAA and maintains a reporting relationthip to the Vice President and General blanager of NPD in quality related matters. Ile is responsible for providing quality assurance management for all NPD activities.lle provides consultation, advice, and services to the B&W Fuel Compsny as described in section 2.2. In addition, he nrovides record management and administrative procedure services to the B&W Fuel Company.
Record hianagement provides for identification of B&W Fuel Company /NPD and suppl lcr prepared technical documents; initial interr.al distribution of D&W /uct Company /NPD technical documents; operat!on of a storage, retention, and retrieval system for records vital to B&W Fuel Company /NPD that meets the requirements of ASNtE/ ANSI N45.2.9 1974 and NQA l.1986; and maintenance of a documentation data base which is used to produce a listing of approved safety related QA records for contracts released after June 10, 1975.
Administrative Procedure Services coordinates, processes, and distributes internally within B&V Fuel Cosapany/NPD QA Program hianuals, Administrative Procedures, Operating p}
Principles, and Operating Instructions.
I m
B&W Fuel Company o
SFHLWS PRO, DUCT LINE QA MANUAL PAGE OF SECTION SUBJECT REVISICN NO.
NC.
I ORGANIZATION 01 1
1.2.1.2 Emolovee Relatiern The hianager of Employee Relations reports to the hianager of NO&A. lie maintains a file of Position Dc:eriptions that describe the responsibilities, autnority, and reporting relationships of individuals in B&W Fuel Company /!!PD. lie also assists B&W Fact Company /NPD in planning, evaluating, ccordinating, arid record keeping for training of B&W Fuel Company /NPD personnel.
L2.1.3. Technical Servlees The hianager of Technical Services reports to the hianager of NOAA. lie is respon?ible for engineering application programming and graphic design. Engineering application programming programs software la accordance with engineering instructions and graphics design provides drawings as specified by engiacering organizations 13.1.4 Purchssina f
The hianager of Purchasing reports to the Manager of NO&A. lie is responsible for
(#
procurement of items and services from non B&W suppliers.
1.2.2. Nuclest Eneineer!nv and Ptsnt Servis.es (NEP.51 The hiinager of NEPS reports to the Vice President and General blanager of NPD. lie is responsible for the management of engineering and field services for nuclear power plants.
1.2.3. Specist Products and Inteersted Field Services (SPIS)
The hianager of SPIS reports to the Vice President and General hianager of NPD lie is responalble for the management of engineering and field services for special products, steam generators, and non destructive examinations, 1.3. OrilER B&W ORG ANIZ ATIONS The SFilLWS Product Line has access to other B&W divisions where their specialized knowledge and expe'tise will contribute to the quality and completeness of the product or service. These B&W d:<isions, such as the Research & Developmcat Division (R&DD) and Nuclear Equipment Division (NED), are considered to be suppliers and quality assurance requirements are invoked through the procurements package (refer to section 4.0).
= _ _.
B&W Fuel Compar:3' SFHLWS PRODUCT LINE QA MANUAL s
7 PAGE OF SECTION SUBJECT REVISION Figure 1. D&W Fuel Company Organizations involved in SFIILWS Q/. Program 01 Partnership Board VP & GM - NPD and French Representative O'
General Manager i
i Manager Manager Manager Fuel Engineering Spent Fuel and High Fuel and Specialty Level Waste Services Manuf acturing f
Commercial SFHLWS Q A Nuclear O
Reore s enta tiv e Fuel Plant
B&W Fuel Comp.any (V)
SFHLWS PRODUCT LINE QA MANUAL 6
7 i
PAGE OF i
SUBJECT REYlSION SECTION NC.
NO.
Figure 2. Nuclear Power Division Organizations involved in SFIILWS QA Program Of Vice President &
General Manager Manager Manager Manager Nuclear Engineering Nuclear Operations Special Products and Plant Services and Adminstration and integrated Field Services 7..............................
O l
Manager Manager Manager Manager
[
~
Employee Quality Technical Purchasing Assurance Services Relations i
Manager I
Manager Manager SFHLWS Purchasing QA Records Q A Audits &
and QC Representative Management Progre.ms Sur v eillanc e i
\\
Adminis t r a tiv e Procedure l
Services
B&W Fuel Company
/3 SFHLWS PRO, DUCT LINE QA MANUAL k)
PAGE OF SECTION SUBJECT REVISION NO.
NO.
1 ORGANIZATION 01 R
1 Reference Procedures NPC 121212 Procurement Document NPG 1303 07 Preparing and Processing Administrative Procedures NPG 130317 Operating Instructions NPG 1702 26 NPD QA Program NPG 1708 08
- QC Surveillance NPG 170416
- QA Review of Procurement Documents NPG 1719 22
- QA Audits of NPD Suppliers NPG 1719 21
- QA Audits of NPD Activities NPG 130315 Control of Manuals i
i 01 1262
- Qualifict. tion & Certificas n of QCS Representatives 01 1280
- Qualirication of QA Audit Personnel IEl Revords Management Program l
09 1212
- Quality Assurance Program Requirements for Nuclear Equipment l
09 1427
- Quality Assurance Requirements for Research and I
Development
{
J i
l F
_ - - - _, ~,, _, _-,.--.- _
-.m-- - - -
B&W Fuel Company n
SFHLWS PRO, DUCT LINE QA MANUAL PAGE
' OF 0
SECTION SUBJECT REYlSION NO.
NO.
2 QUALITY ASSURANCE PROGRAh!
01 COhtPLETE REVISION 2.1. General The overall objective of the SFilL%T Product Line Quality Assurance Program is to ensure the safe, reliable performance of its products and services.
The QAP takes into account the prerequisites for achieving quality, such as the need for specialized equipment and skills, suitable administrative and process controls, indoctrination and training of personnel performing activities that affect quality, and the need for verification of quality by inspection and tests.
Individual managers provide training for personnel under their direction to the extent necessary for the employee to achieve and maintain a level of proficiency satisfactory to the manager. To achieve employee training consistency throughout the B&W Fuel Co.,it is mandatory that managers, follow as a minimum, the guidelines established by procedures.
Tralping programs are provided for QA personnel to develop and maintain expertise in QA m
and QC philosophy and n..: nods and to maintain qualified individuals for surveillance and V) auditing.
1 2.2. Quality Assursnee Oresnirstion The DAW Fuel Co. is responsible for the overall progran. In discharging this responsibility, the D&W Fuel Co. uses a QA Representative for the SFilLWS Product Line (see section 1.1.2) and services from NPD Quality Assurance (see section 1.2.1.1).
The B&W Fuct Co. has contracted with the hianager of NPD QA for the following:
o Review and approval of B&W Fuci Co. CA programs and implementing Administrative Procedures and instructions.
o hiaintenance of QA Topical Report BAW 10096A and AShtE Section III QA Program.
O Coordination of the interface with the NRC & AShtE for Audits and other QA matters, o
Initiation of the annual hianagement review of the implementation of QA Topical Report 10096A and coordination of the responses to these roanagement reviews, o
Assistance in customer QA audits where D&W Fuct Co. product lines are involved o+
upon request, o
Performance of internal audits of B&W Fuel Co. Quality Assurance Representative activities and other QA activities as appropriate.
(()
o Furthermore, the B&W Fuel Co. requires NPD QA to:
B&W Fuel Company o
SFHLWS PRO, DUCT LINE QA MANUAL 2
0 PAGE 0F SECTION SUBJECT RCYlSION NO.
NO.
2 QUALITY ASSURANCE PROGRAM 01 Evaluate and approve suppliers, conduct supplier audits, maintain the approved supplier list, maintain the QA specifications for supplier QA programs, approve supplier NDE procedures (Note: Does not include CNFP suppliers).
Train, qualify, and certify QA audit and surveillance personnel (Note: Does not include CNFP persorsci) and maintain personnel qualification records.
Provide advice and consultation on QA matters.
Review procurement documents for ASME Section til items.
In discharging the requirements of the Quality / hurance service contract between the B&W Fuel Co. and NPD QA, NPD QA shall have the responsibility, authority and organizational freedom to:
A o
Identify quality problems; initiate, recommend, or provide solutions; verify (U) implementation of solutions; and limit or control further processing, delivery, or installation of nonconforming itemt or unsatisfactory conditions until proper disposition has occurred.
o llave direct access to all levels of D&W Fuel Co. management including physical access to all facilities.
o Perform designated QA services.
o llave the right of approval of QA programs and implementing Admialstrative Procedures and instructions to ensure compliance with requirements such as 10CFR50 Appendix D, BAW 10096A, ASME/ ANSI NQA 1,10CRF60,10CFR71,10CFR72, DOE Standards, Customer Requirements, etc.
o liase the right to perform overcheck audits or surveillance of B&W Fuel Co. activities to assure that personnel are effectively discharging their assigned dutica and l
responsibilities.
- 13. Ouslity Asstrance Audits The QA Representative for SFilLWS Product Line directs a program of pre award and periodic supplier audits. These are performed by NPD QA. The QA Representative aho conducts periodic audits of D&W Fuel Co. internal operations to overcheck, measure and verify conformance to the requirements of this QA Program. Pre award audits evaluate the m
QA program of prospective suppliers. Periodic internal and supplier audits measure implementation and evaluate complialce. Each of these audits includes a check to confirm v
the existence of suitable programs to verify the quality of the product. Any discrepancies found during the process of audits are controlled by issuing formal audit reports.
B&W Fuel Company
(]
SFHLWS PRODUCT LINE QA MANUAL 6
j PAGE OF SECTION SUBJECT REVISION NO.
NO.
2 QUALITY ASSURANCE PROGRAM 01 2.4. Procurement and Ouality Control Surveillanet All surveillance personnel are properly qualified and trained for the specific task in accordance with the requirements of ANSI /ASME N45.2.6. and ANSI /ASME NQA l.
In a.m and final surveillance as required by the procurement documents are performed at the supplier's plant. The QA Representative,in his review of safety related procurement documents shall ensure that in process and final surveillance activities are performed when necessary. Surveillance reports are prepared for each surveillance indicating results and are submitted to the QA Representative.
On encountering nonconforming materials and items, the person performing surveillance identifies non conformances to the supplier and prepares a non conformance report. The QA Representative shall follow non conformances to satisfactory resolution and ensure that unacceptable nonconforming materials and ite.ns are not used.
O)
(V On receipt and approval of all required supplier documentation. SFilLWS Product Line QA personnel teview and approve a QA data package for transmittal to the customer. The QA data package, a selected part of the total QA records for each contract, is compiled from supplier furnished documents in compliance with QA requirements imposed on the specific contract. The requirements of the customer purchase order as interpreted by the B&W Fuel Co. define the documents to be furnished by the suppliers for inclusion in the QA data package.
The SFIILWS QA representative review procurement packages and procurement authorizations for inclusion of appropriate QA requirements.
2.5. Ouality Classification The SFilLWS Product Line classifies items or services as either safety or non safety related. The criteria for classification corresponds to DOE Documents DOE /RW 0032 (10 85) and DOF/RW 0103 (10 86) as follows:
Safety related (DOE Quality Levels I & 2):
Items or services that have significant potential impact on public radiological health and safety;and/or potential impact on public and/or occupational radiological health as required by 10CFR20, public and occupational safety, and/or the attainment of other major programmatic objectives (e.g. cost benefit optimization, schedule maintenance.cnvironmental protection, etc.) are classified as safety related and are controlled under the provisions of this manual.
A
\\m
B&W Fuel Company
' n SFHLWS PRODUCT UNE QA MANUAL 0
PAGE OF SECTION SUBJECT REVISION NO.
NO.
2 QUALITY ASSURANCE PROGRAM 01 Non Safety related (DOE Quality Level 3):
Items or services tl.at have minor or no potential impact on the factors identified above the safety rel'ted classification are classified as non safety related and are, as a minimum, controlle(. ;. asurance measures in accordance with good management, enginet. ring, or lce s.
laborator!
The safety,Non safety related classification of in item or service is included in the design and procurement documents discussed in sections 3 and t of this mar.ual.
2.5. Contract Soecific OA Programs Customer contracts sometimes require changes in the QA program, quality classification of components and added quality contrels (e.g. software QA programs). When required, these changes are approved by the Project Manager and the SFHLWS QA Representative. In the event a separate manual or procedure is necessary,it will be reviewed and approved in p) accordance with the B&W Fuel Co. procedures governing the preparation, approval and
(\\d issuance of quality assurance manuals.
2.7. Site Services The B&W Fuel Co. under contract with our customers, performs site services such as site examinations of components and assemblies, training services, installation services and repair services. The contract stipulates the technical, quality assurance requirements, and the terms and conditiens for this work. Normally these services are performed in accordance with the customer's site quality assurance program. In the event the customer requests a contract specific QA program, such a program will be developed and initiated in acco; dance with established procedares governing the preparation, approval and issuance of quality assurance manuals.
2 8. Quality Assu_rance Management Information The Division QA Manager, the SFHLWS QA representative and other involved Business Unit / Product Line Managers provide the following information, as appropriate, to the B&W Fuel Company Ger.crat Mansger and/or NPD Vice President and other involved managers through their Monthly Activities Reports:
(a)
Status of development of QA plans and procedures.
(b) Significant quality ptoblems and unusual occurrences and their resolution statut.
(c)
QA management practices and improvements, v
(d) Quality verification results, including significant findings and their resolution.
(c)
Quality performance trend analysis results.
B&W Fuel Company (N
SFHLWS PRO. DUCT LINE QA MANUAL O
0 PAGE OF ISECTION SUBJECT REVISION NO.
NO.
2 QUALITY ASSIJRANCE PROGRAhi 01 (f)
Status of holds.
QA management information, including the interpretation of QA requirements, exemplary and innovative QA practices, and lessons to be learned from significant quality problems and unusual occurrences are, as approp-late, disseminated by the Division QA hianager, and/or SFilLWS QA Repreacntative to all affected organizations.
The hianager of Spent Fuel and fligh Level Waste Services provides the following information, based upon input from the Division QA hianager, and/or SFilLWS QA Representative, and other involved mar. agers, to the customer.
(a)
Controlled copy of this QA hianual when requested. Referenced procedures are availh:s for review at B&W/ Fuel Company offices.
(b) Copies of QA audit schedules, audit reports, and related correspondence are available for review at B&W/ Fuel Company offices.
(c)
Copics of summary reports on significant quality problems, unusual occurrences, issues, and their resolution or corrective action status.
(d) Quarterly reports on the
"'us, adequacy, and effectiveness of the QA program are available for review at ?'
..el Company offices, bO L,
B&W Fuel Company SFHLWS PRO. DUCT LINE QA MANUAL 6
0 PAGE 0F 1 SECTION SUBJECT REVISION NO.
NO.
2 OUALITY ASSURANCE PROGRAh!
01 2.9. Reference Procedures 09 1212
- Quality assurance Program Requirement Specification for Nuclear Equipment NPG 130315 Control of hianuals NPG 1702 26 NPD QA Program NPG 1702 22 Employee Training NPG 1702 25 Assignment of Nuclear Safety Classification to Products and Services NPG 1705 03
- Quality Assurance Data Package and NPD Certificates of q
Conformance NPG 170516
- QA Review of NPD Procurement Packages NPG 1708 08
- Quality Control Surveillance NPG 1719 21
- QA Audits of NPD activities NPG 1719 22
- QA Audits of Suppliers r
NPG 1702 27
- Quality improvement Practices i
1 1
B&W Fuel Company G
SFHLWS PRODUCT LINE QA MANUAL
'n-PAGE OF GCTION SUBJECT REh0N NO.
NO.
~
3 DESIGN CONTROL 01
- 31. General SFiiLWS is responsible for the mechanical, nuclear, and thermal hydraulic design, development, design serification testing, and manufacturlag of hardware for waste disposal and handling spent fuel, and related products and services. The division of responsibility for design activities and the methods and procedures used to control specification review, approval, and transmittal of design information are documented in NPD procedures as references on page R 1 of this section. These procedures and changes to these procedures are rev'cwed and approved by the B&W Fuel Co. and NPD Quality Assurance.
The administrative procedures that govern the design activities ensurc quality is considered in every design activity. They ensure that the design is carried out in a planned, controlled sad correct manner hicasures are provided for design document control, independent verification, appropriate reviews and app ovals, design verification testing and auditing with appropriate corrective action to assure that the design program is functioning as planned. These procedures also include means to ensure the selection of suitable
/7 materials, control of design interfaces, release of appropriate design specifications and the
(
evaluation of design changes.
'm
- 12. Desian Bases The design criteria, applicable regulatory requirements, and configuration for SFilLWS-supplied components are described in tFe applicable design bases documents. Interface design requirements, design base documents, site specific design requirements, and contract requirements are prepared and maintained by individual Project hianagers.
D Desien Process Detail design documents are prepared by cognizant engineers from the design bases. The flow of design information is controlled by appropriate transmittal sheets. Design documents are independently reviewed by qualified personnel.
3.4.
Desien Verifiestion The adequacy of SFl!LWS products to satisfy design bases and regulatory requirements is evaluated by one or more of the following verification methods, o
Formal design reviews are conducted in accordance with procedures as part of the design process.
o Design calculations are verified by independent review.
o Development or prototype tests are performed.
B&W Fuel Company e
SFHLWS PRO, DUCT LINE QA MANUAL 2
(f PAGE 0F SECTION SUBJECT REVISION NO.
NO.
3 DESIGN CONTROL 01 3 5. Confinurstion Control Detail manufacturing requirements are defined by the Applicable Document List. This list includes drawings, material and process specifications, appropriate quality standards, and special instructions. These documents are reviewed and approved by Fuct Engineering and/or supporting engineering organizations.
3.6. Channe Control Changes to design documents and other technical requirements documents are authorized utilizing a change approval and control system described in the referenced procedures.
These approvals are commensurate with the original approval process of the document being changed.
3.7.
Deslan Review Board p
Independent design review boards are convened as needed to evaluate new product designs or services or major changes to existing products or services. The board is responsible for Ik verifying the adequacy of the design or service and to ensure that applicable requirements have been considered in the product design.
1 0
B&W Fuel Company SFHLWS PRO. DUCT LINE QA mal,UAL m
3 PAGE OF SECTION SUBJECT REVISION NO.
NO.
3 DESIGN CONTROL 01 3.8. Reference Procedures and Document NPG 0402 01 Preparing and Processing NPD Calculations.
NPG 0403 il Techt Mal Document Signatures.
NPG 0405 21 Change Authorization (CA).
NPG 0405 22 Design Review Board.
NPG 0405 30 Design Verification Testing.
NPG 0408 08 Materials Review and Consultation.
NPG-0412 55 Design Specifications / Requirements Documents.
NPG 0412 57 Prep 1 ring NPD Detail Design Documents.
NPG 0412 58 Processing NPD Prepared Detail Design Documents.
NPG 0412 59 Engineering Information Record / Technical Data Record.
t NPG 0412 67 Processing Technical Documents from Suppliers and Customers.
NPG 041412 Preparation of Licensing Documents.
NPG 041413 Processing Licensing Documents.
1 NPG 0503 07 Field Change Authorization (I-CA).
NPG 0902 06 Computer Program Development and Certification.
NPG 0902 07
- Development, Verification and Release of Standard Mathematical Sof tware.
Development of Certified Computer Program User NPG 0903 03 Ma n uals.
B&W Fuel Company n
SFHLWS PRODUCT LINE QA MANUAL A
PAGE 0F SECTION SUBJECT REVISION NO.
NO.
4 PROCUREMENT DOCUMENT CONTROL 01 4a.
General Project Managers are responsible for procuring product line components and services. Some components are procured from the CNFP or NED while other items may be purchased through N."D Purchasing. In all cases a Procurement Authorization (PA) is used. Services, such as consultant services, can be procured through the CNFP or NPD Purchasing using a PA.
The R&D Division, other Company Divisions and outside suppliers offer the SFilLWS Product Line an increased scope of materials and services. These materials and services include prototype testing, consulting services, site services, and special systems and hardware. All are procured in accordance with NPD procedures.
41 Procurement Packaee The procurement package contains the transactional document the Procurement n
Authorization (PA) and the technical and QA requirements. The PA is a controlled
(,-)
(
document that is changed and re approved in the same manner as it was originally approved.
Technical and QA requirements are prepared and reviewed by the organizational positions responsible for the preparation and review of all technical documents. The SFitLWS Product Line QA representative reviews all safety related procurement packages for his 01 approval.
4.3.
Quality Assurance Proaram Reauirement Soecification QA requirements are invoked on items or services by procurement documents. QA Specification 09 1212 is a D&W standard document that addresses the 18 criteria of l01 10CFR50, Appendia D, and requires the suppliers of safety related items or services to organize, plan, establish, implement, and maintain systems using written procedures to control product qual?ty. This specification includes all elements of the manufacturing process and the administrative functions necessary to ensure that the items conform to the NPD requirements. Non safety related materials and services are procured to the requirements of the procurement document. In some instances the QA Specification 09 1212, although not specifically required,is invoked on non safety related items.
The procurement package identifies the paragraphs of the QA specification applicable to the line item for procurement of SFilLWS products and other materials and services. Suppliers, including the CNFP, are responsible for the QA requirements necessary to meet the quality requirements, either through imposition on vendors, or by fulfilling the requirements directly.
I(v)
B&W Fuel Company SFHLWS PRO, DUCT LINE QA MANUAL O
PAGE OF i
SECTION SUBJECT REVISION NO.
NO.
4 PROCUREMENT DOCUMENT CONTROL 01 1 Reference Procedures 09 1212 Quality Assurance Program Requirements Specification for Nuclear Equipment, NPG 0412 66 Release of Product Documentation.
NPG 121212 Procurement Documents.
l O
l l
l l
B&W Fuel Company m
SFHLWS PRO, DUCT LINE QA MANUAL PAGE OF SECTION SUBJECT REVISION NO.
NO.
5 INSTRUCTIONS, PROCEDURES, AND DRAWINGS 01 5.1.
General Activities % =ecting quality are prescribed by documented instructions, procedures, or drawings of a type appropriate to the circumstances. These.locuments include appropriate quantitative or qualisative criteria for determining whether an activity has been satisfactorily accomplished.
5.2. Imolementation The provisions of the Quality Assurance Program are implemented by written operating principles, procedures and instructions. Detailed procedures governing the activities of all B&W Fuct Co. organizations are based on operating principles issued by NPD QA. These procedures are prepared, reviewed and approved by the affected organirstions and then approved by NPD Quality Assurance arid the SFilLWS QA Representative. Such procedures may be supplemented by Operating Instructions (OI) which are developed by the user 01 organizations and, insofar as they affect quality, are reviewed and approved by NPD QA m
and the QA Representative.
The QA Representative performs audits to verify that activities affecting quality are performed in accordance with approved and appropriate instructions, procedures and drawings and that documentation exists to verify this fact.
1 l
l B&W Fuel Company SFHLWS PR0pVCT LINE QA MANUAL Q
PAGE
' 0F SECTION SUBJECT REYlSION NO.
NO.
5 INSTRUCTIONS, PROCEDURES, AND DRAWINGS 01 5.3 Reference Procedures Design Specifications / Requirements Documents.
NPG 0412 55 Preparing NPD Detail Design Documents.
NPG 0412 57 NPG 0412 58 Processing NPD Detail Desiga Documents.
I NPG 0412 59 Engineering Information P.ecord/ Technical Data Record.
NPG 0412 63 NPD Technical Document Format.
NPG 0412 67 Processing Technical Documents from Suppliers and Customers.
NPG 1303 07 Preparing and Processing Administrative Procedures.
NPG 130315 Control of Manuals.
Operating Instructions.
NPG 130317 NPG 1305 01
- Forms Control, t
I l
B&W Fuel Company r3 SFHLWS PRO. DUCT UNE QA MANUAL PAGE OF SECTION SUBJECT REVISION NO.
NO.
6 DOCUhtENT CONTROL 01 COhtPLETE REVISION 6.1.
General Operating principles, procedures, and instructions are maintained to provide guidance to personnel thereby ensuring the uniform application of standard practices throughout the B&W Fuel Co. Design and technical documents (including changes) are reviewed for adequacy, approved for release by authorized personnel, and distributed to and used at the location where the prescribed activity is performed.
NPD Records hianagement has the responsibility for document control; i.e., logging, assigning document identificaticn numbers, and distribution of the documents generated by the B&W Fuct Co. and suppliers.
61 Oustity Assurance hianud Preparation, revision, and distribution of this Quality Assurance blanual is described in the Introduction to this hianual.
/
\\)
al Ooerstine Princioles Operating Principles pertain to matters that affect the B&W Fuel Co. and the Nuclear Power Division as a whole and reflect the continuing decisions of the Division Vice President and General blanager.
6A Administrative Procedures and hianusts l
Administrative procedures are written statements used to describe methods of performing B&W Fuel Co. operations and to implement the administrative policies consistently across the NPD and the B&W Fuel Co. They assign responsibilities and describe the interactions performed by and between organizations in order to acco.nplish specific objectives. The procedures may also delineate documentation requirements, flow, and retention.
Administrative procedures arc prepared by the organizations responsibt: for the described function. The procedures are coordinated with the NPD and the B&W Fuel Co.
organizations. NPD QA assures agreement between procedures and is responsible for procedure release. Procedures or ch,5nges to the procedures must be approved by the B&W Fuct Co., SFilLWS QA Representative and by each affected NPD business unit or department before release. Released procedures are filed at NPD and B&W Fuel Co. manual stations and distrib4ted to others by NPD QA.
6 5.
Ooerstine Instructions x
Operating instructions describe how to perform functions or responsibilities imposed by
}
published higher tier administrative documentation and can not change in any way the C/'
scope of thr functions or responsibilities imposed. Operating instructions must be approved by the B&W Fuel Co. General hianager and by NPD and B&W Fuel Co. Quality Assurance.
The released operating instructions are filed at the appropriate NPD manual stations by
B&W Fuel Company
(
')
SFHLWS PRODUCT LINE QA MANUAL 2
3
~#
PAGE 0F SUBJECT REVISION SECTION NO.
NO.
DOCUMENT CONTROL 01 6
1 6.6.
Desian Documentation Control Design documentation control is the responsibility of the B&W Fuel Co., and support engineering organizations, The design control system (as described in section 3) ensures that contract and design requirements are correctly translated into specifications, drawings, procedures, and instructions. Any obsolete documents including drawings, specifications and instructions are isolated from use or destroyed.
A document list, referred to as an Illstorical Document List (IIDL)is maintained to provide identification status and the relationship of safety related design documents.
The release of design documentation for use on a particular contract is controlled by a document release notice (DRN), Applicable Document List ( ADL), or Document Comment Form (DCF). The DRN is caed to release NPD or B&W Fuel Company prepared product documents within the Division oi B&W Fuel Company. It is prepared by the originator of the document.
\\
6.7.
Detsil Deslan Document Control Detail d'esign documents are prepared by SFilLWS or its support engineering organizations to satisfy design requirements of an item and consist of documents such as fabrication drawings and specifications. Responsibility for preparing detail design documents is assigned to the cognizant engineer. They are reviewed by an independent engineer and approved by the engineer's manager.
SFilLWS Product Line documents are released to purchasing or other B&W organizations by Procurement Authorization (PA). The PA, the Applicable Document List (ADL) and the drawings and specification form the procurement package. Records Management distributes copics of the procurement package according to the PA distribution list. Orders placed with suppliers external to B&W are initiated by purchase orders (PO). Changes are transmitted by PA to Purchasing via the procurement package. The supplier acknowledges receipt by signing the PA or PO.
6.8. Suceller Preosted Documents Documents from other B&W organizations or other suppliers are forwarded to SFiiLWS and/or the support engineering organization and from there to Records Management.
Records Management assigns a document number and enters it into the data base. Special process procedures are handled in accordance with section 9. The Document Comment Form (DCF) is used for supplier document review / approval and as a release form.
l
t B&W Fuel Comparty
,m SFHLWS PRODUCT LINE QA MANUAL
/
PAGE OF SECTION SUBJECT REYlSION NO.
NO.
6 DOCUMENT CONTROL 01 i,
6.9.
Reference Procedures
' I NPD Record Management Program NPG 0310 05 Product Numbering NPG 0310 38 llistorical Documents List (IIDL)
NPG 0402 01 Preparing and Processing NPD Prepared Calculations.
NPG 0403 Il Technical Document Signatures.
NPG 0405 21 Change Authorization (CA)
NPG 0412 55 Design Specifications / Requirements Documents.
NPG 0412 58 Processing NPD Prepared Detail Design Documents.
NPG-0412 59 Engineering Information Record / Technical Data Record.
NPG 0412 66 Release of Product Documentation.
NPG 0412 67 Processing Technical Documents from Suppliers and Customers.
NPG 041412 Preparing Licensing Documents.
NPG 050414 NPD Prepared Site Support Documents NOP 1303 24 Special Case Transmittal of Technical Information NP 041413 Processing Licensing Documents.
NPG 0503 07 Field Change Authorization.
NPG 1303 07 Preparing and Processing Administrative Piocedures.
NPG 130315 Control of NPD Manuals.
NPG 130317 Operating Instructions.
NPG 13t t 01
- NPD Filing System and Records Retention Program.
l t
B&W Fuel Company SFHLWS PRO. DUCT LINE QA MANUAL
,o
()T i
? AGE OF SECTION SUBJECT REVISION NO.
NO.
7 CONTROL OF PURCHASED ITEMS 01 COMPLETE REYlSION 7.1.
General B&W organizations and others rosy supply SFilLWS Product Line safety related components.
They have QA programs that control the manufacture of these Product Line items. These programs are approved by NPD QA and periodic audits are performed to assess their implementation. The applicability of the B&W Fuel Co. quality specification is established in the procurement documents. Any procedures requiring document submittal to and approval by the B&W Fuct Co. are also identified in the procuremerit package.
Some product line non safety components may be provided by suppliers. Procurement of these non safety related items are contro!!cd by the requirements imposed by the customers contract that are ref acted in the procurement documents.
7.2. Source Surveillsnee and Documentsrv Evidence Quality control surveillance as described in section 2.4. will be performed by NPD QA when requested by the SFilLWS QA Representative. When all requirements have been satisfied and the product is ready for shipm:nt, the, QA data package is reviewed for completeness and acceptability by the SFilLWS QA Representative. A Certificate of Conformance (COC) is prenared to indicate that documentary evidence exists t; s crify that material and items conform to th: procurement document. The COC is signed by the SFilLWS QA Representative after it has been determined that procurement and documentary requirementr have been met and are acceptable.
O
B&W Fuel Company SFHLWS PRO, DUCT LINE QA MANUAL SECTION SUBJECT REVISION NO.
NO.
7 CONTROL OF PURCilASED ITEMS 01 i
Deference Procedy,tg.1 Quality Assurance Program Requirement Specification 09 1212 for Nuclear Equipment.
Processing Technical Documents From Suppliers and NPG 0412 67 Customers.
NPG 121212 Quality Assurance Data Package and NPD Certificate of NPG-1705 03 Conformance.
QA R: view of NPD Qn Packages NPG 170516 NPG 1708-08
- Quality Control Surveillance
(,
QA Audits of NPD Suppliers NPG 1719 22 l
Quality Assurance Requirements for Research and 09 1427 Development l
l l
l l
B&W Fuel Company n
SFHLWS PRO, DUCT LINE QA MANUAL
/
PAGE
' 0F SECTioN SUBJECT REVISION NO NO.
8 IDENTIFICATION AND CONTROL OF htATERIALS & ITEhtS 01 i
COhtPLETE REVISION 8.1.
General Suppliers are required to have procedures to describe the criteria for establishing part identification requirements. Necessary controls for maintaining identification and traceabi.ity of materials and items from receipt by the supplier through storage, processing, and assembly to final acceptance of the completed items by the B&W Fuel Co. SFilLWS Product Line are defined. Where physical identification is neither practical nor sufficient, physical separation, procedural control, or other means are allowed, htaterials and items are identified by heat or serial r: umbers, or other means, either on the item or on records traceable to it.
Serial numbers to be used on fuel assemblies, control rod assemblics, etc., are assigned and transmitted to the supplier via PO or PA. Acknowledgment by the supplier ensures these instructions are understood.
81 1 art Number Identification part numbers are assigned to all manufactured items within the SFilLWS
'd P.oduct Line.
81 Imolementation SFilLWS Product Line procurement documents establish requirements for identification and cor. trol of materials and items.
la accordance with the requirements specified in procurement documents, NPD QA evaluates the supplier's identification and control system for adequacy, through surveillance visits and audits. These visits and audits measure and overcheck the following:
a.
The supplier has a system to identify and control materials and items from their receipt through fabrication and shipping.
b.
The supplier implements an identification and control system that provides traceability to original material, reports, and documents that satisfy the requirements of applicable standards and specifications.
- c.. The supplier maintains the required identity and controls matetials, parts, and components during manufacture and shipping of their products, d.
Identification methods used are not detrimental to the product.
c.
Non conforming items are identified and segregated from acceptable items.
A f.
Proper identification of materials and items is verified before their release for assembly or shipping.
h B&W Fuel Company SFHLWS PRO. DUCT LINE QA MANUAL 2
PAGE OF I
i SECTION SUBJECT REVISION
]
NO.
NO.
l 8
IDENTIFICATION AND CONTROL OF MATERIALS & ITEMS 01 j
8.4.
Reference Procedures 09 1212
- Quality Assurance Program Requirement 3pe';ification for Nuclear Equipment.
l l
NPG 0310 05 Product Numbering.
NPG 1719 22 i
I
{
I I
l l
i i
I i
I f
r P
I
]
I
B&W Fuel Company n
SFHLWS PRODUCT LINE QA MANUAL PAGE
' OF SECTION SUBJECT RgytsrON NO.
NO.
9 CONTROL OF PROCESSES 01 1
COMPLETE REVISION 9.l.
General When required, the procurement documents (including the applicable specifications) stipulate that the supplier establish procedures to control special processes for manufacturing SFIILWS Product Line hardware. Special processes include such work as welding, bra:Ing, heat treating, and non destructive examination.
91 Imolementation Procurement documents (section 4) establish requirements for control and approval of special processes as necessary. NDE procedures are approved by qualified personnel.
Technical and NDE procedures, such as welding, heat treating and x ray, are approved by SFIILWS. Cleaning is considered to be a technical special process when exceptional and unusual care in cleaning is required by the procurement documents. Special manufacturing procedures are controlled as follows:
(9 s.
All special processes shall be performed in accordance with written procedures which Q) have been qualified for their intended purpose, b.
Personnel responsible for control of special processes shall be qualified and, when necessary, cert'fied to applicable standards.
l l
c.
Procedures and procedure changes for special processes shall be submitted to and l
approved by appropriately qualified B&W Fuel Co. Personnel.
d.
Application of approved special proc,4s procedures shall be subject to audit.
pd
4 B&W Fuel Company SFHLWS PRODUCT LINE QA MANUAL 2
2 PAGE 0F SECTION SUBJECT REvis!ON NO.
NO 9
CONTROL OF PROCESSES 01 9.3.
Reference Procedures and Documents I
09 1212 Quality Assurance Program Requirements Spacification for Nuclear Equipment.
l NPO 0412 67 Processing Technical Documents from Suppliers and Customers.
NPO 1719 22
84W Fuel Company p)
SFHLWS PRO. DUCT LINE QA MANUAL I
\\,/
PAGE OF SECTION SUBJECT REVISION NO NO.
10 INSPECTION 01 J0.1. General The technical documents released to the suppliers identify the inspection requirements and methods to be used in manufacturing SFilLWS Psoduct Line products. Inspection procedures are reviewc3 and periodic NPD QA audits are conducted to verify compliance.
10.2. Imoleraentation The technical specifications and drawings provide detail requirements for inspection and examination of items durin8 manufacturing. These documents require the supplier to submit special inspection procedures and results to BAW Fuct Co. engineers for review if applicable to the order. These requirements also specify the type of inspection, acceptanec standtrds and frequency of examination. Deviations based on inspection resu!ts are reviewed by B&W Fuct Co. engineering. Supplier surveillance is authorized by the BAW Fuel Co. and is conducted by qualified and independent NPD or contract personnel when 01 required by the procurement documents.
i I
}
l v
l
\\
B&W Fuel Comparty SFHLWS PRO. DUCT LINE QA MANUAL 2
A x
PAGE OF SECTION SUBJECT REVISION NO.
NO.
10 INSPECTION 01 10.3. Reference Procedures and Documents 09 1212 Quality Assurance Program Requircraent Specification for Nuclear Equipment.
Processing Technical Documents from Suppliers and NPG 0412 67 Custouers.
1 i
NPG 1705 03
- Quality Assurance Data Package and NPD Certificate of i
Conformtace.
l l
NPG 1708 08 Quality Control Surveillance.
NPG 1719 22 QA Audits of NPD Supplicts 01 i
l l
r t
I
B&W Fuel Company n
SFHLWS PRODUCT LINE QA MANUAL PAGE OF SECil0N SUBJECT REVISION NO.
NO.
It TEST CONTROL 01 11.1. General Testing will t,c used when engineering judgment, codes, standards, or regulations indicate that design verification must be substantiated by testing or for product development. A written test program prepared by the responsible design organization describing all required tests it used to ensure conformance with the desig.: requirement.
11 1 Develooment er Prototvoe Tests Development or prototype tests are usually performed at a research facility. Deselopment testing is generally performed to establish new component design, verify design, or establish or verify new design methods. Prototype testing is performed when design verification is required in lieu of other verification methods; however, prototype testing is also used for product development.
SFitLWS or its supporting engineering organization prepares the test requirement documents
,m including scope and quality assurance requirements. This information is transmitted to the (V) testing organization in accordance with procurement procedures. The testing organization prepares the test plan and performs the test after receipt of engineering approval.
O m
B&W Fuel Company SFHLWS PRO. DUCT LINE QA MANUAL s
2 2
PAGE OF SECTION SUBJECT RIVISION NO.
No.
j 11 TEST CONTROL 01 l
11.3. Reference Procedures and Documents 09 1212 Quality Assurance Program Requirement Specification for Nuclear Equipment.
09 1427 Quality Assurance Requirements for Research and Development.
NPG.0405 30 Design Verification Testing.
i NPG 121212 Procurement Documents.
i l
l l
l i
l d
i i
i i
.uAA
B&W Fuel Comparty o
SFHLWS PRODUCT LINE QA MANUAL PAGE.
' OF
$ECTION SUBJECT Revision NO NO 12 CONTROI, OF hfEASUREhfENT AND TEST EQUIPMENT 01 12.1. General SFili,WS Product Line procurement documents regelre suppliers to provide an et'fective operatioaal system for maintenance, calibration, and selection of test and measurement equipment used in inspection, test, and manufacturing activities affecting quality of supply related components.
H,2. Cslibration When required by the procurement documents, the supplier shall use measurement and test equipment identified by special number and calibrated using written procedures. Records mutt be maintained indicating the last calibratiori date and the duc date. Calibration duc dates must be visibla and traceable to each item. Procedures must also be established for 01 inspection and calibration of tools, gauges and test equipment to known standards at specifi$d intervals. These requirements do not imply a need for special calibration and control measures for rulers, tapes, levels, and other such devices.
b(
i l
i
t B&W Fuel Company
$FHLWS PRO, DUCT LINE QA MANUAL t
I PAGE OF 1
SECTION SUSJECT REVISION i
NO.
NO-t 12 CONTROL OF MEASUREMEN" AND TEST EQUIPMENT 01 i
i l
M Jeference Procedures and Documert_p, l
1 09 1212
- Quality Assurance Program Requirement Specifiention i
for Nuclear Equipment, l
l l
i d
l l
1 l
- i j
i i
i i
4
)
i A
I i
i I
t I
l
,r.-.--
.n-
-.n---r.,.--_-_
..c.
,,. ~. -, - -, _ -.... - -, - - - - - - - - ~ - -
,--,.--,,,----------,-r--
B&W Fuel Company O)
SFHLWS PRO. DUCT LINE QA MANUAL i
\\,/
PAGE OF SECTION SUB)[CT PEYlSION l NO.
NO 13 ~
li ANDLING, STORAGE AND 'JillPPING 01 13.1. General Suppliers of ?afety related components are required to develop procedures to control handling, storbe, shipping, cleaning, and preservation of material and items to prevent e
damage or deterio.ation. Special protective environments, such as specific moisture content levels, are specified and provided as necessary.
4 13 1 Evalustion and Imolementstion Procurement documents iderttify items that have specific cleaning, handling, preservation, storage, and shipping requirements, and specify handling or marking requirements.
The suppliers handling, cleaning, preservation, storage, and chipping systems are periodically audited by the NPD QA representative in accordance with B&W Fuel Company requirements. Measures are also periodically monitored during fabrication and storage (prior to shipping) to ensure that special specifications or procurement PuthoriZalion requirements are implemented to preclude damage, loss, or deterioration. When the p) technical documents require special procedures for handling, storage and shipping, they are gV reviewed and approved by SFillWI prior to use.
l
B&W Fuel Company SFHLWS PRO. DUCT LINE QA MANUAL O-2 I
Paty or
$[CTION SUBJCCT REVISIC N 13 IIANDLING, STORAGE AND SillPPING
~ [. "
1 13 3 Reference Procedures and boeuments 09 1212 Quality Assurance Program Requir: ment Specification for Nuclear Equipment.
NPG 0412 55 Design Specification / Requirements Documents.
NPG 0412 67 Processing Technical Documents from Suppliers and Customers, NPG 1719 22
- QA Audits of Suppliers.
I l
B&W Fuel Compe:rf o
SFHLWS PRO. DUCT LINE QA MANUAL
)
'q j '
PAGE
, OF
$ECTION F'18)[CT REYtSiON No.
No.
14 INSPECTION, TEST AND OPERATING STATUL 01 14.1. General Suppliers of saf-ty related components are required to have in place in their QA manual and internal proceduren, measures that will indicate the status of inspections and tests performed on recc.ved and manufactured items. The internal procedures define the inspect.
lon forms and idenilfication methods to be ustd la inspecting fuel product line items.
Through periodic audits and surveillance visits, NPD QA, at the request of the 8&W Fuel 01 Co. measures and overchecks this program.
1 This program requires appropriate controls to allow determination of the status of materials, parts, or assemblics throughout the manufacturing cycle. Appropriate tags, cards, etc., are used during receiving, processing and final inspection to ensure quality requirements are identified. The results of th,tse tests and czaminations are documented and retained in aesordance with a storage, retention and retrieval system that mects the 01 requirements of ANSI N45.2.9 l?74 and NQA.I.1986 and addenda.
i 1
1
(
l
B&W Fuel Company SFHLWS PRODUCT LINE QA MANUAL O
PAGE OF SECTION SUBJECT REVISION NO.
NO.
14 INSPECTION, TEST AND OPER ATING STATUS 01 i
14.2. Reference Procedures 09 1212
- Quality Assurance Program Requirement Specification for Nuclear Equipment NPG 1719 22 QA Audits or Suppliers f
i l
i I
l l
l
\\
i
B&W Fuel Company o
SFHLWS PRO. DUCT LINE QA MANUAL PAGE OF SECTION SUBJECT REVISION NO.
NO.
15 CONTROL OF NON CONFORh11NG ITEhtS 01 COh1PLETE REVISION 15.1. General hicasures are established to control the quality of material and items that do not conform to procurement document requirements. These measures include (as appropr'ste) procedures for identification, documentation, segregation, disposition of nonconforming items, and notification to affected organizations. Non conformances are reviewed and accepted or rejected in accordance with this section.
15.2. Internal Non conformances Non conformances detected within the B&W Fuel Co. as a result of audits or found during review of documents are corrected in accordance with the procedures shown on page 3 of this section.
15.2.1. Internal Defleiency Recort (IDR) and Corrective Action Reavest (CAR)
IDRs and CARS are initiated by either NPD QA or B&W Fuel Co. QA personnel during the (Vp) normal exercise of their duties to highlight deficiencies noted in quality related methods, procedures, policies, standards, proposals, or other documents that have been proposed, generated, or issued by the B&W Fuel Co.
15.2.2. Audit Findine (AF)
AFs are initiated by NPD QA or B&W Fuel Co. QA to identify non conformances.
Corrective action is recommended to preclude recurrence of each finding.
Findings and recommended resolutions are discussed and presented to all concerned audii participants. A formal audit report, including AFs, is prepared after the audit. Reply to the findings is requested within a specified time. The report is sent to the manager of the audited organization, General hianager D&W Fue! Co., NPD QA hianager, and other concerned personnel.
Responses to audit findings are evaluated by an auditor or team leader. NPD or B&W Fuel Co. QA determines the need to re audit the organization to verify implementation of the proposed corrective action. AFs are closed upor QA verification of completion of all actions contained in the finding response. The effectiveness of proposed corrective action is evaluated during subsequent audits.
15.2.3. Reoortine of Safety Concerns B&W Fuel Co. personnel who discover a potential ;afety concern complete a preliminary report of safety concerns (PSC) form. This PSC is evaluated arid an evaluation report prepared. The report is provided to the concerned departments to determ ne whe'her the s
/
potential safety concern is reportable under 10CFR PART 50.55(c) or Part 21. The B&W Fuel Co. through NPD informs the NRC and the owner concurrently when it is decided that a potential significant deficiency exists, or informs the NRC once it is decided that a substantial safety hazard exists.
B&W Fuel Company q
SFHLWS PRO, DUCT LINE QA MANUAL
,/
PAGE 0F 2
SECTION SUBJECT REVISION NO.
rv0.
15 CONTROL OF NON CONFORhilNG iTEhtS 01 15.2.4. Desien Deficiency Recoru Design Deficiency Reports (DDR) are issued to document any meaningful deficiency (as determined by the Technical hfanager) discovered in any released NPD prepared design input / output document. The DDR defines the action to correct the error and ary subsequent corrective action.
15.3. Sucolier Non conformance Suppliers non conformance reports are initiated in one of two ways: (1) by the supplier due to a contract variation that violates the requirements of the B&W Fuel Co. procurement documents, specifications, or approved supplier drawings and procedures (CVAR); (2) by NPD QA as a result of findings during auditing of the supplier's QA system (AF).
15.3.1. Contrac* Variation Acoroval Reauest (CV@
The CVAR is a controlled document used to approve or disapprove the disposition of those (nv) items identified by the supplier as not being in compliance with the technical requirements of the procurement package or B&W Fuel Co. approved supplier documents. CVARs are e,ssigned a controlled number and are processed for approval in accordance with procedures.
15.3.2. Audit Finding An audit finding (AF) for supplier audits is prepared and processed in accordance with procedures. All findings are discussed and explained to audit participants. A copy of the AF is left with the supplier and followed up with a formal audit report.
15.4 Site Problems SFilLWS Project hianagers are responsible for resolving site problems. Site problems are handled in accordance with established procedures. For example, the repair plan for damaged components is prepared by SFilLWS or its support engineering organization, forwarded to the organization responsit.lc. for the repair, who then repairs the components and certifies its work to be in accordarice with the repair plan. The Project hianager is responsibic for tracking and expediting the repair.
l l'v l
L
1 B&W Fuel Company SFHLWS PRODUCT LINE QA MANUAL 3
3
\\
PAGE OF SECTION SUBJECT REVISION NO.
NO.
15 CONTROL OF NON CONFORMING ITEMS 01 15.5. Reference Procedures Contract Variation Approval Requests.
NPG 0405 05 Change Authorization (CA).
NPG 0405 21 Internal Deficiency Report / Restraint Order /
NPG 1703 01 Corrective Action Request.
Processing Safety Concerns.
NPG 1707 01 NPG 1717 02
- Reporting and Resolving Internally Identified Design Deficiencies.
NPG 1719 21 QA Audits of NPD Suppliers.
NPG 1719 22 i
B&W Fuel Company o
SFHLWS PROpVCT LINE QA MANUAL PAGE OF SECTION SUBJECT REVISION NO.
NO.
16 CORRECTIVE ACTION 01 16.1. General Conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material and items, and non conformances, are promptly identified and corrected.
Measures have been established to assure that:
a.
Each identified problem is evaluated sufficiently to determine the cause, b.
A remedy is defined as soon as practical.
c.
Actions are defined to prevent recurrence of the quality non conformance, d.
Follow up ection is taken to verify implementation of this corrective action.
c.
If the cause of the deficiency is a random event (operator error) remedial action is g
- applied, f.
The resolutions recommended to correct the deficiency are adequate and will fulfill the requirements of the QA program.
If it is determined that action has not been initiated to determine the "root' cause of the problem and corrected to preclude recurrence, the NPD or SFHLWS QA Representative will issue a Corrective Action Request (CAR) for appropriate action. NPD or B&W Fuel Co. QA follows up to verify the effectiveness of the corrective action taken. In addition, corrective action meetings are conducted with the supplier to review deviations. Appropriate action is assigned during these meetings to resolve outstanding items.
16.2. Internal Corrective ActioD1 NPD or B&W Fuel Co. QA furnishes deficiency reports to appropriate levels of management and requests corrective action where necessary.
l Deficiencies disclosed by internal, customer or agency audits require corrective action to preclude recurrence of the noted deficiencies. The proper application of corrective action is evaluated by follow up audits by the auditing agency that performed the initial audit.
t l
i I
l l
m.
-~+m
B&W Fuel Company
/m SFHLWS PRO, DUCT LINE QA MANUAL e
1
(_,/
2 3
PAGE OF SECTION SUBJECT REVISION NO.
NO.
16 CORRECTIVE ACTION 01 16.3. Sucolier Corrective Actions The need for supplier corrective action is identified as a result of QA audits and engineering review of process and material deviations. Procurement documents impose corrective action requirements to ensure resolution in a manner acceptable to Quality Assura nce. NPD QA audits are used to monitor the suppliers performance to determine if corrective actions comply with the requirements of the procurement documents.
The timely accomplishment of appropriate supplier corrective action is ensured through actions described in estabHshed procedures covering the use of IDRs restraint orders, and A Fs. Sub contractor restraints are imposed by or through the first tier suppliers.
16.4. Field Channe If corrective action requires a change to the design of items located at the plant site, a Field Change Authorization is initiated to implement, or to recommend implementation of the change. For details see referenced procedures, b
16.5. Corrective Action Record Each of the processes noted above includes requirements for generating and documenting corrective action. NPD or D&W Fuel Co. QA reviews these documents to monitor corrective actions and maintains files to record their status.
16.6. Sinnificant Ouali y Problems t
Problems that are characterized by one or more of the following criteria are considered to be significant and require action to resolve as described in Section 16.1:
a.
Safety implications b.
Recurring Deficiencies c.
Need for control of further processing, delivery installation, or operation of an item or process until proper disposition of a non.conformance, deficiency, er unsatisfactory condition has occurred.
d.
Failure of organizations to take effective or timely corrective action.
c.
Violation of applicable stand rds, codes, regulations, or contractual obligations, f.
An error in a design document which causes deficiencies in items or services.
n I
\\
V g.
An error in an analytical input, method assumption or calculation which causes extensive documentation rework to correct.
t
B&W Fuel Company fen SFHLWS PRO, DUCT LINE QA MANUAL
\\
PAGE OF SECTION SUBJECT REVISION NO.
NO.
16 CORRECTIVE ACTION 01 Significant quality problems are reported to appropriate management and to the cu,:tomer as necessary by the Project Manager.
16.6. Reference Procedures NPG 0405 05 Contract Variation Approval Request.
NPG 0405 21 Change Authorization (CA).
NPG 0405 22 Design Reviews.
NPG 0503 07 Field Change Authorization.
NPG 1703 01 Internal Deficiency Report / Restraint Order / Corrective Action Request.
NPG-1707 01 Processing Safety Concerns.
NPG 1717 02 Reporting and Resolving Internally Identified Design Deficiencies.
NPG 1719 21
- QA Audits of NPD NPG 1719 22 QA Audits of Suppliers i
n
B&W Fuel Corapany c
SFHLWS PRO, DUCT LINE QA MANUAL j
PAGE OF SECTION SUBJECT REVISION NO.
NO.
17 QUALITY ASSURANCE RECORDS 01 17.1. General Procedures are established to collect, retain, and/or distribute records providing evidence that the design, procurement, fabrication, and testing activities comply with quality requirements.
The flistorical Document List (ilDL) is a document list that provides identification of approved safety related design documents. It is updated as documents are approved or revised so as to orovide a current list of approved safety related contract documents.
Records are collected during design and procurement to furnish documentary evidence of the quality of items and of activities affecting quality. These records are identifiable, retrievable, legible a.ad are maintained in facilitics that provide a suitable environment to minimize deterioration or damage, and to prevent loss. Original documents are microfilmed and copics are maintained in separate remote locations for permanent records. The records are maintained and identified in accordance with the Records Management Manual. QA o
records provide sufficient information to relate to the item or items of activity to which (D
)
they apply.
17.2. Resoonsibility The B&W Fuel Co. has contracted with NPD Nuclear Operations and Administration to 01 receive, store, retrieve, and dispose of QA records.
17 3.
Quality Records During the design phase, quality related records are retained to document design activities.
These records may include design calculations, reports, specificctions, and contract drawings. These records are transferred to permanent storage in accordance with B&W Fuel Co. document retention policy outlined in section 17.4.
Procurement documents require supplicts to establish and maintain quality related records such as inspection and test records; work perfo7mance and material analysis records; qualification records of personnel, procedures, and equipment; calibration procedures; and calibration reports. Procurement documents identify which records are to be supplied or retained by the supplier tubject to traceability and recovery requirements.
O v
B&W Fuel Company SFHLWS PRODUCT LINE QA MANUAL q]
PAGE
' 0F REVISION SUBJECT SECTION NO.
NO.
01 17 QUALITY ASSURANCE RECORDS 17.4. Permanent Records All safety related records to include receiving inspection, packaging, shipping, inspection 01 procedures and process qualification records for special processes produced during the All process of design and procurement activities are considered to be permanent records.
of the owner required permanent re ords are provided to the plant owner or maintained for the life of the plant (40 years or more) in accordance with the contract requirements.
Records are preserved and retained in the original form or in micro form and meet the requirements of ANSI N45.2.91974 and NQA l.1986.
, oi 17.5.
Access to and Control of Files Records Management personnel conduct all activitics related to the original filing, withdrawing, refiling, and other processing of records.
a I
l l
l l
l B&W Fuel Company j
(m SFHLWS PRODUCT LINE QA MANUAL
\\
PAGE OF 3
SECTION SUBJECT REVISION NO.
NO.
17 QUALITY ASSURANCE RECORDS 01 17.6. Reference Procedures IEl NPD Records Management Program.
09 1212 Quality Assurance Program Requirement Specification for Nuclear Equipment.
NPG 0310 38 Historical Documents List (IIDL).
Processing NPD Prepared Calculations.
I NPG 0402 01 NPG 0412-55 Design Specifications / Requirements Documents.
Processing NPD Detail Design Documents.
NPG 0412 58 NPG 0412 66 Release of Product Documentation.
NPG 131101 NPD Filing System and Records Retention Program.
NPG-1705 03
- QA Data Package and NPD Certificate of Conformance.
NPG 1707 01 Processing Safety Concerns.
NPG 1311 10 Retention of Computer and Data Processing 01 input / Output Media I
i l
l
- m B&W Fuel Company gm (v)
SFHLWS PRODUCT LINE QA MANUAL 3
PAGE OF REVISION SUBJECT SECTION NO.
NO.
18 AUDITS 01 18.1. General The audit program comprises a comprehensive system of planned periodic audits to verify compliance with all aspects of the SFilLWS Product Line QAP and to determine the continuing effectiveness of the program. The a'.:dits are performed utilizing written instructions and appropriate check lists. Audit personnel have no direct responsibility in the areas being audited, and are trained and qualified in accordance with the requirements of ANSI /AShfE N45.2.23, and NQA-1. Follow up action includ!ng re nudits of the deficient 01 areas, is taken where indicated.
Internal and supplier audits are condected according to written instructions which establish the scheduling, preparation, execution, reporting, and follow up methods to be used in implementing the audit program. Audios conducted under the QA md8t program include an objective evaluation of quality related practi.cs, procedures, and insti. tion; the effectiveness of implementation; conformance with policy di cctives; work areas, activities, processes, and items; and the review of quality related documents and records.
'3 Requirements fur audit preparation include review of available data as to requirements and
,j performance and the preparation of check lists to provide a base for evaluating test,
\\
inspection, and system adequacy. Continuing analysis of the audit information is performed to indicate any trend in quality or the effectiveness of the SFliLWS QA program.
Significant findings are reported to management.
18.2. Internal Auditi All eighteen (18) sections of the SFilLWS Product Line QA hfariual are audited annually by 01 an auditor having no responsibilities in the area being audited. These audits of SFliLWS Product Line activities are scheduled at least once in a calendar year. Reports on findings from internal audits are provided to the managers of the areas audited and to the General hianager of the B&W Fuel Co. for review, analysis, and direction. hianagers in the audited areas provide written responses to the audit findings and follow up is conducted by the SFilLWS QA Representative to ensure implementation of appropriate corrective actions.
When necessary, the follow up includes re auditing the open audit findings. The program assures the availability of personnel trained to the requirements of ANSI /AShfE N45.2.23 01 and NQA 1, for the accomplishment of audits and provides the record keeping to assure ready access to the udit schedule and action item status for identified action items.
18.3. Sucolier Audits These audits Suppliers are audited to determine the effectiveness of their QA programs.
are conducted during procurement activities to provide a continuing evaluation of the supplier's QA program.
v
B&W Fuel Company (3
SFHLWS PRODUCT LINE QA MANUAL
/
PAGE OF SECTION SUBJECT REVISION NO.
NO.
18 AUDITS 01 i
Audit frequency is based on written criteria that incorporate the safety classification, complexity, and quality of the item. Reports of findings frorn audits are provided and responses to the findings are required. Open findings are closed when the supplier can demonstrate effective corrective action in the area of an open finding, Audit reports, responses, and their evaluation provide input for maintenance of the approved supplier list, which provides a re:sdy reference to the suppliers QA program.
Procurement documents require the supplier to have administrative procedures requiring the performance of planned and periodic internal and vendor audits to verify compliance with its and its vendors' quality programs and with the QA specification.
18.4. Audit Records Audit records are maintained as QA records. These include: audit plans, internal and supplier audit reports, audit findings which contain deficiencies noted and recommendations, replies to audit reports with follow up verification of resulting corrective actions, and audit personnel qualification : ecords.
18.5. Site Audits Site audits of B&W Fuel Co. activities will be performed in accordance with the customer requirements. When performed, they will be conducted as early in the life of the activity as practical. They also will be conducted on intervals consistent with the schedule for accomplishing the activity and commensurate with the status and importance of the 01 activity.
I L
l B&W Fuel Company SFHLWS PRO, DUCT LINE QA MANUAL O-PAGE OF l
N.CTION SUBJECT REVISION NO.
NO.
18 AUDITS 01 18.6. Reference Procedures 09 1212
- Quality Assurance Program Requirement Specification for Nuclear Equipment.
NPG 1719 21 QA Audits of NPD Activities.
QA Audits of Suppliers.
NPG 1719 22 A
B&W Fuel Company SFHLWS PR0pVCT LINE QA MANUAL m
7 k
PAGE '
0F 6
SECTION SUBJECT REVISION NO.
NO.
APPENDIN ACRONYMS / DEFINITIONS 01 ADL A' alicable Document List AF Audit Finding ANI Authorized Nuclear Inspector ANSI American National Standards Institute ASME American Society of Meciianical Engineers B&W Dabcock & Wilcox CA Change Authorization CAR Corrective Action Request CCRL Core Contract Requirements List CFR Code of Federal Regulations CNFP Commercial Nuclear Fuel Plant COC Certificate of Conformance CVAR Contract Variation Approval Request DCF Document Comment Form DDR Design Deficiency Report DOE Depcrtment of Energy DRN Document Release Notice E SPEC Equipment Specification FCA Field Change Authorization llDL llistorical Document List IDR Internal Deficiency Report NCR Nonconformance Report g
NDE Nondestructive Examination
B&W Fuel Company SFHLWS PRO, DUCT LINE QA MANUAL SECTION SUBJECT REVISION NO.
NO.
APPENDIN ACRONYMS /D8FINITIONS 01 NOAA Nuclear Operations & Administration NPD Nuclear Power Division NRC Nuclear Regulatory Commission NSC Nuclear Steam Core 01 Operating Instructions PA Procurement Authorization Phi Project hianager/ Project hianagement PO Purchase Order s
PSC Preliminary Safety Concern QA Quality Assurance QAP Quality Assurance Program QC Quality Control i
QCS Quality Control Surveillance R&DD Research and Development Division RG Regulatory Guide i
RO Restraint Order SFilLWS Spent Fuel & liigh Level Waste Services SPR Site Problem Report l
V P&GN1 Vice President and General hianager l
t
_.. _ ~ _ _ _ -. _... _ _ _ _ _ __,
.-____.m.._.m_-_,-~_
. ~.-. - -, - - -, _. - - _ - - -. _ - - - _. - - -. - - -
B&W Fuel Company o
SFHLWS PRODUCT LINE QA MANUAL 6
f PAGE OF SECTION SUBJECT REVISION NO.
NO.
APPENDIN ACRONYMS / DEFINITIONS 01 Audit A planned and documented activity performed to determine by investigation, examination, or evaluation of objective evidence tbc adequacy of and compliance with established procedures, instructions, drawings, and other applicabic documents, and the effectiveness of implementation. An audit should not be confused,,
with surveillance or inspection activities performed for the sole purpose of process control or product acceptance.
Audit, pre award A survey is a documented evaluation of an organization's (Survey) ability to perform Code activities as verified by a determination of the adequacy of the organization's quality program and by a review of the implementation of that program at the location of the work.
Cognizant Engineer An engineer who has specialized work experience and expcrtise in a given system, analyses, or hardware discipline.
- \\
Conceptual Design An idea for a new product or major redesign of an existing product that has been reduced to paper in the form of notes / sketches in sufficient detail to convey the intent and basic principles involved, the major interfaces affected, and to allow a reasonable estimate of the technical and cost advantages over existing designs.
Contract Quality Those quality requisites of a product or service Requirements specifically detailed within a contract or made a part there of by reference to specifications or documents, to which a supplier must adhere; and if performing under a QAP, must document his conformance.
Corrective Action Measures taken to rectify cenditions adverse to quality and, where necessary, to preclude repetition. These efforts shall include identification of ' root
- causes of the deficiency and actions taken to present its recurrence.
Designee One who has been designated by a specified principal to act for the principal. Overall responsibility for the consequences of a designee's action remains with the assigned principal.
Deviation A nonconformSnce or departure of a characteristic from specified reqQ ements.
' U t
l l
L
B&W Fuel Company 73 SFHLWS PRO. DUCT LINE QA MANUAL 6
/
PAGE OF SECTION SUBJECT REVISION NO.
NO.
APPENDIX ACRONYMS /l>EFINITIONS 01 Disposition Action required to complete either a pre;iminary review or material review decision.
Documentation Any written, graphic, or pictorial information describing, defining, specifying, reporting, or certifying activities, requirements, procedures, or results.
Fabricator /
One who constructs any class of component, part, or Manufacturer appurtenance to meet prescribed design requirements.
Function The ability of a component or system to perform as designed.
Iloidpoint A point at which witnessing of examinations is required by supplier / manufacturer, B&W Fuel Co., ANI, or customer and beyond which point work shall not proceed without the consent cf the supplier / manufacturer's representative, the B&W Fuel Co.,
g}
the ANI, or the customer's representative, (d
In Process inspection of equipment while it is in a fabrication inspection stage.
Inspection Records Recorded data, traceable to a designated inspector and an identifiable item, concerning the results of inspections and/or examinations.
Interchangeability The functional and physical characteristics of an item so that the item would be equivalent in performance and durability, capable of belns used without alteration of the item itself, or any adjoining item except for normal adjustments and does not require selection for fit, performance, or physical characteristics.
Interface Relationship in terms of design and performance between one component or system and another component or system.
Internal Deficiency Report written by QA f or deficiency found during review Report of quality related documents.
Measurement and All devices used to measure, ga:c, test, inspect, Test Equipment diagnose, or otherwise evaluate materials, supplies, and equipment to determine their conformance to specified standards and/Jr requirements.
O
B&W Fuel Company r' N SFHLWS PRODUCT LINE QA MANUAL PAGE OF w
SECTION SUBJECT REYlSION NO.
NO.
APPENDIX ACRONYMS / DEFINITIONS 01 Monitor The act of observing or teaching individuals or organizations to perform according to established work practices, procedures, and instructions by mesas of observation of a units working functions and a review of established procedures.
Nonconformance A deficiency in characteristic, documentation, or procedure that renders the quality of an item or activity unacceptable or indeterminate.
Nondestructive A method of detecting indications of discrepancies with-Examination out destroying the usefulness of the part or material.
Originator One who initiates or prepares a document.
Procurement Contractually binding documents that identify and de-Documents fine the administrative, technical and quality requirements that
/
items or services must meet in order to be considered acceptable s
by the purchaser.
Procurement A document used to transmit procurement information to Authorization tiie procurement function for the purpose of obtaining bids, placing orders, and change orders, etc.
Project Manage-The management function responsible for the contract ment Function with the customer from the proposal stage through the delivery of the end products. In the cases where the work is internally funded by B&W, the management function controlling the funds is the PM function.
Public Law 96 295 Section 203 of Public Law 96 295 enacted on June 30,1980, amended Section 223 of the Atomic energy Ac6 of 1954 by assigning responsibilities and naming penalties for certain violations of the Atomb Energy Act that could result in the impairment of a basic component tf a facility licensed under Section 103 or 104b of this act.
Quality Assurance All planned ad systematic actions necessary to provide adequate confidence that all items are manufactured in accordance with applicable requirements including code requiremants.
Quality Assurance An org1nization that determines, implements and enforces (organization)
QA requirements.
V Remedial Action The efforts taken to correct deficient items, with no specific effoit to determine tiie cause or prevent recurrence of the deficiency (see co tctive action),
B&W Fuel Company
]
SFHLWS PRODUCT LINE QA MANUAL 0
0
/
PAGE OF SECTION SUBJECT REVISION NO.
NO.
APPENDi>
ACRONYMS / DEFINITIONS 01 Restraint Order A document that may be used as a 'stop work" or ' hold' order by NPD or B&W Fuel Co. QA when no remedial or corrective action is evident.
Safety related B&W Fuct Compan products, including structures, systems, and items components and their associated design that prevent or mitigate the consequences of postulated accidents that could cause undue risk to the health and safety of the public.
Scrap A disposition that may be imposed on a nonconforming item when it has been established that the discrepancy renders the item unfit for its intended use and it is not economically or otherwise feasible to repair or rework it. Scrap may also be excess or damaged material remaining from fabrication operations which is unsuitable for further use.
)
Special Process A process, the results of which are highly dependent on the V
control of the process or the skill of the operators, or both, and la which the specified quality can not be readily determined by inspection or test of the prcduct.
Specifications A concise statement of a set of requirements to be satisfied by a prodact, material, or process indicating whenever appropriate the means by which it may be determined whether the requirements given are satisfied.
Spent Fuel & liigh Refers to engineering, project management, manufacturing, or Level Waste Services services associated with spent fuel or high level waste Product Line contracts or contract research as conducted by the office of SFilLWS.
Subcontractor /
An organization that performs part of the work for a subtler Supplier supplier or contractor who has originally been awarded a Contract.
Supplict (Vendor)
Any individual or organization who furnishes items or services to a procurement document. An all inclusive term used in place of any of the following: Vendor, seller, contractor, subcontractor, fabric:stor, consultant, and subtler levels. The. major supplier is the CNFP. Other suppliers may be used at the option of Project Management.
G/
Waiver Written authorization to depart from some specified requirement.
Witness To observe performance.
._