Forwards Corrected Page to Rept of Startup Testing for Facility Cycle 10.Predicted Values for Full Power Should Have Been Reported as 1302,not 1303
ML20204G541
Person / Time
Site: Calvert Cliffs 
Issue date: 10/13/1988
From: Mihalcik J
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NEU-88-308, NUDOCS 8810240146
Download: ML20204G541 (2)


Text

_ _ _ _ _ _ - _ _

BALTIMORE OAS AND ELECTRIC L

CHARLES CENTER P.O. BOX 1475 BALTIMORE. MARYLAND 21203 NUCLEAR ENGINEERING SERVICES DEPARTMENT cALvtat cons NucttAn Powtm Ptawi LUsSY, WAmVLANO 904$7

[

October 13, 1988 NEU 88 308 i

U. S. Nucleat Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk i

SUBJ ECT:

Calvert Cliffs Nucler.r Power Plant Unit No. 1; Docket No. 50 317 Correction to Reoort of Ctartun Testine for Unit 1 Cvele 10 L

REFERENCES:

(a)

Letter, J. A. Tierna7 (BC6E) to Document Control Desk l

(NRC), dated Septerloer 9, 1988, "Calvert Cliffs Nuclear l

2 Power Plant Unit

.a.

1 Docket No. 50 317, Report of Startup Testing for Unit 1 Cycle 10" i

t i

j Centlemen:

l i

Reference (a) contains a data reversal and a typographical error in Table 1 l

l Critical Boron Heasurements. The predicted and measured values for CEA Croups 1 l

through 5 Inserted Zero Power, are reversed. Also the predicted value for Full Power should have been reported as 1302, not 1303. All analytical work and j

review / acceptance criteria were performed using the correct values. Attached is the corrected page.

l Very truly yours, O

G L.

p J.'A.'Mihaleik Principal Engineer-Nuclear Engireering 2

9 JAM / Int

(

i l

Attachment r

cc:

D. A. Brune, Esquire p

[

J. E. Silberg, Esquire

(

(.A*

g, R. A. Capra, NRC

%4 4td (/[d I

l S. A. McNeil, NRC V. T. Russell, NRC i

i D. C. Trimble/V. L. Pritchett, NRC M

t T. Magette, DNR r

J 8810240146 881013 i

i PDR ADOCK 05000317 f

P PDC i

_- ~ __._,.._ _.__._.. _.,.-_.. _...,.. _.,._. _ -

F" "o J 1ABLE 1 iv, CRITICAL BORON MEASUREIGNTS Review Measured Predicted Criteria Zero Power All Rods out, 532 F' 1750 ppm 1780 ppm 150 ppm r

Zero Power CEA Groups 1 through 5 Inserted, 532 F 1411 ppm 1403. ppm 150 ppm l

t i

Full Power CIA Croup 5 105" Withdrawn 1303 ppm 1302 ppm 150 ppm l

l TABLE 2 f

ISOTHERMAL TEMPFRATURE COEFFICIENTS AND POWER COEFFICIENTS IIG Review Measured Predicted Criteria i

Zero. Power, CEA Croup 40.265x10 4 40.222x10~4 10.3x10 4 5 at 100.5 Withdrawn delta rho / F delta rho / F delta rho / F

@ 1750 ppm Full Power, CEA Croup 0.446x10 4 0.402x10'0 10.3x10'4 I

5 at 105" Withdrawn delta rho /*F delta rho / F delta rho / F

@ 1303 ppm POWER COEFFICIENT t

100% Power. CEA Croup 0.904x10'4 0.88x10*4 10.3x10 4 5 at 105" Withdrawn delta rho / F delta rho / F delta rho /*F i

f l

t i

f

[