ML20204D332

From kanterella
Jump to navigation Jump to search
Forwards List of Students from States Selected to Attend 990427-29 multi-agency Radiation Survey & Site Investigation.Purchase Order or Equivalent Document Should Be Submitted as Listed
ML20204D332
Person / Time
Issue date: 03/17/1999
From: Lohaus P
NRC OFFICE OF STATE PROGRAMS (OSP)
To:
GENERAL, MINNESOTA, STATE OF, OHIO, STATE OF, OKLAHOMA, STATE OF, PENNSYLVANIA, COMMONWEALTH OF, WISCONSIN, STATE OF
References
SP-99-014, SP-99-14, NUDOCS 9903240184
Download: ML20204D332 (6)


Text

.

IMO IIIIII ALL AGREEMENT STATES MINNESOTA, OHIO, OKLAHOMA, PENNSYLVANIA, WISCONSIN TRAINING COURSE INFORMATION: ACCEPTANCE TO THE MARSSIM COURSE (H-121)

(SP-99-014 ) is the list of students from the States selected to attend the April 27-29,1999, Multi-agency Radiation Survey and Site Investigation Manual (MARSSIM) Course (H-121).

Please provide the list of students and the instructions (Enclosure 2) to each individual from your program who is on the list. States with students attending this course have agreed to pay travel expenses, and, where designated, the tuition. To cover the tuition expense, each State should submit a purchase order or equivalent document, payable to the U.S. Nuclear Regulatory Commission, to the following address:

Nuclear Regulatory Commission Office of the Chief Financial Officer Attn: Leah P. Tremper Mail Stop T9 E10 Washington, DC 20555 The NRC will, in turn, issue you a bill (invoice), if for any reason your attendeo is unable to attend, please submit to us a written purchase order, or equivalent, to cancel, prior to the starting date of the course.

Course attendees should be encouraged to make travel and lodging arrangements as soon as possible. If for any reason a candidate is unable to attend, please contact us as soon as possible, so that alternative arrangements can be made.

If you have any questions regarding this correspondence, please contact me or the individual named below.

POINT OF CONTACT:

Dennis M. Sollenberger INTERNET:

DMS4@ NRC. GOV TELEPHONE:

(301) 415-2819 FAX:

(301) 415-3502 OriginalSigned By:

PAULH.LOHAUS 9903240184 990317 Paul H. Lohaus, Director PDR STPRQ ESGOEN POR Office of State Programs

Enclosures:

g As stated j

l Distribution:

DlR RF DCD (SP03) o r,

SDroggitis

'l ') k,Tdm)per, OCFO PDR (YES()

BUsilton JPatterson, TTC/HR

% 2 q" GD:vis RReed, TTC/HR f

p ' ' "f hk 8 6f in g File DOCUMENT NAME: G:\\SP98094.DMS T+ receive a copy of this document Indicato in the box: "C" = Copy without attakeni closure "E" = Copy with attachrnent/ enclosure 'N' = No copy OFFICE OSffsg E

OSP E,

04 Phi l

NAME DSollenb8Eder:gd BGUsiltonSMA PHLoha'us DATE 3/ J{/99 3/ f 'l /99 3/f //99 OSP FILE CODE: SP A-4; SP-T-3

e

@ M009

[

It UNITED STATES j

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20E%o001

% y,*/

March 17, 1999 ALL AGREEMENT STATES MINNESOTA, OHIO, OKLAHOMA, PENNSYLVANIA, WISCONSIN l

TRAINING COURSE INFORMATION: ACCEPTANCE TO THE MARSSIM COURSE (H-121)

(SP-99-014) is the list of students from the States selected to attend the April 27-29,1999, Multi-agency Radiation Survey and Site Investigation Manual (MARSSIM) Course (H-121).

Please provide the list of students and the instructions (Enclosure 2) to each individual from your program who is on the list. States with students attending this course have agreed to pay

' ravel expenses, and, where designated, the tuition. To cover the tuition expense, each State should submit a purchase order or equivalent document, payable to the U.S. Nuclear Regulatory Commission, to the following address:

Nuclear Regulatory Commission Office of the Chief Financial Officer Attn: Leah P. Tremper Mail Stop T9 E10 Washington, DC 20555 The NRC wiW, in turn, issue you a bill (invoice). If for any reason your attendee is unable to attend, please submit to us a written purchase order, or equivalent, to cancel, prior to the starting date of the course.

Course attendees should be encouraged to make travel and lodging arrangements as soon as possible. If for any reason a candidate is unable to attend, please contact us as soon as possible, so that alternative arrangements can be made.

If you have any questions reguding this correspondence, please contact me or the individual named below.

POINT OF CONTACT:

Dennis M. Sollenberger INTERNp!T:

DMS4@NRC. GOV TELEPHONE:

(301) 415-2819 FAX:

(301) 415-3502

)

t1 i

)h

)

(W O Paul H. Lohaus, Director Office of State Programs

Enclosures:

As stated i

l STATE PARTICIPANT LIST FOR MULTI-AGENCY RADIATION SURVEY AND SITE INVESTIGATION MANUAL (H-121)

April 26-29,1999 STATE PARTICIPANT (S)

,PA WG Tumo p

g OHC

1. Charles McCracken
1. Space Available Bureau of Radiation Protection
2. Ruth H. Vandegrift
2. Space Available Ohic Departrnent of Health 35 East chestnut Street Colurnbus.OH 43266 OKLAHOMA
1. Mike Broderick
1. Space Available Radiation Managernent Section Departmentof EnvironrnentalQuality 1000 Northeast Tenth Street Oldahoma city. OK 73117 1212 TEXAS.BRC
1. Gary L Smith, Ph.D.
1. Paying Tuition Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin. TX 70756 3189 WAsHNOTON
1. Bruce A. Busby
1. Paying Tuition Division of Radiation Protection Department of Health 7111 Cleanwater Lane. Building #5 P.O. Box 47827 Olympia. WA 98506 7827 ENCLOSURE 1

4 INSTRUCTIONS TO STUDENTS ACCEPTANCE: This is to advise you that those individuals in Enclosure 1 have been accepted for participation in the training course (H-121), " Multi-agency Radiation Survey and Site Investigation Manual (MARSSIM)." This course is scheduled to be presented April 27-29,1999 in Room T3815 at the NRC Professional Development Center, Two White Flint North Building, 11545 Rockville Pike, Rockville, Maryland 20852.

COURSE: The course will be conducted beginning at 8:00 am and end at 4:00 pm each day.

A course outline is attached. Students should bring an engineering or scientific calculator with them.

LODGING AND TRAVEL: Below is a list of motels and hotels in the Rockville area. You should plan to arrive on Monday April 26,1999 and depart on late Thursday April 29,1999 or Friday April 30,1999. Participants must make their own lodging arrangements. Individuals should request a State or government employee rate at the hotels.

HOTELS IN THE ROCKVILLE AREA:

Close by hotels are: Ramada inn (800) 255-1775 1775 Rockville Pike (301) 881-2300 Rockville, MD Doubletree Hotel (800) 222-8733 1750 Rockville Pike (301) 468-1100 Rockville, MD l

ENCLOSURE 2 1->t

r COURSE OUTLINE Multi-aaency Radiation Survev and Site Investiaation Manual (MARSSIM) Course (H-121)

April 27-29,1999

'DATE ILM_E TQPIC Tuesday 4/27/99 8:00 am Welcome, Registration, and Orientation 9:00 am MARSSIM Overview 11:00 am Overview of Radiological Survey Types in Support of Decommissioning-historical Site Assessment Process, Scoping, Characterization, Final Status Surveys 12:00 noon Lunch 1:00 pm Selection and Application of DCGLS 2:30 pm Selection of Background Reference Areas D_ AIR TIME TOPIC Wednesday 4/28/99 8:00 am Detection Sensitivity of Survey Instrumentation-Static and Scan MDCs 10:30 am Classification of Areas by Contamination Potential and Identification of Survey Units 12:00 noon Lunch 1:00 pm Statistical Design of ',.al Status Survey-Wilcox on Rank Sum and Sign Tests; Hot Spot Considerations; Determining Survey Unit Locations 2:30 pm.

- ' Class Exercise: S!atistical Survey Design for Thorium-contaminated Site ENCLOSURE 2 t

COURSE OUTLINE,

Multi-aaency Radiation Survev and Site Investiaation Manual (MARSSIM) Course (H-121)

DATE TIME TOPIC Thursday 4/29/99 8:00 am Integrated Final Status Survey - Survey Activities; Survey Coverage by Area Classification; Investigation Levels 10:00 am Data Quality Assessment - Evaluating Data Set from Class Exercise 12:00 noon Lunch 1:00 pm Data Quality Assessment (Cont.) - Performing Statistical Tests and Elevated Measurement Comparisons; Power Curves 2:30 pm Final Survey Reports 3:00 pm Summary: Taking Advantage of Flexibility Offered by MARSSIM 4:00 pm Adjourn ENCLOSURE 2