Notice of Violation from Insp on 780925-29
ML20204D198
Person / Time
Site: Limerick  
Issue date: 10/31/1978
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20204D196 List:
References
50-352-78-07, 50-352-78-7, 50-353-78-04, 50-353-78-4, NUDOCS 7812110302
Download: ML20204D198 (1)


Text

I 1

APPENDIX A i.

NOTICE OF VIOLATION Philadelphia Electric Company Docket No. 50-352 This refers to the inspection conoucted by repre'sentatives of the Regio'n I (Philadelphia) office at the Limerick Generating Station, Unit 1, Limerick, Pennsylvania, of activities authorized by NRC Ll cense No. CPPR-106.

i During this inspection, conducted on September 25-2g,1978, the following-apparent item of noncompliance was identified.

10 CFR bO, Appendix B, Criterion V, states in part, that:

Activities affecting quality shall be prescribed by documented instructions, pro-cedures, or drawings... and shall be accomplished in accordance with these instructions, procedures, or drawings."

The Limerick PSAR, Appendix D Quality Assurance Program, paragraph 6.4, states, in part, that: '"Bechtel Construction Department... is responsi-ble for construction of the plant to approved engineering specifications, drawings and procedures..."

The Peabody Testing Inc., a centractor to Bechtel, utili:es non-destructive examination procedure titled " Liquid Penetrant Inspection of' Welds and Components," IPPT-340-39-02, Amendment i.

2, which states, in part, in paragraph 5.5.3, that:

... final interpretation shall be made a minimum of seven minutes and no later than thirty.

i I

minutes after the developer is applied."

28, 1978, during the liquid penetrant Contrary to the above, on September test of weld joint HSC-182-1/0-P450, the licensee's contractor technician made interpretations before the seven minute developer dwell time had elap l

This item is an infraction.