Forwards Safeguards Event Rept 99-001-00,providing 30 Day Written Rept Re Compromise of Safeguards Info in That Old Rev of LGS PSP Was Discovered on Hard Drive of self- Contained Computer Sys within Security Ofc Area
ML20204D043
Person / Time
Site: Limerick 
Issue date: 03/16/1999
From: Gallagher M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20204D048 List:
References
NUDOCS 9903240072
Download: ML20204D043 (1)


Text

~.

~

8

,8 Michrl P. Gallaghe,, P.E.

Plant Manager timerick Generating Station PECO NUCLEAR reco rnero< cornoenv Lmenck Generating Station A Unit of PECO Energy PO Box 2300 Sanatoga, PA 194644920 610 718 2000 10CFR73.71 March 16, 1999 Docket Nos. 50-352 50-353 License Nos. NPF-39 NFP-85 U.S.

Nuclear Regulatory Commission Attn.:

Document Control Desk Washington, DC 20555 l

SUBJECT:

Safeguards Event Report Limerick Generating Station - Units 1 and 2 l

This Safeguards Event Report provides the 30-day written follow-up report regarding the compromise of safeguards information in that an old revision of the Limerick l

Geherating Station (LGS) Physical Security Plan was discovered on the hard drive of a self-contained computer system within the Security office Area.

Reference:

Docket Nos. 50-352,50-353 Report Number:

1-99-001 Revision Number:

00 Event Date:

February 17, 1999 Report Date:

March 16, 1999 Facility:

Limerick Generating Station l

P.O.

Box 2300, Sanatoga, PA 19164 This Safeguards Event Report is being submitted pursuant to the requirements of 10CFR73.71(b).

Sincerely, cc:

H.

J. Miller, Administrator Region I, USNRC A. L.

Burritt, USNBC Senior Resident Inspector, LGS g

hnL I

')

'Annnn 9903240072 990316 F

PDR ADOCK 05000352d/

8 POR, a