ML20204B653

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 870202-13
ML20204B653
Person / Time
Site: Rancho Seco
Issue date: 03/20/1987
From: Wenslawski F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML20204B636 List:
References
50-312-87-05, 50-312-87-5, NUDOCS 8703250121
Download: ML20204B653 (2)


Text

__

s APPENDIX A NOTICE OF VIOLATION Rancho Seco Nuclear. Generating Station License No. OPR-54 14440 Twin Cities Road Docket No. 50-312 Hearld, California 95638-9799 As a result of the inspection conducted during the period of February 2-24, 1987, and in accordance with NRC Enforcement Policy 10 CFR, Part 2, Appendix C, the following violations were identified:

A.

Technical Specifications, Section 4.22.1, requires that the release rate of radioactive materials, other than noble gases, in gaseous effluents shall be determined by obtaining representative samples and performing the analysis in accordance with the sampling and analysis program specified in Table 4.22-1.

Table 4.22-1 requires that releases of the types listed as A, B, and C be analyzed for Sr-89 and Sr-90 on a quarterly basis.

Contrary to the above, the licensee has not performed the Sr-89 and Sr-90 analysis since 1978.

This is a Severity Level IV Violation (Supplement 1).

B.

10 CFR Part 71.5(a) requires:

"Each licensee who transports licensed material outside the confines of the plant or other place of use or who delivers licensed material to a carrier for transport, shall comply with the applicable requirements of the regulations appropriate to the mode of transport of 00T in 49 CFR Parts 170 through 178."

49 CFR Part 172.403 requires that a Radioactive Yellow III label must be affixed to each package which measures more than 50 millirem per hour on the package surface or exceeds a transport index of 1.0.

Contrary to the above, on Septepiber 25, 1986, radioactive material was shipped to Babcock and Wilcox in package number 72193 by way of a common carrier having a transport index of 1.8 and did not bear a Yellow III label.

6 This is a Severity Level IV Violation (Supplement V),

With respect to Item A, pursuant to the provisions of 10 CFR 2.201, no response is necessary in view of the timely manner in which corrective actions were taken to resolve the item. With respect to Item 8, Sacramento Municipal Utility District is hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation addressing the alleged violation and including:

(1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; (3) the date when full compliance will be achievad.

l 0703200121 070320 PDR ADOCK 05000312 G

PDR

Consideration may be given to extending your response time for good cause shown.

MAR 201987 yfg,f/gj

/-

Dated F. Ai Wenslawski, Chief Emergency Preparedness and Radiological Protection Branch

-